You are on page 1of 3

TOA Electronics Southern Africa (Pty) Ltd

QUOTATION CONFIRMATION
Quote date:
project start:
Quote no:
created by:
sales rep:
contact:
phone:
cell:
fax:
email:
VAT no:

Johannesburg - Gauteng - RSA


+27 11 608 1477

COMPANY:
PROJECT NAME:

0
njacobs@toasa.co.za
0

MH Engineering Plc (Consulting Engineers &


Architects)
Saudi German Hospital - Ethiopia
Hi Daniel, Herewith pricing based on suggested recommended retail pricing ex
works Germany warehouse. Have a look and let us know what you think. (We
based the design on the drawings received, I will also send you pricing on our
VM-3000 system to compare). Best regards Nastassia Jacobs

NOTES:
STATUS: Ex Germany

placed

invoice to:

deliver to:

6th Floor , Alem building #2


Bole Road
Addis Ababa, Ethiopia
0

6th Floor , Alem building #2


Bole Road
Addis Ababa, Ethiopia
0

CODE

2016-06-02
2016-06-02
55807
Tiffany Hepburn
Tiffany Hepburn
Daniel Mekonnen
251936647752

DESCRIPTION

UNIT

QTY

REF

NETT PRICE

Speakers
PC-1869EN

Ceiling Speaker - Certified EN54-24

$ 42.08 379

$ 15 946.43

PC-658R-F00

6 Watt Clip-in Ceiling Speaker 6inch - White

$ 20.08 1

$ 20.08

$ 2 343.02 1

$ 2 343.02

$ 111.65 3

$ 334.96

$ 41.25 2

$ 82.51

$ 722.78 1

$ 722.78

$ 1 166.61 1

$ 1 166.61

Head End Equipment


VX-2000

Venas - Integrated Voice Evacuation System SANS60849/EN60849/IEC60849 compliant

VX-200XR

Remote microphone input module

U-03R

Auxiliary Input Module

EV-200M

Voice Announcement Board With Memory Card

RM-200XF

Firemans Microphone for VX-Series

RM-200XS

Remote Microphone for VX-Series (Successor of RM200X)

$ 742.19 3

$ 2 226.58

RM-210S

Remote Microphone Extension (Successor of RM-210)


Fully Compatible with all RM`s

$ 302.09 8

$ 2 416.71

VX-2000SF

Surveillance frame.

$ 1 450.46 3

$ 4 351.38

VP-2241

1 Channel power amplifier @ 240W RMS per channel

$ 766.32 5

$ 3 831.60

VP-2064

4 channel power amplifier @ 60W RMS per channel

$ 781.19 7

$ 5 468.32

VP-200VX

Power amplifier input module (also for use with VM-3000)

VX-2000PF

Power supply frame

$ 176.72 3

$ 530.15

VX-200PSER

Dual power supply module

$ 441.79 5

$ 2 208.94

$ 28.05 33

$ 925.54

CODE

DESCRIPTION

UNIT

VX-2000DSER

Emergency Power supply unit

QTY

REF

NETT PRICE

$ 954.25 3

$ 2 862.75

Total Excl. Tax:

$ 45 438.34

TOTAL:

$ 45 438.34

TERMS AND CONDITIONS EX GERMANY


1. Prices are NETT ex TOA Electronics Germany bonded warehouse.
2. All export orders must be paid for in full and clear into our bank account and on receipt of forwarders/shippers details before orders will
be placed with the Germany warehouse.
3. Stock availability must be confirmed by the client when placing the order. Stock will only be placed on reserved list once full payment
has been received for the order.
4. Stock availability subject to change without prior notice.
5. All taxes and duties are for the clients account.
6. Guarantee: One year on all equipment but does not cover damage due to misuse, tampering and wear and tear.
7. Prices are fixed in USD for 60 days from date of quotation.
8. All shipping, clearing and insurance costs are for the importers account. The importer is to arrange collection and shipping of the order.
9. The forwarding company collecting on your behalf in Germany must be able to provide a T1 document. (The T1 document applies for
goods produced outside the European Union [EU], but are actually physically present with the EU borders and have not yet been cleared
or re-exported. These goods are not part of free trade. A T1 document is obligatory for shipping these not [yet] cleared goods within the
EU.)
10. Pre-Inspection: this is for the clients account if applicable for the country of import. (For more information, contact your Bureau of
Standards or relevant government body.)
11. All our products are packaged export ready. Any additional packaging required must be by instruction from the client to their
shipper/forwarder.
12. South African Law and South African Forum for any litigation or arbitration.
13. The GENERAL TERMS and CONDITIONS OF SALE can be produced on request or downloaded here. (www.toasa.co.za download forms)

CODE

DESCRIPTION

PC-1869EN

Ceiling Speaker - Certified EN54-24

PC-658R-F00

6 Watt Clip-in Ceiling Speaker 6inch - White

VX-2000

Venas - Integrated Voice Evacuation System SANS60849/EN60849/IEC60849 compliant


TOAs VX-2000 series is a broadcast and public address system that satisfies all the requirements for general
purpose and emergency broadcasts for a wide range of environments and configured for simple as well as
complex installations

Remote microphone input module


VX-200XR

Remote microphone input module for RM200X and RM200XF. Max 8 modules of combined VX200XI,
VX200XR and 900 series

U-03R

Auxiliary Input Module

EV-200M

Voice Announcement Board With Memory Card

Unbalanced line input module with high/low cut filters. Dual RCA with passive summing.

Voice storge unit with memory card for the use with VM-2000 amplifiers.

Firemans Microphone for VX-Series


RM-200XF

Firemans microphone with unidirectional dynamic fist type microphone with fault detection. Function keys - 15
(Extra 105 with RM210) Max 4

Remote Microphone for VX-Series (Successor of RM-200X)


RM-200XS

RM-210S

Remote microphone with unidirectional electrec goose-neck mic. Function keys 15 (extra 105 with RM210)
Max 8 incl. RM200XF

Remote Microphone Extension (Successor of RM-210) Fully Compatible


with all RM`s
The Extension unit allows additional 10 zones (per unit) to be added to the RM-200.

Surveillance frame.
VX-2000SF

VP-2241

Surveillance frame. Min 1 - Max 5 per system. Each frame provides 4 EB I/P, 4 EB O/P at 0dBV via RJ45
connectors. 10 module slots. Usable modules VX200SZ, VX200SP, VX200SI, VX200SO.

1 Channel power amplifier @ 240W RMS per channel


1 Channel power amplifier @ 240W RMS per channel. 2U

4 channel power amplifier @ 60W RMS per channel


VP-2064

VP-200VX

4 channel power amplifier @ 60W RMS per channel. Requires VP200VX input module per active/standby
channel. 2U

Power amplifier input module (also for use with VM-3000)


Power amplifier input module. 1 required per amplifier channel. RJ45 connector

Power supply frame


VX-2000PF

Power supply frame. Min 1 - Max 10 per system. Will accommodate 1 - 3 dual power supply modules
VX200PS. 3U

VX-200PSER

Dual power supply module

VX-2000DSER

Emergency Power supply unit

Dual power supply module. 3 units mountable per VX2000PF

Emergency Power supply unit. min 1 - max 10 per system. SLA charge current 5A max.