IRA-4SS Automatic Insertion Instrument Regulator


Welker Probe Regulators are designed to provide your chromatograph, H2S analyzer, thermtitrator,
moisture analyzers, gravitometer, calorimeter, or other on-line gas analyzers with a properly
conditioned sample stream. These regulators are designed with the point of regulation near the tip of
the probe in the flowing stream. The natural temperature drop that occurs at the point of regulation
(Joule-Thomson effect) is offset by the thermal fins on the probe tip. When used with an isolation
valve, the IRA-4SS can be completely installed or removed without interrupting pipeline flow or
operations. The IRA-4SS is another Welker Innovative and Patented Product designed to
improve the profitability of your company.
Features
!

Patented Automatic Insertion Device allows insertion and


removal of the probe from a high pressure pipeline through a

full
!
!
!
!
!
!
!
!

open isolation valve without pipeline shutdown (specify insertion


length).
Provides a regulated sample supply to chromatographs, H2S
analyzers, gravitometers, calorimeters, moisture analyzers, and
other on-line analyzing equipment.
Diaphragm design for increased low pressure output sensitivity.
Probe design inhibits carry-over of free liquids into instrument
supply system.
Thermal fins on probe offset temperature change at point of
regulation and provide sample conditioning.
316 stainless steel construction.
Manufactured under U.S. Patent #4,346,611.
Oil pot for smooth and safe insertion and retraction.
Range springs available for 0-25 psi (0-1.7 Bar), 0-50 psi (0-3.5
TYPICAL INSTALLATION
Outlet
Gauge
Port

Analytical
Equipment
(Chromatograph)

High
Capacity
Relief
Port

Sample Conditioning System

Full Open
Isolation Valve
(O 1" Internal Min.)
Length to
specify with
order

Probe tip should be


in the center 1/3 of
the pipe

Technical Data
(Standard)

Application
The IRA-4SS can be used with all products that
are compatible with the materials of construction
and seal material. High capacity downstream
relief is recommended.
Pressure Rating
Line pressures up to 2160 psi (149 Bar). Higher
pressure ratings available. Outlet pressure
ranges 0-25 psi (0-1.7 Bar), 0-50 psi (0-3.5 Bar),
and 20-100 psi (1.4-6.9 Bar).
Temperature Rating
o
o
From -20 to +400 F (-29 to +204 C).
Insertion Length
18" (457 mm) insertion travel standard, other
insertion lengths available in 6" (152 mm)
increments.
Flow Data
CV - .092.
Inlet Filter
30-35 Micron.

Materials
316 stainless steel construction with Viton seals
and PTFE seats for pressure under 1800 psi (124
Bar). Over 1800 psi, seat is Kel-f material.
Connections
Pipeline connections are 1" MNPT standard with
flange connections available upon request.
Outlet, gauge and relief valve connections are "
FNPT.
Weight (Standard 1" NPT, 18" insertion)
16 lbs.
7.2 Kg.
Non-standard designs available upon request
Options Available (not limited to)
!
!
!
!

Other materials available


2", 3" or 4" flanged connections 300#, 600#,
900#, or 1500# RF/RTJ
Working pressure up to 5000 psi (345 Bar)
Certificates (material 3.1B, hydro,
functional, conformity, etc.)

" NPT Relief


Valve Port
(not shown)

" NPT
Gauge
Port

Other Welker Products


" NPT Port

Insertion Length
Adjustment Collar

Oil Pot

47" for 18" Insertion


(fully retracted)
(1194 mm)

!
!
!
!
!
!
!
!

Automatic Liquid Shut-Off


Vent Check Valves
Liquid Eliminators
Filters
Sampling Systems
Chemical Injection Systems
Control Valves
Custom Designs

Distributed By:

1" NPT
Pipeline
Connection
Standard

Thermal
Fins

Probe Tip O.D.


0.7" (17 mm)

Engineering Company

P.O. Box 138

1 (281) 491-2331

Sugar Land, Texas 77487-0138

1-800-PRO-SAMP

Domestic Fax: 1 (281) 491-8344

International Fax: 1 (281) 242-5623

WELKER ... When excellence counts!

prosamp@welkereng.com
www.WelkerEng.com
IRA4SS-2
Rev A (6/97)
IRA-4SS.CDR

You might also like