DESIGN OF SHEAR REINFORCEMENT OF COLUMNS

factored axial load on column Pu kip 488


factored shear load on column Vu kip 81
compressive strength of concrete fc ksi 4
yield stress of steel fy ksi 60
capacity reduction factor-phi phi 0.7
clear cover 0.75
tie dia 0.375
column width b inch 15.00
column depth h inch 24.00
select: dia of longitudinal bars db inch 0.750
provided centre spacing of column bars inch 4.00
max size of aggregate inch 1.00
CALC U LAT I O N S
sectional area of each bar sq.inch 0.11
effective depth d inch 22.50
selected gross area of concrete sq.inch 360
nominal shear strength vc kip 71.63
allowable shear strength phi vc kip 50.14
limit phi vc/2 kip 25.07
whether extra stirrups or tie to be design yes
compute max spacing to provide min As s inch 17.60
compute max spacing= d/2 inch 11.25
governed max spacing inch 11.25
compute force carried by steel Vs kip 44.09
compute required stirrup spacing inch 6.74
governed spacing for axial and shear loads inch 6.74
spacing of ties for axial loads
a) 48 x tie dia inch 18
b) 16 x long bar inch 12
c) least dimension inch 15
governed spacing of ties for axial load only inch 12
final governed spacing inch 6.74
CHECK CODE REUIREMENT
clear spacing inch 3.25
required clear spacing as per ACI 7.6.1 1.00
required minimum size of tie 0.375
criteria for size of tie tie dia is ok