owner specifies
only on shell plates inch
must be within spacing requirements as per Fig. 9-1
maximum size 48 vertical x 72 horizontal and minimum
dimension 4
e. areas on which lap patch is to be put shall be UT checked
f. lap on lap is not permitted
11.
All shell plate defects like the cracks, gauges, tears, widely
scattered .pits and corroded areas shall be evaluated case by case
as per chapter 4 of API 653.
12.
13.
14.
If impact test was not done on original tank material, the hot taps
shall be limited to NPS 4 (max).
15.