You are on page 1of 8

measurIT technologies

pH sensors: Patented Axial Ion Path Reference Cell

2 to 6 times the total KCl elec trolyte of competing sensors Max Temperature 1500C

Axial Ion Pathways prevent poisoning Max pressure 170 bar


Axial Ion Path sealing rings prevent internal plugging and insure against internal leaks Sulfide poison resistant
Glass breakage and leak pathways during manuf acture eliminated Oxidizer resistant
Complete filling of reference body allows extreme temperature and pressure tolerance
Non-polymerized electrolyte insures compatibility with wide range of chemistries
Large-area, liquid junction slows the buildup of coatings & reduces sensor “drift”
Long life in both low and high pH applications

Sensor Body
Glass electrode

Cutaway
Wood Spool

Body to Spool Isolation


Spool to Measuring disk with 10 Axial Ion
Electrode Isolation Disk
Paths for Effective
Axial Ion Path Sealing Rings Plug-free Communication

Individually configured to suit the process

546/556 In-line & Submersible

551/561 Quick Change

547/557 Cartridge

547/557
546/556 Hi-Pressure Ball Valve
Ball Valve Insertion Assembly
Insertion Assembly

MeasurIT Technologies Ltd.


Craan, Craanford, email: info@measurIT.com Phone: +353 (0) 53 942 8962
Gorey, Co. Wexford, Ireland www.measurIT.com Fax: +353 (0) 53 942 8963
measurIT technologies

547/557 sensor cartridges are assembled


in a reusable Titanium sheath, Hi-Pressure
body, or Hi-Purity flow cell.

The ball-valve insertion assembly is the most popular


application for the 547/557 cartridge. This system allows
maintenance and replacement of the sensor without shutting off the
process line or draining the tank. Operationally rated to 100 psig
/ 6 bar. Insertion depths, materi als, and cleaning systems
are customer selectable to insure the best measurement.

Pressure Monster sensor body allows certification up


to 2,500 psig / 170 bar, even while tolerating elevated
temperatures.

When matched with Hi-Purity flow cell, a stable pH


measurement down to 0.5 micro Siemens is achieved.
This system can be provided as a separate unit, or as part
of an assembled Hi-Purity measurement panel.

www.measurIT.com
measurIT technologies

546 / 556 Threaded In-Line,


Submersible or Hi-Pressure Insertion

Features:
Chemically resistant CPVC, KYNAR, Polypropylene or PEEK body,
Rugged, quick-change, quick-clean,
Optional installation methods allows standard ization of entire plant with a minimum of
sensor part numbers,
546/556 sensors and assembly parts are interchangeable with ABB TBI-Bailey Models
TB556 and TBX556,
pH sensors utilize patented Axial Ion Path reference cell.

Sensor & Transmitter types supported:


pH, ORP, ISE, 4-electrode Conductivity, DO
Compatible with most industrial transmitters and analyzers

Wetted materials:
KYNAR, CPVC, PEEK, Polypropylene. Gr.2 Titanium, 316 Stainless Steel, porous TEFLON,
VITON, EPDM, Kalrez, Nickel, Wood, & Glass.

Maximum Pressure & Temperature Ratings


Max temperature: 150 0 C (PEEK), 140 0 C (Kynar), 100 0 C (CPVC and Polypropylene)
Max pressure: 150 psig / 10 bar for standard systems
Max pressure: 300 psig / 20 bar (Hi-Pressure Insertion system)
See temperature and pressure charts for complete ratings

www.measurIT.com
measurIT technologies

547 / 557 Insertion - Retraction,


Threaded In-line, Submersible,
Hi-Pressure, Hi-Purity

Features:
Chemically resistant CPVC, KY NAR, Polypropylene or PEEK body,
Rugged, quick-change, quick-clean,
Optional installation methods allows standardization of entire plant with a minimum of
sensor part numbers,
547/557 sensors and assembly parts are interchangeable with ABB TBI-Bailey Models
TB557 and TBX557,
pH sensors utilize patented Axial Ion Path reference cell.

Sensor & Transmitter types supported:


pH, ORP, ISE, 4-electrode Conductivity, DO
Compatible with most industrial transmitters and analyzers

Wetted materials:
KYNAR, CPVC, PEEK, Polypropylene. Gr.2 Titanium, 316 Stainless Steel, porous TEFLON,
VITON, EPDM, Kalrez, Nickel, Wood, & Glass.

Maximum Pressure & Temperature Ratings


Max temperature: 150 0 C (PEEK), 140 0 C (Kynar), 100 0 C (CPVC and Polypropylene)
Max pressure: 150 psig / 10 bar for standard systems
(may be operationally limited to 100 psig / 6 bar depending upon system)
Max pressure: 2,500 psig / 170 bar (Pressure Monster system)
See temperature and pressure charts for complete ratings

www.measurIT.com
measurIT technologies

Quick-change
In-line or Submersible

Features:
Chemically resistant CPVC, KY NAR or Polypropylene body,
Rugged, quick-change, quick-clean,
Optional installation methods allows standardization of entire plant with a minimum of
sensor part numbers. Ideal for sample lines and valved side-streams,
551/561 sensors and assembly parts are interchangeable with ABB TBI-Bailey Models
TB(X)551 and TB(X)561,
pH sensors utilize patented Axial Ion Path reference cell.

Sensor & Transmitter types supported:


pH, ORP, ISE, 4-electrode Conductivity, DO
Compatible with most industrial transmitters and analyzers

Wetted materials:
KYNAR, CPVC, Polypropylene. Gr.2 Titanium, 316 Stainless Steel, porous TEFLON,
VITON, EPDM, Kalrez, Nickel, Wood, & Glass.

Maximum Pressure & Temperature Ratings


Max temperature: 140 0 C (Kynar), 100 0 C (CPVC and Polypropylene)
Max pressure: 150 psig / 10 bar for standard systems
Max pressure: 300 psig / 20 bar (Hi-Pressure Insertion system)
See temperature and pressure charts for complete ratings

www.measurIT.com
measurIT technologies

General purpose
In-line or Submersible pH Sensors
BAT-1 Industrial pH Sensor with PT100 Temperature Comp Unit
BAT-2 Industrial pH Sensor with Balco 3.01k Temperature Comp Unit

Design:
Longer lasting performance and minimal maintenance. The general Purpose CPVC sensor can
be used in either threaded insertion or submerged applications, using a 3/4’’ MNPT thread at both
the top and bottom of the sensor body.

Extreme Duty AIP Reference (Patent Pending):


A large multi-segment solid-state reference permanently infused with potassium chloride (KCl),
separated by a series of Axial Ion Path Sealing Rings, out performs the competition in longevity
and resistance to poisoning.

Features:
CPVC body, AIP reference with VITON sealing rings, general purpose pH glass measuring electrode,
Flush porous TEFLON liquid junction, dual notch tip protection, thermocompensation - 3k ohm Balco
or PT100 RTD, and a flexible hi-temp, Lo-loss TPE jacketed cable. BAT-1 with PT100 utilizes all
tinned leads, the BAT-2 provides a BNC connection for the measuring electrode and reference and
tinned leads for the temperature compensation unit.

Wetted materials:
CPVC, Wood, porous TEFLON, VITON and Glass.

Maximum Pressure, pH & Temperature Ratings


1-13 pH
Max temperature: 0-100 0 C
Max pressure: 150 psig / 10 bar
See temperature and pressure charts for complete ratings

www.measurIT.com
measurIT technologies

The ‘Pressure Monster’


Extreme - Pressure pH Sensor

Features:
Chemically resistant CPVC, KYNAR, Polypropylene or PEEK sensor cartridge,
Armored Hi-pressure body made from SS316, Titanum or Hasteloy C,
Can be equipped to provide triple redundancy against toxic gas escape,
pH sensors utilize patented Axial Ion Path reference cell.

Sensor & Transmitter types supported:


pH, ORP, 4-electrode Conductivity,
Compatible with most industrial transmitters and analyzers

Wetted materials:
KYNAR, CPVC, PEEK, Polypropylene. Gr.2 Titanium, 316 Stainless Steel, porous TEFLON,
VITON, EPDM, Kalrez, Nickel, Wood, & Glass.

Maximum Pressure & Temperature Ratings


Max temperature: 150 0 C (PEEK), 140 0 C (Kynar), 100 0 C (CPVC and Polypropylene)
Max pressure: 2,500 psig / 170 bar
See temperature and pressure charts for complete ratings

www.measurIT.com
measurIT technologies

Electrode and Tip Protection Options

Hemi
Flat
Dome

Flush Tip
Best resistance to fouling by particulates.
Hemi glass provides greatest strength against high
pressure and temperatures, best response time,
greater signal strength, and resistance to caustic
and HF processes.
Flat glass is less exposed to impact damage
or abrasive flows.

Dual Notched Tip


Hemi glass provides best overall measurement and durability,
with added protection of notched flange.
Flat glass dual notch improves impact protection over flush tip
design, and is slightly easier to clean.
Notches can be oriented 70° to flow causing process liquid to
swirl around hemi-tip, reducing abrasion and particulate
build-up.

Recessed Tip
Provides maximum tip protection against impact
damage and abrasive flows. Most suitable where
there is little risk of particulate or fibrous build-up.

MeasurIT Technologies Ltd.


Craan, Craanford, email: info@measurIT.com Phone: +353 (0) 53 942 8962
Gorey, Co. Wexford, Ireland www.measurIT.com Fax: +353 (0) 53 942 8963

You might also like