You are on page 1of 20

Data Sheet

Unicell Dust Collectors


Series C10-90

500=
required for
maintenance

400=
minimum
clearance

1150
required for
maintenance

h
Refer to
page 7

d=

Lifting bracket
(removable)

Fan
terminal box

Cleaned air
outlet

Refer to
page 7

Fork lifting slots


(C40, C50, C60,
C75 & C90 only)

Joint line
(C40, C50, C60,
C75 & C90 only)

Contaminated
air inlet
(may be fitted
either side)

Filter section
access door

Joint line

Controller

80 litre dust container


(800 min. req'd for bin removal.
May be removed from either side
standard position right-hand
side, as shown)

j
c

FRONT ELEVATION

SIDE ELEVATION

UNICELL DUST COLLECTOR WITH DUST CONTAINER


(C50-3 K10 illustrated)

SPECIFICATIONS
Type

Filtration
area

C10-3
C20-3
C30-3
C40-3
C50-3
C60-3
C75-3
C90-3

10m2
20m2
30m2
40m2
50m2
60m2
75m2
90m2

928
928
1280
1240
1240
1240
1240
1240

1380
1380
1380
2100
2100
2100
2100
2100

1380
1380
1380
1920
1920
1920
1920
1920

185
185
185
120
120
120
120
120

Refer to page 9 for fan availability

DIMENSIONS in mm
e
f
g
814
814
814
1475
1475
1475
2000
2000

1040
1040
1040
1100
1100
1100
1100
1100

1170
1170
1170
1780
1780
1780
1780
1780

1667
1667
1667
2288
2288
2288
2765
2765

785
785
785
1210
1210
1210
1210
1210

= Refer also to page 19 for clearances required for fan removal

Publication 2710C (GB) 0803


Donaldson Torit DCE reserve the right to alter design without notice.

12
12
12
2
2
2
2
2

Freedom from patent restrictions must not be assumed.

Data Sheet
Unicell Dust Collectors Series C10-90

500=
required for
maintenance

400=
minimum
clearance

1150
required for
maintenance

d=

Lifting bracket
(removable)
Cleaned air
outlet

Refer to
page 7

Fan terminal box


g
Joint line
(C40, C50, C60,
C75 & C90 only)
e

Contaminated
air inlet
(may be fitted
either side)

Filter section
access door
Joint line
Controller
i
f

k
Rotary valve
(optional)
l

=
c

FRONT ELEVATION

SIDE ELEVATION

UNICELL DUST COLLECTOR WITH ROTARY VALVE


(C20 R K3 illustrated)

SPECIFICATIONS
Type

Filtration
area

C10 R

10m2

928

1380

1380

185

814

C20 R

20m

928

1380

1380

185

814

1924

12

1170

2551

785

325

1200

C30 R

30m2

1280

1380

1380

185

814

1924

12

1170

2551

785

325

1200

C40 R

40m2

1240

2100

1920*

120

1475

2182

1780

3370

1210

380

1206

C50 R

50m2

1240

2100

1920*

120

1475

2182

1780

3370

1210

380

1206

C60 R

60m2

1240

2100

1920*

120

1475

2182

1780

3370

1210

380

1206

C75 R

75m

1240

2100

1920*

120

2000

2182

1780

3847

1210

380

1206

C90 R

90m2

1240

2100

1920*

120

2000

2182

1780

3847

1210

380

1206

DIMENSIONS in mm
f
g
h
1924

12

1170

2551

785

325

1200

Refer to page 9 for fan availability


Refer also to page 19 for clearances required for fan removal
*Measurement from front of collector

Data Sheet
Unicell Dust Collectors Series C10-90

500=
required for
maintenance

400=
minimum
clearance

1150
required for
maintenance

d=

Lifting bracket
(removable)
Cleaned air
outlet

Refer to
page 7

Fan terminal box


g
Joint line
(C40, C50, C60,
C75 & C90 only)
e
Filter section
access door
f

Contaminated
air inlet
(may be fitted
either side)

Controller

FRONT ELEVATION

SIDE ELEVATION

UNICELL HOPPER TYPE DUST COLLECTOR


(C20 H K3 illustrated)

SPECIFICATIONS
Filtration
area

C10 H

10m2

928

1380

1215

185

814

325

C20 H

20m2

928

1380

1215

185

814

325

C30 H

30m2

1280

1380

1215

185

814

C40 H

40m2

1240

2100

1920*

120

C50 H

50m2

1240

2100

1920*

C60 H

60m2

1240

2100

C75 H

75m2

1240

C90 H

90m2

1240

Type

DIMENSIONS in mm
e
f
g

12

1170

952

165

12

1170

952

165

325

12

1170

952

165

1475

1780

1188

120

1475

1780

1188

1920*

120

1475

1780

1188

2100

1920*

120

2000

1780

1665

2100

1920*

120

2000

1780

1665

Refer to page 9 for fan availability


Refer also to page 19 for clearances required for fan removal
*Measurement from front of collector

DESIGN LIMITS (standard equipment)


Temperature range: -10 to +60C
Pressure limits:

Collector with fan: as fan performance curves from shut-off to operating pressure
Collector without fan: -500mm W.G. (For positive pressures refer to Torit DCE)

Dimension tolerances:

5mm on main dimensions; 2mm on detail dimensions

Equipment suitable for use in a potentially explosive atmosphere (Directive 94/9/EC)


satisfying the requirements for group II category 2D and 3D T125C is available

Data Sheet
Unicell Dust Collectors Series C10-90

A
Cleaned air
outlet

400
minimum
clearance

1150
required for
maintenance
Lifting bracket
(removable)

e
Filter section
access door
f

Contaminated
air inlet
(may be fitted
either side)

Controller

FRONT ELEVATION

SIDE ELEVATION

UNICELL VENTING TYPE DUST COLLECTOR


(C20 V illustrated)

SPECIFICATIONS
Type

Filtration
area

DIMENSIONS in mm
e
f
g

C10 V

10m2

928

1380

1215

185

C20 V

20m

928

1380

1215

185

814

325

C30 V

30m2

1280

1380

1215

185

814

325

C40 V

40m2

1240

2100

1920*

120

1675

C50 V

50m

1240

2100

1920*

120

1675

C60 V

60m2

1240

2100

1920*

120

1675

C75 V

75m

1240

2100

1920*

120

C90 V

90m2

1240

2100

1920*

120

1170

952

165

12

1170

952

165

12

1170

952

165

1780

1188

1780

1188

1780

1188

2200

1780

1665

2200

1780

1665

814

325

12

*Measurement from front of collector

ELECTRICAL REQUIREMENTS
C10: 2-way controller
C20 and C40:

4-way controller

C50 and C75:

5-way controller

C30, C60 and C90:

6-way controller

Controller voltage input:


Fan motor:

AC version: 105-120V, 200-240V 10%

To suit local voltage

DC version: 24V

Data Sheet
Unicell Dust Collectors Series C10-90

A
Cleaned air
outlet

400
minimum
clearance

1150
required for
maintenance
Lifting bracket
(removable)

Contaminated
air inlet
(may be fitted
either side)

Filter section
access door
Joint line
(C40, C50, C60,
C75 & C90 only)

i
Controller
f

80 litre dust container


(800 min. req'd for bin removal.
May be removed from either side
standard position right-hand
side, as shown)

j
c

FRONT ELEVATION

SIDE ELEVATION

UNICELL VENTING TYPE DUST COLLECTOR WITH DUST CONTAINER


(C20-3 V illustrated)

SPECIFICATIONS
Filtration
area

C10-3 V

10m2

928

1380

1380

185

C20-3 V

20m

928

1380

1380

185

814

1040

12

1170

1667

785

C30-3 V

30m2

1280

1380

1380

185

814

1040

12

1170

1667

785

C40-3 V

40m2

1240

2100

1920*

120

1675

1100

1780

2288

1210

C50-3 V

50m2

1240

2100

1920*

120

1675

1100

1780

2288

1210

C60-3 V

60m2

1240

2100

1920*

120

1675

1100

1780

2288

1210

C75-3 V

75m

1240

2100

1920*

120

2200

1100

1780

2765

1210

C90-3 V

90m2

1240

2100

1920*

120

2200

1100

1780

2765

1210

Type

DIMENSIONS in mm
e
f
g
814

1040

12

1170

1667

785

*Measurement from front of collector

DUST CONTAINER
Typical dust densities
SIZE
80 litre
80 litre
(3 cu.ft.)

Approx
net weight
6 kg

A reasonable total load for


removal by hand would be 25 kg

Dust
Sander
Graphite
Sand
Iron
Steel

Density with 50%


voidage, in kg/litre
0.13
0.80
1.33
3.58
3.72

Data Sheet
Unicell Dust Collectors Series C10-90

A
Cleaned air
outlet

400
minimum
clearance

1150
required for
maintenance
Lifting bracket
(removable)

Contaminated
air inlet
(may be fitted
either side)

Filter section
access door
Joint line
Controller
i
f

k
Rotary valve
(optional)
l

FRONT ELEVATION

SIDE ELEVATION

UNICELL VENTING TYPE DUST COLLECTOR WITH ROTARY VALVE


(C20 VR illustrated)

SPECIFICATIONS
Type

Filtration
area

C10
C20
C30
C40
C50
C60
C75
C90

10m2
20m2
30m2
40m2
50m2
60m2
75m2
90m2

928
928
1280
1240
1240
1240
1240
1240

1380
1380
1380
2100
2100
2100
2100
2100

1380
1380
1380
1920*
1920*
1920*
1920*
1920*

185
185
185
120
120
120
120
120

814
814
814
1675
1675
1675
2200
2200

VR
VR
VR
VR
VR
VR
VR
VR

DIMENSIONS in mm
f
g
h
1924
1924
1924
2182
2182
2182
2182
2182

12
12
12
2
2
2
2
2

1170
1170
1170
1780
1780
1780
1780
1780

2551
2551
2551
3370
3370
3370
3847
3847

785
785
785
1210
1210
1210
1210
1210

325
325
325
380
380
380
380
380

1200
1200
1200
1206
1206
1206
1206
1206

*Measurement from front of collector

DIMENSIONS in mm
B

C10, C20 and C30

340

200

280

C40, C50, C60,


C75 and C90

395

250

350

Type

8 holes
on C p.c.d.

ROTARY VALVE OUTLET FLANGE DETAILS


(for rotary valve supplied by Torit DCE)
All holes 14mm for M12 bolts. Flange is 10mm thick

Data Sheet
Unicell Dust Collectors Series C10-90

Access door
(Collectors fitted with
optional secondary or
absolute filter only)

FRONT ELEVATION

SIDE ELEVATION

UNICELL DUST COLLECTOR INCLUDING DETAILS FOR


OPTIONAL SECONDARY OR ABSOLUTE FILTER
(C50 K10 with secondary filter illustrated)
All other dimensions are as indicated on pages 1 to 3, depending on the type of collector

SPECIFICATIONS
Fan type
(Refer to page 9 for fan availability)

Type

DIMENSIONS in mm
A
B

C10, C20 and C30


Unit only and unit with
secondary or absolute filter

K3, K5, K7, G8, K10 or K11

764

1380

Unit only

K10 or K11
K15, K18 or K21

1025
1225

1210
1620

Unit with secondary filter


or absolute filter

K10* or K11*
K15, K18 or K21

1025
1225

1690
2100

C40, C50, C60, C75 and C90

*Secondary or absolute filters are not available for C60 collectors fitted with K10 type fan,
or for C60, C75 and C90 collectors fitted with K11 type fan

A
F holes G
for H setscrews
E

E
25

Type
A

C pitches @
D pitch centres

C pitches @
D pitch centres

C10, C20 and C30

320 mm 200 mm

90 mm 60 mm

12

12 mm

M10

C40, C50, C60,


C75 and C90

352 mm 252 mm

151 mm 50 mm

14 mm

M12

25
25

25

HOPPER OUTLET FLANGE DETAILS FOR ROTARY VALVE


(C10-30 illustrated)

Data Sheet
Unicell Dust Collectors Series C10-90

400

STATIC PRESSURE AT FAN INLET (mm W.G.)

350

300

250

200

150

100

50

1000

2000

3000

4000

5000

AIR VOLUME (m3/h)

C10, C20 and C30 dust collectors

500

450

STATIC PRESSURE AT FAN INLET (mm W.G.)

400

350

300

250

200

150

100

50

2000

4000

6000

8000

AIR VOLUME (m3/h)

C40, C50, C60, C75 and C90 dust collectors

FAN PERFORMANCE CURVES

10000

12000

Data Sheet
Unicell Dust Collectors Series C10-90

FAN SELECTION
These curves indicate static pressure available at fan inlet for a given volume when fitted inside a
Unicell dust collector.
To select the most suitable fan for a given application:
1

Determine the air volume, in m3/h, needed to entrain the dust.

Read off the unit resistance, in mm W.G., at air volume required.

Estimate pressure drop through connected system - i.e. between point of entrainment and collector inlet.

Assess pressure drop over dust collector prior to cleaning, usually 50 to 125 mm W.G.

The sum of 2, 3 and 4 = W.G. required.

Consult graph for fan performances available.

FAN AVAILABILITY
Fan type:
Motor rating:
C10 and C20
C30
C40
C50
C60
C75 and C90

K3
1.5 kW

K5
2.2 kW

K7
3.0 kW

G8
5.5 kW

4
4
8
8
8
8

4
4
8
8
8
8

4
4
8
8
8
8

4
4
8
8
8
8

An acoustic diffuser is fitted as standard

K10
5.5 kW

K11
7.5 kW

8
4
4
4
4T
8

8
4
4
4
4T
4T

K15
11.0 kW

K18
15.0 kW

K21
18.5 kW

8
8
4
4
4
4

8
8
8
4
4
4

8
8
8
8
8
4

T Not available with secondary or absolute filter

NOISE LEVELS
Machinery noise levels are an important consideration in the design and selection of new equipment.
Several EC Directives and National Laws/Regulations adopting these directives make reference to airborne noise emissions.
Actions that employers are required to comply with if employees are subjected to a daily personal noise
exposure Lep,d of 85 dB(A) or more are also specified.
All Unicell dust collectors, when fitted with an acoustic diffuser, secondary filter or absolute filter,
operating an 8 hour shift, are below this action limit.

WEIGHTED SOUND PRESSURE LEVELS


All readings were taken in normal industrial areas, i.e. semi-reverberant surroundings, with local equipment silent.
Measurements were taken at maximum air flow conditions at 1.0 metre radius from the equipment housing
and 1.6 metres above base level, using a precision sound level meter and octave filter.
Collectors tested were of standard configuration i.e. with acoustic diffuser
K3
66 dB(A)

K5
72 dB(A)

K7
73 dB(A)

G8
75 dB(A)

K10
74 dB(A)

K11
76 dB(A)*

K15
79 dB(A)

Noise levels of installed equipment may vary due to site conditions

K18
81 dB(A)

*Measured data

K21
82 dB(A)

Data Sheet
Unicell Dust Collectors Series C10-90

APPROXIMATE NET WEIGHTS

Unicell dust collector with dust container


Type

Fan
type

Unit
only

Unit with
secondary
filter

Unit with
absolute
filter

C10-3

K3
K5
K7
G8

548 kg
563 kg
588 kg
603 kg

577 kg
592 kg
617 kg
632 kg

579 kg
594 kg
619 kg
634 kg

C20-3

K3
K5
K7
G8

559 kg
574 kg
599 kg
614 kg

588 kg
603 kg
628 kg
643 kg

590 kg
605 kg
630 kg
645 kg

C30-3

K3
K5
K7
G8
K10
K11

653 kg
668 kg
693 kg
708 kg
723 kg
788 kg

689 kg
704 kg
729 kg
744 kg
759 kg
824 kg

C40-3

K10
K11
K15

1124 kg
1184 kg
1279 kg

C50-3

K10
K11
K15
K18

C60-3

Unicell dust collector with rotary valve


Fan
type

Unit
only

Unit with
secondary
filter

Unit with
absolute
filter

C10 R

K3
K5
K7
G8

591 kg
606 kg
631 kg
646 kg

620 kg
635 kg
660 kg
675 kg

622 kg
637 kg
662 kg
677 kg

C20 R

K3
K5
K7
G8

602 kg
617 kg
642 kg
657 kg

631 kg
646 kg
671 kg
686 kg

633 kg
648 kg
673 kg
688 kg

700 kg
715 kg
740 kg
755 kg
770 kg
835 kg

C30 R

K3
K5
K7
G8
K10
K11

703 kg
718 kg
743 kg
758 kg
773 kg
838 kg

739 kg
754 kg
779 kg
794 kg
809 kg
874 kg

750 kg
765 kg
790 kg
805 kg
820 kg
885 kg

1198 kg
1258 kg
1363 kg

1247 kg
1307 kg
1413 kg

C40 R

K10
K11
K15

1015 kg
1075 kg
1170 kg

1089 kg
1149 kg
1254 kg

1138 kg
1198 kg
1304 kg

1134 kg
1194 kg
1289 kg
1314 kg

1208 kg
1268 kg
1373 kg
1398 kg

1257 kg
1317 kg
1423 kg
1448 kg

C50 R

K10
K11
K15
K18

1025 kg
1085 kg
1180 kg
1205 kg

1099 kg
1159 kg
1264 kg
1289 kg

1148 kg
1208 kg
1314 kg
1339 kg

K10
K11
K15
K18

1144 kg
1204 kg
1299 kg
1324 kg

1395 kg
1420 kg

1431 kg
1456 kg

C60 R

K10
K11
K15
K18

1035 kg
1095 kg
1190 kg
1215 kg

1286 kg
1311 kg

1322 kg
1347 kg

C75-3

K11
K15
K18
K21

1389 kg
1484 kg
1509 kg
1614 kg

1580 kg
1605 kg
1710 kg

1616 kg
1641 kg
1746 kg

C75 R

K11
K15
K18
K21

1280 kg
1375 kg
1400 kg
1505 kg

1689 kg
1714 kg
1819 kg

1725 kg
1750 kg
1855 kg

C90-3

K11
K15
K18
K21

1404 kg
1499 kg
1524 kg
1629 kg

1595 kg
1620 kg
1725 kg

1631 kg
1656 kg
1761 kg

C90 R

K11
K15
K18
K21

1295 kg
1390 kg
1415 kg
1520 kg

1704 kg
1729 kg
1834 kg

1740 kg
1765 kg
1870 kg

Type

All weights shown indicate heaviest configuration

10

Data Sheet
Unicell Dust Collectors Series C10-90

APPROXIMATE NET WEIGHTS

Unicell venting type dust collector


Type

Fan
type

Unit
only

Unit with
secondary
filter

Unit with
absolute
filter

C10
C20
C30
C40
C50
C60
C75
C90

208 kg
219 kg
281 kg
530 kg
540 kg
550 kg
735 kg
750 kg

Unicell hopper type dust collector


Fan
type

Unit
only

Unit with
secondary
filter

Unit with
absolute
filter

C10 H

K3
K5
K7
G8

418 kg
433 kg
458 kg
473 kg

442 kg
457 kg
482 kg
497 kg

444 kg
459 kg
484 kg
499 kg

C20 H

K3
K5
K7
G8

429 kg
444 kg
469 kg
484 kg

453 kg
468 kg
493 kg
508 kg

455 kg
470 kg
495 kg
510 kg

C30 H

K3
K5
K7
G8
K10
K11

513 kg
528 kg
553 kg
568 kg
583 kg
648 kg

549 kg
564 kg
589 kg
604 kg
619 kg
684 kg

560 kg
575 kg
600 kg
615 kg
630 kg
695 kg

C40 H

K10
K11
K15

805 kg
865 kg
960 kg

879 kg
939 kg
1044 kg

928 kg
988 kg
1094 kg

C50 H

K10
K11
K15
K18

815 kg
875 kg
970 kg
995 kg

889 kg
949 kg
1054 kg
1079 kg

938 kg
998 kg
1104 kg
1129 kg

C60 H

K10
K11
K15
K18

825 kg
885 kg
980 kg
1005 kg

1076 kg
1101 kg

1112 kg
1137 kg

C75 H

K11
K15
K18
K21

1070 kg
1165 kg
1190 kg
1295 kg

1479 kg
1504 kg
1609 kg

1515 kg
1540 kg
1645 kg

C90 H

K11
K15
K18
K21

1085 kg
1180 kg
1205 kg
1310 kg

1494 kg
1519 kg
1624 kg

1530 kg
1555 kg
1660 kg

Type

V
V
V
V
V
V
V
V

Unicell venting type dust collector


with dust container
Type

C10-3
C20-3
C30-3
C40-3
C50-3
C60-3
C75-3
C90-3

V
V
V
V
V
V
V
V

Fan
type

Unit
only

Unit with
secondary
filter

Unit with
absolute
filter

338 kg
349 kg
421 kg
849 kg
859 kg
869 kg
1054 kg
1069 kg

Unicell venting type dust collector


with rotary valve
Type

Fan
type

Unit
only

Unit with
secondary
filter

Unit with
absolute
filter

C10
C20
C30
C40
C50
C60
C75
C90

381 kg
392 kg
471 kg
740 kg
750 kg
760 kg
945 kg
960 kg

VR
VR
VR
VR
VR
VR
VR
VR

All weights shown indicate heaviest configuration

11

Data Sheet
Unicell Dust Collectors Series C10-90

205
Compressed
air inlet
(" B.S.P. Parallel)

270

117

Compressed
air inlet
(" B.S.P. Parallel)

255

SIDE ELEVATION

SIDE ELEVATION

C40-90 hopper and venting type collectors


and all C40-90 collectors supplied with PT controller
or optional compressed air assembly

All C10-30 collectors

50
Joint line

Compressed
air inlet
(" B.S.P. Parallel)
212

267

FRONT ELEVATION

SIDE ELEVATION

C40-90 standard and venting type collectors with dust container or rotary valve*
*For C40-90 collectors supplied with PT controller or optional compressed air assembly, refer to illustration at top-right of page

POSITION OF COMPRESSED AIR CONNECTION TO COLLECTOR

COMPRESSED AIR REQUIREMENTS


Atmospheric
air volume - F.A.D. b
at 12 sec. intervals c

Type

Working compressed
air pressure a

C10

4.2 bar

60 psig

9.1 m3/h

5.4 cfm

200 millisec.

C20

4.2 bar

60 psig

9.1 m3/h

5.4 cfm

200 millisec.

7.1 cfm

200 millisec.

C30
a

4.2 bar

60 psig

12.0 m /h

Pulse duration

b
Normal operating pressure
Recommended atmospheric air volume of clean, dry compressed air
c
Recommended initial settings; these may be varied with experience

12

Data Sheet
Unicell Dust Collectors Series C10-90

(C10-30) 23
(C40-95) 13

23 (C10-30)
13 (C40-95)
Compressed
air inlet
(" B.S.P. Parallel)

170
Pressure
gauge

Pressure
relief valve

(C10-30) 137
(C40-95) 127
Pressure
relief valve

170
Pressure
relief valve

Pressure
gauge

Compressed
air inlet
(" B.S.P. Parallel)

Pressure
gauge

Compressed air inlet


(" B.S.P. Parallel)

23 (C10-30)
13 (C40-95)
Compressed
air inlet
(" B.S.P. Parallel)

(C10-30) 23
(C40-95) 13
Compressed
air inlet
(" B.S.P. Parallel)

(C10-30) 137
(C40-95) 127
170

170
Moisture separator
with pressure gauge

Moisture separator
with pressure gauge

Moisture separator
with pressure gauge

Compressed air inlet


(" B.S.P. Parallel)

Pressure
relief valve

(C10-30) 93
(C40-95) 83

93 (C10-30)
83 (C40-95)
Pressure
relief valve

(C10-30) 237
(C40-95) 227

Compressed
air inlet
(" B.S.P. Parallel)

Pressure
relief valve

Compressed
air inlet
(" B.S.P. Parallel)

170

170

Moisture separator
with pressure gauge

Moisture separator
with pressure gauge

Moisture separator
with pressure gauge

Compressed air inlet


(" B.S.P. Parallel)

PLAN ELEVATIONS

OPTIONAL COMPRESSED AIR ASSEMBLY DETAILS SHOWING ALTERNATIVE ARRANGEMENTS

COMPRESSED AIR REQUIREMENTS


Atmospheric
air volume - F.A.D. b
at 12 sec. intervals c

Type

Working compressed
air pressure a

C40

5.2 bar

75 psig

17.1 m3/h

10.1 cfm

200 millisec.

C50

5.2 bar

75 psig

17.1 m3/h

10.1 cfm

200 millisec.

Pulse duration

C60

5.2 bar

75 psig

17.1 m /h

10.1 cfm

200 millisec.

C75

6.2 bar

90 psig

20.8 m3/h

12.2 cfm

200 millisec.

12.2 cfm

200 millisec.

C90
a

6.2 bar

90 psig

20.8 m /h

Normal operating pressure


Recommended atmospheric air volume of clean, dry compressed air
c
Recommended initial settings; these may be varied with experience

13

Data Sheet
Unicell Dust Collectors Series C10-90

646

E
J

For collectors with


dust container, fix base
with suitable bolts
(4 holes 12mm)

400

FRONT OF COLLECTOR

8 holes 22mm
for M12 foundation bolts

E
K

J
J

FOUNDATION DETAILS FOR STANDARD AND VENTING TYPE COLLECTORS


WITH DUST CONTAINER OR ROTARY VALVE
(C40-90 illustrated)

DIMENSIONS in mm
F
G

Type

C10

928

1380

1038

1490

55

264

272

462

20

157

684

1136

C20

928

1380

1038

1490

55

264

272

462

20

157

684

1136

C30

1280

1380

1390

1490

55

440

272

462

20

157

1036

1136

C40

1240

1920*

1360

2040

60

420

387

887

25

152

1006

1686

C50

1240

1920*

1360

2040

60

420

387

887

25

152

1006

1686

C60

1240

1920*

1360

2040

60

420

387

887

25

152

1006

1686

C75

1240

1920*

1360

2040

60

420

387

887

25

152

1006

1686

C90

1240

1920*

1360

2040

60

420

387

887

25

152

1006

1686

*Measurement from front of collector

14

Data Sheet
Unicell Dust Collectors Series C10-90

8 pitches @ 140 mm

27.5

27.5
40

FRONT OF COLLECTOR

(C10 and C20) 69


(C30) 60

20

5 pitches
@ 150 mm
(C10 and C20)
8 pitches
@ 140 mm
(C30)

848 Aperture
(C10 and C20)
1200 Aperture
(C30)

(C10 and C20) 69


(C30) 60
20

40

165

40

1135 Aperture

40

C10, C20 and C30


(C10 and C20 illustrated)

55

4 pitches @ 155 mm

70

5 pitches @ 155 mm

90
100

100
55
25

52
50
135 155 180

17

Hopper joint flange*


1240

1140
Aperture

6 pitches
@ 155 mm
25

50

880

Broken lines indicate


extra fixings required
when customer supplies
own support structure

25

1320 Aperture

FRONT OF COLLECTOR

80

80
75

50

75
80

80
25

135 155

180

50
1420

497

C40, C50, C60, C75 and C90


*NOTE: Access will be required to the underside of the hopper joint flange, e.g. via customer upstand

APERTURE AND MOUNTING FLANGE DETAILS FOR HOPPER AND VENTING TYPE COLLECTORS
All holes 12mm for M10 set screws

15

Data Sheet
Unicell Dust Collectors Series C10-90

3 pitches
@ 115 mm

60
120

59

150

120

145

252

66

10

10
10

2 pitches
@ 150 mm

10

4 pitches
@ 150 mm

145

10

C10, C20 and C30

10

C40, C50, C60, C75 and C90


with K10 or K11 type fans

105

2 pitches
@ 150 mm

105

225
66

6.5

5 pitches
@ 150 mm

10

10

6.5

C40, C50, C60, C75 and C90 with K15, K18 or K21 type fans

CLEANED AIR OUTLET DETAILS FOR STANDARD AND HOPPER TYPE COLLECTORS
(with outlet grille removed)
All holes threaded for M6 set screws

16

Data Sheet
Unicell Dust Collectors Series C10-90

150

45
2 pitches
@ 120 mm

45

65
180

40

47

70 (C10 and C20)


95 (C30)

(C10 and C20) 169


(C30) 170

3 pitches
@ 150 mm
(C10 and C20)
5 pitches
@ 150 mm
(C30)
20

5 pitches
@ 150 mm

800

22
70 (C10 and C20)
95 (C30)
47

40

TOP VIEW
12

C10, C20 and C30

40

(C10 and C20 illustrated)


All holes 10mm for M8 set screws

196

40

TOP VIEW

C40, C50, C60, C75 and C90


Flange projects 48mm above top of collector
All holes 12mm for M10 set screws

CLEANED AIR OUTLET DETAILS FOR VENTING TYPE COLLECTORS

C holes
on D p.c.d.
(off centre)

Type

C10, C20 and C30

307 mm

250 mm

292 mm

C40, C50 and C60

414 mm

355 mm

405 mm

C75 and C90

521 mm

450 mm

12

497 mm

p.c.d. to DIN 24154/2

CONTAMINATED AIR INLET DETAILS


(C10-60 illustrated)
All holes 12mm for M10 bolts

17

FRONT OF COLLECTOR

20

FRONT OF COLLECTOR

22

Data Sheet
Unicell Dust Collectors Series C10-90

5 pitches @ 150 mm
(C10 and C20)
7 pitches @ 150 mm
(C30)

(C10 and C20) 72


(C30) 98
40

72 (C10 and C20)


98 (C30)
29

25

25
'MEMBREX' EXPLOSION
RELIEF MEMBRANE

758

5 pitches
@ 150 mm

MEMBRANE RETAINING FRAME

12 to joint line for collectors


with dust container
or rotary valve
337 to seating level
for hopper and venting
type collectors

29

40

844 (C10 and C20)


1196 (C30)

40

40

C10, C20 and C30


(C10 and C20 illustrated)
Mounting flange projects 60mm beyond rear of collector
All holes 10mm for M8 set screws

15

15

50
15 44 (C40, C50 and C60)
81.5 (C75 and C90)

40

6 pitches
@ 150 mm
(C40, C50 and C60)
9 pitches
@ 150 mm
(C75 and C90)

(C40, C50 and C60) 1018


(C75 and C90) 1543
'MEMBREX' EXPLOSION
RELIEF MEMBRANE

938 (C40, C50 and C60)


1463 (C75 and C90)

MEMBRANE RETAINING FRAME

83

7 pitches @ 150 mm

83

44 (C40, C50 and C60)


15 81.5 (C75 and C90)

40
312 to joint line for collectors
with dust container or rotary valve,
or to seating level for hopper and
venting type collectors

1216

C40, C50, C60, C75 and C90

FLANGE SECTION

(C40, C50 and C60 illustrated)


All holes 12mm for M10 set screws

REAR EXPLOSION RELIEF FLANGE MOUNTING DETAILS

18

Data Sheet
Unicell Dust Collectors Series C10-90
B=
minimum clearance required
for removal of fan from rear
A=
minimum clearance
required for removal of fan
from left-hand side

A=
minimum clearance
required for removal of fan
from right-hand side

C=
minimum clearance
required for removal of
fan from above

200=
minimum clearance required for
removal of fan from side or rear

FRONT ELEVATION

SIDE ELEVATION

UNICELL FAN REMOVAL DETAILS


(C50 K10 illustrated)

Fan assembly type:

=
Dimension B=:
Dimension C=:
Dimension A :

Weight:

K3

K5

K7

G8

K10

K11

K15

K18

K21

590 mm

590 mm

565 mm

690 mm

695 mm

720 mm

910 mm

930 mm

930 mm

590 mm

590 mm

640 mm

655 mm

695 mm

725 mm

965 mm

1015 mm 1015 mm

700 mm

700 mm

700 mm

605 mm

780 mm

830 mm

1005 mm 1025 mm 1025 mm

55 kg

70 kg

95 kg

110 kg

125 kg

185 kg

240 kg

265 kg

370 kg

= Measurements are for removal of fan assembly only and do not include clearances required for lifting equipment
All weights shown indicate heaviest configuration

19

www.toritdce.com
www.donaldson.com

Humberstone Lane
Thurmaston
Leicester LE4 8HP
England

Research Park Zone 1


Interleuvenlaan 1
B-3001 Leuven (Heverlee)
Belgium

Tel +44 (0)116 269 6161


Fax +44 (0)116 269 3028

Tel +32 (0)16 383 970


Fax +32 (0)16 383 938

Email: toritdce.uk@mail.donaldson.com Email: toritdce.be@mail.donaldson.com

You might also like