You are on page 1of 4

Type

Severity

Hardware

Major

Power

Major

Power

Major

Power

Major

Power

Major

Environment

Critical

Environment

Critical

Environment

Critical

Hardware

Major

Hardware

Major

Hardware

Major

Hardware

Major

Power

Major

Hardware

Major

Hardware

Major

Hardware

Major

Hardware

Major

Hardware

Major

Hardware

Major

Hardware

Major

Hardware

Major

Running

Major

Running

Major

Communication

Major

Hardware

Major

Hardware

Minor

Hardware

Major

Signaling

Major

Hardware

Major

Running

Major

Trunk

Major

Trunk

Major

Trunk

Minor

Trunk

Major

Trunk

Minor

Trunk

Minor

Trunk

Minor

Trunk

Major

Trunk

Major

Trunk

Major

Alarm Name

ALM-25602
ALM-25621
ALM-25622
ALM-25625
ALM-25628
ALM-25670
ALM-25671
ALM-25672
ALM-25673
ALM-26107
ALM-26110
ALM-26111
ALM-26112
ALM-26204
ALM-26205
ALM-26221
ALM-26222
ALM-26234
ALM-26235
ALM-26236
ALM-26270
ALM-26276
ALM-26277
ALM-26504
ALM-26527
ALM-26529
ALM-28003
ALM-28006
ALM-28019
ALM-28020
ALM-25800
ALM-25801
ALM-25802
ALM-25803
ALM-25804
ALM-25806
ALM-25807
ALM-25860
ALM-25861
ALM-25880

Sensor Failure
Power Supply DC Output Out of Range
Mains Input Out of Range
Battery Current Out of Range
AC Surge Protector Fault
Water Alarm
Smoke Alarm
Burglar Alarm
Fan Stalled
Board Input Voltage Out of Range
BBU Fan Stalled
BBU Fan Not at Full Speed
BBU DC Output Out of Range
Board Not In Position
BBU Board Maintenance Link Failure
Transmission Optical Module Not In Position
Transmission Optical Interface Error
BBU CPRI Interface Error
RF Unit Maintenance Link Failure
RRU Cascading Levels and Configuration Mismatch
Inter-System Communication Failure
Inter-System Site-Level Configuration Conflict
Inter-System Control Rights Conflict
RF Unit CPRI Interface Error
RF Unit Input Power Out of Range
RF Unit VSWR Threshold Crossed
AC Input Power Failure
Radio Signaling Link Disconnected
Board Configuration Error
Site Configuration Error
E1/T1 Loss of Signal
E1/T1 Alarm Indication Signal
E1/T1 Remote Alarm Indication Signal
E1/T1 Loss of Frame Alignment
E1/T1 Loss of Multiframe Alignment
E1/T1 Excessive Bit Error Rate
E1/T1 Loopback
PPP/MLPPP Link Fault
MLPPP Group Fault
Ethernet Link Fault

Procedure
Open case to check the sensor and its cable connection on site
Open case to check power system
Open case to check power system
Open case to check baterry
Open case to check power system
Open case to check for water damage
Open case to check for fire or the sensor is failing
Check for a FOP working on site
Open case to check the fan
Open case to check the board
Open case to check the fan
Open case to check the fan
Open case to check power system
Open case to check the board
Open case to check the board
Open case to check optical module
Open case to check optical module
Open case to check fiber and optical module
Open case to check fiber and optical module
Check configuration
Check main control board
Check clock configuration parameters
Check settings of the node
Open case to check RF unit and the fiber
Open case to check RF unit
Open case to check RF unit and VSWR
Open case to check power supply of the BTS
Check radio link
Check RF unit
Check configuration parameters
Check the E1/T1 configuration and transmission on site
Check the E1/T1 configuration and transmission on site
Check the E1/T1 configuration and transmission on site
Check the E1/T1 configuration and transmission on site
Check the E1/T1 configuration and transmission on site
Check the E1/T1 configuration and transmission on site
Check the E1/T1 configuration and transmission on site
look over MLPPP, TX
look over MLPPP, TX
look over Ethernet, TX

Notes
a sensor is faulty
the DC output of the power system is out of range
external power failure alarm, mains input is out of range
the battery current is out of range during charging and discharging
the AC surge protector of the base station is faulty
the equipment room or the cabinet is waterlogged
high density smoke is detected in the equipment room
Intruder alarm
fan is faulty
board detects that the input voltage is extremely high or low
the rotation speed of the BBU fan is extremely low
the actual rotation speed of the BBU fan is lower than 80% of the preset full speed
the 12 V DC output of the power module in the BBU is out of range (overvoltage or undervoltage)
board-in-position signal is not detected
the maintenance link between the main control board and the other boards in the subrack malfunctions
the optical module on the transmission port of the BBU is not in position
the optical transmission malfunctions on the transmission port of the BBU
data transmission on the CPRI link (at the link layer) malfunctions between the BBU and the lower-level RF units
the maintenance link between the BBU and the RF unit malfunctions
the actual RRU cascading levels mismatch the configuration
when the main control board in the current mode cannot communicate with the main control board in the other mode
The clock reference type of a mode is incorrect
the loading control rights are not configured or inconsistent between different modes in the base station
data transmission on the CPRI link (at the link layer) is abnormal between the RF unit and the peer device (upper-level/lower-level RF unit or BBU)
the baseband input power from the BBU to the RF unit is beyond the normal power range of the RF unit
the VSWR at the antenna port of the TX channel of an RF unit is higher than the preset threshold
the AC power supply for the BTS is unavailable
the radio signaling link (RSL) between the BSC and the TRX fails
the TRX board is configured incorrectly
The site-level parameter is not correctly set
Loss of Signal (LOS) is detected on the E1/T1 RX port, the system disables the associated E1/T1 link
all 1s signal (Alarm Indication Signal, abbreviated as AIS) is detected on the E1/T1 RX port
Remote Alarm Indication (RAI) is detected on the E1/T1 RX port
when Loss of Frame Alignment (LFA) is detected on the E1/T1 RX port
when Loss of Multiframe Alignment (LMFA) is detected on the E1/T1 RX port
when the bit error rate (BER) on the E1/T1 link exceeds the preset threshold (1E-5 by default, user-definable)
when the user sets the local or remote loopback on the E1/T1 link through the MML command, or when the E1/T1 physical loopback is performed
when the PPP/MLPPP link status is changed from UP to DOWN
when the MLPPP group status is changed from UP to DOWN
Ethernet link is broken