Professional Documents
Culture Documents
(PS)
1
www.hariff.co.id
2
Power System
(PS)
Power System
Menyediakan supply power untuk semua
peralatan listrik. Keterbatasan power tidak lagi
menjadi masalah untuk memiliki suatu sistem
dan jaringan yang handal.
01
02
03
04
05
06
07
System APR48 3G
Outdoor Floating
Key Features
System Overview
48V integrated floating systems up to 18kW
Hariff Power System range of DC power systems
is designed for telecommunications network
applications requiring compact, efficient and flexible
DC power supplies.
Typical Applications:
4
Power System
(PS)
Specifications
Input
AC Supply
Frequency
Power Factor
Efficiency
up to 92%*
Output
DC Output Voltage Range
40 -58V
Up to 18kW
Environmental
Operating Temperature Range
-25C to +50C*
Mechanical
Dimension H, W, D
Indoor
Outdoor
Weight
100kg
System
System Controller
SC100/SC200
Option
AC Distribution
DC Distribution
Battery Distribution
Software
DC Tools
Certifications
All products comply with International Standards. Contact your local Powerware DC representative for details on the specific product
versions available with these safety and EMC approvals:
China
MII
Europe
CE
Australia/New Zealand
C-tick
Indonesia
QA RDC Telkom
APR48 Outdoor
Key Features
System Overview
48V integrated charge discharge systems up to
18kW. Hariff Power System range of DC power
systems is designed for telecommunications
network applications requiring compact, efficient
and flexible DC power supplies.
These DC power systems use Eaton APR-48
rectifier modules and include an integral AC and DC
distribution with flexible combinations of fuses and
MCBs, and an SM-45 system controller. Low voltage
disconnect (LVD) options are also available.
Intelligent system management features include
battery temperature compensation, fast charge,
battery current limit, automatic equalize charging
and automatic battery condition monitoring.
Typical applications are providing 48V standby power
for end-of-row and centralized architecture such
as local and central office switches and other large
6
Power System
(PS)
Transmission terminals.
Local and central office switching.
Specifications
Input
AC Supply
Frequency
50/60Hz (nominal)
Other options available depending on system capacity.
Power Factor
Efficiency
up to 90%*
Output
DC Output Voltage Range
40 58V
Up to 18kW
Environmental
Operating Temperature Range
-25C to +50C*
Mechanical
Dimension H, W, D
Indoor
Outdoor
Weight
98kg
System
System Controller
SM-45
Option
AC Distribution
DC Distribution
Software
DC Tools
Certifications
All products comply with International Standards. Contact your local Powerware DC representative for details on the specific product
versions available with these safety and EMC approvals:
China
MII
Europe
CE
Australia/New Zealand
C-tick
System Overview
48V integrated floating systems up to 18kW With
Additional 4kW DC to DC Module.
Hariff Power System range of DC power systems
is designed for telecommunications network
applications requiring compact, efficient and flexible
DC power supplies.
8
Power System
(PS)
Specifications
Environmental
Operating Temperature Range
-30C to +70C*
Mechanical
Dimension H, W, D
Outdoor
Weight
96kg
System
System Controller
SM-32/36
Option
AC Distribution
DC Distribution
Software
SM-3x Configuration Software
Certifications
All products comply with International Standards:
Electrical Safety
EN 60950
RF Emmisions
CISPR 22 Class B
RF Immunity
CISPR 24
AC Harmonics
EN 61000-3-2
EN 61000-3-3
RoHS
2002/95/EC
Consumer Safety
CE
indoor type
outdoor type
System Overview
Key Features
10
Power System
(PS)
Specifications
Input
AC Supply
2201P+N+PE
Frequency
50/60Hz (nominal)
Other options available depending on system capacity.
Power Factor
>0.99*
Efficiency
up to 92%*
Output
DC Output Voltage Range
43 60V
Up to 2.4kW
Environmental
Operating Temperature Range
-20C to +70C*
Mechanical
Dimension H, W, D
Indoor
Weight
89kg
Outdoor
Weight
96kg
System
System Controller
SM-32,33,34 & 36
Option
AC Distribution
DC Distribution
11
45RU Cabinet
Intelligent system management features
Web Base and support SNMP Application
Pre-Configured Software
High Power Density (1.2W/cm3)
Fast On-Line Expansion of Rectifiers (Hot-Swap)
High Efficiency and Unity Power Factor
Range of DC distribution configurations
Event Log & Data Log Up to 10.000 entry
Wide AC input voltage range
AC / DC Surge Arrester Protection
Remote monitoring and control
System Overview
48V integrated floating systems up to 92.8kW
Hariff Power System range of DC power systems
is designed for telecommunications network
applications requiring compact, efficient and flexible
DC power supplies.
Typical Applications:
12
Power System
(PS)
BSC
MSC
Specifications
Environmental
Operating Temperature Range
-20C to +50C*
Mechanical
Dimension H, W, D
Indoor
System
System Controller
SC-200
Option
AC Distribution
DC Distribution
Software
ICE & DC tools Configuration Software
Certifications
All products comply with International Standards. Contact your local Powerware DC representative for details on the specific product
versions available with these safety and EMC approvals:
China
MII
Europe
CE
Australia/New Zealand
C-tick
13
Hot Swappable
Remote Monitoring via SNMP option
System Overview
The Hariff Power Inverter with TSI inverter
modular and scalable to capacities up to
75KVA 3 phase, 80KVA dual phase and is easily
configured to your current and future AC
requirements. TSI inverters are available in
either 1500VA (Media) or 2500VA (Bravo) building
blocks.
The TSI Distributed Static Transfer Switch
Technology eliminates the single point of failure
in a traditional inverter design. Unlike hard
transfers between energy input sources the TSI
soft switching method is disturbance free.
The TSI inverter is field upgradeable and its hot
swappable modular design reduces risks caused
by exposing your critical load to an unpredictable
AC source.
There is no need to go to bypass when adding or
changing the capacity of your inverter system.
14
Power System
(PS)
Specifications
DC Input
Nominal Voltage (DC)
48V
40-60V
1680 A
2520 A
Voltage Ripple
2mV
user selectable
AC Output
DC Output Voltage Range
200 - 240V
2500VA/Module Up to 80kVA
0s
0s
Environmental
Altitude above sea
<1500
Ambient temperature
-20 to 50C
Storage temperature
-40 to 70C
Relative humidity
Mechanical
Dimension H, W, D
Indoor
Weight
89kg
System
System Controller
Candid Display
Option
AC Input Distribution
DC Distribution
ByPass System
AC Output Distribution
Certifications
EMC (immunity)
EN 61000-4
EMC (emmision)
EN 55022 (Class B)
Safety
IEC 60950
Cooling
Forced
Isolation
Doubled
RoHS
Compliant
15
Key Features
System Overview
Lusyta CDC 48V integrated systems for 1500, 3000,
and 4500W.
Lusyta (the new energy solutions) providing
a solution will need a power supply for
telecommunication devices. Lusyta based mobile
equipment (mobile device) which can be easily
moved as needed and to areas that are not available
electricity
These CDC lusyta 48V system use Rectifier APR
48 3G, genset, battery, control monitoring, and
containers including fuel tank
CDC Lusyta 48V System are pre-configured for fast
installation and set-up. All system settings are fully
16
Power System
(PS)
Transmission terminals
Specifications
Generator Set
Engines
Yanmar
Output
Capacity
Frequency
50Hz
Output Voltage
220/240Vac
RPM
1500
System
System Controller
DATAKOM/DKG109
Generator
Yanan
Environmental
Maximum Operating Temperature
98C
Mechanical
Dimension H,W, D
10KVA
Battery
Battery Starter
12V
Rectifier
APR 48V 3G
Input
AC Supply
Frequency
50/60Hz (nominal
Other options available depending on system capacity
Power Factor
Efficiency
up to 92%
Output
DC Output Voltage Range
40 - 58V
up to 3.7 kW
Inverter
Asian Electron 350W Pure Sine Wave
Input
DC Input Voltage Regulation
42 - 62V
62V
96%
Output
Output Voltage Regulation
200/220/230/240V RMS 3%
Frequency
50/60Hz 0.05%
17
Specifications
Environmental
Operating Temperature Range
-20C to +50C*
-30C to +70C*
Dimension L, W, H
Weight
1.6Kgs
Control Monitoring
1.
2.
3.
4.
5.
6.
7.
GSM Modem
Interface Controller
Feature
SMS
GPRS
Datalog
Start/Stop Genset (By Timer)
Container
Container 1500W, 3000W, 4500W
Contruction
Fuel Intake
Kompartemen Fuel tank Capacity
800 Liter
Battery
Mechanical
Mechanical Dimension H, W, D
18
Power System
(PS)
19