C120N Circuit-Breaker
Multi 9 Merlin Gerin

The C120N circuit-breaker is a miniature device adapted to final distribution


in the industry and tertiary sectors:
c Outgoer in medium power switchboard.
c Enclosure supply end.

Operation

C120N: 18351

c Protection of cables against overloads and short-circuits:


v C curve: standard networks,
v B curve: for very long cables or networks supplied by low short-circuit
current generators,
v D curve: for circuits with a strong inrush current
(motors, transformers).
c Manual control and isolation.

Advantages
c Compliance with international standards: EN 60898 and IEC 60947-2.
c Ratings from 63 to 125 A (1 to 4-pole).
c Breaking capacity of 10 000 A under 400 V.
c Characteristics adapted to the industrial environment:
v insulation voltage Ui: 500 V,
v impulse voltage Uimp: 6 kV.
c Service breaking capacity: Ics = 75 % Icu.
c Positive break indication.
c Installation on rail using bistable pawl.
c Total compatibility with Pragma enclosures and Prisma cubicles.
c Design, performances and range coherent with C60 circuit-breakers.
c Remote tripping and indication by adding clip-on electrical auxiliaries,
which are common with C60 circuit-breakers.
c Earth leakage protection when combined with a Vigi C120 module.

The range
TmC120
C120N CircuitRemote control breaker
(M9 FP 37/A .en
product data sheet)

A1

MERLIN GERIN

multi 9
C120N

MERLIN GERIN

multi 9

Tm

C63

C120 1-2 P

A1

240/415Va
10000
3

OF
auto

SD

230V ~
MN

auto

A2

18311

(M9 FP 204/A .en and


M9 FP 205/A .en
product data sheets)

18356

MX

Vigi C120 module

O - OFF

1P

A2

or/and

Auxiliaries

N/1 3

N/2

MERLIN GERIN

multi 9
C120N
C63
415Va
10000
3

(M9 FP 58/C .en


product data sheet)

1 3

2 4

18360

O - OFF

O - OFF

2P

2P

3P

4P

Vigi C120
In 0,030A a

18563

test

11

12

91

11

94

14
9

12

mm

N/1 3

92
N/2

14

+ + + + +
SD

OF

SD - OF

r
e
s
e
t

T
e
s
t

mm

14

21
95

22
98

24
96

MERLIN GERIN

MERLIN GERIN

multi 9
MN

multi 9
MX OF

D1 D2
U<

220.415Va
26960

110.130V
220.415Va
26946

MERLIN GERIN

multi 9
C120N
C63

1 3 5

415Va
10000
3
2 4 6

18364

O - OFF

O - OFF

O - OFF

mm

mm

12

26924

11

92

94

26927

91

Vigi C120

In 0,030A a

18566

test

3P
OF+OF OF
or OF+SD

SD

MN or
MN s

MX+OF
N/1 3

Accessories

MERLIN GERIN

multi 9
C120N
C63

1 3 5 7

415Va
10000
3
2 4 6 8

18371

O - OFF

O - OFF

O - OFF

O - OFF

(M9 FP 206/A .en product data sheet) 4P

Comb
Dividable busbars
plate

Screw
shield

Aluminium
cable terminal

We do more with electricity.

SHEET
OF
SHEET1 2TO
2 3

N/2

test

Inter-pole
barrier

Terminal
shield
Sub-distribution
terminal

Vigi C120

In 0,030A a

18563

Rotary
handle

Choice table
type

1P

Implementation

width in
mod. of
9 mm
3

rating
(A)

63
80
100
125

cat. no.
curve
B
18340
18341
18342
18343

C
18356
18357
18358
18359

D
18378
18379
18380
18381

63
80
100

18344
18345
18346

18360
18361
18362

18382
18383
18384

125

18347

18363

18385

c Designed for installation in modular enclosures and cubicles.


c Easy assembly and disassembly:
on symmetrical rail with bistable lock (immediate fixing).
c Simplified combination of circuit-breaker with auxiliaries: using clip-ons.
c Combination of circuit-breaker with Vigi C120 module using rigid cables:
quick with no risk of error (rating, order of phases, etc.).

2P
1

Technical data
Common electrical data
c Power circuit:
v ratings from 63 to 125 A set at 30C,
v max. voltage rating: 440 V AC,
v breaking capacity as in EN 60898:
type

1, 2, 3, 4P
3P
1

9
3

63

18348

18364

18386

80
100
125

18349
18350
18351

18365
18367
18369

18387
18388
18389

4P

12

63
80
100
125

18352
18353
18354
18355

18371
18372
18374
18376

18390
18391
18392
18393

breaking capacity
(A)
10 000

v breaking capacity as in IEC 60947-2 (Icu):


type
1P
2, 3, 4P

voltage
(V AC)
230415
voltage
(V AC)
130
230240
230240
400415
440

breaking capacity
(kA)
20
10
20
10
6

v fast closing,
v positive break indication:
opening is indicated by a green strip on the devices control toggle.
This indicator shows that all poles are open with a safety distance allowing
downstream interventions.
c Electrical durability:
v 10 000 cycles at In = 63 A,
v 5 000 cycles at In = 80125 A.
Tripping curves
the magnetic trip units operate:
c B curve: between 3 and 5 In.
c C curve: between 5 and 10 In.
c D curve: between 10 and 14 In.

Environment

Mechanical data
c Connection by:
v tunnel terminals with insulated guard (tightened using a screwdriver) for
copper cable:
- flexible from 1.5 to 35 mm2
- rigid from 1.5 to 50 mm2,
v aluminium cable terminals: from 16 to 50 mm 2,
v incomer terminal for rear connection with or without a lug,
v Insulated sub-distribution terminals, 3 copper cables:
- flexible from 1.5 to 10 mm2
- rigid from 1.5 to 16 mm2,
v screw connection: 5 screw up to 32 A,
v comb busbars for devices up to 63 A.
c Distribution using a Distribloc splitter.
c Durability: 20 000 cycles (O-C).
c Dimensions (w x h x d mm): 27 x N (number of poles) x 81 x 70.
c Weight (g): 1P: 205, 2P: 410, 3P: 615, 4P: 820.
M9 FP 202/A .en

c Degree of pollution 3.
c Tropicalisation: treatment 2
(relative humidity 95 % at 55C).
c Degree of protection:
v of case: IP 40D,
v of terminals: IP 20B.
c Operating temperature:
-30C to +60C.
c Storage temperature:
-40C to +70C.

Schneider Electric

DIT E D1 98 072 en
ART.

Merlin Gerin
F-38050 Grenoble cedex 9
tel. +33 (0)4 76 57 60 60
telex : merge 320 842 F

As standards, specifications and designs develop from time to


time, always ask for confirmation of the information given in
this publication.
Published by: Communication BTT-S2E
Design and layout by: HeadLines (38)

SHEET
OF3 3
SHEET 23TO

This document has been


printed on ecological paper

09/99

c120 side view (702x405x16M jpeg)

SHEET 3 TO 4

c120 3P front view (702x405x16M jpeg)

SHEET 4 TO END

You might also like