You are on page 1of 36

Interpreting

SNT-TC-1A
ninth edition

Interpretations from 1976 through 2011.

The American Society for Nondestructive Testing


Copyright 2012 by The American Society for Nondestructive Testing.

The American Society for Nondestructive Testing, Inc. (ASNT) is not responsible for the authenticity or accuracy of information
herein. Published opinions and statements do not necessarily reflect the opinion of ASNT. Products or services that are advertised or
mentioned do not carry the endorsement or recommendation of ASNT.

No part of this publication may be reproduced or transmitted in any form, by means electronic or mechanical including photocopying,
recording or otherwise, without the expressed prior written permission of The American Society for Nondestructive Testing, Inc.

IRRSP, NDT Handbook, The NDT Technician and www.asnt.org are trademarks of The American Society for Nondestructive Testing,
Inc. ACCP, ASNT, Level III Study Guide, Materials Evaluation, Nondestructive Testing Handbook, Research in Nondestructive
Evaluation and RNDE are registered trademarks of The American Society for Nondestructive Testing, Inc.

This document was originally prepared for ASNTs Technical and Education Council by the SNT-TC-1A Interpretation Panel.
Responses to inquiries were first published in Ready Reference (February) issues of the Societys monthly journal Materials
Evaluation and have been edited here only as needed to maintain consistency in language and format.

Inquiries are numbered to include the year of the inquiry and always refer to the edition of
SNT-TC-1A in effect in that year, unless otherwise stated in the question. SNT-TC-1A was published in these years: 1968, 1975, 1980, 1984,
1988, 1992, 1996, 2001, 2007 (2006 edition), and 2011.

first printing 1996


second printing, with revisions 02/02
third printing, with revisions 03/03
fourth printing 08/03
fifth printing 05/06
sixth printing, with revisions 06/07
seventh printing, with revisions 02/08
eighth printing, with revisions 03/09
ninth printing, with revisions 03/10
10th printing, with revision 02/11
11th printing with revision 02/12

Errata, if available for this printing, may be obtained from ASNTs website, www.asnt.org.

ISBN-13: 978-1-57117-103-0

Printed in the United States of America

Published by: The American Society for Nondestructive Testing, Inc.


1711 Arlingate Lane
Columbus, OH 43228-0518
www.asnt.org

Edited by: Cynthia M. Leeman, Educational Materials Supervisor

Tim Jones, Senior Manager of Publications

ASNT Mission Statement:


ASNT exists to create a safer world by promoting the profession and technologies of nondestructive testing.

ii Interpreting SNT-TC-1A
Introduction intent and are subject to the statement of
Scope in each edition of SNT-TC-1A,
information and, if possible, asked in such
a manner that a yes or no (with a short
The SNT-TC-1A Interpretation Panel such as the 1980 edition, Paragraph 1.4, It explanation) would be an acceptable reply.
was established to respond to written is recognized that these guidelines may not The background explanation for the
inquiries about Recommended Practice be appropriate for certain employers question can be prepared separately from
No. SNT-TC-1A, Personnel Qualification circumstances and/or applications. In the question. It should state the purpose of
and Certification in Nondestructive developing a written practice as required the inquiry, which could be to obtain a
Testing. in Paragraph 5, the employer shall review clarification of the documents
Following are responses by the panel to the detailed recommendations presented recommendations or the intent of ASNTs
inquiries submitted from 1976 through herein and shall modify them as necessary Technical and Education Council; provide
2011. The responses clarify the intent of to meet particular needs. concisely the information needed for the
ASNTs Technical and Education Council panels understanding of the inquiry and
and the recommendations of SNT-TC-1A. include references to applicable paragraphs
Inquiries are numbered to include the Guidelines for Inquiry of SNT-TC-1A, including date of edition.
year of the inquiry and always refer to the Preparation Sometimes it helps the panel members
edition of SNT-TC-1A in effect in that year, understanding if the inquirer includesset
unless otherwise stated in the question. The following guidelines for preparing
aside from the body of the lettera
New editions of SNT-TC-1A were an inquiry to the panel will expedite
proposed response at the end of the
published in these years: 1968, 1975, consideration and response to the inquirer.
letter. Do not solicit from the panel an
1980, 1984, 1988, 1992, 1996, 2001, 2007 Each inquiry should be limited to a single
opinion or interpretation of an employers
(2006 edition), and 2011. recommendation of SNT-TC-1A. Inquiries
written practice, nor of another partys
Users of SNT-TC-1A are reminded that concerning multiple recommendations of
opinion of an employers written practice.
the document is intended as a guideline for SNT-TC-1A or unrelated subjects may be
Inquiries should be sent to the attention
employers to establish their own written returned for further clarification.
of the Chair of the SNT-TC-1A
practices for the qualification and The specific question to be answered by
Interpretation Panel, ASNT, Technical
certification of their nondestructive testing the panel should be distinctly set apart
Services Department, 1711 Arlingate Lane,
personnel. from the body of the letter and in a
PO Box 28518, Columbus, OH
The responses of the SNT-TC-1A condensed, precise, question format,
43228-0518.
Interpretation Panel are clarifications of omitting superfluous background

Interpreting SNT-TC-1A iii


Inquiry 76-1 Paragraph 4.3(a) of the 1975 edition of this
document be the same as the Level I
Inquiry 77-1
Table 6.2.1A contains the statement individual described in the SNT-TC-1A 1. Is it intended that the 1975 edition
Credit for experience may be gained (1968 edition) Paragraph 4.1(a) with both of SNT-TC-1A including all
simultaneously in two or more disciplines. having the same capabilities? recommendations therein completely
The candidate must spend at least replace prior editions of
25 percent of his work time on each Response SNT-TC-1A?
discipline for which experience is being 2. Is it intended that personnel
claimed. Our question is this: Over what Yes. The changes in wording between qualified and certified as
time period does the term the 1975 and the 1968 versions of recommended in the 1975 edition of
simultaneously apply? SNT-TC-1A, insofar as the duties and SNT-TC-1A be considered equivalent
capabilities of Level I personnel are to those qualified and certified as
Response concerned, were intended only to clarify recommended in previous editions
the intent of the document. None of these of SNT-TC-1A?
The employers written practice should changes in wording were intended as
specify the time period over which substantive changes.
simultaneous experience shall be credited. Response
The answer is yes to both parts of the
Inquiry 76-2 Inquiry 76-4 inquiry.
1. For requalification of Level I and II Paragraph 1.1 of SNT-TC-1A refers to
NDT personnel, does Paragraph individuals who perform, witness,
monitor or evaluate nondestructive tests.
Inquiry 77-3
6.2.1 imply that you must keep With respect to Paragraphs 9.4 and 9.5
continuous records by the hour Is it intended that individuals whose
principal functions are to witness, monitor of SNT-TC-1A:
showing that the individual has 1. Is it the intent to restrict an employer
continuously spent at least or evaluate nondestructive tests be
qualified in the same manner as those to engage only Level III services
25 percent of his work time working from an outside agency or may
in each method to which qualified? whose principal function is to perform
nondestructive tests? Level I and Level II services also be
2. Because of the 25 percent used in the utilized?
note to Table 6.2.1A, it has been 2. Is it intended in Paragraph 9.5 that
implied that an individual at Response
an employer may subcontract
maximum could be qualified in only It is intended that the employer training, examination and
four methods and this would be true designate through the written practice as certification for all levels, provided
only if he could show that exactly recommended in Paragraph 5 specific jobs the employers audit results are
25 percent of his work time was that require knowledge of the technical found to be satisfactory?
spent in each of four methods. Was principles of nondestructive testing. The 3. Paragraph 9.1 states that the
this the intent of SNT-TC-1A? employer should test the statement of certification of all levels is the
Paragraph 1.1, ... personnel whose responsibility of the employer.
Response specific jobs require appropriate Paragraph 9.5 recognizes the use of
1. No. Table 6.2.1A applies only to knowledge of the technical principles outside certification services. May
initial experience required for underlying the nondestructive tests they an employer subcontract
qualification; it is not applicable to perform, witness, monitor or evaluate, nondestructive testing to an outside
requalification. against the specific job elements of the organization utilizing that
2. No. The candidate may be qualified personnel in question in order to establish organizations certifications for
in as many methods as desired. The whether or not the specific job requires Levels I, II and III, provided the
25 percent work time experience knowledge of nondestructive testing. results of the employers audit of
only applies to the work time that organization are satisfactory?
experience required for initial Inquiry 76-5 Must the employer personally certify
qualification in each level for each NDT personnel or may he accept the
method. The 25 percent is not In accordance with SNT-TC-1A (1975 outside organizations certification?
applicable and is not required for the edition), may a Level I NDT person who
individual to remain qualified in a has been trained, qualified and certified in Response
particular method at a specific accordance with SNT-TC-1A (1975
edition) be the sole person to perform, 1. It is intended that Level III services
qualification level. may be obtained from an outside
evaluate and sign for final acceptance of
NDT examinations in accordance with agency for the purpose of training
General Comments and examining NDT personnel. It is
written procedures and acceptance
Paragraph 6.2.1, like the rest of standards with occasional surveillance and beyond the scope of SNT-TC-1A to
SNT-TC-1A, is only a guide. The guidance from a Level II or III? recommend whether or not outside
employers written practice should detail inspection services should be
all such requirements, which may differ Response obtained. It is definitely not intended
from the recommendations of that the employer be restricted from
Paragraph 6.2.1. Yes. The intent in SNT-TC-1A is that utilizing any outside NDT services.
the Level I person may perform the above 2. The intent of Paragraph 9.5 is to
functions provided they are in accordance emphasize the responsibility of the
Inquiry 76-3 with written procedures and so employer to assure by audit that any
Is it the intent of SNT-TC-1A that the documented in the employers written and all parts of purchased services
Level I NDT persons described in practice. attendant to qualification and

Interpreting SNT-TC-1A 1
certification of NDT personnel are certification program in accordance with Response
within the same guidelines that the this document shall be considered as Published in Materials Evaluation,
employer himself would follow in satisfying the criteria of Paragraph 6.2.1
May 1978, page 21, is the ASNT
accordance with his written practice. and 6.3. If documentation was not
Position Paper on the Use of SNT-TC-1A
3. The intent underlying Paragraph 9.1 produced during such prior experience, an
and the ASNT Level III Certification
is fundamental. When outside affidavit or other suitable testimony
Level III services are used for the regarding such experience may be Program. Under the heading
purpose of qualifying and certifying evaluated by the employer to aid in Certification Options is the following:
personnel, it is intended that the determining equivalence. This response [The employer can] Incorporate
employer utilizing such services be applies to the 1975 edition and all prior into his written practice acceptance
responsible for assuring that those editions of SNT-TC-1A. See Inquiry 77-1. of ASNT Level III certification as
services are properly performed and permitted in 9.4 of SNT-TC-1A for
audited. Whether or not the meeting any or all examination
employer uses outside Level III Inquiry 77-5 requirements of 8.5.3 (general,
services for training and examining With reference to Paragraph 8.5 of the specific and practical) and
his NDT personnel, the total 1975 edition of SNT-TC-1A, is it intended assigning grading weight factors
responsibility for certification of all to limit the written specific examination to based on satisfactory performance,
levels rests with the employer of the a closed book examination, without access in accordance with 8.6.3 and 8.6.4.
individuals. to codes, specifications and/or
SNT-TC-1A only provides guidelines procedures?
for qualification and certification of NDT
Inquiry 77-10
personnel. Outside services referred to in Response What is the intent regarding employers
Paragraph 9 are those intended to be used attempts to verify an individuals
It is intended that codes, specifications
by an employer only for the purposes of experience and performance with past
and/or procedures are necessary data
training, examining or otherwise employers in order to maintain the
under Paragraph 8.5 of the 1975 edition of
qualifying individuals directly employed documentation recommended in
SNT-TC-1A, provided that examination
by the employer. Paragraph 9.6.1?
questions are asked that require reference
When the performance of NDT is
to such data and that such data cannot be
subcontracted to an outside organization Response
used to answer questions related to other
and the outside organization is the direct The specific documentation to be
closed book portions of the examination.
employer of the individual performing furnished by new employees and past
NDT, the outside organization is the employers and the means for obtaining
employer in terms of SNT-TC-1A. Inquiry 77-6 documentation is referenced in
Whether the outside organization is Paragraphs 9.6 and 10.2 of SNT-TC-1A.
properly qualifying and certifying its NDT 1. Is it the intent of SNT-TC-1A that
Level I, II and III individuals Details should be included in the
personnel can only be determined by the employers written practice.
purchaser of such outside services and certified to the recommendations of
how such determination is made is a the 1968 edition meet the
recommendations for certification in General Comments
contractual matter between the purchaser
and the outside organization. the 1975 edition? As published above and in Materials
2. If certification is transferred from Evaluation, October 1977, in response to
the 1968 edition to the 1975 edition Inquiry 77-4, If documentation was not
Inquiry 77-4 recommendations, which produced during ... prior experience, an
recommendations prevail regarding affidavit or other suitable testimony
May the experience requirements
recertification? regarding such experience may be
expressed as certified NDT Level II in
Paragraph 6.3.1(b), (c) and (d) of the 1975 evaluated by the employer ... While
Response Inquiry 77-4 was related to a somewhat
edition of SNT-TC-1A be considered to
include experience gained in an 1. It is intended that individuals different matter, the intent behind the
assignment comparable to that of an NDT certified according to the response applies equally to this inquiry
Level II [as stated in Paragraph 6.3.2(a)] recommendations of earlier editions (77-10).
in determining the prerequisite of SNT-TC-1A meet the
requirements of a candidate for recommendations for certification in Inquiry 77-12
certification as a Level III? If so, may this the 1975 edition.
acceptance of experience in an 2. The 1975 edition recommendations 1. Is it intended that an employer may
assignment comparable to be extended to prevail regarding recertification. use more than one outside agency
include similar subparagraphs under See also Inquiry 78-2. for providing Level III services?
Paragraph 6.2.5 of the earlier editions of 2. Is it intended that an employer may
SNT-TC-1A? use Level III individuals in his direct
Inquiry 77-8 employment and also use an outside
Response Level III personnel certified by ASNT agency for Level III services?
do not receive examination grades. 3. Is it intended that certification
Paragraph 6.2 of the 1975 edition of examinations may be administered
SNT-TC-1A states, Documented training Paragraph 8.6 of SNT-TC-1A recommends
arriving at a composite grade. How can without direct supervision and
and/or experience gained in positions and monitoring?
activities equivalent to those of Level II or this be accomplished since ASNT only
Level III prior to establishment of the supplies examination results in terms of
employers written practice and a pass or fail?

2 Interpreting SNT-TC-1A
Response additional training and reexamination 2. It is intended that an individual who
1. There is no intent to restrict the required to upgrade these individuals? has neither worked in the capacity to
number of outside agencies from which previously certified in the
which an employer could use Response past six months nor is being
Level III services. It is the intent that individuals certified recertified within six months should
2. Yes, both the above and this in accordance with the recommendations have additional training and
situation may be used under of the 1968 edition can be automatically experience prior to recertification.
circumstances as described in the certified to the recommendations of the The employers written practice
employers written practice. 1975 edition without additional training or should detail such provisions.
3. It is not intended that unsupervised experience. For recertification, it is
examinations be administered. intended that individuals should meet the Inquiry 78-6
guidelines of the 1975 edition as reflected
in the employers written practice. Is it the intent of SNT-TC-1A to
Inquiry 77-13 recommend that the percented weight
Regarding Paragraph 8.5.3(a) of factors of Paragraph 8.6.3 may be applied
SNT-TC-1A, is it intended that the 30
Inquiry 78-3 based upon differing job requirements of
questions from the NDT Level II With reference to the note in Table individual candidates or should they be
questions for other applicable NDT 6.2.1A, Credit for experience may be applied equally to all individuals within a
methods be selected from and represent particular level?
gained simultaneously in two or more
every test discipline listed in disciplines. The candidate must spend at
Paragraph 8.5.2? Response
least 25 percent of his work time on each
discipline for which experience is being Percentile weight factors should be
Response claimed, is it intended that an individual within the ranges shown in SNT-TC-1A,
No, it is intended that the examiner being qualified in only one method could Paragraph 8.6.3. The specific percentile
select the questions applicable or obtain the work time experience in weight factors used should be clearly
appropriate to the product requirements of 25 percent of the times tabulated in Table stated in the employers written practice
the particular case. This is a specific 6.2.1A? and should be based on the particular
recommendation for examining Level IIIs needs of the employer. The same weight
and in no manner conflicts with the Response factors should be used uniformly for all
Level III qualifications of Paragraph the employers personnel seeking
No, an individual being qualified in certification for given job requirements.
4.3(c) of SNT-TC-1A. only one method should spend at least However, the employer may change or
25 percent of his work time in that modify the weight factors for different job
Inquiry 78-1 method and should obtain the total work requirements within a single level
time experience as recommended in provided they remain within the ranges
If a Level II examination is consecutive months as though the recommended in Paragraph 8.6.3.
administered to a Level I individual, is remainder of his work time was spent in
there a need, when that individual is qualifying for other NDT methods
eligible for Level II certification, to simultaneously. Inquiry 78-7
readminister the same Level II
examination provided that all other 1. Should personnel who operate
criteria, for example, education, training Inquiry 78-4 digital thickness measurement
and experience, have been satisfied? equipment be qualified and
1. Regarding Paragraph 10.2 of certified?
SNT-TC-1A, does ... based on 2. To what level should such personnel
Response examination ... refer to be certified?
It is not intended that the individual examinations administered during 3. Does ASNT anticipate a change in
should be reexamined, provided the prior employment or does it refer to SNT-TC-1A that would provide
original Level II examination was passed new examinations to be specific recommendations for
and all applicable requirements of the administered by the new employer? qualifying and certifying such
employers written practice have been met 2. An individual can provide evidence personnel?
according to Paragraph 8.1 of SNT-TC-1A. of prior certification per
Paragraph 10.2(a), but does not meet Response
either Paragraphs 10.2(b) or 10.2(c)
Inquiry 78-2 which recommend that the 1. Whether any NDT personnel should
individual was working in the be certified depends solely upon the
See Inquiry 77-6, as published above
capacity to which he had been needs of the employer and the
and in Materials Evaluation, October
certified and is being recertified requirements of the employers
1977. In order to clarify the response, is it
within six months of his termination. customers or clientele.
intended that Level I, II and III
What should be the basis of 2. Likewise, the level to which
individuals who have been certified to the
qualification for such an individual? personnel should be certified
recommendation of the 1968 edition
depends upon the same factors as in
automatically meet the recommendations
Response [1.] above. Note that Paragraph 4.1
for certification in the 1975 edition?
of SNT-TC-1A provides for
Since the training hours were increased 1. It is intended that the examination subdivision within the levels as
in the 1975 edition for certain level and referred to in Paragraph 10.2 be needed.
discipline combinations above those administered by the new employer. 3. Paragraph 1.4 and Paragraph 4.1 of
recommended in the 1968 edition, is
SNT-TC-1A are intended to provide

Interpreting SNT-TC-1A 3
the employer with adequate the original three-year period of 2. Regarding Paragraph 8.2(a2), is it
flexibility to accommodate a variety certification in accordance with intended that the statement,
of special needs as documented in Paragraph 9.7? ... as demonstrated by the practical
the written practice. While the examinations or test performance,
recommended training course Response refers to the practical examination of
outline of SNT-TC-1A does not 1. The provisions of Paragraph 10.2 Paragraph 8.2(d) or does it refer to a
specifically address digital thickness apply only to a new employer. For special standardized eye test for
measurement, the principles of this part of the inquiry, the color vision?
pulse-echo techniques are those provisions of Paragraph 9.7.3 would
involved. The training course outline prevail. Response
does not provide for instruction in 2. For this part of the inquiry, the 1. It is intended that Level III
the employers specific equipment receiving employer would be personnel be allowed to administer
uses and, as with the remainder of considered a new employer and the the near-distance vision acuity
SNT-TC-1A, the training course provisions of Paragraph 10.2 would examination using the Jaeger chart.
outline should be modified, if apply. If, however, the employee in However, if the employer elects to
necessary, to meet employers question was previously employed use other methods of vision
specific needs. by the receiving employer, examination or the employer
Paragraph 9.7.3 would prevail. requires additional physical
Inquiry 78-9 requirements as referred to in
General Comments Paragraph 8.2(a3), it may be
Is it intended that personnel currently necessary to use personnel with
certified as NDT Level III within the The principle behind evidence of
continuing satisfactory performance in other specialized qualifications to
guidelines of SNT-TC-1A who also administer examinations for such
regularly perform Level II functions be Paragraph 9.7.1(a) applies to employees
originally certified by, and in continuous additional requirements. The
qualified as recommended in employer should include details of
Paragraphs 8.2, 8.5.2, 8.6 and 9.7? employment of, one employer. It is not
envisioned that a new employer should specific physical requirements and
prudently accept evidence of continuing the qualifications required of
Response examiners in the written practice.
satisfactory performance from a previous
It is the opinion of the Interpretation employer. Note that Paragraph 10.2 2. It is intended that the practical
Panel that personnel currently certified as recommends recertification by examination referred to in
Level III may regularly perform Level II examination of an employee by a new Paragraph 8.2(a2) is that of
functions without specifically being employer even if the conditions of Paragraph 8.2(d) and that such
qualified as Level II as recommended in 10.2(a), 10.2(b) and 10.2(c) are met to the practical examination include
Paragraph 8.2, 8.5.2 and 8.6 of new employers satisfaction. The checkpoints as appropriate to verify
SNT-TC-1A. However, as recommended in employers rules covering the duration of that the candidates color vision
Paragraph 9.7, all levels should be interrupted service (Paragraph 9.7.3) capabilities are adequate to satisfy
periodically recertified. should bear a reasonable relationship to the specific needs imposed by the
the recommendations in Paragraph 10.2. NDT method in question, the
General Comments However, in the case of interrupted employers test equipment,
service, the employer has direct procedures and products.
Implicit in the definitions of Levels I, II
and III as outlined in Paragraphs 4.3(a), knowledge of the employees prior
4.3(b) and 4.3(c) is the concept that the performance and can best judge the need Inquiry 79-1
qualifications for Level III equal and for reexamination as a function of
exceed those of Level II. The employer duration of interrupted service. In maintaining records, if an individual
must be satisfied with the proficiency of is working simultaneously in more than
any individual at any level to handle work one method, should the records reflect the
tasks. SNT-TC-1A is not intended for use
Inquiry 78-11 total time spent for each method or should
to determine an individuals proficiency. It 1. Regarding Paragraph 8.2(a1) of the time be divided proportionately for
is intended as a guideline to establish SNT-TC-1A, is it intended that the each of the methods? For example, if an
qualifications. personnel referred to in the individual spent 50 percent of his time on
statement, The examination shall ultrasonic testing and 50 percent of his
be administered by qualified time on radiographic testing for a period
Inquiry 78-10 personnel ..., be qualified medical of nine months, should the record show
personnel or may a certified experience in ultrasonic testing of four
1. When an employee returns to work
Level III person administer the and one-half months or nine months?
for a former employer where he was
certified, may the employees near-distance vision acuity
examination when a standard Jaeger Response
certification(s) be reinstated without
examination if the provisions of test chart is used? It would appear It is intended that the employers
Paragraphs 10.2(b) and 10.2(c) are that the qualifications necessary to written practice should include details of
met? administer such examinations would maintaining records. It is intended that
2. If an employee has been only include the capability to read, records should reflect the facts of each
continuously working for another to identify the Jaeger chart and the individuals work time with regard to the
employer certified in the same appropriate parts thereof and to be amount of time spent on each method and
capacities, may his certification(s) able to measure and maintain the the periods of time during which the work
be reinstated for the remainder of 12 in. required reading distance. was performed.

4 Interpreting SNT-TC-1A
Inquiry 79-2 Response Response

Since NDT Level III general 1. The reading card intended to be It is not intended that laboratory
examination questions in some methods considered standard is currently experience in an educational program be
are available from ASNT (Questions and available from ASNT and was directly applied to the work time
Answers for Qualifying NDT Level III previously supplied by Bausch & experience. Laboratory experience is not
Personnel, October 1977), is it intended Lomb. Bausch & Lomb no longer necessarily applicable to the employers
that the Level III questions referred to in supplies such cards, but those product or to the specific codes, standards
Paragraphs 8.4 and 8.5.3(a) be selected bearing the title, Reading Card or specifications in use. However, in
from those published by ASNT? (Metric), with the notation at the recognition of the benefits accruing from
bottom of the card reading, The laboratory experience, the employer may
Response above letters are Snellen sizes at the include such consideration for adjustment
designated distance in decimeters, to the work experience in his written
It is intended that the recommended with Jaeger notations at right, as practice. Should the employer decide to
30 questions devised by the examiner for previously supplied by Bausch & do so, he should thoroughly evaluate the
the appropriate method [Paragraph Lomb are equivalent to the card curriculum to determine its applicability.
8.5.3(a)] be devised or selected as currently available from ASNT.
appropriate to the degree required by the Other cards bearing equivalent type
employers written practice. As with all size and body are also intended to be Inquiry 80-2
questions and answers provided by ASNT, used. In reference to the practical examina-
they are suggested as guidelines and 2. The intent in Paragraph 8.2(a1) was tion, there are several approaches that may
supplied as an aid to employers in to recommend a minimum distance. be taken. For example, grades on check
preparing examinations. It is intended that The employers written practice points could be given as 1 (correct) or 0
the provisions of Paragraph 8.4 be should state the near-distance vision (incorrect) or could be given in a graduat-
superseded when questions of a character acuity requirements for the ed fashion, say 0 to 5, depending on the
unique to Level III qualifications as particular circumstances of the correctness and efficiency of the applica-
delineated in Paragraph 4.3(c) are devised employer. tion. Which approach is correct? Could a
or selected by the employer for use in the questionnaire for which written answers
Level III general examination. The would be prepared as an alternative
additional 30 questions from Level II Inquiry 79-13 method of grading be used?
questions for other applicable NDT If an employee performs NDT to
methods as recommended in Paragraph multiple codes, specifications and Response
8.5.3(a) are intended to be selected from acceptance standards, is it necessary to
methods other than that for which the Please refer to Paragraphs 8.5.1(c) and
include questions relating to each code, 9.6.1(f). Either of the proposed grading
candidate is being examined. It is intended specification or acceptance standard in
that the employer use such questions to methods is permissible depending on the
this Specific examination? needs of the employer. Other approaches
determine that the candidate has sufficient Paragraph 9.6.1(c) requires records of
knowledge of other NDT methods that may also be taken. The approach which
educational background to be included in meets the needs of the employer should
might be applicable to the employers personnel records. Is information supplied
particular circumstances. For example, it be described in his written practice and
by the employee (i.e., such as a rsum or followed for the practical examination.
could be appropriate that a candidate employment application) satisfactory
being examined for Level III qualification The last technique proposing a question-
evidence of educational accomplishments naire for which written answers would be
in a particular method be required to or is conclusive evidence (i.e., such as a
demonstrate basic knowledge in one or prepared would fall more appropriately
copy of a diploma or transcript) required under the Specific examination category.
more other methods in order to designate for verification?
the particular test method and technique to
be used. See Paragraph 4.3(c). Response Inquiry 80-3
It is the intent of Paragraph 8.2(c2) that A candidate spends 50 percent of his
Inquiry 79-4 the Specific examination cover all codes, time performing radiography, 25 percent
1. In Paragraph 8.2(a1), reference is specifications and acceptance standards performing magnetic particle
made to a standard Jaeger test applicable to the employees activities. examinations and the remaining
chart. Of several reading cards See also Inquiry 77-4 and 25 percent performing liquid penetrant
available, which is considered Inquiry 77-10. examinations. At the end of a one-month
standard? period, assuming a 144-hour month, is
Method A or Method B a correct
2. In Paragraph 8.2(a1), the Inquiries 79-14 and 79-15 computation of working time experience
recommended distance for reading
Jaeger Number 2 letters is not less Is it intended per SNT-TC-1A (1975 for certification to a Level I rating?
than 12 in. (30.5 cm). On the edition) that the time spent in a laboratory Method A: The candidate claims work
reading card currently available exercise during a long term NDT course time experience of 144 hours for each of
from ASNT, the designated be considered the only qualifying work the three methods.
distance in decimeters for J2 letters time experience? Method B: The candidate claims work
is 5 dm or approximately 19.7 in. Is May the laboratory time be given any time experience of 72, 36 and 36 hours
it intended that the near-distance credit at all as work time experience to for radiography, magnetic particle and
vision acuity requirements be satisfy all the requirements in liquid penetrant, respectively.
reduced by such a significant factor? Table 6.2.1A?

Interpreting SNT-TC-1A 5
Response Response Inquiry 80-9
These questions have been addressed 1. This inquiry is similar to Is there an acceptable method by
in Inquiries 76-1, 76-2 and 78-3, which Inquiry 76-4 which was answered which a Level III may be certified by a
were published above and in Materials above and in the October 1978 issue new employer on the basis of Level III
Evaluation in October 1977 and October of Materials Evaluation. It must certification examinations administered
1978. As further clarification, the method again be emphasized that by the former employer without
described in Method A is that intended SNT-TC-1A is a guideline to aid an examination?
by the document. In other words, the employer in certifying his employees
examiner may claim full-time for all the and the guidelines combined in that Response
NDT methods in which he works document should be modified to
simultaneously. It is not intended he meet the employer needs. As outlined in Paragraph 8.5.4, an
claim time for work hours spent in work 2. It is the intent of this statement that employer may waive examination for an
other than nondestructive testing. a candidate may take credit for work NDT Level III based on the candidates
performed in two methods demonstrated and documented ability,
simultaneously because of the achievement, experience and education as
Inquiry 80-4 knowledge interchange factor defined in Paragraph 4.3(c) and 6.3.
NDT examiners in our employ who believed to be present in such However, if the new employer desires that
perform examinations using liquid activities. It is not intended that an the certification be based on examination,
penetrant use only the visible dye, solvent examiner certified in one method then the employer must reexamine the
removable, penetrant technique. Since our could at some later time reduce the candidate or obtain copies of the
examiners do not have need to be requirements for certification in examinations taken by the candidate at the
qualified in the other liquid penetrant another method except as defined in previous employer. This step is necessary
techniques, is it permissible to modify the the employers written practice. to ensure the quality of the examination
number of general and specific questions and to meet the documentation needs of
as well as the hours of training and work Paragraph 9.6.1(f).
experience to satisfy requirements of
Inquiry 80-7
SNT-TC-1A for Level I and Level II
examiners?
In the NDT Level II practical
examination, 8.5.2(c), is it intended that
Inquiry 80-12
the NDT Level II candidate demonstrate 1. If a candidate does not spend
Response proficiency in all phases of the NDT 25 percent of his time in the
operation (i.e., set up, calibration, method in a given period, e.g., one
Please refer to Inquiry 76-2, published month, can he accumulate one
above and in Materials Evaluation in inspection and interpretation)?
months credit over a longer period,
October 1977 and Inquiry 77-13 published e.g., two months and claim one
above and in Materials Evaluation in Response
months experience?
October 1978. It is the intent that Yes, it is intended that the Level II 2. What constitutes an NDT-related
SNT-TC-1A is a recommended practice demonstrate proficiency in all phases of activity that may be identified in
and that it is a guideline which should be the operation for which the candidate is the employers written practice?
modified by the employer as necessary to being certified. The employers written What percentage of time may be
meet his particular needs. The employer practice should define the duties and NDT related?
should determine his needs, determine the needed knowledge. 3. Can work experience prior to and in
necessary qualifications of his examiners excess of the Level I requirements
to meet those needs and describe those in
his written practice. Inquiry 80-8 be applied to Level II experience
requirements?
1. May an employer deviate from the 4. May documented experience at a
guidelines to meet his specific
Inquiry 80-6 needs?
level equivalent to NDT Level II in
a company without a certification
1. How may we qualify supervisory 2. Is our companys specific written program be used by a new
personnel in accordance with practice acceptable? employer to fulfill experience
SNT-TC-1A? Supervisory personnel requirements for Level II?
would include quality control Response
engineers in plants doing 1. Yes, in accordance with Response
surveillance-type inspection. Paragraph 1.4 of SNT-TC-1A, the
2. Table 6.2.1A for SNT-TC-1A 1. No, the intent of the note to Table
employer should modify the 6.2.1A (6.3.1) is that work time
provides: credit for experience may guidelines to meet his needs.
be gained simultaneously in two or experience claimed for a specific
2. It is against ASNT policy to judge period should be accumulated in
more disciplines. The candidate the applicability of company
must spend at least 25 percent of that period. For example, to claim
documents. As a general comment, one month work time experience,
this work time on each discipline for it is the employers prerogative to
which experience is being claimed. the candidate should spend at least
establish his criteria for 44 hours (one fourth of 175) in the
Does this statement mean (as it certification. It is then his
regards Level I PT) that if the method and the remaining work
customers prerogative to accept or time (75 percent) of that month in
candidate is already a qualified reject those criteria.
Level I or Level II radiographer, the NDT-related activities.
one month work experience can be 2. As stated in the note to Table 6.3.1
reduced to 44 hours? (1980 edition), the employer should

6 Interpreting SNT-TC-1A
define NDT-related activities. It is capability of distinguishing and own employer, not the
also intended that all work time differentiating contrast between colors on aforementioned Level III.
experience claimed should be in an annual basis or only upon certification
NDT or its related activities. and/or recertification?
3. Note (1) to Table 6.3.1 (1980 Inquiry 81-12
edition) and Table 6.2.1A (1975 Response Paragraph 9.6.1(f) (1975 edition)
edition) indicate that the total NDT The individual should demonstrate states that qualification records should
experience of the candidate may be this capability upon original certification include copies of current examinations
applied to the requirements for and upon recertification by practical and of grades for all previous
Level II. examination or work performance. examinations and ... Does the phrase
4. Yes, provided the experience is Normally, recertification occurs at grades for all previous examinations
documented to the requirements of three-year intervals. imply grades for examinations by the
the new employers written practice present employer and/or previous
and the candidate passes the employers and outside agencies?
necessary examinations. Inquiry 81-3
The ASNT examinations for Level III Response
General Comments
are referred to as General and Paragraph 9.6.1(f) (1975 edition)
Please note that experience required Practical. In the 1980 edition, these are applies to examinations administered by
for Level II includes work at both trainee Basic and Method. May I assume the present employer.
and Level I levels. Work experience this is a change in terminology and that
claimed for Level II should meet the the examinations are equivalent?
experience required at these levels. Inquiry 81-13
Response Does on-the-job training in lieu of
Inquiry 80-14 The ASNT Level III examinations are classroom training satisfy the requirement
titled Basic and Method as are the for organized training?
There are certain differences in the designated examinations in SNT-TC-1A
1975 and 1980 editions of SNT-TC-1A. Is (1980 edition). It is intended that the Response
it the intent that individuals qualified to ASNT Level III examinations satisfy the Paragraph 7.1 (1980 edition) states that
the 1975 edition be certified as qualified General and Practical examinations the personnel should complete sufficient
to the 1980 edition without reexamination of SNT-TC-1A (1975 edition). organized training to become thoroughly
(where examinations have been used as
familiar with the principles and practices
the basis for qualification) when an
of the specified test method ... It is
organization chooses to upgrade their Inquiry 81-5 intended that the training be organized
written practice to the 1980 edition?
Do the requirements identified in into a definite training program although
Table 6.2.1A (1975 edition) include (a) the form of that training is not specified.
Response
required performance of the test method
Yes, it is the intent that individuals by personnel for certification or (b)
certified to the 1975 edition, whether by personnel are to be employed where the Inquiry 81-15
examination or by waiver in accordance test method is being utilized? Paragraph 8.1.1.2 states, The
with Paragraph 8.5.4 (1975 edition), are examination should demonstrate the
automatically certified to the 1980 edition Response capability of distinguishing and
when the employer chooses to upgrade his differentiating contrast between colors
The intent of SNT-TC-1A is clear.
written practice to the 1980 edition. used in the method. Does the Ishihara
Actual performance of work in the
Subsequent recertifications should be to color chart satisfy this requirement?
method is required for that time to be
the guidelines of the later edition.
claimed as work experience.
Response
Inquiry 80-15 Inquiry 81-9 Any means used to determine the
individuals capabilities of color
What is the definition of annual as
1. May the president of an NDT differentiation and distinguishing:
used in SNT-TC-1A (1980 edition),
company appoint himself as a (1) which actually accomplishes the
Paragraph 8.1.1(4), The examination
Level III provided he is qualified? determination and (2) which is
should be administered on an annual
2. May a Level III qualify NDT satisfactory to the employer and its
basis?
personnel for another company? customer should fulfill this requirement.
Response
Response
The intent of this statement is that the Inquiry 81-16
1. An employer may certify any
examination should be administered Is it the intent of SNT-TC-1A that
employee as Level III provided the
every year with the interval between employers may prorate classroom training
individual has the qualifications
examinations not to exceed 12 months hour requirements for personnel with an
required by the employers written
from the month of the examination. education level between the educational
practice.
2. Yes, he may attest to the levels defined in the document?
Inquiry 81-1 qualifications of an individual in
another company. However, the
Is it the intent of Paragraph 8.2(a2) individual must be certified by his
that individuals demonstrate the

Interpreting SNT-TC-1A 7
Response (75 percent) in that period in NDT-related considerations. The employers written
Table 6.3.1 and Paragraph 6.3.2 (1980 activities? practice should designate the Level III
edition) prorate classroom training hours Example: Three months work time responsible for certification of Level I
based on education levels and experience experience credited when a total of at and II individuals and the person
for Levels I, II and III certification. least 132 hours are spent in penetrant responsible for certification of Level III
Prorating between those specified is a testing during a three-calendar-month personnel.
logical progression well within the intent period while the remaining work time
experience (75 percent) in that period is
of the 1975 and 1980 editions.
spent in NDT-related activities. Inquiry 83-1
Table 6.3.1 of SNT-TC-1A (1980
Inquiry 82-1 Response edition) specifies work time experience in
1. Does Paragraph 4.1 (1975 edition) The work time experience guidelines months. Is it acceptable for the
permit qualification and certification of Table 6.2.1(a) (1975 edition) and Table employers written practice to express
under restrictive conditions, i.e., 6.3.1 (1980 edition) are total, this time in hours based on 160 hours per
NDT Level II-R or Level II-S accumulated work time experience levels. month?
(restricted or surveillance)? In accordance with Inquiry 76-1, the
2. Do these subdivided levels employers written practice should Response
referenced in Paragraph 4.1 need to specify the time period over which It is allowable for an employer to
comply with education, training and simultaneous experience shall be credited. define the number of hours that constitute
experience requirements in a month within his written practice.
Paragraph 6 and Table 6.2.1(a)? Whether 160 hours is acceptable is a
Inquiry 82-6 contractual matter between the employer
Response SNT-TC-1A (1975 edition), Section and customer.
1. Paragraph 4.1 permits subdivision 8.5.3(a) states: General Examination
Thirty questions devised by the examiner
of the basic levels of qualification
for the appropriate method, plus 30 Inquiry 83-2
as needed to fit the employers
needs. The scope of these questions from the NDT Level II Has the intent of SNT-TC-1A been
subdivisions may be greater or less questions for other applicable NDT satisfied if the employers written
than the guidelines of SNT-TC-1A. methods, are to be answered. practice states in effect that failure to
2. Education, training and experience 1. For each NDT method, must each meet the requirements of Paragraphs
guidelines of Paragraph 6 and Table Level III general examination 10.2(b) or 10.2(c) will necessitate
6.2.1(a) should be modified as contain a minimum of 60 questions? additional training and/or experience as
appropriate to meet the needs of the 2. If Level III general examinations determined by the Level III examiner?
subdivisions in accordance with are administered in more than one
Paragraph 4.1. method, is it permissible to not Response
include the 30 Level II questions
This panel cannot comment on the
from other methods (i.e., general
adequacy of an individual written
Inquiry 82-3 examinations consist of only
practice. However, according to Inquiry
30 questions in method under
Do the passing grades for Level III 78-4, the written practice should establish
consideration) and assume that the
examinations of the 1980 edition (i.e., the basis for evaluating the amount of
requirements of Section 8.5.3(a)
80 percent composite and 70 percent additional training and/or experience
have been satisfied?
minimum on each examination) satisfy required by an individual not meeting the
the requirements of the 1975 edition (i.e., requirements of 10.2(b) or 10.2(c).
Response
90 percent and 80 percent, respectively)?
Paragraph 8.5.3 (1975 edition) states
Response that each General Examination should Inquiry 83-3
comprise 60 questions, 30 for the Is it the intent of Paragraph 8.1.4.4,
The passing grades for Level III
appropriate method and 30 NDT Level II SNT-TC-1A (1980 edition) that the
examinations in the 1975 edition are
questions for other applicable NDT individuals demonstrate the capability of
based on the use of Level II questions.
methods. distinguishing and differentiating contrast
Grades for the 1980 edition are based on
the use of Level III questions and are between colors on an annual basis or
considered to meet the guidelines of the Inquiry 82-7 may this be demonstrated upon
1975 edition. recertification?
Who within a corporation is the
employer as the term is used in Response
Inquiry 82-4 SNT-TC-1A?
Per Inquiry 81-1, it is intended that an
Table 6.3.1 (1980 edition) requires individual should demonstrate the
Response
experience in excess of one month in capability of distinguishing and
certain circumstances. May credit for one No one within the corporation is the differentiating contrast between colors
of those multimonth specific periods be employer. The employer is the upon original certification and upon
given if the candidate spends at least corporation as stated in Paragraph 2.1.5: recertification by practical examination
25 percent of the applicable period in the Employer The corporate, private or or work performance.
method and the remaining work time public entity which employs personnel
for wages, salary, fees or other

8 Interpreting SNT-TC-1A
Inquiry 83-4 company in compliance with
SNT-TC-1A in certifying NDT
self-training program. Please advise if
these materials are acceptable by ASNT
1. Can the nominated Level III personnel to its own written as a home-study course.
examiner qualify other possible practice when those people are not
Level III candidates by the employees of the company but Response
examination? are paid their wages by an outside
2. Can any Level III examiner, ASNT neither accepts nor rejects
agency that does not have an training course materials. The
nominated or not by the company, established written practice?
qualify a possible Level III acceptability of any training course is a
2. And a related question: With the contractual decision between the parties
candidate by examination? qualifying practice customarily
3. Are Level III examiners under the involved.
based on documented past
grandfathering scheme accepted by experience, would the previous
ASNT in accordance with certifications be valid when the Inquiry 83-10*
SNT-TC-1A? practitioner has moved from site to
Please interpret the 25 percent rule for
site, qualifying in accordance with
Response a trainee in one method who is also
each companys written practice
performing NDT in a method for which
1. Yes. without having been directly
he is already qualified and certified.
2. No, not unless the Level III is employed, in terms of the
nominated by the company and SNT-TC-1A definition, by any of
Response
acting as its agent. them?
3. ASNT makes no differentiation Note (2) of Table 6.3.1 in the 1980
between Level IIIs grandfathered in Response edition of SNT-TC-1A applies only to
accordance with the initial ASNT initial simultaneous certification in two
1. If the company defines with its
program and those taking the or more methods. Inquiry 78-3 states that
written practice the mechanism for
ASNT examinations. an individual seeking certification in only
certifying the individuals not
one method must meet the total work
employed directly by the company,
experience hour requirement for that
Inquiry 83-5 the answer is yes.
method even if any other work
2. It is the responsibility of the
Is the intent of Paragraphs 8.1.3.2 and performed by an individual is
employer to verify the validity of
8.3.3.2(c) of SNT-TC-1A (1980 edition) NDT-related. Therefore, based upon the
previously claimed certifications
to require recertification of personnel above information, an individual seeking
used to determine an individuals
when a new code, specification and/or to be certified and/or upgraded in only
experience in accordance with the
standard is invoked by the employer? one method must meet the total
employers written practice.
experience hour requirement shown for
Response that method in the employers written
Inquiry 83-8 practice.
The Specific examinations should *Withdrawn in June 1990. See
cover the codes, specifications and We desire to have a member of Inquiry 89-3.
standards used by an employer at the management for our NDT Level III who,
time of examination. Immediate by virtue of his or her job duties, will not
recertification of individuals based on the have worked as a Level II. Clarification Inquiry 83-11
addition of new codes, specifications or is needed relative to SNT-TC-1A (1980
1. Is it the intent of Paragraph 8.3.3 of
standards would not be required unless edition), Paragraph 6.3.2.1, 6.3.2.2 or
the 1980 edition of SNT-TC-1A that
deemed necessary by the employer. 6.3.2.3. The employee may also not have
an individual who is certified NDT
However, the examinations should be any previous experience in the particular
Level III in the RT method by
revised to reflect the new materials. discipline. The questions are:
examination including a Basic,
1. How can a person become a
Method and Specific test needs to
Level III if they have not had a
Inquiry 83-6 Level II assignment?
be administered only the Method
and Specific tests when being
Does the Ishihara Color Perception 2. What types of other experiences
certified for NDT Level III in the
Test fulfill the SNT-TC-1A (1980 edition) could be counted for the Level II
UT method?
requirements for the physical requirements?
2. Is it the intent of Paragraph 8.4.2
examination in Paragraph 3.1.1.2 as that a separate weighting schedule
applicable to radiographers? Response
may be utilized that provides
1. An individual may be given credit greater weighting values for the
Response for work assignments comparable Method and Specific tests, for the
Yes, the Ishihara Color Perception to that of an NDT Level II in the situation described in [1.] above,
Test is an accepted test to demonstrate applicable test method. than are used when the individual is
the capability of distinguishing and 2. The types of work assignments administered Basic, Method and
differentiating contrast between colors. comparable to the Level II Specific tests for NDT Level III
assignments should be defined by certification?
the employer in his written practice.
Inquiry 83-7 Response
1. In relation to the SNT-TC-1A Inquiry 83-9 1. Yes.
definition of an employer and 2. Paragraph 8.4.2 requires the
Paragraphs 5.1 and 9.1: Is a Enclosed please find the cover sheets employer to establish weight
for materials that are used in our

Interpreting SNT-TC-1A 9
factors or to use simple average the form of a written instruction compliance with Section 8,
grades that are uniformly applied to applicable to a specific calibration, Examinations.
all individuals taking the same test. specific test and specific evaluation. The 2. The credit hours should be
If your written practice does this, it written instruction must be sufficiently determined by the Level III
is within the intent of SNT-TC-1A. specific and complete to ensure that the responsible for the course as
Level I individual can make a clear reflected in the employers written
determination for acceptance. The written procedure.
Inquiry 84-1 instruction shall not permit the Level I
1. Considering the responses in ASNT individual to interpret any aspect of the
Inquiry 77-1, 78-2 and 80-14 procedure and standards not specifically Inquiry 85-1
regarding recertification, it appears defined in the written instruction. May the recommended experience for
that the correct interpretation of a given method and/or level be reduced
SNT-TC-1A should be that the for a candidate having experience and
edition applicable to certification
Inquiry 84-3 certification in another examination
by examination should be the If an employee has met the training and method?
edition in effect at the time of experience requirements for a higher level
examination. Is this interpretation of certification with a former employer Response
correct? but was not certified to that level, may a No. Table 6.3.1 (1980 edition) notes
2. Is it consistent with the intent of new employer certify the person to that (1) and (2) relate to NDT-related
SNT-TC-1A that an employers higher level without additional training activities. Also see Section 3 and
procedure for certification by or experience if all requirements of 10.2 Section 6.
examination contain wording that have been met?
the applicable year of issue (of
SNT-TC-1A) will be the latest in Response Inquiry 85-2
effect at the time of examination? Yes, provided the training and We request you to clarify whether a
experience are specifically applicable to person qualified as per the 1975 edition
Response the new employers requirements, are and renewed once in three years is
1. Yes. Any or all of the editions could documented to the requirements of the required to be requalified by conducting
be referenced in the employers new employers written practice and the Specific examination as per the 1984
written practice, depending on the candidate passes the necessary edition. We interpret that the 1984
specifications or codes to which the examinations. Reference Inquiry 80-12.4. edition is applicable for the personnel
employer must conform in his taking a qualifying examination for the
business. first time and the qualification of the
2. The key word in this question is Inquiry 84-4 persons qualified prior to August 1984 is
consistent. If consistent is 1. Can home-study (correspondence) not affected.
intended to mean compatible, the courses allow one to meet the
answer is yes. If the definition of training requirements of Response
consistent is taken to mean SNT-TC-1A? Would the course Inquiries 77-1, 77-6, 78-2 and 80-14
holding always to the same better meet SNT-TC-1A if it established the precedent in principle that
principles or practice, then the included quizzes which were an individual once certified need not
answer is that SNT-TC-1A does not mailed back to the responsible establish a new certification upon
prohibit such application of Level III agency for evaluation, publication of a revised edition of
reference in an employers written allowing the agency to offer SNT-TC-1A. This interpretation is
practice. Clearly, the tests and direction to the participant? applicable to the publication of all
examinations used by the employer 2. How many hours credit for training editions of SNT-TC-1A, past and present
for certification must reflect the received would the participant be and to future editions provided that
editions referenced in the given? Would this be determined by future editions contain no provisions to
employers written practice. the authors of the course? the contrary.
Response
Inquiry 84-2 and Inquiry 85-3*
1. Yes. A home-study or
Inquiry 85-5 correspondence course may be used 1. Paragraph 6.2.1 (1975 edition)
Is it the intent of SNT-TC-1A to allow toward satisfaction of SNT-TC-1A states, The experience factor in
a Level I NDT person to perform, recommended training provided it months is based on a normal
evaluate and accept or reject an NDT is organized as a course with 40-hour work week (175 per
examination in accordance with written sufficient quizzes to assure an month). Is it intended that the
procedures and acceptance standards understanding of the material and individual document 8 hours per
without the presence of a Level II NDT that it is specifically described in day for a full calendar month to
person at the time of evaluation or the employers written practice. obtain the 175 hours?
interpretation? Quizzes associated with a 2. May an individual be certified to
home-study or correspondence Level I in the MT method after
Response course may be used toward working one to three hours per day
A Level I individual may perform the compliance with Paragraph 7 to every day for one month while also
functions as inquired only if the written insure comprehension of training performing regular duties as a
procedure and acceptance standards are in information, but not toward Level II in the PT method?

10 Interpreting SNT-TC-1A
3. May time spent in formal training establishing the certification date based Therefore, in strict conformance with
beyond minimum requirements be on all qualifications being met regardless SNT-TC-1A (1975 edition), a practical
applied to experience? of the final order of completion? examination is required. Together with
Specific examination, the grades may
Response Response constitute from 0.4 to 0.6 percentile
1. No. See Inquiry 80-12: The SNT-TC-1A does not recommend a weight factor. There is no
employers written practice should sequence for completing the various recommended distribution for weight
specify the time period over which requirements for certification. The factors between the Specific and
simultaneous experience should be employers written practice shall cover Practical Examination. The employer
credited. See also Inquiry 76-1. all phases of certification, but the written may choose any distribution. The
2. Yes, if the working hours in the MT practice need not specify the sequence in response to Inquiry 78-6 states with
method in the month total 44 or which requirements are completed. The regard to 8.6.3, The specific percentile
more and all other requirements for certification date may not be based on weight factors used should be clearly
certification are satisfied. completion of an individual requirement, stated in the employers written practice
*Withdrawn in June 1990. See such as an examination, but must be and should be based on the particular
Inquiry 89-3. concurrent with or subsequent to the date needs of the employer.
3. No. It is not intended that formal of completion of all requirements for Paragraph 9.3 of the SNT-TC-1A
classroom training in excess of certification. (1975 edition) provides that certification
minimum requirements be shall be based on Paragraphs 6, 7 and 8
substituted for experience. Hours but permits modification of those
spent in hands-on examination in Inquiry 85-7 requirements by the employers written
excess of minimum training practice. Therefore, the ultimate response
A question has arisen with regard to
requirements may be counted to the inquiry will be determined by the
the validity of Level III certification by
toward experience when that basis of the content of the employers
appointment in the case of the owner of
provision is contained in the written practice.
a company certifying himself.
employers written practice.
Response Inquiry 85-9
Inquiry 85-4 See Inquiry 81-9.1: An employer may 1. Can the personnel already approved
certify any employee as Level III by the 1980 edition conduct the test
1. Can an employer, acting as the provided the individual has the
certifying agency, certify a of both eddy current testing and
qualifications required by the employers magnetic leakage flux testing
Level III individual to SNT-TC-1A written practice.
criteria if that individual is a without any additional education
self-employed consultant? and/or qualification test?
2. If so, what method of certification Inquiry 85-8 2. If not, can the personnel already
should be used and what objective approved by the 1980 edition
Paragraph 8.6.3(C-2) of SNT-TC-1A conduct the testing of only the eddy
evidence should be available?
(1975 edition) requires a percentile current test? Is qualification based
weight factor 0.4 to 0.6 for on the 1980 edition effective only
Response
Specific-Practical NDT Level III concerning the eddy current test? If
1. Yes. A self-employed consultant examination grades. Is it acceptable to it is effective, is it necessary that
qualifies as an employee within the interpret this paragraph as follows? the personnel already approved by
intent of 2.1.5 and 2.1.7. either the 1980 edition or the 1984
2. The employers written practice Examination Weight Factor edition be identified respectively?
should describe a method of General 0.5 Wg
certification in accordance with the Specific 0.5 Ws Response
provisions of SNT-TC-1A. The Practical N/A Wp
objective evidence should be as 1. To be qualified and certified in the
described in the employers written magnetic flux leakage method,
Response
practice and should include personnel shall receive additional
In strict conformance with the education and a qualification
evidence of education, training,
recommendations contained in the examination in accordance with
experience and appropriate
SNT-TC-1A (1975 edition), the following SNT-TC-1A.
examinations.
apply to Level III examination and 2. Personnel certified in the eddy
certification: 8.5.3(c) Practical current method in accordance with
Inquiry 85-5 Examination Proficiency shall be SNT-TC-1A (1980 edition) are
demonstrated in selecting, specifying and qualified to perform only the eddy
See Inquiry 84-2. writing specifications and/or procedures current method. The certification
for the performance of the applicable record for an individual should
Inquiry 85-6 nondestructive tests using appropriate indicate the edition of SNT-TC-1A
reference material. applicable at the time of
Is it the intent of SNT-TC-1A that examination.
qualification requirements such as visual 8.6.3(c) NDT Level III
acuity, color vision and sufficient work Examination Grades:
experience be completed before the General 0.4 to 0.6
examination date and that the Specific-Practical 0.4 to 0.6
examination date be used as the final
certification date in lieu of the employer

Interpreting SNT-TC-1A 11
Inquiry 86-1 4.3.2. While it is good practice to
perform all NDT in accordance with a
3. If an individual is internally
certified as a Level III in Company
If an inspector has been given an eye written procedure, SNT-TC-1A only A, can that individual act as an
examination and found to have a prescribes written documents for the external Level III authority for
red/green color deficiency, can he be control and administration of NDT Company B and administer exams
qualified to perform magnetic particle personnel training, examination and for Level I and II personnel in
testing and liquid penetrant testing certification. See Paragraph 5.1. It does Company B?
providing the following color test is not prescribe that there exist a written
administered by a Level III? procedure applicable to each examination Response
1. Magnetic particle: a test shall be performed. The participation of ASNT
conducted using welds with known 1. No, as established by a precedent of
Level III is not a requirement under any Inquiry 86-2, though on a slightly
discontinuities to assure their aspect of SNT-TC-1A.
detection. A second test of different subject. The participation
production welds shall be given to of ASNT Level III (i.e., a holder of a
evaluate the inspectors ability to Inquiry 86-3 valid ASNT Level III certificate) is
distinguish between relevant and not a requirement under any aspect
Regarding the need for reexamination of SNT-TC-1A. The employers
nonrelevant indications. The of Level II technician on changing
inspectors certification shall be written practice should specify the
employers, it is our belief that provided requirements.
restricted to using only those colors that evidence exists of an examination to
used in the above tests, such as 2. No. See Inquiry 85-7.
SNT-TC-1A rules, the new employer may 3. Considering the response to
black powder, gray powder and/or recertify the technician to the previously
orange powder. Inquiry 81-9.2 and Inquiry 83-4.1
attained level providing he is satisfied and 83-4.2, the answer is yes,
2. Liquid penetrant: a test shall be that the technician meets the other
conducted using welds with known provided the Level III is acting as
conditions set by ASNT, regarding period Company Bs agent.
discontinuities to assure their of employment and date of recertification.
detection. A second test of
production welds shall be given to Response Inquiry 86-7
evaluate the inspectors ability to
distinguish between relevant and Inquiry 78-4.1 and Inquiry 80-9 It is requested that clarification be
irrelevant indications. established the precedent that the provided regarding whether an
examination referred to in Paragraph individual qualified in accordance with
Response 10.2 be administered by the new the 1984 edition is also qualified in
employer or obtain copies of the accordance with previous editions of
The color vision examinations examinations taken by the candidate at SNT-TC-1A, as referred by the ASME
described are in compliance with the the previous employer. This step is Boiler and Pressure Vessel Code.
intent of the SNT-TC-1A (1980 edition), necessary to ensure the quality of the
Paragraph 8.1.1.2 as well as the same examinations and to meet the Response
paragraph of the 1984 edition and documentation needs of
Paragraph 8.2(a2) of the 1975 edition Inquiry 85-2 established the
Paragraph 9.6.1.6. precedent that an individual once
and with prior Inquiry 78-11.2 and
Inquiry 81-15. The examinations should certified need not recertify to another
be documented in the written practice Inquiry 86-5 edition of SNT-TC-1A. However, as
required by Section 5 of those editions. addressed in Inquiry 84-1, Any or all
1. It is, of course, clear from editions [of SNT-TC-1A] could be
SNT-TC-1A that a company can use referenced in the employers written
Inquiry 86-2 an external Level III authority to practice, depending upon the
conduct Level I and Level II specification or code referencing
May a Level II as per ASNT examinations and to underwrite its
guidelines SNT-TC-1A legally inspect, for SNT-TC-1A to interpret what is required.
own certification procedures. I have If the individual is certified to the latest
example, the lifting devices of an always assumed that this Level III
industrial plant without a written edition of SNT-TC-1A, they are also
authority should be officially considered to meet the
procedure and a report of approval of an certified by ASNT and his name
ASNT Level III? recommendations of earlier editions.
would therefore appear on a current
list of such persons, issued annually
Response by you. Is this correct? Inquiry 87-1
The question of whether or not 2. It is also possible for a company to In accordance with the intent of
compliance with any provision of certify its own internal Level III SNT-TC-1A (1975, 1980 and 1984
SNT-TC-1A is legally necessary is authority with or without an editions), is it acceptable to allow credit
beyond the scope of SNT-TC-1A and examination provided it meets toward RT Level I qualification and
must be determined in the laws, codes other requirements of SNT-TC-1A certification for RT work time
and standards applicable to the facility of and of its own written practice. If experience which has been acquired
material being inspected. In situations an examination is administered, I while working as a trainee with and
where SNT-TC-1A is applicable, an NDT have assumed that it should at least under the direct supervision of certified
Level II may interpret and evaluate be carried out by an external Level I RT technicians who have met all
results with respect to the applicable authority certified at Level III by federal and/or agreement state
codes, standards and specifications and ASNT. Is this a true assumption? requirements for qualifications and
may report the results, as provided in designation as industrial radiographers?

12 Interpreting SNT-TC-1A
Response qualifier of experience pursuant to contracting agency. ASNTs position is
Yes, provided the Level I receives the Level III certification? that there is no equivalent to ASNT
necessary instructions or supervision 2. Should maintenance of a valid Level III certification.
from a certified Level II or III Level II certification over the
required qualifying time be
individual. See Paragraph 4.3.1.
considered to satisfy Paragraph Inquiry 87-5
Paragraph 4.2 of the 1975, 1980 and
1984 editions of SNT-TC-1A states, A 6.3.2 of SNT-TC-1A without A Level II is terminated from
trainee should work with a certified computation or criteria regarding Company A and is employed by
individual ... This certified individual the percent of time spent working in Company B as a trainee. Eight months
may be a Level I, II or III. Also, per the method? after termination, Company B certifies
Paragraph 4.3.2, The NDT Level II ... the employee to Level II.
should exercise assigned responsibility Response 1. May an employee working at a
for on-the-job training and guidance of 1. It is intended that 100 percent of the lower NDT level be upgraded to his
trainees and NDT Level I personnel. experience time specified in former NDT level without
The employers written practice should Paragraphs 6.3.2.1 or 6.3.2.2 or retraining?
detail the requirements for the trainees 6.3.2.3 be met in each applicable test 2. When certifying personnel in
work time experience. The certified method. The 25 percent rule of accordance with Paragraph 9.3, may
Level I RT technician who has met Note 3 in Table 6.3.1 is not training and experience documented
federal and/or agreement state intended to apply to 6.3.2. Note, by a former employer be considered
requirements as an industrial radiographer however, as stated in Paragraph in satisfying the criteria of
is outside the scope of SNT-TC-1A. 6.3.2, When the individual is Paragraph 6.3?
qualified by examination, the above
requirements may be partially Response
Inquiry 87-2 replaced by experience as a 1. Inquiry 84-3 established the
Does ASNT consider it acceptable certified NDT Level II, or in precedent that once an individual
for an NDT training school to hold a assignments at least comparable to has met the certifying employers
written practice and train, examine and NDT Level II, in other methods ... required training, even if the
certify individuals to that written as defined in the employers written training were attained while
practice? practice. The employers written working for another employer, it is
practice should specify the not necessary to repeat the training.
Response requirements. Based on this, the trainee could be
2. No. The intent of the experience certified to the former level.
No, unless the certified employee is a
requirement of Paragraph 6.3.2 is However, this assumes that all of
bona fide employee of the educational
that the candidate should be the certifying employers written
institution. SNT-TC-1A, Paragraph 1.3
actively working and acquiring practice requirements are satisfied.
states, These guidelines have been
progressive experience in the It should further be noted that based
developed ... to aid employers in
methods for which certification is on Paragraph 10.2.3 of SNT-TC-1A
recognizing the essential factors to be
sought. Just maintaining a valid (which requires recertification
considered in qualifying employees ...
certification does not meet this within six months of termination),
Paragraph 2.1.5 defines employer as:
intent. The employers written certification eight months after
The corporate, private or public entity
practice should specify the termination does not comply with
which employs personnel for wages,
requirements regarding qualifying the stated conditions. The
salary, fees or other considerations. An
work time experience. employers written practice should
educational institution can serve as an
employer and, as addressed in address this matter.
2. Yes. See Inquiry 80-12.4 and
Paragraph 5.1, establish a written Inquiry 87-4 Inquiry 84.3.
practice. The employers written practice
should address the basis for qualification A candidate has met the established
and published requirements for
and certification.
certification as Level III by a group other Inquiry 87-6
than ASNT. The scores were graded to Is it intended that an individual with a
Inquiry 87-3 the requirements of MIL-STD-410 and four-year degree in NDT or any four-year
SNT-TC-1A. Although not certified by scientific degree from an accredited
Paragraph 6.0 of SNT-TC-1A (1985
ASNT, could scores based on college and three years as a certified
edition) establishes recommendations
SNT-TC-1A requirements be acceptable Level II, who has not been performing
with respect to education, training and
by a contracting agency as equivalent to NDT examinations on a daily basis in the
experience pursuant to initial
ASNT certification, if all other particular method he or she is seeking
qualification. Table 6.3.1 lists
requirements are met? Level III qualifications, but has been
recommended training and experience
pertaining to Level I and Level II. The actively involved in the day-to-day
Response technical operations of a major NDT
25 percent rule is found in Note 3 to this
table, but not elsewhere in SNT-TC-1A. As stated in SNT-TC-1A, Paragraph organization, i.e., calibration block
1. What percent of a candidates time 9.1, Certification of all levels of NDT development, procedure writing (in the
is intended to be required (in the personnel is the responsibility of the method which he or she is seeking
same sense that the word required employer. Whether a contracting agency Level III) and involvement in other NDT
is used in the heading of accepts the scores as being equivalent to operations in the organization, be
Paragraph 6 of SNT-TC-1A) as a ASNT is solely up to the employers required to spend 25 percent of the

Interpreting SNT-TC-1A 13
preceding 12 months involved in the
particular method in which he or she is
Inquiry 88-2 graphs, etc.) provided by the
employers Level III examiner
seeking qualifications as Level III? When the recommendations of meet the recommendation of
SNT-TC-1A (1975 through 1984 editions) SNT-TC-1A for closed book written
Response have been made mandatory requirements examinations?
in the employers written practice, as is
See Inquiry 87-3. often required by other agencies, and Response
when personnel have been certified by a
1. No. This is a minimum. Other
Inquiry 88-1 new employer under SNT-TC-1A
specifications may be covered at
Paragraph 10.2, what records must the
1. In accordance with the intent of new employer obtain to satisfy himself the employers option.
SNT-TC-1A (1975, 1980 and 1984 that the requirements of 10.2 have been 2. No. Specifications used by the
editions), may an employer prepare met? employer should be covered as a
a written practice which permits minimum. Other specifications may
Level III leak test qualification and Response be included at the employers
certification in three, two or even option.
one of the four leak testing Response to Inquiry 77-10 states: 3. No. Questions which can be
techniques identified in Table 6.3.1 The specific documentation to be answered directly from necessary
of SNT-TC-1A? furnished by new employees and past data, such as graphs, tables,
2. When a limited Level III leak test employers and the means for obtaining specifications, procedures, codes,
certification in three, two or even documentation is referenced in etc., may demonstrate an ability to
one of the four leak testing Paragraphs 9.6 and 10.2 of SNT-TC-1A. utilize the material but do not
techniques is intended, may the Details should be included in the demonstrate an appropriate
questions used in the Level III employers written practice. Paragraph knowledge of the equipment,
Method and Specific examination 1.2 of SNT-TC-1A identifies the fact that operating procedures and NDT
be selected primarily or even the document (SNT-TC-1A) provides techniques that the individual may
exclusively for the leak testing guidelines for the establishment of a encounter.
techniques for which the limited qualification and certification program. If
certification will apply? an employers written practice is made
mandatory by another agency, it is Inquiry 89-2
Response ASNTs position that the extent of If Specific examination questions are
compliance to Paragraphs 9.6 and 10.2 taken directly from the data provided,
1. Yes. Inquiry 82-1 established the must be addressed in the employers
precedent: (a) Paragraph 4.1 (1975 such as applicable procedures or codes,
written practice to the degree necessary does this meet the implied definition of a
edition) permits subdivision of the to satisfy that agency.
basic levels of qualification as closed book examination, assuming all
needed to fit the employers needs; questions were selected and approved by
the scope of these subdivisions may Inquiry 89-1 the responsible Level III?
be greater or less than the 1. Is it the intent of SNT-TC-1A that
guidelines of SNT-TC-1A; and (b) Response
Specific examination questions
education, training and experience about specifications, codes and No. See Inquiry 89-1.3 and
guidelines of Paragraph 6 and Table acceptance criteria be limited to Inquiry 77-5.
6.2.1(a) should be modified to meet those used during specific
the needs of the subdivisions in assignments? General Comments
accordance with Paragraph 4.1. 2. Do Specific examination questions The term closed book in
Note: Table 6.2.1(a) in the that are designed to demonstrate an Paragraphs 8.5, 8.3, 8.3 and 8.7 of the
1975 edition was renumbered as applicants ability to comprehend 1975, 1980, 1984 and the 1988 editions
Table 6.3.1 in the 1980 edition. and utilize specifications, codes and (respectively) of SNT-TC-1A should be
Paragraph 4.1 was revised also in acceptance criteria similar to those interpreted with the degree of flexibility
the 1980 edition. However, the used by an employer in his needed to make it fit the employers
intent has remained consistent in all nondestructive testing procedure situation, as required by Paragraph 1.4 of
three editions. but are not directly applicable to the SNT-TC-1A.
2. Yes. Paragraph 4.1 permits the procedures used for specific The intent of SNT-TC-1A
subdivision of the basic levels of assignments meet the intent of examinations is to determine that the
qualifications as needed to fit the SNT-TC-1A? candidate is capable of correctly applying
employers needs; thus, it would be 3. Do Specific examination questions the necessary information to real testing
considered appropriate to select that are designed to demonstrate an situations.
Method examination questions applicants ability to comprehend Furthermore, it is generally considered
specifically for the particular leak and utilize specifications, codes and good practice for personnel to refer to the
testing techniques for which a acceptance criteria similar to those applicable graphs, tables, codes and
limited certification is being sought. used by an employer in his or her standards while conducting tests in order
For Basic examinations, other nondestructive testing procedure to reduce the potential for error. For an
techniques of leak testing, as well but are formulated in such a manner employer who uses such good practices,
as other nondestructive test that every question in the Specific it would be unreasonable and
methods should be covered in examination may be answered inconsistent with the intent of
accordance with directly by reviewing the reference SNT-TC-1A to give examinations without
Paragraph 8.3.3.1(e). material (NDT procedure, charts, allowing the use of pertinent reference

14 Interpreting SNT-TC-1A
material when this reference material is practice added no further requirements in related to the ability to interpret
provided by the designated examiner. addition to those in SNT-TC-1A. codes, standards and specifications
However, when use of reference generally related to method (not
material with an examination is specific to the employer) may be
permitted, the examination questions Inquiry 89-4 included as part of the Level III
should require the exercise of judgment, In the 1968, 1975, 1980 and 1984 Method examination.
analysis or computation to the degree editions of SNT-TC-1A, an employer may 2. No. As noted above, this is a matter
needed to demonstrate the candidates waive examinations for the Level III and for the employers written practice
ability to deal satisfactorily with real thereby certify the individual by and depends upon the details of
testing situations. It would not meet the appointment. what is expected of the Level II by
intent of SNT-TC-1A if the examination There is no such provision in the 1988 that employer.
could be passed by simply finding, in the edition. However, it is implied by the
reference material, the correct piece of statement in Paragraph 6.3.2: When the
data or the particular sentence needed to individual (Level III) is qualified by
Inquiry 89-6
answer the questions. examination ... Is it the intent of SNT-TC-1A to permit
May the employer waive examination administration of the certification
for the Level III and be in compliance examination prior to commencing the
Inquiry 89-3* with the intent of SNT-TC-1A (1988 experience time for a certain level? For
Based on a review of published edition)? example, an individual completes the
inquiries in the 1988 Redi-Reference recommended training and the general,
Guide (Materials Evaluation, Vol. 46, Response specific and practical examinations for
No. 2), there appears to be a conflict and It is intended by the 1988 edition of Level I. The experience time then
an open item related to Inquiry 83-10 and SNT-TC-1A that all Level IIIs initially commences and at the completion of the
Inquiry 85-3.2. certified after issuance of the 1988 minimum experience period, certification
Inquiry 83-10 restated: Please edition of SNT-TC-1A be qualified by becomes effective as of that date.
interpret the 25 percent rule for a trainee examination.
in one method who is also performing Also see Inquiry 90-2 and Response
NDT in a method for which he is already Inquiry 92-2. SNT-TC-1A states in Paragraph 5.1:
qualified and certified. The employer shall establish a written
*Withdrawn by interpretation panel practice for the control and
action (June 1990). Inquiry 89-5 administration of NDT personnel
Inquiry 85-3.2 restated: May an training, examination and certification.
1. Because Level III personnel
individual be certified to Level I in the The time of examination should be
primarily interpret codes and
MT method after working one to three specified in the employers written
specifications and Level II
hours per day every day for one month practice.
personnel generally follow
while also performing regular duties as a However, it is difficult to understand
approved procedures, shouldnt
Level II in the PT method? how an individual requiring experience
Level III Specific examinations
*Withdrawn by interpretation panel in order to become qualified can
consist mostly of questions that test
action (June 1990). satisfactorily pass an appropriately
the candidates ability to interpret
codes and specifications rather than difficult practical examination prior to
Response obtaining the necessary experience. If an
procedures which the candidate, in
(Reconsideration of Inquiry 83-10)
fact, may have written? employer believes that this is satisfactory
The intent is that a full-time inspector 2. Should the Level II Specific under some circumstances, these
working in more than one method may examination deal more with the circumstances should be clearly specified
simultaneously receive full-time requirements and acceptance in the employers written practice.
experience credit for all methods in criteria contained in the procedures
which he is pursuing certification if at which will be used by the candidate
least 25 percent of his work time is spent rather than questions from codes
Inquiry 89-7
in each method for which he is claiming and specifications from which the In reference to the SNT-TC-1A (1984
credit. The remainder of his work time procedures are developed? edition), we want to know if the words
must be spent in other NDT or should and shall have a specific
NDT-related activities, as a trainee or as Response definition. If these words have a specific
a certified inspector and as defined in his definition, what is the scope of each?
1. No. This is a matter which should
employers written practice. Example: A
be detailed in the employers
PT Level II, with no UT experience, Response
written practice. The examination
begins to accumulate experience toward
should include questions that test No. The words should and shall do
UT qualification with the goal of
the candidates knowledge of not have a specific definition applicable
becoming a UT Level II. He works
procedures, as well as questions to the 1984 edition of SNT-TC-1A.
25 percent of his time in UT and the
related to equipment and techniques The implied intent of these words
remainder in PT. Under these conditions,
applicable to the employers initially was that shall was used to
he would have the necessary experience
product and methods, to the express the importance of a particular
to qualify as a UT Level I after three
administration of the employers function or activity to be considered by
months elapsed time and as a UT
written practice and to codes, an employer in the written practice,
Level II after nine additional months
specifications and standards whereas should was intended to denote
elapsed time if his employers written
directly applicable to the a suggested or recommended function or
employers activities. Questions activity which could or should be

Interpreting SNT-TC-1A 15
considered for inclusion in an employers Response enough ability to be able to certify
written practice. The answer to your question from an another individual?
A conflict in the intended usage of NCB standpoint is no. The reason why is
these two verbs was introduced by a stated above: the ASNT Level III Response
regulatory body which interprets the Program is a separate activity 1. The inference of the statement,
words shall and should when used in administered by Board-appointed Signature of Designated
their code as shall meaning mandatory members through headquarters and is not Representative, in Paragraph
and should being preferred. governed by SNT-TC-1A. Due to the 9.6.1.10 of SNT-TC-1A (1980
To further clarify ASNTs position on nature of the examinations and because edition), is that whoever is
the use of these words in the context of of confidentiality requirements, no one identified by the employer in their
SNT-TC-1A, the 1988 edition of but NCB members have access to these written practice as the designated
SNT-TC-1A now defines shall and examinations. representative, may sign the record
should in Section 2.1 as of certification.
(8) Shall: a verb used to express the 2. No. Paragraph 4.3.3 of SNT-TC-1A
minimum recommended guidelines for Inquiry 89-11 (1980 edition), states ASNTs
most employers qualification and recommendations for an employer
1. Can one waive the training
certification programs; this is intended to to consider when selecting their
requirement on the basis of
express what is mandatory by law or Level III. The last sentence specifies
previous documentable work
regulation. that a Level III should be familiar
experience and test by examination
(9) Should: a verb used to express the with other methods and should be
for certification?
desired guidelines for most employers qualified by experience and
2. Can one waive the training
qualification and certification programs. training. The intent is to train and
requirements on the basis of
previous documentable examine Level I and Level II
Inquiry 89-8 certification, for certification? personnel for certification in the
methods in which he or she is
See SNT-TC-1A (1988 edition), Response qualified. This is further clarified in
Section 4.3. Can an NDT Level II SNT-TC-1A (1988 edition),
establish a specific technique he or she 1. No. Training cannot be waived.
Paragraph 4.3.3, which states, The
will use in an NDT method with an Training and experience are
NDT Level III, in methods in
approved general procedure without different elements of qualification.
which certified, should be capable
approval of an NDT Level III? Training is a required segment of
of training and examining NDT
qualification with recommended
Level I and II personnel for
Response times related to education levels.
certification in those methods.
Work experience and examinations
This issue should be addressed by the are the other elements considered in
employers written practice. The
employee must be qualified to perform
qualification for certification. Inquiry 90-2
2. No. The employer must evaluate the
the work to be accomplished. elements of previous certification to 1. Is it the intent of ASNT that all
determine whether the elements of Level III personnel certified to the
1988 edition be examined?
Inquiry 89-10 the current employers program
2. In accordance with SNT-TC-1A
have been satisfied by a previous
It has been determined that the subject employers program. (1988 edition), an employer
question as submitted does not constitute certifies his corporate Level III by
a request for clarification of a stated examination through an outside
SNT-TC-1A recommendation. The Inquiry 90-1 service. However, the outside
question addresses the ASNT Level III services Level III was certified by
1. Paragraph 9.6.1.10 states:
program administered by ASNT under the appointment to SNT-TC-1A (1984
Signature of Designated
direction of the Level III Program edition). Is the employers Level III
Representative. Should the
Committee or, after 1990, through the certification valid to the 1988
employers representative signing
National Certification Board (NCB). The SNT-TC-1A?
for certification be a certified
Level III program is an administrative Level III examiner in the specific
function and is a separate entity from Response
discipline or can it be signed by an
SNT-TC-1A. Therefore, this inquiry is not individual with no certification in 1. Yes. As stated in the response to
considered a valid request for that discipline but is a certified Inquiry 89-4, ... It is intended by
interpretation. Level III examiner in a different the 1988 edition of SNT-TC-1A that
However, in response to your concern, NDT process? all Level IIIs initially certified after
the interpretation panel answers the 2. Paragraph 4.3.3 states in part that issuance of the 1988 edition of
following question: Do electric utilities ... the NDT Level III should have SNT-TC-1A be qualified by
that employ personnel who have been general familiarity with other examination. See Inquiry 89-4 and
certified to perform nondestructive appropriate NDT methods and Inquiry 92-2.
examination in accordance with should be qualified to train and 2. Yes, provided the employer has
SNT-TC-1A routinely audit the examine NDT Level I and Level II assured that the examination
certification process of ASNT? If not, personnel for certification. Does services are in accordance with the
why? the general familiarity with other employers written practice per
appropriate NDT methods mean a Paragraph 9.5 of SNT-TC-1A (1988
Level III [is] required to have edition).

16 Interpreting SNT-TC-1A
Inquiry 90-3 Response Inquiry 91-4
Paragraph 4.3.3 in SNT-TC-1A (1988 As previously stated in the response to According to SNT-TC-1A (1984
edition) states that the NDT Level III Inquiry 87-3, it is intended that edition), when an employee has been
shall have a general familiarity with 100 percent of the work experience time tested to Level III requirements by an
other appropriate NDT methods, as specified in Paragraph 6.3.2 be met in outside agency and certified as a
demonstrated by the ASNT Level III each applicable test method prior to Level III by his or her employer on the
Basic examination or by other means. certification. basis of these tests:
1. Is it the intent of SNT-TC-1A that When the individual is qualified by 1. Can the employee be recertified
other means be written examination, the above requirements based on the employers statement
examination administered by a may be partially replaced by experience of continuing satisfactory
Level III? as a certified NDT Level II or by performance?
2. Is it the intent of SNT-TC-1A that assignments at least comparable to NDT 2. What constitutes evidence of
other means be examinations, Level II in other methods listed in continuing satisfactory
written or practical, administered Section 3 of this Recommended Practice performance?
by a Level III? as defined in the employers written 3. Must the certification be given by
practice. another NDT Level III employed
Response by the company or may it be given
No. The intent of the statement other Inquiry 91-2 by a company official?
means is to provide the user of Does Recommended Practice No.
SNT-TC-1A with sufficient latitude under Response
SNT-TC-1A (1984 edition) exclude an
Paragraph 1.4 to identify specifically employer from developing its written 1. Paragraph 9.7.1 of SNT-TC-1A
how they would evaluate the extent of a practice utilizing visual examination as allows for recertification with
Level IIIs general knowledge of other an NDT method? evidence of continuing satisfactory
NDT methods, as defined in his written performance. An employee may be
practice. Response recertified with evidence of
continuing satisfactory performance
No. As previously stated in the if addressed in the employers
Inquiry 90-4* response to Inquiry 78-7 and 80-8, the written practice.
Is it acceptable for a candidate for intent of Paragraph 1.4 is to provide the 2. The intent of evidence of
Level III certification under SNT-TC-1A employer adequate flexibility to continuing satisfactory
(1988 edition) to be qualified on the accommodate a variety of special needs performance in Paragraph 9.7.1 of
basis of demonstrated ability, as documented in a written practice. SNT-TC-1A is that the employer
achievement, experience and education shall have objective evidence of an
in lieu of qualification by examination as Inquiry 91-3 individuals satisfactory perfor-
stated in Paragraph 9.6(g)? mance during the previous certifi-
May a Level III or his designated cation period of the appropriate
Response representative administer eye duties outlined in the employers
examinations? According to written practice.
No. Paragraph 8.8 specifically requires Paragraph 8.1, a Level III or his 3. As previously stated in the response
that a Level III candidate be qualified by designated representative shall to Inquiry 90-1, the inference of the
examination. Paragraph 9.6(g) addresses administer and grade the examinations statement signature of designated
the content of the qualification records specified in Section 8.3 to 8.8. Paragraph representative in Paragraph
file to be maintained by the employer of 8.2 (which covers eye exams) is not 9.6.1.10 is that whoever is
certified personnel. addressed in this statement nor are any identified by the employer in their
*This Response was reconsidered. See qualified individuals addressed in 8.2. written practice as the designated
Inquiry 92-2. Also see Inquiry 89-4 and Should Paragraph 8.1 read 8.2 through representative may sign the record
Inquiry 90-2. 8.8 or are Level IIIs not permitted to of certification.
administer eye exams and if so, who is?
Inquiry 91-1 Response Inquiry 91-5
Assuming 2,100 hours are worked
As previously stated in the response to Is it the intent of Table 6.3.1 (1984
each year, is it the intent of Paragraph
Inquiry 78-11, it is intended that edition) that, for initial certification to
6.3.2 that a candidate should work
Level III personnel be allowed to Level III PT, the recommended three
2,100 hours to claim one year of
administer the near-distance vision acuity months of experience must be
experience or that a candidate should
examination. However, if the employer accumulated in consecutive months?
have been active in the methods during
elects to use other methods of vision Assuming the individual is being certified
the year?
examination, it may be necessary to use directly to Level II, does not perform
Example: A candidate works 2 hours
personnel with other specialized NDT full time and the 25 percent rule
per month (24 hours) as a Level II in PT
qualifications to administer the cannot be applied.
and 173 hours per month (2,076 hours)
in other methods. At the end of the year, examination. The employer should
include details of the qualifications Response
the candidate claims one-year experience
in PT. required of examiners in the written No. As stated in Paragraph 6.3.1, the
practice. intent of Table 6.3.1 is to list the
recommended training and experience
factors to be considered by the employer

Interpreting SNT-TC-1A 17
in establishing written practices for initial Certification of NDT personnel shall be 3. In the case of Level III certification
qualification of Level I and Level II based on demonstration of satisfactory by appointment, dated June 6,
individuals. There is no provision to limit qualification in accordance with 1990, would this example be valid?
the time period over which the Sections 6, 7 and 8, as modified by the
experience may be credited. employers written practice. Response
Therefore, a candidate for Level III 1. Yes.
could be qualified on the basis of
Inquiry 92-1 demonstrated ability, achievement,
2. SNT-TC-1A is a recommended
guideline. As such, it is to be used
Please clarify the response to Inquiry experience, and education in lieu of by employers in developing their
78-4, question 2, as it applies to examination, if specifically addressed in own requirements. Therefore, the
SNT-TC-1A (1975 edition). the employers written practice. employer may accept the appointed
1. Is it necessary for the recertification Also see Inquiry 89-4 and Level III certification of the 1984
of a previously qualified and Inquiry 90-2. edition as satisfying the 1988
certified individual to obtain further edition, if specified within the
experience in the applicable method,
in addition to refresher training?
Inquiry 93-1 employers written practice. See the
response to Inquiry 85-2 and
2. If a written practice contains a Is it the intent of Paragraph 9.7.3 that Inquiry 86-7.
provision to administer only any time a certified employee attempts a 3. Yes, see the response to
additional training prior to the certification examination in the method Inquiry 92-2.
examination process, would the certified and fails, his current
intent of Paragraph 10.2 be certification shall be revoked?
satisfied? Example: A Level I employee was Inquiry 93-3
issued a certification with a three-year NDT technicians are employees of the
Response expiration date. Two years after state. The states register has identified
1. As previously stated in the response certification he attempts a Level II the Qualification and Certification
to Inquiry 78-4, when an individual examination and fails. Is the Level I Committee as being responsible for the
has proof of prior certification but certification still valid or should the qualification and certification of NDT
has not worked in the method employee be reexamined in accordance personnel. In addition, the committee is
within the immediate six months with Paragraph 8.10 prior to allowed to approve and use testing
prior to termination or the reinstatement of his certification? centers for examinations.
individual is being recertified after If the NDT technicians work for a
more than six months have passed Response subsidiary of a corporation, who does
since termination, additional The intent of Paragraph 9.7.3 is to ASNT recognize as the employer for the
training and experience is allow an employer to reexamine an sake of certification?
recommended. Whether or not individual at any time (employers
additional training or experience is discretion) for the purpose of extending Response
necessary must be determined and an existing certification (i.e., recertify an It is against ASNT policy to judge on
detailed in the employers written individual to the same method and level) the applicability of employer policies and
practice. or for revoking an existing certification. documents.
2. Paragraph 10.2 addresses specific The specific details of extending or The SNT-TC-1A Interpretation Panel
conditions for the recertification of revoking an existing certification must be was established to respond to written
terminated Level I or Level IIs documented in the employers written inquiries about Recommended Practice
solely by examination. Inquiry 78-4 practice. No. SNT-TC-1A, Personnel Qualification
addresses the general In the example, since a higher level and Certification in Nondestructive
recommendations for recertifying certification was attempted and failed, Testing. The responses clarify the intent
individuals who do not meet the the existing lower level certification of ASNTs Technical and Education
requirements of 10.2. The would be considered valid for the Council and recommendations of
employers written practice must remainder of the certification period. SNT-TC-1A.
detail such provisions in
accordance with Paragraph 1.4.
Inquiry 93-2 Inquiry 93-4
Section 8.8, part 4 and part 5 refer to a
Inquiry 92-2 valid ASNT Level III certificate.
If an individual is certified as a
Level I in MT and is progressing to
Based on a review of inquiries 1. Is the ASNT Level III certificate Level II certification per the 1980 edition
published in Materials Evaluation, the endorsement limited to persons of SNT-TC-1A, does the individual need
following text is provided to clarify an tested by ASNT? an additional three months of experience
earlier response. 2. A person was appointed as a or are only two months of experience
Level III in June 1988, in needed since the individual already
Response accordance with the recommended acquired one month of experience for
(Reconsideration of Inquiry 90-4) guidelines of the 1984 edition Level I?
SNT-TC-1A (1988 edition) SNT-TC-1A for a five-year period.
recommends that a candidate for Is that person meeting the
Level III be qualified by examination. requirements of the 1988 edition
However, Section 9.3 states through May of 1993?

18 Interpreting SNT-TC-1A
Response personnel training, examination, and 3. No. Level I certification is valid
Yes, the individual will require an certification. The employers written until the expiration date. At that
additional three months of experience. practice should identify who is time, the individual should be
responsible for the administration and recertified according to the
grading of examinations. It should also employers guidelines. See
Inquiry 94-1 identify the method used to identify a Inquiry 85-2, Inquiry 86-7 and
Level IIIs designated representative. Inquiry 93-2.2. Based on Sections 5
Please clarify ASNTs intent regarding
When not specifically addressed in the and 9 of SNT-TC-1A, certification
the phrase, assignment comparable to
written practice, designation of a of all levels of NDT personnel is
that of an NDT Level II as it related to
representative becomes wholly the the responsibility of the employer.
SNT-TC-1A, 1984 edition, Paragraph
responsibility of the NDT Level III. A
6.3.2.1. I interpret this statement to
Level IIIs signature on the examination
mean: even though an individual has a
or certification may be accepted as Inquiry 96-2
four-year degree in science or
designation. Is it the intent of SNT-TC-1A that any
engineering, he/she should also have the
documented NDT training and individual examination grade less than
70 percent should be considered a failing
experience commensurate with that of a Inquiry 96-1 grade?
Level II. This documented training
should follow the guidelines established 1. [Ref: 8.8.1(b) and 8.8.1(c), 9.5.1]
in Table 6.3.1 of SNT-TC-1A (1984 The number of examination Response
edition). It also requires (in my opinion) questions is increased by Section Yes.
this individual practice as a Level II for 8.8.1(b) and 8.8.1(c). Shall the
at least one year before being eligible for NDT Level III who has been
Level III certification. qualified with the examination in Inquiry 96-3
accordance with an earlier edition
When applying SNT-TC-1A 1992
Response and continuing satisfactory
edition in strict accordance with the
performance be required to take an
Please reference Inquiry 83-8. document, is it ASNTs interpretation
additional examination until his
that a Level III must be examined?
next requalification?
Inquiry 94-2 2. [Ref: 8.8.2(a)] The revised
Response
requirements deleted the selection
I have a question regarding the of questions from published ASNT No. Certification of all levels of NDT
certification hours. In Table 6.3.1 of the Level III questions and required personnel is the responsibility of the
SNT-TC-1A recommended practice for a questions similar to. Do the employer. It is the intent of ASNT to
UT certification, it shows that the requirements intend to prohibit to certify Level IIIs by examination.
requirement for Level I is three months make or adopt the same questions However, the employer can specify the
and Level II is an additional nine as ASNT Level IIIs? requirements for a certification route
months. Three months at 40 hours per 3. [Ref: 8.5(4)] Shall the NDT without examination in the employers
week translates into 480 hours; nine Level I, who was qualified in written practice. Please see Inquiry 80-9,
months at 40 hours per week translates accordance with an early edition Inquiry 89-4, Inquiry 90-2, Inquiry 90-4
into an additional 1,440 hours. I am and continuing satisfactory and Inquiry 92-2.
currently doing thickness testing. My performance, be required to take an
question is: How much of that time additional examination evaluating
should be shear wave inspection in order the practical examination results,
Inquiry 99-1
to be an unrestricted Level II according until next requalification, if their May an employer use the training and
to ASNT recommendations? written practice stipulates the experience hour requirements specified
specific evaluation of acceptance in the 1984 edition of SNT-TC-1A for
Response for the NDT Level I? personnel who have not graduated from
Please reference Inquiry 80-3. high school and are being qualified to the
Response 1992 edition of SNT-TC-1A?
1. No. Level III certification is valid
Inquiry 95-1 until it is expired. At that time, the Response
If the person who administered and individual should be recertified Yes.
graded an examination is identified on according to the employers
the examination and on the certification, guidelines. See Inquiries 85-2, 86-7
and the examination and certification are and 93-2.2. Inquiry 99-2
signed by the Level III certifier, does the 2. No. ASNT Level III questions are Is it the intent of the 1992 edition of
Level III need to issue a letter or administered by ASNTs SNT-TC-1A, that a person without a high
statement delegating that person as their Certification Management Board school diploma or equivalent, not be
representative? (formerly the National Certification certified to any NDT level?
Board). The questions are similar to
Response those of a Level III Study Guide. Response
Section 5.1 states: The employer Both sets of questions can be but
No.
shall establish a written practice for the may not necessarily be the same.
control and administration of NDT See Inquiry 79-2.

Interpreting SNT-TC-1A 19
Inquiry 99-3 develop a written practice for vibration
analysis. The two groups are not
Response

Is it the intent of SNT-TC-1A that any No. Should be addressed in


connected in any way. They have employers written practice.
composite examination grade less than different managers and locations. Is it
80 percent should be considered a failing permissible to have two separate written
grade? practices, one for TIR and one for VA Inquiry 01-4
personnel?
Response We are an inspection company in Iran
and would like to edit our written
Yes. Response
practice for training and qualification of
Yes. NDT personnel. However, I have the
Inquiry 99-4 1988 edition of ASNTs Recommended
Inquiry 00-3 Practice No. SNT-TC-1A, where
Paragraph 4.0 (Levels of Paragraph 8.3.4 states that, on the basis
Qualification) of SNT-TC-1A 1984 How can an employer who wishes to of demonstrated ability, achievement,
edition permits those levels to be further utilize the services of an outside agency experience, and education, as defined in
subdivided by the employer for specific adopt that agents written practice, course Par. 4.3(3) and 6.3, the employer may
situations. Is there sufficient latitude instruction or examination particulars as waive examination for the Level III
within that paragraph to permit an acceptable as is within his written individual. I would like to know
employer to certify a person who is not practice? whether this point still holds good and
qualified or certified in any method, as can we still rely on it to appoint a
an Administrative Level III? Response company Level III?
Reference Inquiry 77-3.
Response Response
No. See Inquiries 88-1 and 82-1.
Under the recommendations of
Inquiry 01-1 Yes, if you are operating under the
1984 or an earlier edition. You should
SNT-TC-1A it is not permissible for an I am inquiring of ASNT regarding an note that Paragraph 8.3.4 was dropped
employer to certify an individual who is NDT Level IIIs scope of authority. I from SNT-TC-1A in the 1988 and all
not qualified (or certified) in any method have asked several ASNT NDT subsequent editions.
as an NDT Level III, Administrative or Level IIIs locally regarding this matter
any other title. and have received several answers. Can
Paragraph 3.1 of SNT-TC-1A identifies an NDT Level III (not ASNT NDT Inquiry 01-5
the nondestructive testing methods where Level III) perform third party Level III Is the color vision test mandatory for
qualifications and certifications are services for outside companies (this ASNT Level II qualification in
awarded. Paragraph 4.3 identifies NDT particular Level III is operating under the radiographic testing?
Level I, NDT Level II and ASNT NDT 1996 edition of SNT-TC-1A)?
Level III as the basic levels of Response
qualifications. Paragraph 4.1 allows these Response
levels to be further subdivided by the Yes. That is, the color contrast
Yes. differentiation examination is mandatory.
employer for specific situations. It is
intended that the subdivided levels be The color contrast differentiation exam
method specific and detailed in the Inquiry 01-2 should demonstrate the capability of
employers written practice. The distinguishing and differentiating contrast
Was or is it the intent of ASNT to among colors or shades of gray used in a
provisions of Paragraph 9.3 apply to the prohibit the appointment of qualified
certification of all NDT personnel method as determined by the employer.
personnel to Level III positions, making
including subdivided levels. examination mandatory, as our
authorized inspection company has Inquiry 01-6
Inquiry 00-1 interpreted it? Who can administer the vision tests,
Whose responsibility is it to near vision acuity and color contrast
personally maintain the certified Response differentiation? I understand that the near
employees records and handle the files? No. Refer to Inquiry 92-2. vision test should be administered
The employer? The appointed ASNT annually and the color contrast
NDT Level III? The human resources differentiation test upon initial
department? Or anyone assigned by the Inquiry 01-3 certification and at three year intervals.
employer? Does a Level I NDT technician But who can do it? A Level III who is in
require a high school diploma? ASNTs charge of the certification program?
Response Recommended Practice No. SNT-TC-1A Medical personnel? What about the color
Responsibility for maintaining records does not specifically list initial training contrast differentiation test?
should be addressed in the employers or experience recommendations for
written practice. personnel without a high school Response
education and I need to know how to Any personnel designated in the
Inquiry 00-2 certify a man who has done NDT work employers written practice to administer
for years but does not have his diploma. the vision tests.
A company has a written practice for
TIR personnel. They then become a part
of the quality control group and want to

20 Interpreting SNT-TC-1A
Inquiry 01-7 highly qualified in the relevant
NDT field or can he or she be a top
Inquiry 01-10
I work for the Department of Defense management representative (in our We sometimes recertify persons
and Im in the middle of reviewing a case, our divisional head that is, periodically based on Paragraph 9.5.1.a
contractors written practice, which vice president of maintenance) who on recertification in the 1996 edition of
supposedly was written in accordance is knowledgeable in NDT but who SNT-TC-1A, which cites evidence of
with SNT-TC-1A. According to the does not have qualification in the continuing satisfactory performance. At
contractors written practice, SNT-TC-1A NDT field? present, my qualification to date has been
allows the employer to waive Level III 3. It is well understood that ASNT NDT Level III RT. Will I be able
examinations. In accordance with SNT-TC-1A is a guideline and that to issue a certificate (with my signature
Recommended Practice No. SNT-TC-1A, the employer can modify it on the certificate) for someone who is
based on demonstrated ability, reasonably to meet any specific being recertified by the above route?
achievement, experience, and education, needs warranted under the
the employer may waive examination for circumstances and/or applications. Response
the Level III individual. It doesnt say There are various organizations and Yes.
anything about having a valid ASNT schemes in NDT qualification/
NDT Level III certificate. Is this true? certification such as ISNT (Indian
Note that the contractor is required to Society for Nondestructive Inquiry 01-11
utilize the latest version of SNT-TC-1A. Testing), DIN, MIL and Japanese 1. May a Level III perform a color
certification schemes. Each has its contrast differentiation test along
Response own constitution and procedure for with the near vision acuity test as
Yes. Reference Inquiry 85-7 and NDT personnel qualification mentioned in Paragraph 8.2 of
81-9.1. countrywide. If somebody in my SNT-TC-1A (1996), if documented
company is preexisting with other so in the written practice?
than ASNT Level I or II 2. Is it also required to perform a test
Inquiry 01-8 certification status (like ISNT) or of gray shades, if the color contrast
1. Paragraph 8.1.1 of SNT-TC-1A if a new person joins my company differentiation test is performed as
(1992) reads: An NDT Level III with some other Level I or II per Paragraph 8.2 of SNT-TC-1A
shall be responsible for the certification status, considering his (1996) using the Ishihara series of
administration and grading of competency, education and course plates and so documented in a
examinations specified in Section coverage in that method, can I written practice?
8.3 through 8.8 for NDT Level I, II, certify him or her to equal/
or other Level III personnel. The equivalent ASNT NDT level status Response
administration and grading of by modifying the companys
written practice accordingly? That 1. Yes.
examinations may be delegated to a 2. Yes.
qualified representative of the NDT is, can an ASNT NDT Level III
Level III and so recorded. The certify ISNT (or some other)
actual administration and grading Level I or II person to an equal
ASNT NDT level based on
Inquiry 01-12
of Level III examinations specified
competency, education and course In the 1996 edition of SNT-TC-1A,
in 8.8 may be performed by a
coverage in the method? Paragraph 9.4 states (in part) that
qualified representative of the
4. Is the existence of a company NDT personnel certification records shall be
employer.
personnel certification procedure maintained on file by the employer.
In reference to the above paragraph, a written practice equally Who is it that actually maintains the
what is meant by a qualified important and required for NDT records? The companys human
representative of the NDT personnel irrespective of industry resources department? The companys
Level III to whom an NDT type? personnel department? The companys
Level III can delegate authority for appointed Level III person? The
administration and grading for Response certifying authority? Is it a common
NDT Level I, II or other Level III practice to delegate this task to the
personnel? Please explain 1. Needs to be addressed in appointed NDT Level III person as per
specifically the term qualified. employers written practice. the written practice?
What shall be the extent of the 2. See Inquiry 95-1.
qualification of the person? Does it 3. Yes. Response
mean that the person should be 4. Yes.
highly qualified in the NDT field or Needs to be addressed in employers
written practice.
can the person here be a responsible
management representative?
Inquiry 01-9
2. Again in reference to the above Regarding Paragraph 8.2.2 of
SNT-TC-1A, is there a recognized method
Inquiry 01-13
paragraph, what is meant by
qualified representative of the for differentiating shades of gray used in This is in relation to Paragraph 10.2
employer? What is the level of the method (radiography)? of the 1996 edition of SNT-TC-1A. One
qualification necessary in this case? division of company A was merged and
For NDT Level III certification by Response acquired by company B. All of the
the employer, is it required for the employees of its division were hired by
SNT-TC-1A does not define a specific company B within six months and their
person who will issue certification method. The specific method is up to
to the ASNT NDT Level III to be job activities did not change. The
employer discretion.

Interpreting SNT-TC-1A 21
employer of company B designated the 87-2 implies that only bona fide 2. No.
Level III personnel of company A as the employees can be certified. 3. SNT-TC-1A (1984) provides the
outside agency. The employer established 1. Is it the intent that employers user sufficient latitude under
a written practice, which was prepared certify only their qualified Paragraph 9.7.1 to identify
by the Level III of company A. In the employees? specifically how they would
written practice, it is specified that the 2. Is it the intent that employers, when evaluate evidence of continuing
employer can waive the examination in permitted by their written practice, satisfactory performance. The
cases where the job activities are the certify qualified nonemployees? requirements should be documented
same as they were in company A. May 3. Would the answer in question 2 in the employers written practice.
the employer of company B certify the change if a third party, who agreed 4. There are no specific provisions in
employee who had been certified by with the arrangement, were the1984 SNT-TC-1A regarding
company A without examination in this compensating both the interruption of NDT duties while
case? nonemployee and the certifying continuing to work for the same
company? employer. However, the employer
Response must be satisfied with the
Yes, if addressed in employers Response proficiency of any individual at any
written practice. Reference Inquiry 87-2. level to handle work tasks. The
1. Yes. employer has direct knowledge of
2. No. the employees prior performance
Inquiry 01-14 3. No. and can best judge the need for
reexamination as a function of
The wording of Paragraph 4.3.1 of
duration of interrupted NDT
SNT-TC-1A (which reads the same in the
1996 and 2001 editions) is not clear and
Inquiry 02-2 service.
is inconsistent with the body of Is it the intent of SNT-TC-1A (2001)
knowledge. Please advise of the official Paragraph 10.2 to recommend periodic Inquiry 03-2
ASNT position on the following. testing with test props with at least one
1. Is it the intent of Paragraph 4.3.1 of flawed specimen or are other means of May an NDT Level III develop,
SNT-TC-1A that a Level I receive technical performance evaluation qualify and approve NDT procedures,
direct supervision from a Level II acceptable, for example, monitoring an and establish and approve techniques in
or Level III by their presence inspector performing an official the methods in which not certified?
during the examination, production inspection?
interpretation, evaluation and Response
reporting of NDT test results? Response No, see the response to Inquiry 90-1,
2. According to the recommended The means for periodic technical Part 2 and Inquiry 10-5.
training listed in SNT-TC-1A, a performance evaluation should be
Level I individual does not receive
training on discontinuities,
described in the employers written Inquiry 04-1
practice. Note that the evaluation of
interpretation and evaluation in technical performance should consist of 1. Is it the intent of Paragraph 1.4 that
most NDT methods such as PT, RT, not only monitoring the proper an employer can modify the
UT and VT. How could a Level I application of technique, but also the Guidelines of SNT-TC-1A to the
individual perform the functions of ability to recognize relevant indications extent that Level II and Level III
interpretation and evaluation and evaluate those indications against the NDT personnel can be certified
authorized in Paragraph 4.3.1 even employers acceptance criteria. without any examinations if written
with the presence of a Level II or this way in the written practice?
III? 2. What are the limits that are
Inquiry 03-1 intended regarding how much the
Response employer can deviate from
1. Regarding SNT-TC-1A (1984)
It is the intent of 4.3.1 that the Level I Paragraph 9.7.1, what is considered SNT-TC-1A as written? If no limits
should receive the necessary instruction proper evidence of continuing are given, the employer can change
or supervision from a certified NDT satisfactory performance? the entire context of SNT-TC-1A to
Level II or Level III individual. The 2. Does this mean the certified eliminate all certification exams. Is
extent of said instruction or supervision individual shall maintain that the intent?
should be sufficient to perform the tasks documentation of satisfactory
required as determined by the responsible performance? Response
party. 3. How often should performance be 1. No. The provisions of Paragraph
documented? 1.4 allow modification of the
4. CP-189 (1991) indicates suspension detailed recommendations; it is not
Inquiry 02-1 should occur if duties are not intended to allow elimination of the
An interpretation of SNT-TC-1A performed during any consecutive basic provisions of the document.
(2001) Paragraph 2.1.14 is requested. 12-month period (Sec. 7.2). Is this 2. No. Paragraph 9.2. requires
The paragraph states that an employer implied in SNT-TC-1A? certification in accordance with
writes a written practice for the Section 8, Examinations as
qualification and certification of their Response described in the employers written
employees. However, Inquiry 83-7 1. Please reference Inquiry 91-4 practice.
suggests that employers can certify Question 2.
qualified nonemployees, while Inquiry

22 Interpreting SNT-TC-1A
General Comments: 2. If so, how should an employer There is no other technician with this
SNT-TC-1A allows for modification document that training hours meet trainee on the job. It takes 8 hours to
of detailed recommendations as the recommended hours listed in complete the job. How many hours of
necessary to meet particular needs. The Tables 6.3.1A and 6.3.1B so they Work Experience can be claimed?
intent is that there be a technical can comply with the satisfactory
rationale to support such modification. completion requirements required Response
Elimination of requirements, such as by Paragraph 9.4.4? None. Paragraph 2.1.8 defines
training, experience and examination, Experience as work activities
goes beyond modification of detailed Response accomplished in a specific NDT method
requirements. 1. See Inquiry 84-4, response 1. under the direction of qualified
Inquiry 84-4 addresses home-study supervision including the performance of
(correspondence) courses, but the the NDT method and related
Inquiry 04-2 response is appropriate for both activities .
1. Is it the intent of paragraph 12.1.1 computer and Web-based training.
that individuals who are re-certified 2. See Inquiry 84-4, response 2.
based on continuing satisfactory
Inquiry 07-5
technical performance, must pass When providing third-party Level III
a new practical examination?
Inquiry 07-2 services to clients who are operating in
2. May a Level I or II individual be Per the 2001 edition of SNT-TC-1A, accordance with SNT-TC-1A, may an
re-certified, based on continuing Paragraphs 6.3.2.1 through 6.3.2.3, may ASNT NDT Level III both provide the
satisfactory technical performance experience earned as a limited Level II training and administer qualification
without taking a new practical for the prescribed period of experience examinations to those clients personnel?
examination? time qualify a person to sit for the ASNT
NDT Level III exam in that test method? Response
Response Yes.
1. No. See Inquiry 91-4 Question 2. Response
2. Yes. SNT-TC-1A provides the user No response provided; this question
sufficient latitude under Paragraph is beyond the scope of SNT-TC-1A. The Inquiry 07-6
9.7.1 to identify specifically how ASNT NDT Level III program is a Is it the intent of SNT-TC-1A that
they would evaluate evidence of third-party certification program providers of third-party training and
continuing satisfactory governed by the Certification examination services (as permitted by
performance. The requirements Management Council, not SNT-TC-1A. Paragraphs 7.4 and 8.1.5 respectively) be
should be documented in the Any inquiries about the ASNT NDT accredited by some third-party body?
employers written practice. Level III program should be addressed to
the Certification Management Council Response
c/o the Senior Manager, ASNT Technical
Inquiry 05-1 Services Department.
No. Meeting the employers written
practice requirements is all that is
Paragraph 8.1.3 states Examinations recommended in these paragraphs.
administered for qualification should
result in a passing grade of at least 80
Inquiry 07-3
percent, but if the employers written With regard to the 2006 edition of Inquiry 08-1
practice states that each examination SNT-TC-1A, Table 6.3.1A, if my UT
With reference to Table 6.3.1A, if a
must achieve 70 percent or more, and candidate has completed training and
trainee is being qualified in only one
does not require an 80 percent testing requirements per SNT-TC-1A
method, which would be the total
composite, is this acceptable? 2006 and has completed 740 hours of
experience hours for PT Level I for
intern experience with UT under
qualification and certification?
Response supervision, how do we use the Total
1. 70 hours (work experience in the
No. See Inquiry 99-3. Hours in NDT column to complete the
method)
UT Level II qualification/certification
2. 130 hours (70 hours of work
Note to the Inquirer process? It appears that without any
experience in the method plus
other experience, this UT candidate
The SNT-TC-1A Interpretation Panel 60 hours in NDT)
would have to accumulate a total of
reviewed this question and agreed with 3. 200 hours (70 hours of work
1600 hours per note 1.0 if they were
the original response. experience in the method plus
going directly to Level II in only the UT
130 hours in NDT)
method. Is this correct?
Inquiry 07-1 Response
Response
Per the 2001 edition of SNT-TC-1A, For PT, Table 6.3.1A indicates that
Yes.
Paragraphs 7.1, 7.2, and 9.4.4, and 130 hours are required in NDT, 70 hours
Tables 6.3.1A and 6.3.1B: of which must be in PT. The additional
1. Can computer or Web-based NDT Inquiry 07-4 60 hours in NDT may also be acquired
training with associated electronic in the PT method or may be acquired in
quizzes be used to satisfy the Regarding the 2001 edition of any other method.
training requirements described in SNT-TC-1A, Paragraphs 2.1.8 and 4.2:
Paragraphs 7.1 and 7.2? A trainee (uncertified technician) gets
assigned to go and perform some NDT.

Interpreting SNT-TC-1A 23
Inquiry 08-2 methods other than those in which
he or she is certified?
Response

Per the 2001 edition of SNT-TC-1A, a The cited sentence allows appropriate
Level II examiner is certified in PT, MT experience in other NDT methods to be
Response used to modify the in applicable NDT
and VT and has been approved as
capable of distinguishing and differen- 1. This question refers to two separate method experience requirements cited in
tiating contrast among colors according issues. the main paragraphs, if so defined in the
to Ishihara standard plates, as determined a. Can an NDT Level III sign off employers written practice.
by the written practice. Does this person on certifications in methods for
which he is not qualified? Yes.
also require approval by a shades of gray
Signing off on certification is Inquiry 09-4
acuity examination to be qualified in RT
to meet the requirements of Paragraph covered by Section 9.0, What qualification requirements are
8.2.2? Certification Record, and necessary to provide NDT training that
Paragraph 9.4.9 states that a will meet the guidelines found in
Response persons certification record must SNT-TC-1A Section 7.0, Training?
have the signature of the
Yes. See Inquiry 01-11. Paragraph Level III who verified the Response
8.2.2 allows the employer to determine qualifications of a candidate for
the method of testing for color SNT-TC-1A does not address the
certification. It does not require
differentiation or gray shade qualification of providers of NDT
that this Level III be certified in
differentiation. Whether to test for color training.
the applicable test methods. See
differentiation or gray shade Inquiry 90-1 Part 1.
differentiation is determined by which is b. Can an NDT Level III develop Inquiry 10-1
appropriate for the method the individual and approve the training and
is being certified in. examination program for NDT Can Paragraph 1.4 in SNT-TC-1A be
methods he is not qualified in? interpreted to allow an employers
No. Paragraph 4.3.3 states that written practice to restrict or limit the
Inquiry 08-3 the NDT Level III should be function of an NDT Level III to dye
Per the 2001 edition of SNT-TC-1A, an capable of training and penetrant testing applications, and by
MT examiner has been approved in the examining NDT Level I and II doing so, the NDT Level III would not
capability of distinguishing and personnel for certification in be required to be examined for general
differentiating contrast among colors those methods for which the knowledge in other methods?
according to Ishihara standard plates. Level III holds certification. See
Does this person need to be tested in Inquiry 90-1 Part 2. Response
shades of gray acuity, if the MT 2. Determining industry practice is not See Inquiry 88-1. The employer may
procedure uses gray magnetic particles, within the scope of SNT-TC-1A. restrict or limit the function of an NDT
to meet the requirements of Level III. Such limitation does not alter
Paragraph 8.2.2? the requirements of the Basic
Inquiry 09-2 examination for the Level III.
Response Should NDT Level I technicians be
allowed to make the final determination
No. See Inquiry 08-2.
as to whether a production part is
Inquiry 10-2
accepted or rejected and then sign off on Paragraph 8.8.3.2 states A valid
Inquiry 08-4 the production order paperwork if they endorsement of ASNT Level III
Is it permissible to count a 40-hour follow a step-by-step procedure certificate fulfills the examination criteria
radiation safety training course as part of developed by a Level III? for 8.8.1 (Basic examination) and 8.8.2
the 80 hours of Level II RT training (Method examination) for each
recommended in Tables 6.3.1A and Response applicable NDT method. Has it been
6.3.1B? Level I personnel may accept or reject implied that an ASNT NDT Level III is
parts according to written instructions not required to take the employers
Response and record results. Reporting the final examination in order to become NDT
results requires a Level II or III. Level III for the employer?
No.
Response
Inquiry 09-1 Inquiry 09-3 The cited reference in the first
1. With regard to NDT Level IIIs Paragraphs 6.3.2.1 through 6.3.2.3 paragraph should be 8.8.4 and it only
signing off on certification after describe the eligibility requirements for applies to the Basic and Method
successful completion of trainees NDT Level III, all of which require some examinations. The Specific examination
examinations, is it the intention that experience time in the applicable test requirements for each method (8.8.3)
the NDT Level III must be certified method(s). Directly below that paragraph may be addressed in two ways for an
in the method for which he or she is is the following sentence: The above ASNT Level III in the method;
signing off as per SNT-TC-1A Level III requirements may be partially examination or documented evidence of
Paragraph 4.3.3? replaced by experience as a certified experience for both the preparation of
2. Is it commonly accepted in the NDT Level II or by assignments at least NDT procedures to code, standards or
industry that an NDT Level III can comparable to NDT Level II as defined specification and the evaluation of test
sign off on certifications for in the employers written practice. What results.
is the intent of this sentence?

24 Interpreting SNT-TC-1A
Inquiry 10-3 Question Response

1. For Limited Level II certification in 1. Does it mean that all NDT No. Self-certification is not addressed
UT A-scan Thickness, Table 6.3.1C procedures/standard operating by SNT-TC-1A but self-declaration of
shows the technicians starting procedures (SOP) should be qualification does not meet the
point as being a trainee. Does this prepared by an NDT Level III? requirement of SNT-TC-1A. The
mean that personnel can go directly 2. Could an NDT Level II prepare a objective evidence is required as
from trainee to Limited Level II specific procedure based on the described in the employers written
without having held a Level I UT related standard or specification? practice and should include evidence of
certification? education, training, experience and
2. Can personnel that have met the UT Example appropriate examinations.
Level I requirements shown in The NDT Level I prepares NDT
Table 6.3.1A (40 hours of training, procedures for ferromagnetic connection Inquiry 11-1
210 hours of UT experience and inspection based on API RP7G and API
400 total hours of total NDT Spec 7 and all procedures actually With regard to Paragraphs 2.1.8, 4.2,
experience) be automatically certi- adopted from the referenced and 4.3 of the 2006 edition of
fied as Limited Level II in both specifications. SNT-TC-1A:
Digital and A-scan Thickness since 3. Could the director of the company 1. May an NDT trainee gain experi-
they have exceeded the require- (inspection agency) approve this ence hours while working under the
ments shown in Table 6.3.1 C for SOP, or direct supervision of a Level I in
those certifications? 4. Should this SOP be reviewed and the method?
approved by the NDT Level III? 2. Are there any circumstances that
Response would allow NDT trainees or NDT
Response Level I technicians to progress to
1. Yes the next certification level without
2. No, the body of knowledge require- 1. No. ever having gained actual field
ments as described in ANSI/ASNT 2. 3. 4.The scope of SNT-TC-1A is experience working with NDT
CP-105 is different for UT Level I limited to guidelines for the qualifi- Level II or Level III technicians in
and UT Thickness. The written cation and certification of NDT the method?
practice should address any personnel. The capability of devel-
thickness specific training, equip- oping, qualifying and approving Response
ment, codes, experience, etc., nec- procedure is a qualification for
essary for thickness gaging job Level IIIs. This does not preclude 1. See Inquiry 87-1. Yes, provided the
performance not addressed in the individuals who are not Level IIIs Level I receives the necessary
UT Level I training. from also having some or all of instructions or supervision from a
those skills. SNT-TC-1A does not certified Level II or III individual.
restrict employers from using indi- 2. No. As stated in Paragraph 2.1.8,
Inquiry 10-4 viduals he/she feels are qualified experience can only be gained
May an employer appoint directly an for doing those tasks. while working under the direction
EN 473 Level III as employers NDT of qualified supervision.
Level III after defined in employers
Inquiry 10-6
written practice to sign the certificates Inquiry 11-2
according to SNT-TC-1A in order to Is it the intent of SNT-TC-1A that the
verify qualification of candidate for hour method for achieving the necessary 1. Do the guidelines described in
certification? personnel experience in an NDE method Paragraph 8.5 of the 2006 edition
is equivalent to the month method for all of SNT-TC-1A fully fill the guide-
Response applicable current and previous editions? lines described in Section 10?
2. Do the two guidelines need to be
The employer may use the examina- done separately or can they be done
tion results that he/she has determined Response
together?
meet the requirement of the written prac- A person whose documented
tice. As stated in SNT-TC-1A, Paragraph experience meets the requirements of the Response
8.1.5, the employer is responsible for table stating the requirements in hours
ensuring the examination services meet can be considered as having met the 1. Yes.
the requirements of the employers writ- experience requirements for documented 2. The provisions of Paragraphs 8.5
ten practice. Certification can only be experience based on months as defined in and 8.6 are done separately. The
issued when it has been determined that previous editions of SNT-TC-1A. Practical examination as described
all the requirements of the employers in Section 8.5 is part of the docu-
written practice have been met. mentation for initial certification.
Inquiry 10-7 The Technical Performance
Is self-certification acceptable per Evaluation as described in Section
Inquiry 10-5 SNT-TC-1A? Specifically, can a Level III 10 is intended to document contin-
As stated in the SNT-TC-1A 2006 edi- in one method certify himself in another ued satisfactory performance during
tion, Paragraph 4.0 Level of Qualifica- method as Level III without additional the certification period.
tion, 4.3.3 NDT Level III: An NDT training or examination?
Level III individual should be capable of
developing, qualifying and approving
procedure ..., etc.

Interpreting SNT-TC-1A 25
Inquiry 11-3* to meet particular needs. The intent is
that there be a technical rationale to sup-
should review the detailed recommenda-
tions presented herein and modify them,
Is recertification considered a port such modification. Elimination of as necessary, to meet particular needs.
detailed recommendation or a require- requirements, such as training, experi- Such modification may alter but shall not
ment as described in the General ence and examination, goes beyond mod- eliminate basic provisions of the program
Comment following the response for ification of detailed requirements. such as training, experience, testing and
Inquiry 04-1? recertification.
Response
Background *Note: The SNT-TC-1A Interpretation
This inquiry was answered with the
In the General Comment following the release of the 2011 edition of SNT-TC-1A Panel did not issue a formal response to
response for Inquiry 04-1 it says, which states in part in Paragraph 1.4, this inquiry since it was answered in the
SNT-TC-1A allows for modification of In developing a written practice as 2011 edition of SNT-TC-1A.
detailed recommendations as necessary required in Section 5, the employer

26 Interpreting SNT-TC-1A
Index Comparable experience, 2 (77-4),
9 (83-8), 19 (94-1), 21 (01-8)
Experience
actual work performance, 7 (81-5),
Page numbers are followed by the Composite examination grade, 20 (99-3) 23 (07-4)
Inquiry number in parentheses. Inquiries CP-105, 25 (10-3) additional experience requirements,
and responses are indexed by topic. CP-189, 22 (03-1) 8 (83-2)
Inquiries are also indexed by the source in another examination method,
paragraph or the table in Recommended D reducing requirements for a given
Practice No. SNT-TC-1A. method, 10 (85-1), 24 (09-3)
Demonstrated ability, in lieu of
examination, 15 (89-4), 17 (90-4), classroom training as substitute for,
A 1 (76-1), 6 (80-12), 10 (85-3),
18 (92-2)
Annual examination, 7 (80-15) Designated representative, 16 (90-1), 15 (89-3)
API RP76, 25 (10-5) 17 (91-4) comparable experience, 1 (77-1),
API Spec 7, 25(10-5) Digital thickness measurement 2 (77-4), 9 (83-8), 19 (94-1)
ASME Code Book, 25 (10-6) equipment, 3 (78-7) consecutive months, 17 (91-5)
ASNT NDT Level III, 23 (07-2) Documentation of satisfactory credit for experience required for lower
training employers personnel, performance, 22 (03-10) levels, 18 (93-4)
23 (07-5) defining what constitutes month,
E 8 (83-1)
B examination prior to obtaining,
Eddy current testing, 11 (85-9) 15 (89-6)
Basic examination, 7 (81-3), 25 (10-2) Educational background records, gaining simultaneously, 1 (76-1),
Body of knowledge, 25 (10-3) 5 (79-13) 1 (76-2), 3 (78-3), 4 (79-1),
Employer 5 (80-3), 6 (80-6), 10 (85-3),
C appoint Level III, 25 (10-4) 15 (89-3)
Certification (see also Examination; certification without examination, hour method, 25 (10-6)
Qualification; Recertification) 02 (04-1) hours, 19 (99-1), 23 (07-4)
by appointment, 7 (81-9), 11 (85-7), modification of guidelines, 22 (04-1) interrupted service, 4 (78-10)
15 (89-4), 16 (90-2), 18 (92-2), NDT training school as, 13 (87-2) limited Level II, 23 (07-2)
18 (93-2), 20 (01-2), 20 (01-4), what constitutes?, 1 (77-3) month method, 25 (10-6)
21 (01-7) who constitutes?, 8 (82-7) NDT-related activities, 6 (80-12)
designated representative, 16 (90-1), when NDT technicians work for need for active experience versus
17 (91-4), 21 (01-8) subsidiaries, 18 (93-3) maintaining certification,
equivalents to, 13 (87-4), 21 (01-8) EN 473 Level III, 25 (10-4) 13 (87-3), 17 (91-1)
hours, 5 (80-3) Examination 25 percent rule, 6 (80-12), 8 (82-4),
internal versus external, 12 (86-5) administration by Level 1, 10 (84-2 and 9 (83-10), 13 (87-3), 13 (87-6),
new employer, requirements satisfied 85-5) 15 (89-3)
in old job but not actually certified, administration by Level III, 19 (95-1), under supervision, 23 (07-3), 23 (07-
6 (80-12.4), 10 (84-3) 21 (01-8) 4), 25 (11-1)
nonemployees, 22 (02-1) annual defined, 7 (80-15) while working as trainee, 12 (87-1),
reinstatement without examination, ASNT-provided questions, 5 (79-2), 23 (07-4)
4 (78-10) 19 (96-1) work time, 5 (79-14 and 79-15),
restrictive, 8 (82-1) basic, 7 (81-3) 8 (83-1), 23 (07-4)
revocation after failing examination, by outside agencies, 16 (90-2) Experience verification and
18 (93-1) closed book, 2 (77-5), 14 (89-1), documentation, 2 (77-10), 14 (88-2)
sequence for completing requirements, 14 (89-2)
11 (85-6) demonstrated ability in lieu of, F
subcontracting, 1 (77-3) 15 (89-4), 17 (90-4), 18 (92-2),
21 (01-13) Failing grade, 19 (96-2), 20 (99-3)
transferring from earlier SNT-TC-1A
editions, 1 (77-1), 2 (77-6), direct supervision/monitoring,
2 (77-12) G
3 (78-2), 7 (80-14), 10 (85-2),
12 (86-7), 19 (96-1) employers exam, 24 (10-1), 24 (10-2) General examination, 7 (81-3)
without examination, 22 (04-1) failing grade, 19 (96-2) number of questions, 8 (82-6)
Classroom training, prorating, failure, revocation of certification after, weight factor, 11 (85-8)
7 (81-16) 18 (93-1) Grandfathering, 9 (83-4)
Closed book examination, 2 (77-5), general, 7 (81-3), 8 (82-6) Guidelines, deviating from, 6 (80-8)
14 (89-1), 14 (89-2) Level III requirement, 19 (96-3)
Color vision-deficient inspectors, method, 7 (81-3) H, I
12 (86-1) modifying number of questions, High school requirements, 19 (99-1),
Color vision examination, 4 (78-11), 6 (80-4) 19 (99-2), 20 (01-3)
20 (01-6), 21 (01-11) need for, 16 (90-2) Home-study courses, 9 (83-9), 10 (84-4),
annual basis or upon recertification, practical, 5 (80-2), 7 (81-3) 23 (07-1)
7 (81-1), 8 (83-3) prior to obtaining experience, 15 (89-6) Inquiry guidelines, iii, 31
Ishihara color chart suitable for, subcontracting, 1 (77-3) Interrupted service, 4 (78-10)
7 (81-15), 9 (83-6), 24 (08-2) Examination questions, 14 (89-1), Ishihara color chart, 7 (81-15), 9 (83-6),
mandatory, 20 (01-5) 14 (89-2), 15 (89-5) 21 (01-11), 24 (08-2), 24 (08-3)
Color vision recertification, 7 (81-1),
8 (83-3)

Interpreting SNT-TC-1A 27
J eye examination by, 4 (78-11), O
Jaeger test chart, 4 (78-11) 17 (91-3) On-the-job training, 7 (81-13)
minimum distance, 5 (79-4) general knowledge of other NDT Outside agencies, 9 (83-7)
Job termination, recertification after, methods, 16 (90-1), 17 (90-3), examination services, 16 (90-2)
13 (87-5) 24 (10-1) for Level III work, 1 (77-3), 2 (77-12),
grandfathering, 9 (83-4) 17 (91-4), 20 (00-3), 20 (01-1)
L internal versus external certification,
12 (86-5) P
Laboratory time, credit for, 5 (79-14 and limit function of, 24 (10-1)
79-15) limitation to those tested by ASNT, Paragraph 1.1, 1 (76-4)
Leak testing, 14 (88-1) 18 (93-1) Paragraph 1.2, 14 (88-2)
Level I, 1 (76-5) near-distance vision acuity examination Paragraph 1.3, 13 (87-2)
accept/reject parts 24 (09-2) administration, 4 (78-11), 17 (91-3), Paragraph 1.4, 3 (78-7), 6 (80-8),
direct supervision of, 22 (01-14), 21 (01-11) 17 (91-2), 18 (92-1), 24 (10-1),
23 (07-4), 25 (11-1) outside services, 1 (77-3), 2 (77-12), 26 (11-3)
duties and capabilities 1968 versus 17 (91-4), 20 (01-1) Paragraph 2.1, 15 (89-6)
1975, 1 (76-3) performance of Level II functions Paragraph 2.1.5, 8 (82-7), 11 (85-4),
employer certification without without being certified Level II, 13 (87-2)
examination, 22 (04-1) 4 (78-9) Paragraph 2.1.7, 11 (85-4)
field experience, 25 (11-1) self-certification, 25 (10-7) Paragraph 2.1.8, 23 (07-4), 25 (11-1)
high school requirements, 20 (01-3) self-employed consultants, 11 (85-4) Paragraph 2.1.14, 22 (02-1)
needs Level II present, 10 (84-2 and sign off on certification of others, Paragraph 3.1.1.2, 9 (83-6)
85-5), 22 (01-14) 24 (09-1) Paragraph 4.0, 20 (99-4), 25 (10-5)
requalification, 1 (76-2) train and examine others in different Paragraph 4.1, 3 (78-7), 20 (99-4)
trainee experience credit, 12 (87-1), methods, 24 (09-1) Paragraph 4.1(a) (1968), 1 (76-3)
23 (07-4), 23 (08-1) without Level II experience, 9 (83-8) Paragraph 4.1 (1975), 8 (82-1), 14 (88-1)
Level II Level III examination (see also General Paragraph 4.2, 12-13 (87-1), 23 (07-4),
comparable experience, 9 (83-8), examination; Practical 25 (11-1)
19 (94-1) examination; Specific examination) Paragraph 4.3, 16 (89-8), 25 (11-1)
direct, 23 (07-3) administrative, 20 (99-4) Paragraph 4.3(a) (1975), 1 (76-3)
employer certification without ASNT-provided questions, 5 (79-2), Paragraph 4.3(c), 3 (77-13), 5 (79-2),
examination, 22 (04-1) 19 (96-1) 6 (80-9)
establishment of specific techniques, passing grades, 8 (82-3) Paragraph 4.3.1, 12 (87-1), 22 (01-14)
16 (89-8) questions, 3 (77-13) Paragraph 4.3.2, 12 (86-2), 12 (87-1)
field experience, 25 (11-1) waiver of, 6 (80-9), 19 (96-3), Paragraph 4.3.3, 16 (90-1), 25 (10-5)
hours needed for direct Level II, 20 (01-4), 21 (01-8), 21 (01-13) Paragraph 4.3.3 (1988), 17 (90-3),
23 (07-3) weight factor, 11 (85-8) 20 (01-4)
in inspection: Level III supervision Level III Program Committee, Paragraph 5, 1 (76-4)
needed, 12 (86-2) 16 (89-10) Paragraph 5.1, 9 (83-7), 12 (86-2),
limited, 23 (07-2) Limited Level III, 25 (10-3) 13 (87-2), 15 (89-6)
practical examination, 6 (80-7) Liquid penetrant testing, 6 (80-4) Paragraph 6, 8 (82-1), 14 (88-1)
prepare procedures, 25 (10-5) by color vision-deficient inspectors, Paragraph 6.0 (1985), 13 (87-3)
reexamination, 3 (78-1), 12 (86-3) 12 (86-1) Paragraph 6.2.1, 1 (76-1), 1 (76-2),
requalification, 1 (76-2) 2 (77-4)
Specific examination, 15 (89-5) M Paragraph 6.2.1 (1975), 10 (85-3)
total hours in NDT, 23 (07-3) Paragraph 6.2.5, 2 (77-4)
training hours, 24 (08-4) Magnetic particle testing, 11 (85-9) Paragraph 6.3, 2 (77-4), 6 (80-9),
Level III by color vision-deficient inspectors, 13 (87-5), 20 (01-4)
administration of examinations, 12 (86-1) Paragraph 6.3.1, 17 (91-5)
19 (95-1) Method examination, 7 (81-3), 24 (10-2) Paragraph 6.3.1(b) (1975), 2 (77-4)
approval of techniques, 22 (03-2) Minimum passing grade, 25 (10-4) Paragraph 6.3.1(c) (1975), 2 (77-4)
certification by appointment, 7 (81-9), MT method, 10 (85-3), 15 (89-3), Paragraph 6.3.1(d) (1975), 2 (77-4)
11 (85-7), 15 (89-4), 16 (90-2), 18 (93-4), 24 (08-2), 24 (08-3) Paragraph 6.3.2, 13 (87-3), 15 (89-4),
17 (90-4), 18 (92-2), 18 (93-2), Multiple codes, specifications and 17 (91-1)
19 (96-3), 20 (01-2), 20 (01-4), standards, 5 (79-13) Paragraph 6.3.2 (1980), 8 (81-16)
21 (01-7), 21 (01-8) Paragraph 6.3.2(a) (1975), 2 (77-4)
certification of other levels by, N Paragraph 6.3.2.1, 9 (83-8), 13 (87-3),
16 (90-1) National Certification Board, 16 (89-10) 19 (94-1), 23 (07-2), 24 (09-3)
certification of others in different NDT-related activities, 6 (80-12), Paragraph 6.3.2.2, 9 (83-8), 13 (87-3),
methods, 24 (09-1) 10 (85-1) 23 (07-2), 24 (09-3)
comparable experience, 2 (77-4), NDT training school, 13 (87-2) Paragraph 6.3.2.3, 9 (83-8), 13 (87-3),
9 (83-8) Near-distance vision acuity examination, 23 (07-2), 24 (09-3)
composite grades, 2 (77-8) by Level III, 4 (78-11), 17 (91-3) Paragraph 7, 10 (84-4)
develop NDT procedures, 22 (03-2), Nondestructive testing Paragraph 7.1 (1980), 7 (81-13),
25 (10-5) subcontracting, 1 (77-3) 23 (07-1)
equivalents to, 13 (87-4) Paragraph 7.1, 23 (07-1)
Paragraph 7.2, 23 (07-1)

28 Interpreting SNT-TC-1A
Paragraph 7.4, 23 (07-5) Paragraph 9.7, 4 (78-9) Records maintenance, 4 (79-1), 20 (00-1),
Paragraph 8, 10 (84-4) Paragraph 9.7.1, 17 (91-4), 22 (03-1), 21 (01-12)
Paragraph 8.1, 3 (78-1), 17 (91-3) 23 (04-2) Reexamination, 18 (93-1)
Paragraph 8.1.1, 21 (01-8) Paragraph 9.7.1(a), 4 (78-10) need for, 3 (78-1), 3 (78-2), 7 (80-14),
Paragraph 8.1.1.2, 7 (81-15) Paragraph 9.7.3, 4 (78-10), 18 (93-1) 12 (86-3), 23 (04-2)
Paragraph 8.1.1.2 (1975), 12 (86-1) Paragraph 9.12, 9 (83-7), 13 (87-4) Requalification, 1 (76-2)
Paragraph 8.1.1.2 (1980), 12 (86-1) Paragraph 10.2, 2 (77-10), 3 (78-4), Restrictive certification/qualification,
Paragraph 8.1.1(4) (1980), 7 (80-15) 10 (84-3), 12 (86-3), 14 (88-2), 8 (82-1)
Paragraph 8.1.3, (05-1) 18 (92-1), 21 (01-13), 22 (02-2) RT method, 9 (83-11)
Paragraph 8.1.3.2 (1980), 9 (83-5) Paragraph 10.2(a), 3 (78-4), 4 (78-10) training, 24 (08-4)
Paragraph 8.1.4.4 (1980), 8 (83-3) Paragraph 10.2(b), 3 (78-4), 4 (78-10),
Paragraph 8.1.5, 23 (07-5), 25 (10-4) 8 (83-2) S
Paragraph 8.2, 4 (78-9), 21 (01-11) Paragraph 10.2(c), 3 (78-4), 4 (78-10), Self-certification, 25 (10-7)
Paragraph 8.2(a1), 4 (78-11), 5 (79-4) 8 (83-2) Self-employed consultants, as Level III,
Paragraph 8.2(a2), 4 (78-11), 7 (81-1) Paragraph 10.2.3, 13 (87-5) 11 (85-4)
Paragraph 8.2(a2) (1975), 12 (86-1) Paragraph 12.1.1, 23 (04-2) Self-training, 9 (83-9)
Paragraph 8.2(a3), 4 (78-11) Paragraph 12.1.11, 23 (04-2) Sequence of requirements, 11 (85-6)
Paragraph 8.2(c2), 5 (79-13) Percentile weight factors (see Weight 70 percent grade, 19 (96-2)
Paragraph 8.2(d), 4 (78-11) factors) Shades of gray acuity examination,
Paragraph 8.2.2, 21 (01-9), 24 (08-2), 25 percent rule, 6 (80-12), 8 (82-4), 24 (08-2), 24 (08-3)
24 (08-3) 9 (83-10), 13 (87-3), 13 (87-6), Shall defined, 15 (89-7), 23 (05-1)
Paragraph 8.3.3 (1980), 9 (83-11) 15 (89-3) Should defined, 15 (89-7)
Paragraph 8.3.3.1(e), 14 (88-1) Periodic testing, 22 (02-2) Simultaneous experience credit, 1 (76-1),
Paragraph 8.3.3.2(c) (1980), 9 (83-5) Personnel experience, 25 (10-6) 1 (76-2), 3 (78-3), 4 (79-1),
Paragraph 8.3.4, 20 (01-4) hour method, 25 (10-6) 5 (80-3), 6 (80-6), 10 (85-3),
Paragraph 8.4, 5 (79-2) month method, 25 (10-6) 15 (89-3)
Paragraph 8.4.2 (1980), 9 (83-11) Practical examination, 5 (80-2), 7 (81-3), SNT-TC-1A (see also Level I; Level II;
Paragraph 8.5 (1975), 2 (77-5), 25 (11-2) Level III; specific paragraphs and
14 (89-2), 25 (11-2) Level II, 6 (80-7) tables)
Paragraph 8.5.1(c), 5 (80-2) weight factor, 11 (85-8) deviating from guidelines, 6 (80-8),
Paragraph 8.5.2, 3 (77-13), 4 (78-9) Prior certification, 3 (78-4), 18 (92-1), 22 (04-1)
Paragraph 8.5.2(c), 6 (80-7) 21 (01-8) inquiry guidelines, iii, 26
Paragraph 8.5.3, 2 (77-8) PT method, 10 (85-3), 15 (89-3), should and shall defined,
Paragraph 8.5.3(a), 3 (77-13), 5 (79-2) 17 (91-5), 24 (08-2) 15 (89-7)
Paragraph 8.5.3(a) (1975), 8 (82-6) SNT-TC-1A Interpretation Panel, iii,
Paragraph 8.5.3(c), 11 (85-8) Q 18 (93-3)
Paragraph 8.5.4, 6 (80-9) Qualification (see also Certification) Specific examination
Paragraph 8.5.4 (1975), 7 (80-14) demonstrated ability in lieu of each method, 24 (10-2)
Paragraph 8.6, 2 (77-8), 4 (78-9), examination, 15 (89-4), 17 (90-4), question content, 14 (89-1), 15 (89-5)
25 (11-2) 18 (92-2) weight factor, 3 (78-6), 11 (85-8)
Paragraph 8.6.3, 2 (77-8), 3 (78-6) restrictive, 8 (82-1) Subcontract, 1 (77-3)
Paragraph 8.6.3(c2), 11 (85-8) subdivision of basic levels of, Subsidiaries, 18 (93-3)
Paragraph 8.6.4, 2 (77-8) 14 (88-1), 20 (99-4) Supervisory personnel qualification,
Paragraph 8.8, 17 (90-4), 18 (93-2) supervisory personnel, 6 (80-6) 6 (80-6)
Paragraph 8.8.1, 24 (10-2) transferring from earlier SNT-TC-1A
Paragraph 8.8.2, 24 (10-2) editions, 1 (77-1), 2 (77-6), 3 (78-2), T
Paragraph 8.8.3.2, 24 (10-2) 7 (80-14), 10 (85-2), 12 (86-7),
Paragraph 8.8.4, 24 (10-2) Table 6.2.1A, 1 (76-1), 1 (76-2), 3 (78-3),
19 (96-1) 5 (79-14 and 79-15), 6 (80-6),
Paragraph 8.10, 18 (93-1) Qualification records, 7 (81-12)
Paragraph 9.1, 1 (77-3) 6 (80-12), 7 (81-5), 8 (82-1),
Paragraph 9.2, 22 (04-1) 8 (82-4), 14 (88-1)
R Table 6.3.1, 6 (80-12), 7 (81-16), 8 (82-4),
Paragraph 9.3, 11 (85-8), 13 (87-5),
18 (92-1) Radiography, 9 (83-6), 21 (01-9) 8 (82-7), 9 (83-10), 10 (85-1),
Paragraph 9.4, 1 (77-3), 2 (77-8), Recertification (see also Certification), 13 (87-3), 14 (88-1), 17 (91-5),
21 (01-12) 2 (77-6), 3 (78-4), 4 (78-10), 19 (94-1), 19 (94-2), 25 (10-3)
Paragraph 9.4.4, 23 (07-1) 18 (92-1), 26 (11-3) Table 6.3.1A, 23 (07-1), 23 (07-3),
Paragraph 9.4.9, 24 (09-1) after job termination, 13 (87-5) 23 (08-1), 24 (08-3), 24 (08-4),
Paragraph 9.5, 1 (77-3) applicable edition, 1 (77-1), 3 (78-2), 25 (10-3)
Paragraph 9.5 (1988), 16 (90-2) 7 (80-14), 10 (84-1) Table 6.3.1B, 23 (07-1), 24 (08-4)
Paragraph 9.5.1(a) (1996), 21 (01-10) continuing satisfactory performance Table 6.3.1C, 25 (10-3)
Paragraph 9.6, 2 (77-10), 14 (88-2) and, 17 (91-4), 19 (96-1), 21 (01-10), Technical and Education Council, iii,
Paragraph 9.6(g), 17 (90-4) 22 (03-1) 18 (93-3)
Paragraph 9.6.1(c), 5 (79-13) need for, 9 (83-5) Technical Performance Evaluation,
Paragraph 9.6.1(f), 5 (80-2), 6 (80-9), requirements, 26 (11-3) 25 (11-2)
7 (81-12) Recommended Practice No. SNT-TC-1A Thickness, 25 (10-3)
Paragraph 9.6.1.6, 12 (86-3) (see SNT-TC-1A) A-scan, 25 (10-3)
Paragraph 9.6.1.10, 16 (90-1), 17 (91-4) Limited Level III, 25 (10-3)

Interpreting SNT-TC-1A 29
trainee, experience credit, 12 (87-1), waiver of requirement, 16 (89-11) W
23 (07-4), 23 (08-1) Training courses, 9 (83-9) Waive training, 16 (89-11)
Trainer requirements, 24 (09-4) 25 percent rule, 6 (80-12), 8 (82-4), Web based training, 23 (07-1)
Training 9 (83-10), 13 (87-3), 13 (87-6), Weight factors, 3 (78-6)
additional training requirements, 15 (89-3) for different tests, 9 (83-11),
8 (83-2) 11 (85-8)
classroom training prorating, U, V Work time experience (see Experience)
7 (81-16) Unsupervised work experience, 23 (07-4) Written practice, 21 (01-8), 22 (02-1)
employers personnel, 23 (07-5) UT A-scan Thickness, 25 (10-3) two, 20 (00-2), 25 (10-3)
home-study courses, 9 (83-9), UT method, 9 (83-11), 19 (94-2), employers, 23 (07-5), 25 (10-4),
10 (84-4) 23 (07-3) 25 (10-7), 26 (11-3)
on-the-job training, 7 (81-13) UT Thickness, 25 (10-3) limit function of NDT Level III,
requirements, 10 (84-3), 19 (99-1), Vision acuity examination, 5 (79-4) 24 (10-1)
24 (08-4), 24 (09-4) by Level III, 4 (78-11), 17 (91-3) evidence of education, 25 (10-7)
subcontracting, 1 (77-3) Visual examination, 17 (91-2), 20 (01-5),
third party, 23 (07-5) 20 (01-6), 24 (08-2), 24 (08-3)

30 Interpreting SNT-TC-1A
Sample Inquiry to the SNT-TC-1A Interpretation Panel

Use the form below when providing Inquiries addressing several aspects of All inquiries should be sent to:
necessary information for your inquiries SNT-TC-1A may be returned by the panel
to the SNT-TC-1A Interpretation Panel. with questions for clarification. All SNT-TC-1A Interpretation Panel
Specific questions should be limited to inquiries must be typewritten or neatly Chair
a single recommendation of SNT-TC-1A. printed. ASNT Headquarters
It is important that your inquiry include A typical inquiry appears as follows. Technical Services Department
the year of the recommended practice that 1711 Arlingate Lane
you are using, and that documents para- Date: 1 January 2011 PO Box 28518
graph numbers for the text that applies to 2006 SNT-TC-1A, Paragraph 1.2 Columbus, OH 43228-0518
your companys specific question.
You may attach your own interpretation May an employer deviate from the
or a summary of your companys position guidelines of the 2006 edition of
to aid the panel in responding to your SNT-TC-1A, Paragraph 1.2, in order to
inquiry. meet the employers specific needs?

SNT-TC-1A Interpretation Panel Chair


ASNT Headquarters
Technical Services Department
1711 Arlingate Lane
PO Box 28518
Columbus, OH 43228-0518

SNT-TC-1A INQUIRY

Name ________________________________ Phone _______________________________________

Address ______________________________ State _____________________ ZIP ___________

Date _________________________________ SNT-TC-1A Edition _________ Paragraph ______

Inquiry _________________________________________________________________________________

_________________________________________________________________________________________

_________________________________________________________________________________________

_________________________________________________________________________________________

_________________________________________________________________________________________

_________________________________________________________________________________________

_________________________________________________________________________________________

_________________________________________________________________________________________

_________________________________________________________________________________________

Interpreting SNT-TC-1A 31
The American Society for ISBN: 978-1-57117-103-0
Nondestructive Testing Catalog No: 2040

You might also like