AT TACHMENTS

C15 / C18
Integral and Sub-Base
Fuel Tanks
US Sourced
Diesel Generator Set
320 600 kW 60 Hz
Image shown may not reflect actual package.

FEATURES
UL listed for United States (UL 142) and Canada
(ULC S601)
Compliant with NFPA 30, 37 & 110 and CSA
C282-09 & B139-09 standards.
Dual wall
Lockable fuel fill cap, 4 (101.6mm) NPT
Fuel fill drop tube with in 6 (152mm) from
bottom of tank
Low fuel level warning standard, customer
configurable warning or shutdown
Primary tank leak detection switch in containment
basin
Tank design provides capacity for thermal
expansion of fuel
Fuel supply dip tube is positioned so as not to
pick up fuel sediment
Fuel return and supply dip tube is separated by an
internal baffle to prevent immediate re-supply of
heated return fuel
Pressure washed with an iron phosphate solution
Interior tank surfaces coated with a solvent-based
thin-film rust preventative
Heavy guage steel gussets with internal lifting
rings
Primary and secondary tanks are leak tested at
20.7 kPa (3 psi) minimum
Compatible with open packages and enclosures
Gloss black polyester alkyd enamel exterior paint
Welded steel containment basin (minimum of
110% of primary tank capacity)
Direct reading fuel gauge with variable electrical
output
Emergency vents on primary and secondary tanks
are sized in accordance with NFPA 30
LEHE0467-01

DESCRIPTION Sub Base


The sub-base fuel tank mounts below the
generator set wide base

DESCRIPTION Integral

Integral diesel fuel tank is incorporated into the


generator set base frame
Robust base design includes linear vibtration
isolators between tank base and engine generator

OPTIONS
Audio/visual fuel level alarm panel
5 gal (18.9 L ) spill containment
Overfill prevention valve

AT TACHMENTS
INTEGRAL & SUB-BASE FUEL TANK BASE USEABLE CAPACITIES with Fuel Tank Dimensions & Weights
Integral Width (W) 2014 mm (79.3 in)
Sub-base Width (W) 2056 mm (81 in)
OPEN SET & WEATHER PROTECTIVE ENCLOSURE
C15 Tank
Design

Feature
Code

Total Capacity

Useable Capacity

TANK ONLY

Liter

Gallon

Liter

Gallon

kg

lb

mm

in

mm

in

mm

in

mm

in

Integral

FTDW002

1261

333

1215

321

1015

2,237

635

25

3814

150.1

2426

95.5

3200

126.0

Dry Weight

Height H

TANK AND PACKAGE


Length L

Open Pgs
Height

Enc. Pgs
Height

Sub-Base

FTDW0010

2763

730

2498

660

1468

3,236

635

25

3810

150.0

2766

108.9

3537

139.3

Sub-Base

FTDW005

3921

1036

3793

1002

1659

3,657

635

25

5550

218.5

2766

108.9

3537

139.3

Sub-Base

FTDW006

7192

1900

7022

1855

2228

4,912

889

35

6184

243.5

3020

118.9

3793

149.3

C18 Tank
Design

Feature
Code

Liter

Gallon

Liter

Gallon

kg

lb

mm

in

mm

in

mm

in

mm

in

Integral

FTDW004

1457

385

1400

370

1060

2,337

635

25

3814

150.1

2400

94.5

3200

126.0

Total Capacity

Useable Capacity

TANK ONLY
Dry Weight

Height H

TANK AND PACKAGE


Length L

Open Pgs
Height

Enc. Pgs
Height

Sub-Base

FTDW0010

2763

730

2498

660

1468

3,236

635

25

3810

150.0

2740

107.9

3537

139.3

Sub-Base

FTDW005

3922

1036

3793

1002

1659

3,657

635

25

5550

218.5

2740

107.9

3537

139.3

Sub-Base

FTDW007

8384

2215

8176

2160

2150

4,134

889

35

7073

278.5

2994

117.9

3793

149.3

INTEGRAL & SUB-BASE FUEL TANK BASE USEABLE CAPACITIES with Fuel Tank Dimensions & Weights
Integral Width (W) 2014 mm (79.3 in)
Sub-base Width (W) 2056 mm (81 in)
SOUND ATTENUATED ENCLOSURE
C15 Tank
Design

Feature
Code

Liter

Gallon

Liter

Gallon

kg

lb

mm

in

mm

in

mm

in

mm

in

Integral

FTDW001

1261

333

1215

321

1015

2,237

635

25

4753

187.1

NA

NA

2619

103.1

Sub-Base

FTDW0011

2763

730

2498

660

1468

3,236

635

25

4743

186.7

NA

NA

2955

116.3

Sub-Base

FTDW005

3922

1036

3793

1002

1659

3,657

635

25

5550

218.5

NA

NA

2955

116.3

Sub-Base

FTDW006

7192

1900

7022

1855

2228

4,912

889

35

6184

243.5

NA

NA

3209

126.3

C18 Tank
Design

Feature
Code

Liter

Gallon

Liter

Gallon

kg

lb

mm

in

mm

in

mm

in

mm

in

Integral

FTDW003

1457

385

1400

370

1060

2,337

635

25

4753

187.1

NA

NA

2557

100.7

Sub-Base

FTDW0011

2763

730

2498

660

1468

3,236

635

25

4743

186.7

NA

NA

2897

114.1

Sub-Base

FTDW005

3921

1036

3793

1002

1659

3,657

635

25

5550

218.5

NA

NA

2897

114.1

Sub-Base

FTDW007

8384

2215

8176

2160

2150

4,740

889

35

7073

278.5

NA

NA

3155

124.2

LEHE0467-01

Total Capacity

Useable Capacity

TANK ONLY
Dry Weight

Total Capacity

Useable Capacity

Height H

TANK AND PACKAGE


Length L

TANK ONLY
Dry Weight

Height H

Open Pgs
Height

Enc. Pgs
Height

TANK AND PACKAGE


Length L

Open Pgs
Height

Enc. Pgs
Height

AT TACHMENTS

The heights listed above do not include lumber used during manufacturing and shipping.

ESTIMATED RUN TIMES (HOURS) AT 100% LOAD


C15
Tank Design

Feature Code

Standby Ratings (ekW)


500

450

Prime Ratings (ekW)

400

350

455

410

365

320

Integral

FTDW001/2

10

11

10

10

11

12

Sub-Base

FTDW0010/11

18

19

21

23

20

20

23

25

Sub-Base

FTDW005

27

29

31

35

30

31

34

37

Sub-Base

FTDW006

51

53

58

65

56

57

63

69

C18
Tank Design

Feature Code

Standby Ratings (ekW)


600

Prime Ratings (ekW)

550

545

500

Integral

FTDW003/4

10

Sub-Base

FTDW0010/11

15

17

17

18

Sub-Base

FTDW005

23.5

25

25

27

Sub-Base

FTDW007

51

54

54

59

Tanks with full electrical stub-up area include removable end channel. Tanks with RH/LH stub-up include stub-up area directly below the circuit
breaker or power terminal strips. Dimensions include weather-protective enclosure exhaust system.
Dual wall sub-base tanks are UL listed and constructed in accordance with Underwriters Laboratories Standard UL142 Steel Aboveground
Tanks for Flammable and Combustible Liquids and Canada ULC S601 Shop Fabricated Steel Aboveground Tanks for Flammable and
Combustible Liquids.
Fuel tanks comply with the following United States NFPA Codes:
NFPA 30 Flammable and Combustible Liquids Code
NFPA 37 Standard for Installation and Use of Stationary Combustible Engine
NFPA 110 Standard for Emergency and Standby Power Systems
Fuel tanks comply with the following Canadian Codes:
CSA C282-09 Emergency Electrical Power Supply for Buildings
CSA B139-09 Installation Code for Oil-Burning Equipment

www.Cat-ElectricPower.com
2014 Caterpillar
All rights reserved.
Materials and specifications are subject to change without notice.
The International System of Units (SI) is used in this publication.

LEHE0467-01

(07/14)

CAT, CATERPILLAR, their respective logos, Caterpillar Yellow, the


Power Edge trade dress, as well as corporate and product
identity used herein, are trademarks of Caterpillar and may not be
used without permission.

You might also like