THE ALUMINIUM ALLOY USED FOR THE MANUFACTURE OF EXTRUDED
DO NOT SCALE THIS DRAWING.
THE FOLLOWING DRAWINGS REPRESENT THE STADIUM AT LAYOUT STRUCTURAL STEEL PROFILES SHALL BE GRADE 6063 OR EQUIVALENT.
SCHEMATIC DESIGN STAGE. THE DRAWINGS MUST NOT BE USED FOR GENERAL STRUCTURAL STEEL PROFILES AND PLATES AS PER EN 10025 AND
CONSTRUCTION. HOLLOW SECTIONS AS PER EN 10210 (HOT ROLLES) ARE TO BE EMPLOYED. MEMBRANE CLADDING
THE MATERIAL OF THE MEMBRANE FOR THE ROOF IS MADE OF COATED

N
THE NOTES SHALL BE READ IN CONJUNCTION WITH THE TECHNICAL STRUCTURAL STEEL PLATES; BUILD-UP SECTIONS; CONNECTIONS; HOT FABRIC WOVEN FROM GLASS FIBRE AND COATED MESH WOVEN FROM
SPECIFICATIONS. IN CASE OF ANY DISCREPANCY THE MORE STRINGENT ROLLED SECTIONS HAVE TO BE OUT OF S355 J2 UNLESS STATED OTHERWISE. GLASS FIBRE. THE COATING IS EITHER PTFE OR FLUORINATED POLYMER;

Mecca
DOCUMENT SHALL GOVERN. FOR PLATE THICKNESS OF MORE THAN 75 MM THE STEEL GRADE SHALL BE THE MESH IS LAMINATED WITH PTFE OR ETFE FILM. THE MATERIAL OF
GRADE S355 NL. THE MEMBRANE FOR THE FACADE IS MADE OF COATED FABRIC WOVEN
DO NOT SCALE FROM DRAWINGS, ALL DIMENSIONS SHOULD BE READ OR FROM GLASS FIBRE WITH PTFE COATING.
COMPUTED. PLATES AND ROLLED MEMBERS SUBJECT TO TENSION PERPENDICULAR TO
THE PLATE DIRECTION REQUIRE APPROPRIATE THROUGH THICKNESS TENSION FABRICATION / ERECTION
UNLESS OTHERWISE NOTED ON THE DRAWINGS, DIMENSIONS ARE GIVEN PROPERTIES ('TTT'/'Z-QUALITY) AS PER EN 1993-1-10. THROUGH THICKNESS THE BASIS FOR MANUFACTURE AND EXECUTION OF THE STEEL
IN MILLIMETERS AND LEVELS IN METERS. PROPERTIES HAVE TO COMPLY WITH EN 10164 AND NEED TO BE VERIFIED STRUCTURE SHALL COMPLY WITH QCS 2014 AS WELL AS EN 1090 AND
ACCORDING TO EN 1993-1-10. RELATED CODES.
ALL CONNECTION DETAILS AND THE FINAL LAYOUT OF THE STRUCTURE FAILURE CONSEQUENCES CLASS [CC] AS PER EN 1990 TABLE B.1: CC3
CONSIDERING THE DESIGN INTENT HAVE TO BE FINALLY DESIGNED BY CAST STEEL OF GRADE G18 NiMoCr 3 6 +QT WITH IMPROVED WELDABILITY CATEGORY OF OPERATIONAL DEMANDS (SYSTEM CLASS) [SC] AS PER
AND UNDER THE RESPONSIBILITY OF THE CONTRACTOR. AND TOUGHNESS SHALL BE USED FOR ALL CLAMPS AND PARTS OF THE RING 1090-2 TABLE B.1: SC1 General Notes
CONNECTORS. CATEGORY OF PRODUCTION [PC] AS PER 1090-2 TABLE B.2: PC2 - Levels refer to QND.
LOADS EXECUTION CLASS [EXC] AS PER EN 1090-2 TABLE B.3: EXC3 - All dimensions are in millimeters, except where stated differently.
LIVE LOADS ARE IN ACCORDANCE WITH BS EN 1991 THREADED RODS (ANCHOR RODS) ARE HOT-DIP-GALVANIZED BAR SETS 8.8 AS - All dimensions of axes are referring to axes nodes in the horizontal projection in plot area.
- All levels and dimensions are to be verified by site measurements prior to execution.
WIND LOADS, TEMPERATURE LOADS AND SEISMIC LOADS ARE IN PER EN ISO 898-1, GALVANIZED AT 'NORMAL TEMPERATURE' AS PER EN ISO THE CONTRACTOR SHALL PROVIDE ALL CONNECTIONS, ATTACHMENT - Structural drawings are to be read in conjunction with the corresponding architectural
ACCORDANCE WITH QCS 2014 10684 UNLESS NOTED OTHERWISE. LUGS AND (TAKE OUT) HOLES IN THE STEELWORK REQUIRED BY OTHER drawings, fire & safety drawings, acoustical drawings and the MEP Engineer's drawings and
the written structural technical specifications.
TRADES SUBJECT TO APPROVAL BY THE STRUCTURAL DESIGNER. Refer to General Notes drawings C09-AEB-D-STA-B-ST-AL-AZ-001&002
DESIGN HIGH-STRENGTH BOLTS, NUTS AND WASHERS: BOLTS TO BE SECURED AS PER - In case of discrepancies between the architectural drawings and the structural drawings or
THE STRUCTURAL DESIGN IS IN ACORDANCE WITH QATAR BS EN 1090. BOLTS ARE HOT-DIP-GALVANIZED HIGH-STRENGTH FRICTION GRIP THE CONTRACTOR SHALL PROVIDE TEMPORARY BRACING AND the fire & safety drawings, the information in the structural and fire & safety drawings
prevail.
CONSTRUCTION SPECIFICATION QCS 2014 AND EUROCODES. BOLTS OF GRADE 8.8 OR 10.9 WITH NUTS AND WASHERS DELIVERED IN ONE SUPPORTS REQUIRED DURING ERECTION FOR THE PROPER ALIGNMENT - Architecture and MEP elements in the drawings are for information only. Please refer to
SET AS PER EN 15048-1. AND ALSO AS NECESSARY TO GIVE AND MAINTAIN PROPER STABILITY OF separate set of MEP and architecture drawings.
- Fire resistance according to fire & safety specifications.
ALL STRUCTURES.
ALL PINS TO BE OUT OF 34 CrNiMo 6+QT (Mat.-No. 1.6582). MATERIAL Structural Notes
PROPERTIES ACCORDING TO EN 10343. THE CONTRACTOR SHALL PROVIDED ALL DETAILS AND CLEATS THAT - Drawings are only valid in conjunction with the written technical specifications.
ARE REQUIRED FOR CLADDING FIXATION. - Connections and structural details are shown for approximate information purpose only at
CORROSION PROTECTION IN ACCORDANCE WITH EN ISO 12944: CORROSION SD.
- All structural steel S355 J2 as per EN 10025 unless specified otherwise.
ENVIRONMENT CLASSIFICATION C5M AND HIGH DURABILITY. FINISH PAINT THE THREADING OF THE PRESET ANCHOR BOLTS IS TO BE TESTED TO - Corrosion protection class C5M.
COLOUR AS DEFINED BY THE ARCHITECT. GUARANTEE THAT NO SLIP OF NUTS OCCURS BEFORE THE ANCHOR
FIRE RATING ACCORDING TO SPECIFICATIONS BY THE FIRE ENGINEER. BOLT MATERIAL FAILURE.
PROTECTION PROVIDED BY INTUMESCENT PAINT WITH HIGH DECORATIVE
FINISHING SHOWING HIGH STANDARD OF OF EVENESS, SMOOTHNESS AND ALL STEEL MEMBERS ARE TO RECEIVE CORROSSION PROTECTION IN
GLOSS LEVEL WHEN VIEWED FROM A DISTANCE OF 2M. ACCORDANCE WITH PROJECT SPECIFICATION.
No Description
STEEL WIRES FOR FIRE PROTECTION REQUIREMENTS ON STEEL MEMBERS REFER TO SAFETY, HEALTH AND ENVIRONMENT INFORMATION
WIRES ARE TO BE MANUFACTURED AS PER EN 1993-1-11. FIRE CONSULTANT'S REQUIREMENTS. Brief details on the identified hazard symbol referencing the unusual residual hazards / risks are listed above.

WIRES FOR FULLY LOCKED CABLES: WIRES OF THE Z-SHAPED WIRES SHALL NON-SHRINK GROUT TO HAVE A MINIMUM COMPRESSIVE STRENGTH OF 90
BE GALFAN (ZN95AL5) COATED. THE UTMOST EXPOSED Z-SHAPED WIRES ARE MPa AT 28 DAYS AND HAVING A WORKING TIME OF 2 HOURS.
TO BE GIVEN A GALFAN COAT WITH AT LEAST 300G/M.THE WIRES OF INNER
LAYERS CAN BE HOT DIP GALVANIZED OR GALFAN COATED. THE SHEAR POCKET OF EMBEDS SHALL BE FILLED TOTALLY WITH NON-
SHRINK GROUT AFTER THE PLACEMENT OF THE EMBED: AIR BUBBLES
WIRES FOR SPIRAL STRAND CABLES SHALL BE GALFAN (ZN95AL5) COATED. ARE NOT ALLOWED INSIDE THE POCKET TO ENSURE THE FULL BEARING T0 100% Schematic Design Issued For Tender JPW KS 07/06/2016
CONTACT TO TRANSFER THE FORCES TO THE CONCRETE. THE Rev Description Apvr Chk'd Date
Client
CONTRACTOR HAS TO PROVIDE THE NECESSARY HOLES IN THE BASE
PLATE WITH MINIMUM DIAMETER FOR GROUTING PROCESS.

Project Manager:

Design Consultant:

Project Title

THE FIFTH STADIUM PRECINCT


AL THUMAMA, DOHA, QATAR
Drawing Title

SCHEMATIC DESIGN - ISSUED FOR TENDER


FIFTH PRECINCT (STADIUM)
NOTES
GENERAL NOTES 1
Purpose of Issue Seal Date

SCHEMATIC DESIGN - ISSUED FOR TENDER 07/06/2016


Designed Drawn Checked

SBP TKem Schn


Model File Ref: Scale A1 (594x841) Revision No

C09-SBP-M-STA-C-ST-AL-AZ-0101
Drawing No
REV-T0
C09-AEB-D-STA-B-ST-AL-AZ-0001