Diesel Oxidation Catalyst Air Cleaning February 2016
Before performing this service routine, the cause of the DOC plugging should be found and corrected. Typical DOC plugging
causes are vehicle duty cycles that are: stop-and-go, have excessive idle time, have stationary PTO operation, or have a
hardware issue with the engine or vehicle. Perform the "ATD Checklist" to review these possible causes and correct them
before running this service routine.
The Diesel Oxidation Catalyst (DOC) air cleaning will remove soot that has built up on the face of the DOC. Air cleaning the
DOC will reduce the aftertreatment inlet pressure, allowing for a parked regeneration to safely run without damaging the
engine.
DOC air cleaning kit W470589239100 is compatible for use on EPA10 1-Box, GHG14 1-Box and 2016-2018 MDEG 1-Box
aftertreatment systems. You will also need an air gun with a six-inch tip and shop vacuum equipped with a dust bag to
capture soot removed from the aftertreatment. A shop vacuum with a 2 inch diameter hose will provide the best sealing
around the inlet reduction cone.
Table 1.
KIT CONTENT
Call Out Number Part Description Quantity
1 DOC block off plate 1
2 DOC cleaning cone 1
3 DOC V-band clamps 2
4 Inlet reduction cone 1
Check as follows:
1. Remove the 1-BOX aftertreatment from the vehicle. Refer to section "Removal of the 1-BOX from the Vehicle".
2. Remove the outboard heat shield (1) from the 1-BOX configuration by disengaging the folded flange on the top of
the outboard heat shield.
3. Remove the four mounting bolts (2) from the inboard heat shield (1). Slide the inboard heat shield down allowing better
access to the inboard (DPF) filter, V-band and flat band clamp.
NOTE: Record the orientation of the bands and clamps. These components need to be installed in the same
location.
4. Loosen the outboard V-band and flat band clamps on the outboard Diesel Particulate Filter (DPF).
5. Slide the outboard flat band clamp inward and the V-band clamp outward on the outboard DPF.
6. Remove the outboard DPF assembly (2) from the 1-BOX configuration and discard the flat band gasket (1).
7. Loosen the V-band and flat band clamps on the inboard DPF.
8. Slide the inboard flat band clamp inward and the V-band clamp outward on the inboard DPF.
9. Remove the inboard DPF (2) from the 1-BOX configuration and discard the flat band gasket (1).
10. Using DOC face cleaning kit W470589239100, slide the inlet reduction cone (3) over the aftertreatment inlet. See
graphic below.
11. Install the DOC block-off plate (2) over the inboard DOC and hand-tighten clamp.
12. Attach the DOC cleaning cone (1) to the outboard DOC and hand-tighten clamp.
13. Attach the shop vacuum hose to the aftertreatment reduction cone (3).
14. Turn on the shop vacuum; you should be able to feel suction if you place your hand momentarily over the DOC
cleaning cone opening.
NOTICE: Regulate air pressure to a maximum of 120 psi to prevent damage to the substrate.
15. Place the air gun nozzle inside the cleaning cone and keep the air gun tip 25 mm (1 in.) away from the DOC to prevent
damage to the brick.
16. Start blowing compressed air into the DOC cleaning cone. Move the air nozzle in a circular pattern, starting from the
outer edge and work your way inward to center of the DOC. Continue this motion for several minutes.
18. Continue blowing air into the DOC using a slow sweeping motion, making sure to cover 100% of the DOC surface.
Keep the air gun tip 25mm (1 in.) away from the DOC to prevent damage to the brick.
19. Move the block-off plate to the outboard DOC and install the cleaning cone onto the inboard DOC.
20. Place the air gun nozzle inside the cleaning cone, keep the air gun tip 25 mm (1 in.) away from the DOC to prevent
damage to the brick. Start blowing compressed air into the DOC cleaning cone. Move the air nozzle in a circular
pattern, starting from the outer edge and work your way inward to the center of the DOC. Continue this motion for
several minutes.
21. Remove the inboard DOC cleaning cone.
22. Continue blowing air into the inboard DOC using a slow sweeping motion making sure to cover 100% of the DOC
surface. Keep the air gun tip 25 mm (1 in.) away from the DOC to prevent damage to the brick.
23. Disconnect the vacuum and remove the inlet reduction cone and DOC block-off plate.
24. After each DOC has been air cleaned, reinstall both Diesel Particulate Filters (DPF) using new flat band clamps and V-
band gaskets.
25. Reinstall the aftertreatment.