The gas meter AM-G10 is designed for Maximum flow rate: Qmax = 16 m3/h
measurement of gas supplied to industrial
plants where maximum consumption of Minimum flow rate: Qmin = 0,1 m3/h
gas is equivalent to 16m3/h of air of Nominal flow rate: Qn = 10 m3/h
density of 1,2 kg/m3.
Cyclic volume: V = 5 dm3
The gas meters can be used for Max. working pressure: Pmax = 0,5 bar
measurement of:
Index max indication 99999,999 m3
Natural gas
Starting flow rate: 13 dm3/h
City gas
Weight: 6,8 kg
Propane-butane gas
Gas meter in its standard version is
equipped with pulse magnet. Pulse Pressure loss curves Typical error curves
transmitter (see photo) can be added at
any time (1imp= 0,01m3). 3.0
Average pressure loss P [mbar]
3
Error [%]
2
1
Dimensions 2.0
0
-1 EN 1359 / OIML R31
1
1.0 -2
2 EG 71/318
-3
0 4 8 12 16
Qmin
0 3
Flow rate Q (m /h)
0 4 8 12 16
1 air
2 natural gas
Exact measurement
and security
The gas meter AM-G16 is designed for Maximum flow rate: Qmax = 25 m3/h
measurement of gas supplied to industrial
plants where maximum consumption of Minimum flow rate: Qmin = 0,16 m3/h
gas is equivalent to 25m3/h of air of Nominal flow rate: Qn = 16 m3/h
density of 1,2 kg/m3.
Cyclic volume: V = 5 dm3
The gas meters can be used for Max. working pressure: Pmax = 0,5 bar
measurement of:
Index max indication 999999,99 m3
Natural gas
Starting flow rate: 13 dm3/h
City gas
Weight: 6,8 kg
Propane-butane gas
Gas meter in its standard version is
equipped with pulse magnet. Pulse Pressure loss curves Typical error curves
transmitter (see photo) can be added at
3.0
any time (1imp= 0,1m3). 3
Average pressure loss P [mbar]
Error [%]
2
1 1
Dimensions 2.0
0
2
-1 EN 1359 / OIML R31
1.0 -2
71/318/EWG
-3
0 5 10 15 20 25
Qmin
0
0 5 10 15 20 25 Flow rate Q (m3/h)
1 air
2 natural gas
Exact measurement
and security
The gas meter G25 is designed for Maximum flow rate: Qmax = 40 m3/h
measurement of gas supplied to industrial
plants where maximum consumption of Minimum flow rate: Qmin = 0,25 m3/h
gas is equivalent to 40m3/h of air of Nominal flow rate: Qn = 25 m3/h
density of 1,2 kg/m3.
Cyclic volume: V = 20 dm3
The gas meters can be used for Max. working pressure: Pmax = 0,2 bar
measurement of:
Index max indication 999999,99 m3
Natural gas
Starting flow rate: 13 dm3/h
City gas
Weight: 30 kg
Propane-butane gas
Gas meter in standard version is equipped
with pulse magnet. Pulse transmitter Pressure loss curves Typical error curves
(1imp= 0,1m3) can be added at any time.
3
3.0
Error [%]
Average pressure loss P [mbar]
2
1
Dimensions 2.0 0
1
-1 EN 1359 / OIML R31
2 -2
EG 71/318
1.0
-3
0 10 20 30 40
Qmin
3
0
Flow rate Q (m /h)
0 10 20 30 40
1 air
2 natural gas
Exact measurement
and security
The gas meter G40 is designed for Maximum flow rate: Qmax = 65 m3/h
measurement of gas supplied to industrial
Minimum flow rate: Qmin = 0,40 m3/h
plants where maximum consumption of
gas is equivalent to 65m3/h of air of Nominal flow rate: Qn = 40 m3/h
density of 1,2 kg/m3. V = 65 dm3
Cyclic volume:
The gas meters can be used for Max. working pressure: Pmax = 0,2 bar
measurement of:
Index max indication 999999,99 m3
Natural gas
Starting flow rate: 32 dm3/h
City gas
Weight: 90 kg
Propane-butane gas
Gas meter in standard version is equipped
with pulse magnet. Pulse transmitter Pressure loss curves Typical error curves
(1imp= 0,1m3) can be added at any time.
2.0 3
Avarage pressure loss P [mbar]
Error [%]
2
1.5 1
Dimensions
1 0
1.0 -1 EN 1359 / OIML R31
2
-2
71/318/EWG
0.5 -3
0 10 20 30 40 50 65
Qmin
0
10 20 30 40 50 65 Flow rate Q (m3/h)
0
1 air
2 natural gas
Exact measurement
and security
The gas meter G65 is designed for Maximum flow rate: Qmax = 100 m3/h
measurement of gas supplied to industrial
plants where maximum consumption of Minimum flow rate: Qmin = 0,65 m3/h
gas is equivalent to 100m3/h of air of Nominal flow rate: Qn = 65 m3/h
density of 1,2 kg/m3.
Cyclic volume: V = 65 dm3
The gas meters can be used for Max. working pressure: Pmax = 0,2 bar
measurement of:
Index max indication 999999,99 m3
Natural gas
Starting flow rate: 32 dm3/h
City gas
Weight: 90 kg
Propane-butane gas
Gas meter in standard version is equipped
with pulse magnet. Pulse transmitter Pressure loss curves Typical error curves
(1imp= 0,1m3) can be added at any time.
3
Error [%]
3.0
Avarage pressure loss P [mbar]
1
1
Dimensions 2.0 0
2 -1 EN 1359 / OIML R31
-2
1.0 71/318/EWG
-3
0 20 40 60 80 100
Qmin
Flow rate Q (m3/h)
0
0 20 40 60 80 100
3
Flow rate Q (m /h)
1 air
2 natural gas