You are on page 1of 56

POWERING THE

WORKSTATION

UNDERFLOOR
TO WORKSTATION
POWER AND DATA
DISTRIBUTION
SYSTEMS

THE GLOBAL SPECIALIST


IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Global
strength
built on local
knowledge
Legrand is the global specialist in electrical and digital
building infrastructures. Innovation is the driving force
behind its development. With an increasing investment
in research and development (circa 5% of sales) and
more than 4,000 active patents, the Legrand Group
is focused on maintaining a high rate of new product
launches that present innovative solutions to the market.

LEGRANDS POWER DISTRIBUTION


BUSINESS UNIT
From Zucchini transformers, through high power
distribution and rising main busbar to Electrak
powertrack, desk modules and lighting control,
Legrands power distribution business unit provides
market leading solutions to the increasing demands
of todays buildings.

SUSTAINABLE DEVELOPMENT
From design through to manufacturing,
the Legrand Group selects materials and
processes that respect people and the
environment.
Eficient and environmentally aware product design
Product functions that help to avoid energy waste
Management of manufacturing and logistics sites
Integration of environmental concerns and
ISO 14001 procedures at the Groups global sites*

* 84% of sites are ISO 14001:2004 accredited including all UK sites.

XX

CONTENTS
POWERTRACK
Overview
Ordering information
Technical information

6
8
17

FLOOR BOXES
Overview
Ordering information
Technical information

22
24
29

GROMMETS
Overview
Ordering information
Technical information

30
32
33

INTERSOC-R
Overview
Ordering information
Technical information

34
38
42

INTERSOC ON-DESK
Overview
Ordering information
Technical information

UNDERFLOOR TO WORKSTATION
WWW.LEGRAND.CO.UK/ELECTRAK

46
50
52

SYSTEM GUIDE

Electrak
...
the specialist in power distribution
throughout the workplace
Electrak, a brand of the Legrand Group in the UK, is a leading name
in power distribution and lighting control solutions. Electrak busbar
systems, loor boxes, grommets, desk modules and lighting control
ranges are installed in high speciication ofices around the world.

POWERING THE WORKSTATION


UNDERFLOOR POWER
Electraks power track system is perfect for supplying underfloor power in cavity
floor installations. With minimal parts, push-fit assembly and a complementary
range of floor boxes, this flexible, easy to install system can be reconfigured as
office layouts evolve.

POWER TRACK
See page 6

CAVITY FLOOR BOXES


See page 22

WORKSTATION POWER
Electraks access grommets provide the gateway for power to feed from the
underfloor power track network to the workstation, where all desk power
requirements are met with our new range of desk modules, Intersoc-R and
Intersoc on-desk.

GROMMETS
See page 30

INTERSOC-R
See page 34

INTERSOC ON-DESK
See page 46

FULLY ADDRESSABLE LIGHTING CONTROL


Designed to work in harmony with Electraks buscom trunking, Lightraks
lighting control system offers high end sophistication with unbeatable
flexibility and speed of installation.
Find out more at www.legrand.co.uk/electrak

BUSCOM
power and data backbone

LIGHTRAK
lighting control system

UNDERFLOOR TO WORKSTATION
WWW.LEGRAND.CO.UK/ELECTRAK

SYSTEM GUIDE

Electrak
...
UK manufacturing. Global recognition

OVER 30 YEARS OF EXPERIENCE

QUALITY ASSURED UK MANUFACTURING

Legrands cost-effective Electrak systems have


been designed and manufactured to distribute
power and data reliably and safely throughout
the workplace. The original underloor busbar
system, invented by Electrak in the 1980s, sets the
benchmark for lexible power distribution.

With its Electrak ranges manufactured from its


UK manufacturing base situated in the North
East of England, Legrand adapts to the changing
demands of projects by providing a rapid production
process whilst ensuring quality meets the highest
standards.

INDUSTRY EXPERTS
As part of its ongoing commitment to research
and development, Legrand continually evolves its
product ranges to ensure it develops the best and
most innovative solutions available on the market.
Legrand takes pride in its enviable reputation for
market leading customer service, industry
knowledge and product expertise.

Trusted throughout the UK and across the world

UNITED KINGDOM

MIDDLE EAST & INDIA

ASIA PACIFIC

Morgan Stanley, Canary Wharf


Media City, Manchester
JP Morgan, Canary Wharf
RBS, Edinburgh
Bridgewater Place, Leeds
Network Rail, Nationwide
Swiss Re, City of London
Amazon, Swansea
Heathrow Airport, London
Fort Dunlop, Birmingham
Royal Bank of Canada,
City of London
Snow Hill, Birmingham
Barclays Capital, Canary Wharf
Temple Back, Bristol
Standard Chartered Bank,
City of London
London Underground
BBC, White City
Mann Island, Liverpool

ADMA-OPCO HQ, Dubai


Internet City, Dubai
Burjuman Centre, Dubai
ADIC/Al Bahr Towers, Abu Dhabi
Al Dar HQ, Abu Dhabi
Central Bank of Kuwait
Ministry of Education, Kuwait
PIFFS Aridya, Kuwait
PAAET, Kuwait
Qatar News Agency
Barclays, Chennai, India
Barclays, Pune, India
Barclays, Andheri, India
Barclays, Mumbai, India
RBS, Delhi, India
Fidelity, Delhi, India

Credit Suisse, ICC I, Hong Kong


Deutsche Bank, ICC I, Hong Kong
Barclays Capital, Cheung
Kong Centre
Customs Headquarters,
North Point, Hong Kong
Standard Chartered Bank,
IFC II, Hong Kong
Citi Bank Tower, Hong Kong
Macquarie Bank, IFC I, Hong Kong
UBS Bank, IFC II, Hong Kong
JP Morgan, Hong Kong
Standard Chartered Bank, Marina
Bay, Singapore
Barclays Capital, Marina Bay, Singapore
Nomura Bank, Marina Bay, Singapore
Credit Suisse, Serangoon Road,
Singapore
ABN Amro, One Rafles Quay, Singapore
RBS, One George Street, Singapore
Barclays Capital, Shanghai
Standard Chartered Bank, Shanghai
UBS Bank, Shanghai

UNDERFLOOR TO WORKSTATION
WWW.LEGRAND.CO.UK/ELECTRAK

SYSTEM GUIDE

Powertrack...
adaptable, reliable
underfloor power

Integral track connector plugs into feed unit

Lengths simply push-fit together

Integral fixing brackets for rapid installation

Tap-offs plug in to shuttered socket outlets


and lock on to track body

THE INDUSTRY STANDARD IN UNDERFLOOR POWER


Electrak powertrack / underloor busbar is perfect for cavity
loor installations. With minimal parts, push-it assembly and a
complementary range of loor boxes and grommets, this lexible,
easy to install system can be reconigured as ofice layouts evolve.
The system consists of continuous lengths of track which are fed via
a feed unit and can be installed in loor voids as low as 48mm.
63 A rated, IP 40 protection
Available in ive versions: single phase, clean earth, dual circuit,
three phase and auxiliary earth
Tinned busbar version available for use within Abu Dhabi
(see page 15)
Available in 1.2m, 1.8m, 2.4m and 3.6m lengths
Tap-off outlets are located at every 300 or 600mm pitch
Floor mountable (stand-off brackets also available)
UNDERFLOOR TO WORKSTATION
WWW.LEGRAND.CO.UK/ELECTRAK

SYSTEM GUIDE

Electrak powertrack / underfloor busbar


selection chart

Description

Length (m)

Track lengths with 300 mm socket centres


4 outlets

12

6 outlets

18

8 outlets

24

12 outlets

36

Track feeds

Excluding cables and conduit


Fexible metal conduit
Fexible metal conduit

Standard tap-off / auxillary earth tap-off


32 A unfused 16 mm L, N, PE
13 A fused 16 mm L, N, PE
13 A 5437 fused 16 mm L, N, PE

3
5
3
5
3
5

Low noise / clean earth tap-off


32 A unfused 16 mm CE, L, N, PE
13 A fused 16 mm CE, L, N, PE
13 A 5437 fused 16 mm CE, L, N, PE

3
5
3
5
3
5

Dual circuit tap-off


3
32 A unfused 20 mm CE, L1, N1 L2, N2, PE
5
3 phase tap-off
32 A 415 V 3 phase 20 mm L1, L2, L3, N, PE
32 A L1 unfused reconfigurable live pin 16 mm L1, N, PE
32 A L2 unfused reconfigurable live pin 16 mm L2, N, PE
32 A L3 unfused reconfigurable live pin 16 mm L3, N, PE

3
5
3
5
3
5
3
5

Key code / Busbar arrangement

008_009_Electrak 2014 v3.indd 8

27/08/2014 13:07

ELECTRAK 24
Standard system
(white)

ELECTRAK 25
Low noise / clean
earth system (green)

ELECTRAK 26
Dual circuit
system (dark green)

ELECTRAK 27
3 phase
system (grey)

ELECTRAK 28
Auxillary earth
system (red)

DA1123

JA2123

KA3123

NA4123

YA5123

DA1183

JA2183

KA3183

NA4183

YA5183

DA1243

JA2243

KA3243

NA4243

YA5243

DA1363

JA2363

KA3363

NA4363

YA5363

DF1010

JF2010

KF3010

NF4010

YF5010

DW1000

JW2000

KW3000

NW4000

YW5000

DW1010

JW2010

KW3010

NW4010

YW5010

DW1020

JW2020

KW3020

NW4020

YW5020

DP1332

DP1332

YP5332

DP1532

DP1532

YP5532

DP1313

DP1313

YP5313

DP1513

DP1513

YP5513

DP1327

DP1327

YP5327

DP1527

DP1527

YP5527

JP2332

JP2332

JP2532

JP2532

JP2313

JP2313

JP2513

JP2513

JP2327

JP2327

JP2527

JP2527

KP3328

KP3528

NZ4331
NZ4531
NP43321
NP45321
NP43021
NP45021
NP43031
NP45031

PE

N2 L2

PE CE N1 L1

PE CE N1 L1 N2 L2

PE N L1 L2 L3

PE N1 L1

1 : All NP tap-offs are reconfigurable between L1, L2 or L3 for 3 phase track

008_009_Electrak 2014 v3.indd 9

27/08/2014 13:05

Electrak 24 powertrack / underfloor busbar system


standard system (white)

DF1010

- - -/

---

DW1010

DA1123

DP1332

Selection charts p. 8-9


Dimensions and technical information p. 17-21
Approved to ASTA Standard 138 and ISO 9001 : 2008
Conforms to BS EN 60439-2 : 2008. Fully complies with the requirements of BS 7671 : 2008 IEE Wiring Regulations
A compact system that can be installed in floor voids as low as 48 mm
Pack

Cat. Nos.

Track system components

Pack

1
1
1

DA1123
DA1183
DA1243
DA1363

32 A unfused
1
1

Track feed unit


1

1
1
1

Can be used to overcome obstructions or


as corners where required
DW1000 Excluding cables and conduit
DW1010 12 m flexible metal conduit
DW1020 24 m flexible metal conduit

1
1

Required when track is raised off surface level


Brackets raise track by 21 mm and should be
spaced 600 mm apart
DZ1210 For fitting under track body and track feed
DZ1230 For fitting under integral track connectors

16 mm L, N, PE
DP1332 3 m
DP1532 5 m
13 A fused

DF1010 With one 25 mm diameter hole suitable for MICC,


armoured cables or single core cables in conduit
Flexible interlinks

Tap-off units
Tap-off length is determined by the cable and not
the conduit length, e.g. a 3 m tap-off has 3 m of
cable and 26 m of flexible metal conduit1
Tap-off units in excess of 3 m should only be used if
they contain a fuse or if the power track is protected
by a protective device not exceeding 32 A

Electrak 24 standard track lengths


Track lengths fit together using the integral
connectors on each length
Track lengths should always be secured using the
integral floor fixing brackets
300 mm socket centres
12 m, 4 outlets, 2 floor fixing brackets
18 m, 6 outlets, 2 floor fixing brackets
24 m, 8 outlets, 2 floor fixing brackets
36 m, 12 outlets, 3 floor fixing brackets

Cat. Nos.

1
1

16 mm L, N, PE
DP1313 3 m
DP1513 5 m
13 A 5437 fused - high integrity

1
1

16 mm L, N, PE
DP1327 3 m
DP1527 5 m

Special fixing brackets

1 : Tap-offs are supplied as standard with flexible metal conduit


For alternative wiring solutions, contact us on +44 (0) 845 600 6266

10

010_011_Electrak 2014 v2.indd 10

27/08/2014 12:44

Electrak 25 powertrack / underfloor busbar system


low noise / clean earth system (green)

JF2010

- - -/

---

JW2010

JA2123

JP2332

Selection charts p. 8-9


Dimensions and technical information p. 17-21
Approved to ASTA Standard 138 and ISO 9001 : 2008
Conforms to BS EN 60439-2 : 2008. Fully complies with the requirements of BS 7671 : 2008 IEE Wiring Regulations
A compact system that can be installed in floor voids as low as 48 mm
Pack

Cat. Nos.

Track system components

Pack

1
1
1
1

JA2123
JA2183
JA2243
JA2363

JF2010 With one 25 mm diameter hole suitable for MICC,


armoured cables or single core cables in conduit

32 A unfused
1
1

Track feed unit

Flexible interlinks

1
1
1

Can be used to overcome obstructions or


as corners where required
JW2000 Excluding cables and conduit
JW2010 12 m flexible metal conduit
JW2020 24 m flexible metal conduit

1
1

Required when track is raised off surface level


Brackets raise track by 21 mm and should be
spaced 600 mm apart
DZ1210 For fitting under track body and track feed
DZ1230 For fitting under integral track connectors

Tap-off units
Tap-off length is determined by the cable and not
the conduit length, e.g. a 3 m tap-off has 3 m of
cable and 26 m of flexible metal conduit1
Tap-off units in excess of 3 m should only be used if
they contain a fuse or if the power track is protected
by a protective device not exceeding 32 A

Electrak 25 low noise / clean earth track lengths


Track lengths fit together using the integral
connectors on each length
Track lengths should always be secured using the
integral floor fixing brackets
300 mm socket centres
12 m, 4 outlets, 2 floor fixing brackets
18 m, 6 outlets, 2 floor fixing brackets
24 m, 8 outlets, 2 floor fixing brackets
36 m, 12 outlets, 3 floor fixing brackets

Cat. Nos.

16 mm CE, L, N, PE
JP2332 3 m
JP2532 5 m
13 A fused

1
1

16 mm CE, L, N, PE
JP2313 3 m
JP2513 5 m
13 A 5437 fused - high integrity

1
1

16 mm CE, L, N, PE
JP2327 3 m
JP2527 5 m

Special fixing brackets

1 : Tap-offs are supplied as standard with flexible metal conduit


For alternative wiring solutions, contact us on +44 (0) 845 600 6266

11

010_011_Electrak 2014 v2.indd 11

27/08/2014 12:44

Electrak 26 powertrack / underfloor busbar system


dual circuit system (dark green)

KF3010

- - -/

---

KW3010

KA3123

KP3328

Selection charts p. 8-9


Dimensions and technical information p. 17-21
Approved to ASTA Standard 138 and ISO 9001 : 2008
Conforms to BS EN 60439-2 : 2008. Fully complies with the requirements of BS 7671 : 2008 IEE Wiring Regulations
A compact system that can be installed in floor voids as low as 48 mm
Pack

Cat. Nos.

Track system components

Pack

The dual power track system has both standard and


low noise / clean earth systems incorporated

1
1
1
1

KA3123
KA3183
KA3243
KA3363

Standard 32 A unfused
1
1

KF3010 With two 25 mm diameter holes suitable for MICC,


armoured cables or single core cables in conduit

1
1

1
1
1

Special fixing brackets

1
1

Required when track is raised off surface level


Brackets raise track by 21 mm and should be
spaced 600 mm apart
DZ1210 For fitting under track body and track feed
DZ1230 For fitting under integral track connectors

16 mm L, N, PE
DP1313 3 m
DP1513 5 m
Standard 13 A 5437 fused

Flexible interlinks
Can be used to overcome obstructions or
as corners where required
KW3000 Excluding cables and conduit
KW3010 12 m flexible metal conduit
KW3020 24 m flexible metal conduit

16 mm L, N, PE
DP1332 3 m
DP1532 5 m
Standard 13 A fused

Track feed unit


1

Tap-off units
Tap-off length is determined by the cable and not
the conduit length, e.g. a 3 m tap-off has 3 m of
cable and 26 m of flexible metal conduit1
Tap-off units in excess of 3 m should only be used if
they contain a fuse or if the power track is protected
by a protective device not exceeding 32 A

Electrak 26 dual circuit track lengths


Track lengths fit together using the integral
connectors on each length
Track lengths should always be secured using the
integral floor fixing brackets
300 mm socket centres
12 m, 4 outlets, 2 floor fixing brackets
18 m, 6 outlets, 2 floor fixing brackets
24 m, 8 outlets, 2 floor fixing brackets
36 m, 12 outlets, 3 floor fixing brackets

Cat. Nos.

1
1

16 mm L, N, PE
DP1327 3 m
DP1527 5 m
Low noise / clean earth 32 A unfused

1
1

16 mm CE, L, N, PE
JP2332 3 m
JP2532 5 m
Low noise / clean earth 13 A fused

1
1

16 mm CE, L, N, PE
JP2313 3 m
JP2513 5 m
Low noise / clean earth 13 A 5437 fused

1
1

16 mm CE, L, N, PE
JP2327 3 m
JP2527 5 m
Dual circuit 32 A unfused

1
1

20 mm CE, L1, N1, L2, N2,PE


KP3328 3 m
KP3528 5 m

1 : Tap-offs are supplied as standard with flexible metal conduit


For alternative wiring solutions, contact us on +44 (0) 845 600 6266

12

012_013_Electrak 2014 v2.indd 12

27/08/2014 12:45

Electrak 27 powertrack / underfloor busbar system


3 phase system (grey)

NF4010

- - -/

---

NW4010

NA4123

NZ4331

Selection charts p. 8-9


Dimensions and technical information p. 17-21
Approved to ASTA Standard 138 and ISO 9001 : 2008
Conforms to BS EN 60439-2 : 2008. Fully complies with the requirements of BS 7671 : 2008 IEE Wiring Regulations
A compact system that can be installed in floor voids as low as 48 mm
Pack

Cat. Nos.

Track system components

Pack

1
1
1
1

NA4123
NA4183
NA4243
NA4363

NF4010 With one 25 mm diameter hole suitable for MICC,


armoured cables or single core cables in conduit

32 A 415 V 3 phase
1
1

Track feed unit

1
1
1

1
1

Required when track is raised off surface level


Brackets raise track by 21 mm and should be
spaced 600 mm apart
DZ1210 For fitting under track body and track feed
DZ1230 For fitting under integral track connectors

20 mm L1, L2, L3, N, PE


NZ4331 3 m
NZ4531 5 m
32 A L12 unfused

Flexible interlinks
Can be used to overcome obstructions or
as corners where required
NW4000 Excluding cables and conduit
NW4010 12 m flexible metal conduit
NW4020 24 m flexible metal conduit

Tap-off units
Tap-off length is determined by the cable and not
the conduit length, e.g. a 3 m tap-off has 3 m of
cable and 26 m of flexible metal conduit1
Tap-off units in excess of 3 m should only be used if
they contain a fuse or if the power track is protected
by a protective device not exceeding 32 A

Electrak 27 3 phase track lengths


Track lengths fit together using the integral
connectors on each length
Track lengths should always be secured using the
integral floor fixing brackets
300 mm socket centres
12 m, 4 outlets, 2 floor fixing brackets
18 m, 6 outlets, 2 floor fixing brackets
24 m, 8 outlets, 2 floor fixing brackets
36 m, 12 outlets, 3 floor fixing brackets

Cat. Nos.

1
1

Unfused
Reconfigurable live pin
16 mm L, N, PE
NP4332 3 m
NP4532 5 m
32 A L22 unfused

Special fixing brackets


1
1

Unfused
Reconfigurable live pin
16 mm L, N, PE
NP4302 3 m
NP4502 5 m
32 A L32 unfused

1
1

Unfused
Reconfigurable live pin
16 mm L, N, PE
NP4303 3 m
NP4503 5 m

1 : Tap-offs are supplied as standard with flexible metal conduit


For alternative wiring solutions, contact us on +44 (0) 845 600 6266
2 : All NP tap-offs are reconfigurable between L1, L2, or L3 for
3 phase track

13

012_013_Electrak 2014 v2.indd 13

27/08/2014 12:45

Electrak 28 powertrack / underfloor busbar system


auxiliary earth system (red)

YF5010

- - -/

---

YW5010

YA5123

YP5332

Selection charts p. 8-9


Dimensions and technical information p. 17-21
Approved to ASTA Standard 138 and ISO 9001 : 2008
Conforms to BS EN 60439-2 : 2008. Fully complies with the requirements of BS 7671 : 2008 IEE Wiring Regulations
A compact system that can be installed in floor voids as low as 48 mm
Pack

Cat. Nos.

Track system components

Pack

1
1
1
1

YA5123
YA5183
YA5243
YA5363

YF5010 With one 25 mm diameter hole suitable for MICC,


armoured cables or single core cables in conduit

32 A unfused
1
1

Track feed unit

Flexible interlinks

1
1
1

Can be used to overcome obstructions or


as corners where required
YW5000 Excluding cables and conduit
YW5010 12 m flexible metal conduit
YW5020 24 m flexible metal conduit

1
1

Required when track is raised off surface level


Brackets raise track by 21 mm and should be
spaced 600 mm apart
DZ1210 For fitting under track body and track feed
DZ1230 For fitting under integral track connectors

Tap-off units
Tap-off length is determined by the cable and not
the conduit length, e.g. a 3 m tap-off has 3 m of
cable and 26 m of flexible metal conduit1
Tap-off units in excess of 3 m should only be used if
they contain a fuse or if the power track is protected
by a protective device not exceeding 32 A

Electrak 28 auxiliary earth track lengths


Track lengths fit together using the integral
connectors on each length
Track lengths should always be secured using the
integral floor fixing brackets
300 mm socket centres
12 m, 4 outlets, 2 floor fixing brackets
18 m, 6 outlets, 2 floor fixing brackets
24 m, 8 outlets, 2 floor fixing brackets
36 m, 12 outlets, 3 floor fixing brackets

Cat. Nos.

16 mm L, N, PE
YP5332 3 m
YP5532 5 m
13 A fused

1
1

16 mm L, N, PE
YP5313 3 m
YP5513 5 m
13 A 5437 fused - high integrity

1
1

16 mm L, N, PE
YP5327 3 m
YP5527 5 m

Special fixing brackets

1 : Tap-offs are supplied as standard with flexible metal conduit


For alternative wiring solutions, contact us on +44 (0) 845 600 6266

14

014_Electrak 2014 v2.indd 14

27/08/2014 12:46

Electrak 28R
tinned powertrack...

As a specific requirement for use within


Abu Dhabi, Legrand has developed a
tinned busbar which has been designed
in line with the guidance for busways
outlined by the Abu Dhabi Distribution
Company (ADDC), as detailed below.

Designed to meet local standards

Appendix 8. Colour identification for cables

Guideline For Design, Testing and Installation Of


Busways GL.GN.01. Issued by: Abu Dhabi Distribution Co.
Low Voltage Switchgear Committee
Issue: 2, Revision: 1, effective 01/02/2012

Conductor
Colour
Non-lexible ixed wiring and all 3 phase cables:
Phase 1
Red

16. Lighting & Small Power Busways & Modular Wiring


Lighting & Power Socket bus duct and modular wiring are considered
part of building wiring and regulated by the Electricity Wiring Regulation
issued by RSB. It shall comply with respective specifications under the
Wiring regulation. ADDC LVSGC approves these methods in principle
provided that the RSB set aspects are incorporated (like tinning of copper,
colour coding etc.).
Guideline For Design, Testing and Installation Of Busways GL.GN.01
Copyright Abu Dhabi Distribution Co.

Developed to meet the ADDC requirements for busways, this specially


designed range sees all busbars tinned along their entire length, and
all busbar connectors and tap-off blades plated.
Approved to ASTA standard 138 and designed to be in accordance with
the requirements of BS EN 60439-2: 2000 and BS EN 61534-22: 2009
(IEC 61534: 2009).

Phase 2

Yellow

Phase 3

Blue

Neutral

Black

Earth conductors

Green / yellow

The Electrak 28R powertrack range is a single


phase system and therefore adopts red (L), black
(N), and green/yellow (E) cables to meet with the
requirments of The Regulation and Supervision
Bureau of the Water, Wastewater and Electricity
Sector in the Emirate of Abu Dhabi.

Appendix 9. Capacity of conduits and trunking


Diameter of Conduit (mm )
20
25
32
Maximum number of conductors
7
12
2

Conduit
(mm )
2

1.5
2.5

12

4.0

The tap-offs contain a maximum of 3 x 4mm


conductors housed in as 20mm metal lexible
conduit to meet the requirements of The
Regulation and Supervision Bureau of the Water,
Wastewater and Electricity Sector in the Emirate
of Abu Dhabi.
2

Electrak 28R tinned tap-offs

Electrak 28R tinned busbar connectors

The Electrical Wiring Regulations 2007


Issued by: The Regulation and Supervision Bureau for the
Water, Wastewater and Electricity Sector in the Emirate of
Abu Dhabi. Revision 1, January 2009

NOTE: When designing installations in regions


with higher ambient temperatures than 35C,
de-rating factors may need to be applied. Please
refer to the table on page 21 for details.

7.7 Busways, bus ducts ad busbar risers


7.7.6 Busways, bus ducts and busbar risers shall have neutral conductors
of equal size to the phase conductors and shall have a dedicated Earth
Conductor. The use of the metal casing as an earth conductor permitted
only for Earth Leakage Protected Installations, and with the prior approval
of the Distribution Company.
The Electrical Wiring Regulations 2007 - Copyright The Regulation and Supervision Bureau (RSB)

The Electrak powertrack system uses equal size tinned copper


busbars for live, neutral and earth conductors to meet with the
requirements of The Regulation and Supervision Bureau of the Water,
Wastewater and Electricity Sector in the Emirate of Abu Dhabi.
UNDERFLOOR TO WORKSTATION
WWW.LEGRAND.CO.UK/ELECTRAK

SYSTEM GUIDE

15

Electrak 28R tinned powertrack / underfloor busbar system


auxiliary earth system (red)

YF5010R

- - -/

---

YW5010R

YA5123R

YP5332R

Selection charts p. 8-9


Dimensions and technical information p. 17-21
Approved to ASTA Standard 138 and ISO 9001 : 2008
Conforms to BS EN 60439-2 : 2008. Fully complies with the requirements of BS 7671 : 2008 IEE Wiring Regulations
A compact system that can be installed in floor voids as low as 48 mm
Pack

Cat. Nos.

Busbar system components

Pack

1
1
1
1

YA5123R
YA5183R
YA5243R
YA5363R

YF5010R With one 25 mm diameter hole suitable for MICC,


armoured cables or single core cables in conduit

32 A unfused
1
1

Feed unit

Flexible interlinks

1
1
1

Tap-off units
Tap-off length is determined by the cable and not the
conduit length, e.g. a 3 m tap-off has 3 m of cable
and 26 m of flexible metal conduit1
Tap-off units in excess of 3 m should only be used if
they contain a fuse or if the busbar run is protected
by a protective device not exceeding 32 A

63A auxiliary earth busbar lengths


Busbar lengths fit together using the integral
connectors on each length
Lengths should always be secured using the integral
floor fixing brackets
300 mm socket centres
12 m, 4 outlets, 2 floor fixing brackets
18 m, 6 outlets, 2 floor fixing brackets
24 m, 8 outlets, 2 floor fixing brackets
36 m, 12 outlets, 3 floor fixing brackets

Cat. Nos.

20 mm L, N, PE (4 mm2)
YP5332R 3 m
YP5532R 5 m
13 A 5437 fused - high integrity

1
1

20 mm L, N (25 mm2), PE (4 mm2)


YP5327R 3 m
YP5527R 5 m

Can be used to overcome obstructions or


as corners where required
YW5000R Excluding cables and conduit
YW5010R 12 m flexible metal conduit
YW5020R 24 m flexible metal conduit
Special fixing brackets

1
1

Required when busbar is raised off surface level


Brackets raise the system by 21 mm and should be
spaced 600 mm apart
DZ1210 For fitting under lengths and feed units
DZ1230 For fitting under integral connectors

1 : Tap-offs are supplied as standard with flexible metal conduit


For alternative wiring solutions, contact us on +44 (0) 845 600 6266

16

016_Electrak 2014 v2.indd 16

27/08/2014 14:33

Electrak powertrack / underfloor busbar


design and installation
n General installation notes

n Special fixing brackets

Electrak power track is a compact system that can be installed in floor


voids as low as 48 mm

Electrak special fixing brackets are available to raise the system by


21 mm. Ensure brackets are spaced 600 mm apart and always have
support under the integral connectors and feed units. Failure to do so
may undermine the integrity of the system

Feed units are provided with one or two 25 mm diameter holes suitable
for MICC, armoured cables or single core cables in conduit
Track lengths connect together and to feed units using the integral
connectors on each length
Lengths should always be secured using the integral floor fixing
brackets ; three on the 36 m length and two on 24 m, 18 m or 12 m
lengths

Cat. No. DZ1210 raised off-floor fixing brackets are spaced at 600 mm
centres along the busbar run. Also use bottom half of bracket under
feed unit and flexible interlink
Cat. No. DZ1230 raised off-floor fixing brackets are always used under
integral connectors. Busbar is secured to raised brackets using the
integral fixing bracket

Access to power is provided along the busbar length by simply


plugging tap-off units into shuttered socket outlets. These tap-off
units feed all types of conventional floor service outlet boxes or
feed workstations directly through the floor via insulated conductors
contained in flexible metal or VO rated nylon conduit. When connecting
tap-offs directly through the floor via grommet outlets to workstations
care must be taken to ensure that the tap-off length is adequate
Integral fixing bracket
screws to special bracket

The dual system has both standard and low noise / clean earth
systems incorporated. As well as dual tap-offs, both standard and low
noise / clean earth tap-offs can be plugged into any socket outlet along
the busbar length. The dual tap-off incorporates both standard and low
noise cables
Optimum layout flexibility is achieved by positioning busbar lengths a
maximum of 52 m apart and 25 m from the wall, and by connecting
the 3 m tap-off units to floor outlet boxes. This means every part of the
floor area can be served. Flexible interlinks can be used to overcome
obstructions or used as corners if required

Integral connector

50 mm

185 mm

7 mm

7 mm

99 mm

Cat. No. DZ1210

21 mm to underside and
36 mm to top of busbar length

Cat. No. DZ1230

n Dimensions

75

93

250
46

46

109

68

118

47

32
15

2 x 25

25

65

End view A

End view B

92

Integral fixing
bracket fixing
centres

25 m

Example floor layout

feed unit

52 m

52 m

52 m

socket outlet points every


300 or 600 mm along
busbar run

3 m flexible
tap-off unit

floor service
outlet box

integral
connectors

All dimensions (mm) are nominal

17

017_019_Electrak 2014 v3.indd 17

27/08/2014 12:48

Electrak powertrack / underfloor busbar system


design and installation (continued)
n Product configuration
Tap-off connection

Flexible interlink
Flexible interlink boxes
must be securely fixed
inline to surface so no
movement can take place
after fixing

Depress tap-off side clips and push down


Tap-off

Side clip
Push down

Interlink feed
entry socket.
Remove dust
cover label

Make sure both tapoff side clips are fully


pushed home on both
sides of tthe bar

Remove dust cover


from end entry
socket before use

Screw fix to surface

Feed unit (Cat. No. DF1010) Sub-cabling

Tap-off connection
Tap-off metal
flexible conduit

Feed unit protective earth


terminal and earth bond
Protective earth must
always be connected via
the earth terminal block

Lift lid

20 mm conduit fitting.
Tighten back nut securely

Connector terminals

Lift terminal tab to access


terminal screws and close
after use

25 mm cable
conduit fixing hole
Close lid and secure with lid
fixing screw before power up

Feed unit (Cat. No. JF2010) Sub-cabling

Tap-off connection
Tap-off metal
flexible conduit

Feed unit protective earth


terminal and earth bond
Protective earth must
always be connected via
the earth terminal block

Lift lid

20 mm conduit fitting
Tighten back nut securely

Connector terminals

Lift terminal tab to access


terminal screws and close
after use
Clean earth
25 mm cable
conduit fixing hole
Close lid and secure with lid
fixing screw before power up

All dimensions (mm) are nominal

18

017_019_Electrak 2014 v3.indd 18

27/08/2014 12:48

Feed unit (Cat. No. KF3010) Sub-cabling

Dual tap-off connection (dark green)


Tap-off metal
flexible conduit

Lift terminal tab to access


terminal screws and close
after use
Feed unit protective
earth terminal and
earth bond

Protective earth
must always be
connected via the
earth terminal block

Lift lid

20 mm conduit fitting
Tighten back nut securely

Connections
L1, N1, CE = low noise
L2, N2, PE = standard

Connections
L1, N1, CE = low noise
L2, N2, PE = standard Connector terminals
Clean earth
2 x 25 mm
cable conduit
fixing hole
Close lid and secure with lid
fixing screw before power up

3 phase tap-off connection

Feed unit (Cat. No. NF4010) Sub-cabling

Tap-off metal
flexible conduit
Feed unit protective earth
terminal and earth bond
Protective earth must
always be connected via
the earth terminal block

Lift lid

20 mm conduit fitting
Tighten back nut securely

Connector terminals

Lift terminal tab to access


terminal screws and close
after use

25 mm cable
conduit fixing hole
Close lid and secure with lid
fixing screw before power up

Tap-off connection

Feed unit (Cat. No. YF5010 and YF5010R) Sub-cabling

Tap-off metal
flexible conduit
Feed unit protective earth
terminal and earth bond
Protective earth must
always be connected via
the earth terminal block

Lift lid

20 mm conduit fitting
Tighten back nut securely

Connector terminals

Lift terminal tab to access


terminal screws and close
after use

25 mm cable
conduit fixing hole
Close lid and secure with lid
fixing screw before power up

All dimensions (mm) are nominal

19

017_019_Electrak 2014 v3.indd 19

27/08/2014 12:49

Electrak powertrack / underfloor busbar system


installation (continued)

1 Fix feed unit to surface


Feed unit
Direction of
busbar run

Make chalk line to


align busbar lengths

2 Connect busbar length to feed unit


Remove
dust cover

Integral
connector
Busbar length

Push down

Make sure connector


clips are fully pushed
home on both sides

Push down

Feed unit

Additional
length

3 Connect additional busbar lengths


Remove dust cover
before connecting
additional lengths

First fixing
bracket

Tap-off outlets
reusable plastic
dust covers
Pull out fixing bracket
lugs and screw fix on
both sides

4 Secure busbar lengths to surface

All integral fixing brackets must


be fixed to surface at 12 m fixing
centres from first bracket on each
busbar length

All dimensions (mm) are nominal

20

020_021_Electrack 2014 v2.indd 20

27/08/2014 12:50

Electrak powertrack / underfloor busbar system


technical data
n Standards

Volt drops (live and neutral)

Approved to ASTA Standard 138


BS EN 60439-2 : 2000, BS EN 61534-22 : 2009
and IEC 61534-22 : 2009
Manufactured within an approved ISO 9001 : 2008 and ISO 14001 : 2004 facility
Assessed Quality Assurance Certificate No. 2029
Electrak powertrack / underfloor busbar fully complies with the requirements of
BS 7671 : 2008 + A1 : 2011 (IET Wiring Regulations)

n Ambient temperature rating factors

The current carrying capacity for a powertrack / underfloor busbar (In) is affected
by the ambient temperature
For Electrak powertrack / underfloor busbar the ambient rating factor Ka is equal
to 1 for ambient temperatures up to and including 35 C
Iz = Ka In
Where :
Iz = effective current carrying capacity for continuous service under particular
installation conditions
Ka = ambient temperature factor
In = nominal current carrying capacity
For ambient temperatures exceeding 35 C the values of Ka and Iz are given in
the following tables
Powertrack / underfloor busbar system
Ambient
20C
25C
30C
Ka
1
Iz
63 A

35C

40C
095
59 A

45C
085
53 A

50C
080
50 A

32 A unfused tap-off (using thermosetting 90C cables)


Ambient
20C
25C
30C
35C
40C
Ka
1
095
Iz
32 A
30 A

45C
085
27 A

50C
080
25 A

Busbars
Cable connector
Integral connector
32 A tap-off
+ 4 mm2 cable
Flexible corner assembly
+ 10 mm2 cable
Mechanical data
Number of conductors
Busbar conductor cross sectional area
Housing cross sectional area (copper equivalent)
Cable terminal capacity
Tap-off cable 32 A
Tap-off cable 13 A fused
Tap-off conduit, up to 4 conductors
Tap-off conduit, 5 and 6 conductors
Flexible corner cable (tri-rated, high temperature)
Flexible corner conduit
IP rating

50C

References :
BS 7671 : 2008 incorporating amendment No. 1 : 2011
Appendix 8 Current carrying capacity for powertrack systems
Appendix 4 Table 4B1 Rating factors for thermosetting cables
Appendix 4 Table 4E1A Single core 90C thermosetting insulated cables
(non-armoured)

n Earth fault loop impedance

BS 7671 : 2008 + A1 : 2011 IET Wiring Regulations require accurate


determination of the total earth loop impedance, which must be sufficiently low to
allow the protective device to operate within the specified time, which for socket
outlets is 04 seconds. The values relevant to Electrak for calculating the earth
fault loop impedance are shown in the electrical test data table, see opposite

n Durability

Electrak systems are superbly designed and extremely robust. They can
be expected to stand up to all normal site conditions. Electrak powertrack /
underfloor busbar has been short circuit strength tested by ASTA

n Installations with high protective conductor currents


All unfused tap-offs comply with Regulation 5437 without the need for additional
earth conductors. Regulation 54371103 (ii) states a single copper protective
conductor having a cross-sectional area of not less than 4 mm2, complying
with the requirements of Regulations 5432 and 5433, the protective conductor
being enclosed to provide additional protection against mechanical damage, for
example, within a flexible conduit
For installations with high protective conductor currents requiring
fused tap-offs, a 5437 compliant tap-off must be used. Normally fused tap-offs
incorporate 15 m2 (25 m2 for tinned system) conductors, however in the fused
5437 tap-offs, the 15 m2 (25 m2 for tinned system) earth conductor is replaced
with a 4 mm2 conductor and therefore complies with Section 54371103 (ii)

n 32 A tap-off unit

The 3 m 32 A tap-off unit comprises an unfused tap-off with 26 m of flexible


metal conduit with integral 4 mm2 LSOH conductors
These units are designed to comply with regulation 43421 of the
IET Wiring Regulations by virtue of the following :
maximum length of cable is 3 m
it is factory assembled and fully tested item with cable installed in high quality
flexible conduit

E24 E28

E28R

3-6
13 mm2
13 mm2
16 mm2
4 mm2
15 mm2
16 mm
20 mm2
10 mm2
25 mm
40

3
13 mm2
13 mm2
16 mm2
4 mm2
25 mm2
20 mm
N/A
10 mm2
25 mm
40

Material specifications
Housing - busbar lengths

13 A fused tap-off (using 25 mm2 thermosetting 90C cables)


Ambient
20C
25C
30C
35C
40C
45C
Ka
1
Iz
13 A

30 mV/A/m
04 mV/A
04 mV/A
04 mV/A
11 mV/A/m
15 mV/A
40 mV/A/m

Busbar insulator

Galvanised steel, natural finish


High conductivity copper
(Tinned version is electro-tin plated)
PTFE

Integral connectors / Tap-off outlets


Tap-off outlet entry shutter
Tap-off housing
Integral connector blades
Tap-off blades
Tap-off/flexible corner conduit, metal
Tap-off cable
Flexible interlink cable
Feed box/flexible interlink boxes
Feed connector terminals/earth block
Fixing brackets
13 A tap-off, fuse

Flame retardant polycarbonate


Acetal
Flame retardant polycarbonate
Copper (Tinned version is plated)
Copper (Tinned version is plated)
Electro-galvanised steel
LSOH to BS 7211
Tri-rated to BS 6231
Galvanised steel
Brass (Tinned version is plated)
Galvanised steel
To BS 1362, ASTA approved

Earth fault loop impedance


Phase busbar
Earth busbar
Earth housing
Earth busbar and housing
Cable connector
Integral connector
32 A tap-off
+ 4 mm2 cable
Flexible corner assembly
+ 10 mm2 cable
Rated conditional short-circuit current
Ambient temperature

15 m/m
15 m/m
11 m/m
08 m/m
04 m
06 m
06 m
11 m/m
15 m
40 m/m
16 KA
25C

Busbars

Electrical test data


Rated current
Rated voltage
Frequency
Conductor resistance - live and neutral
Conductor impedance

63 A
230/400 V~
50/60 Hz
30 m/m
15 m/m

Fault condition protection for the tap-off assembly and the floor box socket outlets
is delivered by the circuit protection device
Disconnection time for socket outlets is 04 seconds (Regulation 411322). The
Electrak system meets this requirement
Tap-off units in excess of 3 m should only be used if they contain a fuse
or the busbar run is protected by a protective device not exceeding 32 A

All dimensions (mm) are nominal

21

020_021_Electrack 2014 v2.indd 21

27/08/2014 12:50

Floor boxes...
choice, flexibility and
easy installation

2, 3 and 4 compartment raised access


loor boxes and slab boxes offer complete
versatility. Floor boxes are available pre-wired
with power track tap-off, or supplied empty
(unassembled), with a choice of single or
separate compartment bases and three depth
options. With a vast selection of power and
data plates available, boxes can be tailored
to the speciic requirements of each ofice
installation.

22

Rapid fit /remove mechanism


adjusts for flooring thickness

Quick-fit, reversible lid for


rapid installation

Durable ABS trim and


lid surround

Various RCD protection


options available

Available pre-wired with


tap-off

Rapid fit push lock secures


base in floor aperture

Three depth options:


75mm, 85mm, 110mm

Single or separate
compartment bases

Available in 2, 3 and 4 compartments and with a choice of


three depths, Electrak loor boxes have been developed
with a host of special features:
Available pre-wired with tap-off or supplied unassembled
A vast selection of power and data plates,
including RCD options
Single or separate compartment bases for ease of data
cabling
Rapid installation and fast ratchet mechanism which
adjusts to loor inish thickness

UNDERFLOOR TO WORKSTATION
WWW.LEGRAND.CO.UK/ELECTRAK

SYSTEM GUIDE

23

access floor service outlet and slab mounted floor boxes


empty boxes and accessory plates

2 compartment

290

mm

mm

mm

mm

230

230

230

To configure boxes as required, select :


1. Box depth
2. Number of compartments required
3. Desired accessory plates

4 compartment

3 compartment

366

mm

366

100 mm
width plates

100 mm
width plates

Single base 75 mm depth

CR2001

CR011

CR4001

Single base 85 mm depth (standard box)

CR2002

CR012

CR4002

Single base 110 mm depth

CR2003

CR013

CR4003

Separate compartment base 75 mm depth

CR2004

CR014

CR4004

Separate compartment base 85 mm depth

CR2005

CR015

CR4005

Separate compartment base 110 mm depth

CR2006

CR016

CR4006

Empty boxes

Slab boxes
Fix directly onto floor slab (supplied empty)
Accessory plates

Example

1 compartment

2 compartment

3 compartment

CR5102

CR5202

CR5302

For 1, 2 and 3 compartment boxes

mm

75 mm
width plates

4 compartment
CR5402
For 4 compartment boxes

Blank plate

CR020

CR4100

2 gang switched socket outlet

CR022

CR4101

2 gang switched socket outlet,


low noise / clean earth

CR023

CR4102

2 gang non-standard switched socket outlet

CR027

CR4103

2 gang unswitched socket outlet

CR029

CR4104

3 gang unswitched socket outlet

CR030

CR4105

3 gang unswitched socket outlet,


low noise / clean earth

CR044

CR4118

2 gang RCD socket outlet

CR036

CR4111

2 gang RCD socket outlet,


low noise / clean earth

CR043

CR4117

Punched plate for 2 x 1 gang accessories


(603 mm fixing centres)

CR026

Punched plate for 2 gang accessories


(1206 mm fixing centres)

CR028

Angled punched plate for 4 x RJ45 sockets


(37 mm x 22 mm cut-outs)

CR042

CR4115

2 x LJ2 accessory plate (50 mm fixing centres)

CR031

CR4106

4 x BNC connector plate

CR033

CR4108

4 x Data / telecoms plate


(37 mm x 22 mm cut-outs)

CR024

CR4112

6 x Data / telecoms plate


(37 mm x 22 mm cut-outs)

CR025

CR4113

24

024_Electrak 2014 v1.indd 24

27/08/2014 12:51

access floor pre-wired service outlet boxes


and accessory plates

Pre-wired service outlet boxes with Electrak tap-offs


1. Select power track tap-off and desired configuration
2. Select additional accessory plates (if required)
Includes 1 x twin
switched socket outlet

Includes 2 x twin
switched socket outlet

Includes 1 x 2 gang
RCD socket outlet

Includes 2 x 2 gang
RCD socket outlet

DP1332 - 3 m

CR100

CR102

CR100R

CR102R

DP1532 - 5 m

CR101

CR103

CR101R

CR103R

JP2332 - 3 m

CR110

CR112

CR110R

CR112R

JP2532 - 5 m

CR111

CR113

CR111R

CR113R

YP5332 - 3 m

CR104

CR106

CR104R

CR106R

YP5532 - 5 m

CR105

CR107

CR105R

CR107R

3 compartment
Electrak 24 - standard tap-off

230

Electrak 25 - low noise /


clean earth tap-off

mm
366

mm

Electrak 28 - auxiliary earth tap-off

Additional plates for 3 compartment boxes


Blank plate

CR020

2 x LJ2 accessory plate


(50 mm fixing centres)

CR031

Punched plate for 2 x 1 gang accessories


(603 mm fixing centres)

CR026

4 x BNC connector plate

CR033

Punched plate for 2 gang accessories


(1206 mm fixing centres)

CR028

4 x Data / telecoms plate


(37 mm x 22 mm cut-outs)

CR024

Angled punched plate for 4 x


RJ45 sockets (37 mm x 22 mm cut-outs)

CR042

6 x Data / telecoms plate


(37 mm x 22 mm cut-outs)

CR025

Includes 1 x twin
switched socket
outlet

Includes 2 x twin
switched socket
outlet

Includes 1 x 2 gang
RCD socket outlet

Includes 2 x 2 gang
RCD socket outlet

Modular RCD
protecting 2 x twin
switched socket
outlets and 1 spare
compartment

DP1332 - 3 m

CR120

CR122

CR120R

CR122R

CR4402

DP1532 - 5 m

CR121

CR123

CR121R

CR123R

CR4403

JP2332 - 3 m

CR130

CR132

CR130R

CR132R

CR4412

JP2532 - 5 m

CR131

CR133

CR131R

CR133R

CR4413

YP5332 - 3 m

CR124

CR126

CR124R

CR126R

CR4406

YP5532 - 5 m

CR125

CR127

CR125R

CR127R

CR4407

4 compartment
Electrak 24 - standard tap-off

Electrak 25 - low noise /


clean earth tap-off
230
mm
366

mm

Electrak 28 - auxiliary earth tap-off

Additional plates for 4 compartment boxes


Blank plate

CR4100

4 x BNC connector plate

CR4108

Angled punched plate for 4 x


RJ45 sockets (37 mm x 22 mm cut-outs)

CR4115

4 x Data / telecoms plate


(37 mm x 22 mm cut-outs)

CR4112

2 x LJ2 accessory plate


(50 mm fixing centres)

CR4106

6 x Data / telecoms plate


(37 mm x 22 mm cut-outs)

CR4113

25

025_Electrak 2014 v1.indd 25

27/08/2014 12:51

access floor service outlet boxes

slab mounted floor boxes

empty boxes

empty boxes

CR5302

CR4002
3 compartment slab floor box shown with two twin
switched socket outlets, punched data plate and a
power track tap-off
CR5102
CR012

Selection charts p. 24
Dimensions and technical information p. 29
Lid and trim mouldings are precision engineered from hard wearing
durable ABS. The lid is reinforced with a galvanised mild steel plate
Mounting frame and box base - 09 mm thick galvanised steel
Each compartment has 2 entries for 20 mm and 2 entries for 25 mm
flexible conduits
Grey mouldings. Alternative colours available to special order. Goosewing
grey plates
2, 3 and 4 compartment boxes are also available with separate individual
compartment base units for convenient offsite pre-wiring
Supplied in parts or fully assembled and configured to customer
specification
Conform to IEC-61534-22
Pack

Cat. Nos.

2 compartment floor boxes

Selection charts p. 24
Dimensions and technical information p. 29
Electrak slab floor boxes are an ideal solution for underfloor power and
data requirements
Used in conjunction with Electrak floor grommets, slab boxes prevent
unwanted access to power and data connections

Pack

Empty boxes
CR2001
CR2002
CR2003
CR2004
CR2005
CR2006

Single base - 75 mm depth


Single base - 85 mm depth (standard box)
Single base - 110 mm depth
Separate compartment base - 75 mm depth
Separate compartment base - 85 mm depth
Separate compartment base - 110 mm depth

3 compartment floor boxes


Empty boxes
100 mm compartment widths
1
1
1
1
1
1

CR011
CR012
CR013
CR014
CR015
CR016

Single base - 75 mm depth


Single base - 85 mm depth (standard box)
Single base - 110 mm depth
Separate compartment base - 75 mm depth
Separate compartment base - 85 mm depth
Separate compartment base - 110 mm depth

Slab floor boxes


Fixes directly onto floor slab
Fast and efficient installation with integrated fixing
plates
Wide range of power and data accessory plates
Manufactured from 09 mm thick galvanised steel
Each compartment has 2 entries for 20 mm and
2 entries for 25 mm flexible conduits

100 mm compartment widths


1
1
1
1
1
1

Cat. Nos.

100 mm compartment widths

1
1

Use plates from the 1, 2 and 3 compartment floor box


section p. 24
CR5102 1 compartment slab floor box
CR5202 2 compartment slab floor box
CR5302 3 compartment slab floor box
75 mm compartment widths
Use plates from the 4 compartment floor box section
p. 24

CR5402 4 compartment slab floor box

4 compartment floor boxes


Empty boxes
75 mm compartment widths
1
1
1
1
1
1

CR4001
CR4002
CR4003
CR4004
CR4005
CR4006

Single base - 75 mm depth


Single base - 85 mm depth (standard box)
Single base - 110 mm depth
Separate compartment base - 75 mm depth
Separate compartment base - 85 mm depth
Separate compartment base - 110 mm depth

Screed / edge trim boxes, and metal


or lockable lids are available to order
contact us on +44 (0) 845 600 6266

26

026_027_Electrak v1.indd 26

27/08/2014 13:59

access floor service outlet boxes


accessory plates and ancillary items

Selection charts p. 24-25


Dimensions and technical information p. 29
Lid and trim mouldings are precision engineered from hard wearing durable ABS. Lid is reinforced with a galvanised mild steel plate
Mounting frame and box base - 09 mm thick galvanised steel
Each compartment has 2 entries for 20 mm and 2 entries for 25 mm flexible conduits
Grey mouldings. Alternative colours available to special order. Goosewing grey plates
2, 3 and 4 compartment boxes are also available with separate individual compartment base units for convenient offsite pre-wiring
Supplied in parts or fully assembled and configured to customer specification
Conform to IEC-61534-22
Pack

Cat. Nos.

1
1
1
1
1
1

CR020
CR022
CR023
CR027
CR029
CR030
CR044

1
1
1

CR036
CR043
CR026

CR028

CR042

1
1
1
1

CR031
CR033
CR024
CR025

1, 2 and 3 compartment accessory plates

Pack

Cat. Nos.

1
1
1
1
1
1

CR4100
CR4101
CR4102
CR4103
CR4104
CR4105
CR4118

1
1
1

CR4111
CR4117
CR4115

1
1
1
1

CR4106
CR4108
CR4112
CR4113

100 mm width
Blank plate
2 gang switched socket outlet
2 gang switched socket outlet, low noise / clean earth
2 gang non-standard switched socket outlet
2 gang unswitched socket outlet
3 gang unswitched socket outlet
3 gang unswitched socket outlet,
low noise / clean earth
2 gang RCD socket outlet
2 gang RCD socket outlet, low noise / clean earth
Punched plate for 2 x 1 gang accessories
(603 mm fixing centres)
Punched plate for 2 gang accessories
(1206 mm fixing centres)
Angled punched plate for 4 x RJ45
(37 mm x 22 mm cut-outs)
2 x LJ2 accessory plate (50 mm fixing centres)
4 x BNC connector plate
4 x Data / telecoms plate (37 mm x 22 mm cut-outs)
6 x Data / telecoms plate (37 mm x 22 mm cut-outs)

4 compartment accessory plates


75 mm compartment widths
Blank plate
2 gang switched socket outlet
2 gang switched socket outlet, low noise / clean earth
2 gang non-standard switched socket outlet
2 gang unswitched socket outlet
3 gang unswitched socket outlet
3 gang unswitched socket outlet,
low noise / clean earth
2 gang RCD socket outlet
2 gang RCD socket outlet, low noise / clean earth
Angled punched plate for 4 x RJ45
(37 mm x 22 mm cut-outs)
2 x LJ2 accessory plate (50 mm fixing centres)
4 x BNC connector plate
4 x Data / telecoms plate (37 mm x 22 mm cut-outs)
6 x Data / telecoms plate (37 mm x 22 mm cut-outs)

Ancillary items for service outlet boxes


1
1
10
10
50
1
1
1
1
1
10
1

CR0001
CR0003
CR0000
CR0010
CR0011
CR0012
CR0002
CR0004
CR0005

Floor tile cut-out template 2 compartment


Floor tile cut-out template 3/4 compartment
Cable outlet flap
Cable routers
Screws for accessory plates
Pack of 5 keys for use with lockable floor boxes
Lid 2 compartment box
Lid 3/4 compartment box
Mounting frame for vinyl floor. For 2 compartment box
Replaces mounting frame attached to base
CR0006 Mounting frame for vinyl floor. For 3/4 compartment
box. Replaces mounting frame attached to base
CR0007 Floor box lid handle
CR0020 Metal lid and trim - replacement for 3 and 4
compartment boxes - powder coated grey

Electrak tap-offs p. 10-14, 16

27

026_027_Electrak v1.indd 27

27/08/2014 12:52

access floor pre-wired service outlet boxes


3 and 4 compartment

CR100

CR122

Dimensions and technical information p. 29


Electrak floor boxes can be supplied pre-wired to power track tap-offs with any variation of sockets, tap-offs, depth or other configuration
Pack

Cat. Nos.

3 compartment pre-wired boxes with 1 x TSSO

Pack

100 mm compartment widths


1
1
1
1
1
1

Single base 85 mm depth, pre-wired with :


CR100 3 m Electrak 24 standard tap-off Cat. No. DP1332
CR101 5 m Electrak 24 standard tap-off Cat. No. DP1532
CR110 3 m Electrak 25 low noise / clean earth tap-off
Cat. No. JP2332
CR111 5 m Electrak 25 low noise / clean earth tap-off
Cat. No. JP2532
CR104 3 m Electrak 28 auxiliary earth tap-off
Cat. No. YP5332
CR105 5 m Electrak 28 auxiliary earth tap-off
Cat. No. YP5532

1
1
1
1
1
1

1
1
1
1
1

Single base 85 mm depth, pre-wired with :


CR120 3 m Electrak 24 standard tap-off Cat. No. DP1332
CR121 5 m Electrak 24 standard tap-off Cat. No. DP1532
CR130 3 m Electrak 25 low noise / clean earth tap-off
Cat. No. JP2332
CR131 5 m Electrak 25 low noise / clean earth tap-off
Cat. No. JP2532
CR124 3 m Electrak 28 auxiliary earth tap-off Cat. No. YP5332
CR125 5 m Electrak 28 auxiliary earth tap-off Cat. No. YP5532

4 compartment pre-wired boxes with 2 x TSSO


75 mm compartment widths

100 mm compartment widths


Single base 85 mm depth, pre-wired with :
CR102 3 m Electrak 24 standard tap-off Cat. No. DP1332
CR103 5 m Electrak 24 standard tap-off Cat. No. DP1532
CR112 3 m Electrak 25 low noise / clean earth tap-off
Cat. No. JP2332
CR113 5 m Electrak 25 low noise / clean earth tap-off
Cat. No. JP2532
CR106 3 m Electrak 28 auxiliary earth tap-off
Cat. No. YP5332
CR107 5 m Electrak 28 auxiliary earth tap-off
Cat. No. YP5532

4 compartment pre-wired boxes with 1 x TSSO


75 mm compartment widths

3 compartment pre-wired boxes with 2 x TSSO

Cat. Nos.

1
1
1
1
1
1

Single base 85 mm depth, pre-wired with :


CR122 3 m Electrak 24 standard tap-off Cat. No. DP1332
CR123 5 m Electrak 24 standard tap-off Cat. No. DP1532
CR132 3 m Electrak 25 low noise / clean earth tap-off
Cat. No. JP2332
CR133 5 m Electrak 25 low noise / clean earth tap-off
Cat. No. JP2532
CR126 3 m Electrak 28 auxiliary earth tap-off Cat. No. YP5332
CR127 5 m Electrak 28 auxiliary earth tap-off Cat. No. YP5532

Pre-wired floor boxes can be supplied with RCD rather than standard
sockets. Add an R to the end of the part numbers for an RCD version.
For example CR100R is a 3 compartment floor box with a twin RCD
socket and a DP1332 tap-off

Also available :
- pre-wired boxes with fused tap-offs
- shallow or deep versions
- separate compartment bases
contact us on +44 (0) 845 600 6266

28

028_Electrak 2014 v1.indd 28

27/08/2014 12:53

access floor service outlet boxes

access floor service outlet boxes

with RCD protection

technical information
n Floor boxes
Dimensions
Lid can accommodate carpets up to 6 mm depth
Accessory plates are 172 mm long, with 162 mm fixing centres
Materials
Lid and trim mouldings are precision engineered from hard wearing
durable ABS. Lid is reinforced with a galvanised mild steel plate
Mounting frame and box base 09 mm thick galvanised steel
Floor service unit conforms to IEC-61534-22
Wiring
Each compartment has 2 entries for 20 mm and 2 entries for 25 mm
flexible conduits
Colour
Grey mouldings. Alternative colours available to special order
Goosewing grey plates

CR4401

Selection charts p. 24-25


Dimensions and technical information (opposite)

Dimensions from top of floor tile into floor void

Electrak floor boxes are available with various RCD protection options
and can be supplied pre-wired to power track tap-offs
C
Pack

Cat. Nos.

Floor boxes with RCD protection and


2 x TSSO

A
B

Boxes contain 1 spare 75 mm width compartment


1
1

1
1
1
1

CR4400 Includes standard sockets


CR4401 Includes low noise sockets

CR4402
CR4403
CR4412
CR4413

Pre-wired RCD protected floor boxes

(mm)

B
Accessory
box depth
(mm)

Boxes contain RCD and 2 x TSSO with


1 spare 75 mm compartment

75
85
110

35
45
45

Pre-wired
Pre-wired
Pre-wired
Pre-wired

with
with
with
with

Cat.
Cat.
Cat.
Cat.

No.
No.
No.
No.

DP1332 tap-off
DP1532 tap-off
JP2332 tap-off
JP2532 tap-off

C
Underside lid to top of
accessory (plug clearance)
(mm)

35
35
60

n To install box
Cut hole in raised floor tile, lower
complete box into aperture and push
firmly down

Floor tile cut-out dimensions


2 compartment : 263 mm x 203 mm1
3 and 4 compartment : 340 mm x 203 mm1
Floor cut-out aperture is the same for single base or separate
compartment base
To fit carpet :
Detach lid and trim assembly by lifting
the blue locking handles and lifting out.
Cut and fit carpet. Push lid and trim
assembly back into place

1 : The aperture dimension 203 mm has a fixing tolerance between 203 to 205 mm

29

029_Electrak 2014 v1.indd 29

27/08/2014 12:54

Floor
grommets...
perfectly balancing
capacity and size
ACCESS GROMMETS
The Electrak range of simple to install access grommets
allow cables and conduit to link between underloor
power and desk power systems
Ranging from 144mm to 232mm in diameter
169mm diameter grommet can accommodate up to 3 x
32mm conduits - perfectly balancing capacity and size
Push-it lid with optional screw ixing to prevent
unauthorised access

30

Removable inlay for optional


carpet fitting

Cable flap allows


permanent connection
of services

Flat mounted RCD socket

NEW 169mm diameter


provides the perfect balance
between size and capacity

Spring loaded screws for rapid


installation

Available pre-wired to power


track tap-offs

POWER AND DATA GROMMETS


The Electrak range of cleaners grommets are the latest
addition to its power and data grommets range. Within
their 169mm diameter, the grommet can house a lat
RCD socket and provide ample space for the user to plug
in or unplug equipment.
Cleaners grommet with lat mounted RCD socket
or standard socket options
Push-it lid with cable lap feature
Spring loaded screws for rapid installation
Available pre-wired to power track tap-offs

UNDERFLOOR TO WORKSTATION
WWW.LEGRAND.CO.UK/ELECTRAK

SYSTEM GUIDE

31

floor grommets
access / power and data

EG0030

EG0010

EG0040

EG0045

Dimensions and technical information p. 33


Pack

Cat. Nos.

Plastic access grommets

Pack

Cat. Nos.

169 mm cut-out size 152 mm

Quick fit installation


Precision engineered from hard wearing durable ABS
Grey mouldings. Other colours available to special
order
Grommets conform to IEC-61534-22
Simply secured by pushing down the spring-loaded
screws and rotating a quarter turn
1

EG0010 144 mm cut-out size 127 mm


Can accomodate all cable types or three metal
conduits up to a 20 mm or 25 mm without foam

EG0030 169 mm cut-out size 152 mm


Allows power, data and flexible conduit up to 32 mm
to pass through raised access floor
Lid can be locked with screw (included)
Maximum number of conduits :
9 x 20 mm
5 x 25 mm
3 x 32 mm

EG0055 232 mm cut-out size 215 mm


High capacity grommet
Recommended for installation in light traffic areas

Plastic power and data grommets


Quick fit installation
Precision engineered from hard wearing durable ABS
Grey mouldings. Other colours available to special
order. Conform to IEC-61534-22
Removable carpet recess
Cable flap feature so grommet lid can be closed
while in use
Simply secured by pushing down the spring loaded
screws and rotating a quarter turn

EG0040 13 A power grommet


Supplied complete with
13 A unswitched socket

EG0045 RCD power grommet


Supplied complete with 13 A RCD socket

EG0051 13 A power/data grommet


Supplied complete with 13 A socket and
1 x 37 x 22 mm cut-out

EG0052 Data grommet


Supplied complete with data plate
2 x 37 x 22 mm cut-out

Pre-wired power grommets


Aluminium access grommet
Body cast aluminium
Lid injection moulded plastic Nylon 66 with
neoprene cable gasket
Secured by quarter-turn fasteners
Floor depth 25 to 55 mm
Access grommet depth 60 mm
(95 mm when back box included)
1

EG0015 144 mm cut-out size 127 mm


Allows power, data and flexible
conduit up to 25 mm to pass
through raised access floor

169 mm cut-out size 152 mm


1
1
1
1

EG0041
EG0042
EG0043
EG0044

Cleaners socket version


DP1332 - 3 m unfused
DP1532 - 5 m unfused
DP1313 - 3 m 13 A fused
DP1513 - 5 m 13 A fused

1
1
1
1

EG0046
EG0047
EG0048
EG0049

RCD socket version


DP1332 - 3 m unfused
DP1532 - 5 m unfused
DP1313 - 3 m 13 A fused
DP1513 - 5 m 13 A fused

Aluminium power grommet


1

EG0025 13 A power grommet


Supplied complete with 13 A
unswitched socket

32

032_Electrak 2014 v2.indd 32

27/08/2014 12:55

floor grommets
technical information
n 144 mm plastic floor grommet

n To install plastic floor grommet

Dimensions

Lift handle and pull to


remove lid

Push grommet into raised floor tile aperture


Push down spring loaded screws and rotate quarter turn
to secure
Ensure wings are located under floor panel
For honeycombed floor panels one wing should face
downwards and one wing should face upwards

Cable access
insert
Drop cable access insert into
housing opening

Slide lid into lug holes

(1) Push down lid to close


(2) If grommet is not in use,
replace cable access insert

144 mm grommet
EG0010

144 mm

55 mm

Recommended hole
cutter is a 5"/127 mm
hole saw blade

125 mm min
127 mm min

Wing

Floor panel cut-out diameter

n 169 mm plastic floor grommets


Access grommet

55

Cat. No. EG0030

148
169

102

Power grommet

148

n 144 mm aluminium grommets

169

Recommended hole cutter is a 6/152 mm hole saw blade

Access grommet

n 232 mm plastic floor grommet

Cat. No. EG0015


60

Dimensions
Large quick fit grommet
Cat. No. EG0055

232 mm
90

58 mm

13 A power grommet
Cat. No. EG0025

213 mm min
215 mm max

60
40
95

Floor panel cut-out diameter


Recommended hole cutter is a
adjustable hole saw blade with
range of 40 mm - 300 mm

144

Recommended hole cutter is a 5/127 mm hole saw blade

All dimensions (mm) are nominal

33

033_Electrak 2014 v4.indd 33

27/08/2014 12:56

34

Intersoc-R ... fast,


reliable, adaptable
modular desk power
TM

COMPLETE SOLUTIONS FOR DEMANDING ENVIRONMENTS


Intersoc-R is a modular desk power system designed to
meet the demands of modern workplaces for faster and more
adaptable solutions.
Designed with speed of installation and lexibility in mind,
Intersoc-Rs modular coniguration enables thousands of
different combinations to be made - providing solutions for every
installation requirement.
Modular system - rapid coniguration and easy workstation
relocation
Push-it connection - modules can simply be disconnected
and additional modules inserted
Busbar interconnection - no need for wiring
Easily adapted to meet the changing demands of the workplace

UNDERFLOOR TO WORKSTATION
WWW.LEGRAND.CO.UK/ELECTRAK

SYSTEM GUIDE

35

The next generation


of power distribution

Available in standard and clean earth versions, with ixed


or rotatable socket options and a safe shuttered electrical
connection, Intersoc-R is the next generation of power
distribution...
Simple push-it, module connection with auto-lock mechanism
creates robust joints and makes installation quicker and easier
32 A system with safe shuttered electrical connections for
additional safety, meets the requirements of BS 7671 : 2008
(including section 543.7)
MCB, RCD and RCBO modules, with reversible hinged covers,
provide a full range of circuit protection options
2, 3 or 4 gang British standard socket modules with ixed or
rotatable, fused or unfused (BS 6396) sockets options - all the
options you need to meet the requirements of any installation
8 international socket options make Intersoc-R ideal for
installations across the globe
Outgoing connections: lexible interlink or end cap with ST
or GST options

NEW Intersoc On-desk


Personal power and data system
Find out more on page 46

36

UNDERFLOOR TO WORKSTATION
WWW.LEGRAND.CO.UK/ELECTRAK

SYSTEM GUIDE

Intersoc-RTM desk modules


electrical supply

IAB301A

IAB002A
IAB660B
IAB312A

IAB610BB

Dimensions and technical information p. 42-45


Intersoc-R features fast modular connection with push-fit auto lock mechanism, safe shuttered electrical connections and a robustly designed rigid
joint between modules. Available in standard and clean earth versions
Independently approved by Intertek. Complies with BS 5733 and the relevant parts of BS 1363 part 2. Manufactured in an approved
ISO 9001 : 2008 facility. Meets the requirements of BS 7671 : 2008 for high integrity earthing (section 5437)
Pack

Cat. Nos.

1
1
1
1

IAB311A
IAB312A
IAB315A
IAB316A

32 A pre-wired feed modules

Pack

Standard earth tap-offs (E24 - White tap-off)


3 m unfused metal tap-off Cat. No. DP1332
5 m unfused metal tap-off Cat. No. DP1532
3 m 13 A fused 5437 metal tap-off Cat. No. DP1327
5 m 13 A fused 5437 metal tap-off Cat. No. DP1527
Low noise / clean earth tap-offs
(E25 - Green tap-off)
1
1
1
1

IAC311A
IAC312A
IAC315A
IAC316A

3 m unfused metal tap-off Cat. No. JP2332


5 m unfused metal tap-off Cat. No. JP2532
3 m 13 A fused 5437 metal tap-off Cat. No. JP2327
5 m 13 A fused 5437 metal tap-off Cat. No. JP2527
Auxiliary earth tap-offs (E28 - Red tap-off)

1
1
1
1

IAF311A
IAF312A
IAF315A
IAF316A

1
1

IAB002A With 2 m 15 mm2 cable


IAB003A With 3 m 15 mm2 cable
IAB005A With 5 m 15 mm2 cable

IAB201A Rewirable feed module (for cable)

16 A feed units with in-built GST


connector
1
1

IAB660B Compact feed module with male GST connector


IAB201B Feed module with male GST and earth bond lead

16 A pre-wired connection leads


13 A fused plug pre-wired to GST connector
1
1
1

IAB301A Standard earth (for flexible conduit)


IAC301A Low noise (for flexible conduit)

32 A feed units with in-built Neutrik


connectors

16 A feed modules pre-wired to 13 A fused


plug

16 A rewirable feed modules

3 m unfused metal tap-off Cat. No. YP5332


5 m unfused metal tap-off Cat. No. YP5532
3 m 13 A fused 5437 metal tap-off Cat. No. YP5327
5 m 13 A fused 5437 metal tap-off Cat. No. YP5527

32 A re-wirable feed modules


1
1

1
1
1

Cat. Nos.

IAB002B With 2 m 15 mm2 cable


IAB003B With 3 m 15 mm2 cable
IAB005B With 5 m 15 mm2 cable
GST to GST connection leads

1
1
1

IAB610BB 1 m length
IAB620BB 2 m length
IAB630BB 3 m length

IAB301E Standard earth


IAC301E Low noise

32 A tap-offs pre-wired to Neutrik connectors


Standard earth tap-offs (E24)
1
1
1
1

IAB311E
IAB312E
IAB315E
IAB316E

1
1
1
1

IAC311E
IAC312E
IAC315E
IAC316E

3 m unfused metal tap-off Cat. No. DP1332


5 m unfused metal tap-off Cat. No. DP1532
3 m 13 A fused 5437 metal tap-off Cat. No. DP1327
5 m 13 A fused 5437 metal tap-off Cat. No. DP1527
Low noise / clean earth tap-offs (E25)
3 m unfused metal tap-off Cat. No. JP2332
5 m unfused metal tap-off Cat. No. JP2532
3 m 13 A fused 5437 metal tap-off Cat. No. JP2327
5 m 13 A fused 5437 metal tap-off Cat. No. JP2527

38

038_039_Electrak 2014 v2.indd 38

27/08/2014 12:56

Intersoc-RTM desk modules


protection, BS sockets, end caps and interlinks

IAC502R

IAB402A

IAB533F

IAB450A

IAZ001A

IAB703A

IAB600B

IAB610B

IAB504R

Dimensions and technical information p. 42-45


The BS version is available with fixed or rotatable sockets. Individually fused sockets are available to meet the requirements of BS 6396 : 2008
(5 x 20 mm anti-surge ceramic fuses)
A wide range of interconnection solutions are available. When 16 A cabling interconnection is used with 32 A under desk solutions, suitable de-rating
protection devices must be incorporated to protect the cables
All protection and switching modules, end caps and interlinks are universally compatible with standard and clean earth / low noise systems
Pack

Cat. Nos.

1
1
1
1
1
1
1
1
1
1
1
1

IAB401A
IAB402A
IAB403A
IAB404A
IAB405A
IAB408A
IAB420A
IAB430A
IAB440A
IAB450A
IAB460A
IAB470A

Protection and switching modules


With 13 A fuse
With 13 A fuse and sw/neon
With 13 A fuse and neon
32 A max. single isolation module
With 30 mA RCD
With neon indicator
With 16 A MCB
With 20 A MCB
With 32 A MCB
With 16 A RCBO
With 20 A RCBO
With 32 A RCBO

Pack

Cat. Nos.

3 gang unfused
1
1

IAC503F Fixed sockets


IAC503R Rotatable sockets

1
1

IAC533F 315 A fixed sockets


IAC533R 315 A rotatable sockets

1
1

IAC504F Fixed sockets


IAC504R Rotatable sockets

1
1

IAC534F 315 A fixed sockets


IAC534R 315 A rotatable

IAZ001A Blank end cap

3 gang individually fused

4 gang unfused

Socket modules standard (grey sockets)


2 gang unfused
1
1

IAB502F Fixed sockets


IAB502R Rotatable sockets

4 gang individually fused

End cap

2 gang individually fused


1
1

IAB532F 315 A fixed sockets


IAB532R 315 A rotatable sockets

Intersoc to intersoc pre-wired interconnection

3 gang unfused
1
1

IAB503F Fixed sockets


IAB503R Rotatable sockets
3 gang individually fused

1
1

IAB533F 315 A fixed sockets


IAB533R 315 A rotatable sockets

1
1

IAB504F Fixed sockets


IAB504R Rotatable sockets

1
1

IAB534F 315 A fixed sockets


IAB534R 315 A rotatable sockets

4 gang unfused

4 gang individually fused

16 A
1
1
1
1
1
1

IAB603A
IAB605A
IAB610A
IAB620A
IAB630A
IAB650A

1
1
1
1
1
1

IAB703A
IAB705A
IAB710A
IAB720A
IAB730A
IAB750A

Without flex
1
1

IAB600B End cap with female GST connector


IAB600C End cap with female ST connector

1
1
1

IAB610B 1 m length
IAB620B 2 m length
IAB630B 3 m length

With flex to female GST connector

2 gang individually fused


1
1

IAC532F 315 A fixed sockets


IAC532R 315 A rotatable sockets

03 m length
05 m length
1 m length
2 m length
3 m length
5 m length

Power out end caps 16 A

2 gang unfused
IAC502F Fixed sockets
IAC502R Rotatable sockets

03 m length
05 m length
1 m length
2 m length
3 m length
5 m length
32 A

Socket modules low noise / clean earth


(green sockets)
1
1

Socket modules low noise / clean earth


(green sockets) (continued)

39

038_039_Electrak 2014 v2.indd 39

27/08/2014 12:57

Intersoc international range


international socket options

IAB5N4A

IAB5P4A

IAC5P2A

IAF5N2A

Dimensions and technical information p. 42-45


The Intersoc 32 A under-desk range is a complete modular power system. Intersoc offers a wide range of international socket options.
The Intersoc modular system features safe shuttered electrical connections and a robustly designed rigid joint between modules. All modules
connect with single push-fit action and auto lock

Pack

Cat. Nos.

Schuko socket modules

Pack

2 gang grey socket outlets


1
1

IAB5N2A 90 angled sockets


IAB5N2B 45 angled sockets
IAB5N4A 90 angled sockets
IAB5N4B 45 angled sockets

1
1

IAF5N2A 90 angled sockets


IAF5N2B 45 angled sockets

1
1

IAF5N4A 90 angled sockets


IAF5N4B 45 angled sockets

1
1

IAB5P4A 90 angled sockets


IAB5P4B 45 angled sockets

1
1

IAC5P2A 90 angled sockets


IAC5P2B 45 angled sockets

1
1

IAC5P4A 90 angled sockets


IAC5P4B 45 angled sockets

2 gang green socket outlets

4 gang red socket outlets

4 gang green socket outlets

French/Belgium socket modules

15 A South African socket modules

2 gang grey socket outlets


IAB5U2A 90 angled sockets
IAB5U2B 45 angled sockets

1
1

IAB5U4A 90 angled sockets


IAB5U4B 45 angled sockets

1
1

IAF5U2A 90 angled sockets


IAF5U2B 45 angled sockets

1
1

IAF5U4A 90 angled sockets


IAF5U4B 45 angled sockets

IAB5P2A 90 angled sockets


IAB5P2B 45 angled sockets
4 gang grey socket outlets

2 gang red socket outlets

1
1

5 A Indian socket modules


2 gang grey socket outlets

1
1

4 gang grey socket outlets


1
1

Cat. Nos.

2 gang grey socket outlets


1
1

IAB5Q2A 90 angled sockets


IAB5Q2B 45 angled sockets

1
1

IAB5Q4A 90 angled sockets


IAB5Q4B 45 angled sockets

1
1

IAC5Q2A 90 angled sockets


IAC5Q2B 45 angled sockets

1
1

IAC5Q4A 90 angled sockets


IAC5Q4B 45 angled sockets

4 gang grey socket outlets

4 gang grey socket outlets

2 gang red socket outlets

2 gang green socket outlets

4 gang red socket outlets

4 gang green socket outlets

40

040_Electrak 2014 v1.indd 40

27/08/2014 12:57

Intersoc international range


international socket options (continued)

IAB5R4A

IAB5S4A

IAC5R2A

IAC5S2A

Dimensions and technical information p. 42-45


The Intersoc 32 A under-desk range is a complete modular power system. Intersoc offers a wide range of international socket options.
The Intersoc modular system features safe shuttered electrical connections and a robustly designed rigid joint between modules. All modules
connect with single push-fit action and auto lock

Pack

Cat. Nos.

Australian/Chinese socket modules

Pack

2 gang grey socket outlets


1
1

IAB5R2A 90 angled sockets


IAB5R2B 45 angled sockets
IAB5R4A 90 angled sockets
IAB5R4B 45 angled sockets

1
1

IAC5R2A 90 angled sockets


IAC5R2B 45 angled sockets

1
1

IAC5R4A 90 angled sockets


IAC5R4B 45 angled sockets

15 A USA socket modules


2 gang grey socket outlets

1
1

4 gang grey socket outlets


1
1

Cat. Nos.

IAB5S2A 90 angled sockets


IAB5S2B 45 angled sockets
4 gang grey socket outlets

1
1

IAB5S4A 90 angled sockets


IAB5S4B 45 angled sockets

1
1

IAC5S2A 90 angled sockets


IAC5S2B 45 angled sockets

1
1

IAC5S4A 90 angled sockets


IAC5S4B 45 angled sockets

2 gang green socket outlets

2 gang green socket outlets

4 gang green socket outlets

4 gang green socket outlets

20 A USA socket modules


2 gang grey socket outlets
1
1

IAB5T2A 90 angled sockets


IAB5T2B 45 angled sockets

1
1

IAB5T4A 90 angled sockets


IAB5T4B 45 angled sockets

1
1

IAC5T2A 90 angled sockets


IAC5T2B 45 angled sockets

1
1

IAC5T4A 90 angled sockets


IAC5T4B 45 angled sockets

4 gang grey socket outlets

2 gang green socket outlets

4 gang green socket outlets

41

041_Electrak 2014 v1.indd 41

27/08/2014 12:58

Intersoc-RTM desk modules


technical information
n Under-desk dimensions (mm)
Compact and
GST feed unit

Feed unit

75

1105

2 socket module

GST
interconnect
male

Blank
end cap

50

12

3 socket module

60

1565

4 socket module

2145

2725

Fixed
end view

Rotatable
end view
379

32

60

60

1 : Dimensions only apply to BS sockets and not the international range

MCB, RCD protection module 1


60

Protection module

Interconnection

60

1745

1155

50

775

1 : 845 mm depth

All dimensions (mm) are nominal

42

042_045_Electrak 2014 v3.indd 42

27/08/2014 12:59

n Testing and accreditation

n British Standards
BS 6396 : 2008 Electrical Systems in Office Furniture and Educational
Furniture Specification
BS 7671 : 2008 incorporating amendment No. 1 : 2011. Requirements
for Electrical Installation (IET Wiring Regulations 17th Edition)
Electricity at Work Regulations 1989

Independently approved by Intertek


Complies with BS 5733 and relevant parts of BS 1363-2
Manufactured within an approved ISO 9001 : 2008 and
ISO 14001 : 2004 facility
Assessed quality assurance certificate No. 2029

Health & Safety Legislation


Below is a brief outline of the main criteria within the standards :
BS 6396 : 2008 was published with regard to the use of electrical
equipment within general office and educational furniture. This
standard sets out in its scope the use and testing of electrical socket
outlets and associated wiring when used together with a 13 A BS 1363
fused plug for mains supply and makes provision for the routing of
cables through furniture

Electrical test data


Rated current
Rated voltage
Frequency

up to 32 A
250 V ~
50/60 Hz

Conductor resistance at 20C


Fixed
2 socket module
4 socket module

08 m
16 m

For compliance with this standard, socket outlet configurations of up


to 4 outlets should be individually fused at 5 A and up to 6 outlets
individually fused at 315 A
Rotatable
09 m
17 m

The standard requires individual socket fusing (as per the table below)
Total number of
sockets
2, 3 or 4 sockets
5 or 6 sockets

Volt drop
Live and neutral
2 socket module
4 socket module
Protection module

15 m V/A
30 m V/A
40 m V/A

40 m V/A
29 m V/A/m
20 m V/A
11 m V/A/m

Special note should be taken of regulation 5437 within


BS 7671 : 2008 - Earthing requirements for the installation of
equipment having high protective conductor currents
Regulation 5437 has particular importance when there is a
requirement for a quantity of information technology equipment
being supplied from a final circuit in a location where the sum of their
protective currents exceeds 10 mA in normal use. Due to current in
the protective conductor arising from the use of IT equipment, there
is a requirement to provide mechanically protected 4 mm2 conductor
(54371103 (ii)). Intersoc achieves this when wired in accordance
with the installation sheets by providing mechanically protected 5 mm2
protective conductors within the product

20 m V/A
29 m V/A/m
11 m V/A/m

Earth fault loop impedance


2 socket module
4 socket module
Protection module

15 m
30 m
40 m

Material specification
Module housing
Socket outlets
Busbars
Other metalwork

(depending on device)

In-feeds :
16 A
+15 mm2
32 A
+4 mm2
Interconnections :
16 A/32 A
+15 mm2
+4 mm2

Individually fused
at
5A
315 A

Meets the requirements of BS 7671 : 2008 (2011) (17th Edition)


The Health and Safety Executive states that installations which
conform to the standards laid down in BS 7671 : 2008 (2011) are
regarded by the HSE as likely to achieve conformity with the relevant
parts of the Electricity at Work Regulations 1989

(depending on device)

In-feeds :
16 A
+15 mm2
32 A
+4 mm2
Interconnections :
16 A/32 A
+15 mm2
+4 mm2

A note on individual socket fusing BS 6396 Compliance :

20 m
29 m/m
20 m
11 m/m

Heat resistant ABS


polycarbonate
high conductivity copper CW004A (C101)
phosphor bronze CW451K (PB102), CW452K (PB103)
brass CW507L (CZ107), CW508L (CZ108)
high conductivity copper CW004A (C101)1

1 : European grades with nearest British Standard shown in brackets

40 m V/A
29 m/m
11 m/m

Mechanical data
Number of conductors
Busbar conductor cross-sectional area
16 A rewirable in-feed terminal capacity
32 A rewirable in-feed terminal capacity

3
5 mm2
10 mm2
10 mm2

43

042_045_Electrak 2014 v3.indd 43

27/08/2014 13:00

Intersoc-RTM desk modules


installation and configuration
n Installation
To connect and disconnect Intersoc modules
1. Connection / disconnection to be made by a competent person
2. Before connecting modules ensure they are the correct way up and in line
3. Push modules together one at a time
4. Modules self-lock when fully pushed together
5. To disconnect modules slide green latch to unlock module and pull apart
6. Always end module run with blank end cap or interconnect

Module self-locking latch

Underside of
modules shown

To fix modules to surface


1. Insert through all fixing holes no. 8 pozi-pan screw or
M4 bolt to required length
2. Tighten screw / bolt down to mounting surface

Slide green latch

Blank end cap

2 socket module

All dimensions (mm) are nominal

44

042_045_Electrak 2014 v3.indd 44

27/08/2014 13:00

n Product configuration
1. Select the type of distribution system - standard, or low noise / clean earth
2. Select the means of powering the system - cable or power track tap-off
3. Select the type of in-feed module to match the cable capacity - 16 A or 32 A
4. Select the means of protection
5. Select the number of socket modules from the 2, 3 or 4 gang range (individually fused or unfused)
6. Select fixed or rotatable sockets
7. Select the interconnection units if required
8. Finish system with the end cap
(All modules push fit and lock together on-site or can be factory assembled to customer requirement)

iiiiiil

Floor grommet

Tap-off

llllllllllllllllllllllllll
llllllll
lllllllllllllll
Underfloor power track

l l ll ll

lllll
32 A in-feed connected to tap-off and
left underfloor until required

l l ll

llll l

lllllllllllllllll

lllllll

Raised floor

ll l l
ll l l l l

l l ll

l l ll

In-feed and power module push


together and self-lock when fully
pushed home

Tap-off and in-feed pulled through floor


grommet after testing and when required

All dimensions (mm) are nominal

45

042_045_Electrak 2014 v3.indd 45

27/08/2014 13:00

XX

Intersoc on-desk...
power and data for
modern workspaces

The new Electrak Intersoc on-desk range brings power, data


and rapid USB charging capability to the modern workstation.
With its contoured edges, clean lines and stylish aluminium and
mirror white inish, Intersoc on-desk blends in perfectly
with contemporary ofice design schemes and enhances the
functionality of the desk space.

UNDERFLOOR TO WORKSTATION
WWW.LEGRAND.CO.UK/ELECTRAK

SYSTEM GUIDE

47

Intersoc on-desk... del


rapid USB char

The fast pace of modern work practices, combined with the need for instant connectivity
is placing an ever greater reliance on the use of multiple devices, whether it be at our
workstation or whilst were on the move. The new range of Intersoc on-desk modules offers
a convenient answer to the growing demand for user-specific desk power and data access,
no matter what the technology requirements.
RAPID USB CHARGING
With an impressive 3.1 Amp dual charging facility, Intersoc on-desks twin USB modules
offer a high speciication, rapid charge facility that keeps your mobile devices ready should
you need to work on the move. Up to two devices (e.g. tablet and smart phone) can be
simultaneously charged at a faster rate than common, lower output chargers.

SUPERCHARGED
CHARGING
Twin USB charging modules
offer a high specification, rapid
charge facility

48

ivering power, data and


ging to the workstation
HIGH PERFORMANCE DATA
CAT 6A keystone jack modules offer high performance data and are supplied via
cables which neatly feed through the rear of the unit. CAT 6 modules are also
available with simple RJ45 connection at both the front and rear of the unit.
TAILORED TO YOUR REQUIREMENTS
Coniguring Intersoc on-desk modules to your exact requirements couldnt be
simpler. Choose from: lat (horizontal) or angled (vertical) mounted units; select
any combination of power and data, and further enhance functionality with single
or double Euro modules or any device from within Legrands Arteor modular
wiring accessories range.

Putting personal back


into desk power and data...
Intersoc on-desk can be
tailored to the demands of
any workstation.

Left: Power is fed to the Intersoc on-desk unit via a choice of


13 A pre-wired plug, GST connector, or Intersoc-R under-desk
connector
Above left: On-desk units are available in flat mounted (pictured)
and angle mounted versions (data options are not available with
horizontal units)
Above: High specification CAT 6A keystone jacks can be supplied
with performance certificates. Easy to fix brackets are supplied
with protective pads that wont damage the desk
Left hand page: Convenient personal power and data ports for
laptops, with CAT 5 / CAT 6 RJ45 feed neatly nestling to the rear
of the unit, plus dual USB charging facility

UNDERFLOOR TO WORKSTATION
WWW.LEGRAND.CO.UK/ELECTRAK

SYSTEM GUIDE

49

Intersoc on-desk modules

Pre-wired with
3 m ex and
BS 1363 plug

Pre-wired with
15 m ex and
GST connector

Cat. No.

Cat. No.

Cat. No.

Horizontal unit with 2 x sockets individually fused


at 315 A

HA3320AA

HB1320AA

HD1320AA

Horizontal unit with 3 x sockets individually fused


at 315A

HA3330AA

HB1330AA

HD1330AA

Horizontal unit with 4 x sockets individually fused


at 315 A

HA3340AA

HB1340AA

HD1340AA

Vertical unit with 2 x sockets individually fused at


315 A

VA3320AA

VB1320AA

VD1320AA

Vertical unit with 3 x sockets individually fused at


315 A

VA3330AA

VB1330AA

VD1330AA

Vertical unit with 4 x sockets individually fused at


315 A

VA3340AA

VB1340AA

VD1340AA

Vertical unit with 2 x sockets individually fused at


315 A plus 1 x rear pluggable CAT 5 / CAT 6
RJ45 outlet

VA3320AB

VB1320AB

VD1320AB

Vertical unit with 2 x sockets individually fused at


315 A plus 2 x rear pluggable CAT 5 / CAT 6
RJ45 outlets

VA3320AC

VB1320AC

VD1320AC

Vertical unit with 2 x sockets individually fused at


315 A plus 1 x rear pluggable data USB outlet

VA3320AD

VB1320AD

VD1320AD

Vertical unit with 2 x sockets individually fused at


315 A plus 2 x rear pluggable data USB outlets

VA3320AE

VB1320AE

VD1320AE

Vertical unit with 2 x sockets individually fused at


315 A plus 1 x CAT 6A RJ45 outlet with 3 m data
lead

VA3320AF

VB1320AF

VD1320AF

Vertical unit with 2 x sockets individually fused at


315 A plus 2 x CAT 6A RJ45 outlets with 3 m
data leads

VA3320AG

VB1320AG

VD1320AG

Vertical unit with 2 x sockets individually fused at


315 A plus carrier to accept 1 x Euro Module
(25 x 50 mm)

VA3320AK

VB1320AK

VD1320AK

Vertical unit with 2 x sockets individually fused at


315 A plus carrier to accept 2 x Euro Modules
(50 x 50 mm)

VA3320AL

VB1320AL

VD1320AL

Vertical unit with 3 x sockets individually fused at


315 A plus 1 x rear pluggable CAT 5 / CAT 6
RJ45 outlet

VA3330AB

VB1330AB

VD1330AB

Vertical unit with 3 x sockets individually fused at


315 A plus 2 x rear pluggable CAT 5 / CAT 6
RJ45 outlets

VA3330AC

VB1330AC

VD1330AC

Vertical unit with 3 x sockets individually fused at


315 A plus 1 x rear pluggable data USB outlet

VA3330AD

VB1330AD

VD1330AD

Vertical unit with 3 x sockets individually fused at


315 A plus 2 x rear pluggable data USB outlets

VA3330AE

VB1330AE

VD1330AE

Description

Pre-wired with
15 m ex and
Intersoc-R connector

Fixings
Description

Cat. No.

Long desk clamp for mounting horizontal units at on the desk

H010

Adhesive xing strips for mounting horizontal units

H002

Long desk clamp for mounting vertical units at an angle on desk

V010

50

050_051 Electrak 2014 v2.indd 50

27/08/2014 14:51

Intersoc on-desk modules


with twin outlet USB charger (31 A)
Pre-wired with
3 m ex and
BS 1363 plug

Pre-wired with
15 m ex and
GST connector

Cat. No.

Cat. No.

Cat. No.

Horizontal unit with 1 x unfused socket plus twin


outlet USB charger

HA3012AA

HB1012AA

HD1012AA

Horizontal unit with 2 x sockets individually fused


at 315 A plus twin outlet USB charger

HA3322AA

HB1322AA

HD1322AA

Horizontal unit with 3 x sockets individually fused


at 315 A plus twin outlet USB charger

HA3332AA

HB1332AA

HD1332AA

Vertical unit with 1 x unfused socket plus twin


outlet USB charger

VA3012AA

VB1012AA

VD1012AA

Vertical unit with 2 x sockets individually fused at


315 A plus twin outlet USB charger

VA3322AA

VB1322AA

VD1322AA

Vertical unit with 3 x sockets individually fused at


315 A plus twin outlet USB charger

VA3332AA

VB1332AA

VD1332AA

Vertical unit with 1 x unfused socket, twin outlet


USB charger plus 1 x rear pluggable CAT 5 /
CAT 6 RJ45 outlet

VA3012AB

VB1012AB

VD1012AB

Vertical unit with 1 x unfused socket, twin outlet


USB charger plus 2 x rear pluggable CAT 5 /
CAT 6 RJ45 outlets

VA3012AC

VB1012AC

VD1012AC

Vertical unit with 1 x unfused socket, twin outlet


USB charger plus 1 x rear pluggable data
USB outlet

VA3012AD

VB1012AD

VD1012AD

Vertical unit with 1 x unfused socket, twin outlet


USB charger plus 2 x rear pluggable data
USB outlets

VA3012AE

VB1012AE

VD1012AE

Vertical unit with 2 x sockets individually fused at


315 A, twin outlet USB charger plus 1 x rear
pluggable CAT 5 / CAT 6 RJ45 outlet

VA3322AB

VB1322AB

VD1322AB

Vertical unit with 2 x sockets individually fused at


315 A, twin outlet USB charger plus 2 x rear
pluggable CAT 5 / CAT 6 RJ45 outlets

VA3322AC

VB1322AC

VD1322AC

Vertical unit with 2 x sockets individually fused at


315 A, twin outlet USB charger plus 1 x rear
pluggable data USB outlet

VA3322AD

VB1322AD

VD1322AD

Vertical unit with 2 x sockets individually fused at


315 A, twin outlet USB charger plus 2 x rear
pluggable data USB outlets

VA3322AE

VB1322AE

VD1322AE

Vertical unit with 2 x sockets individually fused at


315 A, twin outlet USB charger plus 1 x CAT 6A
RJ45 outlet with 3 m data lead

VA3322AF

VB1322AF

VD1322AF

Vertical unit with 2 x sockets individually fused at


315 A, twin outlet USB charger plus 2 x CAT 6A
RJ45 outlets with 3 m data leads

VA3322AG

VB1322AG

VD1322AG

Vertical unit with 2 x sockets individually fused at


315 A, twin outlet USB charger plus carrier to
accept 1 x Euro Module (25 x 50 mm)

VA3322AK

VB1322AK

VD1322AK

Vertical unit with 2 x sockets individually fused at


315 A, twin outlet USB charger plus double
carrier to accept 2 x Euro Modules (50 x 50 mm)

VA3322AL

VB1322AL

VD1322AL

Description

Pre-wired with
15 m ex and
Intersoc-R connector

Note:
All sockets are individually fused at 315 A and mounted at 45 (except units with a single socket outlet which will be unfused and mounted at 90).
Other options are available to special order. Contact us on +44(0) 845 600 6266
CAT 5 / CAT 6 outlets have a rear facing RJ45 that will accept either CAT 5 or CAT 6 data cabling (no data cabling is included with the product)
CAT 6A outlets are supplied with 3 m pre-wired lead and performance certicate
The twin outlet charging USB can supply 31 A shared between the 2 outlets
The data USB outlets have a short ying lead and type-A receptacle at the rear for USB connection to the PC (no USB cabling is included with the product)
Units supplied with carriers to accept Euro modules will be supplied with apertures at the rear for the passing of data or AV cables

51

050_051 Electrak 2014 v2.indd 51

27/08/2014 14:52

Intersoc on-desk modules


technical information
n On-desk dimensions (mm)
Unit with 2 x sockets

Horizontal units
40
100

130
178

Vertical units
30

0
10

Unit with 2 x sockets plus twin


outlet USB charger
50

Unit with 3 x sockets

185
178

Unit with 2 x sockets plus 1 x CAT 5 /


CAT 6 RJ45 outlet
195
243

Unit with 4 x sockets


1825
2305

260
308

Unit with 2 x sockets plus 2 x CAT 5 /


CAT 6 RJ45 outlets

205
253

All dimensions (mm) are nominal

52

052_053 Electrak 2014 v2.indd 52

27/08/2014 13:01

n On-desk dimensions (mm) (continued)

n Testing and accreditation

Unit with 2 x sockets plus 1 x CAT 6A


RJ45 outlet

Complies with BS 5733 and relevant parts of BS 1363-2


Manufactured within an approved ISO 9001 : 2008 and
ISO 14001 : 2004 facility
205
253

n BS 6396 : 2008
Electrical Systems in Office Furniture and Educational Furniture
Specification

Unit with 2 x sockets plus 2 x CAT 6A


RJ45 outlets

Below is a brief outline of the main criteria within the standard :


BS 6396 : 2008 was published with regard to the use of electrical
equipment within general office and educational furniture. This
standard sets out in its scope the use and testing of electrical socket
outlets and associated wiring when used together with a 13 A BS 1363
fused plug for mains supply and makes provision for the routing of
cables through furniture

260
308

Unit with 2 x sockets plus carrier for


Euro Module (25 x 50 mm)

For compliance with this standard, socket outlet configurations of up


to 4 outlets should be individually fused at 5 A and up to 6 outlets
individually fused at 315 A
A note on individual socket fusing BS 6396 Compliance :
The standard requires individual socket fusing (as per the table below)
Total number of
sockets
2, 3 or 4 sockets
5 or 6 sockets

Individually fused
at
5A
315 A

190
238

Material specification
Unit with 2 x sockets plus carrier for
Euro Modules (50 x 50 mm)

Module housing
Module fascia
Socket outlets
End caps

aluminium
polycarbonate
polycarbonate
flame retardant ABS

USB charger module specification


215
263

Supply voltage (nominal)


Supply current
Power consumption (max.)
Frequency
Output voltage
Output current :
Output power :
Over current protection :
Output connector :
Current per socket :

230 V (AC)
13 mA
03 W
50 Hz
+50 V 025 (DC)
3A
15 W (max.)
38 A (max.)
2 x USB Type A sockets
2 A (max.)

All dimensions (mm) are nominal

53

052_053 Electrak 2014 v2.indd 53

27/08/2014 13:02

Contact details
Quotations and Technical Support:
Legrand Electric Ltd.
Great King Street North,
Birmingham, B19 2LF
Tel: +44 (0) 845 600 6266
Fax: +44 (0) 845 600 6760
E-mail: powersales.uk@legrand.co.uk
Customer Services:
Legrand Electric Ltd.
No. 1 Industrial Estate,
Medomsley Road, Consett,
County Durham, DH8 6SR
Tel: +44 (0) 845 600 6266
Fax: +44 (0) 845 600 6366
E-mail: powersales.uk@legrand.co.uk
Accounts:
Legrand Electric Ltd.
Great King Street North,
Birmingham, B19 2LF
Tel: +44 (0) 870 608 9000
Fax: +44 (0) 870 608 9004

FOLLOW
US AT
www.legrand.co.uk
www.legrand.ie
www.youtube.com/legrandtvuk
www.twitter.com/legranduk

Head office (UK and Ireland):


Legrand Electric Limited
Great King Street North, Birmingham, B19 2LF
Tel: 0870 608 9000 Fax: 0870 608 9004
Website: www.legrand.co.uk

This document is printed on sustainably sourced paper. Please recycle.

The Legrand logo is a registered trademark


of the Legrand group of companies.

Electrak workstation power system guide 08/2014.5K