Inthistrainingmodule,wewilldiscussundergroundstoragetankoperatortraining.ByAugust8,2012,
eachownerandoperatorofanyregulatedUSTsystemmustcompleteanOfficeofStateFireMarshall
(OSFM)approvedtrainingprogramontheproperoperationofundergroundstoragetanksystems.Roles
andTrainingaredifferentiatedbetweenthreeoperatorclasses.AClassoperatorhastheprimary
responsibilitytooperateandmaintainthetanksystemandfocusesonthestatutoryandregulatory
requirements.AClassBoperatorisresponsibleforfieldimplementationoftheapplicableUSTsystem
requirementsandimplementsdaytodayaspectsofoperating,maintaining,andrecordkeepingforUST
systemsatoneormorefacilities.AClassCoperatorhasadailyonsitepresenceandisgenerallythefirst
lineofresponsetohandleemergenciesandalarmspertainingtoaspillorreleasefromthetanksystem.
AnticipatedtimetocompletethisModuleis1520minutes.
SectionNumberandName
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
1.9
1.10
1.11
1.12
1.13
1.14
1.15
1.16
1.17
1.18
Class
OperatorTraining
USTOperatorTrainingOverview
RegulatoryOverview
ClassesofOperators
OperatorAvailabilityandPresence
ClassAOperatorSpecificResponsibilities
ClassAOperatorTrainingRequirements
ClassBOperatorSpecificResponsibilities
ClassBOperatorTrainingRequirements
MonthlyInspectionsandMaintenance
OperationsandMaintenancePlan
QuarterlyUSTSystemInspections
ClassCOperatorResponsibilities
ClassCOperatorTraining
TrainingandCertificationProcess
NewOperatorsandRetraining
DocumentationandRecordkeeping
OperatorTrainingSummary
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
USTSystems:Part1TanksandPiping
Thismoduleispart1of2modulesthatwillhelpyoulearnabouttheequipmentrelatedtoan
undergroundstoragetanksystem(orUST)system.AUSTsystemincludesbothundergroundand
abovegroundcomponentsandequipmentusedtostoreanddispenseproduct,suchasgasolineordiesel.
Someofthesecomponentsandequipmentinclude:storagetanksandlines,spillbucketsandsumps,
dispensers(orMPDs),ventandvaporlines,releasedetectionequipmentsuchasautomatictankgauges
(orATGs),andotherancillaryequipment.
Business Confidential
API/AnteaGroupOperatorTrainingCourseSyllabus
StateofIllinois,OfficeofStateFireMarshall
Page2
TherearemanyfederalandstateregulationsthatgovernhowaUSTsystemshouldoperate,how
equipmentcanbeused,andotherrequirementstoensurethesystemisoperatingproperly,suchastank
andlinetestingandinspections.AnticipatedtimetocompletethisModuleis2025minutes.
SectionNumberandName
2.1
2.2
2.3
2.4
2.5
2.6
2.7
2.8
2.9
2.10
2.11
2.12
2.13
2.14
2.15
2.16
2.17
2.18
2.19
2.20
2.21
2.22
2.23
2.24
2.25
2.26
2.27
2.28
2.29
2.30
2.31
2.32
2.33
Class
USTSystems:Part1TanksandPiping
USTSystemOverview
TanksandPipingOverview
TheUndergroundStorageTanks
DefinitionofaUST
RegulatedSubstances
SinglewalledUSTs
SinglewalledUSTsconstruction
SinglewalledSteelUSTs
SinglewalledFiberglassUSTs
DoublewalledUSTs
InterstitialSpace
DoublewalledUSTsconstruction
DoublewalledSteelUSTs
DoublewalledFiberglassUSTs
MarineTanks
Piping
DefinitionofUndergroundPiping
SuctionandPressurizedPiping
AtmosphericPiping
SinglewalledPiping
DoublewalledPiping
InterstitialSpace
PipingConstruction
OSFMPermitsRequireCertifiedContractors
SchedulingofPermittedWork
USTSystemRepairs
USTSystemEmergencyRepairs
MotorFuelFacilityDispensingPermits
MotorFuelFacilityDispensingFacilities
MotorFuelFacilityDispensingControlandEmergencyShutOffs
MotorFuelFacilityDispensing OtherRequirements
Summary
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
USTSystems:Part2AncillaryEquipment
Thismoduleispart2of2modulesthatwillhelpyoulearnabouttheequipmentrelatedtoan
undergroundstoragetanksystem(orUST)system.AUSTsystemincludesbothundergroundand
abovegroundcomponentsandequipmentusedtostoreanddispenseproduct,suchasgasolineordiesel.
Someofthesecomponentsandequipmentinclude:storagetanksandlines,spillbucketsandsumps,
dispensers(orMPDs),ventandvaporlines,releasedetectionequipmentsuchasautomatictankgauges
(orATGs),andotherancillaryequipment.
Business Confidential
API/AnteaGroupOperatorTrainingCourseSyllabus
StateofIllinois,OfficeofStateFireMarshall
Page3
TherearemanyfederalandstateregulationsthatgovernhowaUSTsystemshouldoperate,how
equipmentcanbeused,andotherrequirementstoensurethesystemisoperatingproperly,suchastank
andlinetestingandinspections.AnticipatedtimetocompletethisModuleis1520minutes.
SectionNumberandName
3.1
3.2
3.3
3.4
3.5
3.6
3.7
3.8
3.9
3.10
3.11
3.12
3.13
3.14
3.15
Class
USTSystems:Part2AncillaryEquipment
USTSystemOverview
AncillaryEquipmentOverview
DefinitionofAncillaryEquipment
SubmersibleTurbinePump
SubmersibleTurbinePumpSump
STPSumpSensors
UncontainedSubmersibleTurbinePumps
FillPortandDropTube
VaporRecovery
TypesofVaporRecoverySystems
Dispensers
UnderDispenserContainment
OSFMPermitsRequireCertifiedContractors
SummaryofAncillaryEquipment
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
SpillandOverfillControlPrevention
Spillsandoverfillsofregulatedsubstances(suchasgasolineordiesel)oftenoccurwhentheproduceis
beingdeliveredintoastoragetank.Whenaspilloccurs,itcanseepintothedirt(orsoil)aroundastorage
tank,possiblycontaminatinglocalwatersupplies.Contaminationofsoilorwatercanaffectthehealthof
peopleandnegativelyaffectourenvironment.
Inthismodule,youwilllearnaboutthedifferentmethodsofspillandoverfillpreventionforastorage
tanksystemandtheregulatoryrequirementsforyourstate.Spillandoverfillpreventionmethodsare
intendedtopreventreleasesorspillsfromoccurringduringthedeliveryofproduct,suchasgasolineor
diesel,toyourstoragetanksystem.AnticipatedtimetocompletethisModuleis1520minutes.
Business Confidential
API/AnteaGroupOperatorTrainingCourseSyllabus
StateofIllinois,OfficeofStateFireMarshall
Page4
SectionNumberandName
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
4.9
4.10
4.11
4.12
4.13
4.14
4.15
4.16
4.17
4.18
Class
SpillandOverfillControlandPrevention
ModuleOverview
GeneralRegulations
GeneralRegulations
SpillPrevention
SpillBucketsforProductContainment
SpillBucketDrains
SpillBucketManualPumping
SpillBucketLids
SpillBucketOperationandMaintenance
OverfillProtection
OverfillAlarms
OverfillAlarmOperationandMaintenance
BallFloatValves
AutomaticShutoffDevices
AutomaticShutoffDeviceOperationandMaintenance
ContainmentSumps
Summary
Business Confidential
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
API/AnteaGroupOperatorTrainingCourseSyllabus
StateofIllinois,OfficeofStateFireMarshall
Page5
ReleaseDetectionOverview
Allfederallyregulatedstoragetanksystems,particularlythetanksandpiping,arerequiredtohave
releasedetection.Releasedetectionreferstoaprocessormethod,ofteninvolvingspecialequipment
and/orOperatortasks,toidentifyanyleaksthatoccurwithinthestoragetanksystem.Shouldarelease
(orleak)occurfromastoragetanksystem,itisimportanttodiscoverthemquicklytoavoid
contaminationtotheenvironment,suchasthegroundorwatersupply.
TherearemanymethodsofreleasedetectionuptosevenasidentifiedbyFederalregulations.
Dependinguponyourspecificstate,someofthesemethodsmaynotbeacceptable.Inthismodule,we
willdiscussreleasedetectionregulationsforyourstateandbrieflyreviewacceptablemethods.This
moduleisintendedforClassAandBOperatorsandwillsatisfytheReleaseDetectiontraining
requirementsforClassAOperators.However,ClassBOperatorswillalsoberequiredtocomplete
separatemodulesforeachmethodofleakdetectionindividuallysincetheyarerequiredtohavea
detailedunderstandingofhowthesemethodswork.AnticipatedtimetocompletethisModuleis12
15minutes.
SectionNumberandName
5.1
5.2
5.3
5.4
5.5
5.6
5.7
5.8
5.9
5.10
5.11
5.12
Class
ReleaseDetectionOverview
ModuleOverview
GeneralRequirements
PerformanceIssuesandNotifications
Recordkeeping
RecordkeepingContinued
HazardousSubstanceStorageTanks
PetroleumStorageTankSystems Tanks
PetroleumStorageTankSystems PressurizedPiping
PetroleumUSTSystemsSuction Piping
MethodsofReleaseDetection
Summary
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
GroundwaterandVaporMonitoringMethods
Inthismodule,wewilllearnabouttwomethodsofreleasedetection,GroundwaterMonitoringand
VaporMonitoring.Thesetwomethodsofreleasedetectionrequiretheinstallationofwellsor
monitoringpointsaroundtheundergroundstoragetanksandpiping.Measurementscanbecollected
eithermanuallyorelectronicallyforeachmethod.AnticipatedtimetocompletethisModuleis1215
minutes.
Business Confidential
API/AnteaGroupOperatorTrainingCourseSyllabus
StateofIllinois,OfficeofStateFireMarshall
Page6
SectionNumberandName
Class
6.1
6.2
6.3
6.4
6.5
6.6
6.7
6.8
6.9
6.10
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
GroundwaterandVaporMonitoringMethods
ModuleOverview
GroundwaterMonitoringReleaseDetection
RegulatoryRequirements
MonitoringEquipmentandInstallation
MonitoringWellPlacement
VaporMonitoringReleaseDetection
RegulatoryRequirements
RecordkeepingandReporting
Summary
ManualTankGaugingandInventoryControl
Inthismodule,wewilllearnaboutManualTankGaugingandInventoryControl.Thesearemethods
ofreleasedetectionthatinvolvetakingmanualmeasurementsofthetankscontentsonaweeklyordaily
basistoseeiftherehavebeenchangesinvolumethatwouldindicateapossibleleak.Manualtank
gaugingonlyappliestostoragetankswithcapacitiesofupto2000gallons.Ownersoftankswitha
capacityofgreaterthan600gallonsmustalsoconductannualtanktightnesstestingandmustuse
anothermethodofleakdetectionwithintenyearsofinstallation.InventoryControlrequiresdailytank
volumemeasurementsandisapplicabletolargertanks.Productvolumeinformation,alongwithproduct
deliveriesandproductsales,isusedtoreconciletheproductinventorytodetermineifthereisareleasein
thestoragetanksystem.InventorycontrolisaTEMPORARYmethodofleakdetectionandcanonlybe
usedforaperiodof10yearsafterthedatecathodicprotectionwasfirstinstalledonthetank.
AnticipatedtimetocompletethisModuleis1520minutes.
SectionNumberandName
7.1
7.2
7.3
7.4
7.5
7.6
7.7
7.8
7.9
7.10
7.11
7.12
7.13
7.14
7.15
7.16
Class
ManualTankGaugingandInventoryControl
TheGaugeStick
GaugingPaste
LocatingtheDropTube
TheTankChart
ManualTankGauging
Regulations
Weekly/MonthlyResultsVersusTestStandards
ManualTankGaugingStandards
ManualInventoryControl
InventoryControlRequirements
DailyandMonthlyInventoryForms
MonthlyReconciliationResults
OperationandMaintenance
PrecisionTankTightnessTesting
Summary
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
StatisticalInventoryReconciliation
Inthismodule,wewilllearnaboutStatisticalInventoryReconciliation(SIR).Thismethodofrelease
detectionrequiresextremelyaccurateproductmeasurementswhichareusuallytakenmanually.These
resultsarethenanalyzedbysophisticatedcomputersoftware,takingintoaccountseveralfactorsand
-
Business Confidential
API/AnteaGroupOperatorTrainingCourseSyllabus
StateofIllinois,OfficeofStateFireMarshall
Page7
datapatternstodetermineinatanksystemisleaking.AnticipatedtimetocompletethisModuleis15
20minutes.
SectionNumberandName
8.1
8.2
8.3
8.4
8.5
8.6
8.7
8.8
8.9
8.10
8.11
Class
StatisticalInventoryReconciliation
StatisticalInventoryReconciliation Limits
UnderstandingSIR
StatisticalInventoryReconciliation Methods
SIRRequirements
SIRVendors
TheMonthlySIRReport
SIRResultsPassandInconclusive
SIRResultsFail
Recordkeeping
Summary
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AutomaticTankGauging
Inthismodule,wewilllearnaboutAutomaticTankGaugingorATGSystems.ATGsuseproductand
waterlevelprobespermanentlyinstalledinthetank.Theseprobesarelinkedelectronicallytoanearby
controldevice,typicallytheelectronicmonitoringpanel,toprovideinformationonproductleveland
temperature.Thegaugingsystemcanautomaticallycalculatethechangesinproductvolumethatcan
indicatealeakingtank.Thismethoddoesnotworkonpiping.AnticipatedtimetocompletethisModule
is1215minutes.
SectionNumberandName
9.1
9.2
9.3
9.4
9.5
9.6
9.7
9.8
9.9
9.10
9.11
Class
AutomaticTankGauging
Overview
FeaturesandRequirementsforATGs
InTankLeakTests
StaticLeakTests
StaticandContinuousLeakTests
InTankLeakTestResults
Recordkeeping
OtherConsiderations
ATGMaintenance
Summary
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
10 SecondaryContainmentandInterstitialMonitoring
Inthismodule,wewilllearnaboutamethodofreleasedetectionthatusesSecondaryContainmentwith
Interstitialmonitoring.ThisinvolvesplacingabarrierbetweentheUSTandtheenvironment.Thebarrier
providessecondarycontainmentandcanbeavault,liner,ortheouterwallofadoublewalledstructure.
Interstitialmonitoringmethodsrangefromasimpledipsticktoautomatedvapororliquidsensors
permanentlyinstalledinthesystem.Theregulationsdescribegeneralperformancerequirementsfor
interstitialmonitoringwithdoublewalledUSTs,USTsfittedwithinternalliners,andUSTsusing
interceptionbarriers.AnticipatedtimetocompletethisModuleis1215minutes.
Business Confidential
API/AnteaGroupOperatorTrainingCourseSyllabus
StateofIllinois,OfficeofStateFireMarshall
Page8
SectionNumberandName
10.1
10.2
10.3
10.4
10.5
10.6
10.7
10.8
10.9
10.10
10.11
Class
SecondaryContainmentandInterstitialMonitoring
Overview
UnderstandingSecondaryContainment
UnderstandingInterstitialMonitors
RegulatoryRequirements
DoubleWalledTanks
InterstitialSensors
Pressure/VacuumSensorsandHydrostaticSensors
Recordkeeping
ReportingRequirements
Summary
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
A andB
11 ReleaseDetectionforPiping
Allfederallyregulatedstoragetanksystems,whichincludepiping,arerequiredtohavereleasedetection.
Releasedetectionreferstoaprocessormethod,ofteninvolvingspecialequipmentand/orOperator
tasks,toidentifyanyleaksthatoccurwithinthestoragetanksystem.Shouldarelease(orleak)occur
fromstoragetanksystempiping,itisimportanttodiscoverthemquicklytoavoidcontaminationtothe
environment,suchasthegroundorwatersupply.
Dependinguponyourspecificstate,someofthesemethodsmaynotbeacceptable.Inthismodule,we
willdiscussreleasedetectionregulationsforyourstateandbrieflyreviewacceptablemethods.Forthose
takingtheClassBcourse,amoredetailedreviewofsomeofthemethodsofreleasedetectionforpiping
willalsobereviewedinthismodule.ThismoduleisintendedforClassAandBOperatorsandwillsatisfy
theReleaseDetectiontrainingrequirementsforbothClasses.AnticipatedtimetocompletethisModule
is1215minutes.
SectionNumberandName
11.1
11.2
11.3
11.4
11.5
11.6
11.7
11.8
11.9
11.10
11.11
11.12
11.13
11.14
Class
ReleaseDetectionforPiping
ModuleOverview
MethodsofReleaseDetectionforPiping
EuropeanSuctionPiping
AmericanSuctionPiping
PressurizedPiping
PressurizedPipingContinued
AutomaticLineLeakDetectors(LLDs)
LineTightnessTesting
SecondaryContainmentwithInterstitialMonitoring
VaporandGroundwaterMonitoring
NewPipingSystems
Recordkeeping
Summary
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
12 CorrosionProtection
Inthistrainingmodule,wewillintroduceyoutocorrosionprotectionsystems.Cathodicprotection,a
methodofcorrosionprotection,isareleasepreventionmethodspecifictometalcomponents,suchas
steelstoragetanks,pipingorothermetalequipmentassociatedwiththestoragetanksystem.
Business Confidential
API/AnteaGroupOperatorTrainingCourseSyllabus
StateofIllinois,OfficeofStateFireMarshall
Page9
Youwilllearnwhatacorrosionprotectionsystemis,whycorrosionprotectionsystemsarerequired,the
differenttypesofcathodicprotectionsystems,howthedifferentcathodicprotectionsystemswork,and
anyagencyrecordkeepingorreportingrequirements.ThismoduleisintendedforClassAandB
OperatorsandwillsatisfytheCorrosionProtectiontrainingrequirementsforbothClasses.Anticipated
timetocompletethisModuleis1520minutes.
SectionNumberandName
12.1
12.2
12.3
12.4
12.5
12.6
12.7
12.8
12.9
12.10
12.11
12.12
12.13
12.14
12.15
12.16
12.17
Class
CorrosionProtection
CorrosionProtectionOverview
TypesofCorrosionProtection
AssessingTankIntegrityBeforeUpgrade
Upgrade
InteriorTankLiningInspections
CathodicProtection
Cathodicprotectionsystemtypes
ImpressedCurrent
ImpressedCurrentTestingandRecordkeeping
GalvanicCathodicProtectionSystem
GalvanicHeavyDutyCoating
GalvanicSacrificialAnodes
SacrificialAnodesotherconsiderations
GalvanicDielectricorNylonBushings
GalvanicTestingandRecordkeeping
CorrosionProtectionSummary
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
13 EmergencyResponseandAttendantResponsibilities
Inthismodule,wewillreviewemergencyresponseproceduresthatwillenablestoragetankownersor
operatorstorespondtoemergenciesoralarmscausedbyspills,releasesorothereventsassociatedwith
thestoragetanksystem.WealsoaddressresponsibilitiesofAttendantsataSelfServiceMotorFuel
DispensingFacility.
Thismodulewillincludeareviewofbothmajorandminorspillsandreleasesthatcanoccur,andwewill
discussthenecessaryequipmentandsuppliesneededtorespondtoanemergency.Wewillalsodiscuss
writtenplansorprocedurestoassistinpreparingandrespondingtoanemergency,andwewillreview
OperatorresponsibilitiesforA,BandCoperators.AnticipatedtimetocompletethisModuleis1520
minutes.
Business Confidential
API/AnteaGroupOperatorTrainingCourseSyllabus
StateofIllinois,OfficeofStateFireMarshall
Page10
SectionNumberandName
13.1
13.2
13.3
13.4
13.5
13.6
13.7
13.8
13.9
13.10
13.11
13.12
13.13
13.14
13.15
13.16
Class
ClassCOperatorTraining
EmergencyResponseandAttendantDuties
ExamplesofanEmergency
USTSystemAlarms
Majorspillsorreleases
EmergencyResponsePlanandProcedures
TheEmergencyShutoffSwitch
MinorSpillsorLeaks
Handlingminorspillsorleaks
HandlingminorspillsorleaksContinued
FireExtinguishersandEmergencySupplies
FireExtinguisherUse
AdditionalOwnerandClassAandBResponsibilities
AttendantDutiesataMotorFuelDispensingFacility
OtherFacilityOperatingRequirements
EmergencyResponseSummary
ClassCOnly
A,BandC
A,BandC
A,BandC
A,BandC
A,BandC
A,BandC
A,BandC
A,BandC
A,BandC
A,BandC
A,BandC
A,BandC
A,BandC
A,BandC
A,BandC
14 ProductandEquipmentCompatibility
Inthistrainingmodule,wewilldiscussproductandequipmentcompatibility.Productreferstoa
regulatedsubstance,suchasgasolineordiesel;andequipmentreferstostorageortransfermaterials
intendedtocomeintocontactwithregulatedsubstances,suchasthestoragetanksystem.
Compatibilityisameasureofhowwelltheproductandequipmentcanbeunaffectedbyprolonged
contactwitheachother.
Inotherwords,howwelldoestheequipmentinteractwiththeproductbeingstored?Willtheequipment
slowlycorrodeordegradeovertimeifitremainsincontactwiththeproduct?Willthecharacteristicsof
theproduct,suchasoctanelevels,remainwithinstandardsiftheyremainincontactwithequipmentover
time?Thesequestionsalladdressthecompatibilityoftheproductandequipment.Thismoduleis
intendedforClassAandBOperatorsandwillsatisfytheProductCompatibilitytrainingrequirementsfor
bothClasses.AnticipatedtimetocompletethisModuleis1215minutes.
SectionNumberandName
14.1
14.2
14.3
14.4
14.5
14.6
14.7
14.8
14.9
14.10
14.11
14.12
Class
ProductandEquipmentCompatibility
ModuleOverview
Biofuels
UnderstandingEthanol
EthanolUSTOperationConsiderations
UnderstandingBiodiesel
BiodieselStorageTankOperationConsiderations
EPAUSTCompatibilityforBlendsOverE10andB20(1of2)
EPAUSTCompatibilityforBlendsOverE10andB20(2of2)
OptionsifListingisUnattainable
FuelConversions
ProductCompatibilitySummary
Business Confidential
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
API/AnteaGroupOperatorTrainingCourseSyllabus
StateofIllinois,OfficeofStateFireMarshall
Page11
15 FinancialResponsibility
ThismoduleisprimarilyintendedforstoragetanksystemOwnersorClassAOperators.Thepurpose
forthismoduleistoeducateOwnersoftheirrequirementstodemonstratefinancialresponsibilitytothe
regulatoryagency.FinancialresponsibilityreferstoanOwnersabilitytocompensateimpactedthird
partiesandtoconductcorrectiveactionintheeventofareleaseofproduct,suchasdieselorgasoline,
totheenvironmentfromtheirstoragetanksystem.
ItisimportantthatallOwnersorClassAOperatorsunderstandthefinancialresponsibilityrequirements
foranystate.Itissuggestedthatinadditiontothistrainingcourse,youreviewtheappropriate
regulationsregardingfinancialresponsibilityrequirements,whetheryouareaneworlongtimeOwner.
AnticipatedtimetocompletethisModuleis1520minutes.
SectionNumberandName
15.1
15.2
15.3
15.4
15.5
15.6
15.7
15.8
15.9
15.10
15.11
15.12
15.13
15.14
15.15
Class
FinancialResponsibility
GeneralRequirements
CoverageAmounts
CoverageAmountsILAdminRules
StateFunding
StateFundingApplicableCodeandDeductibles
StateFundingEligibility
FinancialResponsibilityMechanisms
FinancialResponsibilityCancellationorBankruptcy
ReportingandRecordkeeping
SelfInsurance
GuaranteesandInsuranceCoverage
SuretyBonds
LettersofCredit
Summary
Aonly
Aonly
Aonly
Aonly
Aonly
Aonly
Aonly
Aonly
Aonly
Aonly
Aonly
Aonly
Aonly
Aonly
Aonly
16 NotificationandRegistrationRequirements
ThismoduleisprimarilyintendedforstoragetanksystemOwnersorClassAOperators.Thepurpose
forthismoduleistoprovideanoverviewofthenotificationandregistrationrequirementsnecessaryto
ownandoperateastoragetanksystem.
ItisimportantthatallOwnersorClassAOperatorsunderstandthenotificationandregistration
requirementsforanystate.Itissuggestedthatinadditiontothistrainingcourse,youreviewthe
appropriateregulationsregardingnotificationandregistrationrequirements,whetheryouareanewor
longtimeOwner.AnticipatedtimetocompletethisModuleis1215minutes.
Business Confidential
API/AnteaGroupOperatorTrainingCourseSyllabus
StateofIllinois,OfficeofStateFireMarshall
Page12
SectionNumberandName
16.1
16.2
16.3
16.4
16.5
16.6
16.7
16.8
16.9
16.10
16.11
16.12
16.13
16.14
Class
NotificationandRegistrationRequirements
MotorFuelDispensingFacilityPermits
USTActivityPermits
SchedulingofUSTActivities
TankInstallationCertificationandTestingResult
NotificationFormforUSTs
NotificationandRegistrationRequirement
NotificationandRegistrationHeating OilUSTs
Pre'74andHeatingOilTanks
CertificationbyOwnersandInstallers
TransferofOwnershipandNewFacilityRegistration
AmendedNotificationFormSubmittal
DeliveryProhibitionRedTagging
Summary
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
17 ReleaseReporting
ReleaseReportingreferstoastoragetankownersresponsibilitiestonotifytheregulatoryagencyofa
suspectedorconfirmedrelease(orleak)ofregulatedsubstance,suchasgasolineordiesel.Whileall
operatorshavearoleinreleasereporting,thismoduleisdirectedatClassAOperatorsandwillsatisfy
theReleaseReportingtrainingrequirementsforthem.AnticipatedtimetocompletethisModuleis12
15minutes.
SectionNumberandName
17.1
17.2
17.3
17.4
17.5
17.6
17.7
17.8
17.9
17.10
17.11
17.12
17.13
17.14
17.15
Class
ReleaseReporting
ReleaseReportingOverview
ReportingandCleanUpofSpillsandOverfills
SpillsandOverfillsHazardousSubstanceStorageTanks
ReleaseReportingNotification
ReleaseReportingNotificationRequirements
ConditionsthatWarrantReleaseReporting
ProceduresforRestartingaSystem
SuspectedReleaseInvestigation
ConfirmedReleases
SiteAssessmentRequirements
SiteAssessmentReportForm
InitialAbatement
FreeProductRemoval
ReleaseReportingSummary
Business Confidential
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
API/AnteaGroupOperatorTrainingCourseSyllabus
StateofIllinois,OfficeofStateFireMarshall
Page13
18 ClosureRequirements
ThismoduleisprimarilyintendedforStorageTanksystemOwnersandOperatorsandClassAOperators.
ThepurposeforthismoduleistoeducateOwnersandOperatorsoftheirrequirementswhenceasing
operations(Closing)astoragetanksystem,eithertemporarilyorpermanently.Thismodulewillreview
thestepsnecessarytocomplywithfederalandstateregulationsduringclosureactivitiesandany
operationalorreportingresponsibilitiesnecessary.
ItisimportantthatallClassAOperatorsunderstandtheclosurerequirements.Itissuggestedthatin
additiontothistrainingcourse,ClassAOperatorsreviewtheappropriateregulationsregardingstorage
tanksystemclosurerequirements,whethertheyareneworlongtimeOwner/Operators.Anticipated
timetocompletethisModuleis1215minutes.
SectionNumberandName
18.1
18.2
18.3
18.4
18.5
18.6
18.7
18.8
18.9
18.10
18.11
18.12
18.13
Class
ClosureRequirements
PermitRequirementsandChicagoDelegation
NotificationRequirements
TemporaryUSTClosure
PuttingTemporarilyClosedUSTsBackintoService
ChangeinService
TankSystemRemoval
TankAbandonmentinPlace
SiteAssessmentRequirementsatTankClosure
SiteAssessmentReport
Pre74andHeatingOilTanks
ClosureRecords
Summary
Business Confidential
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB
AandB