The equipment for a 2.2 Mw hydro plant, and for the process plant
began to arrive in early 1982.
3
Draftfor discussion only
4
Draftfor discussion only
5
Draftfor discussion only
The El Toqui power system is isolated from the regional grid system.
6
Draftfor discussion only
7
Draftfor discussion only
27%
1.500 30%
1.000 20%
500 10%
0 0%
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Diesel Hydro Wind Green %
8
Draftfor discussion only
2.500 8,0
7,7
8
7,0
7,0
2.000 6,1
6
1.500 4,7
3,9
4
3,4
1.000
2
500 1,0
0 0
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Diesel Hydro Wind River Flow - m3/sec
9
Draftfor discussion only
Last 10 Years Total Power Generation (GWh) & Green Energy (%)
GWh %
45 70%
Mill #6 & Paste Plant
62% 60%
40
55% 57% 60%
55%
35 51%
48% 50%
45% 45% 46%
30
25 40%
42
20 40 30%
38
35
15
27 28 27 29 29
26 20%
10
10%
5
0 0%
2005 2006 2007 2008 2009 2010 2011 2012 2013 2014
62% 60%
55% 57% 60%
55%
20
51%
48%
45% 46% 50%
45%
15
40%
30%
10
20%
5
10%
0 0%
2005 2006 2007 2008 2009 2010 2011 2012 2013 2014
11
Draftfor discussion only
Diesel
250
200
Total Average
150
100
Wind Farm
50
Hydraulic
0
2007 2008 2009 2010 2011 2012 2013 2014
12
Draftfor discussion only
Total Average Cost - $/MWh & Average Cost per Liter of Diesel
$/MWh $
180 1,5
160
140
120 1,0
40
20
0 0,0
2007 2008 2009 2010 2011 2012 2013 2014
$/liter Average
13
Draftfor discussion only
Tom Olsen
General Manager
14
Draftfor discussion only
15
Draftfor discussion only
16
Draftfor discussion only
17
Draftfor discussion only
19
Draftfor discussion only
20
Draftfor discussion only
21
Draftfor discussion only
Tom Olsen
General Manager
Wind Farm
Nyrstar El Toqui
22
Draftfor discussion only
23
Draftfor discussion only
24
Draftfor discussion only
25
Draftfor discussion only
General View
26
Draftfor discussion only
27
Draftfor discussion only
28
Draftfor discussion only
d. The control system for the blades is not as fast as the wind gusts
variations existing in the area. This has provoked most of the issues
reported per each one of the six units.
f. Wind range above 20 m/sec. is not common. This wind velocity never
lasts more than 8 hours.
29
Draftfor discussion only
Technical Inspection
30
Draftfor discussion only
The wind farm has a supervisory control and data acquisition (SCADA)
monitoring system in place through optic fiber. Based on the
manufactures recommendation, the preventive maintenance per unit is
performed every 6 months of operation.
31
Draftfor discussion only
32
Draftfor discussion only
3. The reduction on hours of operation per each diesel generation unit will