You are on page 1of 26

Users Manual V2.

2008.01.21
BF-880X/870X Users Manual www.chiyu-t.com.tw

Table of Contents
1 About BF-880X/870X..................................................................................................................3
2 Features ........................................................................................................................................3
2.1 Characteristics..............................................................................................................3
2.2 Support functions .........................................................................................................3
2.2.1 User management.................................................................................................3
2.2.2 System management ............................................................................................4
2.2.3 Door mode............................................................................................................4
2.2.4 Log .......................................................................................................................4
2.2.5 Authentication......................................................................................................4
2.2.6 Real time event.....................................................................................................4
2.2.7 Auxiliary function ................................................................................................4
3 Operation window........................................................................................................................5
4 Users Menu.................................................................................................................................6
4.1 For password verify user (1:1 verify) ..........................................................................6
4.2 For card verify user (1:N verify)..................................................................................7
5 Administrator Menu.....................................................................................................................8
5.1 User ..............................................................................................................................9
5.1.1 Add User : register a new user .............................................................................9
5.1.1.1 Password verify user .....................................................................................9
5.1.1.2 Card verify user...........................................................................................10
5.1.2 Delete User : Del one registered user................................................................. 11
5.1.3 Activate User : To enable authority of user for using BF-660C ........................12
5.1.4 Deactivate Use : To disenable authority of user for using BF-880X/870X .......13
5.2 Settings.......................................................................................................................14
5.2.1 Date & Time: Set timedate and week of BF-880X/870X ..............................14
5.2.2 Password: Change managers password ............................................................14
5.2.3 IP Config: Set IP data of BF-880X/870X ..........................................................15
5.3 Settings.......................................................................................................................15
5.3.1 Reset UsersDelete all registered users ...........................................................15
5.3.2 Reset LogsDelete all logs...............................................................................16
5.3.3 IP ConfigReset IP to factory default ..............................................................16
5.3.4 Reset Group........................................................................................................17
5.4 Misc............................................................................................................................17
5.4.1 User&LogDisplay total number of registered users and total number of logs
17
5.4.2 Init CardInitial TM card to EM format ..........................................................18

1
BF-880X/870X Users Manual www.chiyu-t.com.tw

5.4.3 Write CardWrite ID number to TM card........................................................18


5.4.4 BF20/485 Reader ...............................................................................................19
6 Specifications .............................................................................................................................20
6.1 Module Features.........................................................................................................20
6.2 Power Supply .............................................................................................................20
6.2.1 Voltage ...............................................................................................................20
6.2.2 Current ...............................................................................................................20
6.3 Environment...............................................................................................................20
6.3.1 Temperature and humidity .................................................................................20
6.3.2 Immunity to electro static discharge ..................................................................20
6.4 Communication..........................................................................................................20
6.5 Drivers........................................................................................................................20
6.6 Capacity .....................................................................................................................20
6.7 Log entry memory......................................................................................................20
6.8 Size(yet to be set).......................................................................................................20
6.9 Weight ........................................................................................................................20
6.10 Authentication time....................................................................................................20
6.11 Register time ..............................................................................................................20
6.12 Input ...........................................................................................................................21
6.13 Display .......................................................................................................................21
7 Appendix....................................................................................................................................21
7.1 Note............................................................................................................................21
7.2 External connector .....................................................................................................21
7.3 Connection example...................................................................................................22

2
BF-880X/870X Users Manual www.chiyu-t.com.tw

1 About BF-880X/870X
BF-880X/870X is developed to manage entrance security, work place time and attendance,
over-work time verification and other situation requiring the presence of the authorized personnel.
BF-880X/870X supports various I/O protocols. Within 1 Card Reader, 128 X 64 pixel LCD screen,
10 push buttons, 6 function keys, and 1 buzzer. These equipments make BF-880X/870X
user-friendly.
Through the Chinese web inside and the function of Master/Slave, you can manage the branch
office easily. Beside that, the user can check the in/out log by using IE.

2 Features
2.1 Characteristics
z Entrance security, time and attendance, over-time management and other applications
BF-880X/870X system allows for entrance security, work place time and attendance, over-time work. Also,
situations that require the presence of the authorized persons at a secured point can take advantage of our
BF-880X/870X system.

z Special function keys may be configured to time and attendance and entrance access management
4 programmable function keys can be used to manage time and attendance. One BF-880X/870X can be
adapted to manage many different kinds of work involving site security control and time and attendance.

z Use of stand-alone modules and working in conjunction with an ACU


BF-880X/870X entrance control system may be used as stand-alone units to control entrance traffic or in
multiple module configurations Utilizing Weigand protocol to contain with an ACU. Also, direct connection
to a PC is possible via TCP/IP protocol when software library bundled. Because BF-880X/870X content RTC
and log management capabilities (up to 65,000 records), entrance security and other event management are
possible without an ACU.

z Support Weigan RS-485 and TCP/IP communication


Support 2 Weigan In (26), 1 Weigan Out (26), 1 RS-485 for card reader, 1 TCP/IP connector

2.2 Support functions

2.2.1 User management


Register a user, provides 2 type of register (1.Password 2.Card)
Provide 128designations and 128 departments
User can set the employee limit period separately by truly situation
User can set the attendance and time by the group
View all registered ID list
Delete a user or all users

3
BF-880X/870X Users Manual www.chiyu-t.com.tw

2.2.2 System management


You can use the Chinese Http server inside to revise the data and manage employee on IE
The system sets 2 level accounts and passwords to prevent the setting form change purposely
You can set the terminal number, title, description, maintenance time, card ID display format and
the master/slave function
You can check the slave data on the slave list
Set the communicate status on line. For example, IP ADDRESS, Gateway, DNS, Port Number,
Host Name.
Set the clock on line. You can revise it by your hand or connect to the time server to revise
everyday
Provide 40 in/out trigger setup
Provide 16 alarm clock setup
Upgrade firmware on line
You can backup or restore the user log directly
You can import all logs directly on line

2.2.3 Door mode


Provide 255 time set, 255 time zone, 200 group, 100 holiday
You can connect 16 reader to control 8 doors mostly
You can connect door lock controller or elevator controller to set the type of reader, relay trigger,
lock release time zone and anti-pass back level for every entrance
Monitor every entrance status on line
You can turn on or close door security by real situation

2.2.4 Log
Access log: each user or employee can check in or out log by through any computer
Query log by user number, terminal number, department, function key or time period
Query user first in and last out log in one day
Export the in/out log (TXT and XLS format)
Download the log by using the software program

2.2.5 Authentication
Authentication at the terminal by Card/Password
Collocate with group, time zone, card+password

2.2.6 Real time event


Display user I.D. Name on LCD at authentication time.

2.2.7 Auxiliary function


Exit button
Relay out for lock driver

4
BF-880X/870X Users Manual www.chiyu-t.com.tw

3 Operation window

Operation window
CHIYU Tech. THU Jan 01
THU 01 Jan
0152 0152
ID ID

Press F1 Enter ID Enter ID Place Card


twice + + Directly

Enter password THU Jan 01 User password: Chang


XXXXXXXXXX Eric
0152 ID 11647520
IDUnReged User 0152
Manager login Input unregistered ID 11 Verification Verify success
password

Function key description


Enter Administrator Mode
F1 Function key for Time & Attendance User Denied

F2 Function key for Time & Attendance Illegal card

Delete (Backspace)
F3 Function key for Time & Attendance
User password:
XXXXXX
F4 Function key for Time & Attendance

Confirm Asking password


verify
Cancel

0 9 Number key

5
BF-880X/870X Users Manual www.chiyu-t.com.tw

4 Users Menu

4.1 For password verify user (1:1 verify)


THU Jan 01
0152
ID

11 Verify 11 Verify
Place card directly Enter ID +

Illegal Card THU Jan 01 THU Jan 01


Unregistered ID
0152 0152
User Denied IDxxxxxxxxxx IDUnReged User

Legal Card Registered ID

User password:
XXXXXXXXXX

Correct Error

Chang User password:


Eric XXXXXXXXXX
ID 11647520 Password Error
0152 User Denied

Operation description Function key description


11 verifymax. 5000 users
Enter Administrator Mode
Method 1 F1 Function key for Time & Attendance
0 9 Enter ID
F2 Function key for Time & Attendance
Press Delete (Backspace)
F3 Function key for Time & Attendance
Enter password
0 9 610 digit F4 Function key for Time & Attendance
Press Confirm
Method 2
Cancel
Place sensor card on the coil directly
0 9 Enter password 0 9 Number key
610 digit

Press

Note1. If you use function key please press function


key first
2. If you want to show name on LCD then you
must enter name in BF-880X/870X web
tti

6
BF-880X/870X Users Manual www.chiyu-t.com.tw

4.2 For card verify user (1:N verify)

THU Jan 01
0152
ID

1N verify
Place sensor card
on the coil directly

Legal card Illegal card

Chang
Eric
ID 11647520
0152 User Denied

Operation description Function key description


1N verifymax. 5000 users
Enter Administrator Mode
Place sensor card on the coil directly F1 Function key for Time & Attendance
Note1. If you use function key please press function F2 Function key for Time & Attendance
key first
2. If you want to show name on LCD then you Delete (Backspace)
must enter name in BF-880X/870X web F3 Function key for Time & Attendance
setting
F4 Function key for Time & Attendance

Confirm

Cancel

0 9 Number key

7
BF-880X/870X Users Manual www.chiyu-t.com.tw

5 Administrator Menu
Administrator menu allows new user registration and deletion, and system configuration. Press F1 twice to
enter

CHIYU Tech. THU Jan 01


THU Jan 01
0152
0152
ID ID
Press F1 twice

Enter password
XXXXXX

Correct Error

1. User Enter password:


2. Settings XXXXXX
3. Reset Password Error
4. Misc.

Operation description Function key description


F1 Press F1 twice F1 Enter Administrator Mode/Page Up

0 9 Enter 6 digit password F2 Page Down


default value is 111111

Press F3 Delete (Backspace)

0 9 Press 14 to select F4 No use

Press to exit Confirm

Cancel

0 9 Number key

8
BF-880X/870X Users Manual www.chiyu-t.com.tw

5.1 User

5.1.1 Add User : register a new user

5.1.1.1 Password verify user

1. Add User
2. Delete User
3.Activate User
4.Deactivate use

Reg Already Present card


Modify User? Or Input id
YES(#)/NO(*) Registered xxxxxxxxxx

Unregistered

Reg Password ?
YES(#)/NO(*)

User password:
xxxxxxxxxx

Enter password +

User password: Reg Password ?


xxxxxxxxxx YES(#)/NO(*)

Reg Success Modify Success

Operation description Function key description

0 9 Press 1 F1 Enter Administrator Mode/Page Up

0 9 Enter ID or Place
sensor card on the coil
F2 Page Down

Press F3 Delete (Backspace)

Press to register password F4 No use

Enter password
0 9 Confirm
610 digit

Press Cancel

0 9 Number key

9
BF-880X/870X Users Manual www.chiyu-t.com.tw

5.1.1.2 Card verify user

1. Add User
2. Delete User
3.Activate User
4.Deactivate use

Reg Already Place card


Modify User? Or Input id
YES(#)/NO(*) Registered xxxxxxxxxx

Unregistered

Reg Password ?
YES(#)/NO(*)


Only Reg User ?
YES(#)/NO(*)

Only Reg User ?


YES(#)/NO(*)

Reg Success

Operation description Function key description

0 9 Press 1 F1 Enter Administrator Mode/Page Up


Place sensor card on the coil F2 Page Down
Press to cancel password register
F3 Delete (Backspace)
Press to confirm
F4 No use

NoteAfter register success please modify open Confirm


mode to card first , see 5.1.3
Cancel

0 9 Number key

10
BF-880X/870X Users Manual www.chiyu-t.com.tw

5.1.2 Delete User : Del one registered user

1. Add User
2. Delete User
3.Activate User
4.Deactivate use

2
Present card
Or Input id
xxxxxxxxxx

Unregistered Registered

Place card Place card


Or Input id Or Input id
xxxxxxxxxx
UnReged User Del Success

Operation description Function key description

0 9 Press 2 F1 Enter Administrator Mode/Page Up

0 9 Enter ID or Place F2 Page Down


sensor card on the coil
Press F3 Delete (Backspace)

F4 No use

Confirm

Cancel

0 9 Number key

11
BF-880X/870X Users Manual www.chiyu-t.com.tw

5.1.3 Activate User : To enable authority of user for using BF-660C

1. Add User
2. Delete User
3.Activate User
4.Deactivate use

3
Present card
Or Input id
xxxxxxxxxx

Unregistered Registered

Place card Place card


Or Input id Or Input id

UnReged User

status Active

Function key description


Operation description
F1 Enter Administrator Mode/Page Up
0 9 Press 3

Enter ID or Place F2 Page Down


0 9
sensor card on the coil
F3 Delete (Backspace)
Press
F4 No use

Confirm

Cancel

0 9 Number key

12
BF-880X/870X Users Manual www.chiyu-t.com.tw

5.1.4 Deactivate Use : To disenable authority of user for using BF-880X/870X

1. Add User
2. Delete User
3.Activate User
4.Deactivate use

4
Present card
Or Input id
xxxxxxxxxx

Unregistered Registered

Place card Place card


Or Input id Or Input id

UnReged User

status Deactiv

Operation description Function key description

0 9 Press 4 F1 Enter Administrator Mode/Page Up

0 9 Enter ID or Place F2 Page Down


sensor card on the coil
Press F3 Delete (Backspace)

F4 No use

Confirm

Cancel

0 9 Number key

13
BF-880X/870X Users Manual www.chiyu-t.com.tw

5.2 Settings

5.2.1 Date & Time: Set timedate and week of BF-880X/870X

1. Date & Time


Operation description Function key description
2. Password
3. IP Config
0 9 Press 1 F1 Enter Administrator Mode/Page Up

0 9 Enter time HHMMSS F2 Page Down


1

Input Time
F3 Delete (Backspace)
HHMMSS 0 9 Enter date YYMMDD
F4 No use
Press
Enter Confirm
Time + 0 9 Enter week 17

Input Date Press Cancel


YYMMDD
0 9 Number key

Enter
Date +

Input Day
X

5.2.2 Password: Change managers password

1. Date & Time


2. Password Operation description Function key description
3. IP Config
0 9 Press 3 F1 Enter Administrator Mode/Page Up

3 0 9 Enter 6 digit password F2 Page Down



Input New P/W
XXXXXX Press F3 Delete(Backspace)

Enter 6 digit password F4 No use


0 9
Press Confirm

Input P/W Again

XXXXXX Cancel

0 9 Number key
Match Mismatch
Input P/W Again Input P/W Again
XXXXXX XXXXXX
P/W Set Success Input P/W Error

14
BF-880X/870X Users Manual www.chiyu-t.com.tw

5.2.3 IP Config: Set IP data of BF-880X/870X

1. Date & Time Operation description Function key description


2. Password
3. IP Config 0 / Press 4 F1 Enter Administrator Mode/Page Up

Enter IPSubnet mask Page Down


0 9 F2
4 Gateway

IP: 192168000012 Press F3 Delete(Backspace)


SM: 255255255000
GW: 192168000001 F4 No use
IP: Note
The format of IPsubnet mask and gateway are as follow
Confirm
If you want to set IP as 192.168.0.12 then enter
192168000012
THU Jan 01
If you want to set subnet mask as 255.255.255.0 then Cancel
0152 enter 255255255000
ID If you want to set gateway as 192.168.0.1 then enter 0 9 Number key
192168000001

5.3 Settings

5.3.1 Reset UsersDelete all registered users

1. Reset Users Operation description Function key description


2. Reset Logs
3.IP Config 0 9 Press 1 F1 Enter Administrator Mode/Page Up
4.Reset Group
1 Press F2 Page Down
Del All user
Are You Sure ? F3 Delete (Backspace)
YES(#)/NO(*)
F4 No use

Confirm
Del All user
Are You Sure ?
YES(#)/NO(*)
Cancel
Deleting
0 9 Number key

Del All user


Are You Sure ?
YES(#)/NO(*)
Del Success

15
BF-880X/870X Users Manual www.chiyu-t.com.tw

5.3.2 Reset LogsDelete all logs

1. Reset Users Operation description Function key description


2. Reset Logs
3.IP Config 0 9 Press 2 F1 Enter Administrator Mode/Page Up
4.Reset Group
2 Press F2 Page Down
Del All LOG
Are You Sure ? F3 Delete (Backspace)
YES(#)/NO(*)
F4 No use

Confirm
Del All LOG
Are You Sure ?
YES(#)/NO(*) Cancel
Deleting
0 9 Number key

Del All LOG


Are You Sure ?
YES(#)/NO(*)
Del Success

5.3.3 IP ConfigReset IP to factory default

1. Reset Users Operation description


2. Reset Logs Function key description
3.IP Config 0 9 Press 3
4.Reset Group F1 Enter Administrator Mode/Page Up
3 Press
F2 Page Down
Reset IP Config
Are You Sure ?
YES(#)/NO(*)
F3 Delete (Backspace)

F4 No use

Confirm
Please Wait
Cancel

0 9 Number key

THU Jan 01
0152
ID

16
BF-880X/870X Users Manual www.chiyu-t.com.tw

5.3.4 Reset Group

1. Reset Users
2. Reset Logs Function key description
3.IP Config
4.Reset Group F1 Enter Administrator Mode/Page Up
3 Operation description
F2 Page Down
0 9 Press 4
Del GP/TZ/HD
Are You Sure ?
F3 Delete (Backspace)
YES(#)/NO(*) Press

F4 No use

Del GP/TZ/HD
Confirm
Are You Sure ?
YES(#)/NO(*)
Del Succeess
Cancel

0 9 Number key

THU Jan 01
0152
ID

5.4 Misc.

5.4.1 User&LogDisplay total number of registered users and total number of logs

1. User&Log Operation description Function key description


2. Init Card
3.Write Card 0 9 Press 1
F1 Enter Administrator Mode/Page Up
4.BF20/485Read
1
F2 Page Down
User00000
Log00000 F3 Delete (Backspace)

F4 No use

Confirm

Cancel

0 9 Number key

17
BF-880X/870X Users Manual www.chiyu-t.com.tw

5.4.2 Init CardInitial TM card to EM format

1. User&Log
2. Init Card Operation description Function key description
3.Write Card
4.BF20/485Read 0 9 Press 2 F1 Enter Administrator Mode/Page Up
2
Press F2 Page Down
Present Card Place sensor card on the coil
Push # Init Card F3 Delete (Backspace)

F4 No use

Confirm
Init Success
Init Other card?
YES(#)/NO(*) Cancel

0 9 Number key

5.4.3 Write CardWrite ID number to TM card

1. User&Log Operation description Function key description


2. Init Card
3.Write Card 0 9 Press 3 F1 Enter Administrator Mode/Page Up
4.BF20/485Read
3 0 9 Enter ID+
F2 Page Down
Input Card ID Place sensor card on the coil
F3 Delete (Backspace)

F4 No use
Enter ID
+ Confirm
Input Card ID
XXXXXXXX
Place TM Card
Cancel

0 9 Number key

Write Success
Write Other card?
YES(#)/NO(*)

18
BF-880X/870X Users Manual www.chiyu-t.com.tw

5.4.4 BF20/485 Reader

1. User&Log Function key description


2. Init Card
3.Write Card F1 Enter Administrator Mode/Page Up
4.BF20/485Read Operation description
4 0 9 Press 2 F2 Page Down
Entry:-xxxxxxxx Press
Exit: -xxxxxxxxx F3 Delete (Backspace)
BF20:xxxxxxxxx
Place sensor card on the coil F4 No use

Confirm

Cancel

0 9 Number key

19
BF-880X/870X Users Manual www.chiyu-t.com.tw

6 Specifications
6.1 Module Features
Main board
Keyboard module
LCD module
Build-In Card Reader

6.2 Power Supply


6.2.1 Voltage
+9V to +30V DC

6.2.2 Current
Average: 300Ma, 12V
Maximum power consumption: 500mA

6.3 Environment
6.3.1 Temperature and humidity
Operating temperature: 0 to 55
Storage temperature: -20 to 85
Operating humidity: 0% to 95%
Storage humidity: 0% to 95%

6.3.2 Immunity to electro static discharge


0~4kV contact discharge: No unrecoverable error
0~8kV air discharge: No user detectable error

6.4 Communication
1 RJ-45 port(10/100M) for management
1 rs-232 port
1 RS-485 port
Meet RS232, RS485 specifications

6.5 Drivers
2 Relay Out (COM, NO, NC)

6.6 Capacity
5000 persons with 1 card/1 password per person.

6.7 Log entry memory


65000 log entries total.

6.8 Size(yet to be set)


BF-880X: 170 mm(H) X 143 mm(W) X 48 mm(D)
BF-870X: 156 mm(H) X 140 mm(W) X 50 mm(D)

6.9 Weight
BF-880X: 480g.
BF-870X: 385g.

6.10 Authentication time


Average : shorter than 1 second.

6.11 Register time


Average: shorter than 2 second

20
BF-880X/870X Users Manual www.chiyu-t.com.tw

6.12 Input
10 number keys + 6 function keys

6.13 Display
1 Buzzer
1 LCD: 128 X 64 pixels
2 LED

7 Appendix
7.1 Note
The first thing when you install BF-880X/870X
Please change the system password first. BF-880X/870Xs password is fixed at 111111 initially.
It makes a security problem.

Please do these when BF-880X/870X has out of function.


Power off and power on again, so initialize BF-880X/870X. After initializing BF-880X/870X, if
it has same status still, please calls on Chiyus service center.

7.2 External connector

21
BF-880X/870X Users Manual www.chiyu-t.com.tw

7.3 Connection example

z Time & Attendance System Application

22
BF-880X/870X Users Manual www.chiyu-t.com.tw

z Multi-doors Control System Application

23
BF-880X/870X Users Manual www.chiyu-t.com.tw

z 485 Connection example

BF-660X/BF/880X BF-670X/BF-870X

z Electronic Lock Control


Lock open when lock is power off

24
BF-880X/870X Users Manual www.chiyu-t.com.tw

Lock open when lock is power on

z Fire Alarm

25

You might also like