You are on page 1of 6

AXIAL FANS

Series

Series

Series

VENTS OV

VENTS OVK

VENTS VKF

Low pressure axial fans


in the steel casing with the air
capacity up to 100 m3/h
for wall mounting

Low pressure axial fans


in the steel casing with the air
capacity up to 100 m3/h
for wall mounting

Low pressure axial fans


in the steel casing with the air
capacity up to 11900 m3/h
for vent duct mounting

Applications
Combined supply and exhaust ventilation systems for

Motor
The impellers are powered by two- or three-pole,

Mounting
Fan is installed on the wall surface by means of a

various premises where high air capacity at relatively


low system resistance is required. OV and OVK fans
can be used for the direct air exhaust or pressurization

single- or three-phase asynchronous motors with


external rotor and built-in thermal overheating
protection depending on the model. Ball bearings in

square (OV series) or round (OVK series) mounting


plate. VKF fan is installed into the duct by means
of connecting flanges. The fan is powered through

in smoke ventilation systems. OV and OVK fan are

the motor provide long service life designed for at

the external remote terminal box. Power supply and

suitable for outdoor wall mounting.

least 40 000 hours. Motor protection rating IP 44.

installation shall be performed in compliance with the


manual and wiring diagram on the terminal box.

Design
The fan casing and the impeller are made of steel with
polymeric coating. OV and OVK fan terminal box is
equipped with the cord for remote connection. VKF
fan is fitted with the external terminal box mounted
on the fan casing.

Speed control
Both smooth or step speed control is performed by
means of the thymistor or autotransformer controller.
Several fans can be connected to one controller if the
total power and operating current do not exceed the
rated controller values.

Designation key:
Series and modification

Motor modification

VENTS OV square mounting plate


VENTS OVK round mounting plate
VENTS VKF mounting into a vent duct

Number of poles

Phase

2
4
6

E single phase
D three phases

Accessories

page 398

156

page 407

page 407

page 408

Dimension type

page 411

page 412

200; 250; 300; 350; 400;


450; 500; 550; 630

WWW.VENTILATION-SYSTEM.COM

Technical data:

Voltage [V / 50 Hz]

OV /
VK /
VKF
2 200

OV /
VK /
VKF
2 250

OV /
VK /
VKF
2D 250

OV /
VK /
VKF
4 250

OV /
VK /
VKF
4D 250

OV /
VK /
VKF
2 300

230

230

3~ 400

230

3~ 400

230

Power [W]

55

80

80

50

60

145

Current [A]

0.26

0.4

0.22

0.22

0.17

0.66

Max. air capacity [m3/h]

860

1050

1060

800

850

2230

RPM [min-1]

2300

2400

2600

1380

1400

2300

50

60

60

55

55

60

-30 +60

-30 +60

-30 +60

-30 +60

-30 +60

-30 +60

IP 24
(VKF IP X4)

IP 24
(VKF IP X4)

IP 24
(VKF IP X4)

IP 24
(VKF IP X4)

IP 24
(VKF IP X4)

IP 24
(VKF IP X4)

OV /
VK /
VKF
2D 300

OV /
VK /
VKF
4 300

OV /
VK /
VKF
4D 300

OV /
VK /
VKF
4 350

OV /
VK /
VKF
4D 350

OV /
VK /
VKF
4 400

3~ 400

230

3~ 400

230

3~ 400

230

145

75

75

140

140

180

Noise level at 3 m [dBA]

Transported air temperature [ C]


Protection rating

Voltage [V / 50 Hz]
Power [W]
Current [A]

0.25

0.35

0.22

0.65

0.38

0.82

Max. air capacity [m3/h]

2310

1340

1310

2500

2520

3580

RPM [min-1]

2350

1350

1380

1380

1380

1380

60

58

58

62

62

63

-30 +60

-30 +60

-30 +60

-30 +60

-30 +60

-30 +60

IP 24
(VKF IP X4)

IP 24
(VKF IP X4)

IP 24
(VKF IP X4)

IP 24
(VKF IP X4)

IP 24
(VKF IP X4)

IP 24
(VKF IP X4)

OV /
VK /
VKF
4D 400

OV /
VK /
VKF
4 450

OV /
VK /
VKF
4D 450

OV /
VK /
VKF
4 500

OV /
VK
4D 500

OV /
VK /
VKF
4 550

3~ 400

230

3~ 400

230

3~ 400

230

180

250

250

420

450

550

Noise level at 3 m [dBA]

Transported air temperature [ C]


Protection rating

VENTS OV
FAN SERIES VENTS VK
VENTS VKF

Technical data:

Technical data:

Voltage [V / 50 Hz]
Power [W]
Current [A]

0.47

1.2

0.6

1.95

0.9

2.55

Max. air capacity [m3/h]

3740

4680

5280

7060

6570

8800

RPM [min-1]

1380

1350

1360

1300

1300

1300

64

64

65

69

72

70

-30 +60

-30 +60

-30 +60

-30 +60

-30 +60

-30 +60

IP 24
(VKF IP X4)

IP 24
(VKF IP X4)

IP 24
(VKF IP X4)

IP 24
(VKF IP X4)

IP 24

IP 24
(VKF IP X4)

OV /
VK
4D 550

OV /
VK /
VKF
4 630

OV /
VK
4D 630

OV /
VK
6 630

3~ 400

230

3~ 400

1~ 230

750

750

800

540

Noise level at 3 m [dBA]

Transported air temperature [ C]


Protection rating
Technical data:

Voltage [V / 50 Hz]
Power [W]

1.5

3.5

1.6

2.4

Max. air capacity [m3/h]

Current [A]

9700

11900

12200

10900

RPM [min-1]

1350

1360

1320

850

Noise level at 3 m [dBA]


Transported air temperature [C]
Protection rating

73

75

78

72

-30 +60

-30 +60

-30 +60

-30 +60

IP 24

IP 24
(VKF IP X4)

IP 24

IP 24

VENTS. Industrial and commercial ventilation | 06-2013

157

AXIAL FANS
Fan overall dimensions:
Type
OV 2 200
OV 2 250 / OV 2D 250
OV 4 250 / OV 4D 250
OV 2 300
OV 2D 300
OV 4 300
OV 4D 300
OV 4 350 / OV 4D 350
OV 4 400 / OV 4D 400
OV 4 450 / OV 4D 450
OV 4 500 / OV 4D 500
OV 4 550 / OV 4D 550
OV 4 630 / OV 4D 630
OV 6 630

Dimensions [mm]
D

210
260
260
326
326
326
326
388
417
465
520
570
650
650

7
7
7
9
9
9
9
9
9
11
11
11
11
11

B1

Weight
[kg]

312
370
370
430
430
430
430
485
540
576
655
725
800
800

260
320
320
380
380
380
380
435
490
535
615
675
710
710

145
155
155
195
155
195
155
200
240
250
260
280
295
295

3.9
4.2
4.1
5.3
5.3
5.1
5.1
7.1
8.8
10.6
14.2
16.6
22.6
22.6

Weight
[kg]

145
155
155
195
155
195
155
200
240
250
260
280
295
295

2.5
3.4
3.4
4.4
4.4
4.7
4.7
6.3
8.3
9.8
12.2
15.0
20.8
20.8

OV

Fan overall dimensions:


Type
VK 2 200
VK 2 250 / VK 2D 250
VK 4 250 / VK 4D 250
VK 2 300
VK 2D 300
VK 4 300
VK 4D 300
VK 4 350 / VK 4D 350
VK 4 400 / VK 4D 400
VK 4 450 / VK 4D 450
VK 4 500 / VK 4D 500
VK 4 550 / VK 4D 550
VK 4 630 / VK 4D 630
VK 6 630

Dimensions [mm]
D

D1

D2

210
260
260
326
326
326
326
388
417
465
520
570
650
650

250
295
295
380
380
380
380
442
504
578
590
645
760
760

280
320
320
397
397
397
397
460
528
607
655
710
800
800

7
7
7
9
9
9
9
9
9
11
11
11
11
11

VK

Fan overall dimensions:


Type
VKF 2 200
VKF 2 250 / VKF 2D 250
VKF 4 250 / VKF 4D 250
VKF 2 300 / VKF 2D 300
VKF 4 300 / VKF 4D 300
VKF 4 350 / VKF 4D 350
VKF 4 400 / VKF 4D 400
VKF 4 450 / VKF 4D 450
VKF 4 500
VKF 4 550
VKF 4 630

158

Dimensions [mm]
D

D1

D2

205
260
260
310
310
362
412
462
515
565
645

235
286
286
356
356
395
438
487
541
605
674

255
306
306
382
382
421
465
515
570
636
715

d
7
7
7
7
7
9.5
9.5
9.5
9.5
11.5
11.5

Weight
[kg]

290
340
340
410
410
450
500
550
600
660
740

120
150
150
160
160
160
170
200
220
230
250

3.0
3.9
4.0
6.2 / 5.7
6.2 / 5.7
7.7
8.1
9.1
11.0
13.9
16.4

VENTS. Industrial and commercial ventilation | 06-2013

VKF

WWW.VENTILATION-SYSTEM.COM

P [Pa]

VENTS OV / VK / VKF

Pressure,

Pressure,

P [Pa]

VENTS OV / VK / VKF

Air capacity, [m3/h]

Air capacity, [m3/h]

Sound-power level
LwA to environment
Sound-power level
LwA to environment

Hz
dBA

Gen
65

63
56

125
58

Octave-frequency band [Hz]


250
500
1000 2000
58
57
59
55

Hz
dBA

Gen
76

63
68

125
66

Gen
60

63
52

125
50

Octave-frequency band [Hz]


250
500
1000 2000
68
70
68
68

8000
45

LwA to environment

Hz
dBA

250
52

500
53

1000
52

2000
52

4000
44

8000
43

Pressure,

Pressure,

P [Pa]

P [Pa]

VENTS OV / VK / VKF

Air capacity, [m3/h]

Air capacity, [m3/h]

OV / VK / VKF 2 300

OV / VK / VKF 4 350

Sound-power level
Hz
dBA

Gen
78

63
72

Octave-frequency band [Hz]


125
250
500
1000 2000
72
70
72
70
69

Gen
67

63
58

125
57

Sound-power level
4000
63

8000
63

4000
52

8000
49

OV / VK / VKF 4 300
LwA to environment

8000
58

OV / VK / VKF 4 250
4000
51

VENTS OV / VK / VKF

LwA to environment

4000
63

Hz
dBA

VENTS OV
FAN SERIES VENTS VK
VENTS VKF

OV / VK / VKF 2 250

LwA to environment

Hz
dBA

Gen
70

63
61

125
62

Gen
75

63
66

125
68

Octave-frequency band [Hz]


250
500
1000 2000
64
63
63
58

4000
56

8000
52

4000
61

8000
56

OV / VK / VKF 4 400
250
59

500
57

1000
58

2000
53

LwA to environment

Hz
dBA

VENTS. Industrial and commercial ventilation | 06-2013

250
66

500
69

1000
67

2000
65

159

AXIAL FANS

P [Pa]

VENTS OV / VK / VKF

Pressure,

Pressure,

P [Pa]

VENTS OV / VK / VKF

Air capacity, [m3/h]

Air capacity, [m3/h]

OV / VK / VKF 4 450

OV / VK / VKF 4 550

Sound-power level
LwA to environment

Hz
dBA

Gen
77

63
69

Octave-frequency band [Hz]


125
250
500
1000 2000
70
73
73
71
67

Gen
80

63
71

125
73

Sound-power level
4000
67

8000
61

4000
67

8000
63

OV / VK / VKF 4 500
LwA to environment

Hz
dBA

LwA to environment

Hz
dBA

Gen
83

63
73

125
75

Gen
77

63
71

125
73

Octave-frequency band [Hz]


250
500
1000 2000
73
75
74
72

500
74

1000
73

2000
70

LwA to environment

Hz
dBA

250
72

2000
70

4000
63

8000
59

P [Pa]

VENTS OV / VK / VKF

Air capacity, [m3/h]

OV / VK / VKF 2D 300

OV / VK / VKF 2D 250
Sound-power level
Hz
dBA

Gen
77

63
67

125
68

Gen
60

63
49

125
50

Octave-frequency band [Hz]


250
500
1000 2000
70
69
68
66

Sound-power level
4000
60

8000
57

LwA to environment

Hz
dBA

Gen
80

63
72

125
71

4000
45

8000
42

OV / VK / VKF 4D 300
Hz
LwA to environment
dBA

Gen
63

63
58

125
55

OV / VK / VKF 4D 250

160

1000
71

Pressure,

Pressure,

P [Pa]

500
73

Air capacity, [m3/h]

LwA to environment

8000
63

OV / VK / VKF 4 630
250
72

VENTS OV / VK / VKF

LwA to environment

4000
66

Hz
dBA

250
53

500
54

1000
53

2000
52

VENTS. Industrial and commercial ventilation | 06-2013

Octave-frequency band [Hz]


250
500
1000 2000
71
74
70
69

250
58

500
56

1000
58

2000
57

4000
65

8000
63

4000
52

8000
48

WWW.VENTILATION-SYSTEM.COM

P [Pa]

VENTS OV / VK / VKF

Pressure,

Pressure,

P [Pa]

VENTS OV / VK / VKF
180

V 4D 450
OVK 4D 450
VKF 4D 450
OV 4D 500
OVK 4D 500

160
140
120
100
80
60
40
20
0

1000

2000

3000

4000

5000

Air capacity, [m3/h]

OV / VK / VKF 4D 350

Air capacity, [m3/h]

Gen
72

63
62

OV / VK / VKF 4D 400
Hz
LwA to environment
dBA

Gen
75

63
65

125
66

Sound-power level
4000
56

8000
54

4000
60

8000
55

LwA to environment

Gen
76

63
65

125
68

Hz
dBA

Gen
82

63
73

125
71

4000
60

8000
57

4000
65

8000
61

OV / OVK 4D 500
250
69

500
66

1000
67

2000
64

LwA to environment

VENTS OV / VK
P [Pa]

180

OV 4D 550
OVK 4D 550
OV 4D 630
OVK 4D 630

160
140

250
75

500
78

1000
76

2000
71

VENTS OV / VK

Pressure,

P [Pa]

Octave-frequency band [Hz]


250
500
1000 2000
69
69
70
64

Hz
dBA

120

80

V 6 630
VK 6 630

70

VENTS OV
FAN SERIES VENTS VK
VENTS VKF

Hz
dBA

Octave-frequency band [Hz]


125
250
500
1000 2000
61
64
64
61
61

Pressure,

7000

OV / VK / VKF 4D 450

Sound-power level
LwA to environment

6000

60
50

100
40

80
30

60

20

40

10

20
0
4000

6000

8000

10000

0
6000

12000

7000

8000

Air capacity, [m3/h]

9000

10000

11000

Air capacity, [m3/h]

OV / VK 4D 550
Sound-power level
LwA to environment

Hz
dBA

Gen
84

63
75

125
79

Octave-frequency band [Hz]


250
500
1000 2000
72
76
71
77

4000
69

8000
68

OV / OVK 4D 630
LwA to environment

OV / OVK 6 630
Sound-power level

Hz
dBA

Gen
78

63
75

125
69

250
70

500
74

1000
74

2000
69

4000
65

8000
64

LwA to environment

Hz
dBA

Gen
75

VENTS. Industrial and commercial ventilation | 06-2013

63
51

125
56

Octave-frequency band [Hz]


250
500
1000 2000
61
65
67
66

4000
60

8000
54

161