Conplast P510M

constructive solutions

Water reducing admixture


Uses

Dosage

To improve the effectiveness of the water content of a


concrete mix.
A higher dosages to provide a cost effective means of
reducing concrete permeability and thereby reducing
water penetration.

The optimum dosage of Conplast P510M to meet specific


requirements should always be determined by trials using
the materials and conditions that will be experienced in use.
The normal dosage range is 0.2 - 0.6 litre per 100 kg of
cementitious material, including PFA, GGBFS and microsilica.

Advantages

Use at other dosages

Particularly effective in improving compressive strength


of mixes containing PFA and GGBFS

Dosages outside the normal dosage range quoted above


can be used to meet particular mix requirements. Contact
Fosroc for advice in these cases.

Water reducing significantly improves compressive


strengths at all ages and increases durability.

Properties

Allows workability to be increased without adding extra


water.
Allows specified strength grades to be met at reduced
cement content or increased workability.
Chloride free, safe for use in pre-stressed concrete.

Appearance:
Specific gravity:
Chloride content:
Air entrainment:

Alkali content:

Standard compliance
Conplast P510M complies with BS5075 Part 1 and with
ASTM C494 as Type A and Type D, depending on dosage
used.
Conplast P510M complies with the requirements of the
United Kingdom Water Fittings Byelaws Scheme and is
listed in the Directory of Materials as suitable for use in
contact with potable water.
Description
Conplast P510M is a chloride free water reducing admixture
based on a blend of selected lignosulphonate and
hydrolysed carbohydrate materials. It is supplied as a
brown solution which instantly disperses in water.

Brown liquid
o
Typically 1.230 at 20 C
Nil to BS5075
Typically less than 2% additional
air is entrained at normal
dosages
Typically less than 4.0 g. Na2O
equivalent per litre of admixture.
A fact sheet on this subject is
available

Instructions for use


Compatibility
Conplast P510M is compatible with other Fosroc admixtures
in the same concrete mix. All admixtures should be added
to the concrete separately and must not be mixed together
prior to addition. The performance of concrete containing
more than one admixture should be assessed by trial mixes.
Conplast P510M is suitable for use with all types of Ordinary
Portland Cements and cement replacement materials such
as PFA, GGBFS and micro-silica.
Effects on stiffening and set.

Conplast P510M disperses the fine particles in the concrete


mix, enabling the water content of the concrete to perform
more effectively and improving the consistency of the
concrete. This produces higher levels of workability for the
same water content, allowing benefits such as water
reduction and increased strengths to be taken.
Technical support
Fosroc provides a technical advisory service for on-site
assistance and advice on mix design, admixture selection,
evaluation trials and dispensing equipment.

Most water reducing admixtures produce some delay in the


stiffening of concrete, although the degree may vary.
Retardation is affected by factors other than the admixtures,
depending on the mix details and conditions involved. Trials
to assess the effects in a particular mix are strongly
recommended if this aspect is of particular importance.
Major factors which may lead to an increase in retardation
include the following.
a) Cement replacement materials will usually give greater
levels of retardation than concrete mixes and with
Ordinary Portland Cement at the same admixture
dosage.

Page 1

Conplast P510M
b) Low temperatures will give higher levels of retardation
for the same admixture dosage. This is particularly
noticeable if cement replacement materials are used.

Freezing point: Approximately - 4oC.

c) Increased cement contents, which lead to higher total


levels of admixture in a cubic metre of concrete, may
lead to increased retardation being obtained.

Health and safety

d) Changes in cement source or chemistry may lead to


variations in the retardation obtained. The amount of tricalcium aluminate in the cement has been identified as
being one of the main contributory factors in this
respect, with a lower level leading to greater retardation.
Increased retardation will be obtained at higher dosage. As
a guideline, dosages of 0.31 litres per 100 kg and above are
likely to be in the retarding category.

Precautions

Conplast P510M does not fall into the hazard classifications


of current regulations (see notes 1 and 2 below). However,
it should not be swallowed or allowed to come into contact
with skin and eyes. Suitable protective gloves and goggles
should be worn.
Splashes on the skin should be removed with water. In
case of contact with eyes rinse immediately with plenty of
water and seek medical advice. If swallowed seek medical
attention immediately - do not induce vomiting.
For further information consult the Material Safety Data
Sheet available for this product.

Dispensing
The correct quantity of Conplast P510M should be
measured by means of a recommended dispenser. The
admixture should then be added to the concrete with the
mixing water to obtain the best results. Contact Fosroc for
advice regarding suitable equipment and its installation.

Fire

Effects of overdosing

Spillages of Conplast P510M should be absorbed onto


sand, earth or vermiculite and transferred to suitable
containers. Remnants should be hosed down with large
quantities of water.

An overdose of double the amount of Conplast P510M will


results in significant retardation. Provided that adequate
curing is maintained, the ultimate strength of the concrete
will not be impaired by increased retardation and will
generally be increased. The effects of overdosing will be
further increased if sulphate resisting cement or cement
replacement materials are used.
Over-dosage may also cause increased air entrainment,
which will tend to reduce strength. The degree of this effect
will depend on the particular mix design and overdose level.

Conplast P510M is water based and non-flammable.


Cleaning and disposal

The disposal of excess or waste material should be carried


out in accordance with local legislation under the guidance
of the local waste regulatory authority.
Note 1: CPL Regulations 1984 Supply-Schedule 1
Note 2: HSE publication Guidance Note EH40
See separate data sheets.

Estimating - Packaging
Conplast P510M is available in drum or bulk supply. For
larger users, storage tanks can be supplied.
Storage
Conplast P510M has a minimum shelf life of 12 months
o
provided the temperature is kept within the range of 2 C to
o
50 C. Should the temperature of the product fall outside
this range then the Fosroc Sales Support Department
should be contacted for advice.

Important note:
Fosroc products are guaranteed against defective materials and manufacture and are sold subject to its standard Conditions
for the Supply of Goods and Services, copies of which may be obtained on request. Whilst Fosroc endeavours to ensure that
any advice, recommendation, specification of information it may give is accurate and correct, it cannot, because it has no direct
or continuous control over where or how its products are applied, accept any liability either directly or indirectly arising from the
use of its products, whether or not in accordance with any advice, specification, recommendation of information given by it.

Fosam Company Limited


Head Office
Post Box 11081
Jeddah - 21453
Saudi Arabia

www.fosroc.com

Telephone: +966 2 637 5345

Fax: +966 2 637 5891

email: fosam@fosroc.com

Regional Offices
Jeddah Sales Office
Jeddah Showroom
Riyadh
Dammam
Khamis Mushayt

Tel: (02) 608 0999


Tel: (02) 665 0187
Tel: (01) 482 9303
Tel: (03) 814 1282
Tel: (07) 250 0469

Fax: (02) 635 3330


Fax: (02) 667 4844
Fax: (01) 482 7562
Fax: (03) 814 1581
Fax: (07) 250 0469

Yanbu Tel: (04) 322 4280


Makkah Tel: (02) 542 0869
Medinah Tel: (04) 845 1767
Jubail Tel: (03) 362 3904

Fax: (04) 391 2980


Fax: (02) 542 0869
Fax: (04) 846 3195
Fax: (03) 362 3875

Registered Office: Industrial Area, Phase 4, Road No. 414, Street No. 407

Page 2

FO SA/CONPLAST P510M/05/A

You might also like