Professional Documents
Culture Documents
CAR
ACCESSORY
PRODUCTS
2015/2016
THE RIGHT FIT FOR EACH CAR
International
Energy stations 7
Jumper cables 8
Lifting gears 9
Workshop equipment 11
SERVICE 12
Note: For safe handling of the products please refer to the instructions in the operating manual.
3
4
BATTERY CHARGER BATTERY CHARGER
BT-BC 2 D BT-BC 4 D
ERIES ERIES
R GEL BATT R GEL BATT
PROPER FO PROPER FO
maintenance
Built-in ammeter | Overload- and fals poling- and Built-in ammeter | Overload- and fals poling- and Built-in ammeter | Overload- and fals poling- and
short circuit protection | Charging leads with sturdy, fully short circuit protection | Charging leads with sturdy, fully short circuit protection | Charging leads with sturdy, fully
insulated pole clamps | Plastic housing | Carrying handle | insulated pole clamps | Sheet steel housing | Carrying handle insulated pole clamps | Sheet steel housing | Carrying handle
All-insulated construction | ON/OFF switch
Built-in ammeter | Overload- and fals poling- and Built-in ammeter | Overload- and fals poling- and Charging automatic by a controlled microprocessor | Built-in ammeter | Overload- and fals poling- and
short circuit protection | Charging leads with sturdy, fully in- short circuit protection | Charging leads with sturdy, fully Fault diagnosis system | LED display | Charging leads with short circuit protection | Charging leads with sturdy, fully
sulated pole clamps | Sheet steel housing | Electronic charg- insulated pole clamps | Sheet steel housing | Carrying handle sturdy, fully insulated pole clamps | Overload-, voltage re- insulated pole clamps | Sheet steel housing | Turn-switch for
ing (with overloading protection) versal- and short circuit protection | Cigarette lighter jack quick and normal load and settings of the required voltage
for 12 Volt d.c. output | Especially for charge maintenance
Article number 10.508.50 Article number 10.567.00 Article number 10.022.00 Article number 10.750.20
The charging characteristic indicates the rela- For lead acid batteries For lead acid batteries For lead acid batteries, AGM batteries and gel
tionship between the charging current and the batteries
charging time. The charging characteristic is Quick charging is possible with a low charging This method is very well suited for the quick
represented in a graph by the current (A) as a current. charging and partial charging of batteries. This method is very well suited for the con-
function of the charging voltage (U). tinuous charging and so-called maintenance
It is recommended to supervise the charging of The battery can be charged without super- charging of batteries.
We work with 3 different charging characte- the battery in order to rule out overcharging. vision. When the battery is fully charged, the
ristics: charging current will be automatically regu- The battery can be charged without super-
The following battery chargers have a W char- lated to make overcharging impossible. This vision. The voltage is regulated with the help
W charging characteristic ging characteristic: method is unsuitable however for continuous of a microprocessor. Overcharging the battery
IU charging characteristic charging (maintenance charging).
is impossible.
IUoU charging characteristic BT-BC 4/1 P
The following so-called automatic battery
BT-BC 5 The following high-frequency battery chargers
chargers have an IU charging characteristic:
BT-BC 8 have an IUoU charging characteristic:
BT-BC 12 BT-BC 10 E
BT-BC 15 BT-BC 22 E BT-BC 2 D
BT-BC 30 BT-BC 4 D
BT-BC 12 D-SE
BT-BC 22 E BT-BC 30
Built-in ammeter | Overload- and fals poling- and Voltmeter and ammeter | Overload- and fals poling-
short circuit protection | Sheet steel housing | Switch for and short circuit protection | Sheet steel housing | Remote
automatic (with charging voltage limiting) and normal charging cable (3 m) with button | Charging capacity with 6 settings |
| Switch for normal and rapid charging | Electronic charging Charging voltage switch (6 V / 12 V / 24 V)
(with overloading protection)
Starting aid function 12 V | Jumper cable with fully Starting aid function 12 V | Jumper cable with fully Starting aid function 12 V | Jumper cable with fully
insulated pole clips | 12 V terminal for 10 A | Lightning with insulated pole clips | 12 V terminal for 10 A | Lighting 12 V / insulated pole clips | 12 V terminal for 10 A | Lighting 12 V /
3 white high-power LEDs | Integrated 18 bar compressor | 3 W | Integrated 18 bar compressor | Battery charging con- 3 W | Integrated 18 bar compressor | Battery charging con-
Battery charging control | 3 pcs. valve adapter kit trol | 3 pcs. valve adapter kit trol | 3 pcs. valve adapter kit
ENERGY STATIONS
7
JUMPER CABLE JUMPER CABLE JUMPER CABLE
12 V / 24 V max. 2500 ccm 3m 19.4 mm2 / 12 V / 24 V max. 2500 ccm 3m 19.4 mm2 / 12 V / 24 V max. 5500 ccm max. 3000 ccm 3.5 m
Petrol 220 A Petrol 220 A Petrol Diesel
31.4 mm2 /
350 A
Booster cable tested according to DIN 72553-16 | Booster cable tested according to DIN 72553-16 | Booster cable tested according to DIN 72553-25 |
4 all-insulated pole-pliers | Conductive material made of 4 all-insulated pole-pliers | Conductive material made of 4 all-insulated pole-pliers | Conductive material made of
19.4 mm2 aluminium | Incl. carrying bag 19.4 mm2 aluminium | Pliers with LED-lighting | Integrated 31.4 mm2 aluminium | Incl. carrying bag
surge protection | Incl. carrying bag
JUMPER CABLES
12 V / 24 V max. 5500 ccm max. 3000 ccm 3.5 m 12 V / 24 V max. 5500 ccm max. 3000 ccm 3.5 m 12 V / 24 V max. 7000 ccm max. 4000 ccm 4.5 m
Petrol Diesel Petrol Diesel Petrol Diesel
2 ball bearing castors | Support plate | Lift rod | In- 2 ball bearing castors | Support plate | 2-piece lift
tegrated safety valve against overloading | Carrying handle rod | Integrated safety valve against overloading | Extra
heavy, stable design
LIFTING GEARS
9
HYDRAULIC JACK HYDRAULIC JACK HYDRAULIC JACK
2t hmin: 181 mm hmax: 345 mm 5t hmin: 216 mm hmax: 413 mm 8t hmin: 230 mm hmax: 457 mm
Safety valve | Compact and sturdy construction Safety valve | Compact and sturdy construction Safety valve | Compact and sturdy construction
2t hmin: 277 mm hmax: 365 mm 3t hmin: 285 mm hmax: 400 mm 6t hmin: 376 mm hmax: 576 mm
Large and stable support surface | Threefold height Large and stable support surface | Fourfold height Large and stable support surface | Fivefold height
adjustment | Foldaway | 2 pieces in a kit adjustment | Foldaway adjustment | Foldaway
l/min
12 V max. 260 M 14 12.7 mm 12 V max. 18 bar 4.5 l/min. 230 V ~ 50 Hz 90 W 3700 min-1 240 mm
(1/2 Zoll)
R/L
WORKSHOP EQUIPMENT
Clockwise / counter-clockwise rotation | Set of four Pressure gauge 0 - 18 bar | 2.9 m connection ca- Handy and robust polishing machine | On/Off
drive socket inserts size 17, 19, 21 and 23 mm | Adapter ble (12 V) with cigarette lighter plug | Air hose with quick switch | Incl. 1 textile polishing hood for applying the po-
cable for connecting directly to a vehicles 12 V battery | locking-valve | 3 pcs spare adapters (water ball-, air bed-, lishing agent | Incl. 1 synthetic polishing hood for producing
Plastic case and ball adapter) a long-lasting shine
POLISHING AND SANDING MACHINE POLISHING AND SANDING MACHINE POLISHING PADS FOR POLISHING PAD- / SANDING PAPER SET
BT-PO 90 FOR BT-PO 1100/1 E AND
1 x textile polishing pad | 1x synthetic polishing pad 2 x synthetic polishing pad | 1 x foam plastic pad
| 6 x sanding discs
1 1
Article number 20.930.94 Article number 20.932.33
2 x synthetic polishing pad, sanding paper 2 x 60, 2 x 80, 1 x synthetic polishing pad, sanding paper 1 x 60, 1 x 80,
2 x 120 grains 1 x 120 grains
1 1
Article number 20.932.60 Article number 20.932.62 Article number 20.932.42 Article number 20.932.41
11
GB
We can help!
Have any questions on our products?
Want to order a spare part?
Your product no longer works as well as when you first
bought it?
Contact us!
We will be glad to offer quick and unbureaucratic help.
www isc-gmbh.info
@ info@isc-gmbh.info