You are on page 1of 11

Punching Shear Strength Design of RC Slab According ACI318M-08

Project :Building :Element:Location:-

Designed by:Checked by:Date:-

Project
Building
Element
Location

General Input :Flat Slab Input


Slab thk t
cover
d

260

mm

fy

420

N/mm2

25

mm

fc'

30

N/mm2

225

mm

fyt

420

N/mm2

Normal weight concrete = 1


Column Dimensions
c1 Depth

600

mm

c2 Width

400

mm

Edge Column-width

Position

Case C

1.50

ACI 11.11.2.1.a

30

ACI 11.11.2.1.b

Punching Shear Input


Vu

900

Mu1

75

KN.m

Mu2

50

KN.m

KN

a-Calculation of RC punching shear resistance without shear reinforcement (Vn


b1

712.5

mm

b2

bo

2050

mm

ACI 11.11.1.2

Vc = min. of

0.75
0.17(1+2/)
( _ )
0.083 ((_ )/_
+2) ( _ )
0.33
( _ )
= 1.356

625

mm

ACI 9.3.2.3 & ACI 9.3.4.a

= 2.173

N/mm2

ACI 11.11.2.1.a

= 2.406

N/mm2

ACI 11.11.2.1.b

= 1.807

N/mm2

ACI 11.11.2.1.c

N/mm2

b-Calculation of unbalanced moment transferred by eccentricity of shear


_(_1 )=1/(1+(23)
(_1_2 ))

= 0.584

_(_1 )=(1
_(_1))

_
1

= 0.416
###

_(_2 )=1/(1+(23)
(_2_1 ))

_(_2 )=(1
_(_2))

_
2

c-Calculation of total punching stress


_( ) =
0.5( _ )

_ = _/(_ ) +
_(_1 ) _1/
(_1 ) + _(_2 )
_2/
(_2 )
Slab Punching Design,
ACI318-08

Page 1 of 11

= 2.054

N/mm2

= 2.422

N/mm2

= 0.616
= 0.384
1.021E+08

ACI 11.11.5.2.a &b

>
M.A.S

Punching Shear Strength Design of RC Slab According ACI318M-08


Project :Building :Element:Location:-) +
_ = _/(_

Project
Building
Element
Location

_(_1 ) _1/
(_1 ) + _(_2 )
_2/(_2 )

Slab Punching Design, ACI318-08

Designed by:Checked by:Date:-

>

Page 2 of 11

M.A.S

Punching Shear Strength Design of RC Slab According ACI318M-08


Project :Building :Element:Location:-

Designed by:Checked by:Date:-

Project
Building
Element
Location

d-Calculation of Shear RFT.


vs

N/A

N/mm2 ,ACI 11.11.7.2.b

Sstirrup

100

mm

Av

N/A

mm2

nstirrup branch

12

Av/stirrup leg

N/A

mm2/side/leg

Av bar act

N/A

mm2

a distance

N/A

mm

Slab Punching Design, ACI318-08

OK
Stirrup Dia.

_( ) =
0.66( _ )
10

Smax

mm

Total number of branches distributed on all sides

Distance that stirrups shall be extended to it, from the

Page 3 of 11

M.A.S

Punching Shear Strength Design of RC Slab According ACI318M-08


Project :Building :Element:Location:-

Slab Punching Design, ACI318-08

Project
Building
Element

Designed by:Checked by:Date:-

Location

Page 4 of 11

M.A.S

rev 1.1

M. Abu Shady
M. Abu Shady
12-Aug-16

without shear reinforcement (Vn = Vc)


bo substracted

mm

ACI 13.5.3.2
ACI 11.11.7.1
PCA NOTES ON ACI318-08, Fig. 16-13

ACI 11.11.5.2.a &b

vn max, Use Drop Panel

Slab Punching Design, ACI318-08

Page 5 of 11

M.A.S

rev 1.1

M. Abu Shady
M. Abu Shady
12-Aug-16

Vc , Use Drop Panel

Slab Punching Design, ACI318-08

Page 6 of 11

M.A.S

rev 1.1

M. Abu Shady
M. Abu Shady
12-Aug-16

= 3.615 N/mm2 ,ACI 11.4.7.9


= 112.5 mm, ACI 11.11.3.3
No. sides

=3

that stirrups shall be extended to it, from the column face in each side

Slab Punching Design, ACI318-08

Page 7 of 11

M.A.S

rev 1.1

M. Abu Shady
M. Abu Shady
12-Aug-16

Slab Punching Design, ACI318-08

Page 8 of 11

M.A.S

DIA (mm)
6
8
10
12
14
16
18
20
22
25
32

Area (mm2)
29
51
79
114
154
201
255
314
380
491
804

Case
E
G

For Seismic Cases


For Non-seismic Cases

Yes
No
External_Calc.
No.

rev1.0
Date:
6-Nov-14
1- correcting the calculation of cell E30, it was a constant value in pervious rev.
it is now calculating the value of 0.17*(1+2/)*SQRT(fc) correctly.
2- All cells equations now are visible even if the sheet is password protected.
3- Modifiying the shear rft. Calculations.
4- adding vs max= shear*0.66*SQRT(fc) in cell i42 and compare it with vs calculated, as noted

th vs calculated, as noted by "Eng. Mohamed elsawaf" feedback

You might also like