Datos Valor
Z = 0.35 zona 3
S = 1.2 suelo intermedio
Tp = 0.6
Tl = 2
hn = 10.1
Ct = 60
U = 1 v iv ienda
R_0 * = 3
Ia * = 0.8
Ip * = 0.75

08/04/2017 Ing. Ambrocio Mamani C. 4


Clculos previos Valor
R = 1.8
T = 0.16833
T < Tp
C = 2.5
R = 6

08/04/2017 Ing. Ambrocio Mamani C. 5


PESO EDIFICACION
1er Niv el = 33,788.00 kg
Losa 15,606.00
Muro 17,183.00
Alfeizer 999.00
2do Niv el = 33,788.00 kg
Losa 15,606.00
Muro 17,183.00
Alfeizer 999.00
3er Niv el = 33,788.00 kg
Losa 15,606.00
Muro 17,183.00
Alfeizer 999.00
4to Niv el = 23,330.00 kg
Losa 14,739.00
Muro 8,591.00
Alfeizer 0.00
TOTAL = 124,694.00 kg

08/04/2017 Ing. Ambrocio Mamani C. 6


FUERZA CORTANTE BASAL
V = 21,821.45 kg

DISTRIBUCION DE FUERZA CORTANTE BASAL

NIVEL H P PH PH/SUMA(PH) F=%*V

4 10.100 23,330.00 235,633.00 0.32 6,878.54


3 7.575 33,788.00 255,944.10 0.34 7,471.46
2 5.050 33,788.00 170,629.40 0.23 4,980.97
1 2.525 33,788.00 85,314.70 0.11 2,490.49
SUMA 25.25 124,694.00 747,521.20 21,821.45

08/04/2017 Ing. Ambrocio Mamani C. 7


FUERZAS SSMICAS ESFUERZOS DE CORTE
(diagramas) .

F4 = 6,878.54 kg
Q4 = 6,878.54 kg Q4 = F4

F3 = 7,471.46 kg
Q3 = 14,350.00 kg Q3 = F3 + F4

F2 = 4.980.97 kg
Q2 = 19,330.97 kg Q2 = F2 + F3 + F4

F1 = 2.490.49 kg Q1 = F1 + F2 + F3 + F4
Q1 = 21,821.46 kg

Qo = 21,821.46 kg Q0 = Q1

08/04/2017 Ing. Ambrocio Mamani C. 8


F4 = 6,878.54 kg
Q4 = 6,878.54 kg
F3 = 7,471.46 kg M4 = 17,368.31 kg-m

Q3 = 14,350.00 kg
F2 = 4.980.97 kg M3 = 53,602.06 kg-m

Q2 = 19,330.97 kg M2 = 102,412.76 kg-m


F1 = 2.490.49 kg

Q1 = 21.821.46 kg M1 = 157.511.95 kg-m

Altura entrepiso = 2.525 m.