MANUFACTURER FILE
" FINAL "
Customer :
Vessel
Shipyard
Our ref.
759197
Please remind this AUXITROL Ref. N for spare parts and any inquiries.
Division of
Auxitrol
Technologies
AUXITROL S.A.
5, alle Charles Path
18941 Bourges Cedex 9
France
Tel : + 33 (0) 1 49 11 65 75
Fax : + 33 (0) 1 49 11 65 76
E-Mail : system.dir@auxitrol.com
http://www.auxitrol.com
An Esterline
Technologies
Company
SYSTEMS&SENSORS
04/06/02
Page 1/3
MANUFACTURING FILE
FINAL
SUMMARY
1) SYNOPTIC.........................................................................................759197-00
SCOPE OF SUPPLY .........................................................................759197-03
2) DRAWINGS
2-1 Cargo Tanks Level
TA840 Radar Level Transmitter ...............................................................M13002
Flexible kit BV2.........................................................................................M13145
Flexible kit BV3.........................................................................................M13144
BV2 Plug ..................................................................................................M13156
Rotative Hinge ..........................................................................................M13142
TA840 Fixing bolts....................................................................................M13143
Gore Tex Gasket Installation ....................................................................M12734
TA840 Installation of Cable protection......................................................M13549
TA840 Deck Socket..................................................................................M15088
Deck Socket Installation ..........................................................................M12881
TA840 Beam Propagation requirement ....................................................M13267
FRANCE : Auxitrol S.A. Paris & Bourges SPAIN : Auxitrol Iberico - Madrid
Headquarters : 5, alle Charles Path 18941 Bourges Cedex 9 France
Auxitrol S.A. - 602 023 251 R.C.S. Bourges
Division of
Auxitrol
Technologies
AUXITROL S.A.
5, alle Charles Path
18941 Bourges Cedex 9
France
Tel : + 33 (0) 1 49 11 65 75
Fax : + 33 (0) 1 49 11 65 76
E-Mail : system.dir@auxitrol.com
http://www.auxitrol.com
An Esterline
Technologies
Company
SYSTEMS&SENSORS
04/06/02
Page 2/3
Division of
Auxitrol
Technologies
AUXITROL S.A.
5, alle Charles Path
18941 Bourges Cedex 9
France
Tel : + 33 (0) 1 49 11 65 75
Fax : + 33 (0) 1 49 11 65 76
E-Mail : system.dir@auxitrol.com
http://www.auxitrol.com
An Esterline
Technologies
Company
SYSTEMS&SENSORS
04/06/02
Page 3/3
3) TECHNICAL DATA
3.1 - Product Technical Data Questionnaire ....................................759197-04
3.2 - I / O and Wiring List ...................................................................759197-12
4) TECHNICAL MANUALS
TA840 System Installation Manual .................................................... CB322508A
TA840-I Fuses location ..................................................................... M15061
TA840-I Safety Module Communication protocol .............................. DT2395E
INC840 INCLINOMETER User Manual............................................. CB322533A
MICATRANS A/D Installation and Maintenance Manual ................... CB322514
CRI840 19 Indicating rack (included in Micatrans AD) ..................... MT5082
Lidec Installation Manual................................................................... NT401
PL3700 Installation Manual ............................................................... MI5090
PL3700 Maintenance Manual............................................................ MM5090
5) CERTIFICATES
5.1 - Intrinsic Safety certificates
Certificate of Conformity LCIE TA840 System................................... 95.D6147X
Certificate of Conformity LCIE T901P transmitter.............................. 96.D6083X
Certificate of Conformity LCIE TA840 Radar..................................... 95.D6119X
Certificate of Conformity LCIE TA840 Interface................................. 95.D6118X
Certificate of Conformity LCIE PL3700.............................................. 00 E6113X
Certificate of Conformity LCIE Lidec ................................................. 92.C6107X
5.2 - Type Approval certificates
BV Type Approval TA840 System ..................................................... 6598/B0 BV
BV Type Approval PL3700 ................................................................ 11058/A0 BV
BV Type Approval MICATRANS A/D ................................................ 05135/C0 BV
BV Type Approval Lidec .................................................................... 4930/C0 BV
FRANCE : Auxitrol S.A. Paris & Bourges SPAIN : Auxitrol Iberico - Madrid
Headquarters : 5, alle Charles Path 18941 Bourges Cedex 9 France
Auxitrol S.A. - 602 023 251 R.C.S. Bourges
TA840-I
TA840-I
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud Cedex
France
Tel : + 33 (0) 1 49 11 65 75
Fax : + 33 (0) 1 49 11 65 76
E-Mail : systemes.dir@auxitrol.com
http://www.auxitrol.com
An Esterline
Technologies
Company
SYSTEMS&SENSORS
IZAR FENE
FPSO BLOCK 137B
759197-03
page 1 / 2
SCOPE OF SUPPLY
Item
1
1
1
1
1
1
1
Designation
Cargo Level
TA 840 Radar Level Transmitter - Intrinsically Safe
Radar Fixation Kit (Bolt)
Gasket in Gore-tex for Radar TA 840
Grounding Braid & Hinge Fixation for Radar TA 840
Flexible Conduit KIT BV2 for Bus output from Radar
TA 840
Flexible Conduit KIT BV3 for Temperature Input to
Radar TA 840
Radar SS Deck Trunk
Cargo Temperature
T901-P31A Temperature (3 Probes) and
Vapour Pressure Transmitter with
Flexible Conduit & Gasket
Total Sensor Length
Ballast, Draft and Service Tanks
PL3700 Level Transmitter - Side Mounting with
PN16DN40 Flange
Cable Lenght in m = 28
Qty
14
14
14
14
14
14
14
14
490
15
10
10
6
6
6
Monitoring
TA 840I Safety Module - Base Unit
TA 840I Safety Module - Extension Unit
TA 840I Safety Block in 220 V ac
1
1
15
7
7
1
1
CHINA : Auxitrol S.A. Shanghai FRANCE : Auxitrol S.A. Paris & Bourges NORWAY : Auxitrol Norway Oslo
SPAIN : Auxitrol Iberico - Madrid
Headquarters : 5, alle Charles Path 18941 Bourges Cedex 9 France
Auxitrol S.A. - 602 023 251 R.C.S. Bourges
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud Cedex
France
Tel : + 33 (0) 1 49 11 65 75
Fax : + 33 (0) 1 49 11 65 76
E-Mail : systemes.dir@auxitrol.com
http://www.auxitrol.com
An Esterline
Technologies
Company
SYSTEMS&SENSORS
page 2 / 2
14
1
3
2
3
3
2
28
4
4
2
14
28
4
CHINA : Auxitrol S.A. Shanghai FRANCE : Auxitrol S.A. Paris & Bourges NORWAY : Auxitrol Norway Oslo
SPAIN : Auxitrol Iberico - Madrid
Headquarters : 5, alle Charles Path 18941 Bourges Cedex 9 France
Auxitrol S.A. - 602 023 251 R.C.S. Bourges
2-1
2-2
2-3
2-4
2-5
ru
'.J
id
0
=.om"'o-Ul"""N-
~I
3
"lJ
m"'o-Ul"""N-.o~"'a-Ul"""N-
"'+0~;;1;;1-t-t-t-t"tJ
~~~
~UI<~~~~~~~
~;s;soo
m_~
--.
",-1
>
<01
~M
~~~
~ ;;1-t ~ -t;;1B~~~~~~~ ~~ ~ ~~
~~ ~
;E~~~~~;2;2 aa
"N
-~"""NNiApAJ:.OJ:. ~~
~!:;J~- ~~-
r-:"""""NNi+
UlO< 1 + 1 +
9;
<
""",~-<-<-<-<
NN-1+1+3--'-'
"0.
ma
~
~
~
~
~
0
::T
CD
:Jo'
(XJ
~
0
"e
:c;(x)
~-l::..
---
~U)
~-<
ZU)
'"""'
'-'.1
.--,::=0""
-'--'
-1
o~
3,-i
b'
~
1.1
G)
~8
~-:z
a.~ 0
-1::
=
~
CD
rTl
r+
CD V"J
3
..
on
n
ii
:.
::::0
on
5
;;-
Z-O
UI
0
-5. ~
9.. '<
0-
n>,
"""N-'"
no
rTl
~g~~-
C:JrTl~
~;;or-n
"
rTl
n
nZ~
F-IG")n~
-1
,.-1
0
~
G")
- -
m~-;:;:-n
-u->o:t:
Z-ILO
c:a
~
0
,-i
:Jo'
'-'
CXJ
~
~
e~ ..
0 cn
cgcg,< u->
;;o;;o~o
--c~g;;o
offi-Ia.V5
~;;o
I::!~
00
3..
-"t:
~~"
~~
-1
~
~~~
c!:j-<
z
- Il 1~~~~
&.
1::
CD
Z
~
~~
Cl'1
z
n
1+ 1+
~
ro
r-%
-t
-,
Z..'"
c!:jc
rTl
1::='
n~:g
cr-
;:::1
r--<
-i
-<
~
~~
CJ
ri1
;.,
CC")
z 0
'"
O
1
Il
0
-,
UI
0
~
1"'
~~
1+1+
",
I~
l rl
0
>
;.,
~
~
~II
UI-I
0
--
,-i
0
0
lN
!"Tl
-u
U)
OfTI3
o:z:
'-"
cc
-..J
-;;0
=--,
U)
-,
CD
UI
t-..)
-'"'"
~C:=i
fTI
rTl ~ '-"
_::c
g~'"'"
--- 1 -'t-..)
-.0
,-- c
~
a.1l,
~ g:
0
~
' ~I
E. ,-i
'-~In
CD
"'---'~
= l,
l '
:-n
: -n
c
ln
r+
0
:
:
;
UI
C
-,
-,:,
-,:,
'<
::c
C(?
t-..)
~
~
0
-~
r;r
ln
-.
~
.:!<:!
1
~I;::!
0
Z
ln
cn
-
:
:
'1
.",.
0
Q
~
8
0
0
Z
-i
~
0
r;;
m
a.
~
C
I~
,...
cn-,...
l, 'iD"
ln ln ,l
-,c --,
",,---,
CD
--1
~
3
CD
-,
~ ,
,~
'-"
1::;
"U;
"U.
':<:";
'-";
'<"
3
'a.-'o'
' ~
:
"'---'
~
~~ ~
~
= l, 3
-I
()
V"J ~
~
~. ii'
.0x
x -.
~
-.
Il Il
3
,.
CD
~
:T
~CD
!"Tl
:::!
Z :z:
~ ~
~!D
"""rT1
G>
>
~~0>:1:>
~
:Jo' F
--:--u->
-1 1::='
:z r:
rrTl
'"<
~ n
~
~E
~
~
~
z
n
"Tl
F;:;
:t: ~
C:J-IO
~r-~fTI
t-..):t:
3
~
c-;o
u->r- -I
""'-.1\
Il
1::='
ou->
:t:'.
(XI
~n
Con
.U:'
1\
f;;;@~
AA
Il Il
rTl
:t: C
-0
cg rTl
u->
~
~
r- r-:t:
_.r-
:;.c-~
~ t-..)
G")
~
1\ Il
~:z
0"
..
-
- 1 -1 -0
~
o~
~
Co
~on
on
_.
g.
-;0
G")
~ ~
;!:;u->
~'~
~
E
..
on
~
rm
a:
..
:;0
CDr+
.:<-::T
fN\
~
:t:
"""'
!DV"J~-,::I
c->()
> ,. 1
c->
-lU>
fTlZrT1u->;or
0
00
> :::J
-:;0<'-"
~O!"TlX!"Tl
fTI>!"Tl!"TlV5
0
0
-1 Z rT1
-I
ZC->
/)0
~;o!"TlO
~ fTI V"JO
t-..);Oo
x
V5 1::
rTl
~(JIfTlU1
fTlx
2. (JI :2: t-..) :z:
-CC'-"
- cc
3
33
r\)
t-..),
~
0
0
~
C)
Z
~C=icc:
fTI
!"Tl ~
rTl ;0
O
~
-1
:z:
>
rfTI fTI
1::='
C->V"Jc->-u
-U
rT1:;0
rTl;o
~ fTI
0
~Zc->O"Tl
-I:z:o.
!"Tl;o
!"Tl
c->
:;0 !"Tl ;0
;0
.. ZrTlzU)
;c-u>
~ 0 V"JV"J
3
c
-.
-Il~CXJ
J,(JI
33
3 3
~fTI
'-"
3 :2:
I::='~'
3::2::
t-..)G"">
'-"0
"Tl
"
~
0
~
~
0
~
~
(Jl
0"'
'--J
(X)
~~~
r-
ru
'"
,,-1
>'
w
0
:;,
,,-1
>'
cx>
0..
3 1-
_00
:;,
.-+-
-,
c
-,
ro
;U
t/)
t-.)
tN
t-.)
cn
(f>
<
-.
(f>
~<~
~o
cx>
0c:
:
c:
cn
-1 ~.
-
-0
<
roO
~
~A"
c
-,
roO
~
000
0
;U
-.
cn
cx>
~
0
1
;U
-r,
~;u
;u
iiO
0
:z
<
.-
-t
iiO
<
r:;:;
r:;:;
..
00
-=;:;
;u
0
iiO
.-
:z
.-
!! 0
00
-t
rTl
'--'"
= i!O
t-.)
tN
t-.)
t-.)
tN
t-.)
;U
t/)
;U
t/)
r
rTl
:z
G")
-t
:1:
0
"
"
rTl
rTl
,
F;:;
F;:;
0"-.J
0"-1
1\
"-1
1\
:;cn
r110
;"T1Z
N~
(.,J~
:;cn
r110
""Z
~Z
~
0
'Ci
(X)
(.,JZ
~~
',
:::!
': jlj I i
Ci)
'1
~~
ID
>
"tJ1D
zr r11
:z r11
~
'"-.'
0000'_-
~"111,+0
, r'\
~X..
0.'0'.'
~I
.~~~
::
;
:
-..
;U
~
;U
111111+0
,,-1
>'
cx>
l'~.
~~
~111111+0
1
~
~
"-.J
iI]]I
~I
wm+D
~~
iI]]I~
'iTffiii 0j
iI]]I~~
~~~
~~~
~
rTl
~
c
c:
.-+-
-..~~ ~
d~~ nJ
'-U
"'CI")
<
<
~~15 ~
~~-<
... 1
;U
rTl
>'
~-..~
,.,~x ,
",.,-.
~~~ nJ
~ .. ~
;U
:;0
< (J)
;:;, -1
~ -.J
><~ V)
~~a=
_%"0
l
~~~
"O~;
~~..
;<~~
-..r%r~~
~f
-4~
-z
~
~
-1
.-.
""
.-.
0
Z
~~
~~
ru
U1
0'1
ro
3-1
IZAR FENE
FPSO-Block 137B
759197-04
Page 1/7
TA840 Radar
Manual Sounding
Reference
Offset (+)
L2
Dec
Bon pour commande
Tank height L1
le : 25/02/02
Tank Bottom
TANK NAME
1 CO1P
2 C01S
3 C0 2P
4 C02S
5 C03P
6 C03S
7 C04P
8 CO4S
9 C05P
10 C05S
11 C06P
12 C06S
13 OIL SETTLING TANK
14 WATER SETTLING TANK
L1
(mm)
L2
(mm)
23315
23315
23315
23315
23315
23315
23315
23315
23315
23315
23315
23315
23338
23133
825
825
825
825
825
825
825
825
825
825
825
825
825
825
Offset
(mm)
+ or -403
-403
-403
-403
-403
-403
-403
-403
-403
-403
-403
-403
-457
-468
L.E.
IZAR FENE
FPSO-Block 137B
759197-04
Page 2/7
T901P-21A
H5
H4
Deck
Upper temperature probe
H1
H2
H4 : Distance
between
the
process face of
the
T901P's
flange and the
ceiling of the
tank
H3
TANK NAME
1 CO1P
2 CO1S
3 CO2P
4 CO2S
5 CO3P
6 CO3S
7 CO4P
8 CO4S
9 CO5P
10 CO5S
11 CO6P
12 CO6S
13 OIL SETTLING TANK
14 WATER SETTLING TANK
Upper
H1
(mm)
4605
4605
4655
4655
4645
4645
4625
4625
4675
4675
4655
4655
4885
4570
Middle
H2
(mm)
13935
13935
13985
13985
13980
13980
13960
13960
14005
14005
13985
13985
14160
13850
Lower
H3
(mm)
22865
22865
22915
22915
22915
22915
22890
22890
22935
22935
22915
22915
23045
22730
H4
(mm)
235
235
235
235
235
235
235
235
235
235
235
235
235
235
H5
(mm)
645
645
515
515
595
595
615
615
595
595
595
595
485
592
IZAR FENE
FPSO-Block 137B
759197-04
Page 3/7
Distance between
the process face of
the L92's flange
and the ceiling of
the tank
L3
Deck
L2
L1
TANK NAME
1 CO1P
2 CO1S
3 CO2P
4 CO2S
5 CO3P
6 CO3S
7 CO4P
8 CO4S
9 CO5P
10 CO5S
11 CO6P
12 CO6S
13 OIL SETTLING TANK
14 WATER SETTLING TANK
1133
1133
1133
1133
1119
1119
1119
1119
1133
1133
1133
1133
1117
1086
L3 (mm)
125
125
125
125
125
125
125
125
125
125
125
125
125
125
Note : L3 must be such as the housing doesn't stay under residual water
IZAR FENE
FPSO-Block 137B
759197-04
Page 4/7
Vent Pipe
PL3700
Level
Te shape
A
Keel line
DRAFT
(mm)
(mm)
Cable
length (m)
Specific
Gravity
of the
Liquid
Yes or No
NO
FORE
160
17000
30
1.025
AFT
160
17000
30
1.025
TRIM PORT
160
17000
30
1.025
TRIM STBD
160
17000
30
1.025
Zener
barrier
IZAR FENE
FPSO-Block 137B
759197-04
Page 5/7
20 mA
Maxi. tank height
(100% volume)
H3
PL3700
Level
Transmitter
H1
H2
0 - Tank bottom
Zero
line
Vent pipe
height
TANK NAME
FO DAILY N 1P
DO STORAGE N 1P
16000
150
850
26260
DO STORAGE N 1S
16000
150
850
26260
DO DAILY TANK
5500
150
850
10260
DO DAILY TANK
5500
150
850
10260
1560
90
2330
3000
100
24260
6
7
AFF FF DO
SERVICE TK
FWD FF DO
SERVICE TANK
H1 (mm) H2 (mm)
8000
150
Cable
Max.
Specific length
Gravity
Liquid
980
(m)
3
H3 (mm)
16000
850
850
IZAR FENE
FPSO-Block 137B
759197-04
Page 6/7
8
9
FWD EMERG.DG
DO TK
IG & HEALTER`S
DO DAILY TANK
10 F.O. N 1 P
11
F.O. N 1 S
2400
100
5500
150
23500
150
23500
150
850
850
980
980
7900
10260
24260
24260
NOTE : 2 TRANSMITTERS ( TANKS F.O. 1P AND F.O. 1S) WITH REMOTE BOX IN
STAINLESS STEEL.
IZAR FENE
FPSO-Block 137B
759197-04
Page 7/7
(100% volume)
H1
H3
PL3700
Level
t
itt
H2
Tank bottom
Max.
Specific
Gravity
Cable
Vent pipe
height
Liquid
length (m)
H3 (mm)
50
1000
20
21260
13500
50
3 WB FOREPEAK P
23500
150
4 WB FOREPEAK S
23500
150
5 WB TK 1P
23125
50
6 WB TK 1S
23125
50
7 WB TK 2P
23125
50
8 WB TK 2S
23125
50
9 WB AFT PEAK P
23500
50
10 WB AFT PEAK S
23500
50
Hazardous area; with zener barrier
1000
1025
1025
1025
1025
1025
1025
1025
1025
20
30
30
30
30
30
30
30
30
21260
31260
31260
23923
23923
23923
23923
24300
24300
Zero line
TANK NAME
1 FW STORAGE TK
2 FW STORAGE TK
H1 (mm) H2 (mm)
13500
IZAR FENE
759197
IZAR FENE
Vessel : FPSO BLOCK 137B
Auxitrol - SA au capital de 65 595 700 FRF - R.C.S. Bourges B 602 023 251- Siret 602 023 251 00104 - APE 332B - T.V.A. FR 90 602 023 251
Table of Contents:
2.2
3.2
Appendix 1
Page 2 / 9
756194-04A
Rev. 00
1.0
Introduction
In order for Auxitrol to be able to deliver a best operational system using Trim & Heel Level Compensation
and Volume calculation of Cargo and other tanks, it is most important to receive answers to all the
questions raised in this questionnaire. These data are used when there is an inclinometer or Draft, trim and
heel application to measure the angle of the ship lengthwise and/or breadthwise.
2.0
Cargo Tanks
2.1
Documents required
2.2
N
1
2
3
4
5
6
7
8
9
10
11
12
13
Tank Name
!
!
!
!
!
!
!
!
!
!
!
!
!
Y-Pos. (m)
X-Pos. (m)
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
Comments.
!
!
!
!
!
!
!
!
!
!
!
!
!
! : Data to be fulfilled by Yard, with respect of the sign + or Tank Name : Tank Name to be max 10 Characters.
Y-Pos. & X-Pos.: Please refer to appendix 1 for guidance on calculating these values.
All Measurements with 3 decimal digits eq. 1.098 m
Page 3 / 9
756194-04A
Rev. 00
3.0
Ballast Tanks
3.1
Documents required
3.2
N
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Tank Name
!
!
!
!
!
!
!
!
!
!
!
!
!
!
Y-Pos. (m)
!
!
!
!
!
!
!
!
!
!
!
!
!
!
X-Pos. (m)
!
!
!
!
!
!
!
!
!
!
!
!
!
!
Comments.
!
!
!
!
!
!
!
!
!
!
!
!
!
!
! : Data to be fulfilled by Yard, with respect of the sign + or Tank Name : Tank Name to be max 10 Characters.
Y-Pos. & X-Pos.: Please refer to appendix 1 for guidance on calculating these values.
All Measurements with 3 decimal digits eq. 1.098 m
Page 4 / 9
4.0
These data are required to proceed to Trim & Heel compensation of Drafts measurement.
Important note : please mention if the Trim & Heel compensation must be performed by reference to
Shell Marks or to Perpendiculars. If the compensation is to be performed by reference to Shell Marks,
please fulfil data PAM, MM and PFM.
Measures
METER
!
!
!
!
!
!
!
!
!
!
!
!
!
! : Data to be fulfilled by Yard, with respect of the sign + or All Measurements with 3 decimal digits eq. 1.098 m
Shell mark
Fore
Middle Shell
mark
Shell mark
After
Mid Draft P or S
Perpendicular
After
Midship
Draft After
Perpendicular
Fore
Draft Fore
+MM
+PAM
+MP or MS
+PAA
LPP
Page 5 / 9
+PFM
+PFF
Draft After
Draft Fore
+ CA
+ CF
Centerline
Centerline
Mid Draft
Port
Mid Draft
Starboard
+ CP
5.0
+CS
Page 6 / 9
APPENDIX 1
How to measure and calculate Sensor positions for Level Transmitter mounting
Y- Position
The Y Position is calculated from the measured values DAFT and TOTAL TANK LENGTH.(See fig. 1
or 2).
Y- POS = TANK LENGTH - SENSOR DISTANCE FROM AFT BULKHEAD (DAFT)
X- Position
The X Position is calculated from the measured values DPS and TOTAL TANK BREADTH.(See fig. 1
or 2).
X- POS = TANK BREADTH - SENSOR DISTANCE FROM PS BULKHEAD (DPS)
Page 7 / 9
APPENDIX 1
TOTAL BREADTH
TOTAL BREADTH
DPS
TOTAL BREADTH
DPS
DPS
TOTAL LENGTH
TOTAL LENGTH
TOTAL BREADTH
DAFT
TOTAL BREADTH
TOTAL LENGTH
DAFT
DAFT
TOTAL BREADTH
DPS
DPS
DPS
DAFT
Fig. 1
Page 8 / 9
TOTAL LENGTH
DAFT
TOTAL LENGTH
TOTAL LENGTH
DAFT
TOTAL LENGTH
APPENDIX 1
TOTAL BREADTH
DPS
DAFT
TOTAL BREADTH
TOTAL LENGTH
TOTAL LENGTH
TOTAL LENGTH
DPS
DAFT
TOTAL BREADTH
TOTAL BREADTH
DPS
DPS
DAFT
DAFT
DPS
DAFT
TOTAL LENGTH
TOTAL BREADTH
Fig. 2
Page 9 / 9
3-2
Ullage CO1P
Upper temp CO1P
Middle temp. CO1P
Lower temp. CO1P
Inert gas press. CO1P
Ullage 01S
Upper temp. C01S
Middle temp. C01S
Lower temp. C01S
Inert gas press. C01S
Ullage C0 2P
Upper temp. C0 2P
Middle temp. C0 2P
Lower temp. C0 2P
Inert gas press. C0 2P
Ullage C02S
Upper temp. C02S
Middle temp. C02S
Lower temp. C02S
Inert gas press. C02S
Ullage C03P
Upper temp. C03P
Middle temp. C03P
Lower temp. C03P
Inert gas press. C03P
Ullage C03S
Upper temp. C03S
Middle temp. C03S
Lower temp. C03S
Inert gas press. C03S
Ullage C04P
Upper temp. C04P
Middle temp. C04P
Lower temp. C04P
Inert gas press. C04P
Ullage CO4S
Upper temp. CO4S
Middle temp. CO4S
Lower temp. CO4S
Inert gas press. CO4S
Ullage C05P
Upper temp. C05P
Middle temp. C05P
Lower temp. C05P
Inert gas press. C05P
Ullage C05S
Upper temp. C05S
Middle temp. C05S
Lower temp. C05S
Inert gas press. C05S
Ullage C06P
Upper temp. C06P
Middle temp. C06P
Lower temp. C06P
Inert gas press. C06P
Ullage C06S
Upper temp. C06S
Middle temp. C06S
Lower temp. C06S
Inert gas press. C06S
TAG Number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
Type of meas.
Ullage
Temperature
Temperature
Temperature
Abs. pressure
Ullage
Temperature
Temperature
Temperature
Abs. pressure
Ullage
Temperature
Temperature
Temperature
Abs. pressure
Ullage
Temperature
Temperature
Temperature
Abs. pressure
Ullage
Temperature
Temperature
Temperature
Abs. pressure
Ullage
Temperature
Temperature
Temperature
Abs. pressure
Ullage
Temperature
Temperature
Temperature
Abs. pressure
Ullage
Temperature
Temperature
Temperature
Abs. pressure
Ullage
Temperature
Temperature
Temperature
Abs. pressure
Ullage
Temperature
Temperature
Temperature
Abs. pressure
Ullage
Temperature
Temperature
Temperature
Abs. pressure
Ullage
Temperature
Temperature
Temperature
Abs. pressure
Meas. range
0 to 30000
-40 to +120
-40 to +120
-40 to +120
900 to 1300
0 to 30000
-40 to +120
-40 to +120
-40 to +120
900 to 1300
0 to 30000
-40 to +120
-40 to +120
-40 to +120
900 to 1300
0 to 30000
-40 to +120
-40 to +120
-40 to +120
900 to 1300
0 to 30000
-40 to +120
-40 to +120
-40 to +120
900 to 1300
0 to 30000
-40 to +120
-40 to +120
-40 to +120
900 to 1300
0 to 30000
-40 to +120
-40 to +120
-40 to +120
900 to 1300
0 to 30000
-40 to +120
-40 to +120
-40 to +120
900 to 1300
0 to 30000
-40 to +120
-40 to +120
-40 to +120
900 to 1300
0 to 30000
-40 to +120
-40 to +120
-40 to +120
900 to 1300
0 to 30000
-40 to +120
-40 to +120
-40 to +120
900 to 1300
0 to 30000
-40 to +120
-40 to +120
-40 to +120
900 to 1300
Units
mm
C
C
C
mbar
mm
C
C
C
mbar
mm
C
C
C
mbar
mm
C
C
C
mbar
mm
C
C
C
mbar
mm
C
C
C
mbar
mm
C
C
C
mbar
mm
C
C
C
mbar
mm
C
C
C
mbar
mm
C
C
C
mbar
mm
C
C
C
mbar
mm
C
C
C
mbar
Sensor model
TA840
T901-P31A
T901-P31A
T901-P31A
T901-P31A
TA840
T901-P31A
T901-P31A
T901-P31A
T901-P31A
TA840
T901-P31A
T901-P31A
T901-P31A
T901-P31A
TA840
T901-P31A
T901-P31A
T901-P31A
T901-P31A
TA840
T901-P31A
T901-P31A
T901-P31A
T901-P31A
TA840
T901-P31A
T901-P31A
T901-P31A
T901-P31A
TA840
T901-P31A
T901-P31A
T901-P31A
T901-P31A
TA840
T901-P31A
T901-P31A
T901-P31A
T901-P31A
TA840
T901-P31A
T901-P31A
T901-P31A
T901-P31A
TA840
T901-P31A
T901-P31A
T901-P31A
T901-P31A
TA840
T901-P31A
T901-P31A
T901-P31A
T901-P31A
TA840
T901-P31A
T901-P31A
T901-P31A
T901-P31A
Page 1 / 2
Zener Barrier
WIRING LIST
A/D converter
TA840
TA840
TA840
TA840
TA840
TA840
TA840
TA840
TA840
TA840
TA840
TA840
TA840
TA840
TA840
TA840
TA840
TA840
TA840
TA840
TA840
TA840
TA840
TA840
TA840
TA840
TA840
TA840
TA840
TA840
TA840
TA840
TA840
TA840
TA840
TA840
TA840
TA840
TA840
TA840
TA840
TA840
TA840
TA840
TA840
TA840
TA840
TA840
Interface rack Nb
TA840-I safety module rack 1
TA840-I safety module rack 1
TA840-I safety module rack 1
TA840-I safety module rack 1
TA840-I safety module rack 1
TA840-I safety module rack 1
TA840-I safety module rack 1
TA840-I safety module rack 1
TA840-I safety module rack 1
TA840-I safety module rack 1
TA840-I safety module rack 1
TA840-I safety module rack 1
TA840-I safety module rack 1
TA840-I safety module rack 1
TA840-I safety module rack 1
TA840-I safety module rack 1
TA840-I safety module rack 1
TA840-I safety module rack 1
TA840-I safety module rack 1
TA840-I safety module rack 1
TA840-I safety module rack 1
TA840-I safety module rack 1
TA840-I safety module rack 1
TA840-I safety module rack 1
TA840-I safety module rack 1
TA840-I safety module rack 1
TA840-I safety module rack 1
TA840-I safety module rack 1
TA840-I safety module rack 1
TA840-I safety module rack 1
TA840-I safety module rack 1
TA840-I safety module rack 1
TA840-I safety module rack 1
TA840-I safety module rack 1
TA840-I safety module rack 1
TA840-I safety module rack 2
TA840-I safety module rack 2
TA840-I safety module rack 2
TA840-I safety module rack 2
TA840-I safety module rack 2
TA840-I safety module rack 2
TA840-I safety module rack 2
TA840-I safety module rack 2
TA840-I safety module rack 2
TA840-I safety module rack 2
TA840-I safety module rack 2
TA840-I safety module rack 2
TA840-I safety module rack 2
TA840-I safety module rack 2
TA840-I safety module rack 2
TA840-I safety module rack 2
TA840-I safety module rack 2
TA840-I safety module rack 2
TA840-I safety module rack 2
TA840-I safety module rack 2
TA840-I safety module rack 2
TA840-I safety module rack 2
TA840-I safety module rack 2
TA840-I safety module rack 2
TA840-I safety module rack 2
Channel TA 840-I
1
1
1
1
1
2
2
2
2
2
3
3
3
3
3
4
4
4
4
4
5
5
5
5
5
6
6
6
6
6
7
7
7
7
7
8
8
8
8
8
9
9
9
9
9
10
10
10
10
10
11
11
11
11
11
12
12
12
12
12
Modbus address
4
9
10
11
6
4
9
10
11
6
4
9
10
11
6
4
9
10
11
6
4
9
10
11
6
4
9
10
11
6
4
9
10
11
6
4
9
10
11
6
4
9
10
11
6
4
9
10
11
6
4
9
10
11
6
4
9
10
11
6
File : 759197-12.xls
Ref. 759197-12
Rev. 00
Date of issue : 26/06/02
connecting drawing
Terminal - Micatrans
Terminal +
Micatrans
FO DAILY N 1P
DO STORAGE N 1P
DO STORAGE N 1S
DO DAILY TANK
DO DAILY TANK
AFF FF DO SERVICE TK
FWD FF DO SERVICE TANK
FWD EMERG.DG DO TK
IG & HEALTER`S DO DAILY TANK
F.O. N 1 P
F.O. N 1 S
FW STORAGE TK P
FW STORAGE TK S
WB FOREPEAK P
WB FOREPEAK S
WB TK 1P
WB TK 1S
WB TK 2P
WB TK 2S
WB AFT PEAK P
WB AFT PEAK S
FORE DRAFT
AFT DRAFT
TRIM PORT DRAFT
TRIM STBD DRAFT
Atmospheric pressure
Inclinometer TRIM
Inclinometer HEEL
CO1P
CO1S
CO2P
CO2S
CO3P
CO3S
CO4P
CO4S
CO5P
CO5S
CO6P
CO6S
OIL SETTLING TANK
WATER SETTLING TANK
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
TAG Number
61
62
63
64
65
66
67
68
69
70
Type of meas.
On / Off
On / Off
On / Off
level switch
level switch
level switch
level switch
level switch
level switch
level switch
level switch
level switch
level switch
level switch
level switch
level switch
level switch
Abs. pressure
Angle
Angle
level
level
level
level
level
level
level
level
level
level
level
level
level
level
level
level
level
level
level
level
level
level
level
level
level
Ullage
Temperature
Temperature
Temperature
Abs. pressure
Ullage
Temperature
Temperature
Temperature
Abs. pressure
Meas. range
900 to 1100
-10 +10
-10 +10
7693
13473
13473
4548
4548
1250
2465
1955
4548
22883
22883
13450
13450
23934
23934
23652
23652
23652
23652
24036
24036
17261
17261
17261
17261
0 to 30000
-40 to +120
-40 to +120
-40 to +120
900 to 1300
0 to 30000
-40 to +120
-40 to +120
-40 to +120
900 to 1300
Units
mbar
(deg.)
(deg.)
mm WC
mm WC
mm WC
mm WC
mm WC
mm WC
mm WC
mm WC
mm WC
mm WC
mm WC
mm WC
mm WC
mm WC
mm WC
mm WC
mm WC
mm WC
mm WC
mm WC
mm WC
mm WC
mm WC
mm WC
mm WC
mm
C
C
C
mbar
mm
C
C
C
mbar
Sensor model
Free Contact
Free Contact
Free Contact
LIDEC L92 B
LIDEC L92 B
LIDEC L92 B
LIDEC L92 B
LIDEC L92 B
LIDEC L92 B
LIDEC L92 B
LIDEC L92 B
LIDEC L92 B
LIDEC L92 B
LIDEC L92 B
LIDEC L92 B
LIDEC L92 B
LIDEC L92 B
CT701A ATM
INC840
INC840
PL3701
PL3701
PL3701
PL3701
PL3701
PL3701
PL3701
PL3701
PL3701
PL3701
PL3701
PL3702
PL3702
PL3702
PL3702
PL3702
PL3702
PL3702
PL3702
PL3702
PL3702
PL3701
PL3701
PL3701
PL3701
TA840
T901-P31A
T901-P31A
T901-P31A
T901-P31A
TA840
T901-P31A
T901-P31A
T901-P31A
T901-P31A
Page 2 / 2
Zener Barrier
WIRING LIST
X
X
X
X
X
X
X
X
X
X
X
X
X
X
A/D converter
MICATRANS A/D
MICATRANS A/D
MICATRANS A/D
MICATRANS A/D
MICATRANS A/D
MICATRANS A/D
MICATRANS A/D
MICATRANS A/D
MICATRANS A/D
MICATRANS A/D
MICATRANS A/D
MICATRANS A/D
MICATRANS A/D
MICATRANS A/D
MICATRANS A/D
MICATRANS A/D
MICATRANS A/D
MICATRANS A/D
MICATRANS A/D
MICATRANS A/D
MICATRANS A/D
MICATRANS A/D
MICATRANS A/D
MICATRANS A/D
MICATRANS A/D
MICATRANS A/D
MICATRANS A/D
MICATRANS A/D
TA840
TA840
TA840
TA840
TA840
TA840
TA840
TA840
Interface rack Nb
TA840-I safety module rack 1
TA840-I safety module rack 1
TA840-I safety module rack 1
CARLA
CARLA
CARLA
CARLA
CARLA
CARLA
CARLA
CARLA
CARLA
CARLA
CARLA
CARLA
CARLA
CARLA
Channel TA 840-I
42
43
44
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
13
13
13
13
13
14
14
14
14
14
Modbus address
2
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
4
9
10
11
6
4
9
10
11
6
Terminal +
Micatrans
76
79
82
1
4
7
10
13
16
19
22
25
28
31
34
37
40
43
46
49
52
55
58
61
64
67
70
73
Terminal - Micatrans
77
80
83
2
5
8
11
14
17
20
23
26
29
32
35
38
41
44
47
50
53
56
59
62
65
68
71
74
File : 759197-12.xls
Ref. 759197-12
Rev. 00
Date of issue : 26/06/02
connecting drawing
Technical description
Tel. +33.(0)1.49.11.65.75
Fax +33.(0)1.49.11.65.76
Auxitrol - SA au capital de 65 595 700 FRF - R.C.S. Bourges B 602 023 251- Sige Social : 5, alle Charles Path - 18941 Bourges Cedex 9 - France
IMC SYSTEM
Item
Contents
Description
Page
Revision Page
2
2.1
2.2
4
4
5
5
5.1
5.2
5.3
Mechanical installation
TA840 Level Transmitter
TA 840-I Safety Module
T 901-P temperature / pressure sensor
9
9
12
13
6
6.1
6.2
6.3
6.4
Electrical installation
Important remarks
TA840 Level Transmitter
TA 840-I Safety Module
T 901-P temperature / pressure transmitter
14
14
14
18
20
Drawings in appendix
21
Tel. +33.(0)1.49.11.65.75
Fax +33.(0)1.49.11.65.76
Auxitrol - SA au capital de 65 595 700 FRF - R.C.S. Bourges B 602 023 251- Sige Social : 5, alle Charles Path - 18941 Bourges Cedex 9 - France
REVISION PAGE
Revision
Date of issue
REV01
20/05/98
AUTHOR
Modification
Location
all
APPROBATOR
DIRECTION
Tel. +33.(0)1.49.11.65.75
Fax +33.(0)1.49.11.65.76
Auxitrol - SA au capital de 65 595 700 FRF - R.C.S. Bourges B 602 023 251- Sige Social : 5, alle Charles Path - 18941 Bourges Cedex 9 - France
2.1
ULLAGE
MESURE
CARGO
Tel. +33.(0)1.49.11.65.75
Fax +33.(0)1.49.11.65.76
Auxitrol - SA au capital de 65 595 700 FRF - R.C.S. Bourges B 602 023 251- Sige Social : 5, alle Charles Path - 18941 Bourges Cedex 9 - France
2.2
Functional description
The TA840 radar has a FLAT-T technology antenna covered and protected by PTFE radome
used to protect antenna against tanks atmosphere. The electronics is completely sealed in
its stainless steel AISI 316L housing. Due to this compact design, all parts in contact with
liquid or atmosphere of cargo tank are PTFE or 316L.
Antenna is included in sealed part of stainless steel housing. To access to terminal box,
remove screws and cover.
Tel. +33.(0)1.49.11.65.75
Fax +33.(0)1.49.11.65.76
Auxitrol - SA au capital de 65 595 700 FRF - R.C.S. Bourges B 602 023 251- Sige Social : 5, alle Charles Path - 18941 Bourges Cedex 9 - France
Due to its location in hazardous area on deck, TA840 radar meets EN 50014 and EN 50020
Intrinsic Safety (IS) rules. The power supplies and digital link from each transmitter are
protected by an individual "safety block" located in TA840-I Safety Module installed in cargo
control room.
The classification of TA 840 radar is EEx ia IIB T4 for installation in Zone 0.
The certificate of conformity has been issued from LCIE laboratory with following reference:
LCIE 95.D6119X
The TA 840 radar must only be connected to TA 840-I safety module and T901-P
temperature pressure transmitter.
See paragraph Electrical installation for cables characteristic which can be used.
Tel. +33.(0)1.49.11.65.75
Fax +33.(0)1.49.11.65.76
Auxitrol - SA au capital de 65 595 700 FRF - R.C.S. Bourges B 602 023 251- Sige Social : 5, alle Charles Path - 18941 Bourges Cedex 9 - France
Each TA840 radar is connected to an individual safety block specially designed to power
transmitter and link RS485 digital bus, according to EN50020 intrinsic safety rules.
CPU board
Main supply switch
Safety blocks
Status LED
All safety blocks are plugged into TA840-I safety module based on a 3U 19 standard rack,
with up to 8 safety blocks per rack. The next safety blocks will be inserted into as many racks
as needed (modulo 8 blocks per rack).
In front of each safety block, four-status LED show state of both power supply lines and data
transmission between TA840 radar and TA840-I Safety Module.
In addition, a RS232 digital link, located in front of each safety block, allows direct access to
TA840 concerned, particularly during commissioning.
The continuously polling of all TA840 radar is performed by CPU (Control Processing Unit) board
integrated in master rack, which then transmits received data to cargo monitoring system using a
digital link (RS232 or RS485).
Another digital link, in front of processing board, is used for system checking and/or as a low-grade
supervisor output in case of main supervisors failure.
Tel. +33.(0)1.49.11.65.75
Fax +33.(0)1.49.11.65.76
Auxitrol - SA au capital de 65 595 700 FRF - R.C.S. Bourges B 602 023 251- Sige Social : 5, alle Charles Path - 18941 Bourges Cedex 9 - France
Electrical connection
with cable flexible tube
T901-P
Process flange
2 150 #
Flat gasket
Washer
4 nuts M16
Hole for pressure sensor
RTD sensor 100 ohm at
0C (IEC 751 standard)
Tel. +33.(0)1.49.11.65.75
Fax +33.(0)1.49.11.65.76
Auxitrol - SA au capital de 65 595 700 FRF - R.C.S. Bourges B 602 023 251- Sige Social : 5, alle Charles Path - 18941 Bourges Cedex 9 - France
MECHANICAL INSTALLATION
5.1
CL
AF
30
Systems & Sensors Division
Tel. +33.(0)1.49.11.65.75
Fax +33.(0)1.49.11.65.76
Auxitrol - SA au capital de 65 595 700 FRF - R.C.S. Bourges B 602 023 251- Sige Social : 5, alle Charles Path - 18941 Bourges Cedex 9 - France
Be careful that after final installation the surface of the fixing flange must be horizontal
within 0.5 degrees for a ship at even keel.
To protect packing-glands and flexible tubes against powerful jets of sea water, cables
protecting tubes must be installed on AFT side of socket and 30 to centreline.
It is also possible to make junction between flexible tube and cable protecting tube with
threaded flange as hereafter indicated.
Socket FOR TA840 Radar with threaded
flange for flexible tube connection
1 or female thread (ISO 7)
The TA 840 radar is delivered in an individual box with an antenna protection plate to prevent
any damage on radome before final installation.
Plastic protection
Tel. +33.(0)1.49.11.65.75
Fax +33.(0)1.49.11.65.76
Auxitrol - SA au capital de 65 595 700 FRF - R.C.S. Bourges B 602 023 251- Sige Social : 5, alle Charles Path - 18941 Bourges Cedex 9 - France
Be careful to avoid any shocks to antenna surface, and remove antenna protection plate just
before installing radar on socket.
Before to install TA 840 radar, clean flange face, install gasket (drawing M13130 for Nitril
gasket) and after removing antenna protection place radar on the flange. (Be careful about
position of two fixing hole for pivot).
(For chemical applications, we propose to use Gore-Tex gasket.)
Fix pivot on socket and on radar with braided earth conductor on left side of pivot as
indicated on the following picture.
The TA 840 radar is fixed on socket with 6 bolts M20 x 100 and a flat gasket with a tightening
torque from 60 to 70 mN.
Tel. +33.(0)1.49.11.65.75
Fax +33.(0)1.49.11.65.76
Auxitrol - SA au capital de 65 595 700 FRF - R.C.S. Bourges B 602 023 251- Sige Social : 5, alle Charles Path - 18941 Bourges Cedex 9 - France
19 cabinet for
TA840-I Safety Module
Forced air module
Master TA840-I Safety Module
Slave TA840-I Safety Module
1U = 44 mm
Tel. +33.(0)1.49.11.65.75
Fax +33.(0)1.49.11.65.76
Auxitrol - SA au capital de 65 595 700 FRF - R.C.S. Bourges B 602 023 251- Sige Social : 5, alle Charles Path - 18941 Bourges Cedex 9 - France
5.2
T901-P
Flat gasket
Upper deck
Aft bulkhead
Tel. +33.(0)1.49.11.65.75
Fax +33.(0)1.49.11.65.76
Auxitrol - SA au capital de 65 595 700 FRF - R.C.S. Bourges B 602 023 251- Sige Social : 5, alle Charles Path - 18941 Bourges Cedex 9 - France
ELECTRICAL INSTALLATION
6.1
IMPORTANT REMARKS
The TA 840 radar and T901-P temperature / pressure sensor are installed on deck in a
hazardous area. The IMC System is approved EN 50014, EN 50020 and EN 50039
according to European standards for use in Intrinsic Safety (IS). The certificate of conformity
of complete TA-840 system has been issued from LCIE laboratory with reference:
6.2
To T901-P
Tel. +33.(0)1.49.11.65.75
Fax +33.(0)1.49.11.65.76
Auxitrol - SA au capital de 65 595 700 FRF - R.C.S. Bourges B 602 023 251- Sige Social : 5, alle Charles Path - 18941 Bourges Cedex 9 - France
Tel. +33.(0)1.49.11.65.75
Fax +33.(0)1.49.11.65.76
Auxitrol - SA au capital de 65 595 700 FRF - R.C.S. Bourges B 602 023 251- Sige Social : 5, alle Charles Path - 18941 Bourges Cedex 9 - France
Cables arrive to TA 840 connection box through a flexible protecting tube made in inside part
of special rubber, and outside with stainless steel armouring . The overall length is 700 mm.
On one side a threaded connection for fixing to cable protecting tube, and other side is union
coupling.
Electrical connection to TA 840 terminal procedure
On top of radar, remove 9 screws M6 to open connection box and access to terminal junction
(hexagonal head screws 10 mm).
Remark: For connection of separate T901P pressure sensor located on TA840 body socket,
AUXITROL provides a special flexible hose, with double packing glands: one for
TA840 Radar side, one for T901P pressure sensor side.
In that case we recommend to connect it first on centre BV2 following items b) then d) to e)
of general procedure for each TA840 Radar and T901P sides
General procedure:
a) Introduce the middle position electric cable (BV2 to separate pressure sensor) into protecting tube.
b) Introduce electrical cable in flexible tube.
c) Screw flexible tube on metallic connection (3/4"male conic BSPT) to cable protection tube.
d) Add item (9), (8) with (7), (5), and (4).
e) Introduce cable in packing-gland body sealed on TA 840 housing.
f) Cut and strip cable to make connection to terminal.
g) Screw gland nut item (6) to compress sealing ring.
h) Screw and block counter nut (7).
i) Screw locking nut (10) to gland nut (8) by using 2 flat wrenches.
j) Then install 2 cables on each side in same order:
-1 cable to T901-P temperature pressure sensor through BV3 packing gland.
-1 cable to TA 840-I safety module through other BV2 packing gland.
K)
To close terminal box, be careful about sealing O-ring which must be in right position in groove, if
necessary with finger put again some silicone grease on it. Place cover in good position and screw 9
hexagonal head screws M6.
Tel. +33.(0)1.49.11.65.75
Fax +33.(0)1.49.11.65.76
Auxitrol - SA au capital de 65 595 700 FRF - R.C.S. Bourges B 602 023 251- Sige Social : 5, alle Charles Path - 18941 Bourges Cedex 9 - France
TA840Radar
Radar terminal
T A 840
terminal box
Radar
terminal
T ATA840
840 Radar,
wiring
diagram
Tel. +33.(0)1.49.11.65.75
Fax +33.(0)1.49.11.65.76
Auxitrol - SA au capital de 65 595 700 FRF - R.C.S. Bourges B 602 023 251- Sige Social : 5, alle Charles Path - 18941 Bourges Cedex 9 - France
6.3
TA 840 radar input terminal must be connected only to TA 840-I safety module and T901-P
temperature / pressure sensor.
L, L/R and C characteristics of connecting cable between TA 840 radar and TA 840-I safety
module must not exceed any of following values:
L 0,1 ;
L/R 24 /;
/ C 0,4 F
Main supply 220 or 110 Vac
Tel. +33.(0)1.49.11.65.75
Fax +33.(0)1.49.11.65.76
Auxitrol - SA au capital de 65 595 700 FRF - R.C.S. Bourges B 602 023 251- Sige Social : 5, alle Charles Path - 18941 Bourges Cedex 9 - France
Tel. +33.(0)1.49.11.65.75
Fax +33.(0)1.49.11.65.76
Auxitrol - SA au capital de 65 595 700 FRF - R.C.S. Bourges B 602 023 251- Sige Social : 5, alle Charles Path - 18941 Bourges Cedex 9 - France
The connections between MASTER TA 840-I Safety Module and SLAVE TA840-I Safety
Modules with flat cables are AUXITROL supply.
INTERCONNECTION
BETWEEN RACKS
TA840 -I SAFETY MODULE
INTERCONNECTION
BETWEEN RACKS
IN
6.4
OUT
Tel. +33.(0)1.49.11.65.75
Fax +33.(0)1.49.11.65.76
Auxitrol - SA au capital de 65 595 700 FRF - R.C.S. Bourges B 602 023 251- Sige Social : 5, alle Charles Path - 18941 Bourges Cedex 9 - France
DT2395E
REV 05
Page 1/22
INTERFACE OF
THE LEVEL MEASUREMENT SYSTEM
ON BOARD VESSELS
TA840-I
SAFETY MODULE
COMMUNICATION PROTOCOL
Auxitrol - SA au capital de 25 000 000 FRF - R.C.S. Bourges B 602 023 251 - Siret 602 023 251 00021 - APE 332B - T.V.A. FR 90 602 023 251
Direction Commerciale : 168 Bureaux de la Colline - 92213 Saint Cloud Cedex - France - Tl. : +33 (0) 1 49 11 65 75 - Fax : +33 (0) 1 49 11 65
76
DT2395E
REV 05
Page 2/22
REVISION
Revision
Date
Paragraphs
Modifications
00
30/06/95
01
30/09/96
2 and 3
Updating
02
18/12/96
Updating
03
10/01/97
04
06/08/97
05
25/01/01
3.3
AUTHOR
Original document
Minor corrections
Minor corrections
Updating
SIGNATURE
DATE
SIGNATURE
DATE
L. MAUDUIT
APPROVED BY
T. LEPREVOST
DT2395E
REV 05
Page 3/22
CONTENTS
1)
GENERAL PRESENTATION
2)
HARDWARE CONFIGURATION
3)
2.1)
2.2)
COMMUNICATION PROTOCOL
3.1)
3.2)
3.3)
3.4)
3.5)
3.6)
3.7)
DT2395E
REV 05
Page 4/22
1-
GENERAL PRESENTATION
This document presents the communication protocol used between the TA840-I safety
module of the AUXITROL - I.M.C. System cargo measuring system and, on the one hand, the
main monitoring system, and, on the other hand, the System P.C.
CPU board
TA840-I safety module
(master rack)
System P.C.
Individual
Indicators
The communication between the TA840-I safety module's master rack and the main
monitoring system is by means of a serial link, and according to a master/slave MODBUS type
protocol.
Similarly, the communication between the TA840-I safety modules master rack and the
System P.C. is also by means of a serial link, and according to the same master/slave
MODBUS type protocol.
DT2395E
REV 05
Page 5/22
Furthermore, the TA840-I safety module communicates with the TA840 Radar transmitters
which are connected to it, and periodically refreshes all the information from the measurements
on the cargo tanks. It can be connected to a 4-20mA acquisition unit (AUXITROL's
MICATRANS A/D type) making possible to receive data from pressure, temperature,
inclinometers, or any 4-20mA transmitters.
2-
HARDWARE CONFIGURATION
2.1)
This link uses either an RS232 serial port (Sub-D 9 pins) or an RS485 type field bus
(2-wire).
These two connectors are located on the rear of the TA840-I safety module's master
rack.
Selection of the RS232 or RS485 link is done by switching two jumpers located on
the master racks CPU board:
RS232 mode (cable lenght 10 m)
lll
lll
CPU board
(components side view)
DT2395E
REV 05
Page 6/22
2.2)
3-
COMMUNICATION PROTOCOL
3.1) General structure of the frames:
The dialogue frames are identical for the two links with the main monitoring system and
the System P.C.
Exchanges are made at the initiative of the monitoring system or of the System P.C.
which operate in master mode, while the TA840-I safety module operates in slave mode.
The monitoring system or the System P.C. send a question to the TA840-I safety
module which answers with the data from the interrogated slave.
The general structure of a question frame is as follows:
DT2395E
REV 05
Page 7/22
Question:
Slave n
Function code
Information
(1 byte)
(1 byte)
(n bytes)
: reading of n bits
: reading of n words
: writing of 1 bit
: writing of 1 word
: writing of n bits
: writing of n words
Control word
CRC 16
(2 bytes)
Function code
Information
(1 byte)
(1 byte)
(n bytes)
Control word
CRC 16
(2 bytes)
Control of messages:
The control word CRC 16 is calculated by the sender of a message. On receipt of the
latter, the receiver recalculates the CRC 16 of the frame received and does not answer the
question if it finds the CRC 16 word different.
If the control word CRC 16 is acceptable, but the receiver does not recognise the
question (incorrect address or data), it sends back the code of the function with the most
significant bit (msb) (bit 7) at 1, followed by a byte defining the type of error.
DT2395E
REV 05
Page 8/22
Slave n
(1 byte)
Function code
(with bit7 at 1)
(1 byte)
Error code
(1 byte)
Control word
CRC 16
(2 bytes)
DT2395E
REV 05
Page 9/22
3.2)
Number of bits
(2 bytes)
Control word
CRC 16
(2 bytes)
Answer:
Slave n Function code Number of 1st byte
(1 byte)
= 1 or 2
bytes read
read
(1 byte)
(1 byte)
(1 byte)
last byte
read
(1 byte)
Control word
CRC 16
(2 bytes)
The first bit transmitted is the bit b0, beyond the last bit bn the bits not used are set at 0.
Number of words
127 maximum
(2 bytes)
Control word
CRC 16
(2 bytes)
Answer:
Slave n Function code Number of 1st word
(1 byte)
= 3 or 4
bytes read
read
(1 byte)
(1 byte) (2 bytes)
last word
read
(2 bytes)
Control word
CRC 16
(2 bytes)
Function
code = 5
(1 byte)
Value of the
bit
(1 byte)
0
(1 byte)
Control word
CRC 16
(2 bytes)
The value of the bit is 00 (hex) for the writing of a bit at 0 , and FF (hex) for the writing ofa
bit at 1 .
Answer:
The answer frame is identical to the question frame.
DT2395E
REV 05
Page 10/22
Function
code = 6
(1 byte)
Control word
CRC 16
(2 bytes)
Answer:
The answer frame is identical to the question frame.
Function
code = 15
(1 byte)
addr. of the
1st bit
msb, lsb
(2 bytes)
number number
of bits of bytes
(2 bytes) (1 byte)
value of
the bits
(n bytes)
Control word
CRC 16
(2 bytes)
Answer:
Slave n Function code =
(1 byte)
15
(1 byte)
number of bits
(2 bytes)
Control word
CRC 16
(2 bytes)
Function
code = 16
(1 byte)
addr. of the
1st word
msb, lsb
(2 bytes)
number
of words
(2 bytes)
number
of bytes
(1 byte)
value of
the 1st
word
(2 bytes)
Control word
CRC 16
(2 bytes)
Answer:
Slave n
(1 byte)
Function code =
16
(1 byte)
number of words
(2 bytes)
Control word
CRC 16
(2 bytes)
DT2395E
REV 05
Page 11/22
Type of data
word
word
word
word
signed word
signed word
word
word
signed word
signed word
signed word
word
word
signed word
signed word
signed word
signed word
signed word
word
word
word
word
word
word
bit
bit
bit
bit
bit
bit
bit
Definition
reserved
reserved
ullage (tenths of mm: 0 to 9)
ullage (in mm: 0 to 32000)
mean temperature (in tenths of C: -400 to +1200)
I.G. pressure (in tenths of mbar: -700 to +3500)
name1 of tank (2 ASCII characters)
name2 of tank (2 ASCII characters)
temperature n 1 (in tenths of C: -400 to +1200)
temperature n 2 (in tenths of C: -400 to +1200)
temperature n 3 (in tenths of C: -400 to +1200)
reserved
max. height (in mm: 0 to 32000)
offset between the radar and the manual sounding reference (in mm)
reserved
reserved
min. pressure of the I.G. transducer (in tenths of mbar)
max. pressure of the I.G. transducer (in tenths of mbar)
reserved
ullage of temperature sensor n 1 (at top of tank, in mm)
ullage of temperature sensor n 2 (in middle of tank, in mm)
ullage of temperature sensor n 3 (at bottom of tank, in mm)
reserved
type of slave
temperature n 1 validated (bit = 1)
temperature n 2 validated (bit = 1)
temperature n 3 validated (bit = 1)
I.G. pressure validated (bit = 1)
offset validated (bit = 1)
reserved
TA840 radar validated (bit = 1)
Note: All those data are accessible in reading by both the System P.C. and monitoring
system links, (but only in writing by the System P.C. link). The bit of address @63 is
also accessible in writing by the monitoring system.
DT2395E
REV 05
Page 12/22
DT2395E
REV 05
Page 13/22
DT2395E
REV 05
Page 14/22
0
1
2
3
4
5
6
7
8
TA840 radar
relative pressure transmitter
FORE draft relative pressure transmitter
AFT draft relative pressure transmitter
PORT draft relative pressure transmitter
STARBOARD draft relative pressure transmitter
absolute pressure transmitter
temperature transmitter
inclinometer
DT2395E
REV 05
Page 15/22
Type of data
word
word
word
word
word
word
word
word
word
word
word
word
word
word
signed word
signed word
word
word
bit
bit
bit
Definition
Revision of the software (e.g.: 102 = revision 1.02)
year of revision (e.g.: 96)
month of revision (e.g.: 09)
date of revision (e.g.: 23)
current year
current month
current date
current day (e.g.: 1 = Sunday)
current hours
current minutes
current seconds
monitoring system links rate (1200, 2400, 4800, 9600 or 19200)
system P.C. links mode
system P.C. links rate (1200, 2400, 4800, 9600 or 19200)
TRIM height (in cm)
HEEL angle (in hundredths of degree)
length between perpendiculars (in cm)
reserved
configuration of the TA840 radar in progress (bit on 1)
system fault on the TA840-I safety module (bit on 1)
reserved
Note: All those data are accessible in reading and writing by the System P.C. link, but only
in reading by the monitoring system link.
DT2395E
REV 05
Page 16/22
Revision and date of the TA840-I safety modules software (@1, @2, @3 and @4):
Those values correspond to the version and date of the software installed in the TA840-I
racks CPU board.
TA840-I safety modules internal clock (@5, @6, @7, @8, @9, @10 and @11):
Those addresses make it possible to read (or to set) the current date and time of the
internal clock of the TA840-I racks CPU board.
It should be remembered that this clock is also used to date the events recorded during
operation ( data logging ).
Baud rate with the main monitoring system (@12):
This address makes it possible to read (or to set) the baud rate with the main monitoring
system.
The value can be either 1200, 2400, 4800, 9600 or 19200 bauds.
Function mode of the system PC link (@ 13):
This address enables to set the System PC links function:
A 0 value means a Monitoring system type link
A 1 value means a Portable Control Device type link
A 2 value means an individual indicator type link
Baud rate with the system P.C. link (@ 14):
This address makes it possible to read (or to set) the baud rate with the System
P.C. link.
The value can be either 1200, 2400, 4800, 9600 or 19200 bauds.
DT2395E
REV 05
Page 17/22
Trim (@ 15)
This value corresponds to the Trim (in cm) of the vessel.
It represents the difference between the AFT draft minus the FORE draft. This value is
calculated at the perpendiculars .
Positive TRIM
If one of the drafts value is not correct, the TRIM will be set to 6000 cm.
Heel (@ 16)
This value corresponds to the Heel angle (in hundredths of degree) of the vessel.
It represents the difference between starboard draft minus the port draft.
STARBOARD
Positive HEEL
If one of the drafts value is not correct, the HEEL will be set to 9000 hundredths of
degree (90.00).
Length LPP (@ 17)
This value corresponds to the length between perpendiculars AFT and FORE (in cm).
Configuration of radar in progress (@451):
This bit, when it is set at 1, indicates to the monitoring system that one of the TA840
radars is being configured, and therefore is momentarily no longer accessible to the monitoring
system.
System fault detected on the TA840-I safety module (@452):
This bit, when it is set at 1, indicates to the monitoring system that a system fault has
been detected on the TA840-I safety module.
DT2395E
REV 05
Page 18/22
Type of data
word
signed word
word
word
signed word
signed word
word
word
word
word
word
word
bit
bit
Definition
specific gravity of the liquid (kg per m3)
pressure in mbar
level (innage, in mm: 0 to 32000)
4-20 mA current signal (in hundredths of mA)
min. pressure in mbar
max. pressure in mbar
tank name1 (2 characters ASCII)
tank name2 (2 characters ASCII)
calibration maximum height (in mm)
calibration minimum height (in mm)
reserved
type of slave
reserved
transmitter validation (bit = 1)
Note: All those data are accessible in reading by both the System P.C. and the monitoring
system links, (but only in writing by the system link). The specific gravity of the liquid
(address @1) and the transmitter validation (address @63) are also accessible in
writing by the monitoring system.
Specific gravity of the liquid (@1):
It is a value in kg per m3 which enables to calculate the innage of the liquid.
Pressure (@2):
It is a signed value in mbar, calculated from the measured 4-20mA current.
Level (@3):
It is a value in mm, calculated from the measured pressure and the liquids specific
gravity located at the address @1.
If the value is wrong, the transmitted value will be 60000 mm.
4 -20 mA Current (@4):
It is the measured current value (in hundredths of mA).
DT2395E
REV 05
Page 19/22
0
1
2
3
4
5
6
7
8
TA840 radar
relative pressure transmitter
FORE draft relative pressure transmitter
AFT draft relative pressure transmitter
PORT draft relative pressure transmitter
STARBOARD draft relative pressure transmitter
absolute pressure transmitter
temperature transmitter
inclinometer
DT2395E
REV 05
Page 20/22
Type of data
word
signed word
word
signed word
signed word
word
word
word
word
bit
bit
Definition
reserved
temperature (in tenths of C)
4-20 mA current signal (in hundredths of mA)
min. temperature (in tenths of C)
max. temperature (in tenths of C)
tank name1 (2 ASCII characters)
tank name2 (2 ASCII characters)
reserved
type of slave
reserved
transmitter validation
Note: All those data are accessible in reading by both the System P.C. and the monitoring
system links, (but only in writing by the system P.C. link). The transmitter validation
(address @63) is also accessible in writing by the monitoring system.
Temperature (@3):
It is a value in tenths of Celsius degree.
If the value is wrong, the transmitted value is -2000.
4-20 mA Current (@4):
It is the measured current value (in hundredths of mA).
Temperature min. (@5):
It is the temperature transmitter calibrations value in tenths of Celsius degree at 4mA
Temperature max. (@6):
It is the temperature transmitter calibrations value in tenths of Celsius degree at 20mA
Tank name (@7 and @8):
The tank name is coded by 4 ASCII char. into address @7 and @8.
E.g.: tank name 3COT is coded: (@7) HEX = 3343 and (@8) HEX = 4F54
DT2395E
REV 05
Page 21/22
0
1
2
3
4
5
6
7
8
TA840 radar
relative pressure transmitter
FORE draft relative pressure transmitter
AFT draft relative pressure transmitter
PORT draft relative pressure transmitter
STARBOARD draft relative pressure transmitter
absolute pressure transmitter
temperature transmitter
inclinometer
Type of data
word
signed word
word
signed word
signed word
word
word
word
word
bit
bit
Definition
reserved
angle (in hundredths of degree)
4-20 mA current (in hundredths of mA)
min. angle (in hundredths of degree)
max. angle (in hundredths of degree)
tag1 (2 ASCII characters)
tag2 (2 ASCII characters)
reserved
type of slave
reserved
validation of the transmitter (bit = 1)
Note: All those data are accessible in reading by the System P.C. and the monitoring
system links, (but only in writing by the system link). The bit of address @63 is also
accessible in writing by the monitoring system.
DT2395E
REV 05
Page 22/22
Angle (@3):
It is a value in hundredths of degree.
If the value is wrong, the transmitted value is 9000 hundredths of degree.
4-20 mA Current (@4):
It is the measured current value in hundredths of mA.
Min Angle. (@5):
It is the inclinometer calibrations value in hundredths of degree at 4mA
Max. Angle (@6):
It is the inclinometer calibrations value in hundredths of degree at 20mA
Tag (@7 and @8):
The tag is coded by 4 ASCII char. into address @7 and @8.
E.g.: tag TRIM is coded: (@7) HEX = 5452 and (@8) HEX = 494D
Type of Slave (@39):
This value defines the type of slave currently connected.
Value:
0
1
2
3
4
5
6
7
8
TA840 radar
relative pressure transmitter
FORE draft relative pressure transmitter
AFT draft relative pressure transmitter
PORT draft relative pressure transmitter
STARBOARD draft relative pressure transmitter
absolute pressure transmitter
temperature transmitter
inclinometer
CB322533A REV 01
Page 1/7
All right reserved
CONFIGURATIONS
INSTALLATION - ADJUSTMENT
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
CB322533A REV 01
Page 2/7
All right reserved
CONTENT
1) CONFIGURATIONS:
2) TECHNICAL DATA:
3) WIRING CONNECTIONS:
4) ON SITE ADJUSTMENT:
HT TYPE
HORIZONTAL MOUNTING
HH TYPE
HORIZONTAL MOUNTING
VT TYPE
UPRIGHT MOUNTING
VH TYPE
UPRIGHT MOUNTING
VT TYPE
UPRIGHT MOUNTING
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
CB322533A REV 01
Page 3/7
All right reserved
1) CONFIGURATIONS :
TYPES: (see appended drawings)
HT
HORIZONTAL mounting with one inclinometer along the TRIM direction (fore and aft)
HH
HORIZONTAL mounting with one inclinometer along the HEEL direction (athwart ships)
HHT HORIZONTAL mounting with one inclinometer along the TRIM and HEEL directions
VT
VERTICAL mounting with one inclinometer along the TRIM direction (fore and aft)
VH
VERTICAL mounting with one inclinometer along the HEEL direction
VHT VERTICAL mounting with one inclinometer along the TRIM and HEEL directions
The instrument is to be wired prior to mounting with a max. 10mm, min. 5 mm OD shielded cable, with
4 wires of 1.5mm max. sectional area, see wiring diagram on page 2.
The instrument is to be secured so as to bear against the reference planes provided.
2) TECHNICAL DATA:
Supply voltage:
Output parameters
Output:
Zero point (typical
value)
Resolution
Cross axis sensitivity
8 up to 30VDC
4-20mA range:+/-10
12mA
0.01
Dynamic performance
Time constant
0.3s
Maximum ratings
Operating temperature
Storage temperature
- 40C up to + 85C
- 45C up to + 90C
Supply electrical
connection:
1%
3) WIRING CONNECTIONS:
1. Strip the cable along a length of 150mm,
thread it through the cable gland and
under the terminal block
2. Tighten the cable gland
3. Get the wires around the terminal block
and connect:
- HEEL sensor terminals 1 and 2
- TRIM sensor terminals 4 and 5
4. Cable grounding is to be done on the
acquisition side
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
CB322533A REV 01
Page 4/7
All right reserved
4) ON SITE ADJUSTMENT:
Each instrument is factory-preset. The sensors are positioned by
hand so as to read 12mA (to the nearest value), and are secured in
place.
Measure the ships TRIM and HEEL.
Compensate using the offset correction (if greater than 2, reposition
the sensor).
HORIZONTAL positioning
Strength = 12mA
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
CB322533A REV 01
Page 5/7
All right reserved
Reference planes on
board ship
Reference surfaces of
the instrument
Reference planes on
board ship
Reference surfaces
of the instrument
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
CB322533A REV 01
Page 6/7
All right reserved
Reference planes on
board ship
Reference surfaces of
the instrument
Reference planes on
board ship
Reference surfaces of
the instrument
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
CB322533A REV 01
Page 7/7
All right reserved
Reference planes
on board ship
Reference surfaces
of the instrument
Reference planes on
board ship
Reference surfaces
of the instrument
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
0
O
I
CB322514~E
REV04
page 1 / 10
CB322514~E
REV04
page 2 / 10
CONTENTS
1. Purpose
2. General description
2.1.
Functional description
2.2.
Users instructions
2.3.
2.4.
Electrical connections
2.5.
Mechanical installation
3. Technical characteristics
CB322514~E
REV04
page 3 / 10
1. Purpose
This document presents the MICATRANS A/D Analog to Digital Interface.
2. General description
2.1. Functional Description
The main purpose of the MICATRANS A/D Interface is to scan continuously the
4-20 mA transmitters to which it is connected, to digitize the 4-20 mA analog signal,
and to transmit those data to either a PC based MICAD monitoring system or a
TA 840-I Safety Module.
The number of 4-20 mA channels available on each MICATRANS A/D Interface is up
to:
16, 32 or 48
In case of more than 48 inputs, several MICATRANS A/D Interfaces can be put in
parallel, using a RS485 digital link (see 2.3.2.).
It includes a 24 VDC power source module in order to supply directly the 4-20 mA
transmitters. In case of 4-20 mA transmitter connected through zener barrier, the
0 VDC of the power supply shall be earthed using a strap at the rear of the rack.
An external power supply can also be connected to the MICATRANS A/D Interface,
instead of using the internal one.
In front of the MICATRANS A/D Interface, a LCD display and a numeric key pad
allow the reading of a selected 4-20 mA analog input, directly in percentage or in
mA .
CB322514~E
REV04
page 4 / 10
release
When the MICATRANS A/D Interface is switched on, the following data are
displayed:
then,
Esterline AUXITROL
Esterline AUXITROL
MICATRANS A/D
MICATRANS A/D
Ver 2.2
15/01/98
Date
of
release
CHANNEL N1 xx.xx mA
9600 bds - chan :001-048
baud rate
1st channel
last channel
using the numeric key pad 0 ... 9 , and confirm by pressing the # key.
In case of several MICATRANS A/D Interfaces in parallel, the first interface will have
the channel numbers between 1 to 48, the second interface will have the channel
numbers between 49 to 96, the third interface will have the channel numbers
between 97 to 144, and so on...
The channel number 1 (or 49 , or 97 , or...) corresponds to the transmitter
connected to the terminals 1 and 2.
The channel number 2 (or 50 or 98 , or ...) corresponds to the transmitter
connected to the terminals 4 and 5.
The channel number 48 (or 96 , or 144 , or...) corresponds to the
transmitter connected to the terminals 142 and 143.
To change the displayed value from percentage to mA - and reverse -, press
directly the key # .
As soon as the 4-20 mA analog signal becomes lower than 3.3 mA and greater than
21 mA, the displayed value will be respectively:
Esterline AUXITROL
MICATRANS A/D
CHANNEL N1 xx.xx mA
- -.- - mA (or - - -.- %) if < 3.3 mA
++.++ mA (or +++.+ %) if > 21 mA
2.3. Typical Wiring Diagram
CB322514~E
REV04
page 5 / 10
PC based MICAD
monitoring system
MICAD
+
Zener barriers
CT701
up to 48
4-20 mA analog inputs
100-127/200-240 VAC,
50-60 Hz Power Supply
3
6
0
O
I
LCD Display
Power Switch
CB322514~E
REV04
page 6 / 10
CT701
PC based MICAD
monitoring system
CT701
+
CT800
MICAD
CT800
zener
barriers
zener
barriers
1 to 48
4-20 mA analog inputs
49 to 96
4-20 mA analog inputs
up to 5
MICATRANS
A/D Interface
0
O
I
O
I
LCD Display
Power Switch
100-127/200-240 VAC,
50-60 Hz Power Supply
LCD Display
Power Switch
CB322514~E
REV04
page 7 / 10
4-20 mA
Transmitter n2
RS485 link
+
+
-
142
143
144
RS485A
RS485B
CB322514~E
REV04
page 8 / 10
2.4.2. Transmitters connected to the MICATRANS A/D Interface through MTL 706 zener barriers:
4-20 mA
Transmitter n1
Hazardous area
MTL706
+
+
+
-
1
2
3
4
5
6
7
8
9
Safe area
4
4-20 mA
Transmitter n2
MTL706
+24V
0V
In this case, the input load on each current loop using a zener barrier is 250 .
CB322514~E
REV04
page 9 / 10
RS232
digital output
Pin number
2
3
4
7
Function
Tx
Rx
RTS
Ground
Input/Output
output
input
output
-
Nota: The RTS output (pin 4) is needed by some of the RS232/RS485 converter (if external
converter connected) which is used for the communication with a TA840-I Safety Module.
2.4.5. Power supply input:
2.5.
PH
N
Mechanical Installation
The MICATRANS A/D Interface can be installed directly in a standard 19 cubicle. It
can also be installed in a panel, the cut out dimensions are : 448 x 134 mm and it uses
4 M6 x 16 screws for the fixation.
CB322514~E
REV04
page 10 / 10
3. Technical Characteristics
Presentation:
134 +
Power supply:
1
1
mm x 448 + mm
0
0
Scanning rate:
...
keys
Weight:
5 kg
MT 5082-E REV. 00
30.11.2000
All rights reserved
CRI 840
Page 1/8
CRI 840
BACK UP DISPLAY
Technical manual
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
MT 5082-E REV. 00
30.11.2000
All rights reserved
CRI 840
Page 2/8
CONTENT
1. PURPOSE ..................................................................................... 3
2. GENERAL DESCRIPTION ............................................................ 3
2.1. FUNCTIONAL DESCRIPTION ............................................................. 3
2.2. USERS INSTRUCTIONS ................................................................... 3
3. TECHNICAL CHARACTERISTICS................................................ 7
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
MT 5082-E REV. 00
30.11.2000
All rights reserved
CRI 840
Page 3/8
1. Purpose
This document presents the use of CRI 840 Back-up display, specially designed to
display all data related to Cargo, Ballast, Service tanks and others, monitored by
TA840 Gauging System .
2. General description
2.1. Functional Description
The CRI 840 is composed of a front plate 19" 3U, which can be combined with a
MICATRANS A/D rack, or installed alone in a cubicle.
It is composed of a numeric Keypad and a LCD 4 x 20 characters display. It is
connected to the C.P.U. of Safety Module TA840-I.
2.2. Users instructions
When the TA840-I is switched on, the following data are displayed during about
5 seconds :
" Esterline AUXITROL "
"
TA840-I
"
" Ver. 1.12
"
" 20-Mar-2000 "
Then following default data are displayed :
" Esterline AUXITROL "
"
"
" Date: / / "
" Time: : : "
It can be now possible to select a channel by pressing the
channel number (1 to 104) using the numeric keypad
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
MT 5082-E REV. 00
30.11.2000
All rights reserved
CRI 840
Page 4/8
a.
page 2 :
"Ch:
Tank:
"
"Temp1 :
C "
"Temp2 :
C "
"Temp3 :
C "
page 3 :
"Ch:
Tank:
"
"Ull.Temp1:
mm "
"Ull.Temp2:
mm "
"Ull.Temp3:
mm "
(Location of probes)
page 4 :
"Ch:
Tank:
"
"Min pres.:
mbar"
"Max pres.:
mbar"
"Pressure :
mbar"
(Calibration pressure)
(Calibration pressure)
page 5 :
"Ch:
Tank:
"
"Max height:
mm "
"Offset :
mm "
"Ullage :
mm "
page 6 :
"Ch:
Tank:
"
"Algo mode :
"
"Permitivity:
"
"Wave eff.reduct.: "
(calculated by Radar)
page 7 :
"Ch:
Tank:
"Temp. valid.:
"Press.valid.:
"Radio/rst valid.:
Division of
Auxitrol
Technologies
"
"
"
"
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
MT 5082-E REV. 00
30.11.2000
All rights reserved
CRI 840
Page 5/8
page 8 :
"Ch:
Tank:
"
"Offset valid. : "
"Empty tank val.: "
"TA840 revision : "
(Y or N)
(Y or N)
page 9 :
"Ch:
Tank:
"
"Autotest :
"
"MF :
ROS:
"
"Signal :
"
b.
(OK or FAULT)
(OK or FAULT);
(OK or LOW)
(OK or FAULT)
"Ch:
Tank:
"
"Current :
mA"
"Min pres.:
mbar"
"Max pres.:
mbar"
(Calibration pressure)
(Calibration pressure)
page 2 :
page 3 :
"Ch:
Tank:
"
"Min height:
mm"
"Max height:
mm"
"Slave type:
"
Division of
Auxitrol
Technologies
(Calibration height)
(Calibration height)
Slave type :
"Relative"
"FORE dr."
"AFT dra."
"PORT dr."
"STBD dr."
"Absolute"
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
MT 5082-E REV. 00
30.11.2000
All rights reserved
CRI 840
Page 6/8
c.
page 2 :
"Ch:
Tank:
"
"Min temp.:
C "
"Max temp.:
C "
"
"
d.
(Calibration temperature)
(Calibration temperature)
page 2 :
"Ch:
Trim or Heel "
"Min angle:
"
"Max angle:
"
"
"
e.
(Calibration angle)
(Calibration angle)
page 2 :
"Ch: 255 TA840-I "
"Monit.rate:
bds"
"Syst. rate:
bds"
"Syst. mode:
"
Division of
Auxitrol
Technologies
front
" Monitor."
" PCD "
" Indicat."
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
MT 5082-E REV. 00
30.11.2000
All rights reserved
CRI 840
Page 7/8
page 3 :
"Ch: 255 TA840-I "
"TRIM height:
cm"
"HEEL angle : "
"T/H valid. :
"
page 4 :
"Ch:
TA840-I "
"Qty events :
"
"Length PP :
cm"
"Syst. mode :
"
f.
(system bit Y or N)
(TA840 in failure)
";
3. Technical Characteristics
Presentation :
134 +
Display :
Weight:
Division of
Auxitrol
Technologies
1
1
mm x 448 + mm
0
0
...
keys
1 kg
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
(file:NT401rev05-03-99.doc)
Tl. +33.(0)1.49.11.65.75
Fax +33.(0)1.49.11.65.76
Auxitrol - SA au capital de 65 595 700 FRF - R.C.S. Bourges B 602 023 251- Sige Social : 5, alle Charles Path - 18941 Bourges Cedex 9 - France
(file:NT401rev05-03-99.doc)
CONTENTS
Page
11.
FAULT FINDING_______________________________________________ 9
Tl. +33.(0)1.49.11.65.75
Fax +33.(0)1.49.11.65.76
Auxitrol - SA au capital de 65 595 700 FRF - R.C.S. Bourges B 602 023 251- Sige Social : 5, alle Charles Path - 18941 Bourges Cedex 9 - France
(file:NT401rev05-03-99.doc)
Before unpacking the LIDEC, inspect the box for damage caused during shipping. If
any damage is found, contact the forwarding company and note protest until the
LIDEC is tested.
Unpack carefully the LIDEC, and check visually if there is any mechanical damage.
The LIDEC identification is located on the body of the enclosure.
2. STORAGE
Storage must be carried out using the original packing, in a dry and covered area. The
LIDEC must be shock protected.
4. OPERATING PRINCIPLE
The sensor type LIDEC detects High or Low level in any liquid, with an alarm output
given by a current loop change (18 mA to 6 mA) or a dry contact. The LIDEC can be
installed either horizontally or vertically.
Tl. +33.(0)1.49.11.65.75
Fax +33.(0)1.49.11.65.76
Auxitrol - SA au capital de 65 595 700 FRF - R.C.S. Bourges B 602 023 251- Sige Social : 5, alle Charles Path - 18941 Bourges Cedex 9 - France
(file:NT401rev05-03-99.doc)
The principle is based on the absorption of mechanical waves at the tip of the
probe. The mechanical waves are generated and detected by a piezo-electric
ceramic.
Note: due to that principle, the probe must not be painted, it must be cleaned
periodically when used with viscous liquid.
The LIDEC provides a very safe operation, the circuitry includes a fail-safe detection
which activates an alarm for the following:
-
Level alarm,
Electronic failure,
5. TECHNICAL SPECIFICATIONS
Power supply
18 to 28 V DC (24 V DC nominal)
Consumption
0.6 W
Alarm output
Alarm setting
Tl. +33.(0)1.49.11.65.75
Fax +33.(0)1.49.11.65.76
Auxitrol - SA au capital de 65 595 700 FRF - R.C.S. Bourges B 602 023 251- Sige Social : 5, alle Charles Path - 18941 Bourges Cedex 9 - France
(file:NT401rev05-03-99.doc)
Accuracy
2mm
Connections
Hysteresis
< 4 mm
Operating temperature :
- 25 to + 70C (Housing)
- 40 to + 90C (Probe)
EEx ia IIC T5
Ui = 28 Vcc
Li = 120 mA
Pi = 0,84 W
Li = 0
Ci = 25 nF
Tl. +33.(0)1.49.11.65.75
Fax +33.(0)1.49.11.65.76
Auxitrol - SA au capital de 65 595 700 FRF - R.C.S. Bourges B 602 023 251- Sige Social : 5, alle Charles Path - 18941 Bourges Cedex 9 - France
(file:NT401rev05-03-99.doc)
6. INSTALLATION
- Various types of fixation are available (Flange or Thread): (see drawing p.3)
- For thread fixation, tightness must be carried out with the appropriate product
- For flange fixation, tightness depend on the gasket fitted between the flange and
the counter flange.
Caution: When work is being carried out inside the tank or close to the probe, it is
necessary to protect the probe against shocks, sand blasting, painting,
ST1
ST4
B1
ST5
18 - 6 mA
6 - 18 mA
ST1
ST4
B1
ST5
Relay ON
without liquid
Relay OFF
without liquid
ST1
Tl. +33.(0)1.49.11.65.75
Fax +33.(0)1.49.11.65.76
Auxitrol - SA au capital de 65 595 700 FRF - R.C.S. Bourges B 602 023 251- Sige Social : 5, alle Charles Path - 18941 Bourges Cedex 9 - France
(file:NT401rev05-03-99.doc)
8. ELECTRICAL CONNECTIONS
Safety instruction: Ensure the power supply line is turned off.
8.1 - Power supply 18 to 28 V DC
8.2 - Cable specification
* Screened cable with two cores, (four cores with relay option) suitable for the
surrounding. Wire gauge to be 1.0 to 1.5 mm, except for relay option,
depending of the power switched.
NOTE :
- Be sure to respect the intrinsic safety requirements (see chapter 5)
- The screen must be connected to ground on the voltage supply side, and not
on the Lidec enclosure.
* Cable maximum outside diameter to be selected according to the type of
cable gland:
- In standard
- In option
:
:
BV1 diameter 6 to 12 mm
BV2 diameter Max. 14.5 mm
L 8.5 to 14.5 mm
Tl. +33.(0)1.49.11.65.75
Fax +33.(0)1.49.11.65.76
Auxitrol - SA au capital de 65 595 700 FRF - R.C.S. Bourges B 602 023 251- Sige Social : 5, alle Charles Path - 18941 Bourges Cedex 9 - France
(file:NT401rev05-03-99.doc)
10.
For replacement:
Tl. +33.(0)1.49.11.65.75
Fax +33.(0)1.49.11.65.76
Auxitrol - SA au capital de 65 595 700 FRF - R.C.S. Bourges B 602 023 251- Sige Social : 5, alle Charles Path - 18941 Bourges Cedex 9 - France
(file:NT401rev05-03-99.doc)
11.
FAULT FINDING
Sensor faults are generally due to errors from the following :
NO ALARM - ALARM ALWAYS ON - ALARM SETTING NOT CORRECT
ST4
B1
ST5
ST1
Tl. +33.(0)1.49.11.65.75
Fax +33.(0)1.49.11.65.76
Auxitrol - SA au capital de 65 595 700 FRF - R.C.S. Bourges B 602 023 251- Sige Social : 5, alle Charles Path - 18941 Bourges Cedex 9 - France
(file:NT401rev05-03-99.doc)
NO ALARM
Check the DC supply in 'A', it should be 18 to 28 VDV
Possible trouble:
ALARM ALWAYS ON
Check the DC supply in 'A', it should be 18 to 28 VDV
Possible trouble:
Tl. +33.(0)1.49.11.65.75
Fax +33.(0)1.49.11.65.76
Auxitrol - SA au capital de 65 595 700 FRF - R.C.S. Bourges B 602 023 251- Sige Social : 5, alle Charles Path - 18941 Bourges Cedex 9 - France
NT5090.doc
Rev. 01
page 1 / 13
Type PL 3700
TECHNICAL MANUAL
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
NT5090.doc
Rev. 01
page 2 / 13
CONTENT
1.
DESCRIPTION.................................................................................................................................................3
1.2.
APPLICATION. ................................................................................................................................................3
1.3.
2.
ADVANTAGES. ..................................................................................................................................................4
3.
3.2.
3.3.
ENVIRONMENT. ..............................................................................................................................................4
3.4.
ACCURACY ....................................................................................................................................................5
3.5.
ELECTRICAL...................................................................................................................................................5
3.6.
OTHERS: .......................................................................................................................................................6
3.7.
3.8.
TRANSMITTER DIMENSION...............................................................................................................................6
3.9.
MECHANICAL MOUNTING.................................................................................................................................7
3.10.
ELECTRICAL CONNECTING...........................................................................................................................7
4.
5.
6.
CODIFICATION ................................................................................................................................................11
6.1.
6.2.
INDEX
DRAWINGS:
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
NT5090.doc
Rev. 01
page 3 / 13
Description
The PL 3700 is a 2-wires 4-20 mA level and pressure transmitter consisting of a transducer
and an amplifier connected via a 3-core vented cable.
The transducer is fully welded and it is submersible (IP68), housed in stainless steel AISI
316L using a capacitive Ceramic diaphragm.
Amplifier is housed inside sea water-resistant polyester casing (IP 66) which can be
installed inside area protected against wave effect damage or inside sea water-resistant
stainless steel AISI 316l casing (IP66/67) with adapting flexible pipe in stainless steel which
can be installed on deck.
The PL 3700 can be manufactured with 11 different programmable ranges for level
application, it is depend the application, absolute transmitter or gauge transmitter, and with
a fixed range for pressure measurement.
The PL 3700 can be immersed and mounted inside tank using adapted bracket or on side
mounting using adapted flange.
1.2.
Application
The PL3700 has been developed for level measuring in tanks, ballast, oil, fresh water,
chemical product It covers as well drafts measuring, pressure measuring in cargo line
and inert gas measuring.
1.3.
General view
Remote box
( housing in stainless steel 316L IP66/67 )
For deck mounting
Remote box
( housing in Polyester IP66 )
For protected area mounting
Transducer
( housing in stainless steel 316L IP68 )
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
NT5090.doc
Rev. 01
page 4 / 13
2. ADVANTAGES
The ceramic capacitive pressure sensor provides a flush diaphragm, avoiding risks of sensor
clogging and ensures extremely low hysteresis, minimal output drift error and high repeatability.
Ceramic diaphragm provides outstanding corrosion resistance.
3. TECHNICAL SPECIFICATIONS
3.1.
Transducer ranges
Measure range
-200 to 1000 mbar
+900 to 1100 mbar
+800 to 2000 mbar
+0 to 20000 mbar
Admissible overload
10 bar
10 bar
18 bar
40 bar
Type of measurement
Gauge
Absolute
Absolute
Absolute
Operating Condition
3.3.
Type of measurement
Gauge
Gauge
Gauge
Gauge
Gauge
Gauge
Gauge
Absolute and Gauge
Absolute and Gauge
Absolute and Gauge
Absolute and Gauge
3.2.
Admissible overload
6 bar
6 bar
6 bar
6 bar
6 bar
6 bar
10 bar
10 bar
18 bar
18 bar
18 bar
Operating temperature.
Transducer :
-40C to +125C. (side mounting).
-40C to +100C. (immersed mounting).
Amplifier :
-40C to +85C.
Environment
Protection Class
- Transducer:
- Remote box:
IP68 at 10bar
Sea water-resistant polyester housing: IP66.
Stainless steel housing: IP66/67
Intrinsic safety for use in hazardous area
- EEx ia IIC/IIB T6, certificate number LCIE 00.E6113X with 50 m cable max
between transducer and amplifier.
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
3.4.
Accuracy
Electrical
Power supply:
12 to 30 VDC ( Maximum 28 VDC for use on hazardous area with intrinsic safety
certification ).
Permissible load resistance is shown graphically below.
Calculation formula:
U Loop 12
0.020
3.5.
NT5090.doc
Rev. 01
page 5 / 13
700
600
500
400
300
Load
Resistance
200
100
0
12
14
16
18
20
22
24
26
28
Output current:
4 20 mA DC, 2 wired system.
Adjustment:
Span adjustment of each transmitter is adjustable from 100% to 70% of
the nominal transducer range (full scale).
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
3.6.
Others
3.7.
NT5090.doc
Rev. 01
page 6 / 13
Marine classification
DNV, GL, BV.
LRS, RINA, NKK, KRS, ABS, CCS (all pending)
CE marked in accordance with EU directive.
Transmitter dimension
110
108
75
3.8.
157
110
4 holes 13
110
208
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
NT5090.doc
Rev. 01
page 7 / 13
44
~ 120
Cable OD 8 mm
Max length 50 m
3
Transducer Housing
Stainless steel 316L
Ceramic diaphragm
3.9.
Zero line
Mechanical mounting
Different types of mechanical mounting are available:
- Fixation kit in stainless steel 316L for immersed application.
- Pipe Kit in stainless steel 316L for immersed application.
- Flange PN40 DN25 in stainless steel 316L, screwed or welded.
- Flange PN16 DN40 in stainless steel 316L, screwed or welded.
.
Transducer:
Transducer is delivered with minimum 1 meter to maximum 50 meter of cable.
Correct length has to be determined by customer.
Cable is composed of 3 wires (0V, Supply & signal), 1 braid ground, one vent pipe
(gauge application) and one aluminum shield.
Transducer can be connected only to amplifier.
Supply: 5V (red)
Signal (blue)
Aluminum shield
Vent pipe
Supply: 0V (brown)
Braid ground
Amplifier box :
Polyester amplifier box is supplied
with one cable gland properly secure for transducer cable input.
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
NT5090.doc
Rev. 01
page 8 / 13
Programmable
Electronic board
Cable gland PG 13
6 to 12 mm
or Cable gland PG 16
9 to 14 mm
Transducer
Cable
Power supply
Cable
Stainless steel amplifier box is supplied with two female thread input :
- One ISO M17x 1.5 female thread for transducer input to mount adapted flexible
pipe kit in stainless steel.
- One ISO M23 x 1.5 female thread for power supply input to mount adapted
flexible pipe kit in stainless steel.
ISO M17x1.5
Female thread
For flexible kit adaptation
ISO M23x1.5
Female thread
For flexible kit adaptation
Transducer
Cable
Power supply
Cable
Programmable
Electronic board
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
NT5090.doc
Rev. 01
page 9 / 13
L1
Hv
H
hz
Tank bottom
hz
(cm)
Hv
(cm)
L1 (m)
Cable
length
Specific
gravity
Serial
Number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
NT5090.doc
Rev. 01
page 10 / 13
5. Personal notes
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
NT5090.doc
Rev. 01
page 11 / 13
6. CODIFICATION
6.1.
1
9 10 11 12 13
PL3700
| | | | | | | | | | | |
| | | | | | | | | | |
G | |
A | |
| |
3 |
1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Type of measure
Gage pressure
Absolute pressure
2 | | | | | | | | | |
A
B
C
D
E
F
G
H
J
X
Type
forbidden if abs pressure (digit
2=A)
forbidden if abs pressure (digit
2=A)
forbidden if abs pressure (digit 2=A)
forbidden if abs pressure (digit 2=A)
forbidden if abs pressure (digit 2=A)
forbidden if abs pressure (digit 2=A)
forbidden if abs pressure (digit 2=A)
all (abs and gage pressure )
all (abs and gage pressure )
all (abs and gage pressure )
all (abs and gage pressure )
On request
Environment
Non-Corrosive Product
Comment
Viton gasket ( standard )
all types
all types
all types
all types
all types
On request
On request
|
|
|
|
|
|
|
|
|
|
|
4
S
|
|
|
|
|
|
|
|
|
|
|
|
|
|
5
C
D
E
F
0
X
Y
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6
A
B
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
7
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
8
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
9
A
C
|
|
|
|
|
|
1
0
0
A
B
C
D
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Division of
Auxitrol
Technologies
Range
0 to 120 mbar (min. range 0 to 80 mbar)
Comment
Comment
all types, for protected installation
all types, for "on deck" installation
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Comment
all types
Only for SST box ( digit 9=C )
Only for polyester box (digit 9=A,B)
Only for SST box ( digit 9=C )
Only for SST box ( digit 9=C )
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
NT5090.doc
Rev. 01
page 12 / 13
9 10 11 12 13
PL3700
| | | | | | | | | |
1
1
0
1
Division of
Auxitrol
Technologies
| |
| |
|
|
|
1
2
0
1
Calibration
|
|
|
|
Standard calibration
Customized calibration
|
|
|
1
3
0
A
B
C
1
2
Comment
all types
all types
Comment
all types
all flanged types
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Comment
all types
all immerged types
all immerged types
all immerged types
all immerged types
all immerged types
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
6.2.
1
NT5090.doc
Rev. 01
page 13 / 13
9 10 11 12 13
| |
|
G |
A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
4 |
S |
C |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
PL3700
2
P
Q
R
S
X
F
P
0
Y
A
B
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
9 |
A |
C |
|
10
0
A
B
C
D
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
11 |
0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
12 |
0 |
|
13
0
A
Division of
Auxitrol
Technologies
Type
forbidden if abs pressure (digit 2=A)
forbidden if gage pressure (digit 2=G)
forbidden if gage pressure (digit 2=G)
forbidden if gage pressure (digit 2=G)
On request
Comment
Viton gasket ( standard )
Kalrez gasket, forbidden if digit 3=Q
Comment
all except atm pressure (digit 3=Q)
only for manifold pressure ( digit 3=S )
Comment
Polyethylen (PET), lenght in meter (min 01/max 50) all types, temp < 85C
Teflon (FEP), lenght in meter (min 01/max 50)
all types, high temp and corrosive atm
Electronics Housing
Polyester housing
316L stainless steel housing
all types
Only for SST box ( digit 9=C )
Only for polyester box (digit 9=A,B)
Only for SST box ( digit 9=C )
Only for SST box ( digit 9=C )
Calibration
Standard calibration
all types
all types
all types
only for atm pressure (digit 3=Q)
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Comment
Comment
Comment
Comment
Comment
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
MI5090.doc
Rev. 01
Page 1 /16
Type PL 3700
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
MI5090.doc
Rev. 01
Page 2 /16
CONTENT
1.
2.
STORAGE...........................................................................................................................................................3
3.
4.
5.
POSITIONING..................................................................................................................................................3
MOUNTING .....................................................................................................................................................3
TRANSDUCER: ...............................................................................................................................................6
REMOTE BOX : ...............................................................................................................................................7
CABLE DEFINITION : POWER SUPPLY ...............................................................................................................8
MOUNTING OF STAINLESS STEEL FLEXIBLE PIPE ...............................................................................................9
ELECTRICAL CONNECTION ............................................................................................................................10
PRECAUTIONS FOR INTRINSICALLY SAFE INSTALLATION EEX I .........................................................................10
VERIFICATION ..............................................................................................................................................11
PRELIMINARY CHECK ....................................................................................................................................11
CONTROL IN WORKING .................................................................................................................................11
SETTING ......................................................................................................................................................11
6.
7.
8.
CODIFICATION ................................................................................................................................................14
8.1.
8.2.
DRAWINGS:
INDEX
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
MI5090.doc
Rev. 01
Page 3 /16
3. MECHANICAL INSTALLATION
CAUTION:
If any kind of work are carry out inside the tanks it is necessary to protect the
diaphragm and transducer against chocks, sandblasting, painting, etc.
3.1.
Positioning
The PL3700 IS CALIBRATED FOR ONE SPECIFIC TANK ONLY. It must be installed with
corresponding tank. Each transducer has to be associated with it own amplifier box (check
serial number engraved on both equipment).
3.2.
Mounting
Different possibilities of mounting are possible : immersed or side mounting, depending of
type of tanks, liquid and pressure to measure.
Immersed mounting:
Flexible option
S.S 316L
Fixation KIT
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
MI5090.doc
Rev. 01
Page 4 /16
PL 3700
Flange mounting
Hull shell
Valve
Deck
Fixed pipe
Side tank
Fixations
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
MI5090.doc
Rev. 01
Page 5 /16
Transducer
Flange Test
PN16 DN40
PN40 DN25
Welded Flange
PIPE
PRESSURE APPLICATION
LEVEL APPLICATION
Screwed Flange
TANK
Test Flange
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
MI5090.doc
Rev. 01
Page 6 /16
4. ELECTRICAL INSTALLATION
Transducer:
(DWG: M23714, M23769, M24663, M26198.)
IMPORTANT RECOMMENDATION:
Cable isolation must be not damage (Cracks, weld spatter, burn, crush, etc).
If cable is installed without protection tube:
DO NOT:
- Tighten high until crushing of the cable with cable fixation.
- Fix cable alongside pipe with temperature which exceed 80C.
- Expose cable to chemical or corrosive product.
Cable must be bent with a maximum radius as indicated in following figure.
If radius is too small vent pipe inside cable can be crush and transducer will be
damaged.
Cable gland on top tank or tank penetration must be tighten with tightening torque
between 2.5 to 3 m/Kg maxi for not crushing vent pipe inside cable.
Cable gland
Tightening torque 2.5 to 3 m/Kg
170 mini
4.1.
Mini radius
40 mm
Bulkhead
50 mini
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
4.2.
MI5090.doc
Rev. 01
Page 7 /16
Remote box :
(DWG: M22865, M23714, M23769.)
PG 13
Cable 6 to 12mm
or PG 16
Cable 9 to 14mm
+ reducer
Transducer Input
Power supply Input
Venting
for pipe connection
1/8 NPT
Cable gland
Positioned downward
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
MI5090.doc
Rev. 01
Page 8 /16
Flexible pipe
gas x ISO M17
Flexible pipe
gas x ISO M23
Transducer Input
Venting
for pipe connection
1/8 NPT
Pipe for venting
To dry area
Dry air area
4.3.
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
4.4.
MI5090.doc
Rev. 01
Page 9 /16
(4) Washer
(1) Sealing
washer
( 6) Locking nut
Coupling
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
4.5.
MI5090.doc
Rev. 01
Page 10 /16
Electrical connection
-
G 0V Sg 5V
+_
Braid ground
Supply 0V (brown)
Ground
Signal (blue)
Supply 5V (red)
Power supply
12 30 VDC
Output
4 20 mA
4.6.
Hazardous area
Supply
12 - 30 Vdc
Current loop
Output
4 - 20mA
Zener
Shield
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
MI5090.doc
Rev. 01
Page 11 /16
Verification
Before powering ON PL3700, check the polarity on all the equipment connected to the
processing line.
5.2.
Preliminary check
Power ON PL3700.
Check the output reading ( in mA ) on PL3700 terminal block :
-
5.3.
4 mA if no liquid or no pressure.
4 to 20 mA if liquid or pressure.
Control in working
Compare level of liquid with value indicated on analog indicator or on monitoring system.
INFORMATION
- On analog indicator, scale is indicated and calculated with specific gravity used
to calibrate PL3700. Before comparing level, check if liquid inside tank has same
specific gravity. If it is different, you may have a significant error.
- Indication is without any Trim & Heel correction. If the manual sounding pipe is
not close to the PL3700, you also may have a significant difference.
- For tank with special shape, check if manual sounding pipe is not bent or if end
of pipe is not installed above or below PL3700 position. If yes you have to
compare volume according with manual sounding tables.
5.4.
Setting
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
MI5090.doc
Rev. 01
Page 12 /16
L1
Hv
H
hz
Tank bottom
hz
(cm)
Hv
(cm)
L1 (m)
Cable length
Specific
gravity
Serial
Number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
MI5090.doc
Rev. 01
Page 13 /16
7. PERSONAL NOTES
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
MI5090.doc
Rev. 01
Page 14 /16
8. CODIFICATION
8.1.
1
9 10 11 12 13
| |
|
G |
A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
4 |
S |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
PL3700
2
A
B
C
D
E
F
G
H
J
X
C
D
E
F
0
X
Y
A
B
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
9 |
A |
C |
|
10
0
A
B
C
D
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Division of
Auxitrol
Technologies
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Type of measure
Gauge pressure
Absolute pressure
Range
0 to 250 mbar (min. range 0 to 175 mbar)
0 to 350 mbar (min. range 0 to 250 mbar)
0 to 500 mbar (min. range 0 to 350 mbar)
0 to 700 mbar (min. range 0 to 500 mbar)
0 to 1000 mbar (min. range 0 to 700 mbar)
0 to 1400 mbar (min. range 0 to 1000 mbar)
0 to 2000 mbar (min. range 0 to 1400 mbar)
0 to 2800 mbar (min. range 0 to 2000 mbar)
0 to 4000 mbar (min. range 0 to 2800 mbar)
Other range
Type
Environment
Non-Corrosive Product
all types
all types
all types
all types
all types
On request
On request
Comment
Comment
Comment
Polyethylen (PET), lenght in meter (min 01/max 50) all types, temp < 85C
Teflon (FEP), lenght in meter (min 01/max 50)
all types, temp < 125C
Electronics Housing
Polyester housing
316L stainless steel housing
all types
Only for SST box ( digit 9=C )
Only for polyester box (digit 9=A,B)
Only for SST box ( digit 9=C )
Only for SST box ( digit 9=C )
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Comment
Comment
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
MI5090.doc
Rev. 01
Page 15 /16
9 10 11 12 13
PL3700
| | | | | | | | | | |
11 |
0 |
1 |
|
|
|
|
|
|
12 |
0 |
1 |
|
13
0
A
B
C
1
2
Division of
Auxitrol
Technologies
Calibration
Standard calibration
Customized calibration
all types
all types
Comment
all types
all flanged types
Comment
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
8.2.
1
MI5090.doc
Rev. 01
Page 16 /16
9 10 11 12 13
PL3700
| | | | | | | | | | | |
| | | | | | | | | | |
G | |
A | |
| |
3 |
1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Type of measure
Gage pressure
Absolute pressure
2 | | | | | | | | | |
A
B
C
D
E
F
G
H
J
X
Type
forbidden if abs pressure (digit
2=A)
forbidden if abs pressure (digit
2=A)
forbidden if abs pressure (digit 2=A)
forbidden if abs pressure (digit 2=A)
forbidden if abs pressure (digit 2=A)
forbidden if abs pressure (digit 2=A)
forbidden if abs pressure (digit 2=A)
all (abs and gage pressure )
all (abs and gage pressure )
all (abs and gage pressure )
all (abs and gage pressure )
On request
Environment
Non-Corrosive Product
Comment
Viton gasket ( standard )
all types
all types
all types
all types
all types
On request
On request
|
|
|
|
|
|
|
|
|
|
|
4
S
|
|
|
|
|
|
|
|
|
|
|
|
|
|
5
C
D
E
F
0
X
Y
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6
A
B
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
7
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
8
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
9
A
C
|
|
|
|
|
|
1
0
0
A
B
C
D
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Division of
Auxitrol
Technologies
Range
0 to 120 mbar (min. range 0 to 80 mbar)
Comment
Comment
all types, for protected installation
all types, for "on deck" installation
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Comment
all types
Only for SST box ( digit 9=C )
Only for polyester box (digit 9=A,B)
Only for SST box ( digit 9=C )
Only for SST box ( digit 9=C )
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
MM5090
Rev. 01
Page 1 / 15
Type PL 3700
MAINTENANCE
MANUAL
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
MM5090
Rev. 01
Page 2 / 15
CONTENT
1.
2.
DESCRIPTION....................................................................................................................................................3
3.
MAINTENANCE ..................................................................................................................................................3
PERIODIC CONTROL........................................................................................................................................3
ZERO AND SPAN CALIBRATION ......................................................................................................................4
3.1.
3.2.
4.
RE-CALIBRATING ..............................................................................................................................................6
PL3700 CONFIGURATION ...............................................................................................................................6
CALIBRATION .................................................................................................................................................8
4.1.
4.2.
5.
TROUBLESHOOTING ........................................................................................................................................8
6.
7.
8.
9.
10.
CODIFICATION.............................................................................................................................................13
10.1.
10.2.
INDEX
DRAWINGS:
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
MM5090
Rev. 01
Page 3 / 15
2. DESCRIPTION
REFER TO TECHNICAL MANUAL NT5090
3. MAINTENANCE
3.1.
Periodic control
Auxitrol SA recommends yearly checking of:
Transducer:
- Visual inspection of cable.
- Ceramic membrane is not obstructed by any dirty.
Remote box:
- Visual inspection of cables.
- Flexible pipes are not damaged.
- Cable glands are correctly tightened.
- Venting pipe is not obstructed by any dirty.
Zero and span calibration.
- See procedure 3.2.
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
OFF
Bu
SPAN
Bw
ZERO
ON
1
2
3
4
5
6
RANGE
TAG
+ -
0v
S/N
24v
3.2.
MM5090
Rev. 01
Page 4 / 15
PL3700
Ammeter
Power supply
12 30 VDC
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
MM5090
Rev. 01
Page 5 / 15
Example:
PL3700 absolute range: 900 to 1100 mbar.
- 4.00 mA = 900 mbar
- 20.00 mA = 1100 mbar
- Span = 1100 900 = 200 mbar
Actual value from atmospheric pressure = 996 mbar.
Calibration using test pressure equipment.
To test or calibrate absolute pressure sensor, using vacuum test pressure
equipment is recommended. Gauge test pressure equipment can be used
( depending on its capability to generated vacuum pressure ).
Connect test pressure equipment.
Pressure test to apply = 900 mbar ( abs pressure ) or -100 mbar (gauge).
If readings = 4.00 mA, correct.
If readings <> 4.00 mA 0.3%, adjust Zero potentiometer.
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
MM5090
Rev. 01
Page 6 / 15
Example:
To test or calibrate absolute pressure sensor, using vacuum test pressure
equipment is recommended. Gauge test pressure equipment can also be used.
PL3700 absolute range: 900 to 1100 mbar.
- 4,00 mA = 900 mbar
- 20.00 mA = 1100 mbar
- Span = 1100 900 = 200 mbar
Actual value from atmospheric pressure = 996 mbar.
- Pressure test to apply = 200 mbar -96 mbar = 104 mbar ( gauge pressure )
or 1100 mbar ( absolute pressure ).
If readings = 20,00 mA, correct.
If readings <> 20,00 mA 0.3%, adjust Span potentiometer.
4. RE-CALIBRATING
4.1.
PL3700 configuration
According to the nominal span of transducer and calibrated span needed by customer, it
is necessary to place switches according to following table.
Switches
1
2
3
4
5
6
Division of
Auxitrol
Technologies
100%
OFF
OFF
OFF
ON
OFF
ON
% of SPAN
90%
80%
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
OFF
ON
ON
ON
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
70%
OFF
OFF
ON
OFF
ON
ON
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
MM5090
Rev. 01
Page 7 / 15
In case of change the calibration on an existing tank (zero position or maximum tank
height are changed), you can use the same PL3700 only if new calibration is still inside
70% of full span (check with following example).
If it is not the case, you have to exchange to a new, adapted PL3700 (refer to table
2.2.).
Example:
The measuring range is indicated in mbar on transducer and associated remote box.
The indicated value corresponds to the maximum hydrostatic pressure calculated as
follow (for help use PTDQ 8).
P = (H-hz) x Sg x 0,981
P = Hydrostatic pressure. (mbar)
H = Total height to gauge. (cm)
Hz = Zero line. (cm)
Sg = Specific gravity of liquid.
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
4.2.
MM5090
Rev. 01
Page 8 / 15
Calibration
5. TROUBLESHOOTING
Trouble
Possible trouble
Indication
Error
Action
- Zero setting
- Adjust Zero
- Span setting
- Adjust Span
- Specific gravity
Indication still
Maximum
- Faulty sensor
- Replace sensor
- Faulty sensor
- Replace sensor
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
MM5090
Rev. 01
Page 9 / 15
Information
requested
DESIGNATION
Remote box in Polyester
Remote box in Stainless steel
Flexible pipe
Electronic board
Transducer
Fixation kit
Flange
Serial
number
QUANTITY
5 weeks
5 weeks
5 weeks
5 weeks
5 weeks
5 weeks
5 weeks
Size
Division of
Auxitrol
Technologies
Delay
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
MM5090
Rev. 01
Page 10 / 15
Customers references
Date of order
Customers signing
Company:
Contact:
Tel:
Fax:
Address:
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
MM5090
Rev. 01
Page 11 / 15
L1
Hv
H
hz
Tank bottom
hz
(cm)
Hv
(cm)
L1 (m)
Cable length
Specific
gravity
Serial
Number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
MM5090
Rev. 01
Page 12 / 15
9. PERSONAL NOTES
Division of
Auxitrol
Technologies
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
MM5090
Rev. 01
Page 13 / 15
10. CODIFICATION
10.1. Level transmitter PL3700
1
9 10 11 12 13
PL3700
| | | | | | | | | | | |
| | | | | | | | | | |
G | |
A | |
| |
3 |
1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Type of measure
Gage pressure
Absolute pressure
2 | | | | | | | | | |
A
B
C
D
E
F
G
H
J
X
Type
forbidden if abs pressure (digit
2=A)
forbidden if abs pressure (digit
2=A)
forbidden if abs pressure (digit 2=A)
forbidden if abs pressure (digit 2=A)
forbidden if abs pressure (digit 2=A)
forbidden if abs pressure (digit 2=A)
forbidden if abs pressure (digit 2=A)
all (abs and gage pressure )
all (abs and gage pressure )
all (abs and gage pressure )
all (abs and gage pressure )
On request
Environment
Non-Corrosive Product
Comment
Viton gasket ( standard )
all types
all types
all types
all types
all types
On request
On request
|
|
|
|
|
|
|
|
|
|
|
4
S
|
|
|
|
|
|
|
|
|
|
|
|
|
|
5
C
D
E
F
0
X
Y
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6
A
B
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
7
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
8
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
9
A
C
|
|
|
|
|
|
1
0
0
A
B
C
D
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Division of
Auxitrol
Technologies
Range
0 to 120 mbar (min. range 0 to 80 mbar)
Comment
Comment
all types, for protected installation
all types, for "on deck" installation
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Comment
all types
Only for SST box ( digit 9=C )
Only for polyester box (digit 9=A,B)
Only for SST box ( digit 9=C )
Only for SST box ( digit 9=C )
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
MM5090
Rev. 01
Page 14 / 15
9 10 11 12 13
PL3700
| | | | | | | | | | |
11 |
0 |
1 |
|
|
|
|
|
|
12 |
0 |
1 |
|
13
0
A
B
C
1
2
Division of
Auxitrol
Technologies
Calibration
Standard calibration
Customized calibration
all types
all types
Comment
all types
all flanged types
Comment
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
MM5090
Rev. 01
Page 15 / 15
9 10 11 12 13
| |
|
G |
A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
4 |
S |
C |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
PL3700
2
P
Q
R
S
X
F
P
0
Y
A
B
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
9 |
A |
C |
|
10
0
A
B
C
D
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
11 |
0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
12 |
0 |
|
13
0
A
Division of
Auxitrol
Technologies
Type
forbidden if abs pressure (digit 2=A)
forbidden if gage pressure (digit 2=G)
forbidden if gage pressure (digit 2=G)
forbidden if gage pressure (digit 2=G)
On request
Comment
Viton gasket ( standard )
Kalrez gasket, forbidden if digit 3=Q
Comment
all except atm pressure (digit 3=Q)
only for manifold pressure ( digit 3=S )
Comment
Polyethylen (PET), lenght in meter (min 01/max 50) all types, temp < 85C
Teflon (FEP), lenght in meter (min 01/max 50)
all types, high temp and corrosive atm
Electronics Housing
Polyester housing
316L stainless steel housing
all types
Only for SST box ( digit 9=C )
Only for polyester box (digit 9=A,B)
Only for SST box ( digit 9=C )
Only for SST box ( digit 9=C )
Calibration
Standard calibration
all types
all types
all types
only for atm pressure (digit 3=Q)
AUXITROL S.A.
168, Bureaux de la Colline
92213 Saint-Cloud cedex
France
Comment
Comment
Comment
Comment
Comment
Tel. : + 33.(0)1.49.11.65.75
Fax : + 33.(0)1.49.11.65.76
Email : systemes.dir@auxitrol.com
An Esterline
Technologies
Company
5-1
5-2