You are on page 1of 27

01.4SP.

00003
Power/Vac Circuit Breaker Spare Parts Catalog
Equipped with ML-17 Mechanism
5kV & 15kV, (1200A, 2000A, 3000A, 3500A, & 4000A), up to 63kA

Powered by Safety

Power/Vac Circuit Breaker with ML-17 Mechanism


Spare Parts Catalog

Contact Information
Powell Electrical Systems, Inc.
powellind.com
info@powellind.com

Service Division

PO Box 12818
Houston, Texas 77217-2818
Tel: 713.944.6900
Fax: 713.948.4569

Powered by Safety

01.4SP.00003

01.4SP.00003

Signal Words

Qualified Person

As stated in ANSI Z535.4-2007, the signal word is


a word that calls attention to the safety sign and
designates a degree or level of hazard seriousness.
The signal words for product safety signs are
Danger, Warning, Caution and Notice.
These words are defined as:

For the purposes of this manual, a qualified


person, as stated in NFPA 70E, is one who has
skills and knowledge related to the construction
and operation of the electrical equipment and
installations and has received safety training to
recognize and avoid the hazards involved. In
addition to the above qualifications, one must also
be:

DANGER

DANGER indicates an imminently hazardous


situation which, if not avoided, will result in
death or serious injury.

WARNING

WARNING indicates a potentially hazardous


situation which, if not avoided, could result in
death or serious injury.

1. trained and authorized to energize,


deenergize, clear, ground, and tag circuits
and equipment in accordance with
established safety practices.
2. trained in the proper care and use of
personal protective equipment (PPE)
such as rubber gloves, hard hat, safety
glasses or face shields, flash clothing, etc.,
in accordance with established safety
practices.
3. trained in rendering first aid if necessary.

CAUTION

CAUTION, used with the safety alert symbol,


indicates a hazardous situation which, if not
avoided, could result in minor or moderate
injury.

CAUTION
CAUTION, used without the safety alert
symbol, is used to address practices not
related to personal injury.

NOTICE
NOTICE is used to address practices not related
to personal injury.

Powered by Safety

Power/Vac Circuit Breaker with ML-17 Mechanism


Spare Parts Catalog

This page is intentionally left blank.

Powered by Safety

01.4SP.00003

01.4SP.00003

Contents
Ch 1 General Information .................................................................................................1
Ch 2 Safety ........................................................................................................................2
A.
B.
C.
D.
E.
F.

Safe Work Condition . ........................................................................................................................................2


Safety Guidelines ...............................................................................................................................................2
General .............................................................................................................................................................3
Specific ..............................................................................................................................................................3
X-Rays ..............................................................................................................................................................4
Safety Labels .....................................................................................................................................................4

Ch 3 Recommended Renewal Parts ..................................................................................5

A. Ordering Instructions . .......................................................................................................................................5

Closing Coil (FBT) ............................................................................................................................................................................. 9


Closing Coil (STD) ............................................................................................................................................................................. 9
Closing Spring Assembly ................................................................................................................................................................ 9
Potential Trip Coil (3 cycle) ............................................................................................................................................................. 9
Potential Trip Coil (5 cycle) ............................................................................................................................................................. 9
Primary Disconnect Contact Assembly .....................................................................................................................................10
Primary Disconnect Contact Assembly (Continued) .............................................................................................................11
Relay (Non-Nuclear) ......................................................................................................................................................................12
Spring Charging Motor .................................................................................................................................................................12
Undervoltage Trip Device .............................................................................................................................................................12
Auxiliary Switch ..............................................................................................................................................................................13
Brake Assembly ...............................................................................................................................................................................13
Charge - Discharge Flag Operating Rod ...................................................................................................................................13
Close Latch Checking Switch .......................................................................................................................................................13
Closing Roller ..................................................................................................................................................................................13
Closing Spring Gag Interlock .......................................................................................................................................................13
Clutch Assembly for Motor ...........................................................................................................................................................13
Control Switch - Normally Closed ..............................................................................................................................................13
Control Switch - Normally Open .................................................................................................................................................13
Coupling Clamp, Split Ring ..........................................................................................................................................................13
Dash Pot Assembly ........................................................................................................................................................................13
Front Cover Assembly ....................................................................................................................................................................13
Gear Motor Limit Switch ...............................................................................................................................................................14
Ground Rod .....................................................................................................................................................................................14
Negative Interlock Assembly .......................................................................................................................................................14
Opening Stop Bolt Assembly .......................................................................................................................................................14
Operating Rod ................................................................................................................................................................................14
Operation Counter .........................................................................................................................................................................14
Over Travel Stop Adjustment .......................................................................................................................................................14
Pin Retaining Rings, Assortment ................................................................................................................................................14
Pull Rod .............................................................................................................................................................................................14
Rack-Out Arm Assembly ...............................................................................................................................................................14
Redundant Negative Interlock Assembly .................................................................................................................................14

Powered by Safety

Power/Vac Circuit Breaker with ML-17 Mechanism


Spare Parts Catalog

01.4SP.00003

Contents
Secondary Disconnect Assembly - Pin Connectors Not Included .......................................................................................18
Secondary Disconnect Assembly - Pin Connectors, Female (on equipment) ..................................................................18
Secondary Disconnect Assembly - Pin Connectors, Male (on breaker) .............................................................................18
Secondary Disconnect Handle ....................................................................................................................................................18
Spline Adapter Assembly ..............................................................................................................................................................18
Spring Discharge Interlock Assembly ........................................................................................................................................18
Swivel Caster ...................................................................................................................................................................................18
Toggle Pin .........................................................................................................................................................................................18
Trip Roller .........................................................................................................................................................................................18

ii

Powered by Safety

01.4SP.00003

Figures
Figure 1
Figure 2
Figure 3
Figure 4
Figure 5
Figure 6

Front View with Cover .....................................................................................6


Front View without Cover ...............................................................................7
Front View without Cover and Angle Plate Removed ....................................8
Bottom View of Circuit Breaker ....................................................................15
Left Side of Circuit Breaker ...........................................................................16
Rear View of Operating Rod .........................................................................17

Tables
Table A Recommended Renewal Parts (A-Po) (Ratings Included) .....................................9
Table B Recommended Renewal Parts (Pr) (Ratings Included) .......................................10
Table C Recommended Renewal Parts (Pr) (Ratings Included) (cont.) ............................11
Table D Recommended Renewal Parts (R-Z)(Ratings Included) .....................................12
Table E Recommended Renewal Parts (A-F) (No Ratings) ...............................................13
Table F Recommended Renewal Parts (G-R) (No Ratings) ...............................................14
Table G Recommended Renewal Parts (S-Z) (No Ratings) ...............................................18

Powered by Safety

iii

Power/Vac Circuit Breaker with ML-17 Mechanism


Spare Parts Catalog

This page is intentionally left blank.

Powered by Safety

01.4SP.00003

01.4SP.00003

Ch 1 General Information

WARNING

The equipment described in this document may contain high voltages and currents which can
cause serious injury or death.
The equipment is designed for use, installation, and maintenance by knowledgeable users of such
equipment having experience and training in the field of high voltage electricity. This document
and all other documentation shall be fully read, understood, and all warnings and cautions
shall be abided by. If there are any discrepancies or questions, the user shall contact Powell
immediately at 1.800.480.7273.

WARNING

Before any adjustment, servicing, part replacement, or any other act is performed requiring
physical contact with the electrical working components or wiring of this equipment, the power
supply must be disconnected. Failure to follow this warning may result in injury or death.

NOTICE
The information in this instruction bulletin is not intended to explain all details or variations of the
Powell equipment, nor to provide for every possible contingency or hazard to be met in connection
with installation, testing, operation, and maintenance of the equipment. For additional
information and instructions for particular problems, which are not presented sufficiently for the
users purposes, contact Powell at 1.800.480.7273.

NOTICE
Powell reserves the right to discontinue and to change specifications at any time without incurring
any obligation to incorporate new features in products previously sold.

General Information

Powered by Safety

Power/Vac Circuit Breaker with ML-17 Mechanism


Spare Parts Catalog

Ch 2 Safety
A. Safe Work Condition
The information in Section A is quoted from
NFPA 70E 2012 - Article 120, 120.1 Establishing an
Electrically Safe Work Condition.
120.1 Process of Achieving an Electrically Safe
Work Condition
1. Determine all possible sources of electrical
supply to the specific equipment. Check
applicable up-to-date drawings, diagrams,
and identification tags.
2. After properly interrupting the load current,
OPEN the disconnecting device(s) for each
source.
3. Wherever possible, visually verify that all
blades of the disconnecting devices are
fully OPEN or that drawout type circuit
breakers are withdrawn to the fully
disconnected position.
4. Apply lockout/tagout devices in accordance
with a documented and established policy.
5. Use an adequately rated voltage detector
to test each phase conductor or circuit part
to verify they are deenergized. Test each
phase conductor or circuit part both
phase-to-phase, and phase-to-ground.
Before and after each test, determine
that the voltage detector is operating
satisfactorily.

01.4SP.00003

6. Where the possibility of induced voltages


or stored electrical energy exists, ground
the phase conductors or circuit parts
before touching them. Where it could be
reasonably anticipated that the conductors
or circuit parts being deenergized
could contact other exposed energized
conductors or circuit parts, apply ground
connecting devices rated for the available
fault duty.
B. Safety Guidelines
Study this instruction bulletin and all other
associated documentation before installing the
circuit breaker.
Each user has the responsibility to instruct
and supervise all personnel associated with
usage, installation, operation, and maintenance
of this equipment on all safety procedures.
Furthermore, each user has the responsibility of
establishing a safety program for each type of
equipment encountered.
The circuit breakers used in the metal-clad
switchgear described in this instruction bulletin
are operated by a high-energy,
high-speed mechanism that is interlocked
to provide specific operating sequences. It
is mandatory that the following rules be
observed to ensure the safety of personnel
associated with usage, installation, operation,
and maintenance of these circuit breakers.

Informational Note: See ANSI/ISA-61010-1


(82.02.01)/UL 61010-1, Safety Requirements
for Electrical Equipment for Measurement,
Control, and Laboratory Use - Part 1: General
Requirements, for rating and design
requirements for voltage measurement
and test instruments intended for use on
electrical systems 1000 V and below.
2

Powered by Safety

Safety

01.4SP.00003

C. General
1. Only supervised and qualified personnel
trained in the usage, installation, operation,
and maintenance of the circuit breaker shall
be allowed to work on this equipment. It
is mandatory that this instruction bulletin,
any supplements, and service advisories be
studied, understood, and followed.
2. Maintenance programs must be consistent
with both customer experience and
manufacturers recommendations,
including service advisories and instruction
bulletin(s). A well planned and executed
routine maintenance program is essential
for switchgears reliability and safety.
3. Service conditions and circuit breaker
applications shall also be considered in the
development of safety programs. Variables
include ambient temperature; humidity;
actual continuous current; thermal cycling;
number of operations; interrupting duty;
and any adverse local conditions including
excessive dust, ash, corrosive atmosphere,
vermin and insect infestations.
D. Specific

3. EXTREME CARE MUST BE EXERCISED


TO KEEP ALL PERSONNEL, TOOLS, AND
OTHER OBJECTS CLEAR OF MECHANISMS
WHICH ARE TO BE OPERATED,
DISCHARGED, OR RELEASED. These
circuit breakers utilize stored energy
mechanisms. These mechanisms must be
serviced only by skilled and knowledgeable
personnel capable of releasing each spring
load in a controlled manner.
4. DO NOT ATTEMPT TO CLOSE THE CIRCUIT
BREAKER MANUALLY ON AN ENERGIZED
CIRCUIT.
5. DO NOT USE AN OPEN CIRCUIT BREAKER
AS THE SOLE MEANS OF ISOLATING A
HIGH VOLTAGE CIRCUIT. For complete
isolation, the circuit breaker shall be in
the disconnected position or shall be
withdrawn completely.
6. ALL COMPONENTS SHALL BE
DISCONNECTED BY MEANS OF A VISIBLE
BREAK AND SECURELY GROUNDED FOR
SAFETY OF PERSONNEL PERFORMING
MAINTENANCE OPERATIONS ON THE
CIRCUIT BREAKERS, or CONNECTED
EQUIPMENT.

1. DO NOT WORK ON ENERGIZED


SWITCHGEAR. If work must be performed,
the power supply must be disconnected
and deenergized and the switchgear
removed from service prior to performing
any work.
2. DO NOT WORK ON AN ENERGIZED
CIRCUIT BREAKER. If work must be
performed on a circuit breaker, remove the
circuit breaker from service by removing it
from the switchgear. DO NOT LEAVE THE
CIRCUIT BREAKER COMPARTMENT DOOR
OPEN.

Safety

Powered by Safety

Power/Vac Circuit Breaker with ML-17 Mechanism


Spare Parts Catalog

7. Closed-door operation features on the


switchgear allow both circuit breakers
and auxiliary devices to be connected to
or disconnected from the power circuit
with the compartment door closed.
Maintenance functions to either device
will require opening the compartment
door to remove the device. OPENING
THE COMPARTMENT DOOR WITH
THE BUS ENERGIZED REMOVES THE
ARC RESISTANT FEATURES OF THE
DESIGN. PERSONNEL PROTECTIVE
EQUIPMENT (PPE) SUITABLE FOR THE
POTENTIAL EXPOSURE HAZARD MUST
BE WORN IF THE OPERATOR OPENS
ANY HIGH VOLTAGE COMPARTMENT
DOOR WHILE THE EQUIPMENT IS
ENERGIZED. Maintenance operations,
such as fuse replacement on the auxiliary
device, require opening the compartment
door. While it is common practice to
replace fuses in Auxiliary devices with the
equipment is energized, this practice is not
recommended.
8. DO NOT MAKE ANY ADJUSTMENTS,
MODIFICATION, OR DEFORM PARTS. DO
NOT FORCE THE PARTS INTO POSITION.
CONTACT POWELL FOR INSTRUCTIONS.

01.4SP.00003

E. X-Rays
When high voltage is applied across the
contacts of a vacuum interrupter, there is the
possibility of generation of X-rays. The intensity
of the X-radiation is dependent on the peak
voltage and the contact gap. At the normal
operating voltage for this type of equipment,
the radiation levels are negligible. At the
voltages specified for testing, test personnel
shall be in front of the circuit breaker such that
the two layers of steel used in the frame and
front cover construction are between the test
personnel and the vacuum interrupters, and
that the test personnel be no closer than one
meter (3) from the front of the circuit breaker.
THE CIRCUIT BREAKER SHALL BE EITHER
FULLY OPEN, OR FULLY CLOSED WHEN
MAKING HIGH POTENTIAL TESTS. DO NOT
TEST WITH CONTACTS PARTIALLY OPEN.
F. Safety Labels
The equipment described in this document
has DANGER, WARNING, CAUTION, and
instruction labels attached to various locations.
All equipment DANGER, WARNING, CAUTION,
and instruction labels shall be observed
when the switchgear is handled, operated, or
maintained.

NOTICE
Warning and Caution labels are located in
various places in and on the switchgear and
on the circuit breaker. Always observe these
warnings and caution labels. Do NOT remove
or deface any of these warning/caution labels.

Powered by Safety

Safety

01.4SP.00003

Ch 3 Recommended Renewal Parts


A. Ordering Instructions




Always specify complete nameplate data of the breaker.


Specify the quantity, catalog number and reference number (if listed), description and this
bulletin number.
Standard hardware - such as screws, bolts, nuts, washers, etc. - are not listed in this bulletin. These
items should be purchased locally.
Refer to nearest Powell sales office for pricing.
For more instructions or recommended maintenance refer to GEK-90208-P.

Recommended Renewal Parts

Powered by Safety

Power/Vac Circuit Breaker with ML-17 Mechanism


Spare Parts Catalog

Figure 1

01.4SP.00003

Front View with Cover

a.
b.
c.
d.
e.

Front Cover
Secondary Disconnect Handle
Rack-Out Arm Assembly
Charge/Discharge Flag Operating Rod
Operation Counter

Powered by Safety

Recommended Renewal Parts

01.4SP.00003

Figure 2

Front View without Cover

a. Vacuum Interrupter Assembly


b. Operating Rod
c. Swivel Caster

Recommended Renewal Parts

Powered by Safety

Power/Vac Circuit Breaker with ML-17 Mechanism


Spare Parts Catalog

Figure 3

01.4SP.00003

Front View without Cover and Angle Plate Removed

a
b
c

e
f
g

a. Dash Pot Assembly (hidden)


b. Potential Trip Coil
c. Clutch Assembly for Motor
d. Relay
e. Auxiliary Switch
f. Close Latch Checking Switch
g. Closing Coil
h. Control Switch
i. Spring Charging Motor

Powered by Safety

Recommended Renewal Parts

01.4SP.00003

Table A Recommended Renewal Parts (A-Po) (Ratings Included)


Closing Coil (FBT)
Reference

Figure 3, g

Rating

Catalog Number

48 VDC

0282A2009G014

125 VDC

0282A2009G001

250 VDC

0282A2009G002

240 VAC

0282A2009G004

48 VDC

0282A2009G001

125 VDC

0282A2009G002

250 VDC

0282A2009G003

120 VAC

0282A2009G004

240 VAC

0282A2009G005

Use for all 3500A and/or 63kA


Rated Breakers

07100G00450104

Use for Breakers with All Other


Ratings

07100G00450103

48 VDC

0282A2009G001

125 VDC

0282A2009G002

250 VDC

0282A2009G003

48 VDC

0282A2009G007

125 VDC

0282A2009G008

250 VDC

0282A2009G009

Model Designator

Quantity per Breaker

1 or 2
as required

1 or 2
as required

Closing Coil (STD)

Figure 3, g

Closing Spring Assembly


Figure 4, k
Potential Trip Coil (3 cycle)
Figure 3, b
Potential Trip Coil (5 cycle)
Figure 3, b

Recommended Renewal Parts

Powered by Safety

Power/Vac Circuit Breaker with ML-17 Mechanism


Spare Parts Catalog

01.4SP.00003

Table B Recommended Renewal Parts (Pr) (Ratings Included)


Primary Disconnect Contact Assembly
Reference

Rating

Catalog Number

Model Designator

Quantity per Breaker

0282A2701G002

0282A2725G002

0282A2700G003

0209B4272G002

0282A2700G004

4.76KV-31.5KA-1200A
4.76KV-40KA-1200A
8.25KV-40KA-1200A
15.0KV-31.5KA-1200A
15.0KV-40KA-1200A
15.0KV-20KA-1200A
15.0KV-25KA-1200A
4.76KV-50KA-1200A
4.76KV-63KA-1200A
4.76KV-63KA-2000A
8.25KV-50KA-1200A
8.25KV-50KA-2000A
Figure 5, a

8.25KV-63KA-1200A
8.25KV-63KA-2000A
15.0KV-50KA-1200A
15.0KV-50KA-2000A
15.0KV-63KA-1200A
15.0KV-63KA-2000A
4.76KV-31.5KA-2000A
4.76KV-40KA-2000A
4.76KV-50KA-2000A
8.25KV-40KA-2000A
15.0KV-20KA-2000A
15.0KV-25KA-2000A
15.0KV-31.5KA-2000A
15.0KV-40KA-2000A

10

Powered by Safety

Recommended Renewal Parts

01.4SP.00003

Table C Recommended Renewal Parts (Pr) (Ratings Included) (cont.)


Primary Disconnect Contact Assembly (Continued)
Reference

Rating

Catalog Number

Model Designator

Quantity per Breaker

0282A7597G002

4.76KV-31.5KA-3000A
4.76KV-31.5KA-3500A
4.76KV-31.5KA-4000A
4.76KV-40KA-3000A
4.76KV-40KA-3500A
4.76KV-40KA-4000A
4.76KV-50KA-3000A
4.76KV-50KA-3500A
4.76KV-50KA-4000A
4.76KV-63KA-3000A
4.76KV-63KA-3500A
4.76KV-63KA-4000A
8.25KV-40KA-3000A
8.25KV-40KA-3500A
8.25KV-40KA-4000A
8.25KV-50KA-3000A
8.25KV-50KA-3500A
8.25KV-50KA-4000A
8.25KV-63KA-3000A
Figure 5, a

8.25KV-63KA-3500A
8.25KV-63KA-4000A
15.0KV-20KA-3000A
15.0KV-20KA-3500A
15.0KV-20KA-4000A
15.0KV-25KA-3000A
15.0KV-25KA-3500A
15.0KV-25KA-4000A
15.0KV-31.5KA-3000A
15.0KV-31.5KA-3500A
15.0KV-31.5KA-4000A
15.0KV-40KA-3000A
15.0KV-40KA-3500A
15.0KV-40KA-4000A
15.0KV-50KA-3000A
15.0KV-50KA-3500A
15.0KV-50KA-4000A
15.0KV-63KA-3000A
15.0KV-63KA-3500A
15.0KV-63KA-4000A

Recommended Renewal Parts

Powered by Safety

11

Power/Vac Circuit Breaker with ML-17 Mechanism


Spare Parts Catalog

01.4SP.00003

Table D Recommended Renewal Parts (R-Z)(Ratings Included)


Relay (Non-Nuclear)
Reference

Rating
48 VDC

Figure 3, d

Figure 3, d

Catalog Number

Model Designator

Quantity per Breaker

0, 1, 2, 3, 4
(Rev. 0)

4
(Rev. 1)

Model Designator

Quantity per Breaker

0282A2008P001

125 VDC

0282A2008P002

250 VDC

0282A2008G001

120V - 60Hz

0282A2008P003

240V - 60Hz

0282A2008P004

120V - 50Hz

0282A2008P005

240V - 50Hz

0282A2008P006

48 VDC

0282A2008P021

125 VDC

0282A2008P022

250 VDC

0282A2008G021

120 VAC (50/60Hz)

0282A2008P023

240 VAC (50/60Hz)

0282A2008P024

48 VDC

0177C2164G003

125 VDC & 120 VAC

0177C2164G001

250 VDC & 240 VAC

0177C2164G002

Spring Charging Motor


Figure 3, i
Undervoltage Trip Device
Reference
Figure 3, b

Rating

Catalog Number

48 VDC

0282A5218G001

125 VDC

0282A5218G002

250 VDC

0282A5218G003

For replacement interrupter pole assemblies, please record the serial number and rating information
from the breaker data nameplate and contact the factory for pricing.

12

Powered by Safety

Recommended Renewal Parts

01.4SP.00003

Table E Recommended Renewal Parts (A-F) (No Ratings)


Auxiliary Switch
Reference

Catalog Number

Model Designator

Quantity per Breaker

Image

Figure 3, e

0209B3410P003

n/a

0209B3617G001

1 (not required)

0282A2005P002

0282A2000P100

1 or 21

n/a

21

n/a

0282A5061G003

0209B4233G001

0209B3581G0023

Brake Assembly

n/a

Charge - Discharge Flag Operating Rod


Figure 1, d

0282A2009G001

Close Latch Checking Switch


Figure 3, f

n/a

Closing Roller

Figure 4, l

Closing Spring Gag Interlock

Figure 5, b

0282A2181P001

Clutch Assembly for Motor


Figure 4, a

0282A2402G002

Control Switch - Normally Closed


Figure 3, h

0282A2097P002

Control Switch - Normally Open


Figure 3, h

0282A2097P003

Coupling Clamp, Split Ring

Figure 6, a

Dash Pot Assembly


Figure 3, a
Front Cover Assembly
Figure 1, a

Recommended Renewal Parts

Powered by Safety

n/a

13

Power/Vac Circuit Breaker with ML-17 Mechanism


Spare Parts Catalog

01.4SP.00003

Table F Recommended Renewal Parts (G-R) (No Ratings)


Gear Motor Limit Switch
Reference

Catalog Number

Model Designator

Quantity per Breaker

Figure 4, i

0209B3626G001

0282A2147P001

1 (not required)

0282A5045G001

0209B3401G001

0282A206P001

N176P2530B6

N176P2532B6

0282A2015G001

0282A2476P002

0209B3584G001

0209B3584G002

0209B3646G003

0209B646G004

Image

Ground Rod
Figure 4, 0

n/a

Negative Interlock Assembly

Figure 5, d

0177C2131G002

Opening Stop Bolt Assembly


Figure 4, g
Operating Rod
Figure 6, b

n/a

Operation Counter

Figure 1, e

Over Travel Stop Adjustment


1-/8
Figure 4, h
2
Figure 4, h

Pin Retaining Rings, Assortment


n/a

n/a

Pull Rod
Figure 4, j

Rack-Out Arm Assembly


Standard Left
Figure 1, c
Standard Right
Figure 1, c
Seismic Left
Figure 1, c
Seismic Right
Figure 1, c

Redundant Negative Interlock Assembly

Figure 5, c

14

0177C2131G007

Powered by Safety

Recommended Renewal Parts

01.4SP.00003

Figure 4

Bottom View of Circuit Breaker

c
d

f
h

i
j
k
l
n

a. Clutch Assembly for Motor


b. Trip Roller
c. Spring Charging Motor
d. Spring Discharge Interlock
e. Spline Adapter Assembly
f. Toggle Pin
g. Opening Stop Bolt Assembly
h. Over Travel Stop Adjustment Bolt
i. Gear Motor Limit Switch Operator Assembly
j. Pull Rod
k. Closing Spring Assembly
l. Closing Roller
m. Primary Disconnect Assembly
n. Secondary Disconnect Assembly
o. Ground Rod

Recommended Renewal Parts

Powered by Safety

15

Power/Vac Circuit Breaker with ML-17 Mechanism


Spare Parts Catalog

Figure 5

01.4SP.00003

Left Side of Circuit Breaker

c
d

a.
b.
c.
d.

16

Primary Disconnect Assembly


Closing Spring Gag Interlock
Redundant Negative Interlock Assembly
Negative Interlock Assembly

Powered by Safety

Recommended Renewal Parts

01.4SP.00003

Figure 6

Rear View of Operating Rod

a. Coupling Clamp, Split Ring


b. Operating Rod

Recommended Renewal Parts

Powered by Safety

17

Power/Vac Circuit Breaker with ML-17 Mechanism


Spare Parts Catalog

01.4SP.00003

Table G Recommended Renewal Parts (S-Z) (No Ratings)


Secondary Disconnect Assembly - Pin Connectors Not Included
Reference

Catalog Number

Model Designator

Quantity per Breaker

Figure 4, n

0209B3579G001

Image

Secondary Disconnect Assembly - Pin Connectors, Female (on equipment)


Figure 4, n

0282A2081P0022

none

Secondary Disconnect Assembly - Pin Connectors, Male (on breaker)


Figure 4, n

23

0177C2130G005

02824555P001

0282A2081P001

Secondary Disconnect Handle

n/a

0209B3542G001

Spline Adapter Assembly

Figure 4, e

0282A5219G001

Spring Discharge Interlock Assembly

Figure 4, d

Swivel Caster

Figure 2, c

Toggle Pin
Figure 4, f

Refer to Factory

Trip Roller
Figure 4, b

18

0282A2000P002

n/a

1)

Use in the breakers with the following on nameplate:


Transfer Dead Time with Load 3 Cycle - Use With Like Breaker

2)

Pin connectors require removal and crimping tools available from AMP, Inc. Pin removal tool
P/N 453300-1. Crimping tool Model D Catalog #69710, Die Catalog #90306-1.

3)

Standard front cover. Contact factory for special breaker front covers.

Powered by Safety

Recommended Renewal Parts

01.4SP.00003
Power/Vac Circuit Breaker Spare Parts Catalog
Equipped with ML-17 Mechanism
5kV & 15kV, (1200A, 2000A, 3000A, 3500A, & 4000A), up to 63kA
January 2015

Powell Electrical Systems, Inc.


Service Division - Houston
PO Box 12818 Houston, TX 77217

Powered by Safety
2006 Powell Industries, Inc. All rights reserved.

Tel: 713.944.6900 Fax: 713.948.4569


powellind.com
info@powellind.com