display alarm list all

--------------------------------------------------------ALARMID
OUTPUT ALARM_NAME
--------------------------------------------------------0x02210915 YES
Anti-theft authentication of the extended frame fails
0x02220915 YES
Anti-theft authentication of the extended frame
succeeds
0x02310000 YES
The communication between the board and the control
board fails
0x02310018 YES
The board hardware is abnormal
0x0231001d YES
The communication between the extended frame and the
main frame fails
0x02310083 YES
Software fault occurs in board FPGA
0x023100a8 YES
The power input of the local shelf fails
0x023100a9 YES
Data synchronization between the active and standby
control boards is canceled
0x023100be YES
The inner power fault
0x023100ed YES
Board software automatic expansion failure
0x023108ae YES
The dying-gasp of extended frame occurs
0x02310cf0 YES
The pluggable memory is faulty
0x02320000 YES
The communication of the board with the control board
recovers
0x02320018 YES
The board hardware abnormity recovers
0x0232001d YES
The communication of the main frame and the extended
frame recovers
0x02320083 YES
Software fault in board FPGA recovers
0x023200a8 YES
The power input of the local shelf recovers
0x023200a9 YES
Data synchronization between the active and standby
control boards recovers
0x023200be YES
The inner power recovered
0x023200ed YES
Board software automatic expansion success
0x023208ae YES
The dying-gasp of extended frame recovers
0x02320cf0 YES
The pluggable memory recovers
0x02410019 YES
The control board is in the over-temperature protection
mode
0x0241a00d YES
The ambient temperature for the board is too high
0x0241a00e YES
The ambient temperature for the board is too low
0x02420019 YES
The control board quits the over-temperature protection
mode
0x0242a00d YES
The high ambient temperature recovers to the normal
range
0x0242a00e YES
The low ambient temperature recovers to the normal
range
0x0a11a055 YES
The ADSL port activation rate fails to reach the rate
threshold
0x0a12a055 YES
The ADSL port activation rate succeeds in reaching the
rate threshold
0x0a310007 YES
Loss of signal occurs at the E1/T1 port
0x0a310008 YES
Loss of frame alignment occurs at the E1/T1 port
0x0a310009 YES
Receive remote alarm occurs at the E1/T1 port
0x0a31000a YES
Loss of multiframe alignment occurs at the E1/T1 port
0x0a31000b YES
Alarm indication signal occurs at the E1/T1 port
0x0a310012 YES
CRC error occurs at the E1/T1 port
0x0a310019 YES
The ADSL chipset is not available
0x0a310021 YES
The upstream ethernet port connection fails or the
state of it is abnormal
0x0a31002a YES
The temperature of the Ethernet optical port is too
high
0x0a31002c YES
The adaptive clock source fails to be recovered from
the bound service

0x0a310032
0x0a310036

YES
YES

0x0a310038

YES

0x0a310092
0x0a3100fd
0x0a31a0dd
0x0a31a0de
0x0a31a0e2
0x0a31a0e3
0x0a31a0e6

YES
YES
YES
YES
YES
YES
YES

0x0a31a0e7

YES

0x0a31a0e8
0x0a31a0e9

YES
YES

0x0a31a0ea

YES

0x0a31a0eb

YES

0x0a31a0ec

YES

0x0a31a0ed

YES

0x0a31a0ee

YES

0x0a31a0f0

YES

0x0a31a0f1

YES

0x0a320007
0x0a320008
0x0a320009
0x0a32000a
0x0a32000b
0x0a320012
0x0a320019
0x0a320021

YES
YES
YES
YES
YES
YES
YES
YES

0x0a32002a

YES

0x0a32002c
0x0a320032
0x0a320036
0x0a320038

YES
YES
YES
YES

0x0a320092
0x0a3200fd
0x0a32a0dd
0x0a32a0de
0x0a32a0e2
0x0a32a0e3

YES
YES
YES
YES
YES
YES

Port type adaptation fault


Load power of the Power over Ethernet port exceeds the
upper limit
Overcurrent for the power supply of the Power over
Ethernet port
The G.SHDSL chipset is not available
The loss of link (LOL) occurs in the BITS input port
The Ethernet port link status changes from up to down
The optical transceiver is absence
The LOS occurs on the Ethernet optical port
Link between stack ports fails
The TX output power of the Ethernet optical port is
higher than the upper threshold or lower than the lower
threshold
The RX received power of the Ethernet optical port is
higher than the upper threshold or lower than the lower
threshold
The remote device is powered off
The temperature of the Ethernet optical port is higher
than the upper threshold or lower than the lower
threshold
The current of the Ethernet optical port is higher than
the upper threshold or lower than the lower threshold
The voltage of the Ethernet optical port is higher than
the upper threshold or lower than the lower threshold
The current of the thermoelectric cooler on the
Ethernet optical port is higher than the upper threshold
or lower than the lower threshold
The temperature of the optical laser on the Ethernet
port is higher than the upper threshold or lower than the
lower threshold
The wavelength sent by the optical transceiver on the
Ethernet port is higher than the upper threshold or lower
than the lower threshold
The performance statistics value of the ETH port
exceeds the alarm threshold
The performance statistics value of the ETH port
exceeds the warning threshold
Loss of signal(LOS) recover at the E1/T1 port
Loss of frame recover at the E1/T1 port
Remote alarm recover at the E1/T1 port
Loss of multiframe alignment recover at the E1/T1 port
Alarm indication signal recover at the E1/T1 port
CRC recover at the E1/T1 port
The ADSL chipset recovers
The upstream ethernet port connection failure recovers
or the state of it is normal
The temperature of the Ethernet optical port recovers
to the normal range
The adaptive clock source restore
Port type adaptation fault recovery
Load power of the Power over Ethernet port recovers
Overcurrent for the power supply of the Power over
Ethernet port recovers
The G.SHDSL chipset recovers from a fault
The BITS input port recovers from loss of link (LOL)
The Ethernet port link status changes from down to up
The optical transceiver recovers to the normal state
The Ethernet optical port recovers from LOS
Link between stack ports on the boards to be bound

0x0a32a0e6

YES

0x0a32a0e7

YES

0x0a32a0e8
0x0a32a0e9

YES
YES

0x0a32a0ea

YES

0x0a32a0eb

YES

0x0a32a0ec

YES

0x0a32a0ed

YES

0x0a32a0ee

YES

0x0a32a0f0

YES

0x0a32a0f1

YES

0x0c310001
0x0c320001
0x11310020
0x11310023

YES
YES
YES
YES

0x11310025

YES

0x11310027

YES

0x11310028

YES

0x11310029

YES

0x11320020
0x11320023
0x11320025
0x11320027
0x11320028
0x11320029

YES
YES
YES
YES
YES
YES

0x13010001

YES

0x13020001

YES

0x1411000b

YES

0x1411000c

YES

0x1412000b
0x1412000c
0x14310000

YES
YES
YES

0x14310001

YES

0x14310002

YES

0x14310003

YES

returns to a normal status


The TX output power of the Ethernet optical port
returns to the normal range
The RX received power of the Ethernet optical port
returns to the normal range
The remote device is powered on
The temperature of the Ethernet optical port recovers
to the normal range
The current of the Ethernet optical port recovers to
the normal range
The voltage of the Ethernet optical port recovers to
the normal range
The current of the thermoelectric cooler on the
Ethernet optical port recovers to the normal range
The temperature of the optical laser on the Ethernet
port recovers to the normal range
The wavelength sent by the optical transceiver on the
Ethernet port recovers to the normal range
The performance statistics value of the ETH port
recovers to a value lower than the alarm threshold
The performance statistics value of the ETH port
recovers to a value lower than the warning threshold
SPC is disconnected
SPC is recovered
Loss of cell delimitation (LOCD) occurs at the ATM port
Loss of pointer (LOP) occurs at the SDH layer of the
ATM port
The ATM port receives the path alarm indication signals
from the far end
The ATM port receives the path remote defect indication
signals from the far end
Out of frame(OOF) occurs at the SDH layer of the ATM
port
The loss of receiving reference clock occurs at the ATM
port
Loss of cell delimitation (LOCD) recovery
Loss of pointer (LOP) recovery
Path alarm indication signal (PAIS) recovery
Path remote defect indication (PRDI) recovery
Out of frame (OOF) recovery
Loss of receiving reference clock recovery at the ATM
port
Communication between the VAG and the SIP proxy server
is interrupted
Communication between the VAG and the SIP proxy server
recovers
A TDM connection fault occurs between the peer end and
its connected equipment
The TDM connection fault occurs between the local
device and the peer end
The TDM connection AIS recovers from the abnormal state
The TDM connection RDI recovers from the abnormal state
The signal degrades on the line connected to the STM
port
The port receives the remote defect indication signal
of the tributary layer of the peer end
The AIS is abnormal on the line connected to the STM
port
The port receives the remote defect indication signal
of the line of the peer end

0x14310004
0x14310005
0x14310006
0x14310007

YES
YES
YES
YES

0x14310008

YES

0x14320000
0x14320001

YES
YES

0x14320002
0x14320003

YES
YES

0x14320004
0x14320005
0x14320006

YES
YES
YES

0x14320007
0x14320008
0x1531a000
0x1531a24d
0x1532a000
0x1532a24d
0x15411001
0x15411005
0x15411010
0x15411012
0x15411015
0x15411018
0x1541101a
0x1541101b
0x15411020
0x15411027
0x15411100
0x15411101
0x15411102
0x15411103
0x15411104
0x15411105
0x15411106
0x15411108
0x1541110a
0x1541110b
0x1541110c
0x1541110d
0x1541110e
0x1541110f
0x15411110
0x15411111
0x15411112
0x15411113
0x15411114
0x15411115
0x15411201

YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES

0x15411202
0x15411203
0x15411204
0x15411220
0x15411221

YES
YES
YES
NO
NO

The SDH layer frames of the port are lost


The port fails to receive signals
The AIS of the tributary layer is abnormal
A fault occurs between the peer end and its connected
equipment
The connection fault occurs between the local device
and the peer end
The signal degradation recovers
The remote defect indication signal of the tributary
layer recovers from the abnormal state
The AIS of the line recovers from the abnormal state
The remote defect indication signal of the line
recovers from the abnormal state
The frame loss recovers
The port recovers from signal receiving failure
The AIS of the tributary layer recovers from the
abnormal state
The remote AIS recovers from the abnormal state
The remote RDI recovers from the abnormal state
The communication of the EMU with the host is abnormal
Batteries are not detected
The communication of the EMU with the host recovers
Batteries recover
The unnamed analog parameter is abnormal
The unnamed digital parameter is abnormal
The battery will power off
The AC power is off
The battery loop is broken
The load fuse is broken
Battery charging over-current alarm
The battery set is undervoltage
The rectifier module is abnormal
Battery discharging over-current alarm
The AC voltage is out of the normal range
The AC switch is turned off
The battery voltage is out of the normal range
The battery fuse has burned
The load fuse has burned
The rectifier module is abnormal
The DC power is abnormal
The door is opened
Theft alarm
The MDF is abnormal
The fan is abnormal
Fire alarm
Smoke alarm
The water monitor reports an alarm
The diesel is abnormal
The odor monitor reports an alarm
The air-conditioning is abnormal
The lightning arrester is faulty
The DC voltage is abnormal by digital parameter monitor
The output control switch is abnormal
The temperature is out of the normal range by analog
parameter monitor
The humidity is out of the normal range
The DC voltage is out of the normal range
The current is out of the normal range
Power module error
Power module circuit error

0x15411256
0x1541125b
0x1541125d
0x1541125e
0x15411261
0x15411265
0x15411267
0x1541a009
0x1541a00b
0x1541a023
0x1541a024
0x1541a025
0x1541a026

YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES

0x1541a24c
0x15421001

YES
YES

0x15421005

YES

0x15421010
0x15421012
0x15421015
0x15421018
0x1542101a
0x1542101b
0x15421020
0x15421027
0x15421100
0x15421101
0x15421102
0x15421103
0x15421104
0x15421105
0x15421106
0x15421108
0x1542110a
0x1542110b
0x1542110c
0x1542110d
0x1542110e
0x1542110f
0x15421110
0x15421111
0x15421112
0x15421113
0x15421114
0x15421115
0x15421201

YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES

0x15421202
0x15421203
0x15421204
0x15421220
0x15421221
0x15421256
0x1542125b
0x1542125d
0x1542125e
0x15421261
0x15421265

YES
YES
YES
NO
NO
YES
YES
YES
YES
YES
YES

Battery Low-Temperature alarm


Battery 1 Temperature Sensor fault alarm
Environment Humidity Sensor fault alarm
Environment 1 Temperature Sensor fault alarm
Mismatched power module
Battery High-Temperature alarm
Battery over voltage alarm
The AC input voltage is abnormal
The DC voltage is abnormal
An exception occurs in the EMU hardware
The fan is blocked and therefore stops rotation
The temperature is out of the normal range
Two or more than two fans blocked and therefore stops
rotation
Battery Temperature out of normal range
The value of the unnamed analog parameter recovers to
the normal range
The value of the unnamed digital parameter recovers to
the normal range
The battery recovers from power-off
The power supply of the AC recovers
The battery loop recovers
The load fuse recovers
battery charging over-current recovery alarm
The battery set recovers from undervoltage
The rectifier module recovers
battery discharging over-current recovery alarm
The AC voltage recovers to the normal range
The AC switch recovers
The battery voltage recovers
The battery fuse recovers
The load fuse recovers
The rectifier module recovers from a fault
The DC recovers
The door is closed
The theft alarm is cleared
The MDF recovers
The fan recovers
The fire alarm is cleared
The smoke alarm is cleared
The water alarm is cleared
The diesel recovers
The odor alarm is cleared
The air-conditioning recovers
The lightning arrestor recovers from a fault
The DC voltage recovers
The output control switch recovers
The temperature recovers to the normal range by analog
parameter monitor
The humidity recovers to the normal range
The DC voltage recovers to the normal range
The current recovers to the normal range
Power module recovered
Power module circuit recovered
Battery Low-Temperature recovery alarm
Battery 1 Temperature Sensor recovers
Environment Humidity Sensor recovers
Environment 1 Temperature Sensor recovers
Power module recovers
Battery High-Temperature recovery alarm

0x15421267
0x1542a009
0x1542a00b
0x1542a023
0x1542a024
0x1542a025
0x1542a026
0x1542a24c
0x17310007
0x17320007
0x1a010001
0x1a020001
0x1e010008
0x1e020008
0x28110039

YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES

0x28110049

NO

0x28120039

YES

0x28120049

NO

0x29110001
0x29110002
0x29110004
0x29120001
0x29120002
0x29120004
0x2d31a001

YES
YES
YES
YES
YES
YES
YES

0x2d31a005

YES

0x2d31a006
0x2d31a007
0x2d31a009
0x2d31a00a
0x2d31a00b
0x2d31a00c
0x2d32a001

YES
YES
YES
YES
YES
NO
YES

0x2d32a005

YES

0x2d32a006
0x2d32a007
0x2d32a009
0x2d32a00a

YES
YES
YES
YES

0x2d32a00b
0x2d32a00c
0x2e111999
0x2e112001
0x2e112002
0x2e112003
0x2e112004
0x2e112006
0x2e112007

YES
NO
YES
YES
YES
YES
YES
YES
YES

0x2e112008
0x2e112009

YES
YES

Battery over voltage recovery alarm


The AC input voltage recovers
The DC output voltage recovers
An exception occurs in the EMU hardware recovers
The fan blocking recovers
The temperature recovers to the normal range
The critical multi-fan blocking recovers
Battery Temperature recovery alarm
The MELT chip is faulty
The MELT chip recovers
H.248 interface interruption
H.248 interface recovery
L2UA link set is deactivated
L2UA link set is activated
The number of occupied IP neighbor hardware entries
exceeds the upper threshold
The number of occupied IP route hardware entries
exceeds the upper threshold
The number of occupied IP neighbor hardware entries is
restored to the permitted range
The number of occupied IP route hardware entries is
restored to the permitted range
The ring topology in the subscriber port is found
The ring topology in the PON port is found
The ring topology in the PON port is found
The ring topology in the subscriber port is cleared
The ring topology in the PON port is cleared
The ring topology in the PON port is cleared
The input signal of the one external clock source is
lost
The input signal of the 1588 external clock source is
lost
Clock is not in tracing mode
Loss of ESMC
The 1588 clock source fails to be locked
The asymmetry measure value is too large
The input QL of the clock source fails
Output of the external clock is closed
The input signal of the one external clock source
recovers
The input signal of the external 1588 clock source
recovers
Clock is in tracing mode
Loss of ESMC recovers
The 1588 clock source recovers to the locked state
The asymmetry measure value recovers to the normal
range
The input QL of the clock source recovers
Output of the external clock is opened
The ONT initiative to go offline
The RDIi occurs
The loss of GEM channel delineation (LCDGi) occurs
The signal degrade of ONTi (SDi) occurs
The signal fail of ONTi (SFi) occurs
The loss of frame of ONTi (LOFi) occurs
The distribute fiber is broken or the OLT cannot
receive expected optical signals from the ONT(LOSi/LOBi)
The ONT works in emergency channel mode
The statistics of GPON ONT FEC downstream correctable
code words exceed alarm threshold

0x2e11200a

YES

0x2e1130ff

NO

0x2e11999a

YES

0x2e11999c
0x2e11999e
0x2e11999f
0x2e11a001

YES
YES
YES
YES

0x2e11a002
0x2e11a009
0x2e11a00a

YES
YES
YES

0x2e11a00b
0x2e11a00c
0x2e11a00f
0x2e11a104
0x2e11a107
0x2e11a523

YES
YES
YES
YES
YES
YES

0x2e11a524
0x2e121999
0x2e122001
0x2e122002
0x2e122003
0x2e122004
0x2e122006
0x2e122007

YES
YES
YES
YES
YES
YES
YES
YES

0x2e122008
0x2e122009

YES
YES

0x2e12200a

YES

0x2e1230ff
0x2e12999a

NO
YES

0x2e12999c
0x2e12999e
0x2e12999f
0x2e12a001

YES
YES
YES
YES

0x2e12a002

YES

0x2e12a009
0x2e12a00a

YES
YES

0x2e12a00b
0x2e12a00c

YES
YES

0x2e12a00f
0x2e12a104

YES
YES

0x2e12a107
0x2e12a523

YES
YES

The statistics of GPON ONT FEC downstream uncorrectable


code words exceed alarm threshold
A DoS attack caused by ONT management messages occurs
on the PON port
The active/standby status of the protection group
member is different from that of the remote device
One or more ONTs under this port failed in ranging
The downstream signal degrade (SD) of the ONT occurs
The downstream signal fail (SF) of the ONT occurs
The feeder fiber is broken or OLT can not receive any
expected optical signals(LOS)
The hardware of the GPON port is faulty
The deactivation failure of ONTi (DFi) occurs
The loss of acknowledgement PLOAM message with ONTi (
LOAi) occurs
The dying-gasp of GPON ONTi (DGi) is generated
The loss of PLOAM of ONTi occurs(LOAMi/LOPCi)
The physical equipment error of ONTi (PEEi) occurs
The number of ONT LOOCis exceeds the alarm threshold
The status of ONT's E1/T1 port is abnormal
The backbone fiber on the port in Type B protection
group is broken or the expected optical signal is not
detected
The number of ONT DOWis exceeds the alarm threshold
The ONT initiative to go offline recovers
The RDIi recovers
The loss of GEM channel delineation (LCDGi) recovers
The signal degrade of ONTi (SDi) recovers
The signal fail of ONTi (SFi) recovers
The loss of frame of ONTi (LOFi) recovers
OLT can receive expected optical signals from ONT(LOSi/
LOBi recovers)
The working mode of the ONT recovers
The statistics of GPON ONT FEC downstream correctable
code words return to the range within the threshold
The statistics of GPON ONT FEC downstream uncorrectable
code words return to the range within the threshold
The ONT stops the DoS attack on management messages
The active/standby status of the protection group
member returns to be the same as that of the remote
device
No ONT under this port failed in ranging
The downstream signal degrade (SD) of the ONT recovers
The downstream signal fail (SF) of the ONT recovers
OLT can receive expected optical signals from ONTs(LOS
recovers)
The optical transceiver hardware of the GPON port
recovers from fault
The deactivation failure of ONTi (DFi) recovers
The loss of acknowledgement PLOAM message with ONTi (
LOAi) recovers
The dying-gasp of GPON ONTi (DGi) recovers
The loss of PLOAM of ONTi recovers(LOAMi/LOPCi
recovers)
The physical equipment error of ONTi (PEEi) recovers
The number of ONT LOOCis reduces to the restore
threshold
The status of ONT's E1/T1 port recovers
The port in Type B protection group receives the
expected optical signal

0x2e12a524

YES

0x2e21a102
0x2e21a103
0x2e22a102
0x2e22a103
0x2e313015
0x2e313016
0x2e313017
0x2e313018
0x2e313019

YES
YES
YES
YES
YES
YES
YES
YES
YES

0x2e31301a
0x2e313024

YES
YES

0x2e313025
0x2e31302a
0x2e31305c

YES
YES
YES

0x2e31305e

YES

0x2e31305f

YES

0x2e313060

YES

0x2e313062

YES

0x2e314020
0x2e314021

YES
YES

0x2e314022
0x2e31999b
0x2e31999d
0x2e31a01b
0x2e31a034
0x2e323015
0x2e323016
0x2e323017
0x2e323018
0x2e323019
0x2e32301a
0x2e323024

YES
YES
YES
YES
NO
YES
YES
YES
YES
YES
YES
YES

0x2e323025

YES

0x2e32302a

YES

0x2e32305c

YES

0x2e32305e

YES

0x2e32305f

YES

0x2e323060

YES

0x2e323062

YES

0x2e324020

YES

0x2e324021

YES

The number of ONT DOWis reduces to the restore


threshold
The GPON ONT configuration recovery fails
The APS protocol of remote protection group is fault
The GPON ONT configuration recovery is successful
The APS protocol of remote protection group recovers
The hardware of the ONT is faulty
The ONT switches to the standby battery
The standby battery of the ONT is lost
The standby battery of the ONT cannot be charged
The voltage of the standby battery of the ONT is too
low
The shell of the ONT is opened
The loss of signals occurs on the ethernet port of the
ONT
No signal is received in the video UNI of the ONT
The E1/T1 port loss of signal (LOS) occurs at the ONT
Local optical transceiver parameters exceed alarm
threshold
Remote optical transceiver parameters exceed alarm
threshold
Numerous ONTs connected to the PON port are powered off
concurrently
Local optical transceiver parameters exceed warning
threshold
Remote optical transceiver parameters exceed warning
threshold
The optical transceiver of the PON port is absent
There are illegal incursionary rogue ONTs under the
port
The ONT is rogue ONT
The ONT temperature exceeds the alarm threshold
The ONT voltage exceeds the alarm threshold
The xPON MAC chipset is fault
The power consumption of the ONT is overloaded
The ONT recovers from the fault of hardware
The external power supply of the ONT recovers
The ONT recovers from the loss of standby battery
The standby battery of the ONT recovers
The voltage of the standby battery of the ONT recovers
The shell of the ONT is closed
The ethernet port of the ONT recovers from the loss of
signals
The video UNI of the ONT recovers from the loss of
signals
The E1/T1 port of the ONT recovers from loss of signal
(LOS)
Local optical transceiver parameters exceed alarm
threshold recover
Remote optical transceiver parameters exceed alarm
threshold recover
The ONTs which are powered off concurrently start to
recover
Local optical transceiver parameters exceed warning
threshold recover
Remote optical transceiver parameters exceed warning
threshold recover
The optical transceiver of the PON port recovers to the
normal state
The illegal incursionary rogue ONTs under the port have

0x2e324022
0x2e32999b
0x2e32999d
0x2e32a01b
0x2e32a034
0x2f210001
0x2f210002

YES
YES
YES
YES
NO
YES
YES

0x2f210003

YES

0x2f210004

YES

0x2f210005
0x2f210006
0x2f220001

YES
YES
YES

0x2f220002

YES

0x2f220003

YES

0x2f220004

YES

0x2f220005

YES

0x2f220006

YES

0x31210001
0x31220001
0x34010001
0x34020001
0x3641a001
0x3642a001

YES
YES
YES
YES
YES
YES

0x3a010002
0x3a01001c

YES
YES

0x3a010022
0x3a010024
0x3a010025
0x3a020002
0x3a02001c

YES
YES
NO
YES
YES

0x3a020022

YES

0x3a020024

YES

0x3a020025
0x3a310010
0x3a310018
0x3a310028
0x3a320010
0x3a320018
0x3a320028
0x3b010008
0x3b020008
0x3d310008
0x3d310022
0x3d310025
0x3d310028

NO
YES
YES
YES
YES
YES
YES
NO
NO
YES
YES
YES
YES

been cleared
The rogue ONT disappears
The ONT temperature becomes normal
The ONT voltage becomes normal
The xPON MAC chipset recovers from fault
The power supply of the ONT is normal
Loss of Ethernet connectivity check message
Reception of invalid Ethernet connectivity check
message
Reception of Ethernet cross connect connectivity check
message
Reception of Ethernet connectivity check message with
the RDI bit set
At least one remote MEP's interface is not up
Port is deactivated due to Ethernet connectivity fault
Recovery of Ethernet connectivity check message loss
defect
Recovery of invalid Ethernet connectivity check message
defect
Recovery of Ethernet cross connect connectivity check
message defect
Recovery of Ethernet connectivity check message with
RDI defect
Recovery of down interfaces on which all remote MEPs
are configured
Port is activated due to recovery of Ethernet
connectivity fault
The default password for user root is not changed
The default password for user root is changed
MGCP interface interruption
MGCP interface recovery
The system resources usage exceeds the threshold
The system resources usage recovers from the overload
state to the normal state
The physical line of the BRA port fails
The CRC errors on the BRA port reach the alarm
threshold
CRC error count of E1 port reaches the alarm threshold
Line error count of E1 port reaches the alarm threshold
FXO port power fault
Physical line of BRA port recovers
CRC error count of BRA port recovers to normal after
reaching the alarm threshold
CRC error count of E1 port recovers to normal after
reaching the alarm threshold
Line error count of E1 port recovers to normal after
reaching the alarm threshold
FXO port power restore
E1 line abnormal
User line fault
A/B line power abnormal
E1 line normal
User line normal
A/B line power normal
ISDN Layer-2 link abnormal
ISDN Layer-2 link normal
The VDSL chipset is unavailable
Vectoring service on the board fails
The port error sample feedback abnormal
The port pilot sequence is abnormal

0x3d310029
0x3d310030
0x3d310031
0x3d310032

YES
YES
YES
YES

0x3d320008
0x3d320022
0x3d320025
0x3d320028
0x3d320029
0x3d320030
0x3d320031
0x3d320032
0x3f010008
0x3f010009
0x3f01000a
0x3f01000b
0x3f01000c
0x3f01000d
0x3f01000e
0x3f020008
0x3f020009
0x3f02000a
0x3f02000b
0x3f02000c
0x3f02000d

YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES

0x3f02000e

YES

0x3f310000
0x3f320000
0x40010005
0x40020005
0x60010008
0x60020008
0x60110007
0x60110008
0x60112007

YES
YES
YES
YES
YES
YES
YES
YES
YES

0x6011a601

YES

0x6011a602

YES

0x6011a603

YES

0x6011a604

YES

0x60120007
0x60120008
0x60122007

YES
YES
YES

0x6012a601

YES

0x6012a602

YES

0x6012a603

YES

0x6012a604

YES

0x6031000b

YES

The port is activated in non-vectoring mode


Vectoring services in the system fail
The single-wire on the port is disconnected
The port can not be activated by auto reset after
offline
The VDSL chipset recovers from unavailability
Vectoring service on the board recovers
The port error sample feedback recovers
The port pilot sequence recovers
The port is activated in vectoring mode
Vectoring services in the system recover
The single-wire on the port is re-connected
The port is back to active after auto reset
ONT SIP user authenticate fail
ONT SIP user register timeout
ONT SIP user register fail
ONT MG interface fault
A mass of ONT SIP users authenticate fail
A mass of ONT SIP users register timeout
A mass of ONT SIP users register fail
ONT SIP user authenticate success
ONT SIP user register success(timeout recovery)
ONT SIP user register success(Error elimination)
ONT MG interface recovery
A mass of ONT SIP users authenticate success
A mass of ONT SIP users register success(timeout
recovery)
A mass of ONT SIP users register success(Error
elimination)
The SLIC of the POTS service board is locked
The SLIC of the POTS service board is unlocked
The ANCP session is terminated
The ANCP session is established
Ring of ONT Ethernet port is detected
Ring of ONT Ethernet port disappeared
The EPON ONT configuration recovery fails
The quality of the ONT optical path is poor
The distribute fiber is broken or the OLT cannot
receive expected optical signals from the EPON ONT(LOSi)
The performance statistics value of the EPON port
exceeds the alarm threshold
The performance statistics value of the EPON port
exceeds the warning threshold
The performance statistics value of the ONT exceeds the
alarm threshold
The performance statistics value of the ONT exceeds the
warning threshold
The EPON ONT configuration recovery is successful
The quality of the ONT optical path recovers
OLT can receive expected optical signals from EPON ONT(
LOSi recovers)
The performance statistics value of the EPON port
recovers to a value lower than the alarm threshold
The performance statistics value of the EPON port
recovers to a value lower than the warning threshold
The performance statistics value of the ONT recovers to
a value lower than the alarm threshold
The performance statistics value of the ONT recovers to
a value lower than the warning threshold
The optical transceiver of the EPON OLT port is faulty

0x60311011
0x6031a033
0x6031a605

The dying-gasp of EPON ONTi (DGi) occurs


The voltage of ONT's external power is abnormal
The OLT optical module of this port does not support
the ONT NNI type(s) on the port
0x6032000b YES
The optical transceiver state of the port recovers
0x60321011 YES
The dying-gasp of EPON ONTi (DGi) recovers
0x6032a033 YES
The voltage of the external power of the ONT recovers
0x6032a605 YES
The OLT optical module of this port supports the ONT
NNI type(s) on the port
0x64110001 YES
The MAC address occupancy in the system exceeds the
upper threshold
0x64110002 YES
The MAC address occupancy on the board exceeds the
upper threshold
0x64120001 YES
The MAC address occupancy in the system is restored to
the permitted range
0x64120002 YES
The MAC address occupancy on the board is restored to
the permitted range
--------------------------------------------------------CRP-H1(config)#