You are on page 1of 1

SBL T1 Exam Card - Philips Intera 3T

INFO PAGE
Total scan duration

4:11.2

Rel. signal level (%)

100

Act. TR/TE (ms)

9.0 / 3.5

ACQ matrix M x P

256 x 231

ACQ voxel MPS (mm)


REC voxel MPS (mm)

1.00 / 1.00 / 1.00


1.00 / 1.00 / 1.00

Scan percentage (%)

100

TFE shots

101

TFE dur.shot / acq (ms)

2462.7 / 1458.0
144.523407
2.269 / 191.5
0.388 / 1121.1

Min. T1 delay
Act. WFS (pix) /BW (Hz)
Min. WFS (pix) / Max. BW
(Hz)
SAR / head

< 7 %
Whole body / level
0.0 W/kg / normal
B1 rms [uT]
0.61 uT
PNS / level
80 % / normal
Sound Pressure level (dB) 18.006155
MOTION
Cardiac syncronization

no

Respiratory compensat

no

Navigator respiratory
compensation

no

Flow compensation

no

fMRI echo stabilization

no

NSA

DYN/ANG
Angio / Contrast enh.

no

Quantitative flow

no

CENTRA

no

Manual start

no

Dynamic study

no

Arterial Spin labeling

no

GEOMETRY
Nucleus
Coil selection 1
element selection
Coil selection 2
element selection
Dual coil
CLEAR
body tuned
FOV
RL(mm)
AP(mm)
FH(mm)
Voxel size FH(mm)
RL(mm)
AP(mm)
Recon voxel size(mm)
Fold-over suppression
Slice oversampling
Reconstruction matrix
Scan percentage (%)
SENSE
Overcontiguous slices
Stacks
slices
slice thickness (mm)
slice orientation
fold-over direction
fat shift direction
Chunks
PlanAlign
REST slabs
Interactive positioning

[N/A]
SENSE-Head-32P
selection 1
SENSE-Head-32AH
selection 1
yes
yes
no
256
232
170
1
1
1
1
no
default
256
100
yes
no
1
170
1
transverse
AL
L
1
no
0
no

OFFC/ANG
Stacks

Stack Offc. AP (P=+mm)

-19.2856312

RL (L=+mm)

4.03035402

FH (H=+mm)
Ang. AP (deg)

32.6415443
1.05257308

RL (deg)

-0.56958276

FH (deg)

-1.34385669

CONTRAST
Scan type
Scan mode
technique
Contrast enhancement
Acquisition mode
Fast Imaging mode
3D non-selective
shot mode
TFE factor
startup echoes
shot interval
(ms)
profile order
turbo direction
Echoes
partial echo
shifted echo
TE
Flip angle (deg)
TR
Halfscan
Water-fat-shift
Shim
Fat suppression
Water suppression
TFE prepulse
slice selection
delay
(ms)
PSIR
MTC
T2prep
Research prepulse
Diffusion mode
SAR mode
B1 mode
PNS mode
Gradient mode
SofTone mode

Imaging
3D
FFE
T1
cartesian
TFE
no
multishot
162
default
shortest
2462.70532
low_high
radial
no
no
shortest
8
user defined
no
maximum
auto
no
no
invert
no
user defined
1000
no
no
no
no
no
high
default
moderate
maximum
no

POSTPROC
Preparation phases
B0 field map
MIP/MPR
Images
Autoview Image
Calculated images
Reference tissue
Preset window contrast
Reconstruction mode
Save raw data
Hardcopy protocol
Ringing filtering
Geometry correction
Elliptical k-space
shutter

auto
no
no
M (3) no
M
(4) no
Grey matter
soft
real time
no
no
rectangular
default
default