You are on page 1of 2

Flatpack2, Integrated

Power Supply System 150A 600A

Versatile and powerful solution for any application


The combination of cost-effective design, power density and
reliability makes the Flatpack2 a product family that truly stands
outs and provides unparalleled network availability. The versatility
of the Flatpack2 rectifier means that it can be used in a wide
variety of 48VDC and 24VDC applications across the globe.

The Flatpack2 Integrated is a compact power system


containing a Monitoring and Control Unit (Smartpack), LVD,
battery and load MCBs. It contains of a 4U distribution unit
and 1 to 4U of PR (power rack) which can house 4 Flatpack2
rectifier modules each. Switch mode technology with
resonant topology and high switching frequency is used to
minimize volume and weight and to obtain high reliability.
The system accepts large variations on the input voltage
(85-290 VAC) and draws sinusoidal current with a soft start
power-up.

Applications
Wireless, fiber and fixed line communication
Todays communications demand state of the art, cost
effective and compact DC power systems. Flatpack2
delivers an industry leading power density and superb
reliability at lowest lifetime cost
Broadband and network access
Increasing network speed demands flexible and expandable
DC power solutions. The Flatpack2 rectifiers are your key
building blocks for future needs.
Small and large
Due to the high power density, cost competitive design and
a highly flexible system communication interface, Flatpack2
rectifiers are used in system solutions from 5kW to 96kW.

Product Description
The Flatpack2 Integrated has been specifically designed to
meet the demand for higher density and more compact
power solutions. It is suitable for applications needing an
expandable, easily serviceable and reliable power supply,
fitting within a minimal space.

Key Features
Highest efficiency in minimum space
Resonant topology makes the module efficiency industry
leading and contributes to the rectifiers ultra compact
dimensions.
Digital controllers
Primary and secondary controls are digitalized, enabling
excellent monitoring and regulation characteristics. Thus,
the number of component has been reduced by 40% - for
highly reliable, long life, trouble free DC power systems.
Heat management
Front-to-back air flow with chassis-integrated heat sinks
gives the module the most suitable working environment
and no limitations in the scalability of the desired system
solution.
Unique connection
A true plug-and-play connection system: time-to-install and
cost-reducing solution.
Global approvals
Flatpack2 is CE marked, UL recognized and NEBS certified for
worldwide installation.

See reverse side for specifications

Flatpack2 PS System 150A 600A, Integrated


Additional Technical Specifications
AC Input

DC Distribution Options

Voltage

1 phase 230 VAC


3 phase 230 VAC ( )
3 phase 400 VAC+N ( Y )

Frequency

45 to 66Hz

Maximum Current

See Flatpack2 48VDC datasheet

Input Protection

o
o
o
o

Soft start
Surge protection (varistors)
Internal fuses (L & N)
Disconnect above 300 VAC

Monitoring

Load breakers and


fuses

o 18 x (2-63A)
o 9 x (2-63A) + 6 x (80-125A)

No. of Battery fuses

o 6 (max. 100A each)


o 3 (max. 200A each)
o 2 (max. 250A each)

Programmable
LVD

o 1 LVBD (150, 300, 500 or 600A)


o 1 LVLD (150, 300, 500 or 600A)

Connections

Monitoring Unit

See Smartpack datasheet

Battery connections

Battery cable, M8 bolts

Local Operation

Menu driven software via


keypads and LCD or PC (PowerSuite)

Load MCB
connections

Negative distribution directly from


CBs. Common positive bus bars

Remote Operation

PowerSuite via modem or Monitoring


via WebPower (WEB Interface and
SNMP protocol)

Alarm connections

Plug-in wire connectors front or


rear access

Alarm Relays

6 relays

Visual Indications

o
o
o
o

Other Specifications

Green LED System ON


Yellow LED Minor alarm(s)
Red LED Major alarm(s)
LCD system status

Digital Inputs

6 (for monitoring of external


equipment)

Current
Measurements

o Battery current
o Rectifier current

Alarms

o
o
o
o
o
o
o
o
o
o

Load fuse alarm


Battery fuse alarm
LVD operated
Low output voltage alarms
(2 individual alarm levels)
High output voltage alarms
(2 individual alarm levels)
Battery capacity
Temperature alarm
Symmetry alarm

Isolation
Operating
temp.

-40 to +60C (-40 to +140F)

Storage
temp.

-40 to +85C (-40 to +185F)

Dimensions

482 x 380 x 267mm (6U) (wxdxh) (19 x


14.9 x 10.5) recommended cabinet
depth is min 400 mm (15.7)

Weight

Approx. 5kg (11lbs) excl. rectifiers

Applicable Standards
Electrical safety

IEC/UL 60950-1
CSA 22.2

EMC

ETSI EN 300 386 V.1.3.2


(telecommunication network)
EN 61000-6-3
(emission, light industry)
EN 61000-6-2
(immunity, industry)

Environment

ETSI EN 300 019-2


o Class 1.2, 2.3, 3.2
ETSI EN 300 132-2

DC Output
Voltage

48 VDC

Current

o
o
o
o

5U
6U
7U
8U

Max. 150A
Max. 300A
Max. 450A
Max. 600A

o 3.0 KVAC input and output


o 1.5 KVAC input earth
o 0.5 KVDC output earth

Ordering Information

Part no.

241115.100
241115.105
241115.110
241119.100
CTO20405.nnn
CTO20406.nnn
CTO20407.nnn
CTO20408.nnn
CTO30405.xxx
CTO30406.xxx

Description

(Sales configured systems, CTO)

Flatpack2 Rectifier, 48V 2kW


(rectifier option I)
Flatpack2 Rectifier, 48V 2kW HE
(rectifier option II) High Efficiency
Flatpack2 Rectifier, 48V 2kW BF
(rectifier option III) Back-to-Front Air flow
Flatpack2 Rectifier, 48V 3kW
(rectifier option IV)
Flatpack2, 4U Integrated 8kW
(with rectifier options I, II and III)
Flatpack2, 4U Integrated 16kW
(with rectifier options I, II and III)
Flatpack2, 4U Integrated 24kW
(with rectifier options I, II and III)
Flatpack2, 4U Integrated 32kW
(with rectifier options I, II and III)
Flatpack2, 4U Integrated 12kW
(with rectifier options IV)
Flatpack2, 4U Integrated 24kW
(with rectifier options IV)

Specifications are subject to change without notice

.
Headquarters:
Eltek Valere
1303 E. Arapaho Rd, Richardson, TX. 75081, USA
Phone: +1 (469) 330-9100 Fax: +1 (469) 330-9101

Eltek Valere
Grterudv. 8, PB 2340 Strms, 3003 Drammen, Norway
Phone: +47 32 20 32 00 Fax: +47 32 20 32 10

200000.DS3 5v0

You might also like