You are on page 1of 11

ANLISIS DE PERFORMANCE DE

REHERVIDOR KETTLE
CURSO: SIMULACIN Y DIMENSIONAMIENTO DE INTERCAMBIADORES DE
CALOR
CAPTULO 4

Ingeniero de Procesos - Luis Torres Melchor

05/11/2016

ASPEN EXCHANGER DESIGN & RATING FAMILY

Ingeniero de Procesos - Luis Torres Melchor

05/11/2016

ASPEN SHELL & TUBE EXCHANGER


CASE 2: ANALYZE THE PERFORMANCE OF A KETTLE REBOILER

Ingeniero de Procesos - Luis Torres Melchor

05/11/2016

ASPEN SHELL & TUBE EXCHANGER


CASE 2: ANALYZE THE PERFORMANCE OF A KETTLE REBOILER
KEY DESIGN PARAMETERS ON KETTLE REBOILERS
RECIRCULATION RATIO: THE RATIO OF THE RECIRCULATING FLOW AROUND THE BUNDLE AND THE INLET
FLOW
QUALITY AT THE TOP OF THE BUNDLE: BECAUSE OF RECIRCULATION, THE QUALITY AT THE BUNDLE EXIT WILL
BE DIFFERENT FROM THE QUALITY OF THE STREAM LEAVING THE EXCHANGER
ENTERTAINMENT FRACTION: THE MASS OF LIQUID ENTRAINED IN THE VAPOR PER UNIT MASS OF VAPOR

Ingeniero de Procesos - Luis Torres Melchor

05/11/2016

ASPEN SHELL & TUBE EXCHANGER


CASE 2: ANALYZE THE PERFORMANCE OF A KETTLE REBOILER
OBJECTIVE
TO SIMULATE A KETTLE REBOILER TO ANALYZE THE PERFORMANCE OF THE EXCHANGER
EVALUATE THE RECIRCULATION RATIO AND ENTRAINMENT FRACTION

CONTAINS THE FOLLOWING TASKS


SIMULATE A K-SHELL
ENTER LIQUID/VAPOR ONLY OUTLET NOZZLES DETAILS

Ingeniero de Procesos - Luis Torres Melchor

05/11/2016

ASPEN SHELL & TUBE EXCHANGER


CASE 2: ANALYZE THE PERFORMANCE OF A KETTLE REBOILER
UNITS OF MEASURE: SI
CALCULATION MODE: SIMULATION
HOT FLUID: TUBE SIDE (STEAM)
COLD FLUID: SHELL SIDE (HEXANE)
HOT SIDE APPLICATION: CONDENSATION
COLD SIDE APPLICATION: VAPORIZATION
VAPORIZER TYPE: KETTLE

Ingeniero de Procesos - Luis Torres Melchor

05/11/2016

ASPEN SHELL & TUBE EXCHANGER


CASE 2: ANALYZE THE PERFORMANCE OF A KETTLE REBOILER
PHYSICAL PROPERTY DATA
HOT STREAM
SELECT COMTHERMO PHYSICAL PROPERTY PKG
SELECT WATER
SELECT PENG ROBINSON AS THE PROPERTY METHOD
SPECIFY A TEMPERATURA RANGE FROM 160C TO 100C

Ingeniero de Procesos - Luis Torres Melchor

05/11/2016

ASPEN SHELL & TUBE EXCHANGER


CASE 2: ANALYZE THE PERFORMANCE OF A KETTLE REBOILER
PHYSICAL PROPERTY DATA
COLD STREAM
SELECT COMTHERMO PHYSICAL PROPERTY PKG
SELECT HEXANE
SELECT PENG ROBINSON AS THE PROPERTY METHOD
SPECIFY A TEMPERATURA RANGE FROM 100C TO 160C

Ingeniero de Procesos - Luis Torres Melchor

05/11/2016

ASPEN SHELL & TUBE EXCHANGER


CASE 2: ANALYZE THE PERFORMANCE OF A KETTLE REBOILER
GEOMETRY SUMMARY
SELECT THE TEMA TYPE AS AKU

Ingeniero de Procesos - Luis Torres Melchor

05/11/2016

ASPEN SHELL & TUBE EXCHANGER


CASE 2: ANALYZE THE PERFORMANCE OF A KETTLE REBOILER
EXCHANGER GEOMETRY
KETTLE ID: 1750MM
N SUPPORTS: 6
TUBESIDE NOZZLES: 320MM, 220MM, 400MM
SHELL SIDE NOZZLES: 345MM, 152MM

RUN CONTROL
CLICK RUN
SAVE CASE: 3_KETTLE_REBOILER

Ingeniero de Procesos - Luis Torres Melchor

05/11/2016

10

ASPEN SHELL & TUBE EXCHANGER


CASE 2: ANALYZE THE PERFORMANCE OF A KETTLE REBOILER
RESULT SUMMARY
REVIEW WARNING AND MESSAGES
RECORD THE FOLLOWING RESULTS

BAFFLE SUPPORT
ADD U BEND SUPPORT

CHECK IF YOU HAVE VIBRATION WARNING YET


SET ADEQUATE SHELL AND TUBE TEMPERATURA RATING TO ELIMINATE WARNING MESSAGES 1636 AND 1637
REVIEW THE OPERATION WARNING 1387, WHAT CHANGES WOULD YOU DO?

Ingeniero de Procesos - Luis Torres Melchor

05/11/2016

11