You are on page 1of 9

E1 Plus Electronic Overload Relay

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

Input(1,2,3 or 8 Bytes)

Input assembly parameter 29 = 110 (Default Value)


E1 PLUS
unused

Average %FLA

%Therm Utilized

Input assembly parameter 29 = 106

E1 PLUS

Input assembly parameter 29 = 100


E1 PLUS
Byte 2 y 3

Byte 0 y 1

Byte 6 y 7

Byte 4 y 5

Input assembly parameter 29 = 51


E1 PLUS

Input assembly parameter 29 = 50


E1 PLUS

E3 Plus Electronic Overload Relay

Input assembly parameter 60 = 100 (Default Value)

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

Input

E3 PLUS
Byte 2 y 3

Byte 0 y 1

Byte 6 y 7

Byte 4 y 5

Input assembly parameter 60 = 111


E3 PLUS
Param A Data (high)

Param A Data (low)

Param A Number (high)

Param A Number

Param B Data (high)

Param B Data (low)

Param B Number (high)

Param B Number

Input assembly parameter 60 = 107

I3

I4

E3 PLUS

Input assembly parameter 60 = 106


E3 PLUS

Input assembly parameter 60 = 51


E3 PLUS

Input assembly parameter 60 = 50


E3 PLUS

SMC-Flex 150 Soft Starter


11

10

AS

12

O1

13

O2

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

Word1:Analog Feedback-Current Pashe(Parameter 1)

SMC FLEX
F

31

Input

PowerFlex 40
Input(4,8,12,16 or 20 Bytes)

4 bytes for Logic Status Word/FeedBack for single drive configuration(Default)


6

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

Plus 4 bytes for each multi-drive enabled in parameter 15

AL

AS

MF

OC

I1

I2

Speed Feedback(Low)

I4

Speed Feedback(High)

I3

POWER FLEX 40

PowerFlex 70/700/700H
Input(Depends on interface and datalinks selected)

4 bytes for Logic Status/FeedBack(8 Bytes if using 20-COMM-D interface and 32bit Ref/Fdbk size
6

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

Plus 4 bytes for each multi-drive enabled in parameter 15/ 2 bytes if using a GK61 interface

AL

LC

Speed Feedback(Low)

Rf

Speed Feedback(High)

AS

POWER FLEX 70/700/700H

PowerFlex 755

AS

AL

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

Input(Depends on interface and datalinks selected)

Byte 6 y 7(Speed FeedBack High)

SR0

SR1

SR2

SR3

SR4

RU

ST

DC

DB

SM

PM

TM

ZS

AT

AL

CL

BF

EO

MO

RE

POWER FLEX 755

Byte 4 y 5(Speed FeedBack Low)

18

17

16

18

17

16

19

20

21

22

23

24

25

26

27

28

29

30

31

Output(1 or 3 Bytes)

FLT

I1

I2

Output assembly parameter 28 = 103 (Default Value)

herm Utilized

FLT

I1

I2

Output assembly parameter 28 = 101

Output assembly parameter 28 = 2

Byte 0 y 1

FLT
FLT

Byte 4 y 5

19

20

21

22

23

24

25

26

27

28

29

30

31

Output

Output assembly parameter 59 = 105 (Default Value on E3 Plus)

Byte 0 y 1

Byte 4 y 5

Output assembly parameter 59 = 103 (Default Value on E3 Standard)

Param A Number (low)


Param B Number (low)

Status Parameter B (high)

NI 0

NI 1

NI 2

NI 3

NI 4

NI 5

NI 6

NI 7

NI 8

NI 9

NI10

NI11

NI12

NI13

NI14

NI15

FLT

I1

I2

Output assembly parameter 59 = 110 (Status Parameter Datalink)

Status Parameter B (low)

FLT

I1

I2

Output assembly parameter 59 = 104

FLT

Output assembly parameter 59 = 101

FLT

Output assembly parameter 59 = 2

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

EN

PA

ST

SP

Output

Output(4,8,12,16 or 20 Bytes)

4 bytes for Logic Command/Reference for single drive configuration(Defa


16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

CD

Speed Ref. (High)

AD

AC

DC

Plus 4 bytes for each multi-drive enabled in parameter 15

Speed Ref. (Low)

Output(Depends on interface and datalinks selected)

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

Speed Ref. (High)

CD

AD

Plus 4 bytes for each datalink enabled(8 bytes if using 20-COMM-D interf

AC

a GK61 interface
5

4 bytes for Logic Command Word/Reference(8 bytes if using 20-COMM-D

DC

d 32bit Ref/Fdbk size)

Speed Ref. (Low)

Speed Ref. (High)

Speed Ref. (High)

16

CS

17

CL

18

RU

19

JO

20

21

22

23

24

25

26

27

28

CD

29

AD

30

AC

eed FeedBack Low)

31

DC

Output(Depends on interface and datalinks selected)

n E3 Plus)
9
8

7
6
5
4
3

OA

10

10

OA

11

11

12

12

FR

13

13

FR

14

14

15

15

OA

OB

FR

RT
RT

FR

OA

n E3 Standard)

Status Parameter A (high)

OA

Reserved

OB

RT

FR

rameter Datalink)

Status Parameter A (low)

OA

OB

FR

104

OA

101

SP

ST

O1

CF

O2

10

11

AE

12

A1

13

A2

14

A3

A4

15

FR

SP

ST

CF

MI

AR

DR

10

11

12

RS

13

14

MD

15

e configuration(Default)

if using 20-COMM-D interface and 32bit Ref/Feedback size)


0
0

SP

SP

1
1

ST

ST

2
2

3
3

CF

UD

CF

MI

LC
6

MA

AT

AR

Speed Ref. (Low)

9
9

10

11
11

10

12
12

DR
DT

RS

13

RS

13

14
14

15

MD

15

ng 20-COMM-D interface and 32 bit datalinks)

Speed Ref. (Low)