MEGATECH DESIGNERS CONSULTANTS INT'L Confidential

BASE PLATE DESIGN


DESIGN CRITERIA
CONCRETE COMP. STRENGTH
B. PLATE YIELD STRESS
COLUMN AXIAL LOAD
COLUMN
WEB DEPTH
WEB THICKNESS
FLANGE WIDTH
FLANGE THICKNESS
R. PLATE THICKNESS
NO. OF RIB PLATE
B. PLATE WIDTH
LENGTH
AREA
PEDESTAL AREA
BEARING
ALLOW. BEARING STRESS
ACTUAL BEARING STRESS
SAFETY FACTOR
BENDING
CRITICAL
BENDING
LENGTHS
(max. of m, n, n')
REQUIRED THICK. OF PLATE

ADOPT

09/06/2016

BP1
fc'
Fy
P

20.70 mpa
248.22 mpa
6.85 kn

d 863.60 mm
tw
17.48 mm
bf 863.60 mm
tf
17.48 mm
tr
20.00 mm
nr
20
B 300.00 mm
N 150.00 mm
A1 45,000 mm2
A2 175,000 mm2
Fp
fp
F.S.

14.29 mpa
0.15 mpa
93.80 OK !

m -335.21 mm
n -195.44 mm
n'
2.51 mm
l
2.51 mm
tp
0.12 mm

2 x 300 x 150 mm BASE PLATE

Page 1

ANCHOR BOLT
DESIGN CRITERIA
BOLT TYPE (A325/A490)
CONNECTION TYPE (FS, FO, FL/B)
FS - friction, standard size
F0 - friction, oversized
FL - friction, long slotted
B - bearing type
TENSILE FORCE
SHEAR FORCE
BOLT
### COMBINED SHEAR & TENSION
ALLOWABLE SHEAR STRESS
ALLOWABLE TENSILE STRESS
AREA OF 1- BOLT
TOTAL BOLT AREA
ACTUAL SHEAR STRESS
SAFETY FACTOR
ACTUAL TENSILE STRESS
SAFETY FACTOR
PULL-OUT
ALLOWABLE BOND STRESS
EMBEDDED LENGTH

#DIV/0!

A325
FS

T
V

1.00 kn
0.00 kn
16 mm

Fv 120.00 mpa
Ft 300.00 mpa
Ab 197.93 mm2
A 1979.30 mm2
fv
0.00 mpa
SF #DIV/0!
ft
0.51 mpa
SF 593.79

U
L

0.83 mpa
634.09 mm

10 - 16 x 635mm A. BOLT

MEGATECH DESIGNERS CONSULTANTS INT'L Confidential

09/06/2016

AB1
REMARK
(Thread
excluded
from shear
plane)

#DIV/0!
OK !

635

10 - 16 x 635mm A. BOLT

Page 2

SUPPORT REACTION
JOINT 1
X
DL
0.00
LL
0.00
WL
0.00
SL
-1.21
LOAD COMBINATION
DL+LL
0.00
0.75(DL+LL+WL)
0.00
0.75(DL+WL)
0.00
0.75(DL+LL+SL)
-0.91
0.75(DL+SL)
-0.91
MAX. COMP.
MAX. TENSION
SHEAR
0.91

JOINT 2
Y
X
32.16 DL
0.00
26.44 LL
0.00
0.00 WL
0.00
216.12 SL
39.53
LOAD COMBINATION
58.60 DL+LL
0.00
43.95 0.75(DL+LL+WL)
0.00
24.12 0.75(DL+WL)
0.00
206.04 0.75(DL+LL+SL)
29.65
186.21 0.75(DL+SL)
29.65
206.04 MAX. COMP.
0.00 MAX. TENSION
SHEAR
29.65

Y
32.16
26.44
0.00
-216.12
58.60
43.95
24.12
-118.14
-137.97
58.60
-137.97

Sheet3

PROJECT: STEEL BUILDING DESIGN CASE STUDY


SUBJECT: Tension member design. Bolted connection.
SHEET 101 of 131
Connection for a 38.3 foot long tension member that has to resist 78 kips of already factored load.
No slip is permitted, so this connection is slip critical.
t = resistance factor relating to tensile strength
Ag = gross cross-sectional area
Ae = U*An
U = reduction coefficient
Fy = specified (ASTM) minimum yield stress
Fu = specified (ASTM) minimum tensile strength
d = diameter of the bolt
An = net area
Rn = strength
Rstr = slip critical strength
Lc = distance from edge of hole to edge of connected part
t = thickness of connected part
Ab = nominal bolt area
Pu = factored load to be resisted
Fv = ultimate shearing strength
= mean slip coefficient (coefficient of static friction)
Tb = minimum fastener tension
Agv = gross area acted upon by shear
Agt = gross area acted upon by tension
Anv = net area acted upon by shear
Ant = net area acted upon by tension

Because the bolt size and layout will affect the net area of the tension member, we will begin with
the selection of the bolts. Use A325 bolts and A572 Grade 36 steel for both the tension member and
the gusset plate (standard holes).

t=

TRY :
3/8
Ab =
0.60
Shear strength:
Rn= Fv Ab

3/4

(in) bolts
(in2)

Pu =
=
Fv =
=
Fy =
Fu =
L=

in

Tb =
Ns =

39
2

(kips) from table J3.1 LRFD

(assuming that the threads are in the shear plane)


Rn=
21.65 Kips/bolt

Page 4

76
0.75
48
0.33
36
58.0
38.3

Sheet3

Rstr = (1.13 Tb b Ns)

Shear strength controls

Rstr =

29.09

Kips/bolt

Rn =

21.65

Kips/bolt
Red font indicates user input

PROJECT: STEEL BUILDING DESIGN CASE STUDY


SUBJECT: Bolted connection

Number of bolts required =


Try =
4
bolts
Minimum spacing :

bolts

the distance between centers of standard, oversized, or slotted holes, shall


not be less than 3d (from AISC J3.3).
s =3 d=
2.63
in
say, s =
3
in

Minimum edge distance :


Le =

Ag req.
U=
0.85
Ae req.
An req.

3.51

SHEET 102 of 131

(from AISC table J3.4)


1.5
in

2.345679 in2
(from commentary to the AISC specification)
1.7471264 in2
2.0554429 in2

minimum radius of gyration:


r min =
1.532 in
TRY

2L5x3x1/2LLBB
bolts placed in the long leg at the usual gage distance (check LRFD page 10-10)
usual gage =
3
in
Ag =
7.51
in2
>
2.35
in2
OK!
r=
1.58
in
>
1.53
in
OK!
t=
0.5
in
An =
7.01
in2
>
2.0554429 in2
OK!
x = 0.736 in
U = 0.9182222
<
0.9
use U =
0.9
Ae = 6.309 in2
>
1.7471264 in2
OK!
Check Bearing strength:
for bearing strength computation use a hole diameter of h =
Rn = (1.2 Lc t Fu)
if Lc < 2 d
Rn = (2.4 d t Fu)
if Lc > 2 d

Page 5

15/16

in

Sheet3

For the hole nearest the edge of the member :


Lc =
1.03
in
Rn =
2d=
1.75
in
For the other holes:
Lc =
2.06
in
Rn =
2d=
1.75
in
Total bearing strength of the connection :
Rn =

163.94 kips >

76 kips

26.92

kips/bolt

45.68

kips/bolt

OK!

Red font indicates user input

PROJECT: STEEL BUILDING DESIGN CASE STUDY


SUBJECT: Bolted connection

SHEET 103 of 131

Check Block shear:


Shear areas:
Agv =
5.25
Anv =
3.50

in2
in2

Tension areas:
Agt =
0.50
Ant =
0.25

in2
in2

Shear rupture design strength Vn:


(.6*Fu)*Anv =

LRFD J4-1
91.35 kips

Tension rupture design strength Tn:


Fu*Ant =

LRFD J4-2
10.875 kips

The larger fracture term controls:

LRFD J4-1 controls

Block shear strength:


Rn =
Rn =

104.85
102.225

kips <
kips >

102.225
Pu/2 =

38

kips

OK!

Le =
Le =

1.5

in

s=

Page 6

in.

1.5

in

Sheet3

g=

in

Use a
Use

2L5x3x1/2LLBB
4
7/8

with the long leg connected.


in. A325 bolts.

Red font indicates user input

Page 7

Sheet3

EET 101 of 131

(kips)
(ksi)
(ksi)
(ksi)
(ft)

table J3.1 LRFD

Page 8

Sheet3

ET 102 of 131

otted holes, shall

0-10)

Page 9

Sheet3

ET 103 of 131

Page 10

Sheet3

Page 11

Sheet16

Page 12

Sheet16

RENZXYMON

Page 13

Sheet16

RENZXYMON

Page 14

You might also like