Sepam 1000+ series 40

Presentation

MT10357

The Sepam 1000+ series 40 family of protection and metering units is designed for
the operation of machines and electrical distribution networks of industrial
installations and utility substations for all levels of voltage.
The Sepam 1000+ series 40 family consists of simple, high-performing solutions,
suited to demanding applications that call for current and voltage metering.
Sepam 1000+ series 40 selection guide by application
Selection criteria
Measurements

Series 40
I and U

Specific protection functions

I and U

I and U

Directional earth fault

Directional earth fault


and phase overcurrent

Applications
Substation

S40

Transformer

T40

Motor

S41

S42
T42

M41

Main functions

Sepam 1000+ a modular solution.

Protection
# phase overcurrent protection and earth fault protection with adjustable reset time
and switching of the active group of settings and logic discrimination
# earth fault protection insensitive to transformer switching
# RMS thermal overload protection that takes into account external operating
temperature and ventilation operating rates
# directional earth fault protection suitable for all earthing systems, isolated,
compensated or impedant neutral
# directional phase overcurrent protection with voltage memory
# voltage and frequency protection functions (under/over, ).
Communication
Sepam 1000+ is totally compatible with the Modbus communication standard.
All the data needed for centralized equipment management from a remote
monitoring and control system are available via the Modbus communication port:
# reading: all measurements, alarms, protection settings,...
# writing: breaking device remote control orders,... .
Diagnosis
3 types of diagnosis data for improved operation:
# network and machine diagnosis: tripping current, context of the last 5 trips,
unbalance ratio, disturbance recording
# switchgear diagnosis: cumulative breaking current, trip circuit supervision,
operating time
# diagnosis of the protection unit and additional modules: continuous self-testing,
watchdog.
Control and monitoring

# circuit breaker program logic ready to use, requiring no auxiliary relays or


Sepam 1000+ with basic UMI and with fixed advanced UMI.

additional wiring

# adaptation of control functions by a boolean equation editor


# preprogrammed, customizable alarm messages on messages on UMI.

User Machine Interface


2 levels of User Machine Interface (UMI) are available according to the users needs:
# basic UMI:
an economical solution for installations that do not require local operation (run via a
remote monitoring and control system)
# fixed or remote advanced UMI:
a graphic LCD display and 9-key keypad are used to display the measurement and
diagnosis values, alarm and operating messages and provide access to protection
and parameter setting values, for installations that are operated locally.

Expert UMI software


The SFT2841PC software tool gives access to all the Sepam 1000+ functions, with
all the facilities and convenience provided by a Windows type environment.
Example of an SFT2841 software screen (expert UMI).

1/2

Schneider Electric

Sepam 1000+ series 40

Selection table

Functions
Protection
Phase overcurrent
Earth fault, sensitive earth fault
Breaker failure
Negative sequence / unbalance
Directional phase overcurrent
Directional earth fault
Active overpower
Thermal overload
Phase undercurrent
Locked rotor, excessive starting time
Starts per hour
Positive sequence undervoltage
Remanent undervoltage
Phase-to-phase undervoltage
Phase-to-neutral undervoltage
Phase-to-phase overvoltage
Neutral voltage displacement
Negative sequence overvoltage
Overfrequency
Underfrequency
Recloser (4 cycles)
Thermostat / Buchholz
Temperature monitoring (with MET148, 2 set points per sensor)

ANSI code
50/51
50N/51N
50BF
46
67
67N/67NC
32P
49RMS
37
48/51LR
66
27D/47
27R
27(3)
27S(3)
59(3)
59N
47
81H
81L
79

Type of Sepam
Substation
S40
S41
4
4
4
4
1(1)
1(1)
2
2
2
1(1)

2
2
2
2
1
2
4

2
2
2
2
1
2
4

2
2
2
2
1
2
4

Transformer
T40(1)
T42(1)
4
4
4
4
1
1
2
2
2
2
2

2
2
2
2
1
2
4

2
2
2
2
1
2
4

Motor
M41(1)
4
4
1
2
2
1
2
1
1
1
2
1
2
2
2
2
1
2
4

8/16

8/16

8/16

#
#
#
#
#
#
#
#

#
#
#
#
#
#
#
#
5

#
#
#
#
#
#
#
#
5

#
#
#
#
#
#
#
#
5

#
#
#
#
#

#
#
#
#
#
#
#
#
#

#
#
#
#
#
#
#
#
#

#
#
#
#
#
#
#
#
#
#
#

#
5
5
#

#
5
5
#

#
5
5
#

#
5
5
#

#
5
#
#

#
5
#
#

#
5
#
#

#
5
#
#

5
5
5

5(4)
5
5
5

5(4)
5
5
5

5(4)
5
5
5

38/49T

Metering
Phase current I1,I2,I3 RMS, Residual current Io
#
#
Average current I1,I2,I3, Peak demand phase currents
#
#
Voltage U21, U32, U13, V1, V2, V3, Residual voltage Vo
#
#
Positive sequence voltage Vd / rotation direction
#
#
Negative sequence voltage Vi
#
#
Frequency
#
#
Active and reactive power P and Q, Peak demand P and Q, Power factor
#
#
Active and reactive energy (Wh, VARh)
#
#
Temperature measurement
Network and machine diagnosis
Tripping current I1, I2,I3, Io
#
#
Tripping context
#
#
Unbalance ratio / negative sequence current Ii
#
#
Phase angle o, 1, 2, 3
#
#
Disturbance recording
#
#
Thermal capacity used
Remaining operating time before overload tripping
Waiting time after overload tripping
Running hours counter / operating time
Starting current and time
Start inhibit time delay, number of starts before inhibition
Switchgear diagnosis
Cumulative breaking current
#
#
Trip circuit supervision
5
5
Number of operations, Operating time, Charging time
5
5
CT / VT supervision
#(1)
#(1)
Control and monitoring
Circuit breaker / contactor control(2)
#
#
Logic discrimination
5
5
Switching of setting groups
#
#
Program logic parameter setting (boolean equation editor: AND, OR, ...)
#(1)
#(1)
Additional modules
8 temperature sensor inputs - MET148 module
1 low level analog output - MSA141 module
5(1)
5(1)
Logic inputs / outputs - MES108 (4I/4O) or MES114 (10I/4O) module
5
5
RS 485 interface - ACE949-2 (2-wire) or ACE959 (4-wire) module
5
5
# standard, 5 according to parameter setting and MES108, MES114 or MET148 input/output module options
(1) available in 2002.
(2) for shunt trip unit or undervoltage release coil.
(3) exclusive choice of phase-to-neutral or phase-to-phase voltage for each of the 2 relays.
(4) 2 modules possible.

Schneider Electric

S42(1)
4
4
1
2
2
2
1

1/3

Sepam 1000+ series 40

Electrical characteristics

Analog inputs
Current transformer
1 A or 5 A CT (with CCA630)
1 A to 6250 A ratings

input impedance
consumption

Voltage transformer
220 V to 250 kV ratings

permanent thermal withstand


1 second overload
input impedance
input voltage
permanent thermal withstand
1 second overload

< 0.001
< 0.001 VA to 1 A
< 0.025 VA to 5 A
3 In
100 In
> 100 k
100 to 230/3 V
230 V
480 V

Temperature sensor input


Type of temperature sensor
Pt 100
Ni 100 / 120
Isolation from earth
no
no
Current injected in sensor
4 mA
4 mA
Logic inputs
Voltage
24 to 250 V dc
-20/+10 %
Consumption
3 mA typical
Switching threshold (2)
14 V typical
Control output relays (O1, O2, O11 contacts)
Voltage
dc
24 / 48 V dc
127 V dc
220 V dc
ac (47.5 to 63 Hz)
Continuous current
8A
8A
8A
Breaking
resistive load
8/4A
0.7 A
0.3 A
capacity
L/R load < 20 ms
6/2A
0.5 A
0.2 A
L/R load < 40 ms
4/1A
0.2 A
0.1 A
resistive load
load p.f. > 0.3
Making
< 15 A for 200 ms
capacity
Indication relay outputs (O3, O4, O12, O13, O14 contacts)
Voltage
dc
24 / 48 V dc
127 V dc
220 V dc
ac (47.5 to 63 Hz)
Continuous current
2A
2A
2A
Breaking
L/R load < 20ms
2/1A
0.5 A
0.15 A
capacity
load p.f. > 0.3
Power supply
range
deactivated consump.(1)
max. consumption(1)
24 / 250 Vdc
-20 % +10 %
3 to 6 W
7 to 11 W
110 / 240 Vac
-20 % +10 %
3 to 6 W
9 to 25 W
47.5 to 63 Hz
brownout withstand
20 ms
Analog output
Current
4 - 20 mA, 0 - 20 mA, 0 - 10 mA
Load impedance
< 600 (wiring included)
Accuracy
0.50 %
(1) according to configuration.
(2) for upper values, please consult us.

1/4

(19.2 to 275 V dc)

100 to 240 V ac
8A

8A
5A

100 to 240 V ac
2A
1A
inrush current
< 28 A 100 s
< 28 A 100 s

Schneider Electric

Sepam 1000+ series 40

Isolation
Dielectric withstand at power frequency
1.2 / 50 s impulse wave
Electromagnetic compatibility
Fast transient bursts
1 MHz damped oscillating wave
Immunity to radiated fields
Immunity to conducted RF disturbances
Electrostatic discharge
Conducted disturbance emission
Disturbing field emission
Mechanical robustness
Degree of protection

Vibrations
Shocks / jolts
Earthquakes
Fire resistance
Climatic withstand
Operation
Storage
Damp heat

Environmental characteristics

IEC 60255-22-4
IEC 61000-4-4
IEC 60255-22-1
IEC 61000-4-3
IEC 61000-4-6
IEC 60255-22-2
IEC 61000-4-2
EN 55022 / CISPR 22
EN 55022 / CISPR 22

class IV
level IV
class III
level III
level III
class III
level III
class B
class A

IEC 60529

IP 52 (7)

IEC 60255-21-1
IEC 60255-21-2
IEC 60255-21-3
IEC 60695-2-1

class II (5)
class II( 5)
class II (5)
glow wire

IEC 60068-2-1 and 2


IEC 60068-2-1 and 2
IEC 60068-2-3

Effect of corrosion
IEC-68054-4
Certification
CE
UL508 (6)
(1) except for communication 1 kVrms.
(2) except for communication 3 kV common mode, 1 kV differential mode.
(3) generic EN 50081-1 standard.
(4) generic EN 50081-2 standard.
(5) intrinsic withstand of product, excluding support equipment.
(6) please consult us.
(7) a gasket delivered with the product can be used to ensure NEMA12 withstand.

Schneider Electric

2 kVrms - 1mn (1)


5 kV (2)

IEC 60255-5
IEC 60255-5

10 V/m
10 V
6 kV / 8 kV (contact / air)
on auxiliary supply (3)
(4)

on front panel
other sides closed
(except for rear IP 20)

650 C
-25C to + 70C
-25C to +70C
93% RH at 40C
56 days (storage)
10 days (operation)

class I