Professional Documents
Culture Documents
Product information
Application
safety device for gas pressure regulating stations
suitable for natural gas according to G260 other gases on request
Features
easy maintenance; easy replacement of internal parts without dismantling the valve from the line, few parts only
integrated pressure compensating valve
low pressure drop due to in-line flow
manual release as a standard feature
electric release and electric remote indication of valve position as special features
high response accuracy and short response time
max. flow rate should not exceed 80 m/sec
also available according to SIL-norm IEC 61508
technical data
max. operating pressure PSmax
sizes
connections
materials
main valve
switch device
measuring unit
internal parts
O-rings
closing spring
spring steel
response time ta
measuring unit)
Ex-protection
requirements).
CE-sign acc. to PED
pressure drop p
flowrate coefficient KG
Qn2
pu . KG2
sizes DN
KG-value in m3/h
25
1200
50
4790
80
12260
100
19160
150
43110
200
76650
250
119750
300
130400
adjustable ranges
control element
setpoint spring
K10a
K11a/1
K11a/2
K16
K17
overpressure release
wire-
range
min. differential
between rsponse
pressure and
service pressure
in mm
Wdso (bar)
pw (bar)
spec.
No. colour
1
bright red
3.2
0.08
dark red
3.6
white
4.75
underpressure release
range
min. differential
between
response
pressure and
service pressure
Wdsu (bar)
pw (bar)
spec.
minimum
redifferential
between over-/ sponse
underpressure precision
response points category
with spring no.:
4
5
6
AG*
... 0.25
0.05
0.09 0.13
10/5
0.2
...
0.5
0.10
0.15 0.18
5/2.5
0.4
...
1.5
0.25
0.30 0.34
5/2.5
white
1.2
0.01
...
0.04
0.03
black
1.4
0.035
...
0.12
0.06
bright red
3.2
0.4
...
0.8
0.1
10/5
dark red
3.6
0.6
...
1.6
0.2
10/5
white
4.75
1.5
...
4.5
0.3
5/2.5
light blue
1.1
0.06
...
0.15
0.05
20/5
black
1.4
0.12
...
0.40
0.08
red
2.25
0.35
...
1.00
0.10
white
4.75
2.25
2.5
...
8.0
0.5
20/5
5
5
1.0
0.8
10/5
red
black
4.5
...
0.2
2.5/1
grey
5.0
...
10
0.4
brown
6.3
...
20
0.8
red
7.0
10
...
40
1.2
...
2.2
0.4
20/5
grey
5.0
...
10
0.4
brown
6.3
...
20
0.8
red
7.0
10
...
40
1.2
K18
9.0
K19
9.0
20
...
90
1.5
1
20
...
90
1.5
*) The higher response category is valid for the first half, the lower response category is valid for the second half of the setting range.
operating lever
proximity sensor
manual release button
switching device
switching ring
closing springs
(flat spiral springs)
spring cover
hand lever for
reengagement
inlet pressure
outlet pressure
indication
measuring unit K 18
setpoint spring
vent/bleed line
valve latch
measuringline
valve flap
valve flap shaft
pressure transformer
inlet pressure
outlet pressure
atmosphere
The pressure to be monitored (service pressure) at the double diaphragm system has to be compared with
a setpoint value (response pressure setpoint) which is determined by the setpoint spring. When the upper
response pressure is reached, the overpressure at the control element K16 or K 18 causes the amplifying valve
to open. When the lower response pressure is reached, the underpressure at the control element K 17/K 19
equally causes the amplifying valve to open. In both cases gas flows from the monitoring system to the
pressure/force transformer. The pressure increase does move the piston into the direction of the switch
gear and causes that the valve flap shaft releases. The actuator springs cause the SAV to close.
control element (K16 for upper setting range)
setpoint
adjuster
valve flap shaft
setpoint spring
switching device
switching ring
vent/bleed line
retaining pipe
throttle
switching pin
SSV-measuring
line
double diaphragm
system
manual release
switching stem
pressure/ force transformer
amplifying valve
outlet pressure
atmosphere
7
operation with magnetic switch (electric release)
closing on current failure
The magnetic rod is brought into opening position by means of a stroke movement of the magnet against the force
of the closing spring. In operating condition the magnet is under current, should the current supply fail the closing
spring operates the switch stem.
closing on current supply
The stroke movement of the magnet is transmitted to the release mechanism of the switching device via a switch
stem. This causes the SAV to close.
setpoint
adjuster
pressure spring
magnetic switch
setpoint springs
switching stem
switching device
switching ring
retaining pipe
switching pin
outlet pressure
manual release
atmosphere
safety shut-off valve RMG 711 with control element K10a / K11a
measuring line E12 (M14 x 1,5)
safety shut-off valve RMG 711 with control element K16 / K17 / K18 / K19
dimensions in mm
size
A
PN
ANSI 300
ANSI 600
K 10a
K16
K18
RF
RTJ
K 10a
DN
25, 40
RF
RTJ
K 11a
K17
K19
25
170
170
180
180
260
295
415
160
110
K 11a
235
150
50
230
230
240
250
260
295
415
160
125
220
175
80
280
290
300
310
295
330
450
190
150
205
185
100
320
330
340
350
305
345
465
205
170
195
195
150
430
440
450
470
355
390
510
275
235
175
230
A
B
dimensions in mm
DN
25
50
80
100
150
flange
type
[mm]
[mm]
PN 25 and 40
18
1/2 x
70
ANSI 300 RF
18
5/8 x
80
22.5
5/8 x
90
xL
[Zoll x mm]
ANSI 600 RF
24
5/8 x
90
24
5/8 x
90
PN 25 and 40
23
5/8 x
85
ANSI 300 RF
23
5/8 x
90
29
5/8 x
100
ANSI 600 RF
33
5/8 x
110
34
5/8 x
110
PN 25 and 40
27
5/8 x
95
ANSI 300 RF
29
3/4 x
110
36
3/4 x
125
ANSI 600 RF
38.5
3/4 x
130
40
3/4 x
130
PN 25 and 40
27
3/4 x
105
ANSI 300 RF
32
3/4 x
115
38
3/4 x
130
ANSI 600 RF
45
7/8 x
150
46
7/8 x
150
PN 25 and 40
31
7/8 x
120
ANSI 300 RF
37
3/4 x
125
12
44
3/4 x
140
12
ANSI 600 RF
55
1 x
175
12
56
1 x
180
12
When using ductile screw bolts according to DIN 2510 a spacer between the two SSVs is required!
DN
DN
10
20
20
J
H
B
325
dimensions in mm
size
pressure stage
max
DN
max
max
J
approx.
PN 25
200
PN 40
725
650
750
420
230
350
242
310
380
650
775
420
230
350
312
370
390
173
730
PN 40
ANSI 300 RF/RJ
171
775
193
PN 25
300
PN 40
800
650
775
420
230
350
312
370
390
206
weights in kg
size
DN
weight in kg
25
50
80
100
150
200
250
300
20
26
56
85
200
430
500
700
connections
lines
measuring lines
vent lines
bleed lines
connection
E12
E12
E12
25
50
80
100
150
200
250
300
SSV-control element
Wdo [bar]
Wdu [bar]
control element
K10a
K11a/1
K11a/2
K16
K17
K18
K19
additional components
release by
manual release
HA
current supply
E1
loss of current
E2
remote indication
F
outdoortype
FA
special version
to be described in detail
So
FA
So
special version
HA
outdoor type
remote indication
K10a
additional components
DN
SSV-control element
size
size
RMG 711 - 50
type
example
11
ENGLAND
Osterholzstrasse 45
CANADA
Otto-Hahn-Strasse 5
USA
Julius-Pintsch-Ring 3
TURKEY
POLAND
ul. Sarnowska 2
63-900 Rawicz, Poland
Tel: +48 (0)65 5462401
Fax: +48 (0)65 5462408
RMG 711.00
2007-07