ENVIROTEK LABORATORIES, INC.

33 3rd Street, Bordentown, NJ 08505


PHONE 856-478-0010 www.enviroteklab.com
EPA ID # NJ01298 NJ DEP ID # 08012

PROPUR PROONE G2.0 MINERAL TEST REPORT


Report # 15-173-2 Propur ProOne G2.0 Filter
Report Date: 08/10/2015

While there is discussion in the scientific community as to what are good and not so good
minerals as related to drinking water, some familiar minerals considered to be good minerals
include calcium, magnesium and potassium, and not so good to include lead, arsenic, antimony,
aluminum and barium.

Table 1
PROPUR FILTER PROONE G2.0 REDUCTION RESULTS
Test Parameter Influent Water Filter Element ProOne % Reduction
Concentration G2.0 Results

Calcium 185 mg/L 35 mg/L 81.1


Magnesium 18.5 mg/L 19 mg/L 0.0
Potassium 40 mg/L 39 mg/L 2.5

Table 2
PROPUR FILTER PROONE G2.0 REDUCTION RESULTS
Drinking Water Contaminant Tested Influent Water Filter Element ProOne G 2.0 Effluent %
Concentration in g/L Concentration in g/L Reduction
Aluminum 220 4.3 98.0
Antimony 6.2 0.0 100.0
Arsenic (+3 and +5) 310 2.7 99.7
Barium 250 2.5 99.0
Lead 152 0.0 100.0

Jaime Young
Jaime Young
Lab Director

Report #15-173-2, Filter Element ProOne G2.0


Page 1 of 1

The removal/reduction of contaminants or other substances that maybe present in your water supply may vary depending on its
content. The contaminants or other substances removed or reduced are not necessarily present in all users water. Some
contaminants maybe more easily filtered than others. Percentage of reductions will vary over the life of the filter based on the
level of contaminant(s) found in your water supply. Testing was performed under standard laboratory conditions. Actual
performance may vary.