Product Catalog - Product Sheets

Work smarter and get the


complete overview of Danfoss
DHW Systems & Water
Heaters for domestic hot water
and district heating applications

60C
water temperature
ensures thermal
disinfection
during hot water
production

www.district-heating.danfoss.com

Index
3

Termix One Solar

Termix Novi

Akva Vita II

10

Akva Lux II GW

12

ThermoDual

14

Termix One-B with complete insulation

16

ThermoDual

26

Akva Therm II LV

28

Termix One-B

30

Akva Lux II, fully insulated

32

Termix One Solar Light

34

ThermoClean

42

ThermoDual CM

46

ThermoDual FLS

50

ThermoClean

Substations for multi-family and single-family homes


Termix One Solar
Termix Novi
Akva Vita II
Akva Lux II GW
ThermoDual
Termix One-B with complete insulation
ThermoDual
Akva Therm II LV
Termix One-B
Akva Lux II, fully insulated
Termix One Solar Light
ThermoClean
ThermoDual CM
ThermoDual FLS

Termix One Solar


Domestic hot water module for flats, single-family houses
and apartment buildings with up to 10 apartments
Domestic hot water module with heat exchanger and thermostatic control.
Designed for wall-mounting.
Application
The Termix One Solar is an instantaneous
water heater, featuring superb heat
extraction and high performance. The
Termix One Solar is applicable for heating
systems with buffer accumulators,
solar systems or for other heat sources,
where a very low return temperature is
preferred. The water heater is available in
three sizes, either for 1 apartment, for 1-4
apartments or for 5 up to 10 apartments.
The large heat exchanger cools out the
water in the primary return line very efficien
tly, thereby creating a very good operation
economy. A flow switch in cold water mains
is controlling the primary heating pump.
An optional circulation pump together with
a thermostat can maintain the circulating
temperature at a desired temperature.
Domestic hot water (DHW)
The domestic hot water is prepared in
the heat exchanger and the temperature
is regulated with a thermostatic control
valve. The patented sensor accelerator
accelerates the closing of the thermostatic

VC.LC.G4.02 Danfoss 05/2012

control valve and protects the heat


exchanger against overheating and lime
scale formation. The sensor accelerator
and the thermostatic control valve
also works as a bypass keeping the
heat exchanger and supply line warm.
This shortens the waiting periods.
The sensor accelerator helps to ensure
a stable hot water temperature by varying
loads, flow temperatures and differential
pressure without the need for readjusting
the valve. There is no additional pressure
loss on the secondary side of the DHW heat
exchanger with a thermostatic control.
Therefore this type of regulation can be
used by low pressure in the cold water
mains.
Options
The water heater can be supplied with
built in non-return valve and safety valve
mounted in the cold water supply.

Construction
All pipes are made of stainless steel.
The connections are made by nuts and
gaskets. The Termix One Solar is delivered
with an attractive steel grey cover in mo
dern design, emphasising the high level
of quality and comfort which characterises
this product.

FEATURES AND BENEFITS


Domestic hot water module
DHW regulation with an accelerated
thermostatic control
Capacity: Up to 90 kW on DHW
DHW in sufficient quantity
Operates independent of differential
pressure and flow temperature
Minimum space required for
installation
Pipes and plate heat exchanger made
of stainless steel
Minimized risk of lime scale
and bacteria formation

Termix One Solar


Circuit diagram - example

BT
supply

DHW

BT
return

DCW

BT
supply

DHW
Cirk.

BT
return

DCW

Technical parameters:
Nominal pressure:
DH supply temperature:
DCW static pressure:
Brazing material (HEX):

With circulation:
Without cover:
With cover:

Termix One Solar


with circulation
O Termix Sensor Accelerator
B Plate heat exchanger DHW
1 Ball valve
2 Single check valve
4 Safety valve
7 Thermostatic valve
11 Circulation pump DHW
13 Charging pump

H 960 B 400 T 190


H 960 B 400 T 190

20 kg
(incl. packing)

Weight incl. cover:


Cover:

PN 16
Tmax = 120 C
pmin = 0,5 bar
Copper

Termix One Solar


O Termix Sensor Accelerator
B Plate heat exchanger DHW
1 Ball valve
2 Single check valve
7 Thermostatic valve
13 Charging pump
35 Ball valve/non-return valve

24 Delivered
loose with unit
35 Ball valve
/ non-return valve
39 Connection closed
45 Flow switch
48 Air vent, manual
63 Sieve

Connections:
1 Domestic cold water (DCW)
2 Domestic hot water (DHW)
3 Buffer tank (BT) supply
4 Buffer tank (BT) return
5 Circulation
Connections sizes:
All connections:

Grey-lacquered
steel sheet

39 Connection closed
45 Flow switch
48 Air vent, manual
63 Sieve

G (int. thread)

Wall

Dimensions (mm):
Without cover:
H 760 B 312 T 155
With cover:
H 760 B 315 T 165
Without cover, with circulation:


H 935 B 410 T 150

Seen from above

DHW: Capacity examples, 10C/50C


Substation type
Type 1
w/AVTB 15
1 household
Type 3
w/AVTB 20
5 to 10* households

DHW
Capacity
kW
29.3
38.2
37.8
52.3
60
66
80
90

Supply
flow
Primary
C
60
60
70
70
60
60
70
70

Return
flow
Primary
C
23.0
25.2
20.0
22.4
23.0
24.0
20.3
21.0

Pressure
loss
Primary
kPa
20
45
20
45
35
45
35
45

Flow
rate
Secondary
l/h
630
822
816
1128
1280
1426
1730
1940

Substation type
Type 2
w/AVTB 20
up to 4 households
-

Supply
DHW
flow
Capacity
Primary
kW
C
34.7
60
47.1
60
45.1
70
65.6
70
-

Return
flow
Primary
C
24.4
26.8
21.3
23.8
-

Pressure
loss
Primary
kPa
20
45
20
45
-

Flow
rate
Secondary
l/h
744
1014
972
1410
-

* Capacity for 10 households at 70 C DH flow temperature

Gemina Termix A/S Member of the Danfoss Group Navervej 15-17 DK-7451 Sunds Denmark
Tel.: +45 9714 1444 Fax: +45 9714 1159 mail@termix.dk www.heating.danfoss.com

VC.LC.G4.02 Danfoss 05/2012

DEN-SMT/PL

Termix Novi
Instantaneous water heater for flats, single-family houses and small
apartment buildings with up to 4 flats.
Instantaneous water heater with heat exchanger and flow compensated temperature controller.
Designed for wall-mounting.
Application
The Termix Novi is an instantaneous water
heater featuring superb heat extraction
and high performance. The Termix Novi is
suitable for flats, single-family houses as
well as for small apartment buildings. The
water heater is available in two sizes, either
for 1 apartment, or up to 4 apartments. The
Termix Novi is applicable for decentralized
heating systems as well as for district heating networks with summer operation at low
temperatures or with changes in differential
pressure. The heat exchanger in Termix Novi
cools the district heating water very efficiently, thereby creating a very good operation economy.
Domestic hot water (DHW)
The domestic hot water is prepared in the
heat exchanger and the temperature is regulated by a flow-compensated temperature
controller with a integrated differential pressure controller. The Danfoss IHPT valve ensures a stable hot water temperature by

VL.GE.J3.02 Danfoss 05/2012

varying differential pressure without the


need for readjusting the valve. This protects
the heat exchanger against overheating and
lime scale formation. Furthermore the IHPT
valve has an integrated idle temperature
controller, which keeps the house supply
line warm. This shortens the waiting periods
during summer when the heating system is
in reduced operation, which is ideal where

Construction
All pipes are made of stainless steel. The connections are made by nuts and gaskets. The
Termix Novi is delivered with an attractive
grey full insulation in modern design, emphasising the high level of quality and comfort which characterises this product.

FEATURES AND BENEFITS


Instantaneous water heater

high comfort is requested.

DHW regulation with an accelerated


thermostatic control

Options
The water heater can be supplied with a built
in non-return valve and safety valve mounted in the cold water supply. The water heater
can also be supplied with a thermostatic circulation valve and a non-return and pressure
equalizer (GTU).

Capacity: up to 61 kW DHW
DHW in sufficient quantity
Operates independently of differential
pressure and flow temperature
Minimum space required for installation
Pipes and plate heat exchanger made of
stainless steel
Minimized risk of lime scale and bacteria
formation
Optimum temperature regulation up to
DH supply temperature 100 C

Termix Novi
Circuit diagram example

DH supply

DHW

B Water heater
9 Strainer
72 IHPT

72
9

CWM

DH return

Technical parameters:
Nominal pressure:
DH supply temperature:
DCW static pressure:
Brazing material (HEX):

Connections:
1 Domestic cold water (DCW)
2 Domestic hot water (DHW)
3 District heating flow (DH)
4 District heating return (DH)

PN 16
Tmax = 120 C
pmin = 1,0 bar
Copper

Weight incl. cover: 7 - 9 kg



(incl. packing)
Cover:
Grey lacquered steel

Wall

Connections sizes:
DH + DCW + DHW: G (ext. thread)
Options:
Booster pump (increases DH flow)
Grey-lacquered steel cover
Safety valve and non-return valve (10 bar)
Safety valve with thermostatic circulation set
Thermostatic circulation set
Non-return and pressure equalizer (GTU)

Dimensions (mm):
With insulation:
H 432 x W 300 x D 155
With cover:
H 442 x W 315 x D 165

DHW: Capacity examples


Substation
type

DHW
Capacity
kW

Supply
flow
Primary
C

Return
flow
Primary
C

DHW
C

Pressure
loss
Primary
kPa

DHW
Tap load
l/min

32,3
41,5
43
53
30
35
41
50

60
60
70
70
60
60
70
70

19
21
17
18
23
24
19
21

10/45
10/45
10/45
10/45
10/50
10/50
10/50
10/50

19
29
19
29
19
29
19
29

13,3
16,6
17,7
21,8
10,5
12,6
14,8
18,0

Technical data table

Novi Type 1

DHW: Capacity examples


Supply
DHW
Substation
flow
Capacity
type
Primary
kW
C

Novi Type 2

32,3
38
39
48,7
50
57
36
43
48
58,5

55
55
60
60
70
70
60
60
70
70

Return
flow
Primary
C

DHW
C

19
20
17
19
16
16
21
22
17
19

10/45
10/45
10/45
10/45
10/45
10/45
10/50
10/50
10/50
10/50

Pressure
DHW
loss
Tap load
Pr i m a r y
l/min
kPa
18
26
19
28
19
24
19
28
19
28

13,3
15,7
15,7
20,1
20,6
23,3
12,3
15,9
17,3
21,2

Gemina Termix A/S Member of the Danfoss Group Navervej 15-17 DK-7451 Sunds Denmark
Tel.: +45 9714 1444 Fax: +45 9714 1159 mail@termix.dk www.heating.danfoss.com

VL.GE.J3.02 Danfoss 05/2012

DEN-SMT-PL

Akva Vita II
Instantaneous water heater for single-family houses and flats
Pressure controlled instantaneous water heater with heat exchanger. Unique DHW temperature
control with esaveTM function and cold heat exchanger during standby.
Application
The Akva Vita II is an instantaneous water
heater featuring high performance and
simple operation. It is especially suitable for
single-family houses and for systems with a
similar domestic hot water requirement.
The Akva Vita II can be used directly on district heating networks with a differential
pressure of max. 2.5 bar.
Construction
The Akva Vita II water heater is prefabricated
with a brazed, highly efficient Danfoss plate heat exchanger for domestic hot water production, a domestic hot water controller Danfoss PM2+P, as well as a Danfoss
FJVR thermostat for control of the bypass/
circulation temperature. All pipes are made
of stainless steel and the connections are
made by nuts and gaskets. As an option and
if approved by local regulations the water
heater can be supplied with a Danfoss AVE
expansion unit to avoid having to establish
a discharge pipe.
Design
The Akva Vita II is designed for wallmounting and the design emphasizes a
user-friendly placement of the controllers.
The Akva Vita II can be supplied with a brushed or white-lacquered stainless steel cover
in an elegant and modern design.
Bypass (thermostatic circulation)
The water heater is supplied with a thermostatically controlled bypass, which ensuVL.GP.J1.02 Danfoss 10/2012

res that hot water is produced immediately, when tapping starts. The bypass temperature is set with due consideration of the best
possible DHW comfort and economy.
Domestic hot water circulation
The water heater is prepared for domestic
hot water circulation. If the household piping includes hot water recirculation the
water heater must be connected to the hot
water recirculation system and a circulation pump and a non-return valve must be
mounted on the circulation pipe and a safety valve must be mounted in the DCW inlet. The pump must be installed so that it
pumps towards the water heater. Domestic
hot water circulation ensures that hot water is available at the tapping point without
waiting time and waste of water. The circulation temperature is set independently of
the set DHW temperature. This ensures the
best possible DHW comfort, very low standby losses and thus a very good district heating economy. Please note that Akva Vita II
with AVE expansion unit should not be used
on systems with domestic hot water recirculation.
Heat exchanger for DHW heating
The water heater is based on a brazed, highly
efficient plate heat exchanger type XB 06H-1
26, which is controlled by a pressure controlled DHW controller, Danfoss PM+P with integrated differential pressure controller and
esaveTM function, which ensures that the
heat exchanger is cold during standby. Af-

ter completion of the tapping process, the


controller immediately blocks the district
heating flow, to avoid standby losses and
to protect the heat exchanger from the formation of lime scale and growth of bacteria.
The heat exchanger is cold during standby,
so the heat loss is very low. The integrated
differential pressure controller compensates
for variations in supply temperature and varying differential pressure and thereby ensures a constant hot water temperature at
all times.
Service and maintenance
The water heater is very service-friendly and
easy to install. It is mounted on the wall and
as all pipes are placed in pipe bracket distance, it is possible to establish a nice piping.

Features and benefits


COLD heat exchanger during standby, no standby losses
DHW controller PM2+P with integrated
differential pressure controller and esaveTM
function
Pipes and heat exchanger made of stainless steeel, connections with EPDM gaskets.
Minimized risk of lime scale and bacteria
formation, no Legionella
Capacity: 35 kW

Akva Vita II
Circuit diagram Example
1.

6 5

2. Domestic hot water controller type Danfoss


PM2+P.

3.

DHW circ.

5. Connection of capillary tube from Danfoss



FJVR acting as circulation thermostat (DHW
recirculation).

6.
DHW

Connection piece for circulation pipe, if any.

Note: Circulation set is not part of the delivery and must



be ordered separately and mounted on site.

DH.
return

Connections:
1. Domesctic cold water (DCW)
2. Domestic hot water (DHW)
3. District heating (DH) supply
4. District heating (DH) return
5. Circulation (not part of dly)

255

PN 16 / PN 16
120 C
pmin = 2.0 bar
See capacity examples
Max. 300 mg/l
9 kg

Cover:

Brushed steel

Dimensions (mm):
Without cover:
With cover:

H420xW250xD150
H420xW255xD160

55
420

Weight incl. cover:


(incl. packing)

200

391

Design specifications:
Nominal pressure (prim/sec.):
Max. supply temperature:
DCW static pressure:
Min. P:
Chloride compounds:

DH
Supply

60

Akva Vita II with heat


exchanger type:

80

60

(5)
1

XB 06H-1 26 + AVE

40

Connections sizes:
DH, DCW, DHW:
R ET (ext. thread)
Circulation: R ET (ext. thread))

Code Nos:

XB 06H-1 26

160

DCW

Bypass/circulation thermostat Danfoss FJVR.

4. Connection of capillary tube from Danfoss



FJVR acting as bypass thermostat (standard
function).

Bypass

Danfoss copper brazed plate heat exchanger


in stainless steel AISI 316, type XB 06H-1 26.

Top view

Cover:

Code no.:

w/o
brushed
brushed

004U8376
004U8378
004U8379

Options
Cover, brushed stainless steel H397xW225 x D160 mm
Circulation set for mounting on site
Safety valve set
AVE expansion unit*
* requires local approval

Varmt vand: Ydelseseksempler ved 10C / 45C


DHW
Capacity
kW
32.3
32.3
41.0
41.0

Supply flow
Primary
C
55
60
60
70

Return flow
Primary
C
21.8
18.9
20.4
16.8

DHW
tap load
l/min
13.16
13.16
16.96
16.86

Pressure loss*
Primary
bar
0.28
0.18
0.31
0.17

Flow rate
Primary
l/h
840
680
900
670

*) Stated pressure loss values are complete, incl. pipes, heat exchanger and valves.

Danfoss Redan A/S District Heating Omega 7 DK-8382 Hinnerup


Tel.: +45 87 43 89 43 Fax: +45 87 43 89 44 redan@danfoss.com www.redan.danfoss.dk

VL.GP.J1.02 Danfoss 10/2012

DKDHR

Akva Lux II GW
Instantaneous water heater for low-temperature district heating
Thermostatic and pressure controlled instantaneous water heater with heat exchanger. Unique DHW
temperature control with esaveTM function and cold heat exchanger during standby.
Application
Akva Lux II GW is an instantaneous water
heater featuring high performance. It meets
the future energy demands for low energy
consumption and very low standby heat losses. It is especially suitable for large villas with
for instance several bathrooms or jacuzzi and
for the large family, for which an exceptionally large amount of water is required. The Akva
Lux II GW is also very suitable for small apartment houses with 2-4 apartments.
Construction
The Akva Lux II GW water heater is prefabricated with a gasketed, highly efficient plate
heat exchanger for domestic hot water production, a domestic hot water controller Danfoss PTC2+P, as well as a Danfoss FJVR thermostat for control of the bypass/circulation
temperature. A circulation set, a safety set or,
if approved by local regulations, a Danfoss
AVE expansion unit to avoid having to establish a discharge pipe, is available as optional
equipment.
Design
The Akva Lux II GW is designed for wallmounting and the design emphasizes a userfriendly placement of the controllers. The
Akva Lux II GW can be supplied with a whitelacquered cover in modern design.
Bypass (thermostatic circulation)
The water heater is supplied with a thermostatically controlled bypass, which ensures
VL.GP.H1.02 Danfoss 10/2012

that hot water is produced immediately,


when tapping starts. The bypass temperature is set with due consideration of the best
possible DHW comfort and economy.
Domestic hot water recirculation
The water heater is prepared for domestic
hot water circulation. If the household piping includes hot water recirculation the
water heater must be connected to the hot
water recirculation system and aa circulation pump and a non-return valve must be
mounted on the circulation pipe and a safety valve must be mounted in the DCW inlet. The pump must be installed so that it
pumps towards the water heater. Domestic
hot water recirculation ensures that hot water is available at the tapping point without
waiting time and waste of water. The circulation temperature is set independently of
the set DHW temperature. This ensures the
best possible DHW comfort, very low standby losses and thus a very good district heating economy. Please note that Akva Lux II
with AVE expansion unit should not be used
on systems with domestic hot water recirculation.
Heat exchanger for DHW heating
The water heater is based on a highly efficient gasketed plate heat exchanger, which
is controlled by a thermostatic and pressure controlled DHW controller, Danfoss
PTC2+P with integrated differential pressure controller and esaveTM function, which ensures that the heat exchanger is cold during

standby. After completion of the tapping process, the controller immediately blocks the
district heating flow, to avoid standby losses
and to protect the heat exchanger from the
formation of lime scale and growth of bacteria. The heat exchanger is cold during standby, so the heat loss is very low. The integrated
differential pressure controller compensates
for variations in supply temperature and varying differential pressure and thereby ensures
a constant hot water temperature at all times.
Service and maintenance
The water heater is very service-friendly and
easy to install. It is mounted on the wall and
as all pipes are placed in pipe bracket distance, it is possible to establish a nice piping.

FEATURES AND BENEFITS


Prepared for low-temperature district heating
Very low heat losses
Cold heat exchanger during standby, - no
standby losses
DHW controller PTC2+P with integrated differential pressure controller and esaveTM function
Pipes and heat exchanger made of stainless
steel, connections with EPDM gaskets.
Minimized risk of lime scale and bacteria formation
Capacity: up to 53 kW DHW

Akva Lux II GW
Circuit diagram Example
1. Gasketed plate heat exchanger in stainless steel, type
U141RH
2. Domestic hot water controller Danfoss PTC2+P with esaveTM

function (= cold heat exchanger during standby).
3. By-pass/circulation thermostat Danfoss FJVR.
4. Connection of capillary tube from Danfoss FJVR acting as by-pass

(standard function).

6 5
DHW
circ.

---------------------------------------------------------------------------------Bypass

DHW circulation:

5. Connection of capillary tube from Danfoss FJVR acting as circulation


thermostat.
6. Connection of circulation hose. Circulation set for control

change from bypass to DHW recirculation is not part of the delivery and

must be ordered seperately.

DCW

DHW

Design specifications:
Nominal pressure (prim/sec.):
Max. supply temperature:
DCW static pressure:
Min. P:
Chloride compounds:
Weight incl. cover:
(incl. packing)

DH
Supply

DH
Return

PN 16 / PN 16
120 C
pmin = 2.0 bar
See capacity examples
Max. 300 mg/l

Connections:
1. Domesctic cold water (DCW)
2. Domestic hot water (DHW)
3. District heating (DH) supply
4. District heating (DH) return
5. Circulation (not part of dly)

17 kg

Code Nos:
Akva Lux II GW
water heater with
heat exchanger

Cover: White-lacquered
steel
Dimensions (mm):
Without cover:
With cover:

(Please note that AVE must not be used on systems with DHW circulation. For
systems with DHW recirculation the water heater must be supplied with circulation pump, non-return valve and safety valve mounted in the cold water
supply).

(5)

U141RH

H463xW280xD230
H463xW300xD240

Code no.:

w/o cover
w. cover

004U8366
004U8367

Options:
Cover H 430 x W 300 x D 240 mm
AVE pressure equalizer *
Circulation set for mounting on site
Safety valve set

Wall

Connections sizes:
DH, DCW, DHW:
G ET (ext. thread)
Circulation:
R ET (ext. thread)

Cover

(5)

* requires local approval

Top view

Varmt vand: Ydelseseksempler ved 10C/45C


DHW
Capacity
kW
32,3
32,3
41,0
53,0

Plate heat
exchanger
U141RH
U141RH
U141RH
U141RH

Supply flow
primary
C
55
60
60
60

Return flow
primary
C
22
18
20
22

DHW
tap load
l/min
13.16
13.16
16.86
21.84

Pressure loss*
Primary
bar
0.23
0.16
0.24
0.45

Flow rate
Primary
l/h
840
660
880
1200

*) Stated pressure loss values are complete, incl. pipes. heat exchanger and valves

Danfoss Redan A/S District Energy Omega 7 DK-8382 Hinnerup


Tel.: +45 87 43 89 43 Fax: +45 87 43 89 44 redan@danfoss.com www.redan.danfoss.dk

VL.GP.H1.02 Danfoss 10/2012

DKDHR

ThermoDual
Domestic hot water charging system for hospitals, hotels, restaurants,
sport centres as well as industrial buildings and dwelling houses
Domestic hot water charging system with heat exchanger
and optional self-acting or electronic controls
Application
ThermoDual is a compact and
effective domestic hot water (DHW)
charging system. It optimally
combines the system of storage
water heater and instantaneous water
heating system. The ThermoDual
system is suitable for hospitals,
hotels, restaurants, sport centres
as well as industrial buildings and
dwelling houses, where the constant
DHW temperature even during peak
consumption periods is needed.
ThermoDual can be supplied from
local and district heating systems,
low-temperature or condensing
boilers, boiler systems as well as solar,
process and waste heat systems. The
system is available in two different
types with integrated DHW storage
tank and integrated brazed (S) or
gasketed (GS) plate heat exchanger.
Domestic hot water (DHW)
The ThermoDual system can
be delivered with self-acting or
electronic controller for controlling

VL.KR.G3.02 Danfoss 12/2012

of the charging temperature and the


temperature in DHW storage tank.
It ensures the constant DHW flow
and temperature even during peak
consumption periods. The system
operates in three operation modes:
a load low operation, a peak load
operation and a charging operation
(no consumption).
Domestic hot water circulation
ThermoDual is supplied with
connection for DHW circulation. The
connection pipe of DHW circulation
is placed directly on the storage tank
or in the cold water side (between
storage tank and heat exchanger).
Options
The system can be combined with
a second or multiple DHW storage
tanks for optimum tailoring to on-site
conditions.
Construction
The DHW storage tank and plate
heat exchanger are made of stainless

steel. The ThermoDual system is


delivered as a set of DHW storage tank
and charging unit with all required
connection parts. The charging unit
can be easily assembled with DHW
storage tank through attached premounted fitting set.

FEATURES AND BENEFITS


DHW charging system
Electronic or self-acting control of DHW
temperature
Performance index NL: 3-87/11-871
Connected load: 22-150/25-150 kW1
Constant DHW temperature
Compact design
Easy installation
1

ThermoDualS/GS

ThermoDual
Circuit diagram - example

DTA Domestic buffer tank


HEL HEX charging/load
LPU Charging pump/load
SFV Safety valve
CVE Control valve electrical
(accessory)
CVS Control valve self-acting
(accessory)

shut off device


4

CVS/CVE

HEL TC
SFV
3

37

balancing valve

TC

sensor (direct, cable/universal, surface)


thermometer

DTA
LPU

Connections:

1
2
3
4
5
37

drain/air vent (on site/by customer)


3

Technical parameters:
Type S
Nominal pressure: PN 16 (25)2
DH supply temp.: Tmax = 100 (150)2 C
Type GS
Nominal pressure: PN 3
DH supply temp.: Tmax = 110 C

Options:
Stainless steel DHW storage tank, series
SE, capacity 100 ... 8000 liters
Tube and shell heat exchanger,
stainless steel, series SHRVAA
DHW-adequate bronze or stainless
steel charging pump
Balancing valve
Stainless steel sensor pockets

Domestic water cold


Domestic water hot
Circulation (options)
Heating supply
Heating return
Domestic water load

Self-acting control valves as 2-way


valve, 3-way mixing valve, or 3-way
diverting valve, with thread or ange
Control and safety thermostats, storage
tank thermometer
Additional storage tank

Available on request.

DHW: Capacity examples

Type

200-010
500-060
1000-060
300-030
-GS 500-020
1000-050
-S

DHW
temperatures
prim./sec.
C

70->25/10->60

65->35/10->60

Performance
index
NL3

8
72
87
35
30
87

Connected
load
kW

25
150
150
100
60
150

DHW top delivery

Dimensions
Input
W4

l/10 min

l/h

H
mm

W
mm

D
mm

388
1294
1973
817
925
1973

902
4373
5051
2864
2157
5051

1540
1765
2080
1705
1765
2080

800
1050
1150
1375
1450
1570

700
950
1250
975
1100
1200

max.87

Connections

Net
weight
kg
1, 2
68
103
169
150
173
244

11/2
2
11/2
2

3
3/4
1

4, 5
DN 20
(26,9mm)

3/4
G 11/4

Performance index NL acc. to DIN 4708 in relation to a storage tank water temperature of 60 C.
Charging pump; A.C. 1~230 V / 50 Hz; thermal motor overload protection or motor protection by integrated thermo switch.

3
4

Danfoss GmbH Fernwrme- und Regelungstechnik Kolumbusstrae 14 D-22113 Hamburg


Tel.: +49(0)40/736751-0 Fax: +49(0)69/8902466400 e-mail: info-hh@danfoss.com www.fernwaerme.danfoss.de

VL.KR.G3.02 Danfoss 12/2012

DEN-SMT/PL

Termix One-B with complete insulation


Instantaneous water heater for flats, single-family houses and small
apartment buildings with up to 4 flats
Instantaneous water heater with heat exchanger and thermostatic control.
Designed for wall-mounting.
Application
The Termix One is an instantaneous water
heater featuring superb heat extraction and
high performance. The Termix One is suitable for flats, single-family houses as well as
for small apartment buildings with up to 4
apartments. The water heater is available in
two sizes, either for 1 apartment or for 14
apartments. The Termix One is applicable
for decentralized heating systems as well
as for district heating networks with summer
operation at low temperatures or changes in
differential pressure. The Termix One heat exchanger cools the district heating water very
efficiently, thereby creating a very good operation economy.
Domestic hot water (DHW)
The domestic hot water is prepared in the
heat exchanger and the temperature is
regulated with a thermostatic control valve.
The patented sensor accelerator accelerates
the closing of the Danfoss AVTB valve and
protects the heat exchanger against over-

VL.IE.X1.02 Danfoss 01/2013

heating and lime scale formation. The sensor accelerator and AVTB valve also works
as a bypass keeping the house supply line
warm. This shortens the waiting periods during summer when the heating system is in
reduced operation. The sensor accelerator
helps to ensure a stable hot water temperature by varying loads, flow temperatures and
differential pressure without the need for
readjusting the valve. There is no additional
pressure loss on the secondary side of the
DHW heat exchanger with a thermostatic
control. Therefore this type of regulation can
be used by low pressure on the in the cold
water mains.
Construction
All pipes are made of stainless steel. The connections are made by nuts and gaskets. The
Termix One comes with a complete fully insulated cover thus minimizing the heat loss
both during tapping of domestic hot water
but also in standby mode.

FEATURES AND BENEFITS


Instantaneous water heater
DHW regulation with an accelerated
thermostatic control
Capacity: up to 65 kW on DHW
DHW in sufficient quantity
Operates independently of differential
pressure and flow temperature
Minimum space required for installation
Pipes and plate heat exchanger made
of stainless steel
Minimized risk of lime scale and
bacteria formation
Low heat loss

Termix One-B with complete insulation


Circuit diagram - example
Termix One-B with complete insulation
B Plate heat exchanger DHW
7 Thermostatic valve

DH
supply

DHW

DH
return

DCW

Technical parameters:
Nominal pressure:
DH supply temperature:
DCW static pressure:
Brazing material (HEX):

PN 16
Tmax = 120 C
pmin = 0,5 bar
Copper

Weight:
10 - 12 kg
(incl. packing)

Connections sizes:
DH + DCW + DHW:

G (ext. thread)

Connections:
1 Domestic cold water (DCW)
2 Domestic hot water (DHW)
3 District heating (DH) supply
4 District heating (DH) return

Dimensions (mm):
H 435 x W 355 x D 195 (type 1+2)

Options:
Booster pump (increases DH flow)
Safety valve and non-return valve (10
bar)
Safety valve with thermostatic circulation set
Thermostatic circulation set
Non-return and pressure equalizer
(GTU)

Wall

Seen from above

DHW: Capacity examples, 10C/50C


Substation type

DHW
Capacity
kW

Type 1
w/AVTB 15
1 household

29.3
38.2
37.8
52.3

Supply
flow
Primary
C
60
60
70
70

Return
flow
Primary
C
23.0
25.2
20.0
22.4

Pressure
loss
Primary
kPa
20
45
20
45

Flow
rate
Secondary
l/h
630
822
816
1128

Substation type
Type 2
w/AVTB 20
up to 4 households

Supply
DHW
flow
Capacity
Primary
kW
C
34.7
60
47.1
60
45.1
70
65.6
70

Return
flow
Primary
C
24.4
26.8
21.3
23.8

Pressure
loss
Primary
kPa
20
45
20
45

Flow
rate
Secondary
l/h
744
1014
972
1410

Gemina Termix A/S Member of the Danfoss Group Navervej 15-17 DK-7451 Sunds Denmark
Tel.: +45 9714 1444 Fax: +45 9714 1159 mail@termix.dk www.heating.danfoss.com

VL.IE.X1.02 Danfoss 01/2013

DEN-SMT/PL

Data sheet

ThermoDual
Domestic hot water charging system

Description/Application

ThermoDual is the compact and effective


domestic hot water (DHW) charging system.
Due to the consistent use of carefully selected
components and highest quality materials, the
compact the ThermoDual system meet all of
the requirements for the prevention of legionella
growth.
The highly efficient heat transfer of the heat
exchangers enable The ThermoDual system to
attain low heating water return temperatures
across the entire cycle of a tank charge, thus
reducing the required media flows. This
translates into greater operational efficiency and
predestines this system for utilization in district
heating networks and in combination with
condensing boilers. The optimum adaptation to
the applicable specific needs in terms of storage
capacity and output ensures a maximum of
efficiency, comfort and hygiene.
Main system data
Primary
Type
Max. operating temp. (C)
Max. operating pressure (bar)
Working medium

S
150
25

Approvals and Standards:


- W 553 of the DVGW2 working temperature /
circulation,
- W 551 of the DVGW2 prevention of legionella
growth,

ThermoDual-S
Compact DHW charging system with stainless
steel domestic hot water storage tank and
brazed plate heat exchanger as well as
pre-installed piping assembly with allrequired
fittings for installation.

DEN-SMT/PL

VD.KR.C4.02 Danfoss 12/2013

GS
110
3
Circulation water/DHW

Secondary
90
10

- DIN4753DHW storage tank.


German Technical and Scientific Association
for Gas and Water

ThermoDual-GS
Compact DHW charging system with stainless
steel domestic hot water storage tank and
gasketed plate heat exchanger as well as
pre-installed piping assembly with all required
fittings for installation.

Data sheet

ThermoDual DHW charging system

Ordering

Explanation, ThermoDual types


ThermoDual- S 200-010

Numbers for plates for heatexchanger

Volume storage tank (liter)
Type

S with brazed plate heat exchanger

GS with gasketed plate heat exchanger

DHW charging system with pre-installed pipes assembly with all required
fittings for installation

ThermoDual-S (brazed plate heat exchanger)


Type
S 100-020 VA
S 100-036 VA
S 200-010
S 200-016
S 200-026
S 200-030
S 300-010
S 300-016
S 300-026
S 300-030
S 300-040
S 300-050
S 350-010
S 350-016
S 350-026
S 350-030
S 350-040
S 350-050
S 500-010
S 500-016
S 500-026
S 500-030
S 500-040
S 500-050
S 500-060
S 750-016
S 750-026
S 750-030
S 750-040
S 750-050
S 750-060
S 1000-026
S 1000-030
S 1000-040
S 1000-050
S 1000-060

VD.KR.C4.02 Danfoss 12/2013

Code No.
004F7468
004F7469
004U1700
004U1701
004U1702
004U1703
004U1707
004U1708
004U1709
004U1710
004U1711
004U1712
004U1714
004U1715
004U1716
004U1717
004U1718
004U1719
004U1721
004U1722
004U1723
004U1724
004U1725
004U1726
004U1727
004U1729
004U1730
004U1731
004U1732
004U1733
004U1734
004U1737
004U1738
004U1739
004U1740
004U1741

ThermoDual-GS (gasketed plate heat exchanger)


Type
GS 300-020
GS 300-030
GS 350-020
GS 350-030
GS 500-020
GS 500-030
GS 500-040
GS 500-050
GS 750-020
GS 750-030
GS 750-040
GS 750-050
GS 1000-020
GS 1000-030
GS 1000-040
GS 1000-050

Code No.
004U1743
004U1744
004U1748
004U1749
004U1753
004U1754
004U1755
004U1756
004U1758
004U1759
004U1760
004U1761
004U1763
004U1764
004U1765
004U1766

DEN-SMT/PL

Data sheet

ThermoDual DHW charging system


Main components
Main components in standard system:
- DHW-approved charging pumps,4
- Storage tank,
- Heat exchanger,
- Shut-off valve,5
- Balancing valve,
- Safety valve,
- Thermometer.5

Accessories

200 ... 1000l high efficiency pump (EEL<=0,23)


100l
- without
200l - 2 thermometers, 2 valves
4

The ThermoDual system can be combined


with a second multiple DHW storage tanks for
optimum tailoring to on-site conditions:

For controlling DHW temperature self acting or


electronical controllers can be used:

- Stainless steel domestic hot water storage


tank, series SE, capacity 200 8000 liters
(assembling/pipes by customer)

- self acting controllers VG/AVT/(STM)


- electronical controller ECL 110/210/310
(assembling by customer)

To connect circulation, system can be combined


with pre-mounted circulation groups:

- other accessories see local pricelist

Type

Code

Vpc min

dp

Vpc max

dp

[l/min]

[kPa]

[l/min]

[kPa]

connection

lenght L

weight

[mm]

[kg]

3a

3b

R1"

R1

544

5,3

TD-Z 25-25-I

004U1624

80

20

70

TD-Z 25-25-II

004U1625

10

80

40

40

R1

R1

544

5,3

TD-Z 25-32-I

004U1626

20

70

60

15

R1

R1

535

5,5

Vpc- min minimal selectable flow for circulation


Vpc- max maximal selectable flow for circulation
dp - rest pressure available by Vpc

DEN-SMT/PL

VD.KR.C4.02 Danfoss 12/2013

Data sheet

ThermoDual DHW charging system

Technical data

[l/10
min]

10 -> 45 C
[l/h]

10 -> 60 C
[l/h]

Heating
water
flow
[l/h]

Pressure
loss
HEX
[kPa]

380

542

759

1083

431

479

13

690

766

11

1034

1149

1379

1532

11

616

431

479

13

986

690

766

11

1906

1477

1034

1149

757

2399

1970

1379

1532

11

100

839

2892

2463

1724

1915

10

130

962

3630

3201

2241

2489

11

12

25

603

1116

616

431

479

13

350-016

18

40

664

1486

986

690

766

11

350-026

26

60

746

1977

1477

1034

1149

350-030

34

80

828

2470

1970

1379

1532

11

350-040

39

100

910

2963

2463

1724

1915

10

350-050

48

130

1033

3701

3201

2241

2489

11

500-010

15

25

817

1330

616

431

479

13

21

40

879

1700

986

690

766

11

500-026

30

60

960

2191

1477

1034

1149

500-030

39

80

1043

2684

1970

1379

1532

11

500-040

48

100

1125

3177

2463

1724

1915

10

500-050

63

130

1248

3915

3201

2241

2489

11

500-060

72

150

1330

4407

3693

2585

2872

10

750-016

27

40

1236

2057

986

690

766

11

750-026

36

60

1318

2548

1477

1034

1149

750-030

45

80

1400

3041

1970

1379

1532

11

750-040

55

100

1482

3534

2463

1724

1915

10

750-050

70

130

1605

4272

3201

2241

2489

11

750-060

80

150

1687

4764

3693

2585

2872

10

1000-026

43

60

1675

2906

1477

1034

1149

1000-030

52

80

1757

3399

1970

1379

1532

11

1000-040

62

100

1839

3892

2463

1724

1915

10

1000-050

77

130

1962

4630

3201

2241

2489

11

1000-060

87

150

2044

5122

3693

2585

2872

10

300-020

23

60

675

1906

1477

1034

1550

14

300-030

35

100

839

2892

2463

1724

2605

16

350-020

26

60

746

1977

1477

1034

1550

14

350-030

40

100

910

2963

2463

1724

2605

16

500-020

30

60

960

2191

1477

1034

1550

14

500-030

48

100

1125

3177

2463

1724

2605

16

500-040

63

130

1248

3915

3201

2241

3328

15

500-050

72

150

1330

4407

3693

2585

3738

12

36

60

1318

2548

1477

1034

1550

14

750-030

55

100

1482

3534

2463

1724

2605

16

750-040

70

130

1605

4272

3201

2241

3328

15

750-050

80

150

1687

4764

3693

2585

3378

12

1000-020

43

60

1675

2906

1477

1034

1550

14

1000-030

62

100

1839

3892

2463

1724

2605

16

1000-040

77

130

1962

4630

3201

2241

3328

15

3738

12

Connected
load [kW]

22

233

686

543

44

324

1227

1084

200-010

25

388

902

616

200-016

11

40

450

1272

986

200-026

15

60

532

1763

1477

200-030

20

80

614

2256

1970

300-010

11

25

531

1045

300-016

17

40

593

1415

300-026

23

60

675

300-030

29

80

300-040

35

300-050

43

350-010

100-020
100-036

500-016

-GS

DHW pemanent delivery


performance

Performance
index NL*

Type

-S

DHW top delivery


performance
10 -> 45 C

750-020

DHW
temperatures
prim./sec. [C]
70->35/10->60

70->25/10->60

65->35/10->60

[l/h]

1000-050
87
150
2044
5122
3693
2585
* Performance index l NL acc. to DIN 4708 in relation to a storage tank water temperature of 60 C
** Charging pump; A.C. 1 ~ 230 V / 50 Hz; thermal motor overload protection or motor protection by integrated thermo switch

VD.KR.C4.02 Danfoss 12/2013

Input
[W]**

max.87

DEN-SMT/PL

Data sheet

ThermoDual DHW charging system

Design and function


shut off device
4

CVS/CVE

HEL TC
SFV
3

37

balancing valve

TC

sensor (direct, cable/universal, surface)


thermometer

DTA
LPU

drain/air vent (on site/by customer)


3

Connections:
1 Domestic water cold
2 Domestic water hot
3 Circulation (options)
4 Heating supply
5 Heating return
37 Domestic water load

Components:
DTA Domestic buffer tank
HEL HEX charging/load
LPU Charging pump/load
SFV Safety valve
CVE Control valve electrical (accessory)
CVS Control valve self-acting (accessory)

The domestic hot water flow pumped through


the heat exchanger (HEL) by the charging pump
(LPU) remains constant at all times and is preset
via the balancing valve.

The domestic hot water temperature is


maintained at a constant level through a
balancing valve via the water temperature
controller (CVS/CVE).
As a result, the following operation modes can
be defined for the ThermoDual DHW charging
system:
Low Load Operation
During low load operation, all of the cold water
flows through the heat exchanger (HEL). If the
tap output is smaller than the flow pre-set by the
balancing valve, a portion of the hot water (tap
flow) flows to the tap locations in the upper part
of the tank (DTA) as a bypass. The residual water
is removed from the bottom of the tank (DTA),
causing the tank (DTA) to be continually charged.
The total tap output is covered by the heat
exchanger (HEL), while the storage tank (DTA) is
not being discharged.
Peak Load Operation
During peak load operation (higher demand that
can be supplied by the available heating power),
the pre-set cold water flow flows through the
heat exchanger (HEL) and the residual water
streams from the bottom to the top of the
storage tank (DTA). The tap output is covered
by the heat exchanger (HEL) while the domestic
water storage tank (DTA) is being simultaneously
discharged.
Once tap operation ceases, the storage tank
(DTA) is charged as described below.

DEN-SMT/PL

VD.KR.C4.02 Danfoss 12/2013

Data sheet

ThermoDual DHW charging system


Charging Operation (no consumption)
If there is no consumption the storage tank (DTA)
is being charged.
The total charging flow is removed through
the bottom of the tank (DTA) and returned
through the top of the storage tank (DTA) via
heat exchanger (HEL). If the storage tank (DTA) is
completely charged and no output consumption
occurs, the control valve (CVS/CVE) closes and
interrupts the heating water flow.
A virtual flash showing the operations is
available, please contact your Danfoss local
representative.

VD.KR.C4.02 Danfoss 12/2013

DEN-SMT/PL

Data sheet

ThermoDual DHW charging system

Sizing

Dimensioning and selection of the ThermoDual


system should be carried out with the support of
the Danfoss dimensioning program.

Dimensioning Diagram for Dwelling Houses acc. to DIN 4708

Example:
Performance index:.......... NL 60
Selected:
Storage tank capacity:..... 750 liters

DEN-SMT/PL

VD.KR.C4.02 Danfoss 12/2013

Evaluated:
Power consumption:........ 110 kW

Data sheet

ThermoDual DHW charging system

Mounting

ThermoDual-S
After the storage tank has been set up, the heat
exchanger is attached. The pre-mounted fitting
set, charging pump and stainless steel pipe can
be easily installed due to mainly flat screw-top
connections. The blow-off pipe of the safety
valve is to be installed by the customer, based on
local conditions and requirements.

ThermoDual-GS
Connect the storage tank and the heat
exchanger with the pre-mounted piping set,
fitting sets and charging pump.
The blow-off pipe of the safety valve is to
be installed by the customer, based on local
conditions and requirements.

Dimensions

ThermoDual-S-100

ThermoDual-GS
05

01

04

02

02

03

04

05

01

ThermoDual-S 2001000

VD.KR.C4.02 Danfoss 12/2013

DEN-SMT/PL

Data sheet

ThermoDual DHW charging system

Type

-S

-GS

100-020
100-036
200-010
200-016
200-026
200-030
300-010
300-016
300-026
300-030
300-040
300-050
350-010
350-016
350-026
350-030
350-040
350-050
500-010
500-016
500-026
500-030
500-040
500-050
500-060
750-016
750-026
750-030
750-040
750-050
750-060
1000-026
1000-030
1000-040
1000-050
1000-060
300-010
300-020
300-030
350-010
350-020
350-030
500-010
500-020
500-030
500-040
500-050
750-020
750-030
750-040
750-050
1000-020
1000-030
1000-040
1000-050

connections

[mm]

[mm]

approx.9
[mm]

approx.9
[mm]
670
730

1290

610

575

1540

590

760

835

1705

640

860

885

1725

690

895

935

1,2
Rp

3
Rp

4,5
DN/G

"

20/257

1765

790

895

1035

2080

890

1020

1135

1"

2"
2080

990

1105

1255

1705

640

1270

920

1725

690

1295

970

1765

790

1345

1070

2080

890

1395

1155

18
1
2

2080

1030

1465

1275

weight6
[kg]
40
45
68
69
70
71
72
73
74
75
77
79
79
80
81
82
84
86
93
94
95
96
98
100
103
140
141
142
144
146
149
161
162
164
166
169
140
145
150
146
151
156
168
173
178
181
184
191
195
199
202
223
237
241
244

Tare weight without water


Welding tails 26,5 2,3mm (up tp 130kW) / 150kW: - 33,7 2,6mm)
External thread acc. ISO 228/1
9
Tolerance: +/-10 mm
6
7
8

DEN-SMT/PL

VD.KR.C4.02 Danfoss 12/2013

Data sheet

ThermoDual DHW charging system

10

VD.KR.C4.02 Danfoss 12/2013

DEN-SMT/PL

Akva Therm II LV
Domestic hot water charging system for hospitals, restaurants,
sporting centres as well as commercial buildings and apartment blocks
Domestic hot water charging system. Can be supplied directly from district heating supply networks, from
low-temperature or condensing boilers, solar-, process- or waste heat systems.
Application
The Akva Therm II LV is a compact and
effective domestic hot water (DHW)
charging system.
It optimally combines the two systems,
storage water heating and instantaneous water heating and is applicable
for hospitals restaurants, sport centres
as well as commercial buildings and
apartment blocks, where a constant
DHW temperature even during peak
consumption periods is needed.
The Akva Therm II LV can be supplied
from district heating supply networks,
from low-temperature or condensing
boilers, solar-, process- and waste heat
systems.
Domestic hot water
The Akva Therm II LV charging system is
delivered as a set consisting of a stainless steel DHW cylinder, a brazed, stainless steel plate heat exchanger, Danfoss
XB37H-1, Danfoss ECL 310 for control of
the charging temperature and temperature in the DHW cylinder, Wilo low-energy circulation pump, shut-off valves,
balancing valves / flow limiter, safety
valves, thermometers as well as readyto-mount pipes and fittings.

VL.GE.F2.02 Danfoss 11/2013

Domestic hot water circulation


The Akva Therm II LV charging system
is supplied with connection for DHW
circulation. The DHW circulation pipe
connection is placed directly on the cylinder.
Design
A total of 24 standard applications are
available in the LV series, however, the
possibilities are many, as the heat exchanger size and cylinder volume can
be combined according to requirement.
The capacities of the heat exchangers range from 25 and 110 kW and the
tanks are available in sizes from 350 to
1000 liters. The standard executions
supplies 12 to 69 apartments. For other
sizes, please contact our sales department.

system the system is optimized in order


to achieve higher efficiency and better
cooling. The LV unit is characterized by a
good stratification in the cylinder. Circulation is connected to the cylinder center and the return does not affect the
stratification of the system. The electronic control and stratification ensures excellent operating economy.
Serviceability and ease of assembly
The charging unit can easily be mounted and serviced, as all parts are assembled with nuts and gaskets.

FEATURES & BENEFITS


Charging system for domestic hot water
Can be supplied from district heating
supply networks, from low-temperature
or condensing boilers, solar, process and
waste heat systems

Long life
The use of acid-resistant, stainless steel for pipes, tank and heat exchanger,
and dezincification-resistant brass for Tpieces, components and valves, as well
as approved components secures the
charging system a long life.

Available in standard executions for supply of 12-69 apartments

Good operating economy,


By using Danfoss automatics for the
control of the Akva Therm II LV charging

Pipes, cylinder and heat exchanger made


of stainless steel

Electronic control - excellent operating


economy

Akva Therm II LV
Circuit diagram - example

DH
Supply

2. Brazed plate heat exchanger,


stainless steel AISI 316
7. Ball valve
9. Charging pump
12. Safety valve DHW 10 bar
13. Thermometer
17. Air valve
20. Balancing valve
25. Domestic hot water control
ECL 310, app. 217
28. Sensor
31. Actuator 1
32. Valve 1
37. Fully insulated storage tank, stainless
steel

DHW

Circ.
DH
Return

Supply limit
DCW

LV20-500
LV36-750
LV50-1000

Dimensions, tank:
LV16-350:
LV20-500:
LV36-750:
LV50-1000:

H 1750 x D 720 mm
H 1890 x D 720 mm
H 2130 x D 920 mm
H 2180 x D 1060 mm

340

128
571

79 kg
95 kg
145 kg
169 kg

350 L: 1750
500 L: 1890
750 L: 2130
1000 L: 2180

Weight incl. packing: LV16-350

300

155

Technical parameters:
Nominal pressure:
PN 16 / PN 10
Max. temperature: 95 C (construction temp.)
Min. P:
See capacity examples

3 5
1000 L: Dia.1060
750 L: Dia.920
350 - 500 L: Dia.720

Connections:
1. District heating (DH) supply
2. District heating (DH) return
3. Domestic cold water (DCW)
4. Domestic hot water (DHW)
5. Circulation (optional)
6. Circulation
Connections (examples):
LV16-350:
DCW,DHW 1
LV20-500:
DCW,DHW 1
LV36-750:
DCW,DHW 2
LV50-1000:
DCW,DHW 2

DH., Circ.
DH ., Circ. 1
DH., Circ. 1
DH., Circ. 1

200

DHW: Capacity examples 60/15 - 10C / 50C

Akva Therm II
LV Type
LV16-350
LV20-350
LV20-500
LV36-350
LV36-500
LV36-750
LV50-500
LV50-750
LV36-750

Tank
volume
350
350
500
350
500
750
500
750
1000

No. of
apartments.
(guiding)*
15
18
22
36
41
47
58
63
69

Heat
exchanger
(kW)
25
40
40
80
80
80
110
110
110

Capacity
Constant,
Max. capacity
DHW
(l/h)
(l/h)
537
800
860
1123
860
1235
1720
1983
1720
2095
1720
2283
2365
2740
2365
2928
2365
3115

Primary
Max. capacity
l/10 min.)

Pressure loss
bar

Flow
(l/h)

352
406
518
549
662
849
769
957
1144

0.19
0.19
0.19
0.25
0.25
0.25
0.21
0.21
0.21

478
764
764
1529
1529
1529
2102
2102
2102

Danfoss Redan A/S District Heating Omega 7 DK-8382 Hinnerup


Tel.: +45 87 43 89 43 Fax: +45 87 43 89 44 redan@danfoss.com www.redan.danfoss.dk

VL.GE.F2.02 Danfoss 11/2013

DKDHR

MAKING MODERN LIVING POSSIBLE

Termix One-B
Instantaneous water heater for flats, single-family houses
and small apartment buildings with up to 10 flats
Instantaneous water heater with heat exchanger
and thermostatic control. Designed for wallmounting.

Application
The Termix One is an instantaneous
water heater featuring superb heat
extraction and high performance.
The Termix One is suitable for flats,
single-family houses as well as for
small apartment buildings with up
to 10 apartments. The water heater
is available in three sizes, either for
1 apartment, for 14 apartments or
for 5 up to 10 apartments. The Termix
One is applicable for decentralized
heating systems as well as for district heating networks with summer
operation at low temperatures or
changes in differential pressure. The
Termix One heat exchanger cools the
district heating water very efficiently,
thereby creating a very good operation economy.
Domestic hot water (DHW)
The domestic hot water is prepared in
the heat exchanger and the temperature is regulated with a thermostatic
control valve. The patented sensor accelerator accelerates the closing of the
Danfoss AVTB valve and protects the
heat exchanger against overheating
and lime scale formation. The sensor accelerator and AVTB valve also works as
a bypass keeping the house supply line

districtenergy.danfoss.com

warm. This shortens the waiting periods


during summer when the heating system is in reduced operation. The sensor
accelerator helps to ensure a stable hot
water temperature by varying loads,
flow temperatures and differential pressure without the need for readjusting
the valve. There is no additional pressure loss on the secondary side of the
DHW heat exchanger with a thermostatic control. Therefore this type of
regulation can be used by low pressure
on the in the cold water mains.
Options
The water heater can be supplied
with a (built-in) in non-return valve
and safety valve mounted in the cold
water supply. The water hater can
also be supplied with a thermostatic
circulation valve and a non-return
and pressure equalizer (GTU).
Construction
All pipes are made of stainless steel. The
connections are made by nuts and gaskets. The Termix One is delivered with
an attractive steel grey cover in modern
design, emphasising the high level of
quality and comfort which characterises
this product.

FEATURES AND BENEFITS

Instantaneous water heater


DHW regulation with an
accelerated thermostatic control
Capacity: up to 90 kW on DHW
Capacity: 15kW HE, 55kW TWW
DHW in sufficient quantity
Operates independently of differential
pressure and flow temperature
Minimum space required
for installation
Pipes and plate heat exchanger
made of stainless steel
Minimized risk of lime scale
and bacteria formation

Termix One-B
Circuit diagram example

DH
Supply

DHW

Termix One with GTU


B
7
21
62

21
7

DH
Return

62

DCW

DH
Supply

Termix One with safety valve

DHW
21
6

B
2
4
6
7
21

Circ.

DH
Return

DCW

Technical parameters:
Nominal pressure:
DH supply temperature:
DCW static pressure:
Brazing material (HEX):

PN16
Tmax = 120C
Pmin = 0.5bar
Copper

Weight incl. cover:


1012kg
(incl. packing)

Connections:
1. Domestic cold water (DCW)
2. Domestic hot water (DHW)
3. District Heating (DH) supply
4. District heating (DH) return

Plate heat exchanger DHW


Non-return valve
Safety valve
Thermostatic/non-return valve
Thermostatic valve
Thermostatic valve

Connections sizes:
DH + DCW + DHW:

wall

Cover:
Grey-lacquered steel
Dimensions (mm):
Without cover:
H428 W312 D155
H468 W312 D155
With cover:
H430 W315 D165
H470 W315 D165

Plate heat exchanger DHW


Thermostatic valve
To be ordered separately
GTU pressure equalizer

G (ext. thread)

Options:
Booster pump (increases DH flow)
Grey-lacquered steel cover
Safety valve and
non-return valvve (10bar)
Safety valve with
thermostatic circulation set
Pressure equalizer (GTU)

(type 1+2)
(type 3)
(type 1+2)
(type 3)

DHW: Capacity examples, 10C / 50C


Substation
type

Type 1
w/AVTB 15
1 household
Type 3
w/AVTB 20
5 to 10* households

DHW
capacity
[kW]

Supply
flow
primary
[C]

Return
flow
primary
[C]

Pressure
Flow
loss
rate
primary secondary
[kPa]
[l/h]

29.3
38.2
37.8
52.3
60

60
60
70
70
60

23.0
25.2
20.0
22.4
23.0

20
45
20
45
35

630
822
816
1128
1280

66

60

24.0

45

1426

80
90

70
70

20.3
21.0

35
45

1730
1940

DHW
capacity
[kW]

Supply
flow
primary
[C]

Return
flow
primary
[C]

34.7
47.1
45.1
65.6

60
60
70
70

24.4
26.8
21.3
23.8

20
45
20
45

744
1014
972
1410

Substation
type

Type 2
w/AVTB 20
up to 4 households

Pressure
Flow
loss
rate
primary secondary
[kPa]
[l/h]

* Capacity for 10 households at 70 C DH flow temperature

Gemina Termix A/S Member of the Danfoss Group Navervej 15-17 DK-7451 Sunds Denmark
Tel.: +45 9714 1444 Fax: +45 9714 1159 mail@termix.dk www.heating.danfoss.com

VC.LA.Z3.02 Danfoss 01/2014

DENSMT/PL

MAKING MODERN LIVING POSSIBLE

Akva Lux II
Fully insulated instantaneous water heater for low-temperature
district heating
Thermostatic and pressure controlled instantaneous water heater
with heat exchanger. Unique DHW temperature control with energy
saving function and cold heat exchanger during standby.
Application
Akva Lux II is a fully insulated instantaneous water heater featuring high performance. It meets the future energy demands for low energy consumption and
very low standby heat losses. It is especially suitable for large villas with for instance several bathrooms or jacuzzi and
for the large family, for which an exceptionally large amount of water is required. The Akva Lux II is also very suiable for small apartment houses with
2-4 apartments.
Construction
The Akva Lux II water heater is prefabricated with a brazed, highly efficient
Danfoss plate heat exchanger for domestic hot water production, a domestic
hot water controller Danfoss PTC2+P,
as well as a Danfoss FJVR thermostat for
control of the bypass/circulation temperature. A circulation set and a safety set
is available as optional equipment.
Design
The Akva Lux II is designed for wallmounting and much importance has
been assigned to a user-friendly and
easily accessible placement of all system
components, including the controllers.
The Akva Lux II is fully insulated in an
EPP insulation box and can be supplied
with a white-lacquered cover in modern
design.
Bypass (thermostatic circulation)
The water heater is supplied with a thermostatically controlled bypass, which
ensures that hot water is produced immediately, when tapping starts. The by-

districtenergy.danfoss.com

pass temperature is set with due consideration of the best possible DHW comfort and economy.
Domestic hot water recirculation
The water heater is prepared for domestic hot water circulation. If the household piping includes hot water recirculation the water heater must be connected to the hot water recirculation
system and a circulation pump and a
non-return valve must be mounted on
the circulation pipe and a safety valve
must be mounted in the DCW inlet. The
pump must be installed so that it pumps
towards the water heater. Domestic hot
water recirculation ensures that hot water is available at the tapping point without waiting time and waste of water.
The circulation temperature is set independently of the set DHW temperature. This ensures the best possible DHW
comfort, very low standby losses and
thus a very good district heating economy.
Heat exchanger for DHW heating
The water heater is based on a brazed, highly efficient plate heat exchanger type XB 06H-1 26 or XB 06H-1 40,
which is controlled by a thermostatic
and pressure controlled DHW controller, Danfoss PTC2+P with integrated differential pressure controller and energy
saving function, which ensures that the
heat exchanger is cold during standby.
After completion of the tapping process,
the controller immediately blocks the district heating flow, to avoid standby losses and to protect the heat exchanger
from the formation of lime scale and

FeATURES AND BENEFITS

Prepared for low-temperature


district heating
Fully insulated and very
low heat losses
Cold heat exchanger during
standby, - no standby losses
DHW controller PTC2+P with
integrated differential pressure
controller and energy saving function
Pipes and heat exchanger made
of stainless steel, connections
with EPDM gaskets.
Minimized risk of lime scale
and bacteria formation
Capacity: up to 53 kW DHW

growth of bacteria. The heat exchanger


is cold during standby, so the heat loss
is very low. The integrated differential
pressure controller compensates for variations in supply temperature and varying differential pressure and thereby ensures a constant hot water temperature
at all times.
Service and maintenance
The water heater is very service-friendly
and easy to install. It is mounted on the
wall and as all pipes are placed in pipe
bracket distance, it is possible to establish a nice piping.

Akva Lux II
Circuit diagram example
2. Danfoss, copper brazed plate heat exchanger in stainless

steel AISI 316, type XB 06H-1 26 or XB 06H-1 40.
38. Domestic hot water controller Danfoss PTC2+P with energy saving

function (= cold heat exchanger during standby).
40. By-pass/circulation thermostat Danfoss FJVR.
----------------------------------------------------------------------------------

38

C B
DHW
circ.

DHW circulation:
A. Connection of capillary tube from Danfoss FJVR acting as by-pass

(standard function).
B. Connection of capillary tube from Danfoss FJVR acting as circulation
thermostat.
C. Connection of circulation hose. Circulation set for control
2 change from bypass
to DHW recirculation
is not part of5 the delivery and
3
4

must be ordered seperately.

40

A
A

For
systems with DHW
recirculation the 4water heater must 5be supplied with
3
2
circulation
pump, non-return valve and safety valve mounted in the cold
200
water supply.

Weight excl. cover:



XB06H-1 40 = 9kg

PN16 / PN16
120C
pmin = 2.0bar
See capacity examples B
Copper

DH
return

XB06H-1 26 = 8kg

Insulation:
EPP 0.039

200

Code Nos:
Akva Lux II water
heater with heat
exchanger type:

Cover:
White-lacquered steel
D

H 463 W 306 D 190


H 463 W 310 D 210
G ET (ext. thread)
R ET (ext. thread)

306
80

60

306
(5)
80

XB 06H-1 40
60

(w/o white cover)

XB 06H-1 26
XB 06H-1 26
XB 06H-1 40
XB 06H-1 40
XB 06H-1 26
XB 06H-1 26
XB 06H-1 40
XB 06H-1 40

Supply
flow
F
primary
[C]
1
F 55
60
1
55
60
60
70
60
70

w/o cover
w. cover
w/o cover
w. cover

004U8243
004U8245
004U8244
004U8246

Projection

General tolerance accuracy

Replace
Projection

General tolerance accuracy


Design

Return flow
primary
[C]
2
21.8
18.9
2
19.0
17.0
20.4
16.8
19.1
15.7

DHW
tap load
[l/min]
3
13.16
13.16
3
13.16
13.16
16.86
16.86
21.84
21.84

Pressure loss*
primary
[bar]
4
0.28
0.18
4
0.19
0.13
0.31
0.17
0.39
0.25

Approval
Weight
Replace

Flow rate
primary
[l/h]
840
680
770
650
900
670
1127
850

kg

Scale

1:5

Danfoss Re

Confidential: Property of Danfoss Redan A/S, Nordborg, Denmark.

Design
Not to be handed over to, copied or used by third party. Two- or three

dimensional reproduction of contents to be authorized by Danfoss Redan A/S.

Approval

Danfoss Red

Confidential: Property of Danfoss Redan A/S, Nordborg, Denmark.


Not to be handed over to, copied or used by third party. Two- or three
dimensional reproduction of contents to be authorized by Danfoss Redan A/S.

* Stated pressure loss values are complete, incl. pipes, heat exchanger and valves.

Danfoss Redan A/S District Heating Omega 7, Sften DK-8382 Hinnerup Denmark
Tel.: +45 87 43 89 43 Fax: +45 87 43 89 44 redan@danfoss.com www.redan.danfoss.dk

VL.GP.G2.02 Danfoss 03/2014

Scale

1:5

kg

Weight

DHW: Capacity examples, 10C / 45C


Plate heat
exchanger

Code no.:

Options:
Cover H 410 x W 310 x D 210 mm
Circulation set for mounting on site
Safety valve set

60

DHW
capacity
[kW]
32.3
32.3
32.3
32.3
41.0
41.0
53.0
53.0

Insulated*

* Akva Lux II is fully insulated and available with out w/o white cover.

190

60
40

40

Connections sizes:
DH, DHW, DCW:
Circulation:

XB 06H-1 26

190

Dimensions (mm):
Insulated:
Insulated with cover:

Connections:
1. Domestic cold water (DCW)
2. Domestic hot water (DHW)
3. District heating (DH) supply
4. District heating (DH) return
5. Circulation

463
403
145,5

Design specifications:
Nominal pressure (prim/sec.):
Max. supply temperature:
DCW static pressure:
Min. P:
Brazing material (HEX):

DH
supply A

145,5

DHW

463
403

DCW

DKDHR

MAKING MODERN LIVING POSSIBLE

Termix
One Solar Light
Domestic hot water module for flats, single-family houses
and apartment buildings with up to 10 apartments
Domestic hot water module with heat exchanger
and thermostatic control. Designed for wall-mounting.

Application
The Termix One Solar Light is an instantaneous water heater, featuring
superb heat extraction and high performance. The Termix One Solar Light
is applicable for heating systems
with buffer accumulators, solar systems or for other heat sources, where
avery low return temperature is preferred. The water heater is available
in three sizes, either for 1 apartment,
for 1-4 apartments or for 5 up to 10
apartments. The large heat exchanger cools out the water in the primary
return line very efficiently, thereby
creating a very good operation
economy. A flow switch in cold water
mains is controlling the primary heating pump. An optional circulation
pump together with a thermostat can
maintain the circulating temperature
at adesired temperature.
Domestic hot water (DHW)
The domestic hot water is prepared in
the heat exchanger and the temperature is regulated with a thermostatic
control valve. The patented sensor
accelerator accelerates the closing
of the thermostatic control valve and
protects the heat exchanger against
overheating and lime scale formation.

districtenergy.danfoss.com

The sensor accelerator and the thermostatic control valve also works as
a bypass keeping the heat exchanger
and supply line warm. This shortens
the waiting periods. The sensor accelerator helps to ensure a stable hot
water temperature by varying loads,
flow temperatures and differential
pressure without the need for readjusting the valve. There is no additional pressure loss on the secondary
side of the DHW heat exchanger with
a thermostatic control. Therefore this
type of regulation can be used by low
pressure in the cold water mains.

FEATURES AND BENEFITS

Domestic hot water module


DHW regulation with an
accelerated thermostatic control
Capacity: Up to 90 kW on DHW
DHW in sufficient quantity
Operates independent of differential
pressure and flow temperature
Minimum space required
for installation

Options

Pipes and plate heat exchanger


made of stainless steel

The water heater can be supplied


with the following:

Minimized risk of lime scale


and bacteria formation

- Built in non-return valve and safety


valve mounted in the cold water
supply
- Circulation set
- Grey-lacquered steel cover
- Two valve options (with or without
DVGW approved valves for domestic water)
Construction
All pipes are made of stainless steel.
The connections are made by nuts
and gaskets.

Termix One Solar Light


Circuit diagram example
230V

M
21
1

230V
21

13

1
21

35

48

45

11A

1
2

39

63

B
Termix One Solar Light
O Termix Sensor Accelerator
B Heat exchanger DHW
M Electrical wiring box
1 Ball valve

2 Single check valve


4 Safety valve
7 Thermostatic valve
11A Domestic hot water pump,
w/built in check valve

Technical parameters:
Nominal pressure:
DH supply temperature:
DCW static pressure:
Brazing material (HEX):

PN16
Tmax = 120C
Pmin = 0,5bar
Copper

Weight incl. cover:

20kg (incl. packing)

13 Charging pump
21 To be ordered separately
35 Ball valve / non-return valve
39 Connection closed
45 Flow switch

wall

Options:
Safety valve and
non-return valve (10bar)
Circulation
Cover
4 ball valves
4 ball valves; hereof 2 with DVGW
approval (ball valve length,
incl. 1 gasket: 60mm) (DVGW ball valve
length, incl. 1 gasket: 79mm)

H714 W300 D160


H714 W315 D165
H960 W400 D190

Connections:
1. Domestic cold water (DCW)
2. Domestic hot water (DHW)
3. Buffer tank (BT) supply
4. Buffer tank (BT) return
5. Circulation
Connections sizes:
All connections:
G (int. thread)

Cover:
Grey-lacquered

steel sheet
Dimensions (mm):
Without cover:
With cover:
With circulation
With cover:

48 Air vent, manual


63 Sieve

seen from above

DHW: Capacity examples 10C/50C


Substation
type
Type 1
w/AVTB 15
1 household
Type 3
w/AVTB 20
5 to 10*
huoseholds

DHW
capacity
[kW]
29,3
38,2
37,8
52,3
60,0
66,0
80,0
90,0

Supply flow Return flow Pressure loss Flow rate


primary
primary
primary
secondary
[C]
[C]
[kPa]
[l/h]
60
23,0
20
630
60
25,2
45
822
70
20,0
20
816
70
22,4
45
1128
60
23,0
35
1280
60
24,0
45
1426
70
20,3
35
1730
70
21,0
45
1940

Substation
type
Type 2
w/AVTB 20
up to 4
households

DHW
capacity
[kW]
34,7
47,1
45,1
65,6

Supply flow Return flow Pressure loss Flow rate


primary
primary
primary
secondary
[C]
[C]
[kPa]
[l/h]
60
24,4
20
744
60
26,8
45
1014
70
21,3
20
972
70
23,8
45
1410

* Capacity for 10 households at 70 C DH flow temperature

Gemina Termix A/S Member of the Danfoss Group Navervej 15-17 DK-7451 Sunds Denmark
Tel.: +45 9714 1444 Fax: +45 9714 1159 mail@termix.dk www.heating.danfoss.com

VL.JV.A1.02 Danfoss 10/2014

DENSMT/PL

Data sheet

ThermoClean
Domestic water heating system with legionella growth
prevention through thermal disinfection
Description/Application

The ThermoClean system is compact and


effective solution for legionella-free domestic
water heating. The system uses the thermal
disinfection methods, whereby the reaction
temperature inside the installation is kept at
a constant temperature of 70 C.
The ThermoClean system is dimensioned
in such a way that the water is warranted to
remain in the reaction area of the device for
at least 5 minutes. During tap operation, the
reaction temperature of 70 C is cooled down to
the required hot water temperature within the
system. This is not achieved by the addition of
cold water, but through an additional re-cooling
heat exchanger which cools the disinfected
water, while preheating cold water, that
simultaneous preheat the cold water.
The hot water temperature can be set at
any temperature between 50 C and 60 C.1
It means that the installation of a scaling
protection device on the taps is redundant if the
temperature is adjusted accordingly.
Due to the connection of the circulation into the
system a continual thermal disinfection of the
hot water is ensured.
The high quality stainless steel design of reaction
and buffer storage tank, heat exchanger and
piping is hygienically perfect, offers a maximum
in operational safety and can be universally used
in combination with the wide range of materials
used in the connected domestic water supply
network.
The recommended temperature is 60 C.

Main system data:


Primary
Type
Max. operating temp. (C)
Max. operating pressure (bar)
Working medium
2
On request

Secondary
DL/Combi

100 (150)2
16 (25)2
Circulation water

90
10
DHW

Approvals and Standards:


- DVGW3 Working paper W 553 Calculation for circulation systems in DHW installations,
- DVGW3 Working paper W 551 Technical method for prevention of legionella growth,
- DIN 1988 - Code of practice for drinking water installations (TRWI) (when related),
- DIN EN 806 - Specifications for installations inside buildings conveying water for human consumstions,
- DIN EN 1717 - Protection against pollution of potable water installations and general requirements
of devices to prevent pollution by backflow.
German Technical and Scientific Association for Gas and Water

DEN-SMT/PL

VD.KR.D5.02 Danfoss 09/2014

Data sheet

ThermoClean Domestic water heating system

ThermoClean-DL
Domestic water heating system with electronic
controls, a stainless steel reaction storage tank,
charging and re-cooling brazed plate heat
exchangers as well as charging pump, shut-off
valves and complete stainless steel piping.

Ordering

ThermoClean-Combi
Domestic water heating system with electronic
controls, a combined stainless steel reaction and
domestic hot water storage tank, charging and
re-cooling brazed plate heat exchangers as well
as charging pump, shut-off valves and complete
stainless steel piping.
The ThermoClean-Combi requires less
installation space provided adequate height in
the installation place is available.

Explanation, ThermoClean types


ThermoClean-DL 0200 TCTRL

Electronic controller type

Reaction tank volume (liter)
Type

DL with reaction storage tank and brazed plate heat
exchangers

Combi with combined reaction and DHW storage tank and

brazed plate heat exchangers

Domestic water heating system with charging

and re-cooling system unit
ThermoClean
Type
200
350
500
750
1000
1300

Code No.
-DL
004X1347
004X1348
004X1349
004X1350
004X1351
004X1352

-Combi
004X1343
004X1344
004X1345
004X1346
-

incl. electronic controller ThermoContol

VD.KR.D5.02 Danfoss 09/2014

DEN-SMT/PL

Data sheet

ThermoClean Domestic water heating system

Accessories 4

ThermoClean-DL
1. Domestic hot water storage tank
The ThermoClean system must be combined
with additional domestic hot water storage
tanks to provide the required capacity for peak
consumption. The required storage tank capacity
is based on the calculated peak flow and the
length of the consumption period.
The recommendations provided overleaf for the
total storage tank capacity are based on peak
consumptions lasting 1 hour or according to
customer demands. If the consumption periods
are shorter, the storage tank capacity can be
reduced accordingly.
We recommend the utilization of the following
storage tanks:
- Stainless steel domestic hot water storage tank
series SE,
- Tank sizes: 150 ... 8000 liters,
- Optimum adaptation to requirements due
to optional combination of multiple storage
tanks.
2. Over-tapping protection
Several unexpected factors can result in the
complete consumption of the available storage
tank capacity, which again can lead to the
addition of domestic cold water to the hot water
network that has not run through a proper
thermal disinfection. The potential causes are for
example:
- Heating medium not available in sufficient
quantity or at the adequate temperature,
- Insufficient heat transfer in the heat exchanger
due to fouling,
- Technical defect of a system component (e.g.,
failure of the charging pump),
- Peak consumption continues longer than the
calculated consumption period.

To address this issue, we offer products


complementing our ThermoClean system that
provide effective protection against system overtapping. If the storage tank capacity of thermally
disinfected domestic water is beginning to run
out, the protection interrupts the cold water
supply to the system until the charging process
has once again provided sufficient quantities of
thermally disinfected domestic hot water via the
reaction storage tank. Only after this process is
complete, the cold water supply is established
and the tapping of domestic hot water can
be continued. The device is controlled via the
ThermoClean system control with a manual
switch (ON/OFF/AUTOMATIC).
Over-tapping protection consisting of:
- Motorized butterfly valve, nominal diameter
corresponds to the selected ThermoClean
system, actuator 1~230 V, three-point signal,
- Control thermostat with stainless steel
immersion pocket.
ThermoClean-Combi
1. Over-tapping protection
Please refer to above section ThermoClean-DL.
4

accessories for separately order

Technical data

Type

Perfor
mance
index

Max. power
Connected
for peak
load
consumption

NL5
kW
kW
200
-6
84 .. 46
140
350
-6
147 .. 80
245
500
-6
210 .. 114
350
-DL
750
-6
315 .. 171
525
1000
-6
420 .. 228
700
1300
-6
546 .. 296
910
350
15 .. 9
55 .. 30
91
500 28 .. 13
71 .. 39
119
-Combi
750 41 .. 21
88 .. 48
147
1000 52 .. 29
101 .. 55
168
5
Performance index NL acc. to DIN 4708
6
Dependent on the additional storage tank(s)

DEN-SMT/PL

Heating
(Hot)
water flow
at VL = 75 C
l/h
2480
4440
6480
9650
12960
16980
1620
2120
2620
2970

VD.KR.D5.02 Danfoss 09/2014

Domestic hot water


capacities
Permanent
Peak
capacity
capacity
l/h
l/h
l/s
1330 .. 600 5000 1,389
2330 .. 1050 7500 2,083
3330 .. 1500 9000 2,500
5000 .. 2250 12000 3,333
6670 .. 3000 15000 4,167
8670 .. 3900 20000 5,556
870 .. 390
4000 1,111
1130 .. 510 4000 1,111
1400 .. 630 7000 1,944
1600 .. 720 7000 1,944

Charge
flow
total

Circ.
flow
(max.)

l/h
2400
4200
6000
9000
12000
15600
1560
2040
2520
2880

l/h
1070 .. 1800
1870 .. 3150
2670 .. 4500
4000 .. 6750
5330 .. 9000
6930 .. 11700
690 .. 1170
910 .. 1530
1120 .. 1890
1280 .. 2160

Resistance
Heating DHW
Circ.
water (max.) (max.)
kPa
kPa
kPa
24
54
19
20
64
20
22
58
20
23
59
23
29
65
27
35
86
30
20
56
18
21
56
19
22
49
14
24
49
14

Data sheet

ThermoClean Domestic water heating system

Design and function

CPU
ECD
1

HEL

45

47

4
CVE

DTA
RTA

SFV

CVD

5
HEC

LPU

46

RTA
HEL
HEC
LPU
CPU
SFV
CVE
ECD
CVD
DTA

reaction tank/vessel
HEX charging/load
HEX cooling
charging pump/load
circulation pump (on site/by customer)
safety valve
control valve electrical
electronic controller DHW
control valve electrical domestic
domestic buffer tank (accessory)
shut off device

1) domestic water cold


2) domestic water hot
3) circulation
4) heating supply
5) heating return
45) to domestic buffer tank
(stainless steel) top
46) from domestic buffer tank
(stainless steel) below
47) from domestic buffer tank
thermometer

balancing valve

drain/air vent (on site/by customer)

sensor (direct, cable/universal, surface)

check valve
sampling valve

The heat exchanger brings the system volume to


the disinfection temperature of 70 C.
A temperature sensor at the exit of the heat
exchanger monitors this temperature and
regulates the application of heat energy
accordingly. The system is dimensioned to
ensure that the domestic hot water remains in
the reaction area for at least 4 minutes to warrant
the extermination of the legionella bacteria.
The entire system volume is maintained at the
defined disinfection temperature. Only when
the water is tapped, the required quantity of
water is cooled down to the demanded network
temperature (50 ... 60 C) while the new cold
water that is being added is preheated.

VD.KR.D5.02 Danfoss 09/2014

Temperature fluctuations are balanced out by


the mixing valve, so that the precise degree of
water temperature indicated is definitely being
maintained. Proven control technology ensures
that the domestic hot water network is not
heated up during breaks in tapping.
If the consumption volume during peak times
exceeds the charge flow of the system, the
available storage tank volume is tapped. The
optionally available over-tapping protection
ensures that during unexpected functions (e.g.
peak tapping continues for a period exceeding
the determined consumption period) the cold
water supply is suspended until sufficient
thermally disinfected domestic water is once
again available through the charging process via
the reaction tank.
The circulation water from the network enters
the system, is once again heated up to 70C by
the charge heat exchanger and consequently
incorporated into the thermal disinfection
process continually.

DEN-SMT/PL

Data sheet

ThermoClean Domestic water heating system

Sizing

For dimensioning and selection of ThermoClean


system please contact with Danfoss local sales
representative.

Mounting

ThermoClean-DL
After setting up, connect reaction and DHW
storage tank, charge/re-cooling system unit
via the pre-installed connections. Next the
heating and domestic water connections, mains
connections. Commissioning as described in the
installation and operating instructions.

ThermoClean-Combi
After setting up, connect combination and DHW
storage tank, charge/re-cooling system via the
pre-installed connections. Next the heating
and domestic hot water connections, mains
connections. Commissioning as described in the
installation and operating instructions.

Dimensions

ThermoClean-DL ThermoClean-Combi
B1

B1

B2
45 46

1 4 3

47
2
3

H2

H1

H1

4
2

25

H2

25

B2

T2

47
3

D
d

T2
T1

D
d

46

T1

45


B1
approx.

B2
approx.

mm
1905
1915
2025
2365
2570

mm

740
930
980

mm
1730
1795
1845
1970
2220

1080

2245

2680

mm
1565
2065
2110
2270
2550

mm

mm

200
350
500
750
1000

500

640

600
7509
8009

1300

2575

9009

Type

-DL

H2
approx.

H1

1000

T1
T2
approx. approx.10

mm

mm

725

600

1100
1200

825
990
965

1250

995

VD.KR.D5.02 Danfoss 09/2014

Weight

1, 2

4, 5

45-47

G/Rp
G 1
G 1

G/Rp
G 1
G 1
G 1
G 23/8
Rp 2
Rp
21/2

DN
25/20
40

G/Rp
G 1
G 1

6509

G 23/8

920

Rp
2

350
1995
500
640
1500
500
2035
600
740
1600
7509
-Combi
1800
800
750
2115
750
890
1750
9
1000 2115
850
990
1900
750
7
For ThermoClean type -DL incl. charging unit
8
Mounted on the ThermoClean-Combis tank
9
min. door width; when needed components has to demounted
10
max. width of frame
11
raw weight (without insulation/package)
All connection axis measures are approximate and have a tolerance of +/- 15 mm.

DEN-SMT/PL

Connections

50/40
65/50

G 1

G 1

20
25/20

G 1

G 1

32/20

G 23/8
Rp 2

Storage
tank11

Re-cooling
unit7

Charging
unit8

kg
70
90
90
155
210

kg
140
160
170
230
250

kg
-

235

300

100

15
20

105

25

70
90
145
195

Data sheet

ThermoClean Domestic water heating system

VD.KR.D5.02 Danfoss 09/2014

DEN-SMT/PL

Data sheet

ThermoClean Domestic water heating system

DEN-SMT/PL

VD.KR.D5.02 Danfoss 09/2014

Data sheet

ThermoClean Domestic water heating system

VD.KR.D5.02 Danfoss 09/2014

DEN-SMT/PL

Data sheet

ThermoDual- CM (Charging module)

General Description / Use

Maximum operating
parameters

Materials

Domestic hot water provision by storage charging


principle is an efficient solution that fulfils all hygienic
requirements. Hot water is stored at temperatures that
kill or prevent the growth of pathogens. Favourable
habitats for the proliferation of bacteria such as legionella
do not exist, provided the system is operated in accordance
with the instructions. Ideally this requires an integrated
circulation management. When combined with optimally
hygienic stainless steel water tanks from our SE/SES series,
these systems are the ideal solution where security of
supply is of the essence, particularly at peak load.
The systems essential benefits are:
hygienically safe
efficient cooling of the primary medium
optimum use of energy
free choice from a wide range of energy sources
a t all times sufficient hot water temperature to meet
hygienic requirements
constant hot water temperature

Primary
Maximum permissible supply temperature, primary
Maximum permissible operating pressure, primary
Rated pressure, primary
Maximum permissible pressure differential, primary
Secondary
Maximum permissible temperature, secondary
Maximum permissible operating pressure, secondary

1.0 bar(g)

Rated pressure, secondary


Mains power supply / maximum power consumption

PN10
230V DC / 4.0 A

Pipes, fittings, flanges, valves (domestic side)

Capacity
[kW]
140
210
280
350
420
455

DEN-SMT/PL

90C
10 bar(g)

Minimum required pressure (static), water supply

ditto (heating side)


Heat exchanger
Insulation

Code numbers

90C / 150C (without/with safety function)


10/20 bar(g) Pumps and 3-way valve variant/
PN10 / PN25 2-way valve variant
only 2-way valve variant: 25 bar (up to 210kW) /16 bar

VD.IQ.I2.02

Pump +
3-way mixing valve
004X1400
004X1401
004X1402
004X1403
004X1404
004X1405

Danfoss 09/2014

1.4571, bronze or brass as per DIN EN 1982,


also considering DIN 50930-06 and UBA guidelines
P235GH-TC1, CuSn5Pb5Zn5-C (RG-5), ST37.0, EN-JL1040 (GG25)
1.4404 with Cu solder
PU hard foam =0.029 W/mK (50%ENEV)

Code no.
Pump control
2-way valve
(PWM control signal) (without safety function)
004X1406
004X1412
004X1407
004X1413
004X1408
004X1414
004X1409
004X1415
004X1410
004X1416
004X1411
004X1417

2-way valve
(with safety function)
004X1418
004X1419
004X1420
004X1421
004X1422
004X1423
1

Data sheet

ThermoDualCM (Load module)

Circuit
diagram

3-Ways (MIX)

Pump

2-Ways

Control options on heating side

Shut-off valve
Non-return valve
Check valve
Balancing valve
Air vent
Drain
Dain
sampling valve
(optional)

Technical data

FRp
(70->25C)
[m3/h]

Pump
dpr
[kPa]

140

2.4

210
280
350
420
455

3.8
5.1
6.3
7.8
8.0

Type
ThermoDual

Capacity
[kW]

CM 140
CM 210
CM 280
CM 350
CM 420
CM 455

HEL
LPU
HPU
CPU
SFV
CVE
ECD

Heat exchanger, charging


Charging pump
Heating pump
Circulation pump
Safety valve
Motorized control valve (2/3-way)
Electronic domestic hot water controller
(ThermoControl-3)
STW Safety thermostat (optional)
DTA Domestic hot water storage tank (installed by customer)
1

Domestic water (cold/charging)

Domestic hot water (hot/charging network)

Circulation (inlet)

Heating supply

Heating return

TC

Sensors (general: direct , immersion, surface)


FLA with designation as for controller

2-way
dp
[kPa]

3-way
dpr
[kPa]

FRTW
(10->60C)
[m3/h]

52

21

38

2.4

61
44
34
17
23

30
29
30
30
22

47
34
19
17
17

3.6
4.8
6.0
7.2
7.8

FRC*
(55->60C)
[m3/h]

C
dpr**
[kPa]

41

1.0/2.4

80/43

57
45
30
17
16

1.5/2.4
2.0/2.4
2.5/3.4
3.0/3.4
3.3/3.4

70/43
57/43
51/30
38/30
34/31

DW
dpr
[kPa]

FR: Flow rate p: primary dpr: Remaining pump head dp: Pressure loss DW: Domestic water C: Circulation
* flow rate: standard setup / maximal possible
** remaining pump head for: standard setup / maximal possible

VD.IQ.I2.02

Danfoss 09/2014

Data sheet

ThermoDualCM (Load module)

Function
ECD

TC
DTA
CPU

HEL
TC

TC

CVE

Low load operation (with circulation)


In low-load operation, all the cold water passes
over the instantaneous water heater (HEL). If the
tap load is less then the flow pre-set at the balancing
valve, a portion of the water (tap volume) flows
trough the top of the tank (DTA) as bypass to the
taps. The remaining volume is drawn from the
bottom of the tank so that the tank (DTA) continues
to be charged. The total tap load is covered by the
heat exchanger (HEL), while the storage tank (DTA)
is not being discharged.

5
TC
TC
LPU

ECD

TC
DTA
CPU

HEL
TC

TC

CVE

Peak load operation


In peak-load operation, the pre-set flow of cold
water passes through the instantaneous water
heater (HEL) and the remainder flows through the
tank (DTA) from bottom to top. The tap load is
covered from the instantaneous water heater (HEL)
and the storage tank (DTA) is simultaneously
discharged. Once tap operation ceases, the storage
tank (DTA) is charged as described below.

5
TC
TC
LPU

ECD

Charging operation (no tap load / circulation)


If there is no consumption the storage tank (DTA)
is being charged. The total charging flow is drawn
from the bottom of the tank (DTA) and passed via
the instantaneous water heater (HEL) to the top of
the tank (DTA).

TC
DTA
CPU

HEL
TC

TC

CVE

4
5

TC
TC
LPU

VD.IQ.I2.02

Danfoss 09/2014

Data sheet

ThermoDualCM (Load module)

Dimensions

Connections:
Type
ThermoDual

DW C/H

Circ.

1/2 G ISO

3 G ISO

1 "A
1 "A
1 "A
1 "A
1 "A
1 "A

1 "A
1 "A
1 "A
1 A
1 "A
1 A

CM 140
CM 210
CM 280
CM 350
CM 420
CM 455

Weight [kg]

HTG (DN)
SL, RL
4/5 PN10
Rp
1 "
1 "
1
1 "
2
2"

HTG (DN)
SL, RL
4/5 PN25
WELD
42.4
42.4
48.3
48.3
60.3
60.3

Pump +
3-way v.

Pump
control
(PWM)

2-way v.

86
93
99
104
113
119

83
89
95
99
104
110

92
96
104
108
118
124

156

174

174

110-160

VD.IQ.I2.02

Danfoss 09/2014

411

634

1830

910

Correlation of connections
1

Domestic cold water

Domestic hot water

Circulation (inlet)

Heating supply line

Heating return line

Produced by Danfoss A/S 09/2014

Data Sheet

ThermoDual-FLS (welded type)

General Description/Use

Maximum operating
parameters

Materials

Domestic hot water provision by instantaneous heater is


an efficient and hygienic optimal solution. Hot water is
not stored and will be produced only on request. Thus,
low temperatures in drinking water can be reduced to a
necessary minimum.
Habitats for bacteria,such as legionella are virtually nonexistent. If the conditions for connection of these systems
are given (sufficiently high capacity on heating side to
cover peak load) or buffer tanks is present, these systems
can be used unrestricted.
Significant advantages of the system are:
no storage of drinking water
efficient cooling of the primary media
optimum use of energy
independent choice of different energy sources
at any time sufficiently high domestic hot water
temperature, that fulfils all hygienic requirements
low space requirement
lime scale is largely avoided

Primary
Maximum permissible supply temperature, primary
Maximum permissible operating pressure, primary
Rated pressure, primary
Maximum permissible pressure differential, primary
Secondary
Maximum permissible temperature, secondary
Maximum permissible operating pressure, secondary

1.0 bar(g)

Rated pressure, secondary


Mains power supply / maximum power consumption

PN10
230V DC / 4.0 A

Pipes, fittings, flanges, valves (domestic side)

Capacity
[kW]
140
210
280
350
420
455

DEN-SMT/PL

90C
10 bar(g)

Minimum required pressure (static), water supply

ditto (heating side)


Heat exchanger
Insulation

Code numbers

90C / 150C (without/with safety function)


10/20 bar(g) Pumps and 3-way valve variant/
PN10 / PN25 2-way valve variant
only 2-way valve variant: 25 bar (up to 210kW) /16 bar

Pump +
3-way mixing valve
004X1424
004X1425
004X1426
004X1427
004X1428
004X1429

VD.HE.J3.02 Danfoss 09/2014

1.4571, bronze or brass as per DIN EN 1982,


also considering DIN 50930-06 and UBA guidelines
P235GH-TC1, CuSn5Pb5Zn5-C (RG-5), ST37.0, EN-JL1040 (GG25)
1.4404 with Cu solder
PU hard foam =0.029 W/mK (50%ENEV)

Code no.
Pump control
2-way valve
(PWM control signal) (without safety function)
004X1430
004X1436
004X1431
004X1437
004X1432
004X1438
004X1433
004X1439
004X1434
004X1440
004X1435
004X1441

2-way valve
(with safety function)
004X1442
004X1443
004X1444
004X1445
004X1446
004X1447
1

Data Sheet

ThermoDual-FLS (welded type)

Circuit diagram

Shut-off valve
Non-return valve
Check valve
Balancing valve
Air vent
Drain
Drain, sampling valve
(optional)

Flow sensor

Technical data

FRp
(70->25C)
[m3/h]

Pump
dpr
[kPa]

140

2,4

210
280
350
420
455

3,8
5,1
6,3
7,8
8,0

Type
ThermoDual

Capacity
[kW]

FLS 140
FLS 210
FLS 280
FLS 350
FLS 420
FLS 455

HEL
HPU
CPU
SFV
CVE
ECD
STW
BTA

Heat exchanger
Heating pump
Circulation pump
Safety valve
Motorized control valve (2/3-way)
Electronic domestic hot water controller (ThermoControl-3)
Safety thermostat (optional)
Hot water buffer tank (installed by customer)

Domestic water (cold)

Domestic hot water (hot network)

Circulation (inlet)

Heating supply

Heating return

TC

Sensors (general: direct , immersion, surface)


FHZ: with designation as for controller

2-way
dp
[kPa]

3-way
dpr
[kPa]

FRDW
(10->60C)
[m3/h]

52

21

38

2,4

61
44
34
17
23

30
29
30
30
22

47
34
19
17
17

3,6
4,8
6,0
7,2
7,8

FRC*
(55->60C)
[m3/h]

C
dpr**
[kPa]

12

1,0/2,4

80/43

26
28
33
41
39

1,5/2,4
2,0/2,4
2,5/3,4
3,0/3,4
3,3/3,4

70/43
57/45
51/30
38/30
34/31

DW
dp
[kPa]

FR: Flow rate p: primary dpr: Remaining pump head dp: Pressure loss DW: Domestic water C: Circulation
* flow rate: standard setup / maximal possible
** remaining pump head for: standard setup / maximal possible
2

VD.HE.J3.02 Danfoss 09/2014

Data Sheet

ThermoDual-FLS (welded type)

Function

Flow systems provide heated domestic water when requested. By a heat exchanger (HEL), the cold
water flowing into connection (1will be heated up to set point and provided to the consumer at the
connection (2). The electronic controller (ECD) is measuring the relevant temperatures and controls the
target values that are held constant in all operating conditions. This is i.e. achieved by influencing the
speed of the heating pump (HPU), so that the outlet temperature always matches the specified value.
In case of using a control valve, the flow is directly controlled by an electrical actuator. Short-term peaks
in consumption are registered at the flow sensor to intervene quickly and avoid large temperature
fluctuations. The cooled- circulation water from the network (connection 3) is constantly heated in
heat exchanger (HEL), even in times of draw-off , reheated and the temperature control (sensor) in the
amount of the controlled circulation pump ( CPU) influenced so that only the necessary amount flows
to maintain constant power set point.
The capacity for the peak load is to ensure either by buffering heating water in a tank (BTA) or there
must be a sufficiently large connection value available. The Recharging of a buffer (e.g. from a boiler)
can a requisition (sensor / switch contact) on controller (ECD) using an on-site charging pump (LPU).
The operation of the system by a controlled heating pump (HPU) is only possible without differential
pressure between the connections (4) and (5).

Dimensions

Connections:
Type
ThermoDual
FLS 140
FLS 210
FLS 280
FLS 350
FLS 420
FLS 455

DW C/H

Circ.

1/2 G ISO

3 G ISO

1 A
1 A
1 A
1 A
1 A
1 A

1 A
1 A
1 A
1 A
1 A
1 A

Weight [kg]

HTG (DN)
SL, RL
4/5 PN10
Rp
1
1
1
1
2
2

HTG (DN)
SL, RL
4/5 PN25
WELD
42,4
42,4
48,3
48,3
60,3
60,3

Pump +
3-way v.

Pump
control
(PWM)

2-way v.

82
85
91
96
105
111

79
82
87
91
95
101

88
89
96
100
109
115

429

1830

550

223

910

174

VD.HE.J3.02 Danfoss 09/2014

174

411

156

634

Correlation of connections
1

Domestic cold water

Domestic hot water

Circulation (inlet)

Heating supply line

Heating return line

Data Sheet

ThermoDual-FLS (welded type)

Accessories

Heating buffer storage tank, standing model,


Type: PSS
Charging-/Discharging Connections
as threaded or flange connection

Materials

Steel EN 1.0025 S235JRG2


Raw inside, outside undercoat - black
PU soft foam with PVC RAL 5015 up to
PSS 300: 80 mm / from PSS 500: 100 mm

tank (shell)
Insulation (from 750 Liter as bypack/not mounted)

Maximum operating
parameters

Type
I

H
mm

H1
mm

H2
mm

Maximum permissible operating temperature

TZ

110C

Maximum permissible operating pressure

PZ

6bar

H3
mm

H4
mm

H5
mm

H6
mm

H7
mm

HMa
mm

d
mm

Dx
mm

D
mm

Tilted
height mm

4/5
G

4/5
DN/PN

Weight
kg

300

1470

1270

1070

780

620

320

215

115

1130

550

660

710

1550

1 1/4"

85

500

1880

1665

1430

990

650

350

245

145

1550

600

710

800

2010

2"

115

750

1890

1635

1400

1000

670

370

265

165

1500

750

860

950

1945

2"

175

1000

1930

1655

1370

1020

690

390

285

185

1500

850

960

1050

2090

2"

240

1500

2050

1740

1505

1070

725

445

320

220

1550

1000

1110

1200

2160

50/16

325

2000

2330

1995

1750

1220

770

510

375

265

1770

1100

1210

1300

2450

65/16

375

d
24

22

4
Dx

22

H max

45

H1

H2

22

25
22
5

H5
H6
H7

H4

H3
4

45

VD.HE.J3.02 Danfoss 09/2014

5
26

4
5
6
22
24
25
26

Charging-/Discharging conn. supply (hot)


Charging-/Discharging conn. return (cold)
Solar conn. / Reserve El. Heater Rp 2
Thermostat / Thermometer Rp 1/2
Air Vent Rp 3/4
Inspection, diameter opening 205 mm
Drain Rp 3/4

Produced by Danfoss A/S 04/2014

ThermoClean
Domestic water heating system for hospitals, sports centers, hotels
as well as dwelling-houses
Domestic water heating system with legionella growth prevention
through thermal disinfection
Application
ThermoClean is a compact and
eective
system
solution
for
legionella-free
domestic
water
heating. ThermoClean is suitable for
hospitals, sports centers, hotels and
dwelling houses, where effectively
prevent the development and
growth of legionella is needed. The
system is available in two different
types with separate reaction (-DL) or
combination (-Combi) storage tank
which contains the charging and recooling unit. These units are equipped
with brazed (-DL/-Combi) plate heat
exchangers.
Domestic hot water (DHW)
The ThermoClean system uses
the thermal disinfection method,
whereby the reaction temperature
inside the installation is kept at a
constant temperature of 70 C. It is
dimensioned in such a way that the
water is warranted to remain in the
reaction area of the device for at least
5 minutes. The system is equipped
with electronic controls for controlling

VL.KR.F3.02 Danfoss 12/2012

of the charging temperature and the


temperature in buffer storage tank.

setup the unit should be connected


with reaction (combination) storage
tank.

Domestic hot water circulation


The ThermoClean system is supplied
with connection for DHW circulation
including balancing valve and a nonreturn valve as a standard as well as
circulation pump as an option.
Options
The ThermoClean-DL systems can
be combined with additional buffer
storage tanks to provide the required
capacity for peak consumption. The
system can be also equipped with the
over-tapping protection to prevent
system cool-down during over
tapping.
Construction
The combination and reaction
storage tank, plate heat exchangers
and piping are made of stainless steel.
All pipe connections are made by
welding. The charging and re-cooling
unit is mounted on a separated
common frame construction. After

FEATURES AND BENEFITS


Domestic water heating system
Electronic control of DHW temperature
Max. capacity: 46-546/30-101 kW1
Reaction storage tank capacity:
200-1300/350-1000 l1
Reliable prevention of legionella
bacteria
Continuous thermal disinfection of
DHW circulation
Low operating cost
Compact design and easy installation
ThermoCleanDL/-Combi

ThermoClean
Circuit diagram - example
RTA reaction tank/vessel
HEL HEX charging/load
HEC HEX cooling
LPU charging pump/load
CPU circulation pump (on site/by customer)
SFV safety valve
CVE control valve electrical
ECD electronic controller DHW
CVD control valve electrical domestic
DTA domestic buffer tank (accessory)

CPU
ECD
1

HEL

45

47

1) domestic water cold


2) domestic water hot
3) circulation
4) heating supply
5) heating return
45) to domestic buffer tank
(stainless steel) top
46) from domestic buffer tank
(stainless steel) below
47) from domestic buffer tank
(stainless steel) top

4
CVE

DTA
RTA

CVD

SFV
HEC

LPU

46

thermometer
shut off device

drain/air vent (on site/by customer)

balancing valve

check valve

sensor (direct, cable/


universal, surface)

Technical parameters:
Type -DL/-Combi
Nominal pressure: PN 16 (25)2
DH supply temp.: Tmax = 100 (150)2 C

sampling valve

Options:
Additional buffer storage tank
Butterfly valve with electrical actuator
Control thermostat with stainless steel
immersion pocket

Available on request

DHW: Capacity examples


Type

-DL
-Combi

200
500
1000
350
500
1000

Performance
index
NL3
-4
-4
-4
15 .. 9
28 .. 13
52 .. 29

Connected
load
kW
84 .. 46
210 .. 114
420 .. 228
55 .. 30
71 .. 39
101 .. 55

Max. power
for peak
consumption
kW
140
350
700
91
119
168

Circ.
flow
(max)
l/h
1070 .. 1800
2670 .. 4500
5330 .. 9000
690 .. 1170
910 .. 1530
1280 .. 2160

Resistance
Heating
water
kPa
24
22
29
20
21
24

DHW
(max)
kPa
54
58
65
56
56
49

Dimensions
Circ.
(max)
kPa
19
20
27
18
19
14

H
mm

W
mm

D
mm

1730
2110
2550
1995
2035
2115

1905
2025
2570
1500
1600
1900

640
740
980
640
740
990

Connections
Weight
kg

1, 2

210
260
460
185
210
325

11/2
23/8
21/2
11/2
11/2
13/4

11/4
13/4
2
11/4
11/4
11/2

4, 5

45-47

25/20 11/2
50/40 23/8
50/40 21/2
20
25/20
32/20
-

Performance index NL acc. to DIN 4708


Dependent on the additional storage tank(s)

3
4

VL.KR.F3.02 Danfoss 12/2012