You are on page 1of 28

OTA101102 OptiX Metro 100 Hardware

Description

ISSUE 1.0

Confidential Information of Huawei.


No Spreading without Permission.

1
Objectives

Upon completion of this course, you


will be able to:
‰ Describe the network applications of the
OptiX Metro 100
‰Explain the system structure and features of
the OptiX Metro 100
‰Outline the system protection modes of the
OptiX Metro 100
‰ State the main functions of the cards in the
OptiX Metro 100

Internal Use 2
Chapter 1 Network Application and System structure

Chapter 2 Sub-rack

Chapter 3 Equipment Cards

Chapter 4 Equipment Level Protection

Internal Use 3
Network Application
OptiX OSN 9500
OptiX OSN 7500 OptiX OSN 7500

Core

OptiX OSN 3500 OptiX OSN 3500

Convergence
layer

OptiX OSN 1500 OptiX OSN 1500

Access layer

OptiX Metro 1000 OptiX Metro 1000


Network
OptiX Metro 100 OptiX Metro 100 terminal unit

Switching /
Ethernet
Base Station

Position of the OptiX Metro 100 in transport network

Internal Use 4
System Structure

E1 service
STM-1 optical VC-4 VC-4
and Ethernet
signal
service
Line 4x4
Tributary
unit VC-4 unit
Cross-
STM-1 optical connect
signal E1 service
unit and Ethernet
service

External
power Power Clock SCC
unit unit
supply unit

Internal Use 5
System Features

‰ High Integration Design


‰ Low Power Consumption :15W
‰ Easy and Flexible Installation
In the 19-inch/ETSI 300 mm /ETSI 600 mm cabinet.
On the wall.
Outdoors.
On the desktop.
‰ Multi-service Access Capability
8 x E1 services
4 x 10M/100M services
1/2 x STM-1 services
‰ Multiple Management Modes
OptiX iManager T2000 network management system
Web-LCT local management system
LCD control panel

Internal Use 6
Chapter 1 Network Application and System Features

Chapter 2 Sub-rack

Chapter 3 Equipment Cards

Chapter 4 Equipment Level Protection

Internal Use 7
Sub-rack

Appearance of Metro 100

OptiX Metro 100 (–48 V/–60 V DC input + 1 STM-1 + E1)

200mm

42mm

436mm

OptiX Metro 100 (–48 V/–60 V DC input + 2 STM-1 + E1 + 10M/100M)

Internal Use 8
Sub-rack

Indicators
NM-LAN

LCD Operation Button


ESD

Power Supply
Optical interface
-48V/-60V/24V DC
110/220V AC Audible alarm Cut
RST 8×E1

Lamp Test
Power Switch Alarm input/output
10M/100M Ethernet interface

Internal Use 9
Sub-rack
Indicators
Indicator Status Description

Flash 5 times every second. Loading the NE software.


RUN (running indicator) Flash once every second. The NE software is lost, waiting to be loaded.
Flash once every two seconds Normal operation.
MAJ (major alarm indicator) On A critical or major alarm occurs.
MIN (minor alarm indicator) On A minor alarm occurs.
ACO (alarm cut indicator) On The equipment has cut the alarm sound.
The optical interface cannot receive the optical
LOS (loss of line signal indicator) On
signals or the optical power is too low.
Off E1 port is not used.
Constantly on, red E1_LOS alarm occurs to E1 path.

E1 1–8 (multicolor indicator Flashing, red Major alarms (not E1-LOS) occur to E1 path.
alerting loss of E1 signal) Constantly on, orange Minor alarm occurs to E1 path.
Flashing, orange BIPEXC alarm occurs to E1 path.
Constantly on, green E1 path is in use and no alarm occurs.
On The link connection is normal.
LNK (green)
Indicator of Off The link is not connected or broken.
RJ-45 Flash or on Data are being transmitted.
ACT (yellow)
Off No data is being transmitted.

Internal Use 10
Chapter 1 Network Application and System Features

Chapter 2 Sub-rack

Chapter 3 Equipment Cards

Chapter 4 Equipment Level Protection

Internal Use 11
Equipment Cards

zMetro 100 is a integrated system, it can be classified as

Ethernet Unit
SDH Unit
PDH Unit

Internal Use 12
PDH Unit

Send to SCC

Collect Alarm and


Interface Type: performance
75ohm or 120ohm
DDF PDH
VC4
8×E1
Unit
Provides inloop/outloop

Cautions

The impedance of the interface is defined before delivery and


cannot be set on site

Internal Use 13
PDH Unit
Alarm List

Alarm name Alarm Description Level


HARD_BAD Hardware fails Critical
BD_STATUS Board not in position alarm Major
TU_AIS TU alarm indication Major
TU_LOP TU loss of pointer Major
T_ALOS 2M interface loss of analog signal Major
UP_E1AIS 2M signal alarm indication Major
HP_LOM Higher order path loss of multiframe Major
BIP_EXC BIP excessive errors Minor
BIP_SD BIP signal degraded Minor
DN_E1AIS 2M down signal alarm indication Minor
LOOP_ALM Loop alarm Minor
LP_RDI Lower order path remote defect indication Minor
LP_REI Lower order path remote error indication Minor

Internal Use 14
Ethernet Unit

duplex and auto-negotiation

N×VC12

Ethernet
GFP

10M/100M
Unit 1×VC4 VC4

N×VC3

‰Supports link capacity adjustment scheme (LCAS).

‰ProvidesEthernet port inloop function.


‰Supports the JUMBO frame.

‰Sends test frames to test the make/break status of services.

Internal Use 15
Ethernet Unit
Alarm List

Alarm name Alarm Description Level


HARD_BAD Hardware fails Critical
ETH_LOS Ethernet receive loss of input signal Critical
VC_DELAY_TL VC delay too long Critical
FCS_ERR FCS error Critical
BD_STATUS Board not in position alarm Major
TU_AIS_VC3(VC12 ) TU alarm indication Major
TU_LOP_VC3(VC12) TU loss of pointer Major
B3_EXC_VC3 (VC12 ) B3 excessive bit error indication Major
LOOP_ALM Loop alarm Minor
LP_RDI_VC3(VC12) Lower order path remote defect indication Minor
LCAS_BAND_DECREASED LCAS bandwidth protect alarm Minor

Internal Use 16
SDH Unit

Optical Module Type

Line unit Processing capability Optical module type Connector type

SL1 1 x STM-1 Dual-fiber receiving /transmitting S-1.1 SC

SD1 2 x STM-1 Dual-fiber receiving /transmitting S1.1 SC

SFP 2 x STM-1 Dual-fiber receiving /transmitting S1.1 LC

SB1 1 x STM-1 Single-fiber receiving /transmitting S1.1 SC

SB2 2 x STM-1 Single-fiber receiving /transmitting S1.1 SC

Internal Use 17
SDH Unit

Send to SCC

Interface Type:
Collect Alarm and
SC or LC
performance

SDH
STM-1 VC4

Unit
Provides inloop/outloop for
VC4,Electrical/optical interface

‰Supports automatic laser shutdown (ALS) function.

‰Can query the optical module information and laser performance


through the software.

Internal Use 18
SDH Unit
Alarm List
Alarm name Alarm Description Level
R_LOF Receive loss of frame Critical
R_LOS Receive loss of signal Critical
HARD_BAD Hardware fails Critical
MS_AIS Multiplex section alarm indication Major
AU_AIS AU alarm indication signal Major
B2_EXC Multiplex section B2 excessive bit error indication Major
B3_EXC High order path B3 excessive bit error indication Major
BD_STATUS Board not in position alarm Major
B1_EXC Regenerator section B1 excessive bit error indication Minor
MS_RDI Multiplex section remote defect indication Minor
HP_RDI Higher order path remote defect indication Minor
HP_REI Higher order path remote error indication Minor
HP_TIM Higher order path tracking identifier mismatch Minor
LOOP_ALM Loop alarm Minor

Internal Use 19
Clock Unit

Line clock source ( 2 )


PDH Unit

Clock
System
E1 Clock source ( 1 ) SDH Unit
Clock
Unit
Ethernet Unit

Internal source ( 1 )

Notes

When the OptiX Metro 100 is configured as a (TM), and clock unit is STGT, the clock
supports the locked mode and free-run mode.The others can supports locked mode,
holdover mode and free-run mode.

Internal Use 20
Clock Unit
Alarm List

Alarm name Alarm Description Level


HARD_BAD Hardware fails Critical
BD_STATUS Board not in position alarm Major
LTI Loss of synchronous source Major
S1_SYN_CHANGE Clock reference source change in S1_mode Major

SYNC_C_LOS Synchronous source level loss Major


SYN_BAD Synchronous source deteriorated Minor

Internal Use 21
Cross-Connect Unit

Functions
‰ Provides the service grooming capability of the add/drop
multiplexer (ADM).

‰ Supports 4 x 4 VC4s full cross-connect, 12 x 12 VC3s full


cross-connect and 252 x 252 VC12s full cross-connect.

Alarm
BD_STATUS Major alarm

Internal Use 22
SCC Unit

SDH Unit
Alarm Alarm
PDH Unit SCC and
Ethernet Unit Performance

Clock unit Unit NM


performance
Cross-connect Unit

DCC

Metro 100

Internal Use 23
SCC Unit

Alarm List

Alarm name Alarm Description Level


DBMS_ERR Database error Critical
NESTATE_INSTALL NE is installing Critical
NO_BD_SOFT No board software Critical
HARD_BAD Hardware fails Critical
VOLT_LOS Voltage loss Major
SECU_ALM Temperature over threshold Major
FPGA_ABN FPGA abnormal Major
TEMP_ALARM Temperature over threshold Minor

Internal Use 24
Chapter 1 Network Application and System Features

Chapter 2 Cabinet and Sub-rack

Chapter 3 Equipment Cards

Chapter 4 Equipment Level Protection

Internal Use 25
Equipment Level Protection

Power input unit 1+1 hot


backup

Failed
Input PWR1 Input PWR2

Internal Use 26
Summary

Network Application and System Structure


Summary Cabinet and Sub-rack

Equipment Cards

Equipment Level Protection

Internal Use 27
Confidential Information of Huawei. No Spreading without Permission.

You might also like