You are on page 1of 2

Exicom 200A Rectifier

Description
Exicom 200A rectifier is a wide range 320 to 480V
AC three Phase/4wire, with full power output
over full input range. A micro-controller based
design-enabling menu driven setting and advance
design providing near Sinusoidal input current
with low harmonics distortions and near unity
power Factor. Compact and lightweight suitable
for mounting in racks with capacity to
accommodate up to 5 Rectifier modules in a rack
power system along with Monitoring & control
unit.

Main Features

Energy saving Leading edge efficiency


Advance energy saving functionality
Modular Design for parallel Operation.
Leading edge power density
Wide AC Input Voltage Range
Protection against loss of Neutral
AC Over Voltage Protection
Extended operating temperature Range

Applications

BSC
MSC
Fixed line application, Data communication

Advantages
Innovative Design: active power factor
correction and resonant mode topologies allow
high switching frequency giving rectifier
compact and dense design with high efficiency.
Better Heat Management: Front-to-back air
flow with chassis-integrated heat sinks gives the
module the most suitable environment.
Easy Maintenance & Serviceability: Modular
design, hot plugs lead to minimum time to
replace/add rectifiers.

Exicom 200A Rectifiers are leaders in Power


density and fully complied to BSNL TEC spec
no TEC/GR/FLA/SMP-001/06 June 2010. In
addition to high efficiency, it ensures lower
total energy consumption and leads to
smaller environmental footprints.
With a focus on continuous improvement of
total cost of ownership, Exicom Rectifiers
combined with advance controlling and
monitoring reducing both CAPEX and OPEX.

Exicom 200A Rectifier


Technical specification
AC INPUT
Voltage
Frequency
Power Factor
Input
Protection

DC OUTPUT
Voltage
Output Power
Maximum
Current
Current
Sharing
Static Voltage
Regulation
Dynamic
Voltage
Regulation
Ripple &
Noise
Output
Protection

320-480 V AC (Nominal 400V)


48Hz-52Hz
0.99

Internal Fuse
MOV for Transient
Galvanic Isolation

OTHER SPECIFICATIONS
92% Typical
Efficiency
3 KVAC Input & Output
Isolation
0.5 KVDC Output & Earth
1.5 KVAC Input & Earth
AC input Abnormal
Alarms

56Vdc
11200W
200A Maximum
10 % Typical
0.5% from 10% to 100% load

5% for 10%-90% or 90% to


10% load variation
Regulation time <10 mS

<100mV peak to peak


<2mV rms Psophometric

Overvoltage shutdown
Overload
Inrush Current limiting
Short Circuit

Overload
Rectifier Ok/FAIL
Current limit
Fan Fail

Communication Fail
-15C to + 50C

Operating
Temp.
Cooling
Acoustic
Noise
Visual
Indication

Humidity

Forced Cooling
< 60dBA

Green LED - SMR OK


Red LED - SMR Fail
Amber (Blinking) - DC U/V
Amber (continuous) - Temp.
Shutdown
Operating: 5% to 95% RH noncondensing

APPLICABLE STANDARDS
IEC61312
Electrical Safety
MECHANICAL
450mm x 311mm x 450mm
Dimension
(W x H x D)

EMC

Environment

IEC61024
VDE - V0100 - 534
EN 61000 6 4
EN 61000 6 3
EN 61000 6 2
EN 61000 6 1
QM333 category B2 of QA
Wing of BSNL