You are on page 1of 12

Technical specification

Submersible pump C 3085, 60 Hz

C 3085
Y/D start
SUBCAB

7G2,5 mm2

VFD Application
NSSHU../3E+St

3x2,5+3x2,5/3E+3x1,5 St

Monitoring equipment
Thermal contacts opening temperature

125 C

Material
Impeller

Cast iron

Pump housing

Cast iron

Stator housing

Cast iron

Shaft

Stainless steel

O-rings

Nitrile rubber

Mechanical face seals

C 3085

Alternative

Inner seal

Outer seal

Carbon/ Aluminium
oxide

Corrosion resistant
cemented carbide/
Corrosion resistant
cemented carbide

Carbon/ Aluminium
oxide

Silicon carbide/ Silicon


carbide

Product

Surface Treatment

Submersible pump for pumping clean water, surface water and waste
water containing solids or fibred material.

All cast parts are primed with a water-borne primer. The finishing coat
is a high-solid two pack paint.

Denomination
Product code

Weight
3085.183

Installation

F, P, S, T, Z

Impeller characteristics

LT, MT, HT

See dimensional drawing.

Option

Process data
Liquid temperature
Depth of immersion
The pH of the pumped liquid
Liquid density
Impeller throughlet

max +40 C
max 20 m
pH 5,5-14

3085.092

Ex. proof design

3085.280

Stainless steel design

3085.290

Stainless steel/ex proof design

3085.980

Industrial design

Warm liquid version on request

max. 1100 kg/m3


See Motor rating table

Motor data

Leakage sensor in stator housing

FLS

Leakage sensor in oil housing

CLS

Other cables
Surface treatment

Frequency
Insulation class

60 Hz
H (+180 C)

Accessories

Voltage variation
- continuously running
- intermittent running
Voltage imbalance between phases
No. of starts/hour

max 5%
Discharge connections, adapters, hose connections and other
mechanical accessories.

max 10%
max 2%

Electrical accessories such as pump controller, control panels, starters,


monitoring relays, cables.

max 30

See separate booklet or www.flygt.com, for further information.

Cable
Direct-on-line start
SUBCAB

Epoxy treatment

Zinc anodes

4G1,5 mm 2
4G1,5+2x1,5 mm2
4G2,5 mm 2
4G2,5+2x1,5 mm2

C 3085
LT-Motor rating and performance
curve
Ex proof version available

Impeller thoughlet, mm

Power factor cos

Starting current, A

Rated current, A

Rated power, kW

Curve/Impeller No

P [kW] / [hp]

2.0
2.5

1.8
1.6

Installation
P

H [m] / [ft]

S
30

460 V, 60 Hz, 3 ~, 1710 r/min


414 2,2

4,5

24,0 0,80 80

Yes

414

2.0

LT
9
8

25
Y/D starting current is approximately 1/3 of D starting current.

7
20

6
5

15

4
10

3
2

414

1
0
0
0

5
50

100

10
150

15
200

250

20
300

25
350

400

450

Q [l/s] / [usgpm]

C 3085

460 V, 60 Hz, 3 ~, 1685 r/min


436 1,6 3,4 15,0 0,82 76
438 1,6 3,4 15,0 0,82 64
440 1,6 3,4 15,0 0,82 64
460 V, 60 Hz, 3 ~, 1710 r/min
434 2,2 4,5 24,0 0,80 76
436 2,2 4,5 24,0 0,80 2,2
438 2,2 4,5 24,0 0,80 2,2
440 2,2 4,5 24,0 0,80 2,2

Ex proof version available

Impeller thoughlet, mm

Power factor cos

Starting current, A

Rated current, A

Rated power, kW

Curve/Impeller No

MT-Motor rating and performance


curve

Yes
Yes
Yes

2.5

434

3
2.0

436

1.5
438

1.0

440

1
H [m] / [ft]
Installation
F
P
S

45

MT
T

40

12

35

10
30
25

Yes
Yes
Yes
Yes

P2 [kW] / [hp]

20
15

8
6
434

10
460 V, 60 Hz, 3 ~, 1720 r/min
438 1,2 2,7 15,0 0,75 64
440 1,2 2,7 15,0 0,75 64
460 V, 60 Hz, 3 ~, 1735 r/min
436 1,7 3,7 24,0 0,74 76
438 1,7 3,7 24,0 0,74 64
440 1,7 3,7 24,0 0,74 64
230 V, 60 Hz, 1 ~, 1705 r/min
438 1,2 7,2 30,0 0,98 64
440 1,2 7,2 30,0 0,98 64
230 V, 60 Hz, 1 ~, 1710 r/min
436 1,8 10,0 47,0 0,94 76
438 1,8 10,0 47,0 0,94 64
440 1,8 10,0 47,0 0,94 64

Yes
Yes

Yes
Yes
Yes

Yes
Yes

Yes
Yes
Yes

436

2
438

440

Y/D starting current is approximately 1/3 of D starting current.

0
0

100

10

15
200

20
300

25

30

400
500
Q [l/s] / [usgpm]

C 3085

Ex proof version available

Impeller thoughlet, mm

Power factor cos

Starting current, A

Rated current, A

Rated power, kW

Curve/Impeller No

HT-Motor rating and performance


curve

P2 [kW] / [hp]
4.5
4.0
3.5

5,0

30,0 0,92 40

Yes

2.5

252

3.0
2.5

2.0

H [m] / [ft]

Installation
P

HT

90

460 V, 60 Hz, 3 ~, 3435 r/min


252 30,

3.0

80
70

Y/D starting current is approximately 1/3 of D starting current.

25
20

60
50

15

40
30
20

10
5

10
252

0
0
0

4
50

6
100

10 12 14 16 18
150

200
250
300
Q [l/s] / [usgpm]

C 3085
Dimensional drawing
All drawings are available as Acrobat documents (.pdf)
and AutoCad drawings (.dwg). Download the drawings
from www.flygt.com or contact your ITT Flygt
representative for more information.
All dimensions are in mm.

LT, P-installation

LT, P-installation

C 3085
LT, S-installation

LT, S-installation

MT, F-installation

MT, P-installation

C 3085
MT, P-installation

MT, P-installation

MT, S-installation

MT, S-installation

C 3085
MT, T-installation

MT, Z-installation

HT, P-installation

HT, S-installation

10

C3085.60Hz.04.02.FIN.EN:12.04 ITT Flygt AB

www.flygt.com

894911

You might also like