You are on page 1of 174

INFORME DE MODELACIN DE

DISPERSIN ATMOSFRICA DE
CHIMENEAS
Octubre 2012 Marzo 2013

CORPORACIN ACEROS AREQUIPA S.A.


Sede N2 Pisco

Horno de Laminacin, Acera y Hierro


Esponja

JULIO 2013
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

NDICE
1. ASPECTOS GENERALES ................................................................................................................ 4
1.1. INTRODUCCIN ....................................................................................................................... 4
1.2. OBJETIVOS .............................................................................................................................. 4
1.3. UBICACIN ............................................................................................................................... 4
1.4. Metodologa ............................................................................................................................... 7
1.5. DESCRIPCION DEL PROCESO PRODUCTIVO ...................................................................... 7
1.5.1. Planta N2 CAASA - Sede Pisco ................................................................................. 7
1.5.2. Proceso de Reduccin Directa ...................................................................................... 8
1.5.3. Proceso de Fragmentacin de Metlicos ...................................................................... 9
1.5.4. Proceso de Acera......................................................................................................... 9
1.5.5. Proceso de Laminacin............................................................................................... 10
1.6. CARACTERISTICAS DE LAS FUENTES DE EMISION .......................................................... 11
1.7. CARACTERISTICAS DE LA ZONA DE ESTUDIO .................................................................. 12
1.7.1. Meteorologa ............................................................................................................... 12
1.8. CARACTERISTICAS TOPOGRAFICA .................................................................................... 21
1.8.1. Topografa................................................................................................................... 21
1.9. Resultados de Reporte de informe de Emisiones de chimeneas caasa (Octubre 2012
marzo 2013 ............................................................................................................................. 22
1.9.1. Resultados .................................................................................................................. 22
1.10. MODELO DE DISPERSIN SCREEN .................................................................................... 28
2. Procesamiento y RESULTADOS de datos PROVENIENTES DE LAS FUENTES DE HORNOS .. 30
2.1. HORNO DE ACERIA ............................................................................................................... 31
2.1.1. Datos de Ingreso del Horno Acera al modelo de dispersin ...................................... 31
2.1.2. Perfil de elevacin en el entorno del Horno de Acera ................................................ 32
2.1.3. Calculo de Altura Efectiva de chimenea (H)................................................................ 32
2.1.4. Anlisis de Pluma y Dispersin de Concentracin de Partculas PTS en Horno de
Acera.......................................................................................................................... 34
2.1.5. Resultados del Anlisis de Pluma y Dispersin de Concentracin de Partculas
PTS proveniente del Horno de Acera........................................................................ 35
2.1.6. Anlisis de Pluma y Dispersin de Concentracin de Partculas de Hierro (Fe) en
Horno de Acera .......................................................................................................... 37
2.1.7. Resultados del Anlisis de Pluma y Dispersin de Concentracin de Partculas de
Hierro proveniente del Horno de Acera ...................................................................... 38
2.1.8. Anlisis de Pluma y Dispersin de Concentracin de Monxido de Carbono (CO)
en Horno de Acera ..................................................................................................... 40
2.1.9. Resultados del Anlisis de Pluma y Dispersin de Concentracin de Monxido de
carbono proveniente del Horno de Acera .................................................................. 41
2.1.10. Anlisis de Pluma y Dispersin de Concentracin de xido de Nitrgeno (NOx)
en Horno de Acera ..................................................................................................... 43
2.1.11. Resultados del Anlisis de Pluma y Dispersin de Concentracin de Oxido de
Nitrgeno proveniente del Horno de Acera ................................................................ 44
2.1.12. Anlisis de Pluma y Dispersin de Concentracin de Dixido de Azufre (SO 2) en
Horno de Acera .......................................................................................................... 46

Pg. N 1
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

2.1.13. Resultados del Anlisis de Pluma y Dispersin de Concentracin de Dixido de


Azufre proveniente del Horno de Acera ..................................................................... 47
2.1.14. Resultados de concentraciones segn tipo de contaminantes proveniente del
Horno de Acera .......................................................................................................... 48
2.2. HORNO DE LAMINACIN ...................................................................................................... 49
2.2.1. Datos de Ingreso del Horno de Laminacin al modelo de dispersin ......................... 49
2.2.2. Perfil de elevacin en el entorno del Horno de laminacin ......................................... 50
2.2.3. Calculo de Altura Efectiva de chimenea (H)................................................................ 50
2.2.4. Anlisis de Pluma y Dispersin de Concentracin de Partculas PTS en Horno de
Laminacin.................................................................................................................. 52
2.2.5. Resultados del Anlisis de Pluma y Dispersin de Concentracin de Partculas
PTS proveniente de Horno de Laminacin ................................................................. 53
2.2.6. Anlisis de Pluma y Dispersin de Concentracin de Partculas de Hierro (Fe) en
Horno de Hierro Esponja ............................................................................................. 55
2.2.7. Resultados del Anlisis de Pluma y Dispersin de Concentracin de Partculas de
Hierro proveniente del Horno de Laminacin .............................................................. 56
2.2.8. Anlisis de Pluma y Dispersin de Concentracin de Monxido de Carbono (CO)
en Horno de Laminacin ............................................................................................. 58
2.2.9. Resultados del Anlisis de Pluma y Dispersin de Concentracin de Monxido de
carbono proveniente del Horno de Laminacin .......................................................... 59
2.2.10. Anlisis de Pluma y Dispersin de Concentracin de xido de Nitrgeno (NOx)
en Horno de Laminacin ............................................................................................. 61
2.2.11. Resultados del Anlisis de Pluma y Dispersin de Concentracin de Oxido de
Nitrgeno proveniente del Horno de Laminacin ........................................................ 62
2.2.12. Resultados de concentraciones segn tipo de contaminantes proveniente del
Horno de Laminacin .................................................................................................. 63
2.3. HORNO DE HIERRO ESPONJA ............................................................................................. 64
2.3.1. Datos de Ingreso del Horno Hierro Esponja al modelo de dispersin ........................ 64
2.3.2. Perfil de elevacin en el entorno del Horno de Hierro Esponja ................................... 65
2.3.3. Calculo de Altura Efectiva de chimenea (H)................................................................ 66
2.3.4. Anlisis de Pluma y Dispersin de Concentracin de Partculas PTS en Horno de
Hierro Esponja ............................................................................................................ 68
2.3.5. Resultados del Anlisis de Pluma y Dispersin de Concentracin de Partculas
PTS proveniente de Horno de Hierro Esponja ............................................................ 69
2.3.6. Anlisis de Pluma y Dispersin de Concentracin de Partculas de Hierro (Fe) en
Horno de Hierro Esponja............................................................................................. 71
2.3.7. Resultados del Anlisis de Pluma y Dispersin de Concentracin de Partculas de
Hierro proveniente del Horno de Acera ...................................................................... 72
2.3.8. Anlisis de Pluma y Dispersin de Concentracin de Monxido de Carbono (CO)
en Horno de Hierro Esponja ........................................................................................ 74
2.3.9. Resultados del Anlisis de Pluma y Dispersin de Concentracin de Monxido de
carbono proveniente del Horno de Hierro Esponja .................................................... 75
2.3.10. Anlisis de Pluma y Dispersin de Concentracin de xido de Nitrgeno (NOx)
en Horno de Hierro Esponja ........................................................................................ 77
2.3.11. Resultados del Anlisis de Pluma y Dispersin de Concentracin de Oxido de
Nitrgeno proveniente del Horno de Hierro Esponja ................................................... 78
2.3.12. Anlisis de Pluma y Dispersin de Concentracin de Dixido de Azufre (SO 2) en
Horno de Hierro Esponja ............................................................................................. 80

Pg. N 2
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

2.3.13. Resultados del Anlisis de Pluma y Dispersin de Concentracin de Dixido de


Azufre proveniente del Horno de Hierro Esponja ........................................................ 81
2.3.14. Resultados de concentraciones segn tipo de contaminantes proveniente del
Horno de Hierro Esponja ............................................................................................. 82
3. CONCLUSIONES............................................................................................................................ 83
4. ANEXOS ......................................................................................................................................... 84

Pg. N 3
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

1. ASPECTOS GENERALES
1.1. INTRODUCCIN

La Empresa Aceros Arequipa fue fundada el 13 de Mayo de 1964 en la Ciudad


de Arequipa, iniciando sus operaciones en noviembre de 1966, centrando sus
operaciones en la produccin y comercializacin de barras corrugadas, perfiles
y barras lisas de acero para la industria metal - mecnica, construccin y de
carpintera metlica.

En 1983 la empresa inaugura su segunda planta de laminacin en la ciudad de


Pisco, ubicada en el distrito de Paracas, provincia de Pisco, departamento de
Ica a la altura del Kilmetro 241 de la Panamericana Sur., e incursiona en la
fabricacin de Barras Corrugadas, Alambrn de Construccin y de Trefilera y
Barras de Molino,

Posteriormente en virtud, que se fusiona con otras empresas, adems de


ampliar sus operaciones, nuevas plantas y mejoras tecnolgicas, llevadas a
cabo entre los aos 1988, 1996, 1997 hasta la actualidad se dedica a la
fabricacin de acero en forma de Palanquillas, barras calibradas. Es as como
nace Corporacin Aceros Arequipa S.A. (CAASA), es una empresa siderrgica
que pertenece al sector industrial, dedicada a la produccin de productos de
acero corrugado, alambre, perfiles y otros productos para el sector de la
construccin.

El presente informe de modelacin de dispersin atmosfrica tiene la finalidad


de simular y predecir el efecto que producira el comportamiento de las
emisiones atmosfricas de concentraciones de partculas (PTS, Fe) y gases
(CO, NOx y SO2) de los hornos de Laminacin, Acera y Hierro Esponja. Esta
estimacin se realiz utilizando un software informtico denominado modelo de
dispersin de la calidad del aire SCREEN 3 (en base a la aplicacin de un
modelo matemtico de dispersin - modelo gaussiano), a partir de las
emisiones producidas por el proceso productivo, el cual mediante la resolucin
de ecuaciones de transporte, permitir tener un aproximacin sobre los niveles
de inmisin generados por las emisiones de las fuentes de los hornos.

1.2. OBJETIVOS

Realizar el modelamiento de dispersin atmosfrica para partculas (PTS,


Fe) y Gases (SO2, NOx, CO).

Anlisis de la informacin meteorolgica y topogrfica de la zona de


estudio.
1.3. UBICACIN

El emplazamiento de las instalaciones de la Planta de Pisco, se ubica a la


altura del Km.241 de la carretera Panamericana del Sur, a 6,5 km al Este de la

Pg. N 4
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

baha de Paracas y a 8.9 km. de la ciudad de Pisco distrito de Paracas,


provincia de Pisco, Departamento de Ica.

Las coordenadas del rea industrial son:

Norte : 8 475 600

Este : 378 000

En la siguiente imagen satelital se muestra la localizacin general de la Planta


industrial (Sede N 2).

FIGURA N 1 Vista Panormica Google Earth de la Planta de Aceros


Arequipa Sede N2 - Pisco

PROPIEDAD DE
FUNSUR

ACEROS
AREQUIPA
PLANTA N 2

La planta se localiza en la zona costera, que se caracteriza por la presencia de


amplias pampas, interrumpidas ocasionalmente por lomadas de relieve suave o
por quebradas; gran parte de las cuales se encuentran cubiertas por depsitos
elicos (dunas), donde se realiza erosin elica, adems se observa la
presencia de actividades industriales en la cercanas de la Planta (FUNSUR) y
adyacente a la planta se encuentra la Carretera Panamericana Sur, los cuales
son factores que pueden estar influenciando de una forma no regular ni
homognea como focos de emisin.

Pg. N 5
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

MAPA N 1 Plano de Ubicacin Planta de Aceros Arequipa Sede N2 - Pisco

Pg. N 6
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

1.4. METODOLOGA

Para efectos de conocer el aporte de emisiones de los procesos sobre el


entorno, se ha realizado una modelacin de las emisiones utilizando un modelo
del tipo Gaussiano (SCREEN3) bajo la interfaz Screen View de la empresa
Lakes Environmental, tanto de Material Particulado (PTS, Fe) y Gases de (CO,
NOX y SO2).
El modelo SCREEN examina un amplio rango de condiciones meteorolgicas,
incluyendo todas las clases de estabilidad y velocidades del viento para
encontrar impactos mximos, mientras que en los clculos manuales, con el fin
de mantenerlos manejables, slo se examina un subconjunto de las
condiciones meteorolgicas (clases de estabilidad A, B, C, E o F) basadas en
las estabilidades atmosfricas establecidas por Pasquil y Gifford.

Los datos que se obtienen del modelo corresponden a las concentraciones


horarias (1 hora). De acuerdo a lo establecido por EPA en el documento
Screening Procedures for Estimating the Air Quality Impact of Stationary
Sources.

Para la interpretacin sobre las distribuciones de velocidades del viento y la


frecuencia de variacin de las direcciones del viento, se elabor la Rosa de
Vientos empleando el software WRPLOT View 6.5.1. Lakes Enviromental

1.5. DESCRIPCION DEL PROCESO PRODUCTIVO

A continuacin se describen las etapas del proceso productivo:

1.5.1. Planta N2 CAASA - Sede Pisco

Esta planta, con una capacidad de produccin de 550,000 toneladas de acero


lquido y 450,000 toneladas mtricas anuales de productos terminados, se
encuentra ubicada en el desierto de Paracas - Ica, en el Km. 241 de la
Panamericana Sur. Est conformada por la Planta de Hierro Esponja, la Planta
de Acera, la Planta de Laminacin, y las instalaciones para el servicio de corte
y doblado de barras de acero corrugado a medida.

Produce barras corrugadas y lisas, perfiles, barras cuadradas y redondas,


barras helicoidales, alambrn de construccin y de trefilera.

En Aceros Arequipa, se ha invertido en mejoras que vienen haciendo que la


produccin del acero sea cada vez ms amigable con el medio ambiente. Se
ha invertido en la construccin de un nuevo sistema de evacuacin y
tratamiento de humos de la planta de acera.

Pg. N 7
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

Ahora con los filtros de mangas, succin y sistemas auxiliares de agua y aire
comprimido de la Planta de tratamiento se emite una cantidad mucho menor a
la exigida por los estndares internacionales.

Por otro lado, luego de la fusin, la escoria conformada por residuos metlicos
y no metlicos, se evacua del horno elctrico y se recoge para su reutilizacin;
los residuos metlicos vuelven a la zona de metlicos, los segundos se envan
a las municipalidades cercanas para el asfaltado de pistas.

En todas las etapas del proceso de produccin, se generan diferentes tipos de


residuos: finos de mineral de hierro, finos de hierro esponja y cascarilla de
acero. Actualmente, estos residuos pasan por un proceso de aglomeracin y
vuelven a los hornos. De esta manera se reduce significativamente el
desperdicio y la acumulacin de pasivos ambientales.

El uso del gas natural como fuente de energa en las diferentes plantas de
Aceros Arequipa tambin est ayudando a reducir emisiones de gases
contaminantes al ambiente pero adems, estn contribuyendo al ahorro de
energa y consecuentemente a una mayor productividad de la empresa de cara
al futuro.

1.5.2. Proceso de Reduccin Directa

Un componente importante en la produccin del acero es el hierro esponja. Se


le denomina as porque al mineral de hierro se le ha extrado el oxgeno,
convirtindose en un material sumamente liviano. La materia prima del hierro
esponja es el fierro o mineral de hierro. Esta llega en forma de pellets y se
almacena en silos junto con el carbn y la caliza.

Aqu se reduce el mineral de hierro, liberndolo del oxgeno gracias a la accin


del carbn, para as elevar el porcentaje de contenido de hierro metlico y
utilizarlo en el horno elctrico, como carga metlica en la fabricacin del acero,
con la ventaja de obtener un producto con menor cantidad de residuales y
mejores propiedades.

Para tener un mejor control en los procesos de Acera y Laminacin, as como


mejorar la calidad de sus productos, Aceros Arequipa puso en funcionamiento
en 1996 esta planta, que opera con dos hornos tubulares rotatorios inclinados
tipo "kiln", el cual produce 12 toneladas de hierro esponja por hora lo que hace
un promedio de 45,000 t/a (toneladas anuales) cada uno; siendo la produccin
total de 90,000 t/a.

El mineral del hierro, junto con el carbn y la caliza ingresan a los hornos
rotatorios a una velocidad controlada por la misma rotacin. El interior de los
hornos est recubierto de material refractario. Por efecto de la combustin, se
produce dixido de carbono, el cual favorece la reduccin del mineral de hierro.
Para controlar la temperatura, se dispone de ventiladores a lo largo del horno
los que brindan el aire necesario para la combustin del carbn. El hierro

Pg. N 8
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

esponja obtenido, pasa luego al enfriador rotatorio donde se le suministra agua


para su refrigeracin.

Al final, la carga metlica fragmentada se apila en la baha de carga en espera


de su utilizacin.

1.5.3. Proceso de Fragmentacin de Metlicos

Otro componente en la produccin del acero es la carga metlica. En la zona


de metlicos, se acopia el acero a reciclar, segn su carga residual y su
densidad, determinada por una junta calificadora.

La compra de acero en desuso, viene generando un importante mercado de


trabajo en nuestro pas que contribuye adems al cuidado del medio ambiente.

La carga metlica, pasa por un proceso de corte y triturado en la planta


fragmentadora de Aceros Arequipa. En el interior de la fragmentadora,
poderosos martillos reducen la carga a un tamao ptimo. Luego, a travs de
una faja transportadora, la carga fragmentada pasa por una serie de rodillos
magnticos que seleccionan todo lo metlico. Los materiales que no lo son, se
desvan por otro conducto para su almacenamiento o su cuidadosa eliminacin.

En la zona de carga, al hierro esponja se le aade la carga metlica


fragmentada. Esta mezcla se lleva a la Planta de Acera para iniciar la
produccin del acero.

1.5.4. Proceso de Acera

En la Planta de Acera se cuenta con un patio de Metlicos y Hierro Esponja.


La lnea de produccin cuenta con un Horno Elctrico de Fusin AC de 80 t y
un Horno de Afino (Horno Cuchara).

El Horno de Fusin tiene un transformador de 45 MVA, adems 4 lanzas


supersnicas de inyeccin de oxgeno, instaladas en su estructura metlica.
Los paneles y la bveda son refrigerados con agua.

Cuando la mezcla de hierro esponja y la carga metlica ingresa al horno, la


puerta principal es cubierta con una masa selladora. Esto evita el ingreso
excesivo de aire y permite mantener mejor el calor. En el interior del horno
elctrico, la principal energa usada para fundir la carga es la energa elctrica
producida por tres electrodos que generan temperaturas por encima de los
3,000 C a 5,000 C. Tambin se produce energa qumica producto de la
oxidacin. El hierro esponja y la carga metlica se funden a 1600 C,
obtenindose as el acero lquido.

Luego de 40 minutos de combustin, el acero lquido pasa al horno cuchara en


donde otros tres electrodos realizan el afino, es decir se ajusta la composicin
qumica del acero, logrando as la calidad necesaria para el producto. Luego, a

Pg. N 9
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

travs de la buza u orificio ubicado en la base de la cuchara, el acero pasa a la


colada continua.

Se inicia vertiendo el acero lquido de la cuchara al tundish o distribuidor, que


reduce la turbulencia del flujo y lleva el acero lquido por 4 lneas de colada o
moldes oscilatorios en donde se le da una refrigeracin primaria para
solidificarla superficialmente. Luego, mediante sprays y toberas se realiza la
refrigeracin secundaria. Esta barra solidificada es cortada obtenindose as la
palanquilla, el producto final de la acera y la materia prima para la laminacin.
Todo este proceso es muy importante porque de l depende la calidad de la
palanquilla y del producto final.

La capacidad de produccin anual es de 550,000 t/a de palanquilla de


diferentes secciones, (100x100mm, 130x130mm y 150x150mm), que se
destina a la fabricacin de barras corrugadas, perfiles, alambrones y aceros
especiales.

Dentro del proceso continuo de mejora tecnolgica, la Planta de Acera ha


logrado avances significativos que incluyen el desarrollo de tecnologa propia
patentada, permitiendo ubicar al Horno Elctrico de Aceros Arequipa entre los
ms rpidos y potentes del mundo, y haciendo que en los ltimos aos la
produccin de palanquilla se incremente sustancialmente.

La modernizacin del horno, el proceso a puerta cerrada y el uso de metlicos


sin residuos, han permitido a Aceros Arequipa incrementar la productividad de
la planta de acera y asegurar la calidad de los diferentes aceros producidos.

1.5.5. Proceso de Laminacin

La ltima parte del proceso de produccin del acero es la laminacin en


caliente, donde las palanquillas se transforman en los diferentes productos de
acero largo que el mercado nacional e internacional exige.
Tiene dos lneas de fabricacin; una para la produccin de barras de
construccin, perfiles, ngulos, tees, barras cuadradas, redondas lisas, barras
helicoidales; y otra para la fabricacin de alambrones para trefilera, electrodos
y construccin.

La laminacin empieza con el calentamiento de la palanquilla en el horno re-


calentador a una temperatura de trabajo que vara entre los 1,100C y los
1200C. De ah pasa al tren de laminacin, donde se inicia el estiramiento de la
palanquilla a travs de cajas de desbaste y rodillos formando as las barras y
perfiles, segn el tipo de rodillo acabador que se haya colocado, y de acuerdo
al largo que se desea obtener.

La primera etapa del tren de laminacin es el tren de desbaste que consta de


ocho cajas; seguidas por el tren intermedio y continuo que tiene diez casetas
convertibles de ltima generacin. En la Lnea de Barras, despus de la Caseta

Pg. N 10
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

Acabadora, el producto terminado es cortado con una cizalla volante a una


longitud de 54 m 60 m, y es enfriado al medio ambiente en la Placa de
Enfriamiento.

Si se desea obtener alambrn, el acero laminado se transfiere caliente al nuevo


tren de alambrn, donde se produce en diferentes dimetros y luego pasan al
bobinador que forma los rollos.

Para la fabricacin de alambrones se tiene un Block BGV de diez pasadas de


alta velocidad; llegando hasta los 100m/seg.; el enfriamiento del alambrn es
controlado con el fin de obtener las caractersticas mecnicas y metalrgicas.
Los rollos de alambrn son embalados e identificados en bobinas de hasta dos
toneladas de peso.

Finalizado el proceso de laminacin. Todos los productos de Aceros Arequipa


se entregan al mercado, debidamente empaquetados y etiquetados, con un
cdigo de barras que permite conocer sus caractersticas, evitando as errores
en la entrega y garantizando un total control de la calidad del producto

.
1.6. CARACTERISTICAS DE LAS FUENTES DE EMISION

El presente estudio de modelamiento de dispersin atmosfrica, se ha basado


en informacin especfica y cuantificable obtenida de los informes de monitoreo
ambiental realizados a CAASA, desde el ao 2012 (Octubre, Noviembre,
Diciembre,), hasta el ao 2013 (Enero, febrero, Marzo), de las tres principales
fuentes de emisiones de la planta de CAASA como son:

Chimenea del Horno de Acera


Chimenea del Horno de Laminacin
Chimenea del Horno de Hierro Esponja

Pg. N 11
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

Cuadro N 1 Ubicacin y caractersticas de las Fuentes de emisiones de


Chimeneas de la Planta de CAASA Sede N2

Nombre de la Chimenea Ubicacin coordenadas Altura de Dimetro de


UTM chimenea Chimenea
(m) (m)
Norte Este

Horno de Acera 8 476 032 373 740 16.5 4.20

(Horno Elctrico)

Horno de Laminacin 8 475 960 373 972 25 1.5

(Horno Danieli)

Horno de Hierro Esponja (Horno 8 475 936 373 710 29 1.6


N 01 y 02 )
Elaboracin Propia

1.7. CARACTERISTICAS DE LA ZONA DE ESTUDIO

1.7.1. Meteorologa

Para la informacin meteorolgica empleada en el presente modelamiento de


dispersin se ha utilizado:

1.- Informacin de datos histricos.

2.- Informacin de datos de registros meteorolgicos, que concuerden en


periodos de monitoreo de emisiones atmosfricas realizados a CAASA, desde
el ao 2012 (Octubre, Noviembre, Diciembre,), hasta el ao 2013 (Enero,
febrero, Marzo).

1.- Informacin de datos histricos.

Se ha recopilado informacin de datos histricos de velocidad y direccin de


viento procesados desde 15/03/2010 al 13/03/2012 como informacin base de
la estacin meteorolgica que se ubica en el techo de las oficinas del
Departamento de Medio Ambiente (373727.00 m E, 8475971.00 m N).

Los resultados indican que la velocidad promedio en la zona, se encuentra


entre los 2,15 m/s y la direccin predominante de los vientos, ms frecuente se
origina en el Oeste (W) y Oeste Suroeste (WSW) ver en el siguiente grfico.

Pg. N 12
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

Grfico N 1 Rosa de Vientos de datos histricos de Planta CAASA Sede Pisco (15/03/2010 al 13/03/2012)
WIND ROSE PLOT: DISPLAY: COMMENTS:

ESTACION METEREOLOGICA ACEROS AREQUIPA- SEDE N2 Wind Speed


Direction (blowing from) ROSA DE VIENTO
ROSA DE VIENTO CORPORACION ACEROS
AREQUIPA S.A.

NORTH

40% DATA PERIOD:

Start Date: 15/03/2010 - 18:00


32% End Date: 13/03/2012 - 16:00

TOTAL COUNT: CALM WINDS:


24%
33250 hrs. 0.00%

16% AVG. WIND SPEED:

2.15 m/s
8%
WEST EAST

MODELER:
WIND SPEED RUBEN MARCOS
(m/s)
HUATUCO
>= 15.0 DATE:

12.0 - 15.0
19/03/2012
10.0 - 12.0
8.0 - 10.0
6.0 - 8.0
4.0 - 6.0
3.0 - 4.0
2.0 - 3.0
0.0 - 2.0
SOUTH Calms: 0.00%
PROJECT NO.:

1
WRPLOT View - Lakes Environmental Software

Pg. N 13
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

2.- Informacin de datos de registros meteorolgicos, que concuerden en


periodos de monitoreo de emisiones atmosfricas 2012 y 2013.

En base a los requerimientos de informacin para el presente modelamiento, la


informacin sobre velocidad y direccin del viento en la zona de estudio se
caracteriz los datos meteorolgicos registrados en la estacin porttil (ubicado
a 20m Noreste de la entrada a la planta, coordenadas UTM: 373954m E,
8475702m N) cada hora para un periodo de 3 das en los meses de octubre,
noviembre y diciembre del ao 2012, adems de los meses de enero, febrero y
marzo del ao 2013.

A continuacin se presentan las rosas de viento cada uno de los meses de los
aos 2012 y 2013

Cuadro N 2 Resumen de Resultados de datos meteorolgicos de


Temperatura, Humedad, Velocidad y Direccin de Viento (Octubre 2012
hasta Marzo del 2013)

tem Humedad Velocidad Direccin del


Fecha de Temperatura
Relativa (% del Viento Viento (viene
Monitoreo (C)
HR) (m/s) de)

Octubre 2012 Mximo 26.30 88.00 3.60

Mnimo 13.80 47.00 0.00 SW


03 al 06/10/2012
Promedio 18.84 71.31 0.85

ROSA DE VIENTOS

Pg. N 14
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

Cuadro N 3 Resumen de Resultados de datos meteorolgicos de


Temperatura, Humedad, Velocidad y Direccin de Viento (Noviembre del
2012)

tem Humedad Velocidad Direccin del


Fecha de Temperatura
Relativa (% del Viento Viento (viene de)
Monitoreo (C)
HR) (m/s)

Noviembre 2012 Mximo 26.80 81.00 3.10

Mnimo 16.60 50.00 0.00 SSW


08 al 10/11/2012
Promedio 21.19 68.35 1.24

WIND ROSE PLOT: ROSA DE VIENTOS DISPLAY: COMMENTS:

ESTACION METEREOLOGICA CORPORACION ACEROS AREQUIPA S.A. Wind Speed


Direction (blowing from)
OCTUBRE 2012

NORTH

45% DATA PERIOD:

Start Date: 08/11/2012 - 00:00


36% End Date: 10/11/2012 - 06:00

27% TOTAL COUNT: CALM WINDS:

48 hrs. 0.00%

18% AVG. WIND SPEED:

1.24 m/s
9%
COMPANY NAME:

WEST EAST

MODELER:
WIND SPEED ING.RUBEN MARCOS
(m/s) HUATUCO
>= 15.0 DATE:

10.0 - 15.0
31/07/2013
8.0 - 10.0
6.0 - 8.0
4.0 - 6.0
3.0 - 4.0
2.0 - 3.0
1.0 - 2.0
Resultant Vector 0.0 - 1.0 PROJECT NO.:
224 deg - 88% SOUTH
Calms: 0.00%
2
WRPLOT View - Lakes Environmental Software

Pg. N 15
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

Cuadro N 4 Resumen de Resultados de datos meteorolgicos de


Temperatura, Humedad, Velocidad y Direccin de Viento (Diciembre del
2012)

tem Humedad Velocidad Direccin del


Fecha de Temperatura
Relativa (% del Viento Viento (viene de)
Monitoreo (C)
HR) (m/s)

Diciembre 2012 Mximo 28.40 86.00 3.20

Mnimo 19.40 51.00 0.00 SW


12 al 15/12/2012
Promedio 22.54 72.47 1.30

WIND ROSE PLOT: DISPLAY: COMMENTS:

ESTACION METEREOLOGICA CORPORACION ACEROS AREQUIPA S.A. ROSA DE VIENTOS Wind Speed
Direction (blowing from)
NOVIEMBRE 2012

NORTH

40% DATA PERIOD:

Start Date: 12/12/2012 - 00:00


32% End Date: 15/12/2012 - 13:00

24% TOTAL COUNT: CALM WINDS:

72 hrs. 0.00%

16% AVG. WIND SPEED:

1.30 m/s
8%
COMPANY NAME:

WEST EAST

MODELER:
WIND SPEED ING.RUBEN MARCOS
(m/s) HUATUCO
>= 15.0 DATE:

10.0 - 15.0
31/07/2013
8.0 - 10.0
6.0 - 8.0
4.0 - 6.0
3.0 - 4.0
2.0 - 3.0
1.0 - 2.0
Resultant Vector 0.0 - 1.0 PROJECT NO.:
215 deg - 86% SOUTH
Calms: 0.00%
2
WRPLOT View - Lakes Environmental Software

Pg. N 16
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

Cuadro N 5 Resumen de Resultados de datos meteorolgicos de


Temperatura, Humedad, Velocidad y Direccin de Viento (Enero del 2013)

tem Humedad Velocidad Direccin del


Fecha de Temperatura
Relativa (% del Viento Viento (viene de)
Monitoreo (C)
HR) (m/s)

Enero 2013 Mximo 29.10 91.00 2.70

Mnimo 19.70 52.00 0.00 NW


09 al 11/01/2013
Promedio 23.22 75.25 1.04

WIND ROSE PLOT:

ESTACION METEREOLOGICA CORPORACION ACEROS AREQUIPA S.A.


ROSA DE VIENTOS DISPLAY:

Wind Speed
COMMENTS:

Direction (blowing from)


DICIEMBRE 2012

NORTH

35% DATA PERIOD:

Start Date: 09/01/2013 - 00:00


28% End Date: 11/01/2013 - 15:00

21% TOTAL COUNT: CALM WINDS:

47 hrs. 0.00%

14% AVG. WIND SPEED:

1.06 m/s
7%
COMPANY NAME:

WEST EAST

MODELER:
WIND SPEED ING.RUBEN MARCOS
(m/s) HUATUCO
>= 15.0 DATE:

10.0 - 15.0
31/07/2013
8.0 - 10.0
6.0 - 8.0
4.0 - 6.0
3.0 - 4.0
2.0 - 3.0
1.0 - 2.0
Resultant Vector 0.0 - 1.0 PROJECT NO.:
345 deg - 65% SOUTH
Calms: 0.00%
2
WRPLOT View - Lakes Environmental Software

Pg. N 17
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

Cuadro N 6 Resumen de Resultados de datos meteorolgicos de


Temperatura, Humedad, Velocidad y Direccin de Viento (Febrero del 2013)

tem Humedad Velocidad Direccin del


Fecha de Temperatura
Relativa (% del Viento Viento (viene de)
Monitoreo (C)
HR) (m/s)

Febrero 2013 Mximo 30.60 90.00 3.60

Mnimo 20.20 47.00 0.00 NW


05 al 08/02/2013
Promedio 24.90 71.25 0.84

WIND ROSE PLOT:

ESTACION METEREOLOGICA CORPORACION ACEROS AREQUIPA S.A.


ROSA DE VIENTOS DISPLAY:

Wind Speed
COMMENTS:

Direction (blowing from)


ENERO 2013

NORTH

35% DATA PERIOD:

Start Date: 05/02/2013 - 00:00


28% End Date: 08/02/2013 - 14:00

21% TOTAL COUNT: CALM WINDS:

71 hrs. 0.00%

14% AVG. WIND SPEED:

0.86 m/s
7%
COMPANY NAME:

WEST EAST

MODELER:
WIND SPEED ING.RUBEN MARCOS
(m/s) HUATUCO
>= 15.0 DATE:

10.0 - 15.0
31/07/2013
8.0 - 10.0
6.0 - 8.0
4.0 - 6.0
3.0 - 4.0
2.0 - 3.0
1.0 - 2.0
Resultant Vector 0.0 - 1.0 PROJECT NO.:
342 deg - 40% SOUTH
Calms: 0.00%
2
WRPLOT View - Lakes Environmental Software

Pg. N 18
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

Cuadro N 7 Resumen de Resultados de datos meteorolgicos de


Temperatura, Humedad, Velocidad y Direccin de Viento (Marzo del 2013)

tem Humedad Velocidad Direccin del


Fecha de Temperatura
Relativa (% del Viento Viento (viene de)
Monitoreo (C)
HR) (m/s)

Marzo 2013 Mximo 31.90 85.00 3.10

Mnimo 20.80 47.00 0.00 NW


05 al 08/03/2013
Promedio 25.40 69.96 0.71

WIND ROSE PLOT: ROSA DE VIENTOS DISPLAY: COMMENTS:

ESTACION METEREOLOGICA CORPORACION ACEROS AREQUIPA S.A. Wind Speed


Direction (blowing from)
FEBRERO 2013

NORTH

35% DATA PERIOD:

Start Date: 05/03/2013 - 00:00


28% End Date: 08/03/2013 - 13:00

21% TOTAL COUNT: CALM WINDS:

72 hrs. 0.00%

14% AVG. WIND SPEED:

0.71 m/s
7%
COMPANY NAME:

WEST EAST

MODELER:
WIND SPEED ING.RUBEN MARCOS
(m/s) HUATUCO
>= 15.0 DATE:

10.0 - 15.0
31/07/2013
8.0 - 10.0
6.0 - 8.0
4.0 - 6.0
3.0 - 4.0
2.0 - 3.0
1.0 - 2.0
Resultant Vector 0.0 - 1.0 PROJECT NO.:
305 deg - 78% SOUTH
Calms: 0.00%
2
WRPLOT View - Lakes Environmental Software

Pg. N 19
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

Grfico N 2 Rosa de Viento registrados en la estacin meteorolgica


CAASA Sede Pisco (Octubre 2012 Marzo 2013)

Pg. N 20
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

1.8. CARACTERISTICAS TOPOGRAFICA

1.8.1. Topografa

A continuacin se muestra el plan topogrfico con sus respectivas cotas de la


zona donde se emplaza la planta industrial.

FIGURA N 2 Plano Topogrfico del entorno de la Planta de Aceros


Arequipa Sede N2 - Pisco

Pg. N 21
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

1.9. RESULTADOS DE REPORTE DE INFORME DE EMISIONES DE CHIMENEAS CAASA (OCTUBRE 2012 MARZO 2013)

1.9.1. Resultados

Cuadro N 8 Resultados de Reporte de informe de Monitoreo de Emisiones Atmosfricas - Octubre 2012


EMPRESA ACEROS AREQUIPA S.A. SEDE N2 PISCO
HORNO DE ACERIA HORNO DE LAMINACIN HORNO DE HIERRO ESPONJA

FECHA DE FECHA DE FECHA DE


OCTUBRE 2012 03/10/2012 05/10/2012 04/10/2012
MONIT.: MONIT.: MONIT.:
TASA DE TASA DE TASA DE
Unid. Unid. Unid.
EMISION EMISION EMISION
PROMEDIO PROMEDIO PROMEDIO
Unid. Unid. Unid.
ARITMTICO (1) ARITMTICO ARITMTICO

FLUJO VOLUMTRICO (A) Nm3/h 632790.34 Nm3/h 42801.52 Nm3/h 63689.550

PARTCULAS (B) mg/Nm3 0.57 0.100 g/s mg/Nm3 27.58 0.328 g/s mg/Nm3 388.95 6.881 g/s
HIERRO mg/Nm3 0.23 0.040 g/s mg/Nm3 0.81 0.010 g/s mg/Nm3 9.76 0.173 g/s
VELOCIDAD m/s 18.15 m/s 17.04 m/s 14.85
FLUJO MASICO kg/h 814717.56 kg/h 56100.57 kg/h 85753.43
MONOXIDO DE CARBONO mg/Nm3 238.77 41.970 g/s mg/Nm3 0.96 0.011 g/s mg/Nm3 67.01 1.186 g/s
3 3
XIDOS DE NITRGENO mg/Nm 17.80 3.129 g/s mg/Nm 149.53 1.778 g/s mg/Nm3 52.22 0.924 g/s
DIXIDO DE AZUFRE mg/Nm3 1.90 0.334 g/s mg/Nm3 0.00 0.000 g/s mg/Nm3 590.61 10.449 g/s

PARMETROS COMPLEMENTARIOS
OXIGENO % O2 20.22 % O2 8.00 % O2 13.66
TEMPERATURA DE GASES C 101.80 374.800 K C 378.30 651.300 K C 166.10 439.100 K

TEMPERATURA AMBIENTE C 25.33 298.330 K C 20.60 293.600 K C 20.60 293.600 K


DIXIDO DE CARBONO % 0.28 % 7.25 % 6.95
EXCESO DE AIRE % 1454.33 55.03 183.53
EFICIENCIA DE COMBUSTIN % 46.90 % 73.77 % 83.63

ALTURA DE CHIMENEA m 16.50 m 25.00 m 29.00


DIMETRO EQUIVALENTE m 4.20 m 1.50 m 1.60

CALCULO TASA DE EMISION (TE)


(x)

TE(g/s)=((A(1)*B(1)*0.001)/3600)

Environmental Hygiene & Safety SRL Pg. N 22


Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

Cuadro N 9 Resultados de Reporte de informe de Monitoreo de Emisiones Atmosfricas - Noviembre 2012


EMPRESA ACEROS AREQUIPA S.A. SEDE N2 PISCO
HORNO DE ACERIA HORNO DE LAMINACIN HORNO DE HIERRO ESPONJA

FECHA DE FECHA DE FECHA DE


NOVIEMBRE 2012 07/11/2012 9/11/2012 8/11/2012
MONIT.: TASA DE MONIT.: TASA DE MONIT.: TASA DE
Unid. Unid. Unid.
EMISION EMISION EMISION
PROMEDIO PROMEDIO PROMEDIO
Unid. Unid. Unid.
ARITMTICO ARITMTICO ARITMTICO

FLUJO VOLUMTRICO (A) Nm3/h 647110.83 Nm3/h 23523.03 Nm3/h 43757.91


PARTCULAS (B) mg/Nm3 1.44 0.259 g/s mg/Nm3 5.32 0.035 g/s mg/Nm3 15.93 0.194 g/s
HIERRO mg/Nm3 0.31 0.056 g/s mg/Nm3 1.30 0.008 g/s mg/Nm3 1.71 0.021 g/s
VELOCIDAD m/s 18.31 m/s 9.97 m/s 11.07
TIEMPO DE EMISIN h/d 24.00 h/d 24.00 h/d 24.00
FLUJO MASICO kg/h 833155.20 kg/h 30831.97 kg/h 58916.90

MONOXIDO DE CARBONO mg/Nm3 453.37 81.495 g/s mg/Nm3 26.97 0.176 g/s mg/Nm3 61.14 0.743 g/s

XIDOS DE NITRGENO mg/Nm3 6.85 1.231 g/s mg/Nm3 197.39 1.290 g/s mg/Nm3 79.78 0.970 g/s
3 3 3
DIXIDO DE AZUFRE mg/Nm 0.00 0.000 g/s mg/Nm 0.00 0.000 g/s mg/Nm 506.43 6.156 g/s

PARMETROS
COMPLEMENTARIOS
OXIGENO % O2 19.34 % O2 11.51 % O2 11.39

TEMPERATURA DE GASES C 102.46 375.460 K C 398.50 671.500 K C 193.07 466.070 K


TEMPERATURA AMBIENTE C 26.17 299.170 K C 25.40 298.400 K C 22.70 295.700 K
DIXIDO DE CARBONO % 0.91 % 5.28 % 9.10
EXCESO DE AIRE % 1049.83 109.00 116.87
EFICIENCIA DE COMBUSTIN % 61.80 % 66.67 % 84.93

ALTURA DE CHIMENEA m 16.50 m 25.00 m 29.00


DIMETRO EQUIVALENTE m 4.20 m 1.50 m 1.60

Environmental Hygiene & Safety SRL Pg. N 23


Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

Cuadro N 10 Resultados de Reporte de informe de Monitoreo de Emisiones Atmosfricas - Diciembre 2012


EMPRESA ACEROS AREQUIPA S.A. SEDE N2 PISCO
HORNO DE ACERIA HORNO DE LAMINACIN HORNO DE HIERRO ESPONJA

FECHA DE FECHA DE FECHA DE


DICIEMBRE 2012 13/12/2012 12/12/2012 14/12/2012
MONIT.: TASA DE MONIT.: TASA DE MONIT.: TASA DE
Unid. Unid. Unid.
PROMEDIO EMISION PROMEDIO EMISION PROMEDIO EMISION
Unid. Unid. Unid.
ARITMTICO ARITMTICO ARITMTICO

FLUJO VOLUMTRICO (A) Nm3/h 653854.40 Nm3/h 32588.55 Nm3/h 86264.07


3 3 3
PARTCULAS (B) mg/Nm 1.08 0.196 g/s mg/Nm 4.11 0.037 g/s mg/Nm 12.77 0.306 g/s
HIERRO mg/Nm3 0.02 0.004 g/s mg/Nm3 0.70 0.006 g/s mg/Nm3 0.22 0.005 g/s
VELOCIDAD m/s 18.12 m/s 11.01 m/s 16.37
TIEMPO DE EMISIN h/d 24.00 h/d 24.00 h/d 24.00
FLUJO MASICO kg/h 841837.54 kg/h 42714.27 kg/h 116656.76
3 3 3
MONOXIDO DE CARBONO mg/Nm 201.27 36.556 g/s mg/Nm 0.42 0.004 g/s mg/Nm 78.94 1.892 g/s
3 3 3
XIDOS DE NITRGENO mg/Nm 2.74 0.498 g/s mg/Nm 146.99 1.331 g/s mg/Nm 62.29 1.493 g/s
3 3 3
DIXIDO DE AZUFRE mg/Nm 0.00 0.000 g/s mg/Nm 0.00 0.000 g/s mg/Nm 501.55 12.018 g/s

PARMETROS
COMPLEMENTARIOS
OXIGENO % O2 19.79 % O2 10.80 % O2 13.19
TEMPERATURA DE GASES C 99.37 372.370 K C 298.10 571.100 K C 169.73 442.730 K
TEMPERATURA AMBIENTE C 30.50 303.500 K C 26.20 299.200 K C 28.00 301.000 K
DIXIDO DE CARBONO % 0.66 % 5.69 % 7.40
EXCESO DE AIRE % 1458.67 97.03 166.37
EFICIENCIA DE COMBUSTIN % 55.73 % 74.20 % 84.73

ALTURA DE CHIMENEA m 16.50 m 25.00 m 29.00


DIMETRO EQUIVALENTE m 4.20 m 1.50 m 1.60

Environmental Hygiene & Safety SRL Pg. N 24


Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

Cuadro N 11 Resultados de Reporte de informe de Monitoreo de Emisiones Atmosfricas - Enero 2013


EMPRESA ACEROS AREQUIPA S.A. SEDE N2 PISCO
HORNO DE ACERIA HORNO DE LAMINACIN HORNO DE HIERRO ESPONJA
FECHA FECHA FECHA
ENERO 2013 DE 11/01/2013 DE 10/01/2013 DE 09/01/2013
MONIT.: TASA DE MONIT.: TASA DE MONIT.: TASA DE
Unid. Unid. Unid.
EMISION EMISION EMISION
PROMEDIO PROMEDIO PROMEDIO
Unid. Unid. Unid.
ARITMTICO ARITMTICO ARITMTICO
FLUJO VOLUMTRICO (A) Nm3/h 631222.12 Nm3/h 26141.16 Nm3/h 69474.31
PARTCULAS (B) mg/Nm3 1.92 0.337 g/s mg/Nm3 5.27 0.038 g/s mg/Nm3 3.12 0.060 g/s
HIERRO mg/Nm3 0.65 0.114 g/s mg/Nm3 1.74 0.013 g/s mg/Nm3 0.82 0.016 mg/Nm3
VELOCIDAD m/s 18.22 m/s 9.89 m/s 16.49
TIEMPO DE EMISIN h/d 24.00 h/d 24.00 h/d 24.00
FLUJO MASICO kg/h 812698.48 kg/h 34263.59 kg/h 93939.19
MONOXIDO DE CARBONO mg/Nm3 317.94 55.747 g/s mg/Nm3 0.78 0.006 g/s mg/Nm3 73.81 1.424 g/s
XIDOS DE NITRGENO mg/Nm3 6.16 1.080 g/s mg/Nm3 166.42 1.208 g/s mg/Nm3 60.63 1.170 g/s
DIXIDO DE AZUFRE mg/Nm3 0.00 0.000 g/s mg/Nm3 0.00 0.000 g/s mg/Nm3 502.98 9.707 g/s

PARMETROS COMPLEMENTARIOS
OXIGENO % O2 19.70 % O2 10.47 % O2 14.68
TEMPERATURA DE GASES C 106.57 379.570 K C 332.10 605.100 K C 170.37 443.370 K
TEMPERATURA AMBIENTE C 29.30 302.300 K C 24.40 297.400 K C 30.50 303.500 K
DIXIDO DE CARBONO % 0.68 % 5.87 % 5.99
EXCESO DE AIRE % 1434.00 89.00 228.87
EFICIENCIA DE COMBUSTIN % 51.87 % 72.73 % 81.93

ALTURA DE CHIMENEA m 16.50 m 25.00 m 29.00


DIMETRO EQUIVALENTE m 4.20 m 1.50 m 1.60

Environmental Hygiene & Safety SRL Pg. N 25


Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

Cuadro N 12 Resultados de Reporte de informe de Monitoreo de Emisiones Atmosfricas - Febrero 2013


EMPRESA ACEROS AREQUIPA S.A. SEDE N2 PISCO
HORNO DE ACERIA HORNO DE LAMINACIN HORNO DE HIERRO ESPONJA
FECHA FECHA FECHA
FEBRERO 2013 DE 05/02/2013 DE 06/02/2013 DE 07/02/2013
MONIT.: TASA DE MONIT.: TASA DE MONIT.: TASA DE
Unid. Unid. Unid.
EMISION EMISION EMISION
PROMEDIO PROMEDIO PROMEDIO
Unid. Unid. Unid.
ARITMTICO ARITMTICO ARITMTICO
FLUJO VOLUMTRICO (A) Nm3/h 610497.68 Nm3/h 26901.23 Nm3/h 64076.12
PARTCULAS (B) mg/Nm3 1.13 0.192 g/s mg/Nm3 1.00 0.007 g/s mg/Nm3 8.78 0.156 g/s
HIERRO mg/Nm3 0.47 0.080 g/s mg/Nm3 0.72 0.005 g/s mg/Nm3 2.79 0.050 g/s
VELOCIDAD m/s 17.71 m/s 9.26 m/s 15.62
TIEMPO DE EMISIN h/d 24.00 h/d 24.00 h/d 24.00
FLUJO MASICO kg/h 786015.77 kg/h 35259.83 kg/h 86640.07
MONOXIDO DE CARBONO mg/Nm3 210.02 35.616 g/s mg/Nm3 1.88 0.014 g/s mg/Nm3 64.88 1.155 g/s
XIDOS DE NITRGENO mg/Nm3 2.74 0.465 g/s mg/Nm3 162.77 1.216 g/s mg/Nm3 61.50 1.095 g/s
DIXIDO DE AZUFRE mg/Nm3 0.00 0.000 g/s mg/Nm3 0.00 0.000 g/s mg/Nm3 510.66 9.089 g/s

PARMETROS
COMPLEMENTARIOS
OXIGENO % O2 19.44 % O2 12.13 % O2 15.54
TEMPERATURA DE GASES C 112.20 385.200 K C 301.27 574.270 K C 159.27 432.270 K
TEMPERATURA AMBIENTE C 31.03 304.030 K C 26.40 299.400 K C 29.10 302.100 K
DIXIDO DE CARBONO % 0.85 % 4.94 % 5.17
EXCESO DE AIRE % 1203.77 127.00 280.80
EFICIENCIA DE COMBUSTIN % 56.27 % 71.60 % 80.77

ALTURA DE CHIMENEA m 16.50 m 25.00 m 29.00


DIMETRO EQUIVALENTE m 4.20 m 1.50 m 1.60

Environmental Hygiene & Safety SRL Pg. N 26


Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

Cuadro N 13 Resultados de Reporte de informe de Monitoreo de Emisiones Atmosfricas - Marzo 2013


EMPRESA ACEROS AREQUIPA S.A. SEDE N2 PISCO

HORNO DE ACERIA HORNO DE LAMINACIN HORNO DE HIERRO ESPONJA

FECHA FECHA FECHA


MARZO 2013 DE 07/03/2013 DE 06/03/2013 DE 08/03/2013
MONIT.: TASA DE MONIT.: TASA DE MONIT.: TASA DE
Unid. Unid. Unid.
EMISION EMISION EMISION
PROMEDIO PROMEDIO PROMEDIO
Unid. Unid. Unid.
ARITMTICO ARITMTICO ARITMTICO
FLUJO VOLUMTRICO (A) Nm3/h 627279.67 Nm3/h 23900.54 Nm3/h 53810.13
PARTCULAS (B) mg/Nm3 23.31 4.062 g/s mg/Nm3 4.13 0.027 g/s mg/Nm3 8.77 0.131 g/s
HIERRO mg/Nm3 0.39 0.068 g/s mg/Nm3 2.68 0.018 g/s mg/Nm3 0.78 0.012 g/s
VELOCIDAD m/s 17.73 m/s 8.74 m/s 11.61
TIEMPO DE EMISIN h/d 24.00 h/d 24.00 h/d 24.00
FLUJO MASICO kg/h 807622.58 kg/h 31326.78 kg/h 72758.99
MONOXIDO DE CARBONO mg/Nm3 87.09 15.175 g/s mg/Nm3 0.88 0.006 g/s mg/Nm3 78.42 1.172 g/s
XIDOS DE NITRGENO mg/Nm3 2.05 0.357 g/s mg/Nm3 146.95 0.976 g/s mg/Nm3 75.63 1.130 g/s
DIXIDO DE AZUFRE mg/Nm3 0.00 0.000 g/s mg/Nm3 0.00 0.000 g/s mg/Nm3 654.36 9.781 g/s

PARMETROS
COMPLEMENTARIOS
OXIGENO % O2 20.56 % O2 11.70 % O2 17.43
TEMPERATURA DE GASES C 94.67 367.670 K C 282.87 555.870 K C 135.20 408.200 K
TEMPERATURA AMBIENTE C 35.80 308.800 K C 31.50 304.500 K C 29.40 302.400 K
DIXIDO DE CARBONO % 0.76 % 5.18 % 3.38
EXCESO DE AIRE % 911.23 113.07 487.97
EFICIENCIA DE COMBUSTIN % 57.67 % 73.87 % 76.87

ALTURA DE CHIMENEA m 16.50 m 25.00 m 29.00


DIMETRO EQUIVALENTE m 4.20 m 1.50 m 1.60

Environmental Hygiene & Safety SRL Pg. N 27


Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013
1.10. MODELO DE DISPERSIN SCREEN

SCREEN es un modelo de dispersin de contaminantes atmosfricos


desarrollado por la Agencia de Proteccin Ambiental de Estados Unidos
(USEPA, por sus siglas en ingls).

El programa SCREEN es un modelo de dispersin de tipo gaussiano, que


emplea como entradas variables meteorolgicas y de propagacin, y expone
como salida resultados en forma tabular.

La ecuacin bsica para determinacin la concentracin de contaminantes de


acuerdo a la estructura matemtica gaussiana est dada por la relacin:

..(1)

Dnde:

C = concentracin del contaminante en el punto x, y, z (kg/m3)

Q=masa emitida por unidad de tiempo (kg/seg)

y=coeficientes de dispersin de contaminantes en direccin y (horizontal) (m)

z=coeficientes de dispersin de contaminantes en direccin z (vertical) (m)

u=velocidad del viento (m/s).

y=distancia en direccin horizontal

z=distancia en direccin vertical

h=Altura de la fuente emisora sobre el nivel del suelo ms la elevacin de la


pluma (m).

En forma tpica, la modelizacin gaussiana se aplica sobre fuentes puntuales


como son chimeneas de descarga, hornos industriales, y dems procesos de
combustin con dispositivos relacionados. El ascenso de la pluma, se debe en
parte al empuje trmico de los gases calientes. ste, se define por medio de la
siguiente expresin matemtica.
1.6 1/3
= .(2)

F, flujo de flotabilidad o empuje trmico a la salida de la fuente.


Xf, Distancia aguas abajo a partir de la cota mxima de la elevacin del
penacho.
h, Altura de la columna de humo o elevacin de pluma
Hs, Altura de Chimenea

Pg. N 28
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

El parmetro H, Altura final de la pluma o altura efectiva de chimenea,


corresponde a la sumatoria entre la altura de la chimenea y el incremento
asociado al flujo de flotabilidad, y se define por medio de la expresin.

H= Hs + h ..(3)

De esta manera, el modelo gaussiano expresado por (1) se convierte en:

..(4)

FIGURA N 3 Representacin esquemtica de la pluma gausiana


(Fuente: Turner 1970)

Si se usa meteorologa completa con el arreglo de distancias automtico,


SCREEN imprime las concentraciones mximas para cada distancia, y el
mximo total y su correspondiente distancia. La concentracin total mxima de
SCREEN representa el valor de control de 1 hora.

Pg. N 29
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

Las condiciones de estabilidad que se usa en los clculos POR SCREEN son
los subconjunto A, B, C D, E o F.

Cuadro N 14 Clases de atmsfera segn su estabilidad (Turner)

Finalmente se grafican automticamente los resultados de la concentracin en


funcin de la lnea central de la direccin del viento.

2. PROCESAMIENTO Y RESULTADOS DE DATOS PROVENIENTES DE LAS


FUENTES DE HORNOS

Para el ingreso de datos al modelo de dispersin SCREEN3 se ha optado


ingresar los valores promedios de los resultados registrados desde los
meses de Octubre 2012 a Marzo del 2013.

- Horno de Acera
- Horno de Laminacin
- Horno de Hierro Esponja

Pg. N 30
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013
2.1. HORNO DE ACERIA

2.1.1. Datos de Ingreso del Horno Acera al modelo de dispersin

Tabla N 1 Datos Promedio de entrada para Modelacin en el


Horno de Acera (Octubre 2012 Marzo 2013)

DATOS PROM.
HORNO DE ACERA
(OCT. 2012 MAR 2013)

TIPO DE FUENTE DE PUNTO


PARTCULAS (PTS) 0.858

TASA DE HIERRO (Fe) 0.060


EMISION MONOXIDO DE CARBONO (CO) 44.427
(g/s)
XIDOS DE NITRGENO (NOX) 1.127
DIXIDO DE AZUFRE (SO2) 0.056
ALTURA DE CHIMENEA (m) 16.5
DIAMETRO INTERIOR DE LA CHIMENEA (m) 4.2
VELOCIDAD DE SALIDA DE LOS GASES (m/s) 18.04
TEMPERATURA DE SALIDA DE LOS GASES (K) 375.845
TEMPERATURA AMBIENTE (K) 302.688
ALTURA DE RECEPTOR 102(m) 1.65
OPCION URBANA / RURAL RURAL
OPCIN DE METEREOLOGIA Clase de Estabilidad C
RADIACIN NETA (Aproximada) W/m2 204.16

Pg. N 31
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013
2.1.2. Perfil de elevacin en el entorno del Horno de Acera

2.1.3. Calculo de Altura Efectiva de chimenea (H)


Resultados

Fluctuaciones de Momento y Flotabilidad


Fb= Fluctuacin de flotabilidad Briggs (flujo ascensional especifico inicial de la columan emitida) 151.850 m4/s3
Fm= Fluctuacin de Momento (elevacin de la pluma debido al impulso de la pluma) 1155.84 m4/s2
xf= Distancia aguas abajo a partir de la cota mxima de la elevacin del penacho ______ 887.39 m
h= Altura de la columna de humo o elevacin de pluma _______________________________ 98.01 m

H= Altura final de la pluma o altura efectiva de chimenea ___________________ 114.5 m

Descripcion: HORNO DE ACERIA


Empresa: Aceros Arequipa Sede N2 Pisco

h = 98.01 m

H= 114.5 m

Hs= 16.5 m

A continuacin se muestran los Mapas de los Modelos de Dispersin con sus


respectivas concentraciones de Partculas (PTS, Fe) y Gases (CO, NO, SO 2),
asimismo en el Anexo N4 se adjunta los reportes de salida del modelo SCREEN3
Pg. N 32
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

MAPA N 2 Modelo de dispersin de Chimenea Horno de Acera Concentracin de Partculas PTS

Pg. N 33
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

2.1.4. Anlisis de Pluma y Dispersin de Concentracin de Partculas PTS en Horno de Acera

FIGURA N 4 Anlisis de Pluma y Dispersin de Concentracin de Partculas PTS de Horno Acera

220m Anlisis de Pluma y Dispersin de Concentracin de Partculas PTS (ug/m 3 ) - Horno de Acera
Viento 210m Octubre 2012 - Marzo 2013
200m

185m

160m

140m
PLUMA
120m

115m

110m

0.56ug/m3
107m

102m
h= 98 m
100m

98m

0.58ug/m3
95m

H= 114.51 m

1.66 ug/m3

0.95 ug/m3
92m

0.98 ug/m3
1..009 ug/m3
90m

1.06 ug/m3
1.059 ug/m3
1.019 ug/m3
0.013ug/m

88m

0.90 ug/m3
0.93 ug/m3
0.067ug/m

85m

0.77ug/m3
0.61ug/m3
82m
0.52ug/m3
Hs= 16.5 m
Lindero de CAASA

0.30ug/m3

80m
0.17ug/m3
Carretera

78m

HORNO DE ACERIA 74m


72m

0km 0.25km 0.5 0.6 0.7 0.75 0.8 0.9 1.0 1.20 1.25 1.4 1.5 1.6 1.7 1.75 2.0 2.1 2.2 2.25 2.5 2.75 3.0km

Pg. N 34
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

FIGURA N 5 Concentracin de Partculas PTS Vs Distancia


Concentracin ug/m3

Distancia (km)

Cuadro N15 Resultados de Mxima Concentracin de Partculas PTSHorno Acera

Altura de Mxima Mxima Mxima Mxima


Distancia
terreno Concent. 1Hr Concent. 3Hr Concent. 8Hr Concent. 24Hr
Mxima (m)
(m) (ug/m3) (ug/m3) (ug/m3) (ug/m3)

1640 16 1.06265 0.956385 0.743855 0.42506

2060 17 1.66777 0.667108

(1)
LIMITE REFERENCIAL PTS ((1) Registro Ministerial 315 -96 EM / VMM) 350.00

2.1.5. Resultados del Anlisis de Pluma y Dispersin de Concentracin de


Partculas PTS proveniente del Horno de Acera

De acuerdo a los resultados de la pluma de dispersin atmosfrica de las


emisiones emitida por el Horno de Acera, se concluye lo siguiente:

De las Figuras N4, N5, Mapa N2 y Cuadro N15 se observa que las
concentraciones de partculas emitidas, por la Chimenea se desplazan en
direccin de Oeste a Este (Barlovento Sotavento de la chimenea).
La altura final de la pluma de la chimenea para el Horno de Acera es de
114.5m.
Se observa del Modelo de dispersin, que a 1640m y 2060m equidistantes
de la fuente del Horno de Acera, se generan mayores concentraciones de
partculas, cuyas concentraciones son de 1.06265ug/m3 y 1.66777ug/m3
respectivamente.
EL desplazamiento de vientos, erosin elica y la presencia de relieves que
presenta la zona (quebradas y elevaciones), estos influyen en la
suspensin de partculas en el aire.

Pg. N 35
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

MAPA N 3 Modelo de dispersin de Chimenea Horno de Acera Concentracin de Partculas de Hierro (Fe)

Pg. N 36
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

2.1.6. Anlisis de Pluma y Dispersin de Concentracin de Partculas de Hierro (Fe) en Horno de Acera

FIGURA N 6 Anlisis de Pluma y Dispersin de Concentracin de Partculas de Hierro (Fe) de Horno Acera

220m Anlisis de Pluma y Dispersin de Concentracin de Partculas de Fe (ug/m 3 ) - Horno de Acera


Viento 210m Octubre 2012 - Marzo 2013
200m

185m

160m

140m
PLUMA
120m

115m

110m

0.03 4 ug/m3
107m

102m
h= 98 m
100m

0.036 ug/m3
98m

95m

0.069 ug/m3

0.066ug/m3
H= 114.51 m

0.068 ug/m3
92m

0.074 ug/m3

0.070ug/m3
90m

0.074 ug/m3
0.0 09 ug/m3

0.071 ug/m3
88m

0.063 ug/m3
0.0047ug/m3

0.065 ug/m3
85m

0.054ug/m
0.04ug/m3
0.036ug/m3
82m
0.021ug/m3

Hs= 16.5 m
Lindero de CAASA

0.011ug/m3

80m
Carretera

78m

HORNO DE ACERIA 74m


72m

0km 0.25km 0.5 0.6 0.7 0.75 0.8 0.9 1.0 1.20 1.25 1.4 1.5 1.6 1.7 1.75 2.0 2.1 2.2 2.25 2.5 2.75 3.0km

Pg. N 37
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

FIGURA N 7 Concentracin de Partculas de Hierro (Fe) Vs Distancia


Concentracin ug/m3x10-2

Distancia (km)

Cuadro N16 Resultados de Mxima Concentracin de Partculas de Hierro (Fe)


Horno Acera

Altura de Mxima Mxima Mxima Mxima


Distancia
terreno Concent. 1Hr Concent. 3Hr Concent. 8Hr Concent. 24Hr
Mxima (m)
(m) (ug/m3) (ug/m3) (ug/m3) (ug/m3)

1640 16 0.074311 0.06688 0.052018 0.029724

2060 17 0.069600 0.046651

LIMITE REFERENCIAL Fe ((2)Summary of Point of Impingement Standards, Point of 4.0(2)


Impingement Guidelines and Ambient Air Quality Criteria. Standards Development Branch
Ontario Ministry of the Environment. September 2001.)

2.1.7. Resultados del Anlisis de Pluma y Dispersin de Concentracin de


Partculas de Hierro proveniente del Horno de Acera

De acuerdo a los resultados de la pluma de dispersin atmosfrica de las


emisiones emitida por el Horno de Acera, se concluye lo siguiente:

De las Figuras N6, N7, Mapa N3 y Cuadro N16 se observa que las
concentraciones de partculas emitidas, por la Chimenea se desplazan en
direccin de Oeste a Este (Barlovento Sotavento de la chimenea).
La altura final de la pluma de la chimenea para el Horno de Acera es de
114.51m.
Se observa del Modelo de dispersin, que a 1640m y 2060m equidistantes
de la fuente del Horno de Acera, se generan mayores concentraciones de
partculas de Hierro (Fe), cuyas concentraciones son de 0.074ug/m3 y
0.069ug/m3 respectivamente.

Pg. N 38
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

MAPA N 4 Modelo de dispersin de Chimenea Horno de Acera Concentracin de Monxido de Carbono (CO)

Pg. N 39
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

2.1.8. Anlisis de Pluma y Dispersin de Concentracin de Monxido de Carbono (CO) en Horno de Acera

FIGURA N 8 Anlisis de Pluma y Dispersin de Concentracin de Monxido de Carbono (CO) - Horno Acera

220m Anlisis de Pluma y Dispersin de Concentracin de Monoxido de Carbono CO (ug/m 3 ) - Horno de Acera
Viento 210m Octubre 2012 - Marzo 2013
200m

185m

160m

140m
PLUMA
120m

115m

26.32 ug/m3
110m

107m

102m
h= 98 m

27.04 ug/m3
100m

98m

51.53 ug/m3

49.60 ug/m3
95m

51.00 ug/m3
H= 114.51 m

52.23 ug/m3
92m

55.02 ug/m3
54.85ug/m3
52.75 ug/m3
90m

46.80 ug/m3
0.069 ug/m3

48.21 ug/m3
88m
3.47 ug/m3

40.11 ug/m3
85m

32.05 ug/m3
27.19 ug/m3
82m
15.696 ug/m3

Hs= 16.5 m
Lindero de CAASA

80m
8.85 ug/m3
Carretera

78m

HORNO DE ACERIA 74m


72m

0km 0.25km 0.5 0.6 0.7 0.75 0.8 0.9 1.0 1.20 1.25 1.4 1.5 1.6 1.7 1.75 2.0 2.1 2.2 2.25 2.5 2.75 3.0km

Pg. N 40
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

FIGURA N 9 Concentracin de Monxido de Carbono (CO) Vs Distancia


Concentracin ug/m3x10-1

Distancia (km)

Cuadro N17 Resultados de Mxima Concentracin de Monxido de Carbono (CO)


Horno Acera

Altura de Mxima Mxima Mxima Mxima


Distancia
terreno Concent. 1Hr Concent. 3Hr Concent. 8Hr Concent. 24Hr
Mxima (m)
(m) (ug/m3) (ug/m3) (ug/m3) (ug/m3)

1640 16 55.02 49.52 38.52 22.01

2060 17 51.53 34.54

LIMITE REFERENCIAL CO ((3) D.S. N 003-2008-MINAM Estndares Nacionales de 30000(3)


Calidad Ambiental del Aire)

2.1.9. Resultados del Anlisis de Pluma y Dispersin de Concentracin de


Monxido de carbono proveniente del Horno de Acera

De acuerdo a los resultados de la pluma de dispersin atmosfrica de las


emisiones emitida por el Horno de Acera, se concluye lo siguiente:

De las Figuras N8, N9, Mapa N4 y cuadro N17 se observa que las
concentraciones de partculas emitidas, por la Chimenea se desplazan en
direccin de Oeste a Este (Barlovento Sotavento de la chimenea).
La altura final de la pluma de la chimenea para el Horno de Acera es de
114.51m.
Se observa del Modelo de dispersin, que a 1640m y 2060m equidistantes
de la fuente del Horno de Acera, se generan mayores concentraciones de
Monxido de Carbono (CO), cuyas concentraciones son de 55.02 ug/m3 y
51.53 ug/m3 respectivamente.

Pg. N 41
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

MAPA N 5 Modelo de dispersin de Chimenea Horno de Acera Concentracin de xido de Nitrgeno (NO)

Pg. N 42
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

2.1.10. Anlisis de Pluma y Dispersin de Concentracin de xido de Nitrgeno (NOx) en Horno de Acera

FIGURA N 10 Anlisis de Pluma y Dispersin de Concentracin de xido de Nitrgeno (NOx) - Horno Acera

220m Anlisis de Pluma y Dispersin de Concentracin de Oxido de Nitrogeno NOX (ug/m 3 ) - Horno de Acera
Viento 210m Octubre 2012 - Marzo 2013
200m

185m

160m

140m
PLUMA
120m

115m

0.643 ug/m3
110m

107m

102m
h= 98 m

0.686 ug/m3
100m

98m

1.258 ug/m3
1.307 ug/m3
95m

1.294 ug/m3
H= 114.51 m

1.32 ug/m3
92m

1.396 ug/m3
90m

1.338 ug/m3

1.39 ug/m3
0.017 ug/m3

1.22 ug/m3
1.18 8 ug/m3
88m
0.088 ug/m3

85m

1.016 ug/m3
82m
0.81 ug/m3
0.69 ug/m3

Hs= 16.5 m
Lindero de CAASA

0.40 ug/m3

80m
0.22 ug/m3
Carretera

78m

HORNO DE ACERIA 74m


72m

0km 0.25km 0.5 0.6 0.7 0.75 0.8 0.9 1.0 1.20 1.25 1.4 1.5 1.6 1.7 1.75 2.0 2.1 2.2 2.25 2.5 2.75 3.0km

Pg. N 43
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

FIGURA N11 Concentracin de xido de Nitrgeno (NOx) Vs Distancia


Concentracin ug/m3

Distancia (km)

Cuadro N18 Resultados de Mxima Concentracin de xido de Nitrgeno Horno


Acera

Altura de Mxima Mxima Mxima Mxima


Distancia
terreno Concent. 1Hr Concent. 3Hr Concent. 8Hr Concent. 24Hr
Mxima (m)
(m) (ug/m3) (ug/m3) (ug/m3) (ug/m3)

1640 16 1.39581 1.256229 0.977067 0.558324

2060 17 1.307 0.876259

LIMITE REFERENCIAL NO ((4) D.S. N 003-2008-MINAM Estndares Nacionales de 200(4)


Calidad Ambiental del Aire)

2.1.11. Resultados del Anlisis de Pluma y Dispersin de Concentracin de xido


de Nitrgeno proveniente del Horno de Acera

De acuerdo a los resultados de la pluma de dispersin atmosfrica de las


emisiones emitida por el Horno de Acera, se concluye lo siguiente:

De las Figuras N5, N10, Mapa N5 y cuadro N18 se observa que las
concentraciones de partculas emitidas, por la Chimenea se desplazan en
direccin de Oeste a Este (Barlovento Sotavento de la chimenea).
La altura final de la pluma de la chimenea para el Horno de Acera es de
114.51m.
Se observa del Modelo de dispersin, que a 1640m y 2060m equidistantes de
la fuente del Horno de Acera, se generan mayores concentraciones de xido
de Nitrgeno (NO), cuyas concentraciones son de 1.395 ug/m3 y 1.307 ug/m3
respectivamente.

Pg. N 44
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

MAPA N 6 Modelo de dispersin de Chimenea Horno de Acera Concentracin de Dixido de Azufre (SO2)

Pg. N 45
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

2.1.12. Anlisis de Pluma y Dispersin de Concentracin de Dixido de Azufre (SO2) en Horno de Acera

FIGURA N 12 Anlisis de Pluma y Dispersin de Concentracin de Dixido de Azufre (SO2)- Horno Acera

220m Anlisis de Pluma y Dispersin de Concentracin de Dioxido de Azufre SO2 (ug/m3 ) - Horno de Acera
Viento 210m Octubre 2012 - Marzo 2013
200m

185m

160m

140m
PLUMA
120m

115m

0.032 ug/m3
110m

107m

102m
h= 98 m

0.034 ug/m3
100m

98m

0.062 ug/m3
95m

0.064 ug/m3
0.064 ug/m3
H= 114.51 m

0.065 ug/m3
92m

0.0693 ug/m3
0.069 ug/m3
0.00087 ug/m3

0.066 ug/m3
90m

0.060 ug/m3
0.058 ug/m3
88m
0.0043ug/m3

85m

0.055ug/m3
0.040 ug/m3
0.034 ug/m3
82m
0.020 ug/m3
0.011 ug/m3

Hs= 16.5 m
Lindero de CAASA

80m
Carretera

78m

HORNO DE ACERIA 74m


72m

0km 0.25km 0.5 0.6 0.7 0.75 0.8 0.9 1.0 1.20 1.25 1.4 1.5 1.6 1.7 1.75 2.0 2.1 2.2 2.25 2.5 2.75 3.0km

Pg. N 46
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

FIGURA N13 Concentracin de Dixido de Azufre (SO2) Vs Distancia


Concentracin ug/m3x10-2

Distancia (km)

Cuadro N19 Resultados de Mxima Concentracin de Dixido de Azufre (SO 2)


Horno Acera

Altura de Mxima Mxima Mxima Mxima


Distancia
terreno Concent. 1Hr Concent. 3Hr Concent. 8Hr Concent. 24Hr
Mxima (m)
(m) (ug/m3) (ug/m3) (ug/m3) (ug/m3)

1640 16 0.069357 0.062421 0.04855 0.027743

2060 17 0.0649 0.043541

LIMITE REFERENCIAL NO ((5) D.S. N 003-2008-MINAM Estndares Nacionales de 80(5)


Calidad Ambiental del Aire)

2.1.13. Resultados del Anlisis de Pluma y Dispersin de Concentracin de


Dixido de Azufre proveniente del Horno de Acera

De acuerdo a los resultados de la pluma de dispersin atmosfrica de las


emisiones emitida por el Horno de Acera, se concluye lo siguiente:

De las Figuras N12, N13, Mapa N6 y Cuadro N19 se observa que las
concentraciones de partculas emitidas, por la Chimenea se desplazan en
direccin de Oeste a Este (Barlovento Sotavento de la chimenea).
La altura final de la pluma de la chimenea para el Horno de Acera es de
114.51m.
Se observa del Modelo de dispersin, que a 1640m y 2060m equidistantes
de la fuente del Horno de Acera, se generan mayores concentraciones de
Dixido de Azufre (SO2), cuyas concentraciones son de 0.069 ug/m3 y
0.064 ug/m3 respectivamente.

Pg. N 47
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

2.1.14. Resultados de concentraciones segn tipo de contaminantes proveniente


del Horno de Acera

A continuacin se muestra los resultados del modelo gaussiano aplicado, proveniente del
Horno de Acera descrito en la seccin anterior, en donde las concentraciones emitidas
estn en funcin de la distancia a la fuente emisora, con una distancia de hasta 3 km.

Grfico N 3 Concentraciones segn Contaminantes provenientes del Horno


de Acera

De la Tabla N1(Datos Promedios), se observa que la tasa de emisin de CO


(44.427 g/s) es mayor que las tasas de PTS (44.427 g/s), Fe (44.427 g/s), NO
(44.427 g/s) y SO2 (44.427 g/s), dichas cantidades coinciden con los resultados
obtenidos en el modelo gaussiano (ver grfico N3), y cuyas concentraciones de
CO (55.02ug/m3), es mayor de las concentraciones de PTS (1.06ug/m3), Fe
(0.07ug/m3), SO2(0.065ug/m3) y NO(1.32 ug/m3).

Asimismo se observa del grfico N3 que a 1640m de distancia de la fuente se


genera las mximas concentraciones de PTS, Fe, CO, NO, SO2 proveniente del
Horno de Acera.

Pg. N 48
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

2.2. HORNO DE LAMINACIN

2.2.1. Datos de Ingreso del Horno de Laminacin al modelo de dispersin

Tabla N 2 Datos Promedio de entrada para Modelacin en el Horno de


Laminacin (Octubre 2012 Marzo 2013)
DATOS PROM. (OCT.
HORNO DE LAMINACIN
2012 MAR 2013)

TIPO DE FUENTE DE PUNTO

PARTCULAS (PTS) 0.079

HIERRO (Fe) 0.01


TASA DE
EMISION MONOXIDO DE CARBONO (CO) 0.036
(g/s)
XIDOS DE NITRGENO (NOX) 1.300

DIXIDO DE AZUFRE (SO2) ---

ALTURA DE CHIMENEA (m) 25

DIAMETRO INTERIOR DE LA CHIMENEA (m) 1.5

VELOCIDAD DE SALIDA DE LOS GASES (m/s) 10.985

TEMPERATURA DE SALIDA DE LOS GASES (K) 604.857

TEMPERATURA AMBIENTE (K) 298.750

OPCION URBANA / RURAL RURAL

OPCIN DE METEREOLOGIA Meteorologa completa

Pg. N 49
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

2.2.2. Perfil de elevacin en el entorno del Horno de laminacin

2.2.3. Calculo de Altura Efectiva de chimenea (H)


Fluctuaciones de Momento y Flotabilidad
Fb= Fluctuacin de flotabilidad Briggs (flujo ascensional especifico inicial de la columan emitida) 30.664 m4/s3
Fm= Fluctuacin de Momento (elevacin de la pluma debido al impulso de la pluma) 33.526 m4/s2
xf= Distancia aguas abajo a partir de la cota mxima de la elevacin del penacho ______ 416.24 m
h= Altura de la columna de humo o elevacin de pluma_______________________________ 57.33 m

H= Altura final de la pluma o altura efectiva de chimenea ___________________ 82.3 m

Descripcion: HORNO DE LAMINACIN


Empresa: Aceros Arequipa Sede N2 Pisco

h = 57.33 m

H= 82.3 m

Hs= 25 m

Pg. N 50
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

MAPA N 7 Modelo de dispersin de Chimenea Horno de Laminacin concentracin de Partculas PTS

Pg. N 51
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

2.2.4. Anlisis de Pluma y Dispersin de Concentracin de Partculas PTS en Horno de Laminacin

FIGURA N 14 Anlisis de Pluma y Dispersin de Concentracin de Partculas PTS de Horno de Laminacin

Anlisis de Pluma y Dispersin de Concentracin de Partculas PTS (ug/m 3 ) - Horno de Laminacin


170m Octubre 2012 - Marzo 2013
Viento 165m

160m

150m

140m

130m

120m PLUMA
115m

110m

107m

0.10 ug/m3
102m
h = 57.3 m

0.11 ug/m3
100m

0.12 ug/m3
0.13 ug/m3
98m

95m

0.15 ug/m3
0.17 ug/m3
92m

0.19ug/m3
90m

0.22 ug/m3
0.029ug/m3

0.25 ug/m3
88m

0.27 ug/m3
H= 82.33 m

0.3279 ug/m3
85m
0.386 ug/m3

0.370ug/m3
82m
0.37ug/m3
0.24 ug/m3

0.35 ug/m3
Lindero de CAASA

Hs= 25 m 80m
0.22 ug/m3
Carretera

78m

HORNO DE LAMINACIN 74m

72m

0km 0.25 0.3 0.48 0.5 0.7 0.75 0.8 0.87 1.0 1.2 1.25 1.4 1.5 1.70 1.75 1.90 2.0 2.20 2.25 2.4 2.5 2.7 2.75 2.8 2.9 3.0km

Pg. N 52
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

FIGURA N 15 Concentracin de Partculas PTS Vs Distancia


Concentracin ug/m3 X 10-1

Distancia (km)

Cuadro N 20 Resultados de Mxima Concentracin de Partculas PTS Horno de


Laminacin

Altura de Mxima Mxima Mxima Mxima


Distancia
terreno Concent. 1Hr Concent. 3Hr Concent. 8Hr Concent. 24Hr
Mxima (m)
(m) (ug/m3) (ug/m3) (ug/m3) (ug/m3)

875 5 0.397465 0.357719 0.278226 0.158986

3000 32 0.06684 0.26736

(1)
LIMITE REFERENCIAL PTS ((1) Registro Ministerial 315 -96 EM / VMM) 350.00

2.2.5. Resultados del Anlisis de Pluma y Dispersin de Concentracin de


Partculas PTS proveniente de Horno de Laminacin

De acuerdo a los resultados de la pluma de dispersin atmosfrica de las


emisiones emitida por el Horno de Laminacin se concluye lo siguiente:

De las Figuras N14, N15, Mapa N7 y Cuadro N20 se observa que las
concentraciones de partculas emitidas, por la Chimenea se desplazan en
direccin de Oeste a Este (Barlovento Sotavento de la chimenea).
La altura final de la pluma de la chimenea para el Horno de Laminacin es de
82.33m.
Se observa del Modelo de Dispersin, que a 875m y 3000m equidistantes de
la fuente del Horno de Laminacin, se generan mayores concentraciones de
partculas PTS, las cuales son de 0.397465ug/m3 y 0.06684ug/m3
respectivamente.
EL desplazamiento de vientos, erosin elica y la presencia de relieves que
presenta la zona (quebradas y elevaciones), estos influyen en la suspensin
de partculas en el aire.
Pg. N 53
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

MAPA N 8 Modelo de dispersin de Chimenea Horno de Laminacin Concentracin de Partculas de Hierro (Fe)

Pg. N 54
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

2.2.6. Anlisis de Pluma y Dispersin de Concentracin de Partculas de Hierro (Fe) en Horno de Laminacin

FIGURA N 16 Anlisis de Pluma y Dispersin de Concentracin de Partculas de Hierro (Fe) de Horno de Laminacin

Anlisis de Pluma y Dispersin de Concentracin de Partculas de Hierro Fe (ug/m 3 ) - Horno de Laminacin


170m
Octubre 2012 - Marzo 2013
Viento 165m

160m

150m

140m

130m

120m PLUMA
115m

110m

107m

0.013 ug/m3
102m
h = 57.3 m

0.014 ug/m3
0.015 ug/m3
100m

0.016 ug/m3
98m

95m

0.019 ug/m3
0.022 ug/m3
92m

0.024 ug/m3
0.028 ug/m3
0.0037ug/m3

90m

0.032ug/m
88m

0.035 ug/m3
H= 82.33 m

0.040 ug/m3
85m

0.0469 ug/m3
0.048ug/m3
82m 0.050 ug/m3
0.031 ug/m3

0.044 ug/m3
Lindero de CAASA

Hs= 25 m 80m
0.028 ug/m3
Carretera

78m

HORNO DE LAMINACIN 74m

72m

0km 0.25 0.3 0.48 0.5 0.7 0.75 0.8 0.87 1.0 1.2 1.25 1.4 1.5 1.70 1.75 1.90 2.0 2.20 2.25 2.4 2.5 2.7 2.75 2.8 2.9 3.0km

Pg. N 55
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

FIGURA N 17 Concentracin de Partculas de Hierro (Fe) Vs Distancia


Concentracin ug/m3 x10-2

Distancia (km)

Cuadro N21 Resultados de Mxima Concentracin de Partculas Hierro Horno de


Laminacin

Altura de Mxima Mxima Mxima Mxima


Distancia
terreno Concent. 1Hr Concent. 3Hr Concent. 8Hr Concent. 24Hr
Mxima (m)
(m) (ug/m3) (ug/m3) (ug/m3) (ug/m3)

875 5 0.050312 0.045281 0.035218 0.020125

3000 32 0.084607 0.033843

LIMITE REFERENCIAL Fe ((2)Summary of Point of Impingement Standards, Point of 4.0(2)


Impingement Guidelines and Ambient Air Quality Criteria. Standards Development Branch
Ontario Ministry of the Environment. September 2001.)

2.2.7. Resultados del Anlisis de Pluma y Dispersin de Concentracin de


Partculas de Hierro proveniente del Horno de Laminacin

De acuerdo a los resultados de la pluma de dispersin atmosfrica de las


emisiones emitida por el Horno de Laminacin se concluye lo siguiente:

De las Figuras N16, N17, Mapa N8 y Cuadro N21 se observa que las
concentraciones de partculas emitidas, por la Chimenea se desplazan en
direccin de Oeste a Este (Barlovento Sotavento de la chimenea).
La altura final de la pluma de la chimenea para el Horno de Laminacin es
de 82.33m.
Se observa del Modelo de Dispersin, que a 875m y 3000m equidistantes
de la fuente del Horno de Laminacin, se generan mayores
concentraciones de partculas de Hierro (Fe), las cuales son de 0.050 g/m3
y 0.0846 ug/m3 respectivamente.

Pg. N 56
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

MAPA N 9 Modelo de dispersin de Chimenea Horno de Laminacin Concentracin de Monxido de Carbono (CO)

Pg. N 57
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

2.2.8. Anlisis de Pluma y Dispersin de Concentracin de Monxido de Carbono (CO) en Horno de Laminacin

FIGURA N 18 Anlisis de Pluma y Dispersin de Concentracin de Monxido de Carbono (CO) - Horno de Laminacin

Anlisis de Pluma y Dispersin de Concentracin de Monoxido de Carbono CO (ug/m 3 ) - Horno de Laminacin


170m
Octubre 2012 - Marzo 2013
Viento 165m

160m

150m

140m

130m

120m PLUMA
115m

110m

107m

0.0479 ug/m3
102m

0.0508 ug/m3
h = 57.3 m

0.0567 ug/m3
100m

0.060 ug/m3
98m

95m

0.069 ug/m3
0.080 ug/m3
92m

0.086 ug/m3
0.102 ug/m3
90m
0.013 ug/m3

0.116 ug/m3
88m

0.126 ug/m3
H= 82.33 m

0.149 ug/m3
85m

0.169 ug/m3
0.175 ug/m3
82m 0.18 1 ug/m3
0.11 ug/m3

0.16 ug/m3
Lindero de CAASA

Hs= 25 m 80m
0.10 ug/m3
Carretera

78m

HORNO DE LAMINACIN 74m

72m

0km 0.25 0.3 0.48 0.5 0.7 0.75 0.8 0.87 1.0 1.2 1.25 1.4 1.5 1.70 1.75 1.90 2.0 2.20 2.25 2.4 2.5 2.7 2.75 2.8 2.9 3.0km

Pg. N 58
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

FIGURA N 19 Concentracin de Monxido de carbono (CO) Vs Distancia


Concentracin ug/m3X10-1

Distancia (km)

Cuadro N22 Resultados de Mxima Concentracin de Monxido de Carbono (CO)


Horno de Laminacin

Altura de Mxima Mxima Mxima Mxima


Distancia
terreno Concent. 1Hr Concent. 3Hr Concent. 8Hr Concent. 24Hr
Mxima (m)
(m) (ug/m3) (ug/m3) (ug/m3) (ug/m3)

875 5 0.181123 0.163011 0.126786 0.072449

3000 32 0.304588 0.121835

LIMITE REFERENCIAL CO ((3) D.S. N 003-2008-MINAM Estndares Nacionales de 30000(3)


Calidad Ambiental del Aire)

2.2.9. Resultados del Anlisis de Pluma y Dispersin de Concentracin de


Monxido de Carbono proveniente del Horno de Laminacin

De acuerdo a los resultados de la pluma de dispersin atmosfrica de las


emisiones emitida por el Horno de Laminacin se concluye lo siguiente:

De las Figuras N18, N19, Mapa N9 y Cuadro N22 se observa que las
concentraciones de partculas emitidas, por la Chimenea se desplazan en
direccin de Oeste a Este (Barlovento Sotavento de la chimenea).
La altura final de la pluma de la chimenea para el Horno de Laminacin es
de 82.33m.
Se observa del Modelo de Dispersin, que a 875m y 3000m equidistantes
de la fuente del Horno de Laminacin, se generan mayores
concentraciones de Monxido de Carbono (CO), las cuales son de 0.1811
ug/m3 y 0.3045 ug/m3 respectivamente.

Pg. N 59
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

MAPA N 10 Modelo de dispersin de Chimenea Horno de Laminacin Concentracin de xido de Nitrgeno (NOx)

Pg. N 60
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

2.2.10. Anlisis de Pluma y Dispersin de Concentracin de xido de Nitrgeno (NOx) en Horno de Laminacin

FIGURA N 20 Anlisis de Pluma y Dispersin de Concentracin de xido de Nitrgeno (NO) - Horno de Laminacin

Anlisis de Pluma y Dispersin de Concentracin de Oxido de Nitrogeno NO (ug/m 3 ) - Horno de Laminacin


170m
Octubre 2012 - Marzo 2013
Viento 165m

160m

150m

140m

130m

120m PLUMA
115m

110m

107m

1.733 ug/m3
102m
h = 57.3 m

1.836 ug/m3
2.051 ug/m3
100m

2.192 ug/m3
98m

95m

2.523 ug/m3
2.893 ug/m3
92m

3.128 ug/m3
3.687 ug/m3
0.480 ug/m3

90m

4.217 ug/m3
88m

4.552 ug/m3
H= 82.33 m

5.259 ug/m3
85m
6.102 ug/m3
6.352 ug/m3
6.540 ug/m3
4.076 ug/m3

82m
5.835 ug/m3
Lindero de CAASA

Hs= 25 m
3.690 ug/m3

80m
Carretera

78m

HORNO DE LAMINACIN 74m

72m

0km 0.25 0.3 0.48 0.5 0.7 0.75 0.8 0.87 1.0 1.2 1.25 1.4 1.5 1.70 1.75 1.90 2.0 2.20 2.25 2.4 2.5 2.7 2.75 2.8 2.9 3.0km

Pg. N 61
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

Concentracin ug/m3 FIGURA N21 Concentracin de xido de Nitrgeno (NOx) Vs Distancia

Distancia (km)

Cuadro N23 Resultados de Mxima Concentracin de xido de Nitrgeno Horno de


Laminacin

Altura de Mxima Mxima Mxima Mxima


Distancia
terreno Concent. 1Hr Concent. 3Hr Concent. 8Hr Concent. 24Hr
Mxima (m)
(m) (ug/m3) (ug/m3) (ug/m3) (ug/m3)

875 5 6.54057 5.886513 4.578399 2.616228

3000 32 10.998975 4.39959

LIMITE REFERENCIAL NO ((4) D.S. N 003-2008-MINAM Estndares Nacionales de 200(4)


Calidad Ambiental del Aire)

2.2.11. Resultados del Anlisis de Pluma y Dispersin de Concentracin de xido


de Nitrgeno proveniente del Horno de Laminacin

De acuerdo a los resultados de la pluma de dispersin atmosfrica de las


emisiones emitida por el Horno de Laminacin se concluye lo siguiente:

De las Figuras N20, N21, Mapa N10 y Cuadro N23 se observa que las
concentraciones de partculas emitidas, por la Chimenea se desplazan en
direccin de Oeste a Este (Barlovento Sotavento de la chimenea).
La altura final de la pluma de la chimenea para el Horno de Laminacin es de
82.33m.
Se observa del Modelo de Dispersin, que a 875m y 3000m equidistantes de
la fuente del Horno de Laminacin, se generan mayores concentraciones de
xido de Nitrgeno (NO), las cuales son de 6.54 g/m3 y 10.99 ug/m3
respectivamente.

Pg. N 62
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

2.2.12. Resultados de concentraciones segn tipo de contaminantes proveniente


del Horno de Laminacin

A continuacin se muestra los resultados del modelo gaussiano aplicado,


proveniente del Horno de Acera descrito en la seccin anterior, en donde las
concentraciones emitidas estn en funcin de la distancia a la fuente emisora, con
una distancia de hasta 3 km.

Grfico N 4 Concentraciones segn Contaminantes provenientes del


Horno de Laminacin

De la Tabla N1(Datos Promedios), se observa que la tasa de emisin de NO (1.3


g/s) es mayor que las tasas de PTS (0.079 g/s), Fe (0.01 g/s) y CO (0.036 g/s),
dichas cantidades coinciden con los resultados obtenidos en el modelo gaussiano
(ver grfico N4), y cuyas concentraciones de NO (6.541ug/m3), es mayor de las
concentraciones de PTS (0.39ug/m3), Fe (0.503ug/m3) y CO(0.181 ug/m3).

Asimismo se observa del grfico N4 que a 870m de distancia de la fuente se genera


las mximas concentraciones de PTS, Fe, CO, NO, SO2 proveniente del Horno de
Laminacin.

Pg. N 63
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

2.3. HORNO DE HIERRO ESPONJA

2.3.1. Datos de Ingreso del Horno Hierro Esponja al modelo de dispersin

Tabla N 3 Datos Promedio de entrada para Modelacin en el Horno de


Hierro Esponja (Octubre 2012 Marzo 2013)

DATOS PROM. (OCT.


HORNO DE HIERRO ESPONJA
2012 MAR 2013)

TIPO DE FUENTE DE PUNTO

PARTCULAS (PTS) 1.288

FIERRO (Fe) 0.046


TASA DE
EMISION MONOXIDO DE CARBONO (CO) 1.262
(g/s)
XIDOS DE NITRGENO (NOX) 1.130

DIXIDO DE AZUFRE (SO2) 9.533

ALTURA DE CHIMENEA (m) 29.000

DIAMETRO INTERIOR DE LA CHIMENEA (m) 1.600

VELOCIDAD DE SALIDA DE LOS GASES (m/s) 14.335

TEMPERATURA DE SALIDA DE LOS GASES (K) 438.623

TEMPERATURA AMBIENTE (K) 299.717

ALTURA DE RECEPTOR (m) 1.65

OPCION URBANA / RURAL RURAL

OPCIN DE METEREOLOGIA Clase de Estabilidad C

RADIACIN NETA (Aproximada) W/m2 204.16

Pg. N 64
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

2.3.2. Perfil de elevacin en el entorno del Horno de Hierro Esponja

Pg. N 65
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

2.3.3. Calculo de Altura Efectiva de chimenea (H)


Resultados

Fluctuaciones de Momento y Flotabilidad


Fb= Fluctuacin de flotabilidad Briggs (flujo ascensional especifico inicial de la columan emitida) 28.490 m4/s3
Fm= Fluctuacin de Momento (elevacin de la pluma debido al impulso de la pluma) 89.866 m4/s2
xf= Distancia aguas abajo a partir de la cota mxima de la elevacin del penacho ______ 397.54 m
h= Altura de la columna de humo o elevacin de pluma_______________________________ 55.04 m

H= Altura final de la pluma o altura efectiva de chimenea ___________________ 84.04 m

Descripcion: HORNO DE HIERRO ESPONJA


Empresa: Aceros Arequipa Sede N2 Pisco

h = 55.04 m

H= 84.0 m

Hs= 29 m

Pg. N 66
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

MAPA N 11 Modelo de dispersin de Chimenea Horno de Hierro Esponja concentracin de Partculas PTS

Pg. N 67
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013
2.3.4. Anlisis de Pluma y Dispersin de Concentracin de Partculas PTS en Horno de Hierro Esponja

FIGURA N 22 Anlisis de Pluma y Dispersin de Concentracin de Partculas PTS de Horno de Hierro Esponja

Anlisis de Pluma y Dispersin de Concentracin de Partculas PTS (ug/m 3 ) - Horno de Hierro Esponja
Viento
180m
Octubre 2012 - Marzo 2013
170m

160m

150m

140m

130m PLUMA
120m

115m

1.51ug/m3
110m

1.604 ug/m3
h= 55 m 107m

1.814 ug/m3
103m
102m

2.070 ug/m3
2.219 ug/m3
100m

98m

2.469 ug/m3
2.872 ug/m3
3.110 ug/m3
95m

92m

3.857 ug/m3
90m
3.497 ug/m3
4.399 ug/m3

H= 84.04 m

4.207 ug/m3
88m

4.816 ug/m3
5.237 ug/m3
Hs= 29 m 85m

5.898ug/m3
6.228 ug/m3
82m
5.758 ug/m3
5.541 ug/m3
Lindero de CAASA

80m
Carretera

78m
HORNO DE HIERRO ESPONJA
74m

73m

0km 0.25km 0.5 0.57 0.70.75 0.8 0.9 1.0 1.2 1.25 1.3 1.5 1.6 1.75 1.9 2.0 2.2 2.25 2.4 2.5 2.7 2.75 2.9 3.0km

Pg. N 68
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

FIGURA N 23 Concentracin de Partculas PTS Vs Distancia


Concentracin ug/m3

Distancia (km)

Cuadro N 24 Resultados de Mxima Concentracin de Partculas PTSHierro Esponja

Altura de Mxima Mxima Mxima Mxima


Distancia
terreno Concent. 1Hr Concent. 3Hr Concent. 8Hr Concent. 24Hr
Mxima (m)
(m) (ug/m3) (ug/m3) (ug/m3) (ug/m3)

901 16.4 6.22862 5.605758 4.360034 2.491448

3090 104.99 11.690175 4.67607

(1)
LIMITE REFERENCIAL PTS ((1) Registro Ministerial 315 -96 EM / VMM) 350.00

2.3.5. Resultados del Anlisis de Pluma y Dispersin de Concentracin de


Partculas PTS proveniente de Horno de Hierro Esponja

De acuerdo a los resultados de la pluma de dispersin atmosfrica de las


emisiones emitida por el Horno de Hierro Esponja se concluye lo siguiente:

De las Figuras N22, N23, Mapa N11 y Cuadro N24 se observa que las
concentraciones de partculas emitidas, por la Chimenea se desplazan en
direccin de Oeste a Este (Barlovento Sotavento de la chimenea).
La altura final de la pluma de la chimenea para el Horno de Hierro Esponja es
de 84.04m.
Se observa del Modelo de Dispersin, que a 901m y 3090m equidistantes de
la fuente del Horno de Hierro Esponja, se generan mayores concentraciones
de Partculas PTS, las cuales son de 6.228 g/m3 y 11.69 ug/m3
respectivamente.
EL desplazamiento de vientos, erosin elica y la presencia de relieves que
presenta la zona (quebradas y elevaciones), estos influyen en la suspensin
de partculas en el aire.

Pg. N 69
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

MAPA N 12 Modelo de dispersin de Chimenea Horno de Hierro Esponja Concentracin de Partculas de Hierro (Fe)

Pg. N 70
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

2.3.6. Anlisis de Pluma y Dispersin de Concentracin de Partculas de Hierro (Fe) en Horno de Hierro Esponja

FIGURA N 24 Anlisis de Pluma y Dispersin de Concentracin de Partculas de Hierro (Fe) de Horno de Hierro Esponja

Anlisis de Pluma y Dispersin de Concentracin de Partculas de Hierro Fe (ug/m 3 ) - Horno de Hierro Esponja
180m
Viento Octubre 2012 - Marzo 2013
170m

160m

150m

140m

130m PLUMA
120m

115m

0.0540 ug/m3
110m

0.0572 ug/m3
h= 55 m 107m

0.0648 ug/m3
103m

0.07392 ug/m3
102m

0.0792 ug/m3
100m

98m

0.0881 ug/m3
0.1026 ug/m3
0.111 ug/m3
95m

92m

0.1378 ug/m3
90m
0.124 ug/m3
Lindero de CAASA 0.157 ug/m3

H= 84.04 m

0.1502 ug/m3
88m

0.171 ug/m3
0.187 ug/m3
Hs= 29 m 85m

0.210 ug/m3
82m 0.222 ug/m3
0.205 ug/m3
0.197 ug/m3

80m
Carretera

78m
HORNO DE HIERRO ESPONJA
74m

73m

0km 0.25km 0.5 0.57 0.70.75 0.8 0.9 1.0 1.2 1.25 1.35 1.5 1.6 1.75 1.9 2.0 2.2 2.25 2.4 2.5 2.7 2.75 2.9 3.0km

Pg. N 71
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

Concentracin ug/m3x10-1 FIGURA N 25 Concentracin de Partculas de Hierro (Fe) Vs Distancia

Distancia (km)

Cuadro N25 Resultados de Mxima Concentracin de Partculas Hierro Horno de


Hierro Esponja

Altura de Mxima Mxima Mxima Mxima


Distancia
terreno Concent. 1Hr Concent. 3Hr Concent. 8Hr Concent. 24Hr
Mxima (m)
(m) (ug/m3) (ug/m3) (ug/m3) (ug/m3)

901 5 0.222451 0.200206 0.155716 0.08898

3090 32 0.417505 0.167002

LIMITE REFERENCIAL Fe ((2)Summary of Point of Impingement Standards, Point of 4.0(2)


Impingement Guidelines and Ambient Air Quality Criteria. Standards Development Branch
Ontario Ministry of the Environment. September 2001.)

2.3.7. Resultados del Anlisis de Pluma y Dispersin de Concentracin de


Partculas de Hierro proveniente del Horno de Acera

De acuerdo a los resultados de la pluma de dispersin atmosfrica de las


emisiones emitida por el Horno de Hierro Esponja se concluye lo siguiente:

De las Figuras N24, N25, Mapa N12 y Cuadro N25 se observa que las
concentraciones de partculas emitidas, por la Chimenea se desplazan en
direccin de Oeste a Este (Barlovento Sotavento de la chimenea).
La altura final de la pluma de la chimenea para el Horno de Hierro Esponja
es de 84.04m.
Se observa del Modelo de Dispersin, que a 901m y 3090m equidistantes
de la fuente del Horno de Hierro Esponja, se generan mayores
concentraciones de Partculas de Hierro (Fe), las cuales son de 0.222 g/m3
y 0.417 ug/m3 respectivamente.

Pg. N 72
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

MAPA N 13 Modelo de dispersin de Chimenea Horno de Hierro Esponja Concentracin de Monxido de Carbono (CO)

Pg. N 73
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

2.3.8. Anlisis de Pluma y Dispersin de Concentracin de Monxido de Carbono (CO) en Horno de Hierro Esponja

FIGURA N 26 Anlisis de Pluma y Dispersin de Concentracin de Monxido de Carbono (CO) - Horno de Hierro Esponja

Anlisis de Pluma y Dispersin de Concentracin de Monxido de Carbono CO (ug/m 3 ) - Horno de Hierro Esponja
180m
Viento Octubre 2012 - Marzo 2013
170m

160m

150m

140m

130m PLUMA
120m

115m

1.482 ug/m3
110m

1.572 ug/m3
h= 55 m 107m

1.778 ug/m3
103m
102m

2.028 ug/m3
2.174 ug/m3
100m

98m

2.419 ug/m3
2.814 ug/m3
3.047 ug/m3
95m

92m

3.780 ug/m3
90m
3.426 ug/m3

H= 84.04 m
Lindero de CAASA 4.31 ug/m3

4.122 ug/m3
88m

4.711 ug/m3
5.131 ug/m3
Hs= 29 m 85m

5.779 ug/m3
82m 6.102 ug/m3
5.642 ug/m3
5.429 ug/m3

80m
Carretera

78m
HORNO DE HIERRO ESPONJA
74m

73m

0km 0.25km 0.5 0.57 0.70.75 0.8 0.9 1.0 1.2 1.25 1.35 1.5 1.6 1.75 1.9 2.0 2.2 2.25 2.4 2.5 2.7 2.75 2.9 3.0km

Pg. N 74
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

FIGURA N 27 Concentracin de Monxido de carbono (CO) Vs Distancia


Concentracin ug/m3

Distancia (km)

Cuadro N26 Resultados de Mxima Concentracin de Monxido de Carbono (CO)


Horno de Hierro Esponja

Altura de Mxima Mxima Mxima Mxima


Distancia
terreno Concent. 1Hr Concent. 3Hr Concent. 8Hr Concent. 24Hr
Mxima (m)
(m) (ug/m3) (ug/m3) (ug/m3) (ug/m3)

901 5 6.10289 5.492601 4.272023 2.441156

3090 32 11.454174 4.58167

LIMITE REFERENCIAL CO ((3) D.S. N 003-2008-MINAM Estndares Nacionales de 30000(3)


Calidad Ambiental del Aire)

2.3.9. Resultados del Anlisis de Pluma y Dispersin de Concentracin de


Monxido de Carbono proveniente del Horno de Hierro Esponja

De acuerdo a los resultados de la pluma de dispersin atmosfrica de las


emisiones emitida por el Horno de Hierro Esponja se concluye lo siguiente:

De las Figuras N26, N27, Mapa N13 y Cuadro N26 se observa que las
concentraciones de partculas emitidas, por la Chimenea se desplazan en
direccin de Oeste a Este (Barlovento Sotavento de la chimenea).
La altura final de la pluma de la chimenea para el Horno de Hierro Esponja
es de 84.04m.
Se observa del Modelo de Dispersin, que a 901m y 3090m equidistantes
de la fuente del Horno de Hierro Esponja, se generan mayores
concentraciones de Monxido de Carbono (CO), las cuales son de 6.102
g/m3 y 11.454 ug/m3 respectivamente.

Pg. N 75
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

MAPA N 14 Modelo de dispersin de Chimenea Horno de Hierro Esponja Concentracin de xido de Nitrgeno (NO)

Pg. N 76
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

2.3.10. Anlisis de Pluma y Dispersin de Concentracin de xido de Nitrgeno (NOx) en Horno de Hierro Esponja

FIGURA N 28 Anlisis de Pluma y Dispersin de Concentracin de xido de Nitrgeno (NOx) - Horno de Hierro Esponja

Anlisis de Pluma y Dispersin de Concentracin de Oxido de Nitrogeno NO (ug/m 3 ) - Horno de Hierro Esponja
180m
Viento Octubre 2012 - Marzo 2013
170m

160m

150m

140m

130m PLUMA
120m

115m

1.327 ug/m3
110m

1.407 ug/m3
h= 55 m 107m

1.592 ug/m3
103m
102m

1.816 ug/m3
1.947 ug/m3
100m

98m

2.166 ug/m3
2.519 ug/m3
2.728 ug/m3
95m

92m

3.384 ug/m3
90m
3.068 ug/m3
Lindero de CAASA 3.859 ug/m3

H= 84.04 m

3.691 ug/m3
88m

4.218 ug/m3
4.594 ug/m3
Hs= 29 m 85m
5.175 ug/m3
5.464 ug/m3

82m
5.052 ug/m3
4.861 ug/m3

80m
Carretera

78m
HORNO DE HIERRO ESPONJA
74m

73m

0km 0.25km 0.5 0.57 0.70.75 0.8 0.9 1.0 1.2 1.25 1.35 1.5 1.6 1.75 1.9 2.0 2.2 2.25 2.4 2.5 2.7 2.75 2.9 3.0km

Pg. N 77
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

Concentracin ug/m3 FIGURA N29 Concentracin de xido de Nitrgeno (NOx) Vs Distancia

Distancia (km)

Cuadro N27 Resultados de Mxima Concentracin de xido de Nitrgeno Horno de


Hierro Esponja

Altura de Mxima Mxima Mxima Mxima


Distancia
terreno Concent. 1Hr Concent. 3Hr Concent. 8Hr Concent. 24Hr
Mxima (m)
(m) (ug/m3) (ug/m3) (ug/m3) (ug/m3)

901 5 5.46455 4.918095 3.825185 2.18582

3090 32 10.256124 4.10245

LIMITE REFERENCIAL NO ((4) D.S. N 003-2008-MINAM Estndares Nacionales de 200(4)


Calidad Ambiental del Aire)

2.3.11. Resultados del Anlisis de Pluma y Dispersin de Concentracin de xido


de Nitrgeno proveniente del Horno de Hierro Esponja

De acuerdo a los resultados de la pluma de dispersin atmosfrica de las


emisiones emitida por el Horno de Hierro Esponja se concluye lo siguiente:

De las Figuras N28, N29, Mapa N14 y Cuadro N27 se observa que las
concentraciones de partculas emitidas, por la Chimenea se desplazan en
direccin de Oeste a Este (Barlovento Sotavento de la chimenea).
La altura final de la pluma de la chimenea para el Horno de Hierro Esponja es
de 84.04m.
Se observa del Modelo de Dispersin, que a 901m y 3090m equidistantes de
la fuente del Horno de Hierro Esponja, se generan mayores concentraciones
de xido de Nitrgeno (NO), las cuales son de 5.464 g/m3 y 10.256 ug/m3
respectivamente.

Pg. N 78
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

MAPA N 15 Modelo de dispersin de Chimenea Horno de Hierro Esponja Concentracin de Dixido de Azufre (SO2)

Pg. N 79
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

2.3.12. Anlisis de Pluma y Dispersin de Concentracin de Dixido de Azufre (SO 2) en Horno de Hierro Esponja

FIGURA N 30 Anlisis de Pluma y Dispersin de Concentracin de Dixido de Azufre (SO2)- Horno de Hierro Esponja

Anlisis de Pluma y Dispersin de Concentracin de Dioxido de Azufre SO 2 (ug/m3 ) - Horno de Hierro Esponja
180m
Viento Octubre 2012 - Marzo 2013
170m

160m

150m

140m

130m PLUMA
120m

115m

11.20 ug/m3
110m

11.87 ug/m3
h= 55 m 107m

13.43 ug/m3
103m
102m

15.32 ug/m3
16.42 ug/m3
100m

98m

18.27 ug/m3
21.26 ug/m3
23.02 ug/m3
95m

92m

28.55 ug/m3
90m
25.88 ug/m3
Lindero de CAASA 32.56 ug/m3

H= 84.04 m

31.14 ug/m3
88m

35.58 ug/m3
38.76 ug/m3
Hs= 29 m 85m
43.66 ug/m3
46.10 ug/m3

82m
42.62 ug/m3
41.01 ug/m3

80m
Carretera

78m
HORNO DE HIERRO ESPONJA
74m

73m

0km 0.25km 0.5 0.57 0.70.75 0.8 0.9 1.0 1.2 1.25 1.35 1.5 1.6 1.75 1.9 2.0 2.2 2.25 2.4 2.5 2.7 2.75 2.9 3.0km

Pg. N 80
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

FIGURA N31 Concentracin de Dixido de Azufre (SO2) Vs Distancia


Concentracin ug/m3X10-1

Distancia (km)

Cuadro N28 Resultados de Mxima Concentracin de Dixido de Azufre (SO 2)


Horno de Hierro Esponja

Altura de Mxima Mxima Mxima Mxima


Distancia
terreno Concent. 1Hr Concent. 3Hr Concent. 8Hr Concent. 24Hr
Mxima (m)
(m) (ug/m3) (ug/m3) (ug/m3) (ug/m3)

901 5 46.1 41.49 32.27 18.44

3090 32 86.52 34.61

LIMITE REFERENCIAL SO2 ((5) D.S. N 003-2008-MINAM Estndares Nacionales de 80(5)


Calidad Ambiental del Aire)

2.3.13. Resultados del Anlisis de Pluma y Dispersin de Concentracin de


Dixido de Azufre proveniente del Horno de Hierro Esponja

De acuerdo a los resultados de la pluma de dispersin atmosfrica de las


emisiones emitida por el Horno de Hierro Esponja se concluye lo siguiente:

De las Figuras N30, N31, Mapa N15 y Cuadro N28 se observa que las
concentraciones de partculas emitidas, por la Chimenea se desplazan en
direccin de Oeste a Este (Barlovento Sotavento de la chimenea).
La altura final de la pluma de la chimenea para el Horno de Hierro Esponja
es de 84.04m.
Se observa del Modelo de Dispersin, que a 901m y 3090m equidistantes
de la fuente del Horno de Hierro Esponja, se generan mayores
concentraciones de Dixido de Azufre (SO2), las cuales son de 46.1 g/m3 y
86.52ug/m3 respectivamente.

81
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

2.3.14. Resultados de concentraciones segn tipo de contaminantes proveniente


del Horno de Hierro Esponja

A continuacin se muestra los resultados del modelo gaussiano aplicado,


proveniente del Horno de Hierro Esponja descrito en la seccin anterior, en
donde las concentraciones emitidas estn en funcin de la distancia a la fuente
emisora, con una distancia de hasta 3 km.

Grfico N 5 Concentraciones segn Contaminantes provenientes


del Horno de Hierro Esponja

De la Tabla N1(Datos Promedios), se observa que la tasa de emisin de SO2


(9.533 g/s) es mayor que las tasas de PTS (1.288 g/s), Fe (0.046 g/s), CO (1.262
g/s) y NO (1.13 g/s), dichas cantidades coinciden con los resultados obtenidos en
el modelo gaussiano (ver grfico N5), y cuyas concentraciones de SO2
(46.1ug/m3), es mayor de las concentraciones de PTS (6.229ug/m3), Fe
(0.222ug/m3) , CO(6.103 ug/m3) y NO (5.465ug/m3).

Asimismo se observa del grfico N5 que a 900m de distancia de la fuente se


genera las mximas concentraciones de PTS, Fe, CO, NO, SO2 proveniente del
Horno de Laminacin.

82
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

3. CONCLUSIONES

De acuerdo a los valores y grficos obtenidos en el Modelo de Dispersin, los valores de


Partculas Totales en Suspensin (PTS), Partculas de Hierro (Fe), Monxido de Carbono (CO),
xidos de Nitrgeno (NO), Dixido de Azufre (SO2), alcanzan su mayor concentracin
provenientes de: Horno de Acera a 1640m, Horno de laminacin a 870m y Horno de Hierro
esponja a 900m aproximadamente.

De acuerdo a los resultados entregados por el modelo Screen3, el aporte de las concentraciones
diarias de PTS, Fe, CO, NO, SO2 (contaminante con mayor tasa de emisin) son marginales (de
baja significancia) y cuyas concentraciones no sobrepasarn los lmites mximos establecidos en
las normas vigentes para los contaminantes PTS, Fe, CO, NOx, SO 2.

La modelacin de la dispersin de los contaminantes junto a los procedimientos empleados, han


sido realizados de acuerdo a los protocolos de la Agencia de Proteccin Ambiental de los Estados
Unidos (US EPA) y los resultados obtenidos indican que las emisiones proveniente de los hornos
de Acera, laminacin y Hierro esponja no sobrepasan los lmites mximos establecidos en las
normas vigentes.

83
Informe de Modelacin de Dispersin Atmosfrica de Chimeneas_____________________________CAASA
Octubre 2012 Marzo 2013

4. ANEXOS
ANEXO N 01 : Clculos promedios de emisiones de chimeneas Acera,
Laminacin, Hierro Esponja (Octubre 2012 Marzo 2013)

ANEXO N 02 : Calculo de Velocidad de Vientos a diferentes alturas

ANEXO N 03 : Clculos Altura Efectiva

ANEXO N 04 : Resultados de Modelo Screen View

ANEXO N 05 : Datos Meteorolgicos Octubre 2012 - Marzo 2013

84
INFORME DE MODELACIN DE EMISIONES
ATMOSFRICA

41
HORNO ACERIA 2012 2013
FECHA OCTUBRE NOVIEMBRE DICIEMBRE ENERO FEBRERO MARZO Unid. MINIMO PROMEDIO MAXIMO
FLUJO VOLUMTRICO 632790.34 647110.83 653854.4 631222.12 610497.68 627279.67 Nm3/h 610497.680 633792.507 653854.400
PARTCULAS (PTS) 0.10 0.259 0.196 0.337 0.192 4.062 g/s 0.100 0.858 4.062
HIERRO (Fe) 0.04 0.056 0.004 0.114 0.080 0.068 g/s 0.004 0.060 0.114
MONOXIDO DE CARBONO (CO) 41.97 81.495 36.556 55.747 35.616 15.175 g/s 15.175 44.427 81.495
XIDOS DE NITRGENO (NOX) 3.129 1.231 0.498 1.08 0.465 0.357 g/s 0.357 1.127 3.129
DIXIDO DE AZUFRE (SO2) 0.334 0 0 0 0 0 g/s 0.000 0.056 0.334
VELOCIDAD DE SALIDA DE GASES 18.15 18.31 18.12 18.22 17.71 17.73 m/s 17.710 18.040 18.310
TEMPERATURA DE SALIDA DE LOS GASES 374.8 375.46 372.37 379.57 385.2 367.67 K 367.670 375.845 385.200
TEMPERATURA AMBIENTE 298.33 299.17 303.5 302.3 304.03 308.8 K 298.330 302.688 308.800
ALTURA DE CHIMENEA 16.5 16.5 16.5 16.5 16.5 16.5 m 16.500 16.500 16.500
DIMETRO EQUIVALENTE CHIMENEA 4.2 4.2 4.2 4.2 4.2 4.2 m 4.200 4.200 4.200
TIEMPO DE EMISIN 24 24 24 24 24 24 h/d 24.000 24.000 24.000
FLUJO MASICO 814717.56 833155.2 841837.54 812698.48 786015.77 807622.58 kg/h 786015.770 816007.855 841837.540

HORNO LAMINACION 2012 2013


FECHA OCTUBRE NOVIEMBRE DICIEMBRE ENERO FEBRERO MARZO Unid. MINIMO PROMEDIO MAXIMO
FLUJO VOLUMTRICO 42801.52 23523.03 32588.55 26141.16 26901.23 23900.54 Nm3/h 23523.030 29309.338 42801.520
PARTCULAS (PTS) 0.328 0.035 0.037 0.038 0.007 0.027 g/s 0.007 0.079 0.328
FIERRO (Fe) 0.010 0.008 0.006 0.013 0.005 0.018 g/s 0.005 0.01 0.018
MONOXIDO DE CARBONO (CO) 0.011 0.176 0.004 0.006 0.014 0.006 g/s 0.004 0.036 0.176
XIDOS DE NITRGENO (NOX) 1.778 1.29 1.331 1.208 1.216 0.976 g/s 0.976 1.300 1.778
DIXIDO DE AZUFRE (SO2) 0 0 0 0 0 0 g/s 0.000 0.000 0.000
VELOCIDAD DE SALIDA DE GASES 17.04 9.97 11.01 9.89 9.26 8.74 m/s 8.740 10.985 17.040
TEMPERATURA DE SALIDA DE LOS GASES 651.3 671.5 571.1 605.1 574.27 555.87 K 555.870 604.857 671.500
TEMPERATURA AMBIENTE 293.6 298.4 299.2 297.4 299.4 304.5 K 293.600 298.750 304.500
ALTURA DE CHIMENEA 25 25 25 25 25 25 m 25.000 25.000 25.000
DIMETRO EQUIVALENTE CHIMENEA 1.5 1.5 1.5 1.5 1.5 1.5 m 1.500 1.500 1.500
TIEMPO DE EMISIN 24 24 24 24 24 24 h/d 24.000 24.000 24.000
FLUJO MASICO 56100.57 30831.97 42714.27 34263.59 35259.83 31326.78 kg/h 30831.970 38416.168 56100.570

42
HORNO HIERRO ESPONJA 2012 2013
FECHA OCTUBRE NOVIEMBRE DICIEMBRE ENERO FEBRERO MARZO Unid. MINIMO PROMEDIO MAXIMO
3
FLUJO VOLUMTRICO 63689.55 43757.91 86264.07 69474.31 64076.12 53810.13 Nm /h 43757.910 63512.015 86264.070
PARTCULAS (PTS) 6.881 0.194 0.306 0.06 0.156 0.131 g/s 0.060 1.288 6.881
FIERRO (Fe) 0.173 0.021 0.005 0.016 0.050 0.012 g/s 0.005 0.046 0.173
MONOXIDO DE CARBONO (CO) 1.186 0.743 1.892 1.424 1.155 1.172 g/s 0.743 1.262 1.892
XIDOS DE NITRGENO (NOX) 0.924 0.97 1.493 1.17 1.095 1.13 g/s 0.924 1.130 1.493
DIXIDO DE AZUFRE (SO2) 10.449 6.156 12.018 9.707 9.089 9.781 g/s 6.156 9.533 12.018
VELOCIDAD DE SALIDA DE GASES 14.85 11.07 16.37 16.49 15.62 11.61 m/s 11.070 14.335 16.490
TEMPERATURA DE SALIDA DE LOS GASES 439.1 466.07 442.73 443.37 432.27 408.2 K 408.200 438.623 466.070
TEMPERATURA AMBIENTE 293.6 295.7 301 303.5 302.1 302.4 K 293.600 299.717 303.500
ALTURA DE CHIMENEA 29 29 29 29 29 29 m 29.000 29.000 29.000
DIMETRO EQUIVALENTE CHIMENEA 1.6 1.6 1.6 1.6 1.6 1.6 m 1.600 1.600 1.600
TIEMPO DE EMISIN 24 24 24 24 24 24 h/d 24.000 24.000 24.000
FLUJO MASICO 85753.43 58916.9 116656.76 93939.19 86640.07 72758.99 kg/h 58916.900 85777.557 116656.760

43
INFORME DE MODELACIN DE EMISIONES
ATMOSFRICA

44
Calculo deVelocidad de viento a diferentes alturas

Datos

Z(m)= Altura de estacin metereologica o anemometro ___________________________ 5.00 m

u= Velocidad prom. de viento de estacin meter. A 5 m de altura ___________ 3.5 m/s

Resultados

n= factor n ________________________________________________ 0.245

u(Zo)= Velocidad del viento a 10 m de altura ___________________ 4.1 m/s

u(m/s) Z m n Zo (m) U(Z0) m/s


5.00 3.5
3.5 5.00 0.24 10 4.1
3.5 5.00 0.24 15 4.5
3.5 5.00 0.23 20 4.8
3.5 5.00 0.23 25 5.0
3.5 5.00 0.22 30 5.2
3.5 5.00 0.22 40 5.5

Altura Vs Velocidad de viento

45.00

40.00

35.00

30.00

25.00
Altura (m)

20.00

Altura Vs Velocidad de viento


15.00

10.00

5.00

0.00
3.5 4.1 4.5 4.8 5.0 5.2 5.5

Velocidad (m/s)

45
INFORME DE MODELACIN DE EMISIONES
ATMOSFRICA

46
47
Calculo de Elevacin de Pluma de Chimenea

HORNO DE ACERIA

Datos

Vs = Velocidad de salida de la chimenea ____________________________________________ 18.04 m/s


r= Radio interior de la chimenea ____________________________________________ 2.1 m
u= Velocidad de viento a la altura de chimenea ________________________________________ 5 m/s
P= Presion _____________________________________________________________________ 1013 mbar
Ts = Temperatura del gas de la chimenea ____________________________________________ 375.85 K
Ta = Temperatura atmosfrica o Temp. Ambiente ___________________________________ 302.69 K
Hs = Altura de Chimenea __________________________________________________ 16.5 m
X= Distancia a sotavento de la chimenea /fuente _______________________________ 435 m
g= Aceleracin debido a la gravedad ______________________________________________ 9.806 m/s2
V= Tasa volumetrica del flujo de gas de la chimenea 633792.507 Nm3/h = 176.05 Nm3/s

Resultados

Fluctuaciones de Momento y Flotabilidad


Fb= Fluctuacin de flotabilidad Briggs (flujo ascensional especifico inicial de la columan emitida) 151.850 m4/s3
Fm= Fluctuacin de Momento (elevacin de la pluma debido al impulso de la pluma) 1155.84 m4/s2
xf= Distancia aguas abajo a partir de la cota mxima de la elevacin del penacho ______ 887.39 m
h= Altura de la columna de humo o elevacin de pluma _______________________________ 98.01 m

H= Altura final de la pluma o altura efectiva de chimenea ___________________ 114.5 m

Descripcion: HORNO DE ACERIA


Empresa: Aceros Arequipa Sede N2 Pisco

h = 98.01 m

H= 114.5 m

Hs= 16.5 m

48
49
Calculo de Elevacin de Pluma de Chimenea

HORNO DE LAMINACIN

Datos

Vs = Velocidad de salida de la chimenea


____________________________________________ 10.985 m/s
r= Radio interior de la chimenea ____________________________________________ 0.75 m
u= Velocidad de viento a la altura de chimenea________________________________________ 5 m/s
P= Presion
_____________________________________________________________________ 1013 mbar
Ts = Temperatura del gas de la chimenea
____________________________________________ 604.86 K
Ta = Temperatura atmosfrica o Temp. Ambiente___________________________________ 298.75 K
Hs = Altura de Chimenea __________________________________________________ 25 m
X= Distancia a sotavento de la chimenea /fuente _______________________________ 25 m
g= Aceleracin debido a la gravedad
______________________________________________ 9.806 m/s2
V= Tasa volumetrica del flujo de gas de la chimenea 29309.338 Nm3/h = 8.1415 Nm3/s

Resultados

Fluctuaciones de Momento y Flotabilidad


Fb= Fluctuacin de flotabilidad Briggs (flujo ascensional especifico inicial de la columan emitida) 30.664 m4/s3
Fm= Fluctuacin de Momento (elevacin de la pluma debido al impulso de la pluma) 33.526 m4/s2
xf= Distancia aguas abajo a partir de la cota mxima de la elevacin del penacho ______ 416.24 m
h= Altura de la columna de humo o elevacin de pluma_______________________________ 57.33 m

H= Altura final de la pluma o altura efectiva de chimenea ___________________ 82.3 m

Descripcion: HORNO DE LAMINACIN


Empresa: Aceros Arequipa Sede N2 Pisco

h = 57.33 m

H= 82.3 m

Hs= 25 m

410
411
Calculo de Elevacin de Pluma de Chimenea

HORNO DE HIERRO ESPONJA

Datos

Vs = Velocidad de salida de la chimenea


____________________________________________ 14.335 m/s
r= Radio interior de la chimenea ____________________________________________ 0.8 m
u= Velocidad de viento a la altura de chimenea________________________________________ 5 m/s
P= Presion
_____________________________________________________________________ 1013 mbar
Ts = Temperatura del gas de la chimenea
____________________________________________ 438.62 K
Ta = Temperatura atmosfrica o Temp. Ambiente___________________________________ 299.72 K
Hs = Altura de Chimenea __________________________________________________ 29 m
X= Distancia a sotavento de la chimenea /fuente _______________________________ 29 m
g= Aceleracin debido a la gravedad
______________________________________________ 9.806 m/s2
V= Tasa volumetrica del flujo de gas de la chimenea 63512.015 Nm3/h = 17.642 Nm3/s

Resultados

Fluctuaciones de Momento y Flotabilidad


Fb= Fluctuacin de flotabilidad Briggs (flujo ascensional especifico inicial de la columan emitida) 28.490 m4/s3
Fm= Fluctuacin de Momento (elevacin de la pluma debido al impulso de la pluma) 89.866 m4/s2
xf= Distancia aguas abajo a partir de la cota mxima de la elevacin del penacho ______ 397.54 m
h= Altura de la columna de humo o elevacin de pluma_______________________________ 55.04 m

H= Altura final de la pluma o altura efectiva de chimenea ___________________ 84.04 m

Descripcion: HORNO DE HIERRO ESPONJA


Empresa: Aceros Arequipa Sede N2 Pisco

h = 55.04 m

H= 84.0 m

Hs= 29 m

412
INFORME DE MODELACIN DE EMISIONES
ATMOSFRICA

413
414
PTS
08/10/13
04:02:56
*** SCREEN3 MODEL RUN ***
*** VERSION DATED 96043 ***

PARTICULAS PTS - HORNO DE ACERIA - OCTUBRE 2012 - MARZO 2013

COMPLEX TERRAIN INPUTS:


SOURCE TYPE = POINT
EMISSION RATE (G/S) = 0.858000
STACK HT (M) = 16.5000
STACK DIAMETER (M) = 4.2000
STACK VELOCITY (M/S) = 18.0400
STACK GAS TEMP (K) = 375.8450
AMBIENT AIR TEMP (K) = 302.6880
RECEPTOR HEIGHT (M) = 0.0000
URBAN/RURAL OPTION = RURAL

THE REGULATORY (DEFAULT) MIXING HEIGHT OPTION WAS SELECTED.


THE REGULATORY (DEFAULT) ANEMOMETER HEIGHT OF 10.0 METERS WAS ENTERED.

BUOY. FLUX = 151.852 M**4/S**3; MOM. FLUX = 1155.841 M**4/S**2.

FINAL STABLE PLUME HEIGHT (M) = 114.5


DISTANCE TO FINAL RISE (M) = 153.8

*VALLEY 24-HR CALCS* **SIMPLE TERRAIN 24-HR CALCS**


TERR MAX 24-HR PLUME HT PLUME HT
HT DIST CONC CONC ABOVE STK CONC ABOVE STK U10M USTK
(M) (M) (UG/M**3) (UG/M**3) BASE (M) (UG/M**3) HGT (M) SC (M/S)
----- ------- ---------- ---------- ------ ---------- ------ -- ---- ----
17. 2060. 0.6671 0.5582E-01 114.5 0.6671 45.5 4 15.0 16.2
23. 2580. 0.5823 0.9100E-01 114.5 0.5823 76.4 6 4.0 5.3
34. 3180. 0.5662 0.1725 114.5 0.5662 76.4 6 4.0 5.3
08/10/13
04:02:56
*** SCREEN3 MODEL RUN ***
*** VERSION DATED 96043 ***

PARTICULAS PTS - HORNO DE ACERIA - OCTUBRE 2012 - MARZO 2013


SIMPLE TERRAIN INPUTS:
SOURCE TYPE = POINT
EMISSION RATE (G/S) = 0.858000
STACK HEIGHT (M) = 16.5000
STK INSIDE DIAM (M) = 4.2000
STK EXIT VELOCITY (M/S)= 18.0400
STK GAS EXIT TEMP (K) = 375.8450
AMBIENT AIR TEMP (K) = 302.6880
RECEPTOR HEIGHT (M) = 1.6500
URBAN/RURAL OPTION = RURAL
BUILDING HEIGHT (M) = 0.0000
MIN HORIZ BLDG DIM (M) = 0.0000
MAX HORIZ BLDG DIM (M) = 0.0000

THE REGULATORY (DEFAULT) MIXING HEIGHT OPTION WAS SELECTED.


THE REGULATORY (DEFAULT) ANEMOMETER HEIGHT OF 10.0 METERS WAS ENTERED.

415
BUOY. FLUX = 151.852 M**4/S**3; MOM. FLUX = 1155.841 M**4/S**2.

*** STABILITY CLASS 3 ONLY ***


*** ANEMOMETER HEIGHT WIND SPEED OF 5.00 M/S ONLY ***

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************
*** TERRAIN HEIGHT OF 0. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1. 0.000 3 5.0 5.3 1600.0 166.45 1.96 1.96 NO
100. 0.000 3 5.0 5.3 1600.0 166.45 15.98 12.46 NO
200. 0.3965E-11 3 5.0 5.3 1600.0 166.45 28.45 21.18 NO
300. 0.3587E-05 3 5.0 5.3 1600.0 166.45 40.10 29.08 NO
400. 0.8732E-03 3 5.0 5.3 1600.0 166.45 51.26 36.52 NO
500. 0.1350E-01 3 5.0 5.3 1600.0 166.45 62.08 43.66 NO

ITERATION STOPPED AT 50 - MAX NOT FOUND!!!

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1. M:


788. 0.2772 3 5.0 5.3 1600.0 166.45 92.05 63.19 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 1. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
500. 0.1473E-01 3 5.0 5.3 1600.0 165.45 62.08 43.66 NO
600. 0.6739E-01 3 5.0 5.3 1600.0 165.45 72.64 50.57 NO

ITERATION STOPPED AT 50 - MAX NOT FOUND!!!

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 500. M:


938. 0.4802 3 5.0 5.3 1600.0 165.45 106.38 71.88 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 1. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
633. 0.9660E-01 3 5.0 5.3 1600.0 165.35 76.08 52.81 NO
700. 0.1706 3 5.0 5.3 1600.0 165.35 82.99 57.31 NO
800. 0.3075 3 5.0 5.3 1600.0 165.35 93.16 63.91 NO

ITERATION STOPPED AT 50 - MAX NOT FOUND!!!

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 633. M:


1580. 0.8492 3 5.0 5.3 1600.0 165.35 162.88 102.80 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 6. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH

416
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
863. 0.4751 3 5.0 5.3 1600.0 160.45 99.49 68.00 NO
900. 0.5256 3 5.0 5.3 1600.0 160.45 103.01 70.13 NO
1000. 0.6195 3 5.0 5.3 1600.0 160.45 111.66 74.66 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 863. M:


1753. 0.9286 3 5.0 5.3 1600.0 160.45 176.86 110.74 NO
**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 6. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1070. 0.6810 3 5.0 5.3 1600.0 160.35 117.73 77.89 NO
1100. 0.7048 3 5.0 5.3 1600.0 160.35 120.34 79.28 NO
1200. 0.7751 3 5.0 5.3 1600.0 160.35 129.04 83.99 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1070. M:


1752. 0.9299 3 5.0 5.3 1600.0 160.35 176.77 110.69 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 8. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1280. 0.8540 3 5.0 5.3 1600.0 158.45 135.99 87.79 NO
1300. 0.8638 3 5.0 5.3 1600.0 158.45 137.73 88.75 NO
1400. 0.9041 3 5.0 5.3 1600.0 158.45 146.42 93.56 NO
1500. 0.9313 3 5.0 5.3 1600.0 158.45 155.09 98.41 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1280. M:


1724. 0.9534 3 5.0 5.3 1600.0 158.45 174.36 109.31 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 13. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1500. 1.009 3 5.0 5.3 1600.0 153.45 155.09 98.41 NO
1600. 1.019 3 5.0 5.3 1600.0 153.45 163.75 103.28 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1500. M:


1648. 1.020 3 5.0 5.3 1600.0 153.45 167.81 105.58 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 16. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1640. 1.063 3 5.0 5.3 1600.0 150.45 167.20 105.24 NO
1700. 1.059 3 5.0 5.3 1600.0 150.45 172.38 108.18 NO
1800. 1.048 3 5.0 5.3 1600.0 150.45 180.99 113.10 NO
1900. 1.030 3 5.0 5.3 1600.0 150.45 189.57 118.03 NO
2000. 1.009 3 5.0 5.3 1600.0 150.45 198.13 122.96 NO

417
MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1640. M:
1640. 1.063 3 5.0 5.3 1600.0 150.45 167.20 105.24 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************
*** TERRAIN HEIGHT OF 16. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
2060. 0.9952 3 5.0 5.3 1600.0 150.35 203.26 125.93 NO
2100. 0.9850 3 5.0 5.3 1600.0 150.35 206.67 127.91 NO
2200. 0.9580 3 5.0 5.3 1600.0 150.35 215.17 132.85 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 2060. M:


2060. 0.9952 3 5.0 5.3 1600.0 150.35 203.26 125.93 NO

DWASH= MEANS NO CALC MADE (CONC = 0.0)


DWASH=NO MEANS NO BUILDING DOWNWASH USED
DWASH=HS MEANS HUBER-SNYDER DOWNWASH USED
DWASH=SS MEANS SCHULMAN-SCIRE DOWNWASH USED
DWASH=NA MEANS DOWNWASH NOT APPLICABLE, X<3*LB

********************************************
* SUMMARY OF TERRAIN HEIGHTS ENTERED FOR *
* SIMPLE ELEVATED TERRAIN PROCEDURE *
********************************************

TERRAIN DISTANCE RANGE (M)


HT (M) MINIMUM MAXIMUM
------- -------- --------
0. 1. 500.
1. 500. 633.
1. 633. 863.
6. 863. 1070.
6. 1070. 1280.
8. 1280. 1500.
13. 1500. 1640.
16. 1640. 2060.
16. 2060. 2280.

***************************************
*** SUMMARY OF SCREEN MODEL RESULTS ***
***************************************

CALCULATION MAX CONC DIST TO TERRAIN


PROCEDURE (UG/M**3) MAX (M) HT (M)
-------------- ----------- ------- -------
SIMPLE TERRAIN 1.063 1640. 16.

COMPLEX TERRAIN 0.6671 2060. 17. (24-HR CONC)

***************************************************
** REMEMBER TO INCLUDE BACKGROUND CONCENTRATIONS **
***************************************************

418
Fe
10/03/13
04:23:26
*** SCREEN3 MODEL RUN ***
*** VERSION DATED 96043 ***

HIERRO (Fe) - HORNO DE ACERIA - OCTUBRE 2012 - MARZO 2013

COMPLEX TERRAIN INPUTS:


SOURCE TYPE = POINT
EMISSION RATE (G/S) = 0.600000E-01
STACK HT (M) = 16.5000
STACK DIAMETER (M) = 4.2000
STACK VELOCITY (M/S) = 18.0400
STACK GAS TEMP (K) = 375.8450
AMBIENT AIR TEMP (K) = 302.6880
RECEPTOR HEIGHT (M) = 0.0000
URBAN/RURAL OPTION = RURAL

THE REGULATORY (DEFAULT) MIXING HEIGHT OPTION WAS SELECTED.


THE REGULATORY (DEFAULT) ANEMOMETER HEIGHT OF 10.0 METERS WAS ENTERED.

BUOY. FLUX = 151.852 M**4/S**3; MOM. FLUX = 1155.841 M**4/S**2.

FINAL STABLE PLUME HEIGHT (M) = 114.5


DISTANCE TO FINAL RISE (M) = 153.8

*VALLEY 24-HR CALCS* **SIMPLE TERRAIN 24-HR CALCS**


TERR MAX 24-HR PLUME HT PLUME HT
HT DIST CONC CONC ABOVE STK CONC ABOVE STK U10M USTK
(M) (M) (UG/M**3) (UG/M**3) BASE (M) (UG/M**3) HGT (M) SC (M/S)
----- ------- ---------- ---------- ------ ---------- ------ -- ---- ----
17. 2060. 0.4665E-01 0.3904E-02 114.5 0.4665E-01 45.5 4 15.0 16.2
23. 2580. 0.3652E-01 0.6364E-02 114.5 0.3652E-01 76.4 6 4.0 5.3
34. 3180. 0.3459E-01 0.1206E-01 114.5 0.3459E-01 76.4 6 4.0 5.3
10/03/13
04:23:26
*** SCREEN3 MODEL RUN ***
*** VERSION DATED 96043 ***

HIERRO (Fe) - HORNO DE ACERIA - OCTUBRE 2012 - MARZO 2013

SIMPLE TERRAIN INPUTS:


SOURCE TYPE = POINT
EMISSION RATE (G/S) = 0.600000E-01
STACK HEIGHT (M) = 16.5000
STK INSIDE DIAM (M) = 4.2000
STK EXIT VELOCITY (M/S)= 18.0400
STK GAS EXIT TEMP (K) = 375.8450
AMBIENT AIR TEMP (K) = 302.6880
RECEPTOR HEIGHT (M) = 1.6500
URBAN/RURAL OPTION = RURAL
BUILDING HEIGHT (M) = 0.0000
MIN HORIZ BLDG DIM (M) = 0.0000
MAX HORIZ BLDG DIM (M) = 0.0000

THE REGULATORY (DEFAULT) MIXING HEIGHT OPTION WAS SELECTED.

419
THE REGULATORY (DEFAULT) ANEMOMETER HEIGHT OF 10.0 METERS WAS ENTERED.

BUOY. FLUX = 151.852 M**4/S**3; MOM. FLUX = 1155.841 M**4/S**2.

*** STABILITY CLASS 3 ONLY ***


*** ANEMOMETER HEIGHT WIND SPEED OF 5.00 M/S ONLY ***

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 0. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1. 0.000 3 5.0 5.3 1600.0 166.45 1.96 1.96 NO
100. 0.000 3 5.0 5.3 1600.0 166.45 15.98 12.46 NO
200. 0.2773E-12 3 5.0 5.3 1600.0 166.45 28.45 21.18 NO
300. 0.2508E-06 3 5.0 5.3 1600.0 166.45 40.10 29.08 NO
400. 0.6106E-04 3 5.0 5.3 1600.0 166.45 51.26 36.52 NO
500. 0.9443E-03 3 5.0 5.3 1600.0 166.45 62.08 43.66 NO

ITERATION STOPPED AT 50 - MAX NOT FOUND!!!

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1. M:


788. 0.1938E-01 3 5.0 5.3 1600.0 166.45 92.05 63.19 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 1. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
500. 0.1030E-02 3 5.0 5.3 1600.0 165.45 62.08 43.66 NO
600. 0.4713E-02 3 5.0 5.3 1600.0 165.45 72.64 50.57 NO

ITERATION STOPPED AT 50 - MAX NOT FOUND!!!

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 500. M:


938. 0.3358E-01 3 5.0 5.3 1600.0 165.45 106.38 71.88 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 1. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
633. 0.6755E-02 3 5.0 5.3 1600.0 165.35 76.08 52.81 NO
700. 0.1193E-01 3 5.0 5.3 1600.0 165.35 82.99 57.31 NO
800. 0.2150E-01 3 5.0 5.3 1600.0 165.35 93.16 63.91 NO

ITERATION STOPPED AT 50 - MAX NOT FOUND!!!

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 633. M:


1580. 0.5938E-01 3 5.0 5.3 1600.0 165.35 162.88 102.80 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 6. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

420
DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA
(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
863. 0.3323E-01 3 5.0 5.3 1600.0 160.45 99.49 68.00 NO
900. 0.3676E-01 3 5.0 5.3 1600.0 160.45 103.01 70.13 NO
1000. 0.4332E-01 3 5.0 5.3 1600.0 160.45 111.66 74.66 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 863. M:


1753. 0.6494E-01 3 5.0 5.3 1600.0 160.45 176.86 110.74 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 6. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1070. 0.4762E-01 3 5.0 5.3 1600.0 160.35 117.73 77.89 NO
1100. 0.4928E-01 3 5.0 5.3 1600.0 160.35 120.34 79.28 NO
1200. 0.5420E-01 3 5.0 5.3 1600.0 160.35 129.04 83.99 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1070. M:


1752. 0.6503E-01 3 5.0 5.3 1600.0 160.35 176.77 110.69 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 8. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1280. 0.5972E-01 3 5.0 5.3 1600.0 158.45 135.99 87.79 NO
1300. 0.6040E-01 3 5.0 5.3 1600.0 158.45 137.73 88.75 NO
1400. 0.6322E-01 3 5.0 5.3 1600.0 158.45 146.42 93.56 NO
1500. 0.6513E-01 3 5.0 5.3 1600.0 158.45 155.09 98.41 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1280. M:


1724. 0.6667E-01 3 5.0 5.3 1600.0 158.45 174.36 109.31 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 13. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1500. 0.7059E-01 3 5.0 5.3 1600.0 153.45 155.09 98.41 NO
1600. 0.7125E-01 3 5.0 5.3 1600.0 153.45 163.75 103.28 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1500. M:


1648. 0.7133E-01 3 5.0 5.3 1600.0 153.45 167.81 105.58 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 16. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1640. 0.7432E-01 3 5.0 5.3 1600.0 150.45 167.20 105.24 NO

421
1700. 0.7408E-01 3 5.0 5.3 1600.0 150.45 172.38 108.18 NO
1800. 0.7327E-01 3 5.0 5.3 1600.0 150.45 180.99 113.10 NO
1900. 0.7206E-01 3 5.0 5.3 1600.0 150.45 189.57 118.03 NO
2000. 0.7055E-01 3 5.0 5.3 1600.0 150.45 198.13 122.96 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1640. M:


1640. 0.7432E-01 3 5.0 5.3 1600.0 150.45 167.20 105.24 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 16. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
2060. 0.6960E-01 3 5.0 5.3 1600.0 150.35 203.26 125.93 NO
2100. 0.6888E-01 3 5.0 5.3 1600.0 150.35 206.67 127.91 NO
2200. 0.6699E-01 3 5.0 5.3 1600.0 150.35 215.17 132.85 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 2060. M:


2060. 0.6960E-01 3 5.0 5.3 1600.0 150.35 203.26 125.93 NO

DWASH= MEANS NO CALC MADE (CONC = 0.0)


DWASH=NO MEANS NO BUILDING DOWNWASH USED
DWASH=HS MEANS HUBER-SNYDER DOWNWASH USED
DWASH=SS MEANS SCHULMAN-SCIRE DOWNWASH USED
DWASH=NA MEANS DOWNWASH NOT APPLICABLE, X<3*LB

********************************************
* SUMMARY OF TERRAIN HEIGHTS ENTERED FOR *
* SIMPLE ELEVATED TERRAIN PROCEDURE *
********************************************

TERRAIN DISTANCE RANGE (M)


HT (M) MINIMUM MAXIMUM
------- -------- --------
0. 1. 500.
1. 500. 633.
1. 633. 863.
6. 863. 1070.
6. 1070. 1280.
8. 1280. 1500.
13. 1500. 1640.
16. 1640. 2060.
16. 2060. 2280.

***************************************
*** SUMMARY OF SCREEN MODEL RESULTS ***
***************************************

CALCULATION MAX CONC DIST TO TERRAIN


PROCEDURE (UG/M**3) MAX (M) HT (M)
-------------- ----------- ------- -------
SIMPLE TERRAIN 0.7432E-01 1640. 16.

COMPLEX TERRAIN 0.4665E-01 2060. 17. (24-HR CONC)

***************************************************
** REMEMBER TO INCLUDE BACKGROUND CONCENTRATIONS **
***************************************************

422
CO
08/12/13
09:15:34
*** SCREEN3 MODEL RUN ***
*** VERSION DATED 13043 ***

MONOXIDO DE CARBONO (CO) - HORNO DE ACERIA - OCTUBRE 2012 - MARZO 2013

COMPLEX TERRAIN INPUTS:


SOURCE TYPE = POINT
EMISSION RATE (G/S) = 44.4270
STACK HT (M) = 16.5000
STACK DIAMETER (M) = 4.2000
STACK VELOCITY (M/S) = 18.0400
STACK GAS TEMP (K) = 375.8450
AMBIENT AIR TEMP (K) = 302.6880
RECEPTOR HEIGHT (M) = 0.0000
URBAN/RURAL OPTION = RURAL

THE REGULATORY (DEFAULT) MIXING HEIGHT OPTION WAS SELECTED.


THE REGULATORY (DEFAULT) ANEMOMETER HEIGHT OF 10.0 METERS WAS ENTERED.

BUOY. FLUX = 151.852 M**4/S**3; MOM. FLUX = 1155.841 M**4/S**2.

FINAL STABLE PLUME HEIGHT (M) = 114.5


DISTANCE TO FINAL RISE (M) = 153.8

*VALLEY 24-HR CALCS* **SIMPLE TERRAIN 24-HR CALCS**


TERR MAX 24-HR PLUME HT PLUME HT
HT DIST CONC CONC ABOVE STK CONC ABOVE STK U10M USTK
(M) (M) (UG/M**3) (UG/M**3) BASE (M) (UG/M**3) HGT (M) SC (M/S)
----- ------- ---------- ---------- ------ ---------- ------ -- ---- ----
17. 2060. 34.54 2.890 114.5 34.54 45.5 4 15.0 16.2
23. 2580. 27.04 4.712 114.5 27.04 76.4 6 4.0 5.3
34. 3180. 29.32 8.932 114.5 29.32 76.4 6 4.0 5.3
08/12/13
09:15:34
*** SCREEN3 MODEL RUN ***
*** VERSION DATED 13043 ***

MONOXIDO DE CARBONO (CO) - HORNO DE ACERIA - OCTUBRE 2012 - MARZO 2013

SIMPLE TERRAIN INPUTS:


SOURCE TYPE = POINT
EMISSION RATE (G/S) = 44.4270
STACK HEIGHT (M) = 16.5000
STK INSIDE DIAM (M) = 4.2000
STK EXIT VELOCITY (M/S)= 18.0400
STK GAS EXIT TEMP (K) = 375.8450
AMBIENT AIR TEMP (K) = 302.6880
RECEPTOR HEIGHT (M) = 0.0000
URBAN/RURAL OPTION = RURAL
BUILDING HEIGHT (M) = 0.0000
MIN HORIZ BLDG DIM (M) = 0.0000
MAX HORIZ BLDG DIM (M) = 0.0000

THE REGULATORY (DEFAULT) MIXING HEIGHT OPTION WAS SELECTED.


THE REGULATORY (DEFAULT) ANEMOMETER HEIGHT OF 10.0 METERS WAS ENTERED.

423
BUOY. FLUX = 151.852 M**4/S**3; MOM. FLUX = 1155.841 M**4/S**2.

*** STABILITY CLASS 3 ONLY ***


*** ANEMOMETER HEIGHT WIND SPEED OF 5.00 M/S ONLY ***

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 0. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1. 0.000 3 5.0 5.3 1600.0 166.45 1.96 1.96 NO
100. 0.000 3 5.0 5.3 1600.0 166.45 15.98 12.46 NO
200. 0.1726E-09 3 5.0 5.3 1600.0 166.45 28.45 21.18 NO
300. 0.1766E-03 3 5.0 5.3 1600.0 166.45 40.10 29.08 NO
400. 0.4432E-01 3 5.0 5.3 1600.0 166.45 51.26 36.52 NO
500. 0.6925 3 5.0 5.3 1600.0 166.45 62.08 43.66 NO

ITERATION STOPPED AT 50 - MAX NOT FOUND!!!

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1. M:


788. 14.32 3 5.0 5.3 1600.0 166.45 92.05 63.19 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 1. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
500. 0.7555 3 5.0 5.3 1600.0 165.45 62.08 43.66 NO
600. 3.472 3 5.0 5.3 1600.0 165.45 72.64 50.57 NO

ITERATION STOPPED AT 50 - MAX NOT FOUND!!!

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 500. M:


938. 24.84 3 5.0 5.3 1600.0 165.45 106.38 71.88 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 1. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
633. 5.010 3 5.0 5.3 1600.0 165.25 76.08 52.81 NO
700. 8.853 3 5.0 5.3 1600.0 165.25 82.99 57.31 NO
800. 15.96 3 5.0 5.3 1600.0 165.25 93.16 63.91 NO

ITERATION STOPPED AT 50 - MAX NOT FOUND!!!

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 633. M:


1580. 44.03 3 5.0 5.3 1600.0 165.25 162.88 102.80 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 6. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

424
DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA
(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
863. 24.57 3 5.0 5.3 1600.0 160.45 99.49 68.00 NO
900. 27.19 3 5.0 5.3 1600.0 160.45 103.01 70.13 NO
1000. 32.05 3 5.0 5.3 1600.0 160.45 111.66 74.66 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 863. M:


1754. 48.08 3 5.0 5.3 1600.0 160.45 176.95 110.79 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 6. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1070. 35.24 3 5.0 5.3 1600.0 160.35 117.73 77.89 NO
1100. 36.47 3 5.0 5.3 1600.0 160.35 120.34 79.28 NO
1200. 40.11 3 5.0 5.3 1600.0 160.35 129.04 83.99 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1070. M:


1752. 48.14 3 5.0 5.3 1600.0 160.35 176.77 110.69 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 8. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1280. 44.20 3 5.0 5.3 1600.0 158.45 135.99 87.79 NO
1300. 44.71 3 5.0 5.3 1600.0 158.45 137.73 88.75 NO
1400. 46.80 3 5.0 5.3 1600.0 158.45 146.42 93.56 NO
1500. 48.21 3 5.0 5.3 1600.0 158.45 155.09 98.41 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1280. M:


1724. 49.36 3 5.0 5.3 1600.0 158.45 174.36 109.31 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 13. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1500. 52.26 3 5.0 5.3 1600.0 153.45 155.09 98.41 NO
1600. 52.75 3 5.0 5.3 1600.0 153.45 163.75 103.28 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1500. M:


1649. 52.81 3 5.0 5.3 1600.0 153.45 167.89 105.63 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 16. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1640. 55.02 3 5.0 5.3 1600.0 150.45 167.20 105.24 NO
1700. 54.85 3 5.0 5.3 1600.0 150.45 172.38 108.18 NO

425
1800. 54.25 3 5.0 5.3 1600.0 150.45 180.99 113.10 NO
1900. 53.35 3 5.0 5.3 1600.0 150.45 189.57 118.03 NO
2000. 52.23 3 5.0 5.3 1600.0 150.45 198.13 122.96 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1640. M:


1640. 55.02 3 5.0 5.3 1600.0 150.45 167.20 105.24 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 16. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
2060. 51.53 3 5.0 5.3 1600.0 150.35 203.26 125.93 NO
2100. 51.00 3 5.0 5.3 1600.0 150.35 206.67 127.91 NO
2200. 49.60 3 5.0 5.3 1600.0 150.35 215.17 132.85 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 2060. M:


2060. 51.53 3 5.0 5.3 1600.0 150.35 203.26 125.93 NO

DWASH= MEANS NO CALC MADE (CONC = 0.0)


DWASH=NO MEANS NO BUILDING DOWNWASH USED
DWASH=HS MEANS HUBER-SNYDER DOWNWASH USED
DWASH=SS MEANS SCHULMAN-SCIRE DOWNWASH USED
DWASH=NA MEANS DOWNWASH NOT APPLICABLE, X<3*LB

********************************************
* SUMMARY OF TERRAIN HEIGHTS ENTERED FOR *
* SIMPLE ELEVATED TERRAIN PROCEDURE *
********************************************

TERRAIN DISTANCE RANGE (M)


HT (M) MINIMUM MAXIMUM
------- -------- --------
0.0 1. 500.
1.0 500. 633.
1.2 633. 863.
6.0 863. 1070.
6.1 1070. 1280.
8.0 1280. 1500.
13.0 1500. 1640.
16.0 1640. 2060.
16.1 2060. 2280.

***************************************
*** SUMMARY OF SCREEN MODEL RESULTS ***
***************************************

CALCULATION MAX CONC DIST TO TERRAIN


PROCEDURE (UG/M**3) MAX (M) HT (M)
-------------- ----------- --------- -------
SIMPLE TERRAIN 55.02 1640. 16.

COMPLEX TERRAIN 34.54 2060. 17. (24-HR CONC)

426
NOX
08/12/13
09:48:26
*** SCREEN3 MODEL RUN ***
*** VERSION DATED 96043 ***

NO - HORNO DE ACERIA - OCTUBRE 2012 - MARZO 2013

COMPLEX TERRAIN INPUTS:


SOURCE TYPE = POINT
EMISSION RATE (G/S) = 1.12700
STACK HT (M) = 16.5000
STACK DIAMETER (M) = 4.2000
STACK VELOCITY (M/S) = 18.0400
STACK GAS TEMP (K) = 375.8450
AMBIENT AIR TEMP (K) = 302.6880
RECEPTOR HEIGHT (M) = 0.0000
URBAN/RURAL OPTION = RURAL

THE REGULATORY (DEFAULT) MIXING HEIGHT OPTION WAS SELECTED.


THE REGULATORY (DEFAULT) ANEMOMETER HEIGHT OF 10.0 METERS WAS ENTERED.

BUOY. FLUX = 151.852 M**4/S**3; MOM. FLUX = 1155.841 M**4/S**2.

FINAL STABLE PLUME HEIGHT (M) = 114.5


DISTANCE TO FINAL RISE (M) = 153.8

*VALLEY 24-HR CALCS* **SIMPLE TERRAIN 24-HR CALCS**


TERR MAX 24-HR PLUME HT PLUME HT
HT DIST CONC CONC ABOVE STK CONC ABOVE STK U10M USTK
(M) (M) (UG/M**3) (UG/M**3) BASE (M) (UG/M**3) HGT (M) SC (M/S)
----- ------- ---------- ---------- ------ ---------- ------ -- ---- ----
17. 2060. 0.8763 0.7332E-01 114.5 0.8763 45.5 4 15.0 16.2
23. 2580. 0.6860 0.1195 114.5 0.6860 76.4 6 4.0 5.3
34. 3180. 0.6437 0.2266 114.5 0.6437 76.4 6 4.0 5.3
08/12/13
09:48:26
*** SCREEN3 MODEL RUN ***
*** VERSION DATED 96043 ***

NO - HORNO DE ACERIA - OCTUBRE 2012 - MARZO 2013

SIMPLE TERRAIN INPUTS:


SOURCE TYPE = POINT
EMISSION RATE (G/S) = 1.12700
STACK HEIGHT (M) = 16.5000
STK INSIDE DIAM (M) = 4.2000
STK EXIT VELOCITY (M/S)= 18.0400
STK GAS EXIT TEMP (K) = 375.8450
AMBIENT AIR TEMP (K) = 302.6880
RECEPTOR HEIGHT (M) = 1.6500
URBAN/RURAL OPTION = RURAL
BUILDING HEIGHT (M) = 0.0000
MIN HORIZ BLDG DIM (M) = 0.0000
MAX HORIZ BLDG DIM (M) = 0.0000

THE REGULATORY (DEFAULT) MIXING HEIGHT OPTION WAS SELECTED.


THE REGULATORY (DEFAULT) ANEMOMETER HEIGHT OF 10.0 METERS WAS ENTERED.

427
BUOY. FLUX = 151.852 M**4/S**3; MOM. FLUX = 1155.841 M**4/S**2.

*** STABILITY CLASS 3 ONLY ***


*** ANEMOMETER HEIGHT WIND SPEED OF 5.00 M/S ONLY ***

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 0. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1. 0.000 3 5.0 5.3 1600.0 166.45 1.96 1.96 NO
100. 0.000 3 5.0 5.3 1600.0 166.45 15.98 12.46 NO
200. 0.5209E-11 3 5.0 5.3 1600.0 166.45 28.45 21.18 NO
300. 0.4712E-05 3 5.0 5.3 1600.0 166.45 40.10 29.08 NO
400. 0.1147E-02 3 5.0 5.3 1600.0 166.45 51.26 36.52 NO
500. 0.1774E-01 3 5.0 5.3 1600.0 166.45 62.08 43.66 NO

ITERATION STOPPED AT 50 - MAX NOT FOUND!!!

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1. M:


788. 0.3641 3 5.0 5.3 1600.0 166.45 92.05 63.19 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 1. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
500. 0.1935E-01 3 5.0 5.3 1600.0 165.45 62.08 43.66 NO
600. 0.8852E-01 3 5.0 5.3 1600.0 165.45 72.64 50.57 NO

ITERATION STOPPED AT 50 - MAX NOT FOUND!!!

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 500. M:


938. 0.6307 3 5.0 5.3 1600.0 165.45 106.38 71.88 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 1. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
633. 0.1269 3 5.0 5.3 1600.0 165.35 76.08 52.81 NO
700. 0.2241 3 5.0 5.3 1600.0 165.35 82.99 57.31 NO
800. 0.4039 3 5.0 5.3 1600.0 165.35 93.16 63.91 NO

ITERATION STOPPED AT 50 - MAX NOT FOUND!!!

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 633. M:


1580. 1.115 3 5.0 5.3 1600.0 165.35 162.88 102.80 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 6. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA

428
(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
863. 0.6241 3 5.0 5.3 1600.0 160.45 99.49 68.00 NO
900. 0.6904 3 5.0 5.3 1600.0 160.45 103.01 70.13 NO
1000. 0.8137 3 5.0 5.3 1600.0 160.45 111.66 74.66 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 863. M:


1753. 1.220 3 5.0 5.3 1600.0 160.45 176.86 110.74 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 6. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1070. 0.8945 3 5.0 5.3 1600.0 160.35 117.73 77.89 NO
1100. 0.9257 3 5.0 5.3 1600.0 160.35 120.34 79.28 NO
1200. 1.018 3 5.0 5.3 1600.0 160.35 129.04 83.99 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1070. M:


1752. 1.221 3 5.0 5.3 1600.0 160.35 176.77 110.69 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 8. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1280. 1.122 3 5.0 5.3 1600.0 158.45 135.99 87.79 NO
1300. 1.135 3 5.0 5.3 1600.0 158.45 137.73 88.75 NO
1400. 1.188 3 5.0 5.3 1600.0 158.45 146.42 93.56 NO
1500. 1.223 3 5.0 5.3 1600.0 158.45 155.09 98.41 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1280. M:


1724. 1.252 3 5.0 5.3 1600.0 158.45 174.36 109.31 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 13. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1500. 1.326 3 5.0 5.3 1600.0 153.45 155.09 98.41 NO
1600. 1.338 3 5.0 5.3 1600.0 153.45 163.75 103.28 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1500. M:


1648. 1.340 3 5.0 5.3 1600.0 153.45 167.81 105.58 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 16. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1640. 1.396 3 5.0 5.3 1600.0 150.45 167.20 105.24 NO
1700. 1.391 3 5.0 5.3 1600.0 150.45 172.38 108.18 NO
1800. 1.376 3 5.0 5.3 1600.0 150.45 180.99 113.10 NO

429
1900. 1.354 3 5.0 5.3 1600.0 150.45 189.57 118.03 NO
2000. 1.325 3 5.0 5.3 1600.0 150.45 198.13 122.96 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1640. M:


1640. 1.396 3 5.0 5.3 1600.0 150.45 167.20 105.24 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 16. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
2060. 1.307 3 5.0 5.3 1600.0 150.35 203.26 125.93 NO
2100. 1.294 3 5.0 5.3 1600.0 150.35 206.67 127.91 NO
2200. 1.258 3 5.0 5.3 1600.0 150.35 215.17 132.85 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 2060. M:


2060. 1.307 3 5.0 5.3 1600.0 150.35 203.26 125.93 NO

DWASH= MEANS NO CALC MADE (CONC = 0.0)


DWASH=NO MEANS NO BUILDING DOWNWASH USED
DWASH=HS MEANS HUBER-SNYDER DOWNWASH USED
DWASH=SS MEANS SCHULMAN-SCIRE DOWNWASH USED
DWASH=NA MEANS DOWNWASH NOT APPLICABLE, X<3*LB

********************************************
* SUMMARY OF TERRAIN HEIGHTS ENTERED FOR *
* SIMPLE ELEVATED TERRAIN PROCEDURE *
********************************************

TERRAIN DISTANCE RANGE (M)


HT (M) MINIMUM MAXIMUM
------- -------- --------
0. 1. 500.
1. 500. 633.
1. 633. 863.
6. 863. 1070.
6. 1070. 1280.
8. 1280. 1500.
13. 1500. 1640.
16. 1640. 2060.
16. 2060. 2280.

***************************************
*** SUMMARY OF SCREEN MODEL RESULTS ***
***************************************

CALCULATION MAX CONC DIST TO TERRAIN


PROCEDURE (UG/M**3) MAX (M) HT (M)
-------------- ----------- ------- -------
SIMPLE TERRAIN 1.396 1640. 16.

COMPLEX TERRAIN 0.8763 2060. 17. (24-HR CONC)

***************************************************
** REMEMBER TO INCLUDE BACKGROUND CONCENTRATIONS **
***************************************************

430
SO2
08/12/13
10:11:50
*** SCREEN3 MODEL RUN ***
*** VERSION DATED 13043 ***

SO2 - HORNO DE ACERIA - OCTUBRE 2012 - MARZO 2013

COMPLEX TERRAIN INPUTS:


SOURCE TYPE = POINT
EMISSION RATE (G/S) = 0.560000E-01
STACK HT (M) = 16.5000
STACK DIAMETER (M) = 4.2000
STACK VELOCITY (M/S) = 18.0400
STACK GAS TEMP (K) = 375.8450
AMBIENT AIR TEMP (K) = 302.6880
RECEPTOR HEIGHT (M) = 0.0000
URBAN/RURAL OPTION = RURAL

THE REGULATORY (DEFAULT) MIXING HEIGHT OPTION WAS SELECTED.


THE REGULATORY (DEFAULT) ANEMOMETER HEIGHT OF 10.0 METERS WAS ENTERED.

BUOY. FLUX = 151.852 M**4/S**3; MOM. FLUX = 1155.841 M**4/S**2.

FINAL STABLE PLUME HEIGHT (M) = 114.5


DISTANCE TO FINAL RISE (M) = 153.8

*VALLEY 24-HR CALCS* **SIMPLE TERRAIN 24-HR CALCS**


TERR MAX 24-HR PLUME HT PLUME HT
HT DIST CONC CONC ABOVE STK CONC ABOVE STK U10M USTK
(M) (M) (UG/M**3) (UG/M**3) BASE (M) (UG/M**3) HGT (M) SC (M/S)
----- ------- ---------- ---------- ------ ---------- ------ -- ---- ----
17. 2060. 0.4354E-01 0.3643E-02 114.5 0.4354E-01 45.5 4 15.0 16.2
23. 2580. 0.3409E-01 0.5939E-02 114.5 0.3409E-01 76.4 6 4.0 5.3
34. 3180. 0.3295E-01 0.1126E-01 114.5 0.3295E-01 76.4 6 4.0 5.3
08/12/13
10:11:50
*** SCREEN3 MODEL RUN ***
*** VERSION DATED 13043 ***

SO2 - HORNO DE ACERIA - OCTUBRE 2012 - MARZO 2013

SIMPLE TERRAIN INPUTS:


SOURCE TYPE = POINT
EMISSION RATE (G/S) = 0.560000E-01
STACK HEIGHT (M) = 16.5000
STK INSIDE DIAM (M) = 4.2000
STK EXIT VELOCITY (M/S)= 18.0400
STK GAS EXIT TEMP (K) = 375.8450
AMBIENT AIR TEMP (K) = 302.6880
RECEPTOR HEIGHT (M) = 0.0000
URBAN/RURAL OPTION = RURAL
BUILDING HEIGHT (M) = 0.0000
MIN HORIZ BLDG DIM (M) = 0.0000
MAX HORIZ BLDG DIM (M) = 0.0000

THE REGULATORY (DEFAULT) MIXING HEIGHT OPTION WAS SELECTED.


THE REGULATORY (DEFAULT) ANEMOMETER HEIGHT OF 10.0 METERS WAS ENTERED.

431
BUOY. FLUX = 151.852 M**4/S**3; MOM. FLUX = 1155.841 M**4/S**2.

*** STABILITY CLASS 3 ONLY ***


*** ANEMOMETER HEIGHT WIND SPEED OF 5.00 M/S ONLY ***

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 0. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1. 0.000 3 5.0 5.3 1600.0 166.45 1.96 1.96 NO
100. 0.000 3 5.0 5.3 1600.0 166.45 15.98 12.46 NO
200. 0.2175E-12 3 5.0 5.3 1600.0 166.45 28.45 21.18 NO
300. 0.2227E-06 3 5.0 5.3 1600.0 166.45 40.10 29.08 NO
400. 0.5586E-04 3 5.0 5.3 1600.0 166.45 51.26 36.52 NO
500. 0.8729E-03 3 5.0 5.3 1600.0 166.45 62.08 43.66 NO

ITERATION STOPPED AT 50 - MAX NOT FOUND!!!

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1. M:


788. 0.1805E-01 3 5.0 5.3 1600.0 166.45 92.05 63.19 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 1. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
500. 0.9523E-03 3 5.0 5.3 1600.0 165.45 62.08 43.66 NO
600. 0.4376E-02 3 5.0 5.3 1600.0 165.45 72.64 50.57 NO

ITERATION STOPPED AT 50 - MAX NOT FOUND!!!

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 500. M:


938. 0.3131E-01 3 5.0 5.3 1600.0 165.45 106.38 71.88 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 1. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
633. 0.6315E-02 3 5.0 5.3 1600.0 165.25 76.08 52.81 NO
700. 0.1116E-01 3 5.0 5.3 1600.0 165.25 82.99 57.31 NO
800. 0.2011E-01 3 5.0 5.3 1600.0 165.25 93.16 63.91 NO

ITERATION STOPPED AT 50 - MAX NOT FOUND!!!

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 633. M:


1580. 0.5550E-01 3 5.0 5.3 1600.0 165.25 162.88 102.80 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 6. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH

432
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
863. 0.3097E-01 3 5.0 5.3 1600.0 160.45 99.49 68.00 NO
900. 0.3427E-01 3 5.0 5.3 1600.0 160.45 103.01 70.13 NO
1000. 0.4040E-01 3 5.0 5.3 1600.0 160.45 111.66 74.66 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 863. M:


1754. 0.6060E-01 3 5.0 5.3 1600.0 160.45 176.95 110.79 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 6. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1070. 0.4442E-01 3 5.0 5.3 1600.0 160.35 117.73 77.89 NO
1100. 0.4597E-01 3 5.0 5.3 1600.0 160.35 120.34 79.28 NO
1200. 0.5056E-01 3 5.0 5.3 1600.0 160.35 129.04 83.99 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1070. M:


1752. 0.6068E-01 3 5.0 5.3 1600.0 160.35 176.77 110.69 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 8. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1280. 0.5572E-01 3 5.0 5.3 1600.0 158.45 135.99 87.79 NO
1300. 0.5635E-01 3 5.0 5.3 1600.0 158.45 137.73 88.75 NO
1400. 0.5899E-01 3 5.0 5.3 1600.0 158.45 146.42 93.56 NO
1500. 0.6077E-01 3 5.0 5.3 1600.0 158.45 155.09 98.41 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1280. M:


1724. 0.6222E-01 3 5.0 5.3 1600.0 158.45 174.36 109.31 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 13. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1500. 0.6587E-01 3 5.0 5.3 1600.0 153.45 155.09 98.41 NO
1600. 0.6649E-01 3 5.0 5.3 1600.0 153.45 163.75 103.28 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1500. M:


1649. 0.6656E-01 3 5.0 5.3 1600.0 153.45 167.89 105.63 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 16. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1640. 0.6936E-01 3 5.0 5.3 1600.0 150.45 167.20 105.24 NO
1700. 0.6913E-01 3 5.0 5.3 1600.0 150.45 172.38 108.18 NO
1800. 0.6838E-01 3 5.0 5.3 1600.0 150.45 180.99 113.10 NO
1900. 0.6725E-01 3 5.0 5.3 1600.0 150.45 189.57 118.03 NO

433
2000. 0.6584E-01 3 5.0 5.3 1600.0 150.45 198.13 122.96 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1640. M:


1640. 0.6936E-01 3 5.0 5.3 1600.0 150.45 167.20 105.24 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 16. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
2060. 0.6495E-01 3 5.0 5.3 1600.0 150.35 203.26 125.93 NO
2100. 0.6428E-01 3 5.0 5.3 1600.0 150.35 206.67 127.91 NO
2200. 0.6252E-01 3 5.0 5.3 1600.0 150.35 215.17 132.85 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 2060. M:


2060. 0.6495E-01 3 5.0 5.3 1600.0 150.35 203.26 125.93 NO

DWASH= MEANS NO CALC MADE (CONC = 0.0)


DWASH=NO MEANS NO BUILDING DOWNWASH USED
DWASH=HS MEANS HUBER-SNYDER DOWNWASH USED
DWASH=SS MEANS SCHULMAN-SCIRE DOWNWASH USED
DWASH=NA MEANS DOWNWASH NOT APPLICABLE, X<3*LB

********************************************
* SUMMARY OF TERRAIN HEIGHTS ENTERED FOR *
* SIMPLE ELEVATED TERRAIN PROCEDURE *
********************************************

TERRAIN DISTANCE RANGE (M)


HT (M) MINIMUM MAXIMUM
------- -------- --------
0.0 1. 500.
1.0 500. 633.
1.2 633. 863.
6.0 863. 1070.
6.1 1070. 1280.
8.0 1280. 1500.
13.0 1500. 1640.
16.0 1640. 2060.
16.1 2060. 2280.

***************************************
*** SUMMARY OF SCREEN MODEL RESULTS ***
***************************************

CALCULATION MAX CONC DIST TO TERRAIN


PROCEDURE (UG/M**3) MAX (M) HT (M)
-------------- ----------- --------- -------
SIMPLE TERRAIN 0.6936E-01 1640. 16.

COMPLEX TERRAIN 0.4354E-01 2060. 17. (24-HR CONC)

434
435
PTS
08/12/13
11:21:29
*** SCREEN3 MODEL RUN ***
*** VERSION DATED 13043 ***

PTS - HORNO DE LAMINACION - OCTUBRE 2012 - MARZO 2013

COMPLEX TERRAIN INPUTS:


SOURCE TYPE = POINT
EMISSION RATE (G/S) = 0.790000E-01
STACK HT (M) = 25.0000
STACK DIAMETER (M) = 1.5000
STACK VELOCITY (M/S) = 10.9850
STACK GAS TEMP (K) = 604.8570
AMBIENT AIR TEMP (K) = 298.7500
RECEPTOR HEIGHT (M) = 0.0000
URBAN/RURAL OPTION = RURAL

THE REGULATORY (DEFAULT) MIXING HEIGHT OPTION WAS SELECTED.


THE REGULATORY (DEFAULT) ANEMOMETER HEIGHT OF 10.0 METERS WAS ENTERED.

BUOY. FLUX = 30.665 M**4/S**3; MOM. FLUX = 33.526 M**4/S**2.

FINAL STABLE PLUME HEIGHT (M) = 82.3


DISTANCE TO FINAL RISE (M) = 152.8

*VALLEY 24-HR CALCS* **SIMPLE TERRAIN 24-HR CALCS**


TERR MAX 24-HR PLUME HT PLUME HT
HT DIST CONC CONC ABOVE STK CONC ABOVE STK U10M USTK
(M) (M) (UG/M**3) (UG/M**3) BASE (M) (UG/M**3) HGT (M) SC (M/S)
----- ------- ---------- ---------- ------ ---------- ------ -- ---- ----
25. 2800. 0.2626 0.3302E-01 82.3 0.2626 65.7 6 1.0 1.7
08/12/13
11:21:29
*** SCREEN3 MODEL RUN ***
*** VERSION DATED 13043 ***

PTS - HORNO DE LAMINACION - OCTUBRE 2012 - MARZO 2013

SIMPLE TERRAIN INPUTS:


SOURCE TYPE = POINT
EMISSION RATE (G/S) = 0.790000E-01
STACK HEIGHT (M) = 25.0000
STK INSIDE DIAM (M) = 1.5000
STK EXIT VELOCITY (M/S)= 10.9850
STK GAS EXIT TEMP (K) = 604.8570
AMBIENT AIR TEMP (K) = 298.7500
RECEPTOR HEIGHT (M) = 1.6500
URBAN/RURAL OPTION = RURAL
BUILDING HEIGHT (M) = 0.0000
MIN HORIZ BLDG DIM (M) = 0.0000
MAX HORIZ BLDG DIM (M) = 0.0000

THE REGULATORY (DEFAULT) MIXING HEIGHT OPTION WAS SELECTED.


THE REGULATORY (DEFAULT) ANEMOMETER HEIGHT OF 10.0 METERS WAS ENTERED.

BUOY. FLUX = 30.665 M**4/S**3; MOM. FLUX = 33.526 M**4/S**2.

*** STABILITY CLASS 3 ONLY ***


*** ANEMOMETER HEIGHT WIND SPEED OF 5.00 M/S ONLY ***

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

436
*** TERRAIN HEIGHT OF 0. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1. 0.000 3 5.0 5.5 1600.0 75.95 0.51 0.50 NO
100. 0.3196E-12 3 5.0 5.5 1600.0 75.95 13.67 9.33 NO
200. 0.3551E-03 3 5.0 5.5 1600.0 75.95 25.25 16.63 NO
300. 0.2922E-01 3 5.0 5.5 1600.0 75.95 36.23 23.45 NO

ITERATION STOPPED AT 50 - MAX NOT FOUND!!!

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1. M:


488. 0.2229 3 5.0 5.5 1600.0 75.95 55.61 34.96 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 0. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
300. 0.2962E-01 3 5.0 5.5 1600.0 75.85 36.23 23.45 NO

ITERATION STOPPED AT 50 - MAX NOT FOUND!!!

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 300. M:


488. 0.2242 3 5.0 5.5 1600.0 75.85 55.61 34.96 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 1. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
389. 0.1311 3 5.0 5.5 1600.0 74.95 45.69 29.30 NO
400. 0.1454 3 5.0 5.5 1600.0 74.95 46.84 30.01 NO
500. 0.2477 3 5.0 5.5 1600.0 74.95 56.67 35.55 NO
600. 0.3178 3 5.0 5.5 1600.0 74.95 66.33 40.99 NO
700. 0.3546 3 5.0 5.5 1600.0 74.95 75.90 46.46 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 389. M:


807. 0.3655 3 5.0 5.5 1600.0 74.95 86.15 52.37 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 3. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
708. 0.3810 3 5.0 5.5 1600.0 72.95 76.66 46.90 NO
800. 0.3860 3 5.0 5.5 1600.0 72.95 85.39 51.94 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 708. M:


781. 0.3864 3 5.0 5.5 1600.0 72.95 83.69 50.95 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

437
*** TERRAIN HEIGHT OF 5. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
875. 0.3975 3 5.0 5.5 1600.0 70.95 92.46 56.04 NO
900. 0.3929 3 5.0 5.5 1600.0 70.95 94.80 57.40 NO
1000. 0.3708 3 5.0 5.5 1600.0 70.95 104.14 62.85 NO
1100. 0.3454 3 5.0 5.5 1600.0 70.95 113.39 68.28 NO
1200. 0.3196 3 5.0 5.5 1600.0 70.95 122.58 73.69 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 875. M:


875. 0.3975 3 5.0 5.5 1600.0 70.95 92.46 56.04 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 7. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1200. 0.3279 3 5.0 5.5 1600.0 68.95 122.58 73.69 NO
1300. 0.3013 3 5.0 5.5 1600.0 68.95 131.70 79.07 NO
1400. 0.2766 3 5.0 5.5 1600.0 68.95 140.76 84.44 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1200. M:


1200. 0.3279 3 5.0 5.5 1600.0 68.95 122.58 73.69 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 8. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1430. 0.2721 3 5.0 5.5 1600.0 67.95 143.47 86.04 NO
1500. 0.2563 3 5.0 5.5 1600.0 67.95 149.77 89.78 NO
1600. 0.2355 3 5.0 5.5 1600.0 67.95 158.71 95.10 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1430. M:


1430. 0.2721 3 5.0 5.5 1600.0 67.95 143.47 86.04 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 13. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1600. 0.2442 3 5.0 5.5 1600.0 62.95 158.71 95.10 NO
1700. 0.2240 3 5.0 5.5 1600.0 62.95 167.60 100.40 NO
1800. 0.2061 3 5.0 5.5 1600.0 62.95 176.45 105.68 NO
1900. 0.1901 3 5.0 5.5 1600.0 62.95 185.24 110.93 NO
2000. 0.1758 3 5.0 5.5 1600.0 62.95 193.99 116.17 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1600. M:


1600. 0.2442 3 5.0 5.5 1600.0 62.95 158.71 95.10 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 16. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

438
DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA
(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
2070. 0.1689 3 5.0 5.5 1600.0 59.95 200.09 119.83 NO
2100. 0.1651 3 5.0 5.5 1600.0 59.95 202.70 121.39 NO
2200. 0.1533 3 5.0 5.5 1600.0 59.95 211.36 126.60 NO
2300. 0.1427 3 5.0 5.5 1600.0 59.95 219.99 131.78 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 2070. M:


2070. 0.1689 3 5.0 5.5 1600.0 59.95 200.09 119.83 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 16. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
2340. 0.1388 3 5.0 5.5 1600.0 59.85 223.43 133.85 NO
2400. 0.1332 3 5.0 5.5 1600.0 59.85 228.58 136.95 NO
2500. 0.1246 3 5.0 5.5 1600.0 59.85 237.13 142.10 NO
2600. 0.1168 3 5.0 5.5 1600.0 59.85 245.65 147.24 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 2340. M:


2340. 0.1388 3 5.0 5.5 1600.0 59.85 223.43 133.85 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 23. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
2630. 0.1166 3 5.0 5.5 1600.0 52.95 248.19 148.78 NO
2700. 0.1116 3 5.0 5.5 1600.0 52.95 254.13 152.36 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 2630. M:


2630. 0.1166 3 5.0 5.5 1600.0 52.95 248.19 148.78 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 25. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
2720. 0.1107 3 5.0 5.5 1600.0 50.95 255.82 153.38 NO
2800. 0.1053 3 5.0 5.5 1600.0 50.95 262.58 157.47 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 2720. M:


2720. 0.1107 3 5.0 5.5 1600.0 50.95 255.82 153.38 NO

DWASH= MEANS NO CALC MADE (CONC = 0.0)


DWASH=NO MEANS NO BUILDING DOWNWASH USED
DWASH=HS MEANS HUBER-SNYDER DOWNWASH USED
DWASH=SS MEANS SCHULMAN-SCIRE DOWNWASH USED
DWASH=NA MEANS DOWNWASH NOT APPLICABLE, X<3*LB

********************************************
* SUMMARY OF TERRAIN HEIGHTS ENTERED FOR *
* SIMPLE ELEVATED TERRAIN PROCEDURE *
********************************************

439
TERRAIN DISTANCE RANGE (M)
HT (M) MINIMUM MAXIMUM
------- -------- --------
0.0 1. 300.
0.1 300. 389.
1.0 389. 708.
3.0 708. 875.
5.0 875. 1200.
7.0 1200. 1430.
8.0 1430. 1600.
13.0 1600. 2070.
16.0 2070. 2340.
16.1 2340. 2630.
23.0 2630. 2720.
25.0 2720. 2800.

***************************************
*** SUMMARY OF SCREEN MODEL RESULTS ***
***************************************

CALCULATION MAX CONC DIST TO TERRAIN


PROCEDURE (UG/M**3) MAX (M) HT (M)
-------------- ----------- --------- -------
SIMPLE TERRAIN 0.3975 875. 5.

COMPLEX TERRAIN 0.2674 3000. 32. (24-HR CONC)

440
Fe
10/03/13
03:47:49
*** SCREEN3 MODEL RUN ***
*** VERSION DATED 13043 ***

Fe - HORNO DE LAMINACION - OCTUBRE 2012 - MARZO 2013

COMPLEX TERRAIN INPUTS:


SOURCE TYPE = POINT
EMISSION RATE (G/S) = 0.100000E-01
STACK HT (M) = 25.0000
STACK DIAMETER (M) = 1.5000
STACK VELOCITY (M/S) = 10.9850
STACK GAS TEMP (K) = 604.8570
AMBIENT AIR TEMP (K) = 298.7500
RECEPTOR HEIGHT (M) = 0.0000
URBAN/RURAL OPTION = RURAL

THE REGULATORY (DEFAULT) MIXING HEIGHT OPTION WAS SELECTED.


THE REGULATORY (DEFAULT) ANEMOMETER HEIGHT OF 10.0 METERS WAS ENTERED.

BUOY. FLUX = 30.665 M**4/S**3; MOM. FLUX = 33.526 M**4/S**2.

FINAL STABLE PLUME HEIGHT (M) = 82.3


DISTANCE TO FINAL RISE (M) = 152.8

*VALLEY 24-HR CALCS* **SIMPLE TERRAIN 24-HR CALCS**


TERR MAX 24-HR PLUME HT PLUME HT
HT DIST CONC CONC ABOVE STK CONC ABOVE STK U10M USTK
(M) (M) (UG/M**3) (UG/M**3) BASE (M) (UG/M**3) HGT (M) SC (M/S)
----- ------- ---------- ---------- ------ ---------- ------ -- ---- ----
25. 2800. 0.3325E-01 0.4180E-02 82.3 0.3325E-01 65.7 6 1.0 1.7

10/03/13
03:47:49
*** SCREEN3 MODEL RUN ***
*** VERSION DATED 13043 ***

Fe - HORNO DE LAMINACION - OCTUBRE 2012 - MARZO 2013

SIMPLE TERRAIN INPUTS:


SOURCE TYPE = POINT
EMISSION RATE (G/S) = 0.100000E-01
STACK HEIGHT (M) = 25.0000
STK INSIDE DIAM (M) = 1.5000
STK EXIT VELOCITY (M/S)= 10.9850
STK GAS EXIT TEMP (K) = 604.8570
AMBIENT AIR TEMP (K) = 298.7500
RECEPTOR HEIGHT (M) = 1.6500
URBAN/RURAL OPTION = RURAL
BUILDING HEIGHT (M) = 0.0000
MIN HORIZ BLDG DIM (M) = 0.0000
MAX HORIZ BLDG DIM (M) = 0.0000

THE REGULATORY (DEFAULT) MIXING HEIGHT OPTION WAS SELECTED.


THE REGULATORY (DEFAULT) ANEMOMETER HEIGHT OF 10.0 METERS WAS ENTERED.

BUOY. FLUX = 30.665 M**4/S**3; MOM. FLUX = 33.526 M**4/S**2.

*** STABILITY CLASS 3 ONLY ***


*** ANEMOMETER HEIGHT WIND SPEED OF 5.00 M/S ONLY ***

441
**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 0. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1. 0.000 3 5.0 5.5 1600.0 75.95 0.51 0.50 NO
100. 0.4046E-13 3 5.0 5.5 1600.0 75.95 13.67 9.33 NO
200. 0.4494E-04 3 5.0 5.5 1600.0 75.95 25.25 16.63 NO
300. 0.3698E-02 3 5.0 5.5 1600.0 75.95 36.23 23.45 NO

ITERATION STOPPED AT 50 - MAX NOT FOUND!!!

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1. M:


488. 0.2821E-01 3 5.0 5.5 1600.0 75.95 55.61 34.96 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 0. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
300. 0.3749E-02 3 5.0 5.5 1600.0 75.85 36.23 23.45 NO

ITERATION STOPPED AT 50 - MAX NOT FOUND!!!

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 300. M:


488. 0.2839E-01 3 5.0 5.5 1600.0 75.85 55.61 34.96 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 1. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
389. 0.1659E-01 3 5.0 5.5 1600.0 74.95 45.69 29.30 NO
400. 0.1840E-01 3 5.0 5.5 1600.0 74.95 46.84 30.01 NO
500. 0.3136E-01 3 5.0 5.5 1600.0 74.95 56.67 35.55 NO
600. 0.4023E-01 3 5.0 5.5 1600.0 74.95 66.33 40.99 NO
700. 0.4489E-01 3 5.0 5.5 1600.0 74.95 75.90 46.46 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 389. M:


807. 0.4626E-01 3 5.0 5.5 1600.0 74.95 86.15 52.37 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 3. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
708. 0.4823E-01 3 5.0 5.5 1600.0 72.95 76.66 46.90 NO
800. 0.4886E-01 3 5.0 5.5 1600.0 72.95 85.39 51.94 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 708. M:


781. 0.4891E-01 3 5.0 5.5 1600.0 72.95 83.69 50.95 NO

442
**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 5. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
875. 0.5031E-01 3 5.0 5.5 1600.0 70.95 92.46 56.04 NO
900. 0.4974E-01 3 5.0 5.5 1600.0 70.95 94.80 57.40 NO
1000. 0.4694E-01 3 5.0 5.5 1600.0 70.95 104.14 62.85 NO
1100. 0.4373E-01 3 5.0 5.5 1600.0 70.95 113.39 68.28 NO
1200. 0.4045E-01 3 5.0 5.5 1600.0 70.95 122.58 73.69 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 875. M:


875. 0.5031E-01 3 5.0 5.5 1600.0 70.95 92.46 56.04 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 7. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1200. 0.4151E-01 3 5.0 5.5 1600.0 68.95 122.58 73.69 NO
1300. 0.3814E-01 3 5.0 5.5 1600.0 68.95 131.70 79.07 NO
1400. 0.3501E-01 3 5.0 5.5 1600.0 68.95 140.76 84.44 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1200. M:


1200. 0.4151E-01 3 5.0 5.5 1600.0 68.95 122.58 73.69 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 8. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1430. 0.3445E-01 3 5.0 5.5 1600.0 67.95 143.47 86.04 NO
1500. 0.3244E-01 3 5.0 5.5 1600.0 67.95 149.77 89.78 NO
1600. 0.2981E-01 3 5.0 5.5 1600.0 67.95 158.71 95.10 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1430. M:


1430. 0.3445E-01 3 5.0 5.5 1600.0 67.95 143.47 86.04 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 13. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1600. 0.3091E-01 3 5.0 5.5 1600.0 62.95 158.71 95.10 NO
1700. 0.2836E-01 3 5.0 5.5 1600.0 62.95 167.60 100.40 NO
1800. 0.2609E-01 3 5.0 5.5 1600.0 62.95 176.45 105.68 NO
1900. 0.2406E-01 3 5.0 5.5 1600.0 62.95 185.24 110.93 NO
2000. 0.2225E-01 3 5.0 5.5 1600.0 62.95 193.99 116.17 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1600. M:


1600. 0.3091E-01 3 5.0 5.5 1600.0 62.95 158.71 95.10 NO

**********************************

443
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 16. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
2070. 0.2138E-01 3 5.0 5.5 1600.0 59.95 200.09 119.83 NO
2100. 0.2090E-01 3 5.0 5.5 1600.0 59.95 202.70 121.39 NO
2200. 0.1940E-01 3 5.0 5.5 1600.0 59.95 211.36 126.60 NO
2300. 0.1807E-01 3 5.0 5.5 1600.0 59.95 219.99 131.78 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 2070. M:


2070. 0.2138E-01 3 5.0 5.5 1600.0 59.95 200.09 119.83 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 16. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
2340. 0.1757E-01 3 5.0 5.5 1600.0 59.85 223.43 133.85 NO
2400. 0.1687E-01 3 5.0 5.5 1600.0 59.85 228.58 136.95 NO
2500. 0.1577E-01 3 5.0 5.5 1600.0 59.85 237.13 142.10 NO
2600. 0.1479E-01 3 5.0 5.5 1600.0 59.85 245.65 147.24 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 2340. M:


2340. 0.1757E-01 3 5.0 5.5 1600.0 59.85 223.43 133.85 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 23. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
2630. 0.1477E-01 3 5.0 5.5 1600.0 52.95 248.19 148.78 NO
2700. 0.1412E-01 3 5.0 5.5 1600.0 52.95 254.13 152.36 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 2630. M:


2630. 0.1477E-01 3 5.0 5.5 1600.0 52.95 248.19 148.78 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 25. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
2720. 0.1401E-01 3 5.0 5.5 1600.0 50.95 255.82 153.38 NO
2800. 0.1333E-01 3 5.0 5.5 1600.0 50.95 262.58 157.47 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 2720. M:


2720. 0.1401E-01 3 5.0 5.5 1600.0 50.95 255.82 153.38 NO

DWASH= MEANS NO CALC MADE (CONC = 0.0)


DWASH=NO MEANS NO BUILDING DOWNWASH USED
DWASH=HS MEANS HUBER-SNYDER DOWNWASH USED
DWASH=SS MEANS SCHULMAN-SCIRE DOWNWASH USED
DWASH=NA MEANS DOWNWASH NOT APPLICABLE, X<3*LB

444
********************************************
* SUMMARY OF TERRAIN HEIGHTS ENTERED FOR *
* SIMPLE ELEVATED TERRAIN PROCEDURE *
********************************************

TERRAIN DISTANCE RANGE (M)


HT (M) MINIMUM MAXIMUM
------- -------- --------
0.0 1. 300.
0.1 300. 389.
1.0 389. 708.
3.0 708. 875.
5.0 875. 1200.
7.0 1200. 1430.
8.0 1430. 1600.
13.0 1600. 2070.
16.0 2070. 2340.
16.1 2340. 2630.
23.0 2630. 2720.
25.0 2720. 2800.

***************************************
*** SUMMARY OF SCREEN MODEL RESULTS ***
***************************************

CALCULATION MAX CONC DIST TO TERRAIN


PROCEDURE (UG/M**3) MAX (M) HT (M)
-------------- ----------- --------- -------
SIMPLE TERRAIN 0.5031E-01 875. 5.

COMPLEX TERRAIN 0.3384E-01 3000. 32. (24-HR CONC)

445
CO
08/12/13
11:43:15
*** SCREEN3 MODEL RUN ***
*** VERSION DATED 96043 ***

CO - HORNO DE LAMINACION - OCTUBRE 2012 - MARZO 2013

COMPLEX TERRAIN INPUTS:


SOURCE TYPE = POINT
EMISSION RATE (G/S) = 0.360000E-01
STACK HT (M) = 25.0000
STACK DIAMETER (M) = 1.5000
STACK VELOCITY (M/S) = 10.9850
STACK GAS TEMP (K) = 604.8570
AMBIENT AIR TEMP (K) = 298.7500
RECEPTOR HEIGHT (M) = 0.0000
URBAN/RURAL OPTION = RURAL

THE REGULATORY (DEFAULT) MIXING HEIGHT OPTION WAS SELECTED.


THE REGULATORY (DEFAULT) ANEMOMETER HEIGHT OF 10.0 METERS WAS ENTERED.

BUOY. FLUX = 30.665 M**4/S**3; MOM. FLUX = 33.526 M**4/S**2.

FINAL STABLE PLUME HEIGHT (M) = 82.3


DISTANCE TO FINAL RISE (M) = 152.8

*VALLEY 24-HR CALCS* **SIMPLE TERRAIN 24-HR CALCS**


TERR MAX 24-HR PLUME HT PLUME HT
HT DIST CONC CONC ABOVE STK CONC ABOVE STK U10M USTK
(M) (M) (UG/M**3) (UG/M**3) BASE (M) (UG/M**3) HGT (M) SC (M/S)
----- ------- ---------- ---------- ------ ---------- ------ -- ---- ----
27. 2980. 0.1216 0.1670E-01 82.3 0.1216 65.7 6 1.0 1.7
32. 3000. 0.1218 0.2174E-01 82.3 0.1218 65.7 6 1.0 1.7
08/12/13
11:43:15
*** SCREEN3 MODEL RUN ***
*** VERSION DATED 96043 ***

CO - HORNO DE LAMINACION - OCTUBRE 2012 - MARZO 2013

SIMPLE TERRAIN INPUTS:


SOURCE TYPE = POINT
EMISSION RATE (G/S) = 0.360000E-01
STACK HEIGHT (M) = 25.0000
STK INSIDE DIAM (M) = 1.5000
STK EXIT VELOCITY (M/S)= 10.9850
STK GAS EXIT TEMP (K) = 604.8570
AMBIENT AIR TEMP (K) = 298.7500
RECEPTOR HEIGHT (M) = 1.6500
URBAN/RURAL OPTION = RURAL
BUILDING HEIGHT (M) = 0.0000
MIN HORIZ BLDG DIM (M) = 0.0000
MAX HORIZ BLDG DIM (M) = 0.0000

THE REGULATORY (DEFAULT) MIXING HEIGHT OPTION WAS SELECTED.


THE REGULATORY (DEFAULT) ANEMOMETER HEIGHT OF 10.0 METERS WAS ENTERED.

BUOY. FLUX = 30.665 M**4/S**3; MOM. FLUX = 33.526 M**4/S**2.

*** STABILITY CLASS 3 ONLY ***


*** ANEMOMETER HEIGHT WIND SPEED OF 5.00 M/S ONLY ***

**********************************

446
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 0. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1. 0.000 3 5.0 5.5 1600.0 75.95 0.51 0.50 NO
100. 0.1457E-12 3 5.0 5.5 1600.0 75.95 13.67 9.33 NO
200. 0.1618E-03 3 5.0 5.5 1600.0 75.95 25.25 16.63 NO
300. 0.1331E-01 3 5.0 5.5 1600.0 75.95 36.23 23.45 NO

ITERATION STOPPED AT 50 - MAX NOT FOUND!!!

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1. M:


488. 0.1016 3 5.0 5.5 1600.0 75.95 55.61 34.96 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 0. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
300. 0.1350E-01 3 5.0 5.5 1600.0 75.85 36.23 23.45 NO

ITERATION STOPPED AT 50 - MAX NOT FOUND!!!

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 300. M:


488. 0.1022 3 5.0 5.5 1600.0 75.85 55.61 34.96 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 1. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
389. 0.5973E-01 3 5.0 5.5 1600.0 74.95 45.69 29.30 NO
400. 0.6624E-01 3 5.0 5.5 1600.0 74.95 46.84 30.01 NO
500. 0.1129 3 5.0 5.5 1600.0 74.95 56.67 35.55 NO
600. 0.1448 3 5.0 5.5 1600.0 74.95 66.33 40.99 NO
700. 0.1616 3 5.0 5.5 1600.0 74.95 75.90 46.46 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 389. M:


807. 0.1666 3 5.0 5.5 1600.0 74.95 86.15 52.37 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 3. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
708. 0.1736 3 5.0 5.5 1600.0 72.95 76.66 46.90 NO
800. 0.1759 3 5.0 5.5 1600.0 72.95 85.39 51.94 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 708. M:


781. 0.1761 3 5.0 5.5 1600.0 72.95 83.69 50.95 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***

447
**********************************

*** TERRAIN HEIGHT OF 5. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
875. 0.1811 3 5.0 5.5 1600.0 70.95 92.46 56.04 NO
900. 0.1791 3 5.0 5.5 1600.0 70.95 94.80 57.40 NO
1000. 0.1690 3 5.0 5.5 1600.0 70.95 104.14 62.85 NO
1100. 0.1574 3 5.0 5.5 1600.0 70.95 113.39 68.28 NO
1200. 0.1456 3 5.0 5.5 1600.0 70.95 122.58 73.69 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 875. M:


875. 0.1811 3 5.0 5.5 1600.0 70.95 92.46 56.04 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 7. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1200. 0.1494 3 5.0 5.5 1600.0 68.95 122.58 73.69 NO
1300. 0.1373 3 5.0 5.5 1600.0 68.95 131.70 79.07 NO
1400. 0.1260 3 5.0 5.5 1600.0 68.95 140.76 84.44 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1200. M:


1200. 0.1494 3 5.0 5.5 1600.0 68.95 122.58 73.69 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 8. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1430. 0.1240 3 5.0 5.5 1600.0 67.95 143.47 86.04 NO
1500. 0.1168 3 5.0 5.5 1600.0 67.95 149.77 89.78 NO
1600. 0.1073 3 5.0 5.5 1600.0 67.95 158.71 95.10 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1430. M:


1430. 0.1240 3 5.0 5.5 1600.0 67.95 143.47 86.04 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 13. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1600. 0.1113 3 5.0 5.5 1600.0 62.95 158.71 95.10 NO
1700. 0.1021 3 5.0 5.5 1600.0 62.95 167.60 100.40 NO
1800. 0.9391E-01 3 5.0 5.5 1600.0 62.95 176.45 105.68 NO
1900. 0.8662E-01 3 5.0 5.5 1600.0 62.95 185.24 110.93 NO
2000. 0.8011E-01 3 5.0 5.5 1600.0 62.95 193.99 116.17 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1600. M:


1600. 0.1113 3 5.0 5.5 1600.0 62.95 158.71 95.10 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

448
*** TERRAIN HEIGHT OF 16. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
2070. 0.7695E-01 3 5.0 5.5 1600.0 59.95 200.09 119.83 NO
2100. 0.7522E-01 3 5.0 5.5 1600.0 59.95 202.70 121.39 NO
2200. 0.6986E-01 3 5.0 5.5 1600.0 59.95 211.36 126.60 NO
2300. 0.6504E-01 3 5.0 5.5 1600.0 59.95 219.99 131.78 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 2070. M:


2070. 0.7695E-01 3 5.0 5.5 1600.0 59.95 200.09 119.83 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 16. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
2340. 0.6327E-01 3 5.0 5.5 1600.0 59.85 223.43 133.85 NO
2400. 0.6072E-01 3 5.0 5.5 1600.0 59.85 228.58 136.95 NO
2500. 0.5679E-01 3 5.0 5.5 1600.0 59.85 237.13 142.10 NO
2600. 0.5323E-01 3 5.0 5.5 1600.0 59.85 245.65 147.24 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 2340. M:


2340. 0.6327E-01 3 5.0 5.5 1600.0 59.85 223.43 133.85 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 23. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
2630. 0.5315E-01 3 5.0 5.5 1600.0 52.95 248.19 148.78 NO
2700. 0.5084E-01 3 5.0 5.5 1600.0 52.95 254.13 152.36 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 2630. M:


2630. 0.5315E-01 3 5.0 5.5 1600.0 52.95 248.19 148.78 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 25. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
2720. 0.5043E-01 3 5.0 5.5 1600.0 50.95 255.82 153.38 NO
2800. 0.4799E-01 3 5.0 5.5 1600.0 50.95 262.58 157.47 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 2720. M:


2720. 0.5043E-01 3 5.0 5.5 1600.0 50.95 255.82 153.38 NO

DWASH= MEANS NO CALC MADE (CONC = 0.0)


DWASH=NO MEANS NO BUILDING DOWNWASH USED
DWASH=HS MEANS HUBER-SNYDER DOWNWASH USED
DWASH=SS MEANS SCHULMAN-SCIRE DOWNWASH USED
DWASH=NA MEANS DOWNWASH NOT APPLICABLE, X<3*LB

********************************************
* SUMMARY OF TERRAIN HEIGHTS ENTERED FOR *

449
* SIMPLE ELEVATED TERRAIN PROCEDURE *
********************************************

TERRAIN DISTANCE RANGE (M)


HT (M) MINIMUM MAXIMUM
------- -------- --------
0. 1. 300.
0. 300. 389.
1. 389. 708.
3. 708. 875.
5. 875. 1200.
7. 1200. 1430.
8. 1430. 1600.
13. 1600. 2070.
16. 2070. 2340.
16. 2340. 2630.
23. 2630. 2720.
25. 2720. 2800.

***************************************
*** SUMMARY OF SCREEN MODEL RESULTS ***
***************************************

CALCULATION MAX CONC DIST TO TERRAIN


PROCEDURE (UG/M**3) MAX (M) HT (M)
-------------- ----------- ------- -------
SIMPLE TERRAIN 0.1811 875. 5.

COMPLEX TERRAIN 0.1218 3000. 32. (24-HR CONC)

***************************************************
** REMEMBER TO INCLUDE BACKGROUND CONCENTRATIONS **
***************************************************

450
NO
08/12/13
12:01:47
*** SCREEN3 MODEL RUN ***
*** VERSION DATED 96043 ***

NO - HORNO DE LAMINACION - OCTUBRE 2012 - MARZO 2013

COMPLEX TERRAIN INPUTS:


SOURCE TYPE = POINT
EMISSION RATE (G/S) = 1.30000
STACK HT (M) = 25.0000
STACK DIAMETER (M) = 1.5000
STACK VELOCITY (M/S) = 10.9850
STACK GAS TEMP (K) = 604.8570
AMBIENT AIR TEMP (K) = 298.7500
RECEPTOR HEIGHT (M) = 0.0000
URBAN/RURAL OPTION = RURAL

THE REGULATORY (DEFAULT) MIXING HEIGHT OPTION WAS SELECTED.


THE REGULATORY (DEFAULT) ANEMOMETER HEIGHT OF 10.0 METERS WAS ENTERED.

BUOY. FLUX = 30.665 M**4/S**3; MOM. FLUX = 33.526 M**4/S**2.

FINAL STABLE PLUME HEIGHT (M) = 82.3


DISTANCE TO FINAL RISE (M) = 152.8

*VALLEY 24-HR CALCS* **SIMPLE TERRAIN 24-HR CALCS**


TERR MAX 24-HR PLUME HT PLUME HT
HT DIST CONC CONC ABOVE STK CONC ABOVE STK U10M USTK
(M) (M) (UG/M**3) (UG/M**3) BASE (M) (UG/M**3) HGT (M) SC (M/S)
----- ------- ---------- ---------- ------ ---------- ------ -- ---- ----
25. 2800. 4.322 0.5433 82.3 4.322 65.7 6 1.0 1.7
27. 2980. 4.393 0.6029 82.3 4.393 65.7 6 1.0 1.7
32. 3000. 4.400 0.7849 82.3 4.400 65.7 6 1.0 1.7
08/12/13
12:01:47
*** SCREEN3 MODEL RUN ***
*** VERSION DATED 96043 ***

NO - HORNO DE LAMINACION - OCTUBRE 2012 - MARZO 2013

SIMPLE TERRAIN INPUTS:


SOURCE TYPE = POINT
EMISSION RATE (G/S) = 1.30000
STACK HEIGHT (M) = 25.0000
STK INSIDE DIAM (M) = 1.5000
STK EXIT VELOCITY (M/S)= 10.9850
STK GAS EXIT TEMP (K) = 604.8570
AMBIENT AIR TEMP (K) = 298.7500
RECEPTOR HEIGHT (M) = 1.6500
URBAN/RURAL OPTION = RURAL
BUILDING HEIGHT (M) = 0.0000
MIN HORIZ BLDG DIM (M) = 0.0000
MAX HORIZ BLDG DIM (M) = 0.0000

THE REGULATORY (DEFAULT) MIXING HEIGHT OPTION WAS SELECTED.


THE REGULATORY (DEFAULT) ANEMOMETER HEIGHT OF 10.0 METERS WAS ENTERED.

BUOY. FLUX = 30.665 M**4/S**3; MOM. FLUX = 33.526 M**4/S**2.

*** STABILITY CLASS 3 ONLY ***


*** ANEMOMETER HEIGHT WIND SPEED OF 5.00 M/S ONLY ***

451
**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 0. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1. 0.000 3 5.0 5.5 1600.0 75.95 0.51 0.50 NO
100. 0.5260E-11 3 5.0 5.5 1600.0 75.95 13.67 9.33 NO
200. 0.5843E-02 3 5.0 5.5 1600.0 75.95 25.25 16.63 NO
300. 0.4808 3 5.0 5.5 1600.0 75.95 36.23 23.45 NO

ITERATION STOPPED AT 50 - MAX NOT FOUND!!!

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1. M:


488. 3.667 3 5.0 5.5 1600.0 75.95 55.61 34.96 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 0. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
300. 0.4874 3 5.0 5.5 1600.0 75.85 36.23 23.45 NO

ITERATION STOPPED AT 50 - MAX NOT FOUND!!!

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 300. M:


488. 3.690 3 5.0 5.5 1600.0 75.85 55.61 34.96 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 1. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
389. 2.157 3 5.0 5.5 1600.0 74.95 45.69 29.30 NO
400. 2.392 3 5.0 5.5 1600.0 74.95 46.84 30.01 NO
500. 4.076 3 5.0 5.5 1600.0 74.95 56.67 35.55 NO
600. 5.230 3 5.0 5.5 1600.0 74.95 66.33 40.99 NO
700. 5.835 3 5.0 5.5 1600.0 74.95 75.90 46.46 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 389. M:


807. 6.014 3 5.0 5.5 1600.0 74.95 86.15 52.37 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 3. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
708. 6.270 3 5.0 5.5 1600.0 72.95 76.66 46.90 NO
800. 6.352 3 5.0 5.5 1600.0 72.95 85.39 51.94 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 708. M:


781. 6.358 3 5.0 5.5 1600.0 72.95 83.69 50.95 NO

**********************************

452
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 5. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
875. 6.541 3 5.0 5.5 1600.0 70.95 92.46 56.04 NO
900. 6.466 3 5.0 5.5 1600.0 70.95 94.80 57.40 NO
1000. 6.102 3 5.0 5.5 1600.0 70.95 104.14 62.85 NO
1100. 5.685 3 5.0 5.5 1600.0 70.95 113.39 68.28 NO
1200. 5.259 3 5.0 5.5 1600.0 70.95 122.58 73.69 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 875. M:


875. 6.541 3 5.0 5.5 1600.0 70.95 92.46 56.04 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 7. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1200. 5.396 3 5.0 5.5 1600.0 68.95 122.58 73.69 NO
1300. 4.958 3 5.0 5.5 1600.0 68.95 131.70 79.07 NO
1400. 4.552 3 5.0 5.5 1600.0 68.95 140.76 84.44 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1200. M:


1200. 5.396 3 5.0 5.5 1600.0 68.95 122.58 73.69 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 8. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1430. 4.478 3 5.0 5.5 1600.0 67.95 143.47 86.04 NO
1500. 4.217 3 5.0 5.5 1600.0 67.95 149.77 89.78 NO
1600. 3.876 3 5.0 5.5 1600.0 67.95 158.71 95.10 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1430. M:


1430. 4.478 3 5.0 5.5 1600.0 67.95 143.47 86.04 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 13. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1600. 4.018 3 5.0 5.5 1600.0 62.95 158.71 95.10 NO
1700. 3.687 3 5.0 5.5 1600.0 62.95 167.60 100.40 NO
1800. 3.391 3 5.0 5.5 1600.0 62.95 176.45 105.68 NO
1900. 3.128 3 5.0 5.5 1600.0 62.95 185.24 110.93 NO
2000. 2.893 3 5.0 5.5 1600.0 62.95 193.99 116.17 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1600. M:


1600. 4.018 3 5.0 5.5 1600.0 62.95 158.71 95.10 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***

453
**********************************

*** TERRAIN HEIGHT OF 16. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
2070. 2.779 3 5.0 5.5 1600.0 59.95 200.09 119.83 NO
2100. 2.716 3 5.0 5.5 1600.0 59.95 202.70 121.39 NO
2200. 2.523 3 5.0 5.5 1600.0 59.95 211.36 126.60 NO
2300. 2.349 3 5.0 5.5 1600.0 59.95 219.99 131.78 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 2070. M:


2070. 2.779 3 5.0 5.5 1600.0 59.95 200.09 119.83 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 16. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
2340. 2.285 3 5.0 5.5 1600.0 59.85 223.43 133.85 NO
2400. 2.192 3 5.0 5.5 1600.0 59.85 228.58 136.95 NO
2500. 2.051 3 5.0 5.5 1600.0 59.85 237.13 142.10 NO
2600. 1.922 3 5.0 5.5 1600.0 59.85 245.65 147.24 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 2340. M:


2340. 2.285 3 5.0 5.5 1600.0 59.85 223.43 133.85 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 23. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
2630. 1.919 3 5.0 5.5 1600.0 52.95 248.19 148.78 NO
2700. 1.836 3 5.0 5.5 1600.0 52.95 254.13 152.36 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 2630. M:


2630. 1.919 3 5.0 5.5 1600.0 52.95 248.19 148.78 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 25. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
2720. 1.821 3 5.0 5.5 1600.0 50.95 255.82 153.38 NO
2800. 1.733 3 5.0 5.5 1600.0 50.95 262.58 157.47 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 2720. M:


2720. 1.821 3 5.0 5.5 1600.0 50.95 255.82 153.38 NO

DWASH= MEANS NO CALC MADE (CONC = 0.0)


DWASH=NO MEANS NO BUILDING DOWNWASH USED
DWASH=HS MEANS HUBER-SNYDER DOWNWASH USED
DWASH=SS MEANS SCHULMAN-SCIRE DOWNWASH USED
DWASH=NA MEANS DOWNWASH NOT APPLICABLE, X<3*LB

********************************************

454
* SUMMARY OF TERRAIN HEIGHTS ENTERED FOR *
* SIMPLE ELEVATED TERRAIN PROCEDURE *
********************************************

TERRAIN DISTANCE RANGE (M)


HT (M) MINIMUM MAXIMUM
------- -------- --------
0. 1. 300.
0. 300. 389.
1. 389. 708.
3. 708. 875.
5. 875. 1200.
7. 1200. 1430.
8. 1430. 1600.
13. 1600. 2070.
16. 2070. 2340.
16. 2340. 2630.
23. 2630. 2720.
25. 2720. 2800.

***************************************
*** SUMMARY OF SCREEN MODEL RESULTS ***
***************************************

CALCULATION MAX CONC DIST TO TERRAIN


PROCEDURE (UG/M**3) MAX (M) HT (M)
-------------- ----------- ------- -------
SIMPLE TERRAIN 6.541 875. 5.

COMPLEX TERRAIN 4.400 3000. 32. (24-HR CONC)

***************************************************
** REMEMBER TO INCLUDE BACKGROUND CONCENTRATIONS **
***************************************************

455
456
PTS
08/12/13
12:45:42
*** SCREEN3 MODEL RUN ***
*** VERSION DATED 96043 ***

PTS - HORNO DE HIERRO ESPONJA - OCTUBRE 2012 - MARZO 2013

COMPLEX TERRAIN INPUTS:


SOURCE TYPE = POINT
EMISSION RATE (G/S) = 1.28800
STACK HT (M) = 29.0000
STACK DIAMETER (M) = 1.6000
STACK VELOCITY (M/S) = 14.3350
STACK GAS TEMP (K) = 438.6230
AMBIENT AIR TEMP (K) = 299.7170
RECEPTOR HEIGHT (M) = 0.0000
URBAN/RURAL OPTION = RURAL

THE REGULATORY (DEFAULT) MIXING HEIGHT OPTION WAS SELECTED.


THE REGULATORY (DEFAULT) ANEMOMETER HEIGHT OF 10.0 METERS WAS ENTERED.

BUOY. FLUX = 28.491 M**4/S**3; MOM. FLUX = 89.866 M**4/S**2.

FINAL STABLE PLUME HEIGHT (M) = 84.9


DISTANCE TO FINAL RISE (M) = 153.0

*VALLEY 24-HR CALCS* **SIMPLE TERRAIN 24-HR CALCS**


TERR MAX 24-HR PLUME HT PLUME HT
HT DIST CONC CONC ABOVE STK CONC ABOVE STK U10M USTK
(M) (M) (UG/M**3) (UG/M**3) BASE (M) (UG/M**3) HGT (M) SC (M/S)
----- ------- ---------- ---------- ------ ---------- ------ -- ---- ----
29. 3020. 4.676 0.5692 84.9 4.676 62.4 6 1.0 1.8
32. 3090. 4.676 0.6621 84.9 4.676 62.4 6 1.0 1.8
34. 3250. 4.671 0.7173 84.9 4.671 62.4 6 1.0 1.8
08/12/13
12:45:42
*** SCREEN3 MODEL RUN ***
*** VERSION DATED 96043 ***

PTS - HORNO DE HIERRO ESPONJA - OCTUBRE 2012 - MARZO 2013

SIMPLE TERRAIN INPUTS:


SOURCE TYPE = POINT
EMISSION RATE (G/S) = 1.28800
STACK HEIGHT (M) = 29.0000
STK INSIDE DIAM (M) = 1.6000
STK EXIT VELOCITY (M/S)= 14.3350
STK GAS EXIT TEMP (K) = 438.6230
AMBIENT AIR TEMP (K) = 299.7170
RECEPTOR HEIGHT (M) = 1.6500
URBAN/RURAL OPTION = RURAL
BUILDING HEIGHT (M) = 0.0000
MIN HORIZ BLDG DIM (M) = 0.0000
MAX HORIZ BLDG DIM (M) = 0.0000

THE REGULATORY (DEFAULT) MIXING HEIGHT OPTION WAS SELECTED.


THE REGULATORY (DEFAULT) ANEMOMETER HEIGHT OF 10.0 METERS WAS ENTERED.

BUOY. FLUX = 28.491 M**4/S**3; MOM. FLUX = 89.866 M**4/S**2.

*** STABILITY CLASS 3 ONLY ***


*** ANEMOMETER HEIGHT WIND SPEED OF 5.00 M/S ONLY ***

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 0. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1. 0.000 3 5.0 5.6 1600.0 76.51 0.75 0.74 NO

457
100. 0.1302E-11 3 5.0 5.6 1600.0 76.51 13.59 9.20 NO
200. 0.3948E-02 3 5.0 5.6 1600.0 76.51 25.13 16.45 NO
300. 0.3982 3 5.0 5.6 1600.0 76.51 36.09 23.23 NO
400. 1.953 3 5.0 5.6 1600.0 76.51 46.67 29.73 NO
500. 3.497 3 5.0 5.6 1600.0 76.51 56.43 35.16 NO

ITERATION STOPPED AT 50 - MAX NOT FOUND!!!

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1. M:


788. 5.584 3 5.0 5.6 1600.0 76.51 84.19 51.06 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 0. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
570. 4.399 3 5.0 5.6 1600.0 76.41 63.22 39.00 NO
600. 4.699 3 5.0 5.6 1600.0 76.41 66.12 40.65 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 570. M:


832. 5.626 3 5.0 5.6 1600.0 76.41 88.35 53.48 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 1. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
608. 4.968 3 5.0 5.6 1600.0 75.51 66.89 41.09 NO
700. 5.541 3 5.0 5.6 1600.0 75.51 75.72 46.16 NO
800. 5.758 3 5.0 5.6 1600.0 75.51 85.23 51.67 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 608. M:


821. 5.763 3 5.0 5.6 1600.0 75.51 87.31 52.88 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 3. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
824. 6.077 3 5.0 5.6 1600.0 73.51 87.50 52.99 NO
900. 5.961 3 5.0 5.6 1600.0 73.51 94.66 57.16 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 824. M:


824. 6.077 3 5.0 5.6 1600.0 73.51 87.50 52.99 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 5. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
901. 6.229 3 5.0 5.6 1600.0 71.51 94.75 57.21 NO
1000. 5.898 3 5.0 5.6 1600.0 71.51 104.00 62.63 NO
1100. 5.507 3 5.0 5.6 1600.0 71.51 113.27 68.08 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 901. M:


901. 6.229 3 5.0 5.6 1600.0 71.51 94.75 57.21 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

458
*** TERRAIN HEIGHT OF 7. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1120. 5.588 3 5.0 5.6 1600.0 69.51 115.12 69.16 NO
1200. 5.237 3 5.0 5.6 1600.0 69.51 122.47 73.50 NO
1300. 4.816 3 5.0 5.6 1600.0 69.51 131.60 78.90 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1120. M:


1120. 5.588 3 5.0 5.6 1600.0 69.51 115.12 69.16 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 11. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1350. 4.808 3 5.0 5.6 1600.0 65.51 136.14 81.59 NO
1400. 4.597 3 5.0 5.6 1600.0 65.51 140.67 84.27 NO
1500. 4.207 3 5.0 5.6 1600.0 65.51 149.67 89.63 NO
1600. 3.857 3 5.0 5.6 1600.0 65.51 158.62 94.95 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1350. M:


1350. 4.808 3 5.0 5.6 1600.0 65.51 136.14 81.59 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 14. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1650. 3.772 3 5.0 5.6 1600.0 62.51 163.08 97.61 NO
1700. 3.613 3 5.0 5.6 1600.0 62.51 167.52 100.26 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1650. M:


1650. 3.772 3 5.0 5.6 1600.0 62.51 163.08 97.61 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 17. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1780. 3.435 3 5.0 5.6 1600.0 59.51 174.60 104.49 NO
1800. 3.378 3 5.0 5.6 1600.0 59.51 176.37 105.55 NO
1900. 3.110 3 5.0 5.6 1600.0 59.51 185.17 110.81 NO
2000. 2.872 3 5.0 5.6 1600.0 59.51 193.92 116.05 NO
2100. 2.659 3 5.0 5.6 1600.0 59.51 202.63 121.28 NO
2200. 2.469 3 5.0 5.6 1600.0 59.51 211.30 126.49 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1780. M:


1780. 3.435 3 5.0 5.6 1600.0 59.51 174.60 104.49 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 29. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
2220. 2.531 3 5.0 5.6 1600.0 47.61 213.03 127.53 NO
2300. 2.384 3 5.0 5.6 1600.0 47.61 219.93 131.68 NO
2400. 2.219 3 5.0 5.6 1600.0 47.61 228.52 136.85 NO
2500. 2.070 3 5.0 5.6 1600.0 47.61 237.07 142.00 NO
2600. 1.936 3 5.0 5.6 1600.0 47.61 245.59 147.14 NO

459
2700. 1.814 3 5.0 5.6 1600.0 47.61 254.07 152.27 NO
2800. 1.704 3 5.0 5.6 1600.0 47.61 262.52 157.38 NO
2900. 1.604 3 5.0 5.6 1600.0 47.61 270.94 162.47 NO
3000. 1.513 3 5.0 5.6 1600.0 47.61 279.33 167.56 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 2220. M:


2220. 2.531 3 5.0 5.6 1600.0 47.61 213.03 127.53 NO

DWASH= MEANS NO CALC MADE (CONC = 0.0)


DWASH=NO MEANS NO BUILDING DOWNWASH USED
DWASH=HS MEANS HUBER-SNYDER DOWNWASH USED
DWASH=SS MEANS SCHULMAN-SCIRE DOWNWASH USED
DWASH=NA MEANS DOWNWASH NOT APPLICABLE, X<3*LB

********************************************
* SUMMARY OF TERRAIN HEIGHTS ENTERED FOR *
* SIMPLE ELEVATED TERRAIN PROCEDURE *
********************************************

TERRAIN DISTANCE RANGE (M)


HT (M) MINIMUM MAXIMUM
------- -------- --------
0. 1. 570.
0. 570. 608.
1. 608. 824.
3. 824. 901.
5. 901. 1120.
7. 1120. 1350.
11. 1350. 1650.
14. 1650. 1780.
17. 1780. 2220.
29. 2220. 3020.

***************************************
*** SUMMARY OF SCREEN MODEL RESULTS ***
***************************************

CALCULATION MAX CONC DIST TO TERRAIN


PROCEDURE (UG/M**3) MAX (M) HT (M)
-------------- ----------- ------- -------
SIMPLE TERRAIN 6.229 901. 5.

COMPLEX TERRAIN 4.676 3090. 32. (24-HR CONC)

***************************************************
** REMEMBER TO INCLUDE BACKGROUND CONCENTRATIONS **

***************************************************

460
Fe
10/03/13
04:05:40
*** SCREEN3 MODEL RUN ***
*** VERSION DATED 13043 ***

Fe- HIERRO ESPONJA - OCTUBRE 2012 - MARZO 2013

COMPLEX TERRAIN INPUTS:


SOURCE TYPE = POINT
EMISSION RATE (G/S) = 0.460000E-01
STACK HT (M) = 29.0000
STACK DIAMETER (M) = 1.6000
STACK VELOCITY (M/S) = 14.3350
STACK GAS TEMP (K) = 438.6230
AMBIENT AIR TEMP (K) = 299.7170
RECEPTOR HEIGHT (M) = 0.0000
URBAN/RURAL OPTION = RURAL

THE REGULATORY (DEFAULT) MIXING HEIGHT OPTION WAS SELECTED.


THE REGULATORY (DEFAULT) ANEMOMETER HEIGHT OF 10.0 METERS WAS ENTERED.

BUOY. FLUX = 28.491 M**4/S**3; MOM. FLUX = 89.866 M**4/S**2.

FINAL STABLE PLUME HEIGHT (M) = 84.9


DISTANCE TO FINAL RISE (M) = 153.0

*VALLEY 24-HR CALCS* **SIMPLE TERRAIN 24-HR CALCS**


TERR MAX 24-HR PLUME HT PLUME HT
HT DIST CONC CONC ABOVE STK CONC ABOVE STK U10M USTK
(M) (M) (UG/M**3) (UG/M**3) BASE (M) (UG/M**3) HGT (M) SC (M/S)
----- ------- ---------- ---------- ------ ---------- ------ -- ---- ----
29. 3020. 0.1670 0.2033E-01 84.9 0.1670 62.4 6 1.0 1.8
32. 3090. 0.1670 0.2365E-01 84.9 0.1670 62.4 6 1.0 1.8
34. 3250. 0.1668 0.2562E-01 84.9 0.1668 62.4 6 1.0 1.8
10/03/13
04:05:40
*** SCREEN3 MODEL RUN ***
*** VERSION DATED 13043 ***

Fe- HIERRO ESPONJA - OCTUBRE 2012 - MARZO 2013

SIMPLE TERRAIN INPUTS:


SOURCE TYPE = POINT
EMISSION RATE (G/S) = 0.460000E-01
STACK HEIGHT (M) = 29.0000
STK INSIDE DIAM (M) = 1.6000
STK EXIT VELOCITY (M/S)= 14.3350
STK GAS EXIT TEMP (K) = 438.6230
AMBIENT AIR TEMP (K) = 299.7170
RECEPTOR HEIGHT (M) = 1.6500
URBAN/RURAL OPTION = RURAL
BUILDING HEIGHT (M) = 0.0000
MIN HORIZ BLDG DIM (M) = 0.0000
MAX HORIZ BLDG DIM (M) = 0.0000

THE REGULATORY (DEFAULT) MIXING HEIGHT OPTION WAS SELECTED.


THE REGULATORY (DEFAULT) ANEMOMETER HEIGHT OF 10.0 METERS WAS ENTERED.

BUOY. FLUX = 28.491 M**4/S**3; MOM. FLUX = 89.866 M**4/S**2.

*** STABILITY CLASS 3 ONLY ***


*** ANEMOMETER HEIGHT WIND SPEED OF 5.00 M/S ONLY ***

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 0. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----

461
1. 0.000 3 5.0 5.6 1600.0 76.51 0.75 0.74 NO
100. 0.4649E-13 3 5.0 5.6 1600.0 76.51 13.59 9.20 NO
200. 0.1410E-03 3 5.0 5.6 1600.0 76.51 25.13 16.45 NO
300. 0.1422E-01 3 5.0 5.6 1600.0 76.51 36.09 23.23 NO
400. 0.6976E-01 3 5.0 5.6 1600.0 76.51 46.67 29.73 NO
500. 0.1249 3 5.0 5.6 1600.0 76.51 56.43 35.16 NO

ITERATION STOPPED AT 50 - MAX NOT FOUND!!!

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1. M:


788. 0.1994 3 5.0 5.6 1600.0 76.51 84.19 51.06 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 0. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
570. 0.1571 3 5.0 5.6 1600.0 76.41 63.22 39.00 NO
600. 0.1678 3 5.0 5.6 1600.0 76.41 66.12 40.65 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 570. M:


833. 0.2009 3 5.0 5.6 1600.0 76.41 88.45 53.54 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 1. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
608. 0.1774 3 5.0 5.6 1600.0 75.51 66.89 41.09 NO
700. 0.1979 3 5.0 5.6 1600.0 75.51 75.72 46.16 NO
800. 0.2056 3 5.0 5.6 1600.0 75.51 85.23 51.67 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 608. M:


821. 0.2058 3 5.0 5.6 1600.0 75.51 87.31 52.88 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 3. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
824. 0.2170 3 5.0 5.6 1600.0 73.51 87.50 52.99 NO
900. 0.2129 3 5.0 5.6 1600.0 73.51 94.66 57.16 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 824. M:


824. 0.2170 3 5.0 5.6 1600.0 73.51 87.50 52.99 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 5. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
901. 0.2225 3 5.0 5.6 1600.0 71.51 94.75 57.21 NO
1000. 0.2107 3 5.0 5.6 1600.0 71.51 104.00 62.63 NO
1100. 0.1967 3 5.0 5.6 1600.0 71.51 113.27 68.08 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 901. M:


901. 0.2225 3 5.0 5.6 1600.0 71.51 94.75 57.21 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

462
*** TERRAIN HEIGHT OF 7. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1120. 0.1996 3 5.0 5.6 1600.0 69.51 115.12 69.16 NO
1200. 0.1870 3 5.0 5.6 1600.0 69.51 122.47 73.50 NO
1300. 0.1720 3 5.0 5.6 1600.0 69.51 131.60 78.90 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1120. M:


1120. 0.1996 3 5.0 5.6 1600.0 69.51 115.12 69.16 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 11. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1350. 0.1717 3 5.0 5.6 1600.0 65.51 136.14 81.59 NO
1400. 0.1642 3 5.0 5.6 1600.0 65.51 140.67 84.27 NO
1500. 0.1502 3 5.0 5.6 1600.0 65.51 149.67 89.63 NO
1600. 0.1378 3 5.0 5.6 1600.0 65.51 158.62 94.95 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1350. M:


1350. 0.1717 3 5.0 5.6 1600.0 65.51 136.14 81.59 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 14. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1650. 0.1347 3 5.0 5.6 1600.0 62.51 163.08 97.61 NO
1700. 0.1291 3 5.0 5.6 1600.0 62.51 167.52 100.26 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1650. M:


1650. 0.1347 3 5.0 5.6 1600.0 62.51 163.08 97.61 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 17. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1780. 0.1227 3 5.0 5.6 1600.0 59.51 174.60 104.49 NO
1800. 0.1206 3 5.0 5.6 1600.0 59.51 176.37 105.55 NO
1900. 0.1111 3 5.0 5.6 1600.0 59.51 185.17 110.81 NO
2000. 0.1026 3 5.0 5.6 1600.0 59.51 193.92 116.05 NO
2100. 0.9497E-01 3 5.0 5.6 1600.0 59.51 202.63 121.28 NO
2200. 0.8818E-01 3 5.0 5.6 1600.0 59.51 211.30 126.49 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1780. M:


1780. 0.1227 3 5.0 5.6 1600.0 59.51 174.60 104.49 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 29. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
2220. 0.9038E-01 3 5.0 5.6 1600.0 47.61 213.03 127.53 NO
2300. 0.8515E-01 3 5.0 5.6 1600.0 47.61 219.93 131.68 NO
2400. 0.7924E-01 3 5.0 5.6 1600.0 47.61 228.52 136.85 NO
2500. 0.7392E-01 3 5.0 5.6 1600.0 47.61 237.07 142.00 NO

463
2600. 0.6913E-01 3 5.0 5.6 1600.0 47.61 245.59 147.14 NO
2700. 0.6480E-01 3 5.0 5.6 1600.0 47.61 254.07 152.27 NO
2800. 0.6087E-01 3 5.0 5.6 1600.0 47.61 262.52 157.38 NO
2900. 0.5729E-01 3 5.0 5.6 1600.0 47.61 270.94 162.47 NO
3000. 0.5402E-01 3 5.0 5.6 1600.0 47.61 279.33 167.56 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 2220. M:


2220. 0.9038E-01 3 5.0 5.6 1600.0 47.61 213.03 127.53 NO

DWASH= MEANS NO CALC MADE (CONC = 0.0)


DWASH=NO MEANS NO BUILDING DOWNWASH USED
DWASH=HS MEANS HUBER-SNYDER DOWNWASH USED
DWASH=SS MEANS SCHULMAN-SCIRE DOWNWASH USED
DWASH=NA MEANS DOWNWASH NOT APPLICABLE, X<3*LB

********************************************
* SUMMARY OF TERRAIN HEIGHTS ENTERED FOR *
* SIMPLE ELEVATED TERRAIN PROCEDURE *
********************************************

TERRAIN DISTANCE RANGE (M)


HT (M) MINIMUM MAXIMUM
------- -------- --------
0.0 1. 570.
0.1 570. 608.
1.0 608. 824.
3.0 824. 901.
5.0 901. 1120.
7.0 1120. 1350.
11.0 1350. 1650.
14.0 1650. 1780.
17.0 1780. 2220.
28.9 2220. 3020.

***************************************
*** SUMMARY OF SCREEN MODEL RESULTS ***
***************************************

CALCULATION MAX CONC DIST TO TERRAIN


PROCEDURE (UG/M**3) MAX (M) HT (M)
-------------- ----------- --------- -------
SIMPLE TERRAIN 0.2225 901. 5.

COMPLEX TERRAIN 0.1670 3090. 32. (24-HR CONC)

464
CO
08/12/13
13:03:25
*** SCREEN3 MODEL RUN ***
*** VERSION DATED 13043 ***

CO - HIERRO ESPONJA - OCTUBRE 2012 - MARZO 2013

COMPLEX TERRAIN INPUTS:


SOURCE TYPE = POINT
EMISSION RATE (G/S) = 1.26200
STACK HT (M) = 29.0000
STACK DIAMETER (M) = 1.6000
STACK VELOCITY (M/S) = 14.3350
STACK GAS TEMP (K) = 438.6230
AMBIENT AIR TEMP (K) = 299.7170
RECEPTOR HEIGHT (M) = 0.0000
URBAN/RURAL OPTION = RURAL

THE REGULATORY (DEFAULT) MIXING HEIGHT OPTION WAS SELECTED.


THE REGULATORY (DEFAULT) ANEMOMETER HEIGHT OF 10.0 METERS WAS ENTERED.

BUOY. FLUX = 28.491 M**4/S**3; MOM. FLUX = 89.866 M**4/S**2.

FINAL STABLE PLUME HEIGHT (M) = 84.9


DISTANCE TO FINAL RISE (M) = 153.0

*VALLEY 24-HR CALCS* **SIMPLE TERRAIN 24-HR CALCS**


TERR MAX 24-HR PLUME HT PLUME HT
HT DIST CONC CONC ABOVE STK CONC ABOVE STK U10M USTK
(M) (M) (UG/M**3) (UG/M**3) BASE (M) (UG/M**3) HGT (M) SC (M/S)
----- ------- ---------- ---------- ------ ---------- ------ -- ---- ----
29. 3020. 4.582 0.5577 84.9 4.582 62.4 6 1.0 1.8
32. 3090. 4.582 0.6487 84.9 4.582 62.4 6 1.0 1.8
34. 3250. 4.577 0.7028 84.9 4.577 62.4 6 1.0 1.8
08/12/13
13:03:25
*** SCREEN3 MODEL RUN ***
*** VERSION DATED 13043 ***

CO - HIERRO ESPONJA - OCTUBRE 2012 - MARZO 2013

SIMPLE TERRAIN INPUTS:


SOURCE TYPE = POINT
EMISSION RATE (G/S) = 1.26200
STACK HEIGHT (M) = 29.0000
STK INSIDE DIAM (M) = 1.6000
STK EXIT VELOCITY (M/S)= 14.3350
STK GAS EXIT TEMP (K) = 438.6230
AMBIENT AIR TEMP (K) = 299.7170
RECEPTOR HEIGHT (M) = 1.6500
URBAN/RURAL OPTION = RURAL
BUILDING HEIGHT (M) = 0.0000
MIN HORIZ BLDG DIM (M) = 0.0000
MAX HORIZ BLDG DIM (M) = 0.0000

THE REGULATORY (DEFAULT) MIXING HEIGHT OPTION WAS SELECTED.


THE REGULATORY (DEFAULT) ANEMOMETER HEIGHT OF 10.0 METERS WAS ENTERED.

BUOY. FLUX = 28.491 M**4/S**3; MOM. FLUX = 89.866 M**4/S**2.

*** STABILITY CLASS 3 ONLY ***


*** ANEMOMETER HEIGHT WIND SPEED OF 5.00 M/S ONLY ***

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 0. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----

465
1. 0.000 3 5.0 5.6 1600.0 76.51 0.75 0.74 NO
100. 0.1275E-11 3 5.0 5.6 1600.0 76.51 13.59 9.20 NO
200. 0.3868E-02 3 5.0 5.6 1600.0 76.51 25.13 16.45 NO
300. 0.3901 3 5.0 5.6 1600.0 76.51 36.09 23.23 NO
400. 1.914 3 5.0 5.6 1600.0 76.51 46.67 29.73 NO
500. 3.426 3 5.0 5.6 1600.0 76.51 56.43 35.16 NO

ITERATION STOPPED AT 50 - MAX NOT FOUND!!!

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1. M:


788. 5.471 3 5.0 5.6 1600.0 76.51 84.19 51.06 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 0. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
570. 4.310 3 5.0 5.6 1600.0 76.41 63.22 39.00 NO
600. 4.604 3 5.0 5.6 1600.0 76.41 66.12 40.65 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 570. M:


833. 5.512 3 5.0 5.6 1600.0 76.41 88.45 53.54 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 1. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
608. 4.867 3 5.0 5.6 1600.0 75.51 66.89 41.09 NO
700. 5.429 3 5.0 5.6 1600.0 75.51 75.72 46.16 NO
800. 5.642 3 5.0 5.6 1600.0 75.51 85.23 51.67 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 608. M:


821. 5.647 3 5.0 5.6 1600.0 75.51 87.31 52.88 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 3. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
824. 5.954 3 5.0 5.6 1600.0 73.51 87.50 52.99 NO
900. 5.841 3 5.0 5.6 1600.0 73.51 94.66 57.16 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 824. M:


824. 5.954 3 5.0 5.6 1600.0 73.51 87.50 52.99 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 5. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
901. 6.103 3 5.0 5.6 1600.0 71.51 94.75 57.21 NO
1000. 5.779 3 5.0 5.6 1600.0 71.51 104.00 62.63 NO
1100. 5.395 3 5.0 5.6 1600.0 71.51 113.27 68.08 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 901. M:


901. 6.103 3 5.0 5.6 1600.0 71.51 94.75 57.21 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

466
*** TERRAIN HEIGHT OF 7. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1120. 5.475 3 5.0 5.6 1600.0 69.51 115.12 69.16 NO
1200. 5.131 3 5.0 5.6 1600.0 69.51 122.47 73.50 NO
1300. 4.719 3 5.0 5.6 1600.0 69.51 131.60 78.90 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1120. M:


1120. 5.475 3 5.0 5.6 1600.0 69.51 115.12 69.16 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 11. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1350. 4.711 3 5.0 5.6 1600.0 65.51 136.14 81.59 NO
1400. 4.504 3 5.0 5.6 1600.0 65.51 140.67 84.27 NO
1500. 4.122 3 5.0 5.6 1600.0 65.51 149.67 89.63 NO
1600. 3.780 3 5.0 5.6 1600.0 65.51 158.62 94.95 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1350. M:


1350. 4.711 3 5.0 5.6 1600.0 65.51 136.14 81.59 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 14. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1650. 3.696 3 5.0 5.6 1600.0 62.51 163.08 97.61 NO
1700. 3.541 3 5.0 5.6 1600.0 62.51 167.52 100.26 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1650. M:


1650. 3.696 3 5.0 5.6 1600.0 62.51 163.08 97.61 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 17. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1780. 3.366 3 5.0 5.6 1600.0 59.51 174.60 104.49 NO
1800. 3.310 3 5.0 5.6 1600.0 59.51 176.37 105.55 NO
1900. 3.047 3 5.0 5.6 1600.0 59.51 185.17 110.81 NO
2000. 2.814 3 5.0 5.6 1600.0 59.51 193.92 116.05 NO
2100. 2.606 3 5.0 5.6 1600.0 59.51 202.63 121.28 NO
2200. 2.419 3 5.0 5.6 1600.0 59.51 211.30 126.49 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1780. M:


1780. 3.366 3 5.0 5.6 1600.0 59.51 174.60 104.49 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 29. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
2220. 2.480 3 5.0 5.6 1600.0 47.61 213.03 127.53 NO
2300. 2.336 3 5.0 5.6 1600.0 47.61 219.93 131.68 NO
2400. 2.174 3 5.0 5.6 1600.0 47.61 228.52 136.85 NO
2500. 2.028 3 5.0 5.6 1600.0 47.61 237.07 142.00 NO

467
2600. 1.897 3 5.0 5.6 1600.0 47.61 245.59 147.14 NO
2700. 1.778 3 5.0 5.6 1600.0 47.61 254.07 152.27 NO
2800. 1.670 3 5.0 5.6 1600.0 47.61 262.52 157.38 NO
2900. 1.572 3 5.0 5.6 1600.0 47.61 270.94 162.47 NO
3000. 1.482 3 5.0 5.6 1600.0 47.61 279.33 167.56 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 2220. M:


2220. 2.480 3 5.0 5.6 1600.0 47.61 213.03 127.53 NO

DWASH= MEANS NO CALC MADE (CONC = 0.0)


DWASH=NO MEANS NO BUILDING DOWNWASH USED
DWASH=HS MEANS HUBER-SNYDER DOWNWASH USED
DWASH=SS MEANS SCHULMAN-SCIRE DOWNWASH USED
DWASH=NA MEANS DOWNWASH NOT APPLICABLE, X<3*LB

********************************************
* SUMMARY OF TERRAIN HEIGHTS ENTERED FOR *
* SIMPLE ELEVATED TERRAIN PROCEDURE *
********************************************

TERRAIN DISTANCE RANGE (M)


HT (M) MINIMUM MAXIMUM
------- -------- --------
0.0 1. 570.
0.1 570. 608.
1.0 608. 824.
3.0 824. 901.
5.0 901. 1120.
7.0 1120. 1350.
11.0 1350. 1650.
14.0 1650. 1780.
17.0 1780. 2220.
28.9 2220. 3020.

***************************************
*** SUMMARY OF SCREEN MODEL RESULTS ***
***************************************

CALCULATION MAX CONC DIST TO TERRAIN


PROCEDURE (UG/M**3) MAX (M) HT (M)
-------------- ----------- --------- -------
SIMPLE TERRAIN 6.103 901. 5.

COMPLEX TERRAIN 4.582 3090. 32. (24-HR CONC)

468
NO
08/12/13
13:07:14
*** SCREEN3 MODEL RUN ***
*** VERSION DATED 96043 ***

NO - HORNO DE HIERRO ESPONJA - OCTUBRE 2012 - MARZO 2013

COMPLEX TERRAIN INPUTS:


SOURCE TYPE = POINT
EMISSION RATE (G/S) = 1.13000
STACK HT (M) = 29.0000
STACK DIAMETER (M) = 1.6000
STACK VELOCITY (M/S) = 14.3350
STACK GAS TEMP (K) = 438.6230
AMBIENT AIR TEMP (K) = 299.7170
RECEPTOR HEIGHT (M) = 0.0000
URBAN/RURAL OPTION = RURAL

THE REGULATORY (DEFAULT) MIXING HEIGHT OPTION WAS SELECTED.


THE REGULATORY (DEFAULT) ANEMOMETER HEIGHT OF 10.0 METERS WAS ENTERED.

BUOY. FLUX = 28.491 M**4/S**3; MOM. FLUX = 89.866 M**4/S**2.

FINAL STABLE PLUME HEIGHT (M) = 84.9


DISTANCE TO FINAL RISE (M) = 153.0

*VALLEY 24-HR CALCS* **SIMPLE TERRAIN 24-HR CALCS**


TERR MAX 24-HR PLUME HT PLUME HT
HT DIST CONC CONC ABOVE STK CONC ABOVE STK U10M USTK
(M) (M) (UG/M**3) (UG/M**3) BASE (M) (UG/M**3) HGT (M) SC (M/S)
----- ------- ---------- ---------- ------ ---------- ------ -- ---- ----
29. 3020. 4.102 0.4994 84.9 4.102 62.4 6 1.0 1.8
32. 3090. 4.102 0.5809 84.9 4.102 62.4 6 1.0 1.8
34. 3250. 4.098 0.6293 84.9 4.098 62.4 6 1.0 1.8
08/12/13
13:07:14
*** SCREEN3 MODEL RUN ***
*** VERSION DATED 96043 ***

NO - HORNO DE HIERRO ESPONJA - OCTUBRE 2012 - MARZO 2013

SIMPLE TERRAIN INPUTS:


SOURCE TYPE = POINT
EMISSION RATE (G/S) = 1.13000
STACK HEIGHT (M) = 29.0000
STK INSIDE DIAM (M) = 1.6000
STK EXIT VELOCITY (M/S)= 14.3350
STK GAS EXIT TEMP (K) = 438.6230
AMBIENT AIR TEMP (K) = 299.7170
RECEPTOR HEIGHT (M) = 1.6500
URBAN/RURAL OPTION = RURAL
BUILDING HEIGHT (M) = 0.0000
MIN HORIZ BLDG DIM (M) = 0.0000
MAX HORIZ BLDG DIM (M) = 0.0000

THE REGULATORY (DEFAULT) MIXING HEIGHT OPTION WAS SELECTED.


THE REGULATORY (DEFAULT) ANEMOMETER HEIGHT OF 10.0 METERS WAS ENTERED.

BUOY. FLUX = 28.491 M**4/S**3; MOM. FLUX = 89.866 M**4/S**2.

*** STABILITY CLASS 3 ONLY ***


*** ANEMOMETER HEIGHT WIND SPEED OF 5.00 M/S ONLY ***

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 0. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1. 0.000 3 5.0 5.6 1600.0 76.51 0.75 0.74 NO

469
100. 0.1142E-11 3 5.0 5.6 1600.0 76.51 13.59 9.20 NO
200. 0.3464E-02 3 5.0 5.6 1600.0 76.51 25.13 16.45 NO
300. 0.3493 3 5.0 5.6 1600.0 76.51 36.09 23.23 NO
400. 1.714 3 5.0 5.6 1600.0 76.51 46.67 29.73 NO
500. 3.068 3 5.0 5.6 1600.0 76.51 56.43 35.16 NO

ITERATION STOPPED AT 50 - MAX NOT FOUND!!!

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1. M:


788. 4.899 3 5.0 5.6 1600.0 76.51 84.19 51.06 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 0. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
570. 3.859 3 5.0 5.6 1600.0 76.41 63.22 39.00 NO
600. 4.123 3 5.0 5.6 1600.0 76.41 66.12 40.65 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 570. M:


832. 4.935 3 5.0 5.6 1600.0 76.41 88.35 53.48 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 1. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
608. 4.358 3 5.0 5.6 1600.0 75.51 66.89 41.09 NO
700. 4.861 3 5.0 5.6 1600.0 75.51 75.72 46.16 NO
800. 5.052 3 5.0 5.6 1600.0 75.51 85.23 51.67 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 608. M:


821. 5.056 3 5.0 5.6 1600.0 75.51 87.31 52.88 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 3. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
824. 5.332 3 5.0 5.6 1600.0 73.51 87.50 52.99 NO
900. 5.230 3 5.0 5.6 1600.0 73.51 94.66 57.16 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 824. M:


824. 5.332 3 5.0 5.6 1600.0 73.51 87.50 52.99 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 5. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
901. 5.465 3 5.0 5.6 1600.0 71.51 94.75 57.21 NO
1000. 5.175 3 5.0 5.6 1600.0 71.51 104.00 62.63 NO
1100. 4.831 3 5.0 5.6 1600.0 71.51 113.27 68.08 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 901. M:


901. 5.465 3 5.0 5.6 1600.0 71.51 94.75 57.21 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************
*** TERRAIN HEIGHT OF 7. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

470
DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA
(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1120. 4.902 3 5.0 5.6 1600.0 69.51 115.12 69.16 NO
1200. 4.594 3 5.0 5.6 1600.0 69.51 122.47 73.50 NO
1300. 4.225 3 5.0 5.6 1600.0 69.51 131.60 78.90 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1120. M:


1120. 4.902 3 5.0 5.6 1600.0 69.51 115.12 69.16 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 11. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1350. 4.218 3 5.0 5.6 1600.0 65.51 136.14 81.59 NO
1400. 4.033 3 5.0 5.6 1600.0 65.51 140.67 84.27 NO
1500. 3.691 3 5.0 5.6 1600.0 65.51 149.67 89.63 NO
1600. 3.384 3 5.0 5.6 1600.0 65.51 158.62 94.95 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1350. M:


1350. 4.218 3 5.0 5.6 1600.0 65.51 136.14 81.59 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 14. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1650. 3.309 3 5.0 5.6 1600.0 62.51 163.08 97.61 NO
1700. 3.170 3 5.0 5.6 1600.0 62.51 167.52 100.26 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1650. M:


1650. 3.309 3 5.0 5.6 1600.0 62.51 163.08 97.61 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 17. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1780. 3.014 3 5.0 5.6 1600.0 59.51 174.60 104.49 NO
1800. 2.963 3 5.0 5.6 1600.0 59.51 176.37 105.55 NO
1900. 2.728 3 5.0 5.6 1600.0 59.51 185.17 110.81 NO
2000. 2.519 3 5.0 5.6 1600.0 59.51 193.92 116.05 NO
2100. 2.333 3 5.0 5.6 1600.0 59.51 202.63 121.28 NO
2200. 2.166 3 5.0 5.6 1600.0 59.51 211.30 126.49 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1780. M:


1780. 3.014 3 5.0 5.6 1600.0 59.51 174.60 104.49 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 29. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
2220. 2.220 3 5.0 5.6 1600.0 47.61 213.03 127.53 NO
2300. 2.092 3 5.0 5.6 1600.0 47.61 219.93 131.68 NO
2400. 1.947 3 5.0 5.6 1600.0 47.61 228.52 136.85 NO
2500. 1.816 3 5.0 5.6 1600.0 47.61 237.07 142.00 NO
2600. 1.698 3 5.0 5.6 1600.0 47.61 245.59 147.14 NO
2700. 1.592 3 5.0 5.6 1600.0 47.61 254.07 152.27 NO

471
2800. 1.495 3 5.0 5.6 1600.0 47.61 262.52 157.38 NO
2900. 1.407 3 5.0 5.6 1600.0 47.61 270.94 162.47 NO
3000. 1.327 3 5.0 5.6 1600.0 47.61 279.33 167.56 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 2220. M:


2220. 2.220 3 5.0 5.6 1600.0 47.61 213.03 127.53 NO

DWASH= MEANS NO CALC MADE (CONC = 0.0)


DWASH=NO MEANS NO BUILDING DOWNWASH USED
DWASH=HS MEANS HUBER-SNYDER DOWNWASH USED
DWASH=SS MEANS SCHULMAN-SCIRE DOWNWASH USED
DWASH=NA MEANS DOWNWASH NOT APPLICABLE, X<3*LB

********************************************
* SUMMARY OF TERRAIN HEIGHTS ENTERED FOR *
* SIMPLE ELEVATED TERRAIN PROCEDURE *
********************************************

TERRAIN DISTANCE RANGE (M)


HT (M) MINIMUM MAXIMUM
------- -------- --------
0. 1. 570.
0. 570. 608.
1. 608. 824.
3. 824. 901.
5. 901. 1120.
7. 1120. 1350.
11. 1350. 1650.
14. 1650. 1780.
17. 1780. 2220.
29. 2220. 3020.

***************************************
*** SUMMARY OF SCREEN MODEL RESULTS ***
***************************************

CALCULATION MAX CONC DIST TO TERRAIN


PROCEDURE (UG/M**3) MAX (M) HT (M)
-------------- ----------- ------- -------
SIMPLE TERRAIN 5.465 901. 5.

COMPLEX TERRAIN 4.102 3090. 32. (24-HR CONC)

***************************************************
** REMEMBER TO INCLUDE BACKGROUND CONCENTRATIONS **
***************************************************

472
SO2
08/12/13
18:46:12
*** SCREEN3 MODEL RUN ***
*** VERSION DATED 13043 ***

SO2 - HIERRO ESPONJA - OCTUBRE 2012 - MARZO 2013

COMPLEX TERRAIN INPUTS:


SOURCE TYPE = POINT
EMISSION RATE (G/S) = 9.53300
STACK HT (M) = 29.0000
STACK DIAMETER (M) = 1.6000
STACK VELOCITY (M/S) = 14.3350
STACK GAS TEMP (K) = 438.6230
AMBIENT AIR TEMP (K) = 299.7170
RECEPTOR HEIGHT (M) = 0.0000
URBAN/RURAL OPTION = RURAL

THE REGULATORY (DEFAULT) MIXING HEIGHT OPTION WAS SELECTED.


THE REGULATORY (DEFAULT) ANEMOMETER HEIGHT OF 10.0 METERS WAS ENTERED.

BUOY. FLUX = 28.491 M**4/S**3; MOM. FLUX = 89.866 M**4/S**2.

FINAL STABLE PLUME HEIGHT (M) = 84.9


DISTANCE TO FINAL RISE (M) = 153.0

*VALLEY 24-HR CALCS* **SIMPLE TERRAIN 24-HR CALCS**


TERR MAX 24-HR PLUME HT PLUME HT
HT DIST CONC CONC ABOVE STK CONC ABOVE STK U10M USTK
(M) (M) (UG/M**3) (UG/M**3) BASE (M) (UG/M**3) HGT (M) SC (M/S)
----- ------- ---------- ---------- ------ ---------- ------ -- ---- ----
29. 3020. 34.61 4.213 84.9 34.61 62.4 6 1.0 1.8
32. 3090. 34.61 4.900 84.9 34.61 62.4 6 1.0 1.8
34. 3250. 34.57 5.309 84.9 34.57 62.4 6 1.0 1.8
08/12/13
18:46:12
*** SCREEN3 MODEL RUN ***
*** VERSION DATED 13043 ***

SO2 - HIERRO ESPONJA - OCTUBRE 2012 - MARZO 2013

SIMPLE TERRAIN INPUTS:


SOURCE TYPE = POINT
EMISSION RATE (G/S) = 9.53300
STACK HEIGHT (M) = 29.0000
STK INSIDE DIAM (M) = 1.6000
STK EXIT VELOCITY (M/S)= 14.3350
STK GAS EXIT TEMP (K) = 438.6230
AMBIENT AIR TEMP (K) = 299.7170
RECEPTOR HEIGHT (M) = 1.6500
URBAN/RURAL OPTION = RURAL
BUILDING HEIGHT (M) = 0.0000
MIN HORIZ BLDG DIM (M) = 0.0000
MAX HORIZ BLDG DIM (M) = 0.0000

THE REGULATORY (DEFAULT) MIXING HEIGHT OPTION WAS SELECTED.


THE REGULATORY (DEFAULT) ANEMOMETER HEIGHT OF 10.0 METERS WAS ENTERED.

BUOY. FLUX = 28.491 M**4/S**3; MOM. FLUX = 89.866 M**4/S**2.

*** STABILITY CLASS 3 ONLY ***


*** ANEMOMETER HEIGHT WIND SPEED OF 5.00 M/S ONLY ***

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 0. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----

473
1. 0.000 3 5.0 5.6 1600.0 76.51 0.75 0.74 NO
100. 0.9634E-11 3 5.0 5.6 1600.0 76.51 13.59 9.20 NO
200. 0.2922E-01 3 5.0 5.6 1600.0 76.51 25.13 16.45 NO
300. 2.947 3 5.0 5.6 1600.0 76.51 36.09 23.23 NO
400. 14.46 3 5.0 5.6 1600.0 76.51 46.67 29.73 NO
500. 25.88 3 5.0 5.6 1600.0 76.51 56.43 35.16 NO

ITERATION STOPPED AT 50 - MAX NOT FOUND!!!

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1. M:


788. 41.33 3 5.0 5.6 1600.0 76.51 84.19 51.06 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 0. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
570. 32.56 3 5.0 5.6 1600.0 76.41 63.22 39.00 NO
600. 34.78 3 5.0 5.6 1600.0 76.41 66.12 40.65 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 570. M:


833. 41.64 3 5.0 5.6 1600.0 76.41 88.45 53.54 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 1. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
608. 36.77 3 5.0 5.6 1600.0 75.51 66.89 41.09 NO
700. 41.01 3 5.0 5.6 1600.0 75.51 75.72 46.16 NO
800. 42.62 3 5.0 5.6 1600.0 75.51 85.23 51.67 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 608. M:


821. 42.66 3 5.0 5.6 1600.0 75.51 87.31 52.88 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 3. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
824. 44.98 3 5.0 5.6 1600.0 73.51 87.50 52.99 NO
900. 44.12 3 5.0 5.6 1600.0 73.51 94.66 57.16 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 824. M:


824. 44.98 3 5.0 5.6 1600.0 73.51 87.50 52.99 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 5. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
901. 46.10 3 5.0 5.6 1600.0 71.51 94.75 57.21 NO
1000. 43.66 3 5.0 5.6 1600.0 71.51 104.00 62.63 NO
1100. 40.76 3 5.0 5.6 1600.0 71.51 113.27 68.08 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 901. M:


901. 46.10 3 5.0 5.6 1600.0 71.51 94.75 57.21 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

474
*** TERRAIN HEIGHT OF 7. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1120. 41.36 3 5.0 5.6 1600.0 69.51 115.12 69.16 NO
1200. 38.76 3 5.0 5.6 1600.0 69.51 122.47 73.50 NO
1300. 35.65 3 5.0 5.6 1600.0 69.51 131.60 78.90 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1120. M:


1120. 41.36 3 5.0 5.6 1600.0 69.51 115.12 69.16 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 11. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1350. 35.58 3 5.0 5.6 1600.0 65.51 136.14 81.59 NO
1400. 34.02 3 5.0 5.6 1600.0 65.51 140.67 84.27 NO
1500. 31.14 3 5.0 5.6 1600.0 65.51 149.67 89.63 NO
1600. 28.55 3 5.0 5.6 1600.0 65.51 158.62 94.95 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1350. M:


1350. 35.58 3 5.0 5.6 1600.0 65.51 136.14 81.59 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 14. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1650. 27.92 3 5.0 5.6 1600.0 62.51 163.08 97.61 NO
1700. 26.74 3 5.0 5.6 1600.0 62.51 167.52 100.26 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1650. M:


1650. 27.92 3 5.0 5.6 1600.0 62.51 163.08 97.61 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 17. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
1780. 25.43 3 5.0 5.6 1600.0 59.51 174.60 104.49 NO
1800. 25.00 3 5.0 5.6 1600.0 59.51 176.37 105.55 NO
1900. 23.02 3 5.0 5.6 1600.0 59.51 185.17 110.81 NO
2000. 21.26 3 5.0 5.6 1600.0 59.51 193.92 116.05 NO
2100. 19.68 3 5.0 5.6 1600.0 59.51 202.63 121.28 NO
2200. 18.27 3 5.0 5.6 1600.0 59.51 211.30 126.49 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 1780. M:


1780. 25.43 3 5.0 5.6 1600.0 59.51 174.60 104.49 NO

**********************************
*** SCREEN AUTOMATED DISTANCES ***
**********************************

*** TERRAIN HEIGHT OF 29. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
2220. 18.73 3 5.0 5.6 1600.0 47.61 213.03 127.53 NO
2300. 17.65 3 5.0 5.6 1600.0 47.61 219.93 131.68 NO
2400. 16.42 3 5.0 5.6 1600.0 47.61 228.52 136.85 NO
2500. 15.32 3 5.0 5.6 1600.0 47.61 237.07 142.00 NO

475
2600. 14.33 3 5.0 5.6 1600.0 47.61 245.59 147.14 NO
2700. 13.43 3 5.0 5.6 1600.0 47.61 254.07 152.27 NO
2800. 12.61 3 5.0 5.6 1600.0 47.61 262.52 157.38 NO
2900. 11.87 3 5.0 5.6 1600.0 47.61 270.94 162.47 NO
3000. 11.20 3 5.0 5.6 1600.0 47.61 279.33 167.56 NO

MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 2220. M:


2220. 18.73 3 5.0 5.6 1600.0 47.61 213.03 127.53 NO

DWASH= MEANS NO CALC MADE (CONC = 0.0)


DWASH=NO MEANS NO BUILDING DOWNWASH USED
DWASH=HS MEANS HUBER-SNYDER DOWNWASH USED
DWASH=SS MEANS SCHULMAN-SCIRE DOWNWASH USED
DWASH=NA MEANS DOWNWASH NOT APPLICABLE, X<3*LB

********************************************
* SUMMARY OF TERRAIN HEIGHTS ENTERED FOR *
* SIMPLE ELEVATED TERRAIN PROCEDURE *
********************************************

TERRAIN DISTANCE RANGE (M)


HT (M) MINIMUM MAXIMUM
------- -------- --------
0.0 1. 570.
0.1 570. 608.
1.0 608. 824.
3.0 824. 901.
5.0 901. 1120.
7.0 1120. 1350.
11.0 1350. 1650.
14.0 1650. 1780.
17.0 1780. 2220.
28.9 2220. 3020.

***************************************
*** SUMMARY OF SCREEN MODEL RESULTS ***
***************************************

CALCULATION MAX CONC DIST TO TERRAIN


PROCEDURE (UG/M**3) MAX (M) HT (M)
-------------- ----------- --------- -------
SIMPLE TERRAIN 46.10 901. 5.

COMPLEX TERRAIN 34.61 3090. 32. (24-HR CONC)

476
INFORME DE MODELACIN DE EMISIONES
ATMOSFRICA

477
Datos Meteorolgicos - Octubre 2012

Velocidad Presin Direccin del


Fecha de Hora de Temperatura Humedad (%
del Viento Atmosfrica Viento (viene
muestreo muestreo (C) HR)
(m/s) (mbar) de)

03/10/2012 2:00 PM 21.80 60.00 0.90 1015.00 NW


03/10/2012 3:00 PM 21.80 59.00 1.80 1014.90 NW
03/10/2012 4:00 PM 21.80 59.00 1.30 1015.10 NNW
03/10/2012 5:00 PM 20.60 65.00 0.90 1015.50 NW
03/10/2012 6:00 PM 19.80 67.00 0.40 1015.90 NW
03/10/2012 7:00 PM 18.80 72.00 0.00 1016.60 NNW
03/10/2012 8:00 PM 18.20 75.00 0.00 1017.00 NNW
03/10/2012 9:00 PM 17.20 79.00 0.00 1017.30 WNW
03/10/2012 10:00 PM 17.30 78.00 0.00 1017.20 NW
03/10/2012 11:00 PM 16.80 78.00 0.00 1016.70 W
04/10/2012 12:00 AM 16.20 77.00 0.00 1016.20 NW
04/10/2012 1:00 AM 16.10 79.00 0.00 1015.50 W
04/10/2012 2:00 AM 15.80 80.00 0.00 1015.20 S
04/10/2012 3:00 AM 14.70 81.00 0.00 1014.60 W
04/10/2012 4:00 AM 14.60 81.00 0.00 1014.70 W
04/10/2012 5:00 AM 15.20 82.00 0.00 1015.40 WNW
04/10/2012 6:00 AM 15.10 83.00 0.00 1016.20 WNW
04/10/2012 7:00 AM 16.30 84.00 0.00 1017.00 NW
04/10/2012 8:00 AM 18.20 76.00 0.90 1017.40 NW
04/10/2012 9:00 AM 20.00 68.00 1.30 1017.50 W
04/10/2012 10:00 AM 22.90 59.00 1.30 1017.10 W
04/10/2012 11:00 AM 24.90 55.00 1.80 1016.60 W
04/10/2012 12:00 PM 23.80 59.00 3.10 1016.00 S
04/10/2012 1:00 PM 24.20 56.00 3.10 1015.40 S
04/10/2012 2:00 PM 24.80 53.00 3.60 1014.80 SSW
04/10/2012 3:00 PM 26.30 47.00 2.20 1014.40 SSW
04/10/2012 4:00 PM 26.10 47.00 2.20 1014.20 SSW
04/10/2012 5:00 PM 24.30 52.00 2.20 1014.20 SSW
04/10/2012 6:00 PM 22.60 58.00 2.20 1015.00 SSW
04/10/2012 7:00 PM 20.70 65.00 1.30 1015.80 SSW
04/10/2012 8:00 PM 20.20 67.00 0.90 1016.30 SSW
04/10/2012 9:00 PM 18.90 71.00 1.30 1016.80 SW
04/10/2012 10:00 PM 18.70 75.00 0.90 1016.80 SW
04/10/2012 11:00 PM 18.20 77.00 1.80 1016.60 W
05/10/2012 12:00 AM 17.70 78.00 1.30 1016.70 W
05/10/2012 1:00 AM 17.20 81.00 0.00 1016.30 SW
05/10/2012 2:00 AM 17.20 82.00 0.00 1015.90 SW
05/10/2012 3:00 AM 17.20 81.00 0.00 1015.90 SSW
05/10/2012 4:00 AM 17.20 82.00 0.00 1015.80 WNW

478
05/10/2012 5:00 AM 16.90 84.00 0.00 1016.00 NNW
05/10/2012 6:00 AM 16.70 85.00 0.00 1016.20 NW
05/10/2012 7:00 AM 16.70 88.00 0.00 1016.50 W
05/10/2012 8:00 AM 16.90 88.00 0.00 1017.00 SW
05/10/2012 9:00 AM 17.20 88.00 0.00 1017.30 SW
05/10/2012 10:00 AM 17.40 85.00 0.00 1017.20 WSW
05/10/2012 11:00 AM 18.40 78.00 0.00 1016.70 WSW
05/10/2012 12:00 PM 19.20 72.00 0.90 1016.00 W
05/10/2012 1:00 PM 19.60 69.00 1.30 1015.40 WSW
05/10/2012 2:00 PM 20.70 64.00 1.80 1014.70 WSW
05/10/2012 3:00 PM 21.40 59.00 1.80 1014.50 NNW
05/10/2012 4:00 PM 21.30 58.00 2.20 1014.30 NW
05/10/2012 5:00 PM 20.70 60.00 1.30 1014.30 NNW
05/10/2012 6:00 PM 19.40 63.00 0.90 1014.80 SW
05/10/2012 7:00 PM 17.80 70.00 0.90 1015.70 SW
05/10/2012 8:00 PM 17.20 74.00 0.00 1015.80 WSW
05/10/2012 9:00 PM 16.70 76.00 0.40 1015.90 WSW
05/10/2012 10:00 PM 16.60 77.00 0.00 1015.90 WSW
05/10/2012 11:00 PM 15.20 77.00 0.00 1015.40 SW
06/10/2012 12:00 AM 14.60 79.00 0.00 1014.60 WSW
06/10/2012 1:00 AM 14.20 78.00 0.00 1014.20 WSW
06/10/2012 2:00 AM 13.80 78.00 0.00 1013.80 SW
06/10/2012 3:00 AM 13.80 80.00 0.00 1013.80 SW
06/10/2012 4:00 AM 14.30 80.00 0.00 1013.70 WSW
06/10/2012 5:00 AM 15.10 82.00 0.00 1013.90 SW
06/10/2012 6:00 AM 15.10 82.00 0.00 1014.60 SW
06/10/2012 7:00 AM 16.80 78.00 1.30 1015.20 WNW
06/10/2012 8:00 AM 19.00 69.00 2.20 1015.20 E
06/10/2012 9:00 AM 20.90 62.00 1.80 1015.00 E
06/10/2012 10:00 AM 22.70 53.00 0.40 1014.70 WSW
06/10/2012 11:00 AM 23.00 55.00 1.30 1014.10 WSW
06/10/2012 12:00 PM 23.80 59.00 3.10 1016.00 S
06/10/2012 1:00 PM 24.20 56.00 3.10 1015.40 S
MAXIMO 26.30 88.00 3.60 1017.50
MINIMO 13.80 47.00 0.00 1013.70 SW
PROMEDIO 18.84 71.31 0.85 1015.63

479
Datos Meteorolgicos - Noviembre 2012

Velocidad Presin Direccin del


Fecha de Hora de Temperatura Humedad (%
del Viento Atmosfrica Viento (viene
muestreo muestreo (C) HR)
(m/s) (mbar) de)

08/11/2012 07:00 18.80 79.00 0.40 1014.60 SSW


08/11/2012 08:00 21.10 71.00 0.40 1014.80 SSW
08/11/2012 09:00 21.90 67.00 1.30 1015.00 SSW
08/11/2012 10:00 23.60 61.00 1.80 1014.60 SSW
08/11/2012 11:00 24.80 57.00 1.80 1014.40 W
08/11/2012 12:00 25.40 54.00 2.20 1013.80 W
08/11/2012 13:00 26.30 50.00 1.80 1012.80 SW
08/11/2012 14:00 26.80 50.00 1.80 1012.30 SW
08/11/2012 15:00 25.60 54.00 2.20 1012.10 SW
08/11/2012 16:00 24.90 56.00 1.80 1011.90 SSW
08/11/2012 17:00 24.20 58.00 1.30 1012.10 SSW
08/11/2012 18:00 21.80 65.00 1.80 1012.60 SSW
08/11/2012 19:00 19.90 72.00 1.30 1013.60 SW
08/11/2012 20:00 19.30 74.00 1.30 1014.40 W
08/11/2012 21:00 19.70 71.00 0.40 1014.80 W
08/11/2012 22:00 19.40 72.00 0.00 1014.60 SW
08/11/2012 23:00 18.60 76.00 0.90 1014.00 SSW
09/11/2012 00:00 18.30 79.00 0.90 1013.40 W
09/11/2012 01:00 18.30 77.00 0.00 1012.60 SSW
09/11/2012 02:00 17.90 76.00 0.00 1012.10 SW
09/11/2012 03:00 17.20 77.00 0.00 1011.90 SW
09/11/2012 04:00 16.90 79.00 0.00 1012.10 SSW
09/11/2012 05:00 16.60 79.00 0.00 1012.60 SSW
09/11/2012 06:00 16.60 81.00 0.00 1013.30 SSW
09/11/2012 07:00 19.90 76.00 0.90 1013.40 SW
09/11/2012 08:00 21.70 65.00 0.40 1013.40 W
09/11/2012 09:00 22.70 63.00 0.90 1013.30 W
09/11/2012 10:00 23.30 61.00 1.80 1013.30 W
09/11/2012 11:00 23.60 60.00 2.70 1013.10 SSW
09/11/2012 12:00 24.20 58.00 2.70 1012.30 W
09/11/2012 13:00 23.90 59.00 3.10 1011.70 W
09/11/2012 14:00 24.10 59.00 3.10 1011.20 SW
09/11/2012 15:00 24.20 59.00 3.10 1010.70 SW
09/11/2012 16:00 23.40 61.00 2.70 1010.60 S
09/11/2012 17:00 23.00 63.00 1.80 1011.00 S
09/11/2012 18:00 21.70 67.00 1.80 1011.50 S
09/11/2012 19:00 21.30 69.00 0.90 1012.00 SSW
09/11/2012 20:00 20.70 72.00 0.90 1012.50 SSW
09/11/2012 21:00 20.40 71.00 1.80 1012.90 SSW
09/11/2012 22:00 20.30 71.00 2.20 1013.20 SSW

480
09/11/2012 23:00 19.90 73.00 1.80 1013.10 W
10/11/2012 00:00 19.70 74.00 0.90 1012.80 W
10/11/2012 01:00 19.10 77.00 0.40 1012.20 SW
10/11/2012 02:00 19.20 77.00 0.40 1011.40 SW
10/11/2012 03:00 19.30 77.00 0.40 1011.20 SW
10/11/2012 04:00 19.20 78.00 0.40 1011.10 SW
10/11/2012 05:00 19.20 78.00 0.40 1011.40 SSW
10/11/2012 06:00 19.30 78.00 0.40 1012.20 SSW
MAXIMO 26.80 81.00 3.10 1015.00
MINIMO 16.60 50.00 0.00 1010.60 SSW
PROMEDIO 21.19 68.35 1.24 1012.75

481
Datos Meteorolgicos - Diciembre 2012

Velocidad Presin Direccin del


Fecha de Hora de Temperatura Humedad (%
del Viento Atmosfrica Viento (viene
muestreo muestreo (C) HR)
(m/s) (mbar) de)

12/12/2012 14:00 25.80 58.00 2.40 1012.60 SW


12/12/2012 15:00 25.70 60.00 2.60 1012.10 SW
12/12/2012 16:00 24.80 63.00 2.20 1011.80 S
12/12/2012 17:00 24.50 64.00 1.80 1011.60 SW
12/12/2012 18:00 23.80 66.00 1.80 1011.70 SSW
12/12/2012 19:00 21.90 73.00 1.20 1012.60 SW
12/12/2012 20:00 20.20 80.00 1.20 1013.20 W
12/12/2012 21:00 20.10 80.00 0.40 1013.90 W
12/12/2012 22:00 20.20 80.00 0.00 1014.40 SW
12/12/2012 23:00 20.30 81.00 0.40 1014.50 SSW
13/12/2012 00:00 19.70 83.00 0.90 1014.30 W
13/12/2012 01:00 19.40 85.00 0.00 1013.90 SSW
13/12/2012 02:00 19.40 86.00 0.00 1013.80 SW
13/12/2012 03:00 19.60 85.00 0.00 1013.50 SW
13/12/2012 04:00 19.40 85.00 0.00 1013.80 SW
13/12/2012 05:00 19.50 84.00 0.00 1014.20 SSW
13/12/2012 06:00 19.70 84.00 0.00 1014.80 SSW
13/12/2012 07:00 20.10 81.00 0.40 1015.50 SSW
13/12/2012 08:00 20.80 78.00 0.40 1015.90 SSW
13/12/2012 09:00 22.40 74.00 1.20 1015.80 SSW
13/12/2012 10:00 24.60 67.00 1.60 1015.20 SW
13/12/2012 11:00 25.80 61.00 1.80 1014.70 W
13/12/2012 12:00 25.90 60.00 2.20 1014.40 W
13/12/2012 13:00 26.10 58.00 1.80 1014.00 SW
13/12/2012 14:00 26.20 59.00 3.00 1013.30 SSW
13/12/2012 15:00 28.20 52.00 3.10 1012.60 SW
13/12/2012 16:00 27.30 54.00 2.80 1012.90 S
13/12/2012 17:00 27.00 55.00 1.60 1013.00 S
13/12/2012 18:00 24.60 63.00 1.60 1013.30 SW
13/12/2012 19:00 22.40 71.00 0.90 1013.90 SSW
13/12/2012 20:00 21.40 77.00 0.90 1014.60 SSW
13/12/2012 21:00 21.10 78.00 1.80 1015.20 SSW
13/12/2012 22:00 20.60 80.00 2.20 1015.70 SSW
13/12/2012 23:00 20.40 81.00 1.80 1015.50 W
14/12/2012 00:00 20.00 83.00 0.90 1015.10 W
14/12/2012 01:00 20.10 83.00 0.00 1014.90 SW
14/12/2012 02:00 20.30 83.00 0.00 1014.40 SW
14/12/2012 03:00 20.30 82.00 0.00 1014.10 SW
14/12/2012 04:00 20.30 83.00 0.00 1013.90 SW
14/12/2012 05:00 20.40 83.00 0.40 1013.90 SSW

482
14/12/2012 06:00 20.70 82.00 0.00 1014.50 SSW
14/12/2012 07:00 20.70 81.00 0.40 1014.90 SW
14/12/2012 08:00 21.20 78.00 0.90 1015.30 W
14/12/2012 09:00 22.70 72.00 0.90 1015.10 W
14/12/2012 10:00 24.80 66.00 1.80 1014.50 SW
14/12/2012 11:00 25.60 62.00 2.70 1013.90 SSW
14/12/2012 12:00 26.20 59.00 2.70 1013.10 SW
14/12/2012 13:00 28.40 52.00 3.10 1012.40 W
14/12/2012 14:00 27.10 58.00 2.90 1013.40 SSW
14/12/2012 15:00 26.80 52.00 3.20 1012.70 S
14/12/2012 16:00 26.70 55.00 2.90 1012.90 S
14/12/2012 17:00 26.40 56.00 1.80 1013.00 S
14/12/2012 18:00 24.80 62.00 1.60 1013.40 SW
14/12/2012 19:00 22.50 73.00 0.80 1013.90 SW
14/12/2012 20:00 21.60 78.00 0.80 1014.60 SSW
14/12/2012 21:00 21.10 79.00 2.00 1015.20 SSW
14/12/2012 22:00 20.20 81.00 2.40 1015.70 SSW
14/12/2012 23:00 19.90 82.00 1.90 1015.50 SSE
15/12/2012 00:00 19.70 84.00 1.00 1015.20 SE
15/12/2012 01:00 19.60 84.00 0.80 1014.90 SE
15/12/2012 02:00 19.70 82.00 0.00 1014.40 S
15/12/2012 03:00 19.90 81.00 0.00 1014.10 S
15/12/2012 04:00 20.10 82.00 0.00 1013.90 SW
15/12/2012 05:00 20.20 84.00 0.50 1013.90 SSW
15/12/2012 06:00 20.70 81.00 0.00 1014.50 SSW
15/12/2012 07:00 20.80 80.00 0.30 1014.90 SW
15/12/2012 08:00 21.10 77.00 1.00 1015.30 W
15/12/2012 09:00 21.50 73.00 1.20 1015.10 SE
15/12/2012 10:00 23.70 67.00 2.00 1014.50 SW
15/12/2012 11:00 25.40 63.00 2.60 1013.90 SSW
15/12/2012 12:00 26.30 58.00 2.80 1013.20 SW
15/12/2012 13:00 26.70 51.00 3.20 1012.60 SSW
MAXIMO 28.40 86.00 3.20 1015.90
MINIMO 19.40 51.00 0.00 1011.60 SW
PROMEDIO 22.54 72.47 1.30 1014.07

483
Datos Meteorolgicos Enero 2013

Velocidad Presin Direccin del


Fecha de Hora de Temperatura Humedad (%
del Viento Atmosfrica Viento (viene
muestreo muestreo (C) HR)
(m/s) (mbar) de)

09/01/2013 16:00 29.10 52.00 0.00 998.20 WNW


09/01/2013 17:00 28.70 52.00 1.80 998.50 WSW
09/01/2013 18:00 26.40 60.00 1.80 999.20 WSW
09/01/2013 19:00 24.90 65.00 1.30 1000.10 W
09/01/2013 20:00 22.90 73.00 0.40 1001.00 WSW
09/01/2013 21:00 21.90 77.00 0.90 1001.60 WSW
09/01/2013 22:00 21.40 78.00 0.40 1002.00 NNE
09/01/2013 23:00 21.40 78.00 0.40 1001.70 NNE
10/01/2013 00:00 21.00 79.00 0.00 1001.20 N
10/01/2013 01:00 20.80 82.00 0.40 1000.60 NNW
10/01/2013 02:00 20.50 84.00 0.40 1000.60 NNE
10/01/2013 03:00 20.20 87.00 1.30 1000.60 NNE
10/01/2013 04:00 19.80 88.00 0.90 1000.70 NNE
10/01/2013 05:00 19.80 89.00 0.40 1001.30 NE
10/01/2013 06:00 19.80 89.00 0.40 1001.80 NNE
10/01/2013 07:00 20.30 88.00 0.40 1002.30 NE
10/01/2013 08:00 21.90 81.00 0.00 1002.50 NNE
10/01/2013 09:00 22.60 79.00 0.40 1002.90 NNW
10/01/2013 10:00 24.20 74.00 0.90 1002.70 NW
10/01/2013 11:00 24.60 71.00 1.30 1002.20 NW
10/01/2013 12:00 24.40 71.00 1.80 1001.80 NW
10/01/2013 13:00 26.20 66.00 2.20 1001.40 NW
10/01/2013 14:00 27.90 58.00 2.20 1000.70 NNW
10/01/2013 15:00 27.80 60.00 2.20 1000.30 NW
10/01/2013 16:00 28.80 53.00 2.20 999.70 NW
10/01/2013 17:00 27.30 58.00 1.80 1000.10 NW
10/01/2013 18:00 25.60 64.00 1.80 1000.40 NW
10/01/2013 19:00 23.30 73.00 0.90 1001.40 WSW
10/01/2013 20:00 21.40 80.00 0.90 1001.80 NW
10/01/2013 21:00 21.20 81.00 0.40 1001.90 NW
10/01/2013 22:00 21.20 82.00 0.40 1001.90 NE
10/01/2013 23:00 20.90 83.00 0.40 1001.50 NNE
11/01/2013 00:00 20.70 86.00 0.40 1000.90 NNE
11/01/2013 01:00 20.70 86.00 0.40 1000.60 NNE
11/01/2013 02:00 20.30 89.00 0.90 1000.50 NNE
11/01/2013 03:00 20.20 89.00 0.90 1000.60 NE
11/01/2013 04:00 19.70 91.00 1.30 1000.70 NE
11/01/2013 05:00 20.00 90.00 1.30 1000.90 NE
11/01/2013 06:00 20.00 90.00 0.90 1001.20 NNE
11/01/2013 07:00 20.20 89.00 0.40 1001.60 NNE

484
11/01/2013 08:00 21.20 85.00 0.00 1001.70 SSW
11/01/2013 09:00 22.70 80.00 0.40 1001.10 NE
11/01/2013 10:00 24.80 71.00 0.90 1000.80 NW
11/01/2013 11:00 26.30 66.00 1.80 1000.00 NNW
11/01/2013 12:00 26.70 66.00 2.20 999.80 NW
11/01/2013 13:00 26.90 63.00 2.70 999.70 NW
11/01/2013 14:00 27.40 60.00 2.20 999.20 NNW
11/01/2013 15:00 28.50 56.00 2.20 998.30 NW
MAXIMO 29.10 91.00 2.70 1002.90
MINIMO 19.70 52.00 0.00 998.20 NW
PROMEDIO 23.22 75.25 1.04 1000.88

485
Datos Meteorolgicos Febrero 2013

Velocidad Presin Direccin del


Fecha de Hora de Temperatura Humedad (%
del Viento Atmosfrica Viento (viene
muestreo muestreo (C) HR)
(m/s) (mbar) de)

05/02/2013 03:00 p.m. 27.10 60.00 0.40 1002.90 NE


05/02/2013 04:00 p.m. 26.20 61.00 0.90 1003.10 NNW
05/02/2013 05:00 p.m. 26.10 60.00 0.90 1003.00 NNW
05/02/2013 06:00 p.m. 25.30 63.00 1.30 1003.30 NW
05/02/2013 07:00 p.m. 24.30 69.00 1.30 1003.70 NW
05/02/2013 08:00 p.m. 23.20 76.00 0.90 1004.20 NNW
05/02/2013 09:00 p.m. 23.10 76.00 0.00 1004.70 NW
05/02/2013 10:00 p.m. 22.30 81.00 0.00 1004.90 NNW
05/02/2013 11:00 p.m. 22.10 81.00 0.00 1004.70 NNW
06/02/2013 12:00 a.m. 21.80 85.00 0.00 1004.40 NNW
06/02/2013 01:00 a.m. 21.90 84.00 0.00 1003.90 NNW
06/02/2013 02:00 a.m. 22.10 86.00 0.00 1003.20 NE
06/02/2013 03:00 a.m. 22.00 87.00 0.00 1002.70 W
06/02/2013 04:00 a.m. 21.80 87.00 0.00 1002.70 WSW
06/02/2013 05:00 a.m. 21.40 89.00 0.00 1003.10 SSW
06/02/2013 06:00 a.m. 21.60 89.00 0.00 1003.60 SSW
06/02/2013 07:00 a.m. 21.80 90.00 0.00 1004.20 SE
06/02/2013 08:00 a.m. 22.60 87.00 0.00 1004.70 SE
06/02/2013 09:00 a.m. 23.30 81.00 0.00 1004.90 SE
06/02/2013 10:00 a.m. 23.50 86.00 0.00 1004.60 SE
06/02/2013 11:00 a.m. 24.60 77.00 0.00 1003.90 NE
06/02/2013 12:00 p.m. 27.40 65.00 0.40 1003.30 NNW
06/02/2013 01:00 p.m. 29.20 55.00 1.30 1002.50 NNW
06/02/2013 02:00 p.m. 30.60 47.00 2.20 1001.70 NNW
06/02/2013 03:00 p.m. 29.90 47.00 2.70 1001.20 NNW
06/02/2013 04:00 p.m. 28.80 49.00 3.60 1000.60 NW
06/02/2013 05:00 p.m. 27.80 51.00 3.60 1000.60 NW
06/02/2013 06:00 p.m. 26.30 59.00 3.10 1001.00 NW
06/02/2013 07:00 p.m. 24.40 68.00 1.80 1001.40 NW
06/02/2013 08:00 p.m. 23.20 75.00 0.40 1002.10 NNW
06/02/2013 09:00 p.m. 22.80 78.00 0.00 1002.50 NNW
06/02/2013 10:00 p.m. 22.20 79.00 0.00 1002.80 NW
06/02/2013 11:00 p.m. 21.80 80.00 0.00 1002.50 ---
07/02/2013 12:00 a.m. 21.30 81.00 0.00 1002.10 NW
07/02/2013 01:00 a.m. 21.90 81.00 0.00 1001.60 SSE
07/02/2013 02:00 a.m. 21.60 85.00 0.00 1001.10 SSE
07/02/2013 03:00 a.m. 20.80 85.00 0.00 1000.60 SSE
07/02/2013 04:00 a.m. 20.20 85.00 0.00 1000.50 SSW
07/02/2013 05:00 a.m. 20.60 83.00 0.00 1000.80 SW
07/02/2013 06:00 a.m. 20.70 83.00 0.00 1000.90 SW

486
07/02/2013 07:00 a.m. 23.40 76.00 0.00 1001.50 NW
07/02/2013 08:00 a.m. 24.80 70.00 0.40 1002.00 NNW
07/02/2013 09:00 a.m. 27.10 61.00 0.40 1002.50 NNW
07/02/2013 10:00 a.m. 28.80 56.00 0.90 1002.30 NE
07/02/2013 11:00 a.m. 29.40 50.00 1.30 1002.00 NE
07/02/2013 12:00 p.m. 30.40 47.00 1.80 1001.20 NE
07/02/2013 01:00 p.m. 30.50 51.00 2.20 1000.70 NE
07/02/2013 02:00 p.m. 30.10 52.00 2.20 1000.00 NNW
07/02/2013 03:00 p.m. 29.70 51.00 3.60 999.50 NW
07/02/2013 04:00 p.m. 29.60 51.00 3.60 999.20 NW
07/02/2013 05:00 p.m. 28.90 53.00 3.10 999.40 NW
07/02/2013 06:00 p.m. 27.80 57.00 2.70 1000.00 NW
07/02/2013 07:00 p.m. 26.20 67.00 2.20 1000.60 NW
07/02/2013 08:00 p.m. 25.40 70.00 1.80 1001.10 W
07/02/2013 09:00 p.m. 24.40 76.00 0.40 1001.50 NW
07/02/2013 10:00 p.m. 23.50 78.00 0.40 1001.60 NW
07/02/2013 11:00 p.m. 23.30 79.00 0.40 1001.90 NW
08/02/2013 12:00 a.m. 22.50 82.00 0.40 1001.80 NW
08/02/2013 01:00 a.m. 22.00 83.00 0.00 1001.40 NW
08/02/2013 02:00 a.m. 22.70 83.00 0.00 1000.90 E
08/02/2013 03:00 a.m. 22.80 84.00 0.40 1000.90 E
08/02/2013 04:00 a.m. 22.20 88.00 0.90 1001.10 E
08/02/2013 05:00 a.m. 21.90 87.00 0.00 1001.30 E
08/02/2013 06:00 a.m. 21.60 88.00 0.00 1001.80 E
08/02/2013 07:00 a.m. 22.60 84.00 0.00 1002.30 E
08/02/2013 08:00 a.m. 25.20 77.00 0.40 1002.70 SW
08/02/2013 09:00 a.m. 27.60 66.00 0.40 1002.70 NW
08/02/2013 10:00 a.m. 29.00 60.00 0.40 1002.60 ENE
08/02/2013 11:00 a.m. 29.70 56.00 1.30 1002.40 NE
08/02/2013 12:00 p.m. 29.70 54.00 1.80 1002.00 NE
08/02/2013 01:00 p.m. 29.90 51.00 1.30 1001.50 NE
08/02/2013 02:00 p.m. 30.20 51.00 1.30 1001.00 NE
MAXIMO 30.60 90.00 3.60 1004.90
MINIMO 20.20 47.00 0.00 999.20 NW
PROMEDIO 24.90 71.25 0.84 1002.13

487
Datos Meteorolgicos Marzo 2013

Velocidad Presin Direccin del


Fecha de Hora de Temperatura Humedad (%
del Viento Atmosfrica Viento (viene
muestreo muestreo (C) HR)
(m/s) (mbar) de)

05/03/2013 02:00 p.m. 31.30 49.00 1.30 1002.10 NNW


05/03/2013 03:00 p.m. 31.90 47.00 1.30 1001.70 NW
05/03/2013 04:00 p.m. 30.90 49.00 1.30 1001.30 W
05/03/2013 05:00 p.m. 30.10 52.00 2.70 1001.70 NW
05/03/2013 06:00 p.m. 26.90 61.00 3.10 1002.20 NW
05/03/2013 07:00 p.m. 24.20 72.00 2.20 1002.90 WSW
05/03/2013 08:00 p.m. 23.90 73.00 0.90 1003.40 NW
05/03/2013 09:00 p.m. 22.50 78.00 0.00 1004.00 W
05/03/2013 10:00 p.m. 22.40 78.00 0.00 1004.00 W
05/03/2013 11:00 p.m. 22.60 78.00 0.00 1004.00 NNW
06/03/2013 12:00 a.m. 22.30 80.00 0.00 1003.50 NNW
06/03/2013 01:00 a.m. 22.20 82.00 0.00 1002.70 NNW
06/03/2013 02:00 a.m. 22.10 83.00 0.00 1002.10 WNW
06/03/2013 03:00 a.m. 22.10 84.00 0.00 1001.80 WNW
06/03/2013 04:00 a.m. 22.10 85.00 0.00 1001.60 WNW
06/03/2013 05:00 a.m. 21.20 83.00 0.00 1001.80 WNW
06/03/2013 06:00 a.m. 21.20 84.00 0.00 1002.20 WNW
06/03/2013 07:00 a.m. 22.10 82.00 0.00 1002.90 NNW
06/03/2013 08:00 a.m. 23.60 82.00 0.00 1003.40 NNW
06/03/2013 09:00 a.m. 25.90 74.00 0.40 1003.70 NW
06/03/2013 10:00 a.m. 28.80 65.00 0.40 1003.30 NW
06/03/2013 11:00 a.m. 28.30 63.00 0.90 1003.30 NW
06/03/2013 12:00 p.m. 30.40 54.00 0.90 1002.30 NW
06/03/2013 01:00 p.m. 31.10 51.00 0.90 1001.40 NW
06/03/2013 02:00 p.m. 31.90 47.00 1.30 1000.70 NW
06/03/2013 03:00 p.m. 30.30 49.00 1.30 1000.20 NW
06/03/2013 04:00 p.m. 29.30 53.00 3.10 1000.00 WNW
06/03/2013 05:00 p.m. 28.80 54.00 3.10 1000.50 WNW
06/03/2013 06:00 p.m. 26.20 66.00 2.70 1001.30 WSW
06/03/2013 07:00 p.m. 24.20 74.00 0.90 1002.30 W
06/03/2013 08:00 p.m. 22.60 81.00 1.30 1003.60 WNW
06/03/2013 09:00 p.m. 22.30 82.00 0.40 1004.50 NW
06/03/2013 10:00 p.m. 21.90 83.00 0.40 1005.10 NNW
06/03/2013 11:00 p.m. 22.10 82.00 0.00 1005.00 WSW
07/03/2013 12:00 a.m. 22.90 79.00 0.00 1004.50 ENE
07/03/2013 01:00 a.m. 23.60 80.00 0.00 1003.50 NNE
07/03/2013 02:00 a.m. 23.90 81.00 0.00 1002.70 NNE
07/03/2013 03:00 a.m. 22.90 79.00 0.00 1002.50 NW
07/03/2013 04:00 a.m. 22.70 81.00 0.00 1002.30 NNW
07/03/2013 05:00 a.m. 22.40 82.00 0.00 1002.60 NNW

488
07/03/2013 06:00 a.m. 22.60 84.00 0.00 1002.80 NW
07/03/2013 07:00 a.m. 23.30 84.00 0.00 1003.20 WNW
07/03/2013 08:00 a.m. 25.30 76.00 0.40 1004.00 NNW
07/03/2013 09:00 a.m. 27.10 69.00 0.40 1003.90 NW
07/03/2013 10:00 a.m. 27.70 67.00 0.90 1003.80 NNW
07/03/2013 11:00 a.m. 28.30 58.00 0.90 1003.60 NW
07/03/2013 12:00 p.m. 29.10 54.00 1.30 1003.40 NW
07/03/2013 01:00 p.m. 30.40 49.00 0.90 1003.10 NNW
07/03/2013 02:00 p.m. 29.60 54.00 1.30 1001.40 NW
07/03/2013 03:00 p.m. 28.80 57.00 1.30 1001.10 NW
07/03/2013 04:00 p.m. 28.60 58.00 0.90 1000.70 NW
07/03/2013 05:00 p.m. 28.90 54.00 0.90 1000.50 NW
07/03/2013 06:00 p.m. 27.60 58.00 1.80 1000.70 WNW
07/03/2013 07:00 p.m. 25.40 65.00 1.30 1001.70 WNW
07/03/2013 08:00 p.m. 23.70 71.00 0.40 1002.80 WNW
07/03/2013 09:00 p.m. 22.90 75.00 0.00 1003.50 WNW
07/03/2013 10:00 p.m. 22.40 78.00 0.00 1004.20 WNW
07/03/2013 11:00 p.m. 22.30 79.00 0.00 1004.10 W
08/03/2013 12:00 a.m. 21.80 80.00 0.00 1003.80 W
08/03/2013 01:00 a.m. 22.20 79.00 0.00 1003.40 E
08/03/2013 02:00 a.m. 22.60 81.00 0.00 1002.80 NNE
08/03/2013 03:00 a.m. 21.70 81.00 0.00 1002.20 WNW
08/03/2013 04:00 a.m. 21.00 82.00 0.00 1001.90 WNW
08/03/2013 05:00 a.m. 20.80 81.00 0.00 1002.20 SSW
08/03/2013 06:00 a.m. 21.10 83.00 0.00 1002.60 WNW
08/03/2013 07:00 a.m. 21.20 83.00 0.00 1003.20 WNW
08/03/2013 08:00 a.m. 25.20 73.00 0.90 1003.40 NW
08/03/2013 09:00 a.m. 28.20 59.00 0.90 1003.40 SSW
08/03/2013 10:00 a.m. 29.60 58.00 0.90 1003.30 SSW
08/03/2013 11:00 a.m. 30.10 56.00 1.30 1003.10 SSW
08/03/2013 12:00 p.m. 30.40 54.00 1.30 1003.00 WNW
08/03/2013 01:00 p.m. 31.10 55.00 2.40 1002.90 W
MAXIMO 31.90 85.00 3.10 1005.10
MINIMO 20.80 47.00 0.00 1000.00 NW
PROMEDIO 25.40 69.96 0.71 1002.70

489