You are on page 1of 4

Technical Data

Effective October 1, 2014

SC-RPB Universal Source Controllers


with Circuit Breakers
Catalog#

Prepared by

Project

Date

Comments

Type

Overview
The Switched Relay Controllers with circuit breakers are scalable to
any size application. The LCD graphical user interface and keypad
permit programming and monitoring for complete system control
and integration. Each Switched Relay Controller can control up to
48 relays per panel with two discrete inputs for use with occupancy
sensors or other input devices. The Switch Relay Controller family
can be networked with other iLumin Source Controllers to provide
both architectural and non-dimmed control. Each Switched Relay
Controller includes fully populated SWD rated 20 Amp circuit
breakers. Each panel has an onboard Ethernet and RS485 ports
that may be used for ASCII integration to A/V or other third party
systems, a DMX interface for complete system integration and
optional support for up to 24, 0-10V dimming outputs. Variable Relay
Timing Technology automatically senses the optimal time to switch
lighting loads, based on the load attached to each output. This not
only extends the life of the relays but also reduces the switching
impact on the connected loads. Each output provides real-time
Power Metering data available from both the LCD graphical user
interface and via the Ethernet port.

Features
Integrated circuit breakers and relays in a single, space saving
enclosure
Real-time power metering
Single or three phase versions
Continuous duty, thermal magnetic SWD rated breakers for each
circuit
Programming stored in non-volatile memory
Individually replaceable relays with Variable Relay Timing
Technology
RoHS compliant
Up to 24, 0-10V Dimming channels (optional)
30 Amp relays used on all 20A relay cards to extend relay life
Control receptacle loads with Latching Relay

Technical Data

SC-RPB Universal Source Controllers with Circuit Breakers

October 2014

Dimensions

Mechanical

Wall mounted design


Surface, enclosures
Integral 20A breakers
Low voltage input connections
Main Lug Bottom Feed
An LCD graphical user interface and keypad
for ease of programming and configuration.
The interface can be used for programming
single area systems there is no need to use a
PC. The GUI also allows programming of the
astronomical timeclock.
All SC-RPB Source Controllers have RS485
and UDP over Ethernet connections to allow
for control by third party systems (Building
Management System, Audio/Visual, etc.)
through the use of open protocol ASCII
message commands
Two contact closure inputs for integration
with auxiliary equipment and emergency
lighting input
DMX512 input for control by entertainment
systems
Power metering information is available via
UDP over Ethernet through the use of open
protocol ASCII message commands

Programming

Interfacing

(Inches/mm)
SC-RPB 18: 54H X 24W X 6D (up to 18 relays)
SC-RPB 30: 76H X 24W X 6D (up to 36 relays)
SC-RPB 42: 90H X 24W X 6D (up to 48 relays)

24 in.
(609.6 mm)

6 in.
(152.4 mm)

54 in. (1371.6 mm)

Features

24 in.
(609.6 mm)
24 in.
(609.6 mm)

Standards

6 in.
(152.4 mm)

24 in.
(609.6 mm)

Up to 24, 0-10V Dimming channels (optional)

6 in.
(152.4 mm)

(All relays have a 25KA SCCR at 277 VAC)

Latching Relay Ratings:


20A, incandescent 120 VAC
20A, ballast 277 VAC

54 in. (1371.6 mm)

Relay Ratings

76 in. (1676.4 mm)

Non-dim (Switched)

90 in. (2286.0 mm)

Load Types

20A, ballast 347 VAC


Maximum wire size: 8 AWG
1HP @ 120 VAC, 2HP @ 277 VAC

24 in.
(609.6 mm)

Two Pole Relay Ratings:

24 in.
(609.6 mm)

Normally open

6 in.
(152.4 mm)

20A, ballast 480 VAC


Maximum wire size: 8 AWG

www.coopercontrol.com

90 in. (2286.0 mm)

76 in. (1676.4 mm)

1HP @ 120 VAC, 2HP @ 277 VAC

6 in.
(152.4 mm)

(1

Technical Data

SC-RPB Universal Source Controllers with Circuit Breakers

October 2014

Wiring Diagram
Latching Relay Receptacle Control

Low voltage connections for


iCANnet, DMX512, RS485,
Ethernet, Contact Closures,
0-10V Dimming come into
the center top section of
the enclosure
Relay connections
to lighting loads
(conduit may
enter through side
or side top of the
enclosure)

Branch Circuit
Breaker feeds to
relays
Branch Circuit
Breaker direct feed
to loads not
controlled
by relays in the
enclosure
Main Breaker
feeds to the
Main Lugs

Sample System Topology

www.coopercontrol.com

Technical Data

SC-RPB Universal Source Controllers with Circuit Breakers

October 2014

Ordering
SC - 120 - 18 - RPB - 1P - ML - 20 - S - 12 - 3 - HF1
Product

Interior Options

SC = Source Controller

0 = 0, 0-10V Dimming Channels (18, 36, 48)


HF1 = 12, 0-10V Dimming Channels (18, 36, 48)
HF2 = 24, 0-10V Dimming Channels (36, 48)

Voltage
120V, 277V, 347V

Number of Two Pole Relays (Two Pole


Relays count as 2, Single Pole Relays)

Number of Circuits

0-8 = 18 Size
0-18 = 36 Size
0-24 = 48 Size

18, 36, 48
Source Controller Type
RPB = Relay Panel with Breakers

Number of Single Pole Relays


0-18 = 18 Size
0-36 = 36 Size
0-48 = 48 Size

Phase
1P = Single Phase (18 Size Only)
3P = Three Phase

Enclosure/Interior Options

Panel Feed

S = Surface

ML = Main Lugs

Branch Breaker Rating (Amps)


20 = 20 Amps

18 Relay

SC120V-18-RPB-3P-ML-20-S-18-0-0
SC277V-18-RPB-3P-ML-20-S-18-0-0
SC347V-18-RPB-3P-ML-20-S-18-0-0

Switched Relay Controller with 18 - 20A 120V breakers, 3P - 250A Main Lugs and 18 latching relays
Switched Relay Controller with 18 - 20A 277V breakers, 3P - 250A Main Lugs and 18 latching relays
Switched Relay Controller with 18 - 20A 347V breakers, 3P - 400A Main Lugs and 18 latching relays

36 Relay

SC120V-30-RPB-3P-ML-20-S-36-0-0
SC277V-30-RPB-3P-ML-20-S-36-0-0
SC347V-30-RPB-3P-ML-20-S-36-0-0

Switched Relay Controller with 30 - 20A 120V breakers, 3P - 250A Main Lugs and 36 latching relays
Switched Relay Controller with 30 - 20A 277V breakers, 3P - 250A Main Lugs and 36 latching relays
Switched Relay Controller with 30 - 20A 347V breakers, 3P - 400A Main Lugs and 36 latching relays

48 Relay

SC120V-42-RPB-3P-ML-20-S-48-0-0
SC277V-42-RPB-3P-ML-20-S-48-0-0
SC347V-42-RPB-3P-ML-20-S-48-0-0

Switched Relay Controller with 42 - 20A 120V breakers, 3P - 400A Main Lugs and 48 latching relays
Switched Relay Controller with 42 - 20A 277V breakers, 3P - 400A Main Lugs and 48 latching relays
Switched Relay Controller with 42 - 20A 347V breakers, 3P - 400A Main Lugs and 48 latching relays

SC-RP Additional Components

iBarrier
HF1
HF2

Individual Relay Barrier, Voltage and Power Source Separation


Field Installable, 12, 0-10V Dimming Channels (Only supported in the 18, 36 & 48 size panels)
Field Installable, 24, 0-10V Dimming Channels (Only supported in the 36 & 48 size panels)

Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com
Eatons Cooper Controls Business
203 Cooper Circle
Peachtree City, GA 30269
coopercontrol.com
2014 Eaton
All Rights Reserved
Printed in USA
Publication No. ACC140926
October 1, 2014

Eaton is a registered trademark.


All other trademarks are property
of their respective owners.

You might also like