Professional Documents
Culture Documents
G2R- @ - @ @ @@ -@@
1
2 3 4 5
6 7
1. Relay Function
None: Single-side stable
K : Double-winding latching
4. Contact Type
None: Single
Z : Bifurcated contact
2. Number of poles
1: 1-pole
2: 2-pole
5. Enclosure rating
None: Flux protection
(T-type is an enclosed
relay)
4 : Fully sealed
3. Contact Form
None: NO/NC
A : NO
6. Terminal Shape
None: PCB terminals
T : Quick-connect
(upper bracket mounting
#187)
7. Classification
None: Standard
E : High-capacity
H : High-sensitivity
U : For ultrasonically
cleanable
Z : Full-wave rectifier
G
2
R
Model Configuration
Number of poles
Terminal
Shape
Classification
Enclosure
rating
Flux protection
Standard
Fully sealed
Bifurcated
PCB terminals contact
Flux protection
Fully sealed
Contact
form
AC
DC
AC
DC
DC
AC
1-pole
SPST-NO (1a)
2-pole
SPDT (1c)
DPST-NO (2a)
DPDT (2c)
G2R-1A
G2R-1
G2R-2A
G2R-2
G2R-1A4
G2R-14
G2R-2A4
G2R-24
G2R-1AZ
G2R-1Z
G2R-1AZ4
G2R-1Z4
G2R-1A-E
G2R-1-E
High-capacity
Flux protection
High-sensitivity
Flux protection
DC
G2R-1A-H
G2R-1-H
G2R-2A-H
G2R-2-H
Double-winding
latching
Flux protection
DC
G2RK-1A
G2RK-1
G2RK-2A
G2RK-2
G2R-1A-T
G2R-1-T
Quick-connect Standard
Unsealed
DC
AC
DC
Minimum
packing
unit
50
pcs/tray
100
pcs/tray
Note 1. Full-wave rectifier and supersonic cleaner compatible models are also available. Refer to page 3.
2. Sockets for PCB terminal models are not provided.
Use the plug-in terminal Relay instead of socket if necessary.
G2R
Ordering Information
PCB Terminal Models
Number of poles
Classification
Enclosure rating
Contact form
1-pole
Model
2-pole
Model
G2R-1A
200/(220) VAC
5, 6, 12, 24, 48 VDC
G2R-2A
100 VDC
Flux protection
NO/NC
G2R-1
General-purpose
NO
G2R-1A4
Fully sealed
NO/NC
G2R-14
High-sensitivity
Flux protection
Double-winding
latching
200/(220) VAC
5, 6, 12, 24, 48 VDC
100 VDC
200/(220) VAC
200/(220) VAC
G2R-2
100 VDC
100 VDC
200/(220) VAC
5, 6, 12, 24, 48 VDC
G2R-2A4
200/(220) VAC
5, 6, 12, 24, 48 VDC
100 VDC
100 VDC
200/(220) VAC
5, 6, 12, 24, 48 VDC
G2R-24
100 VDC
G
2
R
200/(220) VAC
5, 6, 12, 24, 48 VDC
100 VDC
NO
G2R-1A-H
G2R-2A-H
NO/NC
G2R-1-H
G2R-2-H
NO
G2RK-1A
5, 6, 12, 24 VDC
G2RK-2A
5, 12, 24 VDC
NO/NC
G2RK-1
5, 6, 12, 24 VDC
G2RK-2
5, 6, 12, 24 VDC
NO
G2R-1AZ
NO/NC
G2R-1Z
NO
G2R-1AZ4
NO/NC
G2R-1Z4
Flux protection
Bifurcated
contact
Fully sealed
100 VDC
5, 12, 24, 48 VDC
100 VDC
5, 12, 24, 48 VDC
100 VDC
12, 24, 100/(110) VAC
NO
High-capacity
G2R-1A-E
200/(220) VAC
5, 6, 12, 24, 48 VDC
100 VDC
Flux protection
G2R-1-E
200/(220) VAC
5, 6, 12, 24, 48 VDC
100 VDC
Note: When ordering, add the rated coil voltage to the model number.
Example: G2R-1A 12 VAC
Rated coil voltage
G2R
Enclosure rating
Contact form
1-pole
Model
NO
General-purpose
G2R-1A-T
200/(220) VAC
5, 6, 12, 24, 48 VDC
100 VDC
Unsealed
G2R-1-T
200/(220) VAC
5, 6, 12, 24, 48 VDC
100 VDC
Full-wave Rectifier
Number of poles
Classification
Enclosure rating
Contact form
NO
1-pole
Model
G2R-1A-Z
Flux protection
NO/NC
G2R-1-Z
General-purpose
NO
G2R-1A4-Z
Fully sealed
High-capacity
NO/NC
G2R-14-Z
NO
G2R-1A-EZ
NO/NC
G2R-1-EZ
Flux protection
2-pole
Model
G2R-2A-Z
G2R-2-Z
G2R-2A4-Z
G2R-24-Z
G
2
R
100 VDC
5, 12, 24 VDC
100 VDC
Enclosure rating
Contact form
1-pole
Model
2-pole
Model
G2R-1A4-U
Fully sealed
NO/NC
G2R-14-U
200/(220) VAC
G2R-2A4-U
5, 12, 24 VDC
G2R-24-U
Note: When ordering, add the rated coil voltage to the model number.
Example: G2R-1A-T 12 VAC
Rated coil voltage
G2R
Ratings
Coil
Item
Classification
Rated voltage
General-purpose
Quick-connect
Fully sealed
High-capacity
12 VAC
93
75
24 VAC
46.5
37.5
100/(110) VAC
11
200/(220) VAC
5 VDC
General-purpose
High-capacity
Bifurcated contact
Quick-connect
Fully sealed
High-sensitivity
5.5
Must operate
voltage (V)
Must release
voltage (V)
Max. voltage
(V)
Power
consumption
(VA, W)
% of rated voltage
65
260
9/(10.6)
4,600
4.5/(5.3)
20,200
106
80% max.
30% min.
140%
(at 23C)
Approx. 0.9
(60 Hz)
70% max.
15% min.
170%
(at 23C)
Approx. 0.53
70% max.
15% min.
170%
(at 23C)
Approx. 0.36
47
6 VDC
88.2
12 VDC
43.6
275
24 VDC
21.8
1,100
68
48 VDC
11.5
4,170
100 VDC
5.3
18,860
5 VDC
71.4
6 VDC
60
100
12 VDC
30
400
24 VDC
15
1,600
48 VDC
G
2
R
60 Hz
Coil resistance
()
70
7.5
6,400
Note 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of+15%/-20% (AC rated current) or 10% (DC coil resistance).
2. AC coil resistances shown above are only reference values.
3. The operating characteristics are measured at a coil temperature of 23C.
4. The Max. voltage is the maximum voltage that can be applied to the relay coil.
Set Coil
Rated current
(mA)
Must set
voltage (V)
Reset coil
Coil resistance
()
Rated current
(mA)
Coil resistance
()
42
5 VDC
167
30
119
6 VDC
138
43.5
100
60
12 VDC
70.6
170
50
240
24 VDC
34.6
694
25
960
% of rated voltage
70% max.
70% max.
Note 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%.
2. The operating characteristics are measured at a coil temperature of 23C.
3. The Max. voltage is the maximum voltage that can be applied to the relay coil.
140%
(at 23C)
Power consumption
Set Coil
(mW)
Reset coil
(mW)
Approx.
850
Approx.
600
G2R
Contacts
Classification
Number of poles
Load
Item
General-purpose
Quick-connect Terminal (1single-pole type)
1-pole
High-capacity
Bifurcated contact
1-pole
2-pole
2-pole
High-sensitivity
1-pole
2-pole
Inductive
Inductive
Inductive
Inductive
Inductive
Inductive
load
load
load
load
load
load
Resistive
Resistive
Resistive
Resistive
Resistive
Resistive
(cos = 0.4;
(cos = 0.4;
(cos = 0.4;
(cos = 0.4;
(cos = 0.4;
(cos = 0.4;
load
load
load
load
load
load
L/R = 7 ms)
L/R = 7 ms)
L/R = 7 ms)
L/R = 7 ms)
L/R = 7 ms)
L/R = 7 ms)
Contact type
Single
Single
Bifurcated
Contact material
Single
Rated load
Rated carry current
7.5 A at
250 VAC
5 A at 30
VDC
5 A at 250
VAC
5 A at 30
VDC
10 A
2 A at 250
VAC
3 A at 30
VDC
16 A at
250 VAC
16 A at 30
VDC
5A
8 A at 250
VAC
8 A at 30
VDC
5 A at 250
VAC
5 A at 30
VDC
16 A
2 A at 250
VAC
3 A at 30
VDC
5A
5 A at 250
VAC
5 A at 30
VDC
2 A at 250
VAC
3 A at 30
VDC
3 A at 250
VAC
3 A at 30
VDC
5A
1 A at 250
VAC
1.5 A at
30 VDC
3A
380 VAC, 125 VDC
10 A
5A
16 A
5A
5A
3A
100 mA at 5 VDC
10 mA at 5 VDC
100 mA at 5 VDC
1 mA at 5 VDC
100 mA at 5 VDC
10 mA at 5 VDC
Number of poles
Load
Item
Bifurcated contact
1-pole
Resistive load
(cos = 1)
Contact type
2-pole
Inductive load
(cos = 0.4; L/R = 7 ms)
Resistive load
(cos = 1)
Single
1-pole
Inductive load
(cos = 0.4; L/R = 7 ms)
Resistive load
(cos = 1)
Single
Contact material
Inductive load
(cos = 0.4; L/R = 7 ms)
Bifurcated
G
2
R
Rated load
Rated carry current
6 A at 250 VAC
4 A at 30 VDC
4 A at 250 VAC
4 A at 30 VDC
5 A at 250 VAC
5 A at 30 VDC
2 A at 250 VAC
3 A at 30 VDC
8A
4A
5A
8A
4A
5A
100 mA at 5 VDC
10 mA at 5 VDC
1 mA at 5 VDC
Load
1-pole
Resistive load
(cos = 1)
Contact type
2-pole
Inductive load
(cos = 0.4; L/R = 7 ms)
Single
Inductive load
(cos = 0.4; L/R = 7 ms)
Single
Contact material
Rated load
Resistive load
(cos = 1)
3 A at 250 VAC
3 A at 30 VDC
5A
3A
5A
3A
100 mA at 5 VDC
10 mA at 5 VDC
G2R
Characteristics
Standard Relays
Item
Number of poles
Contact resistance *1
Time *2
Set
Min. set pulse width
Time *2
Reset
Min. reset pulse
width
Max. operating Mechanical
frequency
Electrical
Insulation resistance *3
Between coil and
contacts
Between contacts
of different polarity
Dielectric
Between contacts
strength
of the same
polarity
Between set and
reset coils
Malfunction
Destruction
Shock
resistance
1-pole
2-pole
30 m max.
50 m max.
20 ms max.
30 ms
20 ms max.
30 ms
18,000 operations/hr
1,800 operations/hr
1,000 M min. (at 500 VDC)
5,000 VAC, 50/60 Hz for 1 min
3,000 VAC,
50/60 Hz for 1 min
Destruction
Vibration
resistance
Malfunction
Mechanical
Durability
Electrical
Ambient operating temperature
Ambient operating humidity
Weight
Engineering Data
AC resistive load
10
5
DC resistive load
AC
inductive load
(cos = 0.4)
G2R-1-E, G2R-1A-E
DC inductive load
(L/R = 7 ms)
G2R-1Z, G2R-1AZ
50
AC resistive load
16
10
5
DC resistive load
AC
inductive load
(cos = 0.4)
DC inductive load
(L/R = 7 ms)
10
20 30 50 100
10
20 30 50 100
10
AC resistive load
5
DC resistive load
1
AC
inductive load
(cos = 0.4)
50
10
AC resistive load
DC resistive load
DC inductive load
(L/R = 7 ms)
0.5
G2R-2-H, G2R-2A-H
Switching current (A)
50
500
AC
inductive load
(cos = 0.4)
0.5
DC inductive load
(L/R = 7 ms)
0.1
0.1
0
10
20 30 50 100
500
AC resistive load
5
AC
inductive load
(cos = 0.4)
DC inductive load
(L/R = 7 ms)
0.1
500
10
0.5
0.1
0.1
50
DC resistive load
0.5
0.5
50
G
2
R
Item
Number of poles
1-pole
2-pole
Contact resistance *1
30 m max.
50 m max.
Operate time *2
15 ms max.
Release time *2
AC: 10 ms max.; DC: 5 ms max.
Max.
Mechanical
18,000 operations/hr
operating
Electrical
1,800 operations/hr
frequency
Insulation resistance *3
1,000 M min.
Between coil and
5,000 VAC, 50/60 Hz for 1 min
contacts
Between contacts
3,000 VAC, 50/60 Hz
Dielectric
for 1 min
of different polarity
strength
Between contacts
of the same
1,000 VAC, 50/60 Hz for 1 min
polarity
10 to 55 to 10 Hz, 0.75 mm single
Destruction
amplitude (1.5 mm double amplitude)
Vibration
resistance
10 to 55 to 10 Hz, 0.75 mm single
Malfunction
amplitude (1.5 mm double amplitude)
Destruction
1,000 m/s2
Shock
200 m/s2 when energized;
resistance Malfunction
100m/s2 when no energized
AC coil: 10,000,000 operations min.;
Mechanical
DC coil: 20,000,000 operations min.
(at 18,000 operations/hr)
Durability
100,000 operations min.
Electrical
(at 1,800 operations/hr under rated load)
Ambient operating temperature
-40C to 70C (with no icing)
Ambient operating humidity
5% to 85%
Weight
Approx. 17 g (Approx. 20 g *4)
10
20 30 50 100
500
10
20 30 50 100
500
G2R
G2RK-1A, G2RK-1
50
10
AC resistive load
5
50
10
5
AC resistive load
3
AC
inductive load
(cos = 0.4)
DC resistive load
1
0.5
AC
inductive load
(cos = 0.4)
DC resistive load
1
0.5
DC inductive load
(L/R = 7 ms)
DC inductive load
(L/R = 7 ms)
0.1
0.1
5
10
20 30 50 100
500
10
20 30 50 100
G2R-24, G2R-2A4
50
AC resistive load
10
5
G2R-1Z4, G2R-1AZ4
50
10
AC resistive load
DC resistive load
1
AC
inductive load
(cos = 0.4)
1
DC inductive load
(L/R = 7 ms)
0.5
0.5
0.1
5
10
20 30 50 100
300 500
10
20 30 50 100
30
10
5
500
300
250 VAC/30 VDC
resistive load
100
50
30
7.5 8
10
12
14
300
30
10
5
500
300
100
50
30
10
12
14
16
18
1,000
500
300
100
50
30
10
250 VAC inductive load
(cos = 0.4)
1,000
500
50
300 500
G2R-2-H, G2R-2A-H
1,000
100
20 30 50 100
10
10
250 VAC inductive load (cos = 0.4)
30 VDC inductive load (L/R = 7ms)
G2R-1Z, G2R-1AZ
1,000
10
30 VDC inductive load (L/R = 7ms)
G
2
R
AC
inductive load
(cos = 0.4)
DC inductive load
(L/R = 7 ms)
500
50
300 500
G2R-1-E, G2R-1A-E
1,000
DC resistive load
0.1
0
Durability
Flux Protection/Plug-in Relays
G2R-1, G2R-1A, G2R-1-T, G2R-1A-T
100
AC resistive load
5
0.5
DC inductive load
(L/R = 7 ms)
300
10
0.1
0
50
AC
inductive load
(cos = 0.4)
DC resistive load
500
1.5
G2R
1,000
500
300
100
50
30
1,000
500
300
100
50
30
10
10
2.5
3 3.5
1.5
2.5
G
2
R
1,000
500
300
250 VAC/30 VDC
resistive load
250 VAC inductive load
(cos = 0.4)
50
30
G2R-1Z4, G2R-1AZ4
1,000
10
500
300
30 VDC inductive load (L/R = 7ms)
100
50
30
500
300
30 VDC inductive load (L/R = 7ms)
100
10
30
10
250 VAC inductive load
(cos = 0.4)
1.5
2.5 3
200
DC coil
170
150
140
110
100
AC coil
50
40
50
60
70
80
250
30
20
12
50
1,000
10
30 VDC inductive load (L/R = 7ms)
0
25
G2R-24, G2R-2A4
Durability (x104 operations)
100
90 100
100
80
max.
X
60
min.
40
max.
X
20
0
60
min.
40
20
20
40
60
G2R-2
Sample: G2R-1
Number of Relays: 5 pcs
80
G2RK-1A, G2RK-1
100
Sample: G2R-2
Number of Relays: 5 pcs
80
max.
X
60
min.
40
max.
X
min.
20
0
60
40
20
20
40
60
80
SPST-NO (1a)
SPST-NC (1c)
1,000
800
600
400
200
200
400
Z
Test Conditions:
Shock is applied in
X, Y, and Z
directions three times
each with and without
Z'
energizing the Relays
to check the number
of contact
malfunctions.
Requirement:
200 m/s2 when
energized; 100m/s2
when de-energized
X'
600
Shock direction
X'
X
800
400
200
270
200
400
Z
Test Conditions:
Shock is applied in
X, Y, and Z
directions three times
each with and without
Z'
energizing the
Relays to check the
number of contact
malfunctions.
Requirement:
200 m/s2 when
energized; 100m/s2
when de-energized
X'
600
800
Y'
Z
Z'
Unit: m/s2
Y'
Shock direction
X'
X
80
MAX
MIN
60
High
temperature
40
Y
1,000
Shock Malfunction
G2R-1 Number of Relays: 5 pcs
1,000
Y'
Z
Z'
Unit: m/s2
Y'
20
50 100
500 1,000
5,000 10,000
Elapsed time (H)
G2R
Dimensions
Relays with PCB Terminals
(SPDT (1c) Relays)
G2R-1(-Z)
G2R-1Z
G2R-1-H
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
29 max.
(28.8)*
3.5
3.5
(2.7)
25.5 max.
(25.3)*
7.5
Five, 1.3-dia.
holes
(0.3)
(2.1)
4
0.5
0.5**
20
0.3
0.16
** Average value
** 0.3 (-H Type)
13 max.
(12.7)*
29 max.
(28.8)*
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
25.5 max.
(25.3)*
7.5
Four, 1.3-dia.
holes
(0.3)
(2.1)
0.3
0.5**
0.16
20
G
2
R
** Average value
** 0.3 (-H Type)
13 max.
(12.6)*
29 max.
(28.6)*
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
2.5
2.5
(2.7)
25.5 max.
(24.9)*
7.5
(0.3)
0.5
0.3
1
(2.1)
0.3
0.16
* Average value
(2.1)
20
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
13 max.
(12.6)*
29 max.
(28.6)*
2.5
2.5
(2.7)
25.5 max.
(24.9)*
7.5
(0.3)
0.3
1
(2.1)
0.3
0.16
20
(2.1)
* Average value
G2R
13.5 max.
(12.9)*
29 max.
(28.6)*
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
3.5
25.5 max.
(24.8)*
(2.7)
7.5
Five, 1.3-dia.
holes
4
0.5
0.5
(2.1)
20
0.3
0.16
* Average value
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
13.5 max.
(12.9)*
29 max.
(28.6)*
3.5
25.5 max.
(24.8)*
(2.7)
7.5
Four, 1.3-dia.
holes
4
0.5
0.3
0.16
(2.1)
20
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
13 max.
(12.8)*
3.5
3.5
(2.7)
25.5 max.
(25.2)*
7.5
(0.3)
Seven, 1.3-dia.
holes
0.5
0.3
1
(2.1)
S
+
7
R
6
20
* Average value
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
13 max.
(12.8)*
3.5
25.5 max.
(25.2)*
(2.7)
7.5
(0.3)
Six, 1.3-dia.
holes
0.3
1
* Average value
0.5
0.16
(2.1)
S
+
7
R
6
20
* Average value
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
2.5
(28.8)*
2.5
(2.7)
25.5 max.
(25.3)*
7.5
S
+
+
10
R
9
(0.3)
(2.7)
0.3
0.18
0.18
1
0.15
* Average value
(2.1)
(2.1)
20
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
2.5
(28.8)*
2.5
(2.7)
25.5 max.
(25.3)*
7.5
S
+
+
10
R
9
(0.3)
(2.7)
0.3
1
0.18
0.15
1
(2.1)
* Average value
(2.1)
20
Note: Orientation marks are indicated as follows:
10
G2R
13 max.
(12.7)*
29 max.
(28.8)*
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
2.5
2.5
(2.7)
25.5 max.
(25.2)*
7.5
(0.3)
0.5
0.5
0.3
(2.1)
0.15
* Average value
(2.1)
20
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
13 max.
(12.7)*
29 max.
(28.8)*
2.5
2.5
(2.7)
25.5 max.
(25.2)*
7.5
(0.3)
0.5
0.3
1
20
(2.1)
0.15
G
2
R
(2.1)
* Average value
13.5 max.
(12.8)*
29 max.
(28.6)*
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
2.5
2.5
(2.7)
25.5 max.
(24.7)*
7.5
0.5
0.5
0.3
(2.1)
0.15
* Average value
(2.1)
20
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
13.5 max.
(12.8)*
29 max.
(28.6)*
2.5
2.5
(2.7)
25.5 max.
7.5
8
0.5
0.3
1
(2.1)
0.15
20
(2.1)
* Average value
11
G2R
30.5 max.
(29.7)*
5.2
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
Mounting Holes
(BOTTOM VIEW)
Tolerance: 0.1 mm
5.2
17.5
* Average value
0.5
38
Two M3 or
two 3.5 dia.
1
8.5
5
29.5 max.
45 max.
(43.9)*
14 max.
(13.1)*
30.5 max.
(29.7)*
5.2
17.4
G
2
R
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
Mounting Holes
(BOTTOM VIEW)
Tolerance: 0.1 mm
* Average value
38
0.5
Two M3 or
two 3.5 dia.
1
4
8.5
29.5 max.
2.5
45 max.
(43.9)*
14 max.
(13.1)*
12
G2R
Approved Standards
The approval rating values for overseas standards are different from the performance values determined individually. Confirm the
values before use.
File No. E41643
CSA Certified:
File No. LR31928
UL Recognized:
1-pole
1-pole
Model
Contact
form
Coil ratings
G2R-1A
G2R-1A4
G2R-1A-H
SPST-NO
(1a)
G2R-1
G2R-14
G2R-1-H
SPDT
(1c)
G2R-1AZ4
G2R-1Z
G2R-1Z4
G2R-1A-E
G2R-1-E
100,000
SPDT
(1c)
SPST-NO
(1a)
SPDT
(1c)
G2R-1A-H
6,000
G2R-1
5 A, 30 VDC (Resistive)
at 40C
Contact
form
DPST-NO
(2a)
G2R-2A-H
G2R-24
G2R-24-H
Coil ratings
Contact ratings
5 A, 250 VAC (General
Use) at 40C
100,000
G2R-14
G2R-1-H
DPDT
(2c)
Number of
test
operations
100,000
100,000
25,000
25,000
G2R-1AZ
G2R-1Z
6,000
G2R-1Z4
G2R-1A-E
SPST-NO
(1a)
SPDT
(1c)
SPST-NO
(1a)
30,000
6,000
25,000
G2R-1-E
Number of
test
operations
6,000
SPDT
(1c)
100,000
25,000
6,000
6,000
25,000
2-pole
Contact
form
Coil ratings
G2R-2A
G2R-2A4
G2R-2A-H
G2R-24
Contact ratings
5 A, 250 VAC (General
Use) at 40C
DPST-NO
(2a)
G2R-24-H
TV-3 (N. O. only) at
40C
Contact ratings
3 to 110 VDC
3 to 240 VAC 10 A, 30 VDC
(Resistive) at 40C
SPDT
(1c)
G2R-2
3 to 120 VDC 5 A, 30 VDC (Resistive)
6 to 240 VAC at 40C
G2R-2
Coil ratings
SPST-NO
(1a)
G2R-1A-T
Model
G2R-2A
G2R-2A4
G2R-1A4
G2R-1AZ4
SPST-NO
(1a)
Contact
form
G2R-1A
2-pole
Model
Model
G2R-1-T
G2R-1-T
G2R-1AZ
Number of
test
operations
G2R-1A-T
Contact ratings
Number of
test
operations
6,000
100,000
25,000
Contact
form
G2R-1(A)-E
10 A, 250 VAC
5 to 110 VDC (cos = 1.0) at 40C
12 to 240 VAC 10 A, 30 VDC (0 ms) at
40C
G2R-( )
2
Coil ratings
Contact ratings
Number of
test
operations
100,000
5 A, 250 VAC
5 to 110 VDC (cos = 1.0) at 40C
12 to 240 VAC 5 A, 30 VDC (0 ms) at
40C
Contact
form
G2R-1(A)-E
10 A, 250 VAC
3 to 120 VDC (cos = 1.0) at 70C
6 to 240 VAC 10 A, 30 VDC (0 ms) at
70C
G2R-( )
2
Coil ratings
Contact ratings
Number of
test
operations
100,000
5 A, 250 VAC
3 to 120 VDC (cos = 1.0) at 40C
6 to 240 VAC 5 A, 30 VDC (0 ms) at
40C
13
G
2
R
G2R
Precautions
Please refer to PCB Relays Common Precautions for correct use.
Correct Use
Mounting
When mounting a number of relays on
a PCB, be sure to provide a minimum
mounting space of 5 mm between the
two juxtaposed relays as shown
below.
5 mm
min.
Type
#187
(Width
4.75)
5 mm min.
G
2
R
Handling
The terminals are compatible with
Faston receptacle #187 and are
suitable for positive-lock mounting.
Use only Faston terminals with the
specified numbers.
Select leads for connecting Faston
receptacles with wire diameters that
are within the allowable range for the
load current.
Do not apply excessive force to the
terminals when mounting or
dismounting the Faston receptacle.
Also, do not insert terminals at an
angle, or insert/remove multiple
terminals at the same time. Be sure to
insert and remove terminals carefully
one at a time.
Receptacle
terminals
AMP170330-1
(170324-1)
AMP170331-1
(170325-1)
AMP170332-1
(170326-1)
Positive housing
AMP172074-1
(natural color)
AMP172074-4
(yellow)
AMP172074-5
(green)
AMP172074-6
(blue)
Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
OMRON Corporation
Electronic and Mechanical Components Company
14
Contact: www.omron.com/ecb