CMCI

SUPER PLIOCURE
CURES, SEALS, HARDENS
AND DUSTPROOFS
SUPER PLIOCURE is a high solids butadiene
styrene polymer curing, sealing, hardening and
dustproofing compound. It retains maximum water in concrete, thus ensuring full development of
strength and may be used over both interior and
exterior concrete.*
FEATURES
l High solids content for increased curing efficiency.
l Provides a transparent curing film for new
concrete.
l Seals all concrete surfaces - old or new providing glossy appearance and easier
cleaning
l Hardens new concrete by promoting a
proper cure for improved abrasion resistance.
l Dustproofs concrete by impregnating surface pores with tough film.
l Protects fresh concrete from rain damage
after drying.
l Compatible with many paints, adhesives
and resilient floor coverings.
l Higher coverage rates than with standard
solids formulas.
l New formula utilizes aromatic solvent for
safer storage and shipping.
APPLICATIONS
l Industrial floor slabs
l Walls and columns
l Concrete toppings
l Parking garages
l Warehouses
l Dry shake hardened floors
l Passenger and freight terminals.
SPECIFICATIONS AND COMPLIANCES
l ASTM C 309, type 1 & 1D, Class B
l Resilient tile Institute Specifications
l AASHTO Specification M-148, Type 1 & 1D
l U.S.D.A.
l Federal Specification TTC - 800 A
l Approved by Ohio EPA for contract with
public drinking water supplies.
l May affect appearance - see precautions
ENGINEERING DATA
l Drying time - Less than one hour
l Salt spray, 500 hours exposure - passes
l Adhesion to concrete - passes
l Flash Point, - 43oC
l Adhesion of Asphalt Tile - Passes
l Alkali Resistance, 48 hour exposure -

passes
l Solvent Resistance - Minimal
PACKAGING
Available in 210 liter drums and 20 liter pails.
DIRECTIONS FOR USE
Curing - For the best cure of freshly placed concrete, apply SUPER PLIOCURE as soon as possible after finishing operations and/or immediately
after the disappearance of the sheen of surface
moisture. Application should be by spray, lambs
wool applicator or short nap roller. DO NOT cover
more area than can be worked in 10 minutes as
the Pliocure membrane will start to dry.
Sealing - When sealing old concrete, the surface
must be clean and dry. Remove contaminants
and stains such as waxes, grease and oil with
strong soaps or caustics rather than acids. Badly
worn or porous areas may need a second application to attain a uniform seal and surface gloss.
Apply SUPER PLIOCURE with spray, lambswool
applicator or short nap roller.
Anti-spall Treatment - Use two coats of the standard SUPER PLIOCURE formulation.
COVERAGE RATES M2/LITER*
Purpose of Application
Curing and sealing
New concrete
Sealing and Dustproofing
Old concrete
Anti-spalling Protection

Curing and sealing


New concrete
Sealing and Dustproofing
Old concrete
Anti-spalling Protection

First coat
9.8 - 11.0
11.0 - 12.3
Use Standard
Pliocure
Optional second
11.0 - 12.3
12.3 - 14.7
Use Standard
Pliocure

* Coverage rates assume hard trowelled floors


Coverage will vary from the above rates depending on surface texture. AVOID EXCESSIVE
BUILD-UP
PRECAUTIONS AND LIMITATIONS
l Do not apply over bleed water or free standing water.
l Use with adequate ventilation and keep away
from open flame - contains aromatic solvent and is classified as combustible.

Quality Construction Chemicals


CONSTRUCTION MATERIAL CHEMICAL INDUSTRIES P.O. Box 7137, Dammam 31462, Saudi Arabia
Tel: 00966-3-8471450; Fax: 00966-3-8471575; Email: tech@cmci-sa.com Web: www.cmci-sa.com

l Spray application of Super Pliocure formula must be done with a high pressure
or airless sprayer.
l Do not apply over concrete to receive concrete toppings, epoxy or urethane based
coatings or adhesives. KUREZ DR is recommended for these applications.
l Super Pliocure may darken, yellow or
slightly change the appearance of exterior
pavements
l Although compatible with many carpet, tile
and floor covering adhesives, a test section is recommended for questionable adhesives. Complete membrane removal or
the use of KUREZ DR or EUCOSIL is recommended in areas to receive movable
carpet squares
l Do not use as a bond breaker for tilt-up construction.
l Do not use in areas which may be subject
to hot oil, grease, or fat spillages such as
kitchens.

CLEAN-UP
Tools and equipment may be cleaned with Euco
Solvent, xylene, xylol or toluene. Run cleaning
solvent through spray equipment to remove material and prevent clogging of nozzle in future
use.

Quality Construction Chemicals


CONSTRUCTION MATERIAL CHEMICAL INDUSTRIES P.O. Box 7137, Dammam 31462, Saudi Arabia
Tel: 00966-3-8471450; Fax: 00966-3-8471575; Email: tech@cmci-sa.com Web: www.cmci-sa.com