You are on page 1of 111

Schneider busway

from 800 to 6000 A

I-LINE II
Catalogue 2008

Contents

Introduction

In decentralised distribution, Schneider busway hits the high note!


With Schneider busway, you play all the right notes!
Schneider busway, in total harmony with the environment!
Schneider busway, fortissimo throughout the range!
Schneider busway, a display of advantages!
Schneider busway, every one to their music!
Schneider busway, hits the right notes!
With the Schneider busway tools and services, let us compose your project!

3
4
6
8
10
12
16
17

Presentation and description

19

Panorama of Schneider busway range


General
Straight lengths
Fittings
Supports and fixings
Special fittings
Plug-in units

20
26
28
29
31
32
33

Catalogue numbers and dimensions

35

Catalogue number coding

36

I-LINE II Copper Busway (CFC)


Straight lengths
Straight length components
Elbows
Flanged ends
Cable Tap Box
Supports and fixings

38
39
41
51
54
55

I-LINE II Copper Contact Busway (BFC)


Straight lengths
Straight length components
Elbows
Flanged ends
Cable Tap Box
Supports and fixings

58
59
61
66
69
70

Plug-in units

72

Design guide

81

Characteristics
Designing with I-LINE II busbar trunking system
Harmonic currents
Fire resistance
Measurements and metering
Direct current

82
84
88
90
92
94


Installation guide

95

Layout advice
Horizontal distribution
Rising mains
Reception, handling and storage
Testing and Commissioning
Maintenance

Schneider Electric

96
99
100
102
104
108

K9CE01010
2

Schneider Electric

PD202382

Schneider busway on its second world tour


More than 50 years of experience, with hundreds of thousands of installations in
operation throughout the world.
Full KEMA type test certification (IEC60439) for each and every ampere rating
of busway.

A total coordination with the


Schneider Electric system

More than 50,000 km of Schneider busbar trunking has been


sold around the world.

Busway is a part of a comprehensive offering of Schneider Electric products


designed to operate together. This concept covers all low and medium
voltage electrical distribution components. The result is an optimised electrical
installation with even higher performance through full electrical, mechanical and
communication compatibility.
With the new range, you get a complete, tested distribution solution that
complies with standards. It is perfectly suited to traditional applications (factories,
warehouses, etc.) and to the distribution of electrical power from the incoming
transformer on through to all types of loads in offices, commercial premises,
laboratories, etc.

Schneider Busway Factories


Dijon Factory was set up in 1972, manufacturing Canalis Busbar trunking system,
ISO 9001 and ISO 14001 certified.

Canlis Factory, Dijon, France

I-LINE busbar trunking system was first introduced by Square D in 1961 in its
production facility in Oxford, Ohio U.S.A. As one of the major brands of the
Schneider Electric, Square D has acquired worldwide recognition in a variety of
busway applications.

Square D facility in Oxford, Ohio U.S.A. is an ISO 9001 and


ISO 14001 registered busbar trunking manufacturing facility.

Schneider Busway Guangzhou was initially set up by Square D, USA in 1997, and
now is a professional busbar trunking manufacturer, product including I-LINE II and
Canalis series, mainly supplying to the Asia Pacific and Middle East market.

Schneider Buway (Guangzhou) Ltd. is certified having ISO


9001 quality management system, ISO 14001 environment
management system and OHSAS 18001 occupational health
and safety management system.

K9CE01010

Schneider Electric

Introduction

In decentralised distribution,
Schneider busway hits the high note!

Introduction

With Schneider busway, you play


all the right notes!

Distribution systems

Schneider Electric offers different distribution systems to fit your operating needs.

Centralised distribution
For all continuous processes:
cement plants,
oil and gas,
petrochemicals,
steel,
paper, etc.
Centralised distribution offers:
continuity of service,
combined distribution of power, control and monitoring circuits,
supervision, etc.
Our solutions:
Prisma Plus and Okken switchboards.

Decentralised distribution
For manufacturing industries:
mechanical,
textiles,
lumber
injection moulding,
electronics,
pharmaceuticals,
livestock, etc.
Decentralised distribution lets you:
design installations without layout details,
upgrade without shutting down production,
get systems up and running sooner thanks to faster installation,
generate savings depending on the number of loads.
Our solutions:
Prisma Plus switchboards,
Schneider busbar trunking.

Combined distribution
Where the advantages of both centralised and decentralised distribution are
required.
Commercial and service buildings:
offices,
stores,
hospitals,
exhibition halls, etc.
Infrastructures:
airports,
telecommunications,
internet data centres,
tunnels, etc.
Industrial facilities:
pharmaceuticals,
food processing, etc.
Our solutions:
Prisma Plus and Okken switchboards,
Schneider busbar trunking.

Schneider Electric

K9CE01020

The Schneider busway


decentralised distribution
concept

Electrical power available at all points, throughout the


installation.
Exclusive features of the Schneider Electric system

Total coordination of the Schneider Electric system provides maximum safety of life
and property, continuity of service, upgradeability and ease of installation.
Product characteristics are checked by calculations and tests carried out in our
laboratories and certified in independent international recognized laboratories.

A competitive installation.

Simplicity, upgradeability, safety and continuity of service and operation.

DD205658

Savings start with installation


With plug-in points, Schneider busbar trunking reduces installation costs.
Given the low cost of adding new circuits, savings increase as the number of loads
increases, a natural consequence of the growth of your business.

Schneider busbar trunking

Upgradeable during operation

In decentralised distribution, evolving operating requirements and costs are


integrated right from the start.
The addition, relocation or replacement of load equipment can be carried out
quickly, without de-energising the supply trunking or shutting down operation,
The cost of making such changes is greatly reduced:
loads are located close to supply points,
plug-in points are always available,
plug-in units can be reused or new ones added quickly for load relocation or
replacement needs.

Reusable in the event of major changes


When making major modifications to your installation, the existing trunking can be
easily dismantled and reused.

K9CE01020

Schneider Electric

Introduction

With Schneider busway, you play


all the right notes!

Introduction

Schneider busway, in total


harmony with the environment!

Safety of life and property

With Schneider Busway, no toxic emission in case of fire

The busbar trunking has a low combustible load. Its construction uses very little
consumable material and is halogen free.
In the event of a fire, the busbar trunking does not emit any gas or toxic smoke.
The busbar trunking helps prevent the propagation of a fire through partition walls
and floors.
Halogen-sensitive applications
Public buildings (infrastructures, hospitals, schools, etc.),
Buildings with evacuation difficulties (high-rises, ships, etc.) and service-activity
buildings,
Sensitive processes (production of electronic components, etc.).

Schneider Busway contains no PVCs

Example:
Consequences of a fire in a 100 m2 office with
electrical distribution by cables.
200 kg of cables (i.e. 20 kg of PVC) produces:
4400 m3 of smoke,
7.5 m3 of hydrochloric acid,
3.7 kg of corroded steel.

Health

When PVCs burn, they produce large amounts of smoke that can be a serious
safety hazard.
Reduced visibility:
risk of panic,
complicates rescue work,
Smoke toxicity:
hydrogen chloride gas (highly toxic),
carbon monoxide (danger of asphyxiation).

Schneider Busway reduces the risk of exposure to


electromagnetic fields

According to the WHO (World Health Organisation), exposure to electromagnetic


fields can be a health hazard starting at levels as low as 0.2 micro-Teslas and
could represent a long-term risk of cancer. Some countries have created standards
that stipulate limits
All electrical conductors generate magnetic fields proportional to the distance
between them. The design of Schneider busbar trunking with tightly spaced
conductors in a metal enclosure helps to considerably reduce radiated
electromagnetic fields.
The electromagnetic field characteristics of Schneider busbar trunking are welldefined and measurements show that they are far below potentially dangerous
levels.

Schneider Electric

K9CE01030

Environment

Schneider Busway is fully recyclable

Schneider Busway busbar trunking can be reused.


Schneider Busway busbar trunking is designed for a long service life and can
easily be dismantled, cleaned and reused.
All packaging materials can be recycled (cardboard or recyclable polyethylene
film).
All Schneider Busway products are designed for safe end-of-life recycling. PVC,
on the other hand, requires neutralisation of the hydrochloric acid produced using
lime and generates dioxins that are extremely toxic.

Schneider Busway helps conserve natural resources

Example:
1 kg of PVC generates 1 kg of waste.

Conservation of natural
resources

The depletion of raw materials (copper, plastics, etc.) is one of our ongoing
concerns.
For this reason, we have optimised the used of all materials used to make our
busbar trunking:
Reduction of dangerous or polluting materials.
Reduction in the weight of insulating materials,
Reduction in the use of plastics for improved fire performance: less energy
released during combustion, thereby limiting propagation and facilitating extinction
(lower calorific value).

Schneider Busway reduces your line losses by 20 %


Schneider Busway divides your consumption of plastic by a
factor of four

The cost of an electrical installation includes the initial investment for the
equipment and its installation, the cost of maintenance and the cost of energy
losses during operation.
The concept of decentralised distribution is a way to merge all the circuits in one
and thus to reduce to the maximum the low cross-section lengths and the weight of
insulating materials.

Example:

34m of 250A Schneider busbar trunking eqipped with 7 sets of 25A load.

K9CE01030

Schneider Electric

Introduction

Schneider busway, in total


harmony with the environment!

Introduction

PD202384

Schneider busway, fortissimo


throughout the range!

1
2

Application
1. Transformer/ Switchboard connection
2. Horizontal distribution, from the substation to the loads in workshop
3. Vertical distribution, from the substation to the loads of each high rise floor
4. Lighting application, in Park place, supermarket, exhibition center, metro ect.

Schneider Electric

K9CE01040

Introduction

Schneider busway, fortissimo


throughout the range!

Transformer/ Switchboard connection

Horizontal distribution

Vertical distribution

K9CE01040

Lighting application

Schneider Electric

Introduction

Schneider busway, a display of


advantages!

A compact solution

The compact size of Schneider busway means it takes up very little space in the
building:
used as a rising main, it takes up only a minimum of space,
used for horizontal distribution, it fits easily into the buildings structure (false
floors, false ceilings, service shafts, etc).
Changes in direction have been designed to optimise the space taken up,
contrary to an equivalent installation using cables which requires large bending
radii.
Tap-off units, complete with protective devices, are fitted along the entire length
of the busbar trunking thus reducing the floor area taken up by the electrical
distribution switchboards.

A simple and economical


system

The design study is easy to perform as it does not require a detailed layout of
each load. Equipment choice is pre-determined and optimised.
Installing the busbar trunking requires 2 or 3 people only, for a time equivalent
to that for installing cableways. The time normally needed for laying cables is
therefore saved.
Connection to the MV/LV substation is made using a quick fitting joint block. The
plug-in units can be prepared in the workshop thus reducing on-site time. Their
connection to the busbar trunking is done in a single plugging-in operation.For
those ratings more than 500A, it is done by bolt-on operation.
Installing busbar trunking lengths can be done as and when building work
progresses, thus optimising on-site work and allowing possible unexpected events
to be anticipated in advance.
It is also important to note that busbar trunking is a factory tested solution,
meaning the time needed for inspecting connections is reduced (visual inspection
of tightening torque).

10

Schneider Electric

K9CE02010

Complete safety

Busbar trunking temperature rise and short-circuit withstand are known and
independent of the installation. Coordination of the Schneider Electric system
results in complete control of the electrical network.
Installation standards IEC 60 364 chapter 5.523.6 stipulate that above 4 parallel
cables, it is preferable to use busbar trunking. Paralleling many cables leads to
uneven distribution of currents and the risk of abnormal temperature rise.
The busbar trunking and plug-in units are designed to guarantee the safety of
personnel and equipment:
Fully silver-plated cooper contact solution.
bolted connections with tightening torque guaranteed by torque nuts.
foolproof system to avoid the risk of assembly errors.

Its metal enclosure and high protection degree protect the busbar trunking from all
external aggressions (corrosion, rodents, etc).

Seismic Compliance

The complete standard offer of I-Line and Canalis busway is certified for Zone 4
seismic conditions as witness and approved by mechanical and dynamic tests, at
EERTC (Earthquake Engineering Research & Test Centre) in China, as well as
electrical verification test performed by CEST under IECEE CB scheme.
For projects under seismic conditions, consult your local Schneider office to
provide you with more information in particular on hangers and supports.

Operating continuity

When working on the electrical installation, the busbar trunking provides immediate
readability of the electrical circuit thus allowing the appropriate zone to be quickly
identified.
Plug-in units(<40A) can be plugged-in and out without the need for a shutdown;
service continuity is thus irreproachable.
The quality of the electrical contacts guarantees maintenance free operating
continuity.

A large range of plug-in units


All I-LINE plug-in units are compatible with I-LINE II busbar trunking system,
regardless whether they bear MCCB or fusible switch.
Plug-in unit with Merlin Gerlins MCCB, ampere rating from 15A to 1000A
Plug-in unit with Square Ds MCCB, ampere rating from 15A to 1600A
Plug-in with fusible switch, ampere rating from 30A to 1600A

K9CE02010

Schneider Electric

11

Introduction

Schneider busway, a display of


advantages!

Introduction

Schneider busway, everyone to


their music!

Office and Hotel buildings

Key points
Fire barrier.
Halogen free.
Small size.
Operating continuity.

Key projects
Pentronas Towers (Malaysia)
Hong Kong International Financial Center (Hong
Kong)
Shanghai Jin Mao Building (China)
Emirates Palace (UAE)
Grand Indonesia Building (Indonesia)
Dubai International Finance Center (UAE)
Al Shira'a Tower (Kuwait)
Beverly Hill Tower (Qatar)
Al Safwa Tower (Saudi Arabia)
Robinson Cybergate Center Tower (Philippines)
Mita Koyamacho High-rise Apartment (Japan)
International Commerce Centre (Hongkong)
Congresss Conference Building (Egypt)

......

Shopping centres and


Exhibition centres

Key points
Halogen free.
Distribution and metering.
Able to be evolved.
Sprinklers.

Key projects
Carrefour supermarket(World wide)
Guangzhou International Exhibition
Centre(China)
Convention & Exhibition Centre(Hong Kong)
Asia World Expo(Hong Kong)
Central World Mall(Thailand)
Siam paragon (Thailand)
Abu Dhabi National Exhibition Center( UAE)
Mall of Arabia (Saudi Arabia)
Melbourne Convention Centre (Australia)
Mall of the Emirates (UAE)
National Convention Centre (Vietnam)
Queensgate shopping Mall (New Zealand)
National Olympic Stadium (Guangzhou, China)
Panda Distribution Facility (Saudi Arbia)
Las Vegas Sands (Macau)

......

12

Schneider Electric

K9CE02020

Industry buildings

Key points
Operating continuity.

Introduction

Schneider busway, everyone to


their music!

Key projects
General Motors (World wide)

Able to be evolved.

Hitachi Semiconductor manufacturing


(China)

Low voltage drops.

Chartered Semiconductor manufacturing


(Singapore)

Network readability.

Maruti Suzuki (India)


Jabil Plant (India)
Nikon Factory (Thailand)
Intel Plant (Malaysia)
Infineon Plant (Malaysia)
Bosch (Korea)
Seagate Factory (Singapore)
ST Microelectronics (Singapore)
Ansell Lanka (PVT) Limited (Sri Lanka)

......

Data centers and Banks

Key points
Operating continuity.
High tap-off density.
Able to be evolved.
Network compactness
and readability.

Key projects
Bank of China Tower (Hongkong)
China Construction Bank (China)
Citibank Hongkong (Hong Kong)
Maybank (Malaysia)
Commercial Bank (Qatar)
Saudi Telecom Company (Saudi
Arabia)
Bharti data Centre (India)
HSBC Bank HQ (Babrain)

......

K9CE02020

Schneider Electric

13

PD202391

Energy

Key points

Key projects

Operating continuity.

Three Gorges Power


Station(China)

Able to be evolved.

Wind Farm(China)

Low voltage drops.

ExxonMobil Chemical
plant(Malaysia)

Network readability.

Hysco Steel(India)
Shell Chemical plant (Malaysia)
Petro Rabigh(Saudi Arabia)

......

Airport

Key points
Halogen free.
Distribution and metering.
Able to be evolved.

PD202387

Introduction

Schneider Busway, everyone to


their music!

Sprinklers.

Key projects
Beijing Capital New International
Airport(China)
Suvarnabhumi Airport (Thailand)

Tan Son Nhat Airport(Vietnam)


India Ahmedabad Airport(Inida)
Cairo Airport(Egypt)
Dubai Airport(UAE)
Jebel Ail Airport(UAE)

......

14

Schneider Electric

K9CE02020

PD395077-68

Hospital

Key points

Key projects

Fire barrier.

The first affiliated Hospital,


Guangzhou(China)

Halogen free.

Angkor International
Hospital(Thailand)

Small size.
Operating continuity.

Introduction

Schneider Busway, everyone to


their music!

Al-Maidan Hospital(Kuwait)
Beijing 301 Hospital(China)
Mina Hosptital (Saudi Arabia)
Dammam Hospital (Saudi Arabia)

......

Metro

Key points
Halogen free.
Distribution and metering.
Able to be evolved.
Sprinklers.

K9CE02020

Schneider Electric

Key projects
Guangzhou Metro(China)
Singapore Metro
Madrid Metro (Spain)
London Metro (UK)

......

15

Introduction

Schneider busway, hits the right


notes!

Quality - Accreditations

IEC Certification ASTA / ASEFA /KEMA / IECEE / CNAL


UL Certification
CCC approved
ISO 9001, ISO14001
OHS18001
Six Sigma Program

16

Schneider Electric

K9CE02040

Work-out your
solution together

Our teams are available to provide customers with technical assistance throughout
the installation of their projects.

PD202396

Design of electrical distribution architectures:


design of decentralised transport and distribution systems,
technical and financial optimisation of busbar trunking design projects,
transformer/switchboard link,
installation coordination and discrimination.
Full installation drawings:
3D drawings with corresponding parts lists,
2D drawing with dimensions,
detailed connection drawings.
Site supervision and commissioning assistance.
Training for designers and contractors.

Technical
support

Project
launch

BRASS
drawing

After-sales
service
Autocad
drawing
On-site
instruction
and
installation

Production
Project
management

K9CE02040

Schneider Electric

17

Introduction

With the Schneider busway tools


and services, let us compose your
project!

Introduction

With the Schneider busway tools


and services, let us compose your
project!

BRASS gives you all the


help you need

Schneider Electric offers a comprehensive design software.


The BRASS software, edited by Schneider Electric, was developed to help you
design I-LINE II busbar trunking runs.
BRASS, a comprehensive tool
The BRASS software allows you to quickly design the best layout for your project.
It allows:
the material needed to be easily chosen
a list of catalogue numbers and their exact quantities to be defined

State-of-the-art software

The advanced BRASS design software enables you design from the routing to
component detail in a more accurate, convenient and quicker way.
Horizontal distribution

Vertical distribution

18

Schneider Electric

K9CE02040

Presentation and description

Presentation

20

I-LINE II from 800 to 6000 A

24

Description

26

General

26

Straight lengths

28

Fittings

29

Supports and fixings

31

Special fittings

32

Plug-in units

33

K9CE02040

Schneider Electric

20
20
22

Description

Presentation

Panorama of Schneider Busway range


Lighting distribution
Power distribution

19

Presentation

Panorama of Schneider Busway range


Lighting distribution

Canalis

Range

Canalis KDP

Presentation

Run components
Degree of protection

IP55

Number of circuits

Rating

20 A

Tap-off intervals

1200 - 1350 - 1500 - 2400 - 2700 and 3000 mm

Standard lengths

24 and 192 meters

Finish

Maximum distance between fixing points

0,70 meter

KDP-KBA-KBB tap-off units

Rating

20

10 and 16 A

Schneider Electric

K9CE11000

Presentation

Panorama of Schneider Busway range


Lighting distribution

Canalis

Canalis KBB

IP55

IP55

1 or 2

25 and 40 A

25 and 40 A

500 - 1000 and 1500 mm

500 and 1000 mm

2 and 3 meters

2 and 3 meters

Galvanised steel

Galvanised steel

3 meters

5 meters

10 and 16 A

10 and 16 A

K9CE11000

Schneider Electric

Presentation

Canalis KBA

21

Presentation

Panorama of Schneider Busway range


Power distribution

Canalis

Canalis KS

Canalis KS rising mains

Degree of protection

IP52/54

IP52/54

Polarity

3L + N + PE

3L + N + PE

Rating

100, 160, 250, 400, 500, 630, 800

100, 160, 250, 400, 500, 630, 800

Tap-off intervals

1000 mm on each face

500 mm

Standard lengths

3 and 5 meters

Defined by the floor pitch

Finish

White RAL 9001

White RAL 9001

Maximum distance between fixing points

3 meters

Defined by the floor pitch

25 to 400 A

25 to 400 A

Presentation

Range

Run components

Tap-off units

Rating

Plug-in
Bolt-on

22

Schneider Electric

K9CE11000

Presentation

Panorama of Schneider Busway range


Power distribution

I-LINE II

I-LINE II Copper contact busway

IP40 / 54 / 55 / 65 / 66

IP40 / 41 / 54 / 65 / 66

3L + N+PE / 3L+ PE ;

3L + N+PE / 3L+ PE ;

800 - 6000A

800 - 5000A

610mm/1220mm

610mm/1220mm

10 Feet

10 Feet

ANSI 49

ANSI 49

10Ft

10Ft

15 to 500 A

15 to 500 A

630A to 1600 A

630A to 1600 A

Presentation

I-LINE II Copper busway

K9CE11000

Schneider Electric

23

Presentation

I-LINE II from 800 to 6000 A


High Power transport and
distribution

I-LINE II
Plug-in units

Elbow Fittings

Rating: 12 ratings are available, from


800A to 6000A
Standard length: 10 feet, 6 feet, 4 feet
None-standard length: minimum length
406mm

All I-LINE plug-in units are compatible with


I-LINE II busbar trunking system
Category: plug-in unit with MCCB, plug-in
unit with fusible switch
Plug-in unit with Merlin Gerlins MCCB,
ampere rating from 15A to 1000A
Plug-in unit with Square Ds MCCB,
ampere rating from 15A to 1600A
Plug-in unit with fusible switch, ampere
rating from 30A to 1600A

Standard elbow:
Flatwise elbow
Edgewise elbow
Non-standard elbow:
Double elbow
Offset elbow
Elbow plus flanged end
Elbow in special angle
Elbow in special length

Presentation

Run sections

24

Schneider Electric

K9CE11500

Presentation

I-LINE II from 800 to 6000 A


High Power transport and
distribution

I-LINE II
Fixing supports

Supply connections allow the


busbar trunking to be connected to the
switchboards busbar or to the transformer.
Flanged end
Qwik Flanged end
cable connection, transport current
between cable and busbar trunking.
End cable tap box
Center cable tap box

Vertical support
Fix hanger
Spring hanger
Horizontal support
Flatwise hanger
Edgewise hanger

Presentation

Connection fittings

K9CE11500

Schneider Electric

25

Description

General

I-LINE II
The I-LINE II busbar trunking is intended for high power distribution and transport
in industrial, commercial and tertiary buildings.
Assembly of prefabricated sections that adapt to all run configurations.

Straight Length
12 ratings are available, from 800A to 6000A
Silver plated copper contact
Conductors full-length insulated using Mylar film, class B, 130C
Available polarities: 3L +PE, 3L +N+PE
Maximum rated voltage: 1000 Volts
Insulation voltage: 1000 Volts

Compact Size, Sandwich Structure, totally enclosed housing


Description

Universal Installation, no need to consider de-rating factor, regardless of the


mounting position.
The accumulation of dirt on exposed bus bars and possibility of accidental
contact with bus bar are greatly reduced.
No Chimney effect
Continuous air spaces inside I-line busway housing are closed off with special
barriers to help prevent the spread of smoke and gases in the event of a fire in
the area of the busway installation. This standard internal barrier allows busway to
extend through wall or floors without creating open space for a chimney effect fire
path.
Improve systems ventilation, satisfy higher ampere rating
Less space required for installation, investment saving

The I-LINE II busbar trunking is suitable for applications containing harmonics by


taking into account the appropriate derating factor. See Harmonic currents in the
Design guide.

Joint Pak
Joint-Pak is standard on I-LINE II system. It allows for quick removal of lengths
from the busbar trunking runs for load shifting or maintenance. It also can be
removed and relocated on the opposite end of the length for the last minutes job
changes
Single bolt connection makes installation faster
Belleville washer provides equal pressure across the complete joint contact area
to assure proper electrical contact
Double, Silver plated surface contact ensure a good current continuity.
Adjustable range: +/- 3mm

VIST-TITE Bolt

The double head design, introduced by Square D in 1967, allows the customer to
tighten the joint to the proper torque using a standard spanner. The outer head will
break off when the correct torque is achieved. A second bolt head remains to allow
for joint maintenance or busbar relocation. No need to purchase a replacement
bolt. For maintenance of the joint or when busway is relocated, the VISIT-TITE bolt
should be tightened to 70 lb-ft (95Nm) with a torque wrench

Housing
Electro-galvanized steel, better anti-corrosion.
Paint: Epoxy electrostatic powder finish
Color: ANSI 49 gray, special color are optional upon customers request.

26

Schneider Electric

K9CE12000

Description

General

I-LINE II
Earthing Bus
I-line II is furnished with the integral earthing bus as standard. The earthing bus
is the bus housing itself and completely encloses the bus sandwich. It is rated at
50% capacity. The earthing bus is Continuous bonding between top and bottom
bus.

Integral Earth Bus

Internal Earth Bus

Schneider believes an earthing conductor is extremely important, to provide the


maximum amount of protection for a distribution system in todays ever expanding
electrical systems. With our design, we have given the maximum amount of
protection in an economical package.

Conductor
Copper (Copper busway)

99.97% purity of copper


Silver plated copper in full length
minimize surface oxygenation, assure low surface contact resistance and low
voltage drop

Aluminum with copper contact (Copper contact busway)

Use silver-plated Bi-metal cladding on Aluminum conductor through high


current and high pressure.
Special process enabling molecular fusion of Copper and Aluminum through
the use of very high pressure and temperature.
All of connection zone are silver to silver.

Insulation
Two layers surrounding each bus bar
Class B, 130C, Vendor certified polyester film (DuPont Mylar)
Excellent dielectric performance
Over 40 years of application record without failure
Class F is optional upon request
Halogen free, safe in fire

Degree of Protection
Schneider offers the I-LINE II bus bar trunking system in a variety of housing
constructions to meet your application and needs.
Feeder type
Riser type
Plug-in type

K9CE12000

Schneider Electric

IP40-IP66
IP40-IP54
IP40-IP54

27

Description

Internal Aluminum/copper earthing bus is optional.

Description

Straight lengths

I-LINE II
Straight section
Feeder

Description

Transport the current without plug-in opening.


All straight lengths and fittings of feeder trunking are fully compatible, rating for
rating, with straight lengths of plug-in trunking.
12 ratings are available, from 800A to 6000A
Minimum length 406 mm
Polarity: 3L+N+PE, 3L+PE system
100% neutral capacity, 50% earth bus capacity

Riser
Plug-in opening (PIO) on one side, only 4, 6, 10ft available
Maximum 3 PIO for 10 feet riser element
N

Maximum 2 PIO for 6 feet riser element

Maximum 1 PIO for 4 feet riser element


N

Plug-in
Plug-in opening on both sides, only 4, 6, 10ft available
Maximum 6 PIO for 10 feet plug-in element
N

Maximum 4 PIO for 6 feet plug-in element


N

Maximum 2 PIO for 4 feet plug-in element


N

28

Schneider Electric

K9CE12000

Description

Fittings

I-LINE II
Simple changes of direction
Elbows - Types LF, LE and T
to go up or down, to turn right or left
Standard angle: 90
Special angles : 91- 179
type LF, flatwise elobw

Description

type LE, edgewise elobw

type T, flatwise tee

Changes of direction
Double elbows - Types OF, OE DR and DL
flat or edgewise, to move the run ais upwards, downwards, to the right or to the
left without having to bend the busbar trunking:
type OF, flatwise offset

type OE, edgewise offset

type DR, double right elbow

type DL, double left elbow

K9CE12000

Schneider Electric

29

Description

Fittings

I-LINE II
Connetions to swithboards and transformers
Flanged ends - Type FE

They allow the busbar trunking to be connected to a switchboards busbar, or to the


terminals of an transformer, generator set, etc.
They come complete with a mounting plate fitted:
either directly to the roof of the switchboard,
or via the intermediary of a protective cover.
Vertical or horizontal incoming busbar trunking.

Description

Type FE, standard flanged end

Type QF, qwik flanged end

type LEFE, edgewise elbow plus flanged end

type LFFE, flatwise elbow plus flanged end

Connetions to cable
Cable Tap Box

cable connection , transport current between cable and busbar trunking


type ETB, end cable tap box

type CTB, center cable tap box

30

Schneider Electric

K9CE12000

Description

Supports and fixings

I-LINE II
Horizontal Supports
The horizontal type hanger allow the busbar trunking to be fixed and ajusted along
its length, as well as absorbing its movements.
type HFF, flatwise hanger

Description

type HFE, edgewise hanger

Vertical Supports
Fix hanger
type HFV, fix hanger, for all ratings.

Spring hanger
The spring hanger has the following advantages:.
spring adjustment to ensure distribution of the load at each floor
avoids the transmission of buiding forces to the busbar trunking (expansion and
vibration)

type HFVS1, spring hanger

type HFVS2, spring hanger

type HFVS8, spring hanger

K9CE12000

Schneider Electric

31

Description

Special fittings

I-LINE II
Expansion Joint
An Expansion Fitting should be used under the following conditions:
whenever a busway run crosses a building expansion; when a long straight run of
busway does not contain any elbows or both ends of the run ar fixed.
No need for riser
38mm expansion allowable
more detail in page 99

Description

type EJ, absorb horizontal expansion

Reducer
Connect the high power and low power run
Best way to save investment
Standard reducer is non-fusible, reducer with fuse/MCCB is optional
type R

End closure
The end closure protects and insulates the conductor ends and is fitted to the last
section.

Connection accessory
Flexible link

for the connection between the conducting plates, to reduce the vibration from the
transformer.

Connection plates

the conductors of flanged ends are connected via connection plates to the
switchboard busbars.

32

Schneider Electric

K9CE12000

Description

Plug-in Units

I-LINE II
Product features of I-LINE II Plug-in Unit
Compatibility

All plug-in units are compatible with I-LINE II busbar trunking system, regardless
whether they bear MCCB or fusible switch.

Plug-in units are positioned along the busbar trunking length by notches in the
busbar trunking housing top which accept the mounting hooks of the plug-in unit.
This aligns the plug-in unit jaws with the plug-in opening. After the unit is positioned
on the busway, it is allowed to swing down into the plug-in opening where the plugin jaws make contact with the bus bars. This is accomplished in hook-swing.

Plug-in Jaws

The plug-in jaws contact to the bus bars directly with the silver plated cooper
contact. The contact surface is fully silver plated to ensure a proper contact force
and low contact resistance.

Earthing

Earthing established at first and switched off at last as to protect worker against
electrical contact shock.
All plug-in devices incorporate an earthing spring which cuts through the paint and
forms an equipment earth between the housing and the body of the device before
the phase jaws make contact with the busbars.

Interlock

30 A to 250 A plug-in devices are interlocked with the busway housing to prevent
installation or removal of the unit when the disconnect is turned ON.
All devices incorporates an interlock to prevent the door over the disconnect
from being opened when the unit is ON. This door interlock can be defeated from
outside the unit.

Operating handle

The side operating handle in the PIU makes the heavy duty switch more
convenient and safer. When the PIU is installed in the high position, you can easily
operate the PIU on the group by the side handle.

Protection function

Schneider Plug-in unit equipped with Schneider original protection unit, which
can provide complete overload protection, short circuit protection and earthing
malfunction protection. The maximum interrupting is 150KA.
Transparent shield over Line side parts - that means safety & visible

K9CE12000

Schneider Electric

33

Description

Plug-in device mounting

Description

Plug-in Units

I-LINE II
Category of I-LINE Plug-in Unit
Category of I-LINE Plug-in unit

Plug-in Unit with Merlin Gerlins MCCB, ampere rating from 15A to 1000A
Plug-in Unit with Square Ds MCCB, ampere rating from 15A to 1600A
Plug-in with Fusible Switch, ampere rating from 30A to 1600A

Plug-in Unit with Merlin Gerins MCCB


Plug-in Unit with Merlin Gerins MCCB

Description

Plug-in typePNS (15-250A), PBNS (350-500A)


Bolt-on typePTNS (630-1000A) (different for horizontal/vertical mounting)
Fitted with Compact NSEN/ NSES/ NSEH/ NSD / NSN / NSH / NSL(on request)
available for 3-pole and 4 pole configurations
available for earth leakage current protection (Vigi)

Plug-in Unit with Square Ds MCCB


Plug-in unit with Square D MCCB

Plug-in typePF(15-100A), PK(125-250A), PB(250-400A)


Bolt-on typePT(500-1600A) (different for horizontal/vertical mounting)
3 Poles only
PIU enclosure not interchangeable with PIU enclosure for MG breaker

Plug-in Unit with Square D fusible breaker


Plug-in unit Square D Fusible

Plug-in typePQ(30-200A), PS(125-250A), PBQ(250-400A)


Bolt-on typePTQ(500-1600A) (different for horizontal/vertical mounting)
equipped with UL/IEC fuse base

34

Schneider Electric

K9CE12000

Catalogue number coding

36

I-LINE II Copper Busway (CFC)




Straight lengths
Straight length components
Elbows
Double elbows
Offset elbows
Elbow plus flanged end
Internal Grounding Elbows
Flanged ends
Cable Tap Box
Supports and fixings

38
39
41
43
44
45
46
51
54
55

I-LINE II Copper Contact Busway (BFC)



Straight lengths
58
Straight length components
59
Elbows
61
Double elbows
63
offset
64
Elbow plus flanged end
65
Flanged ends
66
Cable Tap Box
69
Supports and fixings
70
Plug-in units
72

K9CE20000

Schneider Electric

35

Catalogue numbers
Dimensions

Catalogue numbers and


dimensions

Catalogue numbers and


dimensions

Catalogue-number coding

I-LINE II Copper Busway


Catalogue-number composition (I-LINE II Copper Busway)

Catalogue numbers
Dimensions

One letter designating the application.

Busbar material
Code
Copper
C
Type
Code
Feeder
F
Riser plug-in
R
Plug-in
P
Standard
Code
IEC
C
I-LINE II
2
Polarity
Code
3L + PE
3
3L + N + IGB (integral earth)
5
3L + N + ING (internal earth)
6
Rating
Code
800
08
1000
10
1250
12
1350
13
1600
16
2000
20
2500
25
3000
30
3200
32
4000
40
5000
50
6000
60
Type of PE
Code
AL
G
CU
GG
Dimension of component
Two letters identifying the type of component.
Type
Code
Generic Code
Elbow
EL
Flange End
FE
Qwik Flange End
QF
Expension Joint
EJ
End Tap Box
ETB
Center Tap Box
CTB
Flat Tee
T
Unfused Reducer
R
Discrete Code
Edgewise Elbow
LE
Flatwise Elbow
LF
Edgewise Offset Elbow
OE
Flatwise Offset Elbow
OF
Double Left Elbow
DL
Double Right Elbow
DR
Flange End Edgewise Elbow
LEFE
Flange End Flatwise Elbow
LFFE
Flange End - Double left
FEDL
Flange End - Double right
FEDR
Straight Length - Feeder/Plug-in/Riser
ST
Phase Transition
PT
Degree of Pretection
Code
IP40
-IP54
M54
IP55***
M55
IP65***
M65
IP66***
M66
*** Available for feeder system only

36

CC2GM

Catalogue Numbering System Generic v Discrete


Generic catalogue # describes all the features of busway (e.g. copper, ampere rating,
IP rating, 3/4 poles etc except length. Hence it is not for describing individual pieces
of busway but rather for quotation/contract/invoicing purposes. The unit is 1 piece (for
fittings) or 1 feet (straights)
Discrete catalogue # describes all the features of busway including length of the
individual pieces. With the discrete catalogue number itself, it tells the detailed length
of busway and is sufficient enough for production purposes. We also call this as BOM
(Bill of Materials)

Schneider Electric

K9CE20000

Catalogue numbers and


dimensions

Catalogue-number coding

I-LINE II Copper Contact Busway


Catalogue-number composition (I-LINE II Copper Contact Busway)
Busbar material
Code
Bimetal
B
Type
Code
Feeder
F
Riser plug-in
R
Plug-in
P
Standard
Code
IEC
C
I-LINE II
2
One digit indicating the trunking polarity
Polarity
Code
3L + PE
3
3L + N + IGB (integral earth)
5
Rating
Code
800
08
1000
10
1250
12
1350
13
1600
16
2000
20
2500
25
3200
32
4000
40
5000
50
Type of PE
Code
AL
G
Dimension of component
Two letters identifying the type of component.
Type
Code
Generic Code
Elbow
EL
Flange End
FE
Qwik Flange End
QF
Expension Joint
EJ
End Tap Box
ETB
Center Tap Box
CTB
Flat Tee
T
Unfused Reducer
R
Discrete Code
Edgewise Elbow
LE
Flatwise Elbow
LF
Edgewise Offset Elbow
OE
Flatwise Offset Elbow
OF
Double Left Elbow
DL
Double Right Elbow
DR
Flange End Edgewise Elbow
LEFE
Flange End Flatwise Elbow
LFFE
Flange End - Double left
FEDL
Flange End - Double right
FEDR
Straight Length - Feeder/Plug-in/Riser
ST
Phase Transition
PT
Degree of Pretection
Code
IP40
-IP54
M54
IP55***
M55
IP65***
M65
IP66***
M66
*** Available for feeder system only

K9CE20000

BC2GM

Catalogue numbers
Dimensions

One letter designating the application.

Catalogue Numbering System Generic v Discrete

Schneider Electric

37

Catalogue numbers and Straight lengths


dimensions
I-LINE II Copper Busway
Ordering

Complete the catalogue number by replacing by the rating and protection


degree.
Example:
Generic catalogue number of 1000A straight feeder, 3L+N+PE :
CFC2510GM54
Rating

Protection degree

Discrete catalogue number of a 10feet 1000A straight feeder, 3L+N+PE.


CFC2510G10STM54
Rating
** Protection degree
= the length of the straight feeder. If the number is larger than 10, the unit is inch. otherwise,
**
the unit is feet.

Straight feeder lengths


Type

Length

Cat. no.

Fixed

10 Feet

CFC23G10STM CFC25G10STM

CFC26GG10STM

Made to measure

16 inches ~
119 inches

CFC23G ** STM CFC25G ** STM

CFC26 ** GG ** STM

Catalogue numbers
Dimensions

3L + PE

3L + N + IGB

3L + N + ING

(1) See the Trunking cross-section table below.

Straight lengths with plug-in openings


Type

Length

N u m b e r o f Cta.no
opening
3L+PE

3L+N+IGB

3L+N+ING

Plug-in

4 feet

12

CPC23G4S2M

CPC25G4S2M

CPC26GG4S2M

6 feet

12

CPC23G6S2M

CPC25G6S2M

CPC26GG6S2M

22

CPC23G6S4M

CPC25G6S4M

CPC26GG6S4M

12

CPC23G10S2M

CPC25G10S2M

CPC26GG10S2M

22

CPC23G10S4M

CPC25G10S4M

CPC26GG10S4M

32

CPC23G10S6M

CPC25G10S6M

CPC26GG10S6M

4 feet

11

CRC23G4S1M

CRC25G4S1M

CRC26GG4S1M

6 feet

11

CRC23G6S1M

CRC25G6S1M

CRC26GG6S1M

21

CRC23G6S2M

CRC25G6S2M

CRC26GG6S2M

11

CRC23G10S1M

CRC25G10S1M

CRC26GG10S1M

21

CRC23G10S2M

CRC25G10S2M

CRC26GG10S2M

31

CRC23G10S3M

CRC25G10S3M

CRC26GG10S3M

10 feet

Riser

10 feet

Trunking cross-section
Rating (A)
Weight

3L + PE

(kg/m)

Type

800

1000

1250

1350

1600

2000

2500

3000

3200

4000

5000

6000

Feeder

14.8

18.0

20.5

25.0

27.2

31.4

43.3

57.6

63.5

70.3

87.9

108.9

Plug-in 17.3

21.1

23.7

28.1

30.4

34.5

46.5

60.7

65.2

76.1

91.1

111.2

17.8

21.7

24.9

31.0

33.9

40.9

58.1

71.0

76.9

87.6

108.0

134.8

Plug-in 20.3

24.8

28.0

34.1

37.1

44.0

61.2

74.1

80.1

93.9

111.2

137.9

20.4

24.3

27.9

34.9

38.2

45.9

65.3

79.0

85.8

98.1

119.8

150.4

Plug-in 22.9

27.4

31.0

38.0

41.4

49.0

68.4

82.1

89.0

104.4

123.0

153.5

3L + N + IGB

Feeder

3L + N + ING

Feeder

W(mm)

98

98

110

136

148

171

237

323

387

412

599

638

Figure

38

Schneider Electric

K9CE21020

Straight length components

Catalogue numbers and


dimensions
I-LINE II Copper Busway

Ordering

Complete the catalogue number by replacing by the rating and protection


degree.
Example:
Generic catalogue number of 1000A expansion joint, 3L+N+PE :
CFC2510GEJM54
Rating

Protection degree

Discrete catalogue number of a standard 1000A expansion joint,3L+N+PE:


CFC2510GEJM54
Rating

Protection degree

Expansion Joint
Type

Cat. no.
3L+PE

3L+N+IGB
CFC23GEJM CFC25GEJM

Fixed

3L+N+ING
CFC26GGEJM

Type Length Height Width (mm)


(mm)

800

508

343 343

1000 1250 1350 1600 2000 2500 3000 3200 4000 5000 6000
343

343

442

442

492

492

594

594

819 819

DD210807

Phase transition
Type Length
(mm)

DD210808

Fixed 966

A
B
C
N

Cat. no.
3L+PE
3L+N+IGB
3L+N+ING
CFC23G38PTM CFC25G38PTM CFC26GG38PTM

N
C
B
A

Unfused Reducer
Type

DD210811

Fixed

Length Cat. no.


(mm)
3L+PE
3L+N+IGB
CFC23GRM CFC25GRM
610

3L+N+ING
CFC26GGRM

Note: Replace R with below code. For example, CFC2520GR10M54.


Bolt side
Ampere
400 600 800 1000 1250 1350 1600
Rating
800
- R4 - R6 1000
- R4 - R6 - R8 1250
- R4 - R6 - R8 -R10 1350
- R6 - R8 -R10 -R12 1600
- R6 - R8 -R10 -R12 - R13 2000
- R8 -R10 -R12 - R13 - R16
2500
-R10 -R12 - R13 - R16
3000
-R10 -R12 - R13 - R16
3200
-R12 - R13 - R16
4000
- R13 - R16
5000
- R16
6000
Note: MCCB reducers are available. Contact us for details.

K9CE21020

Schneider Electric

2000

2500 3000 3200 4000

- R20
- R20
- R20
- R20
- R20
-

- R25
- R25
- R25
- R25
- R25

- R30
- R30
- R30
- R30

- R32
- R32

- R40

39

Catalogue numbers
Dimensions

(mm)

Fixed 1016

Catalogue numbers and


dimensions

Straight length components

I-LINE II Copper Busway

DD210813

End closure
Type

Rating
(A)

Dimension (mm)
A

Cat. no.

End closure

800
1000
1250
1350
1600
2000
2500
3000
3200
4000
5000
6000

110
110
123
148
161
184
250
336
399
425
612
650

ACF38EC
ACF38EC
ACF43EC
ACF53EC
ACF58EC
ACF67EC
ACF93EC
ACF13EC
ACF15EC
ACF17EC
ACF24EC
ACF25EC

Note: please add the suffix M for higher protection degree. For example, ACF38ECM54

Wall and floor flange (WF)


Rating
(A)

Catalogue numbers
Dimensions

800
1000
1250
1350
1600
2000
2500
3000
3200
4000
5000
6000

Rating
(A)
800
1000
1250
1350
1600
2000
2500
3000
3200
4000
5000
6000

Rating
(A)
800
1000
1250
1350
1600
2000
2500
3000
3200
4000
5000
6000

40

A(mm)
211
211
224
249
262
285
351
437
500
526
713
751

Straight Length
Y
W
152
203
152
203
152
203
178
203
203
203
229
203
279
203
381
203
432
203
457
203
660
203
686
203

Flanged End
Y
W
254
381
254
381
254
381
279
381
305
381
356
381
483
533
483
533
584
533
584
533
813
533
813
533

W(mm)
203
203
203
203
203
203
203
203
203
203
203
203

Flatwise Elbow Wall thickness (mm)


100
200
300
400
Y(mm)
229
279
330
381
229
279
330
381
254
305
356
407
305
356
406
457
305
356
406
457
356
406
457
508
432
483
533
584
559
610
660
711
660
711
762
813
686
737
787
838
940
991
1041
1092
1016
1067
1118
1168

Y(mm)
150
150
150
176
203
229
279
381
432
457
660
686

Edgewise Elbow Wall thickness (mm)


100
200
300
400
W(mm)
305
356
406
457
305
356
406
457
305
356
406
457
305
356
406
457
305
356
406
457
305
356
406
457
305
356
406
457
305
356
406
457
305
356
406
457
305
356
406
457
305
356
406
457
305
356
406
457

Schneider Electric

Cat. no
ACF38WF
ACF38WF
ACF43WF
ACF53WF
ACF58WF
ACF67WF
ACF93WF
ACF13WF
ACF15WF
ACF17WF
ACF24WF
ACF25WF

500

600

432
432
457
508
508
559
635
762
864
889
1143
1219

483
483
508
559
559
610
686
813
914
940
1194
1270

500

600

509
509
509
509
509
509
509
509
509
509
509
509

559
559
559
559
559
559
559
559
559
559
559
559

K9CE21020

Catalogue numbers and


dimensions

Elbows

I-LINE II Copper Busway


Ordering

Complete the catalogue number by replacing by the rating and protection


degree.
Example:
Generic catalogue number of 1000A flatwise elbow, 3L+N+PE
CFC2510GELM54
Rating

Protection degree

Discrete catalogue number of a 24 inch, 1000A flatwise elbow, 3L+N+PE:


CFC2510G24LFS13B11M54
Rating

S - the elbow side without joint pak


B - the elbow side with joint pak

Protection degree
- the length of the elbow side with joint pak
- the length of the elbow side without joint pak
- the total length of elbow

Type
Standard

Made to
measure
=+

Rating
(A)
800
1000
1250
1350
1600
2000
2500
3000
3200
4000
5000
6000

Cat. no
3L+PE
CFC2308GLFM11M
CFC2310GLFM11M
CFC2312GLFM11M
CFC2313GLFM12M
CFC2316GLFM12M
CFC2320GLFM12M
CFC2325GLFM14M
CFC2330GLFM15M
CFC2332GLFM16M
CFC2340GLFM17M
CFC2350GLFM21M
CFC2360GLFM21M

3L+N+IGB
CFC2508GLFM11M
CFC2510GLFM11M
CFC2512GLFM11M
CFC2513GLFM12M
CFC2516GLFM12M
CFC2520GLFM12M
CFC2525GLFM14M
CFC2530GLFM15M
CFC2532GLFM16M
CFC2540GLFM17M
CFC2550GLFM21M
CFC2560GLFM21M

All

CFC23 G LFS B M

CFC25 G LFS B M

Dimension
Type

Rating (A)

800
Standard (min)
1000
1250
1350
1600
2000
2500
3000
3200
4000
5000
6000
Made to measure All

Dimension (mm)
A
279
279
279
305
305
305
356
381
406
432
533
533
min ~ 1219

B
279
279
279
305
305
305
356
381
406
432
533
533
min ~ 1219

Flatwise elbows with made to measure angles


Type

Rating

Angle
(W)

Cat. no

3L+PE
3L+N+IGB
Made to
All
91 ~ 179 CFC23 G LFOAS B A M CFC25 G LFOAS B A M
measure
=+, A=A+angle
OA - special angle

K9CE22010

Schneider Electric

41

Catalogue numbers
Dimensions

Flatwise elbow

Catalogue numbers and


dimensions

Elbows

I-LINE II Copper Busway


Edgewise elbows
Type
Standard

Made to
measure

Rating
(A)
800
1000
1250
1350
1600
2000
2500
3000
3200
4000
5000
6000

Cat. no
3L+PE
CFC2308GLEM11M
CFC2310GLEM11M
CFC2312GLEM11M
CFC2313GLEM11M
CFC2316GLEM11M
CFC2320GLEM11M
CFC2325GLEM11M
CFC2330GLEM11M
CFC2332GLEM11M
CFC2340GLEM11M
CFC2350GLEM11M
CFC2360GLEM11M

3L+N+IGB
CFC2508GLEM11M
CFC2510GLEM11M
CFC2512GLEM11M
CFC2513GLEM11M
CFC2516GLEM11M
CFC2520GLEM11M
CFC2525GLEM11M
CFC2530GLEM11M
CFC2532GLEM11M
CFC2540GLEM11M
CFC2550GLEM11M
CFC2560GLEM11M

All

CFC23 G LES B M

CFC25 G LES B M

=+
Dimension
Type

Rating (A)

Catalogue numbers
Dimensions

Standard(min)
All
Made to measure All

Dimensions (mm)
A
279
min ~ 1219

B
279
min ~ 1219

Edgewise elbows with made to measure angles


Type

Rating Angle
(W)

Cat. no
3L+PE

3L+N+IGB

Made to All
91~179 CFC23 G LES B A M CFC25 G LES B A M
measure
=+, A=A+angle

Flatwise Tee
Rating Cat. no
(A)
3L+PE
CFC2308G33TS11B11S11M
Standard 800
1000
CFC2310G33TS11B11S11M
1250
CFC2312G33TS11B11S11M
1350
CFC2313G36TS12B12S12M
1600
CFC2316G36TS12B12S12M
2000
CFC2320G36TS12B12S12M
2500
CFC2325G42TS14B14S14M
3000
CFC2330G45TS15B15S15M
3200
CFC2332G48TS16B16S16M
4000
CFC2340G51TS17B17S17M
5000
CFC2350G63TS21B21S21M
6000
CFC2360G63TS21B21S21M

Type

Made to All
measure
=++

CFC23GTSBSM

3L+N+IGB
CFC2508G33TS11B11S11M
CFC2510G33TS11B11S11M
CFC2512G33TS11B11S11M
CFC2513G36TS12B12S12M
CFC2516G36TS12B12S12M
CFC2520G36TS12B12S12M
CFC2525G42TS14B14S14M
CFC2530G45TS15B15S15M
CFC2532G48TS16B16S16M
CFC2540G51TS17B17S17M
CFC2550G63TS21B21S21M
CFC2560G63TS21B21S21M
CFC25GTSBSM

Dimension
Type

Rating (A)

800
Standard (min)
1000
1250
1350
1600
2000
2500
3000
3200
4000
5000
6000
Made to measure All

42

Schneider Electric

Dimension (mm)
A
279
279
279
305
305
305
356
381
406
432
533
533
min ~ 1219

B
279
279
279
305
305
305
356
381
406
432
533
533
min ~ 1219

C
279
279
279
305
305
305
356
381
406
432
533
533
min ~ 1219

K9CE22010

Catalogue numbers and


dimensions

Double elbows

I-LINE II Copper Busway


Ordering

Complete the catalogue number by replacing by the rating and protection degree.
Example:
Generic catalogue number of 1000A double left elbow, 3L+N+PE:
CFC2510GELM54
Rating

Protection degree

Discrete catalogue number of a 29 inch, 1000A double left elbow, 3L+N+PE:


CFC2510G29DLB11C07S11M54
Rating

S - the elbow side without joint pak


B - the elbow side with joint pak
C or O - the straight feeder of the elbow

Protection degree

- the total length of elbow


- the length of the elbow side with joint pak
- the length of straight feeder
- the length of the elbow side without joint pak

Rating
(A)
Made to 800
measure 1000
1250
1350
1600
2000
2500
3000
3200
4000
5000
6000
Type

Cat. no
3L+PE
CFC2308GDLBCSM
CFC2310GDLBCSM
CFC2312GDLBCSM
CFC2313GDLBCSM
CFC2316GDLBCSM
CFC2320GDLBCSM
CFC2325GDLBCSM
CFC2330GDLBCSM
CFC2332GDLBCSM
CFC2340GDLBCSM
CFC2350GDLBCSM
CFC2360GDLBCSM

3L+N+IGB
CFC2508GDLBCSM
CFC2510GDLBCSM
CFC2512GDLBCSM
CFC2513GDLBCSM
CFC2516GDLBCSM
CFC2520GDLBCSM
CFC2525GDLBCSM
CFC2530GDLBCSM
CFC2532GDLBCSM
CFC2540GDLBCSM
CFC2550GDLBCSM
CFC2560GDLBCSM

=++
Dimension
Type

Rating (A)

800
Standard (min)
1000
1250
1350
1600
2000
2500
3000
3200
4000
5000
6000
Made to measure All

Dimension (mm)
A
279
279
279
305
305
305
356
381
406
432
533
533
min ~ 1219

B
279
279
279
279
279
279
279
279
279
279
279
279
min ~ 1219

C
178
178
178
203
203
203
279
279
330
330
457
457
min ~ 1016

Double right elbow


Rating
(A)
Made to 800
measure 1000
1250
1350
1600
2000
2500
3000
3200
4000
5000
6000
Type

Cat. no
3L+PE
CFC2308GDRBCSM
CFC2310GDRBCSM
CFC2312GDRBCSM
CFC2313GDRBCSM
CFC2316GDRBCSM
CFC2320GDRBCSM
CFC2325GDRBCSM
CFC2330GDRBCSM
CFC2332GDRBCSM
CFC2340GDRBCSM
CFC2350GDRBCSM
CFC2360GDRBCSM

3L+N+IGB
CFC2508GDRBCSM
CFC2510GDRBCSM
CFC2512GDRBCSM
CFC2513GDRBCSM
CFC2516GDRBCSM
CFC2520GDRBCSM
CFC2525GDRBCSM
CFC2530GDRBCSM
CFC2532GDRBCSM
CFC2540GDRBCSM
CFC2550GDRBCSM
CFC2560GDRBCSM

=++
Dimension
C

K9CE22020

Type

Rating (A)

800
Standard (min)
1000
1250
1350
1600
2000
2500
3000
3200
4000
5000
6000
Made to measure All
Schneider Electric

Dimension (mm)
A
279
279
279
305
305
305
356
381
406
432
533
533
min ~ 1219

B
279
279
279
279
279
279
279
279
279
279
279
279
min ~ 1219

C
178
178
178
203
203
203
279
279
330
330
457
457
min ~ 1016

43

Catalogue numbers
Dimensions

Double left elbow

Catalogue numbers and


dimensions

Offset elbows

I-LINE II Copper Busway


Flatwise offset elbow
Rating
(A)
Made to 800
measure 1000
1250
1350
1600
2000
2500
3000
3200
4000
5000
6000
Type

B
C

Cat. no
3L+PE
CFC2308GOFSOBM
CFC2310GOFSOBM
CFC2312GOFSOBM
CFC2313GOFSOBM
CFC2316GOFSOBM
CFC2320GOFSOBM
CFC2325GOFSOBM
CFC2330GOFSOBM
CFC2332GOFSOBM
CFC2340GOFSOBM
CFC2350GOFSOBM
CFC2360GOFSOBM

3L+N+IGB
CFC2508GOFSOBM
CFC2510GOFSOBM
CFC2512GOFSOBM
CFC2513GOFSOBM
CFC2516GOFSOBM
CFC2520GOFSOBM
CFC2525GOFSOBM
CFC2530GOFSOBM
CFC2532GOFSOBM
CFC2540GOFSOBM
CFC2550GOFSOBM
CFC2560GOFSOBM

=++
Dimension

Catalogue numbers
Dimensions

Type

Rating (A)

800
Standard (min)
1000
1250
1350
1600
2000
2500
3000
3200
4000
5000
6000
Made to measure All

Dimension (mm)
A
279
279
279
305
305
305
356
381
406
432
533
533
min ~ 1219

B
279
279
279
305
305
305
356
381
406
432
533
533
min ~ 1219

C
102
102
102
102
102
152
279
356
406
406
584
635
min ~ 1016

Edgewise offset elbow


Rating
(A)
Made to 800
measure 1000
1250
1350
1600
2000
2500
3000
3200
4000
5000
6000
Type

Cat. no
3L+PE
CFC2308GOESOBM
CFC2310GOESOBM
CFC2312GOESOBM
CFC2313GOESOBM
CFC2316GOESOBM
CFC2320GOESOBM
CFC2325GOESOBM
CFC2330GOESOBM
CFC2332GOESOBM
CFC2340GOESOBM
CFC2350GOESOBM
CFC2360GOESOBM

3L+N+IGB
CFC2508GOESOBM
CFC2510GOESOBM
CFC2512GOESOBM
CFC2513GOESOBM
CFC2516GOESOBM
CFC2520GOESOBM
CFC2525GOESOBM
CFC2530GOESOBM
CFC2532GOESOBM
CFC2540GOESOBM
CFC2550GOESOBM
CFC2560GOESOBM

=++
Dimension
Type
Standard (min)

Rating (A)

Dimension (mm)

All

A
279

B
279

C
152

min ~ 1219

min ~ 1219

min ~ 1016

Made to measure All

44

Schneider Electric

K9CE22020

Catalogue numbers and


dimensions

Elbow plus Flanged end

I-LINE II Copper Busway


Flatwise elbow flanged end
Cat. no
Rating
3L+PE
(A)
Made to 800
CFC2308GLFFE *F M
measure 1000
CFC2310GLFFE F M
Type

1250

CFC2312GLFFE *F M

1350

1600
2500
3000
4000
6000
=+
* = B or S.

CFC2320GLFFE *F M

CFC2520GLFFE *F M

CFC2516GLFFE *F M

CFC2325GLFFE *F M

CFC2525GLFFE *F M

CFC2332GLFFE *F M

CFC2532GLFFE *F M

CFC2350GLFFE *F M

CFC2550GLFFE *F M

CFC2340GLFFE *F M

5000

CFC2512GLFFE *F M

CFC2513GLFFE *F M

CFC2330GLFFE *F M

3200

CFC2508GLFFE *F M

CFC2510GLFFE *F M

CFC2313GLFFE *F M

CFC2316GLFFE *F M

2000

3L+N+IGB

CFC2360GLFFE *F M

CFC2530GLFFE *F M

CFC2540GLFFE *F M

CFC2560GLFFE *F M

B - elbow side with joint pak, S - elbow side without joint pak

Dimension
Rating (A)

800
Standard (min)
1000
1250
1350
1600
2000
2500
3000
3200
4000
5000
6000
Made to measure All

Dimension (mm)
A
204
204
204
204
229
229
254
305
330
356
457
457
min ~ 1219

B
279
279
279
305
305
305
356
381
406
432
533
533
min ~ 1219

Catalogue numbers
Dimensions

Type

Edgewise elbow flanged end


Rating Cat. no
(A)
3L+PE
Made to 800
CFC2308GLEFE *F M
measure 1000
CFC2310GLEFE F M
Type

1250
1350
1600
2000
2500
3000
3200
4000
5000
6000
=+

* = B or S.

*
CFC2312GLEFE *F M
CFC2313GLEFE *F M
CFC2316GLEFE *F M
CFC2320GLEFE *F M
CFC2325GLEFE *F M
CFC2330GLEFE *F M
CFC2332GLEFE *F M
CFC2340GLEFE *F M
CFC2350GLEFE *F M
CFC2360GLEFE *F M

3L+N+IGB
CFC2508GLEFE *F M
CFC2510GLEFE *F M
CFC2512GLEFE *F M
CFC2513GLEFE *F M
CFC2516GLEFE *F M
CFC2520GLEFE *F M
CFC2525GLEFE *F M
CFC2530GLEFE *F M
CFC2532GLEFE *F M
CFC2540GLEFE *F M
CFC2550GLEFE *F M
CFC2560GLEFE *F M

B - elbow side with joint pak, S - elbow side without joint pak

Dimension
Type

Rating (A)

800
Standard (min)
1000
1250
1350
1600
2000
2500
3000
3200
4000
5000
6000
Made to measure All

K9CE22020

Schneider Electric

Dimension (mm)
A
152
152
152
152
152
152
152
152
152
152
152
152
min ~ 1219

B
279
279
279
279
279
279
279
279
279
279
279
279
min ~ 1219

45

Catalogue numbers and


dimensions

Internal Grounding Elbows

I-LINE II Copper Busway


Flatwise Elbow
Rating Cat. no
(A)
1a
CFC2608GG22LFIS11B11M
Standard 800
1000
CFC2610GG22LFIS11B11M
1250
CFC2612GG22LFIS11B11M
1350
CFC2613GG24LFIS12B12M
1600
CFC2616GG24LFIS12B12M
2000
CFC2620GG24LFIS12B12M
2500
CFC2625GG28LFIS14B14M
3000
CFC2630GG30LFIS15B15M
3200
CFC2632GG32LFIS16B16M
4000
CFC2640GG34LFIS17B17M
5000
CFC2650GG42LFIS21B21M
6000
CFC2660GG42LFIS21B21M

Type

1a

B
L3
L1L2

L1 L2

Made to All
measure

L3 N

#&#'',&)3"

CFC26GGLFISBM

1b
CFC2508GG22LFOS11B11M
CFC2510GG22LFOS11B11M
CFC2512GG22LFOS11B11M
CFC2513GG24LFOS12B12M
CFC2516GG24LFOS12B12M
CFC2520GG24LFOS12B12M
CFC2525GG28LFOS14B14M
CFC2530GG30LFOS15B15M
CFC2532GG32LFOS16B16M
CFC2540GG34LFOS17B17M
CFC2550GG42LFOS21B21M
CFC2560GG42LFOS21B21M
CFC25GGLFOSBM

=+
Dimension

1b

Catalogue numbers
Dimensions

N L3

L2 L1

Type

B
S

L2 L1

#&#'',&/3"

Dimension (mm)
A
279
279
279
305
305
305
356
381
406
432
533
533
min ~ 1219

800
Standard (min)
1000
1250
1350
1600
2000
2500
3000
3200
4000
5000
6000
Made to measure All

N L3

Rating (A)

B
279
279
279
305
305
305
356
381
406
432
533
533
min ~ 1219

Flatwise elbows with made to measure angles


Type

Rating Angle
(A) (W)

3L+N+ING

Ground bar inside


Standard
All
91 ~ 179 CFC26GGLFIOASBAM
(min)
=+, A=A+angle

Ground bar outside


CFC26**GGLFOOASBAM

Edgewise Elbow
2a

B
N L3
L2

L1

L1
L2
L3
N

CFC2608GG22LEIS11B11

EL1

L2

2b
L3
N

Type

Rating
(A)
Standard 800
1000
1250
1350
1600
2000
2500
3000
3200
4000
5000
6000

Cat. no
2a
CFC2608GG22LEIS11B11M
CFC2610GG22LEIS11B11M
CFC2612GG22LEIS11B11M
CFC2613GG22LEIS11B11M
CFC2616GG22LEIS11B11M
CFC2620GG22LEIS11B11M
CFC2625GG22LEIS11B11M
CFC2630GG22LEIS11B11M
CFC2632GG22LEIS11B11M
CFC2640GG22LEIS11B11M
CFC2650GG22LEIS11B11M
CFC2660GG22LEIS11B11M

2b
CFC2508GG22LEOS11B11M
CFC2510GG22LEOS11B11M
CFC2512GG22LEOS11B11M
CFC2513GG22LEOS11B11M
CFC2516GG22LEOS11B11M
CFC2520GG22LEOS11B11M
CFC2525GG22LEOS11B11M
CFC2530GG22LEOS11B11M
CFC2532GG22LEOS11B11M
CFC2540GG22LEOS11B11M
CFC2550GG22LEOS11B11M
CFC2560GG22LEOS11B11M

Made to All
measure
=+

CFC26GGLEISBM

CFC25**GGLEOSBM

Dimension

Type

Rating (A)

Dimension (mm)

All

A
279

B
279

All

min ~ 1219

min ~ 1219

N
L3
L2
L1

Standard (min)
Made to measure

CFC2608GG22LEOS11B11

46

Schneider Electric

K9CE22020

Internal Grounding Elbows

Catalogue numbers and


dimensions
I-LINE II Copper Busway
Tee - Feeder

Type

Standard

Made to measure
=++

Rating

Cata. no

800
1000
1250
1350
1600
2000
2500
3000
3200
4000
5000
6000
All

3L+PE+ING
CFC2608GG33TS11B11S11M
CFC2610GG33TS11B11S11M
CFC2612GG33TS11B11S11M
CFC2613GG36TS12B12S12M
CFC2616GG36TS12B12S12M
CFC2620GG36TS12B12S12M
CFC2625GG42TS14B14S14M
CFC2630GG45TS15B15S15M
CFC2632GG48TS16B16S16M
CFC2640GG51TS17B17S17M
CFC2650GG63TS21B21S21M
CFC2660GG63TS21B21S21M
CFC26**GGTSBSM

Dimension
Rating (A)

800
Standard (min)
1000
1250
1350
1600
2000
2500
3000
3200
4000
5000
6000
Made to measure All

Dimension (mm)
A
279
279
279
305
305
305
356
381
406
432
533
533
min ~ 1219

B
279
279
279
305
305
305
356
381
406
432
533
533
min ~ 1219

C
279
279
279
305
305
305
356
381
406
432
533
533
min ~ 1219

Double left elbow


Rating
(A)
Made to 800
measure 1000
1250
1350
1600
2000
2500
3000
3200
4000
5000
6000
Type
S

L3

L2
L1

3a

L1
L2
L3
N

CFC2608GG29DLIS11C07B11

B
N L3
L2L1

3a

Cat. no
3a
CFC2608GGDLIBCSM
CFC2610GGDLIBCSM
CFC2612GGDLIBCSM
CFC2613GGDLIBCSM
CFC2616GGDLIBCSM
CFC2620GGDLIBCSM
CFC2625GGDLIBCSM
CFC2630GGDLIBCSM
CFC2632GGDLIBCSM
CFC2640GGDLIBCSM
CFC2650GGDLIBCSM
CFC2660GGDLIBCSM

3b
CFC2608GGDL0BCSM
CFC2610GGDL0BCSM
CFC2612GGDL0BCSM
CFC2613GGDL0BCSM
CFC2616GGDL0BCSM
CFC2620GGDL0BCSM
CFC2625GGDL0BCSM
CFC2630GGDL0BCSM
CFC2632GGDL0BCSM
CFC2640GGDL0BCSM
CFC2650GGDL0BCSM
CFC2660GGDL0BCSM

=++

Dimension
Type

Rating (A)

L1
L2
L3
N
S

EL1L2

CFC2608GG29DLIB11C07S11

3b

3b

EL1

L2

L3N

L3
N

800
Standard (min)
1000
1250
1350
1600
2000
2500
3000
3200
4000
5000
6000
Made to measure All

Dimension (mm)
A
279
279
279
305
305
305
356
381
406
432
533
533
min ~ 1219

B
279
279
279
279
279
279
279
279
279
279
279
279
min ~ 1219

C
178
178
178
203
203
203
279
279
330
330
457
457
min ~ 1016

C
A

N
L3
L2
L1

CFC2608GG29DLOB11C07S11

K9CE22020

N
L3
L2
L1

CFC2608GG29DLOS11C07B11

Schneider Electric

47

Catalogue numbers
Dimensions

Type

Internal Grounding Elbows

Catalogue numbers and


dimensions
I-LINE II Copper Busway
Double Right elbow
Type
B
N

L3

L2

L1

Rating
(A)
Made to 800
measure 1000
1250
1350
1600
2000
2500
3000
3200
4000
5000
6000

4a

L1
L2
L3
N
C

CFC2608GG29DRIB11C07S11

L3

L2
L1

4a

Cat. no
4a

4b

CFC2608GGDRIBCSM
CFC2610GGDRIBCSM
CFC2612GGDRIBCSM
CFC2613GGDRIBCSM
CFC2616GGDRIBCSM
CFC2620GGDRIBCSM
CFC2625GGDRIBCSM
CFC2630GGDRIBCSM
CFC2632GGDRIBCSM
CFC2640GGDRIBCSM
CFC2650GGDRIBCSM
CFC2660GGDRIBCSM

CFC2608GGDROBCSM
CFC2610GGDROBCSM
CFC2612GGDROBCSM
CFC2613GGDROBCSM
CFC2616GGDROBCSM
CFC2620GGDROBCSM
CFC2625GGDROBCSM
CFC2630GGDROBCSM
CFC2632GGDROBCSM
CFC2640GGDROBCSM
CFC2650GGDROBCSM
CFC2660GGDROBCSM

=++

L1
L2
L3
N

Dimension

CFC2608GG29DRIS11C07B11

Type

Catalogue numbers
Dimensions

EL1L2

L3N

4b

4b

EL1L2

L3N

N
L3
L2
L1

N
L3
L2
L1

CFC2608GG29DROS11C07B11

CFC2608GG29DROB11C07S11

Rating (A)

800
Standard (min)
1000
1250
1350
1600
2000
2500
3000
3200
4000
5000
6000
Made to measure All

Dimension (mm)
A
279
279
279
305
305
305
356
381
406
432
533
533
min ~ 1219

B
279
279
279
279
279
279
279
279
279
279
279
279
min ~ 1219

C
178
178
178
203
203
203
279
279
330
330
457
457
min ~ 1016

Flatwise offset elbow


Rating
(A)
Made to 800
measure 1000
1250
1350
1600
2000
2500
3000
3200
4000
5000
6000

Type

6a
A
N
L3
L2
L1

N
L3
L2
L1

CFC2608GG26OFIS11O04B11

Cat. no
6a
CFC2608GGOFISOBM
CFC2610GGOFISOBM
CFC2612GGOFISOBM
CFC2613GGOFISOBM
CFC2616GGOFISOBM
CFC2620GGOFISOBM
CFC2625GGOFISOBM
CFC2630GGOFISOBM
CFC2632GGOFISOBM
CFC2640GGOFISOBM
CFC2650GGOFISOBM
CFC2660GGOFISOBM

6b
CFC2608GGOFOSOBM
CFC2610GGOFOSOBM
CFC2612GGOFOSOBM
CFC2613GGOFOSOBM
CFC2616GGOFOSOBM
CFC2620GGOFOSOBM
CFC2625GGOFOSOBM
CFC2630GGOFOSOBM
CFC2632GGOFOSOBM
CFC2640GGOFOSOBM
CFC2650GGOFOSOBM
CFC2660GGOFOSOBM

=++
Dimension
Type

6b
A

L1
L2
L3
N
S
C

E
B

L1
L2
L3
N
B

CFC2608GG26OFOS11O04B11

48

Rating (A)

800
Standard (min)
1000
1250
1350
1600
2000
2500
3000
3200
4000
5000
6000
Made to measure All

Schneider Electric

Dimension (mm)
A
279
279
279
305
305
305
356
381
406
432
533
533
min ~ 1219

B
279
279
279
305
305
305
356
381
406
432
533
533
min ~ 1219

C
102
102
102
102
102
152
279
356
406
406
584
635
min ~ 1016

K9CE22020

Internal Grounding Elbows

Catalogue numbers and


dimensions
I-LINE II Copper Busway
Edgewise offset elbow
Type

5a
N
L3
L2
L1

E
S

N
L3
L2
L1

CFC2608GG28OEIS11O06B11

5a

5b

CFC2608GGOEISOBM
CFC2610GGOEISOBM
CFC2612GGOEISOBM
CFC2613GGOEISOBM
CFC2616GGOEISOBM
CFC2620GGOEISOBM
CFC2625GGOEISOBM
CFC2630GGOEISOBM
CFC2632GGOEISOBM
CFC2640GGOEISOBM
CFC2650GGOEISOBM
CFC2660GGOEISOBM

CFC2608GGOEOSOBM
CFC2610GGOEOSOBM
CFC2612GGOEOSOBM
CFC2613GGOEOSOBM
CFC2616GGOEOSOBM
CFC2620GGOEOSOBM
CFC2625GGOEOSOBM
CFC2630GGOEOSOBM
CFC2632GGOEOSOBM
CFC2640GGOEOSOBM
CFC2650GGOEOSOBM
CFC2660GGOEOSOBM

=++

5b
E

L1
L2
L3
N

Dimension
Type

Cat. no

Standard (min)

L1
L2
L3
N

Rating (A)

Dimension (mm)

All

A
279

B
279

C
152

min ~ 1219

min ~ 1219

min ~ 1016

Made to measure All

CFC2608GG28OEOS11O06B11

Flange end flatwise elbow


Rating
(A)
Made to 800
measure 1000
1250
1350
1600
2000
2500
3000
3200
4000
5000
6000

Type

N L3

L2 L1

7a

E
A

L2

L1

N L3

CFC2608GG19LFIFES11F08

N L3

L2 L1

7a

=+
* = B or S.

N L3

CFC2608GG19LFIFEB11F08

K9CE22020

7b
CFC2608GGLFOFE * FM
CFC2610GGLFOFE * FM
CFC2612GGLFOFE * FM
CFC2613GGLFOFE * FM
CFC2616GGLFOFE * FM
CFC2620GGLFOFE * FM
CFC2625GGLFOFE * FM
CFC2630GGLFOFE * FM
CFC2632GGLFOFE * FM
CFC2640GGLFOFE * FM
CFC2650GGLFOFE * FM
CFC2660GGLFOFE * FM

B - elbow side with joint pak, S - elbow side without joint pak

Dimension

Type

L2

Cat. no
7a
CFC2608GGLFIFE * FM
CFC2610GGLFIFE * FM
CFC2612GGLFIFE * FM
CFC2613GGLFIFE * FM
CFC2616GGLFIFE * FM
CFC2620GGLFIFE * FM
CFC2625GGLFIFE * FM
CFC2630GGLFIFE * FM
CFC2632GGLFIFE * FM
CFC2640GGLFIFE * FM
CFC2650GGLFIFE * FM
CFC2660GGLFIFE * FM

Rating (A)

L1

800
Standard (min)
1000
1250
1350
1600
2000
2500
3000
3200
4000
5000
6000
Made to measure All

Schneider Electric

Dimension (mm)
A
204
204
204
204
229
229
254
305
330
356
457
457
min ~ 1219

B
279
279
279
305
305
305
356
381
406
432
533
533
min ~ 1219

49

Catalogue numbers
Dimensions

Rating
(A)
Made to 800
measure 1000
1250
1350
1600
2000
2500
3000
3200
4000
5000
6000

Internal Grounding Elbows

Catalogue numbers and


dimensions
I-LINE II Copper Busway
Flange end edgewise elbow
Type
S

N L3
L2

L1

8a

L1

L2

L3
N

CFC2608GG17LEIFES11F06

EL1

L2

L3
N

8b

=+
* = B or S.

N
L3
L2
L1

Catalogue numbers
Dimensions

E
CFC2608GG17LEOFES11F06

Rating
(A)
Made to 800
measure 1000
1250
1350
1600
2000
2500
3000
3200
4000
5000
6000

Cat. no
8a

8b

CFC2608GGLEIFE * FM
CFC2610GGLEIFE * FM
CFC2612GGLEIFE * FM
CFC2613GGLEIFE * FM
CFC2616GGLEIFE * FM
CFC2620GGLEIFE * FM
CFC2625GGLEIFE * FM
CFC2630GGLEIFE * FM
CFC2632GGLEIFE * FM
CFC2604GGLEIFE * FM
CFC2650GGLEIFE * FM
CFC2660GGLEIFE * FM

CFC2608GGLEOFE * FM
CFC2610GGLEOFE * FM
CFC2612GGLEOFE * FM
CFC2613GGLEOFE * FM
CFC2616GGLEOFE * FM
CFC2620GGLEOFE * FM
CFC2625GGLEOFE * FM
CFC2630GGLEOFE * FM
CFC2632GGLEOFE * FM
CFC2640GGLEOFE * FM
CFC2650GGLEOFE * FM
CFC2660GGLEOFE * FM

B - elbow side with joint pak, S - elbow side without joint pak

Dimension
Type
Standard (min)

Rating (A)

Dimension (mm)

All

A
152

B
279

min ~ 1219

min ~ 1219

Made to measure All

50

Schneider Electric

K9CE22020

Flanged ends

Catalogue numbers and


dimensions
I-LINE II Copper Busway

Ordering

Complete the catalogue number by replacing by the rating and protection degree.
Example:
Generic catalogue number of 1000 A flanged end, 3L+N+PE
BFC2510GFEM54
Rating

Protection degree

Discrete catalogue number example of a 12 inch, 1000A flanged end, 3L+N+PE:


BFC2510G12FEBM54
Rating
* Protection degree
- the length of the straight feeder of flanged end
= B or S. B - with joint pak, S - without joint pak

*
Flanged end

Rating Cat. no
(A)
3L+PE

Satandard all
Made to
measure

3L+N+IGB

3L+N+ING

CFC23 G10FE * M CFC25G10FE * M CFC26GG10FE* M


CFC2308GFE * M CFC2508GFE * M CFC2608GFE * M

800
1000

CFC2310GFE * M CFC2510GFE * M CFC2610GFE * M

1250

CFC2312GFE * M CFC2512GFE * M CFC2612GFE * M

1350

CFC2313GFE * M CFC2513GFE * M CFC2613GFE * M

1600

CFC2316GFE * M CFC2516GFE * M CFC2616GFE * M


CFC2320GFE * M CFC2520GFE * M CFC2620GFE * M

2000
2500

CFC2325GFE * M CFC2525GFE * M CFC2625GFE * M

3000

CFC2330GFE * M CFC2530GFE * M CFC2630GFE * M


CFC2332GFE * M CFC2532GFE * M CFC2632GFE * M

3200
4000

CFC2340GFE * M CFC2540GFE * M CFC2640GFE * M

5000

CFC2350GFE * M CFC2550GFE * M CFC2650GFE * M

6000

CFC2360GFE * M CFC2560GFE * M CFC2660GFE * M

* =B with joint pak, S without joint pak


Dimension

Type
Standard
Made to measure
Rating (A)

Flanged Collar and Cutout and Drilling


Template 800A-6000A Feeder

Cutout

Flanged
Collar

8 Dia.
(Holes)

Flanged
Collar

K9CE24010

Rating (A)

Dimension (mm)

All

A
254

All

min ~ 1219

Dimension (mm)
A

800

162

81

1000

162

81

1250

162

81

1350

178

89

1600

203

102

2000

254

127

2500

378

127

3000

378

127

3200

480

121

119

4000

480

121

119

5000

705

117

118

118

6000

705

117

118

118

Rating
(A)

N Holes Dimension (mm)

800

10

98

130

187

254

296

335

1000

10

98

130

187

254

296

335

1250

10

98

130

187

254

296

335

1350

10

98

145

203

254

296

335

1600

10

98

171

229

254

296

335

2000

10

98

222

279

254

296

335

2500

16

88

87

346

403

406

451

487

3000

16

88

87

346

403

406

451

487

3200

18

88

87

448

505

406

451

487

4000

18

88

87

448

505

406

451

487

5000

22

88

87

673

730

406

451

487

6000

22

88

87

673

730

406

451

487

Schneider Electric

51

Catalogue numbers
Dimensions

Type

Catalogue numbers and


dimensions

Flanged ends

I-LINE II Copper Busway


Physical Data
Flanged Collar

Rating (A)

4-pole with Earth Bus


(Bottom View)

4-pole with Earth Bus

800
1000
1250
1350
1600
2000
2500
3000
3200
4000
5000
6000

3-pole with Earth Bus

Dimension (mm)
S
T
76
92
76
92
76
92
76
92
76
92
76
92
127
169
127
169
127
169
127
169
127
169
127
169

U
97
97
97
97
97
97
173
173
173
173
173
173

Flanged end termination details

Catalogue numbers
Dimensions

Figure 1

Figure 2

Figure 3

Figure 4

Rating (A)

Figure

Dimension (mm)
A
B
64
64
76
102
114
137
203
114
289
127
353
152
378
114
565
152
604

800
100
1250
1350
1600
2000
2500
3000
3200
4000
5000
6000

1
1
1
1
1
1
4
2
2
2
3
3

Rating (A)

Catalogue No.

800
1000
1250
1350
1600
2000
2500
3000
3200
4000
5000
6000

FLEX508
FLEX510
FLEX512
FLEX513
FLEX516
FLEX520
FLEX525
FLEX530
FLEX532
FLEX540
FLEX550
FLEX560

C
60
99
73
111
73

D
127
-

Flexible link

52

Schneider Electric

No. of Pieces required per phase&


neutral
2
3
3
4
4
5
7
8
8
10
13
15

K9CE24010

Catalogue numbers and


dimensions

Flanged ends

I-LINE II Copper Busway


Qwik Fange (Indoor Only)
Type

Rating Cat. no
(A)
3L+PE

800
Satandard 1000
1250

CFC2308GQF
CFC2310GQF

3L+N+IGB
CFC2508GQF
CFC2510GQF

CFC2312GQF

CFC2512GQF

1350
1600
2000
2500
3000
3200
4000
5000
6000

CFC2313GQF
CFC2316GQF
CFC2320GQF
CFC2325GQF
CFC2330GQF
CFC2332GQF
CFC2340GQF
CFC2350GQF
CFC2360GQF

CFC2513GQF
CFC2516GQF
CFC2520GQF
CFC2525GQF
CFC2530GQF
CFC2532GQF
CFC2540GQF
CFC2550GQF
CFC2560GQF

Note: please add the suffix M for higher protection degree. For example, CFC2508GQFM54

CL

71

32
A

Figure 1

Figure 2

800
1000
1250
1350
1600
2000
2500
3000
3200
4000
5000
6000

Dimension (mm)
A
B
650
432
650
432
650
432
650
432
650
432
650
432
650
445
650
533
650
584
650
610
650
813
650
838

Rating (A)

Figure

800
1000
1250
1350
1600
2000
2500
3000
3200
5000
6000

1
1
1
1
1
1
4
2
2
3
3

Dimension (mm)
A
B
64
64
76
102
114
137
165
114
289
127
353
114
565
152
604

X
267
267
267
267
267
267
279
364
428
453
641
679

Y
458
458
458
458
458
458
458
458
458
458
458
458

C
60
86
111
73

Z
190
190
190
190
190
190
190
190
190
190
190
190

Catalogue numbers
Dimensions

Rating (A)

D
127
-

Figure 3
CL

71

32

D
A

Figure 4

K9CE24010

Schneider Electric

53

Cable Tap Box

Catalogue numbers and


dimensions
I-LINE II Copper Busway

Ordering
DD202377

Complete the catalogue number by replacing by the rating and protection degree.
Example:
Generic catalogue number of 1000 A end cable tap box, 3L+N+PE:
CFC2510GETBM54
Rating

Protection degree

Discrete catalogue number example of a 10 inch, 1000A end cable tap box, 3L+N+PE:
CFC2510G10ETBBM54
Rating
* Protection degree
- the length of the straight feeder of end cable tap box
= B or S. B - with joint pak, S - without joint pak

*
Cable Tap Box - End

DD202381

Type

Rating
(A)

3L+N+IGB

3L+N+IGB

Standard

all

CFC23GETB * M

CFC25GETB* M

CFC26GGETB* M

Made to
measure

800

CFC2308GETB* M

CFC2508GETB* M

CFC2608GGETB* M

1000

CFC2310GETB* M

CFC2510GETB* M

CFC2610GGETB* M

1250

CFC2312GETB* M

CFC2512GETB* M

CFC2612GGETB* M

1350

CFC2313GETB* M

CFC2513GETB* M

CFC2613GGETB* M

1600

CFC2316GETB* M

CFC2516GETB* M

CFC2616GGETB* M

2000

CFC2320GETB* M

CFC2520GETB* M

CFC2620GGETB* M

2500

CFC2325GETB* M

CFC2525GETB* M

CFC2625GGETB* M

3000

CFC2330GETB* M

CFC2530GETB* M

CFC2630GGETB* M

3200

CFC2332GETB* M

CFC2532GETB* M

CFC2632GGETB* M

4000

CFC2340GETB* M

CFC2540GETB* M

CFC2640GGETB* M

5000

CFC2350GETB* M

CFC2550GETB* M

CFC2650GGETB* M

6000

CFC2360GETB* M

CFC2560GETB* M

CFC2660GGETB* M

Catalogue numbers
Dimensions

Cat. no.
3L+PE

Dimension
Type

DD202377

Standard
(Min)

Made to
measure

Rating
(A)

Lugs per Earth lugs


PH&N

800
1000
1250
1350
1600
2000
2500
3000
3200
4000
5000
6000

240 mm2
3
3
4
4
5
6
7
9
10
11
14
17

150 mm2
3
3
4
4
5
6
7
-

Dimension (mm)
240mm2
9
10
11
14
17

All

A
740
740
740
740
740
740
1000
1000
1000
1000
1000
1000

B
279
279
279
279
378
378
530
530
530
530
756
756

C
406
406
406
406
406
406
660
660
660
660
660
660

D
254
254
254
254
254
254
254
254
254
254
254
254

min

min

min

min ~ 1219

Cable Tap Box - Center


Type

Ampere
rating

Standard all

Cat. no.
3L+PE

3L+N+IGB

3L+N+ING

CFC23GETB*M

CFC25GETB*M

CFC26GGETB*M

Dimension
Type
Standard
(Min)

Rating (A) Lugs per PH&N Earth lugs


800
1000
1250
1350
1600
2000
2500

240 mm2
3
3
4
4
5
6
7

150 mm2
3
3
4
4
5
6
7

Dimension (mm)
A
889
889
889
889
889
889
1059

B
356
356
356
356
356
356
508

C
406
406
406
406
406
406
447

D
185
185
185
185
185
185
261

Note: please contact us for the ratings not shown above

54

Schneider Electric

K9CE26030

Catalogue numbers and


dimensions

Supports and fixings

I-LINE II Copper Busway


Flatwise horizontal hanger

Flatwise horizontal hanger

Rating
(A)

Dimension (mm)
A (mm)

B (mm)

Cat. no.

800

186

148

HF38F

1000
1250

186
199

148
161

HF38F
HF43F

1350

225

186

HF53F

1600

237

199

HF58F

2000

260

222

HF67F

2500

326

288

HF93F

3000

412

374

HF13F

3200

475

437

HF15F

4000

501

463

HF16F

5000

688

650

HF24F

6000

726

688

HF25F

Catalogue numbers
Dimensions

Type

Edgewise horizontal hanger


Type

Rating
(A)

Dimension (mm)

Cat. no.

A (mm)
212
212
212

HF43E
HF43E
HF43E

1350

250

HF58E

1600

250

HF58E

2000

276

HF67E

2500

339

HF93E

3000

438

HF13E

3200

501

HF15E

4000

527

HF16E

5000

714

HF24E

6000

752

HF26E

Edgewise horizontal hanger 800


1000
1250

K9CE26030

Schneider Electric

55

Catalogue numbers and


dimensions

Supports and fixings

I-LINE II Copper Busway


Vertical fixed hanger
Type

Rating(A)

Cat. no.

Vertical fixed hanger

all

HFV

Type
Vertical Spring hanger

Rating(A)
800
1000
1250
1350
1600
2000
2500
3000
3200
4000
5000
6000

Cat. no.
HFVS1
HFVS1
HFVS1
HFVS1
HFVS2
HFVS2
HFVS2
HFVS8
HFVS8
HFVS8
HFVS8
HFVS8

Catalogue numbers
Dimensions

Vertical spring hanger

56

Schneider Electric

K9CE26030

Catalogue numbers
Dimensions
K9CE26030

Schneider Electric

57

Straight lengths

Catalogue numbers and


dimensions
I-LINE II Copper Contact Busway

Ordering

Complete the catalogue number by replacing by the rating and protection


degree.
Example:
Generic catalogue number of 1000A straight feeder, 3L+N+PE :
BFC2510GM54
Rating

Protection degree

Discrete catalogue number of a 10feet 1000A straight feeder, 3L+N+PE.


BFC2510G10STM54
Rating
** Protection degree
= the length of the straight feeder. If the number is larger than 10, the unit is inch. otherwise,
**
the unit is feet.

Catalogue numbers
Dimensions

Straight feeder lengths


Type

Length L

Cat. no.

Fixed

10 Feet

3L + PE
3L + N + IGB
BFC23G10STM BFC25G10STM

3L + N + ING
BFC26G10STM

Made to measure

16 inches ~
119 inches

BFC23G ** STM BFC25G ** STM

BFC26G ** STM

Straight lengths with plug-in openings


Type

Length

Number of
opening

Cta.no
3L+PE

3L+N+IGB

3L+N+ING

Plug-in

4 feet

12

BPC23G4S2M

BPC25G4S2M

BPC26G4S2M

6 feet

12

BPC23G6S2M

BPC25G6S2M

BPC26G6S2M

22

BPC23G6S4M

BPC25G6S4M

BPC26G6S4M

12

BPC23G10S2M

BPC25G10S2M

BPC26G10S2M

22

BPC23G10S4M

BPC25G10S4M

BPC26G10S4M

32

BPC23G10S6M

BPC25G10S6M

BPC26G10S6M

11

BRC23G4S1M

BRC25G4S1M

BRC26G4S1M

6 feet

11

BRC23G6S1M

BRC25G6S1M

BRC26G6S1M

21

BRC23G6S2M

BRC25G6S2M

BRC26G6S2M

10 feet

11

BRC23G10S1M

BRC25G10S1M

BRC26G10S1M

21

BRC23G10S2M

BRC25G10S2M

BRC26G10S2M

31

BRC23G10S3M

BRC25G10S3M

BRC26G10S3M

10 feet

Riser

4 feet

Trunking cross-section
Type

800

1000

1250

1350

1600

2000

2500

3200

4000

5000

Feeder

13.0

14.2

15.9

16.5

18.0

20.5

28.4

33.2

44.8

50.4

Plug-in

15.8

17.3

18.8

19.6

21.2

23.6

31.5

36.3

47.0

53.6

Feeder

14.0

15.6

17.8

18.6

20.5

23.5

33.5

39.7

51.8

60.1

Plug-in

17.2

18.8

21.0

21.7

23.7

26.6

36.6

42.8

55.0

63.2

W(mm)

98

120

148

161

186

225

323

412

566

650

Figure

Rating (A)
Weight

3L + PE

(kg/m)
3L + N + IGB

58

Schneider Electric

K9CE21010

Catalogue numbers and


dimensions

Straight length components

I-LINE II Copper Contact Busway


Ordering

Complete the catalogue number by replacing by the rating and protection


degree.
Example:
Generic catalogue number of 1000A expansion joint, 3L+N+PE :
BFC2510GEJM54
Rating

Protection degree

Discrete catalogue number of a standard 1000A expansion joint,3L+N+PE:


BFC2510GEJM54
Rating

Protection degree

Expansion Joint
Cat. no.
3L+PE
Fixed

Type
Fixed

BFC23GEJM

3L+N+IGB
BFC25GEJM

Length
(mm)

Height
(mm)

800

1016

508

343 343

3L+N+ING
BFC26GEJM

Width (mm)
1000 1250 1350 1600 2000 2500 3200 4000 5000
343

343

442

442

492

594

819

819

Phase transition
Type Length
(mm)
Fixed 966

A
B
C
N

Cat. no.
3L+PE
3L+N+IGB
3L+N+ING
BFC23G38PTM BFC25G38PTM BFC26GG38PTM

N
C
B
A

Unfused Reducer
Type
Fixed

Length Cat. no.


(mm)
3L+PE
3L+N+IGB
BFC23GRM BFC25GRM
610

3L+N+ING
BFC26GRM

Note: Replace R with below code. For example, BFC2520GR10M54.


Bolt side
Ampere Rating 400
630
800
1000 1250 1350
800
R04 R06
1000
R04 R06 R08 1250
R04 R06 R08 R10 1350
R06 R08 R10 R12 1600
R06 R08 R10 R12 R13
2000
R08 R10 R12 R13
2500
R10 R12 R13
3200
R12 R13
4000
R13
5000
Note: MCCB reducers are available. Contact us for details.

K9CE21010

Schneider Electric

1600
R16
R16
R16
R16
R16

2000
R20
R20
R20
R20

2500
R25
R25
R25

3200
R32
R32

4000
R40

59

Catalogue numbers
Dimensions

Type

Catalogue numbers and


dimensions

Straight length components

I-LINE II Copper Contact Busway


End closure
Type

Rating
(A)

Dimension (mm)
A

Cat. no.

End closure

800
1000
1250
1350
1600
2000
2500
3200
4000
5000

110
132
161
174
199
237
336
425
578
663

ACF38EC
ACF47EC
ACF58EC
ACF63EC
ACF73EC
ACF88EC
ACF13EC
ACF17EC
ACF22EC
ACF26EC

Note: please add the suffix M for higher protection degree. For example, ACF38ECM54

Wall and floor flange (WF)


Rating
(A)

Catalogue numbers
Dimensions

800
1000
1250
1350
1600
2000
2500
3200
4000
5000

Rating
(A)
800
1000
1250
1350
1600
2000
2500
3200
4000
5000

Rating
(A)
800
1000
1250
1350
1600
2000
2500
3200
4000
5000

60

A(mm)
211
233
262
275
300
338
437
526
679
764

Straight Length
Y
W
152
229
174
229
203
229
203
229
229
229
279
229
381
229
457
229
620
229
711
229

Flanged End
Y
W
254
381
276
381
305
381
330
381
356
381
432
533
483
533
584
533
722
533
813
533

W(mm)
203
203
203
203
203
203
203
203
203
203

Flatwise Elbow Wall thickness (mm)


100
200
300
400
Y(mm)
229
279
330
381
305
356
406
457
305
356
406
457
330
381
432
483
356
406
457
508
432
483
533
584
559
610
660
711
686
737
787
838
1016
1067
1118
1168
1016
1067
1118
1168

Y(mm)
152
178
203
203
229
279
381
457
711
711

Edgewise Elbow Wall thickness (mm)


100
200
300
400
W(mm)
305
356
406
457
305
356
406
457
305
356
406
457
305
356
406
457
305
356
406
457
305
356
406
457
305
356
406
457
305
356
406
457
305
356
406
457
305
356
406
457

Schneider Electric

Cat. no
ACF38WF
ACF47WF
ACF58WF
ACF63WF
ACF73WF
ACF88WF
ACF13WF
ACF17WF
ACF22WF
ACF26WF

500

600

432
508
508
533
559
635
762
889
1219
1219

483
559
559
584
610
686
813
940
1270
1270

500

600

509
509
509
509
509
509
509
509
509
509

559
559
559
559
559
559
559
559
559
559

K9CE21010

Elbows

Catalogue numbers and


dimensions
I-LINE II Copper Contact Busway

Ordering

Complete the catalogue number by replacing by the rating and protection


degree.
Example:
Generic catalogue number of 1000A flatwise elbow, 3L+N+PE
BFC2510GELM54
Protection degree

Rating

Discrete catalogue number of a 24 inch, 1000A flatwise elbow, 3L+N+PE:


BFC2510G24LFS13B11M54
Rating

Protection degree

S - the elbow side without joint pak


B - the elbow side with joint pak

- the length of the elbow side with joint pak


- the length of the elbow side without joint pak
- the total length of elbow

Type

Rating
(A)

Standard 800
1000
1250
1350
1600
2000
2500
3200
4000
5000
Made to All
measure

Cat. no
3L+PE
BFC2308GLFM11M
BFC2310GLFM11M
BFC2312GLFM12M
BFC2313GLFM12M
BFC2316GLFM13M
BFC2320GLFM13M
BFC2325GLFM15M
BFC2332GLFM17M
BFC2340GLFM21M
BFC2350GLFM22M

3L+N+IGB
BFC2508GLFM11M
BFC2510GLFM11M
BFC2512GLFM12M
BFC2513GLFM12M
BFC2516GLFM13M
BFC2520GLFM13M
BFC2525GLFM15M
BFC2532GLFM17M
BFC2540GLFM21M
BFC2550GLFM22M

3L+N+ING
BFC2608GLFM11M
BFC2610GLFM11M
BFC2612GLFM12M
BFC2613GLFM12M
BFC2616GLFM13M
BFC2620GLFM13M
BFC2625GLFM15M
BFC2632GLFM17M
BFC2640GLFM21M
BFC2650GLFM22M

BFC23 G LFS B M BFC25 G LFS B M BFC26 G LFS B M

=+
Dimension
Type

Rating (A)

Dimension (mm)
A
279
279
305
305
330
330
381
432
533
559
min ~ 1219

800
Standard (min)
1000
1250
1350
1600
2000
2500
3200
4000
5000
Made to measure All

B
279
279
305
305
330
330
381
432
533
559
min ~ 1219

Flatwise elbows with made to measure angles


Type

Rating

Made to
All
measure

Angle
(W)

Cat. no
3L+PE

91 ~ 179 BFC23 G LFOAS B A M

3L+N+IGB

3L+N+ING

BFC25 G LFOAS B A M

BFC26 G LFOAS B A M

=+, A=A+angle
OA - special angle

K9CE21010

Schneider Electric

61

Catalogue numbers
Dimensions

Flatwise elbow

Elbows

Catalogue numbers and


dimensions
I-LINE II Copper Contact Busway
Edgewise elbows

Rating Cat. no
(A)
3L+PE
800
BFC2308GLEM11M
Standard
1000
BFC2310GLEM11M
1250
BFC2312GLEM11M
1350
BFC2313GLEM11M
1600
BFC2316GLEM11M
2000
BFC2320GLEM11M
2500
BFC2325GLEM11M
3200
BFC2332GLEM11M
4000
BFC2340GLEM11M
5000
BFC2350GLEM11M
Type

Made to All
measure

3L+N+IGB
BFC2508GLEM11M
BFC2510GLEM11M
BFC2512GLEM11M
BFC2513GLEM11M
BFC2516GLEM11M
BFC2520GLEM11M
BFC2525GLEM11M
BFC2532GLEM11M
BFC2540GLEM11M
BFC2550GLEM11M

3L+N+ING
BFC2608GLEM11M
BFC2610GLEM11M
BFC2612GLEM11M
BFC2613GLEM11M
BFC2616GLEM11M
BFC2620GLEM11M
BFC2625GLEM11M
BFC2632GLEM11M
BFC2640GLEM11M
BFC2650GLEM11M

BFC23GLESBM BFC25GLESBM BFC26GLESBM

=+
Dimension
Type
Standard(min)

Rating (A)

Dimensions (mm)

All

A
279

B
279

min ~ 1219

min ~ 1219

Catalogue numbers
Dimensions

Made to measure All

Edgewise elbows with made to measure angles


Type

Rating Angle
(W)

Made to All
measure

Cat. no
3L+PE

3L+N+ING

3L+N+IGB

91 ~ 179 BFC23GLESBAM BFC25GLESBAM BFC26GLESBAM

=+, A=A+angle

Flatwise Tee
Type

Rating Cat. no
(A)
3L+PE

3L+N+IGB

3L+N+ING

Standard 800
1000

BFC2308G33TS11B11S11M

BFC2508G33TS11B11S11M

BFC2608G33TS11B11S11M

BFC2310G33TS11B11S11M

BFC2510G33TS11B11S11M

BFC2610G33TS11B11S11M

1250

BFC2312G36TS12B12S12M

BFC2512G36TS12B12S12M

BFC2612G36TS12B12S12M

1350

BFC2313G36TS12B12S12M

BFC2513G36TS12B12S12M

BFC2613G36TS12B12S12M

1600

BFC2316G39TS13B13S13M

BFC2516G39TS13B13S13M

BFC2616G39TS13B13S13M

2000

BFC2320G39TS13B13S13M

BFC2520G39TS13B13S13M

BFC2620G39TS13B13S13M

2500

BFC2325G45TS15B15S15M

BFC2525G45TS15B15S15M

BFC2625G45TS15B15S15M

3200

BFC2332G51TS17B17S17M

BFC2532G51TS17B17S17M

BFC2632G51TS17B17S17M

4000

BFC2340G63TS21B21S21M

BFC2540G63TS21B21S21M

BFC2640G63TS21B21S21M

5000

BFC2350G66TS22B22S22M

BFC2550G66TS22B22S22M

BFC2650G66TS22B22S22M

BFC23GTSBSM

BFC25GTSBSM

BFC26GTSBSM

Made to All
measure
=++

Dimension
Type

Rating (A)

800
Standard (min)
1000
1250
1350
1600
2000
2500
3200
4000
5000
Made to measure All

62

Schneider Electric

Dimension (mm)
A

279
279
305
305
330
330
381
432
533
559
min ~ 1219

279
279
305
305
330
330
381
432
533
559
min ~ 1219

279
279
305
305
330
330
381
432
533
559
min ~ 1219

K9CE21010

Catalogue numbers and


dimensions

Double elbows

I-LINE II Copper Contact Busway


Ordering

Complete the catalogue number by replacing by the rating and protection degree.
Example:
Generic catalogue number of 1000A double left elbow, 3L+N+PE:
BFC2510GELM54
Rating

Protection degree

Discrete catalogue number of a 29 inch, 1000A double left elbow, 3L+N+PE:


BFC2510G29DLB11C07S11M54

Rating

S - the elbow side without joint pak


B - the elbow side with joint pak
C or O - the straight feeder of the elbow

Protection degree
- the total length of elbow
- the length of the elbow side with joint pak
- the length of straight feeder
- the length of the elbow side without joint pak

Rating Cat. no
(A)
3L+PE
800
BFC2308GDLBCSM
Standard
1000
BFC2310GDLBCSM
1250
BFC2312GDLBCSM
1350
BFC2313GDLBCSM
1600
BFC2316GDLBCSM
2000
BFC2320GDLBCSM
2500
BFC2325GDLBCSM
3200
BFC2332GDLBCSM
4000
BFC2340GDLBCSM
5000
BFC2350GDLBCSM
Type

3L+N+IGB
BFC2508GDLBCSM
BFC2510GDLBCSM
BFC2512GDLBCSM
BFC2513GDLBCSM
BFC2516GDLBCSM
BFC2520GDLBCSM
BFC2525GDLBCSM
BFC2532GDLBCSM
BFC2540GDLBCSM
BFC2550GDLBCSM

3L+N+ING
BFC2608GDLBCSM
BFC2610GDLBCSM
BFC2612GDLBCSM
BFC2613GDLBCSM
BFC2616GDLBCSM
BFC2620GDLBCSM
BFC2625GDLBCSM
BFC2632GDLBCSM
BFC2640GDLBCSM
BFC2650GDLBCSM

Dimension

Type

Rating (A)

800
Standard (min)
1000
1250
1350
1600
2000
2500
3200
4000
5000
Made to measure All

Dimension (mm)
A
279
279
305
305
330
330
381
432
533
559
min ~ 1219

B
279
279
279
279
279
279
279
279
279
279
min ~ 1219

C
178
178
203
203
229
229
305
356
406
635
min ~ 1016

Double right elbow


Rating Cat. no
(A)
3L+PE
800
BFC2308GDRBCSM
Standard
1000
BFC2310GDRBCSM
1250
BFC2312GDRBCSM
1350
BFC2313GDRBCSM
1600
BFC2316GDRBCSM
2000
BFC2320GDRBCSM
2500
BFC2325GDRBCSM
3200
BFC2332GDRBCSM
4000
BFC2340GDRBCSM
5000
BFC2350GDRBCSM
Type

=++
A

K9CE22020

3L+N+ING
BFC2608GDRBCSM
BFC2610GDRBCSM
BFC2612GDRBCSM
BFC2613GDRBCSM
BFC2616GDRBCSM
BFC2620GDRBCSM
BFC2625GDRBCSM
BFC2632GDRBCSM
BFC2640GDRBCSM
BFC2650GDRBCSM

Dimension
Type

3L+N+IGB
BFC2508GDRBCSM
BFC2510GDRBCSM
BFC2512GDRBCSM
BFC2513GDRBCSM
BFC2516GDRBCSM
BFC2520GDRBCSM
BFC2525GDRBCSM
BFC2532GDRBCSM
BFC2540GDRBCSM
BFC2550GDRBCSM

Rating (A)

800
Standard (min)
1000
1250
1350
1600
2000
2500
3200
4000
5000
Made to measure All
Schneider Electric

Dimension (mm)
A
279
279
305
305
330
330
381
432
533
559
min ~ 1219

B
279
279
279
279
279
279
279
279
279
279
min ~ 1219

C
178
178
203
203
229
229
305
356
406
635
min ~ 1016

63

Catalogue numbers
Dimensions

Double left elbow

Catalogue numbers and


dimensions

Offset elbows

I-LINE II Copper Contact Busway


Flatwise offset elbow
Rating Cat. no
(A)
3L+PE
BFC2308GOFSOBM
Standard 800
1000
BFC2310GOFSOBM
1250
BFC2312GOFSOBM
1350
BFC2313GOFSOBM
1600
BFC2316GOFSOBM
2000
BFC2320GOFSOBM
2500
BFC2325GOFSOBM
3200
BFC2332GOFSOBM
4000
BFC2340GOFSOBM
5000
BFC2350GOFSOBM

Type

3L+N+ING
BFC2608GOFSOBM
BFC2610GOFSOBM
BFC2612GOFSOBM
BFC2613GOFSOBM
BFC2616GOFSOBM
BFC2620GOFSOBM
BFC2625GOFSOBM
BFC2632GOFSOBM
BFC2640GOFSOBM
BFC2650GOFSOBM

Dimension

=++

Type

Catalogue numbers
Dimensions

3L+N+IGB
BFC2508GOFSOBM
BFC2510GOFSOBM
BFC2512GOFSOBM
BFC2513GOFSOBM
BFC2516GOFSOBM
BFC2520GOFSOBM
BFC2525GOFSOBM
BFC2532GOFSOBM
BFC2540GOFSOBM
BFC2550GOFSOBM

Rating (A)

800
Standard (min)
1000
1250
1350
1600
2000
2500
3200
4000
5000
Made to measure All

Dimension (mm)
A
279
279
305
305
330
330
381
432
533
559
min ~ 1219

B
279
279
305
305
330
330
381
432
533
559
min ~ 1219

C
102
102
102
152
229
254
356
406
533
635
min ~ 1016

Edgewise offset elbow


Rating Cat. no
(A)
3L+PE
BFC2308GOESOBM
Standard 800
1000
BFC2310GOESOBM
1250
BFC2312GOESOBM
1350
BFC2313GOESOBM
1600
BFC2316GOESOBM
2000
BFC2320GOESOBM
2500
BFC2325GOESOBM
3200
BFC2332GOESOBM
4000
BFC2340GOESOBM
5000
BFC2350GOESOBM

Type

=++

3L+N+ING
BFC2608GOESOBM
BFC2610GOESOBM
BFC2612GOESOBM
BFC2613GOESOBM
BFC2616GOESOBM
BFC2620GOESOBM
BFC2625GOESOBM
BFC2632GOESOBM
BFC2640GOESOBM
BFC2650GOESOBM

Dimension
Type
Standard (min)

3L+N+IGB
BFC2508GOESOBM
BFC2510GOESOBM
BFC2512GOESOBM
BFC2513GOESOBM
BFC2516GOESOBM
BFC2520GOESOBM
BFC2525GOESOBM
BFC2532GOESOBM
BFC2540GOESOBM
BFC2550GOESOBM

Rating (A)

Dimension (mm)

All

A
279

B
279

C
152

min ~ 1219

min ~ 1219

min ~ 1016

Made to measure All

64

Schneider Electric

K9CE22020

Catalogue numbers and


dimensions

Elbow plug flanged end

I-LINE II Copper Contact Busway


Flatwise elbow flanged end
Rating Cat. no
(A)
3L+PE

Type

Standard 800
1000
1250
1350
1600
2000
2500
3200
4000
5000
=+
* = B or S.

3L+N+IGB

3L+N+ING

BFC2308G LFFE *F M

BFC2508G LFFE *F M

BFC2312G LFFE *F M

BFC2512G LFFE *F M

BFC2316G LFFE *F M

BFC2516G LFFE *F M

BFC2310G LFFE *F M
BFC2313G LFFE *F M

BFC2320G LFFE *F M

BFC2325G LFFE *F M

BFC2610G LFFE *F M

BFC2513G LFFE *F M

BFC2613G LFFE *F M

BFC2520G LFFE *F M

BFC2620G LFFE *F M

BFC2612G LFFE *F M

BFC2616G LFFE *F M

BFC2525G LFFE *F M

BFC2625G LFFE *F M

BFC2540G LFFE *F M

BFC2640G LFFE *F M

BFC2332G LFFE *F M

BFC2532G LFFE *F M

BFC2350G LFFE *F M

BFC2550G LFFE *F M

BFC2340G LFFE *F M

BFC2608G LFFE *F M

BFC2510G LFFE *F M

BFC2632G LFFE *F M

BFC2650G LFFE *F M

B - elbow side with joint pak, S - elbow side without joint pak
Dimension
Rating (A)

Dimension (mm)
A
204
204
204
229
229
254
305
356
457
457
min ~ 1016

800
Standard (min)
1000
1250
1350
1600
2000
2500
3200
4000
5000
Made to measure All

B
279
279
305
305
330
330
381
432
533
559
min ~ 1219

Catalogue numbers
Dimensions

Type

Edgewise elbow flanged end


Rating Cat. no
(A)
3L+PE

Type

Standard 800
1000
1250
1350
1600
2000
2500
3200
4000
5000
=+

* = B or S.

BFC2308G LEFE *F M
BFC2310G LEFE *F M

3L+N+IGB

3L+N+ING

BFC2508G LEFE *F M

BFC2608G LEFE *F M

BFC2510G LEFE *F M

BFC2312G LEFE *F M

BFC2512G LEFE *F M

BFC2612G LEFE *F M

BFC2516G LEFE *F M

BFC2616G LEFE *F M

BFC2525G LEFE *F M

BFC2625G LEFE *F M

BFC2313G LEFE *F M

BFC2513G LEFE *F M

BFC2320G LEFE *F M

BFC2520G LEFE *F M

BFC2316G LEFE *F M

BFC2325G LEFE *F M

BFC2332G LEFE *F M
BFC2340G LEFE *F M

BFC2613G LEFE *F M

BFC2620G LEFE *F M

BFC2532G LEFE *F M

BFC2632G LEFE *F M

BFC2550G LEFE *F M

BFC2650G LEFE *F M

BFC2540G LEFE *F M

BFC2350G LEFE *F M

BFC2610G LEFE *F M

BFC2640G LEFE *F M

B - elbow side with joint pak, S - elbow side without joint pak
Dimension
Type
Standard (min)

Rating (A)

Dimension (mm)

All

A
152

B
279

min ~ 1016

min ~ 1219

Made to measure All

K9CE24010

Schneider Electric

65

Flanged ends

Catalogue numbers and


dimensions
I-LINE II Copper Contact Busway

Ordering

Complete the catalogue number by replacing by the rating and protection degree.
Example:
Generic catalogue number of 1000 A flanged end, 3L+N+PE
BFC2510GFEM54
Rating

Protection degree

Discrete catalogue number example of a 12 inch, 1000A flanged end, 3L+N+PE:


BFC2510G12FEBM54
Rating
* Protection degree
- the length of the straight feeder of flanged end
= B or S. B - with joint pak, S - without joint pak

*
Flanged end unit

Rating Cat. no
(A)
3L+PE

Type

Satandard all
800

Made to
measure

1000

3L+N+ING

BFC2310GFE * M BFC2510GFE * M

1250

BFC2312GFE * M BFC2512GFE * M

1350
1600
2000

Catalogue numbers
Dimensions

3L+N+IGB

BFC23G10FE * M BFC25G10FE * M
BFC2308GFE * M BFC2508GFE * M

3200
5000

BFC2612GFE* M
BFC2616GFE* M

BFC2325GFE * M BFC2525GFE * M

BFC2625GFE* M

BFC2332GFE * M BFC2532GFE * M
BFC2340GFE * M BFC2540GFE * M

4000

BFC2608GFE* M

BFC2610GFE* M

BFC2313GFE * M BFC2513GFE * M
BFC2316GFE * M BFC2516GFE * M
BFC2320GFE * M BFC2520GFE * M

2500

BFC26G10FE* M

BFC2350GFE * M BFC2550GFE * M
* =B with joint pak, S without joint pak

BFC2613GFE* M

BFC2620GFE* M

BFC2632GFE* M
BFC2640GFE* M

BFC2650GFE* M

Dimension
Type
Standard (min)

Rating (A)

Dimension (mm)

All

A
254

Made to measure All

Flanged Collar and Cutout and Drilling


Template

Cutout

Flanged
Collar

8 Dia.
(Holes)

Flanged
Collar

66

Rating (A)

min ~ 1219

Dimension (mm)
A

800

162

81

1000

203

102

1250

203

102

1350

229

114

1600

254

127

2000

327

108

2500

378

127

3200

480

121

119

4000

705

117

118

118

5000

705

117

118

118

Rating (A) N Holes

Dimension (mm)
E

800

10

98

130

187

254

296

335

1000

10

98

171

229

254

296

335

1250

10

98

171

229

254

296

335

1350

10

98

196

254

254

296

335

1600

10

98

222

279

254

296

335

2000

16

88

87

295

352

406

451

487

2500

16

88

87

346

403

406

451

487

3200

18

88

87

448

505

406

451

487

4000

22

88

87

673

730

406

451

487

5000

22

88

87

673

730

406

451

487

Schneider Electric

K9CE24010

Catalogue numbers and


dimensions

Flanged ends

I-LINE II Copper Contact Busway


Physical Data
Flanged Collar

Rating (A)

4-pole with Earth Bus


(Bottom View)

4-pole with Earth Bus

800
1000
1250
1350
1600
2000
2500
3200
4000
5000

3-pole with Earth Bus

Dimension (mm)
S
U
76
97
76
97
76
97
76
97
76
97
76
173
127
173
127
173
127
173
127
173

T
92
92
92
92
92
92
169
169
169
169

Flanged end termination details

Figure 2

Figure 3

Figure 4

Rating (A)

Figure

Dimension (mm)
A
64
86
114
127
152
191
114
152
137
165

800
1000
1250
1350
1600
2000
2500
3200
4000
5000

1
1
1
1
1
1
2
2
3
3

Rating (A)

Catalogue No.

800
1000
1250
1350
1600
2000
2500
3200
4000
5000

FLEX508
FLEX510
FLEX512
FLEX513
FLEX516
FLEX520
FLEX525
FLEX532
FLEX540
FLEX550

B
289
378
532
616

Catalogue numbers
Dimensions

Figure 1

C
60
73
60
60

Flexible link

K9CE24010

Schneider Electric

No. of Pieces required per phase&


neutral
2
3
3
4
4
5
7
8
10
13

67

Catalogue numbers and


dimensions

Flanged ends

I-LINE II Copper Contact Busway


Qwik Fange (Indoor Only)
Type

Rating Cat. no
(A)
3L+PE

800
Satandard 1000
1250

BFC2308GQF
BFC2310GQF

3L+N+IGB
BFC2508GQF
BFC2510GQF

BFC2312GQF

BFC2512GQF

1350
1600
2000
2500
3200
4000
5000

BFC2313GQF
BFC2316GQF
BFC2320GQF
BFC2325GQF
BFC2332GQF
BFC2340GQF
BFC2350GQF

BFC2513GQF
BFC2516GQF
BFC2520GQF
BFC2525GQF
BFC2532GQF
BFC2540GQF
BFC2550GQF

Note: please add the suffix M for higher protection degree. For example, BFC2508GQFM54

Catalogue numbers
Dimensions

Rating (A)

CL

71

800
1000
1250
1350
1600
2000
2500
3200
4000
5000

Dimension (mm)
A
B
584
432
584
432
584
432
584
432
584
432
584
432
584
533
584
610
584
864
584
864

Rating (A)

Figure

800
1000
1250
1350
1600
2000
2500
3200
4000
5000

1
1
1
1
1
1
2
2
3
3

X
267
267
267
267
267
267
365
454
692
692

Y
413
413
413
413
413
413
413
413
413
413

Z
190
190
190
190
190
190
190
190
190
190

32
A

Figure 1

Figure 2

Dimension (mm)
A
64
86
114
127
152
191
114
152
137
165

B
288
377
531
615

C
60
73
60
60

Figure 3

68

Schneider Electric

K9CE24010

Catalogue numbers and


dimensions

Cable Tap Box

I-LINE II Copper Contact Busway


Ordering

Complete the catalogue number by replacing by the rating and protection degree.
Example:
Generic catalogue number of 1000 A end cable tap box, 3L+N+PE:
BFC2510GETBM54
Rating

Protection degree

Discrete catalogue number example of a 10 inch, 1000A end cable tap box, 3L+N+PE:
BFC2510G10ETBBM54
Rating

Protection degree

- the length of the straight feeder of end cable tap box


= B or S. B -with joint pak, S - without joint pak

*
Cable Tap Box - End

Standard
Made to
measure

DD202381

Ampere
rating

Cat. no.
3L+PE

3L+N+IGB

3L+N+IGB

all

BFC23GETB*M

BFC25GETB*M

BFC26GETB*M

800

BFC2308GETB*M

BFC2508GETB*M

BFC2608GETB*M

1000

BFC2310GETB*M

BFC2510GETB*M

BFC2610GETB*M

1250

BFC2312GETB*M

BFC2512GETB*M

BFC2612GETB*M

1350

BFC2313GETB*M

BFC2513GETB*M

BFC2613GETB*M

1600

BFC2316GETB*M

BFC2516GETB*M

BFC2616GETB*M

2000

BFC2320GETB*M

BFC2520GETB*M

BFC2620GETB*M

2500

BFC2325GETB*M

BFC2525GETB*M

BFC2625GETB*M

3200

BFC2332GETB*M

BFC2532GETB*M

BFC2632GETB*M

4000

BFC2340GETB*M

BFC2540GETB*M

BFC2640GETB*M

5000

BFC2350GETB*M

BFC2550GETB*M

BFC2650GETB*M

Dimension
Type

Rating (A) Lugs per


PH&N
240 mm2
3
3
4
4
5
6
7
10
11
14

800
Made to measure 1000
1250
1350
1600
2000
2500
3200
4000
5000

Earth lugs
150 mm2
3
3
4
4
5
6
7
-

Dimension (mm)
240mm2
10
11
14

A
740
740
740
740
740
740
740
1000
1000
1000

B
279
279
378
279
378
378
429
530
756
756

C
406
406
406
406
406
406
406
660
660
660

D
254 ~ 1219
254 ~ 1219
254 ~ 1219
254 ~ 1219
254 ~ 1219
254 ~ 1219
254 ~ 1219
254 ~ 1219
254 ~ 1219
254 ~ 1219

Cable Tap Box - Center


DD202377

Type

Ampere
rating

Standard all

Cat. no.
3L+PE

3L+N+IGB

3L+N+ING

BFC23GETB*M BFC23GETB*M BFC26GETB*M

Dimension
Type

Standard

Rating (A)

800
1000
1250
1350
1600
2000
2500

Lugs per
PH&N

Earth lugs Dimension (mm)

240 mm2
3
3
4
4
5
6
7

150 mm2
3
3
4
4
5
6
7

A
889
889
889
889
889
889
1059

B
356
356
356
356
356
356
508

C
406
406
406
406
406
406
447

D
185
185
185
185
185
185
261

Note: please contact us for the ratings not shown above


K9CE25000

Schneider Electric

69

Catalogue numbers
Dimensions

Type

Catalogue numbers and


dimensions

Supports and fixings

I-LINE II Copper Contact Busway


Flatwise horizontal hanger
Type

Catalogue numbers
Dimensions

Flatwise horizontal hanger

Rating
(A)

Dimension (mm)
A (mm)

B (mm)

Cat. no.

800

186

148

HF38F

1000
1250

209
237

170
199

HF47F
HF58F

1350

250

212

HF63F

1600

274

236

HF73F

2000

312

274

HF88F

2500

412

374

HF13F

3200

501

463

HF16F

4000

654

616

HF22F

5000

739

701

HF26F

Rating(
A)

Dimension (mm)

Cat. no.

A (mm)
212
234
250

HF43E
HF43E
HF47E

1350

276

HF67E

1600

301

HF78E

2000

339

HF88E

2500

438

HF13E

3200

527

HF16E

4000

680

HF22E

5000

752

HF26E

Edgewise horizontal hanger


Type

Edgewise horizontal hanger 800


1000
1250

70

Schneider Electric

K9CE25000

Catalogue numbers and


dimensions

Supports and fixings

I-LINE II Copper Contact Busway

DD202374

Vertical fixed hanger


Type

Rating(A)

Cat. no.

Vertical fixed hanger

all

HFV

Type

Rating(A)

Cat. no.

Vertical Spring hanger 800

K9CE25000

Schneider Electric

Catalogue numbers
Dimensions

Vertical spring hanger


HFVS1

1000

HFVS1

1250

HFVS1

1350

HFVS1

1600

HFVS1

2000

HFVS2

2500

HFVS2

3200

HFVS2

4000

HFVS8

5000

HFVS8

71

Catalogue numbers and


dimensions

Catalogue-number coding

I-LINE Plug-in Unit


Catalogue-number composition (Plug - in unit)

Catalogue numbers
Dimensions

A.Plug - in unit with BS88 fusible switch


Amper Rating Reference No:

Code

30A - 200A

200A (vertical installation)

400A - 600A

BQ

800A - 1600A

TQ

Type of System:

Code

3L+PE

3L+N+PE

Voltage Level:

Code

690V

Maximum Ampere Rating (30A-1600A)

Code

200A

20

Standard

Code

Fusible switch with earth bus and complies


with UL standard

Fusible switch with earth bus and complies


with IEC standard

GE

P Q 4 6 20 GE

P K A 3 6 225 GN
B.Plug - in unit with Square D MCCB
Plug - in Types:

Code

Low current plug - in connection

High current plug - in connection

PB

High current bolt-on connection

PT

Amper Rating Reference No:

Code

Maximum 100A

Maximum 250A

Maximum 400A

Maximum 1000A

Maximum 1600A

Rated Breaking Capacity:

Code

Standard

High

Extra high (available for 400A or below)

Limited

No. of Poles (MCCB)

Code

3-Pole

Voltage Level

Code

380V-600V

Amper Rating (15A-1600A)

Code

225A

225

Earthing

Code

With earth bus and neutral

GN

72

Schneider Electric

K9CE25000

Catalogue numbers and


dimensions

Catalogue-number coding

I-LINE Plug-in Unit

Ampere Rating Reference

Code

15A -100 A

252A - 500A

PB

630A - 1000A

PT

Type of breaker

Code

NSD (15A - 100A)

NSN

NSEN (16A - 500A)

NSEN

NSES(16A - 500A)

NSES

NSEH(16A - 500A)

NSEH

NSL(16A - 500A)

NSL

NSN(16A - 1000A)

NSN

NSH(16A - 1000A)

NSH

Series

Code

34

34

Ampere Rating (16A-1000A)

Code

200A

200

Earthing

Code

with earth bar

Poles of breaker

Code

3 pole

4 pole

Handle operation

Code

Side handle

Rotate handle

with Vigi

K9CE25000

P NSN 34 200 G N S V

Catalogue numbers
Dimensions

C. Plug - in unit with Merlin Gerin MCCB

Schneider Electric

73

Catalogue numbers and


dimensions

I-LINE Plug-in Unit

I-LINE II
Plug-in Unit with Merlin-Gerin MCCB (500A and below)
NSEN breaker
Trip Rating

Interrupting Current

Number of

Catalogue Number
(3 poles)

Trip Rating

Interrupting Current Number of

kA (380/415V)

poles

Side handle, without Vigi

kA (380/415V)

poles

16
25
32
40
50
63
80

35
35
35
35
35
35
35

3, 4*
3, 4*
3, 4*
3, 4*
3, 4*
3, 4*
3, 4*

PNSEN34016GNS
PNSEN34025GNS
PNSEN34032GNS
PNSEN34040GNS
PNSEN34050GNS
PNSEN34063GNS
PNSEN34080GNS

100
125
160
200
250
400
500

35
35
35
35
35
35
35

3,
3,
3,
3,
3,
3,
3,

Trip Rating

Interrupting Current

Number of

Catalogue Number
(3 poles)

Trip Rating

Interrupting Current Number of

kA (380/415V)

poles

Side handle, without Vigi

kA (380/415V)

poles

16
25
32
40
50
63
80
NSEH breaker

50
50
50
50
50
50
50

3, 4*
3, 4*
3, 4*
3, 4*
3, 4*
3, 4*
3, 4*

PNSES34016GNS
PNSES34025GNS
PNSES34032GNS
PNSES34040GNS
PNSES34050GNS
PNSES34063GNS
PNSES34080GNS

100
125
160
200
250
400
500

50
50
50
50
50
50
50

3,
3,
3,
3,
3,
3,
3,

Trip Rating

Interrupting Current

Number of

Catalogue Number
(3 poles)

Trip Rating

Interrupting Current Number of

kA (380/415V)

poles

Side handle, without Vigi

kA (380/415V)

poles

16
25
32
40
50
63
80
NSN breaker

70
70
70
70
70
70
70

3, 4*
3, 4*
3, 4*
3, 4*
3, 4*
3, 4*
3, 4*

PNSEH34016GNS
PNSEH34025GNS
PNSEH34032GNS
PNSEH34040GNS
PNSEH34050GNS
PNSEH34063GNS
PNSEH34080GNS

100
125
160
200
250
400
500

70
70
70
70
70
70
70

3,
3,
3,
3,
3,
3,
3,

Trip Rating

Interrupting Current

Number of

Catalogue Number
(3 poles)

Trip Rating

Interrupting Current Number of

kA (380/415V)

poles

Side handle, without Vigi

kA (380/415V)

poles

16
25
32
40
50
63
80
NSD breaker

36
36
36
36
36
36
36

3, 4*
3, 4*
3, 4*
3, 4*
3, 4*
3, 4*
3, 4*

PNSN34016GNS
PNSN34025GNS
PNSN34032GNS
PNSN34040GNS
PNSN34050GNS
PNSN34063GNS
PNSN34080GNS

100
125
160
200
250
400
500

36
36
36
36
36
50
50

3, 4*
3, 4*
3, 4*
3, 4*
3, 4*
3, 4*
3, 4*

Trip Rating

Interrupting Current

Number of

Catalogue Number
(3 poles)

Trip Rating

Interrupting Current Number of

kA (380/415V)

poles

Side handle, without Vigi

kA (380/415V)

poles

15
20
25
30
40

25
25
25
25
25

3
3
3
3
3

PNSD34015GNS
PNSD34020GNS
PNSD34025GNS
PNSD34030GNS
PNSD34040GNS

50
60
75
80
100

25
25
25
25
25

3
3
3
3
3

4*
4*
4*
4*
4*
4*
4*

Catalogue Number
(3 poles)
Side handle, without
Vigi
PNSEN34100GNS
PNSEN34125GNS
PNSEN34160GNS
PNSEN34200GNS
PNSEN34250GNS
PBNSEN34400GNS
PBNSEN34500GNS

Catalogue numbers
Dimensions

NSES breaker

4*
4*
4*
4*
4*
4*
4*

4*
4*
4*
4*
4*
4*
4*

Catalogue Number
(3 poles)
Side handle, without
Vigi
PNSES34100GNS
PNSES34125GNS
PNSES34160GNS
PNSES34200GNS
PNSES34250GNS
PBNSES34400GNS
PBNSES34500GNS
Catalogue Number
(3 poles)
Side handle, without
Vigi
PNSEH34100GNS
PNSEH34125GNS
PNSEH34160GNS
PNSEH34200GNS
PNSEH34250GNS
PBNSEH34400GNS
PBNSEH34500GNS
Catalogue Number
(3 poles)
Side handle, without
Vigi
PNSN34100GNS
PNSN34125GNS
PNSN34160GNS
PNSN34200GNS
PNSN34250GNS
PBNSN34400GNS
PBNSN34500GNS
Catalogue Number
(3 poles)
Side handle, without
Vigi
PNSD34050GNS
PNSD34060GNS
PNSD34075GNS
PNSD34080GNS
PNSD34100GNS

* Note: For 4 poles plug-in unit, please replace the suffix GN with GT.

74

Schneider Electric

K9CE21010

Catalogue numbers and


dimensions

I-LINE Plug-in Unit

I-LINE II
Plug-in Unit with Merlin-Gerin MCCB (500A and below)
Trip Rating

Interrupting Current

Number of

Catalogue Number
(3 poles)

Trip Rating

Interrupting Current Number of

kA (380/415V)

poles

Side handle, without Vigi

kA (380/415V)

poles

16
25
32
40
50
63
80
NSL breaker

70
70
70
70
70
70
70

3, 4*
3, 4*
3, 4*
3, 4*
3, 4*
3, 4*
3, 4*

PNSH34016GNS
PNSH34025GNS
PNSH34032GNS
PNSH34040GNS
PNSH34050GNS
PNSH34063GNS
PNSH34080GNS

100
125
160
200
250
400
500

70
70
70
70
70
70
70

3, 4*
3, 4*
3, 4*
3, 4*
3, 4*
3, 4*
3, 4*

Trip Rating

Interrupting Current

Number of

Catalogue Number
(3 poles)

Trip Rating

Interrupting Current Number of

kA (380/415V)

poles

Side handle, without Vigi

kA (380/415V)

poles

16
25
32
40
50
63
80

150
150
150
150
150
150
150

3, 4*
3, 4*
3, 4*
3, 4*
3, 4*
3, 4*
3, 4*

PNSL34016GNS
PNSL34025GNS
PNSL34032GNS
PNSL34040GNS
PNSL34050GNS
PNSL34063GNS
PNSL34080GNS

100
125
160
200
250
400
500

150
150
150
150
150
150
150

3,
3,
3,
3,
3,
3,
3,

4*
4*
4*
4*
4*
4*
4*

Catalogue Number
(3 poles)
Side handle, without
Vigi
PNSH34100GNS
PNSH34125GNS
PNSH34160GNS
PNSH34200GNS
PNSH34250GNS
PBNSH34400GNS
PBNSH34500GNS
Catalogue Number
(3 poles)
Side handle, without
Vigi
PNSL34100GNS
PNSL34125GNS
PNSL34160GNS
PNSL34200GNS
PNSL34250GNS
PBNSL34400GNS
PBNSL34500GNS

* Note: For 4 poles plug-in unit, please replace the suffix GN with GT.

Plug-in Unit with Merlin-Gerin MCCB ( above 500A )


NSN breaker
Trip Rating
A
630
800
1000
NSH breaker
Trip Rating
A
630
800
1000

Interrupting Current
kA (380/415V)
50
50
50

Number of
poles
3, 4*
3, 4*
3, 4*

Catalogue Number (3 poles)


Without Vigi, Horizontal installation
PTNSN34630GNH
PTNSN34800GNH
PTNSN34100GNH

Without Vigi, Vertical installation


PTNSN34630GNV
PTNSN34800GNV
PTNSN34100GNV

Interrupting Current
kA (380/415V)
70
70
70

Number of
poles
3, 4*
3, 4*
3, 4*

Catalogue Number (3 poles)


Without Vigi, Horizontal installation
PTNSH34630GNH
PTNSH34800GNH
PTNSH34100GNH

Without Vigi, Vertical installation


PTNSH34630GNV
PTNSH34800GNV
PTNSH34100GNV

* Note: For 4 poles plug-in unit, please replace the suffix GN with GT.

K9CE21010

Schneider Electric

75

Catalogue numbers
Dimensions

NSH breaker

Catalogue numbers and


dimensions

I-LINE Plug-in Unit

I-LINE II

Catalogue numbers
Dimensions

Plug-in unit with Square D MCCB(15A-1600A)


PFA (Standard Interrupting Capacity)
Interrupting
Number of
Trip Rating
Current
poles
A
kA (380/415V)
3
15
18
3
20
18
3
30
18
3
40
18
3
50
18
3
60
18
3
70
18
3
90
18
3
100
18
3
125
25
3
150
25
3
175
25
3
200
25
3
225
25
PFH (High Interrupting Capacity)
Interrupting
Number of
Trip Rating
Current
poles
A
kA (380/415V)
3
15
25
3
20
25
3
30
25
3
40
25
3
50
25
3
60
25
3
70
25
3
90
25
3
100
25
3
125
30
3
150
30
3
175
30
PFC (Extra Interrupting Capacity)
Interrupting
Number of
Trip Rating
Current
poles
A
kA (380/415V)
3
15
65
3
20
65
3
30
65
3
40
65
3
50
65
3
60
65
3
70
65
3
90
65
3
100
65

Catalogue Number
(3 poles)
without Vigi
PFA34015GNS
PFA34020GNS
PFA34030GNS
PFA34040GNS
PFA34050GNS
PFA34060GNS
PFA34070GNS
PFA34090GNS
PFA34100GNS
PKA36125GNS
PKA36150GNS
PKA36175GNS
PKA36200GNS
PKA36225GNS
Catalogue Number
(3 poles)
without Vigi
PFH34015GNS
PFH34020GNS
PFH34030GNS
PFH34040GNS
PFH34050GNS
PFH34060GNS
PFH34070GNS
PFH34090GNS
PFH34100GNS
PKH36125GNS
PKH36150GNS
PKH36175GNS
Catalogue Number
(3 poles)
without Vigi
PFC34015GNS
PFC34020GNS
PFC34030GNS
PFC34040GNS
PFC34050GNS
PFC34060GNS
PFC34070GNS
PFC34090GNS
PFC34100GNS

Trip Rating
A
250
300
350
400
500
600
700
800
900
1000
1000
1200
1400
1600
Trip Rating
A
200
225
250
300
350
400
500
600
700
800
900
1000
Trip Rating
A
125
150
175
200
225
250
300
350
400

Interrupting
Current
kA (380/415V)
25
35
35
35
35
35
35
35
35
35
50
50
50
50

Number of

Interrupting
Current
kA (380/415V)
30
30
30
35
35
35
50
50
50
50
50
50

Number of

Interrupting
Current
kA (380/415V)
65
65
65
65
65
65
65
65
65

Number of

poles
3
3
3
3
3
3
3
3
3
3
3
3
3
3

poles
3
3
3
3
3
3
3
3
3
3
3
3

poles
3
3
3
3
3
3
3
3
3

Catalogue Number
(3 poles)
without Vigi
PKA36250GNS
PBLA36300GNS
PBLA36350GNS
PBLA36400GNS
PTMA36500GNSH/V
PTMA36600GNSH/V
PTMA36700GNSH/V
PTMA36800GNSH/V
PTMA36900GNSH/V
PTMA36100GNSH/V
PTPA36100GNSH/V
PTPA36120GNSH/V
PTPA36140GNSH/V
PTPA36160GNSH/V
Catalogue Number
(3 poles)
without Vigi
PKH36200GNS
PKH36225GNS
PKH36250GNS
PBLH36300GNS
PBLH36350GNS
PBLH36400GNS
PTMH36500GNSH/V
PTMH36600GNSH/V
PTMH36700GNSH/V
PTMH36800GNSH/V
PTMH36900GNSH/V
PTMH36100GNSH/V
Catalogue Number
(3 poles)
without Vigi
PKC36125GNS
PKC36150GNS
PKC36175GNS
PKC36200GNS
PKC36225GNS
PKC36250GNS
PBLC36300GNS
PBLC36350GNS
PBLC36400GNS

Plug-in with Fuse (30-1600A)


Fuse
Trip Rating
(A)

Number of poles

Catalogue Number (4Poles)


BS Standard Fuse

3, 4*
PQ4603GE
30
3, 4*
PQ4606GE
60
3, 4*
PQ4610GE
100
3, 4*
PQ4620GE
200
3, 4*
PQ4640GE
400
3, 4*
PQ4660GE
600
1.For rating above 600 A, please contact local sales office.
2.The fuse should be supplied by customer.

76

Schneider Electric

Catalogue Number (4
Poles)
FS Fuse
PQ4603G
PQ4606G
PQ4610G
PQ4620G
PQ4640G
PQ4660G

K9CE21010

Catalogue numbers

I-LINE Plug-in Unit

I-LINE II
Plug-in Unit with Merlin-Gerin MCCB
Type of Breaker

Trip Rating
16 - 100A
125 - 250A
375216179 375216179 516216200
451261179 592216200
516216200 516216200
592216200 592216200
516216200 516216200
592216200 592216200
11 - 12kg
15 - 16kg

NSD

without Vigi
without Vigi
NSEN / NSN
Plug-in Unit
with Vigi
Dimension
without
Vigi
(A*B*C)mm
NSES / NSEH / NSH
with Vigi
without Vigi
NSL
with Vigi
Weight of Plug-in Unit
P34G S V

Type of Trip
Breaker Rating

N: 3 pole
T: 4 pole

Type of Breaker

Trip Rating
252 - 500A
800372187
981327187
800372187
981327187
800372187
981327187
43 - 48kg

without Vigi
with Vigi
Plug-in Unit
without Vigi
NSES / NSEH / NSH
Dimension
with Vigi
(A*B*C)mm
without Vigi
NSL
with Vigi
Weight of Plug-in Unit
NSEN / NSN

Plug-in Unit Catalogue Number:

PB34G S V

Type of Trip
Breaker Rating

N: 3 pole
T: 4 pole

Type of Breaker
Plug-in Unit
Dimension
(A*B*C)mm

NSEN / NSN

Side
Vigi(optional)
handle
(optional)
Trip Rating
630 - 1000A

without Vigi

803359352

NSES / NSEH / NSH without Vigi

803359352

Weight of Plug-in Unit


Plug-in Unit Catalogue Number:

78 - 80kg
PT34G

Type of Trip
Breaker Rating

K9CE21010

Side
Vigi(optional)
handle
(optional)

Schneider Electric

Catalogue numbers
Dimensions

Plug-in Unit Catalogue Number:

N: 3 pole
T: 4 pole

H: horizontal installation
V: vertical installation

77

Catalogue numbers

I-LINE Plug-in Unit

I-LINE II
Plug-in unit with Square D MCCB

MCCB Type
F
K
L

Plug-in Unit Dimension (A*B*C)mm


A(standard Interrupting)
B(High Interrupting)
330210168
330210168
416216203
416216203
694387181
694387181
803359318
803359318
1441656406
1441656406

Figure
C(Extra High Interrupting)
330210168
416216203
962462257
-

1
1
2
3
4
4

Catalogue numbers
Dimensions

M
P

Trip rating(A)
15 - 100
125 - 250
300 - 400
300 - 600
500 - 1000
1000 - 1600

78

Schneider Electric

K9CE21010

Catalogue numbers

I-LINE Plug-in Unit

I-LINE II
Plug - in Unit with Fuse
Plug-in Unit Dimension(ABC) mm
379225168
379225168
480225168
571411291
1067532349
1067532349
1264473315
1264473315
1429616406
1429616406

Figure
1
1
1
2
3
3
4
4
4
4

Catalogue numbers
Dimensions

Trip Rating (A)


30
60
100
200
400
600
800
1000
1200
1600

K9CE21010

Schneider Electric

79

I-LINE Plug-in Unit

Catalogue numbers

I-LINE II

Catalogue numbers
Dimensions

Required Clearances for Plug-in Mounting (Check these dimensions carefully before installing busway lengths)

Vertical mounting - Fusible Units


Fusible switch plug-in units (30-100A) mounts on either
side of the vertical busbar trunking. The operating
handle is on the top, and when mounted on the opposite
side, the handle is on the bottom.
The 400A-1600A fusible units mount only on the front of
the busbar trunking. The handle is on the cover.

Plug-in Unit with Merlin-Gerin MCCB


MCCB type
NSN,NSD,NSEN,NSES
NSH,NSEH
NSL,NSN,NSD,NSEN,NSES,NSEH
NSL,NSH,NSN,NSD,NSEN,NSES,NSEH
NSL,NSH,NSN,NSEN,NSES,NSEH

IMPORTANT: orientation of the busbar trunking is essential for


proper mounting of plug-in units. The busbar trunking must be
positioned as shown above so that the top marking is to the
right and the neutral position to the left.

Circuit Breaker Units:

Circuit breaker plug-in units may be installed on both sides of a


riser.

Trip Rating
(A)
16 - 100
16 - 250
125 - 250
252 - 500
630 - 1000

A
(mm)
651
651
651
910
932

F
(mm)
60
60
60
145
160

H
(mm)
260
280
280
380
406

Trip Rating
(A)
30 - 60
100
200
400
600

A
(mm)
387
387
699
1524
1524

F
(mm)
203
304
381
184
184

H
(mm)
203
203
381
457
457

Trip Rating
(A)
15 - 100
15 - 100
125 - 250
250 - 400
250 - 400
500 - 1000
1000 - 1600

A
(mm)
530
651
651
906
889
894
1448

F
(mm)
54
73
60
142
203
159
260

H
(mm)
254
279
279
381
508
406
610

Plug-in Unit with Fuse

Q
Q(S)
BQ

Plug-in unit with Square D MCCB


MCCB Type
FA,FH
FC
FA,FH,FC
LA,LH
LX,LC
MA,MH,MX,ME
PA.PH,PX,PE

80

Schneider Electric

K9CE21010

Characteristics

82

Designing with I-LINE II busbar trunking system

84

Harmonic currents

88

Fire resistance

90

Measurements and metering

92

Direct current

94

Design guide

DD202437

Design guide

K9CE32000

Schneider Electric

81

Characteristics

Design guide

I-LINE II Copper Busway


Characteristics of straight lengths
Symbol

Unit

General characteristics

Busbar trunking rating (A)


800

Compliance with standards

1000 1250 1350 1600 2000 2500 3000 3200 4000 5000 6000

IEC/EN 60439-2

Protection degree

IP

40~66

Rated insulation voltage

Ui

1000

Rated operating voltage

Ue

1000

Operating frequency

Hz

50/60

Allowable rated short-time withstand current (t = 1 s)

Icw

kA

40

50

50

50

60

60

75

80

90

100

120

120

Allowable rated peak current

Ipk

kA

84

105

105

105

132

132

165

176

198

220

264

264

0.050 0.045 0.037 0.028 0.024 0.020 0.014 0.012 0.011 0.009 0.008 0.006

Short-circuit current withstand

Conductor characteristics
Phase conductors
Average resistance at an ambient temperature of 20C R20

m/m

Average resistance at Inc

R1

m/m 0.068 0.056 0.049 0.037 0.034 0.026 0.018 0.016 0.014 0.012 0.011 0.008

Average reactance at Inc and at 50 Hz

X1

m/m 0.029 0.027 0.026 0.018 0.016 0.015 0.012 0.010 0.009 0.007 0.006 0.005

Average impedance at Inc and at 50 Hz

Z1

m/m 0.074 0.062 0.055 0.041 0.037 0.030 0.021 0.019 0.017 0.014 0.012 0.009

Protective conductor (PE)


Average resistance at an ambient temperature of 20C

m/m 0.155 0.166 0.146 0.122 0.110 0.095 0.075 0.071 0.047 0.046 0.041 0.035

Voltage drop
Line-to-line voltage drop, in volts (V) per 100 metres and per amp (A) at 50 Hz with concentrated load. For
the case of loads distributed over the run, the voltage drops need times the load distribution factor (see
more details in page 86).

Design guide

For a cosine of

V/100 m/A

0.094 0.097 0.105 0.086 0.094 0.091 0.078 0.085 0.076 0.082 0.094 0.083

0.95

0.102 0.107 0.118 0.095 0.103 0.102 0.090 0.097 0.088 0.094 0.106 0.094

0.9

0.102 0.108 0.120 0.096 0.103 0.104 0.093 0.100 0.091 0.096 0.108 0.096

0.85

0.101 0.107 0.120 0.095 0.102 0.104 0.094 0.100 0.091 0.096 0.108 0.096

0.8

0.099 0.106 0.118 0.094 0.101 0.103 0.094 0.100 0.091 0.096 0.108 0.095

Choice of products when harmonics are present (see harmonic currents for more details).
Rated current according to THD3 (3 rd order THD < 15%
800
distortion)
15% < THD < 33%
THD > 33%

1000

1250

1350

1600

2000

2500

3000

3200

4000

5000

6000

800

1000

1000

1350

1600

2000

2500

2500

3000

4000

5000

800

800

1000

1350

1600

2000

2000

2500

3000

4000

Allowable current as a function of ambient temperature


I-LINE II busbar trunking is sized to operate at an ambient air does not exceed +40 C and its average over a period of 24 h does not exceed
+40 C, above this value, the busbar trunking must be derated.
Where k1 = ambient temperature derating coefficient.
Ambient temperature 24 hours average
Busbar trunking

82

k1

40

45

50

55

60

65

70

k1=1

k1=0.95

k1=0.90

k1=0.85

k1=0.8

k1=0.74

k1=0.67

Schneider Eletric

K9CE31000

Characteristics

Design guide

I-LINE II Copper Contact Busway


Characteristics of straight lengths
Symbol

Unit

General characteristics

Busbar trunking rating (A)


800

Compliance with standards

1000

1250

1350

1600

2000

2500

3200

4000

5000

IEC/EN 60439-2

Protection degree

IP

40~66

Rated insulation voltage

Ui

1000

Rated operating voltage

Ue

1000

Operating frequency

Hz

50/60

Allowable rated short-time withstand current (t = 1 s)

Icw

kA

40

50

50

50

65

65

90

100

120

150

Allowable rated peak current

Ipk

kA

84

105

105

105

143

143

198

220

264

330

Short-circuit current withstand

Conductor characteristics
Phase conductors
Average resistance at an ambient temperature of 20C R20

m/m 0.071

0.057

0.043

0.038

0.032

0.025

0.021

0.016

0.012

0.010

Average resistance at Inc

R1

m/m 0.073

0.064

0.055

0.049

0.035

0. 033

0.029

0.020

0.017

0.014

Average reactance at Inc and at 50 Hz

X1

m/m 0.043

0.042

0.013

0.013

0.025

0.012

0.010

0.008

0.008

0.005

Average impedance at Inc and at 50 Hz

Z1

m/m 0.085

0.076

0.056

0.051

0.043

0.035

0.031

0.021

0.018

0.015

m/m 0.186

0.168

0.120

0.118

0.107

0.117

0.065

0.047

0.039

0.036

Protective conductor (PE)


Average resistance at an ambient temperature of 20C

Voltage drop

For a cosine of

0.102

0.111

0.118

0.115

0.096

0.113

0.127

0.109

0.114

0.118

0.95

0.115

0.128

0.121

0.119

0.113

0.121

0.133

0.117

0.126

0.126

0.9

0.118

0.131

0.119

0.117

0.116

0.120

0.132

0.117

0.127

0.125

V/100 m/A

0.85

0.118

0.132

0.115

0.114

0.118

0.118

0.129

0.115

0.127

0.123

0.8

0.117

0.132

0.111

0.111

0.118

0.116

0.126

0.113

0.125

0.121

Choice of products when harmonics are present (see harmonic currents for more details).
Rated current according to THD3 (3 rd order THD < 15%
800
distortion)
15% < THD < 33%
THD > 33%

1000

1250

1350

1600

2000

2500

3200

4000

5000

800

1000

1000

1350

1600

2000

2500

3000

4000

800

800

1000

1350

1600

2000

2500

3000

Allowable current as a function of ambient temperature


I-LINE II busbar trunking is sized to operate at an ambient air does not exceed +40 C and its average over a period of 24 h does not exceed
+40 C, above t is value, the busbar trunking must be derated.
Where k1 = ambient temperature derating coefficient.
Ambient temperature 24 hours average
Busbar trunking

K9CE31000

k1

40

45

50

55

60

65

70

k1=1

k1=0.95

k1=0.90

k1=0.85

k1=0.8

k1=0.74

k1=0.67

Schneider Eletric

83

Design guide

Line-to-line voltage drop, in volts (V) per 100 metres and per amp (A) at 50 Hz with concentrated load. For
the case of loads distributed over the run, the voltage drops need times the load distribution factor (see
more details in page 86).

Design guide

Designing with I-LINE II busbar


trunking system

I-LINE II
Apart from extreme atmospheres, I-LINE II can be installed anywhere!
The order described below is only aimed at presenting the different stages for a
simple installation.
For a detailed design, it is necessary to use appropriate tools, approved by control
bodies, in compliance with local installation standards.

Design order:

1 Determining the current rating (Ib).


2 Calculating the nominal current (In) taking into account derating coefficients.
3 Choosing the busbar trunking rating.
4 Identifing the IPxx protection.
5 Checking the rating with respect to allowable voltage drop.
6 Checking the rating with respect to short-circuit withstand current.
7 Protecting against busbar trunking overloads

1 - Determining the current rating (Ib)


Determining by the transformer capacity:
Usc: 400/230V

Usc: 690/400V

P(KVA)

In(A)

Usc(%) Isc(KA)

Ib(A)

50

72

P(KVA)

In(A)

Usc(%)

Isc(KA)

Ib(A)

100

50

42

100

144

100

160

100

84

160

160

231

250

160

134

250

250

361

400

250

209

400

400

577

14

630

400

335

630

630

909

23

1000

630

527

13

1000

800

1154

19

1250

800

669

11

1250

1000

1443

24

1600

1000

837

14

1600

1250

1804

30

2000

1250

1046

17

2000

1600

2309

38

2500

1600

1338

22

2500

2000

2886

48

3000

2000

1673

28

3000

2500

3608

60

4000

2500

2091

35

4000

3150

4545

76

5000

3150

2635

44

5000

Determining by the equipment loads:


Design guide

Calculation of the total current (Ib) absorbed by a run is equal to the sum of the
currents absorbed by all of the loads.
The loads do not all operate at the same time and, as they are not continuously at
full load, a stacking or simultaneity factor Ks has to be taken into account:
Ib = Ib load x Ks
Application

Number of loads

Ks coefficient

Lighting, heating

Distribution of main circuits

2...3

0.9

4...5

0.8

6...9

0.7

10...40

0.6

40 and over

0.5

Caution: for industrial installations, remember to take into account future increases in the
number of machines. A 20 % reserve is recommended.

Determining by the floor loads:

Calculation of the total current (Ib) absorbed of one building is equal to the sum of
the currents absorbed by all of the load of all floors.
The floors do not all operate at the same time and, as they are not continuously at
full loads, a stacking or simultaneity factor Ks and Kf has to be taken into account:
Ib floor= Ib load x Ks (as above)
Ib = Ib floor x Kf

84

Application

Kf coefficient

Apartments

Lighting for commerical using

0.9

Elevators and general service

0.7

conference rooms

0.6

Small office

0.5

Large office

0.4

Schneider Eletric

K9CE31000

Designing with I-LINE II busbar


trunking system

Design guide

I-LINE II
2- Calculating nominal current (ln) by applying a derating coefficient
Ambient temperature
I-LINE II busbar trunking is sized to operate at an ambient air does not exceed
+40 C and its average over a period of 24 h does not exceed +40 C, above this
value, the busbar trunking must be derated.
Example: I-LINE II 1250 A installed inside with an ambient temperature of 50 C:
In = 1250 x 0.90 = 1215 A.
In Ib x k1 = Iz
Where k1 = ambient temperature derating coefficient.
Ambiant temperature 24 hours average
k1

40

45

k1=1

k1=0.95 k1=0.90

50

55

60

65

k1=0.85 k1=0.8

70

k1=0.74 k1=0.67

3 - Choosing the busbar trunking rating according to the nominal current ln


Nominal current In (A)

Busbar trunking rating

0 to 800

800

801 to 1000

1000

1001 to 1250

1250

1251 to 1350

1350

1351 to 1600

1600

1601 to 2000

2000

2001 to 2500

2500

2501 to 3000

3000

3001 to 3200

3200

3201 to 4000

4000

4001 to 5000

5000

5001 to 6000

6000

4 - Identifing the IPxx protection


1st characteristic numeral: corresponds to protection of equipment against
penetration of solid objects and protection of persons against direct contact with
live parts.
Protection of persons
Non-protected.

Protected against the


penetration of solid objects
having a diameter greater than
or equal to 50 mm.

Protected against direct


contact with the back of the
hand (accidental contact).

Protected against the


penetration of solid objects
having a diameter greater than
or equal to 12.5 mm.

Protection of equipment

0
1

Non-protected.
Protected against vertical
dripping water (condensation).

0
1

Protected against direct


finger contact.

Protected against dripping


water at an angle of up to 15.

Protected against the


penetration of solid objects
having a diameter greater than
or equal to 2.5 mm.

Protected against direct


contact with a 2.5 mm
diameter tool.

Protected against rain at an


angle of up to 60.

Protected against the


penetration of solid objects
having a diameter greater than
1 mm.

Protected against direct


contact with a 1 mm diameter
wire.

Protected against splashing


water in all directions.

Dust protected
(no harmful deposits).

Protected against direct


contact with a 1 mm diameter
wire.

Protected against water jets in


all directions.

Dust tight.

Protected against direct


contact with a 1 mm diameter
wire.

Protected against powerful jets


of water and waves.

Protected against the effects of


temporary immersion.

Protected against the effects


of prolonged immersion under
specified conditions.

K9CE31000

Schneider Eletric

Design guide

Protection of equipment
Non-protected.

2nd characteristic numeral: corresponds to


protection of equipment against penetration of water
with harmful effects.

85

Design guide

Designing with I-LINE II busbar


trunking system

I-LINE II
5 - Checking the rating with respect to allowable voltage drop.
The voltage drop between the start and all points of use must not be greater than
the values in the table below:
Installation supplied by:

Lighting

Other use

Low voltage public distribution network

3%

5%

High voltage distribution network

6%

8%

The voltage drop of I-LINE II busbar trunking system with concentrated load can be
found in page(82-83). and also can be calculated using the following formular:
u = k x 3 x (R1 cos + X1 sin) x Ib x L
where
u

the composite voltage drop of the system (V)

R1 and X1

the mean resistance and reactance values of the system ( /m)

Ib

the current of the circuit being considered (A)

the length of the system being considered (M)

cos

the load power factor being considered

the load distribution factor

Design guide

Power

Loads

If the voltage drop exceeds the allowable limits, choose the next rating up.
Re-check the voltage drop of the new rating.

86

Schneider Eletric

K9CE31000

Design guide

Designing with I-LINE II busbar


trunking system

I-LINE II
6 - Checking the rating and choice of circuit breaker with respect to short-circuit withstand current
Short-circuit current withstand is shown in page(82-83).
This value must be greater than the prospective short-circuit current, at all points of
the installation.
Calculate the short-circuit current value at the worst case points.
Check the chosen rating allows the busbar trunking to cope with this short-circuit
current.
If this is not the case, there are 2 possible solutions:
choose a higher rating busbar trunking and re-check,
provide a peak current limiting protection system upstream of the busbar trunking.


7 - Protecting against busbar trunking overloads.

Circuit breaker protection allows the I-LINE II busbar trunking to be used at full
capacity because the standardised nominal current In of the circuit breaker is
In Inc/K2 where K2 = 1.
Protection using gG (gI) fuse:
determine the standardised nominal current In of the fuse such that: In Inc/K2
where K2 = 1.1.
choose the standardised rating In that is equal to or just lower.
Check the following condition: In Ib x k1 = Iz.
If this condition is not met, choose the busbar trunking with the next rating up.
Note: using gI fuses for protection means reducing the busbar trunkings allowable
current.

K9CE31000

Schneider Eletric

87

Design guide

To allow for extensions, the busbar trunking is generally protected at its nominal
current Inc (or its allowable current Iz if the ambient temperature coefficient k1 is
applied).
Circuit breaker protection:
adjust Ir of the circuit breaker such that:
Iz = Ib x k1 Ir Inc

Harmonic currents

Design guide

I-LINE II
Origin of harmonic currents

Harmonic currents are caused by non-linear loads connected to distribution


systems, i.e. by loads that draw current with a waveform different that that of the
voltage that supplies them.
The most common non-linear loads are equipment including rectifiers, fluorescent
lighting and computer hardware.
In installations with a distributed neutral, non-linear loads may cause significant
overloads in the neutral conductor due to the presence of third-order harmonics.

DD210679

Harmonic order
The order is the ratio
between the harmonic
frequency fn and the
fundamental frequency
(generally the power
frequency, 50 or 60 Hz):
n = fn/f1
By definition, the
fundamental f1 is order 1
(H1).
Third-order harmonics (H3)
have a frequency of 150 Hz
(when f1 = 50 Hz).

Estimating THD (total harmonic


distortion)

The presence of third-order harmonics depends on the applications involved.


It is necessary to carry out an in-depth study on each non-linear load to determine
the level of H3:
ih3 (%) = 100 x i3 / i1
i3 = rms current of H3
i1 = rms current of the fundamental
Assuming that H3 is preponderant among harmonics, the THD is close to the value
of H3 (ih3(%)).

PD202029

PD202028

Design guide

There are two decisive factors:


the types of connected devices:
disturbing loads: fluorescent lighting, computer hardware, rectifiers, arc furnaces,
etc.,
non-disturbing loads: heating, motors, pumps, etc.,
the ratio between the two types of disturbing loads.

Workshops

Offices

Low probability of harmonics


THD 15%.

High probability of harmonics


15 % < THD 33%.

Mix of disturbing loads (computers,


UPSs, fluorescent lighting) and nondisturbing loads (motors, pumps,
heating).

88

Schneider Electric

Numerous disturbing loads (computers,


UPSs, fluorescent lighting).

K9CE33000

Harmonic currents

Design guide

Ph1 Ph2 Ph3

Fundamental frequency: ih1 (50 Hz)

i h1

i h1

Ph1 Ph2 Ph3

i h1

i h1

i h1

i h3

i h3

i h3

i h3

i h3

i h3

DD210680

No current in the neutral.


The conductors are correctly sized.

i h1

Effects of harmonics on I-LINE II busbar


trunking

DD210681

I-LINE II

Fundamental frequency: ih1 (50 Hz) and 33% of


H3
Abnormal temperature rise in the conductors caused
by current at a higher frequency in the phases (skin
effect) and current in the neutral caused by summing
of the H3 harmonics.

DD210683

i h3

Busbar-trunking selection
THD 15 % 15 % < THD 33 % THD > 33 %

Busbar trunking Rating (A)

800

630

400

I-LINE II

800

1000

800

630

I-LINE II

1000

1350

1000

800

I-LINE II

1350

1600

1350

1000

I-LINE II

1600

2000

1600

1350

I-LINE II

2000

2500

2000

1600

I-LINE II

2500

3000

2500

2000

I-LINE II

3000

4000

3000

2500

I-LINE II

4000

5000

4000

3000

I-LINE II

5000

6000

5000

4000

I-LINE II

6000

Example. For a total rms current of 2356 A, (estimation based on power drawn by loads,
including harmonics), the operational current is 2500 A.
THD is estimated at 30%. The appropriate trunking is I-LINE II 3000 A.

For more information on harmonics

See the Cahier Technique publications on the Schneider Electric web site:
www.schneider-electric.com

K9CE33000

Schneider Electric

89

Design guide

Reduce the current


density in ALL conductors
by using appropriately
sized trunking.

i h3

i h3

i h1

i h3
i h3

i h3

i h1
i h3

i h1

i h1
i h3

Ph1 Ph2 Ph3

i h3

i h1
i h3

Fundamental frequency:
ih1 (50 Hz) and
33% H3

i h1

i h3

Ph1 Ph2 Ph3

i h3

DD210680

The only effective solution

Design guide

Fire resistance

I-LINE II
As required by standards, I-LINE II busbar trunking complies with:
1 - material resistance to abnormal temperatures,
2 - flame propagation resistance,
3 - fire barrier function when going through a partition wall,
4 - conservation of all circuits for 0.5~2 hours in a fire resistance sheath.

Definition of tests

1 - Insulating material resistance test to abnormal


temperatures
Objective
To check a material will not be suspected as being the origin of a secondary fire
outbreak.
As defined in standards 8.2.13 IEC 60439-2 and IEC 60695-2-10 to -2-13.
Method
Application of an incandescent wire for 30 seconds on the insulating materials in
contact with live parts.
Result criteria
The specimen is considered to have passed the incandescent wire test if:
if there is no visible flame and no sustained incandescence,
the specimens flames and incandescence go out within 30 seconds of the
incandescent wire being removed.

2 - Flame propagation resistance test


Objective
To check a busbar trunking will not create secondary fire outbreaks.
As defined in standards 8.2.14 IEC 60439-2 and IEC 60332 part 3.
Method
Application of a flame for 40 minutes on a straight length of busbar trunking
whose centre is located 2.5 metres from the edge of the burner.

Design guide

Result criteria
The specimen is considered to have passed the test if:
combustion does not occur,
the maximum extent of the burned part (external and internal) of the busbar
trunking does not go beyond 2.5 metres above the lower edge of the burner.

90

Schneider Electric

K9CE35000

Design guide

Fire resistance

I-LINE II
3 - Fire barrier test through a partition wall
Objective
To check a busbar trunking will not propagate a fire from one room to another by
crossing a fire barrier wall for 60, 120, 180, or 240 minutes.
As defined in standard EN 1366-3.
Method
The fire barrier busbar trunking section to be tested is placed in an oven which
executes a standardised temperature-time curve.
Result criteria
The specimen is considered to have passed the test if:
there are no flames behind the fire barrier,
there is no smoke or gas behind the fire barrier (not requested by the standard;
can appear as a remark in the test report),
the temperature rise of the casing behind the fire barrier does not exceed 180C.

4 - Conservation of all circuits in fire conditions test


Objective
To check all the busbar trunkings electrical circuits are preserved in fire conditions.
As defined in standard DIN 4102 part 12.
Method
Its entire length inserted, the busbar trunking is taken as a specimen in a fire
resistance sheath.

Design guide

Result criteria
The specimen is considered to have passed the test if:
conductor continuity is preserved,
there is no short-circuit between conductors.

K9CE35000

Schneider Electric

91

Design guide

Measurements and metering


Transparent Ready units

I-LINE II

DD205669

The Transparent Ready concept

Transparent Ready is a simple solution to access information (status,


measurements, etc.) available from your electrical distribution equipment
(transformers, switchboards, busbar trunking).
This information can be accessed from any PC connected to your Ethernet network
via a simple Web browser (e.g. Internet Explorer). No other software is required.

Design guide

DD205668

Transparent Ready can make your company more competitive by:


reducing operating costs
optimising equipment performance
improving the reliability of the electrical power supply.

Customer needs for measurements and


metering

In all non-residential buildings, the need for sub-metering exists and is growing
underthe combined effects of:
national and supra-national energy regulations,
the need to reduce overheads and production costs,
the allocation of energy expenditures to cost centres,
the outsourcing of operations tasks to specialists.
Operators must therefore have access to reliable pre-processed information in
order to:
identify areas for potential savings,
model building energy flows and anticipate evolving needs,
optimise energy supply and consumption.

92

Schneider Electric

K9CE34030

Measurements and metering


Transparent Ready units

Design guide

I-LINE II
I-LINE II and Transparent Ready

I-LINE II offers measurement and metering units.


They are equipped with mounting plates designed to receive a PowerLogic
PM810 Power Meter, a Compact NS circuit breaker and the associated current
transformers and contactors.
These units are connected to Transparent Ready solutions using a Modbus
communication network.
An automatic PowerLogic gateway (EGX400) provides the link between Modbus
and Ethernet TCP/IP networks.

DD205665

Design guide

Please consultant the local office of Schneider Electric for more details.

K9CE34030

Schneider Electric

93

Direct current

Design guide

I-LINE II
Determining the DC current value

Thermal effect

Rule
The total power dissipated as heat must remain constant in the duct:
Pac = Pdc
Where:
the power dissipated as heat: Pac = 3 x R x Iac where:
R= resistance of a conductor,
Iac = conductor rms current,
the dissipated power for 4 conductors: Pdc = 4 x R x Idc where:
Idc = direct current.

Selection table

DD210893

1 source
Case of 2 conductors in parallel for the + and 2 conductor in parallel for the (only
1 circuit in the busbar trunking):

Design guide

DD210894

2 sources
Case of 1 conductor for the + and 1 conductor for the (2 circuits possible in the
same busbar trunking):

94

Busbar trunking rating (A)

1 source

2 sources

800

1386

693

1000

1732

866

1250

2165

1082

1350

2338

1169

1600

2771

1385

2000

3464

1732

2500

4330

2165

3000

5196

2598

3200

5542

2771

4000

6928

3464

5000

8660

4330

6000

10392

5196

Schneider Electric

K9CE34010

Installation guide

96

Horizontal distribution

99

Rising mains

100

Reception, handling and storage

102

Testing and Commissioning

104

Maintenance

108

Installation guide

Layout advice

K9CE44000

Schneider Electric

95

Installation guide

Layout advice
Positioning and supports

I-LINE II

Edgewise passage through wall

Flatwise passage through wall

Installation guide

H: the width of I-LINE II busway in Page

96

Schneider Electric

K9CE41000

Installation guide

Layout advice
Positioning and supports

I-LINE II
A support point as close as possible to the connections is needed because
transformers, generator sets and switchboards must not support the weight of the
busbar trunking.
In some industries, for service continuity reasons, transformers may be replaced
quickly. The busbar trunking must be able to support itself.

Edgewise horizontal installation

The maximum recommended distance between supports is 3 metres.

3000

The recommended distance between supports is 2 metres. In addition, a support


must be placed at 300 or 400 mm from the joint block axis.

Example of spreading out supports

Plan for a maximum distance between supports of 3 metres.

Installation guide

Flatwise horizontal installation

K9CE41000

Schneider Electric

97

Layout advice
Positioning and supports

Installation guide

I-LINE II
Defining the layout, dimensions to be
provided
DD210924

The position of the joint block with respect to the transformer axes and switchboard
edges (defined in the Installation guide).

Edgewise installation

Flatwise installation

DD210927

Distance of the busbar trunking from


the wall

H: the width of I-LINE II busway in Page

Installation guide

Edgewise installation
DD210925

Distance between busbar trunking


(without plug-in units)

(1) Provide 2 times the height if the joint block must be fitted from the top.
Direction of fitting joint blocks.

DD210926

Flatwise installation

Direction of fitting joint blocks.

98

Schneider Electric

K9CE41000

Horizontal distribution
Checking and compensating for
expansion

Installation guide

I-LINE II
DD202446

Expansion only poses a problem when:


the runs are made up of long straight sections without elbows and the two end
are fixed.
when the busbar trunking passes through an expansion joint between two
buildings.
No expansion joint is needed in rising mains once the spring hangers are
installed.
Electrical busbar trunking can be subjected to a multitude of load variations during
its service life (e.g. day / night, summer / winter) which cause temperature rise
differences and thus variable expansions.
To absorb expansion in a I-LINE II busbar trunking, a specific section must be
used: the expansion joint.

Expansion joint

Horizontal runs

If the busbar trunking length is greater than 30 metres, provide for expansion joints
and appropriate blocking means. The ends and, in some cases, the centre of part
runs must be blocked in order to direct the extensions towards the expansion
joints.

DD210998

Layout of expansion joints and blocking means for the following busbar
trunking lengths:
0 to 30 metres:

DD210999

31 to 60 metres:

DD211012

Installation guide

DD211000

61 to 90 metres:

Building A

Building B

Blocked fixing supports,


Expansion joint,
Direction of expansion.

K9CE41000

Schneider Electric

99

Installation guide

Rising mains
General

I-LINE II
PD202319

I-LINE II enables power distribution to each floor of multi-storey buildings (office


buildings, hotels, hospitals, etc).
In this application, I-LINE II retains all its construction principles:

Installing a rising main


1 Installation principle
Installation at each floor of:
a 4 or 6 feet riser section,
a made to measure transport section to go through the floor slab,
a busbar trunking support,

2 Installation feed
The installation feed is achieved using either a cable end box or by a flanged end
connection to an electrical distribution switchboard.
3 Busbar trunking supports
The supports fix the vertical run section to the building structure. a floor slab
support. It can be fixed to either the wall, to a wall bracket or directly to the floor,
This type of fixing support has the following advantages:
fitting to either the wall, to a wall bracket or directly to the floor,
spring adjustment to ensure distribution of the load at each floor,
absorption of building stresses with respect to the busbar trunking (expansion,
vibration, etc) thanks to the springs.

4 Plug-in units

Installation guide

All I-LINE II plug-in units can be mounted vertically.

100

Schneider Electric

K9CE45000

Installation guide

Rising mains
General

DD210960

I-LINE II
Positioning the neutral

The busbar trunking must be positioned with the neutral on the left when facing to
the busway and plug-in units.

Positioning the joint

It is important the joint block is not positioned in the floor slab or in spring hanger.
We recommend you provide for a distance of:
700 mm between the floor and the joint block axis to be able to install the spring
hanger (considering 100mm curb).
300 mm between the upper joint block and the ceiling to allow the busbar
trunking to be boxed-in.
DD210961

Positioning the plug-in units

The riser sections are fitted with 1/2/3 plug-in openings in 4/6/10 feet.
.

Positioning the multi runs

Installation guide

Positioning the multi runs according to the interval requirement of the plug-in units.
For example:

K9CE45000

Schneider Electric

101

Installation guide

Reception, handling and storage

I-LINE II
This document contains practical information, lays out the general
recommendations (as a complement to the installation regulations) and specifies
the basic instructions that must be respected when handling and storing Schneider
Electric I-LINE II busbar trunking system.
The purchasers engineering, installation and operating staff must become
acquainted with this document and become familiar with the appearance and
characteristics of each of the I-LINE II busbar trunking systems components.
Appropriate planning and coordination between the different job functions is
indispensable for ensuring an efficient installation of the equipment.
Each I-LINE II busbar trunking system is carefully inspected and packaged at the
assembly plant.
The entire system is checked both structurally and electrically.
At the end of inspection, the busbar trunking system is prepared for shipping.
Each section is packed to guarantee easy handling before its installation.
The catalogue number is written on each shipping unit.
Warning
RISK OF ELECTRIC SHOCK, BURNS OR EXPLOSION
Protect the equipment against all contact with water, salt, concrete and other
corrosive surroundings both before and during installation.
Outdoor equipment is not resistant to bad weather until after it has been fully and
correctly installed.
Do not sit or walk on the equipment.
If these instructions are not respected, the equipment may deteriorate leading to a
risk of serious or mortal injury.

Reception

Upon reception, check the information on the shipping note corresponds to the
equipment received to ensure all of the order has been received and shipped.
Complaints concerning missing components or other errors must be sent in writing
to Schneider Electric within 30 days from the date the shipping item was received.
If no complaint has been received within 30 days from the date the shipping
item was received, Schneider Electric will no longer be responsible for repairs or
replacements that may be required.

Installation guide

Upon reception, check the various units of the busbar trunking system immediately
to identify any damage that has occurred during transport.
If there is observed or suspected damage, file a claim immediately with the carrier
and inform the nearest Schneider Electric office.

Handling

Handle I-LINE II products with the greatest of care to avoid damaging the internal
components of the system and to avoid changing the external appearance of the
various parts, as well as the bar ends (connection terminals).
The busbar trunking must be constantly supported by independent means, in
such a way its weight is not resting on the top of the transformers or distribution
switchboards.
The distance between these support means must not exceed 3 metres.
Avoid exposing the busbar trunking to twisting, embossing or impacts, and all other
actions likely to causing damage.
Ensure the handling equipment available at the site of installation is suitable for
handling busbar trunking. In particular, check the lifting capacity of the crane or the
other lifting equipment to be used.

102

Schneider Electric

K9CE51000

Installation guide

Reception, handling and storage

I-LINE II
Take great care when unpacking the equipment:
use a nail-head puller when unpacking wooden crates,
if hauling the busbar trunking with a crane, use Nylon slings to spread the weight
of the unit being lifted,
if using cables, insert a spacing means to avoid damaging the busbar trunking,
if using a forklift truck, position the busbar trunking on the forks in such a way the
weight is evenly distributed.
1 - Cut the strapping holding the packaging case using suitable cutting tools.
2 - Use suitable tools to remove the strengthened steel packaging at each end of
the busbar trunking.
Take care not to damage the steel box so as not to damage the busbar trunking.
Avoid the use of objects with sharp edges when lifting the busbar trunking.
3 - Dispose of all used packaging in an appropriate way.
Never drag the busbar trunking along the floor. Do not use the end bars to lift
sections of the busbar trunking.

Protection against humidity during


storage

If the busbar trunking is not installed and commissioned immediately, leave it in


the original I-LINE II packaging and store it in a clean and dry place at a uniform
temperature.
The busbar trunking must not be stored outside. However, if outside storage
is necessary, cover the busbar trunking in such a way as to protect it from bad
weather and to avoid contact with the elements.
Temporary electrical heating must be provided for underneath the covering means
to prevent condensation.
The supplied heat must be of suitable temperature and uniformly distributed
underneath the covering means.

Installation guide

Outdoor busbar trunking is not resistant to bad weather until after it has been fully
and correctly installed.
During installation, take particular care to protect rising mains from humidity arising
from unfinished roofs, walls and other similar elements.

K9CE51000

Schneider Electric

103

Installation guide

Testing and commissioning

I-LINE II
All the operations described below are given for indication only. Under no
circumstances can they be used to substitute the installation companys own
procedures and engage Schneider Electrics responsibility.

Scope

High power busbar trunking, transformer-switchboard links.


Required tools
multimeter,
500V megger,
roto-phase.

Prerequisites

If need be, the old equipment has been removed from the premises.
The new equipment has been manoeuvred into the premises where it is to be
installed by the installation contractor.
The equipment has been installed by the installation contractor in accordance
with manufacturers recommendations.
The equipments installation diagram, connection diagram and assembly results
sheet are available for the commissioning engineer.

De-energising the installation and making it safe

The works manager is responsible for worksite safety and must ensure the
installation is de-energised and made safe in accordance with safety rules before
any inspection or measurement is performed.

Equipment checking, positioning and


identification

After the installation contractor has positioned, assembled and connected the
busbar trunking in accordance with the supplied installation, assembly and
connection diagrams, and using the recommended tools and handling equipment,
the following characteristics must:
be noted,
be checked for compliance with respect to the details shown on the drawing.
Brand

Busbar trunking rating:

Equipment type:

Serial number:

Reference:

Date of manufacture:

Transformer power:

Source circuit breaker


(busbar trunking
protection):

General visual inspection


Installation guide

The equipment has been chosen according to its electrical environment (rating and
protection adapted to operating conditions).
The following points do not require checking.
Points concerning reception, storage and handling
No signs of:
shock (which may deteriorate internal insulation: conductor insulation on straight
lengths or at the tap-off points or joint blocks),
humidity or oxidation (equipment stored outside should have been covered with a
plastic sheet, sheltered from humidity, dirt and dust),
firms label defining the products characteristics.

104

Schneider Electric

K9CE36000

Installation guide

Testing and commissioning

I-LINE II
Points concerning installation and fittings
Assembly compliance with the specifications of the installation drawing, service
instructions and the catalogue:
no busbar trunking twisting,
positioning and distance of the busbar trunking with respect to the building,
fixings, compliance of the between centres distance of the equipment for flat or
edgewise, horizontal or vertical distribution,
clamps, not fully blocked to allow movement due to longitudinal forces ,
presence of expansion sections if necessary.

Checking power connections

General visual inspection

Check the number of connection parts and their cross-sections for each conductor
(see Installation guide).
Check insulation distances between 2 conductors and between conductors and
metal panels.
Check the tightening torque of bolts not fitted with torque nuts. For bolts fitted with
torque nuts, check the head has broken-off.

Check the bolt length exceeding the nut (10 mm); some bolts may have been
removed and then put back, but left untightened.
Mark each tightened nut using indelible varnish. As well as a means of selfinspection to ensure correct tightening torque, it also allows any untightening to be
identified.

Bolt

Tightening torque

HM16

16 mdaN

HM14

12 mdaN

HM12

7 mdaN

HM10

5 mdaN

The results of all these checks must be noted on the results sheet by the
installation contractor.

Checking insulation between live conductors

These measurements and checks can only be performed if:


each link is disconnected by an isolating device,
each link is disconnected from the upstream transformer, with the main circuit
breaker upstream of the LV switchboard unplugged and in the open position.
Test means: 500V DC megger (DC to avoid capacitive currents)
Measurements: 6 measurements between live conductors (between phases and
then between each phase and neutral).
LV circuit insulation value (U < 500 Volts): 1000 ohms/volt of nominal voltage
(IEC 60 439-1) allowed.
In all cases, the insulation resistance must not be less than 0.5 M for each link
(operating device).
Note: I-LINE II busbar trunking is given for U = 1000V and Ri = 1 M (value to be
taken into account for all elements: transport and accessories, distribution).
K9CE36000

Schneider Electric

105

Installation guide

Class 8-8 nuts and bolts (M8 on LV switchboard side, see Commissioning Guide
for Schneider Electric LV Switchboards).

Installation guide

Testing and commissioning

I-LINE II
Checking the earth network and locks

Earth network

General visual inspection


Check:
the galvanised steel casing sides are earthed (note: this depends on the earthing
system),
connection quality,
cable cross-section,
there are no loose metal parts (washers, screws) in the plug-in units.
Note: the results of these checks must have already been noted on the results
sheet by the installation contractor.
Checking insulation between live conductors and earth
Following this check, each link must be reconnected to the upstream transformer
(use the 2nd available 6 daN.m torque bolt heads).

Test means: 500V DC megger (DC to avoid capacitive currents)


Measurements: between each phase or neutral(1) and earth (the casing if it is
connected to earth).
LV circuit insulation value (U < 500 V): 1000 of nominal voltage (IEC 60 439-1)
allowed.
In all cases, the insulation resistance must not be less than 0.5 M for each link
(operating device).
Note: I-LINE II busbar trunking is given for U = 1000 V and Ri = 1 M (value to be
taken into account for all elements: transport and accessories, distribution).
(1) No neutral insulation if the earthing system is such that the neutral is connected to or used
as the earth.
Caution: In this case, once the transformer has been reconnected (star secondary), the phaseearth measurement is the winding resistance.

PE protective circuit equipotential

Reference: IEC 60 439-1:


Check PE protective circuit continuity by visual inspection and random continuity
testing.
The previously performed phases-PE insulation test must have been compliant.
Test means: ohmmeter.

Locks

Installation guide

To protect personnel by not allowing access to live parts through the use of locks.
Only concerns key operated safety locks.

Checking connections and auxiliary


testing

106

Check not relevant to busbar trunking.

Schneider Electric

K9CE36000

Installation guide

Testing and commissioning

I-LINE II
De-energised equipment operating tests

Checking source circuit breaker protection settings

Compliance check in accordance with the installation drawing specifications:


Imax thermal,
In magnetic.
Note: this check is only to be performed if the busbar trunking is commissioned
at the same time as the transformer: the source circuit breaker protection setting
checks are related to transformer commissioning.
Check not relevant if the transformer has already been commissioned.
If this check is successful, the busbar trunking can be commissioned and
the energised operating tests performed with the appropriate protective
equipment

Commissioning and energised


equipment operating tests

NOTE: commissioning can only be carried out by personnel with appropriate


authorisations.
Preliminary operation: energising the off-load transformer.
Closing the source circuit breaker.

Checking phase order

Objective: to detect, in order to correct, an inversion of the phases or neutral


amongst the busbar trunkings 4 incoming and outgoing connections with respect
to the transformer output.
Test means: roto-phase or 3-phase harmonic analyser.
If busbar trunking energising is successful, a progressive start-up of the factory
must be requested to definitively validate commissioning.
If unsuccessful, the previous checks must be carried out again to try and
locate the fault. Before undertaking this, the equipment must once again be
made safe.

Final putting into service test

This test is performed once the busbar trunking has been energised. The
progressive start-up of loads will highlight any undesirable phenomena due to the
increased average load.
Real life operating test
Once the high power busbar trunking has been energised, the other busbar
trunking must be gradually put into service starting with those furthest from the
load, then each load itself, those with high pull-in currents, then the lighting,
contactors, heating, motors, etc.

The test simply consists of checking correct busbar trunking operation according
to:
the average number of machines in operation,
the load variation of each individual load,
the simultaneous operation of machines (superimposing of peaks).
If everything is in order, the busbar trunking is declared in-service.
Testing is completed.

K9CE36000

Schneider Electric

107

Installation guide

There must not be excessive vibration, and no sparkovers should be observed.

Installation guide

Maintenance
Straight lengths

I-LINE II
Danger

RISK OF ELECTRIC SHOCK, BURNS OR EXPLOSION


The installation, operation and maintenance of the equipment must only be
carried out by qualified electrical maintenance staff. This document must not be
considered as being a sufficient means for allowing non-qualified staff to undertake
the operation and maintenance of the equipment.
Cut the electrical supply to the busbar trunking before installing, removing or
working on the equipment.
Always use a suitable nominal voltage detection means to confirm the supply has
been cut.
Effective use of the equipment requires the implementation of appropriate
handling, installation, functioning and maintenance operations.
If these instructions are not respected, there is a risk of serious injury or
death.

Warning

RISK OF DAMAGING THE EQUIPMENT


Hydrocarbon aerosols and aerosols using a hydrocarbon base may cause the
deterioration of certain plastics.
Before using certain products to clean, dry or lubricate the different components
during installation or maintenance, consult your nearest Schneider Electric office.
If these instructions are not respected, the equipment may deteriorate
leading to a risk of serious injury or death.

Straight lengths

I-line II busbar trunking has been designed for minimum maintenance.


Inspect the busbar trunking once a year, or after all serious incidents concerning
electrical short-circuits or earthing faults.
Carry out the following maintenance procedures:
meticulously inspect all visible electrical connections and joints. Do not remove
joint covers. Check the nuts and bolts are correctly tightened,
use a torque wrench to check bolt tightening torques.
The tightening torque is marked on the connection block and the following values
must be respected:
Bolt

Tightening torque

HM 16

16 mdaN

HM 14

12 mdaN

HM 12

7 mdaN

HM 10

5 mdaN

Installation guide

If one of the joints or terminals is highly discoloured, corroded or pitted, or shows


signs it has been exposed to high temperatures, the material concerned must be
replaced with new factory mounted material. Consult your local Schneider Electric
office for all replacements,
ensure all mechanisms are in good working order.
Lubricate the moving parts of the various mechanisms if necessary. Similarly,
remove all excess lubrication to avoid undesirable foreign bodies from gathering,
check the insulation resistance before re-energising the busbar trunking.
It is recommended that resistance measurements are recorded. If these values
decrease significantly over time, it means deterioration is underway.
Carry out an insulation resistance test in compliance with the instructions given in
the testing and comissioning procedure section.
Re-energise the equipment in accordance with the instructions given in the testing
and comissioning procedure section.

108

Schneider Electric

K9CE52000

Installation guide

Maintenance
Recycling

I-LINE II
After having performed all the necessary inspections and repairs mentioned above,
it may be desirable to carry out infrared temperature measurements on all the
electrical connections. This operation must be done once the busbar trunking has
been re-energised and reached a stabilized temperature.
Responsibility
Schneider Electric declines all responsibility for maintenance carried out in a
non-compliant way with respect to specifications or installation regulations, for
inappropriate storage conditions, for inappropriate product environments (chemical
and ambient conditions, atmospheric conditions, etc.), for the incorrect use of the
products, and for the non-respect of installation and/or connection procedures.

Distribution plug-in units

Contact between busbar trunking and plug-in units.

Busbar trunking contacts consist of spring silver plated contact jaws to ensure
optimum contact quality. The contacts do not use plastic for their support or
transmission of force.
They are connected to the live conductors of the run at the plug-in outlets. Silverplated copper conductors are used at the place of contact.
These devices are maintenance-free.

Cable connection

Cable connection of the feeders are via terminals or lugs.


As with all screw connections, it is recommended that tightening torque be checked
one year after installation and then to space-out the checks.

Protection switchgear

For all devices fitted in Canalis tap-off units, the manufacturers recommendations
must be complied with.

Checking appearance

It is recommended the external cleanliness of the tap-off units be checked yearly


to remove dust, water and oil deposits, may affect thermal cooling and all other
conductive bodies from the sensitive zones.
Check for signs of shock which may affect the protection degree.

Recycling busbar trunking

I-LINE II busbar trunking can be reused. I-LINE II busbar trunking is designed for a
long service life and can easily be dismantled, cleaned and reused.

All I-LINE II products are designed for safe end-of-life recycling. PVC, on the other
hand, requires neutralisation of the hydrochloric acid produced using lime and
generates dioxins that are extremely toxic.

I-LINE II helps conserve natural resources

Example:
1 kg of PVC generates 1 kg of waste.

K9CE52000

The depletion of raw materials (copper, plastics, etc.) is one of our ongoing
concerns.
For this reason, we have optimised the used of all materials used to make our
busbar trunking.
Reduction of dangerous or polluting materials. We design our products to meet
future worldwide directives.
Reduction in the weight of insulating materials.
Reduction in the use of plastics for improved fire performance: less energy
released during combustion, thereby limiting propagation and facilitating extinction
(lower calorific value).

Schneider Electric

109

Installation guide

All packaging materials can be recycled (cardboard or recyclable polyethylene


film).

Schneider Busway (Guangzhou) Limited


Postal address
85 Jun Ye Lu, Northern Part of Eastern Section
of Guangzhou Economic & Technological
Development District, Guangzhou
510530, PR China

As standards, specifications and designs change from time to time, please ask for confirmation
of the information given in this document.
Printed on recycled paper