You are on page 1of 606

30-00-00

OPERATIONAL TEST OF
STANDBY DE-ICING SYSTEM
AND ASSOCIATED ALERTS

OPT 10000-001
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 210
435
445
: 214BZ
435AL 445AL

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

GSE

: 01 ACCESS PLATFORM
01 COMPRESSOR

_________
MAN-HOURS

PUBLICATION
___________
JIC
JIC

: OPENING AND CLOSING OF


HINGED ENGINE COWLS
: DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY

AH

54-00-00-OAC-10000
24-46-00-EAD-10000

30-00-00
OPT 10000-001
2-400 PAGE
1
DEC 01/14

30-00-00

OPERATIONAL TEST OF
STANDBY DE-ICING SYSTEM
AND ASSOCIATED ALERTS

001

OPT 10000-001
2

DEC14

___________
PREPARATION
1. INSTALL PLATFORM SO AS TO HAVE ACCESS TO
FOLLOWING EQUIPMENTS :
- ON ENGINE L AND R
. VALVE SHUT OFF REGULATOR 13DM (14DM).
2. OPEN ENGINE PANELS 435AL (445AL).
3. ON ELECTRIC RACK 90VU, OPEN ACCESS PANEL
214BZ TO GAIN ACCESS TO STANDBY DE-ICING
CONTROL UNIT 109DM.

002

___________________________________
OPENING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000

003

ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


___________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

004

____________________________________________
OPERATIONNAL
TEST OF STANDBY DE ICING SYSTEM
REF.
REF.
REF.
REF.

FIG.
FIG.
FIG.
FIG.

301100-OPT-00110
301100-OPT-00100
300000-OPT-00100
301100-OPT-00170

ON PANEL 702VU, PLACE WEIGHT ON WHEELS


SWITCH ON FLT POSITION.
1. TO PERFORM TEST, CONNECT GROUND AIR PRESSURIZATION UNIT 4 BARS (58 PSI) (60 L/SEC)
TO LEFT REGULATOR VALVE TEST PLUG.
NOTE : THIS TEST CAN ALSO BE PERFORMED ENGINES RUNNING.
AFTER AN ENGINE CHANGE, PERFORM TEST
*** CONTINUED ***
AH

30-00-00
OPT 10000-001
2-400 PAGE
2
DEC 01/14

30-00-00

OPERATIONAL TEST OF
STANDBY DE-ICING SYSTEM
AND ASSOCIATED ALERTS

OPT 10000-001
3

DEC14

DURING ENGINE RUN-UP.


2. ON PANEL 24VU,
A. CHECK THAT (20DM) AFR AIR BLEED
PUSHBUTTON SWITCH (2) IS PRESSED :
- FAULT LEGEND OFF,
- OFF LEGEND OFF.
B. PRESS (150DH) MODE SEL/AUTO PUSHBUTTON
SWITCH (5) :
- FAULT LEGEND OFF,
- MAN LEGEND ON.
C. CHECK THAT (6DM)MOD SEL PUSHBUTTON
SWITCH(1) IS RELEASED :
- SLOW LEGEND OFF.
D. PRESS (1DN) ENG1 (6), (2DN) ENG2 (7)
AND (7DM) AIR FRAME (3) :
- FAULT LEGENDS OFF,
- ON LEGENDS ON.
E. ON PANEL 402VU, CHECK THAT (12DM)
DE ICING ANNUNCIATOR (4) IS ON.
3. WAIT COMPLETE CYCLE I.E. 60 SECONDS :
- NO WARNING MUST BE ACTIVATED.
4. ON PANEL 24VU,
A. PRESS (107DM) MODE SEL/NORM PUSHBUTTON
SWITCH (12) :
- FAULT LEGEND OFF,
- OVRD LEGEND ON.
B. ALL LEGENDS OF PUSHBUTTON SWITCHES
AFR AIR BLEED (2), ENG1 (6), ENG2
AND AIR FRAME (3) DISAPPEARED.
C. FOLLOWING WARNINGS APPEARS :
*** CONTINUED ***
AH

30-00-00
OPT 10000-001
2-400 PAGE
3
DEC 01/14

30-00-00

OPERATIONAL TEST OF
STANDBY DE-ICING SYSTEM
AND ASSOCIATED ALERTS

OPT 10000-001
4

DEC14

CAUTION LEGEND COMES ON,


SINGLE CHIME SOUNDS.
ON CAP, ANTI ICING CAUTION LIGHT COMES ON
5. DURING INFLATING CYCLE, CHECK THAT A AND B
BOOTS OF AIRFRAME AND ENGINE DE-ICERINFLATE
ACCORDING TO DEFINED CYCLE(REF. FIG 300000OPT-00100).
6. ON PANEL 24VU,
A. RELEASE (107DM) MODE SEL/NORM PUSHBUTTON SWITCH (12) :
- FAULT LEGEND OFF,
- OVRD LEGEND OFF.
B. ALL LEGENDS OF PUSHBUTTON SWITCHES
REAPPEARED :
- (1DN) ENG1 (6), (2DN) ENG (7) AND
(7DM) AFR FRAME (3)
. FAULT LEGENDS ON,
. ON LEGENDS ON.
C. RESET PUSHBUTTON SWITCHES (1DN) ENG1
(6), (2DN) ENG (7) AND (7DM) AFR FRAME
(3)
- FAULT LEGENDS OFF,
- ON LEGENDS ON.
D. THE CYCLE START, WAIT COMPLETE CYCLE.
DURING INFLATING CYCLE CHECK THAT BOOTS
A AND B OF AIRFRAME AND ENGINE DE-ICER
INFLATE.
- NO WARNING MUST BE ACTIVATED.
7. TEST OF STANDBY DE ICING CONTROL UNIT.
A. ON PANEL 24VU, RELEASE PUSHBUTTON
SWITCH :
- (7DM) AIR FRAME (3)
. FAULT LEGEND OFF,
*** CONTINUED ***
AH

30-00-00
OPT 10000-001
2-400 PAGE
4
DEC 01/14

OPERATIONAL TEST OF
STANDBY DE-ICING SYSTEM
AND ASSOCIATED ALERTS

30-00-00

OPT 10000-001
5

DEC14

. ON LEGEND OFF.


B. ON RACK 93VU, HOLD TEST PUSHBUTTON SWITCH
T1 PRESSED OF STANDBY DE-ICING CONTROL
UNIT (109DM).
- ON PANEL 24VU,
. FAULT LEGEND OF (107DM) MODE SEL/
NORM PUSHBUTTON SWITCH (12) IS ON
50 SECONDS PER MINUTE (UNLIGHTED
DURING INFLATING CYCLE OF ENGINE
DE-ICER).
- THE FOLLOWING WARNINGS LIGHT IN
SAME TIME OF FAULT LEGEND OF
PUSHBUTTON SWITCH (107DM).
. ANNUNCIATOR CAUTION (ANNUNCIATOR DO
NOT FLASH).
. ON CAP, ANTI-ICING LEGEND.
RELEASE TEST PUSHBUTTON SWITCH T1.
C. HOLD TEST PUSHBUTTON SWITCH T2
PRESSED :
- ON PANEL 24VU,
. FAULT LEGEND OF (107DM) MODE
SEL/NORM PUSHBUTTON SWITCH (12) IS
ON 10 SECONDS PER MINUTE (LIGHTED
DURING INFLATING CYCLE OF ENGINE
DE-ICER).
- THE FOLLOWING WARNINGS LIGHT IN SAME
TIME OF FAULT LEGEND OF PUSHBUTTON
SWITCH (107DM).
. ANNUNCIATOR CAUTION,
. ON CAP, ANTI ICING LEGEND.
RELEASE TEST PUSHBUTTON SWITCH T2.
D. ON PANEL 24VU,
- RELEASE (1DN) ENG1 AND (2DN) ENG2
*** CONTINUED ***
AH

30-00-00
OPT 10000-001
2-400 PAGE
5
DEC 01/14

30-00-00

OPERATIONAL TEST OF
STANDBY DE-ICING SYSTEM
AND ASSOCIATED ALERTS

OPT 10000-001
6

DEC14

PUSHBUTTON SWITCHES (6) AND (7).


- RELEASE(150DH) MODE SEL/AUTO
PUSHBUTTON SWITCH (5) :
. FAULT LEGEND OFF,
. MAN LEGEND OFF.
8. DISCONNECT COMPRESSOR.
NOTE: REPEAT TEST CONNECTING COMPRESSOR TO
REGULATOR VALVE (14DM) ON RIGHT ENGINE
9. ON PANEL 702VU, PLACE WEIGHT ON WHEELS
SWITCH ON NORM POSITION.
005

DE-ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


______________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

006

________
CLOSE-UP
1. MAKE CERTAIN THAT WORKING AREA IS CLEAN AND
CLEAR OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
2. REMOVE ACCESS PLATFORMS AFTER HAVING CLOSED
ENGINE COWLS 435AL AND 445AL AS FOLLOWS:

007

___________________________________
CLOSING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000
*****

AH

E N D

O F

T E X T

*****

30-00-00
OPT 10000-001
2-400 PAGE
6
DEC 01/14

30-00-00
7

AH

TEST COUPLING - PRESSURE


REGULATOR AND SHUT-OFF
VALVE

OPT 10000-001
DEC14

30-00-00
OPT 10000-001

2-400

PAGE
7
DEC 01/14

30-00-00
8

AH

CONTROLS AND INDICATING


WING/ENGINE DE ICING

OPT 10000-001
DEC14

30-00-00
OPT 10000-001

2-400

PAGE
8
DEC 01/14

30-00-00
9

AH

PNEUMATIC STANDBY
DE-ICING CYCLE

OPT 10000-001
DEC14

30-00-00
OPT 10000-001

2-400

PAGE
9
DEC 01/14

30-00-00
10

AH

OPERATIONAL TEST OF
STANDBY DE ICING

OPT 10000-001
DEC14

30-00-00
OPT 10000-001

2-400

PAGE
10
DEC 01/14

30-00-00

OPERATIONAL TEST OF
STANDBY DE-ICING SYSTEM
AND ASSOCIATED ALERTS

OPT 10000-002
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 210
435
445
: 214BZ
435AL 445AL

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

GSE

: 01 ACCESS PLATFORM
01 COMPRESSOR

_________
MAN-HOURS

PUBLICATION
___________
JIC
JIC

: OPENING AND CLOSING OF


HINGED ENGINE COWLS
: DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY

AH

54-00-00-OAC-10000
24-46-00-EAD-10000

30-00-00
OPT 10000-002
2-400 PAGE
1
DEC 01/14

30-00-00

OPERATIONAL TEST OF
STANDBY DE-ICING SYSTEM
AND ASSOCIATED ALERTS

001

OPT 10000-002
2

DEC14

___________
PREPARATION
1. INSTALL PLATFORM SO AS TO HAVE ACCESS TO
FOLLOWING EQUIPMENTS :
- ON ENGINE L AND R
. VALVE SHUT OFF REGULATOR 13DM (14DM).
2. OPEN ENGINE PANELS 435AL (445AL).
3. ON ELECTRIC RACK 90VU, OPEN ACCESS PANEL
214BZ TO GAIN ACCESS TO STANDBY DE-ICING
CONTROL UNIT 109DM.

002

___________________________________
OPENING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000

003

ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


___________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

004

____________________________________________
OPERATIONNAL
TEST OF STANDBY DE ICING SYSTEM
REF.
REF.
REF.
REF.

FIG.
FIG.
FIG.
FIG.

301100-OPT-00110
301100-OPT-00100
300000-OPT-00100
301100-OPT-00170

ON PANEL 702VU, PLACE WEIGHT ON WHEELS


SWITCH ON FLT POSITION.
1. TO PERFORM TEST, CONNECT GROUND AIR PRESSURIZATION UNIT 4 BARS (58 PSI) (60 L/SEC)
TO LEFT REGULATOR VALVE TEST PORT 1.
NOTE : THIS TEST CAN ALSO BE PERFORMED ENGINES RUNNING.
AFTER AN ENGINE CHANGE, PERFORM TEST
*** CONTINUED ***
AH

30-00-00
OPT 10000-002
2-400 PAGE
2
DEC 01/14

30-00-00

OPERATIONAL TEST OF
STANDBY DE-ICING SYSTEM
AND ASSOCIATED ALERTS

OPT 10000-002
3

DEC14

DURING ENGINE RUN-UP.


2. ON PANEL 24VU,
A. CHECK THAT (20DM) AFR AIR BLEED
PUSHBUTTON SWITCH (2) IS PRESSED :
- FAULT LEGEND OFF,
- OFF LEGEND OFF.
B. PRESS (150DH) MODE SEL/AUTO PUSHBUTTON
SWITCH (5) :
- FAULT LEGEND OFF,
- MAN LEGEND ON.
C. CHECK THAT (6DM)MOD SEL PUSHBUTTON
SWITCH(1) IS RELEASED :
- SLOW LEGEND OFF.
D. PRESS (1DN) ENG1 (6), (2DN) ENG2 (7)
AND (7DM) AIR FRAME (3) :
- FAULT LEGENDS OFF,
- ON LEGENDS ON.
E. ON PANEL 402VU, CHECK THAT (12DM)
DE ICING ANNUNCIATOR (4) IS ON.
3. WAIT COMPLETE CYCLE I.E. 60 SECONDS :
- NO WARNING MUST BE ACTIVATED.
4. ON PANEL 24VU,
A. PRESS (107DM) MODE SEL/NORM PUSHBUTTON
SWITCH (12) :
- FAULT LEGEND OFF,
- OVRD LEGEND ON.
B. ALL LEGENDS OF PUSHBUTTON SWITCHES
AFR AIR BLEED (2), ENG1 (6), ENG2
AND AIR FRAME (3) DISAPPEARED.
C. FOLLOWING WARNINGS APPEARS :
*** CONTINUED ***
AH

30-00-00
OPT 10000-002
2-400 PAGE
3
DEC 01/14

30-00-00

OPERATIONAL TEST OF
STANDBY DE-ICING SYSTEM
AND ASSOCIATED ALERTS

OPT 10000-002
4

DEC14

CAUTION LEGEND COMES ON,


SINGLE CHIME SOUNDS.
ON CAP, ANTI ICING CAUTION LIGHT COMES ON
5. DURING INFLATING CYCLE, CHECK THAT A AND B
BOOTS OF AIRFRAME AND ENGINE DE-ICERINFLATE
ACCORDING TO DEFINED CYCLE(REF. FIG 300000OPT-00100).
6. ON PANEL 24VU,
A. RELEASE (107DM) MODE SEL/NORM PUSHBUTTON SWITCH (12) :
- FAULT LEGEND OFF,
- OVRD LEGEND OFF.
B. ALL LEGENDS OF PUSHBUTTON SWITCHES
REAPPEARED :
- (1DN) ENG1 (6), (2DN) ENG (7) AND
(7DM) AFR FRAME (3)
. FAULT LEGENDS ON,
. ON LEGENDS ON.
C. RESET PUSHBUTTON SWITCHES (1DN) ENG1
(6), (2DN) ENG (7) AND (7DM) AFR FRAME
(3)
- FAULT LEGENDS OFF,
- ON LEGENDS ON.
D. THE CYCLE START, WAIT COMPLETE CYCLE.
DURING INFLATING CYCLE CHECK THAT BOOTS
A AND B OF AIRFRAME AND ENGINE DE-ICER
INFLATE.
- NO WARNING MUST BE ACTIVATED.
7. TEST OF STANDBY DE ICING CONTROL UNIT.
A. ON PANEL 24VU, RELEASE PUSHBUTTON
SWITCH :
- (7DM) AIR FRAME (3)
. FAULT LEGEND OFF,
*** CONTINUED ***
AH

30-00-00
OPT 10000-002
2-400 PAGE
4
DEC 01/14

OPERATIONAL TEST OF
STANDBY DE-ICING SYSTEM
AND ASSOCIATED ALERTS

30-00-00

OPT 10000-002
5

DEC14

. ON LEGEND OFF.


B. ON RACK 93VU, HOLD TEST PUSHBUTTON SWITCH
T1 PRESSED OF STANDBY DE-ICING CONTROL
UNIT (109DM).
- ON PANEL 24VU,
. FAULT LEGEND OF (107DM) MODE SEL/
NORM PUSHBUTTON SWITCH (12) IS ON
50 SECONDS PER MINUTE (UNLIGHTED
DURING INFLATING CYCLE OF ENGINE
DE-ICER).
- THE FOLLOWING WARNINGS LIGHT IN
SAME TIME OF FAULT LEGEND OF
PUSHBUTTON SWITCH (107DM).
. ANNUNCIATOR CAUTION (ANNUNCIATOR DO
NOT FLASH).
. ON CAP, ANTI-ICING LEGEND.
RELEASE TEST PUSHBUTTON SWITCH T1.
C. HOLD TEST PUSHBUTTON SWITCH T2
PRESSED :
- ON PANEL 24VU,
. FAULT LEGEND OF (107DM) MODE
SEL/NORM PUSHBUTTON SWITCH (12) IS
ON 10 SECONDS PER MINUTE (LIGHTED
DURING INFLATING CYCLE OF ENGINE
DE-ICER).
- THE FOLLOWING WARNINGS LIGHT IN SAME
TIME OF FAULT LEGEND OF PUSHBUTTON
SWITCH (107DM).
. ANNUNCIATOR CAUTION,
. ON CAP, ANTI ICING LEGEND.
RELEASE TEST PUSHBUTTON SWITCH T2.
D. ON PANEL 24VU,
- RELEASE (1DN) ENG1 AND (2DN) ENG2
*** CONTINUED ***
AH

30-00-00
OPT 10000-002
2-400 PAGE
5
DEC 01/14

30-00-00

OPERATIONAL TEST OF
STANDBY DE-ICING SYSTEM
AND ASSOCIATED ALERTS

OPT 10000-002
6

DEC14

PUSHBUTTON SWITCHES (6) AND (7).


- RELEASE(150DH) MODE SEL/AUTO
PUSHBUTTON SWITCH (5) :
. FAULT LEGEND OFF,
. MAN LEGEND OFF.
8. DISCONNECT COMPRESSOR.
NOTE: REPEAT TEST CONNECTING COMPRESSOR TO
REGULATOR VALVE (14DM) ON RIGHT ENGINE
9. ON PANEL 702VU, PLACE WEIGHT ON WHEELS
SWITCH ON NORM POSITION.
005

DE-ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


______________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

006

________
CLOSE-UP
1. MAKE CERTAIN THAT WORKING AREA IS CLEAN AND
CLEAR OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
2. REMOVE ACCESS PLATFORMS AFTER HAVING CLOSED
ENGINE COWLS 435AL AND 445AL AS FOLLOWS:

007

___________________________________
CLOSING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000
*****

AH

E N D

O F

T E X T

*****

30-00-00
OPT 10000-002
2-400 PAGE
6
DEC 01/14

30-00-00
7

AH

TEST COUPLING - PRESSURE


REGULATOR AND SHUT-OFF
VALVE

OPT 10000-002
DEC14

30-00-00
OPT 10000-002

2-400

PAGE
7
DEC 01/14

30-00-00
8

AH

CONTROLS AND INDICATING


WING/ENGINE DE ICING

OPT 10000-002
DEC14

30-00-00
OPT 10000-002

2-400

PAGE
8
DEC 01/14

30-00-00
9

AH

PNEUMATIC STANDBY
DE-ICING CYCLE

OPT 10000-002
DEC14

30-00-00
OPT 10000-002

2-400

PAGE
9
DEC 01/14

30-00-00
10

AH

OPERATIONAL TEST OF
STANDBY DE ICING

OPT 10000-002
DEC14

30-00-00
OPT 10000-002

2-400

PAGE
10
DEC 01/14

30-00-00

OPERATIONAL TEST OF
STANDBY DE-ICING SYSTEM
AND ASSOCIATED ALERTS

OPT 10000-003
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 210
435
445
: 214BZ
435AL 445AL

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

GSE

: 01 ACCESS PLATFORM
01 COMPRESSOR

_________
MAN-HOURS

PUBLICATION
___________
JIC
JIC
JIC

: PRINCIPLE OF CDS USE


(DISPLAY UNITS
EXPLORATION)
: OPENING AND CLOSING OF
HINGED ENGINE COWLS
: DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY

AH

31-63-00-PRO-10000
54-00-00-OAC-10000
24-46-00-EAD-10000

30-00-00
OPT 10000-003
2-400 PAGE
1
DEC 01/14

30-00-00

OPERATIONAL TEST OF
STANDBY DE-ICING SYSTEM
AND ASSOCIATED ALERTS

001

OPT 10000-003
2

DEC14

PRINCIPLE OF CDS USE (DISPLAY UNITS


___________________________________
EXPLORATION)
____________
(TO USE ONLY IF NEEDED)
_______________________
SEE JOB INSTRUCTION CARD
316300-PRO-10000
NOTE: PROCEDURE TO USE ONLY IF NEEDED.
THIS PROCEDURE DESCRIBES LOCATION AND
MANAGEMENT OF THE DIFFERENT DISPLAY
WINDOWS PROVIDED BY THE THREE FORMATS
(PFD, EWD, MFD) PROPOSED ON THE FIVE
DISPLAY UNITS (DU).

002

___________
PREPARATION
1. INSTALL PLATFORM SO AS TO HAVE ACCESS TO
FOLLOWING EQUIPMENTS :
- ON ENGINE L AND R
. VALVE SHUT OFF REGULATOR 13DM (14DM).
2. OPEN ENGINE PANELS 435AL (445AL).
3. ON ELECTRIC RACK 90VU, OPEN ACCESS PANEL
214BZ TO GAIN ACCESS TO STANDBY DE-ICING
CONTROL UNIT 109DM.

003

___________________________________
OPENING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000

004

ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


___________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

*** CONTINUED ***


AH

30-00-00
OPT 10000-003
2-400 PAGE
2
DEC 01/14

30-00-00

OPERATIONAL TEST OF
STANDBY DE-ICING SYSTEM
AND ASSOCIATED ALERTS

005

OPT 10000-003
3

DEC14

____________________________________________
OPERATIONNAL
TEST OF STANDBY DE ICING SYSTEM
REF.
REF.
REF.
REF.

FIG.
FIG.
FIG.
FIG.

301100-OPT-00110
301100-OPT-00100
300000-OPT-00100
301100-OPT-00170

ON PANEL 702VU, PLACE WEIGHT ON WHEELS


SWITCH ON FLT POSITION.
1. TO PERFORM TEST, CONNECT GROUND AIR PRESSURIZATION UNIT 4 BARS (58 PSI) (60 L/SEC)
TO LEFT REGULATOR VALVE TEST PORT 1.
NOTE : THIS TEST CAN ALSO BE PERFORMED
ENGINES RUNNING.
AFTER AN ENGINE CHANGE, PERFORM TEST
DURING ENGINE RUN-UP.
2. ON PANEL 24VU,
A. CHECK THAT AFR AIR BLEED
PUSHBUTTON SWITCH (2) IS PRESSED :
- FAULT LEGEND OFF,
- OFF LEGEND OFF.
B. PRESS MODE SEL/AUTO PUSHBUTTON
SWITCH (5) :
- FAULT LEGEND OFF,
- MAN LEGEND ON.
- ON EWD, IN ALERT WINDOW, A-ICING AUTO
MESSAGE APPEARS.
C. CHECK THAT MOD SEL PUSHBUTTON
SWITCH(1) IS RELEASED :
- SLOW LEGEND OFF.
D. PRESS ENG1 (6), ENG2 (7)
AND AIR FRAME (3) :
- FAULT LEGENDS OFF,
- ON LEGENDS ON.
*** CONTINUED ***
AH

30-00-00
OPT 10000-003
2-400 PAGE
3
DEC 01/14

30-00-00

OPERATIONAL TEST OF
STANDBY DE-ICING SYSTEM
AND ASSOCIATED ALERTS

OPT 10000-003
4

DEC14

- ON MFD, IN TEMPORARY SELECTION WINDOW,


CYAN 1 ENG 2  AND AIRFRAME MESSAGES
APPEAR.
3. WAIT COMPLETE CYCLE I.E. 60 SECONDS :
- ON EWD, IN ALERT WINDOW, NO ALERT MUST BE
ACTIVATED.
4. ON PANEL 24VU,
A. PRESS MODE SEL/NORM PUSHBUTTON
SWITCH (12) :
- FAULT LEGEND OFF,
- OVRD LEGEND ON.
B.- ALL LEGENDS OF PUSHBUTTON SWITCHES
AFR AIR BLEED (2), ENG1 (6), ENG2
(7) AND AIR FRAME (3) DISAPPEARED.
- ON MFD, IN TEMPORARY SELECTION WINDOW,
1 ENG 2 AND AIRFRAME MESSAGES
DISAPPEAR.
- MASTER CAUTION LIGHTS COME ON
- SINGLE CHIME SOUNDS.
C. FOLLOWING WARNINGS APPEARS:
- CAUTION LEGEND COMES ON,
- SINGLE CHIME SOUNDS.
5. DURING INFLATING CYCLE, CHECK THAT A AND B
BOOTS OF AIRFRAME AND ENGINE DE-ICERINFLATE
ACCORDING TO DEFINED CYCLE(REF. FIG 300000OPT-00100).
6. ON PANEL 24VU,
A. RELEASE MODE SEL/NORM PUSHBUTTON
SWITCH (12) :
- FAULT LEGEND OFF,
- OVRD LEGEND OFF.
B. ALL LEGENDS OF PUSHBUTTON SWITCHES
REAPPEARED :
- ENG1 (6), ENG (7) AND
*** CONTINUED ***
AH

30-00-00
OPT 10000-003
2-400 PAGE
4
DEC 01/14

OPERATIONAL TEST OF
STANDBY DE-ICING SYSTEM
AND ASSOCIATED ALERTS

30-00-00

OPT 10000-003
5

DEC14

AIR FRAME (3)


. FAULT LEGENDS ON,
. ON LEGENDS ON.
- ON MFD, IN TEMPORARY SELECTION WINDOW,
AMBER 1 ENG 2 AND AIRFRAME MESSAGES
APPEAR.
- ON EWD, IN ALERT WINDOW, A-ICING ENG1
A-ICING ENG2 AND A-ICING FRAME
MESSAGES APPEAR.
- A-ICING SEL MESSAGE DISAPPEARS.
- MASTER CAUTION LIGHTS GO ON.
- ACTIVATION OF THE SINGLE CHIME.
C.- RESET PUSHBUTTON SWITCHES ENG1
(6), ENG 2 (7) AND AIR FRAME (3)
. FAULT LEGENDS OFF,
. ON LEGENDS ON.
- ON MFD, IN TEMPORARY SELECTION WINDOW,
CYAN 1 ENG 2 AND AIRFRAME MESSAGE
APPEAR.
- MASTER CAUTION LIGHTS GO OFF.
D. THE CYCLE START, WAIT COMPLETE CYCLE.
DURING INFLATING CYCLE CHECK THAT BOOTS
A AND B OF AIRFRAME AND ENGINE DE-ICER
INFLATE.
- ON EWD, IN ALERT WINDOW, NO MESSAGE
MUST BE DISPLAYED.
7. TEST OF STANDBY DE ICING CONTROL UNIT.
A.- ON PANEL 24VU, RELEASE PUSHBUTTON
SWITCH AIR FRAME (3)
. FAULT LEGEND OFF,
. ON LEGEND OFF.
- ON MFD, IN TEMPORARY SELECTION WINDOW,
CYAN AIRFRAME MESSAGE DISAPPEARS.
B. ON RACK 93VU, HOLD TEST PUSHBUTTON SWITCH
T1 PRESSED OF STANDBY DE-ICING CONTROL
UNIT.
- ON PANEL 24VU,
*** CONTINUED ***
AH

30-00-00
OPT 10000-003
2-400 PAGE
5
DEC 01/14

OPERATIONAL TEST OF
STANDBY DE-ICING SYSTEM
AND ASSOCIATED ALERTS

30-00-00

OPT 10000-003
6

DEC14

. FAULT LEGEND OF MODE SEL/NORM


PUSHBUTTON SWITCH (12) IS ON 50
SECONDS PER MINUTE (UNLIGHTED DURING
INFLATING CYCLE OF ENGINE DE-ICER).
- ON EWD, IN ALERT WINDOW, A-ICING SEL
MESSAGE APPEARS.
- ACTIVATION OF THE SINGLE CHIME.
- MASTER CAUTION LIGHTS ARE LIGHTED (DO
NOT FLASH)
RELEASE TEST PUSHBUTTON SWITCH T1.
- ON EWD, IN ALERT WINDOW, A-ICING SEL
MESSAGE DISAPPEARS.
- MASTER CAUTION LIGHTS GO OFF.
C. HOLD TEST PUSHBUTTON SWITCH T2
PRESSED :
- ON PANEL 24VU,
. FAULT LEGEND OF MODE SEL/NORM
PUSHBUTTON SWITCH (12) IS ON 10
SECONDS PER MINUTE (LIGHTED DURING
INFLATING CYCLE OF ENGINE DE-ICER).
- ON EWD, IN ALERT WINDOW, A-ICING SEL
MESSAGE APPEARS.
- ACTIVATION OF THE SINGLE CHIME
- MASTER CAUTION LIGHTS FLASH.
D. ON PANEL 24VU,
- RELEASE ENG1 AND ENG2 PUSBUTTON
SWITCHES (6) AND (7).
. FAULT LEGEND OFF,
SWITCH ON NORM POSITION.

*** CONTINUED ***


AH

30-00-00
OPT 10000-003
2-400 PAGE
6
DEC 01/14

30-00-00

OPERATIONAL TEST OF
STANDBY DE-ICING SYSTEM
AND ASSOCIATED ALERTS

OPT 10000-003
7

DEC14

SWITCH ON NORM POSITION.


006

DE-ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


______________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

007

________
CLOSE-UP
1. MAKE CERTAIN THAT WORKING AREA IS CLEAN AND
CLEAR OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
2. REMOVE ACCESS PLATFORMS AFTER HAVING CLOSED
ENGINE COWLS 435AL AND 445AL AS FOLLOWS:

008

___________________________________
CLOSING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000
*****

AH

E N D

O F

T E X T

*****

30-00-00
OPT 10000-003
2-400 PAGE
7
DEC 01/14

30-00-00
8

AH

TEST COUPLING - PRESSURE


REGULATOR AND SHUT-OFF
VALVE

OPT 10000-003
DEC14

30-00-00
OPT 10000-003

2-400

PAGE
8
DEC 01/14

30-00-00
9

AH

CONTROLS AND INDICATING


WING/ENGINE DE ICING

OPT 10000-003
DEC14

30-00-00
OPT 10000-003

2-400

PAGE
9
DEC 01/14

30-00-00
10

AH

PNEUMATIC STANDBY
DE-ICING CYCLE

OPT 10000-003
DEC14

30-00-00
OPT 10000-003

2-400

PAGE
10
DEC 01/14

30-00-00
11

AH

OPERATIONAL TEST OF
STANDBY DE ICING

OPT 10000-003
DEC14

30-00-00
OPT 10000-003

2-400

PAGE
11
DEC 01/14

30-00-00

OPERATIONAL TEST OF
DE-ICING CYCLES

OPT 10010-003
1

DEC14

ZONING DATA
___________
ZONE

: 210

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

GSE

: 01 COMPRESSOR

___
MEN

_________
MAN-HOURS

PUBLICATION
___________
JIC
JIC
JIC
JIC

: OPENING AND CLOSING OF


HINGED ENGINE COWLS
: DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY
: READING OF MFC
MAINTENANCE MEMORY
: ERASURE OF MFC
MAINTENANCE MEMORY

AH

54-00-00-OAC-10000
24-46-00-EAD-10000
45-13-00-RDG-10000
45-13-00-RON-10000

30-00-00
OPT 10010-003
2-400 PAGE
1
DEC 01/14

30-00-00

OPERATIONAL TEST OF
DE-ICING CYCLES

001

OPT 10010-003
2

DEC14

___________________________________
OPENING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000

002

ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


___________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

003

______________________
CHECK
OF MFC OPERATION
1. ON PANEL 25VU, CHECK THAT THE FOLLOWING
PUSHBUTTON SWITCHES ARE PRESSED
(OFF LEGENDS ARE OFF):
6UA1
6UA2
7UA1
7UA2

004

MFC/1B/FAULT/OFF
MFC/2B/FAULT/OFF
MFC/1A/FAULT/OFF
MFC/2A/FAULT/OFF

___________________________________
OPERATIONAL
TEST OF DE-ICING CYCLES
REF. FIG. 301100-OPT-00100
301100-OPT-00110
306100-OPT-00110
1. TO PERFORM TEST, CONNECT GROUND AIR PRESSURIZATION UNIT 4 BARS (58 PSI) (60 L/SEC)
TO LEFT REGULATOR VALVE TEST PORT 1.
NOTE : THIS TEST CAN BE PERFORMED ALSO WITH
ROTATING ENGINE. ENGINE COWLS CLOSED.
AFTER AN ENGINE REPLACEMENT, PERFORM
TEST DURING ENGINE ADJUSTMENT AT
RUN-UP.
2. ON PANEL 702VU,
PLACE SWITCH WEIGHT ON WHEELS IN FLT
POSITION.
*** CONTINUED ***
AH

30-00-00
OPT 10010-003
2-400 PAGE
2
DEC 01/14

30-00-00

OPERATIONAL TEST OF
DE-ICING CYCLES

OPT 10010-003
3

DEC14

3. ON PANEL 24VU,
A. CHECK THAT AFR AIR BLEED PUSHBUTTON
SWITCH (2) IS PRESSED :
-FAULT LEGEND OFF,
-OFF LEGEND OFF.
B. PRESS MODE SEL/AUTO PUSHBUTTON
SWITCH (5) :
-FAULT LEGEND OFF,
-MAN LEGEND ON.
C. PRESS AIRFRAME PUSHBUTTON SWITCH (3):
-FAULT LEGEND OFF,
-ON LEGEND ON.
4. ON PANEL 402VU,
CHECK THAT DE ICING ANNUNCIATOR (4) IS ON.
5. WAIT 60S, NO WARNINGS MUST APPEAR.
- CHECK VISUALLY DE-ICER INFLATING.
6. ON PANEL 24VU,
A. PRESS ANTI ICING/MODE SEL SAT<-10C
PUSHBUTTON SWITCH (3)
(FIG. 306100-OPT-00100) :
-ON LEGEND ON.
B. PRESS MODE SEL PUSHBUTTON SWITCH (1):
-SLOW LEGEND ON.
7. WAIT 3MN, NO WARNINGS MUST APPEAR.
- CHECK VISUALLY DE-ICER INFLATING.
8. ON PANEL 24VU,
A. RELEASE ANTI ICING/MODE SEL SAT<-10C
PUSHBUTTON SWITCH (3)
*** CONTINUED ***
AH

30-00-00
OPT 10010-003
2-400 PAGE
3
DEC 01/14

30-00-00

OPERATIONAL TEST OF
DE-ICING CYCLES

OPT 10010-003
4

DEC14

(FIG. 306100-OPT-00100) :
-ON LEGEND OFF.
B. PRESS MODE SEL PUSHBUTTON SWITCH (1):
-SLOW LEGEND OFF.
C. RELEASE AIRFRAME PUSHBUTTON SWITCH (3):
-FAULT LEGEND OFF,
-ON LEGEND OFF.
D. RELEASE MODE SEL/AUTO PUSHBUTTON
SWITCH (5) :
-FAULT LEGEND OFF,
-MAN LEGEND OFF.
9. ON PANEL 402VU,
CHECK THAT DE ICING ANNUNCIATOR (4)IS OFF
10.ON PANEL 21VU,
OPEN THE FOLLOWING CIRCUIT BREAKERS :
3FL1 ADS/ADC1 EMER SPLY
4UA1 MFC/1A AUX/ADC1 HOT SPLY
11.ON PANEL 24VU,
ON MODE SEL/AUTO PUSHBUTTON SWITCH(5):
-FAULT LEGEND COMES ON AFTER 5S,
-MAN LEGEND OFF.
12.FOLLOWING WARNINGS APPEAR :
- ON CAP, ANTI ICING ANNUNCIATOR COMES ON,
- CAUTION ANNUNCIATORS COME ON,
- SINGLE CHIME SOUNDS.
13.ON PANEL 21VU,
CLOSE THE CIRCUIT BREAKERS PREVIOUSLY OPENED
14.WARNINGS DISAPPEAR.
15.ON PANEL 21VU,
OPEN (3FL2) ADS/ADC 2 CIRCUIT BREAKER.
*** CONTINUED ***
AH

30-00-00
OPT 10010-003
2-400 PAGE
4
DEC 01/14

30-00-00

OPERATIONAL TEST OF
DE-ICING CYCLES

OPT 10010-003
5

DEC14

16.ON PANEL 24VU,


ON MODE SEL/AUTO PUSHBUTTON SWITCH (5):
-FAULT LEGEND COMES ON AFTER 5S,
-MAN LEGEND OFF.
17.FOLLOWING WARNINGS APPEAR :
- ON CAP, ANTI ICING ANNUNCIATOR COMES ON,
- CAUTION ANNUNCIATORS COME ON,
- SINGLE CHIME SOUNDS.
18.ON PANEL 21VU,
CLOSE CIRCUIT BREAKER PREVIOUSLY OPENED.
19.WARNINGS DISAPPEAR.
20.ON PANEL 702VU,
PLACE SWITCH WEIGHT ON WHEELS IN NORM
POSITION.
21.DISCONNECT GROUND AIR PRESSURIZATION UNIT
OR SHUTT OFF ENGINE.
22.INSTALL PROTECTIVE PLUG ON REGULATOR
VALVE TEST PORT.
NOTE : BY MEANS OF THE PROCEDURE BELLOW MAKE
SURE THAT THE FOLLOWING FAILURE ARE
MEMORIZED IN MISCELANEOUS 1 MFC
MAINTENANCE MEMORY :
- ADC 1 OR ADC 1 & 2 SWITCHES DISAGREE
- ADC 2 OR ADC 1 & 2 SWITCHES DISAGREE
005

_________________________________
READING
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RDG-10000

006

_________________________________
ERASURE
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RON-10000
*** CONTINUED ***
AH

30-00-00
OPT 10010-003
2-400 PAGE
5
DEC 01/14

30-00-00

OPERATIONAL TEST OF
DE-ICING CYCLES

007

OPT 10010-003
6

DEC14

DE-ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


______________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

008

________
CLOSE-UP
1. MAKE CERTAIN THAT WORKING AREA IS CLEAN AND
CLEAR OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
2. CLOSE ENGINE COWL 435AL.
3. REMOVE ACCESS PLATFORMS.

009

___________________________________
CLOSING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000
*****

AH

E N D

O F

T E X T

*****

30-00-00
OPT 10010-003
2-400 PAGE
6
DEC 01/14

30-00-00
7

AH

TEST COUPLING - PRESSURE


REGULATOR AND SHUT-OFF
VALVE

OPT 10010-003
DEC14

30-00-00
OPT 10010-003

2-400

PAGE
7
DEC 01/14

30-00-00
8

AH

CONTROLS AND INDICATING


WING/ENGINE DE ICING

OPT 10010-003
DEC14

30-00-00
OPT 10010-003

2-400

PAGE
8
DEC 01/14

30-00-00
9

AH

CONTROLS AND INDICATING


OF PROPELLER ANTI ICING

OPT 10010-003
DEC14

30-00-00
OPT 10010-003

2-400

PAGE
9
DEC 01/14

30-00-00

OPERATIONAL TEST OF
DE-ICING CYCLES

OPT 10010-004
1

DEC14

ZONING DATA
___________
ZONE

: 210

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

GSE

: 01 COMPRESSOR

___
MEN

_________
MAN-HOURS

PUBLICATION
___________
JIC
JIC
JIC
JIC

: OPENING AND CLOSING OF


HINGED ENGINE COWLS
: DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY
: READING OF MFC
MAINTENANCE MEMORY
: ERASURE OF MFC
MAINTENANCE MEMORY

AH

54-00-00-OAC-10000
24-46-00-EAD-10000
45-13-00-RDG-10000
45-13-00-RON-10000

30-00-00
OPT 10010-004
2-400 PAGE
1
DEC 01/14

30-00-00

OPERATIONAL TEST OF
DE-ICING CYCLES

001

OPT 10010-004
2

DEC14

___________________________________
OPENING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000

002

ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


___________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

003

______________________
CHECK
OF MFC OPERATION
1. ON PANEL 25VU, CHECK THAT THE FOLLOWING
PUSHBUTTON SWITCHES ARE PRESSED
(OFF LEGENDS ARE OFF):
6UA1
6UA2
7UA1
7UA2

004

MFC/1B/FAULT/OFF
MFC/2B/FAULT/OFF
MFC/1A/FAULT/OFF
MFC/2A/FAULT/OFF

___________________________________
OPERATIONAL
TEST OF DE-ICING CYCLES
REF. FIG. 301100-OPT-00100
301100-OPT-00110
306100-OPT-00110
1. TO PERFORM TEST, CONNECT GROUND AIR PRESSURIZATION UNIT 4 BARS (58 PSI) (60 L/SEC)
TO LEFT REGULATOR VALVE TEST PORT 1.
NOTE : THIS TEST CAN BE PERFORMED ALSO WITH
ROTATING ENGINE. ENGINE COWLS CLOSED.
AFTER AN ENGINE REPLACEMENT, PERFORM
TEST DURING ENGINE ADJUSTMENT AT
RUN-UP.
2. ON PANEL 702VU,
PLACE SWITCH WEIGHT ON WHEELS IN FLT
POSITION.
*** CONTINUED ***
AH

30-00-00
OPT 10010-004
2-400 PAGE
2
DEC 01/14

30-00-00

OPERATIONAL TEST OF
DE-ICING CYCLES

OPT 10010-004
3

DEC14

3. ON PANEL 24VU,
A. CHECK THAT AFR AIR BLEED PUSHBUTTON
SWITCH (2) IS PRESSED :
-FAULT LEGEND OFF,
-OFF LEGEND OFF.
B. PRESS MODE SEL/AUTO PUSHBUTTON
SWITCH (5) :
-FAULT LEGEND OFF,
-MAN LEGEND ON.
C. PRESS AIRFRAME PUSHBUTTON SWITCH (3):
-FAULT LEGEND OFF,
-ON LEGEND ON.
4. ON PANEL 402VU,
CHECK THAT DE ICING ANNUNCIATOR (4) IS ON.
5. WAIT 60S, NO WARNINGS MUST APPEAR.
- CHECK VISUALLY DE-ICER INFLATING.
6. ON PANEL 24VU,
A. PRESS ANTI ICING/MODE SEL SAT<-10C
PUSHBUTTON SWITCH (3)
(FIG. 306100-OPT-00100) :
-ON LEGEND ON.
B. PRESS MODE SEL PUSHBUTTON SWITCH (1):
-SLOW LEGEND ON.
7. WAIT 3MN, NO WARNINGS MUST APPEAR.
- CHECK VISUALLY DE-ICER INFLATING.
8. ON PANEL 24VU,
A. RELEASE ANTI ICING/MODE SEL SAT<-10C
PUSHBUTTON SWITCH (3)
*** CONTINUED ***
AH

30-00-00
OPT 10010-004
2-400 PAGE
3
DEC 01/14

30-00-00

OPERATIONAL TEST OF
DE-ICING CYCLES

OPT 10010-004
4

DEC14

(FIG. 306100-OPT-00100) :
-ON LEGEND OFF.
B. PRESS MODE SEL PUSHBUTTON SWITCH (1):
-SLOW LEGEND OFF.
C. RELEASE AIRFRAME PUSHBUTTON SWITCH (3):
-FAULT LEGEND OFF,
-ON LEGEND OFF.
D. RELEASE MODE SEL/AUTO PUSHBUTTON
SWITCH (5) :
-FAULT LEGEND OFF,
-MAN LEGEND OFF.
9. ON PANEL 402VU,
CHECK THAT DE ICING ANNUNCIATOR (4)IS OFF
10.ON PANEL 21VU,
OPEN THE FOLLOWING CIRCUIT BREAKERS :
3FL1 ADS/ADC1 EMER SPLY
4UA1 MFC/1A AUX/ADC1 HOT SPLY
11.ON PANEL 24VU,
ON MODE SEL/AUTO PUSHBUTTON SWITCH(5):
-FAULT LEGEND COMES ON AFTER 5S,
-MAN LEGEND OFF.
12.FOLLOWING WARNINGS APPEAR :
- ON CAP, ANTI ICING ANNUNCIATOR COMES ON,
- CAUTION ANNUNCIATORS COME ON,
- SINGLE CHIME SOUNDS.
13.ON PANEL 21VU,
CLOSE THE CIRCUIT BREAKERS PREVIOUSLY OPENED
14.WARNINGS DISAPPEAR.
15.ON PANEL 21VU,
OPEN (3FL2) ADS/ADC 2 CIRCUIT BREAKER.
*** CONTINUED ***
AH

30-00-00
OPT 10010-004
2-400 PAGE
4
DEC 01/14

30-00-00

OPERATIONAL TEST OF
DE-ICING CYCLES

OPT 10010-004
5

DEC14

16.ON PANEL 24VU,


ON MODE SEL/AUTO PUSHBUTTON SWITCH (5):
-FAULT LEGEND COMES ON AFTER 5S,
-MAN LEGEND OFF.
17.FOLLOWING WARNINGS APPEAR :
- ON CAP, ANTI ICING ANNUNCIATOR COMES ON,
- CAUTION ANNUNCIATORS COME ON,
- SINGLE CHIME SOUNDS.
18.ON PANEL 21VU,
CLOSE CIRCUIT BREAKER PREVIOUSLY OPENED.
19.WARNINGS DISAPPEAR.
20.ON PANEL 702VU,
PLACE SWITCH WEIGHT ON WHEELS IN NORM
POSITION.
21.DISCONNECT GROUND AIR PRESSURIZATION UNIT
OR SHUTT OFF ENGINE.
22.INSTALL PROTECTIVE PLUG ON REGULATOR
VALVE TEST PORT.
NOTE : BY MEANS OF THE PROCEDURE BELLOW MAKE
SURE THAT THE FOLLOWING FAILURE ARE
MEMORIZED IN MISCELANEOUS 1 MFC
MAINTENANCE MEMORY :
- ADC 1 OR ADC 1 & 2 SWITCHES DISAGREE
- ADC 2 OR ADC 1 & 2 SWITCHES DISAGREE
005

_________________________________
READING
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RDG-10000

006

_________________________________
ERASURE
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RON-10000
*** CONTINUED ***
AH

30-00-00
OPT 10010-004
2-400 PAGE
5
DEC 01/14

30-00-00

OPERATIONAL TEST OF
DE-ICING CYCLES

007

OPT 10010-004
6

DEC14

DE-ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


______________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

008

________
CLOSE-UP
1. MAKE CERTAIN THAT WORKING AREA IS CLEAN AND
CLEAR OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
2. CLOSE ENGINE COWL 435AL.
3. REMOVE ACCESS PLATFORMS.

009

___________________________________
CLOSING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000
*****

AH

E N D

O F

T E X T

*****

30-00-00
OPT 10010-004
2-400 PAGE
6
DEC 01/14

30-00-00
7

AH

TEST COUPLING - PRESSURE


REGULATOR AND SHUT-OFF
VALVE

OPT 10010-004
DEC14

30-00-00
OPT 10010-004

2-400

PAGE
7
DEC 01/14

30-00-00
8

AH

CONTROLS AND INDICATING


WING/ENGINE DE ICING

OPT 10010-004
DEC14

30-00-00
OPT 10010-004

2-400

PAGE
8
DEC 01/14

30-00-00
9

AH

CONTROLS AND INDICATING


OF PROPELLER ANTI ICING

OPT 10010-004
DEC14

30-00-00
OPT 10010-004

2-400

PAGE
9
DEC 01/14

30-00-00

OPERATIONAL TEST OF
DE-ICING CYCLES

OPT 10010-005
1

DEC14

ZONING DATA
___________
ZONE

: 210

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

GSE

: 01 COMPRESSOR

___
MEN

_________
MAN-HOURS

PUBLICATION
___________
JIC
JIC
JIC
JIC
JIC

: PRINCIPLE OF CDS USE


(DISPLAY UNITS
EXPLORATION)
: OPENING AND CLOSING OF
HINGED ENGINE COWLS
: DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY
: READING OF MFC
MAINTENANCE MEMORY
: ERASURE OF MFC
MAINTENANCE MEMORY

AH

31-63-00-PRO-10000
54-00-00-OAC-10000
24-46-00-EAD-10000
45-13-00-RDG-10000
45-13-00-RON-10000

30-00-00
OPT 10010-005
2-400 PAGE
1
DEC 01/14

30-00-00

OPERATIONAL TEST OF
DE-ICING CYCLES

001

OPT 10010-005
2

DEC14

PRINCIPLE OF CDS USE (DISPLAY UNITS


___________________________________
EXPLORATION)
____________
(TO USE ONLY IF NEEDED)
_______________________
SEE JOB INSTRUCTION CARD
316300-PRO-10000
NOTE: PROCEDURE TO USE ONLY IF NEEDED.
THIS PROCEDURE DESCRIBES LOCATION AND
MANAGEMENT OF THE DIFFERENT DISPLAY
WINDOWS PROVIDED BY THE THREE FORMATS
(PFD, EWD, MFD) PROPOSED ON THE FIVE
DISPLAY UNITS (DU).

002

___________________________________
OPENING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000

003

ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


___________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

004

______________________
CHECK
OF MFC OPERATION
1. ON PANEL 25VU, CHECK THAT THE FOLLOWING
PUSHBUTTON SWITCHES ARE PRESSED
(OFF LEGENDS ARE OFF):
6UA1
6UA2
7UA1
7UA2

005

MFC/1B/FAULT/OFF
MFC/2B/FAULT/OFF
MFC/1A/FAULT/OFF
MFC/2A/FAULT/OFF

___________________________________
OPERATIONAL
TEST OF DE-ICING CYCLES
REF. FIG. 301100-OPT-00100
301100-OPT-00110
306100-OPT-00110
*** CONTINUED ***
AH

30-00-00
OPT 10010-005
2-400 PAGE
2
DEC 01/14

30-00-00

OPERATIONAL TEST OF
DE-ICING CYCLES

OPT 10010-005
3

DEC14

1. TO PERFORM TEST, CONNECT GROUND AIR PRESSURIZATION UNIT 4 BARS (58 PSI) (60 L/SEC)
TO LEFT REGULATOR VALVE TEST PORT 1.
NOTE : THIS TEST CAN BE PERFORMED ALSO WITH
ROTATING ENGINE. ENGINE COWLS CLOSED.
AFTER AN ENGINE REPLACEMENT, PERFORM
TEST DURING ENGINE ADJUSTMENT AT
RUN-UP.
2. ON PANEL 702VU,
PLACE SWITCH WEIGHT ON WHEELS IN FLT
POSITION.
3. ON PANEL 24VU,
A. CHECK THAT AFR AIR BLEED PUSHBUTTON
SWITCH (2) IS PRESSED :
- FAULT LEGEND OFF,
- OFF LEGEND OFF.
B. PRESS MODE SEL/AUTO PUSHBUTTON
SWITCH (5) :
- FAULT LEGEND OFF,
- MAN LEGEND ON.
- ON EWD, IN ALERT WINDOW, A-ICING AUTO
MESSAGE APPEARS.
C. PRESS AIRFRAME PUSHBUTTON SWITCH (3):
- FAULT LEGEND OFF,
- ON LEGEND ON.
- ON MFD, IN TEMPORARY SELECTION WINDOW,
CYAN AIRFRAME MESSAGE IS DISPLAYED.
4. WAIT 60S, NO WARNINGS MUST APPEAR.
- CHECK VISUALLY DE-ICER INFLATING.
5. ON PANEL 24VU,
A. PRESS ANTI ICING/MODE SEL SAT<-10C
*** CONTINUED ***
AH

30-00-00
OPT 10010-005
2-400 PAGE
3
DEC 01/14

30-00-00

OPERATIONAL TEST OF
DE-ICING CYCLES

OPT 10010-005
4

DEC14

PUSHBUTTON SWITCH (3)


(FIG. 306100-OPT-00100) :
- ON LEGEND ON.
B. PRESS MODE SEL PUSHBUTTON SWITCH (1):
- SLOW LEGEND ON.
6. WAIT 3MN, NO WARNINGS MUST APPEAR.
- CHECK VISUALLY DE-ICER INFLATING.
7. ON PANEL 24VU,
A. RELEASE ANTI ICING/MODE SEL SAT<-10C
PUSHBUTTON SWITCH (3)
(FIG. 306100-OPT-00100) :
- ON LEGEND OFF.
B. PRESS MODE SEL PUSHBUTTON SWITCH (1):
- SLOW LEGEND OFF.
C. RELEASE AIRFRAME PUSHBUTTON SWITCH (3):
- FAULT LEGEND OFF,
- ON LEGEND OFF.
- ON MFD, IN TEMPORARY SELECTION WINDOW,
AIRFRAME MESSAGE DISAPPEARS.
D. RELEASE MODE SEL/AUTO PUSHBUTTON
SWITCH (5) :
- FAULT LEGEND OFF,
- MAN LEGEND OFF.
- ON EWD, IN ALERT WINDOW, A-ICING AUTO
MESSAGE DISAPPEARS.
8. ON PANEL 21VU,
OPEN THE FOLLOWING CIRCUIT BREAKERS :
3FL1 PRIM REF/ADC 1/ICP CAPT EMER SPLY
4UA1 MFC/1A AUX/ADC1 HOT SPLY
9. ON PANEL 24VU,
ON MODE SEL/AUTO PUSHBUTTON SWITCH (5):
*** CONTINUED ***
AH

30-00-00
OPT 10010-005
2-400 PAGE
4
DEC 01/14

30-00-00

OPERATIONAL TEST OF
DE-ICING CYCLES

OPT 10010-005
5

DEC14

- FAULT LEGEND COMES ON AFTER 5S,


- MAN LEGEND OFF.
10.FOLLOWING WARNINGS APPEAR :
- ON EWD, IN ALERT WINDOW, A-ICING AUTO
MESSAGE IS DISPLAYED.
- MASTER CAUTION ANNUNCIATORS COME ON,
- SINGLE CHIME SOUNDS.
11.ON PANEL 21VU,
CLOSE THE CIRCUIT BREAKERS PREVIOUSLY OPENED
12.WARNINGS DISAPPEAR.
13.ON PANEL 21VU,
OPEN THE FOLLOWING CIRCUIT BREAKER:
3FL2
PRIM REF/ADC 2 FLT SPLY/ICP F/O
14.ON PANEL 24VU,
ON MODE SEL/AUTO PUSHBUTTON SWITCH (5):
- FAULT LEGEND COMES ON AFTER 5S,
- MAN LEGEND OFF.
15.FOLLOWING WARNINGS APPEAR :
- ON EWD, IN ALERT WINDOW, A-ICING AUTO
MESSAGE IS DISPLAYED
- MASTER CAUTION ANNUNCIATORS COME ON,
- SINGLE CHIME SOUNDS.
16.ON PANEL 21VU,
CLOSE CIRCUIT BREAKER PREVIOUSLY OPENED.
17.WARNINGS DISAPPEAR.
18.ON PANEL 702VU,
PLACE SWITCH WEIGHT ON WHEELS IN NORM
POSITION.
19.DISCONNECT GROUND AIR PRESSURIZATION UNIT
OR SHUTT OFF ENGINE.
*** CONTINUED ***
AH

30-00-00
OPT 10010-005
2-400 PAGE
5
DEC 01/14

30-00-00

OPERATIONAL TEST OF
DE-ICING CYCLES

OPT 10010-005
6

DEC14

20.INSTALL PROTECTIVE PLUG ON REGULATOR


VALVE TEST PORT.
NOTE : BY MEANS OF THE PROCEDURE BELLOW MAKE
SURE THAT THE FOLLOWING FAILURE ARE
MEMORIZED IN MISCELANEOUS 1 MFC
MAINTENANCE MEMORY :
- ADC 1 OR ADC 1 & 2 SWITCHES DISAGREE
- ADC 2 OR ADC 1 & 2 SWITCHES DISAGREE
006

_________________________________
READING
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RDG-10000

007

_________________________________
ERASURE
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RON-10000

008

DE-ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


______________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

009

________
CLOSE-UP
1. MAKE CERTAIN THAT WORKING AREA IS CLEAN AND
CLEAR OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
2. CLOSE ENGINE COWL 435AL.
3. REMOVE ACCESS PLATFORMS.

010

___________________________________
CLOSING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000
*****

AH

E N D

O F

T E X T

*****

30-00-00
OPT 10010-005
2-400 PAGE
6
DEC 01/14

30-00-00
7

AH

TEST COUPLING - PRESSURE


REGULATOR AND SHUT-OFF
VALVE

OPT 10010-005
DEC14

30-00-00
OPT 10010-005

2-400

PAGE
7
DEC 01/14

30-00-00
8

AH

CONTROLS AND INDICATING


WING/ENGINE DE ICING

OPT 10010-005
DEC14

30-00-00
OPT 10010-005

2-400

PAGE
8
DEC 01/14

30-00-00
9

AH

CONTROLS AND INDICATING


OF PROPELLER ANTI ICING

OPT 10010-005
DEC14

30-00-00
OPT 10010-005

2-400

PAGE
9
DEC 01/14

30-11-00

CHECK CORRECT OPERATION


OF ANTI ICE HORNS
CONTROLLER

CHK 10000-001
1

APR05

ZONING DATA
___________
ZONE
ACCESS

: 214
: 214BZ

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

___
MEN

_________
MAN-HOURS

PUBLICATION
___________
JIC

: DC AND AC EXTERNAL POWER


SUPPLY

AH

24-40-00-EAD-10000

30-11-00
CHK 10000-001
2-400 PAGE
1
APR 01/05

30-11-00

CHECK CORRECT OPERATION


OF ANTI ICE HORNS
CONTROLLER

001

CHK 10000-001
2

APR05

___________
PREPARATION
1. ON PANEL 122VU, MAKE SURE THAT THE FOLLOWING
CIRCUIT BREAKERS ARE CLOSED:
33DM
34DM

ANTI/DE ICING/HORNS CTL & IND/RUD &


L ELEV
ANTI/DE ICING/HORNS CTL & IND/AIL &
R ELEV

2. OPEN ACCESS DOOR 214BZ, TO GAIN ACCESS TO


CONTROLLERS 57DM AND 58DM LOCATED ON
SHELVES 93VU AND 94VU.
002

___________________________________________
ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000

003

FUNCTIONAL CHECK OF ANTI ICING HORNS


____________________________________
CONTROLERS
__________
REF. FIG. 301100-CHK-00100
1. BITE TEST
A. ON THE FRONT FACE OF THE CONTROLLER :
(1)PRESS TEST PUSHBUTTON SWTICH.
- TEST LEDS COME ON AND THEN GO OFF
AFTER 5 SECONDS.
(2)RELEASE TEST PUSHBUTTON SWITCH.
- IF ONE LED REMAINS ON, REPLACE
CONTROLLER.
NOTE : PERFORM TEST ON THE TWO CONTROLLERS.

004

______________________________________________
DE-ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000
*** CONTINUED ***
AH

30-11-00
CHK 10000-001
2-400 PAGE
2
APR 01/05

30-11-00

CHECK CORRECT OPERATION


OF ANTI ICE HORNS
CONTROLLER

005

CHK 10000-001
3

APR05

________
CLOSE-UP
1. MAKE CERTAIN THAT WORKING AREA IS CLEAN AND
CLEAR OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
2. CLOSE ACCESS DOOR 214BZ.
*****

AH

E N D

O F

T E X T

*****

30-11-00
CHK 10000-001
2-400 PAGE
3
APR 01/05

30-11-00
4

AH

CHECK OF ANTI ICE


HORN CONTROLLERS

CHK 10000-001
APR05

30-11-00
CHK 10000-001

2-400

PAGE
4
APR 01/05

30-11-00

FUNCTIONAL TEST OF
ELECTRICAL HEATERS
VALVES

FUT 10000-001
1

APR05

ZONING DATA
___________

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

___
MEN

_________
MAN-HOURS

PUBLICATION
___________
JIC

: DC AND AC EXTERNAL POWER


SUPPLY

AH

24-40-00-EAD-10000

30-11-00
FUT 10000-001
2-400 PAGE
1
APR 01/05

30-11-00

FUNCTIONAL TEST OF
ELECTRICAL HEATERS
VALVES

001

FUT 10000-001
2

APR05

___________
PREPARATION
ON PANEL 122VU,CHECK THAT FOLLOWING CIRCUIT
BREAKERS ARE CLOSED.
2DM : ANTI/DE ICING/ENG2 & AFR BOOTS B/
NORM SPLY & V HTG CTL
112DM : ANTI/DE ICING/AFR DE ICING VALVES
HTG SPLY

002

___________________________________________
ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000

003

FUNCTIONAL TEST OF DE-ICING VALVES ELECTRICAL


_____________________________________________
HEATING
_______
REF. FIG. 301100-FUT-00100
1. WARNING
DURING THE TESTS, THE HEATERS ARE ELECTRICALLY SUPPLIED, THEIR TEMPERATURE CAN
EXCEED 100 DEG.C.
AVOID ALL CONTACT WITH THE HEATERS TO
PREVENT BURNING HANDS. AT THE END OF THE
TESTS, WAIT FOR THE HEATERS TO COOL DOWN
BEFORE PERFORMING WORK ON THE HEATERS AND/OR
THE VALVES.
NOTE 1 : A THERMAL SWITCH PROTECTS THE HEATERS
FROM EXCESSIVE TEMPERATURE (140 DEG.C)
IN CASE OF OVERHEAT, POWER SUPPLY IS
CUT OFF AND AMMETER INDICATES A
VALUE OF APPROXIMATELY 0A. WHEN THE
TEMPERATURE DROPS TO 112 DEG.C, POWER
SUPPLY IS RESTORED.
NOTE 2 : MEASUREMENT PRINCIPLE
*** CONTINUED ***
AH

30-11-00
FUT 10000-001
2-400 PAGE
2
APR 01/05

FUNCTIONAL TEST OF
ELECTRICAL HEATERS
VALVES

30-11-00

FUT 10000-001
3

APR05

1) DURING THE TEST USE A CLIP TO


CONNECT AMMETER LEADS TO CIRCUIT
BREAKER OR PRESS AMMETER CONTACT
LEADS AGAINST CONTACT OF CIRCUIT
BREAKER TO OBTAIN A CLEAN CONTACT.
AC WILD GENERATION MUST BE DE-ENERGIZED ANYTIME AMMETER IS CONNECTED
OR DISCONNECTED (OPEN, SAFETY AND
TAG CIRCUIT BREAKER 2XB ACW BUS2
PWR SPLY LOCATED ON PANEL 126VU).
ACCORDING TO THE HEATER SUPPLY USE,
AMMETER COULD BE SELECTED ON ALTERNATING CURRENT (AC) OR DIRECT CURRENT (DC). POSITION TO SELECT IS
DEFINE ON TABLE.
2) AMMETER READING
TWO READING PRINCIPLES
A) COIL OF RELAY 128DM IS SUPPLIED:
AMMETER INDICATES NO VALUE (0A).
CURRENT DOES NOT REACH HEATERS
THUS NO CURRENT FLOWS THROUGH
CIRCUIT BREAKER.
B) COIL OF RELAY 128DM IS NOT SUPPLIED :
AMMETER INDICATES CURRENT SUPPLIED TO HEATERS. DE-ENERGIZATION OF RELAY ALLOWS CURRENT TO
PASS THROUGH HEATER TO GROUND.
2. ON PANEL 122VU,
- OPEN, SAFETY AND TAG THE FOLLOWING CIRCUIT
BREAKER :
2DM : ANTI/DE ICING/ENG2 & AFR-BOOTS B/
NORM SPLY & V HTG CTL.
112DM : ANTI/DE ICING/AFR DE ICING VALVES
HTG SPLY
4XB : ACW ELEC PWR/ACW BUS/CAUTION LT/
BUS2
- OPEN PANEL 122VU AND DISCONNECT WIRE
3011-3495 CONNECTED TO GROUND MODULE 118VG
*** CONTINUED ***
AH

30-11-00
FUT 10000-001
2-400 PAGE
3
APR 01/05

30-11-00

FUNCTIONAL TEST OF
ELECTRICAL HEATERS
VALVES

FUT 10000-001
4

APR05

- CLOSE CIRCUIT BREAKER 2DM.


3. ON PANEL 101VU,
MAKE CERTAIN THAT WARN SELECTOR SWITCH
IS IN NORM FLT POSITION.
4. ON PANEL 122VU,
CONNECT AMMETER TO THE FOLLOWING TERMINALS
OF CIRCUIT BREAKER 112DM ANTI/DE-ICING/AFR
DE-ICING VALVE HTG SPLY AND ACCORDING TO
THE TEMPERATURE (SAT) READ THE APPROXIMATE
VALUES :
____________________________________________
|
| SAT < 3 DEG.C | SAT > 3 DEG.C |
|__________|_______________|_______________|
|A1 AND A2 | 0,46 A DC
|
0
|
|B1 AND B2 | 0,23 A DC
|
0
|
|C1 AND C2 | 0,46 A DC
|
0
|
|__________|_______________|_______________|
5. ON PANEL 101VU,
PLACE THE WARN SELECTOR SWITCH IN VMO
POSITION .
PRESS AND HOLD 187WW WARN PTT PUSHBUTTON
SWITCH.
6. ON PANEL 122VU,
CONNECT AMMETER TO THE FOLLOWING TERMINALS
OF CIRCUIT BREAKER 112DM ANTI/DE-ICING/AFR
DE-ICING VALVE HTG SPLY AND ACCORDING TO
THE TEMPERATURE (SAT) READ THE APPROXIMATE
VALUES :
____________________________________________
|
| SAT < 3 DEG.C | SAT > 3 DEG.C |
|__________|_______________|_______________|
|A1 AND A2 |
0
| 0,46 A DC
|
|B1 AND B2 |
0
| 0,23 A DC
|
|C1 AND C2 |
0
| 0,46 A DC
|
|__________|_______________|_______________|
7. ON PANEL 101VU,
*** CONTINUED ***
AH

30-11-00
FUT 10000-001
2-400 PAGE
4
APR 01/05

30-11-00

FUNCTIONAL TEST OF
ELECTRICAL HEATERS
VALVES

FUT 10000-001
5

APR05

REALEASE 187WW WARN PTT PUSHBUTTON SWITCH.


PLACE THE WARN SELECTOR SWITCH IN
NORM FLT POSITION .
8. ON PANEL 121VU,
A. OPEN CIRCUIT BREAKER 20GB : L/G-BRK/WOW
SYS2
- INSPECTION POINTS AND VALUES READ ON
AMMETER ARE IDENTICAL THAT TO PARAGRAPH
4. OR 6. DEPENDING ON AMBIANT TEMPERATURE (>3C OR <3C).
CLOSE CIRCUIT BREAKER 20GB.
B. OPEN CIRCUIT BREAKER 21GB : L/G-BRK/WOW
SYS1
- INSPECTION POINTS AND VALUES READ ON
AMMETER ARE IDENTICAL THAT TO PARAGRAPH
4. OR 6. DEPENDING ON AMBIANT TEMPERATURE (>3C OR <3C).
CLOSE CIRCUIT BREAKER 21GB.
9. ON PANEL 122VU,
A. OPEN, SAFETY AND TAG THE FOLLOWING
CIRCUIT BREAKER :
2DM : ANTI/DE ICING/ENG2 & AFR-BOOTS B/
NORM SPLY & V HTG CTL.
B. CONNECT AMMETER TO THE FOLLOWING TERMINALS OF CIRCUIT BREAKER 112DM ANTI/DE
ICING/AFR DE-ICING VALVE HTG SPLY AND
READ THE APPROXIMATE VALUES :
_______________________________
| A1 AND A2 |
1
A AC |
| B1 AND B2 |
0,23 A DC |
| C1 AND C2 |
1
A AC |
|___________|_________________|
C. CONNECT WIRE 3011-3495 TO 118VG,
CLOSE CIRCUIT BREAKER 2DM,
*** CONTINUED ***
AH

30-11-00
FUT 10000-001
2-400 PAGE
5
APR 01/05

30-11-00

FUNCTIONAL TEST OF
ELECTRICAL HEATERS
VALVES

FUT 10000-001
6

APR05

DISCONNECT AMMETER.
D. CLOSE CIRCUIT BREAKERS 112DM, 2XB AND 4XB
004

________
CLOSE-UP
MAKE CERTAIN THAT WORKING AREA IS CLEAN AND
CLEAR OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.

005

______________________________________________
DE-ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000
*****

AH

E N D

O F

T E X T

*****

30-11-00
FUT 10000-001
2-400 PAGE
6
APR 01/05

30-11-00
7

AH

FUNCTIONAL TEST OF
ELECTRICAL HEATERS

FUT 10000-001
APR05

30-11-00
FUT 10000-001

2-400

PAGE
7
APR 01/05

30-11-00

OPERATIONAL TEST AND


VISUAL CHECK OF DE-ICER
BONDING

GVI 10000-001
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 210
435
: 435AL

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

GSE

: 01 ACCESS PLATFORM
01 COMPRESSOR

_________
MAN-HOURS

PUBLICATION
___________
JIC
JIC

: OPENING AND CLOSING OF


HINGED ENGINE COWLS
: DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY

AH

54-00-00-OAC-10000
24-46-00-EAD-10000

30-11-00
GVI 10000-001
2-400 PAGE
1
DEC 01/14

30-11-00

OPERATIONAL TEST AND


VISUAL CHECK OF DE-ICER
BONDING

001

GVI 10000-001
2

DEC14

___________
PREPARATION
1. INSTALL PLATFORM TO GAIN ACCESS TO PRESSURE
REGULATOR AND SHUT OFF VALVE 13DM.
2. OPEN ENGINE COWL 435AL.
3. INSTALL PLATFORMS TO GAIN ACCESS TO VARIOUS
DE-ICERS.

002

___________________________________
OPENING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000

003

ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


___________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

004

______________________
CHECK
OF MFC OPERATION
1. ON PANEL 25VU, CHECK THAT THE FOLLOWING
PUSHBUTTON SWITCHES ARE PRESSED
(OFF LEGENDS ARE OFF):
6UA1
6UA2
7UA1
7UA2

005

MFC/1B/FAULT/OFF
MFC/2B/FAULT/OFF
MFC/1A/FAULT/OFF
MFC/2A/FAULT/OFF

OPERATIONAL TEST AND VISUAL CHECK OF DE-ICER


____________________________________________
BONDING
_______
REF. FIG. 301100-OPT-00100,
301100-OPT-00110.
1. CONNECT COMPRESSOR 4 BARS (58 PSI) (60L/SEC)
TO LEFT ENGINE REGULATOR AND SHUT-OFF VALVE
TEST PLUG.
*** CONTINUED ***
AH

30-11-00
GVI 10000-001
2-400 PAGE
2
DEC 01/14

30-11-00

OPERATIONAL TEST AND


VISUAL CHECK OF DE-ICER
BONDING

GVI 10000-001
3

DEC14

2. APPLY AIR PRESSURE TO SYSTEM.


3. ON PANEL 702VU,
PLACE SWITCH WEIGHT ON WHEELS IN FLT
POSITION.
4. ON PANEL 24VU,
A. CHECK THAT AFR AIR BLEED PUSHBUTTON
SWITCH (20DM) IS PRESSED :
- FAULT LEGEND OFF,
- OFF LEGEND OFF.
B. PRESS AIR FRAME PUSHBUTTON SWITCH (7DM)
- FAULT LEGEND OFF,
- OFF LEGEND ON.
C. PRESS ENG1 (1DN) AND ENG2 (2DN) PUSHBUTTONS SWITCHES :
- FAULT LEGEND OFF,
- ON LEGEND ON.
5. ON PANEL 402VU,
CHECK THAT DE ICING INDICATOR (12DM) IS
ON.
6. WAIT DE ICING CYCLE, I.E. 60 SECONDS, NO
WARNINGS MUST BE APPEAR.
7. ON PANEL 24VU,
PRESS MODE SEL PUSHBUTTON SWITCH (6DM) :
- SLOW LEGEND ON .
8. WAIT DE ICING CYCLE, I.E. 240 SECONDS, NO
WARNINGS MUST BE APPEAR.
9. VISUALLY CHECK FOR ABSENCE OF SWELLING OR
UNSLICKING ALONG DE-ICERS SURFACE
10. ON PANEL 24VU,
*** CONTINUED ***
AH

30-11-00
GVI 10000-001
2-400 PAGE
3
DEC 01/14

30-11-00

OPERATIONAL TEST AND


VISUAL CHECK OF DE-ICER
BONDING

GVI 10000-001
4

DEC14

A. RELEASE AIRFRAME PUSHBUTTON SWITCH


(7DM) :
- FAULT LEGEND OFF,
- ON LEGEND OFF.
B. RELEASE ENG1 (1DN) AND ENG2 (2DN)
PUSHBUTTONS SWITCHES :
- FAULT LEGEND OFF,
- ON LEGEND OFF.
11. ON PANEL 402VU,
CHECK THAT DE ICING INDICATOR (12DM) IS
OFF.
12. ON PANEL 702VU,
PLACE SWITCH WEIGHT ON WHEELS ON NORM
POSITION.
13. SHUT DOWN PRESSURE IN SYSTEM.
14. DISCONNECT GROUND AIR PRESSURIZATION UNIT.
006

DE-ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


______________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

007

________
CLOSE-UP
1. MAKE CERTAIN THAT WORKING AREA IS CLEAN AND
CLEAR OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
2. CLOSE ENGINE COWL 435AL.
3. REMOVE ACCESS PLATFORMS.

*** CONTINUED ***


AH

30-11-00
GVI 10000-001
2-400 PAGE
4
DEC 01/14

30-11-00

OPERATIONAL TEST AND


VISUAL CHECK OF DE-ICER
BONDING

008

GVI 10000-001
5

DEC14

___________________________________
CLOSING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000
*****

AH

E N D

O F

T E X T

*****

30-11-00
GVI 10000-001
2-400 PAGE
5
DEC 01/14

30-11-00
6

AH

CONTROLS AND INDICATING


WING/ENGINE DE ICING

GVI 10000-001
DEC14

30-11-00
GVI 10000-001

2-400

PAGE
6
DEC 01/14

30-11-00
7

AH

TEST COUPLING - PRESSURE


REGULATOR AND SHUT-OFF
VALVE

GVI 10000-001
DEC14

30-11-00
GVI 10000-001

2-400

PAGE
7
DEC 01/14

30-11-00

OPERATIONAL TEST AND


VISUAL CHECK OF DE-ICER
BONDING

GVI 10000-002
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 210
435
: 435AL

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

GSE

: 01 ACCESS PLATFORM
01 COMPRESSOR

_________
MAN-HOURS

PUBLICATION
___________
JIC
JIC

: OPENING AND CLOSING OF


HINGED ENGINE COWLS
: DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY

AH

54-00-00-OAC-10000
24-46-00-EAD-10000

30-11-00
GVI 10000-002
2-400 PAGE
1
DEC 01/14

30-11-00

OPERATIONAL TEST AND


VISUAL CHECK OF DE-ICER
BONDING

001

GVI 10000-002
2

DEC14

___________
PREPARATION
1. INSTALL PLATFORM TO GAIN ACCESS TO PRESSURE
REGULATOR AND SHUT OFF VALVE 13DM.
2. OPEN ENGINE COWL 435AL.
3. INSTALL PLATFORMS TO GAIN ACCESS TO VARIOUS
DE-ICERS.

002

___________________________________
OPENING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000

003

ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


___________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

004

______________________
CHECK
OF MFC OPERATION
1. ON PANEL 25VU, CHECK THAT THE FOLLOWING
PUSHBUTTON SWITCHES ARE PRESSED
(OFF LEGENDS ARE OFF):
6UA1
6UA2
7UA1
7UA2

005

MFC/1B/FAULT/OFF
MFC/2B/FAULT/OFF
MFC/1A/FAULT/OFF
MFC/2A/FAULT/OFF

OPERATIONAL TEST AND VISUAL CHECK OF DE-ICER


____________________________________________
BONDING
_______
REF. FIG. 301100-OPT-00100,
301100-OPT-00110.
1. TO PERFORM TEST, CONNECT GROUND AIR PRESSURIZATION UNIT 4 BARS (58 PSI) (60L/SEC)
TO LEFT REGULATOR VALVE TEST PORT 1.
*** CONTINUED ***
AH

30-11-00
GVI 10000-002
2-400 PAGE
2
DEC 01/14

30-11-00

OPERATIONAL TEST AND


VISUAL CHECK OF DE-ICER
BONDING

GVI 10000-002
3

DEC14

2. APPLY AIR PRESSURE TO SYSTEM.


3. ON PANEL 702VU,
PLACE SWITCH WEIGHT ON WHEELS IN FLT
POSITION.
4. ON PANEL 24VU,
A. CHECK THAT AFR AIR BLEED PUSHBUTTON
SWITCH (20DM) IS PRESSED :
- FAULT LEGEND OFF,
- OFF LEGEND OFF.
B. PRESS AIR FRAME PUSHBUTTON SWITCH (7DM)
- FAULT LEGEND OFF,
- OFF LEGEND ON.
C. PRESS ENG1 (1DN) AND ENG2 (2DN) PUSHBUTTONS SWITCHES :
- FAULT LEGEND OFF,
- ON LEGEND ON.
5. ON PANEL 402VU,
CHECK THAT DE ICING INDICATOR (12DM) IS
ON.
6. WAIT DE ICING CYCLE, I.E. 60 SECONDS, NO
WARNINGS MUST BE APPEAR.
7. ON PANEL 24VU,
PRESS MODE SEL PUSHBUTTON SWITCH (6DM) :
- SLOW LEGEND ON .
8. WAIT DE ICING CYCLE, I.E. 240 SECONDS, NO
WARNINGS MUST BE APPEAR.
9. VISUALLY CHECK FOR ABSENCE OF SWELLING OR
UNSLICKING ALONG DE-ICERS SURFACE
10. ON PANEL 24VU,
*** CONTINUED ***
AH

30-11-00
GVI 10000-002
2-400 PAGE
3
DEC 01/14

30-11-00

OPERATIONAL TEST AND


VISUAL CHECK OF DE-ICER
BONDING

GVI 10000-002
4

DEC14

A. RELEASE AIRFRAME PUSHBUTTON SWITCH


(7DM) :
- FAULT LEGEND OFF,
- ON LEGEND OFF.
B. RELEASE ENG1 (1DN) AND ENG2 (2DN)
PUSHBUTTONS SWITCHES :
- FAULT LEGEND OFF,
- ON LEGEND OFF.
11. ON PANEL 402VU,
CHECK THAT DE ICING INDICATOR (12DM) IS
OFF.
12. ON PANEL 702VU,
PLACE SWITCH WEIGHT ON WHEELS ON NORM
POSITION.
13. SHUT DOWN PRESSURE IN SYSTEM.
14. DISCONNECT GROUND AIR PRESSURIZATION UNIT.
006

DE-ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


______________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

007

________
CLOSE-UP
1. MAKE CERTAIN THAT WORKING AREA IS CLEAN AND
CLEAR OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
2. CLOSE ENGINE COWL 435AL.
3. REMOVE ACCESS PLATFORMS.

*** CONTINUED ***


AH

30-11-00
GVI 10000-002
2-400 PAGE
4
DEC 01/14

30-11-00

OPERATIONAL TEST AND


VISUAL CHECK OF DE-ICER
BONDING

008

GVI 10000-002
5

DEC14

___________________________________
CLOSING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000
*****

AH

E N D

O F

T E X T

*****

30-11-00
GVI 10000-002
2-400 PAGE
5
DEC 01/14

30-11-00
6

AH

CONTROLS AND INDICATING


WING/ENGINE DE ICING

GVI 10000-002
DEC14

30-11-00
GVI 10000-002

2-400

PAGE
6
DEC 01/14

30-11-00
7

AH

TEST COUPLING - PRESSURE


REGULATOR AND SHUT-OFF
VALVE

GVI 10000-002
DEC14

30-11-00
GVI 10000-002

2-400

PAGE
7
DEC 01/14

30-11-00

OPERATIONAL TEST AND


VISUAL CHECK OF DE-ICER
BONDING

GVI 10000-003
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 210
435
: 435AL

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

GSE

: 01 ACCESS PLATFORM
01 COMPRESSOR

_________
MAN-HOURS

PUBLICATION
___________
JIC
JIC
JIC

: PRINCIPLE OF CDS USE


(DISPLAY UNITS
EXPLORATION)
: OPENING AND CLOSING OF
HINGED ENGINE COWLS
: DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY

AH

31-63-00-PRO-10000
54-00-00-OAC-10000
24-46-00-EAD-10000

30-11-00
GVI 10000-003
2-400 PAGE
1
DEC 01/14

30-11-00

OPERATIONAL TEST AND


VISUAL CHECK OF DE-ICER
BONDING

001

GVI 10000-003
2

DEC14

PRINCIPLE OF CDS USE (DISPLAY UNITS


___________________________________
EXPLORATION)
____________
(TO USE ONLY IF NEEDED)
_______________________
SEE JOB INSTRUCTION CARD
316300-PRO-10000
NOTE: PROCEDURE TO USE ONLY IF NEEDED.
THIS PROCEDURE DESCRIBES LOCATION AND
MANAGEMENT OF THE DIFFERENT DISPLAY
WINDOWS PROVIDED BY THE THREE FORMATS
(PFD, EWD, MFD) PROPOSED ON THE FIVE
DISPLAY UNITS (DU).

002

___________
PREPARATION
1. INSTALL PLATFORM TO GAIN ACCESS TO PRESSURE
REGULATOR AND SHUT OFF VALVE 13DM.
2. OPEN ENGINE COWL 435AL.
3. INSTALL PLATFORMS TO GAIN ACCESS TO VARIOUS
DE-ICERS.

003

___________________________________
OPENING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000

004

ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


___________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

005

______________________
CHECK
OF MFC OPERATION
1. ON PANEL 25VU, CHECK THAT THE FOLLOWING
PUSHBUTTON SWITCHES ARE PRESSED
(OFF LEGENDS ARE OFF):
*** CONTINUED ***
AH

30-11-00
GVI 10000-003
2-400 PAGE
2
DEC 01/14

30-11-00

OPERATIONAL TEST AND


VISUAL CHECK OF DE-ICER
BONDING

6UA1
6UA2
7UA1
7UA2
006

GVI 10000-003
3

DEC14

MFC/1B/FAULT/OFF
MFC/2B/FAULT/OFF
MFC/1A/FAULT/OFF
MFC/2A/FAULT/OFF

OPERATIONAL TEST AND VISUAL CHECK OF DE-ICER


____________________________________________
BONDING
_______
REF. FIG. 301100-OPT-00100,
301100-OPT-00110.
1. TO PERFORM TEST, CONNECT GROUND AIR PRESSURIZATION UNIT 4 BARS (58 PSI) (60L/SEC)
TO LEFT REGULATOR VALVE TEST PORT 1.
2. APPLY AIR PRESSURE TO SYSTEM.
3. ON PANEL 702VU,
PLACE SWITCH WEIGHT ON WHEELS IN FLT
POSITION.
4. A. ON PANEL 24VU, CHECK THAT AFR AIR BLEED
PUSHBUTTON SWITCH IS PRESSED :
- FAULT LEGEND OFF,
- OFF LEGEND OFF.
B. .ON PANEL 24VU, PRESS AIR FRAME
PUSHBUTTON SWITCH
- FAULT LEGEND OFF,
- ON LEGEND ON.
.ON MFD, IN TEMPORARY SELECTION WINDOW,
CYAN AIRFRAME MESSAGE IS DISPLAYED.
C. .ON PANEL 24VU PRESS ENG1 AND ENG2
PUSHBUTTONS SWITCHES :
- FAULT LEGEND OFF,
- ON LEGEND ON.
.ON MFD, IN TEMPORARY SELECTION WINDOW,
CYAN 1 ENG 2 MESSAGE IS DISPLAYED.
5. WAIT DE ICING

CYCLE, I.E. 60 SECONDS, NO


*** CONTINUED ***

AH

30-11-00
GVI 10000-003
2-400 PAGE
3
DEC 01/14

30-11-00

OPERATIONAL TEST AND


VISUAL CHECK OF DE-ICER
BONDING

GVI 10000-003
4

DEC14

WARNINGS MUST BE APPEAR.


6. ON PANEL 24VU,
PRESS MODE SEL PUSHBUTTON SWITCH :
- SLOW LEGEND ON .
7. WAIT DE ICING CYCLE, I.E. 240 SECONDS, NO
WARNINGS MUST BE APPEAR.
8. VISUALLY CHECK FOR ABSENCE OF SWELLING OR
UNSLICKING ALONG DE-ICERS SURFACE
9. A. .ON PANEL 24VU, RELEASE AIRFRAME
PUSHBUTTON SWITCH:
- FAULT LEGEND OFF,
- ON LEGEND OFF.
.ON MFD, IN TEMPORARY SELECTION WINDOW,
AIRFRAME MESSAGE DISAPPEARS.
B. .RELEASE ENG1 AND ENG2
PUSHBUTTONS SWITCHES :
- FAULT LEGEND OFF,
- ON LEGEND OFF.
.ON MFD, IN TEMPORARY SELECTION WINDOW,
1 ENG 2 MESSAGE DISAPPEARS.
10. ON PANEL 702VU,
PLACE SWITCH WEIGHT ON WHEELS ON NORM
POSITION.
11. SHUT DOWN PRESSURE IN SYSTEM.
12. DISCONNECT GROUND AIR PRESSURIZATION UNIT.
007

DE-ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


______________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

*** CONTINUED ***


AH

30-11-00
GVI 10000-003
2-400 PAGE
4
DEC 01/14

30-11-00

OPERATIONAL TEST AND


VISUAL CHECK OF DE-ICER
BONDING

008

GVI 10000-003
5

DEC14

________
CLOSE-UP
1. MAKE CERTAIN THAT WORKING AREA IS CLEAN AND
CLEAR OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
2. CLOSE ENGINE COWL 435AL.
3. REMOVE ACCESS PLATFORMS.

009

___________________________________
CLOSING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000
*****

AH

E N D

O F

T E X T

*****

30-11-00
GVI 10000-003
2-400 PAGE
5
DEC 01/14

30-11-00
6

AH

CONTROLS AND INDICATING


WING/ENGINE DE ICING

GVI 10000-003
DEC14

30-11-00
GVI 10000-003

2-400

PAGE
6
DEC 01/14

30-11-00
7

AH

TEST COUPLING - PRESSURE


REGULATOR AND SHUT-OFF
VALVE

GVI 10000-003
DEC14

30-11-00
GVI 10000-003

2-400

PAGE
7
DEC 01/14

30-11-00

OPERATIONAL TEST OF
AIRFOIL DE-ICING SYSTEM

OPT 10000-006
1

MAR15

ZONING DATA
___________
ZONE

ACCESS

: 310
435
510
610
: 435AL
512
612
851

445
445AL
514
614

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

GSE

: 06 ACCESS PLATFORM
01 STEP LADDER
01 COMPRESSOR

_________
MAN-HOURS

PUBLICATION
___________
JIC
JIC
JIC
JIC
JIC

: REMOVAL/INSTALLATION OF
LEADING EDGES
: OPENING AND CLOSING OF
HINGED ENGINE COWLS
: DC AND AC EXTERNAL POWER
SUPPLY
: READING OF MFC
MAINTENANCE MEMORY
: ERASURE OF MFC
MAINTENANCE MEMORY

AH

57-40-00-RAI-10000
54-00-00-OAC-10000
24-40-00-EAD-10000
45-13-00-RDG-10000
45-13-00-RON-10000

30-11-00
OPT 10000-006
2-400 PAGE
1
MAR 01/15

30-11-00

OPERATIONAL TEST OF
AIRFOIL DE-ICING SYSTEM

001

OPT 10000-006
2

MAR15

___________
PREPARATION
1. INSTALL PLATFORM SO AS TO HAVE ACCESS TO
FOLLOWING EQUIPMENTS :
A. ON ENGINE L AND R
. REGULATOR AND SHUT OFF VALVE 13DM AND
14DM.
B. ON WING L AND R
. DUAL DISTRIBUTOR VALVE 9DM, 10DM, 83DM
AND 84DM.
2. OPEN ACCESS DOOR 851 AND INSTALL STEP LADDER
SO AS TO HAVE ACCESS TO FOLLOWING EQUIPMENTS
A. TO HORIZONTAL STABILIZER DUAL DISTRIBUTOR
VALVE 11DM.
3. OPEN ENGINE PANELS 435AL (445AL).
4. REMOVE THE FOLLOWING LEADING EDGE TO ACCES
TO DUAL DISTRIBUTOR VALVES :
512 => VALVE 83DM
612 => VALVE 84DM
514 => VALVE 9DM
614 => VALVE 10DM
5. BY MEANS OF THE BELOW PROCEDURE CHECK IF
SYSTEM BOOTS FAILURE IS MEMORIZED IN
MFC MAINTENANCE MEMORY.

002

________________________
REMOVAL
OF LEADING EDGES
SEE JOB INSTRUCTION CARD
574000-RAI-10000

003

___________________________________
OPENING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000
*** CONTINUED ***
AH

30-11-00
OPT 10000-006
2-400 PAGE
2
MAR 01/15

30-11-00

OPERATIONAL TEST OF
AIRFOIL DE-ICING SYSTEM

004

OPT 10000-006
3

MAR15

___________________________________________
ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000

005

_________________________________
READING
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RDG-10000

006

_________________________________
ERASURE
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RON-10000
NOTE:THIS TASK MUST BE PERFORMED ONLY IF FAULTS
RELATIVE TO THE SYSTEM TO BE CHECKED HAVE
BEEN RECORDED BY THE MFC MAINTENANCE
MEMORY.

007

OPERATIONAL TEST OF AIRFOIL SURFACE ICE


_______________________________________
PROTECTION AND WARNINGS USING EACH
__________________________________
REGULATOR AND SHUTOFF VALVE
___________________________
REF. FIG. 301100-OPT-00100
REF. FIG. 301100-OPT-00110
TO PERFORM TEST, CONNECT COMPRESSOR 4 BARS
(58 PSI) (60 L/SEC) TO LEFT ENGINE REGULATOR
AND SHUT-OFF VALVE TEST PLUG.
NOTE: THIS TEST CAN BE PERFORMED ALSO WITH
ROTATING ENGINES.ENGINE COWLS CLOSED.
AFTER AN ENGINE REPLACEMENT,PERFORM
TEST DURING ENGINE ADJUSTMENT AT
RUN-UP.
1. ON PANEL 702VU,
PLACE SWITCH WEIGHT ON WHEELS IN FLT
POSITION.
*** CONTINUED ***
AH

30-11-00
OPT 10000-006
2-400 PAGE
3
MAR 01/15

30-11-00

OPERATIONAL TEST OF
AIRFOIL DE-ICING SYSTEM

OPT 10000-006
4

MAR15

2. ON PANEL 24VU, (DE ICING PANEL)


A. CHECK THAT AFR AIR BLEED
PUSHBUTTON SWITCH (2) IS PRESSED:
- FAULT LEGEND OFF,
- OFF LEGEND OFF.
B. PRESS MODE SEL/AUTO PUSHBUTTON
SWITCH (5):
- FAULT LEGEND OFF,
- MAN LEGEND ON.
C. CHECK THAT MODE SEL PUSHBUTTON
SWITCH (1) IS RELEASED (OUT):
- SLOW LEGEND OFF.
3. PRESS AIR FRAME PUSHBUTTON SWITCH (3):
- FAULT LEGEND OFF,
- ON LEGEND ON.
4. ON PANEL 402VU,
CHECK THAT DE ICING ANNUNCIATOR (4) IS ON.
5. WAIT FOR DE ICING CYCLE, I.E. 60 SECONDS.
NO ALERTS MUST APPEAR.
6. ON PANEL 24VU,
PRESS MODE SEL PUSHBUTTON SWITCH (1):
- SLOW LEGEND ON.
7. WAIT FOR DE ICING CYCLE I.E. 180 SECONDS.
NO ALERTS MUST APPEAR.
NOTE: PERFORM THIS TEST ONLY WHEN THIS TEST IS
PERFORMED WITH A COMPRESSOR.
CHECK MANUALLY AND AURALLY FOR AIR
LEAKAGE OF REGULATOR AND SHUTOFF VALVES
(5) AND(8) AT LEVEL OF REGULATION BELLOWS
(12) LOCATED UNDER THE VALVES, AND FOR
AIR LEAKAGE OF DUAL DISTRIBUTOR VALVES,
(1),(2),(3),(4),(9) AND (10) AND AIR JET
*** CONTINUED ***
AH

30-11-00
OPT 10000-006
2-400 PAGE
4
MAR 01/15

30-11-00

OPERATIONAL TEST OF
AIRFOIL DE-ICING SYSTEM

OPT 10000-006
5

MAR15

PUMPS (13) LOCATED AT THE UPPER END OF


THE VALVES.
DURING THE DE ICERS BOOTS A AND B INFLATE
CHECK VISUALY ON THE ALL DE ICERS
SURFACE THE ABSENCE OF FLATULENCE OR
UNGLUING.
8. ON PANEL 24VU,
RELEASE MODE SEL PUSHBUTTON SWITCH (1):
- SLOW LEGEND OFF.
9. ON PANEL 25VU,
RELEASE (7UA1) MFC/1A AND (6UA2) MFC/2B
PUSHBUTTON SWITCHES (8) AND (11):
- FAULT LEGEND OFF,
- OFF LEGEND ON.
10.WAIT FOR DE ICING CYCLE, I.E. 60 SECONDS.
NO ALERTS MUST APPEAR.
11.ON PANEL 24VU,
PRESS MODE SEL PUSHBUTTON SWITCH (1):
- SLOW LEGEND ON.
12.WAIT FOR DE CING CYCLE I.E. 180 SECONDS.
NO ALERTS MUST APPEAR.
13.ON PANEL 24VU,
RELEASE PUSHBUTTON SWITCH (1):
- SLOW LEGEND OFF.
14.ON PANEL 25VU,
PRESS (7UA1) MFC/1A AND (6UA2) MFC/2B
PUSHBUTTON SWITCHES (8) AND (11):
- FAULT LEGEND OFF,
- OFF LEGEND OFF.
15.ON PANEL 25VU,
RELEASE (6UA1) MFC/1B AND (7UA2) MFC/2A
PUSHBUTTON SWITCHES (8) AND (10):
- FAULT LEGEND OFF,
*** CONTINUED ***
AH

30-11-00
OPT 10000-006
2-400 PAGE
5
MAR 01/15

30-11-00

OPERATIONAL TEST OF
AIRFOIL DE-ICING SYSTEM

OPT 10000-006
6

MAR15

- OFF LEGEND ON.


16.WAIT FOR DE ICING CYCLE I.E. 60 SECONDS.
NO ALERTS MUST APPEAR.
17.ON PANEL 24VU,
PRESS MOD SEL PUSHBUTTON SWITCH (1):
- SLOW LEGEND ON.
18.WAIT FOR DE ICING CYCLE I.E. 180 SECONDS.
NO ALERTS MUST APPEAR.
19.ON PANEL 24VU,
RELEASE PUSHBUTTON SWITCH (1):
- SLOW LEGEND OFF.
20.ON PANEL 25VU,
PRESS (6UA1) MFC/1B AND (7UA2) MFC/2A
PUSHBUTTON SWITCHES (9) AND (10):
- FAULT LEGEND OFF,
- OFF LEGEND OFF.
21.ON PANEL 702VU,
PLACE WEIGHT ON WHEELS SWITCH ON NORM.
22.DISCONNECT GROUND AIR PRESSURIZATION UNIT
OR SHUT OFF ENGINE.
NOTE: USING THE BELOW PROCEDURE MAKE SURE THAT
THE FOLLOWING FAILURE ARE NOT MEMORIZED IN THE
MFC MAINTENANCE MEMORY
BOOTS MEMORY :
- LEFT WING BOOT A FAULT
- RIGHT WING BOOT A FAULT
- LEFT WING BOOT B FAULT
- RIGHT WING BOOT B FAULT
- LEFT MEDIAN WING BOOT A FAULT
- RIGHT MEDIAN WING BOOT A FAULT
- LEFT MEDIAN WING BOOT B FAULT
- RIGHT MEDIAN WING BOOT B FAULT
- LEFT EMPENAGE BOOT A FAULT
*** CONTINUED ***
AH

30-11-00
OPT 10000-006
2-400 PAGE
6
MAR 01/15

30-11-00

OPERATIONAL TEST OF
AIRFOIL DE-ICING SYSTEM

OPT 10000-006
7

MAR15

- LEFT EMPENAGE BOOT B FAULT


MISCELANEOUS 2 MEMORY :
- FIN OPTIONAL BOOTS A FAULT
- FIN OPTIONAL BOOTS B FAULT
MISCELANEOUS 4 MEMORY :
- RIGHT EMPENAGE BOOT A FAULT
- RIGHT EMPENAGE BOOT B FAULT
008

_________________________________
READING
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RDG-10000

009

OPERATIONAL TEST OF AIRFOIL SURFACE ICE


_______________________________________
PROTECTION AND WARNINGS USING EACH
__________________________________
REGULATOR AND SHUTOFF VALVE
___________________________
REF. FIG. 301100-OPT-00100, 301100-OPT-00110,
301100-CHK-00110
1. ON PANEL 702VU:
PLACE SWITCH WEIGHT ON WHEELS IN FLT
POSITION.
2. PLACE THE CONDITION LEVER (CLA) ON AUTO
POSITION.
3. ON PANEL 24VU,
ON AFR AIR BLEED PUSHBUTTON SWITCH (2):
- FAULT LEGEND ON,
- OFF LEGEND OFF.
4. FOLLOWING ALERTS APPEAR:
- ON CAP, ANTI ICING ANNUNCIATOR COMES ON,
- CAUTION ANNUNCIATORS COME ON,
- SINGLE CHIME SOUNDS.
5. ON PANEL 25VU, MAKE THE FOLLOWING
OPERATIONS:
- RELEASE (7UA1) MFC/1A PUSHBUTTON SWITCH
(8),
*** CONTINUED ***
AH

30-11-00
OPT 10000-006
2-400 PAGE
7
MAR 01/15

30-11-00

OPERATIONAL TEST OF
AIRFOIL DE-ICING SYSTEM

OPT 10000-006
8

MAR15

- WAIT FOR DE ICING CYCLE I.E. 60 SECONDS,


- PRESS (7UA1) MFC/1A PUSHBUTTON SWITCH
(8),
- WAIT FOR DE ICING CYCLE I.E. 60 SECONDS,
- RELEASE (7UA2) MFC/2A PUSHBUTTON SWITCH
(10),
- WAIT FOR DE ICING CYCLE I.E. 60 SECONDS,
- PRESS (7UA2) MFC/2A PUSHBUTTON SWITCH
(10).
6. DURING ABOVE OPERATIONS, ALERTS REMAIN ON.
7. ON PANEL 24VU,
A. RELEASE AFR AIR BLEED PUSHBUTTON
SWITCH (2):
- FAULT LEGEND OFF,
- OFF LEGEND ON.
B. ON AIR FRAME PUSHBUTTON SWITCH:
- FAULT LEGEND ON,
- ON LEGEND ON.
8. ALERTS REMAIN ON.
9. ON PANEL 25VU, MAKE THE FOLLOWING
OPERATIONS :
- RELEASE (7UA1) MFC/1A PUSHBUTTON SWITCH
(8),
- WAIT FOR DE ICING CYCLE I.E. 60 SECONDS,
- PRESS (7UA1) MFC/1A PUSHBUTTON SWITCH
(8),
- WAIT FOR DE ICING CYCLE I.E. 60 SECONDS,
- RELEASE (7UA2) MFC/2A PUSHBUTTON SWITCH
(10),
- WAIT FOR DE ICING CYCLE I.E. 60 SECONDS,
- PRESS (7UA2) MFC/2A PUSHBUTTON SWITCH
(10).
10.DURING ABOVE OPERATIONS, ALERTS REMAIN ON.
11.ON PANEL 24VU,
*** CONTINUED ***
AH

30-11-00
OPT 10000-006
2-400 PAGE
8
MAR 01/15

30-11-00

OPERATIONAL TEST OF
AIRFOIL DE-ICING SYSTEM

OPT 10000-006
9

MAR15

A. PRESS AFR AIR BLEED PUSHBUTTON


SWITCH (2):
- FAULT LEGEND ON,
- OFF LEGEND OFF.
B. RESET AIR FRAME PUSHBUTTON SWITCH (3):
- FAULT LEGEND OFF,
- ON LEGEND ON.
12.APPLY AIR PRESSURE TO SYSTEM OR RUN-UP
ENGINE.
13.ON PANEL 24VU,
ON AFR AIR BLEED PUSHBUTTON SWITCH (2):
- FAULT LEGEND OFF,
- OFF LEGEND OFF.
14.ALERTS DISAPPEAR.
15.ON PANEL 24VU,
A. RELEASE AFR AIR BLEED PUSHBUTTON
SWITCH (2):
- FAULT LEGEND OFF,
- OFF LEGEND ON,
- ON CAP, ANTI ICING ANNUNCIATOR COMES
ON,
- CAUTION ANNUNCIATORS COME ON,
- SINGLE CHIME SOUNDS.
NOTE : IT IS NECESSARY TO RESET THE CAP
WITHIN 5 SECONDS IN ORDER TO CONTROL
THE PRESENCE OF THE SECOND ALERT.
B. ON AIR FRAME PUSHBUTTON SWITCH (3):
- FAULT LEGEND ON,
- ON LEGEND ON.
16.FOLLOWING ALERTS APPEAR:
- ON CAP, ANTI ICING ANNUNCIATOR COMES ON,
- CAUTION ANNUNCIATORS COME ON,
- SINGLE CHIME SOUNDS.
*** CONTINUED ***
AH

30-11-00
OPT 10000-006
2-400 PAGE
9
MAR 01/15

30-11-00

OPERATIONAL TEST OF
AIRFOIL DE-ICING SYSTEM

OPT 10000-006
10

MAR15

17.ON PANEL 24VU,


A. RELEASE AIR FRAME PUSHBUTTON
SWITCH (3):
- FAULT LEGEND OFF,
- ON LEGEND OFF.
B. RELEASE MODE SEL/AUTO PUSHBUTTON
SWITCH (3):
- FAULT LEGEND OFF,
- MAN LEGEND OFF.
18.ALERTS DISAPPEAR.
18.ON PANEL 402VU, CHECK THAT DE-ICING
ANNUNCIATOR (4) IS OFF.
19.ON PANEL 702VU,
PLACE WEIGHT ON WHEELS SWITCH ON NORM.
20.PLACE THE CONDITION LEVER (CLA) ON FUEL SO
POSITION.
21.DISCONNECT GROUND AIR PRESSURIZATION UNIT
OR SHUT OFF ENGINE.
NOTE : A. REPEAT TEST WITH GROUND AIR PRESSURIZATION UNIT CONNECTED TO REGULATOR AND SHUT OFF VALVE
OF RIGHT ENGINE.
B. BY MEANS OF THE PROCEDURE BELLOW MAKE
SURE THAT THE FOLLOWING FAILURE ARE
NOT MEMORIZED IN MFC MAINTENANCE
MEMORY.
BOOTS MEMORY :
- LEFT WING BOOT A FAULT
- RIGHT WING BOOT A FAULT
- LEFT WING BOOT B FAULT
- RIGHT WING BOOT B FAULT
- LEFT MEDIAN WING BOOT A FAULT
- RIGHT MEDIAN WING BOOT A FAULT
*** CONTINUED ***
AH

30-11-00
OPT 10000-006
2-400 PAGE
10
MAR 01/15

30-11-00

OPERATIONAL TEST OF
AIRFOIL DE-ICING SYSTEM

OPT 10000-006
11

MAR15

- LEFT MEDIAN WING BOOT B FAULT


- RIGHT MEDIAN WING BOOT B FAULT
- LEFT EMPENAGE BOOT A FAULT
- LEFT EMPENAGE BOOT B FAULT
MISCELANEOUS 2 MEMORY :
- FIN OPTIONAL BOOTS A FAULT
- FIN OPTIONAL BOOTS B FAULT
MISCELANEOUS 4 MEMORY :
- RIGHT EMPENAGE BOOT A FAULT
- RIGHT EMPENAGE BOOT B FAULT
010

_________________________________
READING
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RDG-10000

011

_________________________________
ERASURE
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RON-10000

012

______________________________________________
DE-ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000

013

________
CLOSE-UP
1. MAKE CERTAIN THAT WORKING AREA IS CLEAN AND
CLEAR OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
2. CLOSE ACCESS DOOR PREVIOUSLY OPENED.
3. INSTALL ITEMS PREVIOUSLY REMOVED.
4. CLOSE ENGINES COWLS 435AL AND 445AL.
5. REMOVE ACCESS PLATFORMS AND STEP LADDER.

*** CONTINUED ***


AH

30-11-00
OPT 10000-006
2-400 PAGE
11
MAR 01/15

30-11-00

OPERATIONAL TEST OF
AIRFOIL DE-ICING SYSTEM

014

OPT 10000-006
12

MAR15

_____________________________
INSTALLATION
OF LEADING EDGES
SEE JOB INSTRUCTION CARD
574000-RAI-10000

015

___________________________________
CLOSING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000
*****

AH

E N D

O F

T E X T

*****

30-11-00
OPT 10000-006
2-400 PAGE
12
MAR 01/15

30-11-00
13

AH

CONTROLS AND INDICATING


WING/ENGINE DE ICING

OPT 10000-006
MAR15

30-11-00
OPT 10000-006

2-400

PAGE
13
MAR 01/15

30-11-00
14

AH

TEST COUPLING - PRESSURE


REGULATOR AND SHUT-OFF
VALVE

OPT 10000-006
MAR15

30-11-00
OPT 10000-006

2-400

PAGE
14
MAR 01/15

30-11-00

OPERATIONAL TEST OF
AIRFOIL DE-ICING SYSTEM

OPT 10000-007
1

MAR15

ZONING DATA
___________
ZONE

ACCESS

: 310
435
510
610
: 435AL
512
612
851

445
445AL
514
614

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

GSE

: 06 ACCESS PLATFORM
01 STEP LADDER
01 AIR PRESS UNIT 4 B(58 PSI)

_________
MAN-HOURS

PUBLICATION
___________
JIC
JIC
JIC
JIC
JIC

: REMOVAL/INSTALLATION OF
LEADING EDGES
: OPENING AND CLOSING OF
HINGED ENGINE COWLS
: DC AND AC EXTERNAL POWER
SUPPLY
: READING OF MFC
MAINTENANCE MEMORY
: ERASURE OF MFC
MAINTENANCE MEMORY

AH

57-40-00-RAI-10000
54-00-00-OAC-10000
24-40-00-EAD-10000
45-13-00-RDG-10000
45-13-00-RON-10000

30-11-00
OPT 10000-007
2-400 PAGE
1
MAR 01/15

30-11-00

OPERATIONAL TEST OF
AIRFOIL DE-ICING SYSTEM

001

OPT 10000-007
2

MAR15

___________
PREPARATION
1. INSTALL PLATFORM SO AS TO HAVE ACCESS TO
FOLLOWING EQUIPMENTS :
A. ON ENGINE L AND R
. REGULATOR AND SHUT OFF VALVE 13DM AND
14DM.
B. ON WING L AND R
. DUAL DISTRIBUTOR VALVE 9DM, 10DM, 83DM
AND 84DM.
2. OPEN ACCESS DOOR 851 AND INSTALL STEP LADDER
SO AS TO HAVE ACCESS TO FOLLOWING EQUIPMENTS
A. TO HORIZONTAL STABILIZER DUAL DISTRIBUTOR
VALVE 11DM.
3. OPEN ENGINE PANELS 435AL (445AL).
4. REMOVE THE FOLLOWING LEADING EDGE TO ACCES
TO DUAL DISTRIBUTOR VALVES :
512 => VALVE 83DM
612 => VALVE 84DM
514 => VALVE 9DM
614 => VALVE 10DM
5. BY MEANS OF THE BELOW PROCEDURE CHECK IF
SYSTEM BOOTS FAILURE IS MEMORIZED IN
MFC MAINTENANCE MEMORY.

002

________________________
REMOVAL
OF LEADING EDGES
SEE JOB INSTRUCTION CARD
574000-RAI-10000

003

___________________________________
OPENING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000
*** CONTINUED ***
AH

30-11-00
OPT 10000-007
2-400 PAGE
2
MAR 01/15

30-11-00

OPERATIONAL TEST OF
AIRFOIL DE-ICING SYSTEM

004

OPT 10000-007
3

MAR15

___________________________________________
ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000

005

_________________________________
READING
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RDG-10000

006

_________________________________
ERASURE
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RON-10000
NOTE:THIS TASK MUST BE PERFORMED ONLY IF FAULTS
RELATIVE TO THE SYSTEM TO BE CHECKED HAVE
BEEN RECORDED BY THE MFC MAINTENANCE
MEMORY.

007

OPERATIONAL TEST OF AIRFOIL SURFACE ICE


_______________________________________
PROTECTION AND WARNINGS USING EACH
__________________________________
REGULATOR AND SHUTOFF VALVE
___________________________
REF. FIG. 301100-OPT-00100
REF. FIG. 301100-OPT-00110
TO PERFORM TEST, CONNECT GROUND AIR
PRESSURIZATION UNIT 4 BARS (58 PSI)
(60L/SEC) TO LEFT REGULATOR VALVE TEST
PORT 1.
NOTE: THIS TEST CAN BE PERFORMED ALSO WITH
ROTATING ENGINES.ENGINE COWLS CLOSED.
AFTER AN ENGINE REPLACEMENT,PERFORM
TEST DURING ENGINE ADJUSTMENT AT
RUN-UP.
1. PLACE AIRCRAFT IN FLIGHT CONFIGURATION.
ON PANEL 702VU:
PLACE SWITCH WEIGHT ON WHEELS IN FLT
*** CONTINUED ***
AH

30-11-00
OPT 10000-007
2-400 PAGE
3
MAR 01/15

30-11-00

OPERATIONAL TEST OF
AIRFOIL DE-ICING SYSTEM

OPT 10000-007
4

MAR15

POSITION.
2. ON PANEL 24VU,
A. CHECK THAT AIR FRAME AIR BLEED
PUSHBUTTON SWITCH (2) IS PRESSED:
- FAULT LEGEND OFF,
- OFF LEGEND OFF.
B. PRESS MODE SEL/AUTO PUSHBUTTON
SWITCH (5):
- FAULT LEGEND OFF,
- MAN LEGEND ON.
C. CHECK THAT MODE SEL/ PUSHBUTTON
SWITCH (1) IS RELEASED (OUT):
- SLOW LEGEND OFF.
3. PRESS AIRFRAME PUSHBUTTON SWITCH (3):
- FAULT LEGEND OFF,
- ON LEGEND ON.
4. ON PANEL 402VU,
CHECK THAT ANTI ICING ANNUNCIATOR
(4) IS ON.
5. WAIT FOR DE ICING CYCLE, I.E. 60 SECONDS.
NO ALERTS MUST APPEAR.
6. ON PANEL 24VU,
PRESS MODE SEL PUSHBUTTON SWITCH (1):
- SLOW LEGEND ON.
7. WAIT FOR DE ICING CYCLE I.E. 180 SECONDS.
NO ALERTS MUST APPEAR.
NOTE: PERFORM THIS TEST ONLY WHEN USING A
A COMPRESSOR GROUND UNIT
CHECK MANUALLY AND AURALLY FOR AIR
LEAKAGE OF REGULATOR AND SHUTOFF VALVES
(5) AND(6) AT LEVEL OF REGULATION BELLOWS
(10) LOCATED UNDER THE VALVES, AND FOR
*** CONTINUED ***
AH

30-11-00
OPT 10000-007
2-400 PAGE
4
MAR 01/15

30-11-00

OPERATIONAL TEST OF
AIRFOIL DE-ICING SYSTEM

OPT 10000-007
5

MAR15

AIR LEAKAGE OF DUAL DISTRIBUTOR VALVES,


(1),(2),(3),(8) AND (9)AND AIR JET PUMP
(11) LOCATED AT THE UPPER END OF THE
VALVES.
DURING THE DE ICERS BOOTS A AND B INFLATE
CHECK VISUALY ON THE ALL DE ICERS SURFACE
THE ABSENCE OF FLATULENCE OR UNGLUING.
8. ON PANEL 24VU,
RELEASE PUSHBUTTON SWITCH (1):
- SLOW LEGEND OFF.
9. ON PANEL 25VU
RELEASE (7UA1) MFC/1A AND (6UA2) MFC/2B
PUSHBUTTON SWITCHES (8) AND (11):
- FAULT LEGEND OFF,
- OFF LEGEND ON.
10.WAIT FOR DE ICING CYCLE, I.E. 60 SECONDS.
NO ALERTS MUST APPEAR.
11.ON PANEL 24VU,
PRESS MODE SEL PUSHBUTTON SWITCH (1):
- SLOW LEGEND ON.
12.WAIT FOR DE ICING CYCLE I.E. 180 SECONDS.
NO ALERTS MUST APPEAR.
13.ON PANEL 24VU,
RELEASE PUSHBUTTON SWITCH (1):
- SLOW LEGEND OFF.
14.ON PANEL 25VU,
PRESS (7UA1) MFC/1A AND (6UA2) MFC/2B
PUSHBUTTON SWITCHES (8) AND (11):
- FAULT LEGEND OFF,
- OFF LEGEND OFF.
15.ON PANEL 25VU,
RELEASE (6UA1) MFC/1B AND (7UA2) MFC/2A
PUSHBUTTON SWITCHES (8) AND (10):
*** CONTINUED ***
AH

30-11-00
OPT 10000-007
2-400 PAGE
5
MAR 01/15

30-11-00

OPERATIONAL TEST OF
AIRFOIL DE-ICING SYSTEM

OPT 10000-007
6

MAR15

- FAULT LEGEND OFF,


- OFF LEGEND ON.
16.WAIT FOR DE ICING CYCLE I.E. 60 SECONDS.
NO ALERTS MUST APPEAR.
17.ON PANEL 24VU,
PRESS MOD SEL PUSHBUTTON SWITCH (1):
- SLOW LEGEND ON.
18.WAIT FOR DE ICING CYCLE I.E. 180 SECONDS.
NO ALERTS MUST APPEAR.
19.ON PANEL 24VU,
RELEASE PUSHBUTTON SWITCH (1):
- SLOW LEGEND OFF.
20.ON PANEL 25VU,
PRESS (6UA1) MFC/1B AND (7UA2) MFC/2A
PUSHBUTTON SWITCHES (9) AND (10):
- FAULT LEGEND OFF,
- OFF LEGEND OFF.
21.ON PANEL 702VU,
PLACE WEIGHT ON WHEELS SWITCH ON NORM.
22.DISCONNECT GROUND AIR PRESSURIZATION UNIT
OR SHUT OFF ENGINE.
NOTE: USING THE BELOW PROCEDURE MAKE SURE THAT
THE FOLLOWING FAILURE ARE NOT MEMORIZED IN THE
MFC MAINTENANCE MEMORY
BOOTS MEMORY
- LEFT WING BOOT A FAULT
- RIGHT WING BOOT A FAULT
- LEFT WING BOOT B FAULT
- RIGHT WING BOOT B FAULT
- LEFT MEDIAN WING BOOT A FAULT
- RIGHT MEDIAN WING BOOT A FAULT
- LEFT MEDIAN WING BOOT B FAULT
- RIGHT MEDIAN WING BOOT B FAULT
*** CONTINUED ***
AH

30-11-00
OPT 10000-007
2-400 PAGE
6
MAR 01/15

30-11-00

OPERATIONAL TEST OF
AIRFOIL DE-ICING SYSTEM

OPT 10000-007
7

MAR15

- LEFT EMPENAGE BOOT A FAULT


- LEFT EMPENAGE BOOT B FAULT
MISCELLANEOUS 2 MEMORY:
- FIN OPTIONAL BOOTS A FAULT
- FIN OPTIONAL BOOTS B FAULT
MISCELLANEOUS 4 MEMORY
- RIGHT EMPENAGE BOOT A FAULT
- RIGHT EMPENAGE BOOT B FAULT
NAVIGATION MEMORY
- LH PRSOV NORMAL PRESS FAULT
- RH PRSOV NORMAL PRESS FAULT
008

_________________________________
READING
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RDG-10000

009

OPERATIONAL TEST OF AIRFOIL SURFACE ICE


_______________________________________
PROTECTION AND WARNINGS USING EACH
__________________________________
REGULATOR AND SHUTOFF VALVE
___________________________
REF. FIG. 301100-OPT-00100
REF. FIG. 301100-OPT-00110
1. ON PANEL 702VU:
PLACE SWITCH WEIGHT ON WHEELS IN FLT
POSITION.
2. PLACE THE CONDITION LEVER (CLA) ON AUTO
POSITION.
3. ON PANEL 24VU,
ON AFR AIR BLEED PUSHBUTTON SWITCH (2):
- FAULT LEGEND ON,
- OFF LEGEND OFF.
4. FOLLOWING ALERTS APPEAR :
- ON CAP, ANTI ICING ANNUNCIATOR COMES ON,
- CAUTION ANNUNCIATORS COME ON,
- SINGLE CHIME SOUNDS.
*** CONTINUED ***
AH

30-11-00
OPT 10000-007
2-400 PAGE
7
MAR 01/15

OPERATIONAL TEST OF
AIRFOIL DE-ICING SYSTEM

30-11-00

OPT 10000-007
8

MAR15

5. ON PANEL 25VU, MAKE THE FOLLOWING


OPERATIONS:
- RELEASE (7UA1) MFC/1A PUSHBUTTON SWITCH
(8),
- WAIT FOR DE ICING CYCLE I.E. 60 SECONDS,
- PRESS (7UA1) MFC/1A PUSHBUTTON SWITCH
(8),
- WAIT FOR DE ICING CYCLE I.E. 60 SECONDS,
- RELEASE (7UA2) MFC/2A PUSHBUTTON SWITCH
(10),
- WAIT FOR DE ICING CYCLE I.E. 60 SECONDS,
- PRESS (7UA2) MFC/2A PUSHBUTTON SWITCH
(10),
6. DURING ABOVE OPERATIONS, ALERTS REMAIN ON.
7. ON PANEL 24VU,
A. RELEASE AFR AIR BLEED PUSHBUTTON
SWITCH (2):
- FAULT LEGEND OFF,
- OFF LEGEND ON.
B. ON AIR FRAME PUSHBUTTON SWITCH (3):
- FAULT LEGEND ON,
- ON LEGEND ON.
8. ALERTS REMAIN ON.
9. ON PANEL 25VU, MAKE THE FOLLOWING
OPERATIONS:
- RELEASE (7UA1) MFC/1A PUSHBUTTON SWITCH
(8),
- WAIT FOR DE ICING CYCLE I.E. 60 SECONDS,
- PRESS (7UA1) MFC/1A PUSHBUTTON SWITCH
(8),
- WAIT FOR DE ICING CYCLE I.E. 60 SECONDS,
- RELEASE (7UA2) MFC/2A PUSHBUTTON SWITCH
(10),
- WAIT FOR DE ICING CYCLE I.E. 60 SECONDS,
- PRESS (7UA2) MFC/2A PUSHBUTTON SWITCH
(10).
*** CONTINUED ***
AH

30-11-00
OPT 10000-007
2-400 PAGE
8
MAR 01/15

30-11-00

OPERATIONAL TEST OF
AIRFOIL DE-ICING SYSTEM

OPT 10000-007
9

MAR15

10.DURING ABOVE OPERATIONS, ALERTS REMAIN ON.


11.ON PANEL 24VU,
A. PRESS AFR AIR BLEED PUSHBUTTON
SWITCH (2):
- FAULT LEGEND ON,
- OFF LEGEND OFF.
B. RESET AIR FRAME PUSHBUTTON SWITCH (3):
- FAULT LEGEND OFF,
- ON LEGEND ON.
12.APPLY AIR PRESSURE TO SYSTEM OR RUN-UP
ENGINE.
13.ON PANEL 24VU,
ON AFR AIR BLEED PUSHBUTTON SWITCH (2):
- FAULT LEGEND OFF,
- OFF LEGEND OFF.
14.ALERTS DISAPPEAR.
15.ON PANEL 24VU,
A. RELEASE AFR AIR BLEED PUSHBUTTON
SWITCH (2):
- FAULT LEGEND OFF,
- OFF LEGEND ON,
- ON CAP, ANTI ICING ANNUNCIATOR COMES
ON,
- CAUTION ANNUNCIATORS COME ON,
- SINGLE CHIME SOUNDS.
NOTE : IT IS NECESSARY TO RESET THE CAP
WITHIN 5 SECONDS IN ORDER TO CONTROL
THE PRESENCE OF THE SECOND ALERT.
B. ON AIR FRAME PUSHBUTTON SWITCH (3):
- FAULT LEGEND ON,
- ON LEGEND ON.
*** CONTINUED ***
AH

30-11-00
OPT 10000-007
2-400 PAGE
9
MAR 01/15

30-11-00

OPERATIONAL TEST OF
AIRFOIL DE-ICING SYSTEM

OPT 10000-007
10

MAR15

16.FOLLOWING ALERTS APPEAR:


- ON CAP, ANTI ICING ANNUNCIATOR COMES ON,
- CAUTION ANNUNCIATORS COME ON,
- SINGLE CHIME SOUNDS.
17.ON PANEL 24VU,
A. RELEASE AIR FRAME PUSHBUTTON
SWITCH (3):
- FAULT LEGEND OFF,
- ON LEGEND OFF.
B. RELEASE MODE SEL/AUTO PUSHBUTTON
SWITCH (3):
- FAULT LEGEND OFF,
- MAN LEGEND OFF.
18.ALERTS DISAPPEAR.
19.ON PANEL 402VU, CHECK THAT DE-ICING
ANNUNCIATOR (4) IS OFF.
20.ON PANEL 702VU,
PLACE WEIGHT ON WHEELS SWITCH ON NORM.
21.PLACE THE CONDITION LEVER (CLA) ON FUEL SO
POSITION.
22.DISCONNECT GROUND AIR PRESSURIZATION UNIT
OR SHUT OFF ENGINE.
NOTE : A. REPEAT TEST WITH GROUND AIR PRESSURIZATION UNIT CONNECTED TO REGULATOR AND SHUT OFF VALVE
OF RIGHT ENGINE.
B. USING THE BELOW PROCEDURE MAKE SURE
THAT THE FOLLOWING FAILURE ARE NOT
MEMORIZED IN MFC MAINTENANCE
MEMORY.
BOOTS MEMORY :
- LEFT WING BOOT A FAULT
*** CONTINUED ***
AH

30-11-00
OPT 10000-007
2-400 PAGE
10
MAR 01/15

30-11-00

OPERATIONAL TEST OF
AIRFOIL DE-ICING SYSTEM

OPT 10000-007
11

MAR15

RIGHT WING BOOT A FAULT


LEFT WING BOOT B FAULT
RIGHT WING BOOT B FAULT
LEFT MEDIAN WING BOOT A FAULT
RIGHT MEDIAN WING BOOT A FAULT
LEFT MEDIAN WING BOOT B FAULT
- RIGHT MEDIAN WING BOOT B FAULT
- LEFT EMPENAGE BOOT A FAULT
- LEFT EMPENAGE BOOT B FAULT
MISCELANEOUS 2 MEMORY :
- FIN OPTIONAL BOOTS A FAULT
- FIN OPTIONAL BOOTS B FAULT
MISCELANEOUS 4 MEMORY :
- RIGHT EMPENAGE BOOT A FAULT
- RIGHT EMPENAGE BOOT B FAULT
NAVIGATION MEMORY
- LH PRSOV NORMAL PRESS FAULT
- RH PRSOV NORMAL PRESS FAULT
010

_________________________________
READING
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RDG-10000

011

_________________________________
ERASURE
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RON-10000

012

______________________________________________
DE-ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000

013

________
CLOSE-UP
1. MAKE CERTAIN THAT WORKING AREA IS CLEAN AND
CLEAR OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
2. CLOSE ACCESS DOOR PREVIOUSLY OPENED.
*** CONTINUED ***
AH

30-11-00
OPT 10000-007
2-400 PAGE
11
MAR 01/15

30-11-00

OPERATIONAL TEST OF
AIRFOIL DE-ICING SYSTEM

OPT 10000-007
12

MAR15

3. INSTALL ITEMS PREVIOUSLY REMOVED.


4. CLOSE ENGINES COWLS 435AL AND 445AL.
5. REMOVE ACCESS PLATFORMS AND STEP LADDER.
014

_____________________________
INSTALLATION
OF LEADING EDGES
SEE JOB INSTRUCTION CARD
574000-RAI-10000

015

___________________________________
CLOSING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000
*****

AH

E N D

O F

T E X T

*****

30-11-00
OPT 10000-007
2-400 PAGE
12
MAR 01/15

30-11-00
13

AH

CONTROLS AND INDICATING


WING/ENGINE DE ICING

OPT 10000-007
MAR15

30-11-00
OPT 10000-007

2-400

PAGE
13
MAR 01/15

30-11-00
14

AH

TEST COUPLING - PRESSURE


REGULATOR AND SHUT-OFF
VALVE

OPT 10000-007
MAR15

30-11-00
OPT 10000-007

2-400

PAGE
14
MAR 01/15

30-11-00

OPERATIONAL TEST OF
AIRFOIL DE-ICING SYSTEM

OPT 10000-008
1

MAR15

ZONING DATA
___________
ZONE

ACCESS

: 310
435
510
610
: 435AL
512
612
851

445
445AL
514
614

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

GSE

: 06 ACCESS PLATFORM
01 STEP LADDER
01 AIR PRESS UNIT 4 B(58 PSI)

_________
MAN-HOURS

PUBLICATION
___________
JIC
JIC
JIC
JIC
JIC

: PRINCIPLE OF CDS USE


(DISPLAY UNITS
EXPLORATION)
: REMOVAL/INSTALLATION OF
LEADING EDGES
: OPENING AND CLOSING OF
HINGED ENGINE COWLS
: DC AND AC EXTERNAL POWER
SUPPLY
: READING OF MFC
MAINTENANCE MEMORY

AH

31-63-00-PRO-10000
57-40-00-RAI-10000
54-00-00-OAC-10000
24-40-00-EAD-10000
45-13-00-RDG-10000

30-11-00
OPT 10000-008
2-400 PAGE
1
MAR 01/15

OPERATIONAL TEST OF
AIRFOIL DE-ICING SYSTEM

30-11-00

OPT 10000-008
2

MAR15

PUBLICATION
___________
JIC

: ERASURE OF MFC
MAINTENANCE MEMORY

AH

45-13-00-RON-10000

30-11-00
OPT 10000-008
2-400 PAGE
2
MAR 01/15

30-11-00

OPERATIONAL TEST OF
AIRFOIL DE-ICING SYSTEM

001

OPT 10000-008
3

MAR15

PRINCIPLE OF CDS USE (DISPLAY UNITS


___________________________________
EXPLORATION)
____________
(TO USE ONLY IF NEEDED)
_______________________
SEE JOB INSTRUCTION CARD
316300-PRO-10000
NOTE: PROCEDURE TO USE ONLY IF NEEDED.
THIS PROCEDURE DESCRIBES LOCATION AND
MANAGEMENT OF THE DIFFERENT DISPLAY
WINDOWS PROVIDED BY THE THREE FORMATS
(PFD, EWD, MFD) PROPOSED ON THE FIVE
DISPLAY UNITS (DU).

002

___________
PREPARATION
1. INSTALL PLATFORM SO AS TO HAVE ACCESS TO
FOLLOWING EQUIPMENTS :
A. ON ENGINE L AND R
. REGULATOR AND SHUT OFF VALVE 13DM AND
14DM.
B. ON WING L AND R
. DUAL DISTRIBUTOR VALVE 9DM, 10DM, 83DM
AND 84DM.
2. OPEN ACCESS DOOR 851 AND INSTALL STEP LADDER
SO AS TO HAVE ACCESS TO FOLLOWING EQUIPMENTS
A. TO HORIZONTAL STABILIZER DUAL DISTRIBUTOR
VALVE 11DM.
3. OPEN ENGINE PANELS 435AL (445AL).
4. REMOVE THE FOLLOWING LEADING EDGE TO ACCES
TO DUAL DISTRIBUTOR VALVES :
512 => VALVE 83DM
612 => VALVE 84DM
514 => VALVE 9DM
614 => VALVE 10DM
*** CONTINUED ***
AH

30-11-00
OPT 10000-008
2-400 PAGE
3
MAR 01/15

30-11-00

OPERATIONAL TEST OF
AIRFOIL DE-ICING SYSTEM

OPT 10000-008
4

MAR15

5. BY MEANS OF THE BELOW PROCEDURE CHECK IF


SYSTEM BOOTS FAILURE IS MEMORIZED IN
MFC MAINTENANCE MEMORY.
003

________________________
REMOVAL
OF LEADING EDGES
SEE JOB INSTRUCTION CARD
574000-RAI-10000

004

___________________________________
OPENING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000

005

___________________________________________
ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000

006

_________________________________
READING
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RDG-10000

007

_________________________________
ERASURE
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RON-10000
NOTE:THIS TASK MUST BE PERFORMED ONLY IF FAULTS
RELATIVE TO THE SYSTEM TO BE CHECKED HAVE
BEEN RECORDED BY THE MFC MAINTENANCE
MEMORY.

008

OPERATIONAL TEST OF AIRFOIL SURFACE ICE


_______________________________________
PROTECTION AND WARNINGS USING EACH
__________________________________
REGULATOR AND SHUTOFF VALVE
___________________________
REF. FIG. 301100-OPT-00100
REF. FIG. 301100-OPT-00110
*** CONTINUED ***
AH

30-11-00
OPT 10000-008
2-400 PAGE
4
MAR 01/15

30-11-00

OPERATIONAL TEST OF
AIRFOIL DE-ICING SYSTEM

OPT 10000-008
5

MAR15

TO PERFORM TEST, CONNECT GROUND AIR


PRESSURIZATION UNIT 4 BARS (58 PSI)
(60L/SEC) TO LEFT REGULATOR VALVE TEST
PORT 1.
NOTE: THIS TEST CAN BE PERFORMED ALSO WITH
ROTATING ENGINES.ENGINE COWLS CLOSED.
AFTER AN ENGINE REPLACEMENT,PERFORM
TEST DURING ENGINE ADJUSTMENT AT
RUN-UP.
1. PLACE AIRCRAFT IN FLIGHT CONFIGURATION.
ON PANEL 702VU:
PLACE SWITCH WEIGHT ON WHEELS IN FLT
POSITION.
2. ON PANEL 24VU,
A. CHECK THAT AIR FRAME AIR BLEED
PUSHBUTTON SWITCH (2) IS PRESSED:
- FAULT LEGEND OFF,
- OFF LEGEND OFF.
B. PRESS MODE SEL/AUTO PUSHBUTTON
SWITCH (5):
- FAULT LEGEND OFF,
- MAN LEGEND ON,
- ON EWD, IN ALERT WINDOW, A-ICING AUTO
MESSAGE APPEARS.
C. CHECK THAT MODE SEL/ PUSHBUTTON
SWITCH (1) IS RELEASED (OUT):
- SLOW LEGEND OFF.
3. PRESS AIRFRAME PUSHBUTTON SWITCH (3):
- FAULT LEGEND OFF,
- ON LEGEND ON.
4. ON MFD, IN TEMPORARY SELECTION WINDOW,
CYAN AIRFRAME MESSAGE IS DISPLAYED.
5. WAIT FOR DE ICING CYCLE, I.E. 60 SECONDS.
*** CONTINUED ***
AH

30-11-00
OPT 10000-008
2-400 PAGE
5
MAR 01/15

30-11-00

OPERATIONAL TEST OF
AIRFOIL DE-ICING SYSTEM

OPT 10000-008
6

MAR15

NO ALERTS MUST APPEAR.


6. ON PANEL 24VU,
PRESS MODE SEL PUSHBUTTON SWITCH (1):
- SLOW LEGEND ON.
7. WAIT FOR DE ICING CYCLE I.E. 180 SECONDS.
NO ALERTS MUST APPEAR.
NOTE: PERFORM THIS TEST ONLY WHEN USING A
A COMPRESSOR GROUND UNIT
CHECK MANUALLY AND AURALLY FOR AIR
LEAKAGE OF REGULATOR AND SHUTOFF VALVES
(5) AND(6) AT LEVEL OF REGULATION BELLOWS
(10) LOCATED UNDER THE VALVES, AND FOR
AIR LEAKAGE OF DUAL DISTRIBUTOR VALVES,
(1),(2),(3),(8) AND (9)AND AIR JET PUMP
(11) LOCATED AT THE UPPER END OF THE
VALVES.
DURING THE DE ICERS BOOTS A AND B INFLATE
CHECK VISUALY ON THE ALL DE ICERS SURFACE
THE ABSENCE OF FLATULENCE OR UNGLUING.
8. ON PANEL 24VU,
RELEASE PUSHBUTTON SWITCH (1):
- SLOW LEGEND OFF.
9. ON PANEL 25VU
RELEASE (7UA1) MFC/1A AND (6UA2) MFC/2B
PUSHBUTTON SWITCHES (8) AND (11):
- FAULT LEGEND OFF,
- OFF LEGEND ON.
10.WAIT FOR DE ICING CYCLE, I.E. 60 SECONDS.
NO ALERTS MUST APPEAR.
11.ON PANEL 24VU,
PRESS MODE SEL PUSHBUTTON SWITCH (1):
- SLOW LEGEND ON.
12.WAIT FOR DE ICING CYCLE I.E. 180 SECONDS.
*** CONTINUED ***
AH

30-11-00
OPT 10000-008
2-400 PAGE
6
MAR 01/15

30-11-00

OPERATIONAL TEST OF
AIRFOIL DE-ICING SYSTEM

OPT 10000-008
7

MAR15

NO ALERTS MUST APPEAR.


13.ON PANEL 24VU,
RELEASE PUSHBUTTON SWITCH (1):
- SLOW LEGEND OFF.
14.ON PANEL 25VU,
PRESS (7UA1) MFC/1A AND (6UA2) MFC/2B
PUSHBUTTON SWITCHES (8) AND (11):
- FAULT LEGEND OFF,
- OFF LEGEND OFF.
15.ON PANEL 25VU,
RELEASE (6UA1) MFC/1B AND (7UA2) MFC/2A
PUSHBUTTON SWITCHES (8) AND (10):
- FAULT LEGEND OFF,
- OFF LEGEND ON.
16.WAIT FOR DE ICING CYCLE I.E. 60 SECONDS.
NO ALERTS MUST APPEAR.
17.ON PANEL 24VU,
PRESS MOD SEL PUSHBUTTON SWITCH (1):
- SLOW LEGEND ON.
18.WAIT FOR DE ICING CYCLE I.E. 180 SECONDS.
NO ALERTS MUST APPEAR.
19.ON PANEL 24VU,
RELEASE PUSHBUTTON SWITCH (1):
- SLOW LEGEND OFF.
20.ON PANEL 25VU,
PRESS (6UA1) MFC/1B AND (7UA2) MFC/2A
PUSHBUTTON SWITCHES (9) AND (10):
- FAULT LEGEND OFF,
- OFF LEGEND OFF.
21.ON PANEL 702VU,
PLACE WEIGHT ON WHEELS SWITCH ON NORM.
*** CONTINUED ***
AH

30-11-00
OPT 10000-008
2-400 PAGE
7
MAR 01/15

30-11-00

OPERATIONAL TEST OF
AIRFOIL DE-ICING SYSTEM

OPT 10000-008
8

MAR15

22.DISCONNECT GROUND AIR PRESSURIZATION UNIT


OR SHUT OFF ENGINE.
NOTE: USING THE BELOW PROCEDURE MAKE SURE THAT
THE FOLLOWING FAILURE ARE NOT MEMORIZED IN THE
MFC MAINTENANCE MEMORY
BOOTS MEMORY
- LEFT WING BOOT A FAULT
- RIGHT WING BOOT A FAULT
- LEFT WING BOOT B FAULT
- RIGHT WING BOOT B FAULT
- LEFT MEDIAN WING BOOT A FAULT
- RIGHT MEDIAN WING BOOT A FAULT
- LEFT MEDIAN WING BOOT B FAULT
- RIGHT MEDIAN WING BOOT B FAULT
- LEFT EMPENAGE BOOT A FAULT
- LEFT EMPENAGE BOOT B FAULT
MISCELLANEOUS 2 MEMORY:
- FIN OPTIONAL BOOTS A FAULT
- FIN OPTIONAL BOOTS B FAULT
MISCELLANEOUS 4 MEMORY
- RIGHT EMPENAGE BOOT A FAULT
- RIGHT EMPENAGE BOOT B FAULT
NAVIGATION MEMORY
- LH PRSOV NORMAL PRESS FAULT
- RH PRSOV NORMAL PRESS FAULT
009

_________________________________
READING
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RDG-10000

010

OPERATIONAL TEST OF AIRFOIL SURFACE ICE


_______________________________________
PROTECTION AND WARNINGS USING EACH
__________________________________
REGULATOR AND SHUTOFF VALVE
___________________________
REF. FIG. 301100-OPT-00100
REF. FIG. 301100-OPT-00110
1. ON PANEL 702VU:
PLACE SWITCH WEIGHT ON WHEELS IN FLT
*** CONTINUED ***
AH

30-11-00
OPT 10000-008
2-400 PAGE
8
MAR 01/15

OPERATIONAL TEST OF
AIRFOIL DE-ICING SYSTEM

30-11-00

OPT 10000-008
9

MAR15

POSITION.
2. PLACE THE CONDITION LEVER (CLA) ON AUTO
POSITION.
3. ON PANEL 24VU,
ON AFR AIR BLEED PUSHBUTTON SWITCH (2):
- FAULT LEGEND ON,
- OFF LEGEND OFF.
4. FOLLOWING ALERTS APPEAR:
- ON EWD, IN ALERT WINDOW, A-ICING BLEED
MESSAGE IS DISPLAYED,
- MASTER CAUTION ANNUNCIATORS COME ON,
- SINGLE CHIME SOUNDS.
5. ON PANEL 25VU, MAKE THE FOLLOWING
OPERATIONS:
- RELEASE (7UA1) MFC/1A PUSHBUTTON SWITCH
(8),
- WAIT FOR DE ICING CYCLE I.E. 60 SECONDS,
- PRESS (7UA1) MFC/1A PUSHBUTTON SWITCH
(8),
- WAIT FOR DE ICING CYCLE I.E. 60 SECONDS,
- RELEASE (7UA2) MFC/2A PUSHBUTTON SWITCH
(10),
- WAIT FOR DE ICING CYCLE I.E. 60 SECONDS,
- PRESS (7UA2) MFC/2A PUSHBUTTON SWITCH
(10).
6. DURING ABOVE OPERATIONS, ALERTS REMAIN ON.
7. ON PANEL 24VU,
A. RELEASE AFR AIR BLEED PUSHBUTTON
SWITCH (2):
- FAULT LEGEND OFF,
- OFF LEGEND ON.
B. ON AIR FRAME PUSHBUTTON SWITCH (3):
- FAULT LEGEND ON,
- ON LEGEND ON,
*** CONTINUED ***
AH

30-11-00
OPT 10000-008
2-400 PAGE
9
MAR 01/15

30-11-00

OPERATIONAL TEST OF
AIRFOIL DE-ICING SYSTEM

OPT 10000-008
10

MAR15

- ON MFD, IN TEMPORARY SELECTION WINDOW,


AMBER AIRFRAME MESSAGE IS DISPLAYED.
8. ALERTS REMAIN ON.
9. ON PANEL 25VU, MAKE THE FOLLOWING
OPERATIONS:
- RELEASE (7UA1) MFC/1A PUSHBUTTON SWITCH
(8),
- WAIT FOR DE ICING CYCLE I.E. 60 SECONDS,
- PRESS (7UA1) MFC/1A PUSHBUTTON SWITCH
(8),
- WAIT FOR DE ICING CYCLE I.E. 60 SECONDS,
- RELEASE (7UA2) MFC/2A PUSHBUTTON SWITCH
(10),
- WAIT FOR DE ICING CYCLE I.E. 60 SECONDS,
- PRESS (7UA2) MFC/2A PUSHBUTTON SWITCH
(10).
10.DURING ABOVE OPERATIONS, ALERTS REMAIN ON.
11.ON PANEL 24VU,
A. PRESS AFR AIR BLEED PUSHBUTTON
SWITCH (2):
- FAULT LEGEND ON,
- OFF LEGEND OFF.
B. RESET AIR FRAME PUSHBUTTON SWITCH (3):
- FAULT LEGEND OFF,
- ON LEGEND ON,
- ON MFD, IN TEMPORARY SELECTION WINDOW,
CYAN AIRFRAME MESSAGE IS DISPLAYED.
12.APPLY AIR PRESSURE TO SYSTEM OR RUN-UP
ENGINE.
13.ON PANEL 24VU,
ON AFR AIR BLEED PUSHBUTTON SWITCH (2):
- FAULT LEGEND OFF,
- OFF LEGEND OFF.
*** CONTINUED ***
AH

30-11-00
OPT 10000-008
2-400 PAGE
10
MAR 01/15

OPERATIONAL TEST OF
AIRFOIL DE-ICING SYSTEM

30-11-00

OPT 10000-008
11

MAR15

14.ALERTS DISAPPEAR.
15.ON PANEL 24VU,
A. RELEASE AFR AIR BLEED PUSHBUTTON
SWITCH (2):
- FAULT LEGEND OFF,
- OFF LEGEND ON,
- ON EWD, IN ALERT WINDOW, A-ICING
MESSAGE IS DISPLAYED,
- MASTER CAUTION ANNUNCIATORS COME ON,
- SINGLE CHIME SOUNDS.
B. ON AIR FRAME PUSHBUTTON SWITCH (3):
- FAULT LEGEND ON,
- ON LEGEND ON,
- ON MFD, IN TEMPORARY SELECTION WINDOW,
AMBER AIRFRAME MESSAGE IS DISPLAYED.
16.FOLLOWING ALERTS APPEAR:
- ON EWD, IN ALERT WINDOW, A-ICING FRAME
MESSAGE IS DISPLAYED,
- MASTER CAUTION ANNUNCIATORS COME ON,
- SINGLE CHIME SOUNDS.
17.ON PANEL 24VU,
A. RELEASE AIR FRAME PUSHBUTTON
SWITCH (3):
- FAULT LEGEND OFF,
- ON LEGEND OFF,
- ON MFD, IN TEMPORARY SELECTION WINDOW,
AIRFRAME MESSAGE DISAPPEARS.
B. RELEASE MODE SEL/AUTO PUSHBUTTON
SWITCH (3):
- FAULT LEGEND OFF,
- MAN LEGEND OFF.
18.ALERTS DISAPPEAR.
19.ON PANEL 702VU,
PLACE WEIGHT ON WHEELS SWITCH ON NORM.
*** CONTINUED ***
AH

30-11-00
OPT 10000-008
2-400 PAGE
11
MAR 01/15

30-11-00

OPERATIONAL TEST OF
AIRFOIL DE-ICING SYSTEM

OPT 10000-008
12

MAR15

20.PLACE THE CONDITION LEVER (CLA) ON FUEL SO


POSITION.
21.DISCONNECT GROUND AIR PRESSURIZATION UNIT
OR SHUT OFF ENGINE.
NOTE : A. REPEAT TEST WITH GROUND AIR PRESSURIZATION UNIT CONNECTED TO REGULATOR AND SHUT OFF VALVE
OF RIGHT ENGINE.
B. USING THE BELOW PROCEDURE MAKE SURE
THAT THE FOLLOWING FAILURE ARE NOT
MEMORIZED IN MFC MAINTENANCE
MEMORY.
BOOTS MEMORY :
- LEFT WING BOOT A FAULT
- RIGHT WING BOOT A FAULT
- LEFT WING BOOT B FAULT
- RIGHT WING BOOT B FAULT
- LEFT MEDIAN WING BOOT A FAULT
- RIGHT MEDIAN WING BOOT A FAULT
- LEFT MEDIAN WING BOOT B FAULT
- RIGHT MEDIAN WING BOOT B FAULT
- LEFT EMPENAGE BOOT A FAULT
- LEFT EMPENAGE BOOT B FAULT
MISCELANEOUS 2 MEMORY :
- FIN OPTIONAL BOOTS A FAULT
- FIN OPTIONAL BOOTS B FAULT
MISCELANEOUS 4 MEMORY :
- RIGHT EMPENAGE BOOT A FAULT
- RIGHT EMPENAGE BOOT B FAULT
NAVIGATION MEMORY
- LH PRSOV NORMAL PRESS FAULT
- RH PRSOV NORMAL PRESS FAULT
011

_________________________________
READING
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RDG-10000
*** CONTINUED ***
AH

30-11-00
OPT 10000-008
2-400 PAGE
12
MAR 01/15

30-11-00

OPERATIONAL TEST OF
AIRFOIL DE-ICING SYSTEM

012

OPT 10000-008
13

MAR15

_________________________________
ERASURE
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RON-10000

013

______________________________________________
DE-ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000

014

________
CLOSE-UP
1. MAKE CERTAIN THAT WORKING AREA IS CLEAN AND
CLEAR OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
2. CLOSE ACCESS DOOR PREVIOUSLY OPENED.
3. INSTALL ITEMS PREVIOUSLY REMOVED.
4. CLOSE ENGINES COWLS 435AL AND 445AL.
5. REMOVE ACCESS PLATFORMS AND STEP LADDER.

015

_____________________________
INSTALLATION
OF LEADING EDGES
SEE JOB INSTRUCTION CARD
574000-RAI-10000

016

___________________________________
CLOSING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000
*****

AH

E N D

O F

T E X T

*****

30-11-00
OPT 10000-008
2-400 PAGE
13
MAR 01/15

30-11-00
14

AH

CONTROLS AND INDICATING


WING/ENGINE DE ICING

OPT 10000-008
MAR15

30-11-00
OPT 10000-008

2-400

PAGE
14
MAR 01/15

30-11-00
15

AH

TEST COUPLING - PRESSURE


REGULATOR AND SHUT-OFF
VALVE

OPT 10000-008
MAR15

30-11-00
OPT 10000-008

2-400

PAGE
15
MAR 01/15

30-11-00

OPERATIONAL TEST OF
ANTI-ICING AND WARNING
OF EACH HORN

OPT 10030-001
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 210
: 214BZ

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

___
MEN

_________
MAN-HOURS

PUBLICATION
___________
JIC

: DC AND AC EXTERNAL POWER


SUPPLY

AH

24-40-00-EAD-10000

30-11-00
OPT 10030-001
2-400 PAGE
1
DEC 01/14

30-11-00

OPERATIONAL TEST OF
ANTI-ICING AND WARNING
OF EACH HORN

001

OPT 10030-001
2

DEC14

___________
PREPARATION
1. ON RACK 90VU, OPEN PANEL 214BZ.
2. CHECK THAT CONCERNED SYSTEM CIRCUIT BREAKERS
ARE CLOSED.

002

___________________________________________
ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000

003

OPERATIONAL TEST OF ANTI ICING AND ALERT OF


___________________________________________
EACH HORN
_________
REF. FIG. 301100-OPT-00140
REF. FIG. 301100-CHK-00100
WARNING: HORNS QUICKLY REACH A HIGH
TEMPERATURE IN ABOUT 10 SECONDS.
IT IS IMPORTANT NOT TO HEAT HORNS MORE
THAN 60 SECONDS AND DO NOT TOUCH THE
HORNS.
PLACE AIRCRAFT IN FLIGHT CONFIGURATION.
ON PANEL 702VU,
PLACE WEIGHT ON WHEELS SWITCH ON FLT
POSITION.
ON CENTER PEDESTAL,
PLACE CONDITION LEVER IN AUTO POSITION
1. ON PANEL 24VU,
PRESS HORNS/RUD & L ELEV PUSHBUTTON
SWITCH (1) :
- FAULT LEGEND OFF,
- ON LEGEND ON.
2. ON PANEL 4VU,
ICING AOA PUSHBUTTON SWITCH (4) IS ON.
3. ON PANEL 126VU,
*** CONTINUED ***
AH

30-11-00
OPT 10030-001
2-400 PAGE
2
DEC 01/14

30-11-00

OPERATIONAL TEST OF
ANTI-ICING AND WARNING
OF EACH HORN

OPT 10030-001
3

DEC14

OPEN THE FOLLOWING CIRCUIT BREAKER :


51DM HORNS/ ANTI-ICING PWR SPLY/RUD
4. ON PANEL 24VU,
ON HORNS/RUD & L ELEV PUSHBUTTON
SWITCH (1) :
- ON LEGEND ON,
- FAULT LEGEND ON.
5. THE FOLLOWING WARNINGS APPEAR :
- ON CAP, ANTI ICING ANNUNCIATOR COMES ON,
- CAUTION ANNUNCIATORS COME ON,
- SINGLE CHIME SOUNDS
6. ON FRONT FACE OF ANTI-ICING HORNS CONTROLLER
LOCATED ON SHELF 93VU, ELECTRICS RACKS 90VU:
- CANAL2 LIGHT COMES ON.
7. ON PANEL 126VU,
CLOSE CIRCUIT BREAKER PREVIOUSLY OPENED.
8. ON PANEL 24VU,
ON HORNS/RUD & L ELEV PUSHBUTTON
SWITCH (1) :
- FAULT LEGEND OFF,
- ON LEGEND ON.
9. WARNINGS DISAPPEAR.
10.ON FRONT FACE OF ANTI-ICING HORNS CONTROLLER
CANAL2 LIGHT IS ON.
- PRESS TEST PUSHBUTTON :
. CANAL2 LIGHT GOES OFF.
11.ON PANEL 126VU,
OPEN THE FOLLOWING CIRCUIT BREAKER :
63DM HORNS/ANTI-ICING PWR SPLY/L ELEV
12.ON PANEL 24VU,
ON HORNS/RUD & L ELEV PUSHBUTTON
SWITCH (1) :
*** CONTINUED ***
AH

30-11-00
OPT 10030-001
2-400 PAGE
3
DEC 01/14

30-11-00

OPERATIONAL TEST OF
ANTI-ICING AND WARNING
OF EACH HORN

OPT 10030-001
4

DEC14

- ON LEGEND ON,


- FAULT LEGEND ON.
13.THE FOLLOWING WARNINGS APPEAR :
- ON CAP ANTI-ICING ANNUNCIATOR COMES ON,
- CAUTION ANNUNCIATORS COME ON,
- SINGLE CHIME SOUNDS.
14.ON FRONT FACE OF ANTI-ICING HORNS CONTROLLER
- CANAL1 LIGHT COMES ON.
15.ON PANEL 126VU,
CLOSE CIRCUIT BREAKER PREVIOUSLY OPENED.
16.ON PANEL 24VU,
ON HORNS/RUD &/L ELEV PUSHBUTTON
SWITCH (1) :
- FAULT LEGEND OFF,
- ON LEGEND ON.
17.WARNINGS DISAPPEAR.
18.ON FRONT FACE OF ANTI-ICING HORNS CONTROLLER
CANAL1 LIGHT IS ON.
- PRESS TEST PUSHBUTTON :
. CANAL1 LIGHT GOES OFF.
19.ON PANEL 24VU,
RELEASE HORNS/RUD & L ELEV PUSHBUTTON
SWITH (1) :
- FAULT LEGEND OFF,
- ON LEGEND OFF.
20.ON PANEL 4VU,
THE ICING AOA PUSHBUTTON SWITCH (4)
REMAINS ON.
- PRESS THEN RELEASE PUSHBUTTON SWITCH (4)
ICING AOA LEGEND GOES OFF.
21.IF A LIGHT OF CONTROLLER REMAINS ON AFTER
PRESSING TEST PUSHBUTTON :
*** CONTINUED ***
AH

30-11-00
OPT 10030-001
2-400 PAGE
4
DEC 01/14

30-11-00

OPERATIONAL TEST OF
ANTI-ICING AND WARNING
OF EACH HORN

OPT 10030-001
5

DEC14

- INTERNAL FAULT OF CONTROLLER.


22.ON PANEL 702VU, PLACE WEIGHT ON WHEELS
SWITCH ON NORM POSITION.
NOTE : PERFORM SAME TESTS WITH HORNS/AIL &
R ELEV PUSHBUTTON SWITCH (2)
CONTROLLER AND SUCCESSIVELY OPENING
FOLLOWINGS CIRCUIT BREAKERS :
32DM HORNS ANTI ICING PWR SPLY/R ELEV
(CANAL1 LIGHT)
48DM HORNS ANTI ICING PWR SPLY/L AIL
(CANAL3 LIGHT)
50DM HORNS ANTI ICING PWR SPLY/R AIL
(CANAL2 LIGHT)
004

______________________________________________
DE-ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000
*****

AH

E N D

O F

T E X T

*****

30-11-00
OPT 10030-001
2-400 PAGE
5
DEC 01/14

30-11-00
6

AH

OPERATIONAL TEST OF
ANTI-ICING AND WARNING
OF EACH HORN

OPT 10030-001
DEC14

30-11-00
OPT 10030-001

2-400

PAGE
6
DEC 01/14

30-11-00
7

AH

CHECK OF ANTI ICE


HORN CONTROLLERS

OPT 10030-001
DEC14

30-11-00
OPT 10030-001

2-400

PAGE
7
DEC 01/14

30-11-00

OPERATIONAL TEST OF
ANTI-ICING AND WARNING
OF EACH HORN

OPT 10030-002
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 210
: 214BZ

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
MECHANIC

___
MEN

_________
MAN-HOURS
01

ELAPSED TIME

GSE

: 01 DC AND AC GROUND PWR UNIT

PUBLICATION
___________
JIC
JIC

: PRINCIPLE OF CDS USE


(DISPLAY UNITS
EXPLORATION)
: DC AND AC EXTERNAL POWER
SUPPLY

AH

31-63-00-PRO-10000
24-40-00-EAD-10000

30-11-00
OPT 10030-002
2-400 PAGE
1
DEC 01/14

30-11-00

OPERATIONAL TEST OF
ANTI-ICING AND WARNING
OF EACH HORN

001

OPT 10030-002
2

DEC14

PRINCIPLE OF CDS USE (DISPLAY UNITS


___________________________________
EXPLORATION)
____________
(TO USE ONLY IF NEEDED)
_______________________
SEE JOB INSTRUCTION CARD
316300-PRO-10000
NOTE: PROCEDURE TO USE ONLY IF NEEDED.
THIS PROCEDURE DESCRIBES LOCATION AND
MANAGEMENT OF THE DIFFERENT DISPLAY
WINDOWS PROVIDED BY THE THREE FORMATS
(PFD, EWD, MFD) PROPOSED ON THE FIVE
DISPLAY UNITS (DU).

002

___________
PREPARATION
1. ON RACK 90VU, OPEN PANEL 214BZ.
2. CHECK THAT CONCERNED SYSTEM CIRCUIT BREAKERS
ARE CLOSED.

003

___________________________________________
ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000

004

OPERATIONAL TEST OF ANTI ICING AND WARNING


__________________________________________
FOR EACH HORN
_____________
REF. FIG. 301100-OPT-00140
REF. FIG. 301100-CHK-00100
WARNING: HORNS QUICKLY REACH A HIGH
TEMPERATURE IN ABOUT 10 SECONDS.
IT IS IMPORTANT NOT TO HEAT HORNS MORE
THAN 60 SECONDS AND DO NOT TOUCH THE
HORNS.
PLACE AIRCRAFT IN FLIGHT CONFIGURATION.
ON PANEL 702VU,
PLACE WEIGHT ON WHEELS SWITCH ON FLT
*** CONTINUED ***
AH

30-11-00
OPT 10030-002
2-400 PAGE
2
DEC 01/14

30-11-00

OPERATIONAL TEST OF
ANTI-ICING AND WARNING
OF EACH HORN

OPT 10030-002
3

DEC14

POSITION.
ON CENTER PEDESTAL,
PLACE CONDITION LEVER IN AUTO POSITION,
1. A. ON PANEL 24VU,
PRESS HORNS/RUD & L ELEV PUSHBUTTON
SWITCH (1) :
- FAULT LEGEND OFF,:
- ON LEGEND ON.
B. ON MFD, IN TEMPORARY SELECTION WINDOW,
CYAN 1 HORN IS DISPLAYED.
2. A. ON PANEL 401VM,
ICE DET/ICING AOA PUSHBUTTON
SWITCH (3) IS ON.
B. ON PFD, IN FMA WINDOW, ICING AOA
MESSAGE IS DISPLAYED.
3. ON PANEL 126VU,
OPEN THE FOLLOWING CIRCUIT BREAKER :
51DM HORNS/ ANTI-ICING PWR SPLY/RUD
4. A. ON PANEL 24VU,
ON HORNS/RUD & L ELEV PUSHBUTTON
SWITCH (1) :
- ON LEGEND ON,
- FAULT LEGEND ON.
B. ON MFD, IN TEMPORARY SELECTION WINDOW,
AMBER 1 HORN MESSAGE IS DISPLAYED.
5. THE FOLLOWING WARNINGS APPEAR :
- ON EWD, IN ALERT WINDOW, A-ICING,
HORNS 1 MESSAGE IS DISPLAYED
- MASTER CAUTION ANNUNCIATORS COME ON,
- SINGLE CHIME SOUNDS
6. ON FRONT FACE OF ANTI-ICING HORNS CONTROLLER
LOCATED ON SHELF 93VU, ELECTRICS RACK 90VU:
- CANAL2 LIGHT COMES ON.
7. ON PANEL 126VU,
*** CONTINUED ***
AH

30-11-00
OPT 10030-002
2-400 PAGE
3
DEC 01/14

OPERATIONAL TEST OF
ANTI-ICING AND WARNING
OF EACH HORN

30-11-00

OPT 10030-002
4

DEC14

CLOSE CIRCUIT BREAKER PREVIOUSLY OPENED.


8. A. ON PANEL 24VU,OUNDS.
ON HORNS/RUD & L ELEV PUSHBUTTON
SWITCH (1) :
- FAULT LEGEND OFF,
- ON LEGEND ON.
B. ON MFD, IN TEMPORARY SELECTION WINDOW,
CYAN 1 HORN MESSAGE IS DISPLAYED.
9. WARNINGS DISAPPEAR.
10.ON FRONT FACE OF ANTI-ICING HORNS CONTROLLER
CANAL2 LIGHT IS ON.
- PRESS TEST PUSHBUTTON :
. CANAL2 LIGHT GOES OFF.
11.ON PANEL 126VU,
OPEN THE FOLLOWING CIRCUIT BREAKER :
63DM HORNS/ANTI-ICING PWR SPLY/L ELEV
12.A. ON PANEL 24VU,
ON HORNS/RUD & L ELEV PUSHBUTTON
SWITCH (1) :
- ON LEGEND ON,
- FAULT LEGEND ON.
B. ON MFD, IN TEMPORARY SELECTION WINDOW,
AMBER 1 HORN MESSAGE IS DISPLAYED.
13.THE FOLLOWING WARNINGS APPEAR :
- ON EWD, IN ALERT WINDOW, A-ICING HORNS 1
MESSAGE IS DISPLAYED.
- MASTER CAUTION ANNUNCIATORS COME ON,
- SINGLE CHIME SOUNDS.
14.ON FRONT FACE OF ANTI-ICING HORNS CONTROLLER
- CANAL1 LIGHT COMES ON.
15.ON PANEL 126VU,
CLOSE CIRCUIT BREAKER PREVIOUSLY OPENED.
*** CONTINUED ***
AH

30-11-00
OPT 10030-002
2-400 PAGE
4
DEC 01/14

30-11-00

OPERATIONAL TEST OF
ANTI-ICING AND WARNING
OF EACH HORN

OPT 10030-002
5

DEC14

16.A. ON PANEL 24VU,


ON HORNS/RUD &/L ELEV PUSHBUTTON
SWITCH (1) :
- FAULT LEGEND OFF,
- ON LEGEND ON.
B. ON MFD, IN TEMPORARY SELECTION WINDOW,
CYAN 1 HORN MESSAGE IS DISPLAYED.
17.WARNINGS DISAPPEAR.
18.ON FRONT FACE OF ANTI-ICING HORNS CONTROLLER
CANAL1 LIGHT IS ON.
- PRESS TEST PUSHBUTTON :
. CANAL1 LIGHT GOES OFF.
19.A. ON PANEL 24VU,
RELEASE HORNS/RUD & L ELEV PUSHBUTTON
SWITH (1) :
- FAULT LEGEND OFF,
- ON LEGEND OFF.
B. ON MFD, IN TEMPORARY SELECTION WINDOW,
1 HORN MESSAGE DISAPPEAR.
20.A. ON PANEL 401VM,
THE ICE DET/ICING AOA PUSHBUTTON SWITCH
(3) REMAINS ON.
- PRESS THEN RELEASE PUSHBUTTON SWITCH
(3) ICING AOA LEGEND GOES OFF.
B. ON PFD, IN FMA WINDOW, ICING AOA
MESSAGE DISAPPEARS.
21.IF A CONTROLLER LIGHT REMAINS ON AFTER
PRESSING TEST PUSHBUTTON :
- INTERNAL FAULT OF CONTROLLER.
22.ON PANEL 702VU, PLACE WEIGHT ON WHEELS
SWITCH ON NORM POSITION.
NOTE: PERFORM SAME TESTS WITH HORNS/AIL &
R ELEV PUSHBUTTON SWITCH (2)
CONTROLLER AND SUCCESSIVELY
*** CONTINUED ***
AH

30-11-00
OPT 10030-002
2-400 PAGE
5
DEC 01/14

30-11-00

OPERATIONAL TEST OF
ANTI-ICING AND WARNING
OF EACH HORN

OPT 10030-002
6

DEC14

OPEN THE FOLLOWING CIRCUIT BREAKERS:


32DM HORNS ANTI ICING PWR SPLY/R ELEV
(CANAL1 LIGHT)
48DM HORNS ANTI ICING PWR SPLY/L AIL
(CANAL3 LIGHT)
50DM HORNS ANTI ICING PWR SPLY/R AIL
(CANAL2 LIGHT)
ON MFD, IN TEMPORARY SELECTION
WINDOW, IT WILL BE HORN 2 MESSAGE
WHICH IS DISPLAYED.
ON EWD, IN ALERT WINDOW, IT WILL BE
A-ICING HORNS 2 MESSAGE WHICH IS
DISPLAYED.
005

______________________________________________
DE-ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000
*****

AH

E N D

O F

T E X T

*****

30-11-00
OPT 10030-002
2-400 PAGE
6
DEC 01/14

30-11-00
7

AH

OPERATIONAL TEST OF
ANTI-ICING AND WARNING
OF EACH HORN

OPT 10030-002
DEC14

30-11-00
OPT 10030-002

2-400

PAGE
7
DEC 01/14

30-11-00
8

AH

CHECK OF ANTI ICE


HORN CONTROLLERS

OPT 10030-002
DEC14

30-11-00
OPT 10030-002

2-400

PAGE
8
DEC 01/14

30-11-00

OPERATIONAL TEST OF
AIRFRAME DE-ICING

OPT 10060-001
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 210
435
: 435AL

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

GSE

: 01 ACCESS PLATFORM
01 COMPRESSOR

_________
MAN-HOURS

PUBLICATION
___________
JIC
JIC

: OPENING AND CLOSING OF


HINGED ENGINE COWLS
: DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY

AH

54-00-00-OAC-10000
24-46-00-EAD-10000

30-11-00
OPT 10060-001
2-400 PAGE
1
DEC 01/14

30-11-00

OPERATIONAL TEST OF
AIRFRAME DE-ICING

001

OPT 10060-001
2

DEC14

___________
PREPARATION
1. INSTALL PLATFORM TO GAIN ACCESS TO VALVE
SHUT OFF REGULATOR.
2. OPEN ENGINE COWL 435AL.
3. INSTALL PLATFORMS TO GAIN ACCESS TO VARIOUS
DE-ICERS.

002

___________________________________
OPENING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000

003

ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


___________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

004

______________________
CHECK
OF MFC OPERATION
1. ON PANEL 25VU, CHECK THAT THE FOLLOWING
PUSHBUTTON SWITCHES ARE PRESSED
(OFF LEGENDS ARE OFF):
6UA1
6UA2
7UA1
7UA2

005

MFC/1B/FAULT/OFF
MFC/2B/FAULT/OFF
MFC/1A/FAULT/OFF
MFC/2A/FAULT/OFF

_____________________________________
OPERATIONAL
TEST OF AIRFRAME DE-ICING
REF. FIG. 301100-OPT-00100
301100-OPT-00110
1. TO PERFORM TEST, CONNECT COMPRESSOR 4 BARS
(58 PSI) (60 L/SEC) TO LEFT ENGINE REGULATOR
AND SHUT-OFF VALVE TEST PLUG.
*** CONTINUED ***
AH

30-11-00
OPT 10060-001
2-400 PAGE
2
DEC 01/14

30-11-00

OPERATIONAL TEST OF
AIRFRAME DE-ICING

OPT 10060-001
3

DEC14

NOTE : THIS TEST CAN BE PERFORMED ALSO WITH


ROTATING ENGINE. ENGINE COWLS CLOSED.
AFTER AN ENGINE REPLACEMENT, PERFORM
TEST DURING ENGINE ADJUSTMENT AT
RUN-UP.
2. ON PANEL 702VU,
PLACE SWITCH WEIGHT ON WHEELS IN FLT
POSITION.
3. ON PANEL 24VU,
A. CHECK THAT (20DM) AFR AIR BLEED
PUSHBUTTON SWITCH (2) IS PRESSED :
-FAULT LEGEND OFF,
-OFF LEGEND OFF.
B. PRESS (7DM) AIRFRAME PUSHBUTTOM SWITCH
(3) :
-FAULT LEGEND OFF,
-ON LEGEND ON.
4. ON PANEL 402VU,
CHECK THAT (12DM) DE ICING ANNUNCIATOR (4)
IS ON.
5. WAIT 3MN, NO WARNINGS MUST APPEAR.
NOTE : PERFORM THIS TEST ONLY WHEN THIS TEST
IS PERFORMED WITH A COMPRESSOR.
CHECK MANUALLY AND AURALLY FOR AIR
LEAKAGE AT LEVEL OF ELEMENT REMOVED.
CHECK VISUALLY DE-ICER INFLATING.
6. ON PANEL 24VU,
REALEASE (7DM) AIRFRAME PUSHBUTTOM SWITCH
(3) :
-FAULT LEGEND OFF,
-ON LEGEND OFF.
7. ON PANEL 402VU,
CHECK THAT (12DM) DE ICING ANNUNCIATOR (4)
*** CONTINUED ***
AH

30-11-00
OPT 10060-001
2-400 PAGE
3
DEC 01/14

30-11-00

OPERATIONAL TEST OF
AIRFRAME DE-ICING

OPT 10060-001
4

DEC14

IS OFF.
8. ON PANEL 702VU,
PLACE SWITCH WEIGHT ON WHEELS IN NORM
POSITION.
9. DISCONNECT GROUND AIR PRESSURIZATION UNIT
OR SHUTT OFF ENGINE.
10.INSTALL PROTECTIVE PLUG ON REGULATOR
VALVE TEST PORT.
006

DE-ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


______________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

007

________
CLOSE-UP
1. CHECK THAT WORKING AREA IS CLEAN AND CLEAR
OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
2. REMOVE ACCESS PLATFORM AFTER CLOSING ENGINE
COWLS 435AL AS FOLLOWS :

008

___________________________________
CLOSING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000
*****

AH

E N D

O F

T E X T

*****

30-11-00
OPT 10060-001
2-400 PAGE
4
DEC 01/14

30-11-00
5

AH

CONTROLS AND INDICATING


WING/ENGINE DE ICING

OPT 10060-001
DEC14

30-11-00
OPT 10060-001

2-400

PAGE
5
DEC 01/14

30-11-00
6

AH

TEST COUPLING - PRESSURE


REGULATOR AND SHUT-OFF
VALVE

OPT 10060-001
DEC14

30-11-00
OPT 10060-001

2-400

PAGE
6
DEC 01/14

30-11-00

OPERATIONAL TEST OF
AIRFRAME DE-ICING

OPT 10060-002
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 210
435
: 435AL

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

GSE

: 01 ACCESS PLATFORM
01 COMPRESSOR

_________
MAN-HOURS

PUBLICATION
___________
JIC
JIC

: OPENING AND CLOSING OF


HINGED ENGINE COWLS
: DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY

AH

54-00-00-OAC-10000
24-46-00-EAD-10000

30-11-00
OPT 10060-002
2-400 PAGE
1
DEC 01/14

30-11-00

OPERATIONAL TEST OF
AIRFRAME DE-ICING

001

OPT 10060-002
2

DEC14

___________
PREPARATION
1. INSTALL PLATFORM TO GAIN ACCESS TO VALVE
SHUT OFF REGULATOR.
2. OPEN ENGINE COWL 435AL.
3. INSTALL PLATFORMS TO GAIN ACCESS TO VARIOUS
DE-ICERS.

002

___________________________________
OPENING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000

003

ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


___________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

004

______________________
CHECK
OF MFC OPERATION
1. ON PANEL 25VU, CHECK THAT THE FOLLOWING
PUSHBUTTON SWITCHES ARE PRESSED
(OFF LEGENDS ARE OFF):
6UA1
6UA2
7UA1
7UA2

005

MFC/1B/FAULT/OFF
MFC/2B/FAULT/OFF
MFC/1A/FAULT/OFF
MFC/2A/FAULT/OFF

_____________________________________
OPERATIONAL
TEST OF AIRFRAME DE-ICING
REF. FIG. 301100-OPT-00100
301100-OPT-00110
1. TO PERFORM TEST, CONNECT GROUND AIR PRESSURIZATION UNIT 4 BARS (58 PSI) (60 L/SEC)
TO LEFT REGULATOR VALVE TEST PORT 1.
*** CONTINUED ***
AH

30-11-00
OPT 10060-002
2-400 PAGE
2
DEC 01/14

30-11-00

OPERATIONAL TEST OF
AIRFRAME DE-ICING

OPT 10060-002
3

DEC14

NOTE : THIS TEST CAN BE PERFORMED ALSO WITH


ROTATING ENGINE. ENGINE COWLS CLOSED.
AFTER AN ENGINE REPLACEMENT, PERFORM
TEST DURING ENGINE ADJUSTMENT AT
RUN-UP.
2. ON PANEL 702VU,
PLACE SWITCH WEIGHT ON WHEELS IN FLT
POSITION.
3. ON PANEL 24VU,
A. CHECK THAT (20DM) AFR AIR BLEED
PUSHBUTTON SWITCH (2) IS PRESSED :
-FAULT LEGEND OFF,
-OFF LEGEND OFF.
B. PRESS (7DM) AIRFRAME PUSHBUTTOM SWITCH
(3) :
-FAULT LEGEND OFF,
-ON LEGEND ON.
4. ON PANEL 402VU,
CHECK THAT (12DM) DE ICING ANNUNCIATOR (4)
IS ON.
5. WAIT 3MN, NO WARNINGS MUST APPEAR.
NOTE : PERFORM THIS TEST ONLY WHEN THIS TEST
IS PERFORMED WITH A COMPRESSOR.
CHECK MANUALLY AND AURALLY FOR AIR
LEAKAGE AT LEVEL OF ELEMENT REMOVED.
CHECK VISUALLY DE-ICER INFLATING.
6. ON PANEL 24VU,
REALEASE (7DM) AIRFRAME PUSHBUTTOM SWITCH
(3) :
-FAULT LEGEND OFF,
-ON LEGEND OFF.
7. ON PANEL 402VU,
CHECK THAT (12DM) DE ICING ANNUNCIATOR (4)
*** CONTINUED ***
AH

30-11-00
OPT 10060-002
2-400 PAGE
3
DEC 01/14

30-11-00

OPERATIONAL TEST OF
AIRFRAME DE-ICING

OPT 10060-002
4

DEC14

IS OFF.
8. ON PANEL 702VU,
PLACE SWITCH WEIGHT ON WHEELS IN NORM
POSITION.
9. DISCONNECT GROUND AIR PRESSURIZATION UNIT
OR SHUTT OFF ENGINE.
10.INSTALL PROTECTIVE PLUG ON REGULATOR
VALVE TEST PORT.
006

DE-ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


______________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

007

________
CLOSE-UP
1. CHECK THAT WORKING AREA IS CLEAN AND CLEAR
OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
2. REMOVE ACCESS PLATFORM AFTER CLOSING ENGINE
COWLS 435AL AS FOLLOWS :

008

___________________________________
CLOSING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000
*****

AH

E N D

O F

T E X T

*****

30-11-00
OPT 10060-002
2-400 PAGE
4
DEC 01/14

30-11-00
5

AH

CONTROLS AND INDICATING


WING/ENGINE DE ICING

OPT 10060-002
DEC14

30-11-00
OPT 10060-002

2-400

PAGE
5
DEC 01/14

30-11-00
6

AH

TEST COUPLING - PRESSURE


REGULATOR AND SHUT-OFF
VALVE

OPT 10060-002
DEC14

30-11-00
OPT 10060-002

2-400

PAGE
6
DEC 01/14

30-11-00

OPERATIONAL TEST OF
AIRFRAME DE-ICING

OPT 10060-003
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 210
435
: 435AL

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

GSE

: 01 ACCESS PLATFORM
01 COMPRESSOR

_________
MAN-HOURS

PUBLICATION
___________
JIC
JIC

: OPENING AND CLOSING OF


HINGED ENGINE COWLS
: DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY

AH

54-00-00-OAC-10000
24-46-00-EAD-10000

30-11-00
OPT 10060-003
2-400 PAGE
1
DEC 01/14

30-11-00

OPERATIONAL TEST OF
AIRFRAME DE-ICING

001

OPT 10060-003
2

DEC14

___________
PREPARATION
1. INSTALL PLATFORM TO GAIN ACCESS TO VALVE
SHUT OFF REGULATOR.
2. OPEN ENGINE COWL 435AL.
3. INSTALL PLATFORMS TO GAIN ACCESS TO VARIOUS
DE-ICERS.

002

___________________________________
OPENING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000

003

ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


___________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

004

______________________
CHECK
OF MFC OPERATION
1. ON PANEL 25VU, CHECK THAT THE FOLLOWING
PUSHBUTTON SWITCHES ARE PRESSED
(OFF LEGENDS ARE OFF):
6UA1
6UA2
7UA1
7UA2

005

MFC/1B/FAULT/OFF
MFC/2B/FAULT/OFF
MFC/1A/FAULT/OFF
MFC/2A/FAULT/OFF

_____________________________________
OPERATIONAL
TEST OF AIRFRAME DE-ICING
REF. FIG. 301100-OPT-00100
301100-OPT-00110
1. TO PERFORM TEST, CONNECT GROUND AIR PRESSURIZATION UNIT 4 BARS (58 PSI) (60 L/SEC)
TO LEFT REGULATOR VALVE TEST PORT 1.
*** CONTINUED ***
AH

30-11-00
OPT 10060-003
2-400 PAGE
2
DEC 01/14

30-11-00

OPERATIONAL TEST OF
AIRFRAME DE-ICING

OPT 10060-003
3

DEC14

NOTE : THIS TEST CAN BE PERFORMED ALSO WITH


ROTATING ENGINE. ENGINE COWLS CLOSED.
AFTER AN ENGINE REPLACEMENT, PERFORM
TEST DURING ENGINE ADJUSTMENT AT
RUN-UP.
2. ON PANEL 702VU,
PLACE SWITCH WEIGHT ON WHEELS IN FLT
POSITION.
3. ON PANEL 24VU,
A. CHECK THAT AFR AIR BLEED
PUSHBUTTON SWITCH (2) IS PRESSED :
-FAULT LEGEND OFF,
-OFF LEGEND OFF.
B. .PRESS AIRFRAME PUSHBUTTON SWITCH (3) :
-FAULT LEGEND OFF,
-ON LEGEND ON.
.ON MFD, IN TEMPORARY SELECTION WINDOW,
CYAN AIRFRAME MESSAGE IS DISPLAYED.
4. WAIT 3MN, NO WARNINGS MUST APPEAR.
NOTE : PERFORM THIS TEST ONLY WHEN THIS TEST
IS PERFORMED WITH A COMPRESSOR.
CHECK MANUALLY AND AURALLY FOR AIR
LEAKAGE AT LEVEL OF ELEMENT REMOVED.
CHECK VISUALLY DE-ICER INFLATING.
5.A. ON PANEL 24VU,
REALEASE AIRFRAME PUSHBUTTON SWITCH (3):
-FAULT LEGEND OFF,
-ON LEGEND OFF.
B. ON MFD, IN TEMPORARY SELECTION WINDOW,
AIRFRAME MESSAGE DISAPPEARS.
6. ON PANEL 702VU,
PLACE SWITCH WEIGHT ON WHEELS IN NORM
POSITION.
*** CONTINUED ***
AH

30-11-00
OPT 10060-003
2-400 PAGE
3
DEC 01/14

30-11-00

OPERATIONAL TEST OF
AIRFRAME DE-ICING

OPT 10060-003
4

DEC14

7. DISCONNECT GROUND AIR PRESSURIZATION UNIT


OR SHUTT OFF ENGINE.
8. INSTALL PROTECTIVE PLUG ON REGULATOR
VALVE TEST PORT.
006

DE-ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


______________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

007

________
CLOSE-UP
1. CHECK THAT WORKING AREA IS CLEAN AND CLEAR
OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
2. REMOVE ACCESS PLATFORM AFTER CLOSING ENGINE
COWLS 435AL AS FOLLOWS :

008

___________________________________
CLOSING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000
*****

AH

E N D

O F

T E X T

*****

30-11-00
OPT 10060-003
2-400 PAGE
4
DEC 01/14

30-11-00
5

AH

CONTROLS AND INDICATING


WING/ENGINE DE ICING

OPT 10060-003
DEC14

30-11-00
OPT 10060-003

2-400

PAGE
5
DEC 01/14

30-11-00
6

AH

TEST COUPLING - PRESSURE


REGULATOR AND SHUT-OFF
VALVE

OPT 10060-003
DEC14

30-11-00
OPT 10060-003

2-400

PAGE
6
DEC 01/14

30-11-00

REPAIR OF PNEUMATIC
DE-ICERS

REP 10040-001
1

MAR12

ZONING DATA
___________
ZONE

: 331
451
511
611

341
461
513
613

515
615

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

GSE

: 01 ACCESS PLATFORM
01 ROLLER

BULK MATERIAL : EMERY CLOTH FINE GRADE 150


METHYL-ETHYL-CETONE
CEMENT
FABR-REINF POLYURETH PATCH

_________
MAN-HOURS

11-003
08-018

PUBLICATION
___________
JIC

: OPERATIONAL TEST OF AIR


FOIL DE-ICING SYSTEM

AH

30-11-00-OPT-10000

30-11-00
REP 10040-001
2-400 PAGE
1
MAR 01/12

30-11-00

REPAIR OF PNEUMATIC
DE-ICERS

001

REP 10040-001
2

MAR12

___________
PREPARATION
1. POSITION ACCESS PLATFORM, TO GAIN ACCESS TO
DAMAGED DE-ICER.

002

____________________________
REPAIR
OF PNEUMATIC DE-ICERS
REF. FIG. 301100-REP-00101
IN ORDER TO BE EFFECTIVE AND DURABLE, THE
REPAIRS DESCRIBED BELOW SHOULD BE CARRIED OUT
WITH CARE BY QUALIFIED PERSONNEL.
REFER TO CMM VENDOR REPAIR SECTION OF PNEUMATIC
DE-ICER:
ATR 42: 30-11-41 AND 30-21-64
ATR 72: 30-11-42 AND 30-21-65

003

OPERATIONAL TEST OF AIR FOIL DE-ICING SYSTEM


____________________________________________
WITH EACH REGULATOR VALVE
_________________________
SEE JOB INSTRUCTION CARD
301100-OPT-10000

004

________
CLOSE-UP
1. MAKE CERTAIN THAT WORKING AREA IS CLEAN AND
CLEAR OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
2. REMOVE ACCESS PLATFORM.
*****

AH

E N D

O F

T E X T

*****

30-11-00
REP 10040-001
2-400 PAGE
2
MAR 01/12

30-11-00
3

AH

REPAIR OF PNEUMATIC
DE-ICERS

REP 10040-001
MAR12

30-11-00
REP 10040-001

2-400

PAGE
3
MAR 01/12

30-11-00

SERVICING OF PNEUMATIC
DE-ICERS

SRV 10020-001
1

APR05

ZONING DATA
___________
ZONE
ACCESS

: 511
611
: 331

513
613
341

515

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

GSE

: 01 ACCESS PLATFORM 3M (10FT)


01 ACCESS PLATFORM 4M (13FT)
01 ACCESS PLATFORM 7M (23FT)

_________
MAN-HOURS

BULK MATERIAL : NON ACID CASTILE TYPE SOAP


UNLEADED PETROL

AH

30-11-00
SRV 10020-001
2-400 PAGE
1
APR 01/05

30-11-00

SERVICING OF PNEUMATIC
DE-ICERS

001

SRV 10020-001
2

APR05

___________
PREPARATION
1. POSITION ACCESS PLATFORMS 3,00 M (10 FT) OR
3.5 M (12 FT) OR 7,00 M (23 FT) TO GAIN
ACCESS TO PNEUMATIC DE-ICERS.

002

_______________________________
SERVICING
OF PNEUMATIC DE-ICERS
REF. FIG. 301100-SRV-00101
1. SERVICING OF PNEUMATIC DE-ICERS
A. RECOMMENDATIONS
(1)THE DE-ICERS ARE SUBJECTED TO INTENSE
ABRASION DUE TO SAND, DUST AND ADVERSE
CONDITIONS. IT IS THEREFORE IMPORTANT
TO AVOID ANY OTHER TYPE OF DAMAGE SUCH
AS DENTS OR SCRATCHES CAUSED BY MAINTENANCE TOOLS.
B. SERVICING
(1)BECAUSE OF THEIR POSITION, CERTAIN
DE-ICERS ARE CONTAMINATED BY ENGINE
OIL, HYDRAULIC FLUID AND EXHAUST GASES. THEY SHALL BE CLEANED WHEN THEY
ARE VERY CONTAMINATED OR WHEN THE
AIRCRAFT IS CLEANED, WITH NON-ACID
SOAP (CASTILE SOAP) OR UNLEADED PETROL. USE UNLEADED PETROL SPARINGLY.
C. CLEANING PROCEDURE
(1)CLEAN DE-ICER OUTER SURFACES USING A
CLEAN CLOTH SOAKED WITH WATER AND
NON-ACID SOAP (CASTILE SOAP).
(2)CLEAN AREAS CONTAMINATED BY OIL OR
HYDRAULIC FLUID WITH PARTICULAR
ATTENTION.
(3)THOROUGLY RINSE WITH CLEAN WATER.

*** CONTINUED ***


AH

30-11-00
SRV 10020-001
2-400 PAGE
2
APR 01/05

30-11-00

SERVICING OF PNEUMATIC
DE-ICERS

003

SRV 10020-001
3

APR05

________
CLOSE-UP
1. MAKE CERTAIN THAT WORKING AREA IS CLEAN
AND CLEAR OF TOOLS AND MISCELLANEOUS
ITEMS OF EQUIPMENT.
2. REMOVE ACCESS PLATFORMS.
*****

AH

E N D

O F

T E X T

*****

30-11-00
SRV 10020-001
2-400 PAGE
3
APR 01/05

30-11-00
4

AH

PNEUMATIC DE-ICERS
LOCATION

SRV 10020-001
APR05

30-11-00
SRV 10020-001

2-400

PAGE
4
APR 01/05

30-11-31

REMOVAL/INSTALLATION OF
EMPENNAGE DUAL
DISTRIBUTOR VALVE

RAI 10000-001
1

MAR14

ZONING DATA
___________
ZONE
ACCESS

: 311
: 835

851

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

GSE

: 01 STEP LADDER

SPARE

: 01 VALVE-DE ICING DUAL

301130-04-090

EXPENDABLE

: 01 O-RING
02 O-RING

301130-08-040
301130-08-160

BULK MATERIAL : GREASE

_________
MAN-HOURS

04-004

PUBLICATION
___________
JIC
JIC

: OPERATIONAL TEST OF AIR


FOIL DE-ICING SYSTEM
: FUNCTIONAL TEST OF
ELECTRICAL HEATERS

AH

30-11-00-OPT-10000
30-11-00-FUT-10000

30-11-31
RAI 10000-001
2-400 PAGE
1
MAR 01/14

30-11-31

REMOVAL/INSTALLATION OF
EMPENNAGE DUAL
DISTRIBUTOR VALVE

001

RAI 10000-001
2

MAR14

___________
PREPARATION
1. ON PANEL 122VU, OPEN, SAFETY AND TAG THE
FOLLOWING CIRCUIT BREAKERS:
2DM
3DM
52DM

ANTI/DE ICING/ENG2 & AFR BOOTS B/NORM


SPLY & V HTG CTL
ANTI/DE ICING/ENG1 & AFR BOOTS A/SPLY
ANTI/DE ICING/ENG2 & AFR BOOTS B/EMER
SPLY

2. OPEN ACCESS DOOR 835 (IF ATR 42 STANDARD) OR


DOOR 851 (IF ATR 72 STANDARD).
3. INSTALL STEP LADDER TO GAIN ACCES TO
EMPENNAGE DUAL DISTRIBUTOR VALVE 11DM
LOCATED IN REAR CONE AFTER SEALED BULKHEAD.
002

REMOVAL OF EMPENNAGE
____________________
DUAL DISTRIBUTOR VALVE
______________________
REF. FIG. 301131-RAI-00100
1. DISCONNECT ELECTRICAL CONNECTORS (14) AND
(15).
2. REMOVE CLAMP (24) AND SUPPLY LINE (13).
3. DISCONNECT DISTRIBUTION LINES (11) AND (12).
4. REMOVE SCREWS (9) AND WASHERS (10).
5. REMOVE DUAL VALVE DISTRIBUTOR.
6. INSTALL BLANKING CAP ON LINES AND ELECTRICAL
CONNECTORS.
7. REMOVE COUPLING (1), (2) AND (5) WITH THEIR
O-RINGS (3), (4) AND (6).

*** CONTINUED ***


AH

30-11-31
RAI 10000-001
2-400 PAGE
2
MAR 01/14

30-11-31

REMOVAL/INSTALLATION OF
EMPENNAGE DUAL
DISTRIBUTOR VALVE

003

RAI 10000-001
3

MAR14

INSTALLATION OF EMPENNAGE
_________________________
DUAL DISTRIBUTOR VALVE
______________________
REF. FIG. 301131-RAI-00100
1. INSTALL ELBOW COUPLINGS (1), (2) AND (5)
EQUIPPED WITH THEIR NUTS (7), (8) AND (16)
AND THEIR O-RING (3), (4) ET (6). APPLY SYNTHETIC GREASE 04-004 ON COUPLING THREADS.
2. ADJUST COUPLINGS AT THEORETICAL DIMENSION XX
MORE OR LESS 1 TURN (COUPLING AXIS TO CONTACT OF VALVE).
3. DON}T TIGHTEN NUTS (7), (8) AND (16).
4. CLEAN AND INSPECT COMPONENT INTERFACE AND/OR
ADJACENT AREA.
5. REMOVE BLANKING CAP.
6. INSTALL DUAL VALVE DISTRIBUTOR WITH SCREWS
(9) AND WASHERS (10), AND INSTALL LEAD
BONDING (17).
WARNING : MAINTAIN 18MM MINIMUM BETWEEN LINES
AND FLIGHT CONTROL, AND LINES AND
BRACKETS.
7. ALIGN ELBOW COUPLINGS (1) AND (2) WITH LINES
(11) AND (12) WITHOUT CONNECTING LINES.
8. TIGHTEN NUTS (7) AND (8). (TIGHTENING TORQUE
35.4 TO 39.09 LBF.FT/4.8 TO 5.3 M.DAN).
9. INSTALL LINE (13) WITHOUT TIGHTEN.
10.ALIGN COUPLING (5) WITH LINE (16) WITHOUT
CONNECTING LINE.
11.CHECK THAT LINE/COUPLING ASSY MAKE 10
*** CONTINUED ***
AH

30-11-31
RAI 10000-001
2-400 PAGE
3
MAR 01/14

30-11-31

REMOVAL/INSTALLATION OF
EMPENNAGE DUAL
DISTRIBUTOR VALVE

RAI 10000-001
4

MAR14

DEGREES ANGLE WITH RESPECT HORIZONTAL.


12.TIGHTEN NUT (16). (TIGHTENING TORQUE 35.4 TO
39.09 LBF.FT/4.8 TO 5.3 M.DAN).
13.CONNECT SUPPLY LINE (13). (TIGHTENING TORQUE
35.4 TO 39.09 LBF.FT/4.8 TO 5.3 M.DAN).
14.INSTALL CLAMP (24).
15.CONNECT ELECTRICAL CONNECTORS (14) AND
(15).
004

OPERATIONAL TEST OF AIR FOIL DE-ICING SYSTEM


____________________________________________
WITH EACH REGULATOR VALVE
_________________________
SEE JOB INSTRUCTION CARD
301100-OPT-10000

005

_____________________________________
FUNCTIONAL
TEST OF ELECTRICAL HEATERS
SEE JOB INSTRUCTION CARD
301100-FUT-10000

006

________
CLOSE-UP
1. CHECK THAT WORKING AREA IS CLEAN AND CLEAR
OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
2. CLOSE ACCESS DOOR PREVIOUSLY OPENED AND
REMOVE LADDER.
3. ON PANEL 122VU, CLOSE CIRCUIT BREAKERS
PREVIOUSLY OPENED.
*****

AH

E N D

O F

T E X T

*****

30-11-31
RAI 10000-001
2-400 PAGE
4
MAR 01/14

30-11-31
5

AH

DUAL DISTRIBUTOR
VALVE

RAI 10000-001
MAR14

30-11-31
RAI 10000-001

2-400

PAGE
5
MAR 01/14

30-11-33

OPERATIONAL TEST OF
EMPENNAGE WATER DRAIN
OPENING

OPT 10000-001
1

MAR11

ZONING DATA
___________
ZONE
ACCESS

: 263
310
435
445
: 435AL 445AL
851

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

GSE

: 03 ACCESS PLATFORM
01 COMPRESSOR

_________
MAN-HOURS

PUBLICATION
___________
JIC

: OPENING AND CLOSING OF


HINGED ENGINE COWLS

AH

54-00-00-OAC-10000

30-11-33
OPT 10000-001
2-400 PAGE
1
MAR 01/11

30-11-33

OPERATIONAL TEST OF
EMPENNAGE WATER DRAIN
OPENING

001

OPT 10000-001
2

MAR11

___________
PREPARATION
1. POSITION PLATFORM, TO GAIN ACCESS TO
VERTICAL STABILIZER WATER DRAIN (5037DM)
LOCATED IN REAR CONE AFTER SEALED BULKHEAD.
2. OPEN ACCESS DOOR 851.
3. INSTALL ACCESS PLATFORM, SO AS TO HAVE
ACCESS TO FOLLOWING EQUIPMENT :
- ON ENGINE L(R)
. VALVE SHUT OFF REGULATOR 13DM (14DM).
4. OPEN ENGINE COWLS 435AL AND 445AL.

002

___________________________________
OPENING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000

003

_____________________________________
OPERATIONAL
TEST OF PIPE WATER DRAINS
REF. FIG. 301133.OPT-00100
301100-OPT-00110
1. UNSCREW AND REMOVE PROTECTIVE PLUG FROM
REGULATOR VALVE TEST PORT.
2. TO PERFORM TEST,CONNECT COMPRESSOR 4 BARS
(58 PSI) (60 L/SEC) TO LEFT (RIGHT) ENGINE
REGULATOR AND SHUT-OFF VALVE TEST PLUG.
3. BLEED CIRCUIT WITH GROUND AIR PRESSURIZATION
UNIT.
4. INCREASE PRESSURE FROM 0 TO 0.400 BAR (5.8
PSI). CHECK THAT AIR FLOWS THROUGH EACH
DRAIN (DRAIN OPEN).
5. CONTINUE TO INCREASE PRESSURE FROM 0.400
BAR TO 2 BAR (5.8 TO 29 PSI). CHECK THAT
*** CONTINUED ***
AH

30-11-33
OPT 10000-001
2-400 PAGE
2
MAR 01/11

30-11-33

OPERATIONAL TEST OF
EMPENNAGE WATER DRAIN
OPENING

OPT 10000-001
3

MAR11

AIR DOES NOT FLOW THROUGH DRAINS (DRAIN


CLOSED).
6. DECREASE PRESSURE TO 0 BAR (0 PSI).
7. DISCONNECT GROUND AIR PRESSURIZATION UNIT
FROM LEFT (RIGHT) REGULATOR VALVE.
8. INSTALL PROTECTIVE PLUG ON REGULATOR VALVE
TEST PORT.
004

________
CLOSE-UP
1. CLOSE ACCESS DOOR 851 AND REMOVE ACCESS
PLATFORM.
2. CHECK THAT WORKING AREA IS CLEAN AND CLEAR
OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
3. REMOVE ACCESS PLATFORM, AFTER CLOSING
ENGINES COWLS 435AL AND 445AL.

005

___________________________________
CLOSING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000
*****

AH

E N D

O F

T E X T

*****

30-11-33
OPT 10000-001
2-400 PAGE
3
MAR 01/11

30-11-33
4

AH

OPERATIONAL TEST OF
WATER DRAIN OPENING

OPT 10000-001
MAR11

30-11-33
OPT 10000-001

2-400

PAGE
4
MAR 01/11

30-11-33
5

AH

TEST COUPLING - PRESSURE


REGULATOR AND SHUT-OFF
VALVE

OPT 10000-001
MAR11

30-11-33
OPT 10000-001

2-400

PAGE
5
MAR 01/11

30-11-33

OPERATIONAL TEST OF
EMPENNAGE WATER DRAIN
OPENING

OPT 10000-002
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 263
310
435
445
: 435AL 445AL
851

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

GSE

: 03 ACCESS PLATFORM
01 COMPRESSOR

_________
MAN-HOURS

PUBLICATION
___________
JIC

: OPENING AND CLOSING OF


HINGED ENGINE COWLS

AH

54-00-00-OAC-10000

30-11-33
OPT 10000-002
2-400 PAGE
1
DEC 01/14

30-11-33

OPERATIONAL TEST OF
EMPENNAGE WATER DRAIN
OPENING

001

OPT 10000-002
2

DEC14

___________
PREPARATION
1. POSITION PLATFORM, TO GAIN ACCESS TO
VERTICAL STABILIZER WATER DRAIN (5037DM)
LOCATED IN REAR CONE AFTER SEALED BULKHEAD.
2. OPEN ACCESS DOOR 851.
3. INSTALL ACCESS PLATFORM, SO AS TO HAVE
ACCESS TO FOLLOWING EQUIPMENT :
- ON ENGINE L(R)
. VALVE SHUT OFF REGULATOR 13DM (14DM).
4. OPEN ENGINE COWLS 435AL AND 445AL.

002

___________________________________
OPENING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000

003

_____________________________________
OPERATIONAL
TEST OF PIPE WATER DRAINS
REF. FIG. 301133.OPT-00100
301100-OPT-00110
1. UNSCREW AND REMOVE PROTECTIVE PLUG FROM
REGULATOR VALVE TEST PORT.
2. TO PERFORM TEST,CONNECT GROUND AIR PRESSURIZATION UNIT 4 BARS (58 PSI) (60 L/SEC)
TO LEFT REGULATOR VALVE TEST PORT 1.
3. BLEED CIRCUIT WITH GROUND AIR PRESSURIZATION
UNIT.
4. INCREASE PRESSURE FROM 0 TO 0.400 BAR (5.8
PSI). CHECK THAT AIR FLOWS THROUGH EACH
DRAIN (DRAIN OPEN).
5. CONTINUE TO INCREASE PRESSURE FROM 0.400
BAR TO 2 BAR (5.8 TO 29 PSI). CHECK THAT
*** CONTINUED ***
AH

30-11-33
OPT 10000-002
2-400 PAGE
2
DEC 01/14

30-11-33

OPERATIONAL TEST OF
EMPENNAGE WATER DRAIN
OPENING

OPT 10000-002
3

DEC14

AIR DOES NOT FLOW THROUGH DRAINS (DRAIN


CLOSED).
6. DECREASE PRESSURE TO 0 BAR (0 PSI).
7. DISCONNECT GROUND AIR PRESSURIZATION UNIT
FROM LEFT (RIGHT) REGULATOR VALVE.
8. INSTALL PROTECTIVE PLUG ON REGULATOR VALVE
TEST PORT.
004

________
CLOSE-UP
1. CLOSE ACCESS DOOR 851 AND REMOVE ACCESS
PLATFORM.
2. CHECK THAT WORKING AREA IS CLEAN AND CLEAR
OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
3. REMOVE ACCESS PLATFORM, AFTER CLOSING
ENGINES COWLS 435AL AND 445AL.

005

___________________________________
CLOSING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000
*****

AH

E N D

O F

T E X T

*****

30-11-33
OPT 10000-002
2-400 PAGE
3
DEC 01/14

30-11-33
4

AH

OPERATIONAL TEST OF
WATER DRAIN OPENING

OPT 10000-002
DEC14

30-11-33
OPT 10000-002

2-400

PAGE
4
DEC 01/14

30-11-33
5

AH

TEST COUPLING - PRESSURE


REGULATOR AND SHUT-OFF
VALVE

OPT 10000-002
DEC14

30-11-33
OPT 10000-002

2-400

PAGE
5
DEC 01/14

30-11-33

REMOVAL/INSTALLATION OF
EMPENNAGE PIPES WATER
DRAIN

RAI 10010-001
1

MAR12

ZONING DATA
___________
ZONE
ACCESS

: 311
: 851

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
MECHANIC

ELAPSED TIME

GSE

: 01 STEP LADDER

SPARE

: 01 WATER DRAIN

EXPENDABLE

: 01 LOCK WIRE

___
MEN

_________
MAN-HOURS
01

BULK MATERIAL : GREASE

30-11-20

04-019

PUBLICATION
___________
JIC

: OPERATIONAL TEST OF
EMPENNAGE WATER DRAIN
OPENING

AH

30-11-33-OPT-10000

30-11-33
RAI 10010-001
2-400 PAGE
1
MAR 01/12

30-11-33

REMOVAL/INSTALLATION OF
EMPENNAGE PIPES WATER
DRAIN

001

RAI 10010-001
2

MAR12

___________
PREPARATION
1. OPEN ACCESS DOOR 851.
2. INSTALL A STEP LADDER TO GAIN ACCESS IN
REAR CONE.
3. INSTALL A STEP LADDER IN REAR CONE TO GAIN
ACCESS TO WATER DRAIN 5037DM.

002

_______________________
REMOVAL
OF WATER DRAINS
REF. FIG. 301133-RAI-00110
1. CUT AND REMOVE THE LOCK WIRE
2. BY MEANS OF AN OPEN SPANNER, LOOSEN NUT (1)
AND REMOVE WATER DRAIN (2).
3. BLANK OPEN AIR DUCT.
NOTE : EXAMPLE OF REMOVAL AND INSTALLATION OF
WATER DRAIN. PROCEDURE IS IDENTICAL FOR
ALL WATER DRAINS.

003

____________________________
INSTALLATION
OF WATER DRAINS
REF. FIG. 301133-RAI-00110
1. CLEAN AND INSPECT COMPONENT INTERFACE AND/OR
ADJACENT AREA.
2. COAT WATER DRAIN THREAD WITH MATERIAL 04-019
INSTALL WATER DRAIN (2) ON AIR DUCT. TORQUE
NUT (1) TO BETWEEN 1.2 MINI AND 1.5 MDAN MAXI(106.2 LBF.IN.MINI AND 132.75 LBF.IN.MAXI)
3. CHECK FOR CORRECT INSTALLATION.
INSTALL THE LOCK WIRE.
*** CONTINUED ***
AH

30-11-33
RAI 10010-001
2-400 PAGE
2
MAR 01/12

30-11-33

REMOVAL/INSTALLATION OF
EMPENNAGE PIPES WATER
DRAIN

004

RAI 10010-001
3

MAR12

_______________________________________
OPERATIONAL
TEST OF WATER DRAIN OPENING
SEE JOB INSTRUCTION CARD
301133-OPT-10000.

005

________
CLOSE-UP
1. MAKE CERTAIN THAT WORKING AREA IS CLEAN AND
CLEAR OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
2. REMOVE STEP LADDER.
3. CLOSE ACCESS.
*****

AH

E N D

O F

T E X T

*****

30-11-33
RAI 10010-001
2-400 PAGE
3
MAR 01/12

30-11-33
4

AH

REMOVAL/INSTALLATION
OF LINE WATER DRAINS

RAI 10010-001
MAR12

30-11-33
RAI 10010-001

2-400

PAGE
4
MAR 01/12

30-11-43

REMOVAL AND INSTALLATION


OF RUDDER HORN

RAI 10000-001
1

APR05

ZONING DATA
___________
ZONE
ACCESS

: 327
: 327TL

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

GSE

: 01 ACCESS PLATFORM

SPARE

: 01 RUDDER HORN

BULK MATERIAL : SPECIAL MATERIAL


GREASE
SEALING PRODUCT

_________
MAN-HOURS

301140-20-020
05-027
04-003
09-018

PUBLICATION
___________
JIC
JIC

: BALANCE OF RUDDER
DURING REPLACEMENT OF
THE DE-ICED HORN
: OPERATIONAL TEST OF
ANTI-ICING AND WARNING
OF EACH HORN

AH

55-40-00-ADJ-10000
30-11-00-OPT-10030

30-11-43
RAI 10000-001
2-400 PAGE
1
APR 01/05

30-11-43

REMOVAL AND INSTALLATION


OF RUDDER HORN

001

RAI 10000-001
2

APR05

___________
PREPARATION
1. POSITION ACCESS PLATFORM TOGAIN ACCESS TO
RUDDER HORN.
2. OPEN SAFETY AND TAG THE FOLLOWING CIRCUIT
BREAKERS:
ON PANEL 126VU,
51DM
HORNS ANTI ICING PWR SPLY/RUD
ON PANEL 122VU,
33DM
ANTI/DE ICING/HORNS CTL & IND/RUD
& L ELEV
CAUTION : INSTALL WARNING NOTICE IN FLIGHT
COMPARTMENT PROHIBITING OPERATION
OF RUDDER CONTROL.

002

______________________
REMOVAL
OF RUDDER HORN
REF. FIG. 301143-RAI-00100
1. REMOVE HORN ATTACHMENT SCREWS (3).
2. REMOVE HORN.
3. DISCONNECT ELECTRICAL CONNECTOR (1) AND
BONDING STRIP (2).
4. REMOVE ELECTRICAL CONNECTOR AND TAPE TO
RUDDER.

003

BALANCE OF RUDDER DURING REPLACEMENT OF THE


___________________________________________
DE-ICED HORN
____________
SEE JOB INSTRUCTION CARD
554000-ADJ-10000

*** CONTINUED ***


AH

30-11-43
RAI 10000-001
2-400 PAGE
2
APR 01/05

30-11-43

REMOVAL AND INSTALLATION


OF RUDDER HORN

004

RAI 10000-001
3

APR05

___________________________
INSTALLATION
OF RUDDER HORN
REF. FIG. 301143-RAI-00100
1. CHECK FOR CORRECT CONDITION OF ELECTRICAL
CONNECTOR AND VISIBLE SECTION OF WIRING.
PROTECT ELECTRICAL CONNECTOR AND CONNECTOR
SOCKET WITH MATERIAL N0. 05-027.
CHECK FOR ABSENCE OF CORROSION IN HORN INSTALLATION AREA.
2. COAT THREADS OF CAPTIVE NUTS WITH MATERIAL
N0. 04-003.
3. CONNECT ELECTRICAL CONNECTOR (1) AND BONDING
STRIP (2).
4. COAT THE SURFACE WHESE THE HORN MUST BE
INSTALLED WITH SEALING PRODUCT N0. 09-018.
INSTALL HORN ON RUDDER. INSTALL AND TIGHTEN
SCREWS (3).

005

OPERATIONAL TEST OF HORN ANTI ICING


___________________________________
AND WARNING
___________
SEE JOB INSTRUCTION CARD
301100-OPT-10030

006

________
CLOSE-UP
1. MAKE CERTAIN THAT WORKING AREA IS CLEAN AND
CLEAR OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
2. REMOVE ACCESS PLATFORM.
*****

AH

E N D

O F

T E X T

*****

30-11-43
RAI 10000-001
2-400 PAGE
3
APR 01/05

30-11-43
4

AH

REMOVAL AND INSTALLATION


OF RUDDER ANTI ICING
HORN

RAI 10000-001
APR05

30-11-43
RAI 10000-001

2-400

PAGE
4
APR 01/05

30-11-44

REMOVAL AND INSTALLATION


OF ELEVATOR HORN

RAI 10000-001
1

APR05

ZONING DATA
___________
ZONE
ACCESS

: 334
344
: 334AL 344AR

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

GSE

: 01 ACCESS PLATFORM

SPARE

: 01 LEFT ELEVATOR HORN


01 RIGHT ELEVATOR HORN

BULK MATERIAL : SPECIAL MATERIAL


GREASE
SEALING PRODUCT

_________
MAN-HOURS

301140-15-030
301140-15-040
05-027
04-003
09-018

PUBLICATION
___________
JIC
JIC

: BALANCE OF ELEVATORS
DURING REPLACEMENT OF
THE DE-ICED HORNS
: OPERATIONAL TEST OF
ANTI-ICING AND WARNING
OF EACH HORN

AH

55-20-00-ADJ-10000
30-11-00-OPT-10030

30-11-44
RAI 10000-001
2-400 PAGE
1
APR 01/05

30-11-44

REMOVAL AND INSTALLATION


OF ELEVATOR HORN

001

RAI 10000-001
2

APR05

___________
PREPARATION
1. POSITION ACCESS PLATFORM TO GAIN ACCESS TO
ELEVATOR HORNS.
2. OPEN SAFETY AND TAG THE FOLLOWING CICUIT
BREAKER:
ON PANEL
63DM
32DM
ON PANEL
33DM
34DM

126VU,
HORNS ANTI ICING PWR SPLY/L ELEV
HORNS ANTI ICING PWR SPLY/R ELEV
122VU,
ANTI/DE ICING/HORNS CTL & IND/RUD &
L ELEV
ANTI/DE ICING/HORNS CTL & IND/AIL &
R ELEV

CAUTION : INSTALL WARNING NOTICE IN FLIGHT


COMPARTMENT PROHIBITING OPERATION OF
ELEVATOR CONTROL.
002

________________________
REMOVAL
OF ELEVATOR HORN
REF. FIG. 301144-RAI-00100
1. REMOVE HORN ATTACHMENT SCREWS (1).
2. REMOVE HORN.
3. DISCONNECT ELECTRICAL CONNECTOR (2).
4. CAP ELECTRICAL CONNECTOR AND TAPE TO ELEVATOR.
NOTE : THIS REMOVAL PROCEDURE CONCERNS LEFT
HORN. REMOVAL OF RIGHT HORN IS
IDENTICAL.

*** CONTINUED ***


AH

30-11-44
RAI 10000-001
2-400 PAGE
2
APR 01/05

30-11-44

REMOVAL AND INSTALLATION


OF ELEVATOR HORN

003

RAI 10000-001
3

APR05

BALANCE OF ELEVATORS DURING REPLACEMENT OF THE


______________________________________________
DE-ICED HORNS
_____________
SEE JOB INSTRUCTION CARD
552000-ADJ-10000

004

_____________________________
INSTALLATION
OF ELEVATOR HORN
REF. FIG. 301144-RAI-00100
1. CHECK FOR CORRECT CONDITION OF ELECTRICAL
CONNECTOR AND VISIBLE SECTION OF WIRING.
PROTECT CONNECTOR AND CONNECTOR SOCKET WITH
MATERIAL N0. 05-027.
CHECK FOR ABSENCE OF CORROSION IN HORN
INSTALLATION AREA.
2. COAT THREADS OF CAPTIVE NUTS (3) WITH
MATERIAL N0. 04-003.
3. CONNECT CONNECTOR (2).
4. COAT THE SURFACE WHESE THE HORN MUST BE
INSTALLED WITH SEALING PRODUCT N0. 09-018.
INSTALL HORN ON ELEVATOR. INSTALL AND
TIGHTEN SCREWS (1).
NOTE : THIS INSTALLATION PROCEDURE CONCERNS
LEFT HORN. INSTALLATION OF RIGHT HORN
IS IDENTICAL.

005

OPERATIONAL TEST OF HORN ANTI ICING


___________________________________
AND WARNING
___________
SEE JOB INSTRUCTION CARD
301100-OPT-10030

006

________
CLOSE-UP
1. MAKE CERTAIN THAT WORKING AREA IS CLEAN AND
CLEAR OF TOOLS AND MISCELLANEOUS ITEMS OF
*** CONTINUED ***
AH

30-11-44
RAI 10000-001
2-400 PAGE
3
APR 01/05

30-11-44

REMOVAL AND INSTALLATION


OF ELEVATOR HORN

RAI 10000-001
4

APR05

EQUIPMENT.
2. REMOVE ACCESS PLATFORM.
*****

AH

E N D

O F

T E X T

*****

30-11-44
RAI 10000-001
2-400 PAGE
4
APR 01/05

30-11-44
5

AH

REMOVAL AND INSTALLATION


OF ELEVATOR HORNS

RAI 10000-001
APR05

30-11-44
RAI 10000-001

2-400

PAGE
5
APR 01/05

30-11-61

OPERATIONAL TEST OF REGU


LATOR AND SHUT OFF VALVE
BY USING ENG FIRE HANDLE

OPT 10000-005
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 435
445
: 435AL 445AL

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

GSE

: 02 ACCESS PLATFORM
01 COMPRESSOR

_________
MAN-HOURS

PUBLICATION
___________
JIC
JIC
JIC
JIC

: OPENING AND CLOSING OF


HINGED ENGINE COWLS
: DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY
: READING OF MFC
MAINTENANCE MEMORY
: ERASURE OF MFC
MAINTENANCE MEMORY

AH

54-00-00-OAC-10000
24-46-00-EAD-10000
45-13-00-RDG-10000
45-13-00-RON-10000

30-11-61
OPT 10000-005
2-400 PAGE
1
DEC 01/14

30-11-61

OPERATIONAL TEST OF REGU


LATOR AND SHUT OFF VALVE
BY USING ENG FIRE HANDLE

001

OPT 10000-005
2

DEC14

___________
PREPARATION
1. INSTALL PLATFORM TO HAVE ACCESS TO THE
FOLLOWING EQUIPMENTS :
ON ENGINE L (R)
. VALVE SHUT OFF REGULATOR
2. OPEN ENGINE COWLS 435AL(445AL).

002

DE-ENERGIZATION OF ENGINE FIRE EXTINGUISHING


____________________________________________
SYSTEM
______
OPEN, SAFETY AND TAG THE FOLLOWING CIRCUIT
BREAKERS :
- ON PANEL 122VU
1WE
2WE
3WE
4WE

003

ENG FIRE/EXTING
L BTL SQUIBS
ENG FIRE/EXTING
R BTL/SQUIBS
ENG FIRE/EXTING
L BTL SQUIBS
ENG FIRE/EXTING
R BTL SQUIBS

CTL & IND/HOT SPLY/


CTL & IND/HOT SPLY/
CTL & IND/EMER SPLY/
CTL & IND/EMER SPLY/

___________________________________
OPENING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000

004

ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


___________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

005

_________________________________
READING
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RDG-10000
*** CONTINUED ***
AH

30-11-61
OPT 10000-005
2-400 PAGE
2
DEC 01/14

30-11-61

OPERATIONAL TEST OF REGU


LATOR AND SHUT OFF VALVE
BY USING ENG FIRE HANDLE

006

OPT 10000-005
3

DEC14

_________________________________
ERASURE
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RON-10000
NOTE:THIS TASK MUST BE PERFORMED ONLY IF FAULTS
RELATIVE TO THE SYSTEM TO BE CHECKED HAVE
BEEN RECORDED BY THE MFC MAINTENANCE
MEMORY.

007

OPERATIONAL TEST OF ENGINE ANTI ICING PRESSURE


______________________________________________
REGULATOR AND SHUTOFF VALVES AND ENGINE ANTI
____________________________________________
ICING SHUT OFF VALVES WITH ENGINE FIRE HANDLES
______________________________________________
REF. FIG. 301100-OPT-00100
301100-OPT-00110.
NOTE : FOLLOWING TEST IS AN OPERATIONAL TEST OF
PRESSURE REGULATOR AND SHUT-OFF VALVE
AND SHUT-OFF VALVE OF LEFT ENGINE.
1. TO PERFORM TEST, CONNECT COMPRESSOR 1,5 BARS
(21,75PSI) MINIMUM TO LEFT ENGINE REGULATOR
AND SHUT-OFF VALVE TEST PLUG.
2. ON PANEL 702VU,
PLACE SWITCH WEIGHT ON WHEELS IN FLT
POSITION.
3. ON PANEL 24VU,
A. CHECK THAT AFR AIR BLEED PUSHBUTTON
SWITCH (2) IS PRESSED (IN) :
- FAULT LEGEND OFF,
- OFF LEGEND OFF.
B. PRESS ENG1 AND ENG2 PUSHBUTTON
SWITCHES (6) AND (7) :
- FAULT LEGEND OFF,
- ON LEGEND ON.
*** CONTINUED ***
AH

30-11-61
OPT 10000-005
2-400 PAGE
3
DEC 01/14

OPERATIONAL TEST OF REGU


LATOR AND SHUT OFF VALVE
BY USING ENG FIRE HANDLE

30-11-61

OPT 10000-005
4

DEC14

C. PRESS AIRFRAME PUSHBUTTON SWITCH (3) :


- FAULT LEGEND OFF,
- ON LEGEND ON.
4. ON PANEL 402VU,
CHECK THAT DE ICING ANNUNCIATOR (4) IS ON.
5. DURING 3 OR 4 MINUTES, ALLOW CYCLE TO RUN.
- NO WARNING MUST APPEAR,
- CHECK VISUALLY THAT WING AND ENGINES
DE ICERS INFLATE.
6. LIFT MECHANICAL LOCKING SYSTEM OF ENG1
FIRE HANDLE.
PULL FIRE HANDLE.
7. ON PANEL 24VU,
ON AFR AIR BLEED PUSHBUTTON SWITCH (2) :
- FAULT LEGEND ON (AFTER 6S),
- OFF LEGEND OFF.
8. FOLLOWINGS WARNINGS APPEAR :
- ON CAP, ANTI ICING CAUTION LIGHT COMES
ON,
- CAUTION ANNUNCIATORS COME ON,
- SINGLE CHIME SOUNDS.
NOTE: SINGLE CHINE AND CAUTION LIGHTS
ARE INHIBITED IF C.L.A}S (CONDITION
LEVER ANGLE) ARE IN FTR (FEATHER)
POSITION.
9. ON PANEL 24VU,
ON ENG1 AND ENG2 PUSHBUTTON SWITCHES
(6) AND (7) :
- FAULT LEGEND LIGHT ILLUMINATED DURING
2,5S EVERY 60S WHEN MODE SEL SAT LESS
THEN -18 CELSIUS DEGREES (1) PUSHBUTTON
SWITCH IS DEPRESSED AND EVERY 240S WHEN
MODE SEL SAT LESS THEN -18 CELSIUS DEGREES
(1) PUSHBUTTON SWITCH IS PRESSED.
*** CONTINUED ***
AH

30-11-61
OPT 10000-005
2-400 PAGE
4
DEC 01/14

30-11-61

OPERATIONAL TEST OF REGU


LATOR AND SHUT OFF VALVE
BY USING ENG FIRE HANDLE

OPT 10000-005
5

DEC14

- ON LEGEND IS ON.


10.CHECK VISUALLY THAT WING AND EGINES DEICERS DO NOT INFLATE.
11.ON PANEL 24VU,
A. RELEASE AFR AIR BLEED PUSHBUTTON
SWITCH (2) :
- FAULT LEGEND OFF,
- OFF LEGEND ON.
B. ON AIRFRAME (3), ENG1 (6) AND ENG2
(7) PUSHBUTTON SWITCHES
- FAULT LEGEND ON,
- ON LEGEND ON.
12.WARNINS REMAINS ON.
13.ON PANEL 24VU,
A. PRESS AFR AIR BLEED PUSHBUTTON
SWITCH (2) :
- FAULT LEGEND ON,
- OFF LEGEND OFF.
B. RESET AIFRAME PUSHBUTTON SWITCH (3)
(OFF/ON) :
- FAULT LEGEND OFF,
- ON LEGEND ON.
C. RESET ENG1 AND ENG2 PUSHBUTTON
SWITCHES (6) AND (7) (OFF/ON):
- FAULT LEGEND LIGHT IS ILLUMINATED
DURING 2,5S EVERY 60S WHEN PUSHBUTTON
SWITCH (1) IS DEPRESSED AND 240S WHEN
THE PUSHBUTTON SWITCH (1) IS PRESSED.
- ON LEGEND IS ON.
14.PUSH ENG1 FIRE HANDLE, LOWER MECHANICAL
*** CONTINUED ***
AH

30-11-61
OPT 10000-005
2-400 PAGE
5
DEC 01/14

30-11-61

OPERATIONAL TEST OF REGU


LATOR AND SHUT OFF VALVE
BY USING ENG FIRE HANDLE

OPT 10000-005
6

DEC14

LOCKING SYSTEM.
- ALL WARNING DISAPPEAR.
15.ON PANEL 24VU :
RELEASE AIRFRAME (3), ENG1 (6) AND
ENG2 (7) PUSHBUTTON SWITCHES
- FAULT LEGEND OFF,
- ON LEGEND OFF.
16.ON PANEL 402VU,
CHECK THAT DE ICING ANNUNCIATOR (4)
IS OFF.
17 ON PANEL 702VU,
PLACE SWITCH WEIGHT ON WHEELS IN NORM
POSITION.
18.DISCONNECT GROUND AIR PRESSURIZATION UNIT.
NOTE : FOR OPERATIONAL TEST OF PRESSURE
REGULATOR AND SHUT-OFF VALVE AND
SHUT-OFF VALVE OF RIGHT ENGINE,
REPEAT TEST ABOVE USING ENG2
FIRE HANDLE.
008

_________________________________
READING
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RDG-10000

009

_________________________________
ERASURE
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RON-10000

010

DE-ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


______________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000
*** CONTINUED ***
AH

30-11-61
OPT 10000-005
2-400 PAGE
6
DEC 01/14

30-11-61

OPERATIONAL TEST OF REGU


LATOR AND SHUT OFF VALVE
BY USING ENG FIRE HANDLE

011

OPT 10000-005
7

DEC14

________
CLOSE-UP
1. INSTALL BREAK WIRE ON MECHANICAL LOCKING
SYSTEM ON ENG1 AND ENG2 FIRE HANDLES
AND PLACE THE GARANTEE SEALING.
2. ON PANEL 122VU, REMOVE SAFETY TAGS AND
CLOSE THE CIRCUIT BREAKERS PREVIOUSLY
OPENED.
3. MAKE CERTAIN THAT WORKING AREA IS CLEAN
AND CLEAR OF TOOLS AND MISCELLANEOUS ITEMS
OF EQUIPMENT.
4. REMOVE PLATFORM AFTER CLOSING ENGINE COWLS
435AL (445AL).

012

___________________________________
CLOSING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000
*****

AH

E N D

O F

T E X T

*****

30-11-61
OPT 10000-005
2-400 PAGE
7
DEC 01/14

30-11-61
8

AH

CONTROLS AND INDICATING


WING/ENGINE DE ICING

OPT 10000-005
DEC14

30-11-61
OPT 10000-005

2-400

PAGE
8
DEC 01/14

30-11-61
9

AH

TEST COUPLING - PRESSURE


REGULATOR AND SHUT-OFF
VALVE

OPT 10000-005
DEC14

30-11-61
OPT 10000-005

2-400

PAGE
9
DEC 01/14

30-11-61

OPERATIONAL TEST OF REGU


LATOR AND SHUT OFF VALVE
BY USING ENG FIRE HANDLE

OPT 10000-006
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 435
445
: 435AL 445AL

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

GSE

: 02 ACCESS PLATFORM
01 COMPRESSOR

_________
MAN-HOURS

PUBLICATION
___________
JIC
JIC
JIC
JIC

: OPENING AND CLOSING OF


HINGED ENGINE COWLS
: DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY
: READING OF MFC
MAINTENANCE MEMORY
: ERASURE OF MFC
MAINTENANCE MEMORY

AH

54-00-00-OAC-10000
24-46-00-EAD-10000
45-13-00-RDG-10000
45-13-00-RON-10000

30-11-61
OPT 10000-006
2-400 PAGE
1
DEC 01/14

30-11-61

OPERATIONAL TEST OF REGU


LATOR AND SHUT OFF VALVE
BY USING ENG FIRE HANDLE

001

OPT 10000-006
2

DEC14

___________
PREPARATION
1. INSTALL PLATFORM TO HAVE ACCESS TO THE
FOLLOWING EQUIPMENTS :
ON ENGINE L (R)
. VALVE SHUT OFF REGULATOR
2. OPEN ENGINE COWLS 435AL(445AL).

002

DE-ENERGIZATION OF ENGINE FIRE EXTINGUISHING


____________________________________________
SYSTEM
______
OPEN, SAFETY AND TAG THE FOLLOWING CIRCUIT
BREAKERS :
- ON PANEL 122VU
1WE
2WE
3WE
4WE

003

ENG FIRE/EXTING
L BTL SQUIBS
ENG FIRE/EXTING
R BTL/SQUIBS
ENG FIRE/EXTING
L BTL SQUIBS
ENG FIRE/EXTING
R BTL SQUIBS

CTL & IND/HOT SPLY/


CTL & IND/HOT SPLY/
CTL & IND/EMER SPLY/
CTL & IND/EMER SPLY/

___________________________________
OPENING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000

004

ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


___________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

005

_________________________________
READING
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RDG-10000
*** CONTINUED ***
AH

30-11-61
OPT 10000-006
2-400 PAGE
2
DEC 01/14

30-11-61

OPERATIONAL TEST OF REGU


LATOR AND SHUT OFF VALVE
BY USING ENG FIRE HANDLE

006

OPT 10000-006
3

DEC14

_________________________________
ERASURE
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RON-10000
NOTE:THIS TASK MUST BE PERFORMED ONLY IF FAULTS
RELATIVE TO THE SYSTEM TO BE CHECKED HAVE
BEEN RECORDED BY THE MFC MAINTENANCE
MEMORY.

007

OPERATIONAL TEST OF ENGINE ANTI ICING PRESSURE


______________________________________________
REGULATOR AND SHUTOFF VALVES AND ENGINE ANTI
____________________________________________
ICING SHUT OFF VALVES WITH ENGINE FIRE HANDLES
______________________________________________
REF. FIG. 301100-OPT-00100
301100-OPT-00110.
NOTE : FOLLOWING TEST IS AN OPERATIONAL TEST OF
PRESSURE REGULATOR AND SHUT-OFF VALVE
AND SHUT-OFF VALVE OF LEFT ENGINE.
1. TO PERFORM TEST, CONNECT GROUND AIR PRESSURIZATION UNIT 4 BARS (58 PSI) (60L/SEC)
TO LEFT REGULATOR VALVE TEST PORT 1.
2. ON PANEL 702VU,
PLACE SWITCH WEIGHT ON WHEELS IN FLT
POSITION.
3. ON PANEL 24VU,
A. CHECK THAT AFR AIR BLEED PUSHBUTTON
SWITCH (2) IS PRESSED (IN) :
- FAULT LEGEND OFF,
- OFF LEGEND OFF.
B. PRESS ENG1 AND ENG2 PUSHBUTTON
SWITCHES (6) AND (7) :
- FAULT LEGEND OFF,
- ON LEGEND ON.
*** CONTINUED ***
AH

30-11-61
OPT 10000-006
2-400 PAGE
3
DEC 01/14

OPERATIONAL TEST OF REGU


LATOR AND SHUT OFF VALVE
BY USING ENG FIRE HANDLE

30-11-61

OPT 10000-006
4

DEC14

C. PRESS AIRFRAME PUSHBUTTON SWITCH (3) :


- FAULT LEGEND OFF,
- ON LEGEND ON.
4. ON PANEL 402VU,
CHECK THAT DE ICING ANNUNCIATOR (4) IS ON.
5. DURING 3 OR 4 MINUTES, ALLOW CYCLE TO RUN.
- NO WARNING MUST APPEAR,
- CHECK VISUALLY THAT WING AND ENGINES
DE ICERS INFLATE.
6. LIFT MECHANICAL LOCKING SYSTEM OF ENG1
FIRE HANDLE.
PULL FIRE HANDLE.
7. ON PANEL 24VU,
ON AFR AIR BLEED PUSHBUTTON SWITCH (2) :
- FAULT LEGEND ON (AFTER 6S),
- OFF LEGEND OFF.
8. FOLLOWINGS WARNINGS APPEAR :
- ON CAP, ANTI ICING CAUTION LIGHT COMES
ON,
- CAUTION ANNUNCIATORS COME ON,
- SINGLE CHIME SOUNDS.
NOTE: SINGLE CHINE AND CAUTION LIGHTS
ARE INHIBITED IF C.L.A}S (CONDITION
LEVER ANGLE) ARE IN FTR (FEATHER)
POSITION.
9. ON PANEL 24VU,
ON ENG1 AND ENG2 PUSHBUTTON SWITCHES
(6) AND (7) :
- FAULT LEGEND LIGHT ILLUMINATED DURING
2,5S EVERY 60S WHEN MODE SEL SAT LESS
THEN -18 CELSIUS DEGREES (1) PUSHBUTTON
SWITCH IS DEPRESSED AND EVERY 240S WHEN
MODE SEL SAT LESS THEN -18 CELSIUS DEGREES
(1) PUSHBUTTON SWITCH IS PRESSED.
*** CONTINUED ***
AH

30-11-61
OPT 10000-006
2-400 PAGE
4
DEC 01/14

30-11-61

OPERATIONAL TEST OF REGU


LATOR AND SHUT OFF VALVE
BY USING ENG FIRE HANDLE

OPT 10000-006
5

DEC14

- ON LEGEND IS ON.


10.CHECK VISUALLY THAT WING AND EGINES DEICERS DO NOT INFLATE.
11.ON PANEL 24VU,
A. RELEASE AFR AIR BLEED PUSHBUTTON
SWITCH (2) :
- FAULT LEGEND OFF,
- OFF LEGEND ON.
B. ON AIRFRAME (3), ENG1 (6) AND ENG2
(7) PUSHBUTTON SWITCHES
- FAULT LEGEND ON,
- ON LEGEND ON.
12.WARNINS REMAINS ON.
13.ON PANEL 24VU,
A. PRESS AFR AIR BLEED PUSHBUTTON
SWITCH (2) :
- FAULT LEGEND ON,
- OFF LEGEND OFF.
B. RESET AIFRAME PUSHBUTTON SWITCH (3)
(OFF/ON) :
- FAULT LEGEND OFF,
- ON LEGEND ON.
C. RESET ENG1 AND ENG2 PUSHBUTTON
SWITCHES (6) AND (7) (OFF/ON):
- FAULT LEGEND LIGHT IS ILLUMINATED
DURING 2,5S EVERY 60S WHEN PUSHBUTTON
SWITCH (1) IS DEPRESSED AND 240S WHEN
THE PUSHBUTTON SWITCH (1) IS PRESSED.
- ON LEGEND IS ON.
14.PUSH ENG1 FIRE HANDLE, LOWER MECHANICAL
*** CONTINUED ***
AH

30-11-61
OPT 10000-006
2-400 PAGE
5
DEC 01/14

30-11-61

OPERATIONAL TEST OF REGU


LATOR AND SHUT OFF VALVE
BY USING ENG FIRE HANDLE

OPT 10000-006
6

DEC14

LOCKING SYSTEM.
- ALL WARNING DISAPPEAR.
15.ON PANEL 24VU :
RELEASE AIRFRAME (3), ENG1 (6) AND
ENG2 (7) PUSHBUTTON SWITCHES
- FAULT LEGEND OFF,
- ON LEGEND OFF.
16.ON PANEL 402VU,
CHECK THAT DE ICING ANNUNCIATOR (4)
IS OFF.
17 ON PANEL 702VU,
PLACE SWITCH WEIGHT ON WHEELS IN NORM
POSITION.
18.DISCONNECT GROUND AIR PRESSURIZATION UNIT.
NOTE : FOR OPERATIONAL TEST OF PRESSURE
REGULATOR AND SHUT-OFF VALVE AND
SHUT-OFF VALVE OF RIGHT ENGINE,
REPEAT TEST ABOVE USING ENG2
FIRE HANDLE.
008

_________________________________
READING
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RDG-10000

009

_________________________________
ERASURE
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RON-10000

010

DE-ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


______________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000
*** CONTINUED ***
AH

30-11-61
OPT 10000-006
2-400 PAGE
6
DEC 01/14

30-11-61

OPERATIONAL TEST OF REGU


LATOR AND SHUT OFF VALVE
BY USING ENG FIRE HANDLE

011

OPT 10000-006
7

DEC14

________
CLOSE-UP
1. INSTALL BREAK WIRE ON MECHANICAL LOCKING
SYSTEM ON ENG1 AND ENG2 FIRE HANDLES
AND PLACE THE GARANTEE SEALING.
2. ON PANEL 122VU, REMOVE SAFETY TAGS AND
CLOSE THE CIRCUIT BREAKERS PREVIOUSLY
OPENED.
3. MAKE CERTAIN THAT WORKING AREA IS CLEAN
AND CLEAR OF TOOLS AND MISCELLANEOUS ITEMS
OF EQUIPMENT.
4. REMOVE PLATFORM AFTER CLOSING ENGINE COWLS
435AL (445AL).

012

___________________________________
CLOSING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000
*****

AH

E N D

O F

T E X T

*****

30-11-61
OPT 10000-006
2-400 PAGE
7
DEC 01/14

30-11-61
8

AH

CONTROLS AND INDICATING


WING/ENGINE DE ICING

OPT 10000-006
DEC14

30-11-61
OPT 10000-006

2-400

PAGE
8
DEC 01/14

30-11-61
9

AH

TEST COUPLING - PRESSURE


REGULATOR AND SHUT-OFF
VALVE

OPT 10000-006
DEC14

30-11-61
OPT 10000-006

2-400

PAGE
9
DEC 01/14

30-11-61

OPERATIONAL TEST OF REGU


LATOR AND SHUT OFF VALVE
BY USING ENG FIRE HANDLE

OPT 10000-007
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 435
445
: 435AL 445AL

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

GSE

: 02 ACCESS PLATFORM
01 COMPRESSOR

_________
MAN-HOURS

PUBLICATION
___________
JIC
JIC
JIC
JIC
JIC

: PRINCIPLE OF CDS USE


(DISPLAY UNITS
EXPLORATION)
: OPENING AND CLOSING OF
HINGED ENGINE COWLS
: DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY
: READING OF MFC
MAINTENANCE MEMORY
: ERASURE OF MFC
MAINTENANCE MEMORY

AH

31-63-00-PRO-10000
54-00-00-OAC-10000
24-46-00-EAD-10000
45-13-00-RDG-10000
45-13-00-RON-10000

30-11-61
OPT 10000-007
2-400 PAGE
1
DEC 01/14

30-11-61

OPERATIONAL TEST OF REGU


LATOR AND SHUT OFF VALVE
BY USING ENG FIRE HANDLE

001

OPT 10000-007
2

DEC14

PRINCIPLE OF CDS USE (DISPLAY UNITS


___________________________________
EXPLORATION)
____________
(TO USE ONLY IF NEEDED)
_______________________
SEE JOB INSTRUCTION CARD
316300-PRO-10000
NOTE: PROCEDURE TO USE ONLY IF NEEDED.
THIS PROCEDURE DESCRIBES LOCATION AND
MANAGEMENT OF THE DIFFERENT DISPLAY
WINDOWS PROVIDED BY THE THREE FORMATS
(PFD, EWD, MFD) PROPOSED ON THE FIVE
DISPLAY UNITS (DU).

002

___________
PREPARATION
1. INSTALL PLATFORM TO HAVE ACCESS TO THE
FOLLOWING EQUIPMENTS :
ON ENGINE L (R)
. VALVE SHUT OFF REGULATOR
2. OPEN ENGINE COWLS 435AL(445AL).

003

DE-ENERGIZATION OF ENGINE FIRE EXTINGUISHING


____________________________________________
SYSTEM
______
OPEN, SAFETY AND TAG THE FOLLOWING CIRCUIT
BREAKERS :
- ON PANEL 122VU
1WE
2WE
3WE
4WE

ENG FIRE/EXTING
L BTL SQUIBS
ENG FIRE/EXTING
R BTL/SQUIBS
ENG FIRE/EXTING
L BTL SQUIBS
ENG FIRE/EXTING
R BTL SQUIBS

CTL & IND/HOT SPLY/


CTL & IND/HOT SPLY/
CTL & IND/EMER SPLY/
CTL & IND/EMER SPLY/

*** CONTINUED ***


AH

30-11-61
OPT 10000-007
2-400 PAGE
2
DEC 01/14

30-11-61

OPERATIONAL TEST OF REGU


LATOR AND SHUT OFF VALVE
BY USING ENG FIRE HANDLE

004

OPT 10000-007
3

DEC14

___________________________________
OPENING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000

005

ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


___________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

006

_________________________________
READING
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RDG-10000

007

_________________________________
ERASURE
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RON-10000
NOTE:THIS TASK MUST BE PERFORMED ONLY IF FAULTS
RELATIVE TO THE SYSTEM TO BE CHECKED HAVE
BEEN RECORDED BY THE MFC MAINTENANCE
MEMORY.

008

OPERATIONAL TEST OF ENGINE ANTI ICING PRESSURE


______________________________________________
REGULATOR AND SHUTOFF VALVES AND ENGINE ANTI
____________________________________________
ICING SHUT OFF VALVES WITH ENGINE FIRE HANDLES
______________________________________________
REF. FIG. 301100-OPT-00100
301100-OPT-00110.
NOTE : FOLLOWING TEST IS AN OPERATIONAL TEST OF
PRESSURE REGULATOR AND SHUT-OFF VALVE
AND SHUT-OFF VALVE OF LEFT ENGINE.
1. TO PERFORM TEST, CONNECT GROUND AIR PRESSURIZATION UNIT 4 BARS (58 PSI) (60L/SEC)
TO LEFT REGULATOR VALVE TEST PORT 1.
*** CONTINUED ***
AH

30-11-61
OPT 10000-007
2-400 PAGE
3
DEC 01/14

OPERATIONAL TEST OF REGU


LATOR AND SHUT OFF VALVE
BY USING ENG FIRE HANDLE

30-11-61

OPT 10000-007
4

DEC14

2. ON PANEL 702VU,
PLACE SWITCH WEIGHT ON WHEELS IN FLT
POSITION.
3. ON PANEL 24VU,
A. CHECK THAT AFR AIR BLEED PUSHBUTTON
SWITCH (2) IS PRESSED (IN) :
- FAULT LEGEND OFF,
- OFF LEGEND OFF.
B. PRESS ENG1 AND ENG2 PUSHBUTTON
SWITCHES (6) AND (7) :
- FAULT LEGEND OFF,
- ON LEGEND ON.
ON MFD, IN TEMPORARY SELECTION WINDOW,
CYAN 1 ENG 2 MESSAGE IS DISPLAYED.
C. PRESS AIRFRAME PUSHBUTTON SWITCH (3)
- FAULT LEGEND OFF,
- ON LEGEND ON.
ON MFD, IN TEMPORARY SELECTION WINDOW,
CYAN AIRFRAME MESSAGE IS DISPLAYED.
4. DURING 3 OR 4 MINUTES, ALLOW CYCLE TO RUN.
- NO WARNING MUST APPEAR,
- CHECK VISUALLY THAT WING AND ENGINES
DE ICERS INFLATE.
5. LIFT MECHANICAL LOCKING SYSTEM OF ENG1
FIRE HANDLE.
PULL FIRE HANDLE.
6. ON PANEL 24VU,
ON AFR AIR BLEED PUSHBUTTON SWITCH (2) :
- FAULT LEGEND ON (AFTER 6S),
- OFF LEGEND OFF.
7. FOLLOWINGS WARNINGS APPEAR :
- ON EWD, IN ALERT WINDOW, A-ICING BLEED
MESSAGE IS DISPLAYED.
*** CONTINUED ***
AH

30-11-61
OPT 10000-007
2-400 PAGE
4
DEC 01/14

OPERATIONAL TEST OF REGU


LATOR AND SHUT OFF VALVE
BY USING ENG FIRE HANDLE

30-11-61

OPT 10000-007
5

DEC14

- MASTER CAUTION ANNUNCIATORS COME ON.


- SINGLE CHIME SOUNDS.
NOTE: SINGLE CHINE AND CAUTION LIGHTS
ARE INHIBITED IF C.L.A}S (CONDITION
LEVER ANGLE) ARE IN FTR (FEATHER)
POSITION.
8. ON PANEL 24VU,
ON ENG1 AND ENG2 PUSHBUTTON SWITCHES
(6) AND (7) :
- FAULT LEGEND LIGHT ILLUMINATED DURING
2,5S EVERY 60S WHEN MODE SEL SAT LESS
THEN -18 CELSIUS DEGREES (1) PUSHBUTTON
SWITCH IS DEPRESSED AND EVERY 240S WHEN
MODE SELSAT LESS THEN -18 CELSIUS DEGREES
(1) PUSHBUTTON SWITCH IS PRESSED.
- ON LEGEND IS ON.
ON MFD, IN TEMPORARY SELECTION WINDOW, THE
SAME LOGIC IS APPLICATED WITH AMBER
1 ENG 2 MESSAGE.
9.CHECK VISUALLY THAT WING AND ENGINES DEICERS DO NOT INFLATE.
10.A.ON PANEL 24VU, RELEASE AFR AIR BLEED
PUSHBUTTON SWITCH (2) :
- FAULT LEGEND OFF,
- OFF LEGEND ON.
B. ON PANEL 24VU, AIRFRAME (3), ENG1 (6)
AND ENG2 (7) PUSHBUTTON SWITCHES
- FAULT LEGEND ON,
- ON LEGEND ON.
C. ON MFD, IN TEMPORARY SELECTION WINDOW,
AMBER 1 ENG 2 AND AIRFRAME MESSAGES
ARE DISPLAYED.
11.WARNINS REMAINS ON.
12.A.ON PANEL 24VU,
*** CONTINUED ***
AH

30-11-61
OPT 10000-007
2-400 PAGE
5
DEC 01/14

30-11-61

OPERATIONAL TEST OF REGU


LATOR AND SHUT OFF VALVE
BY USING ENG FIRE HANDLE

OPT 10000-007
6

DEC14

PRESS AFR AIR BLEED PUSHBUTTON


SWITCH (2) :
- FAULT LEGEND ON,
- OFF LEGEND OFF.
B. RESET AIFRAME PUSHBUTTON SWITCH (3)
(OFF/ON) :
- FAULT LEGEND OFF,
- ON LEGEND ON.
ON MFD, IN TEMPORARY SELECTION WINDOW,
CYAN AIRFRAME MESSAGE IS DISPLAYED.
C. RESET ENG1 AND ENG2 PUSHBUTTON
SWITCHES (6) AND (7) (OFF/ON):
- FAULT LEGEND LIGHT IS ILLUMINATED
DURING 2,5S EVERY 60S WHEN PUSHBUTTON
SWITCH (1) IS DEPRESSED AND 240S WHEN
THE PUSHBUTTON SWITCH (1) IS PRESSED.
- ON LEGEND IS ON.
ON MFD, IN TEMPORARY SELECTION WINDOW,
THE SAME LOGIC IS APPLICATED WITH AMBER
1 ENG 2 MESSAGE.
13.PUSH ENG1 FIRE HANDLE, LOWER MECHANICAL
LOCKING SYSTEM.
- ALL WARNING DISAPPEAR.
14.A.ON PANEL 24VU :
RELEASE AIRFRAME (3), ENG1 (6) AND
ENG2 (7) PUSHBUTTON SWITCHES
- FAULT LEGEND OFF,
- ON LEGEND OFF.
B.ON MFD, IN TEMPORARY SELECTION WINDOW,
1 ENG 2 AND AIRFRAME MESSAGES
DISAPPEAR.
15 ON PANEL 702VU,
PLACE SWITCH WEIGHT ON WHEELS IN NORM
POSITION.
*** CONTINUED ***
AH

30-11-61
OPT 10000-007
2-400 PAGE
6
DEC 01/14

30-11-61

OPERATIONAL TEST OF REGU


LATOR AND SHUT OFF VALVE
BY USING ENG FIRE HANDLE

OPT 10000-007
7

DEC14

16.DISCONNECT GROUND AIR PRESSURIZATION UNIT.


NOTE : FOR OPERATIONAL TEST OF PRESSURE
REGULATOR AND SHUT-OFFVALVES OF RIGHT
ENGINE, REPEAT TEST ABOVE USING
ENG2 FIRE HANDLE.
009

_________________________________
READING
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RDG-10000

010

_________________________________
ERASURE
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RON-10000

011

DE-ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


______________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

012

________
CLOSE-UP
1. INSTALL BREAK WIRE ON MECHANICAL LOCKING
SYSTEM ON ENG1 AND ENG2 FIRE HANDLES
AND PLACE THE GARANTEE SEALING.
2. ON PANEL 122VU, REMOVE SAFETY TAGS AND
CLOSE THE CIRCUIT BREAKERS PREVIOUSLY
OPENED.
3. MAKE CERTAIN THAT WORKING AREA IS CLEAN
AND CLEAR OF TOOLS AND MISCELLANEOUS ITEMS
OF EQUIPMENT.
4. REMOVE PLATFORM AFTER CLOSING ENGINE COWLS
435AL (445AL).

*** CONTINUED ***


AH

30-11-61
OPT 10000-007
2-400 PAGE
7
DEC 01/14

30-11-61

OPERATIONAL TEST OF REGU


LATOR AND SHUT OFF VALVE
BY USING ENG FIRE HANDLE

013

OPT 10000-007
8

DEC14

___________________________________
CLOSING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000
*****

AH

E N D

O F

T E X T

*****

30-11-61
OPT 10000-007
2-400 PAGE
8
DEC 01/14

30-11-61
9

AH

CONTROLS AND INDICATING


WING/ENGINE DE ICING

OPT 10000-007
DEC14

30-11-61
OPT 10000-007

2-400

PAGE
9
DEC 01/14

30-11-61
10

AH

TEST COUPLING - PRESSURE


REGULATOR AND SHUT-OFF
VALVE

OPT 10000-007
DEC14

30-11-61
OPT 10000-007

2-400

PAGE
10
DEC 01/14

30-11-61

OPERATIONAL TEST OF
PRESSURE AND REGULATING
SHUT OFF VALVE

OPT 10010-004
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 210
435
445
: 435AL 445AL

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

GSE

: 01 ACCESS PLATFORM

_________
MAN-HOURS

PUBLICATION
___________
JIC
JIC
JIC
JIC

: OPENING AND CLOSING OF


HINGED ENGINE COWLS
: DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY
: READING OF MFC
MAINTENANCE MEMORY
: ERASURE OF MFC
MAINTENANCE MEMORY

AH

54-00-00-OAC-10000
24-46-00-EAD-10000
45-13-00-RDG-10000
45-13-00-RON-10000

30-11-61
OPT 10010-004
2-400 PAGE
1
DEC 01/14

OPERATIONAL TEST OF
PRESSURE AND REGULATING
SHUT OFF VALVE

001

30-11-61

OPT 10010-004
2

DEC14

___________
PREPARATION
1. INSTALL PLATFORM TO GAIN ACCES TO PRESSURE
REGULATOR AND SHUT OFF VALVE (PRSOV)
13DM (14DM).

002

OPENING OF LEFT LATERAL


_______________________
HINGED COWLS
____________
SEE JOB INSTRUCTION CARD
540000-OAC-10000

003

ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


___________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

004

______________________
CHECK
OF MFC OPERATION
1. ON PANEL 25VU, CHECK THAT THE FOLLOWING
PUSHBUTTON SWITCHES ARE PRESSED
(OFF LEGENDS ARE OFF):
6UA1
6UA2
7UA1
7UA2

005

MFC/1B/FAULT/OFF
MFC/2B/FAULT/OFF
MFC/1A/FAULT/OFF
MFC/2A/FAULT/OFF

OPERATIONAL TEST OF PRESSURE AND REGULATING


___________________________________________
SHUT OFF VALVE
______________
REF. FIG. 301100-OPT-00100
1. RUN ENGINE 1 AND 2.
2. ON PANEL 702VU,
PLACE SWITCH WEIGHT ON WHEELS IN FLT
POSITION.
3. ON PANEL 24VU,
*** CONTINUED ***
AH

30-11-61
OPT 10010-004
2-400 PAGE
2
DEC 01/14

30-11-61

OPERATIONAL TEST OF
PRESSURE AND REGULATING
SHUT OFF VALVE

OPT 10010-004
3

DEC14

A. CHECK THAT (7DM) AIRFRAME PUSHBUTTON


SWITCH (3) IS RELEASED :
-FAULT LEGEND OFF,
-ON LEGEND OFF.
B. RELEASE (20DM) AFR AIR BLEED PUSHBUTTON
SWITCH (2) :
-FAULT LEGEND OFF,
-OFF LEGEND ON.
C. PRESS (1DN) ENG 1 AND (2DN) ENG 2
PUSHBUTTON SWITCHES (6) AND (7) :
-FAULT LEGEND OFF,
-ON LEGEND ON.
4. WAIT 3MN, AND VERIFY THAT WHEN THE ENGINES
BOOTS ARE INFLATED, NO WARNINGS APPEARS.
5. ON PANEL 24VU,
A. RELEASE (1DN) ENG 1 AND (2DN) ENG 2
PUSHBUTTON SWITCHES (6) AND (7) :
-FAULT LEGEND OFF,
-ON LEGEND OFF.
B. PRESS (20DM) AFR AIR BLEED PUSHBUTTON
SWITCH (2):
-FAULT LEGEND OFF,
-OFF LEGEND OFF.
6. ON PANEL 702VU,
PLACE SWITCH WEIGHT ON WHEELS IN NORM
POSITION.
7. SHUT DOWN THE ENGINE 1 AND 2.
006

_________________________________
READING
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RDG-10000

007

_________________________________
ERASURE
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RON-10000
*** CONTINUED ***
AH

30-11-61
OPT 10010-004
2-400 PAGE
3
DEC 01/14

30-11-61

OPERATIONAL TEST OF
PRESSURE AND REGULATING
SHUT OFF VALVE

OPT 10010-004
4

DEC14

NOTE:THIS TASK MUST BE PERFORMED ONLY IF FAULTS


RELATIVE TO THE SYSTEM TO BE CHECKED HAVE
BEEN RECORDED BY THE MFC MAINTENANCE
MEMORY.
008

DE-ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


______________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

009

CLOSING OF LEFT LATERAL


_______________________
HINGED COWLS
____________
SEE JOB INSTRUCTION CARD
540000-OAC-10000
*****

AH

E N D

O F

T E X T

*****

30-11-61
OPT 10010-004
2-400 PAGE
4
DEC 01/14

30-11-61
5

AH

CONTROLS AND INDICATING


WING/ENGINE DE ICING

OPT 10010-004
DEC14

30-11-61
OPT 10010-004

2-400

PAGE
5
DEC 01/14

30-11-61
6

AH

TEST COUPLING - PRESSURE


REGULATOR AND SHUT-OFF
VALVE

OPT 10010-004
DEC14

30-11-61
OPT 10010-004

2-400

PAGE
6
DEC 01/14

30-11-61

OPERATIONAL TEST OF
PRESSURE AND REGULATING
SHUT OFF VALVE

OPT 10010-005
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 210
435
445
: 435AL 445AL

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

GSE

: 01 ACCESS PLATFORM

_________
MAN-HOURS

PUBLICATION
___________
JIC
JIC
JIC
JIC

: OPENING AND CLOSING OF


HINGED ENGINE COWLS
: DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY
: READING OF MFC
MAINTENANCE MEMORY
: ERASURE OF MFC
MAINTENANCE MEMORY

AH

54-00-00-OAC-10000
24-46-00-EAD-10000
45-13-00-RDG-10000
45-13-00-RON-10000

30-11-61
OPT 10010-005
2-400 PAGE
1
DEC 01/14

30-11-61

OPERATIONAL TEST OF
PRESSURE AND REGULATING
SHUT OFF VALVE

001

OPT 10010-005
2

DEC14

___________
PREPARATION
1. INSTALL PLATFORM TO GAIN ACCES TO PRESSURE
REGULATOR AND SHUT OFF VALVE (PRSOV)
13DM (14DM).

002

OPENING OF LEFT LATERAL


_______________________
HINGED COWLS
____________
SEE JOB INSTRUCTION CARD
540000-OAC-10000

003

ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


___________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

004

______________________
CHECK
OF MFC OPERATION
1. ON PANEL 25VU, CHECK THAT THE FOLLOWING
PUSHBUTTON SWITCHES ARE PRESSED
(OFF LEGENDS ARE OFF):
6UA1
6UA2
7UA1
7UA2

005

MFC/1B/FAULT/OFF
MFC/2B/FAULT/OFF
MFC/1A/FAULT/OFF
MFC/2A/FAULT/OFF

OPERATIONAL TEST OF FIRST LEVEL PRESSURE


________________________________________
REGULATION OF THE PRSOV VALVE
_____________________________
REF. FIG. 301100-OPT-00100
REF. FIG. 301100-OPT-00110
1. CONNECT MANOMETER TO TEST PORT 3.
2. CONNECT THE COMPRESSOR TO PRSOV TEST PORT 1
AND SET THE SUPPLIED PRESSURE TO 4 BAR.
3. ON PANEL 24VU, CHECK THAT (20DM) AFR AIR
*** CONTINUED ***
AH

30-11-61
OPT 10010-005
2-400 PAGE
2
DEC 01/14

30-11-61

OPERATIONAL TEST OF
PRESSURE AND REGULATING
SHUT OFF VALVE

OPT 10010-005
3

DEC14

BLEED PUSHBUTTON SWITCH (2) IS PRESSED:


-FAULT LEGEND IS OFF,:
-OFF LEGEND GOES OFF.
4. CHECK THAT THE PRESSURE READ BY THEUSHBUTTON
MANOMETER IS 1.4
0.05 BAR
(20.30
0.72 PSI)
5. ON PANEL 24VU:
A. PRESS (1DN) ENG 1 AND (2DN) ENG 2
PUSHBUTTON SWITCHES (6) AND (7):
-FAULT LEGEND IS OFF,
-ON LEGEND GOES ON.
B. PRESS (7DM) AIRFRAME PUSHBUTTON
SWITCH (3):
-FAULT LEGEND IS OFF,
-ON LEGEND GOES ON.
6. ON PANEL 402VU, CHECK THAT (12DM) DE ICING
ANNUNCIATOR LIGHT (4) IS ON.
7. WAIT 3MN, NO WARNINGS MUST APPEAR. CHECK
VISUALLY THE DE-ICERS INFLATION.
8. ON PANEL 24VU:
A. RELEASE (7DM) AIRFRAME PUSHBUTTON
SWITCH (3):
-FAULT LEGEND IS OFF,
-ON LEGEND GOES OFF.
B. RELEASE (1DN) ENG 1 AND (2DN) ENG 2
PUSHBUTTON SWITCHES (6) AND (7):
-FAULT LEGEND IS OFF,
-OFF LEGEND GOES OFF.
9. ON PANEL 402VU,CHECK THAT (12DM) DE ICING
ANNUNCIATOR (4) IS OFF.
10. DISCONNECT THE COMPRESSOR FROM TEST PORT 1.
11. INSTALL PROTECTIVE PLUG ON VALVE TEST
PORT 1.
*** CONTINUED ***
AH

30-11-61
OPT 10010-005
2-400 PAGE
3
DEC 01/14

30-11-61

OPERATIONAL TEST OF
PRESSURE AND REGULATING
SHUT OFF VALVE

006

OPT 10010-005
4

DEC14

OPERATIONAL TEST OF SECOND LEVEL


________________________________
PRESSURE REGULATION OF THE PRSOV VALVE
______________________________________
REF. FIG. 301100-OPT-00100
REF. FIG. 301100-OPT-00110.
1. CONNECT THE COMPRESSOR TO PRSOV TEST PORT 2
AND SET THE SUPPLIED PRESSURE TO 4 BAR.
2. ON PANEL 24VU, CHECK THAT (20DM) AFR AIR
BLEED PUSHBUTTON SWITCH (2) IS PRESSED:
- FAULT LEGEND IS OFF,
- OFF LEGEND GOES OFF.
3. CHECK THAT THE PRESSURE READ BY THE
MANOMETER IS LESS THAN 1.65 BAR
(23.92 PSI).
4. ON PANEL 24VU:
A. PRESS (1DN) ENG 1 AND (2DN) ENG 2
PUSHBUTTON SWITCHES (6) AND (7):
- FAULT LEGEND IS OFF,
- ON LEGEND GOES ON.
B. PRESS (7DM) AIRFRAME PUSHBUTTON
SWITCH (3):
- FAULT LEGEND IS OFF,
- ON LEGEND GOES ON.
5. ON PANEL 402VU, CHECK THAT (12DM)
DE ICING ANNUNCIATOR LIGHT (4) IS ON.
6. WAIT 3MN, NO WARNINGS MUST APPEAR.
CHECK VISUALLY THE DE-ICERS INFLATION.
7. ON PANEL 24VU:
A. RELEASE (7DM) AIRFRAME PUSHBUTTON
SWITCH (3):
- FAULT LEGEND IS OFF,
- ON LEGEND GOES OFF.
B. RELEASE (1DN) ENG 1 AND (2DN) ENG 2
PUSHBUTTON SWITCHES (6) AND (7):
*** CONTINUED ***
AH

30-11-61
OPT 10010-005
2-400 PAGE
4
DEC 01/14

30-11-61

OPERATIONAL TEST OF
PRESSURE AND REGULATING
SHUT OFF VALVE

OPT 10010-005
5

DEC14

- FAULT LEGEND IS OFF,


- ON LEGEND GOES OFF.
8. ON PANEL 402VU, CHECK THAT (12DM)
DE ICING ANNUNCIATOR (4) IS OFF.
9. DISCONNECT GROUND AIR PRESSURIZATION UNIT
10.INSTALL PROTECTIVE PLUG ON REGULATOR
VALVE TEST PORT 2.
11.DISCONNECT MANOMETER FROM PRSOV VALVE.
12.INSTALL PROTECTIVE PLUG ON TEST PORT 3.
NOTE: USING THE PROCEDURE BELOW MAKE SURE
THAT THE FOLLOWING FAILURES ARE NOT
MEMORIZED IN THE MFC MAINTENANCE
MEMORY NAVIGATION MEMORY:
LH (RH) PRSOV NORMAL PRESS FAULT.
007

_________________________________
READING
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RDG-10000

008

_________________________________
ERASURE
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RON-10000
NOTE:THIS TASK MUST BE PERFORMED ONLY IF FAULTS
RELATIVE TO THE SYSTEM TO BE CHECKED HAVE
BEEN RECORDED BY THE MFC MAINTENANCE
MEMORY.

009

DE-ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


______________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000
*** CONTINUED ***
AH

30-11-61
OPT 10010-005
2-400 PAGE
5
DEC 01/14

30-11-61

OPERATIONAL TEST OF
PRESSURE AND REGULATING
SHUT OFF VALVE

010

OPT 10010-005
6

DEC14

________
CLOSE-UP
1. CHECK THAT WORKING AREA IS CLEAN AND CLEAR
OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
2. REMOVE ACCESS PLATFORM AFTER CLOSING ENGINE
COWLS 435AL (445AL) AS FOLLOWS.

011

CLOSING OF LEFT LATERAL


_______________________
HINGED COWLS
____________
SEE JOB INSTRUCTION CARD
540000-OAC-10000
*****

AH

E N D

O F

T E X T

*****

30-11-61
OPT 10010-005
2-400 PAGE
6
DEC 01/14

30-11-61
7

AH

CONTROLS AND INDICATING


WING/ENGINE DE ICING

OPT 10010-005
DEC14

30-11-61
OPT 10010-005

2-400

PAGE
7
DEC 01/14

30-11-61
8

AH

TEST COUPLING - PRESSURE


REGULATOR AND SHUT-OFF
VALVE

OPT 10010-005
DEC14

30-11-61
OPT 10010-005

2-400

PAGE
8
DEC 01/14

30-11-61

OPERATIONAL TEST OF
PRESSURE AND REGULATING
SHUT OFF VALVE

OPT 10010-006
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 210
435
445
: 435AL 445AL

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

GSE

: 01 ACCESS PLATFORM

_________
MAN-HOURS

PUBLICATION
___________
JIC
JIC
JIC
JIC
JIC

: PRINCIPLE OF CDS USE


(DISPLAY UNITS
EXPLORATION)
: OPENING AND CLOSING OF
HINGED ENGINE COWLS
: DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY
: READING OF MFC
MAINTENANCE MEMORY
: ERASURE OF MFC
MAINTENANCE MEMORY

AH

31-63-00-PRO-10000
54-00-00-OAC-10000
24-46-00-EAD-10000
45-13-00-RDG-10000
45-13-00-RON-10000

30-11-61
OPT 10010-006
2-400 PAGE
1
DEC 01/14

30-11-61

OPERATIONAL TEST OF
PRESSURE AND REGULATING
SHUT OFF VALVE

001

OPT 10010-006
2

DEC14

PRINCIPLE OF CDS USE (DISPLAY UNITS


___________________________________
EXPLORATION)
____________
(TO USE ONLY IF NEEDED)
_______________________
SEE JOB INSTRUCTION CARD
316300-PRO-10000
NOTE: PROCEDURE TO USE ONLY IF NEEDED.
THIS PROCEDURE DESCRIBES LOCATION AND
MANAGEMENT OF THE DIFFERENT DISPLAY
WINDOWS PROVIDED BY THE THREE FORMATS
(PFD, EWD, MFD) PROPOSED ON THE FIVE
DISPLAY UNITS (DU).

002

___________
PREPARATION
1. INSTALL PLATFORM TO GAIN ACCES TO PRESSURE
REGULATOR AND SHUT OFF VALVE (PRSOV)
13DM (14DM).

003

OPENING OF LEFT LATERAL


_______________________
HINGED COWLS
____________
SEE JOB INSTRUCTION CARD
540000-OAC-10000

004

ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


___________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

005

______________________
CHECK
OF MFC OPERATION
1. ON PANEL 25VU, CHECK THAT THE FOLLOWING
PUSHBUTTON SWITCHES ARE PRESSED
(OFF LEGENDS ARE OFF):
6UA1
6UA2
7UA1

MFC/1B/FAULT/OFF
MFC/2B/FAULT/OFF
MFC/1A/FAULT/OFF
*** CONTINUED ***

AH

30-11-61
OPT 10010-006
2-400 PAGE
2
DEC 01/14

30-11-61

OPERATIONAL TEST OF
PRESSURE AND REGULATING
SHUT OFF VALVE

7UA2
006

OPT 10010-006
3

DEC14

MFC/2A/FAULT/OFF

OPERATIONAL TEST OF FIRST LEVEL PRESSURE


________________________________________
REGULATION OF THE PRSOV VALVE
_____________________________
REF. FIG. 301100-OPT-00100
REF. FIG. 301100-OPT-00110
1. CONNECT MANOMETER TO TEST PORT 3.
2. CONNECT THE COMPRESSOR TO PRSOV TEST PORT 1
AND SET THE SUPPLIED PRESSURE TO 4 BAR.
3. ON PANEL 24VU, CHECK THAT (20DM) AFR AIR
BLEED PUSHBUTTON SWITCH (2) IS PRESSED:
-FAULT LEGEND IS OFF,
-OFF LEGEND GOES OFF.
4. CHECK THAT THE PRESSURE READ BY THE
MANOMETER IS 1.4
0.05 BAR
(20.30
0.72 PSI)
5. ON PANEL 24VU:
A. PRESS (1DN) ENG 1 AND (2DN) ENG 2
PUSHBUTTON SWITCHES (6) AND (7):
-FAULT LEGEND IS OFF,
-ON LEGEND GOES ON.
-ON MFD, IN TEMPORARY SELECTION WINDOW,
NO AIRFRAME MESSAGE IS DISPLAYED.
B. PRESS (7DM) AIRFRAME PUSHBUTTON
SWITCH (3):
-FAULT LEGEND IS OFF,
-ON LEGEND GOES ON.
-ON MFD, IN TEMPORARY SELECTION WINDOW,
NO AIRFRAME MESSAGE IS DISPLAYED
6. ON PANEL 402VU, CHECK THAT (12DM) DE ICING
ANNUNCIATOR LIGHT (4) IS ON.
7. WAIT 3MN, NO WARNINGS MUST APPEAR. CHECK
VISUALLY THE DE-ICERS INFLATION.
*** CONTINUED ***
AH

30-11-61
OPT 10010-006
2-400 PAGE
3
DEC 01/14

30-11-61

OPERATIONAL TEST OF
PRESSURE AND REGULATING
SHUT OFF VALVE

OPT 10010-006
4

DEC14

8. ON PANEL 24VU:
A. RELEASE (7DM) AIRFRAME PUSHBUTTON
SWITCH (3):
-FAULT LEGEND IS OFF,
-ON LEGEND GOES OFF.
B. RELEASE (1DN) ENG 1 AND (2DN) ENG 2
PUSHBUTTON SWITCHES (6) AND (7):
-FAULT LEGEND IS OFF,
-OFF LEGEND GOES OFF.
-ON MFD, IN TEMPORARY SELECTION WINDOW,
1 ENG 2 MESSAGE DISAPPEARS.
9. ON PANEL 402VU,CHECK THAT (12DM) DE ICING
ANNUNCIATOR (4) IS OFF.
10.DISCONNECT THE COMPRESSOR FROM TEST PORT 1.
11.INSTALL PROTECTIVE PLUG ON VALVE TEST
PORT 1.
007

OPERATIONAL TEST OF SECOND LEVEL


________________________________
PRESSURE REGULATION OF THE PRSOV VALVE
______________________________________
REF. FIG. 301100-OPT-00100
REF. FIG. 301100-OPT-00110.
1. CONNECT THE COMPRESSOR TO PRSOV TEST PORT 2
AND SET THE SUPPLIED PRESSURE TO 4 BAR.
2. ON PANEL 24VU, CHECK THAT (20DM) AFR AIR
BLEED PUSHBUTTON SWITCH (2) IS PRESSED:
- FAULT LEGEND IS OFF,
- OFF LEGEND GOES OFF.
3. CHECK THAT THE PRESSURE READ BY THE
MANOMETER IS LESS THAN 1.65 BAR
(23.92 PSI).
4. ON PANEL 24VU:
A. PRESS (1DN) ENG 1 AND (2DN) ENG 2
PUSHBUTTON SWITCHES (6) AND (7):
*** CONTINUED ***
AH

30-11-61
OPT 10010-006
2-400 PAGE
4
DEC 01/14

30-11-61

OPERATIONAL TEST OF
PRESSURE AND REGULATING
SHUT OFF VALVE

OPT 10010-006
5

DEC14

- FAULT LEGEND IS OFF,


- ON LEGEND GOES ON.
- ON MFD, IN TEMPORARY SELECTION WINDOW,
NO AIRFRAME MESSAGE IS DISPLAYED.
B. PRESS (7DM) AIRFRAME PUSHBUTTON
SWITCH (3):
- FAULT LEGEND IS OFF,
- ON LEGEND GOES ON.
- ON MFD, IN TEMPORARY SELECTION WINDOW,
NO AIRFRAME MESSAGE IS DISPLAYED.
5. ON PANEL 402VU, CHECK THAT (12DM)
DE-ICING ANNUNCIATOR LIGHT (4) IS ON.
6. WAIT 3MN, NO WARNINGS MUST APPEAR.
CHECK VISUALLY THE DE-ICERS INFLATION.
7. ON PANEL 24VU:
A. RELEASE (7DM) AIRFRAME PUSHBUTTON
SWITCH (3):
- FAULT LEGEND IS OFF,
- ON LEGEND GOES OFF.
B. RELEASE (1DN) ENG 1 AND (2DN) ENG 2
PUSHBUTTON SWITCHES (6) AND (7):
- FAULT LEGEND IS OFF,
- ON LEGEND GOES OFF.
- ON MFD, IN TEMPORARY SELECTION WINDOW,
1 ENG 2 MESSAGE DISAPPEARS.
8. ON PANEL 402VU, CHECK THAT (12DM)
DE-ICING ANNUNCIATOR (4) IS OFF.
9. DISCONNECT GROUND AIR PRESSURIZATION UNIT
10.INSTALL PROTECTIVE PLUG ON REGULATOR
VALVE TEST PORT 2.
11.DISCONNECT MANOMETER FROM PRSOV VALVE.
12.INSTALL PROTECTIVE PLUG ON TEST PORT 3.
*** CONTINUED ***
AH

30-11-61
OPT 10010-006
2-400 PAGE
5
DEC 01/14

30-11-61

OPERATIONAL TEST OF
PRESSURE AND REGULATING
SHUT OFF VALVE

OPT 10010-006
6

DEC14

NOTE: USING THE PROCEDURE BELOW MAKE SURE


THAT THE FOLLOWING FAILURES ARE NOT
MEMORIZED IN THE MFC MAINTENANCE
MEMORY NAVIGATION MEMORY:
LH (RH) PRSOV NORMAL PRESS FAULT.
008

_________________________________
READING
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RDG-10000

009

_________________________________
ERASURE
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RON-10000
NOTE:THIS TASK MUST BE PERFORMED ONLY IF FAULTS
RELATIVE TO THE SYSTEM TO BE CHECKED HAVE
BEEN RECORDED BY THE MFC MAINTENANCE
MEMORY.

010

DE-ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


______________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

011

________
CLOSE-UP
1. CHECK THAT WORKING AREA IS CLEAN AND CLEAR
OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
2. REMOVE ACCESS PLATFORM AFTER CLOSING ENGINE
COWLS 435AL (445AL) AS FOLLOWS.

012

CLOSING OF LEFT LATERAL


_______________________
HINGED COWLS
____________
SEE JOB INSTRUCTION CARD
540000-OAC-10000
*****
AH

E N D

O F

T E X T

*****

30-11-61
OPT 10010-006
2-400 PAGE
6
DEC 01/14

30-11-61
7

AH

CONTROLS AND INDICATING


WING/ENGINE DE ICING

OPT 10010-006
DEC14

30-11-61
OPT 10010-006

2-400

PAGE
7
DEC 01/14

30-11-61
8

AH

TEST COUPLING - PRESSURE


REGULATOR AND SHUT-OFF
VALVE

OPT 10010-006
DEC14

30-11-61
OPT 10010-006

2-400

PAGE
8
DEC 01/14

30-11-61

REMOVAL/INSTALLATION OF
PRESSURE REGULATOR AND
SHUT OFF VALVE

RAI 10000-001
1

MAR12

ZONING DATA
___________
ZONE
ACCESS

: 435
445
:
T
435AL 445AL

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

GSE

: 01 ACCESS PLATFORM

SPARE

: 02 REGULATOR & SHUTOFF VALVE

301160-10-080

EXPENDABLE

: 02
02
02
02

301160-10-040
301160-10-070
301160-10-050
301160-10-030

O-RING
O-RING
UNION
UNION

BULK MATERIAL : GREASE

_________
MAN-HOURS

04-020

PUBLICATION
___________
JIC
JIC

: OPENING AND CLOSING OF


HINGED ENGINE COWLS
: OPERATIONAL TEST OF AIR
FOIL DE-ICING SYSTEM

AH

54-00-00-OAC-10000
30-11-00-OPT-10000

30-11-61
RAI 10000-001
2-400 PAGE
1
MAR 01/12

30-11-61

REMOVAL/INSTALLATION OF
PRESSURE REGULATOR AND
SHUT OFF VALVE

001

RAI 10000-001
2

MAR12

___________
PREPARATION
1. ON PANEL 122VU, OPEN SAFETY AND TAG THE
FOLLOWING CIRCUIT BREAKERS :
1DM
28DM

ANTI/DE ICING/AAS/BOOTS A & B IND


ANTI/DE ICING/SO & REG VALVES 1 & 2

2. INSTALL PLATFORM TO GAIN ACCESS TO VALVE


13DM (14DM).
3. OPEN ENGINE COWL 435AL (445AL).
002

___________________________________
OPENING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000

003

REMOVAL OF REGULATOR AND SHUTOFF


________________________________
VALVE.
______
REF. FIG. 301161-RAI-00100
1. DISCONNECT ELECTRICAL CONNECTOR (1) ON
REGULATION VALVE (2).
2. REMOVE DUCTS (4) AND (5).
3. DISCONNECT DUCT (3).
4. REMOVE BOLTS (11), NUTS (12) AND REGULATION
VALVE (2). DISCARD NUTS (12).
5. INSTALL BLANKING PLUGS ON DUCTS AND ELECTRICAL CONNECTOR.
6. LOOSEN NUT (6), REMOVE UNION (7) AND DISCARD
O-RING (8).
7. REMOVE UNION (9) AND DISCARD O-RING (10).
*** CONTINUED ***
AH

30-11-61
RAI 10000-001
2-400 PAGE
2
MAR 01/12

30-11-61

REMOVAL/INSTALLATION OF
PRESSURE REGULATOR AND
SHUT OFF VALVE

004

RAI 10000-001
3

MAR12

___________________________________________
INSTALLATION
OF REGULATOR AND SHUTOFF VALVE
REF. FIG. 301161-RAI-00100
1. INSTALL UNION (7) FITTED WITH ITS NUT (6)
AND ITS O-RING (8).
2. ADJUST UNION TO THEORETICAL DIMENSION OF
101.13 PLUS OR MINUS 1 TURN.
POSITION UNION AT 12429} WITH RESPECT TO
VERTICAL DIRECTION (CLOCKWISE).
3. DO NOT TIGHTEN NUT (6).
4. POSITION UNION (9) FITTED WITH ITS O-RING
(10). COAT UNION THREADED PARTS WITH GREASE
04-020. TIGHTEN UNION (TORQUE VALUE 4.8 TO
5.3 M.DAN/424.7 TO 469 LBF.IN).
5. CLEAN AND INSPECT EQUIPMENT INSTALLATION
AREA.
6. REMOVE THE BLANKING PLUGS.
7. POSITION REGULATION VALVE (2) (ARROW POINTED
TOWARDS REAR OF ENGINE), USING BOLTS (11)
AND NUTS (12).
8. CONNECT DUCT (3), TIGHTEN (TORQUE VALUE 12.9
TO 14.2 M.DAN/1141.5 TO 1256.6 LBF.IN).
9. INSTALL DUCTS (4) AND (5), TIGHTEN (TORQUE
VALUE 9.7 TO 10.7 M.DAN/858.4 TO
946.9 LBF.IN).
10. TIGHTEN NUT (6) (TORQUE VALUE 4.8 TO 5.3
M.DAN/424.7 TO 469 LBF.IN).
11. CONNECT ELECTRICAL CONNECTOR (1).

*** CONTINUED ***


AH

30-11-61
RAI 10000-001
2-400 PAGE
3
MAR 01/12

30-11-61

REMOVAL/INSTALLATION OF
PRESSURE REGULATOR AND
SHUT OFF VALVE

005

RAI 10000-001
4

MAR12

OPERATIONAL TEST OF AIR FOIL DE-ICING SYSTEM


____________________________________________
WITH EACH REGULATOR VALVE
_________________________
SEE JOB INSTRUCTION CARD
301100-OPT-10000

006

________
CLOSE-UP
1. CHECK THAT WORKING AREA IS CLEAN AND CLEAR
OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
2. CLOSE ENGINE COWL 435AL (445AL).
3. REMOVE ACCESS PLATFORM.
4. CLOSE CIRCUIT BREAKERS MENTIONED ABOVE.

007

___________________________________
CLOSING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000
*****

AH

E N D

O F

T E X T

*****

30-11-61
RAI 10000-001
2-400 PAGE
4
MAR 01/12

30-11-61
5

AH

REMOVAL AND INSTALLATION


0F RIGHT REGULATOR AND
SHUTOFF VALVE

RAI 10000-001
MAR12

30-11-61
RAI 10000-001

2-400

PAGE
5
MAR 01/12

30-11-61

REMOVAL/INSTALLATION OF
PRESSURE REGULATOR AND
SHUT OFF VALVE

RAI 10000-002
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 435
445
:
T
435AL 445AL

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

GSE

: 01 ACCESS PLATFORM

SPARE

: 02 REGULATOR & SHUTOFF VALVE

301160-10-080

EXPENDABLE

: 00
00
00

301160-10-050
301160-10-060
301160-10-070

BULK MATERIAL : GREASE

_________
MAN-HOURS

04-020

PUBLICATION
___________
JIC
JIC

: OPENING AND CLOSING OF


HINGED ENGINE COWLS
: OPERATIONAL TEST OF AIR
FOIL DE-ICING SYSTEM

AH

54-00-00-OAC-10000
30-11-00-OPT-10000

30-11-61
RAI 10000-002
2-400 PAGE
1
DEC 01/14

30-11-61

REMOVAL/INSTALLATION OF
PRESSURE REGULATOR AND
SHUT OFF VALVE

001

RAI 10000-002
2

DEC14

___________
PREPARATION
1. ON PANEL 122VU, OPEN SAFETY AND TAG THE
FOLLOWING CIRCUIT BREAKERS :
1DM
28DM

ANTI/DE ICING/AAS/BOOTS A & B IND


ANTI/DE ICING/SO & REG VALVES 1 & 2

2. INSTALL PLATFORM TO GAIN ACCESS TO VALVE


13DM (14DM).
3. OPEN ENGINE COWL 435AL (445AL).
002

___________________________________
OPENING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000

003

REMOVAL OF REGULATOR AND SHUTOFF


________________________________
VALVE
_____
REF. FIG. 301161-RAI-00100
1. DISCONNECT ELECTRICAL CONNECTOR (1) ON
REGULATION VALVE (2).
2. REMOVE DUCTS (4) AND (5).
3. DISCONNECT DUCT (3).
4. REMOVE BOLTS (9), NUTS (10) AND REGULATION
VALVE (2). DISCARD NUTS (10).
5. INSTALL BLANKING PLUGS ON DUCTS AND
ELECTRICAL CONNECTOR.
6. LOOSEN NUT (6),REMOVE UNION (7) AND DISCARD
O-RING (8).

*** CONTINUED ***


AH

30-11-61
RAI 10000-002
2-400 PAGE
2
DEC 01/14

30-11-61

REMOVAL/INSTALLATION OF
PRESSURE REGULATOR AND
SHUT OFF VALVE

004

RAI 10000-002
3

DEC14

___________________________________________
INSTALLATION
OF REGULATOR AND SHUTOFF VALVE
REF. FIG. 301161-RAI-00100
1. INSTALL UNION (7) FITTED WITH ITS NUT (6)
AND ITS O-RING (8).
2. ADJUST UNION TO THEORETICAL DIMENSION OF
101.13 PLUS OR MINUS 1 TURN.
POSITION UNION AT 12429} WITH RESPECT TO
VERTICAL DIRECTION (CLOCKWISE).
3. DO NOT TIGHTEN NUT (6).
4. REMOVE THE BLANKING PLUGS.
5. POSITION REGULATION VALVE (2) (ARROW POINTED
TOWARDS REAR OF ENGINE), USING BOLTS (9)
AND NUTS (10).
6. CONNECT DUCT (3), TIGHTEN (TORQUE VALUE 12.9
TO 14.2 M.DAN/1141.5 TO 1256.6 LBF.IN).
7. INSTALL DUCTS (4) AND (5), TIGHTEN (TORQUE
VALUE 9.7 TO 10.7 M.DAN/858.4 TO
946.9 LBF.IN).
8. TIGHTEN NUT (6) (TORQUE VALUE 4.8 TO 5.3
M.DAN/424.7 TO 469 LBF.IN).
9. CONNECT ELECTRICAL CONNECTOR (1).

005

OPERATIONAL TEST OF AIR FOIL DE-ICING SYSTEM


____________________________________________
WITH EACH REGULATOR VALVE
_________________________
SEE JOB INSTRUCTION CARD
301100-OPT-10000

*** CONTINUED ***


AH

30-11-61
RAI 10000-002
2-400 PAGE
3
DEC 01/14

30-11-61

REMOVAL/INSTALLATION OF
PRESSURE REGULATOR AND
SHUT OFF VALVE

006

RAI 10000-002
4

DEC14

________
CLOSE-UP
1. CHECK THAT WORKING AREA IS CLEAN AND CLEAR
OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
2. CLOSE ENGINE COWL 435AL (445AL).
3. REMOVE ACCESS PLATFORM.
4. CLOSE CIRCUIT BREAKERS MENTIONED ABOVE.

007

___________________________________
CLOSING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000
*****

AH

E N D

O F

T E X T

*****

30-11-61
RAI 10000-002
2-400 PAGE
4
DEC 01/14

30-11-61
5

AH

REMOVAL AND INSTALLATION


0F RIGHT REGULATOR AND
SHUTOFF VALVE

RAI 10000-002
DEC14

30-11-61
RAI 10000-002

2-400

PAGE
5
DEC 01/14

30-11-62

REMOVAL/INSTALLATION OF
SHUT OFF VALVES

RAI 10000-001
1

APR05

ZONING DATA
___________
ZONE
ACCESS

: 400
435
445
475
485
: 435AL 445AL 475AT 485AT

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

MECHANIC

_________
MAN-HOURS
02

ELAPSED TIME

GSE

: 01 ACCESS PLATFORM

SPARE

: 01 SHUTOFF VALVE (81DM)


01 SHUTOFF VALVE (82DM)

301160-08-220
301160-09-220

EXPENDABLE

: 01 O-RING
01 O-RING

301160-08-210
301160-09-210

BULK MATERIAL : SOLVENT(11-004B)


GREASE
GREASE (05-001A)
COMPOUND(08-004A)

11-004
04-020
05-001
08-004

PUBLICATION
___________
JIC
JIC

: OPENING AND CLOSING OF


HINGED ENGINE COWLS
: OPERATIONAL TEST OF REGU
LATOR AND SHUT-OFF VALVE
BY USING ENG FIRE HANDLE

AH

54-00-00-OAC-10000
30-11-61-OPT-10000

30-11-62
RAI 10000-001
2-400 PAGE
1
APR 01/05

30-11-62

REMOVAL/INSTALLATION OF
SHUT OFF VALVES

001

RAI 10000-001
2

APR05

___________
PREPARATION
1. ON PANEL 122VU, OPEN SAFETY AND TAG THE FOLLOWING CIRCUIT BREAKERS:
85DM

ANTI/DE ICING/ISOL VALVES 1 & 2

2. INSTALL PLATFORM TO GAIN ACCESS TO SHUTOFF


VALVE 81DM (82DM).
3. REMOVE ENGINE COWL 475AT (485AT).
4. OPEN ENGINE COWL 435AL (445AL).
002

_____________________________________________
REMOVAL
OF AFT UPPER ENGINE COWL 475AT(485AT)
REF. FIG. 540000-RAI-00130
1. REMOVE SCREWS (31) AND (32).
2. REMOVE COWL.
3. CLEAN THE MATING FACE WITH NON METALLIC TOOL
AND SOLVENT MAT. N11-004B

003

___________________________________
OPENING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000

004

________________________________
REMOVAL
OF ENGINE SHUTOFF VALVE.
REF. FIG. 301162-RAI-00100
1. DISCONNECT ELECTRICAL CONNECTOR (1) ON ISOLATION VALVE (5).
2. DISCONNECT SUPPLY LINE (3).
3. DISCONNECT DISTRIBUTION LINE (2).
*** CONTINUED ***
AH

30-11-62
RAI 10000-001
2-400 PAGE
2
APR 01/05

30-11-62

REMOVAL/INSTALLATION OF
SHUT OFF VALVES

RAI 10000-001
3

APR05

4. REMOVE NUT (4) AND ISOLATION VALVE ASSEMBLY.


5. LOOSEN NUT (6), REMOVE UNION (8) AND DISCARD
SEAL (9).
6. REMOVE UNION (7) AND DISCARD SEAL (10).
7. INSTALL BLANKING PLUG ON LINES (2), (3) AND
ELECTRICAL CONNECTOR (1).
005

_____________________________
INSTALLATION
OF SHUTOFF VALVE
REF. FIG. 301162-RAI-00100
1. INSTALL ELBOW UNION (8) FITTED WITH ITS NUT
(6) AND ITS SEAL (9).
COAT THREADED PARTS OF UNION WITH GREASE
04-020.
2. POSITION ELBOW UNION (8) 28 (39 02}) WITH
RESPECT TO ISOLATION VALVE (5) SOLENOID
CENTERLINE (CLOCKWISE).
TIGHTEN NUT (6) (TORQUE VALUE 4.8 TO 5.3
M.DAN/424.7 TO 469 LBF IN.).
3. POSITION UNION (7) FITTED WITH ITS SEAL
(10). COAT THREADED PARTS OF UNION WITH
GREASE 04-020. TIGHTEN UNION (7) (TORQUE
VALUE 4.8 TO 5.3 M.DAN/424.7 TO 469 LBF IN.)
4. CLEAN AND INSPECT EQUIPMENT INSTALLATION
AREA.
5. REMOVE BLANKING PLUGS.
6. INSTALL ISOLATION VALVE (5) (ARROW POINTED
TOWARDS REAR OF ENGINE). POSITION NUT (4)
WITHOUT TIGHTENING IT.
7. POSITION ISOLATION VALVE (5) SOLENOID CENTERLINE 15 WITH RESPECT TO HORIZONTAL AXIS
*** CONTINUED ***
AH

30-11-62
RAI 10000-001
2-400 PAGE
3
APR 01/05

30-11-62

REMOVAL/INSTALLATION OF
SHUT OFF VALVES

RAI 10000-001
4

APR05

(COUNTERCLOCKWISE).
8. TIGHTEN NUT (4) (TORQUE VALUE 9.7 TO 10.7
M.DAN/858.4 TO 946.9 LBF.IN).
9. CONNECT SUPPLY LINE (3), TIGHTEN (TORQUE
VALUE 9.7 TO 10.7 M.DAN/858.4 TO
946.9 LBF.IN).
10. CONNECT DISTRIBUTION LINE (2), TIGHTEN
(TORQUE VALUE 9.7 TO 10.7 M.DAN/858.4
TO 946.9 LBF.IN).
11. CONNECT ELECTRICAL CONNECTOR (1).
006

OPERATIONAL TEST OF REGULATOR AND SHUTOFF VALVE


_______________________________________________
BY USING ENGINE FIRE HANDLE
___________________________
SEE JOB INSTRUCTION CARD
301161-OPT-10000

007

________
CLOSE-UP
1. CHECK THAT WORKING AREA IS CLEAN AND CLEAR
OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
2. CLOSE ENGINE COWL 435AL (445AL).
3. INSTALL ENGINE COWL 475AT (485AT).
4. REMOVE ACCESS PLATFORM.
5. CLOSE CIRCUIT BREAKER MENTIONED ABOVE.

008

INSTALLATION OF AFT UPPER ENGINE COWL 475AT


___________________________________________
(485AT)
_______
REF. FIG. 540000-RAI-00130
1. CHECK FOR CORRECT CONDITION OF COWL.
*** CONTINUED ***
AH

30-11-62
RAI 10000-001
2-400 PAGE
4
APR 01/05

30-11-62

REMOVAL/INSTALLATION OF
SHUT OFF VALVES

RAI 10000-001
5

APR05

NOTE: - MAKE CERTAIN FOR PRESENCE OF WATER


REPELLENT PROTECTION ON COWLS 475AT
(485AT). IF NOT, MAKE THIS
PROTECTION (OR RESTORE IT) LIKE
PROCEDURE IN AMM 20-24-17.
- CHECK THAT BONDED CUPS INTO THE
COUNTERSUNK HOLES ARE NOT DAMAGED.
2. COAT UPPER PART OF CLIP SURFACE (33) WITH
MATERIAL NO. 05-001A (REF.20-31-00).
3. INSTALL COWL AND SECURE WITH SCREWS (31).
4. TIGHTEN SCREWS (32) (TIGHTENING TORQUE
CONTAINED BETWEEN 0.55 AND 0.65 M.DAN
(4.08 AND 4.8 FT.LBF)) MAKING CERTAIN THAT
CLEARANCE IN RELATION TO OTHER COWLS IS
UNIFORMLY DISTRIBUTED AROUND THE PERIPHERY.
5. RESTAURE SEALING BETWEEN UPPER SURFACE
PANEL AND ENGINE UPPER COWL WITH MATERIAL
NO.08-004A (REF. AMM 20.31.00).
009

___________________________________
CLOSING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000
*****

AH

E N D

O F

T E X T

*****

30-11-62
RAI 10000-001
2-400 PAGE
5
APR 01/05

30-11-62
6

AH

AFT UPPER COWL

RAI 10000-001
APR05

30-11-62
RAI 10000-001

2-400

PAGE
6
APR 01/05

30-11-62
7

AH

REMOVAL/INSTALLATION OF
SHUT OFF VALVE.

RAI 10000-001
APR05

30-11-62
RAI 10000-001

2-400

PAGE
7
APR 01/05

30-11-65

REMOVAL/INSTALLATION OF
DRAINS WATER

RAI 10000-001
1

APR05

ZONING DATA
___________
ZONE
ACCESS

: 435
445
: 435AL 445AL

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

GSE

: 01 ACCESS PLATFORM

SPARE

: 01 WATER DRAIN
01 WATER DRAIN

301160-08-250
301160-09-250

EXPENDABLE

: 01 SEAL
01 SEAL
00 LOKWIRE

301160-08-260
301160-09-260

BULK MATERIAL : GREASE

_________
MAN-HOURS

04-020

PUBLICATION
___________
JIC
JIC

: OPENING AND CLOSING OF


HINGED ENGINE COWLS
: OPERATIONAL TEST OF
EMPENNAGE WATER DRAIN
OPENING

AH

54-00-00-OAC-10000
30-11-33-OPT-10000

30-11-65
RAI 10000-001
2-400 PAGE
1
APR 01/05

30-11-65

REMOVAL/INSTALLATION OF
DRAINS WATER

001

RAI 10000-001
2

APR05

___________
PREPARATION
1. POSITION PLATFORM TO GAIN ACCESS TO WATER
DRAIN 5039DM (5040DM).
.
2. OPEN ENGINE COWL 435AL (445AL).
NOTE : THE FOLLOWING REMOVAL/INSTALLATION
PROCEDURE CONCERNS BOTH WATER DRAIN
5039DM, LOCATED ON THE LEFT ENGINE
AND WATER DRAIN 5040DM, LOCATED ON
THE RIGHT ENGINE.

002

___________________________________
OPENING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000

003

_______________________
REMOVAL
OF WATER DRAINS
REF. FIG. 301165-RAI-00100
1. CUT LOCKWIRE (4).
2. REMOVE WATER DRAIN (1).
3. DISCARD SEAL (2).
4. BLANK OPEN AIR DUCT (3).

004

____________________________
INSTALLATION
OF WATER DRAINS
REF. FIG. 301165-RAI-00100
1. CLEAN AND INSPECT COMPONENT INTERFACE AND/OR
ADJACENT AREA.
2. REMOVE BLANKING CAP.
3. POSITION NEW SEAL (2) ON WATER DRAIN (1),
COAT THREAD WITH MATERIAL 04-020.
*** CONTINUED ***
AH

30-11-65
RAI 10000-001
2-400 PAGE
2
APR 01/05

30-11-65

REMOVAL/INSTALLATION OF
DRAINS WATER

RAI 10000-001
3

APR05

4. INSTALL WATER DRAIN (1) ON AIR DUCT (3).


TIGHTEN (TORQUE VALUE 1,2 A 1,5 M.DAN/106,19
A 132,74 LBF.IN).
WIRELOCK.
005

_______________________________________
OPERATIONAL
TEST OF WATER DRAIN OPENING
SEE JOB INSTRUCTION CARD
301133-OPT-10000.

006

________
CLOSE-UP
1. MAKE CERTAIN THAT WORKING AREA IS CLEAN AND
CLEAR OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
2. CLOSE ENGINE COWL 435AL (445AL).
3. REMOVE ACCESS PLATFORM.

007

___________________________________
CLOSING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000
*****

AH

E N D

O F

T E X T

*****

30-11-65
RAI 10000-001
2-400 PAGE
3
APR 01/05

30-11-65
4

AH

REMOVAL AND INSTALLATION


OF WATER DRAIN

RAI 10000-001
APR05

30-11-65
RAI 10000-001

2-400

PAGE
4
APR 01/05

30-11-66

REMOVAL/INSTALLATION OF
OVERHEAT THERMAL SWITCH

RAI 10000-001
1

MAR14

ZONING DATA
___________
ZONE
ACCESS

: 435
445
: 435AL 445AL

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

GSE

: 01 ACCESS PLATFORM

SPARE

: 01 OVERHEAT THERMAL SWITCH


01 OVERHEAT THERMAL SWITCH

301160-08-270
301160-09-270

EXPENDABLE

: 01 SEAL
01 SEAL

301160-08-300
301160-09-300

BULK MATERIAL : GREASE


LOCKWIRE

_________
MAN-HOURS

04-020

PUBLICATION
___________
JIC
JIC

: OPENING AND CLOSING OF


HINGED ENGINE COWLS
: OPERATIONAL TEST OF
AIRFOIL DE-ICING SYSTEM

AH

54-00-00-OAC-10000
30-11-00-OPT-10000

30-11-66
RAI 10000-001
2-400 PAGE
1
MAR 01/14

30-11-66

REMOVAL/INSTALLATION OF
OVERHEAT THERMAL SWITCH

001

RAI 10000-001
2

MAR14

___________
PREPARATION
1. INSTALL PLATFORM TO GAIN ACCESS TO OVERHEAT
THERMAL SWITCH 73DM (74DM).
2. OPEN ENGINE COWL 435AL (445AL).
NOTE : THE FOLLOWING REMOVAL/INSTALLATION
PROCEDURE CONCERNS BOTH THERMAL
SWITCH 73DM LOCATED ON THE LEFT
ENGINE AND THERMAL SWITCH 74DM
LOCATED ON THE RIGHT ENGINE.

002

___________________________________
OPENING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000

003

__________________________________
REMOVAL
OF OVERHEAT THERMAL SWITCH
REF. FIG. 301166-RAI-00100
1. DISCONNECT ELECTRICAL CONNECTOR (1).
2. CUT AND REMOVE LOCKWIRE.
3. UNTIGHTEN AND REMOVE OVERHEAT THERMAL
SWITCH (2).
4. REMOVE AND DISCARD SEAL (3).
5. INSTALL BLANKING CAPS ON THE LINE (4) AND
CONNECTOR (1).

004

_______________________________________
INSTALLATION
OF OVERHEAT THERMAL SWITCH
REF. FIG. 301166-RAI-00100
1. CLEAN AND INSPECT COMPONENT INTERFACE
AND/OR ADJACENT AREA.
*** CONTINUED ***
AH

30-11-66
RAI 10000-001
2-400 PAGE
2
MAR 01/14

30-11-66

REMOVAL/INSTALLATION OF
OVERHEAT THERMAL SWITCH

RAI 10000-001
3

MAR14

2. REMOVE BLANKING CAPS.


3. INSTALL NEW O-RING (3) ON OVERHEAT THERMAL
SWITCH (2).
COAT THREAD WITH GREASE 04-020.
4. INSTALL THERMAL SWITCH (2) ON AIR DUCT (4).
TIGHTEN (TORQUE VALUE 1,2 A 1,5 M.DAN/106,1
A 132,7 LBF.IN) AND LOCKWIRED.
5. CONNECT ELECTRICAL CONNECTOR.
005

OPERATIONAL TEST OF BOOTS A AND B


_________________________________
CONTROLLERS
___________
SEE JOB INSTRUCTION CARD
301100-OPT-10000

006

________
CLOSE-UP
1. MAKE CERTAIN THAT WORKING AREA IS CLEAN AND
CLEAR OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
2. CLOSE ENGINE COWL 435AL (445AL).
3. REMOVE ACCESS PLATFORM.

007

___________________________________
CLOSING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000
*****

AH

E N D

O F

T E X T

*****

30-11-66
RAI 10000-001
2-400 PAGE
3
MAR 01/14

30-11-66
4

AH

REMOVAL AND INSTALLATION


OF OVERHEAT THERMAL
SWITCH

RAI 10000-001
MAR14

30-11-66
RAI 10000-001

2-400

PAGE
4
MAR 01/14

30-11-71

REMOVAL AND INSTALLATION


OF AIR BLEED PRESSURE
SWITCH

RAI 10000-001
1

MAR12

ZONING DATA
___________
ZONE
ACCESS

: 290
: 291BL

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

GSE

: 01 ACCESS PLATFORM

SPARE

: 01 AIR BLEED PRESSURE SWITCH

301170-20-030

EXPENDABLE

: 01 O-RING
00 LOCKWIRE

301170-20-060

BULK MATERIAL : GREASE

_________
MAN-HOURS

04-020

PUBLICATION
___________
JIC
JIC

: REMOVAL AND INSTALLATION


OF WING-TO-FUSELAGE
FAIRINGS
: OPERATIONAL TEST OF AIR
FOIL DE-ICING SYSTEM

AH

53-93-00-RAI-10000
30-11-00-OPT-10000

30-11-71
RAI 10000-001
2-400 PAGE
1
MAR 01/12

30-11-71

REMOVAL AND INSTALLATION


OF AIR BLEED PRESSURE
SWITCH

001

RAI 10000-001
2

MAR12

___________
PREPARATION
1. INSTALL ACCESS PLATFORM TO GAIN ACCESS TO
PRESSURE SWITCH 18DM.
2. REMOVE ACCESS PANEL 291BL.

002

____________________________________
REMOVAL
OF WING-TO-FUSELAGE FAIRINGS
SEE JOB INSTRUCTION CARD
539300-RAI-10000

003

___________________________________
REMOVAL
OF AIRBLEED PRESSURE SWITCH
REF. FIG. 301171-RAI-00101
1. DISCONNECT ELECTRICAL CONNECTOR (4).
2. LOOSEN AND REMOVE PRESSURE SWITCH (3).
3. REMOVE AND DISCARD SEAL (1).
4. INSTALL BLANKING PLUGS ON :
- ELECTRICAL CONNECTOR (4),
- PRESSURE SWITCH (3),
- UNION (2).

004

_________________________________________
INSTALLATION
OF AIR BLEED PRESSURE SWITCH
REF. FIG. 301171-RAI-00101
1. CLEAN AND INSPECT EQUIPMENT INSTALLATION
AREA.
2. REMOVE BLANKS.
3. INSTALL NEW SEAL (1) ON PRESSURE SWITCH (3).
LUBRICATE PRESSURE SWITCH THREADS WITH
MATERIAL 04-020.
4. INSTALL PRESSURE SWITCH (3) ON COUPLING (2),
*** CONTINUED ***
AH

30-11-71
RAI 10000-001
2-400 PAGE
2
MAR 01/12

30-11-71

REMOVAL AND INSTALLATION


OF AIR BLEED PRESSURE
SWITCH

RAI 10000-001
3

MAR12

(TORQUE VALUE 1,2 TO 1,5 M.DAN/106,2 TO


132,7 LBF.IN). WIRELOCK.
5. CONNECT ELECTRICAL CONNECTOR (4).
005

OPERATIONAL TEST OF AIR FOIL DE-ICING SYSTEM


____________________________________________
WITH EACH REGULATOR VALVE
_________________________
SEE JOB INSTRUCTION CARD
301100-OPT-10000

006

________
CLOSE-UP
1. CHECK THAT WORKING AREA IS CLEAN AND CLEAR
OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
2. INSTALL ACCESS PANEL 291BL.
3. REMOVE ACCESS PLATFORM.

007

_________________________________________
INSTALLATION
OF WING-TO-FUSELAGE FAIRINGS
SEE JOB INSTRUCTION CARD
539300-RAI-10000
*****

AH

E N D

O F

T E X T

*****

30-11-71
RAI 10000-001
2-400 PAGE
3
MAR 01/12

30-11-71
4

AH

REMOVAL/INSTALLATION
FOR AIR BLEED
PRESSURE SWITCH

RAI 10000-001
MAR12

30-11-71
RAI 10000-001

2-400

PAGE
4
MAR 01/12

30-11-72

REMOVAL/INSTALLATION OF
WING CENTER LINE DUAL
DISTRIBUTOR VALVE

RAI 10000-001
1

MAR12

ZONING DATA
___________
ZONE

: 512
612

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

SPARE

: 01 VALVE-DE ICING DUAL LH


01 VALVE-DE ICING DUAL RH

301170-09-080
301170-11-090

EXPENDABLE

: 02
01
02
01

301170-09-070
301170-09-050
301170-11-080
301170-11-060

O-RING
O-RING
O-RING
O-RING

___
MEN

(UNION
(UNION
(UNION
(UNION

VALVE
VALVE
VALVE
VALVE

_________
MAN-HOURS

BULK MATERIAL : GREASE

LH)
LH)
RH)
RH)

04-004

PUBLICATION
___________
JIC
JIC
JIC
JIC

: REMOVE/INSTALLATION OF
WING LEADING EDGES GENERAL
: OPERATIONAL TEST OF AIR
FOIL DE-ICING SYSTEM
: FUNCTIONAL TEST OF
ELECTRICAL HEATERS
: REMOVAL/INSTALLATION OF
WING LEADING EDGES GENERAL

AH

57-40-00-RAI-10000
30-11-00-OPT-10000
30-11-00-FUT-10000
57-40-00-RAI-10000

30-11-72
RAI 10000-001
2-400 PAGE
1
MAR 01/12

30-11-72

REMOVAL/INSTALLATION OF
WING CENTER LINE DUAL
DISTRIBUTOR VALVE

001

RAI 10000-001
2

MAR12

___________
PREPARATION
1. ON PANEL 122VU, OPEN, SAFETY AND TAG THE
FOLLOWING CIRCUIT BREAKERS:
2DM
3DM
52DM
112DM

ANTI/DE ICING/ENG2 &


SPLY & V HTG CTL
ANTI/DE ICING/ENG1 &
ANTI/DE ICING/ENG2 &
SPLY
ANTI/DE ICING/AFR DE
SPLY

AFR BOOTS B/NORM


AFR BOOTS A/SPLY
AFR BOOTS B/EMER
ICING VALVES HTG

2. INSTALL ACCESS PLATFORM TO GAIN ACCES TO


WINGS DUAL DISTRIBUTOR VALVES 83DM OR 84DM.
3. REMOVE LEADING EDGE 512 AND 612.
002

_____________________________________
REMOVE
OF WING LEADING EDGES - RIB 13
SEE JOB INSTRUCTION CARD
574000-RAI-10000
NOTE : REMOVE CENTER BOX LEADING EDGE AT RIB 13
(512 OR 612).

003

_________________________________
REMOVAL
OF DUAL DISTRIBUTOR VALVE
REF. FIG. 301172-RAI-00100
1. DISCONNECT ELECTRICAL CONNECTORS (13) AND
(14).
2. DISCONNECT SUPPLY LINE (10).
3. REMOVE LINES (11) AND (12).
4. REMOVE SCREWS (8) AND WASHERS (9).
5. REMOVE DUAL VALVE DISTRIBUTOR (

).

*** CONTINUED ***


AH

30-11-72
RAI 10000-001
2-400 PAGE
2
MAR 01/12

30-11-72

REMOVAL/INSTALLATION OF
WING CENTER LINE DUAL
DISTRIBUTOR VALVE

RAI 10000-001
3

MAR12

6. INSTALL BLANKING CAP ON LINES AND ELECTRICAL


CONNECTORS.
7. REMOVE COUPLINGS (1) AND (2) AND THEIR
O-RING (3) AND (4).
8. REMOVE DRAIN-COUPLING (5) AND ITS O-RING
(7).
004

______________________________________
INSTALLATION
OF DUAL DISTRIBUTOR VALVE
REF. FIG. 301172-RAI-00100
1. INSTALL COUPLING (1) AND (2) EQUIPPED WITH
O-RING (3) AND (4). APPLY SYNTHETIC GREASE
04.004 ON COUPLING THREADS.
2. TIGHTEN COUPLING (1) AND (2). (TIGHTENING
TORQUE 35.4 TO 39.09 LBF.FT/4.8 TO
5.3 M.DAN).
3. INSTALL DRAIN-COUPLING (5) EQUIPPED WITH ITS
NUT (6) AND ITS O-RING (7). APPLY SYNTHETIC
GREASE 04.004 ON COUPLING THREADS.
4. ADJUST COUPLING-DRAIN AT THEORETICAL DIMENSION 46.1 MORE OR LESS 1 TURN (COUPLING
AXIS TO CONTACT OF VALVE).
5. DON}T TIGHTEN NUT (6).
6. CLEAN AND INSPECT COMPONENT INTERFACE AND/OR
ADJACENT AREA.
7. REMOVE BLANKING CAP.
8. INSTALL DUAL VALVE DISTRIBUTOR WITH SCREWS
(8) AND WASHERS (9).
9. INSTALL LINES (11) AND (12) AND TIGHTEN
NIPPLES. (TIGHTENING TORQUE 28.8 TO
*** CONTINUED ***
AH

30-11-72
RAI 10000-001
2-400 PAGE
3
MAR 01/12

30-11-72

REMOVAL/INSTALLATION OF
WING CENTER LINE DUAL
DISTRIBUTOR VALVE

RAI 10000-001
4

MAR12

31.7 LBF.FT/3.9 TO 4.3 M.DAN).


10.ALIGN COUPLING (5) WITH LINE (10) WITH OUT
CONNECTING LINE.
11.TIGHTEN NUT (6). (TIGHTENING TORQUE 35.4 TO
39.09 LBF. FT/4.8 TO 5.3 M.DAN).
12.CONNECT SUPPLY LINES (10). (TIGHTENING
TORQUE 35.4 TO 39.09 LBF.FT/4.8 TO
5.3 M.DAN).
13.CONNECT ELECTRICAL CONNECTORS (13) AND (14).
005

OPERATIONAL TEST OF AIR FOIL DE-ICING SYSTEM


____________________________________________
WITH EACH REGULATOR VALVE
_________________________
SEE JOB INSTRUCTION CARD
301100-OPT-10000

006

_____________________________________
FUNCTIONAL
TEST OF ELECTRICAL HEATERS
SEE JOB INSTRUCTION CARD
301100-FUT-10000

007

________
CLOSE-UP
1. MAKE CERTAIN THAT WORKING AREA IS CLEAN AND
CLEAR OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
2. REMOVE ACCESS PLATFORM AFTER CLOSING LEADING
EDGES 512 AND 612.
3. ON PANEL 122VU, CLOSE CIRCUIT BREAKERS
PREVIOUSLY CITED.

008

INSTALLATION OF WING LEADING EDGE - RIB 11


__________________________________________
AND RIB 13.
___________
SEE JOB INSTRUCTION CARD
*** CONTINUED ***
AH

30-11-72
RAI 10000-001
2-400 PAGE
4
MAR 01/12

30-11-72

REMOVAL/INSTALLATION OF
WING CENTER LINE DUAL
DISTRIBUTOR VALVE

RAI 10000-001
5

MAR12

574000-RAI-10000
NOTA : INSTALL CENTER BOX LEADING EDGE AT RIB
11 (511 OR 611) AND RIB 13 (512 OR 612).
*****

AH

E N D

O F

T E X T

*****

30-11-72
RAI 10000-001
2-400 PAGE
5
MAR 01/12

30-11-72
6

AH

REMOVAL/INSTALLATION OF
DUAL DISTRIBUTOR VALVE

RAI 10000-001
MAR12

30-11-72
RAI 10000-001

2-400

PAGE
6
MAR 01/12

30-11-72

REMOVAL/INSTALLATION OF
OUTER WING DUAL
DISTRIBUTOR VALVE

RAI 10010-001
1

MAR12

ZONING DATA
___________
ZONE

: 514
614

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

SPARE

: 01 VALVE-DE ICING DUAL

301170-08-080

EXPENDABLE

: 01 PLATFORM
02 O-RING
01 O-RING

301170-08-070
301170-08-050

BULK MATERIAL : GREASE

_________
MAN-HOURS

04-004

PUBLICATION
___________
JIC
JIC
JIC

: REMOVAL/INSTALLATION OF
LEADING EDGES
: OPERATIONAL TEST OF AIR
FOIL DE-ICING SYSTEM
: FUNCTIONAL TEST OF
ELECTRICAL HEATERS

AH

57-40-00-RAI-10000
30-11-00-OPT-10000
30-11-00-FUT-10000

30-11-72
RAI 10010-001
2-400 PAGE
1
MAR 01/12

30-11-72

REMOVAL/INSTALLATION OF
OUTER WING DUAL
DISTRIBUTOR VALVE

001

RAI 10010-001
2

MAR12

___________
PREPARATION
1. ON PANEL 122VU, OPEN, SAFETY AND TAG THE
FOLLOWING CIRCUIT BREAKERS:
2DM
3DM
52DM
112DM

ANTI/DE ICING/ENG2 &


SPLY & V HTG CTL
ANTI/DE ICING/ENG1 &
ANTI/DE ICING/ENG2 &
SPLY
ANTI/DE ICING/AFR DE
SPLY

AFR BOOTS B/NORM


AFR BOOTS A/SPLY
AFR BOOTS B EMER
ICING VALVES HTG

2. INSTALL ACCESS PLATFORM TO GAIN ACCES TO


WING DUAL DISTRIBUTOR VALVES 9DM OR 10DM.
3. REMOVE LEADING EDGE 514 AND 614.
002

________________________
REMOVAL
OF LEADING EDGES
SEE JOB INSTRUCTION CARD
574000-RAI-10000

003

_________________________________
REMOVAL
OF DUAL DISTRIBUTOR VALVE
REF. FIG. 301172-RAI-00110
1. DISCONNECT ELECTRICAL CONNECTORS (13) AND
(14).
2. DISCONNECT SUPPLY LINE (10).
3. UNTIGHTEN CLAMPS (15) AND (16).
4. DISCONNECT LINES (11) AND (12).
5. REMOVE SCREWS (8) AND WASHERS (9).
6. REMOVE DUAL VALVE DISTRIBUTOR.
7. INSTALL BLANKING CAP ON LINES AND ELECTRICAL
*** CONTINUED ***
AH

30-11-72
RAI 10010-001
2-400 PAGE
2
MAR 01/12

30-11-72

REMOVAL/INSTALLATION OF
OUTER WING DUAL
DISTRIBUTOR VALVE

RAI 10010-001
3

MAR12

CONNECTORS.
8. REMOVE COUPLINGS (1) AND (2) AND THEIR
O-RING (3) AND (4).
9. REMOVE DRAIN-COUPLING (5) AND ITS O-RING
(7).
004

______________________________________
INSTALLATION
OF DUAL DISTRIBUTOR VALVE
REF. FIG. 301172-RAI-00110
1. INSTALL COUPLING (1) AND (2) EQUIPED WITH
O-RING (3) AND (4). APPLY SYNTHETIC GREASE
04.004 ON COUPLING THREADS.
2. TIGHTEN COUPLING (1) AND (2). (TIGHTENING
TORQUE 37.1 TO 37.9 LBF.FT/5.03 TO
5.14 M.DAN).
3. INSTALL DRAIN-COUPLING (5) EQUIPPED WITH ITS
NUT (6) AND ITS O-RING (7). APPLY SYNTHETIC
GREASE 04.004 ON COUPLING THREADS.
4. ADJUST COUPLING-DRAIN AT THEORETICAL DIMENSION 46.1 MM MORE OR LESS 1 TURN (COUPLING
AXIS TO CONTACT OF VALVE).
5. DON}T TIGHTEN NUT (6).
6. CLEAN AND INSPECT COMPONENT INTERFACE AND/OR
ADJACENT AREA.
7. REMOVE BLANKING CAP.
8. INSTALL DUAL VALVE DISTRIBUTOR WITH SCREWS
(8) AND WASHERS (9).
9. INSTALL LINES (11) AND (12) AND TIGHTEN
NIPPLES. (TIGHTENING TORQUE 28.8 TO
31.7 LBF.FT/3.9 TO 4.3 M.DAN).
*** CONTINUED ***
AH

30-11-72
RAI 10010-001
2-400 PAGE
3
MAR 01/12

30-11-72

REMOVAL/INSTALLATION OF
OUTER WING DUAL
DISTRIBUTOR VALVE

RAI 10010-001
4

MAR12

10.TIGHTEN CLAMPS (15) AND (16). (TIGHTENING


TORQUE 25.8 LBF.IN/2.8 M.N).
11.ALIGN COUPLING (5) WITH LINE (10) WITH OUT
CONNECTING LINE.
12.TIGHTEN NUT (6). (TIGHTENING TORQUE 35.4 TO
39.09 LBF. FT/4.8 TO 5.3 M.DAN).
13.CONNECT SUPPLY LINES (10). (TIGHTENING
TORQUE 35.4 TO 39.09 LBF.FT/4.8 TO
5.3 M.DAN).
14.CONNECT ELECTRICAL CONNECTORS (13) AND (14).
005

OPERATIONAL TEST OF AIR FOIL DE-ICING SYSTEM


____________________________________________
WITH EACH REGULATOR VALVE
_________________________
SEE JOB INSTRUCTION CARD
301100-OPT-10000

006

_____________________________________
FUNCTIONAL
TEST OF ELECTRICAL HEATERS
SEE JOB INSTRUCTION CARD
301100-FUT-10000

007

________
CLOSE-UP
1. MAKE CERTAIN THAT WORKING AREA IS CLEAN AND
CLEAR OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
2. REMOVE ACCESS PLATFORM AFTER CLOSING LEADING
EDGES 514 AND 614.
3. ON PANEL 122VU, CLOSE CIRCUIT BREAKERS
PREVIOUSLY CITED.

*** CONTINUED ***


AH

30-11-72
RAI 10010-001
2-400 PAGE
4
MAR 01/12

30-11-72

REMOVAL/INSTALLATION OF
OUTER WING DUAL
DISTRIBUTOR VALVE

008

RAI 10010-001
5

MAR12

_____________________________
INSTALLATION
OF LEADING EDGES
SEE JOB INSTRUCTION CARD
574000-RAI-10000
*****

AH

E N D

O F

T E X T

*****

30-11-72
RAI 10010-001
2-400 PAGE
5
MAR 01/12

30-11-72
6

AH

REMOVAL/INSTALLATION OF
DUAL DISTRIBUTOR VALVE

RAI 10010-001
MAR12

30-11-72
RAI 10010-001

2-400

PAGE
6
MAR 01/12

30-11-74

REMOVAL AND INSTALLATION


OF AILERON HORN

RAI 10000-001
1

APR05

ZONING DATA
___________
ZONE
ACCESS

: 544
644
: 544AL
644AR

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

GSE

: 01 ACCESS PLATFORM

SPARE

: 01 AILERON HORN
01 AILERON HORN

LH
RH

BULK MATERIAL : SPECIAL MATERIAL


GREASE
SEALING PRODUCT

_________
MAN-HOURS

576111-06-180
576111-06-190
05-027
04-003
09-018

PUBLICATION
___________
JIC
JIC

: BALANCE OF AILERON
SPRING TAB AFTER REPLACEMENT OF DE-ICED HORN
: OPERATIONAL TEST OF
ANTI-ICING AND WARNING
OF EACH HORN

AH

57-61-00-ADJ-10020
30-11-00-OPT-10030

30-11-74
RAI 10000-001
2-400 PAGE
1
APR 01/05

30-11-74

REMOVAL AND INSTALLATION


OF AILERON HORN

001

RAI 10000-001
2

APR05

___________
PREPARATION
1. INSTALL ACCESS PLATFORM TO GAIN ACCESS TO
TO AILERON HORNS.
2. OPEN SAFETY AND TAG THE FOLLOWING CIRCUIT
BREAKERS :
ON PANEL
50DM
48DM
ON PANEL
34DM

126VU,
HORNS ANTI ICING PWR SPLY/R AIL
HORNS ANTI ICING PWR SPLY/L AIL
122VU,
ANTI/DE ICING/HORNS CTL & IND/
AIL & R ELEV

CAUTION : INSTALL WARNING NOTICE IN FLIGHT COMPARTMENT PROHIBITING OPERATION OF


RUDDER CONTROL.
002

_______________________
REMOVAL
OF AILERON HORN
REF. FIG. 301174-RAI-00100
1. REMOVE HORN ATTACHMENT SCREWS (1).
2. REMOVE HORN.
3. DICONNECT ELECTRICAL CONNECTOR (2) AND
BONDING STRIP (3).
4. CAP CONNECTOR AND TAPE TO AILERON.
NOTE : THIS REMOVAL PROCEDURE CONCERNS LEFT
HORN. REMOVAL OF RIGHT HORN IS
IDENTICAL.

003

___________________
BALANCE
OF AILERONS
SEE JOB INSTRUCTION CARD
576100-ADJ-10020
*** CONTINUED ***
AH

30-11-74
RAI 10000-001
2-400 PAGE
2
APR 01/05

30-11-74

REMOVAL AND INSTALLATION


OF AILERON HORN

004

RAI 10000-001
3

APR05

_____________________________
INSTALLATION
OF AILERON HORN.
REF. FIG. 301174-RAI-00100
1. CHECK FOR CORRECT CONDITION OF ELECTRICAL
CONNECTOR AND VISIBLE SECTION OF WIRING.
PROTECT CONNECTOR AND CONNECTOR SOCKET WITH
MATERIAL N0. 05-027.
CHECK FOR CORROSION IN HORN INSTALLATION
AREA.
2. COAT THREADS OF CAPTIVE NUTS (4) WITH
MATERIAL N0. 04-003.
3. CONNECT ELECTRICAL CONNECTOR (2) AND BONDING
STRIP (3).
4. COAT THE SURFACE WHESE THE HORN MUST BE
INSTALLED WITH SEALING PRODUCT 09-018.
INSTALL HORN ON RUDDER. INSTALL AND TIGHTEN
SCREWS (3).
NOTE : THIS INSTALLATION PROCEDURE CONCERNS
LEFT HORN. RIGHT HORN INSTALLATION
IS IDENTICAL.

005

OPERATIONAL TEST OF HORN ANTI ICING


___________________________________
AND WARNING
___________
SEE JOB INSTRUCTION CARD
301100-OPT-10030

006

________
CLOSE-UP
1. MAKE CERTAIN THAT WORKING AREA IS CLEAN AND
CLEAR OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
2. REMOVE ACCESS PLATFORM.
*****

AH

E N D

O F

T E X T

*****

30-11-74
RAI 10000-001
2-400 PAGE
3
APR 01/05

30-11-74
4

AH

REMOVAL AND INSTALLATION


OF AILERON HORN

RAI 10000-001
APR05

30-11-74
RAI 10000-001

2-400

PAGE
4
APR 01/05

30-11-75

REMOVAL/INSTALLATION OF
OUTER WING DE-ICER

RAI 10000-001
1

APR05

ZONING DATA
___________

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

AH

___
MEN

_________
MAN-HOURS

30-11-75
RAI 10000-001
2-400 PAGE
1
APR 01/05

30-11-75

REMOVAL/INSTALLATION OF
OUTER WING DE-ICER

001

RAI 10000-001
2

APR05

___________________________________________
REMOVAL/INSTALLATION
OF OUTER WING DE-ICER.
FOR REMOVAL/INSTALLATION OF THE OUTER WING
DE-ICER (5001DM, 5002DM, 5007DM AND 5008DM)
SEE CMM/M 57-43-12
LEADING EDGE ASSY
*****

AH

E N D

O F

T E X T

*****

30-11-75
RAI 10000-001
2-400 PAGE
2
APR 01/05

30-11-75

REMOVAL/INSTALLATION OF
CENTER WING DE-ICER

RAI 10010-001
1

APR05

ZONING DATA
___________

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

AH

___
MEN

_________
MAN-HOURS

30-11-75
RAI 10010-001
2-400 PAGE
1
APR 01/05

30-11-75

REMOVAL/INSTALLATION OF
CENTER WING DE-ICER

001

RAI 10010-001
2

APR05

____________________________________________
REMOVAL/INSTALLATION
OF CENTER WING DE-ICER.
FOR REMOVAL/INSTALLATION OF THE CENTER WING
DE-ICER (5003DM AND 5004DM) SEE CMM/M 57-43-11
LEADING EDGE ASSY
*****

AH

E N D

O F

T E X T

*****

30-11-75
RAI 10010-001
2-400 PAGE
2
APR 01/05

30-11-75

REMOVAL/INSTALLATION OF
INNER WING DE-ICER

RAI 10020-001
1

APR05

ZONING DATA
___________

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

AH

___
MEN

_________
MAN-HOURS

30-11-75
RAI 10020-001
2-400 PAGE
1
APR 01/05

30-11-75

REMOVAL/INSTALLATION OF
INNER WING DE-ICER

001

RAI 10020-001
2

APR05

___________________________________________
REMOVAL/INSTALLATION
OF INNER WING DE-ICER.
FOR REMOVAL/INSTALLATION OF THE INNER WING
DE-ICER (5005DM AND 5006DM) SEE CMM/M 57-42-11
LEADING EDGE ASSY
*****

AH

E N D

O F

T E X T

*****

30-11-75
RAI 10020-001
2-400 PAGE
2
APR 01/05

30-11-76

OPERATIONAL TEST OF
WING PIPES WATER DRAINS

OPT 10000-001
1

MAR11

ZONING DATA
___________
ZONE
ACCESS

: 512
612
: 292CR 293AL
435AL 445AL

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

GSE

: 02 ACCESS PLATFORM 3M (10FT)


01 COMPRESSOR

_________
MAN-HOURS

PUBLICATION
___________
JIC
JIC
JIC

: REMOVAL AND INSTALLATION


OF WING-TO-FUSELAGE
FAIRINGS
: REMOVAL/INSTALLATION OF
LEADING EDGES
: OPENING AND CLOSING OF
HINGED ENGINE COWLS

AH

53-93-00-RAI-10000
57-40-00-RAI-10000
54-00-00-OAC-10000

30-11-76
OPT 10000-001
2-400 PAGE
1
MAR 01/11

30-11-76

OPERATIONAL TEST OF
WING PIPES WATER DRAINS

001

OPT 10000-001
2

MAR11

___________
PREPARATION
1. INSTALL ACCESS PLATFORM, SO AS TO HAVE
ACCESS TO FOLLOWING EQUIPMENT :
- ON ENGINE L (R)
. VALVE SHUT OFF REGULATOR 13DM (14DM),
. ENGINE WATER DRAIN.
2. OPEN ENGINE COWLS 435AL AND 445AL.
3. POSITION PLATFORM TO GAIN ACCESS TO WATER
DRAINS LOCATED IN WING LEADING EDGES AND IN
KARMAN.
4. REMOVE LEADING EDGE 512 AND 612 AND KARMAN
PANEL 293AL AND 292CR.

002

____________________________________
REMOVAL
OF WING-TO-FUSELAGE FAIRINGS
SEE JOB INSTRUCTION CARD
539300-RAI-10000

003

________________________
REMOVAL
OF LEADING EDGES
SEE JOB INSTRUCTION CARD
574000-RAI-10000

004

___________________________________
OPENING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000

005

_____________________________________
OPERATIONAL
TEST OF PIPE WATER DRAINS
REF. FIG. 301176-OPT-00100
REF. FIG. 301100-OPT-00110
1. UNSCREW AND REMOVE PROTECTIVE PLUG FROM
REGULATOR VALVE TEST PORT.
2. TO PERFORM TEST, CONNECT COMPRESSOR 1,5 BARS
*** CONTINUED ***
AH

30-11-76
OPT 10000-001
2-400 PAGE
2
MAR 01/11

30-11-76

OPERATIONAL TEST OF
WING PIPES WATER DRAINS

OPT 10000-001
3

MAR11

(21,75PSI) MINIMUM TO LEFT (RIGHT) ENGINE


REGULATOR AND SHUT-OFF VALVE TEST PLUG.
3. BLEED CIRCUIT WITH GROUND AIR PRESSURIZATION
UNIT.
4. INCREASE PRESSURE FROM 0 TO 0.400 BAR (5.8
PSI). CHECK THAT AIR FLOWS THROUGH EACH
DRAIN (DRAIN OPEN).
5. CONTINUE TO INCREASE PRESSURE FROM 0.400
BAR TO 2 BAR (5.8 TO 29 PSI). CHECK THAT
AIR DOES NOT FLOW THROUGH DRAINS (DRAIN
CLOSED).
6. DECREASE PRESSURE TO 0 BAR (0 PSI).
7. DISCONNECT GROUND AIR PRESSURIZATION UNIT
FROM LEFT (RIGHT) REGULATOR VALVE.
8. INSTALL PROTECTIVE PLUG ON REGULATOR VALVE
TEST PORT.
006

________
CLOSE-UP
1. MAKE CERTAIN THAT WORKING AREA IS CLEAN
AND CLEAR OF TOOLS AND MISCELLANEOUS ITEMS
OF EQUIPMENT.
2. REMOVE ACCESS PLATFORM AFTER INSTALLING
LEADING EDGES 512, 612, KARMAN PANELS 293AL
AND 292CR, AND CLOSING ENGINE COWL 435AL
(445AL) AS FOLLOWS :

007

_________________________________________
INSTALLATION
OF WING-TO-FUSELAGE FAIRINGS
SEE JOB INSTRUCTION CARD
539300-RAI-10000

*** CONTINUED ***


AH

30-11-76
OPT 10000-001
2-400 PAGE
3
MAR 01/11

30-11-76

OPERATIONAL TEST OF
WING PIPES WATER DRAINS

008

OPT 10000-001
4

MAR11

_____________________________
INSTALLATION
OF LEADING EDGES
SEE JOB INSTRUCTION CARD
574000-RAI-10000

009

___________________________________
CLOSING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000
*****

AH

E N D

O F

T E X T

*****

30-11-76
OPT 10000-001
2-400 PAGE
4
MAR 01/11

30-11-76
5

AH

WATER DRAIN

OPT 10000-001
MAR11

30-11-76
OPT 10000-001

2-400

PAGE
5
MAR 01/11

30-11-76
6

AH

TEST COUPLING - PRESSURE


REGULATOR AND SHUT-OFF
VALVE

OPT 10000-001
MAR11

30-11-76
OPT 10000-001

2-400

PAGE
6
MAR 01/11

30-11-76

OPERATIONAL TEST OF
WING PIPES WATER DRAINS

OPT 10000-002
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 512
612
: 292CR 293AL
435AL 445AL

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

GSE

: 02 ACCESS PLATFORM 3M (10FT)


01 COMPRESSOR

_________
MAN-HOURS

PUBLICATION
___________
JIC
JIC
JIC

: REMOVAL AND INSTALLATION


OF WING-TO-FUSELAGE
FAIRINGS
: REMOVAL/INSTALLATION OF
LEADING EDGES
: OPENING AND CLOSING OF
HINGED ENGINE COWLS

AH

53-93-00-RAI-10000
57-40-00-RAI-10000
54-00-00-OAC-10000

30-11-76
OPT 10000-002
2-400 PAGE
1
DEC 01/14

30-11-76

OPERATIONAL TEST OF
WING PIPES WATER DRAINS

001

OPT 10000-002
2

DEC14

___________
PREPARATION
1. INSTALL ACCESS PLATFORM, SO AS TO HAVE
ACCESS TO FOLLOWING EQUIPMENT :
- ON ENGINE L (R)
. VALVE SHUT OFF REGULATOR 13DM (14DM),
. ENGINE WATER DRAIN.
2. OPEN ENGINE COWLS 435AL AND 445AL.
3. POSITION PLATFORM TO GAIN ACCESS TO WATER
DRAINS LOCATED IN WING LEADING EDGES AND IN
KARMAN.
4. REMOVE LEADING EDGE 512 AND 612 AND KARMAN
PANEL 293AL AND 292CR.

002

____________________________________
REMOVAL
OF WING-TO-FUSELAGE FAIRINGS
SEE JOB INSTRUCTION CARD
539300-RAI-10000

003

________________________
REMOVAL
OF LEADING EDGES
SEE JOB INSTRUCTION CARD
574000-RAI-10000

004

___________________________________
OPENING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000

005

_____________________________________
OPERATIONAL
TEST OF PIPE WATER DRAINS
REF. FIG. 301176-OPT-00100
REF. FIG. 301100-OPT-00110
1. UNSCREW AND REMOVE PROTECTIVE PLUG FROM
REGULATOR VALVE TEST PORT.
2. TO PERFORM TEST, CONNECT GROUND AIR PRES*** CONTINUED ***
AH

30-11-76
OPT 10000-002
2-400 PAGE
2
DEC 01/14

30-11-76

OPERATIONAL TEST OF
WING PIPES WATER DRAINS

OPT 10000-002
3

DEC14

SURIZATION UNIT 4 BARS (58 PSI) (60L/SEC)


TO LEFT REGULATOR VALVE TEST PORT 1.
3. BLEED CIRCUIT WITH GROUND AIR PRESSURIZATION
UNIT.
4. INCREASE PRESSURE FROM 0 TO 0.400 BAR (5.8
PSI). CHECK THAT AIR FLOWS THROUGH EACH
DRAIN (DRAIN OPEN).
5. CONTINUE TO INCREASE PRESSURE FROM 0.400
BAR TO 2 BAR (5.8 TO 29 PSI). CHECK THAT
AIR DOES NOT FLOW THROUGH DRAINS (DRAIN
CLOSED).
6. DECREASE PRESSURE TO 0 BAR (0 PSI).
7. DISCONNECT GROUND AIR PRESSURIZATION UNIT
FROM LEFT (RIGHT) REGULATOR VALVE.
8. INSTALL PROTECTIVE PLUG ON REGULATOR VALVE
TEST PORT.
006

________
CLOSE-UP
1. MAKE CERTAIN THAT WORKING AREA IS CLEAN
AND CLEAR OF TOOLS AND MISCELLANEOUS ITEMS
OF EQUIPMENT.
2. REMOVE ACCESS PLATFORM AFTER INSTALLING
LEADING EDGES 512, 612, KARMAN PANELS 293AL
AND 292CR, AND CLOSING ENGINE COWL 435AL
(445AL) AS FOLLOWS :

007

_________________________________________
INSTALLATION
OF WING-TO-FUSELAGE FAIRINGS
SEE JOB INSTRUCTION CARD
539300-RAI-10000

*** CONTINUED ***


AH

30-11-76
OPT 10000-002
2-400 PAGE
3
DEC 01/14

30-11-76

OPERATIONAL TEST OF
WING PIPES WATER DRAINS

008

OPT 10000-002
4

DEC14

_____________________________
INSTALLATION
OF LEADING EDGES
SEE JOB INSTRUCTION CARD
574000-RAI-10000

009

___________________________________
CLOSING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000
*****

AH

E N D

O F

T E X T

*****

30-11-76
OPT 10000-002
2-400 PAGE
4
DEC 01/14

30-11-76
5

AH

WATER DRAIN

OPT 10000-002
DEC14

30-11-76
OPT 10000-002

2-400

PAGE
5
DEC 01/14

30-11-76
6

AH

TEST COUPLING - PRESSURE


REGULATOR AND SHUT-OFF
VALVE

OPT 10000-002
DEC14

30-11-76
OPT 10000-002

2-400

PAGE
6
DEC 01/14

30-11-76

REMOVAL/INSTALLATION OF
WING PIPES WATER DRAINS

RAI 10010-001
1

APR05

ZONING DATA
___________
ZONE
ACCESS

: 290
512
612
: 292CR 293AL

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

GSE

: 01 ACCESS PLATFORM

SPARE

: 01 WATER DRAIN
01 WATER DRAIN

301170-20
301120-02

EXPENDABLE

: 00 O-RING
00 O-RING
00 LOCKWIRE

301170-20
301120-02

BULK MATERIAL : GREASE

_________
MAN-HOURS

04-019

PUBLICATION
___________
JIC
JIC
JIC

: REMOVAL AND INSTALLATION


OF WING-TO-FUSELAGE
FAIRINGS
: REMOVAL/INSTALLATION OF
LEADING EDGES
: OPERATIONAL TEST OF
PIPES WATER DRAIN OF
WINGS.

AH

53-93-00-RAI-10000
57-40-00-RAI-10000
30-11-76-OPT-10000

30-11-76
RAI 10010-001
2-400 PAGE
1
APR 01/05

30-11-76

REMOVAL/INSTALLATION OF
WING PIPES WATER DRAINS

001

RAI 10010-001
2

APR05

___________
PREPARATION
1. POSITION PLATFORM TO GAIN ACCESS TO WATER
DRAINS.
2. REMOVE ACCESS PANEL OR LEADING EDGES CORRESPONDING TO WATER DRAIN REMOVED :
- ACCES PANEL 292CR WATER DRAIN 5034DM
- ACCES PANEL 293AL WATER DRAIN 5033DM
- LEADING EDGE 512 WATER DRAIN 5031DM
- LEADING EDGE 612 WATER DRAIN 5032DM

002

____________________________________
REMOVAL
OF WING-TO-FUSELAGE FAIRINGS
SEE JOB INSTRUCTION CARD
539300-RAI-10000

003

________________________
REMOVAL
OF LEADING EDGES
SEE JOB INSTRUCTION CARD
574000-RAI-10000

004

_______________________
REMOVAL
OF WATER DRAINS
REF. FIG. 301176-RAI-00100
1. CUT LOCKWIRE (4).
2. REMOVE WATER DRAIN (1).
3. DISCARD SEAL (2).
4. BLANK OPEN AIR DUCT (3).

005

____________________________
INSTALLATION
OF WATER DRAINS
REF. FIG. 301176-RAI-00100
1. CLEAN AND INSPECT COMPONENT INTERFACE AND/OR
ADJACENT AREA.
*** CONTINUED ***
AH

30-11-76
RAI 10010-001
2-400 PAGE
2
APR 01/05

30-11-76

REMOVAL/INSTALLATION OF
WING PIPES WATER DRAINS

RAI 10010-001
3

APR05

2. REMOVE BLANKING CAP.


3. POSITION NEW SEAL (2) ON WATER DRAIN (1),
COAT THREAD WITH MATERIAL 04-019.
4. INSTALL WATER DRAIN (1) ON UNION (3),
TIGHTEN (TORQUE VALUE 1,2 A 1,5 M.DAN/106,19
A 132,74 LBF.IN).
WIRELOCK.
006

_______________________________________________
OPERATIONAL
TEST OF PIPES WATER DRAINS OF WINGS
SEE JOB INSTRUCTION CARD
301176-OPT-10000.

007

________
CLOSE-UP
1. MAKE CERTAIN THAT WORKING AREA IS CLEAN
AND CLEAR OF TOOLS AND MISCELLANEOUS ITEMS
OF EQUIPMENT.
2. INSTALL ACCES PANEL.
3. REMOVE PLATFORM.

008

_________________________________________
INSTALLATION
OF WING-TO-FUSELAGE FAIRINGS
SEE JOB INSTRUCTION CARD
539300-RAI-10000

009

_____________________________
INSTALLATION
OF LEADING EDGES
SEE JOB INSTRUCTION CARD
574000-RAI-10000
*****

AH

E N D

O F

T E X T

*****

30-11-76
RAI 10010-001
2-400 PAGE
3
APR 01/05

30-11-76
4

AH

REMOVAL/INSTALLATION
OF LINE WATER DRAINS

RAI 10010-001
APR05

30-11-76
RAI 10010-001

2-400

PAGE
4
APR 01/05

30-11-82

REMOVAL/INSTALLATION OF
HORN ANTI ICING
CONTROLLERS

RAI 10000-001
1

APR05

ZONING DATA
___________
ZONE
ACCESS

: 214
: 214BZ

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

_________
MAN-HOURS

ELAPSED TIME

SPARE

: 02 CONTROLLERS

301180-02-130

: OPERATIONAL TEST OF
ANTI-ICING AND WARNING
OF EACH HORN

30-11-00-OPT-10030

PUBLICATION
___________
JIC

AH

30-11-82
RAI 10000-001
2-400 PAGE
1
APR 01/05

30-11-82

REMOVAL/INSTALLATION OF
HORN ANTI ICING
CONTROLLERS

001

RAI 10000-001
2

APR05

___________
PREPARATION
1. ON PANEL 122VU, OPEN SAFETY AND TAG THE
FOLLOWING CIRCUIT BREAKERS:
32DM
33DM
34DM
48DM
50DM
51DM
63DM

HORNS ANTI ICING PWR SPLY/R ELEV


ANTI/DE ICING/HORNS CTL & IND/RUD
& L ELEV
ANTI/DE ICING/HORNS CTL & IND/AIL
& R ELEV
HORNS ANTI ICING PWR SPLY/L AIL
HORNS ANTI ICING PWR SPLY/R AIL
HORNS ANTI ICING PWR SPLY/RUD
HORNS ANTI ICING PWR SPLY/L ELEV

2. THE FOLLOWING REMOVAL/INSTALLATION OPERATION


ARE APPLICABLE TO CONTROLLERS 57DM AND 58DM
LOCATED ON SHELVES 93VU AND 94VU OF ELECTRICAL RACK 90VU.
3. OPEN ACCESS PANEL 214BZ.
002

REMOVAL OF EQUIPMENT FROM L OR R ELECTRONICS


____________________________________________
RACKS 80VU OR 90VU
__________________
NOTE: THE QUANTITY OF FIXING SCREWS AS WELL AS
THE SHAPE AND QUANTITY OF CONNECTORS MAY
BE DIFFERENT ACCORDING THE EQUIPMENT.
NEVERTHELESS, THE REMOVAL AND INSTALLATION PROCEDURE IS IDENTICAL.
REF. FIG. 310000-RAI-00106
1. REMOVE ACCESS DOOR.
2. DISCONNECT ELECTRICAL CONNECTOR(S) (2).
3. INSTALL PROTECTIVE CAP(S) ON EQUIPMENT
SIDE ELECTRICAL CONNECTOR(S).
4. UNSCREW EQUIPMENT ATTACHMENT SCREWS (3).
*** CONTINUED ***
AH

30-11-82
RAI 10000-001
2-400 PAGE
2
APR 01/05

30-11-82

REMOVAL/INSTALLATION OF
HORN ANTI ICING
CONTROLLERS

RAI 10000-001
3

APR05

5. REMOVE EQUIPMENT (1) FROM ITS SHELF (4).


003

INSTALLATION OF EQUIPMENT IN L OR R ELECTRONICS


_______________________________________________
RACKS 80VU AND 90VU
___________________
REF. FIG. 310000-RAI-00106
1. CLEAN AND INSPECT EQUIPMENT (1) AND SHELF
(4) INTERFACE AREA.
2. LOCATE EQUIPMENT (1) AND ATTACH TO SHELF(4)
BY MEANS OF ATTACHMENT SCREWS (3).
3. REMOVE PROTECTIVE CAP(S) FROM EQUIPMENT SIDE
ELECTRICAL CONNECTOR(S) (2).
4. CONNECT ELECTRICAL CONNECTOR(S) (2).
5.REMOVE ACCESS DOOR

004

OPERATIONAL TEST OF HORN ANTI ICING


___________________________________
AND WARNING
___________
SEE JOB INSTRUCTION CARD
301100-OPT-10030

005

________
CLOSE-UP
1. MAKE CERTAIN THAT WORKING AREA IS CLEAN AND
CLEAR OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
2. CLOSE ACCESS PANEL 214BZ.
3. CLOSE CIRCUIT BREAKERS MENTIONED ABOVE.
*****

AH

E N D

O F

T E X T

*****

30-11-82
RAI 10000-001
2-400 PAGE
3
APR 01/05

30-11-82
4

AH

R ELECTRONICS RACK
90VU EQUIPMENT

RAI 10000-001
APR05

30-11-82
RAI 10000-001

2-400

PAGE
4
APR 01/05

30-11-83

REMOVAL/INSTALLATION OF
STANDBY DE-ICING CONTROL
UNIT

RAI 10000-001
1

APR05

ZONING DATA
___________
ZONE
ACCESS

: 210
: 214BZ

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

_________
MAN-HOURS

ELAPSED TIME

SPARE

: 01 CONTROLLER-DE ICING, STBY

301180-02

: OPERATIONAL TEST OF
STANDBY DE ICING SYSTEM

30-00-00-OPT-10000

PUBLICATION
___________
JIC

AH

30-11-83
RAI 10000-001
2-400 PAGE
1
APR 01/05

30-11-83

REMOVAL/INSTALLATION OF
STANDBY DE-ICING CONTROL
UNIT

001

RAI 10000-001
2

APR05

___________
PREPARATION
1. ON PANEL 122VU, OPEN, SAFETY AND TAG THE
FOLLOWING CIRCUIT BREAKERS :
2DM ANTI/DE ICING/ENG2 & AFR-BOOTS B NORM
SPLY & V HTG CTL
3DM ANTI/DE ICING/ENG1 & AFR-BOOTS A SPLY
52DM ANTI/DE ICING/ENG2 & AFR-BOOTS B EMER
SPLY
2. REMOVE PANEL 214BZ TO GAIN ACCESS TO STANDBY DE ICING CONTROL UNIT 109DM LOCATED ON
SHELF 93VU OF ELECTRICAL RACK 90VU.

002

_______________________________________
REMOVAL
OF STANDBY DE ICING CONTOL UNIT
REF.FIG.301183-RAI-00100
1. DISCONNECT ELECTRICAL CONNECTOR (1).
2. RELEASE SCREWS (3).
3. DISENGAGE CONTROL UNIT (2) FROM ITS SUPPORT
(4).
4. INSTALL PROTECTIVE CAPS ON ELECTRICAL CONNECTORS.

003

INSTALLATION OF STANDBY DE ICING CONTROL


________________________________________
UNIT.
_____
REF.FIG.301183-RAI-00100
1. REMOVE PROTECTION CAPS FROM ELECTRICAL
CONNECTOR.
2. CLEAN AND INSPECT COMPONENT INTERFACE AND
/OR ADJACENT AREA.
3. INSTALL CONTROL UNIT (2) IN ITS SUPPORT (4)
*** CONTINUED ***
AH

30-11-83
RAI 10000-001
2-400 PAGE
2
APR 01/05

30-11-83

REMOVAL/INSTALLATION OF
STANDBY DE-ICING CONTROL
UNIT

RAI 10000-001
3

APR05

4. TIGHTEN SCREWS (3).


5. CONNECT ELECTRICAL CONNECTORS (1).
004

OPERATIONAL TEST OF STANDBY DE ICING


____________________________________
SYSTEM
______
SEE JOB INSTRUCTION CARD
300000-OPT-10000

005

________
CLOSE-UP
1. MAKE CERTAIN THAT WORKING AREA IS CLEAN AND
CLEAR OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
2. CLOSE ACCESS DOOR 214BZ, ON ELECTRICAL
RACK 90VU.
3. ON PANEL 122VU, CLOSE CIRCUIT BREAKERS
PREVIOUSLY MENTION.
*****

AH

E N D

O F

T E X T

*****

30-11-83
RAI 10000-001
2-400 PAGE
3
APR 01/05

30-11-83
4

AH

REMOVAL/INSTALLATION OF
STANDBY CONTROL UNIT

RAI 10000-001
APR05

30-11-83
RAI 10000-001

2-400

PAGE
4
APR 01/05

30-21-00

DETAILLED VISUAL
INSPECTION OF ENGINES
DE-ICERS HOSES

DVI 10000-001
1

APR05

ZONING DATA
___________
ZONE
ACCESS

: 435
436
445
446
: 435AL 436AR 445AL 446AR

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

GSE

: 01 ACCESS PLATFORM

_________
MAN-HOURS

PUBLICATION
___________
JIC
JIC

: OPENING AND CLOSING OF


HINGED ENGINE COWLS
: REMOVAL/INSTALLATION OF
ENGINE AIR INTAKE COWL

AH

54-00-00-OAC-10000
54-12-61-RAI-10020

30-21-00
DVI 10000-001
2-400 PAGE
1
APR 01/05

30-21-00

DETAILLED VISUAL
INSPECTION OF ENGINES
DE-ICERS HOSES

001

DVI 10000-001
2

APR05

___________
PREPARATION
1. INSTALL ACCESS PLATFORM TO GAIN ACCESS TO
FOLLOWING EQUIPMENTS :
.
.
.
.

DE-ICER
DE-ICER
DE-ICER
DE-ICER

AIR
GAS
GAS
OIL

INTAKE LIP,
PATH THROAT,
PATH FLOOR,
COOLER UPPER GAS.

2. OPEN ENGINE PANELS 435AL (445AL) AND 436AR


(446AR).
3. PARTLY REMOVE ENGINE AIR INTAKE COWL TO
ACCES TO HOSES OF AIR INTAKE LIP DE-ICER.
002

_______________________
OPENING
OF HINGED COWLS
SEE JOB INSTRUCTION CARD
540000-OAC-10000

003

_________________________________
REMOVAL
OF ENGINE AIR INTAKE COWL
SEE JOB INSTRUCTION CARD
541261-RAI-10020

004

__________________________________
VISUAL
INSPECTION OF DE-ICER HOSES
INSPECT DE-ICER HOSES AND CHECK FOR :
- CRACK,
- WEAR,
- RUPTURE.

005

________
CLOSE-UP
1. MAKE CERTAIN THAT WORKING AREA IS CLEAN AND
CLEAR OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
2. INSTALL ENGINE AIR INTAKE.
*** CONTINUED ***
AH

30-21-00
DVI 10000-001
2-400 PAGE
2
APR 01/05

30-21-00

DETAILLED VISUAL
INSPECTION OF ENGINES
DE-ICERS HOSES

DVI 10000-001
3

APR05

3. REMOVE ACCESS PLATFORM AFTER HAVING CLOSED


ENGINE COWLS 435AL(436AR) AND 445AL(446AR).
006

______________________________________
INSTALLATION
OF ENGINE AIR INTAKE COWL
SEE JOB INSTRUCTION CARD
541261-RAI-10020

007

______________________________
CLOSING
OF HINGED ENGINE COWLS
SEE JOB INSTRUCTION CARD
540000-OAC-10000
*****

AH

E N D

O F

T E X T

*****

30-21-00
DVI 10000-001
2-400 PAGE
3
APR 01/05

30-21-00
4

AH

ENGINE DE-ICERS

DVI 10000-001
APR05

30-21-00
DVI 10000-001

2-400

PAGE
4
APR 01/05

30-21-00

OPERATIONAL TEST OF
ENGINE AIR INTAKE DEICING SYSTEM

OPT 10000-003
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 210
435
445
: 435AL 445AL

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

GSE

: 01 ACCESS PLATFORM
01 COMPRESSOR

_________
MAN-HOURS

PUBLICATION
___________
JIC
JIC
JIC
JIC

: OPENING AND CLOSING OF


HINGED ENGINE COWLS
: READING OF MFC
MAINTENANCE MEMORY
: ERASURE OF MFC
MAINTENANCE MEMORY
: DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY

AH

54-00-00-OAC-10000
45-13-00-RDG-10000
45-13-00-RON-10000
24-46-00-EAD-10000

30-21-00
OPT 10000-003
2-400 PAGE
1
DEC 01/14

30-21-00

OPERATIONAL TEST OF
ENGINE AIR INTAKE DEICING SYSTEM

001

OPT 10000-003
2

DEC14

___________
PREPARATION
1. INSTALL ACCESS PLATFORM SO AS TO HAVE ACCESS
TO FOLLOWING EQUIPMENTS :
- ON ENGINE L AND R
. VALVE SHUT OFF REGULATOR
. DUAL DISTRIBUTOR VALVE
2. OPEN ENGINE PANELS 435AL (455AL).
3. BY MEANS OF THE BELOW PROCEDURE CHECK IF
SYSTEM BOOTS FAILURE IS MEMORIZED IN
MFC MAINTENANCE MEMORY.

002

___________________________________
OPENING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000

003

_________________________________
READING
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RDG-10000

004

_________________________________
ERASURE
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RON-10000
NOTE:THIS TASK MUST BE PERFORMED ONLY IF FAULTS
RELATIVE TO THE SYSTEM TO BE CHECKED HAVE
BEEN RECORDED BY THE MFC MAINTENANCE
MEMORY.

005

ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


___________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

*** CONTINUED ***


AH

30-21-00
OPT 10000-003
2-400 PAGE
2
DEC 01/14

30-21-00

OPERATIONAL TEST OF
ENGINE AIR INTAKE DEICING SYSTEM

006

OPT 10000-003
3

DEC14

OPERATIONAL TEST OF ENGINE AIR INTAKE


_____________________________________
DE-ICING SYSTEM (PART 1/3)
__________________________
REF. FIG. 301100-OPT-00100, 301100-OPT-00110,
301100-CHK-00110.
TO PERFORM TEST, CONNECT COMPRESSOR 4 BARS
(58 PSI) (60 L/SEC) TO LEFT ENGINE REGULATOR
AND SHUT-OFF VALVE TEST PLUG.
NOTE :THIS TEST CAN BE PERFORMED ALSO WITH 1
ROTATING ENGINE.
ENGINES COWLS CLOSED. AFTER AN ENGINE
REPLACEMENT,PERFORM TEST DURING ENGINE
ADJUSTMENT AT RUN-UP.
1. ON PANEL 702VU,
PLACE SWITCH WEIGHT ON WHEELS IN FLT
POSITION.
2. ON PANEL 24VU,
A. CHECK THAT AFR AIR BLEED PUSHBUTTON
SWITCH (2) IS PRESSED (IN):
- FAULT LEGEND OFF,
- OFF LEGEND OFF.
B. PRESS MODE SEL/AUTO PUSHBUTTON
SWITCH (5) :
- FAULT LEGEND OFF,
- MAN LEGEND ON.
C. CHECK THAT MODE SEL PUSHBUTTON
SWITCH (1) IS RELEASED (OUT):
- SLOW LEGEND OFF.
D. PRESS ENG1 AND ENG2 PUSHBUTTON
SWITCHES (6) AND (7) :
- FAULT LEGENDS OFF,
- ON LEGENDS ON.
3. WAIT DE ICING CYCLE I.E. 60 SECONDS :
- NO WARNING MUST APPEAR.
*** CONTINUED ***
AH

30-21-00
OPT 10000-003
2-400 PAGE
3
DEC 01/14

30-21-00

OPERATIONAL TEST OF
ENGINE AIR INTAKE DEICING SYSTEM

OPT 10000-003
4

DEC14

4. ON PANEL 24VU,
PRESS MODE SEL PUSHBUTTON SWITCH (1):
- SLOW LEGEND ON.
5. WAIT COMPLETE DE ICING CYCLE I.E. 180
SECONDS :
- NO WARNING MUST APPEAR.
NOTE: PERFORM THIS TEST ONLY WHEN THIS TEST IS
PERFORMED WITH A COMPRESSOR.
CHECK MANUALLY AND AURALLY FOR AIR
LEAKAGE OF REGULATOR AND SHUTOFF VALVES
(5) AND (8)AT LEVEL OF REGULATION BELLOWS
(12) LOCATED UNDER THE VALVES,AND FOR AIR
LEAKAGE OF DUAL DISTRIBUTOR VALVES (6)
AND (7) AND AIR JET PUMPS (13) LOCATED AT
THE UPPER END OF THE VALVES.
DURING THE DE ICERS BOOTS A AND B INFLATE
CHECK VISUALY THE ALL DE ICERS SURFACE
THE ABSENCE OF FLATULENCE OR UNGLUING.
6. ON PANEL 24VU,
RELEASE MODE SEL PUSHBUTTON SWITCH (1):
- SLOW LEGEND OFF.
7. ON PANEL 25VU,
RELEASE (7UA1) MFC/1A AND (6UA1) MFC/1B
PUSHBUTTON SWITCHES (8) AND (9) :
- FAULT LEGEND OFF,
- OFF LEGEND ON.
8. WAIT DE ICING CYCLE I.E. 60 SECONDS. NO
WARNING MUST APPEAR.
9. ON PANEL 24VU,
PRESS MODE SEL PUSHBUTTON SWITCH (1):
- SLOW LEGEND ON.
10.WAIT DE ICING CYCLE I.E. 180 SECONDS.
NO WARNING MUST APPEAR.
*** CONTINUED ***
AH

30-21-00
OPT 10000-003
2-400 PAGE
4
DEC 01/14

30-21-00

OPERATIONAL TEST OF
ENGINE AIR INTAKE DEICING SYSTEM

OPT 10000-003
5

DEC14

11.ON PANEL 25VU,


A. PRESS (7UA1) MFC/1A AND (6UA1) MFC/1B
PUSHBUTTON SWITCHES (8) AND (9) :
- FAULT LEGENDS OFF,
- OFF LEGENDS OFF.
B. WAIT DE ICING CYCLE I.E. 180 SECONDS.
C. RELEASE (7UA2) MFC/2A AND (6UA2)
MFC/2B PUSHBUTTON SWITCHES (10) AND
(11).
- FAULT LEGENDS OFF,
- OFF LEGENDS ON.
12.WAIT DE ICING CYCLE I.E. 180 SECONDS.
NO WARNING MUST APPEAR.
13.ON PANEL 24VU,
RELEASE MODE SEL PUSHBUTTON SWITCH (1):
- SLOW LEGEND OFF.
14.WAIT DE ICING CYCLE I.E. 60 SECONDS.
NO WARNING MUST APPEAR.
15.ON PANEL 25VU,
PRESS (7UA2) MFC/2A AND (6UA2) MFC/2B
PUSHBUTTON SWITCHES (10) AND (11) :
- FAULT LEGENDS OFF,
- OFF LEGENDS OFF.
NOTE : BY MEANS OF THE PROCEDURE BELLOW MAKE
SURE THAT THE FOLLOWING FAILURE ARE NOT
MEMORIZED IN BOOTS MFC MAINTENANCE
MEMORY :
- LEFT ENGINE BOOT A FAULT
- RIGHT ENGINE BOOT A FAULT
- LEFT ENGINE BOOT B FAULT
- RIGHT ENGINE BOOT B FAULT

*** CONTINUED ***


AH

30-21-00
OPT 10000-003
2-400 PAGE
5
DEC 01/14

30-21-00

OPERATIONAL TEST OF
ENGINE AIR INTAKE DEICING SYSTEM

007

OPT 10000-003
6

DEC14

_________________________________
READING
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RDG-10000

008

OPERATIONAL TEST OF ENGINE AIR INTAKE


_____________________________________
DE-ICING SYSTEM (PART 2/3)
__________________________
REF. FIG. 301100-OPT-00100, 301100-OPT-00110
301100-CHK-00110.
1. PLACE THE CONDITION LEVER (CLA) ON AUTO
POSITION.
2. ON COMPRESSOR OR ON ENGINE SHUT DOWN AIR
SUPPLY PRESSURE SYSTEM ALLOW TO PRESSURE
DROP.
3. ON PANEL 24VU,
ON AFR AIR BLEED PUSHBUTTON SWITCH (2):
- FAULT LEGEND ON,
- OFF LEGEND OFF.
4. FOLLOWING WARNINGS APPEAR :
- ON CAP, ANTI-ICING ANNUNCIATOR COMES ON.
- CAUTION ANNUNCIATORS COME ON,
- SINGLE CHIME SOUNDS.
5. ON PANEL 24VU,
ON ENG1 AND ENG2 PUSHBUTTON SWITCHES
(6) AND (7) :
- FAULT LEGEND LIGHT FLASHES EVERY 2,5S
AT THEORICAL CYCLE INFLATING OF BOOTS A
AND B,
- ON LEGEND ON.
6. ON PANEL 25VU, MAKE THE FOLLOWING OPERATIONS :
- RELEASE (7UA1) MFC/1A PUSHBUTTON SWITCH
(8),
- WAIT DE ICING CYCLE I.E. 60 SECONDS,
*** CONTINUED ***
AH

30-21-00
OPT 10000-003
2-400 PAGE
6
DEC 01/14

30-21-00

OPERATIONAL TEST OF
ENGINE AIR INTAKE DEICING SYSTEM

OPT 10000-003
7

DEC14

- PRESS (7UA1) MFC/1A PUSHBUTTON SWITCH


(8),
- RELEASE (7UA2) MFC/2A PUSHBUTTON SWITCH
(10),
- WAIT DE ICING CYCLE I.E. 60 SECONDS,
- PRESS (7UA2) MFC/2A PUSHBUTTON SWITCH
(10).
7. DURING ABOVE OPERATIONS, WARNINGS REMAINS
ON.
8. ON PANEL 24VU,
A. RELEASE AFR AIR BLEED PUSHBUTTON
SWITCH (2) :
- FAULT LEGEND OFF,
- OFF LEGEND ON.
B. ON ENG1 AND ENG2 PUSHBUTTON
SWITCHES (6) AND (7) :
- FAULT LEGENDS ON,
- ON LEGENDS ON.
9. WARNINGS REMAINS ON.
10.ON PANEL 25VU, MAKE THE FOLLOWING OPERATIONS :
- RELEASE (7UA1) MFC/1A PUSHBUTTON SWITCH
(8),
- WAIT DE ICING CYCLE I.E. 60 SECONDS,
- PRESS (7UA1) MFC/1A PUSHBUTTON SWITCH
(8),
- RELEASE (6UA1) MFC/1B PUSHBUTTON SWITCH
(9),
- WAIT DE ICING CYCLE I.E. 60 SECONDS,
- PRESS (6UA1) MFC/1B PUSHBUTTON SWITCH
(9),
- WAIT DE ICING CYCLE I.E. 60 SECONDS,
- RELEASE (7UA2) MFC/2A PUSHBUTTON SWITCH
(10),
- WAIT DE ICING CYCLE I.E. 60 SECONDS,
- PRESS (7UA2) MFC/2A PUSHBUTTON SWITCH
*** CONTINUED ***
AH

30-21-00
OPT 10000-003
2-400 PAGE
7
DEC 01/14

30-21-00

OPERATIONAL TEST OF
ENGINE AIR INTAKE DEICING SYSTEM

OPT 10000-003
8

DEC14

(10).
- RELEASE (6UA2) MFC/2B PUSHBUTTON SWITCH
(11),
- WAIT DE ICING CYCLE I.E. 60 SECONDS,
- PRESS (6UA2) MFC/2B PUSHBUTTON SWITCH
(11).
11.DURING ABOVE OPERATIONS, WARNINGS REMAINS
ON.
12.ON PANEL 24VU,
A. PRESS AFR AIR BLEED PUSHBUTTON
SWITCH (2) :
- FAULT LEGEND ON,
- OFF LEGEND OFF.
B. RESET ENG1 AND ENG2 PUSHBUTTON
SWITCHES (6) AND (7) :
- FAULT LEGEND LIGHT FLASHES EVERY 2,5S
AT THEORICAL CYCLE INFLATING OF BOOTS
A AND B,
- ON LEGENDS ON.
13.APPLY AIR PRESSURE TO SYSTEM OR RUN-UP
ENGINE.
14.WARNINGS DESAPPEAR.
15.ON PANEL 24VU,
A. ON AFR AIR BLEED PUSHBUTTON SWITCH (2):
- FAULT LEGEND OFF,
- OFF LEGEND OFF.
B. ON ENG1 AND ENG2 PUSHBUTTON
SWITCHES (6) AND (7) :
- FAULT LEGENDS OFF,
- ON LEGENDS ON.
16.ON PANEL 702VU,
PLACE WEIGHT ON WEELS SWITCH ON NORM.
*** CONTINUED ***
AH

30-21-00
OPT 10000-003
2-400 PAGE
8
DEC 01/14

30-21-00

OPERATIONAL TEST OF
ENGINE AIR INTAKE DEICING SYSTEM

009

OPT 10000-003
9

DEC14

OPERATIONAL TEST OF ENGINE AIR INTAKE


_____________________________________
DE-ICING SYSTEM (PART 3/3)
__________________________
REF. FIG. 301100-OPT-00100, 301100-OPT-00110
301100-CHK-00110
1. ON PANEL 702VU,
PLACE WEIGHT ON WHEELS SWITCH ON FLT
POSITION.
2. ON PANEL 24VU,
PRESS AIR FRAME PUSHBUTTON SWITCH (3):
- FAULT LEGEND OFF,
- ON LEGEND ON.
3. ON PANEL 402VU,
CHECK THAT ANTI ICING ANNUNCIATOR
(4) IS ON.
4. SHUTT DOWN AIR SUPPLY PRESSURE IN SYSTEM
OR SHUTT OF THE ENGINE, ALLOW TO PRESSURE
DROP.
5. ON PANEL 24VU,
A. RELEASE ENG1 PUSHBUTTON SWITCH (6):
- FAULT LEGEND OFF,
- ON LEGEND OFF.
B. ON ENG2 PUSHBUTTON SWITCH (7) :
- FAULT LIGHT 2,5S DURING INFLATING
OF LEFT ENGINE BOOTS A AND B,
- ON LEGEND ON.
C. ON AFR AIR BLEED PUSHBUTTON SWITCH (2):
- FAULT LEGEND ON,
- OFF LEGEND OFF.
6. FOLLOWINGS WARNINGS APPEAR :
- ON CAP, ANTI ICING ANNUNCIATOR COMES
ON,
- CAUTION ANNUNCIATORS COME ON,
- SINGLE CHIME SOUNDS.
*** CONTINUED ***
AH

30-21-00
OPT 10000-003
2-400 PAGE
9
DEC 01/14

30-21-00

OPERATIONAL TEST OF
ENGINE AIR INTAKE DEICING SYSTEM

OPT 10000-003
10

DEC14

7. ON PANEL 24VU,
A. RELEASE AFR AIR BLEED PUSHBUTTON
SWITCH (2) :
- FAULT LEGEND OFF,
- OFF LEGEND ON.
B. ON AIR FRAME PUSHBUTTON SWITCH (3):
- FAULT LEGEND ON,
- ON LEGEND ON.
C. ON ENG2 PUSHBUTTON SWITCH (7) :
- FAULT LEGEND ON,
- ON LEGEND ON.
8. WARNINGS REMAINS ON.
9. APPLY AIR PRESSURE TO SYSTEM OR RUN-UP
ENGINE.
10.ON PANEL 24VU,
A. PRESS ENG1 PUSHBUTTON SWITCH (6):
- FAULT LEGEND OFF,
- ON LEGEND ON.
B. PRESS AFR AIR BLEED PUSHBUTTON
SWITCH (2) :
- FAULT LEGEND OFF,
- OFF LEGEND OFF.
C. RESET ENG2 PUSHBUTTON SWITCH (7):
- FAULT LEGEND OFF,
- ON LEGEND ON.
D. RESET AIR FRAME PUSHBUTTON SWITCH(3):
- FAULT LEGEND OFF,
- ON LEGEND ON.
11.WARNINGS DESAPPEAR.
12.ON PANEL 24VU,
A. RELEASE AIR FRAME, ENG1 AND ENG2
PUSHBUTTON SWITCHES (3), (6) AND (7):
- FAULT LEGENDS OFF,
*** CONTINUED ***
AH

30-21-00
OPT 10000-003
2-400 PAGE
10
DEC 01/14

30-21-00

OPERATIONAL TEST OF
ENGINE AIR INTAKE DEICING SYSTEM

OPT 10000-003
11

DEC14

- ON LEGENDS OFF.


B. RELEASE MODE SEL/AUTO PUSHBUTTON
SWITCHES (5) :
- FAULT LEGENDS OFF,
- MAN LEGENDS OFF.
13.ON PANEL 402VU, CHECK THAT DE ICING
ANNUNCIATOR (4) IS OFF.
14.PLACE THE CONDITION LEVER (CLA) ON FUEL SO
POSITION.
15.ON PANEL 702VU,
PLACE WEIGHT ON WHEELS SWITCH ON NORM
POSITION.
16.DISCONNECT GROUND AIR PRESSURIZATION UNIT
OR SHUT OFF ENGINE.
NOTE : A. REPEAT TEST WITH GROUND AIR
PRESSURIZATION UNIT CONNECTED
TO REGULATOR AND SHUT OFF VALVE
ON RIGHT ENGINE.
IN ABOVE PROCEDURE, REPLACE
PUSHBUTTON SWITCHES :
ENG1 (6) BY ENG2 (7)
ENG2 (7) BY ENG1 (6)
B. BY MEAN OF THE PROCEDURE BELLOW
MAKE SURE THAT THE FOLLOWING
FAILURE ARE MEMORIZED IN BOOTS
MFC MAINTENANCE MEMORY :
- LEFT ENGINE BOOT A FAULT
- RIGHT ENGINE BOOT A FAULT
- LEFT ENGINE BOOT B FAULT
- RIGHT ENGINE BOOT B FAULT

*** CONTINUED ***


AH

30-21-00
OPT 10000-003
2-400 PAGE
11
DEC 01/14

30-21-00

OPERATIONAL TEST OF
ENGINE AIR INTAKE DEICING SYSTEM

010

OPT 10000-003
12

DEC14

_________________________________
READING
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RDG-10000

011

_________________________________
ERASURE
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RON-10000

012

DE-ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


______________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

013

________
CLOSE-UP
1. MAKE CERTAIN THAT WORKING AREA IS CLEAN AND
CLEAR OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
2. REMOVE ACCESS PLATFORMS AFTER HAVING CLOSED
ENGINE COWLS 435AL AND 445AL.

014

___________________________________
CLOSING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000
*****

AH

E N D

O F

T E X T

*****

30-21-00
OPT 10000-003
2-400 PAGE
12
DEC 01/14

30-21-00
13

AH

CONTROLS AND INDICATING


WING/ENGINE DE ICING

OPT 10000-003
DEC14

30-21-00
OPT 10000-003

2-400

PAGE
13
DEC 01/14

30-21-00
14

AH

TEST COUPLING - PRESSURE


REGULATOR AND SHUT-OFF
VALVE

OPT 10000-003
DEC14

30-21-00
OPT 10000-003

2-400

PAGE
14
DEC 01/14

30-21-00
15

AH

CHECK OF REGULATOR VALVE


AND DUAL DISTRIBUTOR
VALVES AIR LEAKAGE.

OPT 10000-003
DEC14

30-21-00
OPT 10000-003

2-400

PAGE
15
DEC 01/14

30-21-00

OPERATIONAL TEST OF
ENGINE AIR INTAKE DEICING SYSTEM

OPT 10000-004
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 210
435
445
: 435AL 445AL

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

GSE

: 01 ACCESS PLATFORM
01 COMPRESSOR

_________
MAN-HOURS

PUBLICATION
___________
JIC
JIC
JIC
JIC

: OPENING AND CLOSING OF


HINGED ENGINE COWLS
: READING OF MFC
MAINTENANCE MEMORY
: ERASURE OF MFC
MAINTENANCE MEMORY
: DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY

AH

54-00-00-OAC-10000
45-13-00-RDG-10000
45-13-00-RON-10000
24-46-00-EAD-10000

30-21-00
OPT 10000-004
2-400 PAGE
1
DEC 01/14

30-21-00

OPERATIONAL TEST OF
ENGINE AIR INTAKE DEICING SYSTEM

001

OPT 10000-004
2

DEC14

___________
PREPARATION
1. INSTALL ACCESS PLATFORM SO AS TO HAVE ACCESS
TO FOLLOWING EQUIPMENTS :
- ON ENGINE L AND R
. VALVE SHUT OFF REGULATOR
. DUAL DISTRIBUTOR VALVE
2. OPEN ENGINE PANELS 435AL (455AL).
3. BY MEANS OF THE BELOW PROCEDURE CHECK IF
SYSTEM BOOTS FAILURE IS MEMORIZED IN
MFC MAINTENANCE MEMORY.

002

___________________________________
OPENING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000

003

_________________________________
READING
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RDG-10000

004

_________________________________
ERASURE
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RON-10000
NOTE:THIS TASK MUST BE PERFORMED ONLY IF FAULTS
RELATIVE TO THE SYSTEM TO BE CHECKED HAVE
BEEN RECORDED BY THE MFC MAINTENANCE
MEMORY.

005

ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


___________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

*** CONTINUED ***


AH

30-21-00
OPT 10000-004
2-400 PAGE
2
DEC 01/14

30-21-00

OPERATIONAL TEST OF
ENGINE AIR INTAKE DEICING SYSTEM

006

OPT 10000-004
3

DEC14

OPERATIONAL TEST OF ENGINE AIR INTAKE


_____________________________________
DE-ICING SYSTEM (PART 1/3)
__________________________
REF. FIG. 301100-OPT-00100, 301100-OPT-00110,
301100-CHK-00110.
TO PERFORM TEST, CONNECT GROUND AIR PRESSURIZATION UNIT 4 BARS (58 PSI) (60 L/SEC)
TO LEFT REGULATOR VALVE TEST PORT 1.
NOTE :THIS TEST CAN BE PERFORMED ALSO WITH 1
ROTATING ENGINE.
ENGINES COWLS CLOSED. AFTER AN ENGINE
REPLACEMENT,PERFORM TEST DURING ENGINE
ADJUSTMENT AT RUN-UP.
1. ON PANEL 702VU,
PLACE SWITCH WEIGHT ON WHEELS IN FLT
POSITION.
2. ON PANEL 24VU,
A. CHECK THAT AFR AIR BLEED PUSHBUTTON
SWITCH (2) IS PRESSED (IN):
- FAULT LEGEND OFF,
- OFF LEGEND OFF.
B. PRESS MODE SEL/AUTO PUSHBUTTON
SWITCH (5) :
- FAULT LEGEND OFF,
- MAN LEGEND ON.
C. CHECK THAT MODE SEL PUSHBUTTON
SWITCH (1) IS RELEASED (OUT):
- SLOW LEGEND OFF.
D. PRESS ENG1 AND ENG2 PUSHBUTTON
SWITCHES (6) AND (7) :
- FAULT LEGENDS OFF,
- ON LEGENDS ON.
3. WAIT DE ICING CYCLE I.E. 60 SECONDS :
- NO WARNING MUST APPEAR.
*** CONTINUED ***
AH

30-21-00
OPT 10000-004
2-400 PAGE
3
DEC 01/14

30-21-00

OPERATIONAL TEST OF
ENGINE AIR INTAKE DEICING SYSTEM

OPT 10000-004
4

DEC14

4. ON PANEL 24VU,
PRESS MODE SEL PUSHBUTTON SWITCH (1):
- SLOW LEGEND ON.
5. WAIT COMPLETE DE ICING CYCLE I.E. 180
SECONDS :
- NO WARNING MUST APPEAR.
NOTE: PERFORM THIS TEST ONLY WHEN THIS TEST IS
PERFORMED WITH A COMPRESSOR.
CHECK MANUALLY AND AURALLY FOR AIR
LEAKAGE OF REGULATOR AND SHUTOFF VALVES
(5) AND (8)AT LEVEL OF REGULATION BELLOWS
(12) LOCATED UNDER THE VALVES,AND FOR AIR
LEAKAGE OF DUAL DISTRIBUTOR VALVES (6)
AND (7) AND AIR JET PUMPS (13) LOCATED AT
THE UPPER END OF THE VALVES.
DURING THE DE ICERS BOOTS A AND B INFLATE
CHECK VISUALY THE ALL DE ICERS SURFACE
THE ABSENCE OF FLATULENCE OR UNGLUING.
6. ON PANEL 24VU,
RELEASE MODE SEL PUSHBUTTON SWITCH (1):
- SLOW LEGEND OFF.
7. ON PANEL 25VU,
RELEASE (7UA1) MFC/1A AND (6UA1) MFC/1B
PUSHBUTTON SWITCHES (8) AND (9) :
- FAULT LEGEND OFF,
- OFF LEGEND ON.
8. WAIT DE ICING CYCLE I.E. 60 SECONDS. NO
WARNING MUST APPEAR.
9. ON PANEL 24VU,
PRESS MODE SEL PUSHBUTTON SWITCH (1):
- SLOW LEGEND ON.
10.WAIT DE ICING CYCLE I.E. 180 SECONDS.
NO WARNING MUST APPEAR.
*** CONTINUED ***
AH

30-21-00
OPT 10000-004
2-400 PAGE
4
DEC 01/14

30-21-00

OPERATIONAL TEST OF
ENGINE AIR INTAKE DEICING SYSTEM

OPT 10000-004
5

DEC14

11.ON PANEL 25VU,


A. PRESS (7UA1) MFC/1A AND (6UA1) MFC/1B
PUSHBUTTON SWITCHES (8) AND (9) :
- FAULT LEGENDS OFF,
- OFF LEGENDS OFF.
B. WAIT DE ICING CYCLE I.E. 180 SECONDS.
C. RELEASE (7UA2) MFC/2A AND (6UA2)
MFC/2B PUSHBUTTON SWITCHES (10) AND
(11).
- FAULT LEGENDS OFF,
- OFF LEGENDS ON.
12.WAIT DE ICING CYCLE I.E. 180 SECONDS.
NO WARNING MUST APPEAR.
13.ON PANEL 24VU,
RELEASE MODE SEL PUSHBUTTON SWITCH (1):
- SLOW LEGEND OFF.
14.WAIT DE ICING CYCLE I.E. 60 SECONDS.
NO WARNING MUST APPEAR.
15.ON PANEL 25VU,
PRESS (7UA2) MFC/2A AND (6UA2) MFC/2B
PUSHBUTTON SWITCHES (10) AND (11) :
- FAULT LEGENDS OFF,
- OFF LEGENDS OFF.
NOTE : BY MEANS OF THE PROCEDURE BELLOW MAKE
SURE THAT THE FOLLOWING FAILURE ARE NOT
MEMORIZED IN BOOTS MFC MAINTENANCE
MEMORY :
- LEFT ENGINE BOOT A FAULT
- RIGHT ENGINE BOOT A FAULT
- LEFT ENGINE BOOT B FAULT
- RIGHT ENGINE BOOT B FAULT

*** CONTINUED ***


AH

30-21-00
OPT 10000-004
2-400 PAGE
5
DEC 01/14

30-21-00

OPERATIONAL TEST OF
ENGINE AIR INTAKE DEICING SYSTEM

007

OPT 10000-004
6

DEC14

_________________________________
READING
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RDG-10000

008

OPERATIONAL TEST OF ENGINE AIR INTAKE


_____________________________________
DE-ICING SYSTEM (PART 2/3)
__________________________
REF. FIG. 301100-OPT-00100, 301100-OPT-00110
301100-CHK-00110.
1. PLACE THE CONDITION LEVER (CLA) ON AUTO
POSITION.
2. ON COMPRESSOR OR ON ENGINE SHUT DOWN AIR
SUPPLY PRESSURE SYSTEM ALLOW TO PRESSURE
DROP.
3. ON PANEL 24VU,
ON AFR AIR BLEED PUSHBUTTON SWITCH (2):
- FAULT LEGEND ON,
- OFF LEGEND OFF.
4. FOLLOWING WARNINGS APPEAR :
- ON CAP, ANTI-ICING ANNUNCIATOR COMES ON.
- CAUTION ANNUNCIATORS COME ON,
- SINGLE CHIME SOUNDS.
5. ON PANEL 24VU,
ON ENG1 AND ENG2 PUSHBUTTON SWITCHES
(6) AND (7) :
- FAULT LEGEND LIGHT FLASHES EVERY 2,5S
AT THEORICAL CYCLE INFLATING OF BOOTS A
AND B,
- ON LEGEND ON.
6. ON PANEL 25VU, MAKE THE FOLLOWING OPERATIONS :
- RELEASE (7UA1) MFC/1A PUSHBUTTON SWITCH
(8),
- WAIT DE ICING CYCLE I.E. 60 SECONDS,
*** CONTINUED ***
AH

30-21-00
OPT 10000-004
2-400 PAGE
6
DEC 01/14

30-21-00

OPERATIONAL TEST OF
ENGINE AIR INTAKE DEICING SYSTEM

OPT 10000-004
7

DEC14

- PRESS (7UA1) MFC/1A PUSHBUTTON SWITCH


(8),
- RELEASE (7UA2) MFC/2A PUSHBUTTON SWITCH
(10),
- WAIT DE ICING CYCLE I.E. 60 SECONDS,
- PRESS (7UA2) MFC/2A PUSHBUTTON SWITCH
(10).
7. DURING ABOVE OPERATIONS, WARNINGS REMAINS
ON.
8. ON PANEL 24VU,
A. RELEASE AFR AIR BLEED PUSHBUTTON
SWITCH (2) :
- FAULT LEGEND OFF,
- OFF LEGEND ON.
B. ON ENG1 AND ENG2 PUSHBUTTON
SWITCHES (6) AND (7) :
- FAULT LEGENDS ON,
- ON LEGENDS ON.
9. WARNINGS REMAINS ON.
10.ON PANEL 25VU, MAKE THE FOLLOWING OPERATIONS :
- RELEASE (7UA1) MFC/1A PUSHBUTTON SWITCH
(8),
- WAIT DE ICING CYCLE I.E. 60 SECONDS,
- PRESS (7UA1) MFC/1A PUSHBUTTON SWITCH
(8),
- RELEASE (6UA1) MFC/1B PUSHBUTTON SWITCH
(9),
- WAIT DE ICING CYCLE I.E. 60 SECONDS,
- PRESS (6UA1) MFC/1B PUSHBUTTON SWITCH
(9),
- WAIT DE ICING CYCLE I.E. 60 SECONDS,
- RELEASE (7UA2) MFC/2A PUSHBUTTON SWITCH
(10),
- WAIT DE ICING CYCLE I.E. 60 SECONDS,
- PRESS (7UA2) MFC/2A PUSHBUTTON SWITCH
*** CONTINUED ***
AH

30-21-00
OPT 10000-004
2-400 PAGE
7
DEC 01/14

30-21-00

OPERATIONAL TEST OF
ENGINE AIR INTAKE DEICING SYSTEM

OPT 10000-004
8

DEC14

(10).
- RELEASE (6UA2) MFC/2B PUSHBUTTON SWITCH
(11),
- WAIT DE ICING CYCLE I.E. 60 SECONDS,
- PRESS (6UA2) MFC/2B PUSHBUTTON SWITCH
(11).
11.DURING ABOVE OPERATIONS, WARNINGS REMAINS
ON.
12.ON PANEL 24VU,
A. PRESS AFR AIR BLEED PUSHBUTTON
SWITCH (2) :
- FAULT LEGEND ON,
- OFF LEGEND OFF.
B. RESET ENG1 AND ENG2 PUSHBUTTON
SWITCHES (6) AND (7) :
- FAULT LEGEND LIGHT FLASHES EVERY 2,5S
AT THEORICAL CYCLE INFLATING OF BOOTS
A AND B,
- ON LEGENDS ON.
13.APPLY AIR PRESSURE TO SYSTEM OR RUN-UP
ENGINE.
14.WARNINGS DESAPPEAR.
15.ON PANEL 24VU,
A. ON AFR AIR BLEED PUSHBUTTON SWITCH (2):
- FAULT LEGEND OFF,
- OFF LEGEND OFF.
B. ON ENG1 AND ENG2 PUSHBUTTON
SWITCHES (6) AND (7) :
- FAULT LEGENDS OFF,
- ON LEGENDS ON.
16.ON PANEL 702VU,
PLACE WEIGHT ON WEELS SWITCH ON NORM.
*** CONTINUED ***
AH

30-21-00
OPT 10000-004
2-400 PAGE
8
DEC 01/14

30-21-00

OPERATIONAL TEST OF
ENGINE AIR INTAKE DEICING SYSTEM

009

OPT 10000-004
9

DEC14

OPERATIONAL TEST OF ENGINE AIR INTAKE


_____________________________________
DE-ICING SYSTEM (PART 3/3)
__________________________
REF. FIG. 301100-OPT-00100, 301100-OPT-00110
301100-CHK-00110
1. ON PANEL 702VU,
PLACE WEIGHT ON WHEELS SWITCH ON FLT
POSITION.
2. ON PANEL 24VU,
PRESS AIR FRAME PUSHBUTTON SWITCH (3):
- FAULT LEGEND OFF,
- ON LEGEND ON.
3. ON PANEL 402VU,
CHECK THAT ANTI ICING ANNUNCIATOR
(4) IS ON.
4. SHUTT DOWN AIR SUPPLY PRESSURE IN SYSTEM
OR SHUTT OF THE ENGINE, ALLOW TO PRESSURE
DROP.
5. ON PANEL 24VU,
A. RELEASE ENG1 PUSHBUTTON SWITCH (6):
- FAULT LEGEND OFF,
- ON LEGEND OFF.
B. ON ENG2 PUSHBUTTON SWITCH (7) :
- FAULT LIGHT 2,5S DURING INFLATING
OF LEFT ENGINE BOOTS A AND B,
- ON LEGEND ON.
C. ON AFR AIR BLEED PUSHBUTTON SWITCH (2):
- FAULT LEGEND ON,
- OFF LEGEND OFF.
6. FOLLOWINGS WARNINGS APPEAR :
- ON CAP, ANTI ICING ANNUNCIATOR COMES
ON,
- CAUTION ANNUNCIATORS COME ON,
- SINGLE CHIME SOUNDS.
*** CONTINUED ***
AH

30-21-00
OPT 10000-004
2-400 PAGE
9
DEC 01/14

30-21-00

OPERATIONAL TEST OF
ENGINE AIR INTAKE DEICING SYSTEM

OPT 10000-004
10

DEC14

7. ON PANEL 24VU,
A. RELEASE AFR AIR BLEED PUSHBUTTON
SWITCH (2) :
- FAULT LEGEND OFF,
- OFF LEGEND ON.
B. ON AIR FRAME PUSHBUTTON SWITCH (3):
- FAULT LEGEND ON,
- ON LEGEND ON.
C. ON ENG2 PUSHBUTTON SWITCH (7) :
- FAULT LEGEND ON,
- ON LEGEND ON.
8. WARNINGS REMAINS ON.
9. APPLY AIR PRESSURE TO SYSTEM OR RUN-UP
ENGINE.
10.ON PANEL 24VU,
A. PRESS ENG1 PUSHBUTTON SWITCH (6):
- FAULT LEGEND OFF,
- ON LEGEND ON.
B. PRESS AFR AIR BLEED PUSHBUTTON
SWITCH (2) :
- FAULT LEGEND OFF,
- OFF LEGEND OFF.
C. RESET ENG2 PUSHBUTTON SWITCH (7):
- FAULT LEGEND OFF,
- ON LEGEND ON.
D. RESET AIR FRAME PUSHBUTTON SWITCH(3):
- FAULT LEGEND OFF,
- ON LEGEND ON.
11.WARNINGS DESAPPEAR.
12.ON PANEL 24VU,
A. RELEASE AIR FRAME, ENG1 AND ENG2
PUSHBUTTON SWITCHES (3), (6) AND (7):
- FAULT LEGENDS OFF,
*** CONTINUED ***
AH

30-21-00
OPT 10000-004
2-400 PAGE
10
DEC 01/14

30-21-00

OPERATIONAL TEST OF
ENGINE AIR INTAKE DEICING SYSTEM

OPT 10000-004
11

DEC14

- ON LEGENDS OFF.


B. RELEASE MODE SEL/AUTO PUSHBUTTON
SWITCHES (5) :
- FAULT LEGENDS OFF,
- MAN LEGENDS OFF.
13.ON PANEL 402VU, CHECK THAT DE ICING
ANNUNCIATOR (4) IS OFF.
14.PLACE THE CONDITION LEVER (CLA) ON FUEL SO
POSITION.
15.ON PANEL 702VU,
PLACE WEIGHT ON WHEELS SWITCH ON NORM
POSITION.
16.DISCONNECT GROUND AIR PRESSURIZATION UNIT
OR SHUT OFF ENGINE.
NOTE : A. REPEAT TEST WITH GROUND AIR
PRESSURIZATION UNIT CONNECTED
TO REGULATOR AND SHUT OFF VALVE
ON RIGHT ENGINE.
IN ABOVE PROCEDURE, REPLACE
PUSHBUTTON SWITCHES :
ENG1 (6) BY ENG2 (7)
ENG2 (7) BY ENG1 (6)
B. BY MEAN OF THE PROCEDURE BELLOW
MAKE SURE THAT THE FOLLOWING
FAILURE ARE MEMORIZED IN BOOTS
MFC MAINTENANCE MEMORY :
- LEFT ENGINE BOOT A FAULT
- RIGHT ENGINE BOOT A FAULT
- LEFT ENGINE BOOT B FAULT
- RIGHT ENGINE BOOT B FAULT

*** CONTINUED ***


AH

30-21-00
OPT 10000-004
2-400 PAGE
11
DEC 01/14

30-21-00

OPERATIONAL TEST OF
ENGINE AIR INTAKE DEICING SYSTEM

010

OPT 10000-004
12

DEC14

_________________________________
READING
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RDG-10000

011

_________________________________
ERASURE
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RON-10000

012

DE-ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


______________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

013

________
CLOSE-UP
1. MAKE CERTAIN THAT WORKING AREA IS CLEAN AND
CLEAR OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
2. REMOVE ACCESS PLATFORMS AFTER HAVING CLOSED
ENGINE COWLS 435AL AND 445AL.

014

___________________________________
CLOSING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000
*****

AH

E N D

O F

T E X T

*****

30-21-00
OPT 10000-004
2-400 PAGE
12
DEC 01/14

30-21-00
13

AH

CONTROLS AND INDICATING


WING/ENGINE DE ICING

OPT 10000-004
DEC14

30-21-00
OPT 10000-004

2-400

PAGE
13
DEC 01/14

30-21-00
14

AH

TEST COUPLING - PRESSURE


REGULATOR AND SHUT-OFF
VALVE

OPT 10000-004
DEC14

30-21-00
OPT 10000-004

2-400

PAGE
14
DEC 01/14

30-21-00
15

AH

CHECK OF REGULATOR VALVE


AND DUAL DISTRIBUTOR
VALVES AIR LEAKAGE.

OPT 10000-004
DEC14

30-21-00
OPT 10000-004

2-400

PAGE
15
DEC 01/14

30-21-00

OPERATIONAL TEST OF
ENGINE AIR INTAKE DEICING SYSTEM

OPT 10000-005
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 210
435
445
: 435AL 445AL

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

GSE

: 01 ACCESS PLATFORM
01 COMPRESSOR

_________
MAN-HOURS

PUBLICATION
___________
JIC
JIC
JIC
JIC
JIC

: PRINCIPLE OF CDS USE


(DISPLAY UNITS
EXPLORATION)
: OPENING AND CLOSING OF
HINGED ENGINE COWLS
: READING OF MFC
MAINTENANCE MEMORY
: ERASURE OF MFC
MAINTENANCE MEMORY
: DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY

AH

31-63-00-PRO-10000
54-00-00-OAC-10000
45-13-00-RDG-10000
45-13-00-RON-10000
24-46-00-EAD-10000

30-21-00
OPT 10000-005
2-400 PAGE
1
DEC 01/14

30-21-00

OPERATIONAL TEST OF
ENGINE AIR INTAKE DEICING SYSTEM

001

OPT 10000-005
2

DEC14

PRINCIPLE OF CDS USE (DISPLAY UNITS


___________________________________
EXPLORATION)
____________
(TO USE ONLY IF NEEDED)
_______________________
SEE JOB INSTRUCTION CARD
316300-PRO-10000
NOTE: PROCEDURE TO USE ONLY IF NEEDED.
THIS PROCEDURE DESCRIBES LOCATION AND
MANAGEMENT OF THE DIFFERENT DISPLAY
WINDOWS PROVIDED BY THE THREE FORMATS
(PFD, EWD, MFD) PROPOSED ON THE FIVE
DISPLAY UNITS (DU).

002

___________
PREPARATION
1. INSTALL ACCESS PLATFORM SO AS TO HAVE ACCESS
TO FOLLOWING EQUIPMENTS :
- ON ENGINE L AND R
. VALVE SHUT OFF REGULATOR
. DUAL DISTRIBUTOR VALVE
2. OPEN ENGINE PANELS 435AL (455AL).
3. BY MEANS OF THE BELOW PROCEDURE CHECK IF
SYSTEM BOOTS FAILURE IS MEMORIZED IN
MFC MAINTENANCE MEMORY.

003

___________________________________
OPENING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000

004

_________________________________
READING
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RDG-10000

*** CONTINUED ***


AH

30-21-00
OPT 10000-005
2-400 PAGE
2
DEC 01/14

30-21-00

OPERATIONAL TEST OF
ENGINE AIR INTAKE DEICING SYSTEM

005

OPT 10000-005
3

DEC14

_________________________________
ERASURE
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RON-10000
NOTE:THIS TASK MUST BE PERFORMED ONLY IF FAULTS
RELATIVE TO THE SYSTEM TO BE CHECKED HAVE
BEEN RECORDED BY THE MFC MAINTENANCE
MEMORY.

006

ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


___________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

007

OPERATIONAL TEST OF ENGINE AIR INTAKE


_____________________________________
DE-ICING SYSTEM (PART 1/3)
__________________________
REF. FIG. 301100-OPT-00100, 301100-OPT-00110,
301100-CHK-00110.
TO PERFORM TEST, CONNECT GROUND AIR PRESSURIZATION UNIT 4 BARS (58 PSI) (60 L/SEC)
TO LEFT REGULATOR VALVE TEST PORT 1.
NOTE :THIS TEST CAN BE PERFORMED ALSO WITH 1
ROTATING ENGINE.
ENGINES COWLS CLOSED. AFTER AN ENGINE
REPLACEMENT,PERFORM TEST DURING ENGINE
ADJUSTMENT AT RUN-UP.
1. ON PANEL 702VU,
PLACE SWITCH WEIGHT ON WHEELS IN FLT
POSITION.
2. ON PANEL 24VU,
A. CHECK THAT AFR AIR BLEED PUSHBUTTON
SWITCH (2) IS PRESSED (IN):
- FAULT LEGEND OFF,
*** CONTINUED ***
AH

30-21-00
OPT 10000-005
2-400 PAGE
3
DEC 01/14

30-21-00

OPERATIONAL TEST OF
ENGINE AIR INTAKE DEICING SYSTEM

OPT 10000-005
4

DEC14

- OFF LEGEND OFF.


B. PRESS MODE SEL/AUTO PUSHBUTTON
SWITCH (5) :
- FAULT LEGEND OFF,
- MAN LEGEND ON.
- ON EWD, IN ALERT WINDOW,
A-ICING AUTO MESSAGE APPEARS.
C. CHECK THAT MODE SEL PUSHBUTTON
SWITCH (1) IS RELEASED (OUT):
- SLOW LEGEND OFF.
D. PRESS ENG1 AND ENG2 PUSHBUTTON
SWITCHES (6) AND (7) :
- FAULT LEGENDS OFF,
- ON LEGENDS ON.
ON MFD, IN TEMPORARY SELECTION WINDOW,
CYAN 1 ENG 2 MESSAGE IS DISPLAYED.
3. WAIT DE ICING CYCLE I.E. 60 SECONDS :
- NO WARNING MUST APPEAR.
4. ON PANEL 24VU,
PRESS MODE SEL PUSHBUTTON SWITCH (1):
- SLOW LEGEND ON.
5. WAIT COMPLETE DE ICING CYCLE I.E. 180
SECONDS :
- NO WARNING MUST APPEAR.
NOTE: PERFORM THIS TEST ONLY WHEN THIS TEST IS
PERFORMED WITH A COMPRESSOR.
CHECK MANUALLY AND AURALLY FOR AIR
LEAKAGE OF REGULATOR AND SHUTOFF VALVES
(5) AND (8)AT LEVEL OF REGULATION BELLOWS
(12) LOCATED UNDER THE VALVES,AND FOR AIR
LEAKAGE OF DUAL DISTRIBUTOR VALVES (6)
AND (7) AND AIR JET PUMPS (13) LOCATED AT
THE UPPER END OF THE VALVES.
DURING THE DE ICERS BOOTS A AND B INFLATE
CHECK VISUALY THE ALL DE ICERS SURFACE
THE ABSENCE OF FLATULENCE OR UNGLUING.
*** CONTINUED ***
AH

30-21-00
OPT 10000-005
2-400 PAGE
4
DEC 01/14

30-21-00

OPERATIONAL TEST OF
ENGINE AIR INTAKE DEICING SYSTEM

OPT 10000-005
5

DEC14

6. ON PANEL 24VU,
RELEASE MODE SEL PUSHBUTTON SWITCH (1):
- SLOW LEGEND OFF.
7. ON PANEL 25VU,
RELEASE (7UA1) MFC/1A AND (6UA1) MFC/1B
PUSHBUTTON SWITCHES (8) AND (9) :
- FAULT LEGEND OFF,
- OFF LEGEND ON.
8. WAIT DE ICING CYCLE I.E. 60 SECONDS. NO
WARNING MUST APPEAR.
9. ON PANEL 24VU,
PRESS MODE SEL PUSHBUTTON SWITCH (1):
- SLOW LEGEND ON.
10.WAIT DE ICING CYCLE I.E. 180 SECONDS.
NO WARNING MUST APPEAR.
11.ON PANEL 25VU,
A. PRESS (7UA1) MFC/1A AND (6UA1) MFC/1B
PUSHBUTTON SWITCHES (8) AND (9) :
- FAULT LEGENDS OFF,
- OFF LEGENDS OFF.
B. WAIT DE ICING CYCLE I.E. 180 SECONDS.
C. RELEASE (7UA2) MFC/2A AND (6UA2)
MFC/2B PUSHBUTTON SWITCHES (10) AND
(11).
- FAULT LEGENDS OFF,
- OFF LEGENDS ON.
12.WAIT DE ICING CYCLE I.E. 180 SECONDS.
NO WARNING MUST APPEAR.
13.ON PANEL 24VU,
RELEASE MODE SEL PUSHBUTTON SWITCH (1):
- SLOW LEGEND OFF.
14.WAIT DE ICING CYCLE I.E. 60 SECONDS.
*** CONTINUED ***
AH

30-21-00
OPT 10000-005
2-400 PAGE
5
DEC 01/14

30-21-00

OPERATIONAL TEST OF
ENGINE AIR INTAKE DEICING SYSTEM

OPT 10000-005
6

DEC14

NO WARNING MUST APPEAR.


15.ON PANEL 25VU,
PRESS (7UA2) MFC/2A AND (6UA2) MFC/2B
PUSHBUTTON SWITCHES (10) AND (11) :
- FAULT LEGENDS OFF,
- OFF LEGENDS OFF.
16.USING BELOW READING OF MFC MAINTENANCE
MEMORY PROCEDURE MAKE SURE THAT FAILURE ARE
NOT MEMORIZED IN BOOTS MFC MAINTENANCE
MEMORY :
- LEFT ENGINE BOOT A FAULT
- RIGHT ENGINE BOOT A FAULT
- LEFT ENGINE BOOT B FAULT
- RIGHT ENGINE BOOT B FAULT
NOTE: FOR THIS MEMORY CHECK, WOW SWITCH HAVE TO
BE RETURNED IN NORM POSITION.
008

_________________________________
READING
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RDG-10000

009

OPERATIONAL TEST OF ENGINE AIR INTAKE


_____________________________________
DE-ICING SYSTEM (PART 2/3)
__________________________
REF. FIG. 301100-OPT-00100, 301100-OPT-00110
301100-CHK-00110.
NOTE: DURING THE TEST CHECK VISUALLY ALL
DE ICERS SURFACE THE ABSENCE OF BURN
MARK, INFLATION AND UNGLUING.
1.ON PANEL 702VU,
PLACE SWITCH WEIGHT ON WHEELS IN FLT
POSITION.
2. PLACE THE CONDITION LEVER (CLA) ON AUTO
POSITION.
*** CONTINUED ***
AH

30-21-00
OPT 10000-005
2-400 PAGE
6
DEC 01/14

OPERATIONAL TEST OF
ENGINE AIR INTAKE DEICING SYSTEM

30-21-00

OPT 10000-005
7

DEC14

3. ON COMPRESSOR OR ON ENGINE SHUT DOWN AIR


SUPPLY PRESSURE SYSTEM ALLOW TO PRESSURE
DROP.
4. ON PANEL 24VU,
ON AFR AIR BLEED PUSHBUTTON SWITCH (2):
- FAULT LEGEND ON,
- OFF LEGEND OFF.
5. FOLLOWING WARNINGS APPEAR :
- ON EWD, IN ALERT WINDOW, A-ICING BLEED
MESSAGE IS DISPLAYED.
- MASTER CAUTION ANNUNCIATORS COME ON,
- SINGLE CHIME SOUNDS.
6. ON PANEL 24VU,
ON ENG1 AND ENG2 PUSHBUTTON SWITCHES
(6) AND (7) :
- FAULT LEGEND LIGHT FLASHES EVERY 2,5S
AT THEORICAL CYCLE INFLATING OF BOOTS A
AND B,
- ON LEGEND ON.
7. ON PANEL 25VU, MAKE THE FOLLOWING
OPERATIONS :
- RELEASE (7UA1) MFC/1A PUSHBUTTON SWITCH
(8),
- WAIT DE ICING CYCLE I.E. 60 SECONDS,
- PRESS (7UA1) MFC/1A PUSHBUTTON SWITCH
(8),
- RELEASE (7UA2) MFC/2A PUSHBUTTON SWITCH
(10),
- WAIT DE ICING CYCLE I.E. 60 SECONDS,
- PRESS (7UA2) MFC/2A PUSHBUTTON SWITCH
(10).
8. DURING ABOVE OPERATIONS, WARNINGS REMAINS
ON.
9. ON PANEL 24VU,
*** CONTINUED ***
AH

30-21-00
OPT 10000-005
2-400 PAGE
7
DEC 01/14

30-21-00

OPERATIONAL TEST OF
ENGINE AIR INTAKE DEICING SYSTEM

OPT 10000-005
8

DEC14

A. RELEASE AFR AIR BLEED PUSHBUTTON


SWITCH (2) :
- FAULT LEGEND OFF,
- OFF LEGEND ON.
B. ON ENG1 AND ENG2 PUSHBUTTON
SWITCHES (6) AND (7) :
- FAULT LEGENDS ON,
- ON LEGENDS ON.
10.WARNINGS REMAINS ON.
11.ON PANEL 25VU, MAKE THE FOLLOWING
OPERATIONS:
- RELEASE (7UA1) MFC/1A PUSHBUTTON SWITCH
(8),
- WAIT DE ICING CYCLE I.E. 60 SECONDS,
- PRESS (7UA1) MFC/1A PUSHBUTTON SWITCH
(8),
- RELEASE (6UA1) MFC/1B PUSHBUTTON SWITCH
(9),
- WAIT DE ICING CYCLE I.E. 60 SECONDS,
- PRESS (6UA1) MFC/1B PUSHBUTTON SWITCH
(9),
- WAIT DE ICING CYCLE I.E. 60 SECONDS,
- RELEASE (7UA2) MFC/2A PUSHBUTTON SWITCH
(10),
- WAIT DE ICING CYCLE I.E. 60 SECONDS,
- PRESS (7UA2) MFC/2A PUSHBUTTON SWITCH
(10).
- RELEASE (6UA2) MFC/2B PUSHBUTTON SWITCH
(11),
- WAIT DE ICING CYCLE I.E. 60 SECONDS,
- PRESS (6UA2) MFC/2B PUSHBUTTON SWITCH
(11).
12.DURING ABOVE OPERATIONS, WARNINGS REMAINS
ON.
13.ON PANEL 24VU,
A. PRESS AFR AIR BLEED PUSHBUTTON
*** CONTINUED ***
AH

30-21-00
OPT 10000-005
2-400 PAGE
8
DEC 01/14

30-21-00

OPERATIONAL TEST OF
ENGINE AIR INTAKE DEICING SYSTEM

OPT 10000-005
9

DEC14

SWITCH (2) :
- FAULT LEGEND ON,
- OFF LEGEND OFF.
B. RESET ENG1 AND ENG2 PUSHBUTTON
SWITCHES (6) AND (7) :
- FAULT LEGEND LIGHT FLASHES EVERY 2,5S
AT THEORICAL CYCLE INFLATING OF BOOTS
A AND B,
- ON LEGENDS ON.
ON MFD, IN TEMPORARY SELECTION WINDOW,
THE SAME LOGIC IS APPLICATED WITH AMBER
1 ENG 2 MESSAGE.
14.APPLY AIR PRESSURE TO SYSTEM OR RUN-UP
ENGINE.
15.WARNINGS DESAPPEAR.
16.ON PANEL 24VU,
A. ON AFR AIR BLEED PUSHBUTTON SWITCH (2):
- FAULT LEGEND OFF,
- OFF LEGEND OFF.
B. ON ENG1 AND ENG2 PUSHBUTTON
SWITCHES (6) AND (7) :
- FAULT LEGENDS OFF,
- ON LEGENDS ON.
ON MFD, IN TEMPORARY SELECTION WINDOW,
CYAN 1 ENG 2 MESSAGE IS DISPLAYED.
17.ON PANEL 702VU,
PLACE WEIGHT ON WEELS SWITCH ON NORM.
010

OPERATIONAL TEST OF ENGINE AIR INTAKE


_____________________________________
DE-ICING SYSTEM (PART 3/3)
__________________________
REF. FIG. 301100-OPT-00100, 301100-OPT-00110
301100-CHK-00110
1. ON PANEL 702VU,
PLACE WEIGHT ON WHEELS SWITCH ON FLT
*** CONTINUED ***
AH

30-21-00
OPT 10000-005
2-400 PAGE
9
DEC 01/14

30-21-00

OPERATIONAL TEST OF
ENGINE AIR INTAKE DEICING SYSTEM

OPT 10000-005
10

DEC14

POSITION.
2. ON PANEL 24VU,
PRESS AIR FRAME PUSHBUTTON SWITCH (3):
- FAULT LEGEND OFF,
- ON LEGEND ON.
ON MFD, IN TEMPORARY SELECTION WINDOW,
CYAN AIRFRAME MESSAGE IS DISPLAYED.
3. SHUTT DOWN AIR SUPPLY PRESSURE IN SYSTEM
OR SHUTT OF THE ENGINE, ALLOW TO PRESSURE
DROP.
4. A. ON PANEL 24VU,
RELEASE ENG1 PUSHBUTTON SWITCH (6):
. FAULT LEGEND OFF,
. ON LEGEND OFF.
ON MFD, IN TEMPORARY SELECTION WINDOW,
CYAN ENG 2 MESSAGE IS DISPLAYED.
B. ON PANEL 24VU,
ON ENG2 PUSHBUTTON SWITCH (7) :
. FAULT LIGHT 2,5S DURING INFLATING
OF LEFT ENGINE BOOTS A AND B,
. ON LEGEND ON.
ON MFD, IN TEMPORARY SELECTION WINDOW,
THE SAME LOGIC IS APPLICATED WITH AMBER
ENG2 MESSAGE.
C. ON PANEL 24VU,
ON AFR AIR BLEED PUSHBUTTON SWITCH (2):
. FAULT LEGEND ON,
. OFF LEGEND OFF.
5. FOLLOWINGS WARNINGS APPEAR :
- ON EWD, IN ALERT WINDOW, A-ICING BLEED
MESSAGE IS DISPLAYED.
- MASTER CAUTION ANNUNCIATORS COME ON,
- SINGLE CHIME SOUNDS.
6. A. ON PANEL 24VU,
RELEASE AFR AIR BLEED PUSHBUTTON
SWITCH (2) :
*** CONTINUED ***
AH

30-21-00
OPT 10000-005
2-400 PAGE
10
DEC 01/14

30-21-00

OPERATIONAL TEST OF
ENGINE AIR INTAKE DEICING SYSTEM

OPT 10000-005
11

DEC14

- FAULT LEGEND OFF,


- OFF LEGEND ON.
B. ON PANEL 24VU,
ON AIR FRAME PUSHBUTTON SWITCH (3):
- FAULT LEGEND ON,
- ON LEGEND ON.
ON MFD, IN TEMPORARY SELECTION WINDOW,
AMBER AIRFRAME MESSAGE IS DISPLAYED.
C. ON PANEL 24VU,
ON ENG2 PUSHBUTTON SWITCH (7) :
- FAULT LEGEND ON,
- ON LEGEND ON.
ON MFD, IN TEMPORARY SELECTION WINDOW,
AMBER ENG 2 MESSAGE IS DISPLAYED.
7. WARNINGS REMAINS ON.
8. APPLY AIR PRESSURE TO SYSTEM OR RUN-UP
ENGINE.
9.A. ON PANEL 24VU,
PRESS ENG1 PUSHBUTTON SWITCH (6):
- FAULT LEGEND OFF,
- ON LEGEND ON.
ON MFD, IN TEMPORARY SELECTION WINDOW,
CYAN 1 WITH AMBER ENG 2 MESSAGE IS
DISPLAYED.
B. ON PANEL 24VU,
PRESS AFR AIR BLEED PUSHBUTTON
SWITCH (2) :
- FAULT LEGEND OFF,
- OFF LEGEND OFF.
C. ON PANEL 24VU,
RESET ENG2 PUSHBUTTON SWITCH (7):
- FAULT LEGEND OFF,
- ON LEGEND ON.
ON MFD, IN TEMPORARY SELECTION WINDOW,
CYAN 1 ENG 2 MESSAGE IS DISPLAYED.
D. ON PANEL 24VU,
RESET AIR FRAME PUSHBUTTON SWITCH (3):
- FAULT LEGEND OFF,
*** CONTINUED ***
AH

30-21-00
OPT 10000-005
2-400 PAGE
11
DEC 01/14

OPERATIONAL TEST OF
ENGINE AIR INTAKE DEICING SYSTEM

30-21-00

OPT 10000-005
12

DEC14

- ON LEGEND ON.


ON MFD, IN TEMPORARY SELECTION WINDOW,
CYAN AIRFRAME MESSAGE IS DISPLAYED.
10.WARNINGS DESAPPEAR.
11.A. ON PANEL 24VU,
RELEASE AIR FRAME, ENG1 AND ENG2
PUSHBUTTON SWITCHES (3), (6) AND (7):
- FAULT LEGENDS OFF,
- ON LEGENDS OFF.
ON MFD, IN TEMPORARY SELECTION WINDOW,
AIRFRAME AND 1 ENG 2 MESSAGE
DISAPPEAR.
B. RELEASE MODE SEL/AUTO PUSHBUTTON
SWITCHES (5) :
- FAULT LEGENDS OFF,
- MAN LEGENDS OFF.
ON EWD, IN ALERT WINDOW, A-ICING AUTO
MESSAGE DISAPPEARS.
12.PLACE THE CONDITION LEVER (CLA) ON FUEL SO
POSITION.
13.ON PANEL 702VU,
PLACE WEIGHT ON WHEELS SWITCH ON NORM
POSITION.
14.DISCONNECT GROUND AIR PRESSURIZATION UNIT
OR SHUT OFF ENGINE.
NOTE : A. REPEAT TEST WITH GROUND AIR
PRESSURIZATION UNIT CONNECTED
TO REGULATOR AND SHUT OFF VALVE
ON RIGHT ENGINE.
IN ABOVE PROCEDURE, REPLACE
PUSHBUTTON SWITCHES:
ENG1 (6) BY ENG2 (7)
ENG2 (7) BY ENG1 (6)
*** CONTINUED ***
AH

30-21-00
OPT 10000-005
2-400 PAGE
12
DEC 01/14

30-21-00

OPERATIONAL TEST OF
ENGINE AIR INTAKE DEICING SYSTEM

OPT 10000-005
13

DEC14

B. BY MEAN OF THE PROCEDURE BELLOW


MAKE SURE THAT THE FOLLOWING
FAILURE ARE MEMORIZES IN BOOTS
MFC MAINTENANCE MEMORY:
- LEFT ENGINE BOOT A FAULT
- RIGHT ENGINE BOOT A FAULT
- LEFT ENGINE BOOT B FAULT
- RIGHT ENGINE BOOT B FAULT
011

_________________________________
READING
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RDG-10000

012

_________________________________
ERASURE
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RON-10000

013

DE-ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


______________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

014

________
CLOSE-UP
1. MAKE CERTAIN THAT WORKING AREA IS CLEAN AND
CLEAR OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
2. REMOVE ACCESS PLATFORMS AFTER HAVING CLOSED
ENGINE COWLS 435AL AND 445AL.

015

___________________________________
CLOSING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000
*****

AH

E N D

O F

T E X T

*****

30-21-00
OPT 10000-005
2-400 PAGE
13
DEC 01/14

30-21-00
14

AH

CONTROLS AND INDICATING


WING/ENGINE DE ICING

OPT 10000-005
DEC14

30-21-00
OPT 10000-005

2-400

PAGE
14
DEC 01/14

30-21-00
15

AH

TEST COUPLING - PRESSURE


REGULATOR AND SHUT-OFF
VALVE

OPT 10000-005
DEC14

30-21-00
OPT 10000-005

2-400

PAGE
15
DEC 01/14

30-21-00
16

AH

CHECK OF REGULATOR VALVE


AND DUAL DISTRIBUTOR
VALVES AIR LEAKAGE.

OPT 10000-005
DEC14

30-21-00
OPT 10000-005

2-400

PAGE
16
DEC 01/14

30-21-61

REMOVAL/INSTALLATION OF
ENGINE DUAL DISTRIBUTOR
VALVES

RAI 10000-001
1

APR05

ZONING DATA
___________
ZONE
ACCESS

: 430
440
: 435AL 436AR 445AL 446AR

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

GSE

: 01 ACCESS PLATFORM

SPARE

: 02 DUAL DISTRIBUTOR VALVE


04 UNION
02 UNION

302160-06-070
302160-06-030
302160-06-050

EXPENDABLE

: 04 SEAL
02 SEAL
06 NUT

302160-06-040
302160-06-060
302160-06-020

BULK MATERIAL : GREASE

_________
MAN-HOURS

04-020

PUBLICATION
___________
JIC
JIC

: OPENING AND CLOSING OF


HINGED ENGINE COWLS
: OPERATIONAL TEST OF
ENGINE AIR INTAKE
ANTI-ICING SYSTEM

AH

54-00-00-OAC-10000
30-21-00-OPT-10000

30-21-61
RAI 10000-001
2-400 PAGE
1
APR 01/05

30-21-61

REMOVAL/INSTALLATION OF
ENGINE DUAL DISTRIBUTOR
VALVES

001

RAI 10000-001
2

APR05

___________
PREPARATION
1. ON PANEL 122VU, OPEN SAFETY AND TAG THE FOLLOWING CIRCUIT BREAKERS:
2DM ANTI/DE ICING/ENG2 & AFR BOOTS B/NORM
SPLY & V HTG CTL
3DM ANTI/DE ICING/ENG1 & AFR BOOTS A/SPLY
52DM ANTI/DE ICING/ENG2 & AFR BOOTS B EMER
SPLY
2. INSTALL PLATFORM TO GAIN ACCESS TO DUAL
DISTRIBUTOR VALVE 3DN (4DN).
3. OPEN ENGINE COWLS 435AL (445AL) AND 436AR
(446AR).

002

_______________________
OPENING
OF HINGED COWLS
SEE JOB INSTRUCTION CARD
540000-OAC-10000

003

________________________________________
REMOVAL
OF ENGINE DUAL DISTRIBUTOR VALVE
REF. FIG. 302161-RAI-00110
1. DISCONNECT ELECTRICAL CONNECTORS (1) AND (2)
ON DUAL DISTRIBUTOR VALVE (3).
2. DISCONNECT DISTRIBUTION LINES (4).
3. REMOVE SUPPLY LINE (5).
4. REMOVE BOLTS (6) AND NUTS (7).
DISCARD NUTS (7).
5. REMOVE DUAL DISTRIBUTOR VALVE (3).
6. REMOVE COUPLINGS (8) AND O-RINGS (9).
DISCARD O-RINGS (9).
*** CONTINUED ***
AH

30-21-61
RAI 10000-001
2-400 PAGE
2
APR 01/05

30-21-61

REMOVAL/INSTALLATION OF
ENGINE DUAL DISTRIBUTOR
VALVES

RAI 10000-001
3

APR05

7. REMOVE COUPLING (10) AND O-RING (11).


DISCARD O-RING (11).
8. INSTALL BLANKING CAPS AND PLUGS ON LINES AND
ELECTRICAL CONNECTORS.
004

_____________________________________________
INSTALLATION
OF ENGINE DUAL DISTRIBUTOR VALVE
REF. FIG. 302161-RAI-00110
1. INSTALL COUPLING (10) AND O-RING (11).
COAT THREADED PARTS OF COUPLING WITH GREASE
04-020. TIGHTEN (TORQUE VALUE 7.29 TO 7.40
M.DAN/645.1 TO 654.8 LBF.IN).
2. INSTALL COUPLINGS (8) AND O-RINGS (9).
COAT THREADED PARTS OF COUPLINGS WITH
GREASE 04-020. TIGHTEN (TORQUE VALUE 5.03 TO
5.14 M.DAN/445.1 TO 454.8 LBF.IN).
3. CLEAN AND INSPECT COMPONENT INTERFACE AND/OR
ADJACENT AREA.
4. REMOVE BLANKING CAPS.
5. POSITION DUAL DISTRIBUTOR VALVE (3).
POSITION BOLTS (6) AND NUTS (7). TIGHTEN.
6. INSTALL DISTRIBUTION LINES (4). TIGHTEN.
7. INSTALL SUPPLY LINE (5). TIGHTEN (TORQUE
VALUE 9.7 TO 10.7 M.DAN/858.4 TO 946.8
LBF.IN).
8. CONNECT ELECTRICAL CONNECTORS (1) AND (2).

005

OPERATIONAL TEST OF ENGINE AIR INTAKE ANTI___________________________________________


ICING SYSTEM.
_____________
SEE JOB INSTRUCTION CARD
302100-OPT-10000
*** CONTINUED ***
AH

30-21-61
RAI 10000-001
2-400 PAGE
3
APR 01/05

30-21-61

REMOVAL/INSTALLATION OF
ENGINE DUAL DISTRIBUTOR
VALVES

006

RAI 10000-001
4

APR05

________
CLOSE-UP
1. MAKE CERTAIN THAT WORKING AREA IS CLEAN
AND CLEAR OF TOOLS AND MISCELLANEOUS ITEMS
OF EQUIPMENT.
2. CLOSE ENGINE COWLS 435AL (445AL) AND 436AR
(446AR).
3. REMOVE ACCESS PLATFORM.
4. CLOSE CIRCUIT BREAKERS MENTIONED ABOVE.

007

______________________________
CLOSING
OF HINGED ENGINE COWLS
SEE JOB INSTRUCTION CARD
540000-OAC-10000
*****

AH

E N D

O F

T E X T

*****

30-21-61
RAI 10000-001
2-400 PAGE
4
APR 01/05

30-21-61
5

AH

REMOVAL AND INSTALLATION


OF ENGINE DUAL
DISTRIBUTOR VALVES

RAI 10000-001
APR05

30-21-61
RAI 10000-001

2-400

PAGE
5
APR 01/05

30-21-64

REMOVAL/INSTALLATION OF
PRESSURE SWITCH

RAI 10000-001
1

APR05

ZONING DATA
___________
ZONE
ACCESS

: 435
445
: 435AL 445AL

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

GSE

: 01 ACCESS PLATFORM

SPARE

: 04 PRESSURE SWITCH

302160-10-70

EXPENDABLE

: 04 SEAL

302160-10-60

BULK MATERIAL : GREASE


LOCKWIRE

_________
MAN-HOURS

04-004

PUBLICATION
___________
JIC
JIC

: OPENING AND CLOSING OF


HINGED ENGINE COWLS
: OPERATIONAL TEST OF
ENGINE AIR INTAKE
ANTI-ICING SYSTEM

AH

54-00-00-OAC-10000
30-21-00-OPT-10000

30-21-64
RAI 10000-001
2-400 PAGE
1
APR 01/05

30-21-64

REMOVAL/INSTALLATION OF
PRESSURE SWITCH

001

RAI 10000-001
2

APR05

___________
PREPARATION
1. INSTALL ACCESS PLATFORM, TO GAIN ACCESS TO
PRESSURE SWITCHES LOCATED ON LH SIDE OF
ENGINES.
2. OPEN ENGINE COWLS 435AL AND 445AL.
NOTE : REMOVAL/INSTALLATION GIVEN BELOW CAN
BE APPLIED INDIFFERENTLY TO PRESSURE
SWITCHES 11DN AND 13DN LOCATED ON
LEFT ENGINE AND PRESSURE SWITCHES
14DN AND 16DN LOCATED ON RIGHT
ENGINE.

002

___________________________________
OPENING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000

003

__________________________
REMOVAL
OF PRESSURE SWITCH
REF. FIG. 302164-RAI-00100
1. DISCONNECT ELECTRICAL CONNECTOR (1).
2. CUT AND REMOVE LOCKWIRE, LOOSEN AND REMOVE
PRESSURE SWITCH (2).
3. REMOVE AND DISCARD SEAL (3).
4. INSTALL BLANKING PLUGS ON :
- ELECTRICAL CONNECTOR,
- PRESSURE SWITCH,
- UNION (4).

004

________________________
INSTALLATION
OF PRESSURE
REF. FIG. 302164-RAI-00100
1. CLEAN AND INSPECT COMPONENT INSTALLATION
*** CONTINUED ***
AH

30-21-64
RAI 10000-001
2-400 PAGE
2
APR 01/05

30-21-64

REMOVAL/INSTALLATION OF
PRESSURE SWITCH

RAI 10000-001
3

APR05

AREA.
2. REMOVE BLANKS.
3. INSTALL NEW SEAL (3) ON PRESSURE SWITCH
(2). LUBRICATE PRESSURE SWITCH THREADS WITH
GREASE 04-004.
4. INSTALL PRESSURE SWITCH (2) ON COUPLING (4)
(TORQUE VALUE 1,6 TO 2 M.DAN/141,6 TO
177 LBF.IN). WIRELOCK.
5. CONNECT ELECTRICAL CONNECTOR (1).
005

OPERATIONAL TEST OF ENGINE AIR INTAKE ANTI___________________________________________


ICING SYSTEM.
_____________
SEE JOB INSTRUCTION CARD
302100-OPT-10000

006

________
CLOSE-UP
1. MAKE CERTAIN THAT WORKING AREA IS CLEAN AND
CLEAR OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
2. CLOSE ENGINE COWLS 435AL AND 445AL.
3. REMOVE ACCESS PLATFORM.

007

___________________________________
CLOSING
OF LEFT LATERAL HINGED COWL
SEE JOB INSTRUCTION CARD
540000-OAC-10000
*****

AH

E N D

O F

T E X T

*****

30-21-64
RAI 10000-001
2-400 PAGE
3
APR 01/05

30-21-64
4

AH

REMOVAL/INSTALLATION
OF PRESSURE SWITCH

RAI 10000-001
APR05

30-21-64
RAI 10000-001

2-400

PAGE
4
APR 01/05

30-21-65

REMOVAL/INSTALLATION OF
ENGINE AIR INTAKE
DE-ICER

RAI 10000-001
1

APR05

ZONING DATA
___________

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

AH

___
MEN

_________
MAN-HOURS

30-21-65
RAI 10000-001
2-400 PAGE
1
APR 01/05

30-21-65

REMOVAL/INSTALLATION OF
ENGINE AIR INTAKE
DE-ICER

001

RAI 10000-001
2

APR05

REMOVAL/INSTALLATION OF ENGINE AIR INTAKE


_________________________________________
DE-ICER.
________
FOR REMOVAL/INSTALLATION OF THE ENGINE AIRINTAKE DE-ICER (5001DN) SEE CMM/M 71-61-61
AIR INTAKE LEADING EDGE ASSY
*****

AH

E N D

O F

T E X T

*****

30-21-65
RAI 10000-001
2-400 PAGE
2
APR 01/05

30-21-65

REMOVAL/INSTALLATION OF
ENGINE AIR INTAKE
DE-ICER

RAI 10000-002
1

DEC14

ZONING DATA
___________

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

AH

___
MEN

_________
MAN-HOURS

30-21-65
RAI 10000-002
2-400 PAGE
1
DEC 01/14

30-21-65

REMOVAL/INSTALLATION OF
ENGINE AIR INTAKE
DE-ICER

001

RAI 10000-002
2

DEC14

REMOVAL/INSTALLATION OF ENGINE AIR INTAKE


_________________________________________
DE-ICER.
________
FOR REMOVAL/INSTALLATION OF THE ENGINE AIRINTAKE DE-ICER (5001DN1, 5001DN2) SEE CMM/M
71-61-61
AIR INTAKE LEADING EDGE ASSY
*****

AH

E N D

O F

T E X T

*****

30-21-65
RAI 10000-002
2-400 PAGE
2
DEC 01/14

30-21-65

REMOVAL/INSTALLATION OF
ENGINE AIR INTAKE THROAT
DE-ICER

RAI 10010-001
1

APR05

ZONING DATA
___________

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

AH

___
MEN

_________
MAN-HOURS

30-21-65
RAI 10010-001
2-400 PAGE
1
APR 01/05

30-21-65

REMOVAL/INSTALLATION OF
ENGINE AIR INTAKE THROAT
DE-ICER

001

RAI 10010-001
2

APR05

REMOVAL/INSTALLATION OF ENGINE AIR INTAKE


_________________________________________
THROAT DE-ICERS.
________________
FOR REMOVAL/INSTALLATION OF THE ENGINE AIRINTAKE THROAT DE-ICERS (5003DN AND 5007DN) SEE
CMM/M 71-62-62
DUCT ASSY
*****

AH

E N D

O F

T E X T

*****

30-21-65
RAI 10010-001
2-400 PAGE
2
APR 01/05

30-21-65

REMOVAL/INSTALLATION OF
ENGINE AIR INTAKE THROAT
DE-ICER

RAI 10010-002
1

DEC14

ZONING DATA
___________

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

AH

___
MEN

_________
MAN-HOURS

30-21-65
RAI 10010-002
2-400 PAGE
1
DEC 01/14

30-21-65

REMOVAL/INSTALLATION OF
ENGINE AIR INTAKE THROAT
DE-ICER

001

RAI 10010-002
2

DEC14

REMOVAL/INSTALLATION OF ENGINE AIR INTAKE


_________________________________________
THROAT DE-ICER.
_______________
FOR REMOVAL/INSTALLATION OF THE ENGINE AIRINTAKE THROAT DE-ICER (5003DN1, 5003DN2) SEE
CMM/M 71-62-62
DUCT ASSY
*****

AH

E N D

O F

T E X T

*****

30-21-65
RAI 10010-002
2-400 PAGE
2
DEC 01/14

30-21-65

REMOVAL/INSTALLATION OF
OIL COOLER DE-ICER

RAI 10020-001
1

APR05

ZONING DATA
___________

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

AH

___
MEN

_________
MAN-HOURS

30-21-65
RAI 10020-001
2-400 PAGE
1
APR 01/05

30-21-65

REMOVAL/INSTALLATION OF
OIL COOLER DE-ICER

001

RAI 10020-001
2

APR05

___________________________________________
REMOVAL/INSTALLATION
OF OIL COOLER DE-ICER.
FOR REMOVAL/INSTALLATION OF THE OIL COOLER
DE-ICER (5005DN) SEE CMM/M 71-62-62
DUCT ASSY
*****

AH

E N D

O F

T E X T

*****

30-21-65
RAI 10020-001
2-400 PAGE
2
APR 01/05

30-21-65

REMOVAL/INSTALLATION OF
OIL COOLER DE-ICER

RAI 10020-002
1

DEC14

ZONING DATA
___________

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

AH

___
MEN

_________
MAN-HOURS

30-21-65
RAI 10020-002
2-400 PAGE
1
DEC 01/14

30-21-65

REMOVAL/INSTALLATION OF
OIL COOLER DE-ICER

001

RAI 10020-002
2

DEC14

___________________________________________
REMOVAL/INSTALLATION
OF OIL COOLER DE-ICER.
FOR REMOVAL/INSTALLATION OF THE OIL COOLER
DE-ICER (5005DN1, 5005DN2) SEE CMM/M 71-62-62
DUCT ASSY
*****

AH

E N D

O F

T E X T

*****

30-21-65
RAI 10020-002
2-400 PAGE
2
DEC 01/14

30-31-00

OPERATIONAL TEST OF
HEATING SYSTEM
INDICATING

OPT 10000-001
1

MAR12

ZONING DATA
___________
ZONE

: 113
210

114
211

212

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC

ELAPSED TIME

___
MEN

_________
MAN-HOURS
01

PUBLICATION
___________
JIC

: DC AND AC EXTERNAL POWER


SUPPLY

AH

24-40-00-EAD-10000

30-31-00
OPT 10000-001
2-400 PAGE
1
MAR 01/12

30-31-00

OPERATIONAL TEST OF
HEATING SYSTEM
INDICATING

001

OPT 10000-001
2

MAR12

___________________________________________
ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000

002

___________
PREPARATION
REF.FIG.303100-OPT-00100 (FIG.1)
REF.FIG.303100-OPT-00110 (FIG.2)
NOTE: IN ORDER TO SIMPLIFY THIS JIC THE THREE
SUBSYSTEMS (CAPT-F/O-STBY) HAVE BEEN
GROUPED. IN THIS WAY THE OPERATOR CAN MAKE REFERENCE TO ANY OF THE ABOVE MENTIONED GROUP INDEPENDENTLY
1. CAPT SUBSYSTEM:
ON PANEL 26VU (FIG.2-C) CHECK THAT
- TWO LEGENDS (PITOT AND STAT) OF PROBES
HTG/CAPT ANNUNCIATOR 63DA COME ON
- ALPHA LEGEND OF PROBES HTG/CAPT
ANNUNCIATOR 65DA COMES ON
- OFF LEGEND ON PROBES HTG/CAPT PUSHBUTTON
SWITCH 25DA (RELEASED) COMES ON
F/O SUBSYSTEM:
ON PANEL 26VU (FIG.2-C) CHECK THAT:
- TWO LEGENDS (PITOT AND STAT) OF PROBES
HTG/F/O ANNUNCIATOR 64DA COME ON
- ALPHA LEGEND OF PROBES HTG/F/O
ANNUNCIATOR 66DA COMES ON
- OFF LEGEND ON PROBES HTG/F/O PUSHBUTTON
SWITCH 22DA (RELEASED) COMES ON
STBY SUBSYSTEM:
ON PANEL 26VU (FIG.2-C) CHECK THAT
- TWO LEGENDS (PITOT AND STAT) OF PROBES
HTG/STBY ANNUNCIATOR 67DA COME ON
- OFF LEGEND ON PROBES HTG/STBY PUSHBUTTON
SWITCH 27DA (RELEASED) COMES ON
NOTE: TAT PROBE HEATING IS OPERATING ONLY IN
FLIGHT AND ALSO AN EVENTUAL FAILURE OF IT
*** CONTINUED ***
AH

30-31-00
OPT 10000-001
2-400 PAGE
2
MAR 01/12

30-31-00

OPERATIONAL TEST OF
HEATING SYSTEM
INDICATING

OPT 10000-001
3

MAR12

IS SHOWN ONLY IN FLIGHT, THEREFORE THE


INDICATING CONTROL IS OBTAINED AS FOLLOWS
ON PANEL 702VU (FIG.2-D)
PLACE NORM/FLT MODE SWITCH 57GB IN FLT
POSITION
CAPT SUBSYSTEM:
ON PANEL 26VU (FIG.2-C) CHECK THAT:
- TAT LEGEND OF ANNUNCIATOR 65DA
COMES ON TOO
- STAT LEGEND OF ANNUNCIATOR 63DA GOES OFF
F/O SUBSYSTEM:
ON PANEL 26VU (FIG.2-C) CHECK THAT:
- TAT LEGEND OF ANNUNCIATOR 66DA
COMES ON TOO
- STAT LEGEND OF ANNUNCIATOR 64DA GOES OFF
ON PANEL 702VU (FIG.2-D)
PLACE SWITCH 57GB IN NORM POSITION
2. REMOVE BLANKING CAPS FROM PROBES (FIG.1)
003

________________
OPERATIONAL
TEST
REF.FIG.303100-OPT-00110
1. ON PANEL 26VU(C)
CAPT SUBSYSTEM:
- PRESS PUSHBUTTON SWITCH 25DA
OFF LEGEND GOES OFF
- TWO LEGENDS (PITOT AND STAT) OF ANNUNCIATOR 63DA GO OFF
- ALPHA LEGEND OF ANNUNCIATOR 65DA GOES OFF
F/O SUBSYSTEM:
- PRESS PUSHBUTTON SWITCH 22DA
OFF LEGEND GOES OFF
- TWO LEGENDS (PITOT AND STAT) OF ANNUNCIATOR 64DA GO OFF
- ALPHA LEGEND OF ANNUNCIATOR 66DA GOES OFF
STBY SUBSYSTEM:
- PRESS PUSHBUTTON SWITCH 27DA
*** CONTINUED ***
AH

30-31-00
OPT 10000-001
2-400 PAGE
3
MAR 01/12

30-31-00

OPERATIONAL TEST OF
HEATING SYSTEM
INDICATING

OPT 10000-001
4

MAR12

OFF LEGEND GOES OFF


- TWO LEGENDS (PITOT AND STAT) OF ANNUNCIATOR 67DA GO OFF
NOTE: TAT PROBE HEATING IS OPERATING ONLY IN
FLIGHT AND ALSO AN EVENTUAL FAILURE OF
IT IS SHOWN ONLY IN FLIGHT; THEREFORE
THE INDICATING CONTROL IS OBTAINED AS
FOLLOWS:
ON PANEL 702VU(FIG.2-D)
PLACE NORM/FLT MODE SWITCH 57GB IN FLT
POSITION
CAPT SUBSYSTEM:
- RELEASED PUSHBUTTON SWITCH 25DA
- TAT LEGEND OF ANNUNCIATOR 65DA
COMES ON TOO
- STAT LEGEND OF ANNUNCIATOR 63DA
REMAINS OFF
F/O SUBSYSTEM:
- RELEASED PUSHBUTTON SWITCH 22DA
- TAT LEGEND OF ANNUNCIATOR 66DA
COMES ON TOO
- STAT LEGEND OF ANNUNCIATOR 64DA
REMAINS OFF
CAPT SUBSYSTEM:
- PRESS SWITCH 25DA
- TAT LEGEND GOES OFF
F/O SUBSYSTEM:
- PRESS SWITCH 22DA
- TAT LEGEND GOES OFF
004

________
CLOSE-UP
REF.FIG.303100-OPT-00100(FIG.1) AND 303100-OPT00110(FIG.2)
1. CAPT SUBSYSTEM:
- ON PANEL 26VU(FIG.2-C)
RELEASE PUSHBUTTON SWITCH 25DA
*** CONTINUED ***
AH

30-31-00
OPT 10000-001
2-400 PAGE
4
MAR 01/12

30-31-00

OPERATIONAL TEST OF
HEATING SYSTEM
INDICATING

OPT 10000-001
5

MAR12

F/O SUBSYSTEM:
- ON PANEL 26VU(FIG.2-C)
RELEASE PUSHBUTTON SWITCH 22DA
STBY SUBSYSTEM:
- ON PANEL 26VU(FIG.2-C)
RELEASE PUSHBUTTON SWITCH 27DA
- ON PANEL 702VU(FIG.2-D)
PLACE SWITCH 57GB IN NORM POSITION
2. WAIT UNTIL PROBES HAVE COOLED AND FIT BLANKING CAPS.
005

______________________________________________
DE-ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000
*****

AH

E N D

O F

T E X T

*****

30-31-00
OPT 10000-001
2-400 PAGE
5
MAR 01/12

30-31-00
6

AH

PROBES LOCATION

OPT 10000-001
MAR12

30-31-00
OPT 10000-001

2-400

PAGE
6
MAR 01/12

30-31-00
7

AH

COMPONENTS LOCATION

OPT 10000-001
MAR12

30-31-00
OPT 10000-001

2-400

PAGE
7
MAR 01/12

30-31-00

OPERATIONAL TEST OF
PITOT PROBES HEATING

OPT 10010-001
1

DEC14

ZONING DATA
___________
ZONE

: 113
210

114
211

212

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC

ELAPSED TIME

___
MEN

_________
MAN-HOURS
01

PUBLICATION
___________
JIC

: DC AND AC EXTERNAL POWER


SUPPLY

AH

24-40-00-EAD-10000

30-31-00
OPT 10010-001
2-400 PAGE
1
DEC 01/14

30-31-00

OPERATIONAL TEST OF
PITOT PROBES HEATING

001

OPT 10010-001
2

DEC14

___________________________________________
ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000

002

___________
PREPARATION
REF.FIG.303100-OPT-00100 (FIG.1)
REF.FIG.303100-OPT-00110 (FIG.2)
NOTE: IN ORDER TO SIMPLIFY THIS JIC THE THREE
SUBSYSTEMS (CAPT-F/O-STBY) HAVE BEEN
GROUPED. IN THIS WAY THE OPERATOR CAN MAKE REFERENCE TO ANY OF THE ABOVE MENTIONED GROUP INDEPENDENTLY
1. CAPT SUBSYSTEM:
ON PANEL 26VU (FIG.2-C) CHECK THAT
- TWO LEGENDS (PITOT AND STAT) OF PROBES
HTG/CAPT ANNUNCIATOR 63DA COME ON
- ALPHA LEGEND OF PROBES HTG/CAPT
ANNUNCIATOR 65DA COMES ON
- OFF LEGEND ON PROBES HTG/CAPT PUSHBUTTON
SWITCH 25DA (RELEASED) COMES ON
F/O SUBSYSTEM:
ON PANEL 26VU (FIG.2-C) CHECK THAT:
- TWO LEGENDS (PITOT AND STAT) OF PROBES
HTG/F/O ANNUNCIATOR 64DA COME ON
- ALPHA LEGEND OF PROBES HTG/F/O
ANNUNCIATOR 66DA COMES ON
- OFF LEGEND ON PROBES HTG/F/O PUSHBUTTON
SWITCH 22DA (RELEASED) COMES ON
STBY SUBSYSTEM:
ON PANEL 26VU (FIG.2-C) CHECK THAT
- TWO LEGENDS (PITOT AND STAT) OF PROBES
HTG/STBY ANNUNCIATOR 67DA COME ON
- OFF LEGEND ON PROBES HTG/STBY PUSHBUTTON
SWITCH 27DA (RELEASED) COMES ON
NOTE: TAT PROBE HEATING IS OPERATING ONLY IN
FLIGHT AND ALSO AN EVENTUAL FAILURE OF IT
*** CONTINUED ***
AH

30-31-00
OPT 10010-001
2-400 PAGE
2
DEC 01/14

30-31-00

OPERATIONAL TEST OF
PITOT PROBES HEATING

OPT 10010-001
3

DEC14

IS SHOWN ONLY IN FLIGHT, THEREFORE THE


INDICATING CONTROL IS OBTAINED AS FOLLOWS
ON PANEL 702VU (FIG.2-D)
PLACE NORM/FLT MODE SWITCH 57GB IN FLT
POSITION
CAPT SUBSYSTEM:
ON PANEL 26VU (FIG.2-C) CHECK THAT:
- TAT LEGEND OF ANNUNCIATOR 65DA
COMES ON TOO
- STAT LEGEND OF ANNUNCIATOR 63DA GOES OFF
F/O SUBSYSTEM:
ON PANEL 26VU (FIG.2-C) CHECK THAT:
- TAT LEGEND OF ANNUNCIATOR 66DA
COMES ON TOO
- STAT LEGEND OF ANNUNCIATOR 64DA GOES OFF
ON PANEL 702VU (FIG.2-D)
PLACE SWITCH 57GB IN NORM POSITION
2. REMOVE BLANKING CAPS FROM PROBES (FIG.1)
003

________________
OPERATIONAL
TEST
REF.FIG.303100-OPT-00100 (FIG.1)
REF.FIG.303100-OPT-00110 (FIG.2)
REF.FIG.242100-OPT-00100 (FIG.3)
01. ON PANEL 26VU(FIG.2-C)
PRESS PUSHBUTTON SWITCH PROBES HTG/STBY
- OFF LEGEND GOES OFF
- TWO LEGENDS (PITOT AND STAT) OF CAUT LTPROBES HTG/STBY/PITOT/STATIC GO OFF.
NOTE: THE MASTER CAUTION LIGHT ILLUMINATION
AND THE SINGLE CHIME WILL BE INHIBITED
WHEN BOTH HANDLES CLA ARE AT FTR AND
BELOW THIS POSITION.
02. ON PANEL 122VU(FIG.2-A)
OPEN THE FOLLOWING CIRCUIT BREAKER:
*** CONTINUED ***
AH

30-31-00
OPT 10010-001
2-400 PAGE
3
DEC 01/14

30-31-00

OPERATIONAL TEST OF
PITOT PROBES HEATING

OPT 10010-001
4

DEC14

5XB ACW ELEC PWR/ACW BUS CAUT RLY/BUS 1


03. VERIFY THAT THE CREW ALERTING SYSTEM IS
ACTIVATED IN THE FOLLOWING WAY:
A. SINGLE CHIME
B. ON PANELS 3VU AND 5VU (FIG.3-B)
CAPT AND F/O MASTER CAUTION LIGHTS 13WW
AND 168WW COME ON
C. ON PANEL 175WW (FIG.3-C)
ELEC CAUTION LIGHT COMES ON
04. ON PANELS 3VU AND 5VU
PUSH ON CAUTION LIGHT 13WW OR 168WW TO
RESET EITHER THESE ONES OR SINGLE CHIME
05. ON PANEL 26VU VERIFY THAT:
PITOT LEGEND OF CAUT LT-PROBES HTG/STBY/
PITOT/STATIC REMAINS OFF.
06. ON PANEL 122VU
OPEN THE FOLLOWING CIRCUIT BREAKER:
7DA PROBES HTG/STBY PITOT/EMER SPLY
07. VERIFY THAT THE CREW ALERTING SYSTEM IS
ACTIVATED IN THE FOLLOWING WAY:
A. SINGLE CHIME
B. ON PANELS 3VU AND 5VU
CAUTION LIGHTS 13WW AND 168WW COME ON
C. ON PANEL 175WW
ANTI-ICING CAUTION LIGHT COMES ON
08. ON PANELS 3VU AND 5VU
PUSH ON CAUTION LIGHT 13WW OR 168WW TO
RESET EITHER THESE ONES OR SINGLE CHIME
09. ON PANEL 26VU VERIFY THAT:
PITOT LEGEND OF CAUT LT-PROBES HTG/STBY/
PITOT/STATIC COMES ON.
10. ON PANEL 122VU
REMOVE SAFETY CLIPS AND TAGS AND CLOSE THE
*** CONTINUED ***
AH

30-31-00
OPT 10010-001
2-400 PAGE
4
DEC 01/14

30-31-00

OPERATIONAL TEST OF
PITOT PROBES HEATING

OPT 10010-001
5

DEC14

CIRCUIT BREAKERS PREVIOUSLY OPENED.


11. ON PANEL 175WW VERIFY THAT:
ELEC AND ANTI-ICING CAUTION LIGHTS GO OFF
12. ON PANEL 26VU VERIFY THAT:
PITOT LEGEND OF CAUT LT-PROBES HTG/STBY/
PITOT/STATIC GOES OFF.
13. ON PANEL 122VU
OPEN THE FOLLOWING CIRCUIT BREAKER:
57DA PROBES HTG/STBY PITOT/NORM SPLY
14. VERIFY THAT THE CREW ALERTING SYSTEM IS
ACTIVATED IN THE FOLLOWING WAY:
A. SINGLE CHIME
B. ON PANELS 3VU AND 5VU
CAUTION LIGHTS 13WW AND 168WW COME ON
C. ON PANEL 175WW
ANTI-ICING CAUTION LIGHT COMES ON
15. ON PANELS 3VU AND 5VU
PUSH ON CAUTION LIGHT 13WW OR 168WW TO
RESET EITHER THESE ONES OR SINGLE CHIME
16. ON PANEL 26VU VERIFY THAT:
PITOT LEGEND OF CAUT LT-PROBES HTG/STBY/
PITOT/STATIC COMES ON.
17. ON PANEL 122VU
REMOVE SAFETY CLIP AND TAG AND CLOSE THE
CIRCUIT BREAKER PREVIOUSLY OPENED.
18. ON PANEL 175WW VERIFY THAT:
ANTI-ICING CAUTION LIGHT GOES OFF
19. ON PANEL 26VU VERIFY THAT:
PITOT LEGEND OF CAUT LT-PROBES HTG/STBY/
PITOT/STATIC GOES OFF.

*** CONTINUED ***


AH

30-31-00
OPT 10010-001
2-400 PAGE
5
DEC 01/14

30-31-00

OPERATIONAL TEST OF
PITOT PROBES HEATING

004

OPT 10010-001
6

DEC14

________
CLOSE-UP
REF.FIG.303100-OPT-00100(FIG.1) AND 303100-OPT00110(FIG.2)
1. CAPT SUBSYSTEM:
- ON PANEL 26VU(FIG.2-C)
RELEASE PUSHBUTTON SWITCH
F/O SUBSYSTEM:
- ON PANEL 26VU(FIG.2-C)
RELEASE PUSHBUTTON SWITCH
STBY SUBSYSTEM:
- ON PANEL 26VU(FIG.2-C)
RELEASE PUSHBUTTON SWITCH
- ON PANEL 702VU(FIG.2-D)
PLACE SWITCH 57GB IN NORM

25DA
22DA
27DA
POSITION

2. WAIT UNTIL PROBES HAVE COOLED AND FIT BLANKING CAPS.


005

______________________________________________
DE-ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000
*****

AH

E N D

O F

T E X T

*****

30-31-00
OPT 10010-001
2-400 PAGE
6
DEC 01/14

30-31-00
7

AH

PROBES LOCATION

OPT 10010-001
DEC14

30-31-00
OPT 10010-001

2-400

PAGE
7
DEC 01/14

30-31-00
8

AH

COMPONENTS LOCATION

OPT 10010-001
DEC14

30-31-00
OPT 10010-001

2-400

PAGE
8
DEC 01/14

30-31-00
9

AH

CONTROLS AND INDICATING

OPT 10010-001
DEC14

30-31-00
OPT 10010-001

2-400

PAGE
9
DEC 01/14

30-31-00

OPERATIONAL TEST OF
PITOT PROBES HEATING

OPT 10010-002
1

DEC14

ZONING DATA
___________
ZONE

: 113
210

114
211

212

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC

ELAPSED TIME

___
MEN

_________
MAN-HOURS
01

PUBLICATION
___________
JIC
JIC

: PRINCIPLE OF CDS USE


(DISPLAY UNITS
EXPLORATION)
: DC AND AC EXTERNAL POWER
SUPPLY

AH

31-63-00-PRO-10000
24-40-00-EAD-10000

30-31-00
OPT 10010-002
2-400 PAGE
1
DEC 01/14

30-31-00

OPERATIONAL TEST OF
PITOT PROBES HEATING

001

OPT 10010-002
2

DEC14

PRINCIPLE OF CDS USE (DISPLAY UNITS


___________________________________
EXPLORATION)
____________
(TO USE ONLY IF NEEDED)
_______________________
SEE JOB INSTRUCTION CARD
316300-PRO-10000
NOTE: PROCEDURE TO USE ONLY IF NEEDED.
THIS PROCEDURE DESCRIBES LOCATION AND
MANAGEMENT OF THE DIFFERENT DISPLAY
WINDOWS PROVIDED BY THE THREE FORMATS
(PFD, EWD, MFD) PROPOSED ON THE FIVE
DISPLAY UNITS (DU).

002

___________________________________________
ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000

003

___________
PREPARATION
REF.FIG.303100-OPT-00100 (FIG.1)
REF.FIG.303100-OPT-00110 (FIG.2)
NOTE: IN ORDER TO SIMPLIFY THIS JIC THE THREE
SUBSYSTEMS (CAPT-F/O-STBY) HAVE BEEN
GROUPED. IN THIS WAY THE OPERATOR CAN MAKE REFERENCE TO ANY OF THE ABOVE MENTIONED GROUP INDEPENDENTLY
1. CAPT SUBSYSTEM:
ON PANEL 26VU (FIG.2-C) CHECK THAT
- TWO LEGENDS (PITOT AND STAT) OF PROBES
HTG/CAPT ANNUNCIATOR 63DA COME ON
- ALPHA LEGEND OF PROBES HTG/CAPT
ANNUNCIATOR 65DA COMES ON
- OFF LEGEND ON PROBES HTG/CAPT PUSHBUTTON
SWITCH 25DA (RELEASED) COMES ON
F/O SUBSYSTEM:
ON PANEL 26VU (FIG.2-C) CHECK THAT:
- TWO LEGENDS (PITOT AND STAT) OF PROBES
*** CONTINUED ***
AH

30-31-00
OPT 10010-002
2-400 PAGE
2
DEC 01/14

30-31-00

OPERATIONAL TEST OF
PITOT PROBES HEATING

OPT 10010-002
3

DEC14

HTG/F/O ANNUNCIATOR 64DA COME ON


- ALPHA LEGEND OF PROBES HTG/F/O
ANNUNCIATOR 66DA COMES ON
- OFF LEGEND ON PROBES HTG/F/O PUSHBUTTON
SWITCH 22DA (RELEASED) COMES ON
STBY SUBSYSTEM:
ON PANEL 26VU (FIG.2-C) CHECK THAT
- TWO LEGENDS (PITOT AND STAT) OF PROBES
HTG/STBY ANNUNCIATOR 67DA COME ON
- OFF LEGEND ON PROBES HTG/STBY PUSHBUTTON
SWITCH 27DA (RELEASED) COMES ON
NOTE: TAT PROBE HEATING IS OPERATING ONLY IN
FLIGHT AND ALSO AN EVENTUAL FAILURE OF IT
IS SHOWN ONLY IN FLIGHT, THEREFORE THE
INDICATING CONTROL IS OBTAINED AS FOLLOWS
ON PANEL 702VU (FIG.2-D)
PLACE NORM/FLT MODE SWITCH 57GB IN FLT
POSITION
CAPT SUBSYSTEM:
ON PANEL 26VU (FIG.2-C) CHECK THAT:
- TAT LEGEND OF ANNUNCIATOR 65DA
COMES ON TOO
- STAT LEGEND OF ANNUNCIATOR 63DA GOES OFF
F/O SUBSYSTEM:
ON PANEL 26VU (FIG.2-C) CHECK THAT:
- TAT LEGEND OF ANNUNCIATOR 66DA
COMES ON TOO
- STAT LEGEND OF ANNUNCIATOR 64DA GOES OFF
ON PANEL 702VU (FIG.2-D)
PLACE SWITCH 57GB IN NORM POSITION
2. REMOVE BLANKING CAPS FROM PROBES (FIG.1)
004

________________
OPERATIONAL
TEST
REF.FIG.303100-OPT-00100 (FIG.1)
REF.FIG.303100-OPT-00110 (FIG.2)
REF.FIG.242100-OPT-00100 (FIG.3)
*** CONTINUED ***
AH

30-31-00
OPT 10010-002
2-400 PAGE
3
DEC 01/14

30-31-00

OPERATIONAL TEST OF
PITOT PROBES HEATING

OPT 10010-002
4

DEC14

01. ON PANEL 26VU(FIG.2-C)


PRESS PUSHBUTTON SWITCH PROBES HTG/STBY
- OFF LEGEND GOES OFF
- TWO LEGENDS (PITOT AND STAT) OF CAUT LTPROBES HTG/STBY/PITOT/STATIC GO OFF.
NOTE: THE MASTER CAUTION LIGHT ILLUMINATION
AND THE SINGLE CHIME WILL BE INHIBITED
WHEN BOTH HANDLES CLA ARE AT FTR AND
BELOW THIS POSITION.
02. ON PANEL 122VU(FIG.2-A)
OPEN THE FOLLOWING CIRCUIT BREAKER:
5XB ACW ELEC PWR/ACW BUS CAUT RLY/BUS 1
03. VERIFY THAT THE CREW ALERTING SYSTEM IS
ACTIVATED IN THE FOLLOWING WAY:
A. SINGLE CHIME
B. (FIG.3-B) CAPT AND F/O MASTER CAUTION
LIGHTS COME ON.
C. ON EWD, IN ALERT WINDOW, ELEC ACW 1
MESSAGE IS DISPLAYED.
04. PUSH ON MASTER CAUTION LIGHT TO RESET
EITHER THESE ONES OR SINGLE CHIME.
05. ON PANEL 26VU VERIFY THAT:
PITOT LEGEND OF CAUT LT-PROBES HTG/STBY/
PITOT/STATIC REMAINS OFF.
06. ON PANEL 122VU
OPEN THE FOLLOWING CIRCUIT BREAKER:
7DA PROBES HTG/STBY PITOT/EMER SPLY
07. VERIFY THAT THE CREW ALERTING SYSTEM IS
ACTIVATED IN THE FOLLOWING WAY:
A. SINGLE CHIME
B. CAUTION LIGHTS COME ON
C. ON EWD, IN ALERT WINDOW, A-ICING PIT
SBY MESSAGE IS DISPLAYED.
*** CONTINUED ***
AH

30-31-00
OPT 10010-002
2-400 PAGE
4
DEC 01/14

30-31-00

OPERATIONAL TEST OF
PITOT PROBES HEATING

OPT 10010-002
5

DEC14

08. PUSH ON MASTER CAUTION LIGHT TO


RESET EITHER THESE ONES OR SINGLE CHIME.
09. ON PANEL 26VU VERIFY THAT:
PITOT LEGEND OF CAUT LT-PROBES HTG/STBY/
PITOT/STATIC COMES ON.
10. ON PANEL 122VU
REMOVE SAFETY CLIPS AND TAGS AND CLOSE THE
CIRCUIT BREAKERS PREVIOUSLY OPENED.
11. ON EWD, IN ALERT WINDOW, ELEC ACW 1 AND
A-ICING PIT SBY MESSAGES DISAPPEAR.
12. ON PANEL 26VU VERIFY THAT:
PITOT LEGEND OF CAUT LT-PROBES HTG/STBY/
PITOT/STATIC GOES OFF.
13. ON PANEL 122VU
OPEN THE FOLLOWING CIRCUIT BREAKER:
57DA PROBES HTG/STBY PITOT/NORM SPLY
14. VERIFY THAT THE CREW ALERTING SYSTEM IS
ACTIVATED IN THE FOLLOWING WAY:
A. SINGLE CHIME
B. CAUTION LIGHTS COME ON
C. ON EWD, IN ALERT WINDOW, A-ICING PIT
SBY MESSAGE IS DISPLAYED.
15. PUSH ON MASTER CAUTION LIGHT TO
RESET EITHER THESE ONES OR SINGLE CHIME.
16. ON PANEL 26VU VERIFY THAT:
PITOT LEGEND OF CAUT LT-PROBES HTG/STBY/
PITOT/STATIC COMES ON.
17. ON PANEL 122VU
REMOVE SAFETY CLIP AND TAG AND CLOSE THE
CIRCUIT BREAKER PREVIOUSLY OPENED.
18. ON EWD, IN ALERT WINDOW, A-ICING PIT SBY
*** CONTINUED ***
AH

30-31-00
OPT 10010-002
2-400 PAGE
5
DEC 01/14

30-31-00

OPERATIONAL TEST OF
PITOT PROBES HEATING

OPT 10010-002
6

DEC14

MESSAGE DISAPPEARS.
19. ON PANEL 26VU VERIFY THAT:
PITOT LEGEND OF CAUT LT-PROBES HTG/STBY/
PITOT/STATIC GOES OFF.
005

________
CLOSE-UP
REF.FIG.303100-OPT-00100(FIG.1) AND 303100-OPT00110(FIG.2)
1. CAPT SUBSYSTEM:
- ON PANEL 26VU(FIG.2-C)
RELEASE PUSHBUTTON SWITCH
F/O SUBSYSTEM:
- ON PANEL 26VU(FIG.2-C)
RELEASE PUSHBUTTON SWITCH
STBY SUBSYSTEM:
- ON PANEL 26VU(FIG.2-C)
RELEASE PUSHBUTTON SWITCH
- ON PANEL 702VU(FIG.2-D)
PLACE SWITCH 57GB IN NORM

25DA
22DA
27DA
POSITION

2. WAIT UNTIL PROBES HAVE COOLED AND FIT BLANKING CAPS.


006

______________________________________________
DE-ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000
*****

AH

E N D

O F

T E X T

*****

30-31-00
OPT 10010-002
2-400 PAGE
6
DEC 01/14

30-31-00
7

AH

PROBES LOCATION

OPT 10010-002
DEC14

30-31-00
OPT 10010-002

2-400

PAGE
7
DEC 01/14

30-31-00
8

AH

COMPONENTS LOCATION

OPT 10010-002
DEC14

30-31-00
OPT 10010-002

2-400

PAGE
8
DEC 01/14

30-31-00
9

AH

CONTROLS AND INDICATING

OPT 10010-002
DEC14

30-31-00
OPT 10010-002

2-400

PAGE
9
DEC 01/14

30-31-83

REMOVAL AND INSTALLATION


OF CURRENT SENSORS

RAI 10000-001
1

MAR15

ZONING DATA
___________
ZONE
ACCESS

: 212
214
220
: 212TZ 212VZ 214BZ 214PZ 222CZ 222FZ 222QZ 222RZ

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC

___
MEN

_________
MAN-HOURS
01

ELAPSED TIME

SPARE

: 06 CURRENT SENSOR: 28V


07 CURRENT SENSOR:115V

30-31-80-XX-XXX
30-31-80-XX-XXX

: PROBE ICE PROTECTION CAP


F/O STBY SUBSYSTEM

30-31-00-OPT-10000

PUBLICATION
___________
JIC

AH

30-31-83
RAI 10000-001
2-400 PAGE
1
MAR 01/15

30-31-83

REMOVAL AND INSTALLATION


OF CURRENT SENSORS

001

RAI 10000-001
2

MAR15

___________
PREPARATION
REF. FIG. 240000-RAI-00100 (FIG.1)
REF. FIG. 240000-RAI-00103 (FIG.2)
1. MAKE CERTAIN THAT THE GROUND POWER UNIT IS
NOT CONNECTED TO THE DC AND AC EXTERNAL POWER RECEPTACLES (ON PANELS 5002VU AND 5000VU
-FIG.1-F AND D) AND THE ACCESS DOORS 114BR
AND 114CR (FIG.1-E AND C) ARE CLOSED
2. ON PANEL 29VU (FIG.1-A) MAKE CERTAIN THAT:
BAT SELECTOR SWITCH 7PA IS IN OFF POSITION
3. DISPLAY A WARNING NOTICE ON PANELS 29VU AND
26VU (FIG.1-B) PROHIBITING POWER SUPPLY TO
SYSTEM
4. ON DC/AC POWER CENTER 120VU OR ON ELECTRONICS RACK 90VU (FIG.2 A AND B AND THE CORRESPONDING FIGURE OF EACH RAI)
120VU: REMOVE ACCESS PANEL 212TZ OR 212VZ
(123VU) OR CIRCUIT BREAKER PANEL 121V
U OR 122VU OR 124VU OR 125VU OR 126VU
OR 127VU OR 128VU OR 129VU OR 130VU
90VU - SIDE SHELF: REMOVE ACCESS PANEL 222RZ
(SHELF 91VU) OR 222QZ (SHELF 91VU OR
92VU OR 93VU) OR 222PZ (SHELF 94VU OR
95VU)
- FRONT SHELF: REMOVE ACCESS PANEL 214
CZ(SHELF 91VU OR 92VU) OR 214BZ(SHELF
93VU OR 94VU OR 95VU)

002

_______
REMOVAL
THIS REMOVAL/INSTALLATION PROCEDURE IS APPLICABLE TO THE FOLLOWING COMPONENTS:
---COMPONENT-----------------ZONE--ACCESS--FIN115V
CURRENT SNSR-AC,F/O ALPHA PROBE
- 222
93VU 40DA
*** CONTINUED ***
AH

30-31-83
RAI 10000-001
2-400 PAGE
2
MAR 01/15

30-31-83

REMOVAL AND INSTALLATION


OF CURRENT SENSORS

CURRENT SNSR-AC,CAPT ALPHA PROBE


CURRENT SNSR-AC,F/O PITOT PROBE
CURRENT SNSR-AC,CAPT PITOT PROBE
CURRENT SNSR-AC,CAPT TAT
PROBE
CURRENT SNSR-AC,STBY PITOT
PROBE
CURRENT SNSR-AC,F/O TAT
PROBE
28V
---------------------CURRENT SNSR-DC,STBY L
STATIC PROBE CURRENT SNSR-DC,CAPT L
STATIC PROBE CURRENT SNSR-DC,F/O L
STATIC PROBE CURRENT SNSR-DC,STBY R
STATIC PROBE CURRENT SNSR-DC,CAPT R
STATIC PROBE CURRENT SNSR-DC,F/O R
STATIC PROBE -

RAI 10000-001
3

222

92VU

41DA

222

93VU

42DA

222

92VU

43DA

222

94VU

45DA

222

94VU

47DA

222

93VU

68DA

222

94VU

29DA

222

92VU

31DA

222

93VU

33DA

222

94VU

34DA

222

92VU

36DA

222

93VU

38DA

MAR15

REF.FIG.303110-RAI-00100
1. REMOVE SCREWS(3) SECURING CURRENT SENSOR(1)
2. REMOVE CURRENT SENSOR FROM ITS BASE(2) TAKING CARE NOT TO DAMAGE ELECTRICAL CONNECTOR
003

____________
INSTALLATION
REF.FIG.303110-RAI-00100
1. CLEAN AND INSPECT COMPONENT INTERFACE AND/
OR COMPONENT ADJACENT AREA.
2. CHECK FOR CORRECT CONDITION OF ELECTRICAL
*** CONTINUED ***
AH

30-31-83
RAI 10000-001
2-400 PAGE
3
MAR 01/15

30-31-83

REMOVAL AND INSTALLATION


OF CURRENT SENSORS

RAI 10000-001
4

MAR15

CONNECTORS
3. INSTALL CURRENT SENSOR(1) ON ITS BASE(2)
4. INSTALL SCREWS(3). TIGHTEN SCREWS
004

________
CLOSE
UP
REF. FIG. 240000-RAI-00100 (FIG.1)
REF. FIG. 240000-RAI-00103 (FIG.2)
1. ON DC/AC POWER CENTER 12OVU OR ON ELECTRONICS RACK 90VU (FIG.2 A OR B AND THE CORRESPONDING FIGURE OF EACH RAI)
120VU: CLOSE ACCESS PANEL 212TZ OR 212VZ OR
CIRCUIT BREAKER PANEL 121VU OR 122VU
OR 124VU OR 125VU OR 127VU OR 128VU
OR 129VU OR 130VU
90VU - SIDE SHELF: CLOSE ACCESS PANEL 222RZ
OR 222QZ OR 222PZ
- FRONT SHELF: CLOSE ACCESS PANEL 214CZ
OR 214BZ
2. REMOVE THE WARNING NOTICE FROM PANELS 29VU
AND 26VU (FIG.1-A AND B)

005

________________
OPERATIONAL
TEST
SEE JOB INSTRUCTION CARD
303100-OPT-10000
*****

AH

E N D

O F

T E X T

*****

30-31-83
RAI 10000-001
2-400 PAGE
4
MAR 01/15

30-31-83
5

AH

REM/INS OF CURRENT
SENSOR

RAI 10000-001
MAR15

30-31-83
RAI 10000-001

2-400

PAGE
5
MAR 01/15

30-31-83
6

AH

CONTROLS AND INDICATING

RAI 10000-001
MAR15

30-31-83
RAI 10000-001

2-400

PAGE
6
MAR 01/15

30-31-83
7

AH

ACCESS DOORS, C/B PANELS


& SHELVES (90VU - 120VU)

RAI 10000-001
MAR15

30-31-83
RAI 10000-001

2-400

PAGE
7
MAR 01/15

30-42-00

OPERATIONAL TEST OF
WINDSHIELD HEATING

OPT 10000-001
1

MAR14

ZONING DATA
___________
ZONE

: 210

211

212

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC

ELAPSED TIME

___
MEN

_________
MAN-HOURS
01

PUBLICATION
___________
JIC

: DC AND AC EXTERNAL POWER


SUPPLY

AH

24-40-00-EAD-10000

30-42-00
OPT 10000-001
2-400 PAGE
1
MAR 01/14

30-42-00

OPERATIONAL TEST OF
WINDSHIELD HEATING

001

OPT 10000-001
2

MAR14

___________________________________________
ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000

002

___________
PREPARATION
REF. FIG. 304200-OPT-00100
ON PANEL 26VU(B) CHECK THAT:
-OFF LEGEND ON WINDSHIELD HTG/L(R)
-PUSHBUTTON SWITCH (RELEASED) COMES ON.

003

________________
OPERATIONAL
TEST
REF.FIG. 304200-OPT-00100
1. ON PANEL 26VU(B)
PRESS PUSHBUTTON SWITCH 9DG(10DG)
- OFF LEGEND GOES OFF
2. WAIT AT LEAST 5 MINUTES AND THEN ON WINDSHIELDS VERIFY WITH HAND THAT THE HEATING
SYSTEM IS OPERATING

004

________
CLOSE
UP
REF. FIG. 304200-OPT-00100
1. ON PANEL 26VU(B)
RELEASE PUSHBUTTON SWITCH WINDSHIELD
HTG/L(R).

005

______________________________________________
DE-ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000
*****

AH

E N D

O F

T E X T

*****

30-42-00
OPT 10000-001
2-400 PAGE
2
MAR 01/14

30-42-00
3

AH

CONTROLS AND INDICATING

OPT 10000-001
MAR14

30-42-00
OPT 10000-001

2-400

PAGE
3
MAR 01/14

30-42-00

OPERATIONAL TEST OF SIDE


WINDOW HEATING

OPT 10010-001
1

DEC14

ZONING DATA
___________
ZONE

: 210

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC

ELAPSED TIME

___
MEN

_________
MAN-HOURS
01

PUBLICATION
___________
JIC

: DC AND AC EXTERNAL POWER


SUPPLY

AH

24-40-00-EAD-10000

30-42-00
OPT 10010-001
2-400 PAGE
1
DEC 01/14

30-42-00

OPERATIONAL TEST OF SIDE


WINDOW HEATING

001

OPT 10010-001
2

DEC14

___________________________________________
ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000

002

___________
PREPARATION
REF.FIG.304200 OPT 00110
REF.FIG.304200 OPT 00120
1. MAKE CERTAIN THAT THE FOLLOWING CIRCUIT
BREAKERS ARE CLOSED:
- ON PANEL 122VU(A)
1DG(2DG) WDO/HTG/AI/WSHLD R IND L/SIDE
WDO/L(R) CTL
29DG
WDO HTG/AI/SIDE WDO/CAUTION
- ON PANEL 127VU(124VU) (A)
3DG(4DG) PWR SPLY ON PRIM DC BUS1(2)/L(R)
SIDE WINDOW ANTI-ICING
2. ON PANEL 24VU (C) CHECK THAT:
FAULT AND ON LEGENDS ON SIDE WINDOWS PUSHBUTTON SWITCH 22DG (RELEASED) ARE OFF
3. DISCONNECT ELECTRICAL CONNECTORS 13 DGA
(14 DGA),AND COVER IT WITH BLANKING CAP.

003

________________
OPERATIONAL
TEST
REF.FIG. 304200 OPT 00110
REF.FIG. 304200 OPT 00120
1. ON PANEL 24VU PRESS SIDE WINDOWS PUSH
BUTTON SWITCH 22DG:
- ON LEGEND COMES ON
2. VERIFY THAT:
- ON PANEL 24VU FAULT LIGHT COMES ON
- ON PANEL 175WW ANTI-ICING CAUTION LIGHT
COMES ON
- ON PANELS 3VU AND 5VU CAUTION AMBER LIGHT
COMES ON WITH A SINGLE CHIME THROUGH THE
COCKPIT LOADSPEAKER.
*** CONTINUED ***
AH

30-42-00
OPT 10010-001
2-400 PAGE
2
DEC 01/14

30-42-00

OPERATIONAL TEST OF SIDE


WINDOW HEATING

004

OPT 10010-001
3

DEC14

________
CLOSE
UP
REF.FIG.304200-OPT-00110
REF.FIG.304200-OPT-00120
1. ON PANEL 24VU(C)
RELEASE PUSHBUTTON SWITCH 22DG
2. REMOVE BLANKING CAPS FROM CONNECTORS.
3. CONNECT ELECTRIOCAL CONNECTORS 13 DGA
(14 DGA)

005

______________________________________________
DE-ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000
*****

AH

E N D

O F

T E X T

*****

30-42-00
OPT 10010-001
2-400 PAGE
3
DEC 01/14

30-42-00
4

AH

CONTROLS AND INDICATING

OPT 10010-001
DEC14

30-42-00
OPT 10010-001

2-400

PAGE
4
DEC 01/14

30-42-00
5

AH

OPERATIONAL TEST

OPT 10010-001
DEC14

30-42-00
OPT 10010-001

2-400

PAGE
5
DEC 01/14

30-42-00

OPERATIONAL TEST OF SIDE


WINDOW HEATING

OPT 10010-002
1

DEC14

ZONING DATA
___________
ZONE

: 210

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC

ELAPSED TIME

___
MEN

_________
MAN-HOURS
01

PUBLICATION
___________
JIC

: DC AND AC EXTERNAL POWER


SUPPLY

AH

24-40-00-EAD-10000

30-42-00
OPT 10010-002
2-400 PAGE
1
DEC 01/14

OPERATIONAL TEST OF SIDE


WINDOW HEATING

001

30-42-00

OPT 10010-002
2

DEC14

___________________________________________
ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000

002

___________
PREPARATION
REF.FIG.304200 OPT 00110
REF.FIG.304200 OPT 00120
1. MAKE CERTAIN THAT THE FOLLOWING CIRCUIT
BREAKERS ARE CLOSED:
- ON PANEL 122VU(A)
1DG(2DG) WDO/HTG/AI/WSHLD R IND L/SIDE
WDO/L(R) CTL
29DG
WDO HTG/AI/SIDE WDO/CAUTION
- ON PANEL 127VU(124VU) (A)
3DG(4DG) PWR SPLY ON PRIM DC BUS1(2)/L(R)
SIDE WINDOW ANTI-ICING
2. ON PANEL 24VU (C) CHECK THAT:
FAULT AND ON LEGENDS ON SIDE WINDOWS PUSHBUTTON SWITCH 22DG (RELEASED) ARE OFF
3. DISCONNECT ELECTRICAL CONNECTORS 13 DGA
(14 DGA),AND COVER IT WITH BLANKING CAP.

003

________________
OPERATIONAL
TEST
REF.FIG. 304200 OPT 00110
REF.FIG. 304200 OPT 00120
1. ON PANEL 24VU PRESS SIDE WINDOWS
PUSHBUTTON SWITCH 22DG:
- ON LEGEND COMES ON.
- FAULT LIGHT COMES ON (ON PANEL 24VU).
- CAUTION(MASTER CAUT) ANNUNCIATORS
COME ON.
- SINGLE CHIME SOUNDS.
- A-ICING WINDOWS MESSAGE IS DISPLAYED
(ON EWD ALERT WINDOW).

*** CONTINUED ***


AH

30-42-00
OPT 10010-002
2-400 PAGE
2
DEC 01/14

30-42-00

OPERATIONAL TEST OF SIDE


WINDOW HEATING

004

OPT 10010-002
3

DEC14

________
CLOSE
UP
REF.FIG.304200-OPT-00110
REF.FIG.304200-OPT-00120
1. ON PANEL 24VU(C)
RELEASE PUSHBUTTON SWITCH 22DG
2. REMOVE BLANKING CAPS FROM CONNECTORS.
3. CONNECT ELECTRIOCAL CONNECTORS 13 DGA
(14 DGA)

005

______________________________________________
DE-ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000
*****

AH

E N D

O F

T E X T

*****

30-42-00
OPT 10010-002
2-400 PAGE
3
DEC 01/14

30-42-00
4

AH

CONTROLS AND INDICATING

OPT 10010-002
DEC14

30-42-00
OPT 10010-002

2-400

PAGE
4
DEC 01/14

30-42-00
5

AH

OPERATIONAL TEST

OPT 10010-002
DEC14

30-42-00
OPT 10010-002

2-400

PAGE
5
DEC 01/14

30-42-00

OPT OF WINDSHIELD TEMPERATURE CONTROLLERS AND


ASSOCIATED CIRCUITS

OPT 10020-001
1

DEC14

ZONING DATA
___________
ZONE

: 210

211

212

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC

ELAPSED TIME

___
MEN

_________
MAN-HOURS
01

PUBLICATION
___________
JIC

: DC AND AC EXTERNAL POWER


SUPPLY

AH

24-40-00-EAD-10000

30-42-00
OPT 10020-001
2-400 PAGE
1
DEC 01/14

30-42-00

OPT OF WINDSHIELD TEMPERATURE CONTROLLERS AND


ASSOCIATED CIRCUITS

001

OPT 10020-001
2

DEC14

___________________________________________
ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000

002

___________
PREPARATION
REF. FIG. 304200-OPT-00100
ON PANEL 26VU(B) CHECK THAT:
-OFF LEGEND ON WINDSHIELD HTG/L(R)
-PUSHBUTTON SWITCH (RELEASED) COMES ON.

003

________________
OPERATIONAL
TEST
REF. FIG. 304211-OPT-00100
1. ON PANEL 26VU (WINDSHIELD HTG SECTION) (B)
PRESS WINDSHIELD HTG L(R) PUSHBUTTON
SWITCHES
- OFF LEGENDS GO OFF
NOTE: IF AN INOPERATIVE FAILURE IS SHOWN BY
ENERGIZATION OF BITE LOADED MAGNETIC
INDICATOR, IT IS NOT POSSIBLE TO
PERFORM THE TEST (SEE TSM).
2. ON PANEL 702VU (WINDSHIELD HTG SECTION) (C)
PRESS AND HOLD WINDSHIELD HTG/PTT SWITCH
FOR AT LEAST 5 SECONDS AND VERIFY THAT
- ON PANEL 26VU, FAULT LEGENDS ON PUSHBUTTON
SWITCHES WINDSHIELD HTG/L(R) COME ON
- ON PANEL 175WW (B), ANTI-ICING CAUTION
LIGHT COMES ON
- MASTER CAUTION LIGHTS COME ON ASSOCIATED
WITH A SINGLE CHIME
NOTE: DO NOT RELEASE WINDSHIELD HTG/PTT
BEFORE FINISHING TEST.
NOTE: THE MASTER CAUTION LIGHT ILLUMINATION
*** CONTINUED ***
AH

30-42-00
OPT 10020-001
2-400 PAGE
2
DEC 01/14

30-42-00

OPT OF WINDSHIELD TEMPERATURE CONTROLLERS AND


ASSOCIATED CIRCUITS

OPT 10020-001
3

DEC14

AND THE SINGLE CHIME WILL BE


INHIBITED WHEN BOTH HANDLES CLA
ARE AT FTR AND BELOW THIS POSITION.
004

________
CLOSE
UP
REF. FIG. 304200-OPT-00100
1. ON PANEL 26VU(B)
RELEASE PUSHBUTTON SWITCH WINDSHIELD
HTG/L(R).

005

______________________________________________
DE-ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000
*****

AH

E N D

O F

T E X T

*****

30-42-00
OPT 10020-001
2-400 PAGE
3
DEC 01/14

30-42-00
4

AH

CONTROLS AND INDICATING

OPT 10020-001
DEC14

30-42-00
OPT 10020-001

2-400

PAGE
4
DEC 01/14

30-42-00
5

AH

CONTROLS AND INDICATING

OPT 10020-001
DEC14

30-42-00
OPT 10020-001

2-400

PAGE
5
DEC 01/14

30-42-00

OPT OF WINDSHIELD TEMPERATURE CONTROLLERS AND


ASSOCIATED CIRCUITS

OPT 10020-003
1

DEC14

ZONING DATA
___________
ZONE

: 210

211

212

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC

ELAPSED TIME

___
MEN

_________
MAN-HOURS
01

PUBLICATION
___________
JIC
JIC

: PRINCIPLE OF CDS USE


(DISPLAY UNITS
EXPLORATION)
: DC AND AC EXTERNAL POWER
SUPPLY

AH

31-63-00-PRO-10000
24-40-00-EAD-10000

30-42-00
OPT 10020-003
2-400 PAGE
1
DEC 01/14

30-42-00

OPT OF WINDSHIELD TEMPERATURE CONTROLLERS AND


ASSOCIATED CIRCUITS

001

OPT 10020-003
2

DEC14

PRINCIPLE OF CDS USE (DISPLAY UNITS


___________________________________
EXPLORATION)
____________
(TO USE ONLY IF NEEDED)
_______________________
SEE JOB INSTRUCTION CARD
316300-PRO-10000
NOTE: PROCEDURE TO USE ONLY IF NEEDED.
THIS PROCEDURE DESCRIBES LOCATION AND
MANAGEMENT OF THE DIFFERENT DISPLAY
WINDOWS PROVIDED BY THE THREE FORMATS
(PFD, EWD, MFD) PROPOSED ON THE FIVE
DISPLAY UNITS (DU).

002

___________________________________________
ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000

003

___________
PREPARATION
REF. FIG. 304200-OPT-00100
ON PANEL 26VU(B) CHECK THAT:
-OFF LEGEND ON WINDSHIELD HTG/L(R)
-PUSHBUTTON SWITCH (RELEASED) COMES ON.

004

________________
OPERATIONAL
TEST
REF. FIG. 304211-OPT-00100
1. ON PANEL 26VU (WINDSHIELD HTG SECTION) (B)
PRESS WINDSHIELD HTG L(R) PUSHBUTTON
SWITCHES.
- OFF LEGENDS GO OFF
NOTE: IF AN INOPERATIVE FAILURE IS SHOWN BY
ENERGIZATION OF BITE LOADED MAGNETIC
INDICATOR, IT IS NOT POSSIBLE TO
PERFORM THE TEST (SEE TSM).
*** CONTINUED ***
AH

30-42-00
OPT 10020-003
2-400 PAGE
2
DEC 01/14

30-42-00

OPT OF WINDSHIELD TEMPERATURE CONTROLLERS AND


ASSOCIATED CIRCUITS

OPT 10020-003
3

DEC14

2. ON PANEL 702VU (WINDSHIELD HTG SECTION) (C)


PRESS AND HOLD WINDSHIELD HTG/PTT SWITCH
DURING THE TEST.
AFTER 5 SECONDS VERIFY THAT:
- ON PANEL 26VU, FAULT LEGENDS ON
WINDSHIELD HTG L(R) PUSHBUTTON SWITCHES
COME ON.
- ON EWD, IN ALERT WINDOW, A-ICING
L WINDSHIELD AND A-ICING R WINDSHIELD
MESSAGES ARE DISPLAYED.
- MASTER CAUTION LIGHTS COME ON ASSOCIATED
WITH A SINGLE CHIME.
NOTE: DO NOT RELEASE WINDSHIELD HTG/PTT
BEFORE FINISHING TEST.
NOTE: THE MASTER CAUTION LIGHT ILLUMINATION
AND THE SINGLE CHIME WILL BE INHIBITED
WHEN BOTH HANDLES CLA ARE AT FTR AND
BELOW THIS POSITION.
005

________
CLOSE
UP
REF. FIG. 304200-OPT-00100
1. ON PANEL 26VU(B)
RELEASE PUSHBUTTON SWITCH WINDSHIELD
HTG/L(R).

006

______________________________________________
DE-ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000
*****

AH

E N D

O F

T E X T

*****

30-42-00
OPT 10020-003
2-400 PAGE
3
DEC 01/14

30-42-00
4

AH

CONTROLS AND INDICATING

OPT 10020-003
DEC14

30-42-00
OPT 10020-003

2-400

PAGE
4
DEC 01/14

30-42-00
5

AH

CONTROLS AND INDICATING

OPT 10020-003
DEC14

30-42-00
OPT 10020-003

2-400

PAGE
5
DEC 01/14

30-42-00

SWAPPING PROCEDURE OF
THERMAL SENSOR FOR
WINDSHIELD

PRO 10000-001
1

APR05

ZONING DATA
___________
ZONE
ACCESS

: 210
: 211JW

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

___
MEN

_________
MAN-HOURS

PUBLICATION
___________
JIC

: MAIN WINDSHIELD CONTROLLERS AND ASSOCIATED CIRCUITS

AH

30-42-00-OPT-10020

30-42-00
PRO 10000-001
2-400 PAGE
1
APR 01/05

30-42-00

SWAPPING PROCEDURE OF
THERMAL SENSOR FOR
WINDSHIELD

001

PRO 10000-001
2

APR05

___________
PREPARATION
REF. FIG. 304200-PRO-00100
1. OPEN SAFETY CLIP AND TAG THE FOLLOWING
CIRCUIT BREAKERS:
- ON PANEL 122VU
1DG(2DG) WINDOWS/L(R) WSHLD HTG IND &
L(R) SIDE WINDOW ANTI ICING CTL
& IND
- ON PANEL 126VU
5DG(6DG) L(R) WINDSHIELD HTG PWR SPLY
2. UNSCREW CAM-LOCK (1) AND REMOVE ACCESS
PANEL 211JW (2).

002

_________
PROCEDURE
REF. FIG 304200-PRO-00100
1. UNPLUG ELECTRICAL CONNECTOR 15DGA(16DGA)
2. FROM CONNECTOR 15DGA(16DGA) DISCONNECT WIRE
CONNECTED TO PINS C AND D (NORMAL SENSOR)
OR G AND A (OVHT SENSOR) RESPECTIVELY CON
NET THEM TO PINS E AND F.
3. PLUG ELECTRICAL CONNECTOR 15DGA(16DGA).

003

________
CLOSE-UP
REF. FIG. 304200-PRO-00100
1. INSTALL ACCESS PANEL 211JW(2).
2. REMOVE SAFETY CLIP AND TAG AND CLOSE THE
FOLLOWING CIRCUIT BREAKERS:
- ON PANEL 122VU
1DG(2DG)
- ON PANEL 126VU
5DG(6DG).
*** CONTINUED ***
AH

30-42-00
PRO 10000-001
2-400 PAGE
2
APR 01/05

30-42-00

SWAPPING PROCEDURE OF
THERMAL SENSOR FOR
WINDSHIELD

004

PRO 10000-001
3

APR05

________________
OPERATIONAL
TEST
SEE JOB INSTRUCTION CARD
304200 OPT 10020
*****

AH

E N D

O F

T E X T

*****

30-42-00
PRO 10000-001
2-400 PAGE
3
APR 01/05

30-42-00
4

AH

CONNECTORS LOCATION

PRO 10000-001
APR05

30-42-00
PRO 10000-001

2-400

PAGE
4
APR 01/05

30-42-00

SWAPPING PROCEDURE OF
THERMAL SENSOR FOR
F/O SIDE WINDOW

PRO 10020-001
1

APR05

ZONING DATA
___________
ZONE

: 210

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

___
MEN

_________
MAN-HOURS

PUBLICATION
___________
JIC

: OPERATIONAL CHECK OF FWD


SIZE SIDE WINDOW HEATING

AH

30-42-00-OPT-10010

30-42-00
PRO 10020-001
2-400 PAGE
1
APR 01/05

30-42-00

SWAPPING PROCEDURE OF
THERMAL SENSOR FOR
F/O SIDE WINDOW

001

PRO 10020-001
2

APR05

___________
PREPARATION
REF. FIG. 304200-PRO-00120
1. OPEN SAFETY CLIP AND TAG THE FOLLOWING
CIRCUIT BREAKERS:
- ON PANEL 124VU
4DG PWR SPLY ON PRIM DC BUS2/R SIDE WINDOW
ANTI-ICING
- ON PANEL 122VU
2DG WDO HTG/AI/WSHLD R IND L/ SIDE
WDO/R CTL
- ON PANEL 122VU
29DG WDO HTG/AI/SIDE WDO/CAUTION

002

_________
PROCEDURE
REF. FIG 304200-PRO-00120
1. UNPLUG ELECTRICAL CONNECTOR 14DGA.
2. FROM CONNECTOR 14DGA DISCONNECT WIRE
CONNECTED TO PIN A AND CONNECT IT TO
PIN C.
3. PLUG ELECTRICAL CONNECTOR 14DGA.

003

________
CLOSE-UP
REF. FIG. 304200-PRO-00120
2. REMOVE SAFETY CLIP AND TAG AND CLOSE THE
FOLLOWING CIRCUIT BREAKERS:
- ON PANEL 124VU
4DG
- ON PANEL 122VU
2DG
- ON PANEL 122VU
9DG.

*** CONTINUED ***


AH

30-42-00
PRO 10020-001
2-400 PAGE
2
APR 01/05

30-42-00

SWAPPING PROCEDURE OF
THERMAL SENSOR FOR
F/O SIDE WINDOW

004

PRO 10020-001
3

APR05

________________
OPERATIONAL
TEST
REF. JIC 304200-OPT-10010
OPERATIONAL TEST OF SIDE WINDOW HEATING
*****

AH

E N D

O F

T E X T

*****

30-42-00
PRO 10020-001
2-400 PAGE
3
APR 01/05

30-42-00
4

AH

CONNECTORS LOCATION

PRO 10020-001
APR05

30-42-00
PRO 10020-001

2-400

PAGE
4
APR 01/05

30-42-11

REMOVAL AND INSTALLATION


OF WINDSHIELD
TEMPERATURE CONTROLLER

RAI 10000-001
1

MAR14

ZONING DATA
___________
ZONE
ACCESS

: 115
212
: 115BZ
811

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC

___
MEN

_________
MAN-HOURS
01

ELAPSED TIME

SPARE

: 02 WINDSHIELD TEMPERATURE
01 CONTROLLER

30-42-10-01-010

PUBLICATION
___________
JIC

: MAIN WINDSHIELD CONTROLLERS AND ASSOCIATED CIRCUITS

AH

30-42-00-OPT-10020

30-42-11
RAI 10000-001
2-400 PAGE
1
MAR 01/14

30-42-11

REMOVAL AND INSTALLATION


OF WINDSHIELD
TEMPERATURE CONTROLLER

001

RAI 10000-001
2

MAR14

___________
PREPARATION
REF. FIG. 304200-OPT-00100 (FIG.1)
304211-RAI-00100 (FIG.2)
WARNING : BEFORE UNDERTAKING MAINTENANCE WORK
ON THE AIRCRAFT DISPLAY WARNING
NOTICES PROHIBITING OPERATION ON
THE LANDING GEAR.
1. OPEN THE FOLLOWING CIRCUIT BREAKERS:
- ON PANEL 122VU (FIG.1)
1DG(2DG) WDO HTG/AI/WSHLD R IND L/SIDE
WDO/L(R) CTL
- ON PANEL 126VU (FIG.1)
5DG(6DG) L(R) WINDSHIELD HTG PWR SPLY
2. IN THE N.L.G. BAY (FIG.2):
OPEN DOOR 811 TO ACCESS TO FORWARD AVIONICS
COMPARTMENT.

002

_______
REMOVAL
REF.FIG.304211-RAI-00100
1. UNPLUG ELECTRICAL CONNECTOR(4)
2. PUT BLANKING CAP ON ELECTRICAL CONNECTOR
3. UNSCREW KNURLED FASTENER(2) SECURING WINDSHIELD TEMPERATURE CONTROLLER(1)
4. PULL CONTROLLER BY HANDLE(3) AND REMOVE IT
FROM ITS SUPPORT

003

____________
INSTALLATION
REF.FIG.304211-RAI-00100
1. CLEAN AND INSPECT COMPONENT INTERFACE AND/OR
COMPONENT ADJACENT AREA
*** CONTINUED ***
AH

30-42-11
RAI 10000-001
2-400 PAGE
2
MAR 01/14

30-42-11

REMOVAL AND INSTALLATION


OF WINDSHIELD
TEMPERATURE CONTROLLER

RAI 10000-001
3

MAR14

2. INSTALL WINDSHIELD TEMPERATURE CONTROLLER(1)


ON ITS SUPPORT
3. SECURE CONTROLLER BY KNURLED FASTENER(2).
TIGHTEN KNURLED FASTENER
4. REMOVE BLANKING CAP FROM ELECTRICAL CONNECTOR(4)
5. PLUG IN ELECTRICAL CONNECTOR
004

________
CLOSE
UP
REF.FIG.304200-OPT-00100(FIG.1) AND 304211-RAI00100(FIG.2)
1. IN THE N.L.G. BAY (FIG.2):
CLOSE ACCESS DOOR 811.
2. REMOVE SAFETY CLIPS AND TAGS AND CLOSE THE
FOLLOWING CIRCUIT BREAKERS :
- ON PANEL 122VU(FIG.1)
1DG(2DG)
- ON PANEL 126VU(FIG.1)
5DG(6DG)
WARNING : REMOVE WARNING NOTICES FOR THE
MAINTENANCE OPERATION OF LANDING
GEAR

005

________________
OPERATIONAL
TEST
SEE JOB INSTRUCTION CARD
304200 OPT 10020
*****

AH

E N D

O F

T E X T

*****

30-42-11
RAI 10000-001
2-400 PAGE
3
MAR 01/14

30-42-11
4

AH

CONTROLS AND INDICATING

RAI 10000-001
MAR14

30-42-11
RAI 10000-001

2-400

PAGE
4
MAR 01/14

30-42-11
5

AH

REM/INS OF WINDSHIELD
TEMPERATURE CONTROLLER

RAI 10000-001
MAR14

30-42-11
RAI 10000-001

2-400

PAGE
5
MAR 01/14

30-45-00

OPERATIONAL TEST OF
WINDSHIELD RAIN REMOVAL
SYSTEM

OPT 10000-001
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 120
210
: 122VU

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC

ELAPSED TIME

___
MEN

_________
MAN-HOURS
01

PUBLICATION
___________
JIC

: DC AND AC CONSTANT
FREQUENCY EXTERNAL POWER
SUPPLY

AH

24-46-00-EAD-10000

30-45-00
OPT 10000-001
2-400 PAGE
1
DEC 01/14

OPERATIONAL TEST OF
WINDSHIELD RAIN REMOVAL
SYSTEM

001

30-45-00

OPT 10000-001
2

DEC14

ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


___________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000

002

___________
PREPARATION
REF.FIG.304500-OPT-00100
1. ON PANEL 23VU(B) (22VU/C) MAKE CERTAIN THAT:
CAPT(F/O) WIPER SELECTOR SWITCH 3DB(4DB) IS
IN OFF POSITION
2. ON PANEL 122VU(A)
MAKE CERTAIN THAT THE FOLLOWING CIRCUIT
BREAKER IS CLOSED:
1DB(2DB) WIPER/CAPT(F/O)

003

________________
OPERATIONAL
TEST
REF.FIG.304500-OPT-00100
CAUTION: DO NOT OPERATE WINDSHIELD WIPERS IF
WINDSHIELD ARE DRY. WET WINDSHIELD
ABONDANTLY THROUGHOUT DURATION OF
FUNCTIONAL TESTS
MAKE SURE THAT THE RUBBER OF WIPER
BLADE IS NOT WORN
1. ON PANEL 23VU(B) (22VU/C)
A.PLACE CAPT(F/O) WIPER SELECTOR SWITCH 3DB
(4DB) IN SLOW POSITION AND VERIFY ON THE
L(R) WINDSHIELD THAT THE L(R) WIPER COVERS
80+/-8 CYCLES PER MINUTE
B.PLACE SELECTOR SWITCH 3DB(4DB) IN FAST POSITION AND VERIFY THAT THE SAME WIPER COVERS 130+/-13 CYCLES PER MINUTE

*** CONTINUED ***


AH

30-45-00
OPT 10000-001
2-400 PAGE
2
DEC 01/14

30-45-00

OPERATIONAL TEST OF
WINDSHIELD RAIN REMOVAL
SYSTEM

004

OPT 10000-001
3

DEC14

________
CLOSE
UP
REF.FIG.304500-OPT-00100
1. ON PANEL 23VU(B) (22VU/C)
PLACE CAPT(F/O) WIPER SELECTOR SWITCH 3DB
(4DB) IN OFF POSITION AND VERIFY ON THE L(R)
WINDSHIELD THAT THE L(R) WIPER RETURNS IN
THE PARK POSITION

005

DE-ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


______________________________________________
FREQUENCY NETWORK
_________________
SEE JOB INSTRUCTION CARD
244600-EAD-10000
*****

AH

E N D

O F

T E X T

*****

30-45-00
OPT 10000-001
2-400 PAGE
3
DEC 01/14

30-45-00
4

AH

CONTROLS AND INDICATING

OPT 10000-001
DEC14

30-45-00
OPT 10000-001

2-400

PAGE
4
DEC 01/14

30-45-11

REMOVAL AND INSTALLATION


OF WIPER MOTOR

RAI 10000-001
1

MAR15

ZONING DATA
___________
ZONE
ACCESS

: 110
115
713
714
: 115BZ

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC
MECHANIC

___
MEN

_________
MAN-HOURS
01
01

ELAPSED TIME

SPARE

: 01 WIPER MOTOR L
01 WIPER MOTOR R

30-45-10-05-080
30-45-10-05-090

: REMOVAL AND INSTALLATION


OF WIPER ARM
: WINDSHIELD RAIN REMOVAL
OPERATIONAL TEST

30-45-12-RAI-10000

PUBLICATION
___________
JIC
JIC

AH

30-45-00-OPT-10000

30-45-11
RAI 10000-001
2-400 PAGE
1
MAR 01/15

30-45-11

REMOVAL AND INSTALLATION


OF WIPER MOTOR

001

R
R

RAI 10000-001
2

MAR15

____________________
REMOVAL
OF WIPER ARM
SEE JOB INSTRUCTION CARD
304512-RAI-10000

002

___________
PREPARATION
REF.FIG.304511-RAI-00100
WARNING: BEFORE UNDERTAKING MAINTENANCE WORK
ON THE AIRCRAFT DISPLAY WARNING NOTICES PROHIBITING OPERATION ON THE LANDING GEAR
1. IN THE N.L.G. BAY
OPEN DOOR 115BZ TO ACCESS TO FORWARD AVIONICS COMPARTMENT

003

_______
REMOVAL
REF.FIG.304511-RAI-00100
1. UNPLUG ELECTRICAL CONNECTOR(1)
2. PUT BLANKING CAP ON ELECTRICAL CONNECTOR
3. REMOVE FOUR BOLT(2) SECURING L(R) WIPER
MOTOR(3)
4. REMOVE L(R) WIPER MOTOR

004

____________
INSTALLATION
REF.FIG.304511-RAI-00100
1. INSTALL L(R) WIPER MOTOR(3)
2. INSTALL FOUR BOLTS(2). TIGHTEN BOLTS
3. REMOVE BLANKING CAP FROM ELECTRICAL CONNECTOR(1)
*** CONTINUED ***
AH

30-45-11
RAI 10000-001
2-400 PAGE
2
MAR 01/15

30-45-11

REMOVAL AND INSTALLATION


OF WIPER MOTOR

RAI 10000-001
3

MAR15

4. PLUG IN ELECTRICAL CONNECTOR


005

________
CLOSE
UP
REF.FIG.304511-RAI00100
1. IN THE N.L.G. BAY
CLOSE ACCESS DOOR 115BZ
2. REMOVE WARNING NOTICES FOR THE LANDING GEAR
OPERATION

006

_________________________
INSTALLATION
OF WIPER ARM
REFER TO JIC 304512 RAI 10000

007

________________
OPERATIONAL
TEST
SEE JOB INSTRUCTION CARD
304500 OPT 10000
*****

AH

E N D

O F

T E X T

*****

30-45-11
RAI 10000-001
2-400 PAGE
3
MAR 01/15

30-45-11
4

AH

REM/INS OF L(R)
MOTOR WIPER

RAI 10000-001
MAR15

30-45-11
RAI 10000-001

2-400

PAGE
4
MAR 01/15

30-45-12

REMOVAL AND INSTALLATION


OF WIPER ARM

RAI 10000-001
1

APR05

ZONING DATA
___________

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC

___
MEN

_________
MAN-HOURS
01

ELAPSED TIME

SPARE

: 01 L WIPER ARM
01 R WIPER ARM

30-45-10-05-020
30-45-10-05-030

EXPENDABLE

: 01 O-RING

30-45-10-05-070

: WIPER BLADE ADJUSTMENT

30-45-14-ADJ-10000

PUBLICATION
___________
JIC

AH

30-45-12
RAI 10000-001
2-400 PAGE
1
APR 01/05

30-45-12

REMOVAL AND INSTALLATION


OF WIPER ARM

001

RAI 10000-001
2

APR05

___________
PREPARATION
REF.FIG.304512-RAI-00100
1. ON PANEL 122VU (A)
OPEN THE FOLLOWING CIRCUIT BREAKER:
1DB(2DB) WIPERS/CAPT(F/O)
2. POSITION ACCESS PLATFORM TO L(R) WINDSHIELD

002

_________________
WIPER
ARM REMOVAL
REF. FIG. 304512-RAI-00100
NOTE: NEVER PULL THE WIPER ARM TO AVOID SPRING
DAMAGES.
1. UNSCREW SCREW (6) TO CANCEL THE PRESSURE OF
THE ARM ON THE WINDSHIELD.
2. CUT AND REMOVE LOCKWIRE (1), REMOVE BOLT (2)
AND WASHER (3) SECURING THE WIPER ARM (5) TO
OUTPUT SHAFT (4) OF WIPER MOTOR.
3. REMOVE WIPER ARM.

003

______________________
WIPER
ARM INSTALLATION
REF.FIG.304512-RAI-00100
NOTE:THE WIPER ARM MUST BE INSTALLED IN THE
PARKING POSITION
1. INSTALL WIPER ARM (5)
2. INSTALL WASHER (3) AND BOLT (2).
TIGHTEN BOLT AND WIRELOCK

*** CONTINUED ***


AH

30-45-12
RAI 10000-001
2-400 PAGE
2
APR 01/05

30-45-12

REMOVAL AND INSTALLATION


OF WIPER ARM

004

RAI 10000-001
3

APR05

______________________
WIPER
BLADE ADJUSTMENT
SEE JOB INSTRUCTION CARD
304514-ADJ-10000

005

________
CLOSE
UP
REF. FIG. 304512-RAI-00100
1. REMOVE ACCESS PLATFORM.
2. ON PANEL 122VU,
REMOVE SAFETY CLIP AND TAG AND CLOSE THE
FOLLOWING CIRCUIT BREAKER :
1DB(2DB)
*****

AH

E N D

O F

T E X T

*****

30-45-12
RAI 10000-001
2-400 PAGE
3
APR 01/05

30-45-12
4

AH

WIPER ARM REM/INS

RAI 10000-001
APR05

30-45-12
RAI 10000-001

2-400

PAGE
4
APR 01/05

30-45-14

WIPER BLADE ADJUSTMENT

ADJ 10000-001
1

APR05

ZONING DATA
___________

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC

ELAPSED TIME

___
MEN

_________
MAN-HOURS
01

PUBLICATION
___________
JIC

: WINDSHIELD RAIN REMOVAL


OPERATIONAL TEST

AH

30-45-00-OPT-10000

30-45-14
ADJ 10000-001
2-400 PAGE
1
APR 01/05

30-45-14

WIPER BLADE ADJUSTMENT

ADJ 10000-001
2

001

APR05

___________
PREPARATION
REF.FIG.304512-RAI-00100
1. ON PANEL 122VU (A)
OPEN THE FOLLOWING CIRCUIT BREAKER:
1DB(2DB) WIPERS/CAPT(F/O)
2. POSITION ACCESS PLATFORM TO L(R) WINDSHIELD

002

__________
ADJUSTMENT
REF. FIG. 304500-ADJ-00100
NOTE: DO NOT REMOVE THE WIPER BLADE FROM L(R)
WINDSHIELD.
NOTE: NEVER PULL THE LEVER ARM TO AVOID SPRING
DAMAGES.
1. PLACE LOCKWIRE AT THE COUPLING POINT BETWEEN
WIPER ARM AND WIPER BLADE.
2. HOOK A DYNAMOMETER TO LOCKWIRE FOR THE MEASURING OF THE STREGTH TO BE APPLIED TO WIPER
BLADE ON THE WINDSHIELD.
3. ADJUST THE WIPER BLADE STRENGTH BY TIGHTINING THE SCREW (1) AT THE BOTTOM OF THE
WIPER ARM TO OBTAIN AFTER THE DISJUNCTION OF
THE WIPER BLADE FROM THE WINDSHIELD, A WIPER
BLADE STRENGTH OF 3.5+0.2/-0 KG (7.868 LB).
4. REMOVE THE DYNAMOMETER FROM LOCKWIRE AND CUT
THIS ONE.
NOTE: CLEAN AND WET THE WINDSHIELD ACCURATELY
AND UNIFORMLY BEFORE OF THE OPERATIONAL
TEST.

*** CONTINUED ***


AH

30-45-14
ADJ 10000-001
2-400 PAGE
2
APR 01/05

30-45-14

WIPER BLADE ADJUSTMENT

ADJ 10000-001
3

003

APR05

________
CLOSE
UP
REF. FIG. 304512-RAI-00100
1. REMOVE ACCESS PLATFORM.
2. ON PANEL 122VU,
REMOVE SAFETY CLIP AND TAG AND CLOSE THE
FOLLOWING CIRCUIT BREAKER :
1DB(2DB)

004

________________
OPERATIONAL
TEST
SEE JOB INSTRUCTION CARD
304500 OPT 10000
*****

AH

E N D

O F

T E X T

*****

30-45-14
ADJ 10000-001
2-400 PAGE
3
APR 01/05

30-45-14
4

AH

WIPER ARM REM/INS

ADJ 10000-001
APR05

30-45-14
ADJ 10000-001

2-400

PAGE
4
APR 01/05

30-45-14
5

AH

WIPER BLADE
ADJUSTMENT

ADJ 10000-001
APR05

30-45-14
ADJ 10000-001

2-400

PAGE
5
APR 01/05

30-45-14

REMOVAL AND INSTALLATION


OF WIPER BLADE

RAI 10000-001
1

APR05

ZONING DATA
___________

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELECTRIC
MECHANIC

_________
MAN-HOURS
01
01

ELAPSED TIME

SPARE

: 01 WIPER BLADE L(R)

30-45-10-05-010

: WIPER BLADE ADJUSTMENT


: WINDSHIELD RAIN REMOVAL
OPERATIONAL TEST

30-45-14-ADJ-10000
30-45-00-OPT-10000

PUBLICATION
___________
JIC
JIC

AH

30-45-14
RAI 10000-001
2-400 PAGE
1
APR 01/05

30-45-14

REMOVAL AND INSTALLATION


OF WIPER BLADE

001

RAI 10000-001
2

APR05

___________
PREPARATION
REF.FIG.304512-RAI-00100
1. ON PANEL 122VU (A)
OPEN THE FOLLOWING CIRCUIT BREAKER:
1DB(2DB) WIPERS/CAPT(F/O)
2. POSITION ACCESS PLATFORM TO L(R) WINDSHIELD

002

___________________
WIPER
BLADE REMOVAL
REF. FIG. 304514-RAI-00100
NOTE: NEVER PULL WIPER ARM TO AVOID SPRING
DAMAGES.
NOTE: IF THE WIPER ARM HAS BEEN REMOVED, YOU
BEGIN THE REMOVAL FROM POINT 3; IF THE
WIPER ARM HAS NOT BEEN REMOVED, YOU
REMOVES THE WIPER BLADE AS FOLLOWS :
1. UNSCREW SCREW (6) TO CANCEL THE PRESSURE OF
THE ARM ON THE WINDSHIELD.
2. PULL WIPER ARM (1) FROM L(R) WINDSHIELD.
3. REMOVE SCREW (2) RETAINING WIPER BLADE (3).
4. REMOVE WIPER BLADE.

003

________________________
WIPER
BLADE INSTALLATION
REF. FIG. 304514-RAI-00100
1. INSTALL WIPER BLADE (3) AS THE ARROW SHOWS.
2. TIGHTEN SCREW (2).
3. PUT WIPER ARM (1) ON L(R) WINDSHIELD. (ONLY
IN CASE THAT WIPER ARM WAS NOT REMOVED).
*** CONTINUED ***
AH

30-45-14
RAI 10000-001
2-400 PAGE
2
APR 01/05

30-45-14

REMOVAL AND INSTALLATION


OF WIPER BLADE

004

RAI 10000-001
3

APR05

______________________
WIPER
BLADE ADJUSTMENT
SEE JOB INSTRUCTION CARD
304514-ADJ-10000

005

________
CLOSE
UP
REF. FIG. 304512-RAI-00100
1. REMOVE ACCESS PLATFORM.
2. ON PANEL 122VU,
REMOVE SAFETY CLIP AND TAG AND CLOSE THE
FOLLOWING CIRCUIT BREAKER :
1DB(2DB)

006

________________
OPERATIONAL
TEST
SEE JOB INSTRUCTION CARD
304500 OPT 10000
*****

AH

E N D

O F

T E X T

*****

30-45-14
RAI 10000-001
2-400 PAGE
3
APR 01/05

30-45-14
4

AH

WIPER ARM REM/INS

RAI 10000-001
APR05

30-45-14
RAI 10000-001

2-400

PAGE
4
APR 01/05

30-45-14
5

AH

WIPER BLADE REM/INS

RAI 10000-001
APR05

30-45-14
RAI 10000-001

2-400

PAGE
5
APR 01/05

30-61-00

OPERATIONAL TEST OF
PROPELLERS ANTI-ICING
SYSTEM

OPT 10010-003
1

DEC14

ZONING DATA
___________
ZONE

: 210

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

___
MEN

_________
MAN-HOURS

PUBLICATION
___________
JIC
JIC
JIC

: READING OF MFC
MAINTENANCE MEMORY
: ERASURE OF MFC
MAINTENANCE MEMORY
: ENGINE START (PROPELLER
BRAKE RELEASED) USING
DC GROUND POWER UNIT

AH

45-13-00-RDG-10000
45-13-00-RON-10000
72-00-00-ERU-10030

30-61-00
OPT 10010-003
2-400 PAGE
1
DEC 01/14

30-61-00

OPERATIONAL TEST OF
PROPELLERS ANTI-ICING
SYSTEM

001

OPT 10010-003
2

DEC14

_________________________________
READING
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RDG-10000

002

_________________________________
ERASURE
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RON-10000
NOTE:THIS TASK MUST BE PERFORMED ONLY IF FAULTS
RELATIVE TO THE SYSTEM TO BE CHECKED HAVE
BEEN RECORDED BY THE MFC MAINTENANCE
MEMORY.

003

_________________________
ENGINE
GROUND IDLE RUN-UP
SEE JOB INSTRUCTION CARD
720000-ERU-10030

004

PRECAUTIONARY MEASURES BEFORE PROPELLER


_______________________________________
ANTI-ICING SYSTEM OPERATIONAL TEST
__________________________________
IN ORDER TO AVOID ANY OIL SMELL OR SMOKE IN
THE CABIN, IT IS RECOMMENDED TO PERFORM THIS
TEST WITH BLEED OFF SELECTED.

005

______________________
DEACTIVATION
OF MFC 1B
1. ON PANEL 25VU, RELEASE THE FOLLOWING
PUSHBUTTON SWITCH
6UA1

MFC/1B/FAULT/OFF

2. ON PANEL 25VU, MAKE CERTAIN THAT FOLLOWING


LEGEND IS ON:
MFC 1B OFF

*** CONTINUED ***


AH

30-61-00
OPT 10010-003
2-400 PAGE
2
DEC 01/14

30-61-00

OPERATIONAL TEST OF
PROPELLERS ANTI-ICING
SYSTEM

006

OPT 10010-003
3

DEC14

______________________
DEACTIVATION
OF MFC 2B
1. ON PANEL 25VU, RELEASE THE FOLLOWING
PUSHBUTTON SWITCH
6UA2

MFC/2B/FAULT/OFF

2. ON PANEL 25VU, MAKE CERTAIN THAT FOLLOWING


LEGEND IS ON:
MFC 2B OFF
007

OPERATIONAL TEST OF PROPELLER ANTI-ICING


_________________________________________
SYSTEM
______
CAUTION: THIS TEST IS PERFORMED WITH THE 2
ENGINES OPERATING AT MORE THAN
63%+/-2% OF NP.
THE STATIC TEST IS NOT AUTHORIZED:
RISK OF IMPORTANT DETERIORATION OF
PROPELLER BLADES.
REF. FIG. 306100-OPT-00110
REF. FIG. 306100-OPT-00120
1. ON PANEL 24VU,
A. PRESS MODE SEL/AUTO PUSHBUTTON
SWITCH (5):
- FAULT LEGENDS OFF,
- MAN LEGENDS ON.
B. CHECK THAT PROP MODE SEL PUSHBUTTON
SWITCH (3) IS RELEASED (OUT):
- ON LEGEND OFF.
C. PRESS PROP1 AND PROP2 PUSHBUTTON
SWITCHES (1) AND (2):
- FAULT LEGENDS OFF,
- ON LEGENDS ON.
*** CONTINUED ***
AH

30-61-00
OPT 10010-003
2-400 PAGE
3
DEC 01/14

30-61-00

OPERATIONAL TEST OF
PROPELLERS ANTI-ICING
SYSTEM

OPT 10010-003
4

DEC14

2. WAIT A COMPLETE DE-ICING CYCLE I.E. 50 SEC.


NO WARNING MUST APPEAR.
3. ON PANEL 24VU,
PRESS PROP MODE SEL PUSHBUTTON SWITCH (3):
- ON LEGEND ON.
4. WAIT A COMPLETE DE-ICING CYCLE I.E. 83 SEC.
NO WARNING MUST APPEAR.
5. ON PANEL 24VU,
A. RELEASE PROP MODE SEL PUSHBUTTON
SWITCH (3) :
- ON LEGEND OFF.
B. RELEASE PROP1 AND PROP2 PUSHBUTTON
SWITCHES (1) AND (2):
- FAULT LEGENDS OFF,
- ON LEGENDS OFF.
WARNING: IF ENGINES ARE RUNNING AT LESS
THAN 63%+/-2% OF NP, PERFORM
TEST BY PRESSING PROP A/ICING/
PTT TEST SWITCH (4) LOCATED ON
ON PANEL 702VU.
THE TEST MUST NOT EXCEED 160 SEC.
008

____________________
ACTIVATION
OF MFC 1B
1. ON PANEL 25VU, PRESS THE FOLLOWING
PUSHBUTTON SWITCH:
6UA1

MFC/1B/FAULT/OFF

2. ON PANEL 25VU, MAKE CERTAIN THAT FOLLOWING


LEGEND IS OFF.
MFC 1B FAULT OFF

*** CONTINUED ***


AH

30-61-00
OPT 10010-003
2-400 PAGE
4
DEC 01/14

30-61-00

OPERATIONAL TEST OF
PROPELLERS ANTI-ICING
SYSTEM

009

OPT 10010-003
5

DEC14

____________________
ACTIVATION
OF MFC 2B
1. ON PANEL 25VU, PRESS THE FOLLOWING
PUSHBUTTON SWITCH:
6UA2

MFC/2B/FAULT/OFF

2. ON PANEL 25VU, MAKE CERTAIN THAT FOLLOWING


LEGEND IS OFF.
MFC 2B FAULT OFF
010

______________________
DEACTIVATION
OF MFC 1A
1. ON PANEL 25VU, RELEASE THE FOLLOWING
PUSHBUTTON SWITCH:
7UA1

MFC/1A/FAULT/OFF

2. ON PANEL 25VU, MAKE CERTAIN THAT FOLLOWING


LEGEND IS ON:
MFC/1A/OFF
011

______________________
DEACTIVATION
OF MFC 2A
1. ON PANEL 25VU, RELEASE THE FOLLOWING
PUSHBUTTON SWITCH
7UA2

MFC/2A/FAULT/OFF

2. ON PANEL 25VU, MAKE CERTAIN THAT FOLLOWING


LEGEND IS ON:
MFC 2A OFF
012

OPERATIONAL TEST OF PROPELLER ANTI-ICING


_________________________________________
SYSTEM
______
CAUTION: THIS TEST IS PERFORMED WITH THE 2
ENGINES OPERATING AT MORE THAN
*** CONTINUED ***
AH

30-61-00
OPT 10010-003
2-400 PAGE
5
DEC 01/14

30-61-00

OPERATIONAL TEST OF
PROPELLERS ANTI-ICING
SYSTEM

OPT 10010-003
6

DEC14

63%+/-2% OF NP.
THE STATIC TEST IS NOT AUTHORIZED:
RISK OF IMPORTANT DETERIORATION OF
PROPELLER BLADES.
REF. FIG. 306100-OPT-00110
REF. FIG. 306100-OPT-00120
1. ON PANEL 24VU,
A. PRESS PROP1 AND PROP2 PUSHBUTTON
SWITCHES (1) AND (2):
- FAULT LEGENDS OFF,
- ON LEGENDS ON.
B. CHECK THAT PROP MODE SEL PUSHBUTTON
SWITCH (3) IS RELEASED (OUT):
- ON LEGEND OFF.
2. WAIT A COMPLETE DE-ICING CYCLE I.E. 50 SEC.
NO WARNING MUST APPEAR.
3. ON PANEL 24VU,
PRESS PROP MODE SEL PUSHBUTTON SWITCH (3):
- ON LEGEND ON.
4. WAIT A COMPLETE DE-ICING CYCLE I.E. 83 SEC.
NO WARNING MUST APPEAR.
WARNING: IF ENGINES ARE RUNNING AT LESS
THAN 63%+/-2% OF NP, PERFORM
TEST BY PRESSING PROP A/ICING/
PTT TEST SWITCH (4) LOCATED ON
PANEL 702VU.
THE TEST MUST NOT EXCEED 160 SEC.
013

____________________
ACTIVATION
OF MFC 1A
1. ON PANEL 25VU, PRESS THE FOLLOWING
PUSHBUTTON SWITCH:
*** CONTINUED ***
AH

30-61-00
OPT 10010-003
2-400 PAGE
6
DEC 01/14

30-61-00

OPERATIONAL TEST OF
PROPELLERS ANTI-ICING
SYSTEM

7UA1

OPT 10010-003
7

DEC14

MFC/1A/FAULT/OFF

2. ON PANEL 25VU, MAKE CERTAIN THAT FOLLOWING


LEGENDS ARE OFF:
MFC/1A/FAULT/OFF
014

____________________
ACTIVATION
OF MFC 2A
1. ON PANEL 25VU, PRESS THE FOLLOWING
PUSHBUTTON SWITCH:
7UA2

MFC/2A/FAULT/OFF

2. ON PANEL 25VU, MAKE CERTAIN THAT FOLLOWING


LEGEND IS OFF.
MFC 2A FAULT OFF
015

OPERATIONAL TEST OF PROPELLER ANTI-ICING


________________________________________
AND ASSOCIATED WARNING
______________________
REF. FIG. 306100-OPT-00110
1. ON PANEL 126VU, OPEN THE FOLLOWING CIRCUIT
BREAKER:
25DH
PROP1/ANTI-ICING/PWR SPLY
2. ON PANEL 24VU, ON PROP1 PUSHBUTTON
SWITCH (1):
- FAULT LEGEND COMES ON TWICE IN 20 SEC.
- ON LEGEND ON.
3. THE FOLLOWING WARNINGS APPEAR SIMULTANEOUSLY:
- ANTI-ICING ANNUNCIATOR COMES ON CAP,
- CAUTION ANNUNCIATORS COME ON,
- SINGLE CHIME SOUNDS.
NOTE: AFTER 150 SEC. FAULT LEGEND OF
PROP1 PUSHBUTTON SWITCH (1) REMAINS
*** CONTINUED ***
AH

30-61-00
OPT 10010-003
2-400 PAGE
7
DEC 01/14

30-61-00

OPERATIONAL TEST OF
PROPELLERS ANTI-ICING
SYSTEM

OPT 10010-003
8

DEC14

ON AS WELL AS THE ASSOCIATED WARNINGS.


4. CLOSE CIRCUIT BREAKER 25DH.
5. ON PANEL 24VU, ON PROP1 PUSHBUTTON
SWITCH (1):
- FAULT LEGEND OFF,
- ON LEGEND ON.
6. WARNINGS DISAPPEAR.
NOTE: TAKE UP THIS TEST WITH CIRCUIT BREAKER
ON PANEL 126VU OPENED:
2DH
PROP2/ANTI-ICING/PWR SPLY
AND ON PANEL 24VU WITH PROP2
PUSHBUTTON SWITCH (2) PRESSED.
7. ON PANEL 24VU,
A. RELEASE PROP MODE SEL PUSHBUTTON
SWITCH (3):
- ON LEGEND OFF,
B. RELEASE MODE SEL/AUTO PUSHBUTTON
SWITCH (5):
- FAULT LEGENDS OFF,
- MAN LEGEND OFF.
C. RELEASE PROP1 AND PROP2 PUSHBUTTON
SWITCHES (1) AND (2):
- FAULT LEGENDS OFF,
- ON LEGENDS OFF.
NOTE: BY MEANS OF THE PROCEDURE BELOW MAKE
SURE THAT THE FOLLOWING FAILURES ARE
MEMORIZED IN MISCELLANEOUS 2 MFC
MAINTENANCE MEMORY:
- ANTI-ICE: LEFT PROPELLER HEATER FAULT
- ANTI-ICE: RIGHT PROPELLER HEATER FAULT

*** CONTINUED ***


AH

30-61-00
OPT 10010-003
2-400 PAGE
8
DEC 01/14

30-61-00

OPERATIONAL TEST OF
PROPELLERS ANTI-ICING
SYSTEM

016

OPT 10010-003
9

DEC14

______________________________________
SHUT
DOWN OF ENGINE GROUND IDLE RUN-UP
SEE JOB INSTRUCTION CARD
720000-ERU-10030

017

_________________________________
READING
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RDG-10000

018

_________________________________
ERASURE
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RON-10000
*****

AH

E N D

O F

T E X T

*****

30-61-00
OPT 10010-003
2-400 PAGE
9
DEC 01/14

30-61-00
10

AH

CONTROLS AND INDICATING


OF PROPELLER ANTI ICING

OPT 10010-003
DEC14

30-61-00
OPT 10010-003

2-400

PAGE
10
DEC 01/14

30-61-00
11

AH

OPERATIONAL TEST OF
PROPELLER ANTI-ICING
SYSTEM

OPT 10010-003
DEC14

30-61-00
OPT 10010-003

2-400

PAGE
11
DEC 01/14

30-61-00

OPERATIONAL TEST OF
PROPELLERS ANTI-ICING
SYSTEM

OPT 10010-004
1

DEC14

ZONING DATA
___________
ZONE

: 210

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

___
MEN

_________
MAN-HOURS

PUBLICATION
___________
JIC
JIC
JIC
JIC

: PRINCIPLE OF CDS USE


(DISPLAY UNITS
EXPLORATION)
: READING OF MFC
MAINTENANCE MEMORY
: ERASURE OF MFC
MAINTENANCE MEMORY
: ENGINE START (PROPELLER
BRAKE RELEASED) USING
DC GROUND POWER UNIT

AH

31-63-00-PRO-10000
45-13-00-RDG-10000
45-13-00-RON-10000
72-00-00-ERU-10030

30-61-00
OPT 10010-004
2-400 PAGE
1
DEC 01/14

30-61-00

OPERATIONAL TEST OF
PROPELLERS ANTI-ICING
SYSTEM

001

OPT 10010-004
2

DEC14

PRINCIPLE OF CDS USE (DISPLAY UNITS


___________________________________
EXPLORATION)
____________
(TO USE ONLY IF NEEDED)
_______________________
SEE JOB INSTRUCTION CARD
316300-PRO-10000
NOTE: PROCEDURE TO USE ONLY IF NEEDED.
THIS PROCEDURE DESCRIBES LOCATION AND
MANAGEMENT OF THE DIFFERENT DISPLAY
WINDOWS PROVIDED BY THE THREE FORMATS
(PFD, EWD, MFD) PROPOSED ON THE FIVE
DISPLAY UNITS (DU).

002

_________________________________
READING
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RDG-10000

003

_________________________________
ERASURE
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RON-10000
NOTE:THIS TASK MUST BE PERFORMED ONLY IF FAULTS
RELATIVE TO THE SYSTEM TO BE CHECKED HAVE
BEEN RECORDED BY THE MFC MAINTENANCE
MEMORY.

004

_________________________
ENGINE
GROUND IDLE RUN-UP
SEE JOB INSTRUCTION CARD
720000-ERU-10030

005

PRECAUTIONARY MEASURES BEFORE PROPELLER


_______________________________________
ANTI-ICING SYSTEM OPERATIONAL TEST
__________________________________
IN ORDER TO AVOID ANY OIL SMELL OR SMOKE IN
THE CABIN, IT IS RECOMMENDED TO PERFORM THIS
TEST WITH BLEED OFF SELECTED.
*** CONTINUED ***
AH

30-61-00
OPT 10010-004
2-400 PAGE
2
DEC 01/14

30-61-00

OPERATIONAL TEST OF
PROPELLERS ANTI-ICING
SYSTEM

006

OPT 10010-004
3

DEC14

______________________
DEACTIVATION
OF MFC 1B
1. ON PANEL 25VU, RELEASE THE FOLLOWING
PUSHBUTTON SWITCH
6UA1

MFC/1B/FAULT/OFF

2. ON PANEL 25VU, MAKE CERTAIN THAT FOLLOWING


LEGEND IS ON:
MFC 1B OFF
007

______________________
DEACTIVATION
OF MFC 2B
1. ON PANEL 25VU, RELEASE THE FOLLOWING
PUSHBUTTON SWITCH
6UA2

MFC/2B/FAULT/OFF

2. ON PANEL 25VU, MAKE CERTAIN THAT FOLLOWING


LEGEND IS ON:
MFC 2B OFF
008

OPERATIONAL TEST OF PROPELLER ANTI-ICING


_________________________________________
SYSTEM
______
CAUTION: THIS TEST IS PERFORMED WITH THE 2
ENGINES OPERATING AT MORE THAN
63%+/-2% OF NP.
THE STATIC TEST IS NOT AUTHORIZED:
RISK OF IMPORTANT DETERIORATION OF
PROPELLER BLADES.
REF. FIG. 306100-OPT-00110
REF. FIG. 306100-OPT-00120
1. ON PANEL 24VU,
A. PRESS MODE SEL/AUTO PUSHBUTTON
SWITCH (5):
*** CONTINUED ***
AH

30-61-00
OPT 10010-004
2-400 PAGE
3
DEC 01/14

30-61-00

OPERATIONAL TEST OF
PROPELLERS ANTI-ICING
SYSTEM

OPT 10010-004
4

DEC14

- FAULT LEGENDS OFF,


- MAN LEGENDS ON.
B. CHECK THAT PROP MODE SEL PUSHBUTTON
SWITCH (3) IS RELEASED (OUT):
- ON LEGEND OFF.
C. PRESS PROP1 AND PROP2 PUSHBUTTON
SWITCHES (1) AND (2):
- FAULT LEGENDS OFF,
- ON LEGENDS ON.
ON MFD, IN TEMPORARY SELECTION WINDOW,
CYAN 1 PROP 2 MESSAGE IS DISPLAYED.
2. WAIT A COMPLETE DE-ICING CYCLE I.E. 50 SEC.
NO WARNING MUST APPEAR.
3. ON PANEL 24VU,
PRESS PROP MODE SEL PUSHBUTTON SWITCH (3):
- ON LEGEND ON.
4. WAIT A COMPLETE DE-ICING CYCLE I.E. 83 SEC.
NO WARNING MUST APPEAR.
5. ON PANEL 24VU,
A. RELEASE PROP MODE SEL PUSHBUTTON
SWITCH (3):
- ON LEGEND OFF.
B. RELEASE PROP1 AND PROP2 PUSHBUTTON
SWITCHES (1) AND (2):
- FAULT LEGENDS OFF,
- ON LEGENDS OFF.
ON MFD, IN TEMPORARY SELECTION WINDOW,
1 PROP 2 MESSAGE DISAPPEARS.
WARNING: IF ENGINES ARE RUNNING AT LESS
THAN 63%+/-2% OF NP, PERFORM
TEST BY PRESSING PROP A/ICING/
PTT TEST SWITCH (4)
*** CONTINUED ***
AH

30-61-00
OPT 10010-004
2-400 PAGE
4
DEC 01/14

30-61-00

OPERATIONAL TEST OF
PROPELLERS ANTI-ICING
SYSTEM

OPT 10010-004
5

DEC14

LOCATED ON PANEL 702VU.


THE TEST MUST NOT EXCEED 160 SEC.
009

____________________
ACTIVATION
OF MFC 1B
1. ON PANEL 25VU, PRESS THE FOLLOWING
PUSHBUTTON SWITCH:
6UA1

MFC/1B/FAULT/OFF

2. ON PANEL 25VU, MAKE CERTAIN THAT FOLLOWING


LEGEND IS OFF.
MFC 1B FAULT OFF
010

____________________
ACTIVATION
OF MFC 2B
1. ON PANEL 25VU, PRESS THE FOLLOWING
PUSHBUTTON SWITCH:
6UA2

MFC/2B/FAULT/OFF

2. ON PANEL 25VU, MAKE CERTAIN THAT FOLLOWING


LEGEND IS OFF.
MFC 2B FAULT OFF
011

______________________
DEACTIVATION
OF MFC 1A
1. ON PANEL 25VU, RELEASE THE FOLLOWING
PUSHBUTTON SWITCH:
7UA1

MFC/1A/FAULT/OFF

2. ON PANEL 25VU, MAKE CERTAIN THAT FOLLOWING


LEGEND IS ON:
MFC/1A/OFF

*** CONTINUED ***


AH

30-61-00
OPT 10010-004
2-400 PAGE
5
DEC 01/14

30-61-00

OPERATIONAL TEST OF
PROPELLERS ANTI-ICING
SYSTEM

012

OPT 10010-004
6

DEC14

______________________
DEACTIVATION
OF MFC 2A
1. ON PANEL 25VU, RELEASE THE FOLLOWING
PUSHBUTTON SWITCH
7UA2

MFC/2A/FAULT/OFF

2. - ON PANEL 25VU, MAKE CERTAIN THAT FOLLOWING


LEGEND IS ON:
MFC 2A OFF
- ON EWD, IN ALERT WINDOW, MFC 2A MESSAGE
IS DISPLAYED.
013

OPERATIONAL TEST OF PROPELLER ANTI-ICING


_________________________________________
SYSTEM
______
CAUTION: THIS TEST IS PERFORMED WITH THE 2
ENGINES OPERATING AT MORE THAN
63%+/-2% OF NP.
THE STATIC TEST IS NOT AUTHORIZED:
RISK OF IMPORTANT DETERIORATION OF
PROPELLER BLADES.
REF. FIG. 306100-OPT-00110
REF. FIG. 306100-OPT-00120
1. ON PANEL 24VU,
A. PRESS PROP1 AND PROP2 PUSHBUTTON
SWITCHES (1) AND (2):
- FAULT LEGENDS OFF,
- ON LEGENDS ON.
ON MFD, IN TEMPORARY SELECTION WINDOW,
CYAN 1 PROP 2 MESSAGE IS DISPLAYED.
B. CHECK THAT PROP MODE SEL PUSHBUTTON
SWITCH (3) IS RELEASED (OUT):
- ON LEGEND OFF.
*** CONTINUED ***
AH

30-61-00
OPT 10010-004
2-400 PAGE
6
DEC 01/14

30-61-00

OPERATIONAL TEST OF
PROPELLERS ANTI-ICING
SYSTEM

OPT 10010-004
7

DEC14

2. WAIT A COMPLETE DE-ICING CYCLE I.E. 50 SEC.


NO WARNING MUST APPEAR.
3. ON PANEL 24VU,
PRESS PROP MODE SEL PUSHBUTTON SWITCH (3):
- ON LEGEND ON.
4. WAIT A COMPLETE DE-ICING CYCLE I.E. 83 SEC.
NO WARNING MUST APPEAR.
WARNING: IF ENGINES ARE RUNNING AT LESS
THAN 63%+/-2% OF NP, PERFORM
TEST BY PRESSING PROP A/ICING/
PTT TEST SWITCH (4) LOCATED
ON PANEL 702VU.
THE TEST MUST NOT EXCEED 160 SEC.
014

____________________
ACTIVATION
OF MFC 1A
1. ON PANEL 25VU, PRESS THE FOLLOWING
PUSHBUTTON SWITCH:
7UA1

MFC/1A/FAULT/OFF

2. ON PANEL 25VU, MAKE CERTAIN THAT FOLLOWING


LEGENDS ARE OFF:
MFC/1A/FAULT/OFF
015

____________________
ACTIVATION
OF MFC 2A
1. ON PANEL 25VU, PRESS THE FOLLOWING
PUSHBUTTON SWITCH:
7UA2

MFC/2A/FAULT/OFF

2. - ON PANEL 25VU, MAKE CERTAIN THAT FOLLOWING


LEGEND IS OFF.
MFC 2A FAULT OFF
*** CONTINUED ***
AH

30-61-00
OPT 10010-004
2-400 PAGE
7
DEC 01/14

30-61-00

OPERATIONAL TEST OF
PROPELLERS ANTI-ICING
SYSTEM

OPT 10010-004
8

DEC14

- ON EWD, IN ALERT WINDOW, MFC 2A MESSAGE


DISAPPEARS.
016

OPERATIONAL TEST OF PROPELLER ANTI-ICING


________________________________________
AND ASSOCIATED WARNING
______________________
REF. FIG. 306100-OPT-00110
1. ON PANEL 126VU, OPEN THE FOLLOWING CIRCUIT
BREAKER:
25DH
PROP1/ANTI-ICING/PWR SPLY
2. ON PANEL 24VU, ON PROP1 PUSHBUTTON
SWITCH (1):
- FAULT LEGEND COMES ON TWICE IN 20 SEC.
- ON LEGEND ON.
ON MFD, IN TEMPORARY SELECTION WINDOW,
1 PROP MESSAGE BECOMES AMBER TWICE IN
20 SEC.
3. THE FOLLOWING WARNINGS APPEAR SIMULTANEOUSLY:
- ON EWD, IN ALERT WINDOW, A-ICING PROP
MESSAGE IS DISPLAYED,
- MASTER CAUTION ANNUNCIATORS COME ON,
- SINGLE CHIME SOUNDS.
NOTE: AFTER 150 SEC. FAULT LEGEND OF
PROP1 PUSHBUTTON SWITCH (1) REMAINS
ON AS WELL AS THE ASSOCIATED WARNINGS.
(SAME LOGIC WITH 1 PROP MESSAGE ON
MFD)
4. CLOSE CIRCUIT BREAKER 25DH.
5. ON PANEL 24VU, ON PROP1 PUSHBUTTON
SWITCH (1):
- FAULT LEGEND OFF,
- ON LEGEND ON.
ON MFD, IN TEMPORARY SELECTION WINDOW,
CYAN 1 PROP 2 MESSAGE IS DISPLAYED.
*** CONTINUED ***
AH

30-61-00
OPT 10010-004
2-400 PAGE
8
DEC 01/14

30-61-00

OPERATIONAL TEST OF
PROPELLERS ANTI-ICING
SYSTEM

OPT 10010-004
9

DEC14

6. WARNINGS DISAPPEAR.
NOTE: TAKE UP THIS TEST WITH CIRCUIT BREAKER
ON PANEL 126VU OPENED:
2DH
PROP2/ANTI-ICING/PWR SPLY AND ON
PANEL 24VU WITH PROP2 PUSHBUTTON
SWITCH (2) PRESSED AND ON MFD WITH
PROP 2 MESSAGE.
7. ON PANEL 24VU,
A. RELEASE PROP MODE SEL PUSHBUTTON
SWITCH (3):
- ON LEGEND OFF,
B. RELEASE MODE SEL/AUTO PUSHBUTTON
SWITCH (5):
- FAULT LEGENDS OFF,
- MAN LEGEND OFF.
C. RELEASE PROP1 AND PROP2 PUSHBUTTON
SWITCHES (1) AND (2) :
- FAULT LEGENDS OFF,
- ON LEGENDS OFF.
ON MFD, IN TEMPORARY SELECTION WINDOW,
1 PROP 2 MESSAGE DISAPPEARS.
NOTE: BY MEANS OF THE PROCEDURE BELOW MAKE
SURE THAT THE FOLLOWING FAILURES ARE
MEMORIZED IN MISCELANEOUS 2 MFC
MAINTENANCE MEMORY:
- ANTI-ICE: LEFT PROPELLER HEATER FAULT
- ANTI-ICE: RIGHT PROPELLER HEATER FAULT
017

______________________________________
SHUT
DOWN OF ENGINE GROUND IDLE RUN-UP
SEE JOB INSTRUCTION CARD
720000-ERU-10030

*** CONTINUED ***


AH

30-61-00
OPT 10010-004
2-400 PAGE
9
DEC 01/14

30-61-00

OPERATIONAL TEST OF
PROPELLERS ANTI-ICING
SYSTEM

018

OPT 10010-004
10

DEC14

_________________________________
READING
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RDG-10000

019

_________________________________
ERASURE
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RON-10000
*****

AH

E N D

O F

T E X T

*****

30-61-00
OPT 10010-004
2-400 PAGE
10
DEC 01/14

30-61-00
11

AH

CONTROLS AND INDICATING


OF PROPELLER ANTI ICING

OPT 10010-004
DEC14

30-61-00
OPT 10010-004

2-400

PAGE
11
DEC 01/14

30-61-00
12

AH

OPERATIONAL TEST OF
PROPELLER ANTI-ICING
SYSTEM

OPT 10010-004
DEC14

30-61-00
OPT 10010-004

2-400

PAGE
12
DEC 01/14

30-61-61

CHECK, INSPECTION AND


CLEANING OF BRUSH BLOCK
AND PROP HEATER ELEMENTS

CHK 10000-001
1

MAR11

ZONING DATA
___________
ZONE
ACCESS

: 210
435
445
: 435AT 445AT

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

GSE

: 01 ACCESS PLATFORM
01 OHMMETER

SPARE

: 06 PROPELLER BRUSHES

BULK MATERIAL : CLEANING AGENTS


CLEANING AGENTS
CLEANING AGENTS

_________
MAN-HOURS

306161-01
11-002
11-012
11-013

PUBLICATION
___________
JIC
JIC

: REMOVAL/INSTALLATION OF
COWLS ATTACHED BY BOLTS
: OPERATIONAL TEST OF
PROP ANTI-ICING SYST
WITH MFC.

AH

54-00-00-RAI-10000
30-61-00-OPT-10010

30-61-61
CHK 10000-001
2-400 PAGE
1
MAR 01/11

30-61-61

CHECK, INSPECTION AND


CLEANING OF BRUSH BLOCK
AND PROP HEATER ELEMENTS

001

CHK 10000-001
2

MAR11

___________
PREPARATION
1. INSTALL ACCESS PLATFORM TO ACCESS TO BRUSH
BLOCK 5011KH LOCATED ON ENGINE.
2. ON PANEL 126VU, SAFETY AND TAG THE FOLLOWING
CIRCUIT BREAKERS :
2DH
25DH

PROP 2/ANTI ICING/PWR SPLY


PROP 1/ANTI ICING/PWR SPLY

3. REMOVE ENGINE COWL 435AT (445AT).


002

REMOVAL OF UPPER FORWARD COWL ATTACHED BY


_________________________________________
BOLTS
_____
SEE JOB INSTRUCTION CARD
540000-RAI-10000

003

______________________
REMOVAL
OF BRUSH BLOCK
SEE:
QUICK ENGINE CHANGE MANUAL (QEC) 71-00-44
ALSO HSD MANUAL 61-26-00

004

________________________________________
CLEANING
OF BRUSH BLOCK HOUSING ASSEMBLY
CAUTION : DO NOT IMMERSE BRUSH BLOCK HOUSING IN
SOLVENT.
DAMAGE TO BRUSHES MAY RESULT.
ONLY USE :
- A CLEAN DRY CLOTH
- DRY FILTERED COMPRESSED AIR.
CAUTION : TO PREVENT CREATING AIRBORNE PARTICLES THAT MAY ENTER EYES, PRESSURE
MUST NOT EXCEED 2 BARS/30 PSI.
EYE PROTECTION REQUIRED.
1. CLEAR BRUSH BLOCK HOUSING FROM :
- CARBON DEPOSITS,
*** CONTINUED ***
AH

30-61-61
CHK 10000-001
2-400 PAGE
2
MAR 01/11

30-61-61

CHECK, INSPECTION AND


CLEANING OF BRUSH BLOCK
AND PROP HEATER ELEMENTS

CHK 10000-001
3

MAR11

- FOREIGN MATERIAL,
- ACCUMULATION OF OIL.
005

REMOVAL OF PROPELLER ANTI-ICING SYSTEM


______________________________________
BRUSHES
_______
REF. FIG. 306161-RAI-00110
1. REMOVE LOCKWIRE, SCREWS (1), WASHERS (2) AND
COVER (3).
2. REMOVE NUTS (4) AND WASHERS (5) AND (8).
3. REMOVE LEADS (6) FROM STUDS AND BRUSHES (7)
THROUGH THE HOLE IN THE FRONT OF THE BLOCK.

006

___________________________________________
CLEANING
OF BRUSH BLOCK HOUSING AND BRUSHES
CAUTION : SOLVENT (11-002 OR 11-012 OR 11-013)
ARE TOXIC AND INFLAMMABLE. AVOID CONTACT WITH SKIN AND EYES, DO NOT BREATHE VAPORS. ONLY USE WITH SUITABLE
VENTILATION.
KEEP AWAY FROM FLAMES OR OTHER HEAT
OR IGNITION SOURCES.
- SOLVENT WILL BE KEPT CLEAN BY THE
USE OF SUITABLE FILTERS.
SOLVENT WILL BE RENEWED PERIODICALY
1. CLEAN BRUSH BLOCK HOUSING WITH SOLVENT
(11-002 OR 11-012 OR 11-013).
IF GRIT OR GREASE DEPOSITS DO NOT FLUSH OFF
READILY, USE :
- A SOFT CLEAN CLOTH,
- A SOFT BRISTLE BRUSH.
2. INTERNAL PASSAGES OF BRUSH BLOCK WILL BE
BLOWN OUT WITH FILTERED COMPRESSED AIR.
3. CLEAN ELECTRICAL CONTACT BRUSHES WITH A
*** CONTINUED ***
AH

30-61-61
CHK 10000-001
2-400 PAGE
3
MAR 01/11

30-61-61

CHECK, INSPECTION AND


CLEANING OF BRUSH BLOCK
AND PROP HEATER ELEMENTS

CHK 10000-001
4

MAR11

CLOTH DAMPENED WITH SOLVENT (11-002 OR


11-012 OR 11-013).
4. CLEAN BRUSHES WITH :
- A CLEAN AND DRY CLOTH,
- FILTERED AND DRY COMPRESSED AIR.
007

INSTALLATION OF PROPELLER ANTI-ICING SYSTEM


___________________________________________
BRUSHES
_______
REF. FIG. 306161-RAI-00110
1. INSTALL THE BRUSHES IN THEIR HOLES AS FOLLOW
A. WITH THE LEAD (6) FIRST, PUSH THE BRUSH
(7) THROUGHT THE HOLE IN THE FRONT OF THE
BLOCK.
B. INSTALL A PLAIN WASHER (5).
C. PUT THE LEAD (6) OF THE FIRST BRUSH ON
ITS TERMINAL STUD (CRIMP UPWARD).
D. PUT THE LEAD (6) OF THE SECOND BRUSH ON
ITS TERMINAL STUD (CRIMP UPWARD).
E. INSTALL A PLAIN WASHER (5).
F. INSTALL A SPRING WASHER (8).
G. INSTALL NUT (4) TO HOLD THE LEADS (6)
(TIGHTENING TORQUE 10 TO 12 LBF..IN./1.13
TO 1.35 M.N.)
H. PUT THE LEAD (9) OF THE CONNECTOR ON ITS
TERMINAL STUD.
I. INSTALL A SPRING WASHER (8).
J. INSTALL NUT (4) TO HOLD THE LEAD (9)
(TIGHTENING TORQUE 10 TO 12 LBF..IN./1.13
*** CONTINUED ***
AH

30-61-61
CHK 10000-001
2-400 PAGE
4
MAR 01/11

30-61-61

CHECK, INSPECTION AND


CLEANING OF BRUSH BLOCK
AND PROP HEATER ELEMENTS

CHK 10000-001
5

MAR11

TO 1.35 M.N.)
2. USE AN OHMMETER TO MAKE A CONTINUITY CHECK
FROM EACH CONNECTOR TO ITS RELATED BRUSHES.
3. INSTALL THE COVER (3) AS FOLLOW :
A. INSTALL COVER (3), WASHER (2) AND SCREW
(1)
B. SAFETY THE SCREW (1) IN PAIRS WITH
LOCKWIRE.
008

___________________________
INSTALLATION
OF BRUSH BLOCK
SEE:
QUICK ENGINE CHANGE MANUAL (QEC) 71-00-44
ALSO HSD MANUAL 61-26-00

009

________
CLOSE-UP
1. MAKE CERTAIN THAT WORKING AREA IS CLEAN
AND CLEAR OF TOOLS AND MISCELLANEOUS
ITEMS OF EQUIPMENT.
2. ENGAGE CIRCUIT BREAKERS PRIVIOUSLY CITE.
3. REMOVE PLATFORM AFTER CLOSING ENGINE COWLS
435AT (445AT) AS FOLLOWS :

010

INSTALLATION OF UPPER FORWARD COWL ATTACHED BY


______________________________________________
BOLTS
_____
SEE JOB INSTRUCTION CARD
540000-RAI-10000

011

OPERATIONAL TEST OF PROP ANTI-ICING SYST


________________________________________
IN NORMAL AND FAST MODE WITH MFC.
_________________________________
SEE JOB INSTRUCTION CARD
306100-OPT-10010
*****
AH

E N D

O F

T E X T

*****

30-61-61
CHK 10000-001
2-400 PAGE
5
MAR 01/11

30-61-61
6

AH

REMOVAL AND INSTALLATION


OF BRUSH BLOCK

CHK 10000-001
MAR11

30-61-61
CHK 10000-001

2-400

PAGE
6
MAR 01/11

30-61-61
7

AH

VISUAL CHECK OF
BRUSH CONDITION

CHK 10000-001
MAR11

30-61-61
CHK 10000-001

2-400

PAGE
7
MAR 01/11

30-61-61
8

AH

REMOVAL/INSTALLATION
OF BRUSHES

CHK 10000-001
MAR11

30-61-61
CHK 10000-001

2-400

PAGE
8
MAR 01/11

30-61-61

DETAILED VISUAL INSPECTION AND CLEANING OF


PROP ANTI-ICING SYSTEM

DVI 10000-001
1

MAR11

ZONING DATA
___________
ZONE
ACCESS

: 210
435
445
: 435AT 445AT

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

GSE

: 01 ACCESS PLATFORM
01 OHMMETER

SPARE

: 06 PROPELLER BRUSHES

BULK MATERIAL : CLEANING AGENTS


CLEANING AGENTS
CLEANING AGENTS

_________
MAN-HOURS

306161-01
11-002
11-012
11-013

PUBLICATION
___________
JIC
JIC

: REMOVAL/INSTALLATION OF
COWLS ATTACHED BY BOLTS
: OPERATIONAL TEST OF
PROP ANTI-ICING SYST
WITH MFC.

AH

54-00-00-RAI-10000
30-61-00-OPT-10010

30-61-61
DVI 10000-001
2-400 PAGE
1
MAR 01/11

30-61-61

DETAILED VISUAL INSPECTION AND CLEANING OF


PROP ANTI-ICING SYSTEM

001

DVI 10000-001
2

MAR11

__________________________________
VISUAL
INSPECTION OF BLADE HEATERS
1. INSPECT EXTERNAL BLADE HEATER FOR BURN HOLES
CAUTION : BLADES WITH BURN HOLES MUST BE
USED WITHIN THE FOLLOWING LIMITATIONS :
- MAXIMUM OPERATION TIME OF 10 HOURS,
- NO OPERATION IN ICING CONDITIONS,
- BURN HOLES MUST BE INSPECTED BEFORE EACH
FLIGHT,
- CRACKS OR FIBERGLASS DEBONDING IS NOT
ALLOWED,
- BURN HOLES MUST BE WITHIN 76 MM./3 IN.
OF BLADE LEADING EDGE, MUST NOT EXCEED
76 MM./3 IN. IN DIAMETER AND MUST NOT
EXTEND THROUGH BLADE.

002

___________
PREPARATION
1. INSTALL ACCESS PLATFORM TO ACCESS TO BRUSH
BLOCK 5011KH LOCATED ON ENGINE.
2. ON PANEL 126VU, SAFETY AND TAG THE FOLLOWING
CIRCUIT BREAKERS :
2DH
25DH

PROP 2/ANTI ICING/PWR SPLY


PROP 1/ANTI ICING/PWR SPLY

3. REMOVE ENGINE COWL 435AT (445AT).


003

REMOVAL OF UPPER FORWARD COWL ATTACHED BY


_________________________________________
BOLTS
_____
SEE JOB INSTRUCTION CARD
540000-RAI-10000

*** CONTINUED ***


AH

30-61-61
DVI 10000-001
2-400 PAGE
2
MAR 01/11

30-61-61

DETAILED VISUAL INSPECTION AND CLEANING OF


PROP ANTI-ICING SYSTEM

004

DVI 10000-001
3

MAR11

VISUAL INSPECTION OF BRUSH BLOCK HOUSING


________________________________________
(ON AIRCRAFT)
_____________
1. INSPECT BRUSH BLOCK HOUSING CONDITION AND
CHECK FOR :
- CARBON DEPOSIT,
- FOREIGN MATERIAL,
- ACCUMULATION OF OIL,
- CRACK,
- BURN MARK,
- ELONGATED BRUSH HOLES IN PAD.
2. INSPECT BRUSHES AND CHECK FOR :
- CRACK,
- WEAR,
- RUPTURE.

005

______________________
REMOVAL
OF BRUSH BLOCK
SEE:
QUICK ENGINE CHANGE MANUAL (QEC) 71-00-44
ALSO HSD MANUAL 61-26-00

006

________________________________________
CLEANING
OF BRUSH BLOCK HOUSING ASSEMBLY
CAUTION : DO NOT IMMERSE BRUSH BLOCK HOUSING IN
SOLVENT.
DAMAGE TO BRUSHES MAY RESULT.
ONLY USE :
- A CLEAN DRY CLOTH
- DRY FILTERED COMPRESSED AIR.
CAUTION : TO PREVENT CREATING AIRBORNE PARTICLES THAT MAY ENTER EYES, PRESSURE
MUST NOT EXCEED 2 BARS/30 PSI.
EYE PROTECTION REQUIRED.
1. CLEAR BRUSH BLOCK HOUSING FROM :
- CARBON DEPOSITS,
- FOREIGN MATERIAL,
- ACCUMULATION OF OIL.
*** CONTINUED ***
AH

30-61-61
DVI 10000-001
2-400 PAGE
3
MAR 01/11

30-61-61

DETAILED VISUAL INSPECTION AND CLEANING OF


PROP ANTI-ICING SYSTEM

007

DVI 10000-001
4

MAR11

___________________________________
CHECK
OF BRUSH CONDITION AND LENGTH
REF.FIG.306161-CHK-00100
1. CHECK BRUSH BLOCK HOUSING FOR CRACKS AND
BURN MARKS.
2. ON BRUSHES, CHECK THAT :
A. LENGTH OF PART OF BRUSHES EXTRUDING FROM
BRUSH BLOCK IS NOT SHORTER THAN 11,4 MM/
0.45 IN.
NOTE : IT MAY BE NECESSARY TO LIGHTLY
PULL ON THE BRUSHES TO MAKE SURE
THAT THEY ARE FULLY EXTENDED.
B. DEPTH OF POSSIBLE CRACKS DOES NOT EXCEED
1 MM./0.04 IN.
C. CONTACT SURFACE DOES NOT BE SHORTER THAN
80% OF INITIAL CONTACT SURFACE.
3. BROKEN BRUSHES ARE REPLACED.

008

REMOVAL OF PROPELLER ANTI-ICING SYSTEM


______________________________________
BRUSHES
_______
REF. FIG. 306161-RAI-00110
1. REMOVE LOCKWIRE, SCREWS (1), WASHERS (2) AND
COVER (3).
2. REMOVE NUTS (4) AND WASHERS (5) AND (8).
3. REMOVE LEADS (6) FROM STUDS AND BRUSHES (7)
THROUGH THE HOLE IN THE FRONT OF THE BLOCK.

009

___________________________________________
CLEANING
OF BRUSH BLOCK HOUSING AND BRUSHES
CAUTION : SOLVENT (11-002 OR 11-012 OR 11-013)
ARE TOXIC AND INFLAMMABLE. AVOID CON*** CONTINUED ***
AH

30-61-61
DVI 10000-001
2-400 PAGE
4
MAR 01/11

30-61-61

DETAILED VISUAL INSPECTION AND CLEANING OF


PROP ANTI-ICING SYSTEM

DVI 10000-001
5

MAR11

TACT WITH SKIN AND EYES, DO NOT BREATHE VAPORS. ONLY USE WITH SUITABLE
VENTILATION.
KEEP AWAY FROM FLAMES OR OTHER HEAT
OR IGNITION SOURCES.
- SOLVENT WILL BE KEPT CLEAN BY THE
USE OF SUITABLE FILTERS.
SOLVENT WILL BE RENEWED PERIODICALY
1. CLEAN BRUSH BLOCK HOUSING WITH SOLVENT
(11-002 OR 11-012 OR 11-013).
IF GRIT OR GREASE DEPOSITS DO NOT FLUSH OFF
READILY, USE :
- A SOFT CLEAN CLOTH,
- A SOFT BRISTLE BRUSH.
2. INTERNAL PASSAGES OF BRUSH BLOCK WILL BE
BLOWN OUT WITH FILTERED COMPRESSED AIR.
3. CLEAN ELECTRICAL CONTACT BRUSHES WITH A
CLOTH DAMPENED WITH SOLVENT (11-002 OR
11-012 OR 11-013).
4. CLEAN BRUSHES WITH :
- A CLEAN AND DRY CLOTH,
- FILTERED AND DRY COMPRESSED AIR.
010

_________________________________
CLEANING
OF ANTI ICING SLIP RINGS
SEE:
HAMILTON STANDARD MAINTENANCE MANUAL 61-10-00

011

__________________________________________
VISUAL
INSPECTION OF ANTI ICING SLIP RINGS
1. INSPECT ANTI ICING SLIP RINGS CONDITION AND
CHECK FOR :
- PITTING,
- GROOVING,
- SIGNS OF ELECTRICAL ARCING,
*** CONTINUED ***
AH

30-61-61
DVI 10000-001
2-400 PAGE
5
MAR 01/11

30-61-61

DETAILED VISUAL INSPECTION AND CLEANING OF


PROP ANTI-ICING SYSTEM

DVI 10000-001
6

MAR11

- SIGNS OF DETERIORATION OF THE INSULATION.


012

INSTALLATION OF PROPELLER ANTI-ICING SYSTEM


___________________________________________
BRUSHES
_______
REF. FIG. 306161-RAI-00110
1. INSTALL THE BRUSHES IN THEIR HOLES AS FOLLOW
A. WITH THE LEAD (6) FIRST, PUSH THE BRUSH
(7) THROUGHT THE HOLE IN THE FRONT OF THE
BLOCK.
B. INSTALL A PLAIN WASHER (5).
C. PUT THE LEAD (6) OF THE FIRST BRUSH ON
ITS TERMINAL STUD (CRIMP UPWARD).
D. PUT THE LEAD (6) OF THE SECOND BRUSH ON
ITS TERMINAL STUD (CRIMP UPWARD).
E. INSTALL A PLAIN WASHER (5).
F. INSTALL A SPRING WASHER (8).
G. INSTALL NUT (4) TO HOLD THE LEADS (6)
(TIGHTENING TORQUE 10 TO 12 LBF..IN./1.13
TO 1.35 M.N.)
H. PUT THE LEAD (9) OF THE CONNECTOR ON ITS
TERMINAL STUD.
I. INSTALL A SPRING WASHER (8).
J. INSTALL NUT (4) TO HOLD THE LEAD (9)
(TIGHTENING TORQUE 10 TO 12 LBF..IN./1.13
TO 1.35 M.N.)
2. USE AN OHMMETER TO MAKE A CONTINUITY CHECK
FROM EACH CONNECTOR TO ITS RELATED BRUSHES.
*** CONTINUED ***
AH

30-61-61
DVI 10000-001
2-400 PAGE
6
MAR 01/11

30-61-61

DETAILED VISUAL INSPECTION AND CLEANING OF


PROP ANTI-ICING SYSTEM

DVI 10000-001
7

MAR11

3. INSTALL THE COVER (3) AS FOLLOW :


A. INSTALL COVER (3), WASHER (2) AND SCREW
(1)
B. SAFETY THE SCREW (1) IN PAIRS WITH
LOCKWIRE.
013

___________________________
INSTALLATION
OF BRUSH BLOCK
SEE:
QUICK ENGINE CHANGE MANUAL (QEC) 71-00-44
ALSO HSD MANUAL 61-26-00

014

________
CLOSE-UP
1. MAKE CERTAIN THAT WORKING AREA IS CLEAN
AND CLEAR OF TOOLS AND MISCELLANEOUS
ITEMS OF EQUIPMENT.
2. ENGAGE CIRCUIT BREAKERS PRIVIOUSLY CITE.
3. REMOVE PLATFORM AFTER CLOSING ENGINE COWLS
435AT (445AT) AS FOLLOWS :

015

INSTALLATION OF UPPER FORWARD COWL ATTACHED BY


______________________________________________
BOLTS
_____
SEE JOB INSTRUCTION CARD
540000-RAI-10000

016

OPERATIONAL TEST OF PROP ANTI-ICING SYST


________________________________________
IN NORMAL AND FAST MODE WITH MFC.
_________________________________
SEE JOB INSTRUCTION CARD
306100-OPT-10010
*****

AH

E N D

O F

T E X T

*****

30-61-61
DVI 10000-001
2-400 PAGE
7
MAR 01/11

30-61-61
8

AH

REMOVAL AND INSTALLATION


OF BRUSH BLOCK

DVI 10000-001
MAR11

30-61-61
DVI 10000-001

2-400

PAGE
8
MAR 01/11

30-61-61
9

AH

VISUAL CHECK OF
BRUSH CONDITION

DVI 10000-001
MAR11

30-61-61
DVI 10000-001

2-400

PAGE
9
MAR 01/11

30-61-61
10

AH

REMOVAL/INSTALLATION
OF BRUSHES

DVI 10000-001
MAR11

30-61-61
DVI 10000-001

2-400

PAGE
10
MAR 01/11

30-61-61

REMOVAL/INSTALLATION OF
ANTI-ICING PROPELLER
BRUSH BLOCK

RAI 10000-001
1

MAR11

ZONING DATA
___________
ZONE
ACCESS

: 210
435
445
: 435AT 445AT

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

GSE

: 01 ACCESS PLATFORM

_________
MAN-HOURS

PUBLICATION
___________
JIC
JIC

: REMOVAL/INSTALLATION OF
COWLS ATTACHED BY BOLTS
: OPERATIONAL TEST OF
PROP ANTI-ICING SYST
WITH MFC.

AH

54-00-00-RAI-10000
30-61-00-OPT-10010

30-61-61
RAI 10000-001
2-400 PAGE
1
MAR 01/11

30-61-61

REMOVAL/INSTALLATION OF
ANTI-ICING PROPELLER
BRUSH BLOCK

001

RAI 10000-001
2

MAR11

___________
PREPARATION
1. INSTALL ACCESS PLATFORM TO ACCESS TO BRUSH
BLOCK 5011KH LOCATED ON ENGINE.
2. ON PANEL 126VU, SAFETY AND TAG THE FOLLOWING
CIRCUIT BREAKERS :
2DH
25DH

PROP 2/ANTI ICING/PWR SPLY


PROP 1/ANTI ICING/PWR SPLY

3. REMOVE ENGINE COWL 435AT (445AT).


002

REMOVAL OF UPPER FORWARD COWL ATTACHED BY


_________________________________________
BOLTS
_____
SEE JOB INSTRUCTION CARD
540000-RAI-10000

003

______________________
REMOVAL
OF BRUSH BLOCK
SEE:
QUICK ENGINE CHANGE MANUAL (QEC) 71-00-44
ALSO HSD MANUAL 61-26-00

004

___________________________
INSTALLATION
OF BRUSH BLOCK
SEE:
QUICK ENGINE CHANGE MANUAL (QEC) 71-00-44
ALSO HSD MANUAL 61-26-00

005

________
CLOSE-UP
1. MAKE CERTAIN THAT WORKING AREA IS CLEAN
AND CLEAR OF TOOLS AND MISCELLANEOUS
ITEMS OF EQUIPMENT.
2. ENGAGE CIRCUIT BREAKERS PRIVIOUSLY CITE.
3. REMOVE PLATFORM AFTER CLOSING ENGINE COWLS
435AT (445AT) AS FOLLOWS :
*** CONTINUED ***
AH

30-61-61
RAI 10000-001
2-400 PAGE
2
MAR 01/11

30-61-61

REMOVAL/INSTALLATION OF
ANTI-ICING PROPELLER
BRUSH BLOCK

006

RAI 10000-001
3

MAR11

INSTALLATION OF UPPER FORWARD COWL ATTACHED BY


______________________________________________
BOLTS
_____
SEE JOB INSTRUCTION CARD
540000-RAI-10000

007

OPERATIONAL TEST OF PROP ANTI-ICING SYST


________________________________________
IN NORMAL AND FAST MODE WITH MFC.
_________________________________
SEE JOB INSTRUCTION CARD
306100-OPT-10010
*****

AH

E N D

O F

T E X T

*****

30-61-61
RAI 10000-001
2-400 PAGE
3
MAR 01/11

30-61-61
4

AH

REMOVAL AND INSTALLATION


OF BRUSH BLOCK

RAI 10000-001
MAR11

30-61-61
RAI 10000-001

2-400

PAGE
4
MAR 01/11

30-61-61

REMOVAL/INSTALLATION OF
PROPELLER BRUSHES

RAI 10010-001
1

APR05

ZONING DATA
___________

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

_________
MAN-HOURS

ELAPSED TIME

GSE

: 01 OHMMETER

SPARE

: 06 PROPELLER BRUSHES

306161-01

: REMOVAL AND INSTALLATION


OF PROPELLER BRUSH BLOC
REMOVAL AND INSTALLATION
OF PROPELLER BRUSH BLOCK
: OPERATIONAL TEST OF
PROP ANTI-ICING SYST
WITH MFC.

30-61-61-RAI-10000

PUBLICATION
___________
JIC

JIC

AH

30-61-00-OPT-10010

30-61-61
RAI 10010-001
2-400 PAGE
1
APR 01/05

30-61-61

REMOVAL/INSTALLATION OF
PROPELLER BRUSHES

001

RAI 10010-001
2

APR05

_______________________________
REMOVAL
OF PROPELLER BRUSH BLOC
SEE JOB INSTRUCTION CARD
306161-RAI-10000

002

REMOVAL OF PROPELLER ANTI-ICING SYSTEM


______________________________________
BRUSHES
_______
REF. FIG. 306161-RAI-00110
1. REMOVE LOCKWIRE, SCREWS (1), WASHERS (2) AND
COVER (3).
2. REMOVE NUTS (4) AND WASHERS (5) AND (8).
3. REMOVE LEADS (6) FROM STUDS AND BRUSHES (7)
THROUGH THE HOLE IN THE FRONT OF THE BLOCK.

003

INSTALLATION OF PROPELLER ANTI-ICING SYSTEM


___________________________________________
BRUSHES
_______
REF. FIG. 306161-RAI-00110
1. INSTALL THE BRUSHES IN THEIR HOLES AS FOLLOW
A. WITH THE LEAD (6) FIRST, PUSH THE BRUSH
(7) THROUGHT THE HOLE IN THE FRONT OF THE
BLOCK.
B. INSTALL A PLAIN WASHER (5).
C. PUT THE LEAD (6) OF THE FIRST BRUSH ON
ITS TERMINAL STUD (CRIMP UPWARD).
D. PUT THE LEAD (6) OF THE SECOND BRUSH ON
ITS TERMINAL STUD (CRIMP UPWARD).
E. INSTALL A PLAIN WASHER (5).
F. INSTALL A SPRING WASHER (8).
*** CONTINUED ***
AH

30-61-61
RAI 10010-001
2-400 PAGE
2
APR 01/05

30-61-61

REMOVAL/INSTALLATION OF
PROPELLER BRUSHES

RAI 10010-001
3

APR05

G. INSTALL NUT (4) TO HOLD THE LEADS (6)


(TIGHTENING TORQUE 10 TO 12 LBF..IN./1.13
TO 1.35 M.N.)
H. PUT THE LEAD (9) OF THE CONNECTOR ON ITS
TERMINAL STUD.
I. INSTALL A SPRING WASHER (8).
J. INSTALL NUT (4) TO HOLD THE LEAD (9)
(TIGHTENING TORQUE 10 TO 12 LBF..IN./1.13
TO 1.35 M.N.)
2. USE AN OHMMETER TO MAKE A CONTINUITY CHECK
FROM EACH CONNECTOR TO ITS RELATED BRUSHES.
3. INSTALL THE COVER (3) AS FOLLOW :
A. INSTALL COVER (3), WASHER (2) AND SCREW
(1)
B. SAFETY THE SCREW (1) IN PAIRS WITH
LOCKWIRE.
004

_____________________________________
INSTALLATION
OF PROPELLER BRUSH BLOCK
SEE JOB INSTRUCTION CARD
306161-RAI-10000

005

OPERATIONAL TEST OF PROP ANTI-ICING SYST


________________________________________
IN NORMAL AND FAST MODE WITH MFC.
_________________________________
SEE JOB INSTRUCTION CARD
306100-OPT-10010
*****

AH

E N D

O F

T E X T

*****

30-61-61
RAI 10010-001
2-400 PAGE
3
APR 01/05

30-61-61
4

AH

REMOVAL/INSTALLATION
OF BRUSHES

RAI 10010-001
APR05

30-61-61
RAI 10010-001

2-400

PAGE
4
APR 01/05

30-61-81

REMOVAL/INSTALLATION OF
CURRENT TRANSFORMER

RAI 10000-001
1

APR05

ZONING DATA
___________
ZONE
ACCESS

: 210
: 212TZ

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

SPARE

: 02 CURRENT TRANSFORMER

EXPENDABLE

: 00 CABLE TIES

_________
MAN-HOURS

306180-02-060

PUBLICATION
___________
JIC

: OPERATIONAL TEST OF
PROP ANTI-ICING SYST
WITH MFC.

AH

30-61-00-OPT-10010

30-61-81
RAI 10000-001
2-400 PAGE
1
APR 01/05

30-61-81

REMOVAL/INSTALLATION OF
CURRENT TRANSFORMER

001

RAI 10000-001
2

APR05

___________
PREPARATION
1. ON PANEL 126VU,OPEN,SAFETY AND TAG THE FOLLOWING CIRCUIT BREAKERS:
25DH
2DH

PROP1 ANTI ICING PWR SPLY


PROP2 ANTI ICING PWR SPLY

2. REMOVE EMERGENCY EQUIPMENT LIABLE TO HINDER


REMOVAL OF PANEL 212TZ.
3. REMOVE PANEL 212TZ.
002

______________________________
REMOVAL
OF CURRENT TRANSFORMER
REF. FIG . 306181-RAI-00100
1. IDENTIFY AND DISCONNECT TERMINAL LUGS (1)
AFTER REMOVAL OF NUTS (2) AND WASHERS (3).
2. REMOVE CABLE TIES (4).
3. REMOVE NUT (6), WASHER (7) TERMINAL LUGS (5)
AND (12) ON TERMINAL 1 OF CONTACTOR 16DH
(3DH).
4. SLOWLY PULL CABLE (8) TO CLEAR IT FROM
CURRENT TRANSFORMER (9).
5. REMOVE NUTS (10), WASHERS (11) AND CURRENT
TRANSFORMER (9).

003

___________________________________
INSTALLATION
OF CURRENT TRANSFORMER
REF. FIG. 306181-RAI-00100
1. CLEAN AND INSPECT SURROUNDING AREA WHERE
TRANSFORMER IS SECURED.
2. INSTALL CURRENT TRANSFORMER (9), WASHERS
(11), BOLTS (10), TIGHTEN.
*** CONTINUED ***
AH

30-61-81
RAI 10000-001
2-400 PAGE
2
APR 01/05

30-61-81

REMOVAL/INSTALLATION OF
CURRENT TRANSFORMER

RAI 10000-001
3

APR05

3. ENGAGE CABLE (8) THROUGH CURRENT TRANSFORMER


(9) AND CONNECT TERMINAL LUGS (5) AND (12)
TO TERMINAL 1 OF CONTACTOR 16DH (3DH).
4. INSTALL WASHER (7), NUR (6), TIGHTEN.
5. INSTALL CABLE TIES (4).
6. CONNECT TERMINAL LUGS (1), INSTALL WASHERS
(3), NUTS (2) TIGHTEN.
004

________
CLOSE-UP
1. MAKE CERTAIN THAT WORKING AREA IS CLEAN AND
CLEAR OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
2. INSTALL PANEL 212TZ.
3. INSTALL EMERGENCY EQUIPMENT PREVIOUSLY
REMOVED.
4. CLOSE CIRCUIT BREAKERS MENTIONED ABOVE.

005

OPERATIONAL TEST OF PROP ANTI-ICING SYST


________________________________________
IN NORMAL AND FAST MODE WITH MFC.
_________________________________
SEE JOB INSTRUCTION CARD
306100-OPT-10010
*****

AH

E N D

O F

T E X T

*****

30-61-81
RAI 10000-001
2-400 PAGE
3
APR 01/05

30-61-81
4

AH

REMOVAL AND INSTALLATION


OF CURRENT TRANSFORMER

RAI 10000-001
APR05

30-61-81
RAI 10000-001

2-400

PAGE
4
APR 01/05

30-61-82

REMOVAL/INSTALLATION OF
PROPELLER CONTACTOR

RAI 10000-001
1

APR05

ZONING DATA
___________
ZONE
ACCESS

: 212
: 212TZ

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

_________
MAN-HOURS

ELAPSED TIME

SPARE

: 01 CONTACTOR

306180-02-030

: OPERATIONAL TEST OF
PROP ANTI-ICING SYST
WITH MFC.

30-61-00-OPT-10010

PUBLICATION
___________
JIC

AH

30-61-82
RAI 10000-001
2-400 PAGE
1
APR 01/05

30-61-82

REMOVAL/INSTALLATION OF
PROPELLER CONTACTOR

001

RAI 10000-001
2

APR05

___________
PREPARATION
1. ON PANEL 126VU,OPEN,SAFETY AND TAG THE FOLLOWING CIRCUIT BREAKERS:
25DH
2DH

PROP2 ANTI ICING PWR SPLY


PROP1 ANTI ICING PWR SPLY

2. REMOVE EMERGENCY EQUIPMENT LIABLE TO HINDER


REMOVABLE OF PANEL 212TZ.
3. REMOVE PANEL 212TZ.
002

______________________________
REMOVAL
OF PROPELLER CONTACTOR
REF.FIG. 306182-RAI-00100
1. IDENTIFY AND DISCONNECT TERMINAL LUGS (1)
AND (2) ON CONTACTOR AFTER REMOVAL OF NUTS
(3) WASHERS (4) AND BOLTS (5).
2. REMOVE ATTACHMENT CLAMPS (11), AND CONTACTOR.

003

___________________________________
INSTALLATION
OF PROPELLER CONTACTOR
REF. FIG. 306182-RAI-00100
1. CLEAN AND INSPECT SURROUNDING AREA WHERE
CONTACTORS ARE SECURED.
NOTE : CENTER CONTACTOR ON HIS BRACKET.
NOTE : CONTACTOR IDENTIFICATION PLATE MUST
BE VISIBLE.
2. INSTALL CONTACTOR USING ATTACHMENT CLAMPS
(11).
3. INSTALL ON CONTACTOR :
- TERMINAL LUGS (2), BOLTS (5), TIGHTEN
*** CONTINUED ***
AH

30-61-82
RAI 10000-001
2-400 PAGE
2
APR 01/05

30-61-82

REMOVAL/INSTALLATION OF
PROPELLER CONTACTOR

RAI 10000-001
3

APR05

TORQUE VALUE FROM 0.049 TO 0.068 M.DAN/


4.3 TO 6 LBF.IN),
- TERMINAL LUGS (1), WASHERS (4), NUTS (3),
TIGHTEN (TORQUE VALUE FROM 0.26 TO
0.29 M.DAN/23 TO 25.6 LBF.IN).
NOTE : DRAW A RED COLORED IDENTIFICATION MARK
(I.E. INDELIBLE INK) ON THE BOLTS AND
THE NUTS.
004

OPERATIONAL TEST OF PROP ANTI-ICING SYST


________________________________________
IN NORMAL AND FAST MODE WITH MFC.
_________________________________
SEE JOB INSTRUCTION CARD
306100-OPT-10010

005

________
CLOSE-UP
1. MAKE CERTAIN THAT WORKING AREA IS CLEAN AND
CLEAR OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
2. INSTALL PANEL 212TZ.
3. INSTALL EMERGENCY EQUIPMENT PREVIOUSLY
REMOVED.
4. CLOSE CIRCUIT BREAKERS MENTIONED ABOVE.
*****

AH

E N D

O F

T E X T

*****

30-61-82
RAI 10000-001
2-400 PAGE
3
APR 01/05

30-61-82
4

AH

REMOVAL AND INSTALLATION


OF PROPELLER CONTACTOR

RAI 10000-001
APR05

30-61-82
RAI 10000-001

2-400

PAGE
4
APR 01/05

30-81-00

FUNCTIONAL TEST OF
ICE DETECTOR

FUT 10000-002
1

MAR12

ZONING DATA
___________
ZONE

: 210
514

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

___
MEN

_________
MAN-HOURS

PUBLICATION
___________
JIC
JIC

: DC AND AC EXTERNAL POWER


SUPPLY
: ERASURE OF MFC
MAINTENANCE MEMORY

AH

24-40-00-EAD-10000
45-13-00-RON-10000

30-81-00
FUT 10000-002
2-400 PAGE
1
MAR 01/12

30-81-00

FUNCTIONAL TEST OF
ICE DETECTOR

001

FUT 10000-002
2

MAR12

___________
PREPARATION
1. ON PANEL 126VU, OPEN,SEFETY AND TAG THE FOLLOWING CIRCUIT BREAKERS:
32DM
48DM
50DM
51DM
63DM

HORNS
HORNS
HORNS
HORNS
HORNS

ANTI
ANTI
ANTI
ANTI
ANTI

ICING
ICING
ICING
ICING
ICING

PWR
PWR
PWR
PWR
PWR

SPLY/R ELEV
SPLY/L AIL
SPLY/R AIL
SPLY/RUD
SPLY/L ELEV

2. ON LEADING EDGE OF LEFT WING, CHECK THAT


PROTECTION OF ICE DETECTOR IS OFF.
002

___________________________________________
ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000

003

______________________
CHECK
OF MFC OPERATION
1. ON PANEL 25VU, CHECK THAT THE FOLLOWING
PUSHBUTTON SWITCHES ARE PRESSED
(OFF LEGENDS ARE OFF):
6UA1
6UA2
7UA1
7UA2

004

MFC/1B/FAULT/OFF
MFC/2B/FAULT/OFF
MFC/1A/FAULT/OFF
MFC/2A/FAULT/OFF

_______________________________
FUNCTIONAL
TEST OF ICE DETECTOR
REF. FIG. 308100-FUT-00100
1. ON PANEL 405VU,
A. CHECK THAT ICE DET/FAULT/ICING (2DD)
CAUTION LIGHT (3) :
- FAULT LEGEND OFF,
- ICING LEGEND OFF.
*** CONTINUED ***
AH

30-81-00
FUT 10000-002
2-400 PAGE
2
MAR 01/12

FUNCTIONAL TEST OF
ICE DETECTOR

30-81-00

FUT 10000-002
3

MAR12

B. CHECK THAT ICING AOA (12DW) PUSHBUTTON


SWITCH (4) IS OFF.
2. ON PANEL 24VU,
A. CHECK THAT DE ICING PUSHBUTTON SWITCHES :
. HORNS, AIRFRAME, 1 ENG 2 AND MODE
SEL ARE RELEASED,
. AFR AIR BLEED IS PRESS.
B. PRESS ON ONE OF THE (1) RUD & L ELEV
(35DM) OR (2) AIL & R ELEV (36DM)
PUSHBUTTON SWITCHES :
- FAULT LEGEND OFF,
- ON LEGEND ON.
3. ON PANEL 405VU,
ICING AOA (12DW) PUSHBUTTON SWITCH (4) IS
ON.
4. ON ICE DETECTOR,
NOTE : THE FUNCTIONAL TEST OF THE ICE DETECTOR CAN BE USED THROUGH TWO DIFFERENT
METHODS. EITHER ONE CAN BE USED.
A. COOLING METHOD,
BUILD ICE ON THE ICE DETECTOR BY THE
FOLLOWING METHOD :
- COOL THE PROBE WITH A FREEZE MIST (CO2
OR OTHER COOLOING AGENT)
- APPLY A VERY FINE MIST OF WATER
- ALTERNATE THE ABOVE UNTIL AT LEAST
0,02 INCH (5 MM) LAYER OF ICE HAS
ACCUMULATED.
B. SQUEEZE METHOD,
- FIRMLY SQEEZE THE PROBE BETWEEN FOREFINGER AND THUMB 0,25 INCH (6 MM) AFT
OF TIP, UNTIL THE PROBE START TO HEAT.
WARNING : WHEN PERFORMING THE SQUEEZE
*** CONTINUED ***
AH

30-81-00
FUT 10000-002
2-400 PAGE
3
MAR 01/12

30-81-00

FUNCTIONAL TEST OF
ICE DETECTOR

FUT 10000-002
4

MAR12

TEST, DO NOT SQUEEZE THE PROBE FOR SEVERAL TIMES IN


SUCCESSION. DOING SO CREATE
THE POTENTIAL OF OVERHEATING
THE PROBE, CAUSING DAMAGE TO
THE DETECTION UNIT. EXERCISE
CAUTION TO AVOID SERIOUS
BURNS WHILE PERFORMING THE
TEST PROCEDURE.
5. ON PANEL 405VU,
A. ON ICE DET/FAULT/ICING (2DD) CAUTION
LIGHT (3) :
- FAULT LEGEND OFF,
- ICING LEGEND ON.
- THE FOLLOWING WARNINGS APPEAR :
. THE CAUTION ANNUNCIATORS FLASH,
. THE SINGLE CHIME SOUNDS.
B. AFTER APPROXMATELY
FAULT/ICING (2DD)
. FAULT LEGEND
. ICING LEGEND

1 MINUTE ON ICE DET/


CAUTION LIGHT (3) :
OFF,
OFF.

- THE FOLLOWING WARNINGS DISAPPEAR :


. THE CAUTION ANNUNCIATORS GOES OFF.
6. ON PANEL 24VU,
RELEASE THE (1) RUD & L ELEV (35DM) OR (2)
AIL & R ELEV (36DM) PUSHBUTTON SWITCH :
- FAULT LEGEND OFF,
- ON LEGEND OFF.
7. ON PANEL 405VU,
- PRESS THEN RELEASED PUSHBUTTON SWITCH (4)
ICING AOA LEGEND GOES OFF.
8. ON PANEL CAP,
PRESS THE CLEAR PUSHBUTTON SWITCH.
*** CONTINUED ***
AH

30-81-00
FUT 10000-002
2-400 PAGE
4
MAR 01/12

30-81-00

FUNCTIONAL TEST OF
ICE DETECTOR

005

FUT 10000-002
5

MAR12

_________________________________
ERASURE
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RON-10000

006

________
CLOSE-UP
1. ON PANEL 126VU, CLOSE CIRCUIT BREAKERS
PREVIOUSLY MENTION.

007

______________________________________________
DE-ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000
*****

AH

E N D

O F

T E X T

*****

30-81-00
FUT 10000-002
2-400 PAGE
5
MAR 01/12

30-81-00
6

AH

FUNCTIONAL TEST OF
ICE DETECTION

FUT 10000-002
MAR12

30-81-00
FUT 10000-002

2-400

PAGE
6
MAR 01/12

30-81-00

OPERATIONAL TEST OF
ICE DETECTOR

OPT 10000-001
1

DEC14

ZONING DATA
___________
ZONE

: 210
514

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

___
MEN

_________
MAN-HOURS

PUBLICATION
___________
JIC

: DC AND AC EXTERNAL POWER


SUPPLY

AH

24-40-00-EAD-10000

30-81-00
OPT 10000-001
2-400 PAGE
1
DEC 01/14

30-81-00

OPERATIONAL TEST OF
ICE DETECTOR

001

OPT 10000-001
2

DEC14

___________
PREPARATION
ON LEADING EDGE OF LEFT WINGS, CHECK THAT PROTECTION OF ICE DETECTOR IS OFF.

002

___________________________________________
ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000

003

______________________
CHECK
OF MFC OPERATION
1. ON PANEL 25VU, CHECK THAT THE FOLLOWING
PUSHBUTTON SWITCHES ARE PRESSED
(OFF LEGENDS ARE OFF):
6UA1
6UA2
7UA1
7UA2

004

MFC/1B/FAULT/OFF
MFC/2B/FAULT/OFF
MFC/1A/FAULT/OFF
MFC/2A/FAULT/OFF

________________________________
OPERATIONAL
TEST OF ICE DETECTOR
REF.FIG 308100-OPT-00100
1. ON PANEL 24VU, CHECK THAT PUSHBUTTON SWITCH
AIRFRAME IS RELEASED :
- FAULT LEGEND OFF,
- ON LEGEND OFF.
2. ON PANEL 405VU :
A. CHECK THAT ANNUNCIATOR (1) ICE/DET/
FAULT/ICING :
- FAULT LEGEND OFF,
- ICING LEGEND OFF.
B. PUSH AND HOLD TEST BUTTON (2) ICE/DET/
PTT :
- ON ANNUNCIATOR ICE/DET/FAULT/ICING
:
*** CONTINUED ***
AH

30-81-00
OPT 10000-001
2-400 PAGE
2
DEC 01/14

30-81-00

OPERATIONAL TEST OF
ICE DETECTOR

OPT 10000-001
3

DEC14

. ICING LEGEND ON AND FLASHING,


. FAULT LEGEND OFF.
- FOLLOWINGS WARNINGS APPEAR :
. ANNUNCIATOR CAUTION ON,
. SINGLE CHIME SOUNDS.
C. RELEASE TEST BUTTON (2) ICE/DET/PTT
:
- ON ANNUNCIATOR ICE/DET/FAULT/ICING
:
. ICING LEGEND OFF,
. FAULT LEGEND OFF.
- WARNINGS DESAPPEAR.
NOTE: IF FAULT LIGHT COMES ON, EITHER
DURING THE TEST OR IN NORMAL OPERATION :
- INTERNAL FAILURE OF SENSOR
CIRCUIT OR ASSOCIATED CIRCUITS,
- DISPLAY OF FOLLOWINGS ALARMS :
. ANNUNCIATOR CAUTION IS ON,
. SINGLE CHIME SOUNDS,
. ANNUNCIATOR ANTI-ICING ON CAP
IS ON.
005

______________________________________________
DE-ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000
*****

AH

E N D

O F

T E X T

*****

30-81-00
OPT 10000-001
2-400 PAGE
3
DEC 01/14

30-81-00
4

AH

OPERATIONAL TEST OF
ICE DETECTION

OPT 10000-001
DEC14

30-81-00
OPT 10000-001

2-400

PAGE
4
DEC 01/14

30-81-00

OPERATIONAL TEST OF
ICE DETECTOR

OPT 10000-002
1

DEC14

ZONING DATA
___________
ZONE

: 210
514

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

___
MEN

_________
MAN-HOURS

PUBLICATION
___________
JIC
JIC

: PRINCIPLE OF CDS USE


(DISPLAY UNITS
EXPLORATION)
: DC AND AC EXTERNAL POWER
SUPPLY

AH

31-63-00-PRO-10000
24-40-00-EAD-10000

30-81-00
OPT 10000-002
2-400 PAGE
1
DEC 01/14

30-81-00

OPERATIONAL TEST OF
ICE DETECTOR

001

OPT 10000-002
2

DEC14

___________
PREPARATION
ON LEADING EDGE OF LEFT WINGS, CHECK THAT PROTECTION OF ICE DETECTOR IS OFF.

002

PRINCIPLE OF CDS USE (DISPLAY UNITS


___________________________________
EXPLORATION)
____________
(TO USE ONLY IF NEEDED)
_______________________
SEE JOB INSTRUCTION CARD
316300-PRO-10000
NOTE: PROCEDURE TO USE ONLY IF NEEDED.
THIS PROCEDURE DESCRIBES LOCATION AND
MANAGEMENT OF THE DIFFERENT DISPLAY
WINDOWS PROVIDED BY THE THREE FORMATS
(PFD, EWD, MFD) PROPOSED ON THE FIVE
DISPLAY UNITS (DU).

003

___________________________________________
ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000

004

______________________
CHECK
OF MFC OPERATION
1. ON PANEL 25VU, CHECK THAT THE FOLLOWING
PUSHBUTTON SWITCHES ARE PRESSED
(OFF LEGENDS ARE OFF):
6UA1
6UA2
7UA1
7UA2

005

MFC/1B/FAULT/OFF
MFC/2B/FAULT/OFF
MFC/1A/FAULT/OFF
MFC/2A/FAULT/OFF

________________________________
OPERATIONAL
TEST OF ICE DETECTOR
REF.FIG 308100-OPT-00100
1.- ON PANEL 24VU, CHECK THAT PUSHBUTTON SWITCH
AIRFRAME IS RELEASED :
*** CONTINUED ***
AH

30-81-00
OPT 10000-002
2-400 PAGE
2
DEC 01/14

OPERATIONAL TEST OF
ICE DETECTOR

30-81-00

OPT 10000-002
3

DEC14

- FAULT LEGEND OFF,


- ON LEGEND OFF.
- ON MFD, IN TEMPORARY SELECTION WINDOW,
CHECK THAT NO AIRFRAME MESSAGE IS
DISPLAYED.
2. ON PANEL 401VU :
A.- ON PFD, IN FMA WINDOW, NO ICING
MESSAGE IS DISPLAYED.
- ON EWD, IN ALERT WINDOW, ICING MESSAGE
IS NOT DISPLAYED.
B. PUSH AND HOLD ICE/DET/PTT PUSHBUTTON:
- ON PFD, IN FMA WINDOW, ICING MESSAGE
FLASHING.
- ON EWD, IN ALERT WINDOW, ICING
MESSAGE APPEARS.
- ON 133VU AND 134VU, MASTER CAUTION
LIGHTS FLASH.
- SINGLE CHIME SOUNDS.
C. RELEASE ICE/DET/PTT PUSHBUTTON:
- ON PFD, IN FMA WINDOW, ICING MESSAGE
DISAPPEARS.
- ON EWD, IN ALERT WINDOW, ICING
MESSAGE DISAPPEARS.
- MASTER CAUTION LIGHTS GO OFF.
NOTE: IF FAULT IS DETECTED, EITHER
DURING THE TEST OR IN NORMAL OPERATION :
- INTERNAL FAILURE OF SENSOR
CIRCUIT OR ASSOCIATED CIRCUITS,
- DISPLAY OF FOLLOWINGS ALARMS :
. MASTER CAUTION LIGHTS ARE ON,
. SINGLE CHIME SOUNDS,
. ON EWD, IN ALERT WINDOW, A-ICING
DETECT MESSAGE APPEARS.

*** CONTINUED ***


AH

30-81-00
OPT 10000-002
2-400 PAGE
3
DEC 01/14

30-81-00

OPERATIONAL TEST OF
ICE DETECTOR

006

OPT 10000-002
4

DEC14

______________________________________________
DE-ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000
*****

AH

E N D

O F

T E X T

*****

30-81-00
OPT 10000-002
2-400 PAGE
4
DEC 01/14

30-81-00
5

AH

OPERATIONAL TEST OF
ICE DETECTION

OPT 10000-002
DEC14

30-81-00
OPT 10000-002

2-400

PAGE
5
DEC 01/14

30-81-71

REMOVAL AND INSTALLATION


OF ICE DETECTOR

RAI 10000-001
1

MAR14

ZONING DATA
___________
ZONE

: 514

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELECTRONIC
ELAPSED TIME

GSE

: 01 ACCESS PLATFORM

SPARE

: 01 ICE DETECTOR

BULK MATERIAL : SEALING PRODUCT


SEALING PRODUCT

_________
MAN-HOURS
01

308170-01-020
09-016
09-018

PUBLICATION
___________
JIC

: OPERATINAL TEST OF
ICE DETECTOR

AH

30-81-00-OPT-10000

30-81-71
RAI 10000-001
2-400 PAGE
1
MAR 01/14

30-81-71

REMOVAL AND INSTALLATION


OF ICE DETECTOR

001

RAI 10000-001
2

MAR14

___________
PREPARATION
1. ON PANEL 122VU, OPEN, SAFETY AND TAG THE
FOLLOWING CIRCUIT BREAKERS :
1DM ANTI/DE ICING/AAS/BOOTS A & B IND
1DD ANTI/DE ICING/ICE DET
2. INSTALL ACCESS PLATFORM TO GAIN ACCESS TO
ICE DETECTOR IN ZONE 514.

002

_______________________
REMOVAL
OF ICE DETECTOR
REF.FIG 308171-RAI-00100
1. REMOVE ATTACHING SCREWS (1) HOLDING THE
SENSOR (2).
2. DISENGAGE SENSOR FROM ITS FLANGE (3).
3. DISCONNECT ELECTRICAL CONNECTOR (4).
4. INSTALL BLANKING PLUGS ON ELECTRICALS CONNECTORS (4) AND (5).

003

____________________________
INSTALLATION
OF ICE DETECTOR
REF.FIG 308171-RAI-00100
1. CHECK FOR CORRECT CONDITION OF ELECTRICAL
CONNECTOR (4) AND VISIBLE SECTION OF WIRING.
CHECK FOR ABSENCE OF CORROSION IN SENSOR
INSTALLATION AREA.
ELIMINATE ALL MASTIC TRACES.
2. COAT THE SURFACE WHESE THE SENSOR MUST BE
INSTALLED WITH SEALING PRODUCT 09-018.
3. REMOVE BLANKING PLUGS.
4. CONNECT ELECTRICAL CONNECTOR (4).
*** CONTINUED ***
AH

30-81-71
RAI 10000-001
2-400 PAGE
2
MAR 01/14

30-81-71

REMOVAL AND INSTALLATION


OF ICE DETECTOR

RAI 10000-001
3

MAR14

5. INSTALL SENSOR (2) IN ITS FLANGE (3).


6. INSTALL AND TIGHTEN SCREWS (1), HOLDING THE
SENSOR (2).
7. COAT GROOVE (6) WITH SEALING COMPOUND 09-016
004

________________________________
OPERATIONAL
TEST OF ICE DETECTOR
SEE JOB INSTRUCTION CARD
308100-OPT-10000

005

________
CLOSE-UP
1. MAKE CERTAIN THAT WORKING AREA IS CLEAN AND
CLEAR OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
2. REMOVE ACCESS PLATFORM.
3. CLOSE CIRCUIT BREAKERS MENTIONED ABOVE.
*****

AH

E N D

O F

T E X T

*****

30-81-71
RAI 10000-001
2-400 PAGE
3
MAR 01/14

30-81-71
4

AH

REMOVAL AND INSTALLATION


OF ICE DETECTOR

RAI 10000-001
MAR14

30-81-71
RAI 10000-001

2-400

PAGE
4
MAR 01/14

30-82-00

OPERATIONAL TEST OF ANTI


ICE
ADVISORY SYSTEM

OPT 10000-002
1

DEC14

ZONING DATA
___________
ZONE

: 210

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

___
MEN

_________
MAN-HOURS

PUBLICATION
___________
JIC
JIC

: DC AND AC EXTERNAL POWER


SUPPLY
: ERASURE OF MFC
MAINTENANCE MEMORY

AH

24-40-00-EAD-10000
45-13-00-RON-10000

30-82-00
OPT 10000-002
2-400 PAGE
1
DEC 01/14

30-82-00

OPERATIONAL TEST OF ANTI


ICE
ADVISORY SYSTEM

001

OPT 10000-002
2

DEC14

___________________________________________
ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000

002

______________________
CHECK
OF MFC OPERATION
1. ON PANEL 25VU, CHECK THAT THE FOLLOWING
PUSHBUTTON SWITCHES ARE PRESSED
(OFF LEGENDS ARE OFF):
6UA1
6UA2
7UA1
7UA2

003

MFC/1B/FAULT/OFF
MFC/2B/FAULT/OFF
MFC/1A/FAULT/OFF
MFC/2A/FAULT/OFF

OPERATIONAL TEST OF ANTI ICING ADVISORY


_______________________________________
SYSTEM
______
REF. FIG. 308200-OPT-00120
1. ON PANEL 405VU,
A. CHECK THAT ICE DETECT (2DD) CAUTION
LIGHT (5) :
- FAULT LEGEND OFF,
- ICING LEGEND OFF.
B. CHECK THAT ICE DETECT/ICING AOA (12DW)
PUSHBUTTON SWITCH (4) IS OFF.
2. ON PANEL 24VU, CHECK THAT DE ICING PUSHBUTTON SWITCHES :
. HORNS, AIRFRAME, 1 ENG 2 AND MODE
SEL ARE RELEASED,
. AFR AIR BLEED IS PRESS.
3. ON PANEL 405VU,
PRESS AND HOLD THE ICE DETECT/PTT (4DD)
*** CONTINUED ***
AH

30-82-00
OPT 10000-002
2-400 PAGE
2
DEC 01/14

OPERATIONAL TEST OF ANTI


ICE
ADVISORY SYSTEM

30-82-00

OPT 10000-002
3

DEC14

TEST PUSHBUTTON SWITCH (6) :


- ON ICE DETECT (2DD) CAUTION LIGHT (5) :
. FAULT LEGEND OFF,
. ICING LEGEND FLASHES.
- THE FOLLOWING WARNINGS APPEAR :
. THE CAUTION ANNUNCIATORS FLASH,
. THE SINGLE CHIME SOUNDS.
4. ON PANEL 24VU,
PRESS THEN RELEASE THE (1) RUD & L ELEV
(35DM) OR (2) AIL & R ELEV (36DM)
PUSHBUTTON SWITCH.
- ON LEGEND OFF,
- FAULT LEGEND OFF.
5. ON PANEL 405VU,
A. ICE DETECT/ICING AOA (12DW) PUSHBUTTON
SWITCH (4) IS ON.
B. PRESS AND HOLD THE }ICE DETECT/PTT} 4DD
C. ON ICE DETECT (2DD) CAUTION LIGHT (5) :
- FAULT LEGEND OFF,
- ICING LEGEND ON FLASHING.
D. THE CAUTION WARNING ANNUNCIATORS
REMAINS FLASHING.
6. ON PANEL 24VU,
PRESS ON AIRFRAME (7DM) PUSHBUTTON SWITCH
(3) :
- FAULT LEGEND OFF,
- ON LEGEND ON.
- ON PANEL 405VU, ICING LEGEND OF ICE
DETECT CAUTION LIGHT (5) GOES ON CONTINUOUSLY.
7. THE CAUTION WARNING ANNUNCIATORS GO OFF.
8. ON PANEL 402VU,
*** CONTINUED ***
AH

30-82-00
OPT 10000-002
2-400 PAGE
3
DEC 01/14

30-82-00

OPERATIONAL TEST OF ANTI


ICE
ADVISORY SYSTEM

OPT 10000-002
4

DEC14

THE DE ICING ANNUNCIATOR (12DM) IS ON.


9. RELEASE THE ICE DETECT/PTT (4DD) TEST
PUSHBUTTON SWITCH (6) :
A. ON PANEL 405VU,
- ICE DETECT (2DD) CAUTION LIGHT (5) :
. FAULT LEGEND OFF,
. ICING LEGEND OFF.
- ICE DETECT/ICING AOA (12DW) PUSHBUTTON SWITCH (4) REMAINS ON.
B. ON PANEL 402VU,
5 MINUTES AFTER HAVING RELEASED TEST
PUSHBUTTON SWITCH (6) THE DE ICING
(12DM) ANNUNCIATOR STARTS FLASHING.
10.ON PANEL 24VU,
RELEASE THE AIRFRAME (7DM) PUSHBUTTON
SWITCH (3) :
- FAULT LEGEND OFF,
- ON LEGEND OFF.
11.ON PANEL 402VU,
THE DE ICING ANNUNCIATOR (12DM) GOES OFF.
12.ON PANEL 405VU,
PRESS THEN RELEASEICE DETECT/ICING AOA
(12DW) PUSHBUTTON SWITCH (4).
- ICING AOA LEGEND GOES OFF.
004

_________________________________
ERASURE
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RON-10000

*** CONTINUED ***


AH

30-82-00
OPT 10000-002
2-400 PAGE
4
DEC 01/14

30-82-00

OPERATIONAL TEST OF ANTI


ICE
ADVISORY SYSTEM

005

OPT 10000-002
5

DEC14

______________________________________________
DE-ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000
*****

AH

E N D

O F

T E X T

*****

30-82-00
OPT 10000-002
2-400 PAGE
5
DEC 01/14

30-82-00
6

AH

OPERATIONAL TEST OF
ADVISORY SYSTEM

OPT 10000-002
DEC14

30-82-00
OPT 10000-002

2-400

PAGE
6
DEC 01/14

30-82-00

OPERATIONAL TEST OF ANTI


ICE
ADVISORY SYSTEM

OPT 10000-003
1

DEC14

ZONING DATA
___________
ZONE

: 210

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

___
MEN

_________
MAN-HOURS

PUBLICATION
___________
JIC
JIC
JIC

: DC AND AC EXTERNAL POWER


SUPPLY
: PRINCIPLE OF CDS USE
(DISPLAY UNITS
EXPLORATION)
: ERASURE OF MFC
MAINTENANCE MEMORY

AH

24-40-00-EAD-10000
31-63-00-PRO-10000
45-13-00-RON-10000

30-82-00
OPT 10000-003
2-400 PAGE
1
DEC 01/14

30-82-00

OPERATIONAL TEST OF ANTI


ICE
ADVISORY SYSTEM

001

OPT 10000-003
2

DEC14

___________________________________________
ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000

002

PRINCIPLE OF CDS USE (DISPLAY UNITS


___________________________________
EXPLORATION)
____________
(TO USE ONLY IF NEEDED)
_______________________
SEE JOB INSTRUCTION CARD
316300-PRO-10000
NOTE: PROCEDURE TO USE ONLY IF NEEDED.
THIS PROCEDURE DESCRIBES LOCATION AND
MANAGEMENT OF THE DIFFERENT DISPLAY
WINDOWS PROVIDED BY THE THREE FORMATS
(PFD, EWD, MFD) PROPOSED ON THE FIVE
DISPLAY UNITS (DU).

003

______________________
CHECK
OF MFC OPERATION
1. ON PANEL 25VU, CHECK THAT THE FOLLOWING
PUSHBUTTON SWITCHES ARE PRESSED
(OFF LEGENDS ARE OFF):
6UA1
6UA2
7UA1
7UA2

004

MFC/1B/FAULT/OFF
MFC/2B/FAULT/OFF
MFC/1A/FAULT/OFF
MFC/2A/FAULT/OFF

OPERATIONAL TEST OF ANTI ICING ADVISORY


_______________________________________
SYSTEM
______
REF. FIG. 308200-OPT-00120
1. A. - ON PFD,
ICING
- ON EWD,
DETECT

IN FMA WINDOW, CHECK THAT NO


MESSAGE IS DISPLAYED.
IN ALERT WINDOW, A-ICING
MESSAGE IS NOT DISPLAYED.

B. - ON PANEL 401VU, CHECK THAT ICE


*** CONTINUED ***
AH

30-82-00
OPT 10000-003
2-400 PAGE
2
DEC 01/14

OPERATIONAL TEST OF ANTI


ICE
ADVISORY SYSTEM

30-82-00

OPT 10000-003
3

DEC14

DET/ICING AOA LIGHT (4) IS OFF.


- ON PFD, IN FMA WINDOW, ICING AOA
MESSAGE IS NOT DISPLAYED.
2. ON PANEL 24VU, CHECK THAT DE ICING
PUSHBUTTON SWITCHES :
- HORNS, AIRFRAME, 1 ENG 2 AND MODE
SEL ARE RELEASED,
- AFR AIR BLEED IS PRESS.
- ON MFD, IN TEMPORARY SELECTION WINDOW,
CHECK THAT HORNS, AIRFRAME AND
1 ENG 2 MESSAGES ARE NOT DISPLAYED.
3. ON PANEL 401VU, PRESS AND HOLD THE ICE
DET/PTT PUSHBUTTON SWITCH (5):
- ON PFD, IN FMA WINDOW, ICING MESSAGE
FLASHES.
- ON EWD, IN ALERT WINDOW, ICING MESSAGE
IS DISPLAYED.
- ON PANEL 133VU AND 134VU, MASTER CAUTION
LIGHTS FLASH.
- THE SINGLE CHIME SOUNDS
4. RELEASE THE ICE DET/PTT TEST PUSHBUTTON
SWITCH (5).
5. ON PANEL 24VU, PRESS THEN RELEASE THE (1)
RUD & L ELEV OR (2) AIL & R ELEV
PUSHBUTTON SWITCH.
- ON LEGEND IS OFF,
- FAULT LEGEND IS OFF.
- ON MFD, IN TEMPORARY SELECTION WINDOW,
1 HORNS 2 MESSAGE IS NOT DISPLAYED.
6. ON PANEL 401VU, ICE DET/ICING AOA LIGHT
(4) IS ON.
- ON PFD, IN FMA WINDOW, GREEN ICING AOA
MESSAGE APPEARS.
- ON PANEL 401VU, PRESS AND HOLD THE
ICE DET/PTT PUSHBUTTON.
- ON PFD, IN FMA WINDOW, YELLOW ICING
*** CONTINUED ***
AH

30-82-00
OPT 10000-003
2-400 PAGE
3
DEC 01/14

30-82-00

OPERATIONAL TEST OF ANTI


ICE
ADVISORY SYSTEM

OPT 10000-003
4

DEC14

MESSAGE FLASHES.
- THE MASTER CAUTION WARNING ANNUNCIATORS
REMAINS FLASHING.
7. ON PANEL 24VU, PRESS ON AIRFRAME
PUSHBUTTON SWITCH (3):
- FAULT LEGEND IS OFF,
- ON LEGEND IS ON.
- ON MFD, IN TEMPORARY SELECTION WINDOW,
CYAN AIRFRAME MESSAGE APPEARS.
- ON PFD, IN FMA WINDOW, YELLOW ICING
MESSAGE IS DISPLAYED WITHOUT FLASHING.
8. THE MASTER CAUTION WARNING ANNUNCIATORS
GO OFF.
9. RELEASE THE ICE DET/PTT PUSHBUTTON
SWITCH (6) :
A. - ON PFD, IN FMA WINDOW, ICING MESSAGE
DISAPPEARS.
- ON PANEL 401, ICE DET/ICING AOA
PUSHBUTTON SWITCH (4) REMAINS ON.
- ON PFD, IN FMA WINDOW, GREEN ICING
AOA MESSAGE REMAINS DISPLAYED.
B. 5 MINUTES AFTER HAVING RELEASED TEST
PUSHBUTTON SWITCH (5) THE AIRFRAME
MESSAGE STARTS FLASHING (ON MFD, IN
TEMPORARY SELECTION WINDOW).
10. ON PANEL 24VU, RELEASE THE AIRFRAME
PUSHBUTTON SWITCH (3):
- FAULT LEGEND IS OFF,
- ON LEGEND IS OFF.
- ON MFD, IN TEMPORARY SELECTION WINDOW,
AIRFRAME MESSAGE DISAPPEARS.
11. ON PANEL 401VU, PRESS THEN RELEASE
ICE DET/ICING AOA PUSHBUTTON SWITCH (4).
- ICING AOA LEGEND GOES OFF.
*** CONTINUED ***
AH

30-82-00
OPT 10000-003
2-400 PAGE
4
DEC 01/14

30-82-00

OPERATIONAL TEST OF ANTI


ICE
ADVISORY SYSTEM

OPT 10000-003
5

DEC14

- ON PFD, IN FMA WINDOW, ICING AOA MESSAGE


DISAPPEARS.
005

_________________________________
ERASURE
OF MFC MAINTENANCE MEMORY
SEE JOB INSTRUCTION CARD
451300-RON-10000

006

______________________________________________
DE-ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000
*****

AH

E N D

O F

T E X T

*****

30-82-00
OPT 10000-003
2-400 PAGE
5
DEC 01/14

30-82-00
6

AH

OPERATIONAL TEST OF
ADVISORY SYSTEM

OPT 10000-003
DEC14

30-82-00
OPT 10000-003

2-400

PAGE
6
DEC 01/14

30-83-00

DETAILED VISUAL
INSPECTION OF LIGHTED
ICING INDICATOR

DVI 10000-001
1

DEC14

ZONING DATA
___________

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

AH

___
MEN

_________
MAN-HOURS

30-83-00
DVI 10000-001
2-400 PAGE
1
DEC 01/14

30-83-00

DETAILED VISUAL
INSPECTION OF LIGHTED
ICING INDICATOR

001

DVI 10000-001
2

DEC14

___________
PREPARATION
POSITION A PLATFORM TO GAIN ACCESS TO LIGHTED
ICING INDICATOR LOCATED AT THE BASE OF THE LH
LATERAL WINDSHIELD.

002

____________________________________________
VISUAL
INSPECTION OF LIGHTED ICING INDICATOR
1. CLEAN AND INSPECT THE AREA AND THE EQUIPMENT
2. CHECK THE ATTACHMENT AND CHECK FOR CRACKS
AND DAMAGE ON THE EQUIPMENT.
3. INSPECT ICE VISUAL INDICATOR FOR PAINT
DAMAGE (PEELING, SCRACHES ETC...)
NOTE: IF PAINT DEFECT IS VISIBLE FROM
COCKPIT, REPLACE ICE VISUAL INDICATOR
PER JIC: 308311-RAI-10000
4. MAKE SURE THAT THE LAMP CHECK POINT IS IN
GOOD CONDITION.
5. CHECK THAT THE LIGHT DIFFUSER IS IN PERFECT
CONDITION (TRANSPARENCY AND ABSENCE OF
CRACKS).

003

________
CLOSE
UP
1. MAKE CERTAIN THAT WORKING AREA IS CLEAN AND
CLEAR OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
2. REMOVE PLATFORM.
*****

AH

E N D

O F

T E X T

*****

30-83-00
DVI 10000-001
2-400 PAGE
2
DEC 01/14

30-83-00
3

AH

LIGHTED ICING INDICATOR

DVI 10000-001
DEC14

30-83-00
DVI 10000-001

2-400

PAGE
3
DEC 01/14

30-83-11

REMOVAL/INSTALLATION OF
ICE VISUAL INDICATOR

RAI 10000-001
1

DEC14

ZONING DATA
___________
ZONE
ACCESS

: 210
: 211DW

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

ELAPSED TIME

GSE

: 01 ACCESS PLATFORM

EXPENDABLE

: 02 SCREW
02 NUT

BULK MATERIAL : SEALANT MATERIAL


CLEANING MATERIAL

_________
MAN-HOURS

308110-01-030
308110-01-010
09-013
11-003

PUBLICATION
___________
JIC
JIC

: NAVIGATION LIGHT
OPERATIONAL TEST
: FUSELAGE PRESSURIZATION
LEAK TEST

AH

33-41-00-OPT-10000
05-53-00-TST-10000

30-83-11
RAI 10000-001
2-400 PAGE
1
DEC 01/14

30-83-11

REMOVAL/INSTALLATION OF
ICE VISUAL INDICATOR

001

RAI 10000-001
2

DEC14

___________
PREPARATION
1. ON PANEL 122VU, OPEN, SAFETY AND TAG THE
FOLLOWING CIRCUIT BREAKER :
4LE COMPT LT & SERVICING/FLT COMPT/CAPT &
F/O EMER LT
2. REMOVE LINING PANEL 211DW.
3. INSTALL ACCESS PLATFORM AT ICE VISUAL
INDICATOR 5DD.

002

_______________________________
REMOVAL
OF ICE VISUAL INDICATOR
REF. FIG. 308311-RAI-00100
NOTE : TWO MEN ARE REQUIRED TO REMOVE THE ICE
VISUAL INDICATOR, ONE INSIDE THE FLIGHT
COMPARTMENT AND ONE OUTSIDE THE AIRCRAFT
1. DISCONNECT THE BUNDLE (1) FROM THE EXTENSION
(2) 447VC.
2. REMOVE THE BUNDLE (1) FROM THE GROOMET (3).
CAUTION : THE WINDOW PANEL CAN BE DAMAGED VERY
EASLY AND THUS DISCARDED.
WATCHES, RINGS, BELTS AND BUCKLES
OR ANY OTHER METAL OBJECTS SHOULD NOT
BE WORN IN AREAS WHERE THEY COULD BE
IN CONTACT WITH THE WINDOW PANEL
OR PLASTIC SURFACES.
3. REMOVE ALL SEALING COMPOUND AROUND THE ICE
VISUAL INDICATOR (7) WITH THE APPROPRIATE
TOOL.
4. REMOVE THE SCREWS (4) (OPERATOR OUTSIDE THE
AIRCRAFT) AND RETAIN THE WASHERS (5) AND NUT
(6) (OPERATOR INSIDE THE AIRCRAFT).
*** CONTINUED ***
AH

30-83-11
RAI 10000-001
2-400 PAGE
2
DEC 01/14

30-83-11

REMOVAL/INSTALLATION OF
ICE VISUAL INDICATOR

RAI 10000-001
3

DEC14

5. REMOVE THE ICE VISUAL INDICATOR (7) AND ITS


BUNDLE (1).
6. USING THE APPROPRIATE TOOL, REMOVE ALL
SEALING COMPOUND IN THE BUNDLE PASSAGE HOLE
AND ON THE BUNDLE.
CAUTION : MATERIAL 11-003 IS FLAMMABLE AND
TOXIC FOR SKIN, EYES AND RESPIRATORY
TRACK. SKIN AND EYES MUST BE
PROTECTED. USE MATERIAL ONLY FOR A
SHORT TIME. USE ONLY IN A WELLVENTILATED AREA.
CAUTION : TAKE CARE TO PROTECT SEALANT AT EDGES
OF WINDOW PANEL. NEVER PERMIT MATERIAL 11-003 TO COME INTO CONTACT WITH
THE WINDOW PANEL. DO NOT DROP SOLVENT
ON OTHER ITEMS OF EQUIPMENT.
7. CLEAN ICE VISUAL INDICATOR EDGES AND FLANGE
AS WELL AS ITS LOCATION WITH MATERIAL 11-003
8. DRY PARTS WITH DRY COMPRESSED AIR.
003

______________________________
VISUAL
INSPECTION OF FASTENERS
CHECK SCREWS (4) AND NUTS (6) FOR DAMAGE AND
REPLACE IF NECESSARY.

004

____________________________________
INSTALLATION
OF ICE VISUAL INDICATOR
REF. FIG. 308311-RAI-00100
1. MAKE SURE THAT THE SURFACES ON WITCH THE
SEALANT MUST BE APPLIED ARE CLEAN.
2. INSERT THE BUNDLE (1) THROUGH THE HOLE UNTIL
THE ICE VISUAL INDICATOR (7) IS IN CONTACT
WITH THE FUSELAGE.
*** CONTINUED ***
AH

30-83-11
RAI 10000-001
2-400 PAGE
3
DEC 01/14

30-83-11

REMOVAL/INSTALLATION OF
ICE VISUAL INDICATOR

RAI 10000-001
4

DEC14

3. INSTALL SCREWS (4), WASHERS (5) AND NUTS (6)


4. TORQUE THE NUTS (6) TO BETWEEN 31 AND 40
LBF.IN (0.35 AND 0.45 M.DAN).
5. APPLY A BEAD OF MATERIAL 09-013 AROUND THE
ICE VISUAL INDICATOR (MAXIMUM DEPTH 1MM).
6. APPLY MATERIAL 09-013 IN THE BUNDLE (1)
PASSAGE HOLE.
7. INSERT THE BUNDLE (1) THROUGH THE GROOMET
(3).
8. CONNECT THE BUNDLE (1) TO THE EXTENSION (2)
447VC.
005

NAVIGATION LIGHTS
_________________
OPERATIONAL TEST
________________
SEE JOB INSTRUCTION CARD
334100-OPT-10000

006

________
CLOSE-UP
1. INTALL LINING PANEL 211DW.
2. REMOVE SAFETY CLIPS AND TAGS AND CLOSE THE
FOLLOWING CIRCUIT BREAKER :
ON PANEL 122VU
4LE

COMPT LT & SERVICING/FLT COMPT/


CAPT & F/O EMER LT

3. REMOVE ACCESS PLATFORM.


NOTE : ALLOW MATERIAL 09-013 TO CURE BEFORE
ACCOMPLISHMENT OF FUSELAGE PRESSURIZATION LEAK TEST.

*** CONTINUED ***


AH

30-83-11
RAI 10000-001
2-400 PAGE
4
DEC 01/14

30-83-11

REMOVAL/INSTALLATION OF
ICE VISUAL INDICATOR

007

RAI 10000-001
5

DEC14

_________________________________
FUSELAGE
PRESSURIZATION LEAK TEST
SEE JOB INSTRUCTION CARD
055300-TST-10000
*****

AH

E N D

O F

T E X T

*****

30-83-11
RAI 10000-001
2-400 PAGE
5
DEC 01/14

30-83-11
6

AH

REMOVAL/INSTALLATION OF
ICE VISUAL INDICATOR

RAI 10000-001
DEC14

30-83-11
RAI 10000-001

2-400

PAGE
6
DEC 01/14

30-83-11

REMOVAL/INSTALLATION OF
ICE EVIDENCE PROBE LAMP

RAI 10010-001
1

DEC14

ZONING DATA
___________

PREPARATION
___________
PROVISION
WORK

: SKILL
_____
ELECTRIC

___
MEN

ELAPSED TIME

GSE

: 01 PLATFORM

SPARE

: 01 308110

_________
MAN-HOURS
01

PUBLICATION
___________
JIC

: NAVIGATION LIGHT
OPERATIONAL TEST

AH

33-41-00-OPT-10000

30-83-11
RAI 10010-001
2-400 PAGE
1
DEC 01/14

30-83-11

REMOVAL/INSTALLATION OF
ICE EVIDENCE PROBE LAMP

001

RAI 10010-001
2

DEC14

___________
PREPARATION
1. ON PANEL 122VU OPEN,SAFETY AND TAG THE
FOLLOWING CIRCUIT BREAKER:
4LE COMPT LT & SERVICING/FLT/COMPT/CAPT &
F/O EMER. LIGHT
2. INSTALL A PLATFORM TO GAIN THE ACCESS TO THE
ICE EVIDENCE PROBE. (IEP)

002

_______
REMOVAL
REF.FIG.:308311-RAI-00110
1. UNSCREW BOTH THE SCREW (1) AND DISCARD THEM.
2. REMOVE THE PLATE (2).
3. REMOVE THE TRANSPARENT COVER (3)
3. PULL OUT THE LAMP HOLDER (4).
4. REMOVE THE BI-PIN LAMP (5).

003

____________
INSTALLATION
REF.FIG.308311-RAI-00110
NOTE: AS PER CMMV INDICATION(30-81-11) INSTALL
NEW SCREW (1) AFTER EVERY UNSCREWING.
1. INSTALL THE BI-PIN LAMP (5).
2. REINSTALL THE LAMP HOLDER (4).
3. REINSTALL THE TRANSPARENT COVER (3)
3. INSTALL THE PLATE (2).
4. INSTALL AND TIGHTEN THE SCREW (1)
*** CONTINUED ***
AH

30-83-11
RAI 10010-001
2-400 PAGE
2
DEC 01/14

30-83-11

REMOVAL/INSTALLATION OF
ICE EVIDENCE PROBE LAMP

004

RAI 10010-001
3

DEC14

________
CLOSE-UP
1. REMOVE THE PLATFORM.
2. CLOSE THE CIRCUIT BREAKER PREVIOUSLY OPENED.

005

NAVIGATION LIGHTS
_________________
OPERATIONAL TEST
________________
SEE JOB INSTRUCTION CARD
334100-OPT-10000
*****

AH

E N D

O F

T E X T

*****

30-83-11
RAI 10010-001
2-400 PAGE
3
DEC 01/14

30-83-11
4

AH

ICE EVIDENCE PROBE

RAI 10010-001
DEC14

30-83-11
RAI 10010-001

2-400

PAGE
4
DEC 01/14

30-84-00

OPERATIONAL TEST OF APM

OPT 10000-001
1

MAR11

ZONING DATA
___________
ZONE

: 210

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

___
MEN

_________
MAN-HOURS

PUBLICATION
___________
JIC

: DC AND AC EXTERNAL POWER


SUPPLY

AH

24-40-00-EAD-10000

30-84-00
OPT 10000-001
2-400 PAGE
1
MAR 01/11

OPERATIONAL TEST OF APM

30-84-00

OPT 10000-001
2

001

MAR11

___________________________________________
ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000

002

_______________________
OPERATIONAL
TEST OF APM
REF. FIG. 308400-OPT-00100
1. PUSH AND MAINTAIN APM TEST PUSH-BUTTON ON
5VU AND VERIFY TEST RESULT:
- CRUISE SPEED LOW INDICATOR LIGHT ON 13VU
(LEFT AND RIGHT SIDE) ILLUMINATED.
- OVER 1 SECOND LATER:
DEGRADED PERF INDICATOR LIGHT ON 13VU
(LEFT AND RIGHT SIDE) ILLUMINATED,
CAUTION LIGHT ILLUMINATED
SINGLE CHIME
CRUISE SPEED LOW LIGHT ALWAYS
ILLUMINATED
- OVER 1 SECOND LATER:
INCREASE SPEED INDICATOR LIGHTS ON 13VU
(LEFT AND RIGHT SIDE) ILLUMINATED FLASHING
CAUTION LIGHT ILLUMINATED
SINGLE CHIME
CRUISE SPEED LOW LIGHT ALWAYS
ILLUMINATED
DEGRADED PERF LIGHT ALWAYS ILLUMINATED
- OVER 1 SECOND LATER:
FAULT LIGHT ON 5VU ILLUMINATED
CAUTION LIGHT ILLUMINATED ON CAP
SINGLE CHIME
ANTI-ICING LIGHT ILLUMINATED ON CAP
CRUISE SPEED LOW LIGHT ALWAYS
ILLUMINATED
DEGRADED PERF LIGHT ALWAYS ILLUMINATED
INCREASE SPEED LIGHT ALWAYS ILLUMINATED
*** CONTINUED ***
AH

30-84-00
OPT 10000-001
2-400 PAGE
2
MAR 01/11

30-84-00

OPERATIONAL TEST OF APM

OPT 10000-001
3

MAR11

FLASHING.
2. RELEASE TEST PUSH-BUTTON AND VERIFY THAT ALL
THE LIGHTS SHALL BE OFF.
003

______________________________________________
DE-ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000
*****

AH

E N D

O F

T E X T

*****

30-84-00
OPT 10000-001
2-400 PAGE
3
MAR 01/11

30-84-00
4

AH

OPERATIONAL TEST OF APM

OPT 10000-001
MAR11

30-84-00
OPT 10000-001

2-400

PAGE
4
MAR 01/11

30-84-00

OPERATIONAL TEST OF APM

OPT 10000-002
1

DEC14

ZONING DATA
___________
ZONE

: 210

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

ELAPSED TIME

___
MEN

_________
MAN-HOURS

PUBLICATION
___________
JIC
JIC

: PRINCIPLE OF CDS USE


(DISPLAY UNITS
EXPLORATION)
: DC AND AC EXTERNAL POWER
SUPPLY

AH

31-63-00-PRO-10000
24-40-00-EAD-10000

30-84-00
OPT 10000-002
2-400 PAGE
1
DEC 01/14

30-84-00

OPERATIONAL TEST OF APM

OPT 10000-002
2

001

DEC14

PRINCIPLE OF CDS USE (DISPLAY UNITS


___________________________________
EXPLORATION)
____________
(TO USE ONLY IF NEEDED)
_______________________
SEE JOB INSTRUCTION CARD
316300-PRO-10000
NOTE: PROCEDURE TO USE ONLY IF NEEDED.
THIS PROCEDURE DESCRIBES LOCATION AND
MANAGEMENT OF THE DIFFERENT DISPLAY
WINDOWS PROVIDED BY THE THREE FORMATS
(PFD, EWD, MFD) PROPOSED ON THE FIVE
DISPLAY UNITS (DU).

002

___________________________________________
ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000

003

_______________________
OPERATIONAL
TEST OF APM
NOTE : AS THE TEST SEQUENCE CONSIST ON A
FAST APPEARING OF SEVERAL DISPLAYS,
TEST IS DESCRIBED MORE VISUAL.
REF. FIG. 308400-OPT-00100
1. ON 401VM:
- PRESS AND HOLD THE APM/TEST PUSHBUTTON
SWITCH.
2. CHECK THAT TEST SEQUENCE DESCRIBED ON THE
FIGURE IS CORRECT.
3. ON 401VM:
- RELEASE THE APM/TEST PUSHBUTTON SWITCH
AND VERIFY THAT ALL ALERTS ARE OFF.

004

______________________________________________
DE-ENERGIZATION
OF AIRCRAFT AC AND DC NETWORKS
SEE JOB INSTRUCTION CARD
244000-EAD-10000
*****
AH

E N D

O F

T E X T

*****

30-84-00
OPT 10000-002
2-400 PAGE
2
DEC 01/14

30-84-00
3

AH

OPERATIONAL TEST OF APM

OPT 10000-002
DEC14

30-84-00
OPT 10000-002

2-400

PAGE
3
DEC 01/14

30-84-00

REMOVAL AND INSTALLATION


OF APIU

RAI 10000-002
1

MAR14

ZONING DATA
___________
ZONE
ACCESS

: 211
: 211FZ

PREPARATION
___________
PROVISION
WORK

: SKILL
_____

___
MEN

_________
MAN-HOURS

ELAPSED TIME

SPARE

: 01 APIU

313110-01

: REMOVAL AND INSTALLATION


OF CAPTAIN AND FIRST
OFFICER SEATS
REMOVAL AND INSTALLATION
OF CAPTAIN (FIRST
OFFICER) SEAT
: OPERATIONAL TEST OF APM

25-11-11-RAI-10000

PUBLICATION
___________
JIC

JIC

AH

30-84-00-OPT-10000

30-84-00
RAI 10000-002
2-400 PAGE
1
MAR 01/14

30-84-00

REMOVAL AND INSTALLATION


OF APIU

001

RAI 10000-002
2

MAR14

_______________________
REMOVAL
OF CAPTAIN SEAT
SEE JOB INSTRUCTION CARD
251111-RAI-10000
REMOVE ONLY CAPTAIN SEAT.

002

___________
PREPARATION
1. OPEN, SAFETY AND TAG THE FOLLOWING
CIRCUIT BREAKERS:
ON PANEL 21VU,
4TU
DFDR/FDAU MPC APIU FLY SPLY
159TU
DFDR/FDAU MPC APIU GND SPLY
214TU
MPC/APM FAULT
2. OPEN ACCESS PANEL 211 FZ

003

_______
REMOVAL
REF. FIG. 308400-RAI-00100
1. DISCONNECT ELECTRICAL CONNECTOR (1) AND
INSTALL PROTECTIVE CAP.
2. INSTALL PROTECTIVE CAP ON THE APIU.
3. REMOVE SCREWS (2) AND WASHERS (3).
4. REMOVE APIU (4).

004

____________
INSTALLATION
REF. FIG. 308400-RAI-00100
1. INSTALL APIU (4).
2. INSTALL WASHERS (3), SCREWS (2) AND TIGHTEN
IT.
3. REMOVE PROTECTIVE CAPS
4. CONNECT ELECTRICAL CONNECTOR (1).

*** CONTINUED ***


AH

30-84-00
RAI 10000-002
2-400 PAGE
2
MAR 01/14

30-84-00

REMOVAL AND INSTALLATION


OF APIU

005

RAI 10000-002
3

MAR14

________
CLOSE-UP
1. MAKE CERTAIN THAT WORKING AERA IS CLEAN AND
CLEAR OF TOOLS AND MISCELLANEOUS ITEMS OF
EQUIPMENT.
2. CLOSE ACCESS PANEL 211FZ.
3. CLOSE CIRCUIT BREAKERS PREVIOUSLY OPENED.

006

____________________________
INSTALLATION
OF CAPTAIN SEAT
SEE JOB INSTRUCTION CARD
251111-RAI-10000

007

_______________________
OPERATIONAL
TEST OF APM
SEE JOB INSTRUCTION CARD
308400-OPT-10000
*****

AH

E N D

O F

T E X T

*****

30-84-00
RAI 10000-002
2-400 PAGE
3
MAR 01/14

30-84-00
4

AH

REMOVAL AND INSTALLATION


OF APIU

RAI 10000-002
MAR14

30-84-00
RAI 10000-002

2-400

PAGE
4
MAR 01/14

12 - MAR 01/15

30-11-00-OPT-10000-003
30-11-00-OPT-10000-004
30-11-00-OPT-10000-005
30-11-00-OPT-10000-006
30-11-00-OPT-10000-007
30-11-00-OPT-10000-008
30-31-83-RAI-10000-001
30-45-11-RAI-10000-001

AH

TASK DELETED
TASK DELETED
TASK DELETED
NEW TASK
NEW TASK
NEW TASK
MINOR INFORMATION ADDITION
MINOR INFORMATION ADDITION

051
061
063
051
061
063
ALL
ALL

TO
TO
TO
TO
TO
TO

060
062
065
060
062
065

12
PAGE
1
MAR 01/15

PAGE

1 TO

10 DEC/14

51 TO

60

1 TO

10 DEC/14

61 TO

62

1 TO

11 DEC/14

63 TO

65

1 TO

9 DEC/14

51 TO

60

1 TO

9 DEC/14

61 TO

62

1 TO

9 DEC/14

63 TO

65

1 TO

4 APR/05

ALL

1 TO

7 APR/05

ALL

1 TO

7 DEC/14

51 TO

60

1 TO

7 DEC/14

61 TO

62

1 TO

7 DEC/14

63 TO

65

TO

DEC/14

51 TO

60

TO

DEC/14

61 TO

62

TO

DEC/14

63 TO

65

1 TO

14 MAR/15

51 TO

60

REVISION NO 12 - MAR/15

30-00-00-OPT-10000-001 OPERATIONAL TEST OF


STANDBY DE-ICING SYSTEM
AND ASSOCIATED ALERTS
30-00-00-OPT-10000-002 OPERATIONAL TEST OF
STANDBY DE-ICING SYSTEM
AND ASSOCIATED ALERTS
30-00-00-OPT-10000-003 OPERATIONAL TEST OF
STANDBY DE-ICING SYSTEM
AND ASSOCIATED ALERTS
30-00-00-OPT-10010-003 OPERATIONAL TEST OF
DE-ICING CYCLES
30-00-00-OPT-10010-004 OPERATIONAL TEST OF
DE-ICING CYCLES
30-00-00-OPT-10010-005 OPERATIONAL TEST OF
DE-ICING CYCLES
30-11-00-CHK-10000-001 CHECK CORRECT OPERATION
OF ANTI ICE HORNS
CONTROLLER
30-11-00-FUT-10000-001 FUNCTIONAL TEST OF
ELECTRICAL HEATERS
VALVES
30-11-00-GVI-10000-001 OPERATIONAL TEST AND
VISUAL CHECK OF DE-ICER
BONDING
30-11-00-GVI-10000-002 OPERATIONAL TEST AND
VISUAL CHECK OF DE-ICER
BONDING
30-11-00-GVI-10000-003 OPERATIONAL TEST AND
VISUAL CHECK OF DE-ICER
BONDING
30-11-00-OPT-10000-003 OPERATIONAL TEST OF
AIRFOIL DE-ICING SYSTEM
30-11-00-OPT-10000-004 OPERATIONAL TEST OF
AIRFOIL DE-ICING SYSTEM
30-11-00-OPT-10000-005 OPERATIONAL TEST OF
AIRFOIL DE-ICING SYSTEM
30-11-00-OPT-10000-006 OPERATIONAL TEST OF
AIRFOIL DE-ICING SYSTEM

D
D
N

AH

1
MAR/15

PAGE

1 TO

14 MAR/15

61 TO

62

1 TO

15 MAR/15

63 TO

65

1 TO

7 DEC/14

51 TO

62

1 TO

8 DEC/14

63 TO

65

1 TO

6 DEC/14

51 TO

60

1 TO

6 DEC/14

61 TO

62

1 TO

6 DEC/14

63 TO

65

1 TO

3 MAR/12

ALL

1 TO

4 APR/05

ALL

1 TO

5 MAR/14

ALL

1 TO

5 MAR/11

51 TO

60

1 TO

5 DEC/14

61 TO

65

1 TO

4 MAR/12

ALL

1 TO

4 APR/05

ALL

1 TO

5 APR/05

ALL

1 TO

9 DEC/14

51 TO

60

1 TO

9 DEC/14

61 TO

62

1 TO

10 DEC/14

63 TO

65

REVISION NO 12 - MAR/15

N 30-11-00-OPT-10000-007 OPERATIONAL TEST OF


AIRFOIL DE-ICING SYSTEM
N 30-11-00-OPT-10000-008 OPERATIONAL TEST OF
AIRFOIL DE-ICING SYSTEM
30-11-00-OPT-10030-001 OPERATIONAL TEST OF
ANTI-ICING AND WARNING
OF EACH HORN
30-11-00-OPT-10030-002 OPERATIONAL TEST OF
ANTI-ICING AND WARNING
OF EACH HORN
30-11-00-OPT-10060-001 OPERATIONAL TEST OF
AIRFRAME DE-ICING
30-11-00-OPT-10060-002 OPERATIONAL TEST OF
AIRFRAME DE-ICING
30-11-00-OPT-10060-003 OPERATIONAL TEST OF
AIRFRAME DE-ICING
30-11-00-REP-10040-001 REPAIR OF PNEUMATIC
DE-ICERS
30-11-00-SRV-10020-001 SERVICING OF PNEUMATIC
DE-ICERS
30-11-31-RAI-10000-001 REMOVAL/INSTALLATION OF
EMPENNAGE DUAL
DISTRIBUTOR VALVE
30-11-33-OPT-10000-001 OPERATIONAL TEST OF
EMPENNAGE WATER DRAIN
OPENING
30-11-33-OPT-10000-002 OPERATIONAL TEST OF
EMPENNAGE WATER DRAIN
OPENING
30-11-33-RAI-10010-001 REMOVAL/INSTALLATION OF
EMPENNAGE PIPES WATER
DRAIN
30-11-43-RAI-10000-001 REMOVAL AND INSTALLATION
OF RUDDER HORN
30-11-44-RAI-10000-001 REMOVAL AND INSTALLATION
OF ELEVATOR HORN
30-11-61-OPT-10000-005 OPERATIONAL TEST OF REGU
LATOR AND SHUT OFF VALVE
BY USING ENG FIRE HANDLE
30-11-61-OPT-10000-006 OPERATIONAL TEST OF REGU
LATOR AND SHUT OFF VALVE
BY USING ENG FIRE HANDLE
30-11-61-OPT-10000-007 OPERATIONAL TEST OF REGU
LATOR AND SHUT OFF VALVE
BY USING ENG FIRE HANDLE
AH

2
MAR/15

PAGE

1 TO

6 DEC/14

51 TO

60

1 TO

8 DEC/14

61 TO

62

1 TO

8 DEC/14

63 TO

65

1 TO

5 MAR/12

51 TO

60

1 TO

5 DEC/14

61 TO

65

1 TO

7 APR/05

ALL

1 TO

4 APR/05

ALL

1 TO

4 MAR/14

ALL

1 TO

4 MAR/12

ALL

1 TO

6 MAR/12

ALL

1 TO

6 MAR/12

ALL

1 TO

4 APR/05

ALL

1 TO

2 APR/05

ALL

1 TO

2 APR/05

ALL

1 TO

2 APR/05

ALL

1 TO

6 MAR/11

51 TO

60

1 TO

6 DEC/14

61 TO

65

1 TO

4 APR/05

ALL

REVISION NO 12 - MAR/15

30-11-61-OPT-10010-004 OPERATIONAL TEST OF


PRESSURE AND REGULATING
SHUT OFF VALVE
30-11-61-OPT-10010-005 OPERATIONAL TEST OF
PRESSURE AND REGULATING
SHUT OFF VALVE
30-11-61-OPT-10010-006 OPERATIONAL TEST OF
PRESSURE AND REGULATING
SHUT OFF VALVE
30-11-61-RAI-10000-001 REMOVAL/INSTALLATION OF
PRESSURE REGULATOR AND
SHUT OFF VALVE
30-11-61-RAI-10000-002 REMOVAL/INSTALLATION OF
PRESSURE REGULATOR AND
SHUT OFF VALVE
30-11-62-RAI-10000-001 REMOVAL/INSTALLATION OF
SHUT OFF VALVES
30-11-65-RAI-10000-001 REMOVAL/INSTALLATION OF
DRAINS WATER
30-11-66-RAI-10000-001 REMOVAL/INSTALLATION OF
OVERHEAT THERMAL SWITCH
30-11-71-RAI-10000-001 REMOVAL AND INSTALLATION
OF AIR BLEED PRESSURE
SWITCH
30-11-72-RAI-10000-001 REMOVAL/INSTALLATION OF
WING CENTER LINE DUAL
DISTRIBUTOR VALVE
30-11-72-RAI-10010-001 REMOVAL/INSTALLATION OF
OUTER WING DUAL
DISTRIBUTOR VALVE
30-11-74-RAI-10000-001 REMOVAL AND INSTALLATION
OF AILERON HORN
30-11-75-RAI-10000-001 REMOVAL/INSTALLATION OF
OUTER WING DE-ICER
30-11-75-RAI-10010-001 REMOVAL/INSTALLATION OF
CENTER WING DE-ICER
30-11-75-RAI-10020-001 REMOVAL/INSTALLATION OF
INNER WING DE-ICER
30-11-76-OPT-10000-001 OPERATIONAL TEST OF
WING PIPES WATER DRAINS
30-11-76-OPT-10000-002 OPERATIONAL TEST OF
WING PIPES WATER DRAINS
30-11-76-RAI-10010-001 REMOVAL/INSTALLATION OF
WING PIPES WATER DRAINS
AH

3
MAR/15

PAGE

1 TO

4 APR/05

ALL

1 TO

4 APR/05

ALL

1 TO

4 APR/05

ALL

1 TO

15 DEC/14

51 TO

60

1 TO

15 DEC/14

61 TO

62

1 TO

16 DEC/14

63 TO

65

1 TO

5 APR/05

ALL

1 TO

4 APR/05

ALL

1 TO

2 APR/05

51 TO

51

1 TO

2 DEC/14

52 TO

65

1 TO

2 APR/05

51 TO

51

1 TO

2 DEC/14

52 TO

65

1 TO

2 APR/05

51 TO

51

1 TO

2 DEC/14

52 TO

65

1 TO

7 MAR/12

ALL

1 TO

9 DEC/14

51 TO

REVISION NO 12 - MAR/15

30-11-82-RAI-10000-001 REMOVAL/INSTALLATION OF
HORN ANTI ICING
CONTROLLERS
30-11-83-RAI-10000-001 REMOVAL/INSTALLATION OF
STANDBY DE-ICING CONTROL
UNIT
30-21-00-DVI-10000-001 DETAILLED VISUAL
INSPECTION OF ENGINES
DE-ICERS HOSES
30-21-00-OPT-10000-003 OPERATIONAL TEST OF
ENGINE AIR INTAKE DEICING SYSTEM
30-21-00-OPT-10000-004 OPERATIONAL TEST OF
ENGINE AIR INTAKE DEICING SYSTEM
30-21-00-OPT-10000-005 OPERATIONAL TEST OF
ENGINE AIR INTAKE DEICING SYSTEM
30-21-61-RAI-10000-001 REMOVAL/INSTALLATION OF
ENGINE DUAL DISTRIBUTOR
VALVES
30-21-64-RAI-10000-001 REMOVAL/INSTALLATION OF
PRESSURE SWITCH
30-21-65-RAI-10000-001 REMOVAL/INSTALLATION OF
ENGINE AIR INTAKE
DE-ICER
30-21-65-RAI-10000-002 REMOVAL/INSTALLATION OF
ENGINE AIR INTAKE
DE-ICER
30-21-65-RAI-10010-001 REMOVAL/INSTALLATION OF
ENGINE AIR INTAKE THROAT
DE-ICER
30-21-65-RAI-10010-002 REMOVAL/INSTALLATION OF
ENGINE AIR INTAKE THROAT
DE-ICER
30-21-65-RAI-10020-001 REMOVAL/INSTALLATION OF
OIL COOLER DE-ICER
30-21-65-RAI-10020-002 REMOVAL/INSTALLATION OF
OIL COOLER DE-ICER
30-31-00-OPT-10000-001 OPERATIONAL TEST OF
HEATING SYSTEM
INDICATING
30-31-00-OPT-10010-001 OPERATIONAL TEST OF
PITOT PROBES HEATING
AH

62

4
MAR/15

PAGE

1 TO

9 DEC/14

63 TO

1 TO

7 MAR/15

ALL

1 TO

3 MAR/14

ALL

1 TO

5 DEC/14

51 TO

62

1 TO

5 DEC/14

63 TO

65

1 TO

5 DEC/14

51 TO

62

1 TO

5 DEC/14

63 TO

65

1 TO

4 APR/05

ALL

1 TO

4 APR/05

ALL

1 TO

5 MAR/14

ALL

1 TO

4 DEC/14

ALL

1 TO

4 MAR/15

ALL

1 TO

4 APR/05

ALL

1 TO
1 TO

5 APR/05
5 APR/05

ALL
ALL

1 TO

11 DEC/14

51 TO

62

1 TO

12 DEC/14

63 TO

65

1 TO

8 MAR/11

ALL

REVISION NO 12 - MAR/15

30-31-00-OPT-10010-002 OPERATIONAL TEST OF


PITOT PROBES HEATING
R 30-31-83-RAI-10000-001 REMOVAL AND INSTALLATION
OF CURRENT SENSORS
30-42-00-OPT-10000-001 OPERATIONAL TEST OF
WINDSHIELD HEATING
30-42-00-OPT-10010-001 OPERATIONAL TEST OF SIDE
WINDOW HEATING
30-42-00-OPT-10010-002 OPERATIONAL TEST OF SIDE
WINDOW HEATING
30-42-00-OPT-10020-001 OPT OF WINDSHIELD TEMPERATURE CONTROLLERS AND
ASSOCIATED CIRCUITS
30-42-00-OPT-10020-003 OPT OF WINDSHIELD TEMPERATURE CONTROLLERS AND
ASSOCIATED CIRCUITS
30-42-00-PRO-10000-001 SWAPPING PROCEDURE OF
THERMAL SENSOR FOR
WINDSHIELD
30-42-00-PRO-10020-001 SWAPPING PROCEDURE OF
THERMAL SENSOR FOR
F/O SIDE WINDOW
30-42-11-RAI-10000-001 REMOVAL AND INSTALLATION
OF WINDSHIELD
TEMPERATURE CONTROLLER
30-45-00-OPT-10000-001 OPERATIONAL TEST OF
WINDSHIELD RAIN REMOVAL
SYSTEM
R 30-45-11-RAI-10000-001 REMOVAL AND INSTALLATION
OF WIPER MOTOR
30-45-12-RAI-10000-001 REMOVAL AND INSTALLATION
OF WIPER ARM
30-45-14-ADJ-10000-001 WIPER BLADE ADJUSTMENT
30-45-14-RAI-10000-001 REMOVAL AND INSTALLATION
OF WIPER BLADE
30-61-00-OPT-10010-003 OPERATIONAL TEST OF
PROPELLERS ANTI-ICING
SYSTEM
30-61-00-OPT-10010-004 OPERATIONAL TEST OF
PROPELLERS ANTI-ICING
SYSTEM
30-61-61-CHK-10000-001 CHECK, INSPECTION AND
CLEANING OF BRUSH BLOCK
AND PROP HEATER ELEMENTS
AH

65

5
MAR/15

PAGE

1 TO

10 MAR/11

ALL

1 TO

4 MAR/11

ALL

1 TO

4 APR/05

ALL

1 TO

4 APR/05

ALL

1 TO

4 APR/05

ALL

1 TO

6 MAR/12

ALL

1 TO

4 DEC/14

51 TO

62

1 TO

5 DEC/14

63 TO

65

1 TO

4 MAR/14

ALL

1 TO

6 DEC/14

51 TO

62

1 TO

6 DEC/14

63 TO

65

1 TO

3 DEC/14

ALL

1 TO

6 DEC/14

ALL

1 TO

4 DEC/14

ALL

1 TO
1 TO
1 TO

4 MAR/11
3 DEC/14
4 MAR/14

59 TO
63 TO
59 TO

REVISION NO 12 - MAR/15

30-61-61-DVI-10000-001 DETAILED VISUAL INSPECTION AND CLEANING OF


PROP ANTI-ICING SYSTEM
30-61-61-RAI-10000-001 REMOVAL/INSTALLATION OF
ANTI-ICING PROPELLER
BRUSH BLOCK
30-61-61-RAI-10010-001 REMOVAL/INSTALLATION OF
PROPELLER BRUSHES
30-61-81-RAI-10000-001 REMOVAL/INSTALLATION OF
CURRENT TRANSFORMER
30-61-82-RAI-10000-001 REMOVAL/INSTALLATION OF
PROPELLER CONTACTOR
30-81-00-FUT-10000-002 FUNCTIONAL TEST OF
ICE DETECTOR
30-81-00-OPT-10000-001 OPERATIONAL TEST OF
ICE DETECTOR
30-81-00-OPT-10000-002 OPERATIONAL TEST OF
ICE DETECTOR
30-81-71-RAI-10000-001 REMOVAL AND INSTALLATION
OF ICE DETECTOR
30-82-00-OPT-10000-002 OPERATIONAL TEST OF ANTI
ICE
ADVISORY SYSTEM
30-82-00-OPT-10000-003 OPERATIONAL TEST OF ANTI
ICE
ADVISORY SYSTEM
30-83-00-DVI-10000-001 DETAILED VISUAL
INSPECTION OF LIGHTED
ICING INDICATOR
30-83-11-RAI-10000-001 REMOVAL/INSTALLATION OF
ICE VISUAL INDICATOR
30-83-11-RAI-10010-001 REMOVAL/INSTALLATION OF
ICE EVIDENCE PROBE LAMP
30-84-00-OPT-10000-001 OPERATIONAL TEST OF APM
30-84-00-OPT-10000-002 OPERATIONAL TEST OF APM
30-84-00-RAI-10000-002 REMOVAL AND INSTALLATION
OF APIU

AH

62
65
62

6
MAR/15