Application Note
CM3010
Two-Channel Microlog
Input Setup
From the 4:Analyzer menu, select 2:Input Setup
(Figure 2).
In the Input Setup screen, the important fields to
set are Type: Acceleration (if you are using an
accelerometer dont integrate the signal) and Full
Scale: 10.
NOTE: If an overload occurs during data
collection, increase the full scale setting
with the up arrow key.
Single-Channel Microlog
Spectrum Setup
From the Analyzer menu, select Spectrum
Setup to display the screen of Figure 3.
The important fields to set in Spectrum Setup
are Average Type: Pk Hold, Average Mode:
Cont., and Window:Uniform. The peak hold
averaging technique will hold the highest
amplitude value for each frequency line.
Continuous averaging will allow updating of the
captured signal as required.
Two-Channel Microlog
Measment Setup
From the 4:Analyzer menu, select 3:Measment
Setup to display the screen of Figure 4.
"How to Bump
Test with the
Microlog"
Single-Channel Microlog
Display Setup
From the Analyzer menu, select Display Setup
(Figure 5).
A Display Setup with dual display of magnitude
and time allows you to clearly see the results of the
test and spot a bad impact or bump.
Single-Channel Microlog
Trigger Setup
Asia, Pacific
153 Gul Circle, Jurong
Singapore 629610
Telephone (+65) 861-6922
FAX (+65) 861-3044
Two-Channel Microlog
Trigger Setup
From the 4:Analyzer menu, select 5:Trigger Setup
(Figure 7).
RESULTING SPECTRUM
TIME WAVEFORM