You are on page 1of 410

Topic Section.

Page

Introduction ........................................................................................................ 0.1


1. Table of Contents .................................................................................................. 1.0
Plant and Office Locations ................................................................................. 1.1
(Blank Page) ...................................................................................................... 1.2
Index .......................................................................................................... 1.3-1.14
2. Tongue & Groove Pipe.......................................................................................... 2.0
Reinforced Concrete Pipe Brochure / Information ............................................ n/a*
Tongue & Groove Pipe Basic Dimensions ......................................................... 2.1
Reinforced Concrete Arch Pipe, 15' - 96" .......................................................... 2.2
Tongue & Groove Pipe - Typical Bend ............................................................... 2.3
Tongue & Groove Pipe - Typical Concentric Tee ............................................... 2.4

In Index, click on page title (invisible link)


to view catalog page.

You may scroll forward, page-to-page by pushing on your keyboard.


You may scroll back, page-to-page by pushing on your keyboard.

On each page, click on this


On each page, click on this (invisible) link to exit catalog.
(invisible) link to view Hanson
Contact Information.

On each page, click on this


(invisible) link to go to Index.
Note:
* - Page not numbered but in sequence as shown.
TITLE PLANT STATE .
SECTION PAGE DATE

Grand Prairie
Guide to Links Houston TX n/a 01-25-10
Waco HEIDELBERGCEMENT Group

Go To Index
Product Catalog
Texas

HEIDELBERGCEMENT Group
Introduction

Concrete pipe, in various forms, has been used for over 5,000 years. Ancient pipe and drain systems
have been discovered in India, Iraq, Crete and other locations that date back to the third millennium B.C.
The Romans used crude types of concrete and masonry to construct pipes and aqueducts throughout
their empire, some of which are still in use today.
Concrete pipe, as we know it today, had its origins in Europe and North America in the mid 1800's.
Farmers began using concrete drain tiles in the 1830's. Concrete pipe was used for sanitary sewers as
early as 1842 in the U.S. and the railroads began using concrete pipe for roadbed culverts in the 1850's.
The rich history of concrete pipe has spawned an industry which today produces an economical high
quality product for numerous applications.
Hanson Pipe & Precast is the leader in today's pipe industry. Founded in Texas in 1933, the company
has expanded throughout North America. As an industry leader, we have developed staffs of experts
in engineering, manufacturing, quality management, marketing, sales and service.
Our industry is dynamic, as are our products. We have adapted to meet the changing needs of the
construction industry, yet are dedicated to the traditional requirements of quality, service and economy.
As required throughout history, a buried pipe must fulfill two functions. First, it is a conduit which must
efficiently convey the fluid it was designed to carry. Second, and equally important, it is a structure which
must be able to support the weight of the earth and live loads above it. Unlike flexible pipe materials such
as steel, aluminum and plastic, concrete pipe is able to fulfill both functions because of its inherent
strength and rigidity.
The volume of concrete pipe specified and installed in the U.S. has increased every year, which
demonstrates the confidence engineers and contractors have in its features, which include:
Strength - concrete pipe can be designed to withstand any combination of loads with
minimal embedment support.
Durability - concrete pipe can function in various environments for generations.
"Spec it, bury it and forget it"
Hydraulic efficiency - concrete pipe has a demonstrated and documented Manning "n"
value of 0.010."
Local availability - concrete pipe is produced locally to meet local needs.
Adaptability - concrete pipe can be designed, built and installed to meet any
project requirements.
Economy - concrete pipe has repeatedly proven to provide the low-cost reliable system.
This catalog has been prepared to assist you in planning, designing and specifying with concrete pipe
and precast products. We have attempted to present the details in a useful and logical manner. The
details included by no means represent all we can produce; they merely illustrate our different product
lines. We take pride in saying, "Our only limitation is your imagination."
Thank you for your interest in concrete pipe, and congratulations for understanding that often, innova-
tion is knowing what not to change.
Not all products shown in the sections that follow are inventoried at each of our plants. We encourage
you to call our sales office nearest to you for availability, or with questions or suggestions.

TITLE PLANT STATE .


SECTION PAGE DATE

Grand Prairie
Introduction to Concrete Products Catalog Houston TX 0.1 01-25-10
Waco HEIDELBERGCEMENT Group
www.hansonpipeandprecast.com

Texas Catalog
Products:
Reinforced Concrete Pipe CrownSpan Bridge Sections
Precast Box Culverts Retaining Walls
Jacking and Microtunneling Pipe Noise Barrier
PVC Lined Concrete Pipe Other Products on Request
Inlet Structures

North Texas Engineering: Regional Office: South Texas Engineering:


1003 N. MacArthur Blvd. 300 E. John Carpenter Fwy. 11201 FM 529
Grand Prairie, TX 75050 Irving, TX 75062 Houston, TX 77041
Phone: (972) 262-3600 Phone: (972) 653-5500 Phone: (713) 466-6306
FAX: (972) 264-6236 FAX: (713) 466-3503

Texas Sales Offices:


Austin Hewitt Longview
Phone: (512) 385-3950 (Located near Waco, Texas) Phone: (903) 759-9422
FAX: (512) 385-1725 P.O. Box 688 FAX: (903) 759-0458
Hewitt, TX 76634
Dallas (Grand Prairie) Phone: (254) 666-4000 Robstown
Gravity Pipe and Precast FAX: (254) 666-4441 (FAX) Phone: (361) 767-1060
Phone: (972) 262-3600 FAX: (361) 767-1100
FAX: (972) 264-6236

Fort Worth Houston (Jersey Village) San Antonio


Phone: (817) 332-1375 Phone: (713) 466-6306 Phone: (210) 661-2351
FAX: (817) 870-9015 FAX: (713) 466-6897 FAX: (210) 661-5393

Plant Locations:
Austin, TX Grand Prairie, TX (Precast) Longview, TX
Cedar Hill, TX Hewitt, TX (Precast) Robstown, TX
Fort Worth, TX Houston, TX (Gravity Pipe) San Antonio, TX
Grand Prairie, TX (Gravity Pipe) Houston, TX (Precast)

TITLE PLANT STATE .


SECTION PAGE DATE

Plant and Office Locations All Plants TX 1.1 01-25-10


HEIDELBERGCEMENT Group
Topic Section.Page

Introduction ........................................................................................................ 0.1


1. Table of Contents .................................................................................................. 1.0
Plant and Office Locations ................................................................................. 1.1
(Blank Page) ...................................................................................................... 1.2
Index .......................................................................................................... 1.3-1.14
2. Tongue & Groove Pipe.......................................................................................... 2.0
Reinforced Concrete Pipe Brochure / Information ............................................ n/a*
Tongue & Groove Pipe Basic Dimensions ......................................................... 2.1
Reinforced Concrete Arch Pipe, 15' - 96" .......................................................... 2.2
Tongue & Groove Pipe - Typical Bend ............................................................... 2.3
Tongue & Groove Pipe - Typical Concentric Tee ............................................... 2.4
Tongue & Groove Pipe - Typical Eccentric Tee.................................................. 2.5
Tongue & Groove Pipe - Typical Concentric Wye .............................................. 2.6
Tongue & Groove Pipe - Typical Eccentric Wye ................................................ 2.7
Tongue & Groove Pipe Reducers - Option 1 ..................................................... 2.8
Tongue & Groove Pipe Reducers - Option 2 ..................................................... 2.9
Tongue & Groove Radius Pipe ........................................................................ 2.10
Tongue & Groove Pipe - Joint Material Estimate .............................................. 2.11
3. Rubber Gasket Pipe .............................................................................................. 3.0
Confined Groove Joint, 12 - 66 - Basic Dimensions ........................................ 3.1
Confined Groove Joint, 42 - 120 - Basic Dimensions ..................................... 3.2
Single Offset Joint, 12 - 66 - Basic Dimensions .............................................. 3.3
Single Offset Joint, 36 - 120 - Basic Dimensions ............................................ 3.4
Confined Groove or Single Offset Joint - Bend ........................................................ 3.5
Confined Groove or Single Offset Joint - Concentric Tee ........................................ 3.6
Confined Groove or Single Offset Joint - Eccentric Tee........................................... 3.7
Confined Groove or Single Offset Joint - Concentric Wye ....................................... 3.8
Confined Groove or Single Offset Joint - Eccentric Wye ......................................... 3.9
Confined Groove or Single Offset Joint - Reducers-Option 1 ....................................... 3.10
Confined Groove or Single Offset Joint - Reducers-Option 2 ........................................ 3.11
Gasketed Radius Pipe ..................................................................................... 3.12
Joining Proceedure for "O" Ring Gaskets ....................................................... 3.13
Joining Proceedure for Self Lubricating Gaskets ............................................ 3.14
Joining Proceedure for Profile Gaskets ........................................................... 3.15

Note:
* - Page not numbered but in sequence as shown.
TITLE PLANT STATE .
SECTION PAGE DATE

Grand Prairie
Index Houston TX 1 .3 01-25-10
Waco HEIDELBERGCEMENT Group
Topic Section.Page
4. Precast Box Culverts .............................................................................................. 4.0
Precast Box Culverts Brochure / Information .................................................... n/a*
Precast Box Culverts Standard Dimensions ........................................................ 4.1
Precast Box Culvert Bends .................................................................................. 4.2
Precast Box Transition - Option 1 ........................................................................ 4.3
Precast Box Transition - Option 2 ........................................................................ 4.4
Precast Box Joint Material Estimate .................................................................... 4.5
Box Culvert Installation Instructions .................................................................... 4.6
5. Precast Manholes ................................................................................................... 5.0
Precast Manholes Brochure / Information ......................................................... n/a*
Precast Manhole Assembly Diagram ................................................................... 5.1
Precast Manhole Joints ....................................................................................... 5.2
Tee-Type Manhole Assembly, 48 - 66 Line Size ............................................... 5.3
Tee-Type Manhole Assembly, 72 Line Size & Larger ......................................... 5.4
4' I.D. Manhole - Regular Base w/Reducing Cone .............................................. 5.5
5'/4' & 6'/4 I.D. Manhole - Extended Base w/Reducing Cone .............................. 5.6
Details: 4', 5' & 6' I.D. Precast Regular Manhole Base ........................................ 5.7
5' x 4' Conical Adaptor ......................................................................................... 5.8
48" Manhole Reducing Cone Detail..................................................................... 5.9
60" thru 96" Large Base Manhole - 35 & 45 Ft. Depth ...................................... 5.10
Type "C" Manhole .............................................................................................. 5.11
ASTM C-478 Special Base ................................................................................ 5.12
Typical Wetwells - Various Diameters................................................................ 5.13
10' I.D. Wetwell w/ Extended Bottom Slab ........................................................ 5.14
12' I.D. Wetwell w/ Extended Bottom Slab ........................................................ 5.15
O-Ring & Profile Gasket - Installation on Manholes .......................................... 5.16
Pipe to Manhole Connector Installation Guide .................................................. 5.17
6. Bridge Structures .................................................................................................... 6.0
Precast Bridge Unit Brochure / Information ....................................................... n/a*
Precast Bridge Unit Information - 2 ..................................................................... 6.1
Crown Span Design Data Sheet .......................................................................... 6.2
Crown Span Design Data Sheet (w/ Skew Angle) ............................................... 6.3
Typical Modular Precast Bridge Unit ................................................................... 6.4
Precast Modular Bridge Span w/Parapet Rail ..................................................... 6.5
Precast Modular Bridge Span w/Post and Rail .................................................... 6.6
Precast Modular Bridge Span, Typical Sections .................................................. 6.7
Blank Page .......................................................................................................... 6.8
Bridge Products - Full Flow Constants .................................................... 6.11 - 6.19
Blank Page ........................................................................................................ 6.20

Note:
* - Page not numbered but in sequence as shown.
TITLE PLANT STATE .
SECTION PAGE DATE

Grand Prairie
Index Houston TX 1.4 01-25-10
Waco HEIDELBERGCEMENT Group
Topic Section.Page
7. SET's and Headwalls ........................................................................................ 7.0
Precast Headwall (Type B) for Reinforced Concrete Pipe ............................. 7.1
Reinforced Concrete Pipe Sloped End Sections ........................................... 7.2
Control Dimensions - RCP - Sloped End Sections ........................................ 7.3
Precast Safety End Treatment for Reinforced Concrete Pipe ....................... 7.4
Precast Culvert End Sections for Reinforced Concrete Pipe ........................ 7.5
8. Grated Inlets ..................................................................................................... 8.0
#12 Catch Basin ............................................................................................ 8.1
#14 Catch Basin ............................................................................................ 8.2
#18 Catch Basin (Surface Grate Inlet) City of Austin ..................................... 8.3
#20 Catch Basin ............................................................................................ 8.4
#24 Catch Basin ............................................................................................ 8.5
#26 Catch Basin ............................................................................................ 8.6
30" x 30" Inlet ................................................................................................ 8.7
30" x 30" Catch Basin with Type "A" Grated Inlet .......................................... 8.8
3' x 3' Standard Catch Basin ......................................................................... 8.9
9. Junction Boxes ................................................................................................. 9.0
Top Options for 3' x 3' Precast Box ................................................................ 9.1
Top Options for 4' x 4' Precast Box ................................................................ 9.2
5' x 5' Precast Box ......................................................................................... 9.3
6' x 6' Standard Junction Box with Variable Depths ...................................... 9.4
7' x 7' Standard Junction Box with Variable Depths ...................................... 9.5
8' x 8' Standard Junction Box with Variable Depths ...................................... 9.6
10' x 10' Standard Junction Box with Variable Depths .................................. 9.7
12' x 12' Standard Junction Box with Variable Depths .................................. 9.8
2' x 3' Junction Box with Variable Depths ...................................................... 9.9
2' - 6" x 5' Junction Box with Variable Depths .............................................. 9.10
3' x 4' Standard Junction Box (2-Piece) with Variable Depths ..................... 9.11
4' x 5' Standard Junction Box (2-piece) with Variable Depths ..................... 9.12
4' x 6' Standard Junction Box with Variable Depths .................................... 9.13
4' x 8' Standard Junction Box with Variable Depths .................................... 9.14
5' x 7' Standard Junction Box with Variable Depths .................................... 9.15
6' x 8' Standard Junction Box with Variable Depths .................................... 9.16
6' x 12' Standard Junction Box with Variable Depths .................................. 9.17
8' x 10' Standard Junction Box with Variable Depths .................................. 9.18
8' x 14' x 8' Standard Junction Box with Variable Depths ............................ 9.19
6' x 6' x 6' Junction Box ............................................................................... 9.20

TITLE PLANT STATE .


SECTION PAGE DATE

Grand Prairie
Index Houston TX 1.5 01-25-10
Waco HEIDELBERGCEMENT Group
Topic Section.Page
10. Inlets ................................................................................................................... 10.0
North Texas Inlets (D/FW) ............................................................................. 10.a
5' Curb Inlet w/ 5.0 Invert w/6" Wall - Dallas/ Fort Worth .............................. 10.a.1
5' Curb Inlet w/ 5.0 Invert w/8" Wall - Dallas/ Fort Worth .............................. 10.a.2
6' Curb Inlet - Dallas/ Fort Worth .................................................................. 10.a.3
6' Curb Inlet w/5.0' Invert - Dallas/ Fort Worth .............................................. 10.a.4
10' Curb Inlet - Dallas/ Fort Worth ............................................................... 10.a.5
10' Curb Inlet w/5.0' Invert - Dallas/ Fort Worth ............................................ 10.a.6
15' Curb Inlet - Dallas/ Fort Worth ................................................................ 10.a.7
15' Curb Inlet w/5.0' Invert - Dallas/ Fort Worth ............................................ 10.a.8
20' Curb Inlet - Dallas/ Fort Worth ................................................................ 10.a.9
2-Grate Combination Inlet - 6' .................................................................... 10.a.10
3-Grate Inlet - 10' ........................................................................................ 10.a.11
4-Grate Inlet - 6' .......................................................................................... 10.a.12
6-Grate Inlet - 10' ........................................................................................ 10.a.13
12" Trench Drain ......................................................................................... 10.a.14
24" Trench Drain ......................................................................................... 10.a.15
Central Texas Inlets (Waco & Austin) ......................................................... 10.b
5' Curb Inlet - City of Austin .......................................................................... 10.b.1
10' Curb Inlet - City of Austin ........................................................................ 10.b.2
15' Curb Inlet w/ 4' - 0" Invert - City of Austin ............................................... 10.b.3
South Texas Inlets (San Antonio) ................................................................. 10.c
5' Curb Inlet - City of San Antonio ................................................................ 10.c.1
5' Curb Inlet w/5.0' Invert - City of San Antonio ............................................ 10.c.2
10' Curb Inlet - City of San Antonio .............................................................. 10.c.3
15' Curb Inlet - City of San Antonio .............................................................. 10.c.4
Houston Area Inlets ...................................................................................... 10.d
Storm Sewer Type "A" Grate Inlet - City of Houston..................................... 10.d.1
Storm Sewer Type "B" Inlet w/ Grate Top - City of Houston ......................... 10.d.2
Storm Sewer Type "BB" Inlet w/ Grate Top - City of Houston ....................... 10.d.3
Type "C" Curb Inlet - 3' x 3' - City of Houston' .............................................. 10.d.4
Type "C" Curb Inlet - 30" x 60" ..................................................................... 10.d.5
Type "C" Curb Inlet - 36" x 60" ..................................................................... 10.d.6
Type "C" Curb Inlet - 36" x 60" with Left or Right Extension ......................... 10.d.7
Type "C" Curb Inlet - 36" x 60" with Left and Right Extensions .................... 10.d.8
Type "C" Wing Extension .............................................................................. 10.d.9
Type "B" Curb Inlet - City of Houston ......................................................... 10.d.10
Type "BB" Curb Inlet with Frame and Grate ............................................... 10.d.11
(Houston Inlets continued on next page.)
TITLE PLANT STATE .
SECTION PAGE DATE

Grand Prairie
Index Houston TX 1 .6 01-25-10
Waco HEIDELBERGCEMENT Group
Topic Section.Page
10. Inlets (continued) ................................................................................................ 10.0
Houston Area Inlets (continued) ................................................................... 10.d
Type "C" Curb Inlet - 5' x 5'' ........................................................................ 10.d.12
Type "C2" Curb Inlet - City of Houston ....................................................... 10.d.13
Type "C1" and Type "C2A" Curb Inlet - City of Houston ............................. 10.d.14
Storm Sewer Type "C-1", "C-2" & "C-2A" - City of Houston ....................... 10.d.15
Storm Sewer Type "D" Inlet - City of Houston ............................................ 10.d.16
Storm Sewer Type "D-1" Inlet - City of Houston ......................................... 10.d.17
Type "E" Curb Inlet - City of Houston ......................................................... 10.d.18
Storm Sewer Type "E" Inlet - City of Houston............................................. 10.d.19
Storm Sewer Type "H-2" Inlet - City of Houston ......................................... 10.d.20
11. Interceptors ...................................................................................................... 11.0
Acid Dilution Basin ........................................................................................... 11.1
4' x 4' Acid Neutralizaton Tank - 350 Gallon .................................................... 11.2
15" Sample Well .............................................................................................. 11.3
27" x 24" Sample Well ..................................................................................... 11.4
250 Gallon Grease Interceptor (D/FW) ............................................................ 11.5
500 Gallon Grease Interceptor (D/FW) ............................................................ 11.6
1,000 Gallon Grease Interceptor (D/FW) ......................................................... 11.7
1,500 Gallon Grease Interceptor (D/FW) ......................................................... 11.8
2,000 Gallon Grease Interceptor (D/FW) ......................................................... 11.9
3,000 Gallon Grease Interceptor (D/FW) ....................................................... 11.10
4,000 Gallon Grease Interceptor (D/FW) ....................................................... 11.11
5,000 Gallon Grease Interceptor (D/FW) ....................................................... 11.12
6,000 Gallon Grease Interceptor (D/FW) ....................................................... 11.13
7,000 Gallon Grease Interceptor (D/FW) ....................................................... 11.14
8,000 Gallon Grease Interceptor (D/FW) ....................................................... 11.15
9,000 Gallon Grease Interceptor (D/FW) ....................................................... 11.16
10,000 Gallon Grease Interceptor (D/FW) ..................................................... 11.17
500 Gallon Grease Interceptor - Austin ......................................................... 11.18
1,000 Gallon Grease Interceptor - Austin ...................................................... 11.19
1,500 Gallon Grease Interceptor - Austin ...................................................... 11.20
2,000 Gallon Grease Interceptor - Austin ...................................................... 11.21
500 Gallon Grease Interceptor - Waco .......................................................... 11.22
1,000 Gallon Grease Interceptor - Waco ....................................................... 11.23
1,500 Gallon Grease Interceptor - Waco ....................................................... 11.24
250 Gallon Sand / Oil Interceptor (D/FW) ...................................................... 11.25
500 Gallon Sand / Oil Interceptor (D/FW) ...................................................... 11.26
1,150 Gallon Sand / Oil Interceptor (D/FW) ................................................... 11.27
1,500 Gallon Sand / Oil Interceptor (D/FW) ................................................... 11.28
(Interceptors continued on next page.)

TITLE PLANT STATE .


SECTION PAGE DATE

Grand Prairie
Index Houston TX 1.7 01-25-10
Waco HEIDELBERGCEMENT Group
Topic Section.Page
11. Interceptors (continued) ................................................................................... 11.0
2,000 Gallon Sand / Oil Interceptor (D/FW) ................................................... 11.29
3,000 Gallon Sand / Oil Interceptor (D/FW) ................................................... 11.30
4,000 Gallon Sand / Oil Interceptor (D/FW) ................................................... 11.31
5,000 Gallon Sand / Oil Interceptor (D/FW) ................................................... 11.32
500 Gallon Sand/Oil Interceptor - Waco ........................................................ 11.33
1,000 Gallon Sand/Oil Interceptor - Waco ..................................................... 11.34
250 GallonOil Interceptor (D/FW) .................................................................. 11.35
500 GallonOil Interceptor (D/FW) .................................................................. 11.36
1,000 GallonOil Interceptor (D/FW) ............................................................... 11.37
12. Vaults ................................................................................................................ 12.0
North Texas Meter Vaults .............................................................................. 12.a
Dallas DC Meter Vault .................................................................................. 12.a.1
Dallas FM Meter Vault .................................................................................. 12.a.2
4' x 8' Meter Vault ......................................................................................... 12.a.3
3" thru 10" Double DectorCheck Backflow Preventer in Precast
Concrete Vault (w/ Slab Top) ....................................................... 12.a.4
4" thru 10" Double Detector Backflow Preventer in Precast
Concrete Vault w/FDC ................................................................. 12.a.5
3" & 4" Compound Meter Vault ..................................................................... 12.a.6
3", 4" & 6" Compound Meter Vault ................................................................ 12.a.7
3", 4" & 6" Turbine Meter Vault ..................................................................... 12.a.8
3" & Larger Domestic Meter and Double-Check Assembly .......................... 12.a.9
3" & Larger Turbine Meter and Double-Check Assembly ........................... 12.a.10
4" Meter Vault ............................................................................................. 12.a.11
3" thru 10" Double Detector Check Backflow Preventer in Precast
Concrete Vault w/ Metal Top ....................................................... 12.a.12
3" thru 10" Double Check Backflow Preventer in Precast Concrete Vault .. 12.a.13
4" thru 10" Double Check Backflow Preventer w/PIV & FDC in Precast
Concrete Vault .............................................................................12.a.14
4" thru 10" Double Dector Check Backflow Preventer in Precast
Concrete Vault w/PIV & FDC ......................................................12.a.15
8" Compound Meter Vault ........................................................................... 12.a.16
Houston Area Meter Vaults ...........................................................................12.b
City of Houston 3" thru 6" Domestic Water Compound Meter in Precast
Concrete Vault ............................................................................ 12.b.1
3" thru 8" Domestic Compound Water Meter in Precast Concrete Vault ...... 12.b.2
City of Houston 4" thru 10" Combination Fire and Domestic Meter .............. 12.b.3
4" thru 10" Combination Fire & Domestic Water Meter ................................ 12.b.4
3" thru 10" Fireline Meter Assembly ............................................................. 12.b.5
3" thru 10" Fire Service Turbine Meter ......................................................... 12.b.6
4' x 4' Fiber Optic Manhole ........................................................................... 12.b.7

TITLE PLANT STATE .


SECTION PAGE DATE

Grand Prairie
Index Houston TX 1.8 01-25-10
Waco HEIDELBERGCEMENT Group
Topic Section.Page
12. Vaults (continued) ............................................................................................ 12.0
Central Texas Meter Vaults ........................................................................... 12.c
Meter Box - Residential ................................................................................ 12.c.1
Meter Vault - Manhole .................................................................................. 12.c.2
5' x 5' Meter Vault ......................................................................................... 12.c.3
7.5' x 4.5' Meter Vault ................................................................................... 12.c.4
6' x 12' Meter Vault (W/ 36" x 48" Hatch) ...................................................... 12.c.5
6' x 12' Meter Vault (W/ 30" x 30" Hatch) ...................................................... 12.c.6
7' x 5' Meter Vault ......................................................................................... 12.c.7
8' x 12' Meter Vault ....................................................................................... 12.c.8
10' x 12' Meter Vault ..................................................................................... 12.c.9
10' x 15' Meter Vault ................................................................................... 12.c.10
Service Box - City of Austin ........................................................................ 12.c.11
36" Pullbox - Traffic Type - City of Austin .................................................... 12.c.12
36" Pullbox - Non-Traffic Type - City of Austin ............................................ 12.c.13
48" Pullbox - Traffic Type - City of Austin .................................................... 12.c.14
48" Pullbox - Non-Traffic Type - City of Austin ............................................ 12.c.15
13. Septic Tanks ..................................................................................................... 13.0
500 Gallon Septic Tank .................................................................................... 13.1
750 Gallon Septic Tank .................................................................................... 13.2
1,000 Gallon Septic Tank ................................................................................. 13.3
1,250 Gallon Septic Tank ................................................................................. 13.4
1,500 Gallon Septic Tank ................................................................................. 13.5
500 Gallon Pump Tank .................................................................................... 13.6
750 Gallon Pump Tank .................................................................................... 13.7
1,000 Gallon Pump Tank ................................................................................. 13.8
1,250 Gallon Pump Tank ................................................................................. 13.9
1,500 Gallon Pump Tank ............................................................................... 13.10
3-Chamber NORWECO System ................................................................... 13.11
4-Chamber NORWECO System ................................................................... 13.12
Jet Tank ......................................................................................................... 13.13
14. Miscellaneous .................................................................................................. 14.0
150 & 300 Gallon Water Troughs .................................................................... 14.1
300 & 500 Gallon Water Troughs .................................................................... 14.2
Concrete Liner Box .......................................................................................... 14.3
Single Crypt ..................................................................................................... 14.4
Concrete Cattleguard ...................................................................................... 14.5

TITLE PLANT STATE .


SECTION PAGE DATE

Grand Prairie
Index Houston TX 1.9 01-25-10
Waco HEIDELBERGCEMENT Group
Topic Section.Page

15. TXDOT ............................................................................................................... 15.0


Type "C" Curb Inlet w/Type "E" Extension - 5', 10' & 15' Options .................... 15.1
Type "C "Curb Inlet w/Type "E" Extension, Stage 1 - 5', 10' & 15' Options ..... 15.2
Type "IR" Curb Inlet, Stage 1, 36" Pipe & Smaller ....................................... 15.3
Type "IIR" Curb Inlet, Stage 1, 36" Pipe & Smaller ...................................... 15.4
Type "IR" Curb Inlet, Stage 1, 42" - 60" Pipe ........................................... 15.5
Type "IIR" Curb Inlet, Stage 1, 42" - 60" Pipe .......................................... 15.6
Type "I" Curb Inlet ............................................................................................ 15.7
Type "II" Curb Inlet ........................................................................................... 15.8
Type "I" Curb Inlet, Stage 1 ............................................................................. 15.9
Type "II" Curb Inlet, Stage 1 .......................................................................... 15.10
Type "I" Curb Inlet, w/Type "I-E Extension - San Antonio District .................. 15.11
Type "II" Curb Inlet, w/Type "II-E Extension - San Antonio District ................ 15.12
Type "III" Curb Inlet, 3' - 8" x 20' - San Antonio District ................................. 15.13
Type "V" Curb Inlet, 3' - 8" x 30' - San Antonio District .................................. 15.14
Type "II" Curb & Grate Inlet, Stage 1, 5' - 10' & 15' Options .......................... 15.15
Type "SS" Curb & Grate Inlet, Stage 1, 5' - 10' & 15' Options ....................... 15.16
Type "I" Curb Inlet, Stage 1 - 5' - 0" ............................................................... 15.17
Type "I" Curb Inlet, Stage 1 - 10' - 0" ............................................................. 15.18
Type "I" Curb Inlet, Stage 1 - 15' - 0" ............................................................. 15.19
Type "I" Curb Inlet, Stage 1 - 20' - 0" ............................................................. 15.20
Type "CI" Curb Inlet w /Extension, 5' - 10' & 15' Options............................... 15.21
Type "II-G" Curb Inlet, 1-Grate, Stage 1 - 4' - 9" x 5' - 0" ............................... 15.22
Type "II-G" Curb Inlet, 2-Grate, Stage 1 - 10' - 6" x 5' - 0" ............................. 15.23
Type "A" Manhole - 6' - 0" Max. x 6' - 0" Max. ............................................... 15.24
Type "M" Manhole - 6' - 0" Max. x 6' - 0" Max................................................ 15.25
Type "I" Manhole - 3' - 0" x 3' - 0" .................................................................. 15.26
Type "II" Manhole - 3' - 0" x 3' - 0" ................................................................. 15.27
Type "2" Manhole .......................................................................................... 15.28
Type "I" Manhole - 6' - 0" Max. x 6' - 0" Max.................................................. 15.29
Type "1" Drop Inlet - 3' - 0" x 3' - 0" ............................................................... 15.30
Type "3" Drop Inlet - 3' - 0" x 8' - 0" ............................................................... 15.31
Type "H" Grate Inlet ....................................................................................... 15.32
Type "AD" Grate Inlet - 2' - 6" x 2' - 6" ........................................................... 15.33
Type "AAD" Grate Inlet - 2' - 6" x 5' - 0" ......................................................... 15.34
(TXDOT continued on next page.)

TITLE PLANT STATE .


SECTION PAGE DATE

Grand Prairie
Index Houston TX 1.10 01-25-10
Waco HEIDELBERGCEMENT Group
Topic Section.Page

15. TXDOT (Continued) ........................................................................................... 15.0


Type "I" Drop Inlet, 1-Grate - 3' - 0" x 3' - 6" .................................................. 15.35
Type "I" Drop Inlet, 2-Grate - 3' - 0" x 7' - 0" .................................................. 15.36
Type "I" Drop Inlet, 3-Grate - 3' - 0" x 10' - 6" ................................................ 15.37
Type "II" Drop Inlet - 3' - 0" x 4' - 10" ............................................................. 15.38
Type III Drop Inlet - 3' - 6" x 3' - 6', San Antonio ............................................ 15.39
Type "AZR" Inlet, 1-Grate - 2' - 0" x 3' - 9" ..................................................... 15.40
Type "AZR" Inlet, 2-Grate - 2' - 0" x 8' - 6 1/2" ............................................... 15.41
Type "AZ" Inlet, 1-Grate - 2' - 0" x 3' - 9" ....................................................... 15.42
Type "C" Drop Inlet, 1-Grate - 2' - 0" x 3' - 0"................................................. 15.43
Type "C" Drop Inlet, 2-Grate - 2' - 0" x 5' - 4"................................................. 15.44
Type "C" Drop Inlet, 3-Grate - 2' - 0" x 7' - 8"................................................. 15.45
Type "G" Drop Inlet, 1-Grate - 2' - 0" x 3' - 0" ................................................ 15.46
Type "G" Drop Inlet, 2-Grate - 2' - 0" x 5' - 4" ................................................ 15.47
Type "XXII" Drop Inlet - 3' - 6" x 3' - 6"........................................................... 15.48
Type "XXIII" Drop Inlet - 3' - 6" x 5' - 6".......................................................... 15.49
Type "XXIV" Drop Inlet - 3' - 6" x 7' - 6" ......................................................... 15.50
Type "D" Drop Inlet, 2-Grate - 1' - 6" x 6' - 4"................................................. 15.51
Type "W-1" Drop Inlet - 5' - 0" x 6' - 0" ........................................................... 15.52
Type "W-2" Drop Inlet - 5' - 0" x 12' - 0" ......................................................... 15.53
Type "W-3" Drop Inlet - 5' - 0" x 18' - 0" ......................................................... 15.54
Type "X-1" Traffic Inlet - 2' - 6" x 6' - 0" .......................................................... 15.55
Type "X-2" Traffic Inlet - 2' - 6" x 12' - 0" ........................................................ 15.56
Type "X-3" Traffic Inlet - 2' - 6" x 18' - 0" ........................................................ 15.57
Type "X-4" Traffic Inlet - 2' - 6" x 24' - 0" ........................................................ 15.58
Type "Y-1" Drop Inlet - 2' - 6" x 6' - 0" ............................................................ 15.59
30" x 12' - 2" Drop Inlet, Type Y-2, San Antonio ............................................ 15.60
TX DOT Stage 1 Inlets with Variable Depths ................................................. 15.61
Fort Worth DOT Type S1-2 Stage 1 Inlets with Variable Depths ................... 15.62
Fort Worth DOT Type SS1-2 Stage 1 Inlets with Variable Depths ................. 15.63
Fort Worth DOT Type U Stage 1 Inlets with Variable Depths ........................ 15.64
Type "E" Inlet Top for 3' x 3' Junction Box ..................................................... 15.65
3' x 5' Junction Box with Variable Depths ...................................................... 15.66
3' x 5' Junction Box with Variable Depths and w/"C" Type Top ...................... 15.67
2' - 0" x 3' - 0" x 60" Type 1 Ground Box ....................................................... 15.68
3' - 0" x 3' - 0" x 60" Type 2 Ground Box ....................................................... 15.69
1' x 2' x 22" Type 1 Pull Box .......................................................................... 15.70
2' x 3'x 3' Type 2 Pull Box .............................................................................. 15.71

TITLE PLANT STATE .


SECTION PAGE DATE

Grand Prairie
Index Houston TX 1.11 01-25-10
Waco HEIDELBERGCEMENT Group
Topic Section.Page

15. TXDOT (Continued) ........................................................................................... 15.0


2' x 3' x 22" Type 1 Pull Box ......................................................................... 15.72
4' x 4' x 3' - 6" I.D. Ground Box ..................................................................... 15.73
4' x 4' x 3' (I.D.) Type "J" Ground Box ........................................................... 15.74
2' x 2' x 2' (I.D.) Type 1 Handhole ................................................................. 15.75
3' x 3' x 3' Type B Junction Box ..................................................................... 15.76
16. Electric / Telephone .......................................................................................... 16.0
2' - 0" x 3' - 0" x 24" Type "AS" Junction Box .................................................. 16.1
3' - 0" x 5' - 0" x 36" Type "DS" Junction Box ................................................. 16.2
3' x 5' x 36" Handhole ...................................................................................... 16.3
4' x 6' x 6' Electric Manhole ............................................................................. 16.4
4' x 8' x 6' Telephone Manhole ......................................................................... 16.5
6' x 12' x 7' Electrical Manhole......................................................................... 16.6
6' x 12'' Electrical Manhole with Variable Depths ............................................ 16.7
6' x 12'' Electrical Manhole with Variable Riser ............................................... 16.8
24" x 24" Cable Marker .................................................................................... 16.9
6' x 12' x 7' Meter Vault .................................................................................. 16.10
3' x 5' x 36" Handhole with Slab Bottom ........................................................ 16.11
4' x 8' x 48" Handhole with Slab Bottom ........................................................ 16.12
6' x 8' x 7' Electrical Manhole......................................................................... 16.13
4' x 4' Pull Box ............................................................................................... 16.14
4' x 5' Pull Box ............................................................................................... 16.15
7' x 7' x 7' Manhole ........................................................................................ 16.16
8' x 8' Manhole ............................................................................................... 16.17
3' x 3' Standard Pull Box with Variable Depths .............................................. 16.18
3' x 3'' 1-Piece Manhole ................................................................................ 16.19
4' x 4' Pull Box w/ Slab Top ............................................................................ 16.20
4' x 6' x 48" Handhole with Slab Bottom ........................................................ 16.21
6' x 6' Manhole ............................................................................................... 16.22
8' x 10' Standard Manhole ............................................................................. 16.23
10' x 10' Manhole ........................................................................................... 16.24
2' x 3' Pull Box ............................................................................................... 16.25
2' x 3' Pull Box w/ Steel Hatch ....................................................................... 16.26
5' x 5' x 3' Type A Junction Box ...................................................................... 16.27
5' x 5' x 5' Manhole - Dart Type "C" ............................................................... 16.28
4' x 4' x 6' Manhole ........................................................................................ 16.29
5' x 5' x 7' Manhole - Dart Type "B" ............................................................... 16.30
20' x 20' Pull Box ........................................................................................... 16.31
5' x 5' x 7' Manhole - Dart Type "B3" ............................................................. 16.32
Note:
* - Page not numbered but in sequence as shown.
TITLE PLANT STATE .
SECTION PAGE DATE

Grand Prairie
Index Houston TX 1.12 01-25-10
Waco HEIDELBERGCEMENT Group
Topic Section.Page
17. Electric / Telephone .......................................................................................... 17.0
5' x 5' x 10' Manhole - Dart Type "D3" ........................................................... 16.33
5' x 5' x 5' Manhole ........................................................................................ 16.34
5' x 5' Manhole with Varible Depths ............................................................... 16.35
E.V.C. Vault #V-4866 ..................................................................................... 16.36
E.V.C. Top Slab #LL-4872 ............................................................................. 16.37
E.V.C. Top Slab #LT-4872 .............................................................................. 16.38
E.V.C. Top Slab #LT-7878-H .......................................................................... 16.39
E.V.C. Vault #V-9696 ..................................................................................... 16.40
E.V.C. Vault #V-7296 ..................................................................................... 16.41
E.V.C. Top Slab #LC-8496 ............................................................................. 16.42
E.V.C. Top Slab #LT-120120-H ...................................................................... 16.43
E.V.C. Vault #V-7214484 ............................................................................... 16.44
E.V.C. Top Slab #LT-72144 ............................................................................ 16.45
E.V.C. Top Slab #LSG-9696 .......................................................................... 16.46
E.V.C. Top Slab #LC-8496 with Access Hatch ............................................... 16.47
E.V.C. Top Slab #LJVSG-9696 ...................................................................... 16.48
E.V.C. Top Slab #LJVC-9696 - Jct. for 2 ea. Sectionalizing
Enclosures & 1 Transformer ................................................. 16.49
E.V.C. Top Slab #LJV3-9696 - Jct. for 3 ea. Sectionalizing Enclosures ........ 16.50
4' x 4' x 6' Pull Box ......................................................................................... 16.51
4' x 4' x 7' Pull Box ......................................................................................... 16.52
17. Engineering ...................................................................................................... 17.0
ASTM C-76 & ASTM C655 Comparison .......................................................... 17.1
Fill Height Table, Type 2 Bedding: 1' - 15' Fill Height....................................... 17.2
Fill Height Table, Type 2 Bedding: 16' - 30' Fill Height..................................... 17.3
Fill Height Table, Type 2 Bedding: 31' - 45' Fill Height..................................... 17.4
Fill Height Table, Type 3 Bedding: 1' - 18' Fill Height....................................... 17.5
Fill Height Table, Type 3 Bedding: 19' - 35' Fill Height..................................... 17.6
Fill Height Table, Type 4 Bedding: 1' - 15' Fill Height....................................... 17.7
Fill Height Table, Type 4 Bedding: 16' - 23' Fill Height..................................... 17.8
TXDOT Equivalents per 464-2 ........................................................................ 17.9
Tables - Full Flow Constants ............................................................ 17.10 - 17.14
Design Red Lights - (Project Check List) ....................................................... 17.15

TITLE PLANT STATE .


SECTION PAGE DATE

Grand Prairie
Index Houston TX 1.13 01-25-10
Waco HEIDELBERGCEMENT Group
Topic Section.Page
17. Engineering ...................................................................................................... 17.0

Standard Hole Diameters .............................................................................. 17.16


Instructions & Examples for Pipe Half Angle Table ........................................ 17.17
Instructions & Examples for Pipe Half Angle Table (cont.) ............................ 17.18
Pipe Half Angle Diagram ............................................................................... 17.19
Pipe Half Angle Table .................................................................................... 17.20
Maximum Pipe Angle Tables (Instructions/Examples) ................................... 17.21
Pipe Angle Diagram - Flat Wall Structures .................................................... 17.22
Maximum Pipe Angle - Flat Wall Structures Table ......................................... 17.23
Rebar Chart ................................................................................................... 17.24
Welded Wire Mesh Chart .............................................................................. 17.25
Casting Specifications ................................................................................... 17.26
Typical Reinforcing Details ............................................................................ 17.27
Radius Pipe - ACPA Design Data 21 ............................................................. 17.28
Specifications Applicable to Concrete Pipe and
Associated Precast Concrete Products ............................................ 17.29 - 17.30
ACPA Design Data (Reference publications) ............................................. 17.n/a*

Note:
* - Page not numbered but in sequence as shown.
TITLE PLANT STATE .
SECTION PAGE DATE

Grand Prairie
Index Houston TX 1.14 01-25-10
Waco HEIDELBERGCEMENT Group
Reinforced Concrete Pipe

O.D. Bell
Wall
I.D.

Laying Length

Basic Dimensions
I.D. Laying Wall Bell Aprox.
Pipe Lenght Thickness Diameter Wt / Ft
(Inches) (Feet) (Inches) (Inches) (Pounds)

12 4-6 2 16 92
15 4-6 2 19 111
18 4-6-8 2 1/2 23 168
21 4-6-8 2 3/4 26 1/2 214
24 4-6-8 3 30 265
27 4-6-8 3 1/4 33 1/2 322
30 4-6-8 3 1/2 37 384
33 4-6-8 3 3/4 40 1/2 451
36 4-6-8 4 44 524
39 * 4 1/4 47 1/2 614
42 4-6-8 4 1/2 51 685
45 * 4 3/4 54 1/2 789
48 4-6-8 5 58 885
51 * 5 1/4 61 1/2 986
54** 4-6-8 5 1/2 65 1,092
60** 4-6-8 6 72 1,322
66** 4-6-8 6 1/2 79 1,573
72 4-6-8 7 86 1,846
78 * * * *
84 * * * *
90 * * * *
96 * * * *
108 * * * *
120 * * * *
Note:
Conforms to current ASTM C-76 or C-655 specifications
for reinforced concrete pipe.
-No Scale-
* - - Wall
Dimensions vary; contact manufacturer.
C available in some market areas.
All dimensions subject to allowable
** specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Grand Prairie
Tongue and Groove Pipe Houston TX 2.1 01-25-10
HEIDELBERGCEMENT Group
Reinforced Concrete Pipe

Wall

Rise
Jt.
Wall

L Jt.
Span

Side View End View

Pipe Dimensions
Rd. Equiv Rise Span Wall Jt. Joint Weight
Pipe Size Length
(in.) (in.) (in.) (in.) (in.) (ft.) (Lb./ Ft.)
15 11 18 3 2 1/4 8 188
18 13 1/ 22 1/
3 8 2 1/4 8 233
2
24 18 28 1/ 3 1/2 2 3/ 8 325
2 4

30 22 1/2 36 1/4 3 1/2 3 8 392


36 26 5/8 43 3/4 4 3 1/2 8 537
42 31 5/16 51 1/8 4 1/2 3 1/2 8 696

48 36 58 1/2 5 3 1/2 8 885


54 40 65 1/
5 2 5 8 1,079
60 45 73 6 5 8 1,333

72 54 88 7 6 8 1,856
84 62 5/ 102 8 6 1/ 6 2,350
8 8
96 77 3/ 122 9 7 6 3,330
8

-No Scale-
All dimensions subject to allowable
specification tolerances.
TITLE PLANT STATE .
SECTION PAGE DATE

Grand Prairie
Reinforced Concrete Arch Pipe, 15" - 96" Houston TX 2 .2 01-25-10
HEIDELBERGCEMENT Group
Reinforced Concrete Pipe

O
ut
si
de
D
In
ia
si
m
de
et
er
D
L. ia
L. m
l et
er
Bel

.
Spigot L.L.

in
"M p.
12 Ty
12" Min.
Typ.

Plan View

Note:
Up to 60" RCP standard bend angles are 15, 30, 45 & 90.
-No Scale-
Contact manufacturer above 60". All dimensions subject to allowable
Other angles are available upon request. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Tongue and Groove Pipe Grand Prairie


Houston TX 2 .3 01-25-10
Typical Bend HEIDELBERGCEMENT Group
Reinforced Concrete Pipe

12"

Spigot L.L.
Typ.

"A" "A"
Standard Joint Length

Branch L.L.
C Branch

Bell L.L.

Plan View

I.D.

ll
Wa

Section A-A

-No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Tongue and Groove Pipe Grand Prairie


Houston TX 2.4 01-25-10
Typical Horizontal or Vertical Concentric Tee HEIDELBERGCEMENT Group
Reinforced Concrete Pipe

12"

Spigot L.L.
Typ.

"A" "A"
Standard Joint Length

Branch L.L.
C Branch

Bell L.L.

Plan View

As Req'd.

I.D.

ll
Wa

Section A-A

-No Scale-
Note: All dimensions subject to allowable
Tops even shown; other configurations available as required. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Tongue and Groove Pipe Grand Prairie


2.5
Houston TX 01-25-10
Typical Horizontal or Vertical Eccentric Tee HEIDELBERGCEMENT Group
Reinforced Concrete Pipe

Spigot L.L.
Standard Joint Length

Br
an
ch
L.
L.
Bell L.L.

C
12 Br
"T an
yp ch
.

Plan View

I.D.

ll
Wa

Approximate Section

-No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Tongue and Groove Pipe Grand Prairie


Houston TX 2 .6 01-25-10
Typical Concentric Wye HEIDELBERGCEMENT Group
Reinforced Concrete Pipe

Spigot L.L.

Standard Joint Length

Br
an
ch
L.
L.

Bell L.L.

C
12 Br
"T an
yp ch
.

Plan View

As Req'd.

I.D.

ll
Wa

Approximate Section

-No Scale-
Note: All dimensions subject to allowable
Tops even shown; other configurations available as required. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Tongue and Groove Pipe Grand Prairie


TX 2 .7 01-25-10
Typical Eccentric Wye Houston
HEIDELBERGCEMENT Group
Reinforced Concrete Pipe

Pipe Diameter
Downstream

Upstream
Pipe Dia.
Plan View
Pipe Diameter
Downstream

Upstream
Pipe Dia.
Flow Flow
Line Line
Elevation - Bottoms Even
Pipe Diameter
Downstream

Upstream
Pipe Dia.

Flow
Flow
Line
Line
Elevation - Centerline Even
Pipe Diameter

Upstream
Pipe Dia.
Downstream

Flow
Flow Line
Line
-No Scale-
Elevation - Tops Even All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Tongue and Groove Pipe Grand Prairie


2.8
Houston
TX 01-25-10
Reducers - Option 1 HEIDELBERGCEMENT Group
Reinforced Concrete Pipe

6", 8" or 12"


as Required

Pipe Diameter
Upstream

Downstream
Pipe Spigot Upstream
Pipe Bell

Reducing Stopper

Note: -No Scale-


Reduction may be centered or All dimensions subject to allowable
offset as required. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Tongue and Groove Pipe Grand Prairie


TX 2.9 01-25-10
Reducers - Option 2 Houston HEIDELBERGCEMENT Group
Reinforced Concrete Pipe

A-1 (Straight Pipe - Closed Joint) Radius


B-1 (Radius Pipe - Closed Joint)

Maximum Pull
of Joint is Half of
Tongue Length
**

A-2 (Straight Pipe + Pulled Joint) Radius B-2 (Radius Pipe + Pulled Joint)
Radius

Standard Radius Design Data


I.D. Joint A-2 B-1 B-2
Pipe Lenght Radius Radius Radius
(Inches) (Feet) (Feet) (Feet) (Feet)

18 4 90 65 35
21 4 110 65 40
24 4 140 65 40
27 4 135 65 40
30 4 135 65 45
33 4 140 65 45
36 4 120 65 45
39 * * * *
42 4 125 75 45
45 * * * *
48 4 125 75 45
51 * * * *
54 4 120 85 45
60 4 125 85 50
66 4 125 80 50
72 4 120 80 45
78 * * * *
84 * * * *
90 * * * *
96 * * * *
102 * * * *
108 * * * *
120 * * * *

Note:
- For special radius design contact manufacturer.
-No Scale-
* - Dimensions vary; contact manufacturer. All dimensions subject to allowable
specification tolerances.
** - Joint opening subject to local specifications.
TITLE PLANT STATE .
SECTION PAGE DATE

Grand Prairie
Tongue and Groove Radius Pipe TX 2.10 01-25-10
Houston
HEIDELBERGCEMENT Group
Reinforced Concrete Pipe

Wall
Wall
12" thru 78" 60" thru 120"
Packerhead Joint Diameter Hydropak Joint Diameter

Manufacturer Estimated Quantities


I.D. Pre-Formed Mastic
Pipe Wall
(Inches) (Inches) Size Cu. In. / Ft. Pcs. / Jt. Gal./Jt.

12 B 2 3/ " x 2'-6" 5.60 1.5 0.21


4
15 SP 2 3/ " x 2'-6" 5.60 1.8 0.26
4
18 B 2 1/2 3/ "
4 x 2'-6" 5.60 2.1 0.38
21 B 2 3/4 3/ "
4 x 2'-6" 5.60 2.5 0.47
24 B 3 3/ " x 2'-6" 5.60 2.8 0.53
4
27 B 3 1/4 3/ "
4 x 2'-6" 5.60 3.1 0.65
30 B 3 1/2 1" x 3'-6" 11.28 3.5 0.79
33 B 3 3/4 1" x 3'-6" 11.28 3.9 0.95
36 B 4 1" x 3'-6" 11.28 4.2 1.14
39 B 4 1/4 1 1/2" x 3'-6" 22.50 3.3 1.36
42 B 4 1/2 1 1/2" x 3'-6" 22.50 3.5 1.62
45 B 4 3/4 1 1/2" x 3'-6" 22.50 3.7 1.77
48 B 5 1 1/2" x 3'-6" 22.50 4.0 1.97
51 B 5 /4 1 1/2" x 3'-6"
1 22.50 4.2 2.20
54 B 5 1/2 1 1/2" x 3'-6" 22.50 4.5 2.46
60 B 6 1 1/2" x 3'-6" 22.50 5.0 2.92
60 C 6 /4 1 3/4" x 3'-6"
3 36.00 5.0 3.55
66 B 6 1/2 2" x 3'-6" 42.00 5.5 3.60
66 C 7 1/4 1 3/4" x 3'-6" 36.00 5.5 3.87
72 B 7 2" x 3'-6" 42.00 5.9 4.29
72 C 7 3/4 1 3/4" x 3'-6" 36.00 5.9 4.25
78 C 8 1/4 1 3/4" x 3'-6" 36.00 6.4 4.89
84 C 8 3/4 1 3/4" x 3'-6" 36.00 6.9 5.54
90 C 9 1/4 1 3/4" x 3'-6" 36.00 7.4 6.40
96 C 9 3/4 1 3/4" x 3'-6" 36.00 7.8 6.76
102 SP 11 1/4 1 3/4" x 3'-6" 36.00 8.4 7.49
108 C 10 3/4 1 3/4" x 3'-6" 36.00 8.8 8.17
120 A 10 2" x 3'-6" 42.00 9.7 9.55
120 C 11 3/4 2" x 3'-6" 42.00 9.7 9.55

-No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Tongue and Groove Pipe Grand Prairie


TX 2.11 01-25-10
Joint Material Houston HEIDELBERGCEMENT Group
Reinforced Concrete Pipe

O.D. Bell
Wall
Laying Length
I.D.

Basic Dimensions
I.D. Laying Wall Bell Aprox.
Pipe Lenght Thickness Diameter Wt. / Ft.
(Inches) (Feet) (Inches) (Inches) (Pounds)

12 6 2 19 1/8 99
15 6 2 1/4 22 3/8 135
18 8 2 1/2 25 3/8 176

21 8 2 3/4 29 5/8 235


24 8 3 33 3/8 279
27 8 3 1/4 36 3/4 336

30 8 3 1/2 40 1/8 399


33 8 3 3/4 43 3/4 469
36 8 4 47 1/2 545

42 8 4 1/2 57 3/4 768


48 8 5 63 3/4 948
54 8 6 1/4 69 3/4 1,292

60 8 6 3/4 75 5/8 1,528


66 8 7 1/4 815/8 1,786

Note:
Conforms to current ASTM C-76 specification for

reinforced concrete pipe. For other specification(s) -No Scale-


requirements, contact manufacturer. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE SECTION PAGE . DATE

Grand Prairie
Confined Groove Joint, 12" - 66" TX 3 .1 01-25-10
Houston
HEIDELBERGCEMENT Group
Reinforced Concrete Pipe

O.D. Pipe
Wall
Laying Length
I.D.

Basic Dimensions
I.D. Laying Wall O.D. Aprox.
Pipe Lenght Thickness Pipe Wt / Ft
(Inches) (Feet) (Inches) (Inches) (Pounds)

42* 8 5 1/4 52 1/2 819


48* 8 5 3/4 59 1/2 1,012
54* 8 6 1/4 66 1/2 1,256

60* 8 6 3/4 73 1/2 1,470


66* 8 7 1/4 80 1/2 1,735
72 8 7 3/4 87 1/2 2,063

78 8 8 1/4 94 1/2 2,391


84 8 8 3/4 101 1/2 2,727
90 8 9 1/4 108 1/2 3,084

96 8 9 3/4 115 1/2 3,464


102 8 11 1/4 124 1/2 4,279
108 8 10 3/4 129 1/2 4,289
120 8 11 3/4 143 1/2 5,201

Note:
* - Check for availability in your market area.
Conforms to current ASTM C-76 specification for
reinforced concrete pipe. For other specification(s)
-No Scale-
requirements, contact manufacturer. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE SECTION PAGE . DATE

Grand Prairie
Confined Groove Joint, 42" - 120" TX 3.2 01-25-10
Houston HEIDELBERGCEMENT Group
Reinforced Concrete Pipe

O.D. Bell
Wall
Laying Length
I.D.

Basic Dimensions
I.D. Laying Wall Bell Aprox.
Pipe Lenght Thickness Diameter Wt / Ft
(Inches) (Feet) (Inches) (Inches) (Pounds)

12 6 2 19 1/8 101
12 8 2 3/4 19 5/8 142
15 6 2 1/4 22 3/8 138
15 8 3 23 1/8 188
18 8 2 1/2 25 7/8 178
18 8 3 1/4 26 5/8 240
21 8 2 3/4 29 5/8 228
24 8 3 33 3/8 282
24 8 3 3/4 32 5/8 355
27 8 3 1/4 36 3/4 343
30 8 3 1/2 40 1/8 406
30 8 4 1/4 39 1/2 494
33 8 3 3/4 43 3/4 481
36 8 4 47 1/2 559
42 8 4 1/2 57 3/4 768
48 8 5 63 3/4 948
54 8 6 1/4 69 3/4 1,292
60 8 6 3/4 75 5/8 1,528
66 8 7 1/4 815/8 1,786

Note:
Contact your Hanson Representative for availability in your area.

Conforms to current ASTM C-76 specification for


-No Scale-
reinforced concrete pipe. For other specification(s) All dimensions subject to allowable
requirements, contact manufacturer. specification tolerances.

TITLE PLANT STATE SECTION PAGE . DATE

Grand Prairie
Single Offset Joint, 12" - 66" TX 3.3 01-25-10
Houston
HEIDELBERGCEMENT Group
Reinforced Concrete Pipe

O.D. Pipe
Wall
Laying Length
I.D.

Basic Dimensions
I.D. Laying Wall O.D. Aprox.
Pipe Lenght Thickness Pipe Wt / Ft
(Inches) (Feet) (Inches) (Inches) (Pounds)

36 8 4 3/4 45 1/2 642


42 8 5 1/4 52 1/2 823
48 8 5 3/4 59 1/2 1,025

54 8 6 1/4 66 1/2 1,249


60 8 6 3/4 73 1/2 1,494
66 8 7 1/4 80 1/2 1,761

72 8 7 3/4 87 1/2 2,063


78 8 8 1/4 94 1/2 2,391
84 8 8 3/4 101 1/2 2,727

90 8 9 1/4 108 1/2 3,084


96 8 9 3/4 115 1/2 3,464
102 8 11 1/4 124 1/2 4,281

108 8 10 3/4 129 1/2 4,289


120 8 11 3/4 143 1/2 5,201

Note:
Contact local manufacturer for availability.

Conforms to current ASTM C-76 specification for

reinforced concrete pipe. For other specification(s)


-No Scale-
requirements, contact manufacturer. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE SECTION PAGE . DATE

Grand Prairie
Single Offset Joint, 36" - 120" TX 3.4 01-25-10
Houston HEIDELBERGCEMENT Group
Reinforced Concrete Pipe

O
ut
si
de
D
ia
m
et
In er
si
de
(a
tB
D
ia
el
m
. l)
et
L
L.
ll er
Be

.
yp
.T
in
"M
12
Spigot L.L.

12" Min.
Typ.

Confined Groove Joint Single Offset Joint

Plan View

Note:
Up to 60" RCP standard bend angles are 15, 30, 45 & 90.
-No Scale-
Contact manufacturer above 60". All dimensions subject to allowable
Other angles are available upon request. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Confined Groove or Single Offset Joint Grand Prairie


TX 3 .5 01-25-10
Typical Bend Houston HEIDELBERGCEMENT Group
Reinforced Concrete Pipe

Confined Groove Joint Single Offset Joint

12"
Preferred Min.

Spigot L.L.
"A" "A"
Standard Joint Length

Branch L.L.
Bell L.L. C Branch

Plan View

I.D.

ll
Wa

Section A-A -No Scale-


All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Confined Groove or Single Offset Joint Grand Prairie


TX 3 .6 01-25-10
Typical Concentric Tee Houston HEIDELBERGCEMENT Group
Reinforced Concrete Pipe

Confined Groove Joint Single Offset Joint

12" Preferred Min.

Spigot L.L.
"A" "A"
Standard Joint Length

Branch L.L.
C Branch
Bell L.L.

Plan View

As Req'd.

I.D.

ll
Wa

Section A-A -No Scale-


Note: All dimensions subject to allowable
Tops even shown; other configurations available as required. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Confined Groove or Single Offset Joint Grand Prairie


TX 3 .7 01-25-10
Typical Eccentric Tee Houston HEIDELBERGCEMENT Group
Reinforced Concrete Pipe

Confined Groove Joint Single Offset Joint

Spigot L.L.
Standard Joint Length

Br
an
ch
L.
L.
Bell L.L.

C
12 Br
"T an
ch
yp
.
Plan View

I.D.

ll
Wa

Approximate Section

-No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Confined Groove or Single Offset Joint Grand Prairie


TX 3.8 01-25-10
Typical Concentric Wye Houston HEIDELBERGCEMENT Group
Reinforced Concrete Pipe

Confined Groove Joint Single Offset Joint

Spigot L.L.
Standard Joint Length

Br
an
ch
L.L
.

Bell L.L.

CB
ran
ch

Plan View
Offset

.
I.D

ll
Wa

Approximate Section
-No Scale-
Note: All dimensions subject to allowable
Tops even shown; other configurations available as required.
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Confined Groove or Single Offset Joint Grand Prairie


TX 3.9 01-25-10
Typical Eccentric Wye Houston
HEIDELBERGCEMENT Group
Reinforced Concrete Pipe

Pipe Diameter
Downstream
See Detail "A"

Upstream
Pipe Dia.
Plan View
Pipe Diameter
Downstream

Upstream
Pipe Dia.

Flow Flow

Single Offset Joint


Line Line

Elevation - Bottoms Even


Pipe Diameter
Downstream

Upstream
Pipe Dia.

Confined Groove Joint


Flow
Flow
Line
Line

Elevation - Centerline Even


Pipe Diameter

Upstream
Pipe Dia.
Downstream

Detail "A"
Flow
Flow Line
Line

Elevation - Tops Even -No Scale-


All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Confined Groove or Single Offset Joint Grand Prairie


TX 3.10 01-25-10
Pipe Reducers - Option 1 Houston HEIDELBERGCEMENT Group
Reinforced Concrete Pipe

6", 8" or 12"


as Required

Single Offset Joint

Pipe Diameter
Upstream
Confined Groove Joint

Upstream
Pipe Bell

Downstream
Pipe Spigot
Reducing Stopper

Note: -No Scale-


Reduction may be centered or All dimensions subject to allowable
offset as required. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Confined Groove or Single Offset Joint Grand Prairie


3.11
Houston
TX 01-25-10
Pipe Reducers - Option 2 HEIDELBERGCEMENT Group
Reinforced Concrete Pipe

A-1 (Straight Pipe - Closed Joint) Radius


B-1 (Radius Pipe - Closed Joint)

Maximum Pull
of Joint is 1/2 inch
per A.S.T.M. 443

A-2 (Straight Pipe + Pulled Joint) Radius B-2 (Radius Pipe + Pulled Joint)
Radius

Standard Radius Design Data


I.D. Joint A-2 B-1 B-2
Pipe Lenght Radius Radius Radius
(Inches) (Feet) (Feet) (Feet) (Feet)

12 6 200 130 85
15 6 235 130 90
18 8 375 175 125
21 8 430 175 130
24 8 490 175 130
27 8 540 175 135
30 8 600 175 140
33 8 650 175 140
36 8 710 175 145
39 8 770 175 145
42 8 825 175 150
45 8 870 175 150
48 8 940 175 150
51 8 990 175 150
54 8 1070 175 155
60 8 1180 175 155
66 8 1295 175 160
72 8 1405 175 160
78 8 1520 175 160
84 8 1630 175 160
90 8 1740 175 165
96 8 1855 175 165
102 8 1965 175 165
108 8 2080 175 165
114 8 2190 175 165
120 8 3005 175 165
-No Scale-
Note: All dimensions subject to allowable
For special radius design contact manufacturer. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Grand Prairie
Gasketed Radius Pipe TX 3.12 01-25-10
Houston HEIDELBERGCEMENT Group
Reinforced Concrete Pipe

Step 1
Ensure that the bell and spigot of the pipe are clean, and free of debris.

Spigot Bell

Step 2
Using the lubricant supplied, lubricate the bell of the pipe throughly. Also lubricate
the gasket groove in the spigot of the pipe being joined.

Step 3
Place the gasket in the spigot groove. A well lubricated groove will automatically
equalize the tension in the gasket.

Spigot Bell

Step 4
When joining the pipe, align the spigot of the pipe with the bell of the pipe previously
placed. The gasket must contact the flared end of the bell around the complete
circumference.

Note: -No Scale-


Compliance with the above procedures helps ensure good joints. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Grand Prairie
Joining Procedure for "O" Ring Gaskets TX 3.13 01-25-10
Houston HEIDELBERGCEMENT Group
Reinforced Concrete Pipe

Step 1
Ensure that the bell and spigot of the pipe are clean, and free of debris.

Spigot Bell

Step 2
Place the self-lubricating gasket on the spigot end of the pipe, with the flap portion facing
up. The bottom of the gasket should rest firmly against the spigot shoulder.
Step 3
When joining the pipe, align the spigot of the pipe with the bell of the pipe previously laid.

Spigot Bell Spigot Bell

Step 4
Join the pipe. Up to 24" diameter, the pipe can usually be barred home. Place a block
of wood across the pipe invert to protect the bell. For larger pipe use a come-along to join
the pipe. The mantle section of the gasket rolls over the compression area of the gasket
and comes to rest in the annular space.

Note: -No Scale-


Compliance with the above procedures helps ensure good joints. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Joining Procedure for Grand Prairie


TX 3.14 01-25-10
Self Lubricating Gaskets Houston HEIDELBERGCEMENT Group
Reinforced Concrete Pipe

Step 1
Ensure that the bell and spigot of the pipe are clean, and free of debris.

Spigot Bell

Step 2
Place the gasket evenly around the spigot end of the pipe as shown above. Do not lubricate
the spigot. The bottom of the gasket should rest firmly against the spigot shoulder.

Step 3
Apply an even amount of lubricant to the bell and to the face of the gasket.

Step 4
When joining the pipe, align the spigot of the pipe with the bell of the pipe previously laid.

Spigot Bell Spigot Bell

Step 5
Join the pipe. Up to 24" diameter, the pipe can usually be barred home. Place a block
of wood across the pipe invert to protect the bell. For larger pipe use a come-along to join
the pipe.

Note: -No Scale-


Compliance with the above procedures helps ensure good joints. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Grand Prairie
Joining Procedure for Profile Gaskets TX 3.15 01-25-10
Houston
HEIDELBERGCEMENT Group
Precast Box Culverts
Lift Holes - 2 1/2" Diameter

Top
Slab

Span Wall

Rise
A

Bottom C
Slab

Typical Section

Standard Box Dimensions Standard Box Dimensions Standard Box Dimensions


Top Bottom Top Bottom Top Bottom
Span Rise Slab Slab Wall Weight Span Rise Slab Slab Wall Weight Span Rise Slab Slab Wall Weight
(Ft.) (Ft.) (In.) (In.) (In.) (Lbs./ft.) (Ft.) (Ft.) (In.) (In.) (In.) (Lbs./ft.) (Ft.) (Ft.) (In.) (In.) (In.) (Lbs./ft.)

3 2 7 6 4 848 8 3 8 8 8 2652 11 4 11 11 11 5010


3 3 7 6 4 952 8 4 8 8 8 2859 11 5 11 11 11 5294
8 5 8 8 8 3066 11 6 11 11 11 5578
4 2 7 1/2 6 5 1146 8 6 8 8 8 3272 11 7 11 11 11 5862
4 3 7 1/2 6 5 1276 8 7 8 8 8 3479 11 8 11 11 11 6146
4 4 7 1/2 6 5 1405 8 8 8 8 8 3686 11 9 11 11 11 6430
5 2 8 7 6 1541 11 10 11 11 11 6715
9 4 9 9 9 3511 11 11 11 11 11 6999
5 3 8 7 6 1696 9 5 9 9 9 3744
5 4 8 7 6 1851 9 6 9 9 9 3976 12 4 12 12 12 5856
5 5 8 7 6 2006 9 7 9 9 9 4209 12 5 12 12 12 6166
6 2 8 7 7 1821 9 8 9 9 9 4441 12 6 12 12 12 6476
6 3 8 7 7 2002 9 9 9 9 9 4674 12 7 12 12 12 6786
6 4 8 7 7 2183 12 8 12 12 12 7096
10 4 10 10 10 4228 12 9 12 12 12 7406
6 5 8 7 7 2364 10 5 10 10 10 4486
6 6 8 7 7 2545 12 10 12 12 12 7716
10 6 10 10 10 4745 12 11 12 12 12 8026
7 2 8 8 8 2238 10 7 10 10 10 5003 12 12 12 12 12 8336
7 3 8 8 8 2446 10 8 10 10 10 5261
7 4 8 8 8 2652 10 9 10 10 10 5520
7 5 8 8 8 2859 10 10 10 10 10 5778
7 6 8 8 8 3066
7 7 8 8 8 3272

Note: A = Wall thickness


C = 2" for 4", 5" and 6" wall -No Scale-
C = 4" for 7" and greater wall All dimensions subject to allowable
Contact manufacturer for standard joint lengths. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Reinforced Concrete Grand Prairie


TX 4 .1 01-25-10
Precast Box Section Houston
HEIDELBERGCEMENT Group
Precast Box Culverts

Span "B"

**
Bend
Angle

12" Min.
Typ.

Plan View

Span / Maximum Angle


Box "B" Max. "B" Max
Span Angle Angle
(Feet) (Feet) (Deg.) (Feet) (Deg.)

3 3 57 4 78
4 3 45 4 63
5 3 37 4 53
6 3 31 4 45
7 3 27 4 39
8 3 24 4 35
9 3 21 4 32
10 3 19 4 29
11 3 17
12 3 16

Note:
-No Scale-
** Shipments over 8 feet wide require a permit which will restrict delivery
hours. Check with your Hanson representative for information.
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Reinforced Concrete Grand Prairie


TX 4.2 01-25-10
Precast Box Bends Houston HEIDELBERGCEMENT Group
Precast Box Culverts

or Diameter
Span "A"

Span "B"
Plan View
Rise "A"

or Diameter
Rise "B"
Flow Flow
Line Line
Elevation - Bottoms Even

or Diameter
Rise "A"

Rise "B"

Flow
Flow
Line
Line
Elevation - Centerline Even
or Diameter
Rise "B"
Rise "A"

Flow
Flow Line
Line
-No Scale-
Elevation - Tops Even All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Reinforced Concrete Grand Prairie


4.3
Houston
TX 01-25-10
Precast Box Transition - Option 1 HEIDELBERGCEMENT Group
Precast Box Culverts

6", 8" or 12"


as Required

Upstream Box Size


or Diameter

Downstream
Box Spigot Upstream
Box Bell

Reducing Stopper

Note: -No Scale-


Reduction may be centered or All dimensions subject to allowable
offset as required. specification tolerances.

TITLE PLANT STATE SECTION PAGE . DATE

Reinforced Concrete Grand Prairie


TX 4.4 01-25-10
Precast Box Transition - Option 2 Houston HEIDELBERGCEMENT Group
Precast Box Culverts

Wall
Dimensions
Span / Rise
Manufacturer Estimated Quantities
Span Rise Wall Pre-Formed Mastic Span Rise Wall Pre-Formed Mastic
(Ft.) (Ft.) (In.) Size Pcs. / Jt. Gal./Jt. (Ft.) (Ft.) (In.) Size Pcs. / Jt. Gal./Jt.

3 2 4 1 1/2" x 3'-6" 3.1 1.66 9 4 9 1 1/2" x 3'-6" 8.2 6.87


3 3 4 1 1/2" x 3'-6" 3.6 1.94 9 5 9 1 1/2" x 3'-6" 8.7 7.32
9 6 9 1 1/2" x 3'-6" 9.3 7.77
4 2 5 1 1/2" x 3'-6" 3.8 2.26 9 7 9 1 1/2" x 3'-6" 9.9 8.22
4 3 5 1 1/2" x 3'-6" 4.4 2.57 9 8 9 1 1/2" x 3'-6" 10.5 8.67
4 4 5 1 1/2" x 3'-6" 4.9 2.88 9 9 9 1 1/2" x 3'-6" 11.0 9.12

5 2 6 1 1/2" x 3'-6" 4.5 2.94 10 4 10 1 1/2" x 3'-6" 8.8 8.00


5 3 6 1 1/2" x 3'-6" 5.0 3.29 10 5 10 1 1/2" x 3'-6" 9.4 8.48
5 4 6 1 1/2" x 3'-6" 5.6 3.64 10 6 10 1 1/2" x 3'-6" 10.0 8.97
5 5 6 1 1/2" x 3'-6" 6.2 3.98 10 7 10 1 1/2" x 3'-6" 10.6 9.45
10 8 10 1 1/2" x 3'-6" 11.1 9.94
6 2 7 1 1/2" x 3'-6" 5.1 3.71 10 9 10 1 1/2" x 3'-6" 11.7 10.42
6 3 7 1 1/2" x 3'-6" 5.7 4.10 10 10 10 1 1/2" x 3'-6" 12.3 10.91
6 4 7 1 1/2" x 3'-6" 6.3 4.48
6 5 7 1 1/2" x 3'-6" 6.8 4.86 11 4 11 1 1/2" x 3'-6" 9.5 9.22
6 6 7 1 1/2" x 3'-6" 7.4 5.24 11 5 11 1 1/2" x 3'-6" 10.1 9.74
11 6 11 1 1/2" x 3'-6" 10.6 10.26
7 2 8 1 1/2" x 3'-6" 5.8 4.57 11 7 11 1 1/2" x 3'-6" 11.2 10.78
7 3 8 1 1/2" x 3'-6" 6.4 4.99 11 8 11 1 1/2" x 3'-6" 11.8 11.30
7 4 8 1 1/2" x 3'-6" 6.9 5.40 11 9 11 1 1/2" x 3'-6" 12.4 11.82
7 5 8 1 1/2" x 3'-6" 7.5 5.82 11 10 11 1 1/2" x 3'-6" 12.9 12.34
7 6 8 1 1/2" x 3'-6" 8.1 6.23 11 11 11 1 1/2" x 3'-6" 13.5 12.86
7 7 8 1 1/2" x 3'-6" 8.6 6.65
12 4 12 1 1/2" x 3'-6" 10.2 10.53
8 3 8 1/
1 2" x 3'-6" 6.9 5.40 12 5 12 1 1/2" x 3'-6" 10.7 11.08
8 4 8 1 1/2" x 3'-6" 7.5 5.82 12 6 12 1 1/2" x 3'-6" 11.3 11.64
8 5 8 1 1/2" x 3'-6" 8.1 6.23 12 7 12 1 1/2" x 3'-6" 11.9 12.19
8 6 8 1 1/2" x 3'-6" 8.6 6.65 12 8 12 1 1/2" x 3'-6" 12.5 12.74
8 7 8 1 1/2" x 3'-6" 9.2 7.06 12 9 12 1 1/2" x 3'-6" 13.0 13.30
8 8 8 1 1/2" x 3'-6" 9.8 7.48 12 10 12 1 1/2" x 3'-6" 13.6 13.85
12 11 12 1 1/2" x 3'-6" 14.2 14.41
12 12 12 1 1/2" x 3'-6" 14.7 14.96

-No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE SECTION PAGE . DATE

Grand Prairie
Precast Box Joint Material TX 4.5 01-25-10
Houston
HEIDELBERGCEMENT Group
Precast Box Culverts
1. Grade trench bottom and bring bedding material to height. Bedding material should be 6" thick
minimum, or more depending on existing soils. See project plans and specifications for details.
2. Preformed flexible plastic joint material (Ram-Nek or equal) is installed on the box spigot (top
half of box) at the shoulder of the joint. The joint material is installed in the bell (bottom half of box)
at the shoulder. Joint priming is not required but is recommended according to the manufacturer.

Protective paper wrapper is left in place


until lowering and installation.

Groove Groove

Tongue Tongue

In cold weather, the joint material should be kept warm prior to installation to keep the mastic pliable
and compressible.

3. A pipe puller or come-a-long should be used to pull joints home. This is preferable to
pushing since it minimizes damage to the box culvert.

4. A small gap can be expected at each joint. For boxes with spans of 10 feet or less, a normal space
can be 3/8" to 1" depending on the size of the box. TXDOT enforces their spec.; section 462.4(5),
last paragraph, as an installation standard for both straight and pulled joints. This is a 1" maximum
gap.

5. Each box joint should be checked for grade and alignment. We recommend that the grade be
checked at the lower haunch and not on the centerline.

-No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Grand Prairie
Box Culvert Installation Houston
TX 4 .6 01-25-10
HEIDELBERGCEMENT Group
Precast Manholes
Frame & Cover
(By Others as Req'd.)

Adjustment Ring(s)

Conc. Cone Ecc. Cone


Concentric Eccentric
Flat Slab Top Flat Slab Top

Riser(s)

48"
Transition Cone Base Section
Transition Slab

Large Diameter MH Tee


Base Section

Note:
Manhole steps are available as required.

Inverts and resilient connectors furnished as required.

Conforms to current ASTM C-478 specification for

reinforced concrete manhole sections. -No Scale-


Maximum burial depth for manholes = 30 feet.
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Precast Manhole Assembly Diagram All Plants TX 5 .1 01-25-10


HEIDELBERGCEMENT Group
Precast Manholes

Confined Groove Joint Single Offset Joint


Profile or Self-Lubricated Gasket

Note:
Contact plant for availability of joint styles.

Conforms to current ASTM C-478 specification for -No Scale-


reinforced concrete manhole sections. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Grand Prairie
Precast Manhole Joints Houston TX 5.2 01-25-10
Waco HEIDELBERGCEMENT Group
(Precast) Manholes

Single Offset Joint

Downstream

Confined Groove Joint


Plan View
Bend x Tee Manhole (Lay Right)

12" Typ.
Single Offset Joint Confined Groove Joint

Single Offset Joint


Single Offset Joint

Branch L.L.

Downstream
Downstream

Spigot L.L.

Confined Groove Joint


Bell L.L.
Confined Groove Joint

Laying Length
Plan View
Tee Manhole Side View
Tee Manhole
Single Offset Joint

Downstream


Confined Groove Joint

Plan View
Bend x Tee Manhole (Lay Left)
Note:
Manhole Steps are available as required.
-No Scale-
Usual riser diameter is 48" but riser diameter All dimensions subject to allowable
equal to line pipe diameter is possible. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Tee-Type Manhole Assembly Grand Prairie


Houston TX 5 .3 01-25-10
48"- 66" Line Size Waco HEIDELBERGCEMENT Group
(Precast) Manholes

Single Offset Joint

Downstream

Confined Groove Joint


Plan View Single Offset Joint Confined Groove Joint

Bend x Tee Manhole (Lay Right)


12" Typ.

Single Offset Joint


Single Offset Joint

Branch L.L.
Downstream

Downstream
Bell L.L. Spigot L.L.

Confined Groove Joint


Confined Groove Joint

Laying Length
Plan View
Tee Manhole Side View
Tee Manhole
Single Offset Joint

Downstream
Confined Groove Joint

Plan View
Bend x Tee Manhole (Lay Left)

Note:
Manhole Steps are available as required.
-No Scale-
Usual riser diameter is 48" but riser diameter All dimensions subject to allowable
equal to line pipe diameter is possible. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Tee-Type Manhole Assembly Grand Prairie


Houston TX 5 .4 01-25-10
72" Line Size & Larger Waco HEIDELBERGCEMENT Group
Precast Manholes

8" Varies 8"


3 1/2"

Illustrated:
Concentric Cone
Available:
Eccentric Cone

Rubber Gaskets
at all Joints

Varies
Typical Lifting
Inserts in all
Riser and Cone
Sections

Varies
Invert Channel - Shall be
Varies "U"-Shaped: Sloped Min. Water-Tight
of 1" per 12". Gaskets @ all
Pipe Connections

5" 4' - 0" 5"

Flattop Illustration Varies


for Shallow Manhole Varies
*
5" 4' - 0" 5"
4' - 10"

Section View
4' I.D. Manhole - Regular Base
with Reducing Cone
Materials & Features
HOLES AS SPECIFIED: Max diameter = 32"
CONCRETE: 5,000 PSI, 28 day strength.
REINFORCING: Meets or exceeds ASTM C478 requirements.
Average weight of 24" depth base w/8" invert = 4,500 lbs.
Estimated weiight of riser and cone sections = 870 lbs. / vt. ft.

* - Extended base is available to meet local requirements.


In the event a boot is loose contact your Hanson representative
to resolve.
-No Scale-
All dimensions subject to allowable
"Manufactured to your specifications." specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

4' I.D. Manhole All Plants 5 .5


TX 01-25-10
Regular Base w / Reducing Cone HEIDELBERGCEMENT Group
Precast Manholes
8" Varies 8"

Illustrated:
Concentric Cone
Available:
Eccentric Cone

Rubber Gaskets
Varies at all 4' Joints

13" & 16"

4' - 0"
Rubber Gaskets
6"
at all 5' Joints
(TYP.)

Invert Channel - Shall be


Water-Tight
"U"-Shaped: Sloped Min.
"B" Gaskets @ all
of 1" per 12".
Pipe Connections
Flattop Illustration
for Shallow Manhole
8" or 12" 6" (Typ.)

*
"C" "A" "C"
"B"
Materials & Features
HOLES AS SPECIFIED: for 5' I.D. max diameter = 40" Section View
for 6' I.D. max diameter = 54" 5' / 4' & 6' / 4' I.D. Manhole
CONCRETE: 5,000 PSI, 28 day strength. Extended Base with Reducing Cone
REINFORCING: Meets or exceeds ASTM C478 requirements.
Average weight of 24" depth base w/8" invert:
for 5' I.D. = 7,500 lbs. Pipe I.D. O.D. Wall
for 6' I.D. = 10,600 lbs. Size Thk.
Estimated weight of riser and sections: "A" "B" "C"
for 5' I.D. = 1,325 lbs. / vt. ft.
for 6' I.D. = 1,800 lbs. / vt. ft. 5' 5' - 0" 6' - 0" 6"
For pipe sizes 15" and larger, invert shall be equal to 6' 6' - 0" 7' - 2" 7"
the larger pipe diameter.
- Extended base shown: Regular base also available."
*
In the event a boot is loose contact your Hanson representative
to resolve. -No Scale-
All dimensions subject to allowable
"Manufactured to your specifications." specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

5' / 4' & 6' / 4'I.D. Manhole 5.6


All Plants TX 01-25-10
Extended Base w / Reducing Cone HEIDELBERGCEMENT Group
Precast Manholes
For Pipe Entering the Manhole at Excessive
Depths Above the Flow Line Out, the Contractor
May be Responsible for Grout Work Necessary to
Bring Channel up to Flow Line on Inlet Pipe.

Contractor Responsible
For Additional Filler
Around Pipe After
Installation.

Grouted Invert w/ Offset to Match


Flowline of Pipe. Slight Field
Adjustments May Be Necessary.

Rubber Gasket

Invert Channel - Shall be


"U"-Shaped: Sloped Min.
of 1" per 12".
Varies
"A" "C" "A" "C"
See
Pipe Max.

Varies
in notes

Varies
*
"B"
"B"

Plan View Section View

Pipe I.D. O.D. Wall


Materials & Features Size Thk.
"A" "B" "C"
HOLES AS SPECIFIED:
4' 4' - 0" 4' - 10" 5"
For 4' I.D. max. diameter = 32"
5' 5' - 0" 6' - 0" 6"
For 5' I.D. max. diameter = 40"
6' 6' - 0" 7' - 2" 7"
For 6' I.D. max. diameter = 54"
CONCRETE: 5,000 PSI, 28 day strength.
REINFORCING: Meets or exceeds ASTM C478 requirements.
Average weight of 24" depth base w/8" invert = 4,500 lbs.
Water-tight gaskets at all pipe connections.
* - Regular base shown: Extended base also available.
In the event a boot is loose contact your Hanson representative
-No Scale-
All dimensions subject to allowable
to resolve. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Details: 4', 5' & 6' I.D. Precast


All Plants TX 5.7 01-25-10
Regular Manhole Base HEIDELBERGCEMENT Group
Precast Manholes

A A

Plan View

6' - 0"

5' - 0"

4' - 0" Rubber Gaskets at


all 4' Joints

16"

Section View

Materials & Features


CONCRETE: 5,000 PSI, 28 day strength.
REINFORCING: Meets or exceeds ASTM C478 requirements.
CONSTRUCTION OF PRECAST is in accordance with ASTM C478. -No Scale-
Concrete is poured according to ACI-500. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

5' x 4' Conical Adaptor Waco TX 5.8 01-25-10


HEIDELBERGCEMENT Group
Precast Manholes

8" 24" 8" 8" 24" 8"

4" 3"

Lifting Lifting
Varies Inserts Varies Inserts

5" 5"

Concentric Cone Eccentric Cone


24" Opening 24" Opening

8" 34 1/2" 8" 8" 34 1/2" 8"

3" 3"

Lifting Lifting
Varies Inserts Varies Inserts

5" 5"

Concentric Cone Eccentric Cone


34 1/2" Opening 34 1/2" Opening

Materials & Features


CONCRETE: 5,000 PSI, 28 day strength.
REINFORCING: Meets or exceeds ASTM C478 requirements. -No Scale-
30" also available in North Texas. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Waco
Hanson 48" Manhole Reducing Cone Detail Houston TX 5.9 01-25-10
HEIDELBERGCEMENT Group
Precast Manholes
Std. City Ring and
Cover (24" or 32" Dia.)
Installed by Contractor.

Concentric
Cone Grade Ring(s) for
Adjustment to
Final Grade.
25 or 40 Vert. Ft.

Varies

Joint & Gasket


Detailed on Page 5.6
12" Min.

60" thru 120" Pipe Connectors


RCP Usual
5 to 8 Vert. Ft.

Are Kor-N-Seal I
or II by NPC or
A Approved Equal

A
w/ Precast Base

Base Slab Reinforcing

30' Deep Structure


60" - 6" Thick Slab min. - #5 @ 8" ea.way
72" - 8" Thick Slab min. - #5 @ 8" ea.way
84" - 8" Thick Slab min. - #5 @ 6" ea.way
96" - 10" Thick Slab min. - #5 @ 6" ea.way

45' Deep Structure


60" - 8" Thick Slab min. - #5 @ 8" ea.way Isometric View
72" - 8" Thick Slab min. - #5 @ 8" ea.way
Section A-A 84" - 10" Thick Slab min. - #5 @ 6" ea.way
96" - 12" Thick Slab min. - #5 @ 6" ea.way
All Reinforcing has 1 1/2" cover from top of slab.

Materials & Features Note:


Inverts shall be specifically sized for
CONCRETE: 5,000 PSI in 28 days.
connecting pipes; and shall be U-Shaped
REINFORCING STEEL: per ASTM A-615, Grade 60. with the min. depth 3/4 of the largest
REINFORCING to meet AASHTO HS 20-44 Loading. pipe diameter.
DESIGN EQUAL TO OR EXCEEDS ASTM C-478
In the event a boot is loose contact your Hanson representative -No Scale-
to resolve. All dimensions subject to allowable
specification tolerances.
TITLE PLANT STATE .
SECTION PAGE DATE

30 & 45 Ft. Depth Houston 5.10


San Antonio
TX 01-25-10
60" thru 96"Large Base Manhole HEIDELBERGCEMENT Group
Precast Manholes

Std. City Ring and


Cover (24" or 32" Dia.)
Installed by Contractor.
Concentric

Grade Ring(s) for


Cone

Adjustment to
Final Grade.

Joint & Gasket


Detailed on Page 5.6
Varies

Transition Slab

3/ "
4
Varies
Bottom Box

Knock Outs
As Required
Varies

Varies

Side View

Isometric View

Materials & Features


CONCRETE: 5,000 PSI in 28 days.
REINFORCING STEEL: per ASTM A-615 / A-185
REINFORCING to meet AASHTO HS 20-44 Loading.
BASE DESIGN EQUAL TO OR EXCEEDS ASTM C-357
RISER DESIGN EQUAL TO OR EXCEEDS ASTM C-478
In the event a boot is loose contact your Hanson representative
to resolve. -No Scale-
All dimensions subject to allowable
specification tolerances.
TITLE PLANT STATE .
SECTION PAGE DATE

Houston
Type "C" Manhole San Antonio
TX 5.11 01-25-10
HEIDELBERGCEMENT Group
Precast Manholes

48" Fiberglass Riser

2.746"

1"
8" 42" 8"

1"

4 1/4"
Transition Slab
for Fiberglass Riser
8"

0.332"
8"

2 Slope
36" Std. Hgt.

Spec.
Per

Profile Joint Detail

Materials & Features


CONCRETE: 5,000 PSI in 28 days.
REINFORCING STEEL: per ASTM A-615, Grade 60.
REINFORCING to meet AASHTO HS 20-44 Loading.
-No Scale-
DESIGN EQUAL TO OR EXCEEDS ASTM C-478 All dimensions subject to allowable
specification tolerances.
TITLE PLANT STATE .
SECTION PAGE DATE

ASTM C-478 Special Base Houston TX 5.12 01-25-10


HEIDELBERGCEMENT Group
Precast Manholes

Hatch Cast in as Specified

A
Varies

B
D

Section View
(Base configuration for 60", 72" & 84") Isometric View

Product Dimensions
A B C D

60"
72"

84" Contact your local Hanson


96" representative for product
108"
dimensions. Section View
Base configuration for 96"
120"

132"
144"

Materials & Features


CONCRETE: 5,000 PSI in 28 days.
REINFORCING STEEL: per ASTM A-615 / A-185
REINFORCING to meet AASHTO HS 20-44 Loading.
Section View
BASE DESIGN EQUAL TO OR EXCEEDS ASTM C-357 Base configuration for 108"-144"
RISER DESIGN EQUAL TO OR EXCEEDS ASTM C-478
(A). Hatches as specified by Engineer. -No Scale-
All dimensions subject to allowable
In the event a boot is loose contact your Hanson representative
specification tolerances.
to resolve.
TITLE PLANT STATE .
SECTION PAGE DATE

Typical Wetwells - Various Diameters All Plants TX 5.13 01-25-10


HEIDELBERGCEMENT Group
Precast Manholes

Access Covers as Specified


Concentric Cover Illustrated
Eccentric Cover Available

18"

Typical Lifting Anchors


in all Riser Sections

Risers as Specified

Risers as Specified

6"

18"

11" 10' - 0" 11" Bottom Slab


12' - 10" x 12' - 10" Square
11' - 10" (Chamfer Corners 18")

Section View
10' I.D. Wet Well - w/Extended Slab

Materials & Features


CONCRETE: 5,000 PSI, 28 day strength.
REINFORCING: Meets or exceeds ASTM C478 requirements.
-No Scale-
"Manufactured to your specifications." All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

10' I.D. Wet Well TX 5.14 01-25-10


Waco 09-28-09
w / Extended Bottom Slab HEIDELBERGCEMENT Group
Precast Manholes

Access Covers as Specified


Concentric Cover Illustrated
Eccentric Cover Available

18"

Typical Lifting Anchors


in all Riser Sections

Risers as Specified

Risers as Specified

6"

18"

13" 12' - 0" 13" Bottom Slab


15' - 2" x 15' - 2" Square
14' - 2" (Chamfer Corners 18")

Section View
12' I.D. Wet Well - w/Extended Slab

Materials & Features


CONCRETE: 5,000 PSI, 28 day strength.
REINFORCING: Meets or exceeds ASTM C478 requirements.
-No Scale-
"Manufactured to your specifications." All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

12' I.D. Wet Well TX 5.15 01-25-10


Waco 09-28-09
w / Extended Bottom Slab HEIDELBERGCEMENT Group
1 "O"-Ring Gasket 2 Lubricate bell 3
joint surface
Carefully clean all dirt & foreign liberally,
objects from the joining surface of covering
the bell or groove end of pipe. entire inside
surface using
proper pipe
Carefully clean spigot or tongue gasket
end of pipe, including the gasket lubricant. Lubricate the gasket
recess. Inspect the bell and spigot throughly before it is
ends of each section to make sure placed on the spigot
they are free from cracks, chips or or tongue.
voids that will interfere with gasket. Bell and Gasket not lubricated or improperly lubricated may
Improperly prepared bell and spigot surfaces may prevent cause the gasket to roll and leak or possibly damage the bell.
homing of the pipe or keep the gasket from sealing.
5 Align the bell & spigot to be
joined. Before homing the
4 joint, check that the gasket is
**IMPORTANT** in contact with the bell end
Fit the gasket carefully,
equalizing the rubber gasket entrance taper around the
stretch by running a smooth, entire circumference.
round object (inserted
between the gasket & spigot) Do not force sections
around the entire together. If sections do not
circumference several times. seat properly, unstack and
contact your Hanson Sales
Representative.

Unequal stretch could cause bunching of the gasket Improper alignment can dislodge gasket, causing leaks or
and may cause leaks in the joint or crack the bell. possibly breaking the bell.

Profile Gasket
5. lead-in taper surface on the outer edge of the
1. Manhole sections should be handed with bell. Align spigot with the bell. Gasket should
extreme caution to avoid chipping of the bell touch lead-in taper around the entire
or spigot ends. Proper lifting devices must be circumference before pushing the pipe home.
used on all sections.
6. Push the manhole section carefully, until the
2. Inspect gasket sealing area for any voids or spigot is all the way home. (Fig B) Do not
rough edges that may interfere with the seal.
force sections together. If sections do not
3. Place the 4-G Gasket in the step of the spigot. seat properly, unstack and contact your
(Making sure that the pointed end of the Hanson Sales Representative.
gasket is toward the end of the pipe as shown
7. Every manhole will not come home exactly
in Fig A.)
the same. Differences in application,
4. **IMPORTANT** Equalize the stretch on consistency of lubricants, dimensions in the
the gasket by pulling the sealing lube away spigot and groove will cause variations in
from the spigot at least one inch and then installation. If joining problems arise, please Fig. A
releasing the gasket. Repeat this every three contact the manhole manufacturer
or four inches around the circumference of immediately rather than forcing manhole
the pipe. Equalization of stretch makes sure sections together with subsequent damage to
that the gasket has the same stretched cross- the manhole.
section and tension throughout. **Do not
lube the gasket or spigot end of the pipe.** 8. All testing should be performed prior to
backfill of the manhole. Problems can not be
5. Remove all dirt and other foreign matter from detected after the manhole is backfilled.
the inside surface of the bell. Apply lube to Testing the manhole after backfill voids all
the inner surface of the bell including the warranties.

Note: Manholes in excess of 30' in depth must be vacuum tested prior to backfill. The loads Fig. B
presented by soils and possible groundwater at 30' in addition to the load from the vacuum may
exceed the design capacity of the pipe to manhole connector.
TITLE PLANT STATE .
SECTION PAGE DATE

O-Ring & Profile Gasket All Plants TX 5.16 01-25-10


Installation on Manholes HEIDELBERGCEMENT Group
Precast Manholes

Step One Step Two Step Three


Torque Torque Torque Re-torque All
Clamp Bolt All Outer All Inner Clamp Bolts
to 60 lb/in Clamp Bolts Clamp Bolts to 60 lb/in
to 60 lb/in to 60 lb/in

Single Clamp Multiple Clamps

Instructions
1. Clean pipe and boot to ensure no dirt or foreign materials are present.

2. Clamping surface on pipe must be clean and smooth.

3. Center pipe in opening and insert until pipe is at least equal to the
inside plane of the manhole.

4. Attach take-up clamps(s) and stagger screw(s) of clamps(s) around


the groove of the gasket so that take-up pressure will be equalized.
Make sure each clamp is completely in the correct groove.

5. Using a torque ratchet or torque wrench, gradually tighten all screw(s)


of clamp(s) in an alternating pattern to 60 lbs/in torque.

6. After reaching 60 lbs/in torque on final screw, check all screws again
to ensure equal compression of all clamps.

7. If system is to be tested, testing shall be completed prior to backfilling,


following all recommendations and requirements of the test system
manufacturer. Vacuum testing shall be conducted in accordance with
ASTM C-1244.

8. Adjust pipe to line and grade. Use proper bedding, backfill materials
and techniques so that pipe deflection and deformation is minimized.

9. Any pipe stubs installed in the manhole must be positively restrained


from movement.

10. Vacuum testing after backfill voids warranty.

For more information contact yor local Hanson Representative.

TITLE PLANT STATE .


SECTION PAGE DATE

Pipe to Manhole Connector All Plants 5.17


TX 01-25-10
Installation Guide HEIDELBERGCEMENT Group
Precast Bridge Units

Precast Bridge Unit

Span - varies

Rise - varies
Cast-in-place footing
Optional cast-in-place floor

anson's precast bridge units bottoms are desired, wetlands Connections are provided for
H are rectangular three-sided
reinforced concrete structures
must be spanned, the span is
longer than can be accommo-
attaching guard rails parapets
and end and wing walls.
designed to be installed on cast- dated with a precast box culvert
in-place concrete footings. and when cost and time of con- Individual sections are typically
struction are critical. eight feet long and are butted
Precast bridge units are pro- against adjacent units. The
duced with spans from 16 to 40 Hanson's engineers design the joints are sealed with an exter-
feet for prestressed units and cast-in-place footings based on nal wrapper.
16 to 20 feet for non-pre- soil bearing data provided by the
stressed. Rises are available owner. The precast sections are Hanson's precast bridge units
up to 12 feet. designed for each specific appli- have been used successfully
cation according to AASHTO2 for over a decade by state DOT's
Installations can be single or Standard Specifications for High- municipalities and private de-
multiple cells. way Bridges. velopers.

The units can be skewed up to Typical applications include new


43o to accommodate streambed or replacement highway bridges,
alignment. storm drains, stormwater man-
agement structures, culverts, cul-
Precast bridge units are recom- vert extensions and utility or pe-
mended where natural stream destrian tunnels.

TITLE PLANT STATE .


SECTION PAGE DATE

Grand Prairie
Typical Precast Bridge Unit Houston TX 6.1 01-25-10
HEIDELBERGCEMENT Group
Precast Bridge Units
Date:____________
Project Number:______________________________By:_____________
Project Name:_______________________________________________
Location & Description:________________________________________
Bid Schedule:________________________________________________
Engineer:___________________________________________________

Crown-Span Data

Rise
Span
Span

End View Plan View

* Span (ft) = __________


* Rise (ft) = __________
Wall (in) = __________
Top Slab (in) = __________
Haunch (in) = __________
* Soil Weight (pcf) = __________ Hydraulics:
* Grade Elev. (ft) = ____________
(Required only if structure
* Flowline (ft) = ____________
not already sized.)
* Length (ft) = __________
* Q (cfs) = __________
* Live Load = __________
Slope (%) = __________
* No. of Lanes = __________
* Soil Bearing Capacity (psi) = __________ * "n" Coeff. = __________

* Flared or Parallel Wingwalls __________ * Vel. (fps) = __________

Note: * = User Supplied Data.


TITLE PLANT STATE .
SECTION PAGE DATE

Grand Prairie
Crown-Span Design Data Sheet Houston TX 6 .2 01-25-10
HEIDELBERGCEMENT Group
Precast Bridge Units
Date:_____________
Project Number:______________________________By:_____________
Project Name:_______________________________________________
Location & Description:________________________________________
Bid Schedule:________________________________________________
Engineer:___________________________________________________

Crown-Span Data

Normal
Normal Rise Span

e
Span

Angl
Skew
Dsgn. Span

End View Plan View

* Span (ft) = __________ Dsgn. Span (ft) = __________


* Rise (ft) = __________ * Skew Angle (deg) = __________
Wall (in) = __________ (43 Max. Available)
Top Slab (in) = __________
Haunch (in) = __________
* Soil Weight (pcf) = __________ Hydraulics:
* Grade Elev. (ft) = ____________
(Required only if structure
* Flowline (ft) = ____________
not already sized.)
* Length (ft) = __________
* Q (cfs) = __________
* Live Load = __________
* No. of Lanes = __________ Slope (%) = __________

* Soil Bearing Capacity (psi) = __________ * "n" Coeff. = __________


* Flared or Parallel Wingwalls __________ * Vel. (fps) = __________

Note: * = User Supplied Data.


TITLE PLANT STATE .
SECTION PAGE DATE

Grand Prairie
Crown-Span Design Data Sheet Houston TX 6 .3 01-25-10
HEIDELBERGCEMENT Group
Precast Modular Bridge Units

anson's precast modular Standard Specifications for


H bridge system consists
of precast pier or pile caps,
Highway Bridges. They are
currently accepted by Ala-
The advantages of this
system include a smaller
construction crew on site, no
deck panels and parapet rails. bama, Arkansas, Louisiana paving required over deck
and Mississippi State DOT's. units and 100% precast
Precast bridge systems are superstructure reduces
available in 15', 19', 25', 31', Components are non-pre- construction time. End on
34', and 40' span lenghts and stressed and designed for an construction allows for
incremental widths of 3' - 6". AASHTO HS-20 loading. This assembly in narrow right-of-
This allows for unlimited allows the designer to "build"a ways.
lengths, widths, skews and bridge structure by selecting
styles of bridge systems when and assembling components
combined with a series of from a menu of available parts.
substructures.
Typical applications include
Widths can be any multiple of utility line supports, vehicular
the basic 3' - 6 " beam width. bridges, predestrian bridges,
temporary bridges for mainte-
Modular components are de- nance of traffic and boat and
signed according to AASHTO parking docks.

TITLE PLANT STATE .


SECTION PAGE DATE

Typical Modular Precast Bridge Unit Houston TX 6.4 01-25-10


HEIDELBERGCEMENT Group
Precast Modular Bridge Units

Parapet Rail (Typ.)

Curb Unit Interior Unit(s) Curb Unit

Cross Section of Roadway

3'-6"
1'-3" 1'-3"
6" 5"
6" 2" 6" 2"
11"
7"
1'-7" 1'-7"
8" 2'-2" 8"

Section - Curb Unit


4'-2" 10" 10"
4'-2"
3'-6"
1'-9" 1'-9"
11" 17" Typ. 5"
11"
21" @ 34'
1' 24" @ 40' 7"

8" 2'-2" 8"


Section A-A Section B-B
Section - Interior Unit

Span
A B

1'-7"

10" 4'-2"

1'-9"
11"

A B
9" 9"
2'-0" 2'-0" 2'-0"

Elevation - Precast Parapet Rail


Spaces & Size Vary with Span

TITLE PLANT STATE .


SECTION PAGE DATE

Precast Modular Bridge Span Houston TX 6 .5 01-25-10


w/ Parapet Rail HEIDELBERGCEMENT Group
Precast Modular Bridge Units

Post and Rail (Typ.)


Narrow Back Curb Unit (Typ.)

Interior Unit(s)

Cross Section of Roadway

5"
1"
3'-6" 3'-2"

17" Typ. 5" 2'-2" 17" Typ.


21" @ 34' 21" @ 34'
9"
24" @ 40' 4" 7" 24" @ 40'
7"
8" 2'-5" 8"
8" 8" 3'-9"
2'-2"

Section - Interior Unit Section - Curb Unit

Post and Rail (Typ.)

Alt. Curb 10" x 10" Post

8"
3/ " Hole
4
4'-0"

Assembly of Units 1 1/2" Hole


10 3/4"

1" Hole
1'-0"
1" 4"
10"
11 1/4"

9"

Precast Post
2'-2"

1 1/2" Hole
10 3/4"

2 1/2" x 6" Drain


4"

1" Hole

Alt. Curb
-No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Precast Modular Bridge Span Houston TX 6 .6 01-25-10


w/Post and Rail HEIDELBERGCEMENT Group
Precast Modular Bridge Units
9" 9"
6" Width in Multiples of 3'-6" 6"

Slabs @ 3' - 6"


Clear Width Roadway (Parapet)
Walkway
9" 9"
6" Width in Multiples of 3'-6" 6"

Slabs @ 3' - 6"

Roadway w/Walkway (Rail)


Walkway
9" 9"
6" Width in Multiples of 3'-6" 6"

Slabs @ 3' - 6"

Roadway w/Walkway (Parapet)

Width in Multiples of 3'-6"


6" Clear Roadway 6"

Slabs @ 3' - 6"

Clear Width Roadway (Post & Rail)

-No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Precast Modular Bridge Span


TX 6.7 01-25-10
Typical Sections HEIDELBERGCEMENT Group
Bridge Products

FULL FLOW CONSTANTS


for
Hanson Arch and Crown Span

Use of Tables
Substituting Different Products at Full Flow Conditions

Selection of pipe sizes for flows as determined by Manning's equation:

V = 1.486/n
R.66 S.5

Where; Q = A V

Substitute for V:
Q = A (1.486/n R.66 S.5)

Therefore: Q = K S.5

Example: Substitute a Box (or Boxes) for 2 - 30 inch Arch Pipes

K for 1 - 30 inch Arch Pipe = 368 (from table)


K for 2 - 30 inch Arch Pipes = 736
K for equivalent Box Culvert; 4' x 2' Box = 743 (from table)
Therefore a single 4' x 2' Box Culvert (RCB) will substitute.

HA - Hanson Arch - use n = 0.012


CS - Crown Span - use n = 0.012

A = Cross sectional area R = Hydraulic radius = area/inside permeter


V = Velocity (fps) S = Slope of line (feet/foot)
Q = Flow (cuft/sec) 1 cu ft = 7.48 gallons

TITLE PLANT STATE .


SECTION PAGE DATE

Bridge Products - Full Flow Constants All Plants TX 6.9 01-25-10


HEIDELBERGCEMENT Group
Bridge Products
Size / Type Equivalent Area Hydraulic K
Size Radius

12 x 4 HA 41.9 1.45 6623


12 x 4 CS 47 1.52 7688
14 x 4 HA 49.88 1.51 8123
13 x 4 CS 51 1.55 8447
16 x 4 HA 55.1 1.51 8971
14 x 4 CS 55 1.58 9208
12 x 5 HA 53.9 1.74 9626
15 x 4 CS 59 1.60 9972
16 x 4 CS 63 1.62 10738
12 x 5 CS 59 1.80 10758
17 x 4 CS 67 1.64 11505
14 x 5 HA 63.88 1.83 11780
13 x 5 CS 64 1.84 11842
18 x 4 CS 71 1.66 12274
12 x 6 HA 65.9 2.00 12894
14 x 5 CS 69 1.87 12931
19 x 4 CS 75 1.67 13044
16 x 5 HA 71.1 1.85 13222
20 x 4 CS 79 1.69 13815
15 x 5 CS 74 1.91 14026
12 x 6 CS 71 2.04 14069
21 x 4 CS 83 1.70 14588
16 x 5 CS 79 1.93 15124
22 x 4 CS 87 1.71 15361
13 x 6 CS 77 2.09 15514
14 x 6 HA 77.88 2.11 15778
20 X 5 HA 84.8 1.87 15861
23 x 4 CS 91 1.72 16134
17 x 5 CS 84 1.96 16226
12 x 7 HA 77.9 2.23 16372
24 x 4 CS 95 1.73 16909
14 x 6 CS 83 2.14 16969
18 x 5 CS 89 1.99 17330
24 x 5 HA 94.9 1.84 17547
12 x 7 CS 83 2.25 17572
25 x 4 CS 99 1.74 17684
16 x 6 HA 87.1 2.16 17908
15 x 6 CS 89 2.18 18433
19 x 5 CS 94 2.01 18437
26 x 4 CS 103 1.75 18459
27 x 4 CS 107 1.76 19236
13 x 7 CS 90 2.32 19411
20 x 5 CS 99 2.03 19546
16 x 6 CS 95 2.22 19903
28 x 4 CS 111 1.77 20012

Note: Not all sizes shown may be structurally available.


Designs are dependent on fill height.
TITLE PLANT STATE .
SECTION PAGE DATE

Bridge Products - Full Flow Constants All Plants TX 6.10 01-25-10


HEIDELBERGCEMENT Group
Bridge Products
Size / Type Equivalent Area Hydraulic K
Size Radius

12 x 8 HA 89.9 2.43 20019


14 x 7 HA 91.88 2.36 20050
21 x 5 CS 104 2.05 20658
29 x 4 CS 115 1.77 20789
12 x 8 CS 95 2.45 21233
14 x 7 CS 97 2.38 21264
17 x 6 CS 101 2.25 21379
30 x 4 CS 119 1.78 21566
22 x 5 CS 109 2.06 21771
20 x 6 HA 104.8 2.21 21909
31 x 4 CS 123 1.79 22344
18 x 6 CS 107 2.28 22860
23 x 5 CS 114 2.08 22885
16 x 7 HA 103.1 2.43 22950
32 x 4 CS 127 1.79 23121
15 x 7 CS 104 2.43 23130
13 x 8 CS 103 2.52 23492
12 x 9 HA 101.9 2.62 23805
33 x 4 CS 131 1.80 23900
24 x 5 CS 119 2.09 24001
19 x 6 CS 113 2.31 24346
14 x 8 HA 105.88 2.59 24548
34 x 4 CS 135 1.80 24678
24 x 6 HA 118.9 2.21 24880
16 x 7 CS 111 2.48 25006
12 x 9 CS 107 2.62 25025
25 x 5 CS 124 2.11 25118
35 x 4 CS 139 1.81 25456
14 x 8 CS 111 2.59 25771
20 x 6 CS 119 2.34 25835
36 x 4 CS 143 1.81 26235
26 x 5 CS 129 2.12 26237
17 x 7 CS 118 2.52 26892
37 x 4 CS 147 1.82 27014
21 x 6 CS 125 2.37 27328
27 x 5 CS 134 2.13 27356
12 x 10 HA 113.9 2.78 27706
13 x 9 CS 116 2.71 27726
38 x 4 CS 151 1.82 27793
15 x 8 CS 119 2.65 28069
16 x 8 HA 119.1 2.68 28286
28 x 5 CS 139 2.14 28476
20 x 7 HA 124.8 2.53 28490
39 x 4 CS 155 1.83 28573
18 x 7 CS 125 2.56 28786

Note: Not all sizes shown may be structurally available.


Designs are dependent on fill height.
TITLE PLANT STATE .
SECTION PAGE DATE

Bridge Products - Full Flow Constants All Plants TX 6.11 01-25-10


HEIDELBERGCEMENT Group
Bridge Products
Size / Type Equivalent Area Hydraulic K
Size Radius

22 x 6 CS 131 2.39 28825


12 x 10 CS 119 2.78 28927
14 x 9 HA 119.88 2.79 29233
40 x 4 CS 159 1.83 29352
28 x 6 HA 139.16 2.26 29524
29 x 5 CS 144 2.15 29597
23 x 6 CS 137 2.41 30324
16 x 8 CS 127 2.71 30382
14 x 9 CS 125 2.79 30457
19 x 7 CS 132 2.60 30687
30 x 5 CS 149 2.16 30719
24 x 6 CS 143 2.43 31825
31 x 5 CS 154 2.17 31841
13 x 10 CS 129 2.88 32092
20 x 7 CS 139 2.63 32595
17 x 8 CS 135 2.76 32709
12 x 11 CS 131 2.92 32922
24 x 7 HA 142.9 2.57 32955
32 x 5 CS 159 2.18 32964
15 x 9 CS 134 2.86 33212
25 x 6 CS 149 2.45 33329
16 x 9 HA 135.1 2.91 33871
14 x 10 HA 133.88 2.98 34076
33 x 5 CS 164 2.19 34087
21 x 7 CS 146 2.66 34508
26 x 6 CS 155 2.47 34834
18 x 8 CS 143 2.81 35048
34 x 5 CS 169 2.20 35212
14 x 10 CS 139 2.97 35294
20 x 8 HA 144.8 2.82 35520
16 x 9 CS 143 2.93 35989
35 x 5 CS 174 2.21 36336
27 x 6 CS 161 2.48 36342
22 x 7 CS 153 2.69 36426
13 x 11 CS 142 3.03 36568
12 x 12 CS 143 3.05 36996
19 x 8 CS 151 2.86 37398
36 x 5 CS 179 2.21 37461
28 x 6 CS 167 2.50 37851
23 x 7 CS 160 2.72 38349
15 x 10 CS 149 3.05 38530
37 x 5 CS 184 2.22 38587
17 x 9 CS 152 2.99 38785
14 x 11 HA 147.88 3.15 39054
28 x 7 HA 167.16 2.63 39191

Note: Not all sizes shown may be structurally available.


Designs are dependent on fill height.
TITLE PLANT STATE .
SECTION PAGE DATE

Bridge Products - Full Flow Constants All Plants TX 6.12 01-25-10


HEIDELBERGCEMENT Group
Bridge Products
Size / Type Equivalent Area Hydraulic K
Size Radius

29 x 6 CS 173 2.51 39361


16 x 10 HA 151.1 3.12 39666
38 x 5 CS 189 2.23 39712
20 x 8 CS 159 2.90 39757
14 x 11 CS 153 3.13 40263
24 x 7 CS 167 2.75 40275
39 x 5 CS 194 2.23 40839
30 x 6 CS 179 2.53 40873
13 x 12 CS 155 3.17 41140
18 x 9 CS 161 3.05 41598
24 x 8 HA 166.9 2.89 41662
16 x 10 CS 159 3.13 41795
40 x 5 CS 199 2.24 41965
21 x 8 CS 167 2.94 42124
25 x 7 CS 174 2.77 42205
31 x 6 CS 185 2.54 42386
20 x 9 HA 164.8 3.09 42935
32 x 7 HA 183.72 2.62 42946
32 x 6 CS 191 2.55 43900
15 x 11 CS 164 3.23 44000
26 x 7 CS 181 2.79 44139
19 x 9 CS 170 3.10 44426
22 x 8 CS 175 2.97 44499
17 x 10 CS 169 3.20 45086
14 x 12 CS 167 3.29 45344
33 x 6 CS 197 2.56 45416
16 x 11 HA 167.1 3.32 45643
27 x 7 CS 188 2.81 46075
23 x 8 CS 183 3.01 46881
34 x 6 CS 203 2.58 46932
20 x 9 CS 179 3.15 47267
16 x 11 CS 175 3.31 47774
28 x 7 CS 195 2.83 48014
18 x 10 CS 179 3.26 48398
35 x 6 CS 209 2.59 48449
24 x 8 CS 191 3.04 49269
15 x 12 CS 179 3.39 49600
28 x 8 HA 195.16 2.98 49653
29 x 7 CS 202 2.85 49956
36 x 6 CS 215 2.60 49967
21 x 9 CS 188 3.20 50120
20 x 10 HA 184.8 3.34 50681
24 x 9 HA 190.9 3.20 50913
37 x 6 CS 221 2.61 51486
17 x 11 CS 186 3.39 51580

Note: Not all sizes shown may be structurally available.


Designs are dependent on fill height.
TITLE PLANT STATE .
SECTION PAGE DATE

Bridge Products - Full Flow Constants All Plants TX 6.13 01-25-10


HEIDELBERGCEMENT Group
Bridge Products
Size / Type Equivalent Area Hydraulic K
Size Radius

25 x 8 CS 199 3.07 51662


19 x 10 CS 189 3.33 51731
30 x 7 CS 209 2.87 51899
22 x 9 CS 197 3.24 52984
38 x 6 CS 227 2.61 53006
31 x 7 CS 216 2.89 53845
16 x 12 CS 191 3.48 53903
26 x 8 CS 207 3.10 54060
39 x 6 CS 233 2.62 54526
32 x 8 HA 215.72 2.99 55033
20 x 10 CS 199 3.38 55082
18 x 11 CS 197 3.47 55416
32 x 7 CS 223 2.90 55793
23 x 9 CS 206 3.28 55857
40 x 6 CS 239 2.63 56047
27 x 8 CS 215 3.12 56462
33 x 7 CS 230 2.92 57742
17 x 12 CS 203 3.57 58246
21 x 10 CS 209 3.44 58448
36 x 8 HA 232.41 2.94 58622
20 x 11 HA 204.8 3.57 58717
24 x 9 CS 215 3.32 58738
28 x 8 CS 223 3.15 58869
19 x 11 CS 208 3.54 59278
34 x 7 CS 237 2.93 59694
24 x 10 HA 214.9 3.48 60640
28 x 9 HA 223.16 3.30 60812
29 x 8 CS 231 3.17 61279
25 x 9 CS 224 3.35 61628
35 x 7 CS 244 2.95 61646
22 x 10 CS 219 3.49 61829
18 x 12 CS 215 3.65 62626
20 x 11 CS 219 3.60 63163
36 x 7 CS 251 2.96 63600
30 x 8 CS 239 3.19 63693
26 x 9 CS 233 3.39 64524
23 x 10 CS 229 3.53 65223
37 x 7 CS 258 2.97 65556
31 x 8 CS 247 3.21 66110
19 x 12 CS 227 3.73 67039
21 x 11 CS 230 3.66 67069
27 x 9 CS 242 3.42 67427
38 x 7 CS 265 2.98 67512
32 x 9 HA 247.72 3.34 67999
32 x 8 CS 255 3.23 68530

Note: Not all sizes shown may be structurally available.


Designs are dependent on fill height.
TITLE PLANT STATE .
SECTION PAGE DATE

Bridge Products - Full Flow Constants All Plants TX 6.14 01-25-10


HEIDELBERGCEMENT Group
Bridge Products
Size / Type Equivalent Area Hydraulic K
Size Radius

24 x 10 CS 239 3.58 68628


39 x 7 CS 272 2.99 69470
28 x 9 CS 251 3.45 70336
24 x 11 HA 238.9 3.75 70786
33 x 8 CS 263 3.25 70953
22 x 11 CS 241 3.72 70994
40 x 7 CS 279 3.01 71428
20 x 12 CS 239 3.80 71482
25 x 10 CS 249 3.62 72045
28 x 10 HA 251.16 3.61 72584
36 x 9 HA 268.41 3.31 73236
29 x 9 CS 260 3.47 73250
34 x 8 CS 271 3.27 73378
23 x 11 CS 252 3.77 74936
26 x 10 CS 259 3.66 75471
35 x 8 CS 279 3.29 75806
21 x 12 CS 251 3.87 75951
30 x 9 CS 269 3.50 76170
36 x 8 CS 287 3.31 78236
24 x 11 CS 263 3.82 78893
27 x 10 CS 269 3.69 78906
31 x 9 CS 278 3.53 79094
42 x 9 HA 296.76 3.25 79930
22 x 12 CS 263 3.94 80443
37 x 8 CS 295 3.32 80667
32 x 10 HA 279.72 3.67 81745
32 x 9 CS 287 3.55 82022
28 x 10 CS 279 3.73 82349
25 x 11 CS 274 3.87 82864
38 x 8 CS 303 3.34 83101
28 x 11 HA 279.16 3.90 84901
33 x 9 CS 296 3.57 84954
23 x 12 CS 275 4.00 84958
39 x 8 CS 311 3.35 85536
29 x 10 CS 289 3.76 85799
26 x 11 CS 285 3.91 86848
34 x 9 CS 305 3.60 87890
40 x 8 CS 319 3.36 87973
36 x 10 HA 304.41 3.66 88813
30 x 10 CS 299 3.79 89257
24 x 12 CS 287 4.05 89492
35 x 9 CS 314 3.62 90829
27 x 11 CS 296 3.96 90844
31 x 10 CS 309 3.82 92721
36 x 9 CS 323 3.64 93771

Note: Not all sizes shown may be structurally available.


Designs are dependent on fill height.
TITLE PLANT STATE .
SECTION PAGE DATE

Bridge Products - Full Flow Constants All Plants TX 6.15 01-25-10


HEIDELBERGCEMENT Group
Bridge Products
Size / Type Equivalent Area Hydraulic K
Size Radius

25 x 12 CS 299 4.11 94044


28 x 11 CS 307 4.00 94851
32 x 11 HA 311.72 3.99 96187
32 x 10 CS 319 3.85 96190
37 x 9 CS 332 3.66 96716
28 x 12 HA 307.16 4.18 97705
42 x 10 HA 338.76 3.63 98161
26 x 12 CS 311 4.16 98613
29 x 11 CS 318 4.03 98868
38 x 9 CS 341 3.67 99664
33 x 10 CS 329 3.88 99666
39 x 9 CS 350 3.69 102615
30 x 11 CS 329 4.07 102894
34 x 10 CS 339 3.90 103146
27 x 12 CS 323 4.20 103198
36 x 11 HA 340.41 4.00 105255
40 x 9 CS 359 3.71 105568
35 x 10 CS 349 3.93 106631
31 x 11 CS 340 4.10 106929
28 x 12 CS 335 4.25 107796
36 x 10 CS 359 3.95 110120
32 x 11 CS 351 4.14 110971
32 x 12 HA 343.72 4.29 111257
29 x 12 CS 347 4.29 112407
37 x 10 CS 369 3.98 113614
48 x 10 HA 387.22 3.71 113946
33 x 11 CS 362 4.17 115021
30 x 12 CS 359 4.33 117030
38 x 10 CS 379 4.00 117111
42 x 11 HA 380.76 3.99 117524
34 x 11 CS 373 4.20 119078
39 x 10 CS 389 4.02 120612
31 x 12 CS 371 4.37 121664
36 x 12 HA 376.41 4.32 122477
35 x 11 CS 384 4.23 123141
40 x 10 CS 399 4.04 124117
32 x 12 CS 383 4.41 126308
32 x 13 HA 375.72 4.57 126893
36 x 11 CS 395 4.26 127209
33 x 12 CS 395 4.45 130962
37 x 11 CS 406 4.28 131284
38 x 11 CS 417 4.31 135364
34 x 12 CS 407 4.48 135624
48 x 11 HA 435.22 4.09 136616
42 x 12 HA 422.76 4.34 137917

Note: Not all sizes shown may be structurally available.


Designs are dependent on fill height.
TITLE PLANT STATE .
SECTION PAGE DATE

Bridge Products - Full Flow Constants All Plants TX 6.16 01-25-10


HEIDELBERGCEMENT Group
Bridge Products

Size / Type Equivalent Area Hydraulic K


Size Radius

39 x 11 CS 428 4.33 139448


35 x 12 CS 419 4.51 140295
36 x 13 HA 412.41 4.63 140410
40 x 11 CS 439 4.35 143537
36 x 12 CS 431 4.55 144974
37 x 12 CS 443 4.58 149660
38 x 12 CS 455 4.60 154353
36 x 14 HA 448.41 4.92 158989
39 X 12 CS 467 4.63 159052
42 x 13 HA 464.76 4.67 159249
40 X 12 CS 479 4.66 163757
42 x 14 HA 506.76 5.00 181443

Note: Not all sizes shown may be structurally available.


Designs are dependent on fill height.
TITLE PLANT STATE .
SECTION PAGE DATE

Bridge Products - Full Flow Constants All Plants TX 6.17 01-25-10


HEIDELBERGCEMENT Group
Precast Drainage Structures

"X" "Y" 8"

6"
12"
6"
"H"

"D"
"D

Pipe I.D.
.

"
I.D
pe "H"
Pi
"C" "C"

"B" 30"

18"

"A"
4"
(Min.)

"W" 6"

End Elevation Side Elevation

8" Basic Dimensions


"X"
Pipe Approx.
Dia. "A" "B" "C" "D" "H" "W" "X" "Y" Weight
"D" (In.) (In.) (In.) (In.) (In.) (In.) (In.) (In.) (In.) (Lbs.)
12 12.00 6.00 12.00 17.00 30.00 48.875 35.00 24.00 2,100
Pipe I.D.
15 12.00 6.00 12.00 20.50 30.00 48.875 35.00 24.00 2,100
18 12.00 6.00 12.00 24.00 30.00 48.875 35.00 24.00 2,100

21 12.00 6.00 12.00 27.50 36.00 69.750 42.00 36.00 3,400


24 12.00 6.00 12.00 31.00 36.00 69.750 42.00 36.00 3,400

27 12.00 6.00 12.00 35.00 42.00 90.000 49.00 48.00 4,900


30 12.00 6.00 12.00 38.50 42.00 90.000 49.00 48.00 4,900
"Y"
33 12.00 6.00 12.00 42.00 60.00 111.500 56.00 60.00 6,700
36 12.00 6.00 12.00 45.50 60.00 111.500 56.00 60.00 6,700

6" 42 9.00 9.00 18.00 52.50 63.00 153.000 70.00 84.00 14,500
48 9.00 9.00 18.00 59.50 63.00 153.000 70.00 84.00 14,500
"W"

Plan View

Note:
1.) All exposed corners shall be chamfered 3/4".
2.) Minimum reinforcing shall be #4 @ 6" (grade 60) or the equivalent
steel area provided in the form of welded wire fabric.
3.) Concrete for precast (steel formed) sections shall be a minimum of
CL 'A" (3,000 psi).
4.) At the option and expense of the contractor, the next larger size of -No Scale-
headwall may be furnished as long as the "D" dimension cast is that All dimensions subject to allowable
of the required size of pipe. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Precast Headwall - (Type B) All Plants TX 7.1 01-25-10


For Reinforced Concrete Pipe HEIDELBERGCEMENT Group
Precast Drainage Structures

C C
A

L D L

Type 1 Typical Top View of


Upstream Sloped End
Section
C
A

L D

Type 2

Upstream
C
Section - Typical
A

L D

Type 3

Downstream
C
Section - Typical
A

L D

Type 4

Note:
1.) See next page for control dimensions.
2.) "Slope Line" is finished by contractor.
3.) Rough cut slope will be approximately 3" wide, except circumferential cut at -No Scale-
end of slope will be perpendicular to wall and 1" wide. All dimensions subject to allowable
4.) All measurements shown are O.D. of pipe-rough cuts perpendicular to wall. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Reinforced Concrete Pipe Grand Prairie


TX 7.2 01-25-10
Houston
Sloped End Sections HEIDELBERGCEMENT Group
Precast Drainage Structures

Standard Dimensions
Wall Outside No. Jts.
Size Thk. Diam Slope / Jt. Lt. Type A B C D L
(In.) (In.) (In.) (In.) (In.) (In.) (In.) (In.)

3:1 1 / 6' 1 2 6 13 1/2 25 1/2 46 1/2


15 2 19 4:1 2 / 4' 2 2 6 18 34 62
6:1 2 / 6' 2 2 6 27 51 93

3:1 1 / 8' 1 2 1/2 6 21 31 1/2 64 1/2


18 2 1/ 23 4:1 1 / 8' 1 2 1/2 6 12 26 70
2
6:1 2 / 6' 2 2 1/2 6 18 39 105

3:1 1 / 8' 1 2 3/4 6 16 1/2 26 1/4 69 3/4


21 2 3/ 26 1/ 4:1 2 / 6' 2 2 3/4 6 30 43 101
4 2
6:1 2 / 8' 2 2 3/4 6 33 52 1/2 139 1/2

3:1 1 / 8' 1 3 9 12 30 66
24 3 30 4:1 2 / 6' 2 3 9 24 48 96
6:1 2 / 8' 2 3 9 24 60 132

3:1 2 / 6' 2 3 1/4 9 1/4 31 1/2 49 1/2 94 1/2


27 3 1/ 33 1/ 4:1 2 / 6' 2 3 1/4 9 1/4 18 42 102
4 2
6:1 3 / 6' 3 3 1/4 9 1/4 27 63 153

3:1 2 / 6' 2 3 1/2 9 1/2 27 45 99


30 3 1/ 37 4:1 2 / 8' 2 3 1/2 9 1/2 36 60 132
2
6:1 3 / 6' 3 3 1/2 9 1/2 18 54 162

3:1 2 / 6' 2 3 3/4 9 3/4 22 1/2 40 1/2 103 1/2


33 3 3/ 40 1/ 4:1 2 / 8' 2 3 3/4 9 3/4 30 54 138
4 2
6:1 3 / 8' 3 3 3/4 9 3/4 45 69 219

3:1 2 / 6' 2 4 10 18 36 108


36 4 44 4:1 2 / 8' 2 4 10 24 48 144
6:1 3 / 8' 3 4 10 36 72 216

3:1 2 / 8' 2 4 1/2 10 1/2 33 51 141


42 4 1/ 51 4:1 2 / 8' 2 4 1/2 10 1/2 12 36 156
2
6:1 3 / 8' 3 4 1/2 101/2 18 54 234

3:1 2 / 8' 2 5 11 24 42 150


48 5 58 4:1 3 / 8' 3 5 11 48 72 216
6:1 4 / 8' 4 5 11 48 84 300

3:1 2 / 8' 2 5 1/2 11 1/2 15 33 159


54 5 1/ 65 4:1 3 / 8' 3 5 1/2 11 1/2 36 60 228
2
6:1 4 / 8' 4 5 1/2 111/2 30 66 318

3:1 3 / 6' 3 6 12 18 36 180


60 6 72 4:1 3 / 8' 3 6 12 24 48 240
6:1 4 / 8' 4 6 12 12 48 336

Note:
For slopes and sizes not listed contact manufacturer.

TITLE PLANT STATE .


SECTION PAGE DATE

Control Dimensions Grand Prairie


TX 7.3 01-25-10
RCP - Sloped End Sections Houston
HEIDELBERGCEMENT Group
Precast Drainage Structures

12" "L"
End of payment for pipe
5" 7"

5"

Min Dimension
Is Pipe I.D.
"D"
Pipe I.D.

"H"

5"

Plan

4"

Slope
"J"
Pipe I.D.

"E"
"D"
6"

5"

6" Toe Wall Optional


5" 7" "M"
6"

12" "L"

Longitudinal Elevation

Basic Dimensions
Pipe
Dia. Slope "D" "E" "H" "J" "L" "M" Weight
(In.) (In.) (In.) (In.) (In.) (In.) (In.) (Lbs.)
"D

.
I.D
"

3:1 17.000 17.500 28.00 26.250 34.500 0.75 1,328


p e
Pi 12 4:1 17.000 17.500 28.00 26.250 46.000 0.75 1,558
6:1 17.000 17.500 28.00 26.250 69.000 0.75 2,017

3:1 20.500 17.500 28.00 26.250 34.500 0.75 1,243


15 4:1 20.500 17.500 28.00 26.250 46.000 0.75 1,472
6:1 20.500 17.500 28.00 26.250 69.000 0.75 1,831

5" 5" 3:1 24.000 21.000 30.00 30.000 45.000 1.00 1,751
18 4:1 24.000 21.000 30.00 30.000 60.000 1.00 2,018
"H" 6:1 24.000 21.000 30.00 30.000 90.000 1.00 2,831

End View 3:1 31.000 27.500 37.00 37.000 64.500 1.50 2,831
24 4:1 31.000 27.500 37.00 37.000 86.000 1.50 3,596
6:1 31.000 27.500 37.00 37.000 129.000 1.50 4,818
Note: 3:1 38.500 34.500 41.00 44.500 85.500 2.25 4,092
1.) The Safety End Treatment option shown on this sheet should only 30 4:1 38.500 34.500 41.00 44.500 114.000 2.25 5,082
6:1 38.500 34.500 41.00 44.500 171.000 2.25 7,060
be utilized in the following instances:
A.) On cross-drainage structures for 36" or smaller diameter pipes. 3:1 45.500 41.000 47.00 51.500 105.000 2.50 5,544
B.) On parallel-drainage structures for 30" or smaller pipes. 36 4:1 45.500 41.000 47.00 51.500 140.000 2.50 6,827
6:1 45.500 41.000 47.00 51.500 210.000 2.50 8,722
2.) Cross & Parallel drainage structures larger than the requirements
listed above shall utilize other safety end treatment designs shown
elsewhere in the plans.
3.) All exposed corners shall be chamfered 3/4".
4.) Manufacture of this product shall conform to the requirements of Item
467 except that minimum reinforcing shall be #4 @ 6" (Grade 40) or
#4 @ 9" (Grade 60) each way or 6 x 6 - W12 x W12 or 5 x 5 - W10 x
W10 welded wire fabric.
5.) Concrete for precast (steel formed) sections shall be a minimum of
Class "C" (4,000 psi).
6.) At the option and expense of the contractor, the next larger size of -No Scale-
Safety End Treatment may be furnished as long as the "D" All dimensions subject to allowable
dimension cast is that of the required size of pipe. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Precast Safety End Treatment Grand Prairie


TX 7.4 01-25-10
Houston
For Reinforced Concrete Pipe HEIDELBERGCEMENT Group
Precast Drainage Structures
"D"

"C" "J"

1"

Pipe I.D.
"R

"E"
Plan View

Pipe Length Computed to


Here. - See Note Below.
End of payment
"C"
for pipe.
"T"

Slope = "X" to "Y"


"X"
"Y"
Pipe I.D.

Pipe
Diameter
Reinforcement

"K"
Groove End on Outlet End Section

"T"
"T"

End View Tongue End on Inlet End Section

Longitudinal Elevation

Standard Dimensions
Wall
Size T Slope R1 C D E J K Wt.
(In.) (In.) (In.) (Ft.) (Ft.) (Ft.) (Ft.) (In.) (lbs.)

18 2 1/2 3:1 12 3.83 6.08 3.00 2.25 9 1,400


24 3 3:1 14 2.50 6.12 4.00 3.63 9 1/2 2,000

30 3 1/2 3:1 15 1.66 6.16 5.00 4.50 12 2,920


36 4 3:1 20 2.90 8.15 6.00 5.25 15 5,400

-No Scale-
Note:
All dimensions subject to allowable
1.) Length of pipe to be reduced by the "C" demension for each end section. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Precast Culvert End Sections Grand Prairie TX 7.5 01-25-10


For Reinforced Concrete Pipe HEIDELBERGCEMENT Group
Precast Drainage Structures

12" 12"

12" 1"

2 1/2"
16 1/2"
10 1/4"

2 1/4" 10 1/4" 2 1/4"

12"

2 1/2"

16 1/2"

10" Thin Wall K.O.'s

Materials & Features


MAXIMUM PIPE SIZE: 8" PVC

CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185

CAST IRON FRAME & GRATE per ASTM A 48; Class 30/35

GRATE WEIGHT: 18 Lbs.

CATCH BASIN WEIGHT: 250 Lbs.


-No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Grand Prairie
#12 Catch Basin Houston
TX 8.1 01-25-10
HEIDELBERGCEMENT Group
Precast Drainage Structures

14" 14"

18" 1"

3"
17"
14"
2 1/2" 12" 2 1/2"

18"

3"

17"

12" Thin Wall K.O.'s

Materials & Features


MAXIMUM PIPE SIZE: 10" PVC

CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185

CAST IRON FRAME & GRATE per ASTM A 48; Class 30/35

GRATE WEIGHT: 38 Lbs. -No Scale-


All dimensions subject to allowable
CATCH BASIN WEIGHT: 475 Lbs. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Grand Prairie
#14 Catch Basin Houston
TX 8.2 01-25-10
HEIDELBERGCEMENT Group
Precast Drainage Structures

4" Typ.

28" 24"

18"
16"
Th
in
Kn wall 18"
oc
All kou
Sid ts 4" Thick Floor
es 3 3/4" (Typ.)

24" 24"

Materials & Features


MAXIMUM PIPE SIZE: 16" PVC

CONCRETE: 5,000 PSI.

REINFORCED TO H20 LOADING.

MAXIMUM RCP: 12".

RISER SECTIONS AVAILABLE.

GRATE: 18" x 18" CAST IRON. 1 ft2 clear opening. -No Scale-
All dimensions subject to allowable
WEIGHT: 675 LBS. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

#18 Catch Basin (Surface Grate Inlet)


Austin TX 8.3 01-25-10
City of Austin HEIDELBERGCEMENT Group
Precast Drainage Structures

20" 20"

1 1/2"

26"
20"
p.)
(Ty
4"

2' & 3'


Depth
Available

4"

26"

18" Thin Wall K.O.'s

Materials & Features


MAXIMUM PIPE SIZE: 12" RCP, 15" PVC

CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185


CAST IRON FRAME & GRATE per ASTM A 48; Class 30/35
GRATE WEIGHT: 78 Lbs.
CATCH BASIN WEIGHT: -No Scale-
2' - 800 Lbs. All dimensions subject to allowable
3' - 1,100 Lbs. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Grand Prairie
#20 Catch Basin Houston TX 8.4 01-25-10
HEIDELBERGCEMENT Group
Precast Drainage Structures

24" 24"

2"

22 1/2"
31 1/2"

4" (Typ.)
12", 18"

31 1/2"
22 1/2"

2.5', 3', 4' &


Materials & Features 5' Depth
Available
MAXIMUM PIPE SIZE: 18" I.D. R.C.P.

CONCRETE: 5,000 PSI


REINFORCING: per ASTM A-615 or A-185

CAST IRON FRAME & GRATE


per ASTM A 48; Class 30/35

GRATE WEIGHT: 100 Lbs.


4"
CATCH BASIN WEIGHT:
2.5' ........... 1,580 Lbs.
3' ........... 2,500 Lbs.
4' ........... 3,420 Lbs. 31 1/2"
5' ........... 4,350 Lbs.

EXTENSION WEIGHT: Thin Wall K.O.'s


12" ........... 500 Lbs.
18" ........... 750 Lbs.
-No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Grand Prairie
#24 Catch Basin Houston TX 8.5 01-25-10
HEIDELBERGCEMENT Group
Precast Drainage Structures

26" 26"

2"

24"
36"

6" (Typ.)
12", 18"

36"
24"

2', 3' & 4'


Materials & Features Depth
Available
MAXIMUM PIPE SIZE: 18" I.D. R.C.P.

CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185

CAST IRON FRAME & GRATE


per ASTM A 48; Class 30/35

GRATE WEIGHT: 100 Lbs.


6"
CATCH BASIN WEIGHT:
2' ........... 1,580 Lbs.
3' ........... 2,500 Lbs.
4' ........... 3,420 Lbs. 36"

EXTENSION WEIGHT:
12" ........... 500 Lbs. Thin Wall K.O.'s
18" ........... 750 Lbs.

-No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

#26 Catch Basin Waco TX 8.6 01-25-10


HEIDELBERGCEMENT Group
Precast Drainage Structures

31 1/2" 31 1/2"

2"

6"

30"
3'-6"

6"

1' - 0"

6"

30"
3' - 6"

6"

3' - 0"

6"

Materials & Features


MAXIMUM PIPE SIZE: 24" I.D. R.C.P.

CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185


Thin Wall K.O.'s
CAST IRON FRAME & GRATE per ASTM A 48; Class 30/35

GRATE WEIGHT: 275 Lbs.

CATCH BASIN WEIGHT:(3' - 0" I.D.) 3,900 Lbs.

EXTENSION WEIGHT:
-No Scale-
12" ........... 900 Lbs. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

30" x 30" Inlet Grand Prairie TX 8.7 01-25-10


HEIDELBERGCEMENT Group
Precast Drainage Structures

30" 30"

1 3/8"
Cast Iron Frame
and Grate

6"
3' - 6"
30" 6"
30"
3'-6"

6"
1'-0" 1'-0"

Varies

6"

6"
30"
3' - 6"
Section View
6"

Varies

Materials & Features


MAXIMUM PIPE SIZE: 24" I.D. R.C.P. 6"

CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185

CAST IRON FRAME & GRATE per ASTM A 48; Class 30/35

GRATE WEIGHT: 275 Lbs. 30" Dia. K.O.'s


CATCH BASIN WEIGHT: 3,900 Lbs. -No Scale-
All dimensions subject to allowable
CATCH BASIN RISER WEIGHT: 900 Lbs. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

30" x 30" Catch Basin


Houston TX 8.8 01-25-10
w/ Type "A" Grated Inlet HEIDELBERGCEMENT Group
Precast Drainage Structures

4' - 0" 4' - 0"

6"

3' x 3' Cast Iron Frame 36" TXP


& Grate Cast-In

6"
7"

6" 3' - 0" 3' - 0"

6"

3' - 6"

3' - 6"

6"

6" 3' - 0" 6"


6"

Materials & Features K.O.'s as Required


CONCRETE: 5,000 PSI
By Customer

REINFORCING: per ASTM A-615 or A-185


H-20 LOADING
MAXIMUM PIPE SIZE 30" I.D. R.C.P.
TOP SLAB WEIGHT: 1,180 Lbs.
-No Scale-
JUNCTION BOX WEIGHT: 4,810 Lbs.
All dimensions subject to allowable
EXTENSION SECTIONS AVAILABLE specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

3' x 3' Standard Catch Basin Grand Prairie TX 8.9 01-25-10


HEIDELBERGCEMENT Group
Precast Drainage Structures
48"

Wye Inlet Top


ed
quir
Re 48"
As

Extension

48" 48"

Top View
6"
48"

Slab Top with


35" Grate Assembly

5 1/2" 18"

48" 48"

6" 6"
Front View
Slab Top
(Ref. Note 1)
Item Height Approx.
in Isometric (Inches) Weight
Grate
View (Lbs.)

Wye Inlet Top 18 2,208

Extension 12 1,050
15 1,313
18 1,575
21 1,838
24 2,100

Slab Top 6 1,185


Box with
Grate 3 1/4 270 Knock-Outs

Box Varies

Isometric View

Note: -No Scale-


All dimensions subject to allowable
1.) Customer to specify opening size or cast iron ring and cover.
specification tolerances.
TITLE PLANT STATE .
SECTION PAGE DATE

Grand Prairie
Top Options for 3' x 3' Precast Box Houston TX 9.1 01-25-10
HEIDELBERGCEMENT Group
Precast Drainage Structures
60"

Wye Inlet Top


ed
uir
Req 60"
As

Extension

60" 60"
Top View
60"

47" 6"
Slab Top with
5 1/2" 18"
Grate Assembly

6"
60" 60"
Front View

Item Height Approx. Slab Top


(Ref. Note 1) 6"
in Isometric (Inches) Weight
View (Lbs.)
Grate
Wye Inlet Top 18 3,430

Extension 12 1,350
15 1,688
18 2,025
21 2,363
24 2,700

Slab Top 6 1,340

Grate 3 1/4 433 Box with


Knock-Outs
Box Varies

Isometric View

Note: -No Scale-


1.) Customer to specify opening size or cast iron ring and cover. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Grand Prairie
Top Options for 4' x 4' Precast Box Houston TX 9.2 01-25-10
HEIDELBERGCEMENT Group
Precast Drainage Structures

72"

Wye Inlet Top

d
uire
Req 72"
As
Extension
(Ref: Note 1)

Customer to specify Opening Size or


Cast Iron Ring and Cover.

Top View
72" 72"

72"

6"
12" Slab Top
6"

Front View Grate

Item Height Approx.


in Isometric (Inches) Weight
View (Lbs.)

Wye Inlet Top 12"

Slab Top 6 4,400

Grate 4 1/2" 850

Box Varies
Box with
Knock-Outs

Isometric View

-No Scale-
Note: All dimensions subject to allowable
1.) For information on extensions contact your Hanson Representative. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

5' x 5' Precast Box Grand Prairie TX 9.3 01-25-10


HEIDELBERGCEMENT Group
Precast Drainage Structures

Customer to Specify
Opening Size or
Cast-In Ring & Cover

7' - 0" 7' - 0"

8"

Slab Top
9"

8"

6"

6' - 0" 7' - 0"


Varies to
5' - 0"
6"

8"
Varies to
5' - 0"

6" 6' - 0" 6"

8"

Junction Box

Materials & Features


MAXIMUM PIPE SIZE 48" RCP
Holes as Required
By Customer
CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185
H-20 LOADING
TOP SLAB WEIGHT: 5,600 Lbs.
JUNCTION BOX WEIGHT: 16,600 Lbs. (6' x 6' x 5')
-No Scale-
EXTENSION SECTIONS AVAILABLE All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

6' x 6' Standard Junction Box Grand Prairie


TX 9.4
Houston 01-25-10
With Variable Depths Waco HEIDELBERGCEMENT Group
Precast Drainage Structures

8' - 0" 8' - 0"

8"

Varies
to 8' - 0"

8"

Customer to Specify
Opening Size or
Cast-In Ring & Cover
8"

7' - 0" 7' - 0"

8"

Varies
to 8' - 0"

8"

Holes as Required
By Customer

Materials & Features


CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185
H-20 LOADING
TOP SECTION WEIGHT: 15,400 Lbs. (7' x 7' x 4' Top)
BOTTOM SECTION WEIGHT: 15,400 Lbs. (7' x 7' x 4' Bottom) -No Scale-
All dimensions subject to allowable
(6" Wall thickness at Grand Prairie) specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

7' x 7' Standard Junction Box Grand Prairie


9.5
Houston TX 01-25-10
With Variable Depths HEIDELBERGCEMENT Group
Precast Drainage Structures

9' - 4" 9' - 4"

8"

Varies
to 8' - 0"

8"

Customer to Specify
Opening Size or
Cast-In Ring & Cover
8"

8' - 0" 8' - 0"

8"

Varies
to 8' - 0"

8"

Holes as Required
By Customer

Materials & Features


CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185
H-20 LOADING
TOP SECTION WEIGHT: 26,000 Lbs. (8' x 8' x 5' - 8" Top)
-No Scale-
BOTTOM SECTION WEIGHT: 26,000 Lbs. (8' x 8' x 5' - 8" Bottom) All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

8' x 8' Standard Junction Box Grand Prairie


TX
Houston 9.6 01-25-10
With Variable Depths HEIDELBERGCEMENT Group
Precast Drainage Structures

11' - 4" 11' - 4"

9"

Varies
to 5' - 0"

8"

Customer to Specify
Opening Size or
Cast-In Ring & Cover
8"

10' - 0" 10' - 0"

8"

Varies
to 5' - 0"

9"

Materials & Features


CONCRETE: 5,000 PSI
REINFORCING: GRADE 60.
H-20 LOADING. K.O.'s as Required
CAST-IN RING AS SPECIFIED BY CUSTOMER. By Customer

BOTTOM WEIGHT: 2' ............. 23,000 Lbs.


3' ............. 27,250 Lbs.
4' ............. 31,500 Lbs.
5' ............. 35,800 Lbs.

TOP WEIGHT: 2' ............. 23,000 Lbs.


3' ............. 27,250 Lbs.
4' ............. 31,500 Lbs.
5' ............. 35,800 Lbs. -No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

10' x 10' Standard Junction Box Alvarado 9.7


TX 01-25-10
With Variable Depths HEIDELBERGCEMENT Group
Precast Drainage Structures

13' - 4" 13' - 4"

9"

Varies
to 6' - 0"

8"

Customer to Specify
Opening Size or
Cast-In Ring & Cover
8"

12' - 0" 12' - 0"

8"

Varies
to 6' - 0"

9"

Materials & Features


CONCRETE: 5,000 PSI
REINFORCING: GRADE 60.
H-20 LOADING.
CAST-IN RING AS SPECIFIED BY CUSTOMER. K.O.'s as Required
By Customer
BOTTOM WEIGHT: 2' ............. 30,150 Lbs.
3' ............. 35,200 Lbs.
4' ............. 40,300 Lbs.
5' ............. 45,800 Lbs.
6' ............. 50,000 Lbs.

TOP WEIGHT: 2' ............. 30,150 Lbs.


3' ............. 35,200 Lbs.
4' ............. 40,300 Lbs.
5' ............. 45,800 Lbs. -No Scale-
6' ............. 50,000 Lbs. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

12' x 12' Standard Junction Box TX


Alvarado 9.8 01-25-10
With Variable Depths HEIDELBERGCEMENT Group
Precast Drainage Structures

3' - 0"
4' - 0"
6"

Customer to Specify
6" Opening Size or
Cast-In Ring & Cover

2' - 0"
3' - 0"

6"

Varies
to 5' - 0"

6"

Holes as Required
By Customer
Materials & Features
CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185

H-20 LOADING

SLAB TOP WEIGHT: 920 Lbs.

BOTTOM SECTION WEIGHT: 3,600 Lbs. (bottom height = 3' - 0")


4,500 Lbs. (bottom height = 4' - 0")
5,400 Lbs. (bottom height = 5' - 0")
-No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

2' x 3' Junction Box Grand Prairie


Houston TX 9.9 01-25-10
With Variable Depths HEIDELBERGCEMENT Group
Precast Drainage Structures

3' - 6"
6' - 0"
6"

Customer to Specify
6" Opening Size or
Cast-In Ring & Cover

2' - 6"
5' - 0"

6"

Varies
to 5' - 0"

6"

Holes as Required
By Customer
Materials & Features
CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185

H-20 LOADING

SLAB TOP WEIGHT: 1,600 Lbs.

BOTTOM SECTION WEIGHT: 5,400 Lbs. (bottom height = 3' - 0")


6,675 Lbs. (bottom height = 4' - 0")
7,950 Lbs. (bottom height = 5' - 0")
-No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

2' - 6" x 5' Junction Box Grand Prairie


9.10
TX 01-25-10
With Variable Depths Houston
HEIDELBERGCEMENT Group
Precast Drainage Structures

4' - 0"
5' - 0"

6"

Varies
to 5' - 0"

6"

Customer to Specify
Opening Size or
Cast-In Ring & Cover

6"

3' - 0"
4' - 0"

6"

Varies
to 5' - 0"

6"

Holes as Required
By Customer
Materials & Features
CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185

H-20 LOADING

TOP SECTION WEIGHT: 7,500 Lbs. (3' x 4' x 5' Box)


-No Scale-
BOTTOM SECTION WEIGHT: 7,500 Lbs. (3' x 4' x 5' Box) All dimensions subject to allowable
SLAB TOP AVAILABLE specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

3' x 4' Standard Junction Box (2-Piece) Grand Prairie


9.11
Houston TX 01-25-10
With Variable Depths HEIDELBERGCEMENT Group
Precast Drainage Structures

5' - 0"
6' - 0"
6"

Varies
to 5' - 0"

Customer to Specify
Opening Size or
Cast-In Ring & Cover 6"

6"

4' - 0" 5' - 0"

6"

Varies
to 5' - 0"

6"

Materials & Features


CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185.

H-20 LOADING Holes as Required


By Customer
BOTTOM SECTION WEIGHT: 9,750 Lbs. (4' x 5' x 5' Box)

TOP SECTION WEIGHT: 9,750 Lbs. (4' x 5' x 5' Box)

CAST-IN RING AS SPECIFIED BY CUSTOMER.


-No Scale-
TOP SLAB AVAILABLE. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

4' x 5' Standard Junction Box (2-Piece) Grand Prairie 9.12


TX 01-25-10
With Variable Depths Houston
HEIDELBERGCEMENT Group
Precast Drainage Structures

5' - 0"
7' - 0"
6"

Varies
to 4' - 0"

Customer to Specify
Opening Size or
Cast-In Ring & Cover 6"

6"

4' - 0" 6' - 0"

6"

Varies
to 4' - 0"

6"

Materials & Features


CONCRETE: 5,000 PSI
REINFORCING: GRADE 60.
H-20 LOADING.
CAST-IN RING AS SPECIFIED BY CUSTOMER. K.O.'s as Required
By Customer
BOTTOM WEIGHT: 2' ............. 5,925 Lbs.
3' ............. 7,575 Lbs.
4' ............. 9,225 Lbs.

TOP WEIGHT: 2' ............. 5,925 Lbs.


3' ............. 7,575 Lbs. -No Scale-
4' ............. 9,225 Lbs. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

4' x 6' Standard Junction Box (2-Piece) 9.13


Alvarado TX 01-25-10
With Variable Depths HEIDELBERGCEMENT Group
Precast Drainage Structures

5' - 0"

6" 9' - 0"

Varies
to 6' - 0"

Customer to Specify
Opening Size or
Cast-In Ring & Cover
6" 6"

4' - 0"
8' - 0"

6"

Varies
to 6' - 0"

6"

Materials & Features


CONCRETE: 5,000 PSI Holes as Required
By Customer
REINFORCING: per ASTM A-615 or A-185
H-20 LOADING

TOP SECITON WEIGHT: 8,600 Lbs. (top height = 3' - 0")


BOTTOM SECTION WEIGHT: 8,600 Lbs. (bottom height = 3' - 0") -No Scale-
All dimensions subject to allowable
TOP SLAB AVAILABLE specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

4' x 8' Standard Junction Box Grand Prairie


TX 9.14 01-25-10
Houston
With Variable Depths HEIDELBERGCEMENT Group
Precast Drainage Structures

6' - 0"
8' - 0"
8"

Varies
to 6' - 0"

Customer to Specify
Opening Size or 6"
Cast-In Ring & Cover

6"

5' - 0"
7' - 0"

6"

Varies
to 6' - 0"

8"

Materials & Features


CONCRETE: 5,000 PSI Holes as Required
REINFORCING: per ASTM A-615 or A-185 By Customer
H-20 LOADING
TOP SECTION WEIGHT: 16,500 Lbs. (top height = 6' - 0")
BOTTOM SECTION WEIGHT: 16,500 Lbs. (bottom height = 6' - 0") -No Scale-
All dimensions subject to allowable
TOP SLAB AVAILABLE specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

5' x 7' Standard Junction Box 9.15


Grand Prairie TX 01-25-10
With Variable Depths HEIDELBERGCEMENT Group
Precast Drainage Structures

7' - 0"
9' - 0"
8"

Varies
to 5' - 0"

Customer to Specify
Opening Size or
Cast-In Ring & Cover 6"

6"

6' - 0" 8' - 0"

6"

Varies
to 5' - 0"

8"

Materials & Features


CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185.


Holes as Required
BOTTOM WEIGHT: 3' ................ 13,050 Lbs. By Customer
4' ................ 15,300 Lbs.
5' ................ 17,550 Lbs.

TOP WEIGHT: 3' ................ 13,050 Lbs.


4' ................ 15,300 Lbs.
5' ................ 17,550 Lbs. -No Scale-
All dimensions subject to allowable
CAST-IN RING AS SPECIFIED BY CUSTOMER. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

6' x 8' Standard Junction Box TX 9.16


Grand Prairie 01-25-10
With Variable Depths HEIDELBERGCEMENT Group
Precast Drainage Structures

7' - 0"

8" 13' - 0"

Varies
to 5' - 0"

Customer to Specify
Opening Size or
Cast-In Ring & Cover
6" 6"

6' - 0"
12' - 0"

6"

Varies
to 5' - 0"

8"

Materials & Features


CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185.

BOTTOM WEIGHT: 3' ................ 15,400 Lbs. Holes as Required


4' ................ 18,200 Lbs. By Customer
5' ................ 21,100 Lbs.

TOP WEIGHT: 3' ................ 15,400 Lbs.


4' ................ 18,200 Lbs.
5' ................ 21,100 Lbs. -No Scale-
All dimensions subject to allowable
CAST-IN RING AS SPECIFIED BY CUSTOMER. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

6' x 12' Standard Junction Box Grand Prairie


9.17
Houston TX 01-25-10
With Variable Depths HEIDELBERGCEMENT Group
Precast Drainage Structures

9' - 0" 11' - 0"

8"

Varies
to 4' - 0"

6"

Customer to Specify
Opening Size or
Cast-In Ring & Cover
6"

8' - 0" 10' - 0"

6"

Varies
to 4' - 0"

8"

Holes as Required
By Customer

Materials & Features


CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185
H-20 LOADING
TOP SECTION WEIGHT: 21,300 Lbs. (8' x 10' x 4' Box) -No Scale-
All dimensions subject to allowable
BOTTOM SECTION WEIGHT: 21,300 Lbs. (8' x 10' x 4' Box) specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

8' x 10' Standard Junction Box Grand Prairie TX 9.18 01-25-10


With Variable Depths HEIDELBERGCEMENT Group
Precast Drainage Structures

9' - 4"

8" 15' - 4"

Varies
to 4' - 0"

Customer to Specify
Opening Size or
Cast-In Ring & Cover
8" 8"

8' - 0"
14' - 0"

8"

Varies
to 4' - 0"

8"

Materials & Features


CONCRETE: 5,000 PSI
REINFORCING: GRADE 60.
H-20 LOADING.
CAST-IN RING AS SPECIFIED BY CUSTOMER.
K.O.'s as Required
BOTTOM WEIGHT: 2' ............. 23,650 Lbs. By Customer
3' ............. 28,300 Lbs.
4' ............. 33,000 Lbs.

TOP WEIGHT: 2' ............. 23,650 Lbs.


3' ............. 28,300 Lbs.
-No Scale-
4' ............. 33,000 Lbs. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

8' x 14' x 8' Standard Junction Box 9.19


Alvarado TX 01-25-10
With Variable Depths HEIDELBERGCEMENT Group
Precast Drainage Structures

Customer to Specify
Opening Size or
Cast-In Ring & Cover

7' - 0" 7' - 0"

8"

Slab Top
9"

8"

6"

6' - 0" 7' - 0"


6' - 0"

6"

8"
6' - 0"

6" 6' - 0" 6"

8"

Junction Box

Materials & Features


MAXIMUM PIPE SIZE 48" RCP
62" x 62" Thinwall
Knockout - 4 Sides
CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185
H-20 LOADING
TOP SLAB WEIGHT: 5,600 Lbs.
JUNCTION BOX WEIGHT: 16,600 Lbs. (6' x 6' x 6' Base Only)
-No Scale-
EXTENSION SECTIONS AVAILABLE All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Grand Prairie
6' x 6' x 6' Junction Box Houston TX 9.20 01-25-10
Waco HEIDELBERGCEMENT Group
Precast Drainage Structures
4' - 0"
6' - 0"

1' - 10"

Frame and Cover as


Required by City

4' - 0" 3' - 0"


5' - 0" 6' - 0"

20"

1' - 0"

5' - 8 1/2"

6"

6"

Section View

3' - 10 1/2"

Materials & Features


CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185


#3 Rebar Left Exposed for
MAXIMUM PIPE SIZE: 24" I.D. Gutter Tie-In
32" x 32" Thinwall K.O.'s
WEIGHT: Typ 4 Places
BASE 6,300 Lbs.
EXTENSION 1,350 Lbs.
TOP 3,600 Lbs.
11,250 Lbs. Total -No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

5' Curb Inlet w / 5.0' Invert w / 6" Wall 10.a.1 01-25-10


Grand Prairie TX
Dallas / Fort Worth HEIDELBERGCEMENT Group
Precast Drainage Structures
3' - 10"
6' - 4"

2' - 1"

Frame and Cover as


Required by City

20"

3' - 7"

5' - 8"

#3 Rebar Left Exposed


8" for Gutter Tie-In

32" x 32" Thinwall K.O.'s


8"
All Four Sides
Section View

Materials & Features


CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185

MAXIMUM PIPE SIZE: 24" I.D.

WEIGHT:
BASE & TOP ........... 14,700 Lbs. Total
-No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

5' Curb Inlet w / 5.0' Invert w / 8" Wall Alvarado TX 10.a.2 01-25-10
Dallas / Fort Worth HEIDELBERGCEMENT Group
Precast Drainage Structures
4' - 0"
7' - 0"

1' - 10"

Frame and Cover as


Required by City

20" 4' - 0" 3' - 0"


6' - 0" 7' - 0"

5' - 8 1/2"

1' - 0"

6"

6"

Section View

3' - 10 1/2"

Materials & Features


CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185


#3 Rebar Left Exposed
MAXIMUM PIPE SIZE: 24" I.D.
for Gutter Tie-In
32" x 32" Thinwall K.O.'s
WEIGHT:
BASE 7,000 Lbs.
Typ. 4 Places
EXTENSION 1,500 Lbs.
TOP 4,000 Lbs.
12,500 Lbs. Total -No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

6' Curb Inlet - Dallas / Fort Worth Grand Prairie TX 10.a.3 01-25-10
HEIDELBERGCEMENT Group
Precast Drainage Structures

"
-2
4' 7' -
4"

2' - 1"
Frame and Cover as
Required by City

3' - 7"
20"

#3 Rebar Cast In &


5' - 8"

Exposed for Gutter


Tie-in
3"
32" x 32" Thinwall K.O.'s
All Four Sides
8"

8"

Materials & Features.


CONCRETE: 5,000 PSI

REINFORCING: GRADE 60

MAXIMUM PIPE SIZE: 24" I.D.

WEIGHT: ........... 15,700 Lbs.


-No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

6' Curb Inlet w/ 5.0' Invert 10.a.4 01-25-10


Alvarado TX
Dallas / Fort Worth HEIDELBERGCEMENT Group
Precast Drainage Structures

4' - 0"

11' - 0"

Frame and Cover as


1' - 10"
Required by City

4' - 0" 3' - 0"

10' - 0" 11' - 0"


17"

5' - 8 1/2" 1' - 0"

6"
6"
or
8"
Section View

Materials & Features 3' - 10 1/2"


CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185


#3 Rebar Left Exposed
MAXIMUM PIPE SIZE: 24" I.D. for Gutter Tie-In
WEIGHT:
BASE 10,300 Lbs. 32" x 32" Thinwall K.O.'s
EXTENSION 2,100 Lbs.
Typ. 8 Places
TOP 5,000 Lbs.
17,400 Lbs. Total

Note: -No Scale-


All dimensions subject to allowable
1.) *10' Curb Inlet Top not available from Houston specification tolerances.
Plant.
TITLE PLANT STATE .
SECTION PAGE DATE

Grand Prairie
10' Curb Inlet - Dallas / Fort Worth Houston* TX 10.a.5 01-25-10
HEIDELBERGCEMENT Group
Precast Drainage Structures

4' - 2"

11' -4"

Frame and Cover as


2' - 1"
Required by City

#3 Rebar Left Exposed


for Gutter Tie-In

3' - 7"

20"

32" x 32" Thinwall


K.O.'s Front & Rear

5' - 8"
34" x 36" Thinwall
3"
K.O.'s Both Ends

8"

8"
Section View

Materials & Features


CONCRETE: 5,000 PSI

REINFORCING: GRADE 60

H-20 LOADING

MAXIMUM PIPE SIZE: 24" I.D.


-No Scale-
WEIGHT: .............. 16,000 Lbs. Total All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

10' Curb Inlet w/5.0' Invert


Alvarado TX 10.a.6 01-25-10
Dallas / Fort Worth HEIDELBERGCEMENT Group
Precast Drainage Structures

4' - 0"

16' - 0"

Frame and Cover as


Required by City

1' - 10"

#3 Rebar Left
Exposed for
Gutter Tie-In

32" x 32"
Thinwall K.O.'s 3' - 10 1/2"
Typ. 10 Places

17"

5'-8 1/2"

Materials & Features


CONCRETE: 5,000 PSI 6"

6"
REINFORCING: per ASTM A-615 or A-185
Section View
MAXIMUM PIPE SIZE: 24" I.D.

WEIGHT:
BASE - 14,300 Lbs.
-No Scale-
TOP - 8,600 Lbs. All dimensions subject to allowable
22,900 Lbs. Total specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

15' Curb Inlet - Dallas / Fort Worth Grand Prairie TX 10.a.7 01-25-10
HEIDELBERGCEMENT Group
Precast Drainage Structures

4' - 2"

16' -4"

Frame and Cover as


Required by City
10"

4' - 8"

20"

Holes For Rebar Dowels


5' - 6" For Connection to
3" Paving.
Thinwall K.O.'s
Both Ends
51" x 38" Thinwall
8"
K.O.'s Front & Rear
8"
Section View

Materials & Features


CONCRETE: 5,000 PSI

REINFORCING: GRADE 60

H-20 LOADING

-No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

15' Curb Inlet w/5.0' Invert


Alvarado TX 10.a.8 01-25-10
Dallas / Fort Worth HEIDELBERGCEMENT Group
Precast Drainage Structures

4' - 0"
Frame and Cover as
Required by City

22' - 0"

1' - 10"

#3 Rebar Left
Exposed for
Gutter Tie-In

Connector Plate,
Front & Back 3' - 10 1/2"
with (2) 1" Bolts

32" x 32" Thinwall K.O.'s


Typ. 16 Places

17"

Materials & Features


5' - 8 1/2"
CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185

MAXIMUM PIPE SIZE: 24" I.D. 6"

WEIGHT: 6"
BASE - 20,600 Lbs. Section View
TOP - 10,000 Lbs. -No Scale-
30,600 Lbs. Total All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

20' Curb Inlet - Dallas / Fort Worth Grand Prairie TX 10.a.9 01-25-10
HEIDELBERGCEMENT Group
Precast Drainage Structures
2 1/2" 18"
30"

(2) C.I. Grates


Weight - 180 Lb. Ea. 30"

4' - 0"
7' - 0"

10"
Inlet Top W/2 Frames
W/O Throat

4" I-beam

10"
6" x 60" opening
4' - 0"
7' - 0"
4' - 8 1/2"

6" 10"
6" Inlet Top W/2 Frames,
W/Throat
Section View
(W/Throat) 4" I-beam

Rebar (12" exposed)

Materials & Features


MAXIMUM PIPE SIZE: 24" I.D.
3' - 10 1/2"
CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185

CI CASTINGS: per ASTM A-46 Class 30/35

WEIGHT:
BASE - 7,000 Lbs.
32" x 32" Thinwall K.O.'s
TOP - 3,000 Lbs.
10,000 Lbs. Total Typ. 4 Places -No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

2-Grate Combination Inlet - 6' Grand Prairie TX 10.a.10 01-25-10


HEIDELBERGCEMENT Group
Precast Drainage Structures
(3) C.I. Grates 2 1/2" 18"
30"
Weight - 180 Lb. Ea.

30"

30"
4' - 0"

11' - 0"

Inlet Top W/3 Frames

10"

Rebar (12" exposed)


10"

4' - 0"
4" I-beam (Typ.)
4' - 8 1/2" 11' - 0"

6" x 90" opening

6"

6" Inlet Top W/3 Frames


Section View
4" I-beam (Typ.) 10"
(W/Throat)

Materials & Features


MAXIMUM PIPE SIZE: 24" I.D.
3' - 10 1/2"
CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185

CI CASTINGS: per ASTM A-46 Class 30/35


32" x 32" Thinwall K.O.'s
WEIGHT: Typ. 8 Places
BASE - 10,300 Lbs.
TOP - 5,600 Lbs. -No Scale-
15,900 Lbs. Total All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

3-Grate Inlet - 10' Grand Prairie TX 10.a.11 01-25-10


HEIDELBERGCEMENT Group
Precast Drainage Structures

18"
30"
2 1/2" 18"

30"
(4) C.I. Grates
Weight - 180 Lb. Ea.

4' - 0"
7' - 0"

10"
Inlet Top W/4 Frames

10"
4" I-beam

4' - 8 1/2"

6"

6"
3' - 10 1/2"
Section View

32" x 32" Thinwall K.O.'s


Typ. 4 Places
Materials & Features
MAXIMUM PIPE SIZE: 24" I.D

CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185.

CI CASTINGS: per ASTM A-46 Class 30/35

WEIGHT:
BASE - 10,300 Lbs.
-No Scale-
TOP - 3,000 Lbs.
All dimensions subject to allowable
13,300 Lbs. Total specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

4-Grate Inlet - 6' Grand Prairie TX 10.a.12 01-25-10


HEIDELBERGCEMENT Group
Precast Drainage Structures

18"
30"
2 1/2" 18"

30"
(6) C.I. Grates
Weight - 180 Lb. Ea.
30"

4' - 0"
4" I-beam (Typ.)

11' - 0"

Inlet Top W/6 Frames

10"

10"

4' - 8 1/2"

6"
6"

Section View 3' - 10 1/2"

32" x 32" Thinwall K.O.'s


Materials & Features Typ. 8 Places
MAXIMUM PIPE SIZE: 24" I.D.

CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185

CI CASTINGS: per ASTM A-46 Class 30/35

WEIGHT:
BASE - 10,300 Lbs.
TOP - 5,600 Lbs. -No Scale-
All dimensions subject to allowable
15,900 Lbs. Total
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

6-Grate Inlet - 10' Grand Prairie TX 10.a.13 01-25-10


HEIDELBERGCEMENT Group
Precast Drainage Structures

(5) C.I. Grates


12 3/4" W x 30" L x 1 1/2" D

22"

6"

30"

14"
18"
13' - 6" for 5 grates
30"
4"
6" 6"
Length as required
in 30" increments.
Tongue & Groove on
either end to make a
continuous trench.

Materials & Features


MAXIMUM PIPE SIZE: 10" PVC

CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185

CI CASTINGS: per ASTM A-46 Class 30/35

WEIGHT: 340 lbs./ft. -No Scale-


All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Grand Prairie
12" Trench Drain Houston TX 10.a.14 01-25-10
HEIDELBERGCEMENT Group
Precast Drainage Structures

(10) C.I. Grates


26" W x 24" L x 1 1/2" D

34"

5"

48"

36"
41"
21' - 0" for 10 grates
24"
48" I.D.
5"
5" 5"
Length as required
in 24" increments.
Tongue & Groove on
either end to make a
continuous trench.

Materials & Features


CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185

MAXIMUM PIPE SIZE: 18" RCP

CI CASTINGS: per ASTM A-46 Class 30/35

WEIGHT: 900 lbs./ft.


-No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Grand Prairie
24" Trench Drain Houston TX 10.a.15 01-25-10
HEIDELBERGCEMENT Group
Precast Drainage Structures

4' - 0" East Jordan #M-53


6' - 0"
18" Standard Ring
and Cover

11"

12"

8"

4' - 0" 3' - 0"


5' - 0" 6' - 0"

12", 18" & 24"

Rear KO: 51" W x 31" H

6"
3' - 0" 5' - 0" Keyway
6 3/4"

4' - 0" for 5' Depth


6" 3' - 0" for 4' Depth

2" x 5/8" Holes for Rebar to


be Furnished by Contractor.

6" Floor
9"
9"
Front KO: 50" W x 26" H
4' - 6"
Materials & Features 2' - 6"
CONCRETE: 5,000 PSI - 28 day strength
REINFORCING: (All reinforcing steel shall be grade 60.) 35" W x 31" H Thinwall
9" 9"
CAST IRON RING & COVER shall be in accordance with City of Austin K.O.'s Both Ends
Standard No. 503-1 & 503-2.
MASTIC SEALANT USED AS PRECAST. Construction joints shall meet the
requirements of City of Austin Standards specification item No. 510.2(C)4
joint material.
BOLT-TOGETHER UNITS for 15' inlets to be connected with 8" x 18" x 3/8" plates.
1/2" expanison anchors (4 per plate.)
Rebar for connection to paving shall be provided & installed by the contractor.
5/8" holes 2" deep will be provided by manufacturer. -No Scale-
The inlet as designed exceed the requirements of ASTM C478. All dimensions subject to allowable
RISERS AVAILABLE: 12", 18" & 24". specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

5' Curb Inlet 01-25-10


Waco TX 10.b.1
City of Austin HEIDELBERGCEMENT Group
Precast Drainage Structures

4' - 0"
Ring & Cover per
City Requirement
11' - 0"
11"

12"

8"
4' - 0" 3' - 0"
10' - 0"
11' - 0"

12", 18" & 24"

6" Keyway
3' - 0" Rear Knockouts:
6 3/4"
10' - 0" 34" High & 32"
Long Typical

2" x 5/8" Holes


for Rebar to be 4' - 0" for 5' Depth
Furnished by 3' - 0" for 4' Depth
Contractor.
6"
2' - 8"
Front Knockouts 6" Floor
32" W x 24" H 12"
2' - 8" 6"
Materials & Features
CONCRETE: 5,000 PSI - 28 day strength 12"
2' - 8"
REINFORCING: (All reinforcing steel shall be grade 60.) 32" W x 35" H Thinwall
CAST IRON RING & COVER shall be in accordance with City of Austin 6" K.O.'s Both Ends
Standard No. 503-1 & 503-2.
MASTIC SEALANT USED AS PRECAST. Construction joints shall meet the
requirements of City of Austin Standards specification item No. 510.2(C)4
joint material.
BOLT-TOGETHER UNITS for 15' inlets to be connected with 8" x 18" x 3/8" plates.
1/2" expanison anchors (4 per plate.)
Rebar for connection to paving shall be provided & installed by the contractor.
5/8" holes 2" deep will be provided by manufacturer. -No Scale-
The inlet as designed exceed the requirements of ASTM C478. All dimensions subject to allowable
RISERS AVAILABLE: 12", 18" & 24". specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

10' Curb Inlet Waco TX 10.b.2 01-25-10


City of Austin HEIDELBERGCEMENT Group
Precast Drainage Structures
Ring & Cover per
4' - 0" City Requirement

16' - 0"

12"

4' - 0" 3' - 0"

15' - 0"
16' - 0"

12", 18" & 24"


4' - 0"

3' - 6"
2" x 5/8" Holes for Rebar
to be Furnished by 3"
Contractor.

30" Diameter 6"


Thinwall Knockouts 30" W x 35" H Thinwall
Front & Rear K.O.'s Both Ends

Materials & Features


CONCRETE: 5,000 PSI - 28 day strength
REINFORCING: (All reinforcing steel shall be grade 60.)
CAST IRON RING & COVER shall be in accordance with City of Austin
Standard No. 503-1 & 503-2.
MASTIC SEALANT USED AS PRECAST. Construction joints shall meet the
requirements of City of Austin Standards specification item No. 510.2(C)4
joint material.
Rebar for connection to paving shall be provided & installed by the contractor.
5/8" holes 2" deep will be provided by manufacturer.
-No Scale-
The inlet as designed exceed the requirements of ASTM C478. All dimensions subject to allowable
RISERS AVAILABLE: 12", 18" & 24". specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

15' Curb Inlet w/ 4' - 0" Invert 10.b.3 01-25-10


Waco TX
City of Austin HEIDELBERGCEMENT Group
Precast Drainage Structures

Frame and Cover as


Required by City

3' - 10" 5' - 4"

12"
12"

6"
3' - 4 1/2"
3"

6"

8" 2' - 6" 8" 3' - 4 1/2"

6"

36" x 36" Thinwall K.O.'s


Front & Rear

32" x 36" Thinwall


Materials & Features K.O.'s both ends
CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185

MAXIMUM PIPE SIZE: 24" I.D.

WEIGHT:
BASE - 5,400 Lbs.
TOP - 2,400 Lbs. -No Scale-
7,800 Lbs. Total All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

5' Curb Inlet San Antonio 10.c.1 01-25-10


TX
City of San Antonio HEIDELBERGCEMENT Group
Precast Drainage Structures

Frame and Cover as


Required by City

4' - 2"

6' - 4"

10"

10"

4' - 2"
3"

6"

4' - 8"
6" 3' - 2" 6"

34" x 36" Thinwall K.O.'s


All Four Sides

Materials & Features


CONCRETE: 5,000 PSI

REINFORCING: GRADE 60

MAXIMUM PIPE SIZE: 24" I.D.


-No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

5' Curb Inlet w / 5.0' Invert


Alvarado TX 10.c.2 01-25-10
City of San Antonio HEIDELBERGCEMENT Group
Precast Drainage Structures

Frame and Cover as


Required by City
3' - 10"

11' - 4"

12"

6"

3' - 4 1/2"

6"
3 - 32" x 36" Thinwall
K.O.'s Front & Rear

32" x 36" Thinwall


K.O.'s both ends

12"

Materials & Features


CONCRETE: 5,000 PSI
3' - 4 1/2"
REINFORCING: per ASTM A-615 or A-185 3"

MAXIMUM PIPE SIZE: 24" I.D.

WEIGHT: 6"
BASE - 11,000 Lbs.
TOP - 5,000 Lbs. 8" 2' - 6" 8" -No Scale-
15,300 Lbs. Total All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

10' Curb Inlet


San Antonio TX 10.c.3 01-25-10
City of San Antonio HEIDELBERGCEMENT Group
Precast Drainage Structures

Frame and Cover as


3' - 10" Required by City

16' - 4"

12"
6"

3' - 4 1/2"

6"

3 - 50" x 36" Thinwall


K.O.'s Front & Rear

32" x 36" Thinwall


K.O.'s Both Ends
12"
Materials & Features
CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185 3' - 4 1/2"


3"
MAXIMUM PIPE SIZE: 24" I.D.

WEIGHT:
BASE - 14,300 Lbs. 6"
TOP - 8,600 Lbs. -No Scale-
22,900 Lbs. Total 8" 2' - 6" 8" All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

15' Curb Inlet


San Antonio TX 10.c.4 01-25-10
City of San Antonio HEIDELBERGCEMENT Group
Precast Drainage Structures

A A

Plan View

Dowels to be 3/4" x 6"


Bolts at each side
Mortar
(Typ.)
Cast Iron Grate and
Frame as Specified
Brick Adjustment

6" 2' - 6"

Varies
Mortar placed 3' - 0" Min.
by contractor
24" Max.

6"

Knockouts as Required

Section A-A
Materials & Features
CONCRETE: 5,000 PSI in 28 days.

REINFORCING STEEL: per ASTM A-615, Grade 60.

REINFORCING to meet AASHTO HS 20-44 Loading.

PRECAST STRUCTURE to meet ASTM C-857.

JOINT SEALANT: Ram-Nek gasket material. -No Scale-


All dimensions subject to allowable
FRAME AND GRATE/COVER as required. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Storm Sewer Type "A" Grate Inlet Houston TX 10.d.1 01-25-10


07-14-08
City of Houston HEIDELBERGCEMENT Group
Precast Drainage Structures
3' - 10"

Gutter Line or
Curb Low Point

3' - 10"
2' - 8"
A

Plan View

Curb

Cast Iron Grate and


Frame as Specified

Brick Adjustment

2' - 0" Min.


6" 2' - 6"

Varies
Mortar placed
by contractor
24" Max. RCP

Materials & Features


6"
CONCRETE: 5,000 PSI in 28 days.

REINFORCING STEEL: per ASTM A-615, Grade 60. Knockouts as Required


REINFORCING to meet AASHTO HS 20-44 Loading.

PRECAST STRUCTURE to meet ASTM C-857. Section A-A


JOINT SEALANT: Ram-Nek gasket material.

FRAME AND GRATE/COVER as required.

Note:
(a.) For driveway entrances only. Type "B" inlets
are not approved for new street applications.
-No Scale-
(b.) Base and walls to meet the size and requirements All dimensions subject to allowable
of Type "B" inlets. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Storm Sewer Type "B" Inlet w/ Grate Top TX


Houston 10.d.2 01-25-10
City of Houston HEIDELBERGCEMENT Group
Precast Drainage Structures
6' - 1 1/2"
1/
4" 3 1/4" 6 1/2" 6 1/2"

Standard Pavement
1 3/4"
1 3/4"

Expansion Joint
A
3 1/4" R

4"
4 1/2"

3"
1 3/4"
6"

7 3/4"
4 1/4"
6 1/2" 6 1/2"

1 1/2"
1'-0 1/4"

Curb

1 3/4"

2 1/2"
1 1/2"
3' - 6"

2'-6"
1'-5 3/4"

1' - 0 1/4" 6"


Plate
Frame 1' - 6 1/4"
6"

Transverse Section
Precast Curb Beam
Half Plan Half Section Plan
3' - 6"
3'-0 3/4" 3'-0 3/4"
6" 1' - 6" 1' - 6"

4"
5"

5"

5"
1" R
Gutter
4"
5"

3 3/4"
4"

2'-5" Min.
2'-0" Min.

6" 2'-6 3/4" 2'-6 3/4" 6"


2" +- Clr.

Varies (See Note "c")


Varies (See Note "c")

#6 with 3' - 4"


Standard "I" Beam (see
Hook Each Section Below)
End
Varies

2' - 6"
6"
(See Note 1)

1:2
2'-0"

1:2 Mortar
Mortar

9"
Fill Fill
6"

#4 @ 12 E W
#4 @ 12 E W
6"
B

Half Front Half Section___B


Section___ A Elevation
Acceptable
11" 11" 11"
Materials & Features Alternate Steel 3 3/4"
Bean Sizes:
CONCRETE: 5,000 PSI in 28 days. S6 x 17.5

4"
REINFORCING STEEL: per ASTM A-615, Grade 60. W6 x 16

3 3/4"
(Galvanized)
REINFORCING to meet AASHTO HS 20-44 Loading.

4"
#3 #4
PRECAST STRUCTURE to meet ASTM C-857. Section #4
3'-0 3/4"
JOINT SEALANT: Ram-Nek gasket material. Thru
Beam Half Front Elev.

Curb Beam Bar List


No. Size Length Shape Loc.
Note: 4 #4 5'-10" ST Hor.
(a.) Use std. cast iron frame & plates.
7 #4 0'-10' ST Vert.
(b.) Lead shall leave inlet at location and grade required.
7 #3 1'-6" BT
(c.) Dimension varies based on pipe diameter and wall thickness.
(d.) Center steel beam on inlet and cast walls as shown.
(e.) When top of curb to flowline is greater than 8' use type "C" inlet. -No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE SECTION PAGE . DATE

Storm Sewer Type "BB" Inlet Houston TX 10.d.3 01-25-10


City of Houston HEIDELBERGCEMENT Group
Precast Drainage Structures

6"

Frame and Cover as


A A Required by City
SEWER 4' - 0"
SEWER

Top
Section

6"

Plan
Center
2" R Section
T.O.C. Gutter Line

10"

Slope of Risers as
Pavement 6" 6" or 12" Required

Varies

6"
Bottom
Section
6" 3' - 0" 6"
4' - 0" Thinwall K.O.'s

Section A-A
Isometric View

Materials & Features


CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185

MAXIMUM PIPE SIZE: 24" I.D.

WEIGHT:
BASE - 3,605 Lbs.
TOP - 2,000 Lbs. -No Scale-
5,605 Lbs. Total All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "C" Curb Inlet - 3' x 3' Houston TX 10.d.4 01-25-10


City of Houston HEIDELBERGCEMENT Group
Precast Drainage Structures
SEWER

Frame and Cover as


Required by City
Curb Top
Type Weight 42"
Standard 1,420 Lbs. 72"
Right Ext. 1,400 Lbs. 10"
Left Ext. 1,400 Lbs.
R & L Ext. 1,380 Lbs.
Curb Top

PVC Pipe
Through
Extension w/Throat 42"
"D2" Weight
72"
12" 1,275 Lbs.
18" 1,910 Lbs. 30"
"D2"
60"
24" 2,550 Lbs.
30" 3,190 Lbs.

6"
Extension w/Throat

Bottom
42"
"Dl" Weight
72"
30" 4,525 Lbs.
36" 5,140 Lbs. 30"
60"
42" 5,820 Lbs.
48" 6,675 Lbs. Varies
54" 8,025 Lbs.
60" 7,665 Lbs.
66" 8,590 Lbs. 6"
"D1"
72" 8,900 Lbs.

Bottom
6"
Materials & Features. Thinwall K.O.'s
As Req'd
CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185


-No Scale-
H-20 LOADING All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "C" Curb Inlet - 30" x 60" Houston TX 10.d.5 01-25-10


HEIDELBERGCEMENT Group
Precast Drainage Structures
SEWER

C.I. Cover
Weight = 90 lbs.
(See Note 2) Frame and Cover as
Required by City

48"

72"
Curb Top with C.I. Ring 10"
Weight = 2,105 lbs.

PVC Pipe
Through
48"
Extension w/Throat
"C" Weight 72"
8" 800 Lbs. 36"
"C"
18" 2,000 Lbs. 60"
24" 2,700 Lbs.

6"

48"
72"

36"
Bottom 60"
Weight = 5,850 lbs.
78"

6"

70"
Materials & Features.
CONCRETE: 5,500 PSI at 28 days

REINFORCING: per ASTM A-615 Grade 60

H-20 LOADING 6"


Holes as Req'd.
C.I. CASTINGS: per ASTM A 48 Class 30/35
Note:
1.) Different height extension and bottoms
-No Scale-
are available on request. All dimensions subject to allowable
2.) Other castings are available. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "C" Curb Inlet - 36" x 60" Alvarado TX 10.d.6 01-25-10


HEIDELBERGCEMENT Group
Precast Drainage Structures

C.I. Cover
Weight = 90 lbs.
SEWER

Frame and Cover as


58"
(See Note 2) Required by City

48"
72"
Curb Top with C.I. Ring
Weight = lbs.
(Left Extension shown, 10"
Right Ext. also available

4"
Curb Top Extension 16" Bolt Pockets
Weight = lbs. 54" 6"
(Left Extension shown,
Right Ext. also available)
60"

13"

Extension w/Throat 48"


"C" Weight 72"
8" 800 Lbs. 36"
"C" 60"
18" 2,000 Lbs.
24" 2,700 Lbs.

6"

Bottom
Weight = 5,850 lbs.
48"
72"
36"
60"

Materials & Features. 78"


6"
CONCRETE: 5,500 PSI at 28 days

REINFORCING: per ASTM A-615 Grade 60 70"

H-20 LOADING

C.I. CASTINGS: per ASTM A 48 Class 30/35


6"
Note: Holes as Req'd.
1.) Different height extension and bottoms
-No Scale-
are available on request. All dimensions subject to allowable
2.) Other castings are available. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "C" Curb Inlet - 36" x 60"


Alvarado TX 10.d.7 01-25-10
With Left or Right Extension HEIDELBERGCEMENT Group
Precast Drainage Structures

C.I. Cover Frame and Cover as


SEWER

58"
Weight = 90 lbs. Required by City
(See Note 2) 48"
72"

Curb Top with C.I. Ring 10"


Weight = lbs.
(With Left & Right Extensions)
Bolt Pockets

4"
16"
54" 6"
Curb Top Extension
Weight = lbs.
60"
(With Left & Right Extensions)

13"

Extension w/Throat
"C" Weight
8" 800 Lbs. 48"
72"
18" 2,000 Lbs.
36"
24" 2,700 Lbs. "C" 60"

6"

Bottom
Weight = 5,850 lbs.
48"
72"
36"
60"
78"
Materials & Features.
6"
CONCRETE: 5,500 PSI at 28 days
70"
REINFORCING: per ASTM A-615 Grade 60

H-20 LOADING
6"
C.I. CASTINGS: per ASTM A 48 Class 30/35 Holes as Req'd.

Note:
1.) Different height extension and bottoms
-No Scale-
are available on request. All dimensions subject to allowable
2.) Other castings are available. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "C" Curb Inlet - 36" x 60"


Alvarado TX 10.d.8 01-25-10
With Left and Right Extensions HEIDELBERGCEMENT Group
Precast Drainage Structures

2"
60" or 66"

Body
Weight (60") = 3,500 lbs.
Weight (66") = 3,600 lbs.

28"

1" Coil Inserts

28"
Isometric View

1 1/4" Dia Holes 1" Coil Inserts 1" Coil Bolts

Profile Assembly Section

Materials & Features.


CONCRETE: 5,500 PSI at 28 days Plan
REINFORCING: per ASTM A-615 Grade 60

H-20 LOADING

C.I. CASTINGS: per ASTM A 48 Class 30/35


Note: -No Scale-
1.) Extensions can be made for All dimensions subject to allowable
right hand or left hand side. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "C" Wing Extension Alvarado TX 10.d.9 01-25-10


HEIDELBERGCEMENT Group
Precast Drainage Structures

Curb Top 18"


3' - 6"

9"
7"

Standard City of Houston Sto


rm
. Se
C.I. Frame & Grate we
r

Alternate Grate

3' - 6" 3' - 6"


Center Section
11"
2' - 6"

3' - 6" 3' - 6"


Riser Section
2' - 6" 2' - 6"
Varies

6"

3' - 6" 3' - 6"

Bottom Section 2' - 6" 2' - 6"

Varies
6"
Materials & Features. 2' - 6" to
5' - 0"
CONCRETE: 5,500 PSI at 28 days

REINFORCING: per ASTM A-615 Grade 60

H-20 LOADING
6"
C.I. CASTINGS: per ASTM A 48 Class 30/35
Note: Thinwall K.O.'s
1.) Different height extension and bottoms As Req'd
-No Scale-
are available on request. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE SECTION PAGE . DATE

Type "B" Curb Inlet Grand Prairie TX 10.d.10 01-25-10


City 0f Houston HEIDELBERGCEMENT Group
Precast Drainage Structures
18"

Curb Top 72"


Weight = 825 lbs.
10"

Adjusting Bolts (Typ.) 8"

V-4242-2 C.I.Cover
Weight = 110 lbs. (Each)
V-4242-2 C.I. Frame
Weight = 165 lbs. (Each)

42"
72"
Center Section
(Including "I" Beam) 13"
27"
Weight = 1,322 lbs.
27"

8" "I" Beam


Center Support
Grooves for
Extension Adjusting Bolts
(4) Typical
"C" Weight
8" 825 Lbs. 42" 72"
12" 1,250 Lbs.
18" 1,850 Lbs. 30" 60"
24" 2,475 Lbs. "C"
30" 3,100 Lbs.
6"

Bottom
Weight = ??? lbs. 42"
72"
30"
60"
Materials & Features. 78"
CONCRETE: 5,500 PSI at 28 days 6"
REINFORCING: per ASTM A-615 Grade 60 70"
H-20 LOADING

C.I. CASTINGS: per ASTM A 48 Class 30/35


Note: 6"
1.) Different height extension and bottoms
Thinwall K.O.'s
As Req'd -No Scale-
are available on request. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "BB" Inlet Alvarado TX 10.d.11 01-25-10


With Frame and Grate HEIDELBERGCEMENT Group
Precast Drainage Structures SEWER

Frame and Cover as


Curb Top Required by City
Type Weight 42"
72"
Standard 1,420 Lbs.
10"
Right Ext. 1,400 Lbs.
Left Ext. 1,400 Lbs.
R & L Ext. 1,380 Lbs. Curb Top

PVC Pipe
Through
42"
Extension w/Throat 72"
"D2" Weight 30"
"D2" 60"
12" 1,275 Lbs.
18" 1,910 Lbs.
24" 2,550 Lbs.
6"
30" 3,190 Lbs. Extension w/Throat

30" x 60" Hole w/Joint

72" 72"

6"

Roof Slab w/ 30" x 60"


Bottom Jointed Opening
"Dl" Weight Weight = 2,200 Lbs.
24" 5,785 Lbs. 72"
30" 6,580 Lbs. (Typ.)
36" 7,337 Lbs. 60"
(Typ.)
42" 8,175 Lbs.
48" 9,300 Lbs.
60" 10,950 Lbs.
Varies

"D1"
6"

Materials & Features. 6"


Bottom
CONCRETE: 5,000 PSI Thinwall K.O.'s
REINFORCING: per ASTM A-615 or A-185 As Req'd
-No Scale-
All dimensions subject to allowable
H-20 LOADING specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "C" Curb Inlet - 5' x 5' Houston TX 10.d.12 01-25-10


HEIDELBERGCEMENT Group
Precast Drainage Structures

5' - 0"

6"

Frame and Cover as


A A
Top
Section Required by City SEWER
4' - 0"

SEWER

6"

14' - 0"
13' - 0"
5' - 0"

Center
Section
2' - 0" 2' - 0"
Plan
Risers as
Required 2" R
T.O.C. Gutter Line

10"
Slope of
Pavement 6" 18"
Bottom
Section

Thinwall K.O.'s
Varies

Isometric View

6"

6" 3' - 0" 6"


4' - 0"
Materials & Features
Section A-A
CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185 -No Scale-
All dimensions subject to allowable
H-20 LOADING specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "C2" Curb Inlet Houston TX 10.d.13 01-25-10


City of Houston HEIDELBERGCEMENT Group
Precast Drainage Structures

6"

A A
SEWER

4' - 0"

Frame and Cover as


Required by City
6"

SEWER

14' - 0" Type "C-2A"

13' - 0" Type "C-2A"


Top

9' - 0" Type "C-1"

8' - 0" Type "C-1"


Section

Center
Section

Risers as 2' - 0" 2' - 0"


Wing Section
Required
on Right Side Plan
or Left Side

2" R
T.O.C. Gutter Line

10"

Slope of
Pavement 6" 18"

Bottom
Section
Thinwall K.O.'s
Varies

6"

6" 3' - 0" 6"


4' - 0"
Materials & Features Section A-A
CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185 -No Scale-
All dimensions subject to allowable
H-20 LOADING specification tolerances.

TITLE PLANT STATE SECTION PAGE . DATE

Type "C1" and "C2A" Curb Inlet Houston TX 10.d.14 01-25-10


City of Houston HEIDELBERGCEMENT Group
Precast Drainage Structures
3"R (Typ.)

6"

B
Dowels #4 x 12"

10' - 0" - Type C-2A


5' - 0" - Type C-1 4"
6" Dowels
3' - 0" Min.
#4 x 12" 6" 6"

A
6"

C C

3' - 0"
6"

6" 6" 6"


8"

Curb

6"
Curb

A
3/ " Expansion Joint

B
3/ " Expansion Joint 4
4

6"
Plain Redwood
Dowels #4 x 12"
(See Section B)
If Doweled Together
Match Line
Extension Inlet
Plan View
Nornal Gutter Line
4" Expansion Joint
Manhole 3/ Top Curb
Top Curb 3/ "
4 Expansion Joint Cover & Frame
Nornal Gutter Line
1' - 6"

1' - 8" - Type "C-1" 5' - 0"


5' - 0" 3' - 0" Min.
1' - 10" - Type "C-2A" 6" 6"

7' - 0" Max.


Bottom Curb

4' - 0" Min.


Match Line and Gutter
Bottom Curb Variable Pvmt.
and Gutter Lead
Pvmt. Depressed Pvmt. Surface

6"
10' - 0" - Type C-2A
5' - 0" - Type C-1

Elevation Section__ C
7" Manhole
3' - 0" #4 @ 12 E W #4 Bars Cover and Frame
See Section C-C
3/ " Expansion Joint
4
6" Nornal Gutter Line
Nornal Gutter Line 2" R

6"
10"

Nornal
6"
Ground 3/ "
Pvmt. 4 Exp. Joint
Varies With

6" Flare Outlet


*
Inlet Type

7' - 0" Max.


Pvmt. 5' - 0"

4' - 0" Min.


Variable
12"
6" 6"
6"

This Portion of the Mortar Placed


Wall Omitted When By Contractor
2' - 0" Built with Extension 6"
3' - 0"
#4 @ 12 E W

6"
Section__ A
Dowels #4 x 12" * -(See
Dowels #4 x 12"
Plan) #4 @ 6"
4' - 0" When Doweled
Materials & Features
CONCRETE: 5,000 PSI in 28 days. Section__ B
REINFORCING STEEL: per ASTM A-615, Grade 60.
Curb
REINFORCING to meet AASHTO HS 20-44 Loading.
PRECAST STRUCTURE to meet ASTM C-857.
JOINT SEALANT: Ram-Nek gasket material.

Note: 1" Redwood Board to a Depth Equal to the Pavement


Thickness - Fill with Approved Sealant.
(a.) Type "C-1": inlet with one extension. (5' - 0" long)
(b.) Type "C-2": inlet with one extension on each side.
Plan View - Curb Inlet
(c.) Type "C-2A": inlet with Double extension. (10' - 0" long)
(d.) For Type "C-2A" inlets provide a center 6" x 6" columns -No Scale-
All dimensions subject to allowable
in the curb line between all extensions.
specification tolerances.
TITLE PLANT STATE .
SECTION PAGE DATE

Storm Sewer Type "C-1", "C-2" & "C-2A" Inlets Houston TX 10.d.15 01-25-10
City of Houston HEIDELBERGCEMENT Group
Precast Drainage Structures

ale
Sw

A A

#5 @ 12 E W

Plan View

Cast Iron Grate and Frame


Finished Pavement See COH Standard Detail

1" Expansion Joint 1" Expansion Joint

36 3/8"
12" Min.

#5 @ 12 6"
Concrete Fill
Varies

by Contractor
12" Max.
(Typ.)

3" Clr. (Typ.)


Slope
6"

#5 @ 12 E W Min.

48 3/8"

Section A-A

Materials & Features


CONCRETE: 5,000 PSI in 28 days.

REINFORCING STEEL: per ASTM A-615, Grade 60.

REINFORCING to meet AASHTO HS 20-44 Loading.

PRECAST STRUCTURE to meet ASTM C-857.

JOINT SEALANT: Ram-Nek gasket material.

FRAME AND GRATE/COVER as required. -No Scale-


All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Storm Sewer Type "D" Inlet Houston TX 10.d.16 01-25-10


City of Houston HEIDELBERGCEMENT Group
Precast Drainage Structures

ale
Sw

A A

#4 @ 12 E W

Plan View

Cast Iron Grate and Frame


Finished Pavement See COH Standard Detail

1" Expansion Joint 1" Expansion Joint

28"
12" Min.

#4 @ 12 6"
Varies

12" Max.
3" Clr. (Typ.) (Typ.)
Slope
6"

#5 @ 12 E W Min.

40"

Section A-A

Materials & Features


CONCRETE: 5,000 PSI in 28 days.

REINFORCING STEEL: per ASTM A-615, Grade 60.

REINFORCING to meet AASHTO HS 20-44 Loading.

PRECAST STRUCTURE to meet ASTM C-857.

JOINT SEALANT: Ram-Nek gasket material.

FRAME AND GRATE/COVER as required.

Note:
(a.) Pipe entering inlet shall have a covering of not less -No Scale-
than 12" below paving base. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Storm Sewer Type "D-1" Inlet Houston TX 10.d.17 01-25-10


City of Houston HEIDELBERGCEMENT Group
Precast Drainage Structures

6"

Openings Optional All


Four Sides (Vertical
A A
Rebar Grate If Required)
SEWER
"L2"

Frame and Cover as


Required by City
6"

6" 6"
SEWER

"L1"
Plan Top
Section

10"

22"

Varies
Risers as
Required

Varies

6"

6" 6"
"L1"
Bottom
Section
Section A-A
"K.O."
(Typ.)

Isometric View
Materials & Features
CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185 Type "L1" "L2" "KO"

MAXIMUM PIPE SIZE: 24" I.D. E-3' 4' - 0" 4' - 0" 32"

WEIGHT: E-4' 5' - 0" 5' - 0" 48"


E-3' BASE - 3,600 Lbs. E-4' BASE - 5,223 Lbs.
E-3' TOP - 2,800 Lbs. E-4' TOP - 4,415 Lbs. -No Scale-
All dimensions subject to allowable
6,400 Lbs. Total 9,638 Lbs. Total
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "E" Curb Inlet Houston TX 10.d.18 01-25-10


City of Houston HEIDELBERGCEMENT Group
Precast Drainage Structures
B

#4 3' - 6" Long

4' - 4"
A A

#5 x 18" @ 6"

Mortar Placed
by Contractor 9"

B
4' - 4"

Section B-B Plan View

32" Standard Manhole


Frame and Cover - See
COH Standard Detail

6"
3"

12"
#5@ 12 E W

Varies

#5@ 12 E W
9"

Materials & Features


3" Clr.
CONCRETE: 5,000 PSI in 28 days.
6" 3' - 0" 6"
REINFORCING STEEL: per ASTM A-615, Grade 60.

REINFORCING to meet AASHTO HS 20-44 Loading. Section A-A


PRECAST STRUCTURE to meet ASTM C-857.

JOINT SEALANT: Ram-Nek gasket material.

FRAME AND GRATE/COVER as required.

Note:
(a.) Type "E" inlet top can be constructed on
a standard "C" manhole. -No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Storm Sewer Type "E" Inlet Houston TX 10.d.19 01-25-10


City of Houston HEIDELBERGCEMENT Group
Precast Drainage Structures
6' - 0"
6" 5' - 0" 6"

6"
3' - 6"

2' - 6"
6"

23 1/2" Cast Iron Ring


& Cover per C.O.H. A
Standard Detail

Plan View

#4 @ 12 E W Min.
Top of Curb 2' R
Gutter Line

Pvmt. Slope
6"

5' - 0"

3', 6', & 12'


Varies
Varies

Mortar Placed
by Contractor
9"
6"

#4 @ 12 E W Min.
Materials & Features 3" Min.
CONCRETE: 5,000 PSI in 28 days. Clear

REINFORCING STEEL: per ASTM A-615, Grade 60. 6" 2' - 6" 6"
3' - 6"
REINFORCING to meet AASHTO HS 20-44 Loading.

PRECAST STRUCTURE to meet ASTM C-857. Section A-A


JOINT SEALANT: Ram-Nek gasket material. -No Scale-
All dimensions subject to allowable
FRAME AND GRATE/COVER as required. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Storm Sewer Type "H-2" Inlet Houston TX 10.d.20 01-25-10


City of Houston HEIDELBERGCEMENT Group
Interceptors

3'
- 2"
"
-8
5'

7"
7"

18" Opening or
5' - 1"
Cast In Ring &
Cover
2' - 4"
1' - 11"

3'
" - 2"
-8
5'
6"
4" 5' - 0" 4"
5' - 8"

2" PVC Vent


Coupling

4' - 6"
4" PVC Coupling

4" PVC
Coupling

Materials & Features


CONCRETE: 5,000 PSI

REINFORCING: GRADE 60.

NECK EXTENSIONS AVAILABLE

INSIDE OF BOX COATED WITH 2 COATS OF


-No Scale-
COAL TAR EPOXY
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Acid Dilution Basin TX 11.1 01-25-10


HEIDELBERGCEMENT Group
Interceptors

Customer to Specify
Opening Size or
Cast-In Ring & Cover
5' - 0" 5' - 0"

6" 6"

18" 24"
2" Vent
4" Coupl.
(Typ - 2 places)

6"

Piping to be
furnished by 4' - 0" 5' - 0"
Contractor.

6"

6" 4' - 0" 6"

4' - 0" 2" Vent

4" Coupl.
(Typ - 2 places)
6"

Materials & Features


CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185

H-20 LOADING

SLAB TOP WEIGHT: 1,850 Lbs.

JUNCTION BOX WEIGHT: 6,000 Lbs. (4"-0" I.D.)

COAL TAR EPOXY COATING INSIDE


-No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

4' x 4' Acid Neutralization Tank - 350 Gallon TX 11.2 01-25-10


HEIDELBERGCEMENT Group
Interceptors

24"

4 1/2" 15" 4 1/2"

3"
14 1/2"

4"

4" or 6" PCV Outlet at Floor Level

4" or 6" PCV Inlet, 1" Above Floor

Tongue And Groove Joint


to Accept 15" RCP

Materials & Features


CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185

H-20 LOADING

WEIGHT = 350 Lbs. -No Scale-


All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Grand Prairie
15" Sample Well Houston TX 11.3 08-03-11
01-25-10
(Rev.) HEIDELBERGCEMENT Group
Interceptors

27" O.D.

4 1/2" 18" I.D. 4 1/2"

24"

4"

4" PCV Outlet at Floor Level

4" PCV Inlet, Above Floor

Materials & Features


CONCRETE: 5,000 PSI
REINFORCING: per ASTM-C-478-95
EXTENSIONS AVAILABLE:
18" X 4" Grade Rings
-No Scale-
Std. Cast Iron or H/D All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

27" x 24" Sample Well Waco TX 11.4 01-25-10


HEIDELBERGCEMENT Group
Interceptors

5' - 8"
4" 5' - 0" 4"

2" Vent

3' - 2"
SANITARY SEWER SANITARY SEWER

Opening or
Ring & Cover
per Job
Requirement

Plan View

2" H-10 Loading


4" H-20 Loading
Below Grade Lid
18"

* Available: Cast Flush & Top Mount

7"

2" Vent 3 1/2" Typ.


10"

4"
5' - 1"

4' - 6"
3' - 7"
3' - 8"

4"
12"

18"
6"

Section View

Materials & Features


CONCRETE: 5,000 PSI - 28 day strength.
PLUMBING: To be for 4" PVC, Sch. 40 at all pipe
connections in walls. (ASTM C-923)
2 - 103 STANDARD RING AND COVER - H10
OPTIONAL: 1600-1- H20
RATED GALLONS: 250.
APPROXIMATE WEIGHT: 6,500 lbs. w/Lid. -No Scale-
REINFORCING:Per ASTM A-615 or A-185. All dimensions subject to allowable
NECK EXTENSIONS AVAILABLE. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

250 Gallon Grease Interceptor Grand Prairie TX 11.5 01-25-10


HEIDELBERGCEMENT Group
Interceptors

6' - 0"

2" Vent

4" SANITARY SEWER SANITARY SEWER 4"

4' - 6"

18" Manhole Set 5" (Typ.)

Plan View

2" H-10 Loading


4" H-20 Loading
7"

18"
Below Grade Lid
* Available: Cast Flush & Top Mount

7"
1"
11"

2" Vent
2"

6' - 6"
4"
6' - 7"

5' - 0"
5' - 1"

4"
16"

12"
6"

Section View

Materials & Features


CONCRETE: 5,000 PSI - 28 day strength.
RATED GALLONS: 500
APPROXIMATE WEIGHT: 10,000 lbs. w / lid
PLUMBING: To be for 4" PVC, Sch. 40, watertight seal at
all pipe connections in walls. (ASTM C-923) -No Scale-
REINFORCING:Per ASTM A-615 or A-185. All dimensions subject to allowable
Top slab load rating = H-20. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Grand Prairie
500 Gallon Grease Interceptor Waco
TX 11.6 01-25-10
HEIDELBERGCEMENT Group
Interceptors

9' - 0"

2" Vent

4" SANITARY SEWER SANITARY SEWER 4"

5' - 0"

18" or 24" Manhole Set 6"


Plan View
2" H-10 Loading
4" H-20 Loading
5" H-20 Loading
7" 18"
Below Grade Lid
* Available: Cast Flush & Top Mount

7"

2" Vent
12"

4" 6' - 0"

6' - 7"

4' - 5"
5' - 0"
4"

18"
12"

6"
Section View

Materials & Features


CONCRETE: 5,000 PSI - 28 day strength.
RATED GALLONS: 1,000
APPROXIMATE WEIGHT: 18,000 lbs. w / lid
PLUMBING: To be for 4" PVC, Sch. 40. Watertight seal
at all pipe connections in walls. (ASTM C-923).
REINFORCING:Per ASTM A-615 or A-185. -No Scale-
TOP SLAB LOAD RATING = H-20. All dimensions subject to allowable
*AVAILABLE WITH 18" OR 24" OPENINGS IN TOP SLAB. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

1,000 Gallon Grease Interceptor Grand Prairie TX 11.7 01-25-10


HEIDELBERGCEMENT Group
Interceptors
13' - 0"

3" Vent

6"
6" SANITARY SEWER SANITARY SEWER

7' - 0"

24" Manhole Set 6" (Typ.)


Plan View

5" H-20 Loading


8"

24"
Below Grade Lid
* Available: Cast Flush & Top Mount

8"
10"

3" Vent
2"
6"
5' - 6"

4' - 10"
3' - 10"

6"
12"

16"
8"

Section View

Materials & Features


CONCRETE: 5,000 PSI - 28 day strength.
PLUMBING: To be for 6" PVC, Sch. 40 at all pipe
connections in walls. (ASTM C-923)
RATED GALLONS: 1,500
APPROXIMATE WEIGHT: 32,000 lbs. w / lid -No Scale-
REINFORCING:Per ASTM A-615 or A-185. All dimensions subject to allowable
TOP SLAB LOAD RATING = H-20. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Grand Prairie
1,500 Gallon Grease Interceptor Waco TX 11.8 01-25-10
HEIDELBERGCEMENT Group
Interceptors
13' - 0"

3" Vent

6"
6" SANITARY SEWER SANITARY SEWER

7' - 0"

24" Manhole Set 6" (Typ.)

Plan View
5" H-20 Loading
8"

24"
Below Grade Lid
* Available: Cast Flush & Top Mount

8"
3" Vent
10"

2"
6"
6' - 6"

5' - 10"
4' - 10"

6"
12"

16"
8"

Section View

Materials & Features


CONCRETE: 5,000 PSI - 28 day strength.
RATED GALLONS: 2,000
APPROXIMATE WEIGHT: 35,150 lbs. w / lid
PLUMBING: To be for 6" PVC, Sch. 40 watertight seal
at all pipe connections.
REINFORCING: 6 x 6 x W1.5 wire in all surfaces and bottom.
#3 bar continuous in all sides and bottom.
#4 bar continuous around openings.
#5 bar @ 8" O.C.E.A. way in top slab. -No Scale-
TOP SLAB LOAD RATING = H-20. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

2,000 Gallon Grease Interceptor Grand Prairie


TX 11.9 01-25-10
Waco HEIDELBERGCEMENT Group
Interceptors
13' - 0"

3" Vent

6"
6"

8' - 0"

24" Holes 6" (Typ.)

Plan View

5" H-20 Loading


Manhole Ring & Covers
7"

24"
3" Vent
10"

6"
6"
7' - 6"

6' - 11"
6' - 1"

6' - 0"

6"
12"

16"
7"

13' - 0"

Section View

Materials & Features


CONCRETE: 5,000 PSI - 28 day strength.
PLUMBING: To be for 6" PVC, Sch. 40 at all pipe connections
in walls. (ASTM C-923)
RATED GALLONS: 3,000
APPROXIMATE WEIGHT: 43,000 lbs.
REINFORCING:Per ASTM A-615 or A-185.
Contractor must wait 24 hours after setting/assembly products in
the field before water testing.
Hanson cannot be responsible for leaks when water level is more -No Scale-
than 1" above the top slab. All dimensions subject to allowable
Available: Below Grade Lid (shown) or Surface Grade Lid specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

3,000 Gallon Grease Interceptor Grand Prairie TX 11.10 01-25-10


HEIDELBERGCEMENT Group
Interceptors

13' - 0"

3" Vent

6"
6"

8' - 0"

24" Holes 6" (Typ.)

Plan View

5" H-20 Loading


Manhole Ring & Covers
7"

24"
3" Vent
10"

6"
6"
9' - 2"

8' - 8"
7' - 9"

7' - 1"
6"
12"

16"
7"

13' - 0"

Section View
Materials & Features
CONCRETE: 5,000 PSI - 28 day strength.
PLUMBING: To be for 6" PVC, Sch. 40 at all pipe connections
in walls. (ASTM C-923)
RATED GALLONS: 4,000
APPROXIMATE WEIGHT: 50,000 lbs.
REINFORCING:Per ASTM A-615 or A-185.
Contractor must wait 24 hours after setting/assembly products in
the field before water testing.
Hanson cannot be responsible for leaks when water level is more -No Scale-
than 1" above the top slab. All dimensions subject to allowable
Available: Below Grade Lid (shown) or Surface Grade Lid specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

4,000 Gallon Grease Interceptor Grand Prairie TX 11.11 01-25-10


HEIDELBERGCEMENT Group
Interceptors
13' - 0"

3" Vent

6"
6"

8' - 0"

24" Holes 6" (Typ.)

Plan View

5" H-20 Loading


Manhole Ring & Covers
7"

24"
3" Vent
10"

6"
6"
11' - 0"

10' - 5"
9' - 7"

9' - 6"
6"
12"

16"
7"

13' - 0"

Section View

Materials & Features


CONCRETE: 5,000 PSI - 28 day strength.
PLUMBING: To be for 6" PVC, Sch. 40 at all pipe
connections in walls. (ASTM C-923)
RATED GALLONS: 5,000
APPROXIMATE WEIGHT: 57,000 lbs.
REINFORCING: ASTM A-615 or A-185.
Contractor must wait 24 hours after setting/assembly products in
the field before water testing.
Hanson cannot be responsible for leaks when water level is more -No Scale-
than 1" above the top slab. All dimensions subject to allowable
Available: Below Grade Lid (shown) or Surface Grade Lid specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

5,000 Gallon Grease Interceptor Grand Prairie TX 11.12 01-25-10


HEIDELBERGCEMENT Group
Interceptors

3" Vent

3" Vent
8' - 2"

Outlet
Inlet
24" 24"

Front
19' - 0"

Plan View

5" H-20 Loading


Manhole Ring & Covers

3" Vent
9' - 0"

7' - 2"
7' - 5"

1' - 0"

19' - 0"

Section View

Materials & Features


CONCRETE: 5,000 PSI - 28 day strength.
PLUMBING: To be for 6" PVC, Sch. 40 at all pipe
connections in walls. (ASTM C-923)
STEEL REINFORCEMENT: ASTM A-615, Grade 60.
OTHER OPENINGS/RING & COVERS/NECK
EXTENSIONS available as required.
WEIGHT (EMPTY): 69,166 LBS.
GREASE CAPACITY: 13,500 lbs. -No Scale-
All dimensions subject to allowable
AVAILABLE: Below Grade Lid or Surface Grade Lid.
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

6,000 Gallon Grease Interceptor Grand Prairie TX 11.13 01-25-10


HEIDELBERGCEMENT Group
Interceptors

3" Vent

3" Vent
8' - 2"

Outlet
Inlet

24" 24"

Front
19' - 0"
Plan View

5" H-20 Loading


Manhole Ring & Covers

3" Vent
10' - 2"

8' - 2"
8' - 5"

1' - 0"

19' - 0"

Section View

Materials & Features


CONCRETE: 5,000 PSI - 28 day strength.
PLUMBING: To be for 6" PVC, Sch. 40 at all pipe
connections in walls. (ASTM C-923)
STEEL REINFORCEMENT: ASTM A-615, Grade 60.
OTHER OPENINGS/RING & COVERS/NECK
EXTENSIONS available as required.
GREASE CAPACITY: 15,750 lbs. -No Scale-
WEIGHT (EMPTY): 73,727 lbs. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

7,000 Gallon Grease Interceptor Grand Prairie TX 11.14 01-25-10


HEIDELBERGCEMENT Group
Interceptors

3" Vent

3" Vent
8' - 2"

Outlet
Inlet

24" 24"

Front
19' - 0"
Plan View

5" H-20 Loading


Manhole Ring & Covers

3" Vent
11' - 2"

9' - 3"
9' - 6"

1' - 0"

19' - 0"

Section View

Materials & Features


CONCRETE: 5,000 PSI - 28 day strength.
PLUMBING: To be for 6" PVC, Sch. 40 at all pipe
connections in walls. (ASTM C-923)
STEEL REINFORCEMENT: ASTM A-615, Grade 60.
OTHER OPENINGS/RING & COVERS/NECK
EXTENSIONS available as required.
GREASE CAPACITY: 18,000 lbs. -No Scale-
WEIGHT (EMPTY): 78,389 lbs. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

8,000 Gallon Grease Interceptor Grand Prairie TX 11.15 01-25-10


HEIDELBERGCEMENT Group
Interceptors

3" Vent

3" Vent
8' - 2"

Outlet
Inlet

24" 24"

Front
19' - 0"
Plan View

5" H-20 Loading


Manhole Ring & Covers

3" Vent
12' - 7"

10' - 5"
10' - 8"

1' - 0"

19' - 0"

Section View

Materials & Features


CONCRETE: 5,000 PSI - 28 day strength.
PLUMBING: To be for 6" PVC, Sch. 40 at all pipe
connections in walls. (ASTM C-923)
STEEL REINFORCEMENT: ASTM A-615, Grade 60.
OTHER OPENINGS/RING & COVERS/NECK
EXTENSIONS available as required.
GREASE CAPACITY: 20,250 lbs.
-No Scale-
WEIGHT (EMPTY): 84,546 lbs. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

9,000 Gallon Grease Interceptor Grand Prairie TX 11.16 01-25-10


HEIDELBERGCEMENT Group
Interceptors

3" Vent
8' - 2"

3" Vent

Outlet
Inlet

24" 24"

Front
19' - 0"
Plan View

5" H-20 Loading


Manhole Ring & Covers

3" Vent
14' - 0"

11' - 9"
12' - 0"

1' - 0"

19' - 0"

Section View

Materials & Features


CONCRETE: 5,000 PSI - 28 day strength.
PLUMBING: To be for 6" PVC, Sch. 40 at all pipe
connections in walls. (ASTM C-923)
STEEL REINFORCEMENT: ASTM A-615, Grade 60.
OTHER OPENINGS/RING & COVERS/NECK
EXTENSIONS available as required. -No Scale-
GREASE CAPACITY: 22,500 lbs. All dimensions subject to allowable
WEIGHT (EMPTY): 90,055 lbs. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

10,000 Gallon Grease Interceptor Grand Prairie TX 11.17 01-25-10


HEIDELBERGCEMENT Group
Interceptors
5' - 7"
3"
34" 23"

5 1/2"

2" Vent

SANITARY SEWER SANITARY SEWER 5' - 7"

18" Manhole Set

3"

Plan View

Below Grade Lid


6 1/2" 4"

* Available: Cast In Flush & Top Mounts 18"


Surface Grade Lid
6 1/2"

C.O. C.O.
5" 2" Vent 2" Vent Holes

Inlet Liquid Level 51 1/2"


Out
ug. Depth

12" 45"
Varies

40" Outlet
PVC
15" Baffle 12"

3" 3"
5' - 6"

Section View

Materials & Features


CONCRETE: 5,000 PSI - 28 day strength.
PLUMBING: Cast-n-seal inserts to accommodate 4" PVC, Sch. 40.
at all pipe connections in walls. (ASTM C-923)
RATED GALLONS: 500
REINFORCING:Per ASTM A-615 or A-185.
Top slab load rating = H-20.
Contractor must wait 24 hours after setting/assembly.
Hanson cannot be responsible for leaks when water level is more -No Scale-
All dimensions subject to allowable
than 1" above the top slab. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

500 Gallon Grease Interceptor TX


Waco 11.18 01-25-10
Austin HEIDELBERGCEMENT Group
Interceptors
76" 43"
3"

5 1/2"

2" Vent

Inlet SANITARY SEWER SANITARY SEWER 5' - 7"

3"

24" Manhole Set

Plan View

5"
Below Grade Lid 6 1/2"

* Available: Cast In Flush & Top Mounts

Surface Grade Lid 6 1/2"


24"
C.O. C.O.
5" 2" Vent 2" Vent Holes
Liquid Level Varies
Inlet Out 51 1/2"
ug. Depth

12" 45"
Varies

40" Outlet
PVC
15" 15"
Baffle 12"

3 1/2" 3 1/2"
10' - 2"

Section View
Materials & Features
CONCRETE: 5,000 PSI - 28 day strength.
PLUMBING: Cast-n-seal inserts to accommodate 4" PVC, Sch. 40.
at all pipe connections in walls. (ASTM C-923)
RATED GALLONS: 1.000
REINFORCING:Per ASTM A-615 or A-185.
Top slab load rating = H-20.
Contractor must wait 24 hours after setting/assembly. -No Scale-
Hanson cannot be responsible for leaks when water level is more All dimensions subject to allowable
than 1" above the top slab. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

1,000 Gallon Grease Interceptor Waco TX 11.19 01-25-10


Austin HEIDELBERGCEMENT Group
Interceptors
75" 39"
3"

2" Vent

Inlet SANITARY SEWER SANITARY SEWER 5' - 8"

3 1/2"

24" Manhole Set

Plan View

5"
Below Grade Lid 6 1/2"

* Available: Cast In Flush & Top Mounts

Surface Grade Lid 6 1/2"


24"
C.O. 2" Vent C.O.
5" 3" 2" Vent Holes
Liquid Level Varies
Inlet Out 72 1/2"
24" 60% 40%
12" 66"
61" Outlet
PVC
15" 15"
Baffle 12"

3 1/2" 3"
9' - 8"

Section View
Materials & Features
CONCRETE: 5,000 PSI - 28 day strength.
PLUMBING: Cast-n-seal inserts to accommodate 4" PVC, Sch. 40.
at all pipe connections in walls. (ASTM C-923)
RATED GALLONS: 1.500
REINFORCING:Per ASTM A-615 or A-185.
Top slab load rating = H-20.
Contractor must wait 24 hours after setting/assembly. -No Scale-
Hanson cannot be responsible for leaks when water level is more All dimensions subject to allowable
than 1" above the top slab. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

1,500 Gallon Grease Interceptor TX


Waco 11.20 01-25-10
Austin HEIDELBERGCEMENT Group
Interceptors
13' - 0"

2" Vent

6" SANITARY SEWER 7' - 0"


SANITARY SEWER
6"

6"

24" Manhole Set

Plan View

2" H-10 Loading


5 1/2" H-20 Loading
Below Grade Lid 6 1/2"

* Available: Cast In Flush & Top Mounts

Surface Grade Lid


24" 6 1/2"

2" Vent
3"
Liquid Level 2" Outlet
Inlet
6' - 0"
24" 60% 40%

48" 45"
6"
PVC
15" 15"
Baffle 1' - 6"

6" 6"
13' - 0"

Section View
Materials & Features
CONCRETE: 5,000 PSI - 28 day strength.
PLUMBING: Cast-n-seal inserts to accommodate 6" PVC, Sch. 40.
at all pipe connections in walls. (ASTM C-923)
RATED GALLONS: 2,000
WEIGHT: 28,000 lbs. w/lid (Approx.)
REINFORCING:Per ASTM A-615 or A-185.
Top slab load rating = H-20.
Contractor must wait 24 hours after setting/assembly.
Hanson cannot be responsible for leaks when water level is more -No Scale-
than 1" above the top slab. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

2,000 Gallon Grease Interceptor Waco TX 11.21 01-25-10


Austin HEIDELBERGCEMENT Group
Interceptors
5' - 6"
3"
32" 24"

5 1/2"

2" Vent

SANITARY SEWER SANITARY SEWER 5' - 7"

18" Manhole Set

3 1/2"

Plan View

Below Grade Lid


6 1/2" 4"

* Available: Cast In Flush & Top Mounts 18"


Surface Grade Lid
6 1/2"

2" Vent 2" Vent Holes


Inlet
Liquid Level 51 1/2"

45"
40"
Outlet
18"
14"

4" 4"
5' - 6"

Section View

Materials & Features


CONCRETE: 5,000 PSI - 28 day strength.
PLUMBING: Cast-n-seal inserts to accommodate 4" PVC, Sch. 40.
at all pipe connections in walls. (ASTM C-923)
RATED GALLONS: 500
REINFORCING:Per ASTM A-615 or A-185.
Top slab load rating = H-20.
Contractor must wait 24 hours after setting/assembly.
Hanson cannot be responsible for leaks when water level is more -No Scale-
All dimensions subject to allowable
than 1" above the top slab. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

500 Gallon Grease Interceptor TX


Waco 11.22 01-25-10
Waco HEIDELBERGCEMENT Group
Interceptors
10' - 0"

5 1/2"

2" Vent

Inlet SANITARY SEWER SANITARY SEWER 5' - 6"

3 1/2"

24" Manhole Set

Plan View

5"
Below Grade Lid
6 1/2"

* Available: Cast In Flush & Top Mounts

Surface Grade Lid


24" 6 1/2"

2" Vent
5" Inlet 2" Vent Holes
Liquid Level Varies
51 1/2"
ug. Depth

45"
Varies

40" Outlet

18" 14"

3 1/2" 4"
10' - 0"

Section View
Materials & Features
CONCRETE: 5,000 PSI - 28 day strength.
PLUMBING: Cast-n-seal inserts to accommodate 4" PVC, Sch. 40.
at all pipe connections in walls. (ASTM C-923)
RATED GALLONS: 1,000
REINFORCING:Per ASTM A-615 or A-185.
Top slab load rating = H-20.
Contractor must wait 24 hours after setting/assembly. -No Scale-
Hanson cannot be responsible for leaks when water level is more All dimensions subject to allowable
than 1" above the top slab. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

1,000 Gallon Grease Interceptor Waco TX 11.23 01-25-10


Waco HEIDELBERGCEMENT Group
Interceptors
3"
6' - 3" 3' - 2"

2" Vent

Outlet
Inlet SANITARY SEWER SANITARY SEWER 5' - 8"

3"

24" Manhole Set

Plan View

5"
Below Grade Lid 6 1/2"

* Available: Cast In Flush & Top Mounts

Surface Grade Lid


24" 6 1/2"

2" Vent
6 1/2" 2" Vent Holes
Inlet Liquid Level Varies
74"
Liq. Depth
Varies

61"
Outlet

14"

3" 3"
9' - 8"

Section View 45 Bend to Sewer Main


Materials & Features This Elevation Determines
CONCRETE: 5,000 PSI - 28 day strength. Liquid Level in Tank.
PLUMBING: Cast-n-seal inserts to accommodate 4" PVC, Sch. 40.
at all pipe connections in walls. (ASTM C-923)
RATED GALLONS: 1,500
WEIGHT: 12,750 lbs. w/lid (Approx.)
REINFORCING:Per ASTM A-615 or A-185.
Top slab load rating = H-20.
Contractor must wait 24 hours after setting/assembly. -No Scale-
Hanson cannot be responsible for leaks when water level is more All dimensions subject to allowable
than 1" above the top slab. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

1,500 Gallon Grease Interceptor TX


Waco 11.24 01-25-10
Waco HEIDELBERGCEMENT Group
Interceptors

5' - 8"

4"

2" Vent

3' - 2"
VFG 20" x 20"
Frame & Grate
or Ring & Cover

Plan View

2" H-10 Loading


4" H-20 Loading

* Available: Cast In Flush & Top Mounts


Surface Grade Lid
7"
1' - 5"

10"

4" Pipe Connection


5' - 1"

Installed by Contr.

4"
3' - 8"

3 1/2"
Typ.
1' - 6"
6"

36" 24"

4" 5' - 0" 4"

5' - 8"

Materials & Features Section View


CONCRETE: 5,000 PSI - 28 day strength.
RATED GALLONS: 250.
APPROXIMATE WEIGHT w/LID: 6,500 lbs.
REINFORCING: GRADE 60.
NECK EXTENSIONS AVAILABLE. -No Scale-
ALSO AVAILABLE: All dimensions subject to allowable
VFG 20" X 20" FRAME & GRATE. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

250 Gallon Sand / Oil Interceptor Grand Prairie TX 11.25 01-25-10


HEIDELBERGCEMENT Group
Interceptors
6' - 0"
18" Ring & Cover

2" Vent

4' - 6"

4"
24" x 24" Frame & Grate
or 18" Dia. Ring & Cover

5"

4" 4"
Plan View

7"

* Available: Cast In Flush & Top Mounts

7" 18"

2" Vent
4" Inlet

4" 6' - 6"

4"
5' - 1" Outlet 4"

16"

6"
6' - 0"

Section View

Materials & Features


CONCRETE: 5,000 PSI - 28 day strength.
PLUMBING: To be for 4" PVC, Sch. 40. Watertight seal
at all pipe connections in walls. (ASTM C-923)
RATED GALLONS: 500
RATED FLOW: 60 - 80 GPM
APPROXIMATE WEIGHT: 10,000 lbs. w / Lid.
-No Scale-
REINFORCING:Per ASTM A-615 or A-185. All dimensions subject to allowable
Top slab load rating = H-20. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Grand Prairie
500 Gallon Sand / Oil Interceptor Waco
TX 11.26 01-25-10
HEIDELBERGCEMENT Group
Interceptors
9' - 0"
24" Ring & Cover

2" Vent

5' - 0"
4"
24" x 24"
Frame & Grate
or Ring & Cover

6"

4" 4"
Plan View 2" H-10 Loading
4" H-20 Loading
5" H-20 Loading
7"
Below Grade Lid
* Available: Cast In Flush & Top Mounts 18"
Surface Grade Lid

7"

18"

6' - 7"
4" 4"

6' - 0"
4" Outlet 4"
5' - 0"
18"

6"
9' - 0"

Section View

Materials & Features


CONCRETE: 5,000 PSI - 28 day strength.
PLUMBING: To be for 4" PVC, Sch. 40. Watertight seal
at all pipe connections in walls. (ASTM C-923)
RATED GALLONS: 1,150
RATED FLOW: 60 - 80 GPM
APPROXIMATE WEIGHT: 18,000 lbs. w / Lid.
REINFORCING:Per ASTM A-615 or A-185. -No Scale-
Top slab load rating = H-20. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

1,150 Gallon Sand / Oil Interceptor Grand Prairie TX 11.27 01-25-10


HEIDELBERGCEMENT Group
Interceptors
13' - 0"
24" Ring & Cover

3" Vent

7' - 0"

24" x 24" 6" PVC.


Frame & Grate
or Ring & Cover

6"

6" PVC. 6" PVC.


Plan View
5" H-20 Loading
8"
Below Grade Lid

* Available: Cast In Flush & Top Mounts 24"


Surface Grade Lid

8"

24"

5' - 6"
6" PVC.
6" PVC. Inlet
6" PVC.

Outlet 6" PVC.


3' - 10"
16"

8"
13' - 0"

Section View

Materials & Features


CONCRETE: 5,000 PSI - 28 day strength.
PLUMBING: To be for 6" PVC, Sch. 40. Watertight seal
at all pipe connections in walls. (ASTM C-923)
RATED GALLONS: 1,500
APPROXIMATE WEIGHT: 22,000 lbs. w / Lid.
REINFORCING:Per ASTM A-615 or A-185. -No Scale-
Top slab load rating = H-20. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

1,500 Gallon Sand / Oil Interceptor Grand Prairie TX 11.28 01-25-10


HEIDELBERGCEMENT Group
Interceptors
13' - 0"

3" Vent

6"
SANITARY SEWER SANITARY SEWER 6"

7' - 0"
24" x 24" Frame & Cover
or Ring & Cover

6" 6" 6" (Typ.)


24" Manhole Set
Plan View
5" H-20 Loading
8"

Below Grade Lid


* Available: Cast In Flush & Top Mounts

8"
24"
10"

3" Vent
2"
6"

6"

5' - 10"
6' - 6"

6"
4' - 10"

6"
14"
8"

Section View

Materials & Features


CONCRETE: 5,000 PSI - 28 day strength.
PLUMBING: To be for 6" PVC, Sch. 40. at all pipe
connections in walls. (ASTM C-923)
RATED GALLONS: 2,000
APPROXIMATE WEIGHT: 32,450 lbs. w / lid
REINFORCING: 6 x 6 x W1.5 wire in all surfaces and bottom.
#3 bar continuous in all sides and bottom.
#4 bar continuous around openings.
#5 bar @ 8" O.C.E.A. way in top slab. -No Scale-
Top slab load rating = H-20. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

2,000 Gallon Sand / Oil Interceptor Grand Prairie TX 11.29 01-25-10


HEIDELBERGCEMENT Group
Interceptors
13' - 0"

3" Vent

6"
6"

8' - 0"

6" 6" 6" (Typ.)

24" Holes
Plan View
24" x 24" Frame & Cover
or Ring & Cover
5" H-20 Loading
Manhole Ring & Covers
7"

24"
10"

3" Vent
6"
6"
6"
7' - 6"

6' - 11"
6"
6' - 1"

6"
16"
7"

13' - 0"

Section View
Materials & Features

CONCRETE: 5,000 PSI - 28 day strength.


PLUMBING: To be for 6" PVC, Sch. 40 at all pipe connections
in walls. (ASTM C-923)
RATED GALLONS: 3,000
APPROXIMATE WEIGHT: 43,000 lbs. Base Weight: 29,500 lbs.
REINFORCING:Per ASTM A-615 or A-185.
Contractor must wait 24 hours after setting/assembly products in
the field before water testing.
Hanson cannot be responsible for leaks when water level is more -No Scale-
than 1" above the top slab. All dimensions subject to allowable
Available: Below Grade Lid (shown) or Surface Grade Lid specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

3,000 Gallon Sand / Oil Interceptor Grand Prairie TX 11.30 01-25-10


HEIDELBERGCEMENT Group
Interceptors
13' - 0"

3" Vent

6" 6"

8' - 0"

6" 6" 6" (Typ.)


24" Holes

Plan View
24" x 24" Frame & Cover
or Ring & Cover
5" H-20 Loading
Manhole Ring & Covers
7"

24"
3" Vent
10"

6"
6"
6"
9' - 2"

8' - 8"
6"
7' - 9"

6"
16"
7"

13' - 0"

Section View
Materials & Features
CONCRETE: 5,000 PSI - 28 day strength.
PLUMBING: To be for 6" PVC, Sch. 40 at all pipe connections
in walls. (ASTM C-923)
RATED GALLONS: 4,000
APPROXIMATE WEIGHT: 50,000 lbs. Base Weight: 29,500 lbs.
REINFORCING:Per ASTM A-615 or A-185.
Contractor must wait 24 hours after setting/assembly products in
the field before water testing.
Hanson cannot be responsible for leaks when water level is more -No Scale-
than 1" above the top slab. All dimensions subject to allowable
Available: Below Grade Lid (shown) or Surface Grade Lid specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

4,000 Gallon Sand / Oil Interceptor Grand Prairie TX 11.31 01-25-10


HEIDELBERGCEMENT Group
Interceptors
13' - 0"

3" Vent

6" 6"

8' - 0"

6" 6" 6" (Typ.)

24" Holes

Plan View
24" x 24" Frame & Cover
or Ring & Cover
5" H-20 Loading
Manhole Ring & Covers
7"

24"
10"

3" Vent
6"
6"
11' - 0"

6"

10' - 5"
6"
9' - 7"

6"
16"
7"

13' - 0"

Section View

Materials & Features


CONCRETE: 5,000 PSI - 28 day strength.
PLUMBING: To be for 6" PVC, Sch. 40 at all pipe connections
in walls. (ASTM C-923)
RATED GALLONS: 5,000
APPROXIMATE WEIGHT: 57,000 lbs. Base Weight: 29,500 lbs.
REINFORCING:Per ASTM A-615 or A-185.
Contractor must wait 24 hours after setting/assembly products in
the field before water testing.
-No Scale-
Hanson cannot be responsible for leaks when water level is more
than 1" above the top slab. All dimensions subject to allowable
specification tolerances.
Available: Below Grade Lid (shown) or Surface Grade Lid
TITLE PLANT STATE .
SECTION PAGE DATE

5,000 Gallon Sand / Oil Interceptor Grand Prairie TX 11.32 01-25-10


HEIDELBERGCEMENT Group
Interceptors
5' - 6"
3"
32" 24"

5 1/2"

2" Vent

SANITARY SEWER SANITARY SEWER 5' - 6"

18" x 18" Frame


& Grate or Ring
& Cover

18" Manhole Set


3 1/2"

Plan View

Below Grade Lid


6 1/2" 2" H-10 Loading
4" H-20 Loading
* Available: Cast In Flush & Top Mounts 18"

Surface Grade Lid


6 1/2"

Inlet 2" Vent 2" Vent Holes

51 1/2"

External
Bypass 45"
40"
Outlet

14"

4" 4"
5' - 6"

Section View
Materials & Features
CONCRETE: 5,000 PSI - 28 day strength.
PLUMBING: Cast-n-seal inserts to accommodate 4" PVC, Sch. 40.
at all pipe connections in walls. (ASTM C-923)
RATED GALLONS: 500
REINFORCING:Per ASTM A-615 or A-185.
Top slab load rating = H-10 or H-20.
Contractor must wait 24 hours after setting/assembly. -No Scale-
Hanson cannot be responsible for leaks when water level is more All dimensions subject to allowable
than 1" above the top slab. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

500 Gallon Sand / Oil Interceptor Waco TX 11.33 01-25-10


Waco HEIDELBERGCEMENT Group
Interceptors
10' - 0"

5 1/2"
2" Vent

Inlet SANITARY SEWER SANITARY SEWER 5' - 6"

24" x 24" Frame & 3 1/2"


Grate or Ring &
Cover
24" Manhole Set

Plan View
5" H-20 Loading

Below Grade Lid 6 1/2"

* Available: Cast In Flush & Top Mounts

Surface Grade Lid


24" 6 1/2"

2" Vent
5" 2" Vent Holes
Inlet
51 1/2"

External
Bypass 45"
40"

Outlet 14"

3 1/2" 4"
10' - 0"

Section View
Materials & Features
CONCRETE: 5,000 PSI - 28 day strength.
PLUMBING: Cast-n-seal inserts to accommodate 4" PVC, Sch. 40.
at all pipe connections in walls. (ASTM C-923)
RATED GALLONS: 1,000
REINFORCING:Per ASTM A-615 or A-185.
Top slab load rating = H-20.
Contractor must wait 24 hours after setting/assembly. -No Scale-
Hanson cannot be responsible for leaks when water level is more All dimensions subject to allowable
than 1" above the top slab. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

1,000 Gallon Sand / Oil Interceptor TX


Waco 11.34 01-25-10
Waco HEIDELBERGCEMENT Group
Interceptors

5' - 8"

2" Vent

3' - 2"
2 - 18" Openings
or Cast-In Ring
& Covers
Plan View

2" H-10 Loading


4" H-20 Loading
7"

* Available: Cast In Flush & Top Mounts

2" Vent
PVC Cpl.

4"
5' - 1"

4"
3' - 8"

1' - 6"

5' - 8"

Section View

Materials & Features


CONCRETE: 5,000 PSI - 28 day strength.
RATED GALLONS: 250.
APPROXIMATE WEIGHT w/LID: 6,500 lbs.
REINFORCING: GRADE 60.
-No Scale-
4" NECK EXTENSIONS AVAILABLE. All dimensions subject to allowable
PLUMBING TO BE FOR 4" PVC, SCH 40 specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

250 Gallon Oil Interceptor Grand Prairie TX 11.35 01-25-10


HEIDELBERGCEMENT Group
Interceptors

6' - 0"

2" Vent

4' - 6"
4" 4"

2 -18" Openings
or Cast In Ring
& Cover 5"

Plan View

2" H-10 Loading


4" H-20 Loading
7"

* Available: Cast In Flush & Top Mounts

2" Vent
4"
6' - 7"

4" PVC. Coupling


5' - 1"

1' - 4"

6"
6' - 0"

Section View

Materials & Features


CONCRETE: 5,000 PSI - 28 day strength.
RATED GALLONS: 500.
APPROXIMATE WEIGHT w/LID: 10,000 lbs.
REINFORCING: GRADE 60.
4" NECK EXTENSIONS AVAILABLE. -No Scale-
PLUMBING TO BE FOR 4" PVC, SCH 40 All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

500 Gallon Oil Interceptor Grand Prairie TX 11.36 01-25-10


HEIDELBERGCEMENT Group
Interceptors

9' - 0"

2" Vent

4" SANITARY SEWER SANITARY SEWER 4"

5' - 0"

18" or 24" Manhole Set 6"


Plan View
2" H-10 Loading
4" H-20 Loading
5" H-20 Loading
7" 18"
Below Grade Lid
* Available: Cast Flush & Top Mount

7"

2" Vent
12"

4" 6' - 0"

6' - 7"

5' - 0"
4"

18"
12"

6"
Section View

Materials & Features


CONCRETE: 5,000 PSI - 28 day strength.
RATED GALLONS: 1,000
APPROXIMATE WEIGHT: 16,000 lbs. w / lid
PLUMBING: To be for 4" PVC, Sch. 40. Watertight seal
at all pipe connections in walls. (ASTM C-923).
REINFORCING:Per ASTM A-615 or A-185. -No Scale-
All dimensions subject to allowable
Top slab load rating = H-20.
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

1,000 Gallon Oil Interceptor Grand Prairie TX 11.37 01-25-10


HEIDELBERGCEMENT Group
Precast Vaults
4"

3'-10" 39"

4' - 6"
49"

4"
4" 5' - 4" 4"
6' - 0" 2-Ton Lifting Anchor
Top View Typ. 4 places

4' - 6"
5"
6' - 0"

Varies: Varies:
3', 4', 3', 4',
18" 5' & 6'
5' & 6'

11"
24"

5"

5"
4" 3' - 10" 4"

End View

7' - 0"
5' - 6"

Materials & Features


Thinwall K.O.
CONCRETE: 5,000 PSI
Typ. 2 places
REINFORCING: per ASTM A-615 or A-185.

VAULT WEIGHT: 3' ......... 5,000 Lbs. Isometric View


4' ......... 6,000 Lbs.
5' ......... 7,000 Lbs.
6' ......... 8,000 Lbs.

METAL DOORS OR CAST-IN RING AS SPECIFIED BY


CUSTOMER.

BOTTOM SLAB IS OPTIONAL.

-No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Dallas DC Meter Vault Grand Prairie TX 12.a.1 01-25-10


HEIDELBERGCEMENT Group
Precast Vaults

13"
10 1/2"
4"

4' - 6"
5'-2" 39"
49"

4"
4" 7' - 6" 4"
8' - 2"

Top View 2-Ton Lifting Anchor


Typ. 4 places
5' - 2"
5"
8' - 2"

Varies: Varies:
18" 4', 5' & 6' 4', 5' & 6'

15" 24"

5"
5"
4" 4' - 6" 4"

End View

9' - 0"
6' - 0"
Materials & Features
CONCRETE: 5,000 PSI Thinwall K.O.
Typ. 2 places
REINFORCING: per ASTM A-615 or A-185.

VAULT WEIGHT: 4' ......... 7,000 Lbs. Isometric View


5' ......... 8,300 Lbs.
6' ......... 9,600 Lbs.

METAL DOORS OR CAST-IN RING AS SPECIFIED BY


CUSTOMER.

BOTTOM SLAB IS OPTIONAL. -No Scale-


All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Dallas FM Meter Vault Grand Prairie TX 12.a.2 01-25-10


HEIDELBERGCEMENT Group
Precast Vaults

6"

4'-0"
5'-0" 39"
49"

6"
6" 8' - 0" 6"
9' - 0"

Top View

6" 5' - 0"


9' - 0"

Varies: Varies:
18" 4', 5' & 6' 4', 5' & 6'

9"
24"

6"
6"
6" 4' - 0" 6"

End View

10' - 0"
6' - 0"
Materials & Features
CONCRETE: 5,000 PSI Thinwall K.O.
Typ. 2 places
REINFORCING: per ASTM A-615 or A-185.

VAULT WEIGHT: 4' ........... 8,500 Lbs. Isometric View


5' ........... 9,750 Lbs.
6' ......... 11,000 Lbs.

METAL DOORS OR CAST-IN RING AS SPECIFIED BY


CUSTOMER.

BOTTOM SLAB IS OPTIONAL. -No Scale-


All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

4' x 8' Meter Vault Grand Prairie


Houston TX 12.a.3 01-25-10
HEIDELBERGCEMENT Group
Precast Vaults L

Flow

Plan View
Doors per City Specs.

OS&Y Gate Valve (Typ.)


U.L. Backflow
Preventer

Ductile Iron or
H
C-900 Stub-out

Flow

Adjustable Valve 12" Sump


Supports
Section View

Materials & Features


Basic Dimensions
CONCRETE: 5,000 PSI
Size W L H Weight
REINFORCING: per ASTM A-615 or A-185.
3" 5' - 0" 9' - 0" 5' - 6" 17,800 Lbs.
METAL DOORS AND LADDER AS SPECIFIED
BY CUSTOMER. 4" 5' - 0" 9' - 0" 5' - 6" 18,000 Lbs.

JOINTS SEALED WITH RAM-NEK. 6" 5' - 0" 9' - 0" 5' - 6" 18,000 Lbs.

8" 5' - 0" 9' - 0" 6' - 6" 21,000 Lbs.

10" 5' - 0" 9' - 0" 7' - 0" 22,000 Lbs.

-No Scale-
All dimensions subject to allowable
specification tolerances.
TITLE PLANT STATE .
SECTION PAGE DATE

3" thru 10"Double Detector Check Backflow Preventer Grand Prairie TX 12.a.4 01-25-10
In Precast Concrete Vault (w/ Slab Top) HEIDELBERGCEMENT Group
Precast Vaults
L

22"

Flow

FDC Galvanized All-Thread


W Retainer Rod (Typ.)
U.L. Check Valve
A A

FDC Riser
FLG x FPT Plan View
90 ELL

UL/FM Wafer Check Valve Fire Dept. Connection


(Optional)
Section A-A Doors per City Specs.
FDC Riser

OS&Y Gate Valve (Typ.)


U.L. Check Valve
U.L. Backflow
Preventers
Ductile Iron or
H C-900 Stub-out
Flow

6"

Adjustable Valve 12" Sump 6"


Supports
Section View
Materials & Features
Basic Dimensions
CONCRETE: 5,000 PSI
Size W L H Weight
REINFORCING: per ASTM A-615 or A-185.

METAL DOORS AND LADDER AS SPECIFIED 4" 5' - 0" 9' - 0" 5' - 6" 18,000 Lbs.
BY CUSTOMER.
6" 5' - 0" 9' - 0" 5' - 6" 18,000 Lbs.
JOINTS SEALED WITH RAM-NEK.
8" 5' - 0" 9' - 0" 6' - 6" 21,000 Lbs.
-No Scale-
All dimensions subject to allowable 10" 5' - 0" 9' - 0" 7' - 0" 22,000 Lbs.
specification tolerances.
TITLE PLANT STATE .
SECTION PAGE DATE

4" thru 10"Double Detector Backflow Preventer


Grand Prairie TX 12.a.5 01-25-10
In Precast Concrete Vault w/ FDC HEIDELBERGCEMENT Group
Precast Vaults
L

MJ x Flg.
Coupling
(Typ-2)
NRS Flg

Uniflange

Flg Ell
Flg. Tee
Gate Valve

(Typ-2)

(Typ-2)
(Typ-3)

W
Flow

Flg. Strainer
24" Compound Meter
Meter Test Tap

Plan View

Doors per City Specs.

Taper
Wall

H Flow

Adjustable Valve Ductile Iron


Supports (12" min.) (Typical)

12" Sump

Section View

Materials & Features


Basic Dimensions
CONCRETE: 5,000 PSI
Size By Pass L W H Weight
REINFORCING: per ASTM A-615 or A-185.
3" 3" 8' - 2" 5' - 2" 5' - 6" 14,000 Lbs.
METAL DOORS AND LADDER AS SPECIFIED
BY CUSTOMER. 4" 4" 9' - 0" 5' - 0" 5' - 6" 14,000 Lbs.

-No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

3" & 4" Compound Meter Vault Grand Prairie TX 12.a.6 01-25-10
HEIDELBERGCEMENT Group
Precast Vaults
L

MJ x Flg.
Coupling
(Typ-2)
NRS Flg

Uniflange

Flg Ell
Flg. Tee
Gate Valve

(Typ-2)

(Typ-2)
(Typ-3)

W
Flow

Flg. Strainer
24"
Compound Meter
w/Radio Read Meter Test Tap

Plan View

36" x 48" Alum. Hatchway


300 p.s.f. - Spring Assisted
(Centered on Meter)

12" Joints Sealed


Taper Watertight w/
Wall RamNek Gasket

H Flow

Adjustable Valve Ductile Iron


Supports (12" min.) (Typical)

8" Gravel Bed 12" Sump with Cast Iron Grate

Section View

Materials & Features Basic Dimensions


CONCRETE: 5,000 PSI Size By Pass L W H Weight

REINFORCING: per ASTM A-615 or A-185. 3" 3" 9' - 0" 5' - 0" 5' - 6" 19,750 lbs.
METAL DOORS AND LADDER AS SPECIFIED 4" 4" 9' - 0" 5' - 0" 5' - 6" 19,750 lbs.
BY CUSTOMER.
6" 6" 9' - 0" 5' - 0" 5' - 6" 19,750 lbs.
APPROVED GATE VALVES:
MUELLER, KENNEDY, CLOW,
WATEROUS, M & H. -No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

3", 4" & 6" Compound Meter Vault Grand Prairie TX 12.a.7 01-25-10
HEIDELBERGCEMENT Group
Precast Vaults
L

MJ x Flg.
Coupling
Uniflange
W (Typ-2)
Flow

Flg. Strainer
24"
Turbine Meter
w/Radio Read Meter Test Tap

Plan View

36" x 48" Alum. Hatchway


300 p.s.f. - Spring Assisted
(Centered on Meter)

12" Joints Sealed


Taper Watertight w/
Wall RamNek Gasket

H Flow

Adjustable Valve Ductile Iron


Supports (12" min.) (Typical)

8" Gravel Bed 12" Sump with Cast Iron Grate

Section View

Materials & Features Basic Dimensions


CONCRETE: 5,000 PSI Size By Pass L W H Weight

REINFORCING: per ASTM A-615 or A-185. 3" 3" 9' - 0" 5' - 0" 5' - 6" 19,750 lbs.
METAL DOORS AND LADDER AS SPECIFIED 4" 4" 9' - 0" 5' - 0" 5' - 6" 19,750 lbs.
BY CUSTOMER.
6" 6" 9' - 0" 5' - 0" 5' - 6" 19,750 lbs.
APPROVED GATE VALVES:
MUELLER, KENNEDY, CLOW,
WATEROUS, M & H. -No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

3", 4" & 6" Turbine Meter Vault Grand Prairie TX 12.a.8 01-25-10
HEIDELBERGCEMENT Group
Precast Vaults

w/Radio Read
Master Meter

Flg. Coupling
Flg. Strainer
Gate Valve

Gate Valve
Compound
Gate Valve

Dbl. Check
Gate Valve

Gate Valve
Uniflange

Flg x Flg

Flg x Flg
Flg. Tee

Flg x Flg

Flg x Flg

Flg. Tee

Flg x Flg
Flg. 90
Flg. 90

w/Spool
Galvanized All-Thread

Valve
Retainer Rod (Typ.)

Flow

Ductile Iron
12" x 12' X 3" Deep (Typical)
8" Remote Sump Pit w/ Grate

Plan View

36" x 48" Alum. Hatchway


300 p.s.f. - Spring Assisted
(Centered on Meter)

To Meter

24"

Adjustable Valve 8" Gravel Bed 12" Sump w/Grate


Supports (12" min.)
L

Section View
Materials & Features
Basic Dimensions
CONCRETE: 5,000 PSI
Size L W H Weight
REINFORCING: per ASTM A-615 or A-185.
3" 11' - 0" 6' - 0" 5' - 0" 28,000 lbs.
ALL VAULTS W/METER AND OR BACK FLOW PREVENTERS SHALL BE
PRECAST AND DELIVERED WITH ALL INTERNAL PIPING AND PARTS 4" 13' - 0" 7' - 0" 5' - 0" 30,000 lbs.
COMPLETE
6" 16' - 0" 8' - 6" 5' - 0" 42,000 lbs.
1/4" ALUMINUM DIAMOND PLATE COVER WITH EXTRUDED ALUMINUM
FRAME. HATCH TO BE FURNISHED WITH 316 STAINLESS STEEL SNAP
LOCK & STAINLESS HINGES TO BE CENTERED OVER METER.
-No Scale-
BACKFLOW ASSEMBLY SHALL BE FACTORY ASSEMBLED IN VAULT & All dimensions subject to allowable
HYDROSTATICALLY TESTED PRIOR TO DELIVERY. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

3" & Larger Domestic Meter Grand Prairie TX 12.a.9 01-25-10


and Double-Check Assembly HEIDELBERGCEMENT Group
Precast Vaults

w/Radio Read
Turbine Meter

Flg. Coupling
Flg. Strainer

Gate Valve
Gate Valve

Dbl. Check
Gate Valve
Uniflange

Flg x Flg
Flg x Flg

Flg x Flg
w/Spool

Valve
Galvanized All-Thread
Retainer Rod (Typ.)

Flow

Ductile Iron
12" x 12' X 3" Deep (Typical)
8" Remote Sump Pit w/ Grate

Plan View

36" x 48" Alum. Hatchway


300 p.s.f. - Spring Assisted
(Centered on Meter)

To Meter

24"

8" Gravel Bed 12" Sump w/Grate


Adjustable Valve
Supports (12" min.)
L

Section View
Materials & Features
Basic Dimensions
CONCRETE: 5,000 PSI
Size L W H Weight
REINFORCING: per ASTM A-615 or A-185.
3" 11' - 0" 6' - 0" 5' - 0" 28,000 lbs.
ALL VAULTS W/METER AND OR BACK FLOW PREVENTERS SHALL BE
PRECAST AND DELIVERED WITH ALL INTERNAL PIPING AND PARTS 4" 13' - 0" 7' - 0" 5' - 0" 30,000 lbs.
COMPLETE
6" 16' - 0" 8' - 6" 5' - 0" 42,000 lbs.
1/4" ALUMINUM DIAMOND PLATE COVER WITH EXTRUDED ALUMINUM
FRAME. HATCH TO BE FURNISHED WITH 316 STAINLESS STEEL SNAP
LOCK & STAINLESS HINGES TO BE CENTERED OVER METER.
-No Scale-
BACKFLOW ASSEMBLY SHALL BE FACTORY ASSEMBLED IN VAULT & All dimensions subject to allowable
HYDROSTATICALLY TESTED PRIOR TO DELIVERY. specification tolerances.

TITLE PLANT STATE SECTION PAGE . DATE

3" & Larger Turbine Meter Grand Prairie TX 12.a.10 01-25-10


and Double-Check Assembly HEIDELBERGCEMENT Group
Precast Vaults

Sump
16" 16"
Strainer
10" 10"
4' - 0"

Flow

Meter Test Tap Meter

By Pass Tap By Pass Hose


Furnished by City

8' - 0"

Plan View

3' x 3' Aluminum Door

Ground Level
3"
22"

9" 13 1/2" 29"


4' - 8"

Sump
12"

4"

Section View

Materials & Features


CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185.

METAL DOORS AND AS SPECIFIED BY CUSTOMER. -No Scale-


All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

4" Meter Vault Grand Prairie TX 12.a.11 01-25-10


HEIDELBERGCEMENT Group
Precast Vaults 24" x 32" Hinged Manway
L

Flow

W Galvanized All-Thread
Retainer Rod (Typ.)

Galv. Steel Skid-


Plan View Resistant Cover

24" x 32" Galv. Steel Door

OS&Y Gate Valve (Typ.)

U.L. Backflow
Preventer
Ductile Iron or
H
C-900 Stub-out
Flow

Adjustable Valve 12" Sump


Supports
Section View

Materials & Features


Basic Dimensions
CONCRETE: 5,000 PSI
Size W L H Weight
REINFORCING: per ASTM A-615 or A-185.
3" 3' - 6" 6' - 0" 4' - 0" 5,000 Lbs.
METAL DOORS AND LADDER AS SPECIFIED
BY CUSTOMER. 4" 3' - 6" 6' - 0" 4' - 0" 5,000 Lbs.

JOINTS SEALED WITH RAM-NEK. 6" 4' - 4" 7' - 10" 5' - 6" 11,000 Lbs.

8" 5' - 0" 8' - 8" 5' - 6" 16,000 Lbs.

10" 6' - 0" 9' - 0" 6' - 6" 17,000 Lbs


-No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

3" thru 10" Double Detector Check Backflow Preventer Houston TX 12.a.12 01-25-10
In Precast Concrete Vault (w/Metal Top) HEIDELBERGCEMENT Group
Precast Vaults 24" x 32" Hinged Manway
L

Flow

W Galvanized All-Thread
Retainer Rod (Typ.)

Galv. Steel Skid-


Plan View Resistant Cover

24" x 32" Galv. Steel Door

Uni-Flange
OS&Y Gate Valve (Typ.)

(Typ.)
U.L. Backflow
Preventer
Ductile Iron or
H
C-900 Stub-out
Flow

Adjustable Valve 12" Sump 2' - 0"


Supports
Section View

Basic Dimensions
Materials & Features
Size W L H Weight
CONCRETE: 5,000 PSI

3" 3' - 6" 6' - 0" 4' - 0" 5,000 Lbs.


REINFORCING: per ASTM A-615 or A-185.
3" 3' - 6" 6' - 0" 4' - 0" 5,000 Lbs.
METAL DOORS AND LADDER AS SPECIFIED
BY CUSTOMER. 6" 4' - 4" 7' - 10" 5' - 6" 11,000 Lbs.

8" 5' - 0" 8' - 8" 5' - 6" 16,000 Lbs.

10" 6' - 0" 9' - 0" 6' - 6" 17,000 Lbs


-No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

3" thru 10" Double Check Backflow Preventer Houston TX 12.a.13 01-25-10
In Precast Concrete Vault HEIDELBERGCEMENT Group
Precast Vaults L

22" PI

Flow

FDC Galvanized All-Thread


W Retainer Rod (Typ.)
U.L. Check Valve
A A w/ Ball Drip

FDC Riser Galv. Steel Skid-


24" x 32" Hinged Manway
FLG x FPT Resistant Cover
90 ELL Plan View
Adjustable Type Indicator Post

UL/FM Wafer Check Valve SHUT


Fire Dept. Connection
(Optional)
FDC Riser
Section A-A

Post Indicator Valve


OS&Y Gate Valve (Typ.)
Uni-Flange (Typ.)
U.L. Backflow
Preventers
Ductile Iron or
H C-900 Stub-out
Flow

6"

Adjustable Valve 12" Sump 6"


Supports
Section View
Materials & Features
Basic Dimensions
CONCRETE: 5,000 PSI
Size W L H Weight
REINFORCING: per ASTM A-615 or A-185.

METAL DOORS AND LADDER AS SPECIFIED 4" 4' - 4" 7' - 10" 5' - 6" 10,000 Lbs.
BY CUSTOMER.
6" 4' - 4" 7' - 10" 5' - 6" 12,000 Lbs.
JOINTS SEALED WITH RAM-NEK.
8" 5' - 0" 8' - 8" 5' - 6" 14,000 Lbs.
-No Scale-
All dimensions subject to allowable 10" 6' - 0" 9' - 0" 6' - 6" 18,000 Lbs.
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

4" thru 10" Double Check Backflow Preventer Houston TX 12.a.14 01-25-10
w/ PIV & FDC In Precast Concrete Vault HEIDELBERGCEMENT Group
Precast Vaults L

22" PI

Flow

FDC Galvanized All-Thread


3/ " Detector Meter w/ Retainer Rod (Typ.)
W 4
2 Shut-off Valves and
U.L. Check Valve
Backflow Preventer A A

FDC Riser Galv. Steel Skid-


24" x 32" Hinged Manway
FLG x FPT Resistant Cover
90 ELL Plan View
Adjustable Type Indicator Post

UL/FM Wafer Check Valve SHUT


Fire Dept. Connection
(Optional)
Section A-A
FDC Riser

Post Indicator Valve


OS&Y Gate Valve (Typ.)
Uni-Flange (Typ.)
U.L. Backflow
Preventers
Ductile Iron or
H C-900 Stub-out
Flow

Adjustable Valve Supports (Typ.)

6"
Gravel Bed (By Others)
12" Sump 6"
Section View
Materials & Features
Basic Dimensions
CONCRETE: 5,000 PSI
Size W L H Weight
REINFORCING: per ASTM A-615 or A-185.

METAL DOORS AND LADDER AS SPECIFIED 4" 4' - 4" 7' - 10" 5' - 6" 10,000 Lbs.
BY CUSTOMER.
6" 4' - 4" 7' - 10" 5' - 6" 12,000 Lbs.
JOINTS SEALED WITH RAM-NEK.
8" 5' - 0" 8' - 8" 5' - 6" 14,000 Lbs.
-No Scale-
10" 6' - 0" 9' - 0" 6' - 6" 18,000 Lbs.
All dimensions subject to allowable
specification tolerances.
TITLE PLANT STATE .
SECTION PAGE DATE

4" thru 10" Double Detector Check Backflow Houston TX 12.a.15 01-25-10
Preventer In Precast Concrete Vault w/ PIV & FDC HEIDELBERGCEMENT Group
Precast Vaults
L

MJ x Flg.
Coupling
(Typ-2)
NRS Flg

Uniflange

Flg Ell
Flg. Tee
Gate Valve

(Typ-2)

(Typ-2)
(Typ-3)

W
Flow

Flg. Strainer
24" Compound Meter
Meter Test Tap

Plan View

Doors per City Specs.

Taper
Wall

H Flow

Adjustable Valve Ductile Iron


Supports (12" min.) (Typical)

12" Sump

Section View

Materials & Features


Basic Dimensions
CONCRETE: 5,000 PSI
Size By Pass L W H Weight
REINFORCING: per ASTM A-615 or A-185.
8" 6" 13' 7' 5' - 4" 29,600 Lbs.
METAL DOORS AND LADDER AS SPECIFIED
BY CUSTOMER.

-No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

8" Compound Meter Vault Grand Prairie TX 12.a.16 01-25-10


HEIDELBERGCEMENT Group
Precast Vaults
Cover Lifting Device (Typ)

Galvanized Sleeve
Duo-Check Valve

Compound Meter
MJ x Flg Adapter

MJ x Flg Adapter

Linkseal Gasket
Spool Piece Flg

NRS Flg Valve


NRS Flg Valve
NRS Flg Valve

NRS Flg Valve

w/Waterstop &
Flg Strainer

for By-Pass
for By-Pass

Test Plug
Flg Tee

Flg Tee
W
18"

Flow Flow

Blind Flange Capped Blind Flange Capped


2' - 0"

With 2" Brass Plug With 2" Brass Plug

Plan View

Raised Plate Sectional Steel Ductile Iron or


Cover with 24" x 24" Hinged C-900 Stub-out
Manway. Hot-dipped Galvanized 1/4" x 6" Continuous
after Fabrication per City of Neoprene Gasket
Houston Specifications. Around Perimeter

H Flow Flow

2' - 0"
Adjustable Valve Supports

3"

6"
12" x 12" Sump with
6" Cast Iron Grate
L
Section View

Materials & Features


CONCRETE: 5,000 PSI Basic Dimensions
REINFORCING: per ASTM A-615 or A-185. Size By W L H Weight
METAL DOORS AND LADDER AS SPECIFIED Pass
BY CUSTOMER. 3" 2" 6' - 0" 11' - 6" 4' - 3" 14,500 Lbs.
4" 2" 6' - 0" 11' - 6" 4' - 3" 15,000 Lbs.
-No Scale-
All dimensions subject to allowable 6" 2" 6' - 0" 13' - 6" 4' - 3" 15,500 Lbs
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

City of Houston 3" thru 6" Domestic Water Houston TX 12.b.1 01-25-10
Compound Meter in Precast Concrete Vault HEIDELBERGCEMENT Group
Precast Vaults
L

Flg. Tee (Typ-2)

NRS Flg Gate

Water Meter
Flg Ell (Typ-2)

Valve (Typ-3)

Compound

Gate Valve
Uniflange

MJ x Flg.
NRS Flg.

Flg. Tee
Strainer

Adaptor
(Typ-2)

Flg. EL
By-Pass
W

Flow Flow
2' - 0"

Galv. Steel Skid- Test Plug Galvanized All-Thread


Resistant Cover Retainer Rod (Typ.)
Plan View

24" x 32" Galv. Steel Door

H
Flow Flow

Adjustable Valve

2' - 0"
Supports (12" min.) Ductile Iron
6" (Typical)

6" 12" Sump


Section View

Basic Dimensions
Materials & Features Size By Pass L W H Weight
CONCRETE: 5,000 PSI
3" 2" 8' - 8" 5' - 0" 4' - 0" 9,000 Lbs.
REINFORCING: per ASTM A-615 or A-185.
4" 2" 8' - 8" 5' - 0" 4' - 0" 9,000 Lbs.
METAL DOORS AND LADDER AS SPECIFIED 6" 3" 9' - 2" 5' - 8" 4' - 0" 12,000 Lbs.
BY CUSTOMER.
8" 4" 11' - 0" 6' - 0" 4' - 3" 18,000 Lbs.
-No Scale-
All dimensions subject to allowable
specification tolerances.
TITLE PLANT STATE SECTION PAGE . DATE

3" thru 8" Domestic Compound Water Meter Houston TX 12.b.2 01-25-10
In Precast Concrete Vault HEIDELBERGCEMENT Group
Precast Vaults
Cover Lifting Device (Typ)

MJ x Flg
Blind Flange Capped MJ x Flg
Adaptor
With 2" Brass Plug Adaptor
Flg Tee Flg Tee 18"

Flow Flow

W Galv. Sleeve
w/ Waterstop &
NRS Gate Valve Linkseal Gasket
NRS Gate Valve
for By-Pass Galv. Steel
Bronze By-Pass for By-Pass
Retainer Bracket
OS&Y Gate w/ Disv Meter, Gate OS&Y Gate
Valve Valves & Check Valve Valve Duo-Check
Valve

Plan View

Ductile Iron or C-900


Stub-out (Typ.)
Raised Plate Sectional Steel Cover with
24" x 24" Hinged Manway. Hot-dipped 1/4" x 6" Continuous
Galvanized after Fabrication per City of Neoprene Gasket
Houston Specifications. Around Perimeter

Combination Fire Service


& Water Meter Service Test Plug

H
Flow Flow

2' - 0"
Concrete or Galvanized
Angle Supports (Typ)
3"

6"
Gravel Bed 12" x 12" Sump with
6" (By Others) Cast Iron Grate
L
Section View

Basic Dimensions
Materials & Features Turbine Disc By W L H Weight
Meter Meter Pass
CONCRETE: 5,000 PSI Size Size
REINFORCING: per ASTM A-615 or A-185.
METAL DOORS AND LADDER AS SPECIFIED 4" 2" 2" 6' - 0" 11' - 6" 4' - 3" 14,500 Lbs.
BY CUSTOMER. 6" 4" 4" 6' - 0" 11' - 6" 4' - 3" 19,500 Lbs.

8" 4" 4" 8' - 0" 13' - 6" 4' - 3" 20,000 Lbs
-No Scale-
All dimensions subject to allowable 10" 6" 6" 8' - 6" 16' - 6" 4' - 6" 25,000 Lbs
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

City of Houston 4" thru 10" Combination 12.b.3 01-25-10


Houston TX
Fire and Domestic Meter HEIDELBERGCEMENT Group
Precast Vaults

MJ x Flg OS&Y Gate MJ x Flg


Adaptor Valves Adaptor 18"

Flow Flow

Bronze By-Pass w/Disc


Meter, Gate Valves
and Check Valve

Galv. Steel Skid-Resistant Cover Galvanized All-Thread


w/ 24" x 32" Hinged Manway Retainer Rod (Typ.)
Plan View

Combination Fire Service &


Water Meter Assembly
Test Plug
Ductile Iron or
C-900 Stub-out
H (Typical)

Flow Flow

2' - 0"
Concrete or Galvanized
Angle Supports (Typ)

6"
12" Sump
6"
L
Section View

Basic Dimensions
Materials & Features
Size By Pass L W H Weight
CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185. 4" 1" 11' - 6" 6' - 0" 4' - 3" 18,000 Lbs.

6" 1 1/2" 11' - 6" 6' - 0" 4' - 3" 18,000 Lbs.
METAL DOORS AND LADDER AS SPECIFIED
BY CUSTOMER. 8" 2" 13' - 0" 7' - 0" 4' - 6" 20,000 Lbs.

-No Scale- 10" 2" 13' - 0" 7' - 0" 4' - 6" 20,000 Lbs.
All dimensions subject to allowable
specification tolerances.
TITLE PLANT STATE .
SECTION PAGE DATE

4" thru 10" Combination Fire & Domestic Houston TX 12.b.4 01-25-10
Water Meter HEIDELBERGCEMENT Group
Precast Vaults Turbine or Compound
Meter By-Pass
6"
LR 90 ELL
Check Valve Flg (Typ-2)
Galvanized All-
Thread Retainer OS&Y Gate
OS&Y Gate Valve
Rod (Typ.) Valve
Ductile Iron Flg Tee Flg Tee
Mainline
Pipe Stub-out MJ x Flg Flg x MJ
W (Typ.)
Detector Meter
Adpt
Adpt

Flow Flow

6" Pipe Sleeve w/


18" (Min) 6" Waterproof
By Pass (Min) Resilient Gasket
(Typ) (Same Size as Mainline Meter)
OS&Y Gate 90 Flg
A Spool PC Flg x Flg Valve ELL (Typ-2) A
6"

Plan View
60" x 48" Double Leaf Aluminimun
Hatchway w/Snap-Lock Handle &
Locking Arm, Cast Flush w/ Concrete
Top or Riser (300 PSF or H20)
Grade
Concrete Extension
Risers as Required
Grade
6"
OSHA Approved
Steps @ 12" o.c.
All Joints made
Water-tight w/
Plastic Flexible
Gasket (Ram-Nek)

H
Flow Flow

Pipe Sleeve w/
12" Adjustable Valve Waterproof
Supports Resilient Gasket
6"
12" x 12" Sump with
6" Cast Iron Grate
L
Section A-A

Basic Dimensions
Mainline By W L H Weight
Materials & Features Meter Pass
CONCRETE: 5,000 PSI 3" 2" 5' - 8" 9' - 2" 7' - 0" 18,000 Lbs.
REINFORCING: per ASTM A-615 or A-185. 4" 2" 5' - 8" 9' - 2" 7' - 0" 19,000 Lbs.
METAL DOORS AND LADDER AS SPECIFIED 6" 2" 6' - 0" 11' - 0" 7' - 0" 24,000 Lbs
BY CUSTOMER.
6" 3" 6' - 0" 11' - 0" 7' - 0" 24,000 Lbs
8" 4" 6' - 0" 11' - 0" 7' - 0" 25,000 Lbs
-No Scale-
All dimensions subject to allowable 10" 6" 7' - 0" 13' - 0" 7' - 0" 31,000 Lbs
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

3" thru 10" Fireline Meter Assembly Houston TX 12.b.5 01-25-10


HEIDELBERGCEMENT Group
Precast Vaults

Duo Check Valve


Duo Check Valve

OS&Y Gate Valve


OS&Y Gate Valve

MJ x Flg Adaptor
MJ x Flg Adaptor

Service Strainer
Spool Piece Flg
Turbine Meter

U.L.F.M. Fire
Flg Tee

Flg Tee
W 18"

Flow Flow

A 90 ELL 90 ELL A
By-Pass
28"
NRS Gate Valve

Galv. Steel Skid-Resistant Galvanized All-


Cover & Frame w/ 24" x 32" Plan View Thread Retainer
Rod (Typ)
Hinged Manway

Grade
Ductile Iron or
C-900 Stub-out
(Typ.)

H Flow Flow

Concrete Pipe
Supports (Typ)

2' - 0"
3"

6"
12" x 12" Sump with
6" Cast Iron Grate

L
Section A-A

Basic Dimensions
Materials & Features Size By W L H Weight
Pass
CONCRETE: 5,000 PSI
3" 2" 6' - 0" 11' - 6" 4' - 3" 14,500 Lbs.
REINFORCING: per ASTM A-615 or A-185.
4" 2" 6' - 0" 11' - 6" 4' - 3" 15,000 Lbs.
METAL DOORS AND LADDER AS SPECIFIED
BY CUSTOMER. 6" 4" 7' - 0" 13' - 0" 4' - 6" 19,500 Lbs

8" 4" 7' - 0" 13' - 0" 4' - 6" 20,000 Lbs
-No Scale-
10" 4" 7' - 0" 13' - 0" 4' - 6" 25,000 Lbs
All dimensions subject to allowable
specification tolerances.
TITLE PLANT STATE .
SECTION PAGE DATE

3" thru 10" Fire Service Turbine Meter Houston TX 12.b.6 01-25-10
HEIDELBERGCEMENT Group
Precast Vaults

4"

4' - 0"

4' - 8"

4"
4" 4' - 0" 4"
4' - 8"

6"

6"

6" Lift Anchor


3' - 6" (Typ) 6"

Ring & Grate


per Customer
Specs.
12"
6"
7" 7" 6" K.O. 3' - 6"
10" 10" 10"
6" 6" (Typ. 8 places)
8" Sump
1" Hole for Ground Rod 6" x 20" K.O.
(4-each) (Typ. 8 places)
12"

Materials & Features


4' - 8"
CONCRETE: 5,000 PSI 4' - 8"

REINFORCING: per ASTM A-615 or A-185.

BASE WEIGHT: ..................... 1,905 Lbs.

MIDDLE WEIGHT: ..................... 2,830 Lbs.

SLAB TOP WEIGHT: ..................... 1,632 Lbs.

BUTYL GASKET FOR WATERTIGHT JOINTS


-No Scale-
CAST-IN RING AS SPECIFIED BY CUSTOMER. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

4' x 4' Fiber Optic Manhole Grand Prairie TX 12.b.7 01-25-10


HEIDELBERGCEMENT Group
Precast Vaults

Cast Iron Ring

Box Dimensions
C Dimension Large Small

A
A 24 1/2" 18"
B
B 26" 20"
Plan View
C 17 3/4" 11 1/2"

D 21" 16 1/2"

H 14 1/2" 11 1/2"

Thin-Walled Knock-outs
or Doghouses Provided
For Pipe Penetrations
H (Typical Both Sides.)

Section View

Materials & Features


CONCRETE: 5,000 PSI, 28 day strength.
REINFORCING: per ASTM A-615 or A-185.
-No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Meter Box - Residential Waco TX 12.c.1 01-25-10


HEIDELBERGCEMENT Group
Precast Vaults 2' - 6"

3' - 4"

Access Hatch: Plan View


Casting as Specified

2 1/2" x 2 1/2" x 1/4"


(Frame all Sides)

16"

4' - 0"
5' - 0"
6' - 0"

Thin-Walled Knock-outs
Varies
or Doghouses Provided
For Pipe Penetrations
(Typical Both Sides.)

* Gravel Bed
Section View Natural Ground

Materials & Features


CONCRETE: 5,000 PSI, 28 day strength.
REINFORCING: per ASTM A-615 or A-185.
Risers - ASTM C-478-1
DOOR: 30" x 40" spring assisted parkway traffic door shown.
Other access doors are available. -No Scale-
TYPICAL APPLICATION: Air release valve. All dimensions subject to allowable
* - Unit is also available with concrete bottom. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Meter Vault - Manhole Waco TX 12.c.2 01-25-10


HEIDELBERGCEMENT Group
Precast Vaults 5' - 6"

2' - 6"

2" PVC Drain

3' - 4" 5' - 6"

3 1/2"

Plan View
Access Hatch:
Casting as Specified

2 1/2" x 2 1/2" x 1/4"


(Frame all Sides)

6"

3 1/2"

18" x 24" Knock-Outs


Standard
3' - 9"

2" PVC Drain


4"

Section View Available with or without


Concrete Bottom
Materials & Features
CONCRETE: 5,000 PSI, 28 day strength.
REINFORCING: per ASTM A-615 or A-185.
DOOR: 30" x 40" spring assisted parkway traffic door shown.
Other access doors are available. -No Scale-
TYPICAL APPLICATION: City of Waco 2" meter. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

5' x 5' Meter Vault Waco TX 12.c.3 01-25-10


HEIDELBERGCEMENT Group
Precast Vaults

8' - 2" 2" (Typ.)

4" (Typ.)

5' - 2" 4' - 6"

4" (Typ.) 7' - 6"

Plan View

Hatch as Specified

6"

7' - 6"
18" x 24" Tall
Thin-Wall K.O.
Centered
(Typical Both 54"
Sides)

Bottom Slab (Optional) 6"


5' - 6" x 8' - 6" x 6" Thick

Section View

Materials & Features


CONCRETE: 5,000 PSI, 28 day strength.
REINFORCING: per ASTM A-615 or A-185. -No Scale-
DOOR IN TOP: Hatch as specified. All dimensions subject to allowable
TYPICAL APPLICATION: City of Waco Blackflow Preventer. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

7.5' x 4.5' Meter Vault Waco TX 12.c.4 01-25-10


HEIDELBERGCEMENT Group
Precast Vaults

13' - 0"
6" (Typ.)

7' - 0" 6' - 0"

6" (Typ.) 12' - 0"

Plan View

36" x 48" Aluminum Hatch


6"

12' - 0"
18" x 24" Tall
Thin-Wall K.O. 5' - 6"
Centered
(Typical Both Sides)

6"

Section View

Materials & Features


CONCRETE: 5,000 PSI, 28 day strength.
REINFORCING: per ASTM A-615 or A-185.
TYPICAL APPLICATIONS: 120" to 144" Meter
WEIGHT: 29,740 lbs. -No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

6' x 12' Meter Vault Waco TX 12.c.5 01-25-10


HEIDELBERGCEMENT Group
Precast Vaults

13' - 0"
6" (Typ.)

7' - 0" 6' - 0"

6" (Typ.) 12' - 0"

Plan View

30" x 30" Aluminum Hatch


8"

12' - 0"
18" x 24" Tall
Thin-Wall K.O. 5' - 4"
Centered
6' - 0"
(Typical Both Sides)

Section View

Materials & Features


CONCRETE: 5,000 PSI, 28 day strength.
REINFORCING: per ASTM A-615 or A-185.
TYPICAL APPLICATIONS: 120" to 144" Meter
COA - 10" BFP Vault
WEIGHT: Riser - 15,200 lbs.
Top Slab - 9,100 lbs. -No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

6' x 12' Meter Vault Waco TX 12.c.6 01-25-10


HEIDELBERGCEMENT Group
Precast Vaults
96"

6" (Typ.)

72" 60"

6" (Typ.) 84"

Plan View

30" x 30" H.D. Alum Access Hatch


as approved by the City (SPL # 614)

8 3/4"
Butyl Seal @ Joint

18" x 24" Tall


Thin-Wall K.O.
Centered
72"
(Typical Both Sides) 64"

18" Gravel Floor

Section View

Materials & Features


CONCRETE: 5,000 PSI, 28 day strength.
REINFORCING: per ASTM A-615 or A-185.
DOOR IN TOP: 30" x 30" heavy duty aluminum access hatch as
approved by the Cty of Austin (SPL#614)
TYPICAL APPLICATIONS: City of Austin compound meter
assembly - 3", 4" and 6". (SPL#298) -No Scale-
Top slab load rating = H-20. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

7' x 5' Meter Vault Waco TX 12.c.7 01-25-10


HEIDELBERGCEMENT Group
Precast Vaults
13' - 0"

6" (Typ.)

9' - 0" 8' - 0"

6" (Typ.) 12 - 0"

Plan View

City Valve & Customer Valve 48" x 72" Double Leaf Alum.
Cored & Set in Field by Access Hatch - H.D. as approved
Contractor after vault by the City (SPL # 614)
Installation.
8 3/4"

Butyl Seal @ Joint

18" x 24" Tall


Thin-Wall K.O.
Centered 72"
(Typical Both Sides) 64"

18"
Gravel Floor

Section View

Materials & Features


CONCRETE: 5,000 PSI, 28 day strength.
REINFORCING: per ASTM A-615 or A-185.
DOOR IN TOP: 48" x 72" aluminum access hatch. Exceeds ASTM C858.
TYPICAL APPLICATIONS: City of Austin 6" Fireline meter. (SPL#298) -No Scale-
Top slab load rating = H-20. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

8' x 12' Meter Vault Waco TX 12.c.8 01-25-10


HEIDELBERGCEMENT Group
Precast Vaults
13' - 0"
6" (Typ.)

11' - 0" 10' - 0"

6" (Typ.) 12 - 0"

Plan View
City Valve & Customer Valve 48" x 72" Double Leaf Alum.
Cored & Set in Field by Access Hatch - H.D. as approved
Contractor after vault by the City (SPL # 614)
Installation.
8 3/4"

Butyl Seal @ Joint

18" x 24" Tall


Thin-Wall K.O.
Centered 72"
(Typical Both Sides) 64"

18"
Gravel Floor

Section View

Materials & Features


CONCRETE: 5,000 PSI, 28 day strength.
REINFORCING: per ASTM A-615 or A-185.
DOOR IN TOP: 48" x 72" aluminum access hatch. Exceeds ASTM C858.
TYPICAL APPLICATIONS: City of Austin 8" Fireline meter. (SPL#298) -No Scale-
Top slab load rating = H-20. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

10' x 12' Meter Vault Waco TX 12.c.9 01-25-10


HEIDELBERGCEMENT Group
Precast Vaults
16' - 4"
8" (Typ.)

11' - 4" 10' - 0"

8" (Typ.) 15 - 0"

Plan View
City Valve & Customer Valve 48" x 72" Double Leaf Alum.
Cored & Set in Field by Access Hatch - H.D. as approved
Contractor after vault by the City (SPL # 614)
Installation.
8 3/4"

Butyl Seal @ Joint

18" x 24" Tall


Thin-Wall K.O.
Centered 72"
(Typical Both Sides) 64"

18"
Gravel Floor

Section View

Materials & Features


CONCRETE: 5,000 PSI, 28 day strength.
REINFORCING: per ASTM A-615 or A-185.
DOOR IN TOP: 48" x 72" aluminum access hatch. Exceeds ASTM C858.
TYPICAL APPLICATIONS: City of Austin 10" Fireline meter. (SPL#298) -No Scale-
Top slab load rating = H-20. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

10' x 15' Meter Vault Waco TX 12.c.10 01-25-10


HEIDELBERGCEMENT Group
Precast Vaults

Class "A" Concrete Min.


1" Hole

6"
2"

1"
W2 x W2.5 x 3 x 6
Wire Mesh Reinforcing

Top of Service Box & Lid Flush

Finished Grade

2 1/2"
24" Min.

18"

- Conduits as Required
*w/Bell-Ends, Grout 0 Ga. Wire Mesh
Openings.

- #6 Copper Wire for Tel.


*Co.,T.V. Co. & Elec. Co.
18" Concrete Pipe
4' - 0"

Ground. 3-Turns min.


ASTM C478 Min.
Around Pipe. Total Length
of Wire: Approx. 25'.

Section View

Materials & Features


CONCRETE: CLASS "A", 5,000 PSI.

SERVICE BOX WEIGHT: 672 LBS.


-No Scale-
LID WEIGHT: 60 LBS.
All dimensions subject to allowable
specification tolerances.
* - SUPPLIED BY OTHERS
TITLE PLANT STATE .
SECTION PAGE DATE

Service Box
Houston TX 12.c.11 01-25-10
City of Austin HEIDELBERGCEMENT Group
Precast Vaults

AU
ST
I

N,
TE
XAS
A
IC

-52
TR

M
EC
EL

30" Round Manhole Cover Marked "Austin, Finish Grade


Texas", "Electric" or equal. Adjust 30"
Manhole Rings to Finish Grade 1 - #4 Steel Rod,
Continuous
6"

From Cover
30" Min.
30" Min.
36" Inside Diameter Opening
Reinforced Concrete
4' - 6"

Pipe, Tongue and


36" I.D.
Groove Type
ASTM C478 Min.

* - Conduits as Required

6" Min.
w/Bell-Ends, Grout 44" O.D.
Openings.
Slope: 1/4"
per foot.
* - Ground for
Electric Dept.
4"
6"

* - Support Concrete Pipe


with 4 Bricks to Allow
Poured Concrete
* - 8"forI.D. Pipe in Center
Sump Hole
(By Others)to Flow
Under Pipe.
Section View

Materials & Features


CONCRETE: CLASS "A", 5,000 PSI.

36" PULLBOX WEIGHT: 2,360 LBS.

Note:
Slope all conduit entering pullboxes towards pullboxes.

Ground Pullbox.

For further requirements, coordinate with City of Austin Utilities Dept. -No Scale-
All dimensions subject to allowable
* - Supplied by others. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

36" Pullbox - Traffic Type Houston TX 12.c.12 01-25-10


City of Austin HEIDELBERGCEMENT Group
Precast Vaults
AU
ST
I 24" Round Manhole Cover

N,
TE
Marked "Austin, Texas

XAS
M-52A Electric or Equal.

A
IC

-52
TR

M
EC
EL

Concrete Lift-Out Ring


24" Round Manhole Cover Marked
"Austin", Texas", "M-52A Electric" Flush When in S.W.
Finish Grade or equal.
2"

36" I.D. Reinforced 24" Min.


Opening 2"
Concrete Pipe, Tongue
and Groove Type 36" I.D.

4' - 6"
ASTM C478 Min.
44" O.D.
6 Ga. Wire Mesh

Slope: 1/4" per foot.

3" Min.
Varies
* - Conduits as Required
w/Bell-Ends, Grout
Openings. 3" Min
- Grounding Rod
*
* - Support Concrete Pipe

4"
with 4 Bricks to Allow
Poured Concrete

6"
(By Others)to Flow
Under Pipe. 6"

* - 10" I.D. Pipe in


Center for Sump Hole

* - Pea Gravel
Section View

Materials & Features


CONCRETE: CLASS "A", 5,000 PSI.

36" PULLBOX WEIGHT: 2,360 LBS.

Note:
Metal ring & concrete ring pre-cast to fit groove dia. & both with 1/ "
2
clearance around edge of pullbox.
48" pullboxes shall be required whenever it is necessary to stack two

pullboxes.
Grounding - 30' of 2/0 stranded bare soft-drawn, tinned copper ground

or 5/8" x 6' - 0" copperweld ground rod. (See grounding detail.) -No Scale-
All dimensions subject to allowable
* - Supplied by others. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

36" Pullbox - Non Traffic Type


Houston TX 12.c.13 01-25-10
City of Austin HEIDELBERGCEMENT Group
Precast Vaults

AU
ST
I 30" Round Manhole Cover Marked

N,
"Austin, Texas", "M-55 Electric" or equal.

TE
XAS
IC
EC -55
TR
M
EL

Adjust 30" Manhole Ring


to Finish Grade

Finish Grade

1 - #4 Steel Rod,
Continuous
6"
8"

From Cover
30" Min.
30" Min.
48" Inside Diameter Opening
Reinforced Concrete
Pipe, Tongue and
48" I.D.
4' - 6"

Groove Type
ASTM C478 Min.

* - Conduits as Required
w/Bell-Ends, Grout

6" Min.
58" O.D.
Openings.
Slope: 1/4"
per foot. 6" 4"

* - Support Concrete Pipe


with 4 Bricks to Allow
Poured Concrete * - 2", 6" or 8" I.D. Pipe in
Center for Sump Hole
(By Others)to Flow
Under Pipe.

Section View

Materials & Features


CONCRETE: CLASS "A", 5,000 PSI.

48" PULLBOX WEIGHT: 4,915 LBS.

Note:
Slope all conduit entering pullboxes towards pullboxes.

Ground Pullbox.

For further requirements, coordinate with City of Austin Utilities Dept.


-No Scale-
* - Supplied by others. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

48" Pullbox - Traffic Type Houston TX 12.c.14 01-25-10


City of Austin HEIDELBERGCEMENT Group
Precast Vaults
AU
ST
I
24" Round Manhole Cover

N,
TE
Marked "Austin, Texas

XAS
M-52A Electric or Equal.

A
IC

-52
TR

M
EC
EL

Concrete Lift-Out Ring


24" Round Manhole Cover Marked
"Austin", Texas", "M-52A Electric" Flush When in S.W.
Finish Grade or equal.
2"

48" I.D. Reinforced 24" Min.


Opening 2"
Concrete Pipe, Tongue
and Groove Type 48" I.D.

4' - 6"
ASTM C478 Min.
58" O.D.
6 Ga. Wire Mesh
*T.V.- #6Co.Copper Wire for Tel. Co.,
& Elec. Co. Ground. 3-
Turns min. Around Pipe. Total
* - Conduits as Required

3" Min.
Length of Wire: Approx. 40'.
w/Bell-Ends, Grout
Openings.
Slope: 1/4" per foot.

* - Support Concrete Pipe

4"
with 4 Bricks to Allow
Poured Concrete

6"
(By Others)to Flow
Under Pipe. 6"

- 10" I.D. Pipe in


*Center for Sump Hole

* - Pea Gravel
Section View

Materials & Features


CONCRETE: CLASS "A", 5,000 PSI.

48" PULLBOX WEIGHT: 4,915 LBS.

Note:
Metal ring & concrete ring pre-cast to fit groove dia. & both with 1/ "
2
clearance around edge of pullbox.
48" pullboxes shall be required whenever it is necessary to stack two

pullboxes.
Grounding - 40' of 2/0 stranded bare soft-drawn, tinned copper ground.

(See grounding detail.)


-No Scale-
* - Supplied by others. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

48" Pullbox - Non Traffic Type Houston TX 12.c.15 01-25-10


City of Austin HEIDELBERGCEMENT Group
Septic Tanks
5' - 6"

Inlet 5' - 6"

Outlet

3"

Plan View

3 1/2"

14"
16"

48 1/2"
Inlet Liquid Level Outlet

6"

16" 37" Varies 45"


40"

3"

3"
Section View

Materials & Features


CONCRETE: 5,000 PSI
REINFORCING: 6 x 6 x W1.5 in all surfaces and cover.
#3 bar continuous from side walls to end.
(All bar Grade 60.)
INLET: Sanitary Tee - Sch. 40 stub
OUTLET: Regular Tee - Sdr. 35 stub
Watertight seal at all pipe connections.
-No Scale-
WEIGHT: 5,000 lbs. (approx.) w/Cover All dimensions subject to allowable
Cover weight = 1,135 lbs. (approx.) specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

500 Gallon Septic Tank Waco TX 13.1 01-25-10


HEIDELBERGCEMENT Group
Septic Tanks
8' - 0"

Inlet 5' - 6"

Outlet

3"

Plan View

3"

14"
3" 3" 16"

5"
Inlet
Liquid Level Outlet

6"
48 1/2"
14"

37" Varies
45"
40"

11"

3"

8' - 0"

Section View
Materials & Features
CONCRETE: 5,000 PSI
REINFORCING: 6 x 6 x W1.5 in all surfaces and cover.
#3 bar continuous from side walls to end.
(All bar Grade 60.)
INLET: Sanitary Tee - Sch. 40 stub
OUTLET: Regular Tee - Sdr. 35 stub
Watertight seal at all pipe connections. -No Scale-
WEIGHT: 7,600 lbs. (approx.) w/Cover All dimensions subject to allowable
Cover weight = 2,410 lbs. (approx.) specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

750 Gallon Septic Tank Waco TX 13.2 01-25-10


HEIDELBERGCEMENT Group
Septic Tanks
10' - 0"

Inlet 5' - 6"

Outlet

3"

Plan View

3 1/2"

14"
3" 3" 16"

5"
Inlet
Liquid Level Outlet

6"
48 1/2"
17"

37" Varies
45"
40"

20"

3"

10' - 0"

Section View
Materials & Features
CONCRETE: 5,000 PSI
REINFORCING: 6 x 6 x W1.5 in all surfaces and cover.
#3 bar continuous from side walls to end.
(All bar Grade 60.)
INLET: Sanitary Tee - Sch. 40 stub
OUTLET: Regular Tee - Sdr. 35 stub
Watertight seal at all pipe connections. -No Scale-
WEIGHT: 9,000 lbs. (approx.) w/Cover All dimensions subject to allowable
Cover weight = 2,410 lbs. (approx.) specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

1,000 Gallon Septic Tank Waco TX 13.3 01-25-10


HEIDELBERGCEMENT Group
Septic Tanks
10' - 11"

Inlet 6' - 2"

Outlet

3 1/2"
14"

Plan View

3 1/2"

14"
3 1/2" 3" 16"

5"
Inlet
Liquid Level Outlet

6"
51 1/2"
18"

40" Varies
48"
43"

21"

3"

10' - 11"

Section View
Materials & Features
CONCRETE: 5,000 PSI
REINFORCING: 6 x 6 x W1.5 in all surfaces and cover.
#3 bar continuous from side walls to end.
(All bar Grade 60.)
INLET: Sanitary Tee - Sch. 40 stub
OUTLET: Regular Tee - Sdr. 35 stub
Watertight seal at all pipe connections. -No Scale-
WEIGHT: 11,500 lbs. (approx.) w/Cover All dimensions subject to allowable
Cover weight = 2,950 lbs. (approx.) specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

1,250 Gallon Septic Tank Waco TX 13.4 01-25-10


HEIDELBERGCEMENT Group
Septic Tanks

6' - 3" 3" 3' - 2"

Inlet 5' - 8"

Outlet

3"

Plan View
8" 8"

3"
14"
3" 3" 16"

5 1/2" 8 1/2" 8 1/2"


Liquid Level
Inlet
Outlet
6"
5' - 9"
16"
16"

5' - 0 1/2" 4' - 9 1/2"

3"

9' - 8"

Materials & Features Section View


CONCRETE: 5,000 PSI
REINFORCING: 6 x 6 x W1.5 in all surfaces and cover.
#3 bar continuous from side walls to end.
(All bar Grade 60.)
INLET: Sanitary Tee - Sch. 40 stub
OUTLET: Regular Tee - Sdr. 35 stub
Watertight seal at all pipe connections. -No Scale-
WEIGHT: 12,000 lbs. (approx.) w/Cover All dimensions subject to allowable
Cover weight = 2,100 lbs. (approx.) specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

1,500 Gallon Septic Tank Waco TX 13.5 01-25-10


HEIDELBERGCEMENT Group
Septic Tanks 5' - 6"

18"

5' - 6"
Inlet
Outlet

3"

17 1/2" Riser - Roto Plan View


molded plastic High water alarm may be
w/concrete lid. installed on riser, or in
house (Garage) Optional
concrete lid w/ 4" PVC outlet
for electrical wiring purposes.

18"
16"

Outlet
3"
14"
8"

Inlet 6"

3' - 9"
3' - 1"

3"

Section View

Materials & Features


CONCRETE: 5,000 PSI
REINFORCING: 6 x 6 x W1.5 in all surfaces and cover.
#3 bar continuous from side walls to end.
#3 bar 8" O.C. in cover.
(All bar Grade 60.)
INLET: Sanitary Tee - Sch. 40 stub
Watertight seal at all pipe connections.
-No Scale-
WEIGHT: 5,000 lbs. (approx.) w/Cover All dimensions subject to allowable
Cover weight = 1,135 lbs. (approx.) specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

500 Gallon Pump Tank Waco TX 13.6 01-25-10


HEIDELBERGCEMENT Group
Septic Tanks
8' - 0"

5' - 6"
Inlet

3"

Plan View

18" Riser - Roto Molded


Plastic w/ Concrete Lid.

3 1/2" 3"

5"
Inlet Liquid Level

9"
48 1/2"

3" 45"

40"

18" x 24" Opening


18"

3"

8' - 0"

Materials & Features Section View


CONCRETE: 5,000 PSI
REINFORCING: 6 x 6 x W1.5 in all surfaces and cover.
#3 bar continuous in all sides.
#3 bar 8" O.C. in cover.
(All bar Grade 60.)
INLET: Sanitary Tee - Sch. 40 stub
Watertight seal at all pipe connections. -No Scale-
WEIGHT: 7,600 lbs. (approx.) w/Cover All dimensions subject to allowable
Cover weight = 2,410 lbs. (approx.) specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

750 Gallon Pump Tank Waco TX 13.7 01-25-10


HEIDELBERGCEMENT Group
Septic Tanks 10' - 0"

18"

Inlet 5' - 6"

3"

Plan View 17 1/2" Riser - Roto molded


plastic w/concrete lid.

18" 15 1/2"

3"
14"
8"
Inlet 3" Liquid Level

6"

45"

3' - 1" 3"

18" x 24" Opening


18"

3"

10' - 0"

Section View
Materials & Features
CONCRETE: 5,000 PSI
REINFORCING: 6 x 6 x W1.5 in all surfaces and cover.
#3 bar continuous in all sides.
#3 bar 8" O.C. in cover.
(All bar Grade 60.)
INLET: Sanitary Tee - Sch. 40 stub
Watertight seal at all pipe connections. -No Scale-
WEIGHT: 9,000 lbs. (approx.) w/Cover All dimensions subject to allowable
Cover weight = 2,410 lbs. (approx.) specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

1,000 Gallon Pump Tank Waco TX 13.8 01-25-10


HEIDELBERGCEMENT Group
Septic Tanks 10' - 11"

18"

Inlet 6' - 2"

3"

Plan View 15" Riser - Roto Molded


Plastic w/ Concrete Lid.

18" 15 1/2"

3 1/2"

14"
5"
Inlet 3" Liquid Level

6"
3"
4' - 0"

3' - 4"

24" x 24" Opening


24"

3"

10' - 11"

Section View
Materials & Features
CONCRETE: 5,000 PSI
REINFORCING: 6 x 6 x W1.5 in all surfaces and cover.
#3 bar continuous in all sides.
#3 bar 8" O.C. in cover.
(All bar Grade 60.)
INLET: Sanitary Tee - Sch. 40 stub
Watertight seal at all pipe connections. -No Scale-
All dimensions subject to allowable
WEIGHT: 11,500 lbs. (approx.) w/Cover
Cover weight = 2,950 lbs. (approx.) specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

1,250 Gallon Pump Tank Waco TX 13.9 01-25-10


HEIDELBERGCEMENT Group
Septic Tanks 9' - 8"

18"

Inlet 5' - 8"

3"

Plan View 15" Riser - Roto Molded


Plastic w/ Concrete Lid.

18" 15 1/2"

3 1/2"

14"
5"
Inlet 3" Liquid Level

6"
3"
5' - 6"

4' - 9"

24" x 24" Opening


24"

3"

9' - 8"

Section View
Materials & Features
CONCRETE: 5,000 PSI
REINFORCING: 6 x 6 x W1.5 in all surfaces and cover.
#3 bar continuous in all sides.
#3 bar 8" O.C. in cover.
(All bar Grade 60.)
INLET: Sanitary Tee - Sch. 40 stub
Watertight seal at all pipe connections. -No Scale-
All dimensions subject to allowable
WEIGHT: 12,000 lbs. (approx.) w/Cover
Cover weight = 2,100 lbs. (approx.) specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

1,500 Gallon Pump Tank Waco TX 13.10 01-25-10


HEIDELBERGCEMENT Group
Septic Tanks

9' - 3"
3"

5' - 11"

3" Plan View

3" 31 1/2" 42" 27" 3"


3" 3"
3"

5' - 9"

3"
9' - 3"

Section View

Materials & Features


CONCRETE: 5,000 PSI - 28 day strength
REINFORCING: (All bar Grade 60.)
XXX Gallons -No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

3-Chamber NORWECO System Waco TX 13.11 01-25-10


HEIDELBERGCEMENT Group
Septic Tanks

13' - 10"
3"

5' - 11"

3"
Plan View

3" 31 1/2" 42" 27" 55"


3" 3"
3"

5' - 9"

3"
13' - 10"

Section View

Materials & Features


CONCRETE: 5,000 PSI - 28 day strength -No Scale-
REINFORCING: (All bar Grade 60.) All dimensions subject to allowable
XXX Gallons specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

4-Chamber NORWECO System Waco TX 13.12 01-25-10


HEIDELBERGCEMENT Group
Septic Tanks

10' - 0"
3"

4' - 11"

3"
Plan View

3" 42" 53" 16" 3"


3" 3"
3"

31"

5' - 0"
9"

38"

29"

3"
8' - 2" 17"

Section View

Materials & Features


CONCRETE: 5,000 PSI - 28 day strength
REINFORCING: (All bar Grade 60.)
XXX Gallons -No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Jet Tank Waco TX 13.13 01-25-10


HEIDELBERGCEMENT Group
4"

300 Gallon
2' - 0"

Model # WTSP300
2" Drainage Plug Bottom Thickness = 4"
Weight = 3,250#

5' - 6" x 5' - 6" Outside Dimensions

4' - 10" O.D.

4' - 0" I.D. 5"

150 Gallon
2' - 0"

2" Drainage Plug

Model # WTR150
Bottom Thickness = 6"
Weight = 2,700#

Materials & Features


-No Scale-
CONCRETE: 5,000 PSI - 28 day strength
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

150 & 300 Gallon Water Troughs Waco TX 14.1 01-25-10


HEIDELBERGCEMENT Group
5' - 6" 4"
8' - 0"

500 Gallon

2' - 0"

Model # WTSP500
2" Drain Plug
Bottom Thickness = 4"
Weight = 3,400#

2' - 10"
4"
7' - 61/2"

300 Gallon

2' - 3 1/2"
Model # WTLB300
Bottom Thickness = 4"
Weight = 1,200# 2" Drain Plug
Lifting Hook
(Typ. 4 Places)

Materials & Features


CONCRETE: 5,000 PSI - 28 day strength -No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

300 & 500 Gallon Water Troughs Waco TX 14.2 01-25-10


HEIDELBERGCEMENT Group
7' - 6 1/2"

2' - 10"

A A
Typical Seep-Hole

Top View

2"

2' - 10"

2' - 3 1/2" 2' - 5 1/2"

Typical Hook

Section A-A End View

Materials & Features


CONCRETE: 5,000 PSI - 28 day strength
WEIGHT = 2,260 lbs. -No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Concrete Liner Box Waco TX 14.3 01-25-10


HEIDELBERGCEMENT Group
6' - 5 1/2"
2"

10"

5"

7' - 6"

Lid - Side View

3' - 3"

1' - 8"

Lid - Top View

7' - 6"
7' - 3"
A

B B
3' - 3"

A
Bottom - Top View
2' - 10"
2' - 7"

1 1/2" 1 1/2"
1' - 8"
1' - 10"

2"
Section A-A Section B-B

Materials & Features


-No Scale-
CONCRETE: 5,000 PSI - 28 day strength All dimensions subject to allowable
WEIGHT = 2,040 lbs. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Single Crypt Waco TX 14.4 01-25-10


HEIDELBERGCEMENT Group
Top View

4' - 0" 4' - 0" 5' 4'

12'

7' 6'

12' - 0"

16' - 0"

Side View

3"
4" 4 1/2"
1" Radius

12"

6" 2 1/2"

7' - 0"
5"

End View "Rib" Detail

Materials & Features


CONCRETE: 5,000 PSI - 28 day strength -No Scale-
All dimensions subject to allowable
WEIGHT = 1,800 lbs. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Concrete Cattleguard Waco TX 14.5 01-25-10


HEIDELBERGCEMENT Group
TXDOT Curb Inlets

WORKS
N IRON
DA

R
JO
SE
CA
T
DO
TX
MA
DE
IN US
. A

Exploded View
10' Curb Inlet (Right Extension)

22" E.J. 1814/1418


Ring & Cover

6"
Rear
DAN IRON WO
OR RK
EJ S
AS
C
Right
TXDOT
Varies

6"
Left

MADE
IN USA.
1'-0"

Materials & Features


CONCRETE: 5,000 PSI Front
6" 6"
6" 5' - 0" 5' - 0" 6"
REINFORCING: per ASTM A-615 or A-185
6"
H-20 LOADING
Plan View
10' Curb Inlet (Right Extension)
Note:
Curb Inlet & Extension Roof Slabs to be

poured as one piece. -No Scale-


Extension may also be located on left side. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "C" Curb Inlet w/Type "E" Extension Grand Prairie


Houston
TX 15.1 01-25-10
5', 10' &15' Options HEIDELBERGCEMENT Group
TXDOT Curb Inlets

IsometricView
10' Curb Inlet (Right Extension)

6"
Rear
Right
3'-0" to 5'-0"

6"
Left

1'-0"

6" Front 6"


6" 5' - 0" 5' - 0" 6"
Materials & Features 6"

CONCRETE: 5,000 PSI Plan View


10' Curb Inlet (Right Extension)
REINFORCING: per ASTM A-615 or A-185

H-20 LOADING

Note:
Extension may also be located on -No Scale-
left side. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "C" Curb Inlet w/Type "E" Extension, Grand Prairie


Houston
TX 15.2 01-25-10
Stage 1 5', 10' & 15' Options HEIDELBERGCEMENT Group
TXDOT Curb Inlets

Isometric View

6"
Rear

Right
Left
4'-0"

Front
6"
6" 10'-6" or 15' - 6" 6"

Plan View
Materials & Features
CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185 -No Scale-
H-20 LOADING All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "IR" Curb Inlet - Stage 1 Grand Prairie


Houston
TX 15.3 01-25-10
36" Pipe & Smaller HEIDELBERGCEMENT Group
TXDOT Curb Inlets

Isometric View

6"
Rear

Right
4'-0"

Left

Front
6"
6" 10'-6" or 15' - 6" 6"

Plan View
Materials & Features
CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185 -No Scale-
All dimensions subject to allowable
H-20 LOADING specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "IIR" Curb Inlet - Stage 1 Grand Prairie


Houston
TX 15.4 01-25-10
36" Pipe & Smaller HEIDELBERGCEMENT Group
TXDOT Curb Inlets

Isometric View

6"
Rear
5'-6" to 7' - 0"

Right
Left

Front
6"

6" 10'-6" or 15' - 6" 6"

Materials & Features Plan View


CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185 -No Scale-
All dimensions subject to allowable
H-20 LOADING specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "IR" Curb Inlet - Stage 1 Grand Prairie


Houston TX 15.5 01-25-10
42" - 60" Pipe HEIDELBERGCEMENT Group
TXDOT Curb Inlets

Isometric View

6"
Rear
5'-6" to 7' - 0"

Right
Left

Front
6"

6" 10'-6" or 15' - 6" 6"

Plan View
Materials & Features
CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185 -No Scale-
All dimensions subject to allowable
H-20 LOADING specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "IIR" Curb Inlet - Stage 1 Grand Prairie


Houston TX 15.6 01-25-10
42" - 60" Pipe HEIDELBERGCEMENT Group
TXDOT Curb Inlets

OT
TXD

Se
w
er
er
w
Se
TXD
OT

Isometric View

18" E.J. 1846-1


Ring & Cover
6"
Rear
TXDOT
5'-6" to 7' - 0"

Sewer

Sewer

Right
Left

TXDOT

Front
6"

6" 10'-6" or 15' - 6" 6"

Plan View

Materials & Features


CONCRETE: 5,000 PSI
-No Scale-
REINFORCING: per ASTM A-615 or A-185
All dimensions subject to allowable
H-20 LOADING specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Grand Prairie
Type "I" Curb Inlet Houston TX 15.7 01-25-10
HEIDELBERGCEMENT Group
TXDOT Curb Inlets

OT
TXD

Se
w
er
er
w
Se

TXD
OT

Isometric View

18" E.J. 1846-1


Ring & Cover
6"
Rear
TXDOT
5'-6" to 7' - 0"

Sewer

Sewer

Right
Left

TXDOT

Front
6"

6" 10'-6" or 15' - 6" 6"

Plan View
Materials & Features
CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185 -No Scale-
All dimensions subject to allowable
H-20 LOADING specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Grand Prairie
Type "II" Curb Inlet Houston TX 15.8 01-25-10
HEIDELBERGCEMENT Group
TXDOT Curb Inlets

Isometric View

6"
Rear
5'-6" to 7' - 0"

Right
Left

Front
6"
6" 10'-6" or 15' - 6" 6"

Plan View
Materials & Features
CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185 -No Scale-
All dimensions subject to allowable
H-20 LOADING specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Grand Prairie
Type "I" Curb Inlet - Stage 1 Houston TX 15.9 01-25-10
HEIDELBERGCEMENT Group
TXDOT Curb Inlets

Isometric View

6"
Rear
5'-6" to 7' - 0"

Right
Left

Front
6"
6" 10'-6" or 15' - 6" 6"

Plan View
Materials & Features
CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185 -No Scale-
All dimensions subject to allowable
H-20 LOADING specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Grand Prairie
Type "II" Curb Inlet - Stage 1 Houston
TX 15.10 01-25-10
HEIDELBERGCEMENT Group
TXDOT Curb Inlets

M
OR IN
STDRA

M
AD
US
IN E
A.

Isometric View

24" E.J. 1854-05


6" Bolt-Down Ring & Cover
Rear
Right

STORM
6"
DRAIN
3' - 8"

Left

1' - 10"
MADE
IN USA.

6" Front 6"

6" 10'-0" 5' - 0" 5' - 0" 6"

Plan View
20' Curb Inlet (Right Extension)

Materials & Features


CONCRETE: 5,000 PSI
-No Scale-
REINFORCING: per ASTM A-615 or A-185 All dimensions subject to allowable
H-20 LOADING specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "I" Curb Inlet w/Type "I-E Extension Grand Prairie


TX 15.11 01-25-10
Houston
San Antonio District HEIDELBERGCEMENT Group
TXDOT Curb Inlets

M
OR IN
STDRA
M
AD
E

IN
US
A.

Isometric View

24" E.J. 1854-05


6" Bolt-Down Ring & Cover
Rear
Right

STORM
6"
DRAIN
3' - 8"

Left

1' - 10"

MADE
IN USA.

6" Front 6"

6" 10'-0" 5' - 0" 5' - 0" 6"

Plan View
20' Curb Inlet (Right Extension)
Materials & Features
CONCRETE: 5,000 PSI
-No Scale-
REINFORCING: per ASTM A-615 or A-185
All dimensions subject to allowable
H-20 LOADING specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "II" Curb Inlet w/Type "II-E Extension Grand Prairie


TX 15.12 01-25-10
Houston
San Antonio District HEIDELBERGCEMENT Group
TXDOT Curb Inlets

M
OR IN
STDRA

M
AD
IN E
US
A.

Isometric View

24" E.J. 1854-05


Bolt-Down Ring & Cover
6"
Rear

STORM
DRAIN
3' - 8"

Left

Right
MADE
IN USA.

6" Front

6" 10'-0" 10'-0" 6"

Plan View
Materials & Features
CONCRETE: 5,000 PSI
-No Scale-
REINFORCING: per ASTM A-615 or A-185 All dimensions subject to allowable
H-20 LOADING specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "III" Curb Inlet, 3' - 8" x 20' Grand Prairie


TX 15.13 01-25-10
Houston
San Antonio District HEIDELBERGCEMENT Group
TXDOT Curb Inlets

M
OR IN
STDRA

M
AD
E
IN
US
A.

M
OR IN
STDRA
M
AD
E

IN
US
A.

Isometric View

24" E.J. 1854-05


Bolt-Down Ring & Cover (Typ.)
6" Rear

STORM STORM
3' - 8"

DRAIN DRAIN

Right
Left

MADE MADE
IN USA. IN USA.

6" Type "III" Front Type "II"


6" 10'-0" 10'-0" 10'-0" 6"
6" 6" 6"

Plan View

Materials & Features


CONCRETE: 5,000 PSI
-No Scale-
REINFORCING: per ASTM A-615 or A-185
All dimensions subject to allowable
H-20 LOADING specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "V" Curb Inlet, 3' - 8" x 30' Grand Prairie


TX 15.14 01-25-10
Houston
San Antonio District HEIDELBERGCEMENT Group
TXDOT Curb Inlets

IsometricView
10' Curb Inlet (Right Extension)
Plastic Steps @ 14" O.C.
When Depth is 5' or More
6" 6"
Rear

1'-0"
3'-0" to 5'-0"

Left

Right

6"

6" Front

6" 5' - 0" 5' - 0" 6"


6"
Materials & Features
Plan View
CONCRETE: 5,000 PSI
10' Curb Inlet (Right Extension)
REINFORCING: per ASTM A-615 or A-185
H-20 LOADING

Note: -No Scale-


Extension may also be located on All dimensions subject to allowable
left side. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "II" Curb & Grate Inlet - Stage 1 Grand Prairie


Houston TX 15.15 01-25-10
5', 10' & 15' Options HEIDELBERGCEMENT Group
TXDOT Curb Inlets

IsometricView
10' Curb Inlet (Right Extension)

Plastic Steps @ 14" O.C.


When Depth is 5' or More
6" 6"
Rear 1'-0"
3'-0" to 5'-0"

Left

Right

6"

6" Front

Materials & Features 6" 5' - 0" 5' - 0" 6"


CONCRETE: 5,000 PSI 6"
REINFORCING: per ASTM A-615 or A-185 Plan View
H-20 LOADING 10' Curb Inlet (Right Extension)

Note:
-No Scale-
Extension may also be located on
All dimensions subject to allowable
left side. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "SS" Curb & Grate Inlet - Stage 1 Grand Prairie


Houston
TX 15.16 01-25-10
5', 10' & 15' Options HEIDELBERGCEMENT Group
TXDOT Curb Inlets

IsometricView

Plastic Steps
1'-10"

@ 12" O.C.
6" Rear
3'-0" to 5'-0"

13'-0" Max
Right
Left

As Req'd

6" Front
6"
6" 5' - 0" 6" 6" 5' - 0" 6"

Materials & Features Plan View Front View


CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185
H-20 LOADING
-No Scale-
Ship Loose: All dimensions subject to allowable
E.J. V-1700-1 Ring & Cover specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "I" Curb Inlet - Stage 1 Grand Prairie


TX 15.17 01-25-10
Houston
5' - 0" HEIDELBERGCEMENT Group
TXDOT Curb Inlets

IsometricView

Plastic Steps
1'-10"

@ 12" O.C.
6"
Rear
13'-0" Max
3'-0" to 5'-0"

Right
Left

As Req'd

Front 6"
6"
6" 10' - 0" 6"
6" 10' - 0" 6"

Plan View Front View

Materials & Features


CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185
H-20 LOADING
-No Scale-
Ship Loose: All dimensions subject to allowable
E.J. V-1700-1 Ring & Cover specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "I" Curb Inlet - Stage 1 Grand Prairie


TX 15.18 01-25-10
Houston
10' - 0" HEIDELBERGCEMENT Group
TXDOT Curb Inlets

IsometricView

Plastic Steps
@ 12" O.C.
6"
Rear
3'-0" to 5'-0"

Right
Left

6" Front
6" 15' - 0" 6"

Materials & Features Plan View


CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185
H-20 LOADING
-No Scale-
Ship Loose: All dimensions subject to allowable
E.J. V-1700-1 Ring & Cover specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "I" Curb Inlet - Stage 1 Grand Prairie


TX 15.19 01-25-10
Houston
15' - 0" HEIDELBERGCEMENT Group
TXDOT Curb Inlets

IsometricView

Plastic Steps
@ 12" O.C.
6"
Rear
3'-0" to 5'-0"

Left

Right

6" Front
6" 20' - 0" 6"

Plan View
Materials & Features
CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185
H-20 LOADING
-No Scale-
Ship Loose: All dimensions subject to allowable
E.J. V-1700-1 Ring & Cover specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "I" Curb Inlet - Stage 1 Grand Prairie


TX 15.20 01-25-10
Houston
20' - 0" HEIDELBERGCEMENT Group
TXDOT Curb Inlets

MA
DE
IN
U
S
A
.

A.
S
U
IN
DE

M
AD
MA

E
IN
US
A.

IsometricView

E.J. 1846-2
7" 6" Ring & Cover
Rear
6"
1'-3"
1'-9"
15'-0" Max.

DRAIN
Left

DRAIN
2'-3"

Right

1'-6"
MADE
IN USA.

6" Front
6"
6" 5' - 0" 4' - 6" 6"
6"

6" Plan View


6" 5' - 0" 4' - 6" 6"
6"
Front View

Note:
Curb Inlet & Extension Roof Slabs to
Materials & Features be poured as one piece.
CONCRETE: 5,000 PSI Curb Inlet & Extension Risers to

REINFORCING: per ASTM A-615 or A-185 be poured as one piece.


Extension may also be located on
H-20 LOADING
left side.

TITLE PLANT STATE SECTION PAGE . DATE

Type "CI" Curb Inlet w/Extension Grand Prairie


TX 15.21 01-25-10
Houston
5', 10' & 15' Option HEIDELBERGCEMENT Group
TXDOT Curb Inlets

IsometricView

6"
Rear
T.C.
1'-3"
17'-0" Max
5'-0"

Left

Right

6" Front
6"
6" 4' - 9" 6" 6" 4' - 9" 6"

Plan View Front View


Materials & Features
CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185
H-20 LOADING

Ship Loose:
-No Scale-
(1ea.) 29 1/2" x 66 1/2" Galv. Grate All dimensions subject to allowable
w/ 1/2" Galv. Bolts, Nuts & Washers. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "II-G" Curb Inlet, 1-Grate - Stage 1 Grand Prairie


TX 15.22 01-25-10
Houston
4' - 9" x 5' - 0" HEIDELBERGCEMENT Group
TXDOT Curb Inlets

IsometricView

6"
Rear
T.C.
2'-0"
10'-0" Max
Right
5'-0"
Left

Front 6"
6" 6" 10' - 6" 6"
6" 10' - 6" 6"

Plan View Front View

Materials & Features


CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185
H-20 LOADING
Ship Loose:
-No Scale-
(2ea.) 29 1/2" x 66 1/2" Galv. Grates All dimensions subject to allowable
w/ 1/2" Galv. Bolts, Nuts & Washers. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "II-G" Curb Inlet, 2-Grate - Stage 1 Grand Prairie


TX 15.23 01-25-10
Houston
10' - 6" x 5' - 0" HEIDELBERGCEMENT Group
TXDOT Manholes
6" 6' - 0" 6"
6"
Rear
TXDOT

Sewer

Sewer

3'-0"
TXDOT

24"

6'-0" Max.

Right
Left
Front
6"

6" 6' - 0" Max. 6"

Plan View

22" E.J. 1814/1418


Ring & Cover

T.E.

8" 7" 1'-0"


8'-5" Max
6'-0" Max

As Req'd.

6"

6" 6' - 0" Max. 6"


IsometricView
Front View

Materials & Features


CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185 -No Scale-
All dimensions subject to allowable
H-20 LOADING specification tolerances.

TITLE PLANT STATE SECTION PAGE . DATE

Type "A" Manhole Grand Prairie


TX 15.24
Houston 01-25-10
6' - 0" Max. x 6' - 0"Max. HEIDELBERGCEMENT Group
TXDOT Manholes
6" 6' - 0" 6"
TXDOT
6"
Rear

Sewer

Sewer
TXDOT

3'-0"
24"

6'-0" Max.

Right
Left
Front
6"

6" 6' - 0" Max. 6"

Plan View

22" E.J. 1814/1418


Ring & Cover

T.E.

8" 7" 1'-0"


8'-5" Max
6'-0" Max

As Req'd.

6"
IsometricView
6" 6' - 0" Max. 6"

Front View

Materials & Features


CONCRETE: 5,000 PSI
-No Scale-
REINFORCING: per ASTM A-615 or A-185 All dimensions subject to allowable
specification tolerances.
H-20 LOADING
TITLE PLANT STATE .
SECTION PAGE DATE

Type "M" Manhole Grand Prairie


15.25
Houston TX 01-25-10
6' - 0" Max. x 6' - 0"Max. HEIDELBERGCEMENT Group
TXDOT Manholes

IsometricView
T.E.
8" 1'-0"

Plastic Steps
@ 12" O.C.
6"
Rear
30'-0" Max
Right
3'-0"

Left

24"
As Req'd

Front
6" 6"

6" 3' - 0" 6" 6" 3' - 0" 6"

Plan View Front View

Materials & Features


CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185 -No Scale-
All dimensions subject to allowable
H-20 LOADING specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "I" Manhole Grand Prairie


TX 15.26 01-25-10
Houston
3' - 0" x 3' - 0" HEIDELBERGCEMENT Group
TXDOT Manholes

IsometricView
T.E.
8" 1'-0"

Plastic Steps
@ 12" O.C.
6"
Rear
30'-0" Max
Right
3'-0"

Left

24"
As Req'd

Front
6" 6"

6" 3' - 0" 6" 6" 3' - 0" 6"

Plan View Front View

Materials & Features


CONCRETE: 5,000 PSI
-No Scale-
REINFORCING: per ASTM A-615 or A-185
All dimensions subject to allowable
H-20 LOADING specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "II" Manhole Grand Prairie


TX 15.27 01-25-10
Houston
3' - 0" x 3' - 0" HEIDELBERGCEMENT Group
TXDOT Manholes

IsometricView T.E.
10'-0" Max

Plastic Steps
@ 12" O.C.
3' - 0"
6"
Rear
8"
3'-0"
7'-3" Max.

Right

6'-3" Max
Left

As Req'd
8"

Front
6"

6" 7' - 10" Max. 6" 6" 7' - 10" Max. 6"

Plan View Front View

Materials & Features


CONCRETE: 5,000 PSI
-No Scale-
REINFORCING: per ASTM A-615 or A-185 All dimensions subject to allowable
H-20 LOADING specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Grand Prairie
Type "2" Manhole Houston
TX 15.28 01-25-10
HEIDELBERGCEMENT Group
TXDOT Manholes
Plastic Steps
TXDOT
@ 12" O.C.
6"

Sewer

Sewer
Rear
TXDOT

6"

4'-0" to 6'-0"

3'-0"

Right
Left
24"

6"

Front
6"
6" 6"

6" 4' - 0" to 6' - 0" 6"

Plan View

22" E.J. 1814/1418


Ring & Cover

T.E.

7" 1'-0"
18'-5" Max
10"
6'-0" Max

As Req'd.

6"

IsometricView 6" 4' - 0" to 6' - 0" 6"

Front View
Materials & Features
CONCRETE: 5,000 PSI
-No Scale-
REINFORCING: per ASTM A-615 or A-185
All dimensions subject to allowable
H-20 LOADING specification tolerances.

TITLE PLANT STATE SECTION PAGE . DATE

Type "I" Manhole Grand Prairie


TX 15.29 01-25-10
Houston
6' - 0" Max. x 6' - 0"Max. HEIDELBERGCEMENT Group
TXDOT Grate Inlets

IsometricView
6" 9"

36" x 42" x 3" Grate

6"
Rear
28'-9" Max
Right
3'-0"

Left

As Req'd

Front 8"
6"

6" 3' - 0" 6"


3' - 0"
6" 6"
Plan View Front View

Materials & Features


CONCRETE: 5,000 PSI
-No Scale-
REINFORCING: per ASTM A-615 or A-185 All dimensions subject to allowable
H-20 LOADING specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "1" Drop Inlet Grand Prairie


TX 15.30 01-25-10
Houston
3' - 0" x 3' - 0" HEIDELBERGCEMENT Group
TXDOT Grate Inlets

IsometricView

2' - 0"
6" 9"

36" x 42" x 3" Grates


6"
Rear
13'-9" Max
Right
Left
3'-0"

As Req'd

Front
6" 8"
6" 8' - 0" 6"
8' - 0"
6" 6"
Plan View Front View

Materials & Features


CONCRETE: 5,000 PSI
-No Scale-
REINFORCING: per ASTM A-615 or A-185 All dimensions subject to allowable
H-20 LOADING specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "3" Drop Inlet Grand Prairie


Houston TX 15.31 01-25-10
3' - 0" x 8' - 0" HEIDELBERGCEMENT Group
TXDOT Grate Inlets

IsometricView

Galvanized
Grate
6"
Rear
7' - 0" Max.
2' - 0" Min.
5' - 0" Max.
3' - 0" Min.

Right
Left

As Req'd.

6" Front
6"
3' - 0" Min. 3' - 0" Min.
6" 6" 6" 6"
5' - 0" Max. 5' - 0" Max.

Plan View Front View

Materials & Features


CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185 -No Scale-
All dimensions subject to allowable
H-20 LOADING specification tolerances.

TITLE PLANT STATE SECTION PAGE. DATE

Grand Prairie
Type "H" Grate Inlet Houston
TX 15.32 01-25-10
HEIDELBERGCEMENT Group
TXDOT Grate Inlets

IsometricView
6"

E.J. 4880-6
"AD" Frame & Grate

6" Rear
30'-0" Max

TYPE A
2' - 6"

Right
Left
MADE IN USA

V-4880

As Req'd.

EJIW MO/DAY/YR

6" Front
6"

6" 2' - 6" 6" 6" 2' - 6" 6"

Plan View Front View

Materials & Features


CONCRETE: 5,000 PSI
-No Scale-
REINFORCING: per ASTM A-615 or A-185 All dimensions subject to allowable
H-20 LOADING specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "AD" Grate Inlet Grand Prairie


TX 15.33 01-25-10
Houston
2' - 6" x 2' - 6" HEIDELBERGCEMENT Group
TXDOT Grate Inlets

IsometricView

6" x 3" x40" Cast Iron E.J. V-4881 AAD Frame &
I-Beam Cast-In E.J. V-4882 AAD Grate
(E.J. V-4243 I-Beam) 6"
6"
Rear
23'-0" Max
Right
Left
2' - 6"

As Req'd.

6" Front 6"


6" 5' - 0" 6" 6" 5' - 0" 6"

Plan View Front View


(Frame & Grate not Shown)

Materials & Features


CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185 -No Scale-
All dimensions subject to allowable
H-20 LOADING specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "AAD" Grate Inlet Grand Prairie


TX 15.34 01-25-10
Houston
2' - 6" x 5' - 0" HEIDELBERGCEMENT Group
TXDOT Grate Inlets

IsometricView
41 1/2" x 41 1/2"
Galvanized Grate 6"

6"
Rear
25'-0" Max
Right
3'-0"

Left

As Req'd

Front
6" 6"

6" 3' - 6" 6" 6" 3' - 0" 6"

Plan View Front View

Materials & Features


CONCRETE: 5,000 PSI
-No Scale-
REINFORCING: per ASTM A-615 or A-185 All dimensions subject to allowable
specification tolerances.
H-20 LOADING
TITLE PLANT STATE .
SECTION PAGE DATE

Type "I" Drop Inlet - 1 Grate Grand Prairie


TX 15.35 01-25-10
Houston
3' - 0" x 3' - 0" HEIDELBERGCEMENT Group
TXDOT Grate Inlets

41 1/2" x 41 1/2" IsometricView


Galvanized Grates

6" Rear 9"


18'-0" Max
Right
3'-0"

Left

As Req'd

6" Front
6"
6" 7' - 0" 6" 6" 7' - 0" 6"

Plan View Front View

Materials & Features


CONCRETE: 5,000 PSI
-No Scale-
REINFORCING: per ASTM A-615 or A-185 All dimensions subject to allowable
H-20 LOADING specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "I" Drop Inlet - 2 Grate Grand Prairie


TX 15.36 01-25-10
Houston
3' - 0" x 7' - 0" HEIDELBERGCEMENT Group
TXDOT Grate Inlets

IsometricView
41 1/2" x 41 1/2"
Galvanized Grates

6" Rear 9"


12'-0" Max
Right
3'-0"

Left

As Req'd

6" Front
6"
6" 10' - 6" 6" 10' - 6"
6" 6"
Plan View
Front View

Materials & Features


CONCRETE: 5,000 PSI
-No Scale-
REINFORCING: per ASTM A-615 or A-185 All dimensions subject to allowable
H-20 LOADING specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "I" Drop Inlet - 3 Grate Grand Prairie


TX 15.37 01-25-10
Houston
3' - 0" x 10' - 6" HEIDELBERGCEMENT Group
TXDOT Grate Inlets

IsometricView

41 1/2" x 41 1/2"
Galvanized Grate
As Req'd.

6"
Rear
3'-0"

Right
Left

9"

Front
6"
5"

6" 4' - 10" 6" 6" 4' - 10" 6"

Plan View Front View

Materials & Features


CONCRETE: 5,000 PSI
-No Scale-
REINFORCING: per ASTM A-615 or A-185
All dimensions subject to allowable
H-20 LOADING specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "II" Drop Inlet Grand Prairie


TX 15.38 01-25-10
Houston
3' - 0" x 4' - 10" HEIDELBERGCEMENT Group
TXDOT Grate Inlets

1' - 6"
4' - 0"

3"

1' - 6" x 4' - 0" Grate 6"


4' - 6" 4' - 6"
10"

2" 10"
2"

Varies
to 5'-0"

6"
6"

6" 3' - 6" 6"


3' - 6"
3' - 6"

6"

Materials & Features Varies


to 5'-0"
CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185 6"


H-20 LOADING

MAXIMUM PIPE SIZE 30" I.D. R.C.P.

TOP WEIGHT: 1,500 Lbs.

JUNCTION BOX WEIGHTS:


K.O.'s as Required
3'-6" x 3'-6" x 2' ...... 3,900 lbs.
By Customer
3'-6" x 3'-6" x 3' ...... 5,100 lbs.
3'-6" x 3'-6" x 4' ...... 6,300 lbs. -No Scale-
3'-6" x 3'-6" x 5' ...... 7,500 lbs. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type III Drop Inlet, 3' - 6" x 3' - 6" Grand Prairie TX 15.39 01-25-10
San Antonio HEIDELBERGCEMENT Group
TXDOT Grate Inlets
6" 3' - 9" 6"

1' - 6"
27'-0" Max
6"
Connect with 18" R.C.P.
6" (Supplied by Others.)

2' - 0"
As Req'd.

6"
6" 2' - 6" 6"

Front View

6"
Rear

Right
2'-0"
Left
25"

6" Front
6" 3' - 9" 6"

Plan View
(Top Inlet)
(Grate not Shown)

6" Rear
Right
2'-6"
Left

18"

IsometricView 6" Front

6" 2' - 6" 6"

Plan View
(Bottom Junction Box)
Materials & Features
CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185
H-20 LOADING
-No Scale-
Ship Loose:
All dimensions subject to allowable
(1ea.) E.J. 5355Z Frame & Grate specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "AZR" Inlet - 1 Grate Grand Prairie


TX 15.40 01-25-10
Houston
2' - 0" x 3' - 9" HEIDELBERGCEMENT Group
TXDOT Grate Inlets
6" 8' - 6 1/2" 6"

1' - 6"
9"
27'-0" Max

6"
Connect with 18" R.C.P.
6" (Supplied by Others.)
2' - 0"

As Req'd.

6"
6" 2' - 6" 6"

Front View

3' - 9 1/4" 3' - 9 1/4"


6"
Rear
Right
2'-0"

Left

25"

6" Front
6" 8' - 6 1/2" 6"

Plan View
(Top Inlet)
(Grates not Shown)

6" Rear
Right
2'-6"
Left

18"

Front
6"
6" 2' - 6" 6"

Plan View
(Bottom Junction Box)
IsometricView
Materials & Features
CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185
H-20 LOADING
-No Scale-
Ship Loose: All dimensions subject to allowable
(2ea.) E.J. 5355Z Frames & Grates specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "AZR" Inlet - 2 Grate Grand Prairie


TX 15.41 01-25-10
2' - 0" x 8' - 6 1/2" Houston
HEIDELBERGCEMENT Group
TXDOT Grate Inlets

IsometricView
1' - 0"
25'-0" Max

6"
Rear
Right
2'-0"

Left

As Req'd.

6" Front
6"
6" 3' - 9" 6" 6" 3' - 9" 6"

Plan View Front View


(Grate not Shown)
Materials & Features
CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185
H-20 LOADING
-No Scale-
Ship Loose: All dimensions subject to allowable
(1ea.) E.J. 5355Z Frame & Grate specification tolerances.

TITLE PLANT STATE SECTION PAGE . DATE

Type "AZ" Inlet - 1 Grate Grand Prairie


TX 15.42 01-25-10
Houston
2' - 0" x 3' - 9" HEIDELBERGCEMENT Group
TXDOT Grate Inlets

IsometricView

6"
25'-0" Max

Rear
Right
2'-0"

Left

As Req'd.

6" Front
8"

6" 3' - 0" 6" 6" 3' - 0" 6"

Plan View Front View

Materials & Features


CONCRETE: 5,000 PSI
-No Scale-
REINFORCING: per ASTM A-615 or A-185 All dimensions subject to allowable
H-20 LOADING specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "C" Drop Inlet - 1 Grate Grand Prairie


TX 15.43 01-25-10
Houston
2' - 0" x 3' - 0" HEIDELBERGCEMENT Group
TXDOT Grate Inlets

IsometricView
28" x 30"
Galvanized
Grates
6"
22'-0" Max

Rear
Right
2'-0"
Left

As Req'd.

6" Front
8"
6" 5' - 4" 6" 6" 5' - 4" 6"

Plan View Front View

Materials & Features


CONCRETE: 5,000 PSI
-No Scale-
REINFORCING: per ASTM A-615 or A-185 All dimensions subject to allowable
H-20 LOADING specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "C" Drop Inlet - 2 Grate Grand Prairie


TX 15.44 01-25-10
Houston
2' - 0" x 5' - 4" HEIDELBERGCEMENT Group
TXDOT Grate Inlets

IsometricView
28" x 30"
Galvanized
Grates
6"
10'-0" Max

Rear
2'-0"

Right
Left

As Req'd.

6" Front
8"
6" 7' - 8" 6" 6" 7' - 8" 6"

Plan View Front View

Materials & Features


CONCRETE: 5,000 PSI
-No Scale-
REINFORCING: per ASTM A-615 or A-185
All dimensions subject to allowable
H-20 LOADING specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "C" Drop Inlet - 3 Grate Grand Prairie


TX 15.45 01-25-10
Houston
2' - 0" x 7' - 8" HEIDELBERGCEMENT Group
TXDOT Grate Inlets

IsometricView

6" Rear
25'-0" Max
Right
2'-0"

Left

6" Front

6" 3' - 0" 6" 6" 3' - 0" 6"

Plan View Front View

Materials & Features


CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185 -No Scale-
All dimensions subject to allowable
H-20 LOADING specification tolerances.

TITLE PLANT STATE SECTION PAGE . DATE

Type "G" Drop Inlet - 1 Grate Grand Prairie


TX 15.46 01-25-10
Houston
2' - 0" x 3' - 0" HEIDELBERGCEMENT Group
TXDOT Grate Inlets

IsometricView
28" x 30"
Galvanized
Grates
6"
Rear
15'-0" Max
Right
2'-0"
Left

6" Front

6" 5' - 4" 6" 6" 5' - 4" 6"

Plan View Front View

Materials & Features


CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185 -No Scale-
All dimensions subject to allowable
H-20 LOADING specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "G" Drop Inlet - 2 Grate Grand Prairie


TX 15.47 01-25-10
Houston
2' - 0" x 5' - 4" HEIDELBERGCEMENT Group
TXDOT Grate Inlets

IsometricView

24" x 48" x 3" Grates

6"
Rear
22'-0" Max
Right
3'-6"

Left

As Req'd.

Front
6" 6"

6" 3' - 6" 6" 6" 6"


3' - 6"

Plan View Front View

Materials & Features


CONCRETE: 5,000 PSI
-No Scale-
REINFORCING: per ASTM A-615 or A-185
All dimensions subject to allowable
H-20 LOADING specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "XXII" Drop Inlet Grand Prairie


TX 15.48 01-25-10
Houston
3' - 6" x 3' - 6" HEIDELBERGCEMENT Group
TXDOT Grate Inlets

IsometricView

24" x 48" x 3" Grates

6"
Rear
14'-0" Max
3'-6"

Right
Left

As Req'd.

Front
6"
6"
6" 5' - 6" 6" 6" 5' - 6" 6"

Plan View Front View

Materials & Features


CONCRETE: 5,000 PSI
-No Scale-
REINFORCING: per ASTM A-615 or A-185
All dimensions subject to allowable
H-20 LOADING specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "XXIII" Drop Inlet Grand Prairie


TX 15.49 01-25-10
Houston
3' - 6" x 5' - 6" HEIDELBERGCEMENT Group
TXDOT Grate Inlets

IsometricView

24" x 48" x 3" Grates

6"
Rear
10'-0" Max
Right
3'-6"

Left

As Req'd.

Front
6"
6"
6" 7' - 6" 6" 6" 7' - 6" 6"

Plan View Front View

Materials & Features


CONCRETE: 5,000 PSI
-No Scale-
REINFORCING: per ASTM A-615 or A-185
All dimensions subject to allowable
H-20 LOADING specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "XXIV" Drop Inlet Grand Prairie


TX 15.50 01-25-10
Houston
3' - 6" x 7' - 6" HEIDELBERGCEMENT Group
TXDOT Grate Inlets

IsometricView

3' - 0" 4"


24" x 35" x 4 1/2"
Galvanized Grates
8"
6"
Rear
15'-0" Max
1'-6"

Right
Left

As Req'd.

6" Front

6" 6' - 4" 6" 6"


6" 6' - 4" 6"
Plan View Front View

Materials & Features


CONCRETE: 5,000 PSI
-No Scale-
REINFORCING: per ASTM A-615 or A-185
All dimensions subject to allowable
H-20 LOADING specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "D" Drop Inlet - 2 Grate Grand Prairie


TX 15.51 01-25-10
Houston
1' - 6" x 6' - 4" HEIDELBERGCEMENT Group
TXDOT Grate Inlets

IsometricView
Type 4 Galvanized Grate
4' - 0 1/2" x 5' - 6"
6"
Rear
113/4"
1'-1"
15'-0" Max
5'-0"

Right
Left

Front
6" 6"
6"
6" 6' - 0" 6" 6' - 0" 6"

Plan View Front View

Materials & Features


CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185
H-20 LOADING
JUNCTION BOX WEIGHTS:
5' x 6' x 2' ................. 9,575 lbs.
5' x 6' x 3' ............... 12,000 lbs.
5' x 6' x 4' ............... 14,500 lbs. -No Scale-
5' x 6' x 5' ............... 17,000 lbs. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "W-1" Drop Inlet Grand Prairie


TX 15.52 01-25-10
Houston
5' - 0" x 6' - 0" HEIDELBERGCEMENT Group
TXDOT Grate Inlets

IsometricView
Type 4 Galvanized
Grates 113/4" 113/4" 113/4"
6"
Rear
1'-1"
14'-0" Max
Right
Left
5'-0"

As Req'd.

6" Front 6"


6" 12' - 0"
6" 12' - 0" 6" 6"

Plan View Front View

Materials & Features


CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185
H-20 LOADING
JUNCTION BOX WEIGHTS:
5' x 12'-2" x 2' ........... 15,950 lbs.
5' x 12'-2" x 3' ........... 19,650 lbs.
5' x 12'-2" x 4' ........... 23,340 lbs. -No Scale-
5' x 12'-2" x 5' ........... 27,000 lbs. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "W-2" Drop Inlet Grand Prairie


TX 15.53 01-25-10
Houston
5' - 0" x 12' - 0" HEIDELBERGCEMENT Group
TXDOT Grate Inlets

IsometricView

Type 4 Galvanized
Grates
6" Rear
Right
5'-0"

Left

Front
6"
6" 18' - 0" 6"

Plan View
Materials & Features
CONCRETE: 5,000 PSI
-No Scale-
REINFORCING: per ASTM A-615 or A-185
All dimensions subject to allowable
H-20 LOADING specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "W-3" Drop Inlet Grand Prairie


TX 15.54 01-25-10
Houston
5' - 0" x 18' - 0" HEIDELBERGCEMENT Group
TXDOT Grate Inlets

IsometricView

Type 5 Galvanized
Grate

Rear
22'-0" Max
8"

Left
2'-6"

Right

As Req'd.

Front
8"
8"
8" 6' - 0" 8" 8" 6' - 0" 8"

Plan View Front View

Materials & Features


CONCRETE: 5,000 PSI
-No Scale-
REINFORCING: per ASTM A-615 or A-185
All dimensions subject to allowable
H-20 LOADING specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "X-1" Traffic Inlet Grand Prairie


TX 15.55 01-25-10
Houston
2' - 6" x 6' - 0" HEIDELBERGCEMENT Group
TXDOT Grate Inlets

IsometricView

Type 5 Galvanized
Grates

Rear
6"

Right
2'-6"

Left

Front
6"

6" 12' - 0" 6"

Plan View

Materials & Features


CONCRETE: 5,000 PSI
-No Scale-
REINFORCING: per ASTM A-615 or A-185
All dimensions subject to allowable
H-20 LOADING specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "X-2" Traffic Inlet Grand Prairie


TX 15.56 01-25-10
Houston
2' - 6" x 12' - 0" HEIDELBERGCEMENT Group
TXDOT Grate Inlets

IsometricView

Type 5 Galvanized
Grates
6" Rear

Right
2'-6"

Left

6" Front

6" 18' - 0" 6"

Plan View
Materials & Features
CONCRETE: 5,000 PSI
-No Scale-
REINFORCING: per ASTM A-615 or A-185
All dimensions subject to allowable
H-20 LOADING specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "X-3" Traffic Inlet Grand Prairie


TX 15.57 01-25-10
Houston
2' - 6" x 18' - 0" HEIDELBERGCEMENT Group
TXDOT Grate Inlets

IsometricView

Type 5 Galvanized
Grates
6" Rear

Right
2'-6"
Left

6" Front

6" 24' - 0" 6"

Plan View
Materials & Features
CONCRETE: 5,000 PSI
-No Scale-
REINFORCING: per ASTM A-615 or A-185
All dimensions subject to allowable
H-20 LOADING specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "X-4" Traffic Inlet Grand Prairie


TX 15.58 01-25-10
Houston
2' - 6" x 24' - 0" HEIDELBERGCEMENT Group
TXDOT Grate Inlets

IsometricView

Type 3 Galvanized
Grate, 4' - 0 1/2" x 36" 113/4"
8"
Rear
1' - 1"
17'-0" Max
2'-6"

Right
Left

As Req'd.

Front
8"
8" 6' - 0" 8" 8"
8" 6' - 0" 8"
Plan View Front View

Materials & Features


CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185
H-20 LOADING
JUNCTION BOX WEIGHTS:
2'-6" x 6' x 2' ............... 6,750 lbs.
2'-6" x 6' x 3' ............... 8,700 lbs.
2'-6" x 6' x 4' ............. 10,675 lbs. -No Scale-
2'-6" x 6' x 5' ............. 12,650 lbs. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "Y-1" Drop Inlet Grand Prairie


TX 15.59 01-25-10
Houston
2' - 6" x 6' - 0" HEIDELBERGCEMENT Group
TXDOT Grate Inlets
8"

2' - 0"
12" 4"
2'-0"
2"
Varies
to 5'-0"

8"

8" 12' - 2" 8"

4' - 4"

2' - 0"

13' - 4"

8"

3' - 0"
8"

Varies
to 5'-0" 12' - 2"

8"

Materials & Features


CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185
H-20 LOADING K.O.'s as Required
TOP WEIGHT: 5,000 Lbs. By Customer
JUNCTION BOX WEIGHTS:
30" x 12'-2" x 2' ........ 11,570 lbs.
30" x 12'-2" x 3' ........ 14,775 lbs.
30" x 12'-2" x 4' ........ 17,975 lbs. -No Scale-
30" x 12'-2" x 5' ........ 21,175 lbs. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

30" x 12' - 2" Drop Inlet, Type Y-2 Grand Prairie TX 15.60 01-25-10
San Antonio HEIDELBERGCEMENT Group
TXDOT Inlets

Basic Dimensions
Inside Outside Height Weight
Dimensions Dimensions
WxL WxL
(ft.) (ft.) (ft.) (lbs.)
Rebar: 8" o.c. all 4 sides
Exposure: 18" 2.5 x 5 3.5 x 6 3 5,400
" " 4 6,675
" " 5 7,950
6"
" " 6 9,225

I.D. - "W"
I.D. - "L" 2.5 x 10 3.5 x 11 3 8,963
" " 4 10,988
6" " " 5 13,013
" " 6 15,038

Varies 3x5 4x6 3 5,850


to 6' - 0"
" " 4 7,200
" " 5 8,550
" " 6 9,900
6"
3 x 10 4 x 11 3 9,600
" " 4 11,700
" " 5 13,800
" " 6 15,900

3 x 15 4 x 16 3 13,350
Holes as Required
" " 4 16,200
By Customer
" " 5 19,050
" " 6 21,900

4 x 10 5 x 11 3 10,875
" " 4 13,125
" " 5 15,375
" " 6 17,625

Materials & Features 4 x 15 5 x 16 3 15,000


CONCRETE: 5,000 PSI " " 4 18,000
" " 5 21,000
REINFORCING: per ASTM A-615 or A-185
" " 6 24,000
H-20 LOADING

WEIGHTS AND AVAILABLE SIZES: See table.

-No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

TX DOT Stage 1 Inlets Grand Prairie


TX 15.61 01-25-10
Houston
With Variable Depths HEIDELBERGCEMENT Group
TXDOT Inlets

Basic Dimensions
Inside Outside Height Weight
Dimensions Dimensions
WxL WxL
(ft.) (ft.) (ft.) (lbs.)
Rebar: 8" o.c. all 4 sides
Exposure: 18" 3 x 20 4 x 21 3 17,100
" " 4 20,700
" " 5 24,300
6"
" " 6 27,900

I.D. - "W"
I.D. - "L" 4x5 5x6 3 6,500
" " 4 8,250
6" " " 5 9,700
" " 6 11,250

Varies 4 x 20 5 x 21 3 19,125
to 6' - 0"
" " 4 22,875
" " 5 26,625
" " 6 30,375
6"
5x5 6x6 3 7,650
" " 4 9,300
" " 5 10,950
" " 6 12,600

5 x 10 6 x 11 3 12,150
Holes as Required
" " 4 14,550
By Customer
" " 5 16,950
" " 6 19,350

5 x 15 6 x 16 3 16,650
" " 4 19,800
" " 5 22,950
" " 6 26,100

Materials & Features 5 x 20 6 x 21 3 21,150


CONCRETE: 5,000 PSI " " 4 25,050
" " 5 28,950
REINFORCING: per ASTM A-615 or A-185
" " 6 32,850
H-20 LOADING

WEIGHTS AND AVAILABLE SIZES: See table.

-No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Fort Worth DOT Type S1-2 Stage 1 Inlets Grand Prairie TX 15.62 01-25-10
With Variable Depths HEIDELBERGCEMENT Group
TXDOT Inlets

Basic Dimensions
Inside Outside Height Weight
Dimensions Dimensions
WxL WxL
(ft.) (ft.) (ft.) (lbs.)
Rebar: 8" o.c. all 4 sides
Exposure: 18" 3'-8" x 5'-0" 5'-0" x 6'-4" 3 9,175
" " 4 11,175
" " 5 13,175
8"
" " 6 15,175

I.D. - "W"
I.D. - "L" 3'-8" x 10'-0" 5'-0" x 11'-4" 3 14,675
" " 4 17,675
8" " " 5 20,675
" " 6 23,675

Varies 3'-8" x 15'-0" 5'-0" x 16'-4" 3 20,175


to 6' - 0"
" " 4 24,175
" " 5 28,175
" " 6 32,175
8"
3'-8" x 20'-0" 5'-0" x 21'-4" 3 25,675
" " 4 30,675
" " 5 35,675
" " 6 40,675

Holes as Required
By Customer

Materials & Features


CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185

H-20 LOADING

WEIGHTS AND AVAILABLE SIZES: See table.

-No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Fort Worth DOT Type SS1-2 Stage 1 Inlets 15.63


Grand Prairie TX 01-25-10
With Variable Depths HEIDELBERGCEMENT Group
TXDOT Inlets

Rebar: 8" o.c. all 4 sides


Exposure: 18"

6"

I.D. - "W"
I.D. - "L"

6"

Varies
to 6' - 0"

6"

Basic Dimensions
Holes as Required
Inside Outside Height Weight
By Customer
Dimensions Dimensions
WxL WxL
(ft.) (ft.) (ft.) (lbs.)

3x3 4x4 3 4,350


" " 4 5,400
" " 5 6,450
" " 6 7,500

Materials & Features


CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185

H-20 LOADING

WEIGHTS AND AVAILABLE SIZES: See table.

-No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Fort Worth DOT Type U Stage 1 Inlets Grand Prairie TX 15.64 01-25-10
With Variable Depths HEIDELBERGCEMENT Group
TXDOT Junction Boxes

3' - 0"
3' - 6"

2 1/2"

4' - 0"
5' - 0"

9"
1' - 3"
1' - 3"

3' - 6" 4' - 0"

6"
6"

6" 3' - 0" 6"


3' - 0" 3' - 0"

6"

3' - 6"
Materials & Features
CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185 6"


H-20 LOADING

MAXIMUM PIPE SIZE 30" I.D. R.C.P.

TOP WEIGHT: 2,200 Lbs.

JUNCTION BOX WEIGHT: 4,810 Lbs.


K.O.'s as Required
EXTENSION SECTIONS AVAILABLE By Customer
-No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Type "E" Inlet Top for 3' x 3' Junction Box Grand Prairie TX 15.65 01-25-10
HEIDELBERGCEMENT Group
TXDOT Junction Boxes

4' - 0"
6' - 0"
6"

Customer to Specify
6" Opening Size or
Cast-In Ring & Cover

3' - 0"
5' - 0"

6"

Varies
to 5' - 0"

6"

Holes as Required
By Customer
Materials & Features
CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185

H-20 LOADING

TOP SLAB WEIGHT: 1,800 Lbs.

BOTTOM SECTION WEIGHT: 5,850 Lbs. (bottom height = 3' - 0")


7,200 Lbs. (bottom height = 4' - 0")
8,550 Lbs. (bottom height = 5' - 0")
-No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

3' x 5' Junction Box Grand Prairie


Houston TX 15.66 01-25-10
With Variable Depths HEIDELBERGCEMENT Group
TXDOT Junction Boxes

4' - 0"
6' - 0"
9"

10"

9"

Varies Customer to Specify


to 5' - 0" Opening Size or
6" Cast-In Ring & Cover
6"

6"
3' - 0"
5' - 0"
6" 3' - 0" 6"
6"

Varies
to 5' - 0"

6"

Materials & Features


Thin Wall K.O.'s as
CONCRETE: 5,000 PSI
Required By Customer
REINFORCING: per ASTM A-615 or A-185

H-20 LOADING

TOP SECTION WEIGHT: 2,100 Lbs.

BOTTOM SECTION WEIGHT: 5,850 Lbs. (bottom height = 3' - 0")


7,200 Lbs. (bottom height = 4' - 0")
8,550 Lbs. (bottom height = 5' - 0")
-No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

3' x 5' Junction Box w/Variable Depths Grand Prairie


15.67 01-25-10
Houston TX
and w/"C" Type Top HEIDELBERGCEMENT Group
TXDOT Ground Boxes Galvanized Bolt
Down Cover
3" Tall Lettering

D OT
TX IBER
F

6"
Galvanized
Cast-In Frame
2' - 0"
3' - 0"

6"

60"
#4 Dowel Bar
(2 per Wall)

3" Terminators 3" Terminators


Per Job Requirement Per Job Requirement
Materials & Features
CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185.

BUTYL GASKET FOR WATERTIGHT JOINTS


-No Scale-
WEIGHT: 4,500 lbs. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

2' - 0" x 3' - 0" x 60" Type 1 Ground Box Grand Prairie TX 15.68 01-25-10
HEIDELBERGCEMENT Group
TXDOT Ground Boxes

Galvanized Bolt
Down Cover
3" Tall Lettering

D OT
TX ER
FIB

Galvanized
6" Cast-In Frame

3' - 0" 4' - 0"

6"

#4 Dowel Bar
60" (2 per Wall)

4" Terminators
Per Job Requirement

3" Terminators
Per Job Requirement

Materials & Features


CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185.

BUTYL GASKET FOR WATERTIGHT JOINTS

WEIGHT: 5,250 lbs. -No Scale-


All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

3' - 0" x 3' - 0" x 60" Type 2 Pull Box Grand Prairie TX 15.69 01-25-10
HEIDELBERGCEMENT Group
TXDOT Ground Boxes

3" Tall Lettering

. S . H
M
C.T. ER HIG E
A N G TAG
D VOL
1/ " thick Galvanized Cover
4
w/ 1 1/4" x 1 1/4" x 1/4"
Angle Stiffeners

20"
32" 1' - 0"
2' - 0"

4" Typ.

22"

12" x 12" x 2 1/4" Deep


K.O's Centered on All
Four Sides

Materials & Features


CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185.

BUTYL GASKET FOR WATERTIGHT JOINTS -No Scale-


All dimensions subject to allowable
specification tolerances.
WEIGHT: 675 lbs.
TITLE PLANT STATE .
SECTION PAGE DATE

1' x 2' x 22" Type 1 Pull Box Grand Prairie TX 15.70 01-25-10
HEIDELBERGCEMENT Group
TXDOT Ground Boxes

3" Tall Lettering

. M .S. IGH
T
C. ER H
A N G TAGE
D VOL
1/ " thick Galvanized Cover
4
w/ 1 1/4" x 1 1/4" x 1/4"
Angle Stiffeners

32"
44" 2' - 0"
3' - 0"

4" Typ.

3' - 0"

12" x 12" x 2 1/4" Deep


K.O's Centered on
Short Sides

12" x 24" x 2 1/4" Deep


K.O's Centered on
Long Sides

Materials & Features


CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185.

BUTYL GASKET FOR WATERTIGHT JOINTS -No Scale-


All dimensions subject to allowable
specification tolerances.
WEIGHT: 1,700 lbs.
TITLE PLANT STATE .
SECTION PAGE DATE

2' x 3' x 3' Type 2 Pull Box Grand Prairie TX 15.71 01-25-10
HEIDELBERGCEMENT Group
TXDOT Ground Boxes

3" Tall Lettering

. M .S. IGH
T
C. ER H
A N G TAGE
D VOL
1/ " thick Galvanized Cover
4
w/ 1 1/4" x 1 1/4" x 1/4"
Angle Stiffeners

32"
44" 2' - 0"
3' - 0"

4" Typ.
22"

12" x 12" x 2 1/4" Deep


K.O's Centered on
Short Sides

12" x 24" x 2 1/4" Deep


K.O's Centered on
Long Sides

Materials & Features


CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185.

BUTYL GASKET FOR WATERTIGHT JOINTS -No Scale-


All dimensions subject to allowable
specification tolerances.
WEIGHT: 1,040 lbs.
TITLE PLANT STATE .
SECTION PAGE DATE

2' x 3' x 22" Type 1 Pull Box Grand Prairie TX 15.72 01-25-10
HEIDELBERGCEMENT Group
TXDOT Ground Boxes

Cast-In EJ I W
30" x 30" Cast
Iron Hatch

5' - 0" 5' - 0"

8"
MADE IN USA
EAST JORDAN IRON WORKS

COMMUNICATION Slab Top


EAST JORDAN IRON WORKS

- CAUTION -
DO NOT
LIFT MANUALLY

MADE IN USA 6"

4' - 0" 5' - 0"

Top View 6"

21" (Typ.)

3' - 6"
1" (Typ.)

6"
9 1/2" (Typ.)

Ground Box

Isometric View
Materials & Features
CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185
DOWEL BARS AS SPECIFIED
2" PVC END BELLS OR AS SPECIFIED
H-20 LOADING
-No Scale-
TOP SLAB WEIGHT: 2,500 Lbs. All dimensions subject to allowable
JUNCTION BOX WEIGHT: 6,000 Lbs. (4' - 0" O.D.) specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

4' x 4' x 3' - 6" I.D. Ground Box Grand Prairie TX 15.73 01-25-10
HEIDELBERGCEMENT Group
TXDOT Ground Boxes

USA

COMMUNICATION
TXDOT

TXDOT
COMMUNICATION
EJ I W Double Hinge
USA Hatch, Cast-In

6"

Top View
4' - 0" 5' - 0"

6"

3' - 0"

6"

Materials & Features


CONCRETE: 5,000 PSI
Isometric View
REINFORCING: per ASTM A-615 or A-185
H-20 LOADING
K.O. OR PVC END BELLS AS REQUIRED
CABLE RACKS & HOOKS PROVIDED
3" THRU HOLE IN FLOOR FOR DRAIN
JUNCTION BOX WEIGHT: 6,000 Lbs. (3' - 0" I.D.) -No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

4' x 4' x 3' ( I.D.) Type "J" Ground Box Grand Prairie TX 15.74 01-25-10
HEIDELBERGCEMENT Group
TXDOT Ground Boxes

3' - 0" 3' - 0"

6"

Recessed Handle

6"

7"
2' - 0"
2' - 0"
6"
6"

2' - 0"

2' - 0"

6"

6"
6" 2' - 0" 6"

Duct Terminals as Required

Materials & Features


CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185
H-20 LOADING
TOP SLAB WEIGHT: 675 Lbs. -No Scale-
All dimensions subject to allowable
GROUND BOX WEIGHT: 2,175
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

2' x 2' x 2' Type I Handhole Grand Prairie TX 15.75 01-25-10


HEIDELBERGCEMENT Group
TXDOT

Galvanized Door Cast In

6"

3' - 0" 3' - 0"

6"

36"

6"

Materials & Features


CONCRETE: 5,000 PSI
Duct Terminals as Required
REINFORCING: per ASTM A-615 or A-185
H-20 LOADING
BOTTOM SECTION WEIGHT: 4,350 Lbs.
PULL IRONS IN FLOOR AS REQUIRED -No Scale-
All dimensions subject to allowable
3" PVC DRAIN IN FLOOR specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

3' x 3' x 3' Type B Junction Box Grand Prairie TX 15.76 01-25-10
HEIDELBERGCEMENT Group
Electric / Telephone

Galvanized
Bolt Down Door
2" Tall Lettering

SU
DA RV
NG EIL
ER LA
HIG NC
HV E
OL
TA
GE

4"
Galvanized
Cast-In Frame

2' - 0"
3' - 0"

4"

2' - 0"

4"

2" PVC Drain


(Typ. 2 places)

12" Wide x 7" Tall 18 3/4" Wide x 7" Tall


Thinwall Knockout Thinwall Knockout
In Side Walls (Typ.) In End Walls (Typ.)
Materials & Features
CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185

H-20 LOADING

WEIGHT: 1,625 Lbs.

-No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

2' - 0" x 3' - 0" x 24" Type "AS" Junction Box Grand Prairie TX 16.1 01-25-10
HEIDELBERGCEMENT Group
Electric / Telephone

Galvanized Door
Cast In

2" Tall Lettering

LL
AN
GH CE
VO
LT
AG
E

6"

3' - 0"
5' - 0"

6"

3' - 0"

6"

2" PVC Drain


(Typ. 2 places)

18" Wide x 12" Tall


Materials & Features Thinwall Knockout
Typical all Walls
CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185

H-20 LOADING

WEIGHT: 5,850 lbs.

-No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

3' - 0" x 5' - 0" x 36" Type "DS" Junction Box Grand Prairie TX 16.2 01-25-10
HEIDELBERGCEMENT Group
Electric / Telephone

4' - 0"
6' - 0"
6"

Customer to Specify
6"
Opening Size or
Steel Hatch Option

3' - 0"
5' - 0"

6"

36"

6"

Materials & Features


CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185

H-20 LOADING

SLAB TOP WEIGHT: 1,370 Lbs.

BOTTOM SECTION WEIGHT: 5,900 Lbs.

KNOCKOUTS, PIPE OPENINGS OR TERMINATIONS


PROVIDED TO MEET JOB REQUIREMENTS. -No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Grand Prairie
3' x 5' x 36" Handhole Houston TX 16.3 01-25-10
HEIDELBERGCEMENT Group
Electric / Telephone

5' - 0"

6" 7' - 0"

36"

36"

6" 6"

4' - 0"
6' - 0"

6"

36"

6"

Materials & Features


CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185
H-20 LOADING
TOP SECITON WEIGHT: 7,575 Lbs.
BOTTOM SECTION WEIGHT: 7,575 Lbs. -No Scale-
All dimensions subject to allowable
KNOCKOUTS, PIPE OPENINGS OR TERMINATIONS specification tolerances.
PROVIDED TO MEET JOB REQUIREMENTS.
TITLE PLANT STATE .
SECTION PAGE DATE

Grand Prairie
4' x 6' x 6' Electric Manhole TX 16.4 01-25-10
Houston
HEIDELBERGCEMENT Group
Electric / Telephone

5' - 0"

6" 9' - 0"

36"

36"

6" 6"

4' - 0"
8' - 0"

6"

36"

6"

Materials & Features


CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185
H-20 LOADING
TOP SECITON WEIGHT: 9,225 Lbs.
BOTTOM SECTION WEIGHT: 9,225 Lbs. -No Scale-
All dimensions subject to allowable
KNOCKOUTS, PIPE OPENINGS OR TERMINATIONS specification tolerances.
PROVIDED TO MEET JOB REQUIREMENTS.
TITLE PLANT STATE .
SECTION PAGE DATE

Grand Prairie
4' x 8' x 6' Telephone Manhole TX 16.5 01-25-10
Houston
HEIDELBERGCEMENT Group
Electric / Telephone

6" 6' - 10"


12' - 10"

4' - 3"

3' - 9"

Customer to Specify
Opening Size or
Cast-In Ring & Cover
5" Typ. 5" Typ.

6' - 0"
12' - 0"

3' - 9"
3' - 3"

6"

Materials & Features


CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185.

BOTTOM WEIGHT: ................. 14,800 Lbs.

TOP WEIGHT: ................. 16,000 Lbs.

H-20 LOADING

KNOCKOUTS, PULL IRONS, TERMINATORS -No Scale-


AND SUMP MAY BE LOCATED AS SPECIFIED. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

6' - 0" x 12' - 0" x 7' - 0" Electrical Manhole Waco TX 16.6 01-25-10
HEIDELBERGCEMENT Group
Electric / Telephone

6' - 10"
6" 12' - 10"

Varies
to 6' - 0"

Customer to Specify
Opening Size or
Cast-In Ring & Cover
5" Typ. 5" Typ.

6' - 0"
12' - 0"

Varies
to 6' - 0"

6"

Materials & Features


CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185.

BOTTOM WEIGHT: 2' ................ 11,300 Lbs.


3' ................ 13,650 Lbs.
4' ................ 16,000 Lbs.
5' ................ 18,350 Lbs.
6' ................ 20,700 Lbs.

TOP WEIGHT: 2' ................ 11,300 Lbs.


3' ................ 13,650 Lbs.
4' ................ 16,000 Lbs.
5' ................ 18,350 Lbs.
6' ................ 20,700 Lbs.

H-20 LOADING
-No Scale-
KNOCKOUTS, PULL IRONS, TERMINATORS All dimensions subject to allowable
AND SUMP MAY BE LOCATED AS SPECIFIED. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

6' - 0" x 12' - 0" Electrical Manhole 16.7 01-25-10


Waco TX
w/Variable Depths HEIDELBERGCEMENT Group
Electric / Telephone

6" 6' - 10"


12' - 10"

4' - 3"
3' - 9"

Customer to Specify
Opening Size or
Cast-In Ring & Cover 8" Typ.
5" Typ.

6' - 0"
12' - 0"

Varies

5" Typ.

6' - 0"
12' - 0"

3' - 9"
3' - 3"

Materials & Features 6"


CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185.

BOTTOM WEIGHT: ................. 14,800 Lbs.

RISER WEIGHT: ................. Varies

TOP WEIGHT: ................. 16,000 Lbs.

H-20 LOADING

KNOCKOUTS, PULL IRONS, TERMINATORS -No Scale-


All dimensions subject to allowable
AND SUMP MAY BE LOCATED AS SPECIFIED.
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

6' - 0" x 12' - 0" Electrical Manhole Waco TX 16.8 01-25-10


w/Variable Riser HEIDELBERGCEMENT Group
Electric / Telephone

24"

24"
CABLE

A A
Plan View

Materials & Features


CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-185.


3/ " Chamfer Around Top
4
WEIGHT: 180 Lbs.
4"

H-20 LOADING

OPTIONAL LETTERING OR ARROW


DESIGNATION AVAIL. ON REQUEST: Elevation A-A
CAN BE MARKED:

CABLE
DUCT

ADDITIONAL ARROW
ARRANGEMENTS:

-No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

24" x 24" Cable Marker Grand Prairie TX 16.9 01-25-10


HEIDELBERGCEMENT Group
Electric / Telephone

82"

154"

38" Dia.

6"

5"
51"

72"
144"

45"

39" 45"
5"
6"

Materials & Features


CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185.

TOP WEIGHT: ................. 15,405 Lbs.

BOTTOM WEIGHT: ................. 14,228 Lbs.

H-20 LOADING
-No Scale-
KNOCKOUTS, PULL IRONS, TERMINATORS
All dimensions subject to allowable
AND SUMP MAY BE LOCATED AS SPECIFIED. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

6' x 12' x 7' Meter Vault Waco TX 16.10 01-25-10


HEIDELBERGCEMENT Group
Electric / Telephone
Hinged Cover with Plate and
Angle Stiffmers as Required
by Loading Selected

3' x 5' Bolt Down Frame


and Cover

Inserts for Cover Bolts


as Required.

6" 6"

3' - 0"
5' - 0"

6"

6"

6" x 18" Thinwall K.O.'s


2 Each End and 2 Each
36"

Side

Materials & Features


CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185


6"

H-20 LOADING

RISER WEIGHT: ...................... 4,100 Lbs.

SLAB BOTTOM WEIGHT: ....... 1,900 Lbs.

KNOCKOUTS OR TERMINATIONS PROVIDED


TO MEET JOB REQUIREMENTS. -No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

3' x 5' x 36" Handhole


Grand Prairie TX 16.11 01-25-10
With Slab Bottom HEIDELBERGCEMENT Group
Electric / Telephone

Hinged Cover with Plate and


Angle Stiffmers as Required
by Loading Selected

3' x 5' Bolt Down Frame


and Cover

Inserts for Cover Bolts


as Required.

6" 6"

4' - 0"
8' - 0"
6"

6"
6"

48"
6" x 18" Thinwall K.O.'s
2 Each End and 2 Each
Side
6"

Materials & Features


CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185

H-20 LOADING

TOP SECTION WEIGHT: ........ 10,150 Lbs.

SLAB BOTTOM WEIGHT: ....... 3,400 Lbs.

KNOCKOUTS OR TERMINATIONS PROVIDED


TO MEET JOB REQUIREMENTS. -No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

4' x 8' x 48" Handhole


Grand Prairie TX 16.12 01-25-10
With Slab Bottom HEIDELBERGCEMENT Group
Electric / Telephone

7' - 0"
9' - 0"

8"

39"

Customer to Specify
Opening Size or
Cast-In Ring & Cover 6"

6"

6' - 0"
8' - 0"

6"

45"

8"

Materials & Features


CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185.

BOTTOM WEIGHT: ................. 14,750 Lbs.

TOP WEIGHT: ................. 13,620 Lbs.

H-20 LOADING
-No Scale-
PULL IRONS & KNOCKOUTS as per job requirement. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

6' x 8' x 7' Electrical Manhole Grand Prairie TX 16.13 01-25-10


HEIDELBERGCEMENT Group
Electric / Telephone

4' x 4' Steel Door

6"

4' - 0" 5' - 0"

6"

Varies to
5' - 0"

6"

Materials & Features


CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185
H-20 LOADING
JUNCTION BOX WEIGHT: 6,000 Lbs. (4'-0" I.D.)
-No Scale-
KNOCKOUTS, PVC END BELLS PER JOB REQUIREMENT All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Grand Prairie
4' x 4' Pull Box Houston TX 16.14 01-25-10
Waco HEIDELBERGCEMENT Group
Electric / Telephone

4' x 5' Steel Door

6"

4' - 0" 5' - 0"

6"

Varies
to 5' - 0"

6"

Materials & Features


CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185.

H-20 LOADING

BOTTOM SECTION WEIGHT: 9,750 Lbs. (4' x 5' x 5' Box)


-No Scale-
KNOCKOUTS, PVC END BELLS PER JOB REQUIREMENT All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Grand Prairie
4' x 5' Pull Box Houston TX 16.15 01-25-10
HEIDELBERGCEMENT Group
Electric / Telephone

8' - 0" 8' - 0"

8"

3' - 6"

6"

Customer to Specify
Opening Size or
Cast-In Ring & Cover
8"

7' - 0" 7' - 0"

6"

3' - 6"

8"

Materials & Features


CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185
H-20 LOADING
TOP SECTION WEIGHT: 14,275 Lbs. (7' x 7' x 3'-6" Top)
BOTTOM SECTION WEIGHT: 14,275 Lbs. (7' x 7' x 3'-6" Bottom) -No Scale-
All dimensions subject to allowable
KNOCKOUTS, PVC END BELLS PER JOB REQUIREMENT specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

7' x 7' x 7' Manhole Grand Prairie TX 16.16 01-25-10


HEIDELBERGCEMENT Group
Electric / Telephone

9' - 0" 9' - 0"

8"

Varies
to 5' - 0"

6"

Customer to Specify
Opening Size or
Cast-In Ring & Cover
6"

8' - 0" 8' - 0"

6"

Varies
to 5' - 0"

8"

Materials & Features


CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185
H-20 LOADING
TOP SECTION WEIGHT: 26,000 Lbs. (8' x 8' x 5') Top Max.
-No Scale-
BOTTOM SECTION WEIGHT: 26,000 Lbs. (8' x 8' x 5') Bottom Max. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Grand Prairie
8' x 8' Manhole Houston TX 16.17 01-25-10
HEIDELBERGCEMENT Group
Electric / Telephone

4' - 0"
4' - 0"

6"

Slab Top

Customer to Specify
Opening Size or
Cast-In Ring & Cover
6"
7"

6" 3' - 0"


3' - 0"

6"

Varies

Varies

6"
6"

6" 3' - 0" 6"

Pull Box

Materials & Features


CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185
H-20 LOADING
KNOCK-0UTS, PULLING IRONS, ETC. AS REQUIRED
TOP SLAB WEIGHT: 1,180 Lbs. -No Scale-
All dimensions subject to allowable
JUNCTION BOX WEIGHT: specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

3' x 3' Standard Pull Box


Grand Prairie TX 16.18 01-25-10
With Variable Depths HEIDELBERGCEMENT Group
Electric / Telephone

Safety Latch

4' - 0" 4' - 0"

6"

2 x 2 Galv
F&C Cast-in
6"

3' - 0"
3' - 0"

6"

36"

6"
Materials & Features
CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185
H-20 LOADING
KNOCK-0UTS, PULLING IRONS, ETC. AS REQUIRED
TOP SLAB WEIGHT: -No Scale-
All dimensions subject to allowable
JUNCTION BOX WEIGHT: specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

3' x 3' 1-Piece Manhole Grand Prairie TX 16.19 01-25-10


HEIDELBERGCEMENT Group
Electric / Telephone

5' - 0" 5' - 0"

6"

Slab Top

Customer to Specify
Opening Size or
Cast-In Ring & Cover
6"
7"

6" 4' - 0" 4' - 0"

6"

Varies

Varies

6"
6"

6" 4' - 0" 6"

Pull Box

Materials & Features


CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185
H-20 LOADING
KNOCK-OUTS, PVC END BELLS, ETC. PER
JOB REQUIREMENT
-No Scale-
TOP SLAB WEIGHT: 1,850 Lbs. All dimensions subject to allowable
specification tolerances.
JUNCTION BOX WEIGHT:
TITLE PLANT STATE .
SECTION PAGE DATE

4' x 4' Pull Box Grand Prairie TX 16.20 01-25-10


HEIDELBERGCEMENT Group
Electric / Telephone

Hinged Cover with Plate and


Angle Stiffmers as Required
by Loading Selected

3' x 5' Bolt Down Frame


and Cover

Inserts for Cover Bolts


as Required.

6" 6"

4' - 0"
6' - 0"
6"

6"
6"

48"
6" x 18" Thinwall K.O.'s
2 Each End and 2 Each
Side

6"

Materials & Features


CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185

H-20 LOADING

TOP SECTION WEIGHT: ........ 8,225 Lbs.

SLAB BOTTOM WEIGHT: ....... 2,700 Lbs.

KNOCKOUTS OR TERMINATIONS PROVIDED


TO MEET JOB REQUIREMENTS. -No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

4' x 6' x 48" Handhole


Grand Prairie TX 16.21 01-25-10
With Slab Bottom HEIDELBERGCEMENT Group
Electric / Telephone

7' - 0" 7' - 0"

8"

Varies
to 4' - 0"

6"

Customer to Specify
Opening Size or
Cast-In Ring & Cover
6"

6' - 0" 6' - 0"

6"

Varies
to 4' - 0"

8"

Materials & Features


CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185
H-20 LOADING
KNOCK-OUTS, PVC END BELLS, ETC. PER
JOB REQUIREMENT
TOP SECTION WEIGHT: 12,700 Lbs. (6' x 6' x 4' - 0" Top) -No Scale-
All dimensions subject to allowable
BOTTOM SECTION WEIGHT: 12,700 Lbs. (6' x 6' x 4' - 0" Bottom) specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

6' x 6' Manhole Grand Prairie TX 16.22 01-25-10


HEIDELBERGCEMENT Group
Electric / Telephone

9' - 0"
11' - 0"
6"

Varies
to 4' - 0"

6"
Customer to Specify
Opening Size or
Cast-In Ring & Cover

6"

8' - 0"
10' - 0"

6"

Varies
to 4' - 0"

6"

Materials & Features


CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185
H-20 LOADING
KNOCK-OUTS, PVC END BELLS, ETC. PER
JOB REQUIREMENT
TOP SECTION WEIGHT: 18,825 Lbs. (8' x 10' x 4' - 0" Max) -No Scale-
All dimensions subject to allowable
BOTTOM SECTION WEIGHT: 18,825 Lbs. (8' x 10' x 4' - 0" Max) specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

8' x 10' Standard Manhole Grand Prairie TX 16.23 01-25-10


HEIDELBERGCEMENT Group
Electric / Telephone

11' - 2" 11' - 2"

8"

Varies
to 5' - 0"

7"

Customer to Specify
Opening Size or
Cast-In Ring & Cover
7"

10' - 0" 10' - 0"

7"

Varies
to 5' - 0"

8"

Materials & Features


CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185
H-20 LOADING
KNOCK-OUTS, PULL IRONS PER JOB REQUIREMENT
TOP SECTION WEIGHT: 31,000 Lbs. (10' x 10' x 5' - 0" Top Max.)
-No Scale-
BOTTOM SECTION WEIGHT: 31,000 Lbs. (10' x 10' x 5' - 0" Bottom Max.) All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

10' x 10' Manhole Grand Prairie TX 16.24 01-25-10


HEIDELBERGCEMENT Group
Electric / Telephone

3' - 0"
4' - 0"
6"

Customer to Specify
6"
Opening Size or
Steel Hatch Option

2' - 0"
3' - 0"

6"

Varies
to 5' - 0"

6"

Materials & Features


CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185

H-20 LOADING

SLAB TOP WEIGHT: 920 Lbs.

BOTTOM SECTION WEIGHT: 5,400 Lbs. (Bottom Height = 5' - 0")

KNOCKOUTS OR PVC END BELLS PER JOB REQUIREMENT. -No Scale-


All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

2' x 3' Pull Box Grand Prairie TX 16.25 01-25-10


HEIDELBERGCEMENT Group
Electric / Telephone

Galvanized
Bolt Down Door

6"
Galvanized
Cast-In Frame

2' - 0"
3' - 0"

6"

Varies
to 5' - 0"

6"

Materials & Features


CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185

H-20 LOADING

WEIGHT: 5,400 Lbs. (Height = 5' - 0" Max.)


-No Scale-
KNOCKOUTS OR PVC END BELLS PER JOB REQUIREMENT. All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

2' x 3' Pull Box w/ Steel Hatch Grand Prairie TX 16.26 01-25-10
HEIDELBERGCEMENT Group
Electric / Telephone

Galvanized Door Cast In

6"

5' - 0" 5' - 0"

6"

36"

6"

Materials & Features


CONCRETE: 5,000 PSI
Duct Terminals as Required
REINFORCING: per ASTM A-615 or A-185
H-20 LOADING
BOTTOM SECTION WEIGHT: 7,650 Lbs.
PULL IRONS IN FLOOR AS REQUIRED -No Scale-
All dimensions subject to allowable
3" PVC DRAIN IN FLOOR specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

5' x 5' x 3' Type A Junction Box Grand Prairie TX 16.27 01-25-10
HEIDELBERGCEMENT Group
Precast Manhole

36" Cast-In Ring & Cover

6' - 0" 6' - 0"

MA
DE
IN
U
S
A
.

RT 6"
DA

A.
S
U
IN
DE

M
AD
MA

E
IN
US
A.

7"

6"

6"

5' - 0" 6' - 0"


5' - 0"

6"

6"
5' - 0"

6" 5' - 0" 6"

6"

4" Terminators
w/ End Bells as Knockouts as
Specified in Plans Required for
Future
Materials & Features Thru-Hole Sump
with Grate
CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185
H-20 LOADING
TOP SLAB WEIGHT: 2,500 Lbs.
JUNCTION BOX WEIGHT: 11,000 Lbs. (5' x 5' x 5') -No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE SECTION PAGE. DATE

5' x 5' x 5' Manhole


Grand Prairie TX 16.28 01-25-10
Dart Type "C" HEIDELBERGCEMENT Group
Electric / Telephone

5' - 0" 5' - 0"

6"

Slab Top

30" Ring and


Cover Cast-In

6"
7"

6" 4' - 0" 4' - 0"

6"

72"

72"

6"
6"

6" 4' - 0" 6"

Pull Box

Materials & Features


CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185
H-20 LOADING
KNOCK-OUTS, PVC END BELLS, ETC. PER
JOB REQUIREMENT
-No Scale-
TOP SLAB WEIGHT: 1,850 Lbs. All dimensions subject to allowable
specification tolerances.
JUNCTION BOX WEIGHT: 9,975 Lbs.
TITLE PLANT STATE .
SECTION PAGE DATE

4' x 4' x 6' Manhole Grand Prairie TX 16.29 01-25-10


HEIDELBERGCEMENT Group
Precast Manhole

6' - 0" 6' - 0"

6" MA
D E
IN
U
S
A
.

RT
DA

A.
S
U
IN
DE

M
AD
MA

E
IN
US
A.

2' - 0"

6"

36" Cast-In Ring & Cover

6"

5' - 0" 5' - 0"

6"

5' - 0"

6"

4" Terminators
w/ End Bells as
Specified in Plans

Thru-Hole Sump Knockouts as


with Grate Required for
Future
Materials & Features
CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185
H-20 LOADING
KNOCK-OUTS, PVC END BELLS, ETC. PER
JOB REQUIREMENT
TOP SECTION WEIGHT: 6,000 Lbs. (5' x 5' x 2' - 0" Top) -No Scale-
All dimensions subject to allowable
BOTTOM SECTION WEIGHT: 11,000 Lbs. (5' x 5' x 5' - 0" Bottom) specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

5' x 5' x 7' Manhole


Grand Prairie TX 16.30 01-25-10
Dart Type "B" HEIDELBERGCEMENT Group
Electric / Telephone

26" 26"

4"

26"
20"

2' & 3'


Depth
Available

4"

26"

18" Thin Wall K.O.'s

Materials & Features


CONCRETE: 5,000 PSI

REINFORCING: per ASTM A-615 or A-185


TOP WEIGHT: 300 Lbs.
CATCH BASIN WEIGHT:
2' - 800 Lbs.
3' - 1,100 Lbs. -No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

20" x 20" Pull Box Grand Prairie TX 16.31 01-25-10


HEIDELBERGCEMENT Group
Precast Manhole

6' - 0" 6' - 0"

6"

2' - 0"

6"

3' x 3' Galv. Frame


& Cover Cast-in
6"

5' - 0" 5' - 0"

6"

5' - 0"

6"

4" Terminators
w/ End Bells as
Specified in Plans

Thru-Hole Sump Knockouts as


with Grate Required for
Future
Materials & Features
CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185
H-20 LOADING
KNOCK-OUTS, PVC END BELLS, ETC. PER
JOB REQUIREMENT
TOP SECTION WEIGHT: 6,000 Lbs. (5' x 5' x 2' - 0" Top) -No Scale-
All dimensions subject to allowable
BOTTOM SECTION WEIGHT: 11,000 Lbs. (5' x 5' x 5' - 0" Bottom) specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

5' x 5' x 7' Manhole


Grand Prairie TX 16.32 01-25-10
Dart Type "B3" HEIDELBERGCEMENT Group
Electric / Telephone

6' - 0" 6' - 0"

6"

5' - 0"

6"
3' x 3' Galv. Frame
& Cover Cast-in

6"

5' - 0" 5' - 0"

6"

5' - 0"

6"
4" Terminators
w/ End Bells as
Specified in Plans
Materials & Features
CONCRETE: 5,000 PSI
Thru-Hole Sump Knockouts as
with Grate Required for
REINFORCING: per ASTM A-615 or A-185 Future
H-20 LOADING
KNOCK-OUTS, PVC END BELLS, ETC. PER
JOB REQUIREMENT
TOP SECTION WEIGHT: 11,000 Lbs. (5' x 5' x 5' - 0" Top) -No Scale-
All dimensions subject to allowable
BOTTOM SECTION WEIGHT: 11,000 Lbs. (5' x 5' x 5' - 0" Bottom) specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

5' x 5' x 10' Manhole


Grand Prairie TX 16.33 01-25-10
Dart Type "D3" HEIDELBERGCEMENT Group
Electric / Telephone

6' - 0" 6' - 0"

6"

Customer to Specify
Opening Size or
Cast-In Ring & Cover
6"

5' - 0" 5' - 0"

6"

5' - 0"

6"

Materials & Features


CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185
H-20 LOADING
TOP SLAB WEIGHT: 4,400 Lbs.
BOTTOM SECTION WEIGHT: 11,000 Lbs. -No Scale-
All dimensions subject to allowable
KNOCKOUTS OR PVC END BELLS PER JOB REQUIREMENT. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

5' x 5' x 5' Manhole Grand Prairie TX 16.34 01-25-10


HEIDELBERGCEMENT Group
Electric / Telephone

6' - 0" 6' - 0"

6"

Varies
to 5' - 0"

6"

Customer to Specify
Opening Size or
Cast-In Ring & Cover
6"

5' - 0" 5' - 0"

6"

Varies
to 5' - 0"

6"

Materials & Features


CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185
H-20 LOADING
TOP SECTION WEIGHT: 11,000 Lbs. (5' x 5' x 5' Top)
BOTTOM SECTION WEIGHT: 11,000 Lbs. (5' x 5' x 5' Bottom) -No Scale-
All dimensions subject to allowable
KNOCKOUTS OR PVC END BELLS PER JOB REQUIREMENT. specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Grand Prairie
5' x 5' Manhole with Variable Depths Houston TX 16.35 01-25-10
HEIDELBERGCEMENT Group
Electric / Telephone

6"

18"
C C

36" 1" PVC Conduit for


Pulling Eyes (Typ.)

8" Wide Thin Wall


K.O.'s (Typ. 4 Sides)

6"

6" 54" 6"


Plan View

72"

3/ "
6" 4

48"

6" (Typ.)

66"

Profile View
(Shown w/ Multi Enclosure Slab)

Surface - Broom Finish


(Typ. all Lids)

18" (Typ.)

48"
End View

Materials & Features Typical Applications:


CONCRETE: 5,000 PSI P.E.C. #36, #56 or # 74 Enclosure
REINFORCING: per ASTM A-615 or A-185 P.E.C. Single Phase Transformer
VAULT WEIGHT: 4,200 Lbs. P.E.C. 45 - 500 KVA 3 Transformer

TITLE PLANT STATE .


SECTION PAGE DATE

E.V.C. Vault #V-4866 Waco TX 16.36 01-25-10


HEIDELBERGCEMENT Group
Electric / Telephone 4 3/4"

32" 9"

8"

14"
Equipment
Opening

48"
K.O. for #56 Enclosure

K.O. for #74 Enclosure

Vault #V-4866

72"

Plan View
Surface - Broom Finish

6"

3/ "
4

Profile View

Surface - Broom Finish

End View

Typical Application:
Materials & Features Top Slab for P.E.C. #36, #56
CONCRETE: 5,000 PSI or # 74 Enclosure
REINFORCING: per ASTM A-615 or A-185
LID WEIGHT: 2,125 Lbs.

TITLE PLANT STATE .


SECTION PAGE DATE

E.V.C. Top Slab #LL-4872 Waco TX 16.37 01-25-10


HEIDELBERGCEMENT Group
Electric / Telephone

12 1/2" 16 1/8"

Equipment
Opening
26 1/2" 48"

Vault #V-4866

72"

Plan View
Surface - Broom Finish

6"

3/ "
4

Profile View
Surface - Broom Finish

End View

Typical Application:
Materials & Features Top Slab for P.E.C. Single Phase
CONCRETE: 5,000 PSI Transformer Vault
REINFORCING: per ASTM A-615 or A-185
LID WEIGHT: 2,325 Lbs.
TITLE PLANT STATE .
SECTION PAGE DATE

E.V.C. Top Slab #LT-4872 Waco TX 16.38 01-25-10


HEIDELBERGCEMENT Group
Electric / Telephone

9"
9"

2" PVC Conduit


Within Slab for
Metering Cable

78"
Vault #V-4866

16 1/2" Equipment
Opening

8" 48 1/2"

78"

Plan View

Surface - Broom Finish

8"

3/ "
4

Profile View

End View

Materials & Features


Typical Application:
CONCRETE: 5,000 PSI
Top Slab for P.E.C. 45 - 500KVA
REINFORCING: per ASTM A-615 or A-185
3 Phase Transformer Vault
LID WEIGHT: 3,825 Lbs.

TITLE PLANT STATE .


SECTION PAGE DATE

E.V.C. Top Slab #LT-7878-H Waco TX 16.39 01-25-10


HEIDELBERGCEMENT Group
Electric / Telephone

6"

1" PVC Conduit


for Pulling Eyes
C

24" (Typ.)
84"

8" Wide Thin Wall


K.O.'s (Typ. 4 Sides)

6"

6" 84" 6"

Vault - Plan View

Surface - Broom Finish

8" 1 1/2"

C
24"
(Typ.)
19 1/2" (Typ.)

49 1/2"

7 1/2" (Typ.)

96"

Vault - Profile View

Typical Application:
Materials & Features
P.E.C. Switchgear Vault
CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185 -No Scale-
VAULT WEIGHT: 3,900 Lbs. (Each Riser Section) All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

E.V.C. Vault #V-9696 Waco TX 16.40 01-25-10


HEIDELBERGCEMENT Group
Electric / Telephone

6"

30"
C C

60"
1" PVC Conduit
for Pulling Eyes

8" Wide Thin Wall


K.O.'s (Typ. 4 Sides)
6"

6" 84" 6"


Vault - Plan View
Surface - Broom Finish

6" 1 1/2"

19 1/2" (Typ.)

49 1/2"

71/2"(Typ.)

Vault - Profile View


(Shown w/Combo Pad Top Slab.)

24"
(Typ.)

1 1/2"
Vault - End View
(Shown w/Combo Pad Top Slab.)

Materials & Features


CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185
VAULT WEIGHT: 3,400 Lbs. (Each Riser Section)

TITLE PLANT STATE .


SECTION PAGE DATE

E.V.C. Vault #V-7296 Waco TX 16.41 01-25-10


HEIDELBERGCEMENT Group
Electric / Telephone
14" 36"

K.O. 8"

26" 12"

Equipment
Opening
12" K.O. 42" 84"

Vault #V-7296

K.O. 8"

96"

Plan View

Surface - Broom Finish (Typ.)

6"

1 1/2"

Profile View

End View
Typical Application:
Materials & Features Top Slab for P.E.C. Combination
CONCRETE: 5,000 PSI Vault
REINFORCING: per ASTM A-615 or A-185
LID WEIGHT: 4,700 Lbs.
TITLE PLANT STATE .
SECTION PAGE DATE

E.V.C. Top Slab #LC-8496 Waco TX 16.42 01-25-10


HEIDELBERGCEMENT Group
Electric / Telephone

9"

20"
2" PVC Conduit
Within Slab for
Metering Cable

Equipment
Opening
57" 120"

Vault #V-7296

120"

Plan View

Surface - Broom Finish (Typ.)

8"

1 1/2"

Profile View

End View

Materials & Features Typical Application:


CONCRETE: 5,000 PSI
Top Slab for P.E.C. 750 - 3000 KVA
REINFORCING: per ASTM A-615 or A-185 3Transformer.
LID WEIGHT: 9,800 Lbs.
TITLE PLANT STATE .
SECTION PAGE DATE

E.V.C. Top Slab #LT-120120-H Waco TX 16.43 01-25-10


HEIDELBERGCEMENT Group
Electric / Telephone
6"

48"

60"

8" Wide Thin Wall 1" PVC Conduit


K.O.'s (Typ. 4 Sides) for Pulling Eyes

6"

6" 132" 6"

Surface - Broom Finish (Typ.) Plan View

8" 11/2"

84"

20" (Typ.)

8" (Typ.)
Profile View

Materials & Features Typical Application:


End View
CONCRETE: 5,000 PSI
P.E.C. Submersible Switchgear
REINFORCING: per ASTM A-615 or A-185 and Splice Box
LID WEIGHT: 7,800 Lbs.
VAULT WEIGHT: 16,800 Lbs.

TITLE PLANT STATE .


SECTION PAGE DATE

E.V.C. Vault #V-7214484 Waco TX 16.44 01-25-10


HEIDELBERGCEMENT Group
Electric / Telephone

19"

EJIW

ELECTRIC

USA
72"

Vault #V-7214484

144"

Plan View

EJIW #V-5660 Frame & Cover

8"

1 1/2"

Profile View

End View

Typical Application:
Materials & Features Top Slab for P.E.C. Submersible
CONCRETE: 5,000 PSI Switchgear and Splice Box
REINFORCING: per ASTM A-615 or A-185
LID WEIGHT: 7,800 Lbs.

TITLE PLANT STATE .


SECTION PAGE DATE

E.V.C. Top Slab #LT-72144 Waco TX 16.45 01-25-10


HEIDELBERGCEMENT Group
Electric / Telephone

96"

16"

Equipment
Equipment

Opening
Opening
96" 64"

8 1/2"

43" 18" 16"

Top Slab - Plan View


(Top Slab #LSG-9696-H)

8"

1 1/2"

Top Slab - Profile View


(Top Slab #LSG-9696-H)

Top Slab - End View


(Top Slab #LSG-9696-H)

Typical Application:
Top Slab for P.E.C. Switchgear Vault

Materials & Features


CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185 -No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

E.V.C. Top Slab #LSG-9696 Waco TX 16.46 01-25-10


HEIDELBERGCEMENT Group
Electric / Telephone
14" 36"

K.O. 8"

26"

Equipment
Opening
12" Transformer 42"
84"
Opening Knockout

Vault #V-7296
K.O. 8"
12"

96"

Plan View 24" x 36" Access Hatch

Surface - Broom Finish (Typ.)

6"

1 1/2"

Profile View

End View
Typical Application:
Materials & Features Top Slab for E.V.C. Combination
CONCRETE: 5,000 PSI Vault
REINFORCING: per ASTM A-615 or A-185
LID WEIGHT: 4,700 Lbs.

TITLE PLANT STATE .


SECTION PAGE DATE

E.V.C. Top Slab #LC-8496A Waco TX 16.47 01-25-10


With Access Hatch HEIDELBERGCEMENT Group
Electric / Telephone 24" x 36" Access Hatch
w/Locking Mech
96"
35 1/2"

6"

18" 18"

36" Knock Out - Switch Gear

Knock Out - #74 Enclosure

24"

62" 62" 96"


Knock Out - Switch Gear

10 1/2"
Knock Out - #74 Enclosure 10 1/2"

14" 14"
19" (Typ.)

Top Slab - Plan View


(Top Slab #LVSG-9696)
1/
4" "V" Notch for
Locating K.O.'s

8"

1 1/2"

Top Slab - Profile View


(Top Slab #LJVSG-9696)

Broom Finish

Top Slab - End View


(Top Slab #LJVSG-9696)

Materials & Features Typical Application:

CONCRETE: 5,000 PSI Top Slab for P.E.C.Vault w/2 ea. Sectionalizing
Enclosures and/or Upgrade to Switchgears
REINFORCING: per ASTM A-615 or A-185
w/Access Hatch.

TITLE PLANT STATE .


SECTION PAGE DATE

Waco
E.V.C. Top Slab #LJVSG-9696 Seguin TX 16.48 01-25-10
HEIDELBERGCEMENT Group
Electric / Telephone 24" x 36" Access Hatch

96"
43 1/4"

35 1/2" 36"

Transformer
12" Opening Knockout
56 5/8"

6" 26"

4 3/4" 96"
4 3/4"

Vault #V-9696
40"

58"
14"

Plan View

Surface - Broom Finish (Typ.)

6"

1 1/2"

Profile View

End View
Materials & Features
CONCRETE: 5,000 PSI Typical Application:
REINFORCING: per ASTM A-615 or A-185 Top Slab for E.V.C. Combination
LID WEIGHT: 4,700 Lbs. Vault

TITLE PLANT STATE .


SECTION PAGE DATE

E.V.C. Top Slab #LJVC-9696 - Junction for 2 ea. 16.49


Waco TX 01-25-10
Sectionalizing Enclosures & 1 Transformer HEIDELBERGCEMENT Group
Electric / Telephone
24" x 36" Access Hatch
96"
43 1/4"

14"

56 5/8"
14 1/4"

4 3/4" 96"

43"

10" 48"

58"
14"

Plan View

Surface - Broom Finish (Typ.)

6"

1 1/2"

Profile View

End View
Materials & Features
CONCRETE: 5,000 PSI Typical Application:
REINFORCING: per ASTM A-615 or A-185 Top Slab for E.V.C. Combination
LID WEIGHT: 4,700 Lbs. Vault

TITLE PLANT STATE .


SECTION PAGE DATE

E.V.C. Top Slab #LJV3-9696 - Junction for 3 ea. 16.50


Waco TX 01-25-10
Sectionalizing Enclosures HEIDELBERGCEMENT Group
Electric / Telephone
RO N WORKS
NI
A
RD

JO
ST
EA
N
IO
A AT
FANIC
U
MM
CO

MA
DE
IN U
. SA

5' - 4" 5' - 4"

10"

Slab Top

30" F & C
Cast-In

8"
11"

10" 4' - 0"


4' - 0"

8"

6' - 0"

6' - 0"

8"
8"

8" 4' - 0" 8"

Pull Box

Materials & Features


CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185
AIRCRAFT LOAD
KNOCK-OUTS, PVC END BELLS, ETC. PER
JOB REQUIREMENT
-No Scale-
TOP SLAB WEIGHT: 3,550 Lbs. All dimensions subject to allowable
specification tolerances.
JUNCTION BOX WEIGHT: 14,050 lbs.
TITLE PLANT STATE .
SECTION PAGE DATE

4' x 4' x 6' Pull Box Grand Prairie TX 16.51 01-25-10


HEIDELBERGCEMENT Group
Electric / Telephone
RO N WORKS
NI
A
RD

JO
ST
EA
N
IO
A AT
FANIC
MU
C OM

MA
DE
IN U
. SA

5' - 0" 5' - 0"

18"

Top

30" F & C
Cast-In

6"
6"

18"
4' - 0" 4' - 0"

6"

6' - 0"
6' - 0"

6"

6"
6" 4' - 0" 6"

Pull Box

Materials & Features


CONCRETE: 5,000 PSI
REINFORCING: per ASTM A-615 or A-185
H-20 LOADING
KNOCK-OUTS, PVC END BELLS, ETC. PER
JOB REQUIREMENT
-No Scale-
TOP WEIGHT: 3,225 Lbs. All dimensions subject to allowable
specification tolerances.
JUNCTION BOX WEIGHT: 11,325 lbs.
TITLE PLANT STATE SECTION PAGE. DATE

4' x 4' x 7' Pull Box Grand Prairie TX 16.52 01-25-10


HEIDELBERGCEMENT Group
Engineering

Comparison of
ASTM C-76 Class Pipe
To
ASTM C-655 D-Load Pipe

D-Load Range Class


1D to 800 D Class 1
801 D to 1,000 D Class 2
1,001 D to 1,350 D Class 3
1,351 D to 2,000 D Class 4
2,000 D to 3,000 D Class 5
Above 3,000 D No Equal Class Pipe

TITLE PLANT STATE .


SECTION PAGE DATE

ASTM C-76 & ASTM C655 Comparison All Plants TX 17.1 01-25-10
HEIDELBERGCEMENT Group
Fill Height Tables are based on: Class I Class IV
1. A soil weight of 120 lbs/ft3. Type 2 Bedding Class II Class V
2. AASHTO HS20 live load. Special Design
Class III
3. Embankment installation.
Fill Height (Feet)
Pipe i.d.
(inches) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
12 1150 650 475 475 500 525 575 650 700 750 825 900 950 1025 1100

TITLE
15 1075 625 475 450 475 525 575 625 700 750 825 875 950 1025 1075
18 1025 600 450 450 475 525 575 625 700 750 825 875 950 1025 1075

Fill Height Table


21 1000 575 450 450 475 525 575 625 700 750 825 875 950 1025 1075
24 950 575 450 450 475 525 575 650 700 775 825 900 950 1025 1100
27 900 550 450 450 475 525 575 650 700 775 825 900 975 1025 1100

Type 2 Bedding: 1' - 15' Fill Height


30 850 550 450 450 475 525 575 650 700 775 825 900 975 1025 1100
33 800 550 425 450 475 525 575 650 700 775 850 900 975 1050 1100
36 775 525 425 450 475 525 600 650 725 775 850 900 975 1050 1125
42 675 525 425 450 475 525 600 650 725 775 850 925 975 1050 1125

PLANT
48 625 500 425 450 475 550 600 650 725 775 850 925 975 1050 1125

All Plants
54 600 475 425 450 500 550 600 650 725 800 850 925 1000 1050 1125

TX
STATE
60 575 450 425 450 500 550 600 675 725 800 850 925 1000 1075 1125
66 575 450 400 450 500 550 600 675 725 800 875 950 1000 1075 1150

17.2
72 575 450 400 450 500 550 600 675 750 800 875 950 1025 1075 1150

SECTION PAGE
78 525 450 400 450 500 550 625 675 750 800 875 950 1025 1075 1150
84 475 425 400 450 500 550 625 675 750 825 875 950 1025 1075 1150

DATE

01-25-10
90 450 425 400 450 500 550 625 675 750 825 875 950 1025 1100 1150
96 425 425 400 450 500 550 625 675 750 825 875 950 1025 1100 1175

American Concrete Pipe Association 2001 #16-200 (Revised March 2001)

HEIDELBERGCEMENT Group
Fill Height Tables are based on: Class I Class IV
1. A soil weight of 120 lbs/ft3. Type 2 Bedding Class II Class V
2. AASHTO HS20 live load. Special Design
Class III
3. Embankment installation.
Fill Height (Feet)
Pipe i.d.

TITLE
(inches) 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
12 1150 1225 1275 1350 1425 1500 1550 1625 1700 1750 1825 1900 1975 2050 2125

Fill Height Table


15 1150 1200 1275 1325 1400 1475 1550 1625 1675 1750 1825 1875 1950 2025 2100
18 1150 1200 1275 1350 1400 1475 1550 1600 1675 1750 1825 1875 1950 2025 2100
21 1150 1200 1275 1350 1400 1475 1550 1625 1675 1750 1825 1900 1975 2025 2100

Type 2 Bedding: 16' - 30' Fill Height


24 1150 1225 1300 1350 1425 1500 1550 1625 1700 1775 1850 1900 1975 2050 2125
27 1150 1225 1300 1350 1425 1500 1575 1625 1700 1775 1850 1925 1975 2050 2125
30 1150 1225 1300 1350 1425 1500 1575 1650 1700 1775 1850 1925 2000 2050 2125
33 1150 1225 1300 1375 1425 1500 1575 1650 1725 1800 1850 1925 2000 2100 2150

PLANT
36 1175 1250 1300 1375 1450 1525 1600 1650 1725 1800 1875 1950 2000 2075 2150

All Plants
42 1175 1250 1325 1375 1450 1525 1600 1675 1725 1800 1875 1950 2025 2075 2150

TX
STATE
48 1175 1250 1325 1400 1450 1525 1600 1675 1725 1800 1875 1950 2025 2075 2150
54 1175 1250 1325 1400 1450 1525 1600 1675 1750 1825 1875 1950 2025 2100 2175

17.3
60 1200 1250 1325 1400 1475 1550 1600 1675 1750 1825 1900 1975 2050 2100 2175

SECTION PAGE
66 1200 1275 1350 1400 1500 1550 1625 1700 1775 1825 1900 1975 2050 2125 2200

DATE
72 1200 1275 1350 1425 1500 1550 1625 1700 1775 1850 1925 2000 2050 2125 2200

01-25-10
78 1200 1275 1350 1425 1500 1575 1625 1700 1775 1850 1925 2000 2050 2125 2200
84 1225 1275 1350 1425 1500 1575 1625 1700 1775 1850 1925 2000 2075 2125 2200
90 1225 1275 1350 1425 1500 1575 1650 1700 1775 1850 1925 2000 2075 2125 2200
96 1225 1300 1350 1425 1500 1575 1650 1700 1775 1850 1925 2000 2075 2150 2200

American Concrete Pipe Association 2001 #16-200 (Revised March 2001)

HEIDELBERGCEMENT Group
Fill Height Tables are based on: Class I Class IV
1. A soil weight of 120 lbs/ft3. Type 2 Bedding Class II Class V
2. AASHTO HS20 live load. Special Design
Class III
3. Embankment installation.
Fill Height (Feet)
Pipe i.d.
(inches) 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45

TITLE
12 2175 2250 2325 2400 2450 2525 2600 2675 2750 2800 2875 2950 3025 3100 3150
15 2150 2225 2300 2375 2450 2500 2575 2650 2725 2775 2850 2925 3000 3075 3125

Fill Height Table


18 2175 2225 2300 2375 2450 2500 2575 2650 2725 2775 2850 2925 3000 3050 3125
21 2150 2250 2300 2375 2450 2525 2600 2650 2725 2800 2875 2925 3000 3075 3150
24 2200 2250 2325 2400 2475 2550 2600 2675 2750 2825 2900 2950 3025 3100 3175
27 2200 2275 2325 2400 2475 2550 2625 2675 2750 2825 2900 2975 3025 3100 3175

Type 2 Bedding: 31' - 45' Fill Height


30 2200 2275 2350 2400 2475 2550 2625 2700 2750 2825 2900 2975 3050 3125 3175
33 2200 2275 2350 2425 2500 2575 2625 2700 2775 2850 2925 2975 3050 3125 3200
36 2225 2300 2375 2425 2500 2575 2650 2725 2800 2850 2925 3000 3075 3150 3225

PLANT
42 2225 2300 2375 2450 2500 2575 2650 2725 2800 2850 2925 3000 3075 3150 3225

All Plants
48 2225 2300 2375 2450 2525 2575 2650 2725 2800 2875 2950 3000 3075 3150 3225

TX
STATE
54 2250 2300 2375 2450 2525 2600 2675 2725 2800 2875 2950 3025 3100 3175 3225
60 2250 2325 2400 2475 2525 2600 2675 2750 2825 2900 2975 3025 3100 3175 3250

17.4
66 2275 2325 2400 2475 2550 2625 2700 2775 2825 2900 2975 3050 3125 3200 3275

SECTION PAGE
72 2275 2350 2425 2500 2575 2625 2700 2775 2850 2925 3000 3075 3125 3200 3275
78 2275 2350 2425 2500 2575 2625 2700 2775 2850 2925 3000 3075 3125 3200 3275

DATE

01-25-10
84 2275 2350 2425 2500 2575 2625 2700 2775 2850 2925 3000 3075 3125 3200 3275
90 2275 2350 2425 2500 2575 2625 2700 2775 2850 2925 3000 3075 3125 3200 3275
96 2275 2350 2425 2500 2575 2625 2700 2775 2850 2925 3000 3075 3125 3200 3275

American Concrete Pipe Association 2001 #16-200 (Revised March 2001)

HEIDELBERGCEMENT Group
Fill Height Tables are based on: Class I Class IV
1. A soil weight of 120 lbs/ft3. Type 3 Bedding Class II Class V
2. AASHTO HS20 live load. Special Design
Class III
3. Embankment installation.
Fill Height (Feet)
Pipe i.d.

TITLE
(inches) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
12 1175 700 550 550 600 650 725 800 875 950 1050 1125 1200 1300 1375 1475 1550 1650
15 1100 675 525 550 575 650 700 775 875 950 1025 1100 1200 1275 1375 1450 1525 1600

Fill Height Table


18 1050 650 525 525 575 650 700 775 850 950 1025 1100 1200 1275 1350 1425 1525 1600
21 1000 625 500 525 575 650 700 775 850 950 1025 1100 1200 1275 1350 1425 1525 1600
24 975 600 500 525 575 650 700 775 850 950 1025 1100 1200 1275 1350 1450 1525 1600

Type 3 Bedding: 1' - 18' Fill Height


27 925 600 500 525 575 650 700 800 875 950 1025 1125 1200 1275 1375 1450 1525 1600
30 875 600 500 525 575 650 725 800 875 950 1050 1125 1200 1300 1375 1450 1525 1625
33 825 575 500 525 575 650 725 800 875 950 1050 1125 1225 1300 1375 1450 1550 1625

PLANT
36 800 575 500 525 575 650 725 800 875 975 1050 1050 1225 1300 1400 1475 1550 1650

All Plants
42 700 575 500 525 600 650 725 800 900 975 1050 1050 1225 1325 1400 1475 1575 1650

TX
STATE
48 650 550 500 525 600 650 725 825 900 975 1075 1050 1250 1325 1425 1475 1575 1650
54 625 525 500 525 600 675 750 825 900 1000 1075 1050 1250 1350 1425 1500 1575 1675

17.5
60 625 500 500 525 600 675 750 825 925 1000 1075 1175 1250 1350 1425 1500 1600 1700

SECTION PAGE
66 600 500 475 550 600 675 750 850 925 1000 1100 1175 1275 1350 1450 1525 1600 1700
72 600 500 475 550 600 675 775 850 925 1025 1100 1200 1275 1375 1450 1525 1625 1725

DATE

01-25-10
78 550 500 475 550 600 675 775 850 925 1025 1100 1200 1300 1375 1475 1550 1625 1725
84 525 500 475 550 625 700 775 850 950 1025 1100 1200 1300 1375 1475 1550 1625 1725
90 475 500 475 550 625 700 775 850 950 1025 1125 1200 1300 1375 1475 1550 1625 1725
96 450 475 475 550 625 700 775 850 950 1025 1125 1200 1300 1375 1475 1550 1650 1725

American Concrete Pipe Association 2001 #16-200 (Revised March 2001)

HEIDELBERGCEMENT Group
Fill Height Tables are based on: Class I Class IV
1. A soil weight of 120 lbs/ft3. Type 3 Bedding Class II Class V
2. AASHTO HS20 live load. Special Design
Class III
3. Embankment installation.
Fill Height (Feet)
Pipe i.d.
(inches) 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35

TITLE
12 1725 1825 1900 2000 2075 2175 2250 2350 2425 2525 2600 2700 2800 2875 2975 3050 3150
15 1700 1775 1875 1950 2050 2125 2225 2300 2400 2475 2575 2675 2750 2850 2925 3025 3100

Fill Height Table


18 1675 1775 1850 1950 2025 2125 2200 2300 2375 2475 2550 2650 2725 2825 2900 3000 3075
21 1675 1775 1850 1950 2025 2125 2200 2300 2375 2475 2550 2650 2750 2825 2900 3000 3075
24 1700 1775 1875 1950 2025 2125 2200 2300 2375 2475 2550 2650 2725 2825 2900 3000 3075

Type 3 Bedding: 19' - 35' Fill Height


27 1700 1775 1875 1950 2050 2125 2225 2300 2400 2475 2575 2650 2750 2825 2925 3000 3100
30 1700 1800 1875 1975 2050 2150 2225 2325 2400 2500 2575 2675 2750 2850 2950 3025 3125
33 1725 1800 1900 1975 2075 2150 2250 2350 2425 2525 2600 2700 2775 2875 2950 3050 3125
36 1750 1825 1925 2000 2100 2175 2275 2350 2450 2525 2625 2725 2800 2900 2975 3075 3150

PLANT
42 1750 1825 1925 2000 2100 2175 2275 2375 2450 2550 2625 2725 2800 2900 3000 3075 3175

All Plants
48 1750 1850 1925 2025 2100 2200 2275 2375 2475 2550 2650 2725 2825 2900 3000 3100 3175

TX
STATE
54 1750 1850 1950 2050 2125 2200 2300 2400 2475 2575 2650 2750 2850 2925 3025 3100 3200
60 1775 1875 1950 2050 2125 2225 2325 2400 2500 2575 2675 2775 2850 2950 3025 3125 3225

17.6
66 1800 1875 1975 2075 2150 2250 2325 2425 2525 2600 2700 2775 2875 2975 3050 3150 3250

SECTION PAGE
72 1800 1900 2000 2075 2175 2250 2350 2450 2525 2625 2725 2800 2900 3000 3075 3175 3250

DATE
78 1800 1900 2000 2075 2175 2250 2350 2450 2525 2625 2725 2800 2900 3000 3075 3175 3250

01-25-10
84 1800 1900 2000 2075 2175 2275 2350 2450 2525 2625 2725 2800 2900 3000 3075 3175 3275
90 1825 1900 2000 2075 2175 2275 2350 2450 2550 2625 2725 2800 2900 3000 3075 3175 3275
96 1825 1900 2000 2100 2175 2275 2350 2450 2550 2625 2725 2800 2900 3000 3075 3175 3275

American Concrete Pipe Association 2001 #16-200 (Revised March 2001)

HEIDELBERGCEMENT Group
Fill Height Tables are based on: Class I Class IV
1. A soil weight of 120 lbs/ft3. Type 4 Bedding Class II Class V
2. AASHTO HS20 live load. Special Design
Class III
3. Embankment installation.
Fill Height (Feet)
Pipe i.d.
(inches) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

TITLE
12 1550 950 750 800 875 950 1075 1200 1325 1450 1575 1700 1825 1950 2100
15 1450 900 750 775 850 950 1050 1150 1275 1400 1525 1650 1775 1900 2050

Fill Height Table


18 1375 850 725 750 825 925 1050 1150 1250 1375 1500 1625 1750 1900 2025
21 1325 850 700 750 825 925 1025 1125 1250 1375 1500 1600 1750 1825 2000
24 1275 825 700 725 800 900 1000 1125 1250 1350 1475 1600 1725 1850 1975

Type 4 Bedding: 1' - 15' Fill Height


27 1150 800 700 725 800 900 1000 1125 1225 1350 1475 1600 1725 1850 1975
30 1025 800 675 725 800 900 1000 1100 1225 1350 1475 1600 1700 1850 1950
33 925 775 675 725 800 900 1000 1100 1225 1350 1475 1600 1700 1825 1950
36 850 750 675 725 800 900 1000 1100 1225 1350 1450 1575 1700 1825 1950

PLANT
42 750 750 650 725 800 900 1000 1100 1225 1350 1450 1575 1700 1825 1950

All Plants
48 700 675 650 725 800 900 1000 1100 1225 1350 1450 1575 1700 1825 1950

TX
STATE
54 675 625 650 725 800 900 1000 1100 1225 1350 1450 1575 1700 1825 1950
60 675 600 650 700 800 900 1000 1100 1225 1350 1450 1575 1700 1825 1950

17.7
SECTION PAGE
66 650 575 625 700 800 900 1000 1125 1225 1350 1475 1600 1700 1825 1950
72 650 575 600 700 800 900 1000 1125 1225 1350 1475 1600 1700 1825 1950

DATE
78 625 575 600 700 800 900 1000 1125 1250 1350 1475 1600 1700 1825 1950

01-25-10
84 575 575 600 700 800 900 1025 1125 1250 1350 1475 1600 1725 1850 1950
90 550 575 600 700 800 900 1025 1125 1250 1375 1475 1600 1725 1850 1950
96 525 575 600 700 800 925 1025 1125 1250 1375 1500 1600 1725 1850 1975

American Concrete Pipe Association 2001 #16-200 (Revised March 2001)

HEIDELBERGCEMENT Group
Fill Height Tables are based on: Class I Class IV
1. A soil weight of 120 lbs/ft3. Type 4 Bedding Class II Class V
2. AASHTO HS20 live load. Special Design
Class III
3. Embankment installation.
Fill Height (Feet)
Pipe i.d.
(inches)

TITLE
16 17 18 19 20 21 22 23
12 2225 2350 2500 2525 2775 2700 3025 3175
15 2175 2300 2450 2550 2700 2825 2950 3100

Fill Height Table


18 2125 2275 2400 2525 2650 2775 2900 3050
21 2125 2250 2375 2500 2625 2750 2875 3000
24 2100 2225 2350 2475 2600 2725 2850 2975

Type 4 Bedding: 16' - 23' Fill Height


27 2075 2200 2325 2450 2575 2700 2825 2950
30 2075 2200 2325 2450 2575 2700 2825 2950
33 2075 2200 2325 2450 2575 2700 2825 2950
36 2075 2200 2325 2450 2550 2675 2800 2925

PLANT

All Plants
42 2050 2175 2300 2425 2550 2675 2800 2925
48 2050 2175 2300 2425 2550 2675 2800 2925

TX
STATE
54 2050 2175 2300 2425 2550 2675 2800 2925
60 2050 2175 2300 2425 2550 2650 2775 2900

17.8
SECTION PAGE
66 2050 2175 2300 2425 2550 2675 2775 2900
72 2050 2175 2300 2425 2550 2675 2800 2900

DATE
78 2075 2175 2300 2425 2550 2675 2800 2900

01-25-10
84 2075 2200 2300 2425 2550 2675 2800 2925
90 2075 2200 2325 2425 2550 2675 2800 2925
96 2075 2200 2325 2450 2550 2675 2800 2925

American Concrete Pipe Association 2001 #16-200 (Revised March 2001)

HEIDELBERGCEMENT Group
Engineering

Arch Pipe Horizontal Elliptical Pipe


Design Equiv. Rise Span Design Equiv. Rise Span
Size Dia. Size Dia.
(In.) (In.) (In.) (In.) (In.) (In.)

1 18 13 1/2 22 1 18 14 23
2 21 15 1/2 26 2 24 19 30
3 24 18 28 1/2 3 27 22 34

4 30 22 1/2 36 1/4 4 30 24 38
5 36 26 5/8 43 3/4 5 33 27 42
6 42 31 5/16 51 1/8 6 36 29 45

7 48 36 58 1/2 7 39 32 49
8 54 40 65 8 42 34 53
9 60 45 73 9 48 38 60
10 72 54 88 10 54 43 68

Note:
Arch and elliptical pipe are supplied in the same classes and D-loads
as round pipe. They are designed to carry the same dead and
live loads as precast round pipe and box culverts.

TITLE PLANT STATE .


SECTION PAGE DATE

TXDOT Equivalents per 464.2 All Plants TX 17.9 01-25-10


HEIDELBERGCEMENT Group
Engineering

FULL FLOW CONSTANTS


for
Circular, Elliptical, Arch Pipes and Box Sections

Use of Tables
Substituting Different Products at Full Flow Conditions

Selection of pipe sizes for flows as determined by Manning's equation:

V = 1.486/n
R.66 S.5

Where; Q = A V

Substitute for V:
Q = A (1.486/n R.66 S.5)

Therefore: Q = K S.5

Example: Substitute a Box (or Boxes) for 2 - 30 inch Arch Pipes

K for 1 - 30 inch Arch Pipe = 368 (from table)


K for 2 - 30 inch Arch Pipes = 736
K for equivalent Box Culvert; 4' x 2' Box = 743 (from table)
Therefore a single 4' x 2' Box Culvert (RCB) will substitute.

CMA - Corrugated Metal Arch - use n = 0.024 for 2 2/3 x 1/2 inch & 0.027 for 3 x 1 inch
CMP - Corrugated Metal Circular Pipe - use n = 0.024
RCA - Reinforced Concrete Arch - use n = 0.012
RCB - Reinforced Concrete Box Culvert - use n = 0.012
RCE - Reinforced Concrete Elliptical - use n = 0.012
RCP - Reinforced Concrete Circular Culvert - use n = 0.012

A = Cross sectional area R = Hydraulic radius = area/inside perimeter


V = Velocity (fps) S = Slope of line (feet/foot)
Q = Flow (cuft/sec) 1 cu ft = 7.48 gallons

TITLE PLANT STATE .


SECTION PAGE DATE

Tables: Full Flow Constants All Plants TX 17.10 01-25-10


HEIDELBERGCEMENT Group
Engineering

Size / Type Equivalent Area Hydraulic K


Size Radius

11 x 18 CMA 15 1.10 0.28 29


15 CMP 15 1.23 0.31 35
12 RCP 0.78 0.25 38
13 X 22 CMA 18 1.60 0.34 48
11 X 18 RCA 15 1.00 0.25 54
18 CMP 1.77 0.38 57
15 RCP 1.23 0.31 70
16 X 25 CMA 21 2.20 0.40 74
21 CMP 2.41 0.44 86
13 1/2 x 22 RCA 18 1.65 0.30 91
18 X 29 CMA 24 2.80 0.45 102
18 RCP 1.77 0.37 113
14 X 23 RCE 18 1.80 0.37 116
24 CMA 3.14 0.50 123
15 1/2 x 26 RCA 21 2.20 0.36 137
21 RCP 2.41 0.44 171
22 X 36 CMA 30 4.40 0.56 185
18 x 28 1/2 RCA 24 2.80 0.45 203
30 CMP 4.91 0.63 222
24 RCP 3.14 0.50 245
19 X 30 RCE 24 3.30 0.49 252
27 X 43 CMA 36 6.40 0.68 306
27 RCP 3.98 0.56 335
22 X 34 RCE 27 4.10 0.55 339
36 CMP 7.07 0.75 361
22 1/2 x 36 1/4 RCA 30 4.40 0.56 368
31 X 50 CMA 42 8.70 0.79 410
30 RCP 4.91 0.63 444
24 X 38 RCE 30 5.10 0.61 456
3X2 RCB 5.78 0.63 524
42 CMP 9.62 0.88 545
33 RCP 5.94 0.69 574
36 X 58 CMA 48 11.40 0.91 589
26 5/8 x 43 3/4 RCA 36 6.40 0.68 613
36 RCP 7.07 0.75 722
4X2 RCB 7.65 0.69 743
29 X 45 RCE 36 7.40 0.74 746
48 CMP 12.57 1.00 778
40 X 65 CMA 54 14.30 1.01 792
39 RCP 8.30 0.81 892
3X3 RCB 8.78 0.78 923
31 5/16 x 57 1/8 RCA 42 8.80 0.80 938
5X2 RCB 9.50 0.74 961
44 X 72 CMA 60 17.60 1.12 1045

TITLE PLANT STATE .


SECTION PAGE DATE

Tables: Full Flow Constants All Plants TX 17.11 01-25-10


HEIDELBERGCEMENT Group
Engineering

Size / Type Equivalent Area Hydraulic K


Size Radius

54 CMP 15.90 1.13 1066


42 RCP 9.62 0.88 1090
6X2 RCB 11.32 0.77 1098
34 X 53 RCE 42 10.20 0.88 1156
45 RCP 11.04 0.94 1311
36 x 58 1/2 RCA 48 11.40 0.90 1315
4x3 RCB 11.65 0.90 1340
49 X 79 CMA 66 21.30 1.23 1345
60 CMP 19.63 1.25 1410
7X2 RCB 13.11 0.80 1422
48 RCP 12.57 1.00 1556
38 X 60 RCE 48 12.90 0.97 1565
8X2 RCB 15.11 0.82 1639
54 X 85 CMA 72 25.30 1.34 1692
5X3 RCB 14.50 0.98 1770
40 X 65 RCA 54 14.30 1.01 1783
66 CMP 23.76 1.38 1818
51 RCP 14.19 1.06 1828
4X4 RCB 15.65 1.04 1990
54 RCP 15.90 1.13 2131
43 X 68 RCE 54 16.60 1.11 2196
6X3 RCB 17.32 1.04 2200
63 X 87 CMA 78 31.00 1.52 2256
72 CMP 28.27 1.50 2293
45 X 73 RCA 60 17.70 1.13 2376
67 X 95 CMA 84 35.00 1.59 2624
7X3 RCB 20.11 1.09 2637
5x4 RCB 19.50 1.16 2660
60 RCP 19.63 1.25 2821
78 CMP 33.18 1.63 2840
48 X 76 RCE 60 20.50 1.23 2910
8X3 RCB 23.11 1.13 3106
91 X 103 CMA 90 40.00 1.70 3135
6X4 RCB 23.32 1.25 3350
84 CMP 38.48 1.75 3460
5x5 RCB 24.50 1.30 3620
66 RCP 23.76 1.38 3636
53 X 83 RCE 66 24.80 1.35 3753
54 X 88 RCA 72 25.60 1.35 3867
10 X 3 RCB 28.61 1.19 3978
7X4 RCB 27.11 1.33 4050
90 CMP 44.18 1.88 4167
72 RCP 28.27 1.50 4587
6X5 RCB 29.32 1.42 4590

TITLE PLANT STATE .


SECTION PAGE DATE

Tables: Full Flow Constants All Plants TX 17.12 01-25-10


HEIDELBERGCEMENT Group
Engineering

Size / Type Equivalent Area Hydraulic K


Size Radius

58 X 91 RCE 72 29.50 1.48 4734


8X4 RCB 31.11 1.39 4790
96 CMP 50.27 2.00 4940
9X4 RCB 34.87 1.65 5503
7X5 RCB 34.11 1.52 5590
78 RCP 33.18 1.63 5679
62 X 102 RCA 84 34.60 1.57 5784
63 X 98 RCE 78 34.60 1.60 5856
6X6 RCB 35.32 1.56 5880
10 X 4 RCB 38.61 1.60 6216
8X5 RCB 39.11 1.60 6630
108 CMP 63.62 2.25 6764
84 RCP 38.48 1.75 6920
11 X 4 RCB 42.32 1.52 6930
9X5 RCB 43.88 1.67 7654
68 X 106 RCE 84 40.10 1.72 7140
7X6 RCB 41.11 1.68 7200
12 X 4 RCB 46.00 1.55 7633
114 CMP 70.88 2.38 7823
72 X 115 RCA 90 44.50 1.77 8056
90 RCP 44.18 1.88 8321
8X6 RCB 47.11 1.78 8575
72 X 113 RCE 90 46.10 1.85 8584
10 X 5 RCB 48.61 1.73 8690
7X7 RCB 48.11 1.82 8880
120 CMP 78.54 2.50 8959
11 X 5 RCB 53.32 1.79 9733
77 1/4 x 122 RCA 96 51.70 1.92 9872
96 RCP 50.27 2.00 9878
9X6 RCB 52.88 1.87 9950
77 x 121 REC 96 52.40 1.97 10190
8x7 RCB 55.11 1.94 10600
12 X 5 RCB 58.00 1.83 10754
10 X 6 RCB 58.61 1.95 11300
102 RCP 56.75 2.13 11620
82 X 128 RCE 102 59.20 2.09 11980
9X7 RCB 61.88 2.05 12350
8X8 RCB 63.11 2.07 12700
11 X 6 RCB 64.32 2.02 12730
108 RCP 63.62 2.25 13530
87 1/8 x 138 RCA 108 66.00 2.17 13690
87 X 136 RCE 108 66.40 2.22 13970
10 X 7 RCB 68.61 2.14 14100
12 X 6 RCB 70.00 2.08 14100

TITLE PLANT STATE .


SECTION PAGE DATE

Tables: Full Flow Constants All Plants TX 17.13 01-25-10


HEIDELBERGCEMENT Group
Engineering

Size / Type Equivalent Area Hydraulic K


Size Radius

9x8 RCB 70.88 2.20 14800


114 RCP 70.88 2.38 15620
11 X 7 RCB 75.32 2.22 15900
10 X 8 RCB 78.61 2.31 17000
9X9 RCB 79.88 2.33 17400
12 X 7 RCB 82.00 2.30 17689
120 RCP 78.54 2.50 17920
96 7/8 x 154 RCA 120 81.80 2.42 18312
97 X 151 RCE 120 82.00 2.46 18490
11 X 8 RCB 86.32 2.41 19200
10 X 9 RCB 88.61 2.46 20000
12 X 8 RCB 94.00 2.50 21400
11 X 9 RCB 97.32 2.57 22609
10 X 10 RCB 98.61 2.59 22894
132 RCP 95.03 2.75 23100
12 X 9 RCB 106.00 2.67 25268
11 X 10 RCB 108.32 2.72 26100
144 RCP 113.10 3.00 29132
12 X 10 RCB 118.00 2.83 29300
11 X 11 RCB 119.32 2.85 29700
12 X 11 RCB 130.00 2.98 33340
12 X 12 RCB 142.00 3.11 37500
15 X 15 RCB 223.00 3.87 68042

Note:
For larger structures see Full Flow Constant Tables in section 6 (Bridge Structures).

TITLE PLANT STATE .


SECTION PAGE DATE

Tables: Full Flow Constants All Plants TX 17.14 01-25-10


HEIDELBERGCEMENT Group
Engineering

Design Red Lights (Project Check List)

1. When specifying floor and invert elevations of a structure, check for sufficient wall height to take
the required holes. Thus one must subtract brick & casting allowance, top slab thickness, and
hole raise, if applicable.

2. Look out for too much pipe into too small a structure. There may be very little support for the
top section when all the blank outs are removed . This is particularly critical when transporting
the structure and when CMP or HDPE is used.

3. Try to put pipes into flat wall structures at as near 90 degrees to the wall as possible. Shallow
angles require large elliptical holes and weaken the wall.

4. Try to maintain at least 2' of cover over your pipes. Less than this may put you into the throat
area, cause conflicts with castings, or cost your client more for high strength pipe. (Note that
these are only some of the problems.)

5. Specify pipe material on your drawing. Hole sizes differ for the same pipe in different materials.

6. Use standard structures wherever possible. They are far more economical.

7. Where possible, use locally manufactured castings. They do not have high transportation costs
and long delivery times.

TITLE PLANT STATE .


SECTION PAGE DATE

Design Red Lights 17.15


All Plants TX 01-25-10
(Project Check List) HEIDELBERGCEMENT Group
Engineering

Standard Hole Diameters

Notes: (1) A dash ( - ) in the table signifies that the pipe is not manufactured or else not readily
available in a particular material.

(2) Values given in the table are those that would normally be used in our plant.
However, the blank out diameter can be varied as required by a given situation.

Pipe Size Pipe Types


(Nominal I.D.) D.I.P. Clay P.V.C. R.C.P. C.M.P.

4" 7" 7" 7" - -


6" 12" 12" 12" - 12"
8" 12" 12" 12" - 12"

10" 16" 16" 16" - 16"


12" 16" 16" 16" 21" 18"
14" 20" - - - -

15" - - 20" 24" 21"


16" 20" 26" - - -
18" 24" 27" 24" 30" 24"

20" 24" 29" - - -


21" - - 26" - 28"
24" 28" 34" 28" 36" 30"

30" 36" 40" 36" 42" 36"


36" 42" 47" 42" 48" 42"
42" - 56" 49" 60" 48'

48" - 61" 55" 66" 54"


54" - - - 72" 60"
60" - - - 78" 66"

66" - - - 84" 72"


72" - - - 92" 78"
78" - - - 96" 84"

84" - - - 108" 92"


90" - - - 113" -
96" - - - 120" 108"

TITLE PLANT STATE .


SECTION PAGE DATE

Standard Hole Diameters All Plants TX 17.16 01-25-10


HEIDELBERGCEMENT Group
Engineering

Instructions & Examples for


Pipe Half Angle Table

(Used with circular structures - see


"Half Angle Diagram" for illustration)

Example No. 1:

To find if a given structure will accomodate two pipes on approximately the


same level, whose size and centerline included angle is specified.

Given: 48" Dia manhole, 12" dia. RCP pipe, 18" dia. RCP pipe, 76 degree
included angle between pipe centerlines.

Procedure: (1.) Turn to "Standard Hole Diameter Table" and find: 12" RCP
hole is 21" dia., and 18" RCP hole is 30" dia.

(2.) Turn to "Pipe Half Angle Table" and find:


(a.) Structure dia. on bottom row. (48")
(b.) Hole dia. of 30" at right side of table.
(c.) Read up and left to intersection finding half angle of 38.68
degrees.
(d.) Repeat procedure for 48" dia. structure & 21" dia. hole,
finding half angle of 25.94 degrees.
(e.) In bottom row below structure dia. find separation angle of
9.53 degrees.
(f.) Add angle found in steps - (c.), (d.) & (e.) giving result of
74.15 degrees.

Result: 74.15 degrees is the normal minimum angle between these pipes in
this structure. Since this angle is less than the 76 degrees specified;
the structure will readily accommodate the pipes in question.

(See next page for example no. 2)

TITLE PLANT STATE .


SECTION PAGE DATE

Instructions & Examples for 17.17 01-25-10


All Plants TX
Pipe Half Angle Table HEIDELBERGCEMENT Group
Engineering

Instructions & Examples for


Pipe Half Angle Table (cont.)

(Used with circular structures - see


"Half Angle Diagram" for illustration)

Example No. 2:

Find the minimum structure for the pipes of Example 1 on the previous page.

Given: Round Structure desired for reasons of economy: Find minimum diameter
structure for 12" dia. RCP pipe, 18" dia. RCP pipe; 76 degree included
angle between pipe centerlines.

Procedure: (1.) Hole Diameters are once again 21" & 30".

(2.) Try 42" dia. structure in "Pipe Half Angle Table".

(3.) Find half angles of:


45.58 deg. for 30" hole, 30.00 deg. for 21" hole, and
10.88 deg. for 42" dia. structure separation angle.

(4.) Total angle is 86.46 deg., which is too large, however, pipe separation
angle of 10.88 deg. can be reduced to 0 deg., and the holes butted
together at the inside wall. This is not recommended practice, but is a
design option, thus the total included angle is 75.58 deg. This is less
than the 76 deg. specified, and the 42" round will just accommodate
the pipes in question.

Note: Structure sizes can also be reduced by decreasing hole diameters. However, the
designer should be aware such procedures increase construction difficulties, may
violate local standards, and should be avoided if at all possible.

For sanitary sewer structures, the hole diameter is determined by the flexible
connector required and the 4" spacing between holes is required.

TITLE PLANT STATE .


SECTION PAGE DATE

Instructions & Examples for 17.18


All Plants TX 01-25-10
Pipe Half Angle Table (cont.) HEIDELBERGCEMENT Group
Engineering

30" Hole

24" CMP

CL
.
ia
"D
48

B D

A
21" Hole
15"
C
MP
CL

NOTE:

A = Half angle for 21" dia. hole in a 48" dia. structure.


B = Separation angle for a 48" dia. structure.
C = Half angle for 30" dia. hole in a 48" dia. structure.
D = Min. angle between pipe CL's.
(Where hole separation is required.)

-No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Pipe Half Angle Diagram All Plants TX 17.19 01-25-10


HEIDELBERGCEMENT Group
Engineering

Half Angle
(Degrees)
90.00 96"
69.64 90"
90.00 61.04 84"
68.21 54.34 78"
90.00 59.00 48.59 72"
66.44 51.79 43.43 66"
90.00 56.44 45.58 38.68 60"
64.16 48.59 40.01 34.23 54"

Hole Diameters
90.00 53.13 41.81 34.85 30.00 48"

(Inches)
90.00 61.04 44.43 35.69 30.00 25.94 42"
59.00 48.59 36.87 30.00 25.38 22.02 36"
45.58 38.68 30.00 24.62 20.92 18.21 30"
41.81 35.69 27.82 22.89 19.47 16.96 28"
34.85 30.00 23.58 19.47 16.60 14.48 24"
30.00 25.94 20.49 16.96 14.48 12.64 21"
25.38 22.02 17.46 14.48 12.37 10.81 18"
22.39 19.47 15.47 12.84 10.98 9.59 16"
19.47 16.96 13.49 11.21 9.59 8.39 14"
16.60 14.48 11.54 9.59 8.21 7.18 12"
13.77 12.02 9.59 7.98 6.84 5.98 10"
42" 48" 60" 72" 84" 96"
10.88 9.53 7.63 6.36 5.45 4.77

Structure Diameter
(Inches)
Separation Angle
(Degrees)

Note: Separation angle is based on a 4" (Min.) space between openings,


measured on the I.D. of the pipe.

TITLE PLANT STATE .


SECTION PAGE DATE

Pipe Half Angle Table All Plants TX 17.20 01-25-10


HEIDELBERGCEMENT Group
Engineering

Maximum Pipe Angle Tables


Use with Square or Rectangular Structures
Instructions / Examples

The following pages give the maximum angle at which a hole of given diameter may
enter the wall of a square or rectangular structure without cutting into the corner area
of the box. In the following discussion, refer to the "Pipe Angle Diagram, Flat Wall
Structures".

The table on page 7.16 gives angle values for situations where the pipe centerline
meets a wall centerline at the inside face of the wall. See the lower diagram on page
7.15. Application is restricted to walls whose inside width and thickness are given at
the bottom of the table. For structures with other dimensions, use the formula for
found at the bottom of the "Pipe Angle Diagram" page. Note that dimension "L" has
no effect in this instance so table values can be used for non-standard box lengths.

Example No. 1: Ref: Table on page 7.16

Given: It is desired to put an 15" RCP pipe through the wide side of a
24" x 36" box at an angle of 30 degrees with the box centerline and
with the pipe centerline passing through the center of the
wall. Can this be done without cutting into the box corner?
Procedure: (1.) Turn to "Standard Hole Diameter Table" and find: 15" RCP
hole is 24" dia.
(2.) Wall thickness for a 24" x 36" box is 6", so inside wall dimension
over wall thickness is 36" / 6".
(3.) Find 36" / 6" column in the table and 24" hole diameter row at
the right side of table.
Result: Read up and over to intersection; finding max. angle of 32.33 degrees.
Max. angle is greater than proposed angle, so we are OK.

Note that a jog is formed in the line when using this system. As a practical matter,
given sufficient distance between structures, this jog can be eliminated by slightly
angling the pipe in the hole. However, the designer should consider this problem.

The diagram and equation found at he top of "Pipe Angle Diagram", page 7.15, is for
those situations where the pipe and hole centerline pass through the center of the
structure. No table values are recommended here due to the large number of possible
"W" and "L" combinations.

TITLE PLANT STATE .


SECTION PAGE DATE

Maximum Pipe Angle Tables 17.21


All Plants TX 01-25-10
(Instructions / Examples) HEIDELBERGCEMENT Group
Engineering

D/2

D/2

W
L L T
CL
- See Note Below -

D/2
W
= Tan -1
L+T
- Sin -1 w2 + (L + T)2

Pipe CL Through Center of Structure

D/2 CL
D/2
W

CL
W

L L T

CL

D/2
W - Sin -1
= Tan -1
T w2 + T2

Pipe CL Meets Structure CL @ Inside Wall - See Table

-No Scale-
All dimensions subject to allowable
specification tolerances.

TITLE PLANT STATE .


SECTION PAGE DATE

Pipe Angle Diagram 17.22


All Plants TX 01-25-10
Flat Wall Structures HEIDELBERGCEMENT Group
Engineering

Table
Pipe CL meets structure CL @ inside wall.

Maximum Angle (Degrees)

0.00 72"
13.98 66"
23.03 0.00 60"
30.41 16.74 54"
36.87 27.02 0.00 48"
42.76 35.34 17.87 0.00 42"
48.26 42.65 29.28 18.55 0.00 36"

Hole Diameters
53.47 49.33 38.64 30.68 19.33 0.00 30"

(Inches)
55.16 51.46 41.50 34.19 24.02 8.14 28"
58.48 55.60 46.95 40.73 32.33 20.23 0.00 24"
60.93 58.62 50.85 45.32 37.96 27.66 15.46 21"
63.35 61.58 54.63 49.72 43.25 34.34 26.21 0.00 18"
64.94 63.53 57.10 52.57 46.63 38.52 32.33 11.72 16"
66.53 65.46 59.53 55.36 49.92 42.52 37.96 20.74 14"
68.11 67.38 61.93 58.11 53.13 46.40 43.25 28.51 12"
69.68 69.28 64.30 60.82 56.29 50.17 48.28 35.53 10"
72" 60" 48" 42" 36" 30" 24" 18"
8" 6" 6" 6" 6" 6" 4" 4"

Inside Wall Dimension


Wall Thickness

TITLE PLANT STATE .


SECTION PAGE DATE

Max. Pipe Angle 17.23


All Plants TX 01-25-10
Flat Wall Structures HEIDELBERGCEMENT Group
Engineering

Cross - Sectional Area


Bar (Sq. in.) per ft.
Bar Size Weight Diameter
Designation* (Lbs. per foot) (inches) At 12" C.-C. At 6" C.-C.

#3 .376 .375 .11 .22


#4 .668 .500 .20 .40
#5 1.043 .625 .31 .62

#6 1.502 .750 .44 .88


#7 2.044 .875 .60 1.20
#8 2.670 1.000 .79 1.58

#9 3.400 1.128 1.00 2.00


#10 4.303 1.270 1.27 2.54
#11 5.313 1.410 1.56 3.12

#14 7.650 1.693 2.25 4.50


#18 13.600 2.257 4.00 8.00

* Bar numbers are based on the number of 1/8 inches included in the
nominal diameter. The nominal diameter of a deformed bar is equivalent
to the diameter of a plain bar having the same weight as the deformed bar.

TITLE PLANT STATE .


SECTION PAGE DATE

Rebar Chart All Plants TX 17.24 01-25-10


HEIDELBERGCEMENT Group
Engineering

Area - Sq. In. per Ft. of Width for Various Spacings


Wire Size Number Nominal Nominal Center to Center Spacing
Diameter Weight
Smooth Deformed Inches Lbs./Lin. Ft. 2" 3" 4" 6" 8" 10" 12"

W31 D31 0.628 1.054 1.86 1.24 .93 .62 .465 .372 .31
W30 D30 0.618 1.020 1.80 1.20 .90 .60 .45 .36 .30
W28 D28 0.597 .952 1.68 1.12 .84 .56 .42 .336 .28

W26 D26 0.575 .934 1.56 1.04 .78 .52 .39 .312 .26
W24 D24 0.553 .816 1.44 .96 .72 .48 .36 .288 .24
W22 D22 0.529 .748 1.32 .88 .66 .44 .33 .264 .22

W20 D20 0.504 .680 1.20 .80 .60 .40 .30 .24 .20
W18 D18 0.478 .612 1.08 .72 .54 .36 .27 .216 .18
W16 D16 0.451 .544 .96 .64 .48 .32 .24 .192 .16

W14 D14 0.422 .476 .84 .56 .42 .28 .21 .168 .14
W12 D12 0.390 .408 .72 .48 .36 .24 .18 .144 .12
W11 D11 0.374 .374 .66 .44 .33 .22 .165 .132 .11

W10.5 0.366 .357 .63 .42 .315 .21 .157 .126 .105
W10 D10 0.356 .340 .60 .40 .30 .20 .15 .12 .10
W9.5 0.348 .323 .57 .38 .285 .19 .142 .114 .095

W9 D9 0.338 .306 .54 .36 .27 .18 .135 .108 .09


W8.5 0.329 .289 .51 .34 .255 .17 .127 .102 .085
W8 D8 0.319 .272 .48 .32 .24 .16 .12 .096 .08

W7.5 0.309 .255 .45 .30 .225 .15 .112 .09 .075
W7 D7 0.298 .238 .42 .28 .21 .14 .105 .084 .07
W6.5 0.288 .221 .39 .28 .195 .13 .097 .078 .065

W6 D6 0.276 .204 .36 .24 .18 .12 .09 .072 .06


W5.5 0.264 .187 .33 .22 .165 .11 .082 .066 .055
W5 D5 .0252 .170 .30 .20 .15 .10 .075 .06 .05

W4.5 0.240 .153 .27 .18 .135 .09 .067 .054 .045
W4 D4 0.225 .136 .24 .16 .12 .08 .06 .048 .04
W3.5 0.211 .119 .21 .14 .105 .07 .052 .042 .035

W3 0.195 .102 .18 .12 .09 .06 .045 .036 .03


W2.9 0.192 .098 .174 .116 .087 .058 .043 .035 .029
W2.5 0.178 .085 .15 .10 .075 .05 .037 .03 .025

W2.1 0.162 .070 .126 .084 .063 .042 .031 .025 .021
W2 0.159 .068 .12 .08 .06 .04 .03 .024 .02
W1.5 0.138 .051 .09 .06 .045 .03 .022 .018 .015
W1.4 0.135 .049 .084 .056 .042 .028 .021 .017 .014

TITLE PLANT STATE .


SECTION PAGE DATE

Welded Wire Mesh Chart All Plants TX 17.25 01-25-10


HEIDELBERGCEMENT Group
Engineering

Cast Iron Products

Load Designations***
Classification Application Proof Load Test

Heavy Duty Suitable for highway traffic loads, or 16,000 lb. 25,000 lbs.* (Ref: Fed. Spec. RR-F-621C)
wheel loads.

Suitable for driveways, parking lots, ramps


Medium Duty and other similar applications where wheel 18,000 lbs.*
loads do not exceed 12,000 lbs.

Suitable for pedestrian areas such as


Light Duty sidewalks, terraces and other areas which
do not receive vehicular traffic.

* Proof load is applied over a 9" x 9" area in center of the casting and held for one
minute without failure or permanent deflection.

Steel Grating and Covers

Load Designations***
Classification Application

H-20 AASHTO H20: 16,000 lbs over 8" x 20" area.**

Traffic H-15 AASHTO H20: 12,000 lbs over 6.9" x 17.30" area.**

H-10 AASHTO H20: 8,000 lbs over 5.6" x 14.1" area.**

These grates and covers are not intended for traffic applications.
Non-Traffic All our standard products exceed 300 PSF.

** Design includes 30% for impact. Load area is increased by twice the distance
center to center of the bearing bars in the direction perpendicular to the bearing
bars.

*** Load designation and classifications are per U.S. Foundry & Mfg. Corp. Products as
shown in their 3rd addition catalog, copyright 1986.

TITLE PLANT STATE .


SECTION PAGE DATE

Casting Specifications All Plants TX 17.26 01-25-10


HEIDELBERGCEMENT Group
Engineering Lap Lap (Typ)
Circumferential Circumferential
Reinforcement Reinforcement

Longitudinal Longitudinal
Reinforcement Reinforcement
Co Co

Ci Ci

Wall Wall
O / S Cage

I / S Cage
RCP & Manhole Single RCP & Manhole Double
Circular Reinforcement Circular Reinforcement
Longitudinal
Reinforcement
RCP (Typ)
Circumferential
Co2 Reinforcement

Lap
Typical At
Ci1 Co
Co1 Opening As T

Ci Co
C i2 T
Wall Ci
Riser At
(Typical)
As
RCP Elliptical Reinforcement Manhole Stopper
Night Cap
Top Slab - Outside
Reinforcement, As7
Top Distribution
Reinforcement, As6 Thickness (T) M
Top Slab - Co Tt Co

As 2
As 2 Bot. Distribution Ci
Reinforcement, As5 H
Co H
Ci Ci Symmetrical Ci
As 4 Rise Symmetrical As 1 Rise (R) As1
Span
Ts Span (S) Thickness (T)
H
H As 4
Ci As 3
Ci
As3 Co

Co Tb Thickness (T) M
Bot. Slab-Outside
Reinforcement, As8

Typical Box Section Typical Box Section


Fill Height Less than 2 Ft. Fill Height 2 Ft. and Greater

Note: Reinforcement areas, concrete covers, material properties and


tolerances per appropriate specification.

TITLE PLANT STATE .


SECTION PAGE DATE

Typical Reinforcing Details All Plants TX 17.27 01-25-10


HEIDELBERGCEMENT Group
Engineering
Radius Pipe
Radius pipe, also referred to as bevelled or mitered Since the maximum permissible drop for any
pipe, incorporates the deflection angle into the pipe joint. given pipe is dependent on manufacturing feasibility,
The pipe is manufactured by shortening one side of the it is essential to coordinate the design of radius pipe
pipe and the amount of shortening or drop for any given with the pipe manufacturer, Many manufacturers
pipe is dependent on manufacturing feasibility. Because have standardardized joint configurations and
of the possibility of greater deflection angles per joint, deflections for specific radi and economics may be
sharper curvature with correspondingly shorter radi can realized by utilizing standard radius pipe.
be obtained with radius pipe than with deflected straight
pipe. As in the case of deflected straight pipe, the radius As illustrated in Figure 4, when concrete pipe is
of curvature which may be obtained by radius pipe is a installed on curved alignment using radius pipe. the pipe
function of the deflection angle per joint, diameter of the sections are oriented such that the plane of the dropped
pipe, length of pipe sections and wall thickness. joint is at right angles to the theoretical circular curve.
The radius of curvature is computed with the equation: Projection of the joints do not converge at a common
point, but are tangents to a common circle of diameter
L
R =
TAN
( D2 + t) (3) equal to the length of pipe sections. The point of curve
(P.C.) is at the midpoint of the last straight pipe and the
where: N point of tangent (P.T.) is one half of the standard pipe
= Total deflection angle of curve, degrees length back from the straight end of the last radius pipe.
N = number of radius pipe The required number of pieces of radius pipe is equal to
L = standard pipe length being used, feet the length of the circular curve in feet divided by the
R = radius of curvature, feet centerline length of the radius pipe (L - 1/2 DROP).
D = inside diameter of the pipe, feet Where possible, minor modifications in the radius are
t = wall thickness of the pipe, feet normally made so this quotient will be a whole number.
From Figure 3, the radius of curvature can be expressed Minimum radius of curvature obtained from equa-
in terms of the drop and is given by the equation: tions (3) and (4) are approximate, but are within a range
of accuracy that will enable the pipe to be readily
L(D + 2t) 1
R =
DROP
( D2 + t)or( DROP
L
2) c
B (4) installed to fit the required alignment. A reasonable
amount of field adjustment is possible for radius pipe by
where: pulling the joints in the same manner as with deflected
Bc = outside diameter of the pipe, feet straight pipe.
L
L
L 2

t

D L P.C.
2
N
t

DROP T.
P. Radius
yin n
La tio
g

True
of irec

Radius
D

Point
R L
t
90 + L
N 2
90 D
Projection of joints do not
converge at common point,
N Drop but are tangents to a
common circle whose
Common method of diameter ia equal to pipe
Manufacturing radius pipe. length.

TITLE PLANT STATE .


SECTION PAGE DATE

Radius Pipe All Plants TX 17.28 01-25-10


- ACPA Design Data 21 - HEIDELBERGCEMENT Group
Engineering

Specifications Applicable to Concrete Pipe and Associated Precast Concrete Products

ASTM C14 /AASHTO M86 - Concrete Sewer, Storm Drain, and Culvert Pipe
ASTM C76 / AASHTO M170 - Reinforced Concrete Culvert, Storm Drain and Sewer Pipe
ASTM C361 - Reinforced Concrete Low Head Pressure Pipe
ASTM C443 - Joints for Circular Concrete Sewer and Culvert Pipe using Rubber Gaskets
ASTM C478 / AASHTO M199 - Precast Reinforced Concrete Manhole Sections
ASTM C497 - Test Methods for Concrete Pipe, Manhole Sections, or Tile
ASTM C506 - Specification for Reinforced Concrete Arch Pipe
ASTM C507 - Specification for Reinforced Concrete Elliptical Pipe
ASTM C655 - Reinforced Concrete D-Load Culvert, Storm Drain, and Sewer Pipe
ASTM C822 - Terminology Relating to Concrete Pipe and Related Products
ASTM C857 - Minimum Structural Design Loading for Underground Precast Concrete
Utility Structures
ASTM C858 - Underground Precast Concrete Utility Structures
ASTM C877 - Specification for External Sealing Bands for Pipe, Manholes and Box Sections
ASTM C890 - Practice for Minimum Structural Design Loading for Monolithic or Sectional
Precast Concrete Water and Wastewater Structures
ASTM C891 - Installation of Underground Precast Concrete Utility Structures
ASTM C913 - Precast Concrete Water and Wastewater Structures
ASTM C923 - Resilient Connectors Between Reinforced Concrete Manhole Structures
and Pipes
ASTM C924 - Practice for Testing Concrete Pipe Sewer Lines by Low-Pressure Air Test
Method
ASTM C969 - Practice for Infiltration and Exfiltration Acceptance Testing of Installed
Precast Concrete Pipe Sewer Lines
ASTM C990 - Specifications for Joints for Concrete Pipe, Manholes, and Precast Box
Sections Using Preformed Flexible Joint Sealants
ASTM C1103 - Practice for Joint Acceptance Testing of Installed Precast Concrete Pipe
Sewer Lines
ASTM C1131 - Practice for Least Cost (Life Cycle) Analysis of Concrete Culvert, Storm
Sewer, and Sanitary Sewer Systems
ASTM C1214 - Practice for Testing Concrete Pipe Sewerlines by Negative Air Pressure
(Vacuum) Method
ASTM C1227 - Precast Concrete Septic Tanks

(Continued on next page.)


TITLE PLANT STATE .
SECTION PAGE DATE

Reference Specifications All Plants TX 17.29 01-25-10


HEIDELBERGCEMENT Group
Engineering

Specifications Applicable to Concrete Pipe and Associated Precast Concrete Products

ASTM C1244 - Test Method for Concrete Sewer Manholes by the Negative Air Pressure
(Vacuum) Test Method
ASTM C1417 - Specification for Manufacture of Reinforced Concrete Sewer, Storm Drain,
and Culvert Pipe for Direct Design
ASTM C1433 - Precast Reinforced Concrete Box Sections for Culverts, Storm Drains,
and Sewers
ASTM C1478 - Resilient Connectors between Pipe and Structures
ASTM C1479 - Installation of Reinforced Concrete Pipe using Standard Installations
ASTM C1504 - Precast Reinforced Concrete Three Sided Structures
ASTM C1577 - Precast Reinforced Concrete Box Sections for Culverts, Storm Drains
and Sewers According to AASHTO LRFD
ASTM C1613 - Precast Concrete Grease Interceptor Tanks
ASTM C1618 - Concrete Sanitary Sewer Pipe by Negative (Vacuum) or Positive
air Pressure
ASTM C1619 - Elastomeric Seals for Joining Concrete Structures
ASTM C1628 - Joints for Concrete Gravity Flow Sewer Pipe, using Rubber Gaskets
AASHTO M259 - Precast Reinforced Concrete Box Sections for Culverts, Storm Drains,
and Sewers
AASHTO M273 - Precast Reinforced Concrete Box Sections for Culverts, Storm Drains,
and Sewers with Less Than 2 Feet of Cover Subjected to Highway Loadings
AWWA C302 - Reinforced Concrete Pressure Pipe, Non-Cylinder Type for Water and
Other Liquids

TITLE PLANT STATE .


SECTION PAGE DATE

Reference Specifications All Plants TX 17.30 01-25-10


HEIDELBERGCEMENT Group
Design Data

American
Concrete Pipe
Association

Technical Series

Loads and Supporting Strengths

Hydraulics of Sewers

Hydraulics of Culverts

Installations

Miscellaneous

Published by
American Concrete Pipe Association 222 W. Las Colinas Blvd., Suite 641 Irving, TX 75039 (972) 506-7216 FAX (972) 506-7682
DD-Title (7/98) Printed in U.S.A.
1996 ACPA Technical data herein are considered reliable, but no guarantee is made or liability assumed.
Design Data
Table of Contents
Date of Issue: March 3, 1997

Design Issue Current


Data Date Print Date Title
Loads and Supporting Strengths
1 10/92 (R) 10/92 Highway Live Loads on Circular Concrete Pipe
6 05/89 (R) 05/89 Concrete Pipe Selection: (Embankment)
7 10/92 (R) 10/92 Concrete Pipe Selection: (Trench)
13 10/92 (R) 10/92 Jacking Concrete Pipe
15 02/84 06/90 Aircraft Loads
16 06/80 (R) 07/91 Railroad Loads
17 05/87 (R) 03/97 Loads & Supporting Strengths of HE & Arch Pipe
22 03/71 06/89 Surcharge Loads
23 07/71 05/89 Transition Width
25 08/74 05/89 3-Edge Bearing Strengths C14 & Clay Pipe
29 06/85 (R) 07/91 Multiple Pipe Installation: (Trench Condition)
31 05/89 05/89 Highway Live Loads on Concrete Arch Pipe
32 07/87 (R) 03/97 Highway Live Loads on Concrete Elliptical Pipe
38 07/80 06/89 Bedding Factors - Trench Installations
40 09/95 10/96 Standard Installation & Bedding Factors
Hydraulics of Sewers
2 03/68 05/89 Friction Factors for Corrugated Metal Pipe
4 10/92 10/92 Hydraulic Capacity of Sewers
5 07/69 03/97 Equivalent Flow Capacity of Sewers
14 12/88 (R) 03/97 Mannings n Values History of Research
35 04/80 05/89 Partial Flow Conditions Circular Concrete Pipe
36 06/80 05/89 Partial Flow Conditions Arch Concrete Pipe
37 07/80 06/88 Partial Flow Conditions Elliptical Concrete Pipe
Hydraulics of Culverts
3 03/68 05/89 Hydraulics Performance Curves
8 10/92 (R) 10/92 Hydraulics of Culverts: 12 - 21 Diameter Pipe
9 01/68 05/89 Hydraulics of Culverts: 24 - 48 Diameter Pipe
10 06/69 06/90 Hydraulics of Culverts: 54 - 90 Diameter Pipe
11 07/69 05/89 Hydraulics of Culverts: 96 - 144 Diameter Pipe
18 10/92 (R) 10/92 Hydraulics of Culverts: HE Concrete & Metal Arch
19 03/70 05/87 Hydraulics of Culverts: HE Concrete & Plate Arch
20 10/80 (R) 01/89 Hydraulics of Culverts: Concrete & Metal Arch
26 12/86 (R) 04/91 Hydraulics Capacity of Precast Concrete Boxes
27 12/86 (R) 12/90 Hydraulics of Culverts: Concrete Boxes 3' - 6'
28 12/86 (R) 12/90 Hydraulics of Culverts: Concrete Boxes 7' - 10'
33 04/78 05/89 Precast Concrete Box Sect Partial Flow Condition
34 05/87 (R) 05/87 Hydraulics of Culverts: Concrete Boxes 11' - 12'
Installation
21 10/80 (R) 12/88 Curved Alignment
Miscellaneous
12 07/69 09/90 Precast Concrete Manholes
30 10/92 (R) 10/92 Flotation of Circular Concrete Pipe
39 12/86 11/87 Low Pressure Air Testing of Sewers
41 11/96 11/96 Manhole Flotation
(R) Revised

You might also like