You are on page 1of 2

Code

Description

E01

Jam not reaching the exit sensor: The paper which has passed through the fuser unit
does not reach the exit sensor.

E02

Stop jam at the exit sensor: The trailing edge of the paper does not pass the exit sensor
after its leading edge has reached this sensor.

E03

Power-ON jam: The paper is remaining on the paper transport path when power is
turned ON.

E09

Jam at the registration area due to registration timeout error

E12

Bypass misfeeding (Paper not reaching the registration sensor): The paper fed from the
bypass tray does not reach the registration sensor.

E13

Drawer misfeeding (Paper not reaching the registration sensor): The paper fed from the
drawer does not reach the registration sensor.

E14

PFU drawer misfeeding (Paper not reaching the PFU feed sensor): The paper fed from
the PFU drawer does not reach the PFU feed sensor.

E21

PFU drawer transport jam (Paper not reaching the registration sensor): The paper does
not reach the registration sensor after it has passed the PFU feed sensor.

E40

Transfer cover open jam: The transfer cover has opened during printing.

E41

Front cover open jam: The front cover has opened during printing.

E44

PFU cover open jam: The PFU cover has opened during printing.

E71

Jam not reaching the original registration sensor: The original fed from the original
feeding tray does not reach the original registration sensor.

E72

Jam not reaching the read sensor: The original does not reach the read sensor after it
has passed the registration sensor.

E73

Stop jam at the exit sensor: The trailing edge of the original does not pass the exit sensor
after its leading edge has reached this sensor.

E86

ADF jam access cover open: The ADF jam access cover has opened during ADF
operation.

E87

ADF open jam: ADF has opened during ADF operation.

C01

Main motor abnormality: The main motor is not rotating normally.

C21

Scanning system
CIS unit initialization error

C26

Scanning system
Peak detection error: Lighting of the exposure lamp (white reference) is not detected
when power is turned ON.

C41

Thermistor or heater abnormality at power-ON: Abnormality of service call the thermistor


is detected when power is turned ON or the temperature of the fuser roller does not rise
in a specified period of time after power is turned ON.

C43

Thermistor abnormality during warming up or in ready status after abnormality judgment

C44

Heater abnormality after abnormality judgment: The temperature of the fuser roller has
exceeded the range of control (in this case, the main switch turns OFF automatically) or
does not even reach the range.

C45

Thermistor abnormality during printing: Abnormality of the thermistor is detected during


printing

C55

ADF I/F error: Communication error has occurred between the ADF and the scanner

C94

Firmware update error: An error message appears when firmware for e-STUDIO166/206
is updated on e- STUDIO163/203 by mistake, and the power is turned OFF and then
back ON after the update.

C97

High-voltage transformer abnormality: Leakage of the main charger is detected.

CA1

Polygonal motor abnormality: The polygonal motor is not rotating normally

CA2

H-Sync detection error: H-Sync detection PC board cannot detect laser beams.

F14

Invalid backup counter: The value of the total counter is inconsistent with that of the
backup counter