You are on page 1of 3

INDIRECT HEATER SPECIFICATION SHEET

Project Number :
Revision:

Customer
Location
FLUID TO BE HEATED

THERMAL DESIGN
Well Head Natural Gas

TOTAL FLUID ENTERING


Gas Flow Rate
LIQUID - Water
LIQUID - Condensate Oil
Gas Temperature
Gas Density/Spec. Grav.
Liquid Water Density
Oil Density/oAPI/Sp. Gr.
Gas Viscosity
Liquid Water Viscosity
Oil Viscosity
Water Therm Conductivity
Oil Therm Conductivity
Oil Specific Heat
Water Specific Heat

INLET
5.00
40.00
2.5
100
0.6
1
52

MMScfd
Bpd
Bpd
o
F
Sp. Grav.
Sp. Grav.
oAPI
Centipoises
Centipoises
Centipoises
Btu/Hr-Ft2/oF
Btu/Hr-Ft2/oF
Btu/Lb-oF
Btu/Lb-oF

MECHANICAL DESIGN
Design Pressure:
First Coil Pressure
Second Coil Pressure
Design Temperature:
First Coil Inlet Temp.
Second Inlet Coil Temp
Crossion Allowance
Design Code (ASME, API, DOT)

OUTLET
5.00
40.00
2.5
100
0.6
1
52

Lb/hr
Lb/hr
Lb/hr

OnShore / OffShore
Seismic Zone

6,170 Psig
6,170 Psig
o
F
100
o
F
80
0.250
inch.
ASME

85

HydroCarbons
H2S

Natural Draft
Forced Draft

Yes
o
F
80
1,000
Psig
750
Psi
Natural Gas
980
Btu/Scf
Water+Ethylene Glylcol
o
F
190

ELECTRICAL DESIGN / AREA CLASSIFICATION


Power Available:
Voltage
N/A
Phase
N/A
Hertz
N/A
Area Classification:
Class
II
Division
2
Group
D
Temperature T4A
CIVIL DESIGN
Elevation, ASL
Unk.
feet
o
Ambient Temperature
95 - 110
F
Wind Speed
100
Mph

ENVIRONMENTAL DESIGN
Allowable Noise
Allowable Emissions:
NOX
CO2

Gas Coils Data:


Intermediate Choke
Post Choke Temperature
Choke Inlet Pressure
Pressure Drop (allowable)
Type of Fuel
LHV / HHV of Fuel
Bath Medium
Design Bath Temperature

dba

OnShore
4

(0 - 4)

Lb/hr
BURNER TYPE
Yes
No

ACCESSORIES
Standard Supply
Custom Design
Options:
Bath Low Level Switch
Fuel Meter
Stack High Temp Switch

Skid Mounted
Stack Type
Control Type

MISCELLANEOUS
Yes
Ell
Pneumatic

CONTROL PANEL
Required
Yes
NEC / NEMA Rating
Type
Ignitor
Yes
Burner Management
Unkn.
PLC w/B.M. & Temp Control
Unkn.

No
Yes
Yes
Yes
Yes
Page 1 of 3

Flame Arrestor

Yes

PLC W/ DCS Communications

Page 2 of 3

Unkn.

In-Line Heater Sketch:

Gas inlet

E
B

Gas outlet

C
D
G

Nozzles' Schedule:
A
B
C
D
E
F
G
H
I
J

Wellhead Gas Inlet


Gas Outlet
Fuel gas inlet
Fuel gas outlet
Temperature Indicator
Water bath Fill
Drain
Thermostat
Choke inlet
Choke outlet

Size
4"
4"
2"
2"
"
Unk.
2"
"
4"
4"

Facing
Raised Face
Raised Face
Raised Face
Raised Face
N/A
N/A
N/A
N/A
Raised Face
Raised Face

Type
Flanged
Flanged
Flanged
Flanged
Screwed
N/A
Screwed
Screwed
Flanged
Flanged

Class
2500 #
150 #
150 #
150 #
3000 #
N/A
150 #
3000 #
2500 #
150 #

ADDITIONAL NOTES:
1. All process coils are to be removable
2. Designer / Fabricator to state max. design heating Flux on fire tube
3. Unit to be skid mounted and complete for field installation and hook up.
4.Unit shall have pre-piped ability to be flow by-passed with exception that built in heater choke shall remain in service.
5. Heater Choke valve shall be Long-nose (if possible) adjustable choke (manual handwheel).
6. Heater shell shall be insulated and protected by corrugated metal
7. Heater will have auxilliary coil for heating fuel and instrument natural gas

Page 3 of 3

You might also like