You are on page 1of 6

SOLENOID VALVES

3/2

redundant, direct operated


basic flow, balanced poppet
1/4

Series

327

FEATURES
The redundant solenoid valves are recommended for fail safe pilot applications
combining high flow, wide pressure range and absence of minimum operating
pressure
When the redundant valve controls an actuator, the actuator remains in position
as long as one of the two solenoid valves (coils) is energized. To exhaust the
actuator both solenoids have to be de-energized
PTFE rider rings and graphite-lled PTFE seals reduce friction and eliminate
sticking
Coils used in metal enclosures have class H insulation materials
Dedicated execution for low power
Dedicated execution for extreme low ambient temperatures
Peak voltage suppression diodes are standard in DC solenoids with metal
enclosures
The solenoid valves satisfy all relevant EC Directives
Environmental NACE compliant and certied vibration resistant in combination
with WSCR solenoids

GENERAL

Differential pressure
Maximum viscosity
Response times

0 - 10 bar [1 bar = 100kPa]


65cST (mm2/s)
75 - 100 ms (1)

uids (2) ()

temperature range (TS)(3)

seal materials ()

air, inert gas, water, oil

-20 to +120C
-40 to + 40C
-60 to + 60C

FPM (uoroelastomer)
VMQ (sillicone)
(F)VMQ ((uoro)sillicone)

3
2

Energising time for Ex i version booster coils will be < 2 sec (NFIS, WSNFIS and WSCRIS)
(2)
Air / inert gas only for Ex i version (NFIS, WSNFIS and WSCRIS)
(3)
Can be limited by the operator ambient temperature range for explosion proof solenoids
(1)

MATERIALS IN CONTACT WITH FLUID

() Ensure that the compatibility of the uids in contact with the materials is verified

Brass body
Brass
Stainless steel
Stainless steel
Stainless steel
Stainless steel
FPM, VMQ or (F)VMQ
PTFE

Body
Stem
Core tube
Core and plugnut
Springs
Sealings & poppets
Rider ring

Stainless steel body


AISI 316L SS
Stainless steel
Stainless steel
Stainless steel
Stainless steel
FPM, VMQ or (F)VMQ
PTFE

BP
MP
RP
LP
0,5 - 1,8W

3,6W - 3,7W

5,7W - 5,8W

10,0W-11,6W

Low
power

Reduced
power

Medium
power

Basic
power

POWER LEVELS - cold electrical holding values (watt)

SPECIFICATIONS

operating pressure
prefix optional solenoids
differential (bar) power
level NEMA
ATEX / IECEx
max. (PS)
IP65
7&9
Ex d
Ex i
Ex e mb
Ex mb
min. air/water ()
(mm) (m3/h) (l/m)
~/=
~/=
EF (3) NF WSCR NFIS WSCRIS EM WSCREM PV
SC

ow
pipe orifice
coefficient
size size
Kv

basic
catalogue
number
brass

stainless st.

U - Universal, FPM sealings and poppets (minimum uid temperature -20C) (4)
1/4
1/4
1/4
1/4

5,7
5,7
5,7
5,7

0,3
0,3
0,3
0,3

5,0
5,0
5,0
5,0

0
0
0
0

10
10
10
10 (2)

BP
MP
RP
LP

327B051
327B251
327B151
327B351

327B052
327B252
327B152
327B352

327B061

327B062

327B261
327B161
327B361

327B262
327B162
327B362

U - Universal, VMQ sealings and poppets (minimum uid temperature -40C) (4)
1/4

5,7

0,3

5,0

10

BP

1/4
1/4
1/4

5,7
5,7
5,7

0,3
0,3
0,3

5,0
5,0
5,0

0
0
0

10
10
10 (2)

MP
RP
LP

Select 8 for NPT ANSI 1.20.3 or Select G for ISO G(228/1)


(2)
(4)

Available feature in DC only


- Not available
Available feature
Air/inert gas only for Ex i version (NFIS, WSNFIS and WSCRIS) (3) Prefix EF and EV should always be used in conjunction with change letter H in the basic number
(5)
For maximum ambient temperature check operator ambient temperature range on page 3
-60C execution available on request

All leaflets are available on: www.asconumatics.eu


PIC-12-10-GB

80402GB-2016/R01

U - Universal, (F)VMQ sealings and poppets (minimum uid temperature -50C) (4) (5)

SERIES 327
PRODUCT SELECTION GUIDE

PREFIX TABLE
1
E
E
E
N
P
S
W
N
W
W
W
W
W
W
W

prefix
description
2 3 4 5 6 7
F
Explosionproof - NEMA 7, 9 - Zinc plated steel conduit
V
Explosionproof - NEMA 7, 9 - 316 SS conduit
M
Waterproof IP66/67 - Metal enclosure (EN/IEC 60079-7,-18 and -31)*
E T
Threaded conduit/hole (M20 x 1,5)
F
Flameproof - Aluminium (EN/IEC 60079-1, 60079-31)*
V
Encapsulated epoxy moulded (EN/IEC 60079-18)*
C
Solenoid with spade plug connector (EN/IEC 60730)
P
Waterproof IP67 - Metal enclosure
F
I S
I.S. with Aluminium IP67 enclosure (EN/IEC 60079-11+31)*
S
Waterproof IP67 - 316 SS enclosure
S C R
Flameproof 316L SS (EN/IEC 60079-0+1+31)*
S C R E M
Increased Safety / Encapsulated 316L SS (EN/IEC 60079-0+7+18+31)*
S C R I S
Intrinsically Safe 316L SS (EN/IEC 60079-0+11+31)*
S E M
Waterproof IP66/67 - 316 SS enclosure (EN/IEC 60079-7,-18 and -31)*
S N F I S
I.S. with 316L SS IP67 enclosure (EN/IEC 60079-11+31)*
S N F
Flameproof - 316L SS (EN/IEC 60079-1, 60079-31)*
T
Threaded conduit (1/2" NPT)
H C
Class H - Battery charging circuit
X Other special constructions

power level
LP RP MP BP

SUFFIX TABLE
suffix
1 2 3 4 5
N V
V
C O

description
FPM (fluoroelastomer) and parts cleaned for oxygen service
FPM (fluoroelastomer)
Epoxy coating on all external surfaces

power level
LP RP MP BP

Available feature
Available feature in DC only
- Not available
* ATEX/IECEx valves using these solenoids are approved according to EN 13463-1 (non electrical)
(1)
Functional Safety certification is not applicable with this feature

STEP 1
Select basic catalogue number,
including pipe thread indentification
letter. Refer to the specifications table
on page 1.
Example: 8327B051
STEP 2
Select prefix (combination). Refer to
the specifications table on page 1 and
the prefix table on page 2, respect the
indicated power level.
Example: NF
STEP 3
Select suffix (combination) if required.
Refer to the suffix table on page 2,
respect the indicated power level.
Example: CO
STEP 4
Select voltage. Refer to standard
voltages on page 3.
Example: 230V / 50/60 Hz
STEP 5
Final catalogue / ordering number.
Example:
NF 8327B051 CO 230V / 50/60 Hz

ORDERING EXAMPLES VALVES:


SC
WSEMT
NFET
WSEM
NF
WSCR
EM
PV
EF

OPTIONS & ACCESSORIES


spare part kit no.(2)
~/=
C123670
C123670
C131237
C131237
C132251
C132251
C132253
C132253
C132251
C132251
C132253
C132253
C132443
C132443
C132444
C132444

mounting
bracket

Select 8 for NPT ANSI 1.20.3 or select G for ISO G(228/1)


Standard prefixes/suffixes are also applicable to kits
Mounting holes in body

(2)

All leaflets are available on: www.asconumatics.eu


12-10-2

327B051
327B052
327B051
327B052
327B261
327B152
327B251
327B062
327H152

CO
CO
CO
CO
CO
CO

24V / DC
24V / DC
230V / 50/60 Hz
24V / DC
24V / DC
24V / DC
230V / 50/60 Hz
24V / DC
240V / 50/60 Hz

prefix (3)
pipe thread
basic number (3)

voltage
suffix

ORDERING EXAMPLES KITS:


WS
EM
PV
EF
prefix
basic number

C131237 (4)
C123670
C131237
CO
C123670

suffix

Prefix EF and EV should always be used in conjunction with



change letter H in the basic number
(4)
Basic kit number applies to SC coil construction

Because of the nature of redundant valves (2x solenoid) the

spare part kits have to be ordered 2x
(3)

80402GB-2016/R01

catalogue
number
SC 327B051
SC 327B052
SC 327B061
SC 327B062
SC 327B151
SC 327B152
SC 327B161
SC 327B162
SC 327B251
SC 327B252
SC 327B261
SC 327B262
327B351
327B352
327B361
327B362

8
G
G
G
8
G
8
8
G

SERIES 327
EXPLANATION OF TEMPERATURE RANGES OF SOLENOID VALVES
Valve temperature range
Operator ambient temperature range
Total temperature range

The valve temperature range (TS) is determined by the selected seal material, the temperature
range for proper operation of the valve and sometimes by the uid (e.g. steam)
The operator ambient temperature range is determined by the selected power level and the
safety code
The temperature range of the complete solenoid valve is determined by the limitations of both
temperature ranges above

ELECTRICAL CHARACTERISTICS

Coil insulation class H


Electrical safety
IEC 335
Standard voltages (1)
DC (=) 24V - 48V; Allowable voltage variation 10%

AC (~) 24V - 48V - 115V - 230V/50/60Hz; Other voltages are available on request
prefix
option

operator
power ratings
ambient
inrush holding hot/cold temperature
~
~
=
range
(VA) (VA) (W)
(W)
(C)(1)

electrical
enclosure
protection
(EN 60529)

safety code

replacement coil / kit


~

230V/50/60 Hz

24V/DC

type(2)

Basic power (BP)


SC
WP/WS
NF/WSNF
EM/WSEM
PV
EF/EV

10,0
10,0
10,0
10,0
12,0

10,0
10,0
10,0
10,0
12,0

10,0
10,0
10,0
10,0
12,0

9,0/11,2
9,0/11,2
9,0/11,2
9,0/11,2
9,0/11,2
9,3/11,6

-40 to +55
-40 to +55
-60 to +40/60
-40 to +40
-40 to +55
-40 to +52/40

EN 60730
EN 60730
II2G Ex d IIC Gb T6/T5, II2D Ex tb IIIC Db
II2G Ex e mb IIC Gb T3, II2D Ex tb IIIC Db
II2G Ex mb IIC Gb T4, II2D Ex mb IIIC Db
NEMA type 7 and 9

IP65, moulded
IP67, steel /SS
IP66/67, alu./SS
IP66/67, steel /SS
IP67, moulded
NEMA 4X

123664-017
400915-017
400915-017
400915-017
276002-058D

400425-142
400913-142
400913-142
400913-142
- (3)
238714-006D

01
03
05
03
07
08

5,8
5,8
5,8
5,8
5,8
5,8

5,2/5,7
5,2/5,7
5,2/5,7
5,2/5,7
5,2/5,7
5,2/5,7

-40 to +90
-40 to +90
-60 to +40/75
-60 to +90
-60 to +60/75/90
-40 to +40/75

EN 60730
EN 60730
II2G Ex d IIC Gb T6/T5/T4, II2D Ex tb IIIC Db
II2G Ex d IIC Gb T6/T4, II2D Ex t IIIC Db
II2G Ex e mb IIC Gb T6/T4, II2D Ex tb IIIC Db
II2G Ex e mb IIC Gb T5/T4, II2D Ex tb IIIC Db

IP65, moulded
IP67, steel /SS
IP66/67, alu./SS
IP66/67, SS
IP66/67, SS
IP66/67, steel /SS

400924-297
400921-297
400921-297
400962-297
400962-297
400921-297

400923-442
400914-442
400914-442
400961-442
400961-442
400914-442

02
04
05
06
06
04

3,2/3,6
3,2/3,6
3,2/3,6
3,2/3,6
3,2/3,6
3,2/3,6

-40 to +55
EN 60730
-40 to +55
EN 60730
-60 to +60
II2G Ex d IIC Gb T6, II2D Ex tb IIIC Db
-60 to +40/60/90 II2G Ex d IIC Gb T6/T5/T4, II2D Ex t IIIC Db
-60 to +40/60/90 II2G Ex e mb IIC Gb T6/T5/T4, II2D Ex tb IIIC Db
-40 to +40/55
II2G Ex e mb IIC Gb T6/T5, II2D Ex tb IIIC Db

Medium Power (MP)


SC
WP/WS
NF/WSNF
WSCR
WSCREM
EM/WSEM

5,8
5,8
5,8
5,8
5,8
5,8

5,8
5,8
5,8
5,8
5,8
5,8

Reduced Power (RP)(4)


SC
WP/WS
NF/WSNF
WSCR
WSCREM
EM/WSEM

3,7
3,7
3,7
3,7
3,7
3,7

3,7
3,7
3,7
3,7
3,7
3,7

3,7
3,7
3,7
3,7
3,7
3,7

IP65, moulded
IP67, steel /SS
IP66/67, alu./SS
IP66/67, SS
IP66/67, SS
IP66/67, steel /SS

- (4)
- (4)
- (4)
- (4)
- (4)
- (4)

400923-042
400914-242
400914-242
400961-242
400961-242
400914-242

02
04
05
06
06
04

IP66/67, alu./SS
IP66/67, SS
IP66/67, SS
IP66/67, alu./SS
IP66/67, SS
IP66/67, alu./SS

- (5)
- (5)
- (5)
- (5)
- (5)
- (5)

400914-542
400961-542
400961-542
429013-001
429013-001
429013-001

05
06
06
05
06
05

Low Power (LP)(5)


NF/WSNF 1,85
WSCR
1,85
WSCREM 1,85
NFIS (6)
0,5
WSCRIS
0,5
WSNFIS
0,5

1,85 1,85 1,5/1,8 -60 to +55


1,85 1,85 1,5/1,8 -60 to +55
1,85 1,85 1,5/1,8 -60 to +55
0,5 0,5
0,5
-40 to +60
0,5 0,5
0,5
-40 to +60
0,5 0,5
0,5
-40 to +60

Temperature range can be limited by sealings


AC (~) limited to 127V/50/60Hz or 125V/DC
- Not available

II2G Ex d IIC Gb T6, II2D Ex tb IIIC Db


II2G Ex d IIC Gb T6, II2D Ex t IIIC Db
II2G Ex e mb IIC Gb T6, II2D Ex tb IIIC Db
II2G Ex ia IIC T6 Gb, II2D Ex tb IIIC Db
II2G Ex ia IIC T6 Gb, II2D Ex tb IIIC Db
II2G Ex ia IIC T6 Gb, II2D Ex tb IIIC Db

(1)

(2)

(4)

(5)

Refer to the dimensional drawings on page 4 and 5


Only available in 24V/DC

(3)
(6)

Multiple coil kits are available under ATEX/IECEx, contact us


Shall be protected against any impact or friction, see the
installation conditions given in the I&M sheet

ELECTRICAL CONNECTIONS
prefix
SC
WP, WS, EM, WSEM, NFIS, WSNFIS, WSCRIS

connection
Spade plug connector with cable gland EN175301-803A (ISO 4400) for cables
with an outer diameter from 6 to 10 mm
M20 plastics cable gland for cables with an outer diameter from 7 to 12 mm.

WSCREM

M20 316 SS cable gland for cables with an outer diameter from 7,2 to 11,7 mm.

NF, WSNF, WSCR, NFTIS, WSNFTIS

1/2" NPT threaded cable entry. Enclosures are supplied without cable gland

NFET, WSNFET, NFETIS, WSNFETIS

M20 x 1,5 threaded cable entry. Enclosures are supplied without cable gland
80402GB-2016/R01

All leaflets are available on: www.asconumatics.eu


12-10-3

SERIES 327
ADDITIONAL OPTIONS

Direct mount / pad mount construction according to NAMUR recommendations


Ex mb/mD (prefix "PV") solenoid can be supplied with various cable lengths
Compliance with "UL", "CSA" and other local approvals available on request
Special moulded-in solid state components for peak voltage suppression and/or rectification (four diode bridge)
-60C execution available on request

INSTALLATION

Multi language installation/maintenance instructions are included with each valve


The solenoid valves can be mounted in any position without affecting operation
The mounting holes are provided in the valve body
Threaded pipe connection identifier is 8 = NPT (ANSI 1.20.3); G = G (ISO 228/1)
Declarations of conformity are available on request
Ex e mb Prefix "EM" and Ex ia Prefix "NFIS/WSCRIS"execution: solenoid enclosure has a cable gland with integral strain relief
for cables with an o.d. from 7 to 12 mm and is provided with an internal and external connection facility for an earthing or
bonding conductor
Ex d Prefix "NF/WSNF/WSCR" enclosure is provided with a 1/2" NPT threaded entry hole, M20 x 1,5 (prefix "ET") is optional.
These are supplied without cable gland
All DC solenoids with metal enclosure are provided with switch-off peak voltage suppression diodes
To comply with IEC 61508 (SIL) the valves must be provided with a specific exhaust protector (as shown on page 6) or equal

DIMENSIONS (mm), WEIGHT (kg)


TYPE 01:

TYPE 02:

Epoxy moulded
SC: IEC 335 / ISO 4400

Epoxy moulded
SC: IEC 335 / ISO 4400

327B051 / B052 / B061 / B062

327B151 / B152 / B161 / B162 / B251 / B252 / B261 / B262




360

360









TYPE 03:

TYPE 04:

Metal, epoxy coated / AISI 316 SS


WP / WS: IEC 335
EM / WSEM: EN/IEC 60079-7+18+31

Metal, epoxy coated / AISI 316 SS


WP / WS: IEC 335
EM / WSEM: EN/IEC 60079-7+18+31

327B051 / B052 / B061 / B062

327B151 / B152 / B161 / B162 / B251 / B252 / B261 / B262




360

360








All leaflets are available on: www.asconumatics.eu


12-10-4

80402GB-2016/R01



SERIES 327
DIMENSIONS (mm), WEIGHT (kg)
TYPE 05:

TYPE 06:

Aluminium, epoxy coated / AISI 316L SS


NF / WSNF
: EN/IEC 60079-1, 60079-31
NFIS / WSNFIS : EN/IEC 60079-11, 60079-31

AISI 316L SS
WSCR
: EN/IEC 60079-0, 60079-1, 60079-31
WSCREM : EN/IEC 60079-0, 60079-7, 60079-18,
EN/IEC 60079-31
WSCRIS : EN/IEC 60079-0, 60079-11, 60079-31

327 B051 / B052 / B061 / B062 / B151 / B152 / B161 / B162 /


B251 / B252 / B261 / B262 / B351 / B352 / B361 / B362





A




327 B152 / B162 / B252 / B262 / B352 / B362

G
F






5,5

12




36




27
37

TYPE 07:

TYPE 08:

Epoxy encapsulated
PV: EN/IEC 60079-18

Epoxy encapsulated
EF and EV: NEMA type 7, 9 / ICS-6 ANSI

327B051 / B052 / B061 / B062







327H001 / H002 / H011 / H012
























01
02
03
04
05
05
06
07
08

SC
SC
WP, WS, EM, WSEM
WP, WS, EM, WSEM
NF, WSNF
NF, WSNF, NFIS, WSNFIS
WSCR, WSCREM, WSCRIS
PV
EF, EV

power level

weight

BP
MP/RP
BP
MP/RP
BP/MP/RP
LP
MP/RP/LP
BP
BP

45
50
76
76
97
97
92
45
50

91
86
86
90
135
145
137
97
97

205
194
194
201
248
268
252
171
173

93
97
120
120
102
102
116
72
77

65
68
82
82
54
54
75
67
51

66
59
61
63
160
170
161
45
122

23
23
23
23
101
111
103
121
62

102
97
97
100
23
23
23
23
23

1,55 kg
1,65 kg
1,60 kg
1,70 kg
4,70 kg
4,90 kg
3,10 kg
1,70 kg
1,70 kg

80402GB-2016/R01

type prefix/option





All leaflets are available on: www.asconumatics.eu


12-10-5

SERIES 327
SECTIONAL DRAWING
2

A
3

1
3
2

Schematic presentation of
the redundant valve

Execution : Reduced Power

Bracket kit no.: C139824


contains: Stainless steel
304 SS screws and bracket

All leaflets are available on: www.asconumatics.eu


12-10-6

PIC-12-0010-GB -- Availability, design and specifications are subject to change without notice. All rights reserved.