SE&A-3 Low Voltage brochure 2/9/00 10:39 AM Page 3 In today's high-tech m anufacturing w orld,profitability can be greatly im pacted by equipm ent shutdow ns due to electrical faults.Industrial m anufac- turers dem and solutions that m inim ize equipm ent dow ntim e and optim ize product efficiency. Research show s that pow erfailures cost U .S.industry m ore than $25 billion a yearin dow ntim e.Recognizing the need forreliable and cost efficient solu- tions,Siem ens Energy & Autom ation provides state of the art sw itchgearto elim inate dow ntim e concerns in process industries and those w here back-up pow ersupply is critical. Advanced SwitchgearSolutions forProcess Industries critical power SE&A-3 Low Voltage brochure 2/9/00 10:39 AM Page 1 High Resistance Grounding System Siem ens Energy & Autom ation offers high resistance grounding equipm ent specifically designed foruse in industri- al environm ents w here continuous processes are used and equipm ent shutdow ns are not an option.In these applications,the userprefers to m aintain service during ground fault conditions w hile providing alarm indications that w ill lead to quick location and correction of the fault or a planned and orderly shutdow n of the process. Siem ens low -voltage neutral grounding system s w ith pulsing ground fault detection circuitry are provided in tw o variations: a free standing unit orone included in the Siem ens 480V m etal enclosed low -voltage pow ercircuit breakersw itchgear. Siemens low-voltage neutral grounding systems perform the following functions: I Provides a high resistance ground connection fora 480-volt three- phase pow ersystem . This provides the continuity of service associated w ith ungrounded system s,w hile reducing the high transient over-voltages associated w ith them . I Provides an im m ediate indication of the first system ground. I A llow s the system to operate until the fault is located and corrected. I Provides a m ethod forlocating the fault quickly,before a second fault occurs.It should be noted that high resistance grounding system s cannot serve phase to neutral loads. SE&A-3 Low Voltage brochure 2/9/00 10:41 AM Page 4 v o l t a g e
c o n t r o l General Description D uring norm al conditions,w ith no ground fault on the system ,no voltage appears across the grounding resistors. A w hite indicating light on the panel indicates that control voltage is available and that the system is turned on. W hen a ground fault occurs,the resistors lim it the ground current to a low value,adjustable betw een 0.92 and 3.69 am peres.The voltage coil of the m eterrelay w ill sense the voltage across the resistors during a ground fault condition.In orderto lim it the voltage present on the instrum ent door, it is sensed across half of the resist- ance.W hen a ground fault occurs,an auxiliary relay,operated by the m eter relay,has contacts that illum inate a red indicating lam p and m ay be used for rem ote indication and annunciation. The red light and rem ote signal rem ain until the condition is cleared and the system is reset. To trace the ground fault,the operator turns the pulse sw itch on.This initiates the cycle tim eralternately energizing and de-energizing a contactorthat parallels a second resistorw ith the grounding resistor.The result is a periodic fluctuation in the m agnitude of the ground current,doubling its value.A green indicating lam p follow s the pulse. 480Vor600VDelta System SE&A-3 Low Voltage brochure 2/9/00 10:42 AM Page 5 A clam p-on am m eteris then used to first see the signature of the pulse at the loop in the resistorgrounding w ire, and then trace the fluctuations in ground current through the system to the point of fault.The signature current fluctuation observed on a portable clam p-on am m eterstops once the ground fault is betw een the am m eter and the neutral resistor.A current transform erand panel-m ounted am m eterw ill allow the operatorto determ ine the current fluctuations on the system . A fterthe ground point has been located and rem oved from the system , the operatorturns the pulse sw itch off, de-energizing the pulse cycle tim er circuit,and depresses the reset button to reset the fault indicating light and alarm contacts. Taps are provided on the resistors to adjust the m agnitude of the ground current in the range of 0.92 to 3.69A , depending on the size of the system , so that the current through the resistor to a ground fault w ill be slightly greater than the system s natural capacitance charging current.Both the grounding resistorand pulsing resistorshould be set to the sam e value. f u n c t i o n a l i t y 480Vor600VWYE System SE&A-3 Low Voltage brochure 2/9/00 10:42 AM Page 6 Siem ens Energy & Autom ation,Inc. ForN earest Sales O ffice Low Voltage Sw itchgearD ivision 1.800.964.4114 7000 Siem ens Road www.sea.siemens.com/ W endell,N C 27591 sales/salesoffices.html Siem ens Energy & Autom ation,Inc. O rderN o.LVIM -00101 Siem ens is registered tradem ark of Siem ens AG . 70M 0200TD Printed in U .S.A . Specifications are subject to change w ithout notice. Standard Equipment List 480V or 600V WYE or Delta Typical Dimensions A 1 B 2 90.00" 30.00" 30.00" SHIPPINGGROUP #1 20.94" 1.06" 2.5" 3.5" 4.0" 18.75" 3.0" SPACE AVAILABLE IN TOP OR BOTTOM OF CUBICLE FOR CUSTOMERS CABLE ENTRY. CUSTOMER TODRILL TOP PLATE TOSUIT TOP FEED CABLES. LOCATION OF HOLES IN FLOOR FOR CUSTOMERS ANCHOR BOLTS REFER TOBOLTINGARRANGEMENT. Equipment included in Standard 480V or 600V WYE System with System Neutral available (one of each) I M eterrelay (M R ) I N orm alw hite indicating light (W ) I G round Faultred indicating light (R) I Pulsinggreen pulsing indicating light (G ) I Resetpush button (PB /R ESET) I Testpush button (PB /TEST) I O n - O ff sw itch (System Sw itch) I O n - O ff sw itch (Pulse Sw itch) I Instruction plate on door I Repeat cycle tim er,set to produce approx.30 current pulses per m inute (RC T) I N eutral grounding resistor assem bly (H R ED ,H R EE) I Pulse resistorassem bly (H R EB,H R EC ) I Test resistorassem bly (H R EA ) I Relay forrepeat cycle tim er(PR ) I A larm relay,w ith extra interlocks forrem ote alarm (59X) I C ontrol Pow erTransform er (C PT) N ote 1 I Portable clam p on am m eter (optional) I N eutral current transform er (C T) I N eutral am m eter(A M ) Note 1: When included in a switchgear line up, the control power is common with the switchgear. Equipment included in Standard 480V or 600V Delta System without System Neutral available Sam e as W YE system w ith the addition of: I 3 G rounding transform ers for generating a neutral (C PT) Stand-alone NEMA 1 enclosure with Neutral resistors . . . 240V systemvoltage 480V systemvoltage 600V systemvoltage DELTA WYE Price & OrderingGuide Description HRG LIST PRICE $13,500 240 480 600 D $1,750 Y NC Accessory: Portable Clamp-on Ammeter $3,975 FrontView Front of Plan View (Weight 950 lbs.) SE&A-3 Low Voltage brochure 2/9/00 10:39 AM Page 2